{"lab":{"_id":"69ad52a3de79e566650fb181","accr_number":"AB 245","country":"PL","accr_body":"PCA","address":"WYDZIAŁ CENTRALNE LABORATORIUM BADAŃ TECHNICZNYCH, ul. Giełdowa 7/9, 01-211 Warszawa","categories":["environment","electronics"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":111,"name":"URZĄD KOMUNIKACJI ELEKTRONICZNEJ","parse_status":"parsed","parse_version":3,"pdf_files":["AB_245.pdf"],"scope_summary":"","search_text":"urząd komunikacji elektronicznej wydział centralne laboratorium badań technicznych, ul. giełdowa 7/9, 01-211 warszawa other automotive environment pharma electronics","status":"active","updated_at":"2026-03-08T14:51:06.615Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T15:39:13.058Z","location":{"type":"Point","coordinates":[21.0122,52.2297]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20245,podmiot.html","fields_of_testing":[{"codes":"E/6; E/7; E/14; E/53; E/54","pl":"Badania elektryczne i elektroniczne wyrobów i wyposażenia elektrycznego, oprogramowania, wyposażenia medycznego, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego","en":"Electric and electronic tests of electrical, software, medical equipment, telecommunication products and equipment, electronic products and equipment"},{"codes":"F/6; F/7; F14; F/53; F/54","pl":"Badania kompatybilności elektromagnetycznej wyrobów i wyposażenia elektrycznego, oprogramowania, wyposażenia medycznego, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego","en":"Electromagnetic compatibility (EMC) tests of electrical, software, medical equipment, telecommunication products and equipment, electronic products and equipment"}],"issue":{"no":"24","date":"20.07.2026"},"parse_date":"2026-08-17T15:39:13.058Z","parse_source":"agent-claude-code","map_coord":[52.230315,20.974105],"map_geo":"nominatim-street","lab_locations":[{"name":"Wydział Centralne Laboratorium Badań Technicznych","address":"ul. Giełdowa 7/9, 01-211 Warszawa","city":"Warszawa","postal":"01-211"},{"name":"Wydział Centralne Laboratorium Badań Technicznych","address":"Borucza (Gm. Strachówka) 05-304 Stanisławów","city":"Stanisławów","postal":"05-304"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/ecce81c539b5cb48d9dfb48ea7ada8c2/AB%20245.pdf","has_en":true,"category_counts":{"other":72,"environment":34,"electronics":6},"category_scores":{"other":46.29,"environment":10.32,"electronics":0.32},"has_zh":true},"methods":[{"_id":"6a832b21884ede9a1b2c5434","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy","methodology":"Odchyłka częstotliwości, Frequency error","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odchyłka częstotliwości, Frequency error","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy Odchyłka częstotliwości, Frequency error PN-ETSI EN 300 086 V2.1.2:2017-02 Urzadzenia radiokomunikacyjne ladowej sluzby ruchomej o modulacji kata przeznaczone do transmisji mowy Odchylka czestotliwosci, Frequency error PN-ETSI EN 300 086 V2.1.2:2017-02","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency error","search_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission Frequency error PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission","search_zh":"用于话音传输的角度调制陆地移动业务无线电设备 频率误差 / Frequency error PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_zh":"用于话音传输的角度调制陆地移动业务无线电设备","methodology_zh":"频率误差 / Frequency error"},{"_id":"6a832b21884ede9a1b2c5435","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy","methodology":"Moc nadajnika (sygnał doprowadzony), Transmitter power (conducted)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Moc nadajnika (sygnał doprowadzony), Transmitter power (conducted)","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy Moc nadajnika (sygnał doprowadzony), Transmitter power (conducted) PN-ETSI EN 300 086 V2.1.2:2017-02 Urzadzenia radiokomunikacyjne ladowej sluzby ruchomej o modulacji kata przeznaczone do transmisji mowy Moc nadajnika (sygnal doprowadzony), Transmitter power (conducted) PN-ETSI EN 300 086 V2.1.2:2017-02","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Transmitter power (conducted)","search_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission Transmitter power (conducted) PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission","search_zh":"用于话音传输的角度调制陆地移动业务无线电设备 PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_zh":"用于话音传输的角度调制陆地移动业务无线电设备"},{"_id":"6a832b21884ede9a1b2c5436","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy","methodology":"Maksymalna dopuszczalna dewiacja częstotliwości, Maximum permissible frequency deviation","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Maksymalna dopuszczalna dewiacja częstotliwości, Maximum permissible frequency deviation","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy Maksymalna dopuszczalna dewiacja częstotliwości, Maximum permissible frequency deviation PN-ETSI EN 300 086 V2.1.2:2017-02 Urzadzenia radiokomunikacyjne ladowej sluzby ruchomej o modulacji kata przeznaczone do transmisji mowy Maksymalna dopuszczalna dewiacja czestotliwosci, Maximum permissible frequency deviation PN-ETSI EN 300 086 V2.1.2:2017-02","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission","search_zh":"用于话音传输的角度调制陆地移动业务无线电设备 PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_zh":"用于话音传输的角度调制陆地移动业务无线电设备"},{"_id":"6a832b21884ede9a1b2c5437","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy","methodology":"Działanie nadajnika w przypadku częstotliwości modulujących większych niż 3 kHz, Response of the transmitter to modulation frequencies above 3 kHz","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Działanie nadajnika w przypadku częstotliwości modulujących większych niż 3 kHz, Response of the transmitter to modulation frequencies above 3 kHz","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy Działanie nadajnika w przypadku częstotliwości modulujących większych niż 3 kHz, Response of the transmitter to modulation frequencies above 3 kHz PN-ETSI EN 300 086 V2.1.2:2017-02 Urzadzenia radiokomunikacyjne ladowej sluzby ruchomej o modulacji kata przeznaczone do transmisji mowy Dzialanie nadajnika w przypadku czestotliwosci modulujacych wiekszych niz 3 kHz, Response of the transmitter to modulation frequencies above 3 kHz PN-ETSI EN 300 086 V2.1.2:2017-02","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission","search_zh":"用于话音传输的角度调制陆地移动业务无线电设备 PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_zh":"用于话音传输的角度调制陆地移动业务无线电设备"},{"_id":"6a832b21884ede9a1b2c5438","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy","methodology":"Moc w kanale sąsiednim i kolejnym, Adjacent and alternate channel power","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Moc w kanale sąsiednim i kolejnym, Adjacent and alternate channel power","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy Moc w kanale sąsiednim i kolejnym, Adjacent and alternate channel power PN-ETSI EN 300 086 V2.1.2:2017-02 Urzadzenia radiokomunikacyjne ladowej sluzby ruchomej o modulacji kata przeznaczone do transmisji mowy Moc w kanale sasiednim i kolejnym, Adjacent and alternate channel power PN-ETSI EN 300 086 V2.1.2:2017-02","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission","search_zh":"用于话音传输的角度调制陆地移动业务无线电设备 PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_zh":"用于话音传输的角度调制陆地移动业务无线电设备"},{"_id":"6a832b21884ede9a1b2c5439","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy","methodology":"Emisje uboczne nadajnika, Unwanted emissions in the spurious domain","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisje uboczne nadajnika, Unwanted emissions in the spurious domain","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy Emisje uboczne nadajnika, Unwanted emissions in the spurious domain PN-ETSI EN 300 086 V2.1.2:2017-02 Urzadzenia radiokomunikacyjne ladowej sluzby ruchomej o modulacji kata przeznaczone do transmisji mowy Emisje uboczne nadajnika, Unwanted emissions in the spurious domain PN-ETSI EN 300 086 V2.1.2:2017-02","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission","search_zh":"用于话音传输的角度调制陆地移动业务无线电设备 PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_zh":"用于话音传输的角度调制陆地移动业务无线电设备"},{"_id":"6a832b21884ede9a1b2c543a","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy","methodology":"Tłumienność intermodulacji, Intermodulation attenuation","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Tłumienność intermodulacji, Intermodulation attenuation","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy Tłumienność intermodulacji, Intermodulation attenuation PN-ETSI EN 300 086 V2.1.2:2017-02 Urzadzenia radiokomunikacyjne ladowej sluzby ruchomej o modulacji kata przeznaczone do transmisji mowy Tlumiennosc intermodulacji, Intermodulation attenuation PN-ETSI EN 300 086 V2.1.2:2017-02","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intermodulation attenuation","search_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission Intermodulation attenuation PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission","search_zh":"用于话音传输的角度调制陆地移动业务无线电设备 互调衰减 Intermodulation attenuation PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_zh":"用于话音传输的角度调制陆地移动业务无线电设备","methodology_zh":"互调衰减 Intermodulation attenuation"},{"_id":"6a832b21884ede9a1b2c543b","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy","methodology":"Maksymalna czułość użytkowa (sygnał doprowadzony), Maximum usable sensitivity (conducted)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Maksymalna czułość użytkowa (sygnał doprowadzony), Maximum usable sensitivity (conducted)","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy Maksymalna czułość użytkowa (sygnał doprowadzony), Maximum usable sensitivity (conducted) PN-ETSI EN 300 086 V2.1.2:2017-02 Urzadzenia radiokomunikacyjne ladowej sluzby ruchomej o modulacji kata przeznaczone do transmisji mowy Maksymalna czulosc uzytkowa (sygnal doprowadzony), Maximum usable sensitivity (conducted) PN-ETSI EN 300 086 V2.1.2:2017-02","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission","search_zh":"用于话音传输的角度调制陆地移动业务无线电设备 PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_zh":"用于话音传输的角度调制陆地移动业务无线电设备"},{"_id":"6a832b21884ede9a1b2c543c","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy","methodology":"Selektywność wspólnokanałowa, Co-channel rejection","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Selektywność wspólnokanałowa, Co-channel rejection","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy Selektywność wspólnokanałowa, Co-channel rejection PN-ETSI EN 300 086 V2.1.2:2017-02 Urzadzenia radiokomunikacyjne ladowej sluzby ruchomej o modulacji kata przeznaczone do transmisji mowy Selektywnosc wspolnokanalowa, Co-channel rejection PN-ETSI EN 300 086 V2.1.2:2017-02","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Co-channel rejection","search_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission Co-channel rejection PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission","search_zh":"用于话音传输的角度调制陆地移动业务无线电设备 PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_zh":"用于话音传输的角度调制陆地移动业务无线电设备"},{"_id":"6a832b21884ede9a1b2c543d","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy","methodology":"Selektywność sąsiedniokanałowa, Adjacent channel selectivity","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Selektywność sąsiedniokanałowa, Adjacent channel selectivity","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy Selektywność sąsiedniokanałowa, Adjacent channel selectivity PN-ETSI EN 300 086 V2.1.2:2017-02 Urzadzenia radiokomunikacyjne ladowej sluzby ruchomej o modulacji kata przeznaczone do transmisji mowy Selektywnosc sasiedniokanalowa, Adjacent channel selectivity PN-ETSI EN 300 086 V2.1.2:2017-02","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Adjacent channel selectivity, Adjacent channel selectivity","search_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission Adjacent channel selectivity, Adjacent channel selectivity PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission","search_zh":"用于话音传输的角度调制陆地移动业务无线电设备 邻道选择性 Adjacent channel selectivity PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_zh":"用于话音传输的角度调制陆地移动业务无线电设备","methodology_zh":"邻道选择性 Adjacent channel selectivity"},{"_id":"6a832b21884ede9a1b2c543e","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy","methodology":"Selektywność w stosunku do sygnałów o częstotliwościach niepożądanych, Spurious response rejection","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Selektywność w stosunku do sygnałów o częstotliwościach niepożądanych, Spurious response rejection","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy Selektywność w stosunku do sygnałów o częstotliwościach niepożądanych, Spurious response rejection PN-ETSI EN 300 086 V2.1.2:2017-02 Urzadzenia radiokomunikacyjne ladowej sluzby ruchomej o modulacji kata przeznaczone do transmisji mowy Selektywnosc w stosunku do sygnalow o czestotliwosciach niepozadanych, Spurious response rejection PN-ETSI EN 300 086 V2.1.2:2017-02","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Spurious response rejection","search_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission Spurious response rejection PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission","search_zh":"用于话音传输的角度调制陆地移动业务无线电设备 PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_zh":"用于话音传输的角度调制陆地移动业务无线电设备"},{"_id":"6a832b21884ede9a1b2c543f","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy","methodology":"Odporność na zakłócenia intermodulacyjne, Intermodulation response rejection","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zakłócenia intermodulacyjne, Intermodulation response rejection","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy Odporność na zakłócenia intermodulacyjne, Intermodulation response rejection PN-ETSI EN 300 086 V2.1.2:2017-02 Urzadzenia radiokomunikacyjne ladowej sluzby ruchomej o modulacji kata przeznaczone do transmisji mowy Odpornosc na zaklocenia intermodulacyjne, Intermodulation response rejection PN-ETSI EN 300 086 V2.1.2:2017-02","categories":["other"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intermodulation response rejection","search_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission Intermodulation response rejection PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission","search_zh":"用于话音传输的角度调制陆地移动业务无线电设备 PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_zh":"用于话音传输的角度调制陆地移动业务无线电设备"},{"_id":"6a832b21884ede9a1b2c5440","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy","methodology":"Blokowanie lub pogorszenie czułości, Blocking or desensitization","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Blokowanie lub pogorszenie czułości, Blocking or desensitization","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy Blokowanie lub pogorszenie czułości, Blocking or desensitization PN-ETSI EN 300 086 V2.1.2:2017-02 Urzadzenia radiokomunikacyjne ladowej sluzby ruchomej o modulacji kata przeznaczone do transmisji mowy Blokowanie lub pogorszenie czulosci, Blocking or desensitization PN-ETSI EN 300 086 V2.1.2:2017-02","categories":["other"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Blocking or desensitization","search_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission Blocking or desensitization PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission","search_zh":"用于话音传输的角度调制陆地移动业务无线电设备 PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_zh":"用于话音传输的角度调制陆地移动业务无线电设备"},{"_id":"6a832b21884ede9a1b2c5441","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy","methodology":"Promieniowania uboczne odbiornika, Spurious radiations","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Promieniowania uboczne odbiornika, Spurious radiations","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy Promieniowania uboczne odbiornika, Spurious radiations PN-ETSI EN 300 086 V2.1.2:2017-02 Urzadzenia radiokomunikacyjne ladowej sluzby ruchomej o modulacji kata przeznaczone do transmisji mowy Promieniowania uboczne odbiornika, Spurious radiations PN-ETSI EN 300 086 V2.1.2:2017-02","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Receiver spurious radiations, Spurious radiations","search_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission Receiver spurious radiations, Spurious radiations PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission","search_zh":"用于话音传输的角度调制陆地移动业务无线电设备 接收机杂散辐射 Spurious radiations PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_zh":"用于话音传输的角度调制陆地移动业务无线电设备","methodology_zh":"接收机杂散辐射 Spurious radiations"},{"_id":"6a832b21884ede9a1b2c5442","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy","methodology":"Praca dupleksowa, Duplex operation","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Praca dupleksowa, Duplex operation","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy Praca dupleksowa, Duplex operation PN-ETSI EN 300 086 V2.1.2:2017-02 Urzadzenia radiokomunikacyjne ladowej sluzby ruchomej o modulacji kata przeznaczone do transmisji mowy Praca dupleksowa, Duplex operation PN-ETSI EN 300 086 V2.1.2:2017-02","categories":["other"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission","search_zh":"用于话音传输的角度调制陆地移动业务无线电设备 PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_zh":"用于话音传输的角度调制陆地移动业务无线电设备"},{"_id":"6a832b21884ede9a1b2c5443","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy","methodology":"Utrata czułości odbiornika przy równoczesnym nadawaniu i odbiorze (urządzenie z filtrem dupleksowym), Receiver desensitization (with simultaneous transmission and reception) when equipment operates with a duplex filter","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Utrata czułości odbiornika przy równoczesnym nadawaniu i odbiorze (urządzenie z filtrem dupleksowym), Receiver desensitization (with simultaneous transmission and reception) when equipment operates with a duplex filter","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy Utrata czułości odbiornika przy równoczesnym nadawaniu i odbiorze (urządzenie z filtrem dupleksowym), Receiver desensitization (with simultaneous transmission and reception) when equipment operates with a duplex filter PN-ETSI EN 300 086 V2.1.2:2017-02 Urzadzenia radiokomunikacyjne ladowej sluzby ruchomej o modulacji kata przeznaczone do transmisji mowy Utrata czulosci odbiornika przy rownoczesnym nadawaniu i odbiorze (urzadzenie z filtrem dupleksowym), Receiver desensitization (with simultaneous transmission and reception) when equipment operates with a duplex filter PN-ETSI EN 300 086 V2.1.2:2017-02","categories":["other"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission","search_zh":"用于话音传输的角度调制陆地移动业务无线电设备 PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_zh":"用于话音传输的角度调制陆地移动业务无线电设备"},{"_id":"6a832b21884ede9a1b2c5444","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy","methodology":"Utrata czułości odbiornika przy równoczesnym nadawaniu i odbiorze (urządzenie dwuantenowe), Receiver desensitization (with simultaneous transmission and reception) when equipment operates with two antennas","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Utrata czułości odbiornika przy równoczesnym nadawaniu i odbiorze (urządzenie dwuantenowe), Receiver desensitization (with simultaneous transmission and reception) when equipment operates with two antennas","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiokomunikacyjne lądowej służby ruchomej o modulacji kąta przeznaczone do transmisji mowy Utrata czułości odbiornika przy równoczesnym nadawaniu i odbiorze (urządzenie dwuantenowe), Receiver desensitization (with simultaneous transmission and reception) when equipment operates with two antennas PN-ETSI EN 300 086 V2.1.2:2017-02 Urzadzenia radiokomunikacyjne ladowej sluzby ruchomej o modulacji kata przeznaczone do transmisji mowy Utrata czulosci odbiornika przy rownoczesnym nadawaniu i odbiorze (urzadzenie dwuantenowe), Receiver desensitization (with simultaneous transmission and reception) when equipment operates with two antennas PN-ETSI EN 300 086 V2.1.2:2017-02","categories":["other"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_en":"Land mobile service radiocommunication equipment with angle modulation intended for speech transmission","search_zh":"用于话音传输的角度调制陆地移动业务无线电设备 PN-ETSI EN 300 086 V2.1.2:2017-02","test_object_zh":"用于话音传输的角度调制陆地移动业务无线电设备"},{"_id":"6a832b21884ede9a1b2c5445","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe z dwuwstęgową i/lub jednowstęgową modulacją amplitudy i/lub modulacją kąta dla pasma obywatelskiego","methodology":"Odchyłka częstotliwości, Frequency error","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odchyłka częstotliwości, Frequency error","reference":"PN-ETSI EN 300 433 V2.1.1:2016-11","norm_bases":["PN-ETSI EN 300 433 V2.1.1:2016-11"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe z dwuwstęgową i/lub jednowstęgową modulacją amplitudy i/lub modulacją kąta dla pasma obywatelskiego Odchyłka częstotliwości, Frequency error PN-ETSI EN 300 433 V2.1.1:2016-11 Urzadzenia radiowe z dwuwstegowa i/lub jednowstegowa modulacja amplitudy i/lub modulacja kata dla pasma obywatelskiego Odchylka czestotliwosci, Frequency error PN-ETSI EN 300 433 V2.1.1:2016-11","categories":["other"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency error","search_en":"Radio equipment with double side band and/or single side band amplitude modulation and/or angle modulation for the citizens' band Frequency error PN-ETSI EN 300 433 V2.1.1:2016-11","test_object_en":"Radio equipment with double side band and/or single side band amplitude modulation and/or angle modulation for the citizens' band","search_zh":"民用频段用双边带和/或单边带调幅和/或角度调制无线电设备 频率误差 / Frequency error PN-ETSI EN 300 433 V2.1.1:2016-11","test_object_zh":"民用频段用双边带和/或单边带调幅和/或角度调制无线电设备","methodology_zh":"频率误差 / Frequency error"},{"_id":"6a832b21884ede9a1b2c5446","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe z dwuwstęgową i/lub jednowstęgową modulacją amplitudy i/lub modulacją kąta dla pasma obywatelskiego","methodology":"Moc nadajnika, Transmitter power","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Moc nadajnika, Transmitter power","reference":"PN-ETSI EN 300 433 V2.1.1:2016-11","norm_bases":["PN-ETSI EN 300 433 V2.1.1:2016-11"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe z dwuwstęgową i/lub jednowstęgową modulacją amplitudy i/lub modulacją kąta dla pasma obywatelskiego Moc nadajnika, Transmitter power PN-ETSI EN 300 433 V2.1.1:2016-11 Urzadzenia radiowe z dwuwstegowa i/lub jednowstegowa modulacja amplitudy i/lub modulacja kata dla pasma obywatelskiego Moc nadajnika, Transmitter power PN-ETSI EN 300 433 V2.1.1:2016-11","categories":["other"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Transmitter power","search_en":"Radio equipment with double side band and/or single side band amplitude modulation and/or angle modulation for the citizens' band Transmitter power PN-ETSI EN 300 433 V2.1.1:2016-11","test_object_en":"Radio equipment with double side band and/or single side band amplitude modulation and/or angle modulation for the citizens' band","search_zh":"民用频段用双边带和/或单边带调幅和/或角度调制无线电设备 PN-ETSI EN 300 433 V2.1.1:2016-11","test_object_zh":"民用频段用双边带和/或单边带调幅和/或角度调制无线电设备"},{"_id":"6a832b21884ede9a1b2c5447","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe z dwuwstęgową i/lub jednowstęgową modulacją amplitudy i/lub modulacją kąta dla pasma obywatelskiego","methodology":"Maksymalna dopuszczalna dewiacja częstotliwości, Maximum permissible frequency deviation","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Maksymalna dopuszczalna dewiacja częstotliwości, Maximum permissible frequency deviation","reference":"PN-ETSI EN 300 433 V2.1.1:2016-11","norm_bases":["PN-ETSI EN 300 433 V2.1.1:2016-11"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe z dwuwstęgową i/lub jednowstęgową modulacją amplitudy i/lub modulacją kąta dla pasma obywatelskiego Maksymalna dopuszczalna dewiacja częstotliwości, Maximum permissible frequency deviation PN-ETSI EN 300 433 V2.1.1:2016-11 Urzadzenia radiowe z dwuwstegowa i/lub jednowstegowa modulacja amplitudy i/lub modulacja kata dla pasma obywatelskiego Maksymalna dopuszczalna dewiacja czestotliwosci, Maximum permissible frequency deviation PN-ETSI EN 300 433 V2.1.1:2016-11","categories":["other"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Radio equipment with double side band and/or single side band amplitude modulation and/or angle modulation for the citizens' band PN-ETSI EN 300 433 V2.1.1:2016-11","test_object_en":"Radio equipment with double side band and/or single side band amplitude modulation and/or angle modulation for the citizens' band","search_zh":"民用频段用双边带和/或单边带调幅和/或角度调制无线电设备 PN-ETSI EN 300 433 V2.1.1:2016-11","test_object_zh":"民用频段用双边带和/或单边带调幅和/或角度调制无线电设备"},{"_id":"6a832b21884ede9a1b2c5448","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe z dwuwstęgową i/lub jednowstęgową modulacją amplitudy i/lub modulacją kąta dla pasma obywatelskiego","methodology":"Moc w kanale sąsiednim i kolejnym, Adjacent and alternate channel power","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Moc w kanale sąsiednim i kolejnym, Adjacent and alternate channel power","reference":"PN-ETSI EN 300 433 V2.1.1:2016-11","norm_bases":["PN-ETSI EN 300 433 V2.1.1:2016-11"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe z dwuwstęgową i/lub jednowstęgową modulacją amplitudy i/lub modulacją kąta dla pasma obywatelskiego Moc w kanale sąsiednim i kolejnym, Adjacent and alternate channel power PN-ETSI EN 300 433 V2.1.1:2016-11 Urzadzenia radiowe z dwuwstegowa i/lub jednowstegowa modulacja amplitudy i/lub modulacja kata dla pasma obywatelskiego Moc w kanale sasiednim i kolejnym, Adjacent and alternate channel power PN-ETSI EN 300 433 V2.1.1:2016-11","categories":["other"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Radio equipment with double side band and/or single side band amplitude modulation and/or angle modulation for the citizens' band PN-ETSI EN 300 433 V2.1.1:2016-11","test_object_en":"Radio equipment with double side band and/or single side band amplitude modulation and/or angle modulation for the citizens' band","search_zh":"民用频段用双边带和/或单边带调幅和/或角度调制无线电设备 PN-ETSI EN 300 433 V2.1.1:2016-11","test_object_zh":"民用频段用双边带和/或单边带调幅和/或角度调制无线电设备"},{"_id":"6a832b21884ede9a1b2c5449","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe z dwuwstęgową i/lub jednowstęgową modulacją amplitudy i/lub modulacją kąta dla pasma obywatelskiego","methodology":"Emisje uboczne nadajnika, Unwanted emissions in the spurious domain","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisje uboczne nadajnika, Unwanted emissions in the spurious domain","reference":"PN-ETSI EN 300 433 V2.1.1:2016-11","norm_bases":["PN-ETSI EN 300 433 V2.1.1:2016-11"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe z dwuwstęgową i/lub jednowstęgową modulacją amplitudy i/lub modulacją kąta dla pasma obywatelskiego Emisje uboczne nadajnika, Unwanted emissions in the spurious domain PN-ETSI EN 300 433 V2.1.1:2016-11 Urzadzenia radiowe z dwuwstegowa i/lub jednowstegowa modulacja amplitudy i/lub modulacja kata dla pasma obywatelskiego Emisje uboczne nadajnika, Unwanted emissions in the spurious domain PN-ETSI EN 300 433 V2.1.1:2016-11","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Radio equipment with double side band and/or single side band amplitude modulation and/or angle modulation for the citizens' band PN-ETSI EN 300 433 V2.1.1:2016-11","test_object_en":"Radio equipment with double side band and/or single side band amplitude modulation and/or angle modulation for the citizens' band","search_zh":"民用频段用双边带和/或单边带调幅和/或角度调制无线电设备 PN-ETSI EN 300 433 V2.1.1:2016-11","test_object_zh":"民用频段用双边带和/或单边带调幅和/或角度调制无线电设备"},{"_id":"6a832b21884ede9a1b2c544a","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe z dwuwstęgową i/lub jednowstęgową modulacją amplitudy i/lub modulacją kąta dla pasma obywatelskiego","methodology":"Stany przejściowe nadajnika, Transient behaviour of the transmitter","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stany przejściowe nadajnika, Transient behaviour of the transmitter","reference":"PN-ETSI EN 300 433 V2.1.1:2016-11","norm_bases":["PN-ETSI EN 300 433 V2.1.1:2016-11"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe z dwuwstęgową i/lub jednowstęgową modulacją amplitudy i/lub modulacją kąta dla pasma obywatelskiego Stany przejściowe nadajnika, Transient behaviour of the transmitter PN-ETSI EN 300 433 V2.1.1:2016-11 Urzadzenia radiowe z dwuwstegowa i/lub jednowstegowa modulacja amplitudy i/lub modulacja kata dla pasma obywatelskiego Stany przejsciowe nadajnika, Transient behaviour of the transmitter PN-ETSI EN 300 433 V2.1.1:2016-11","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Radio equipment with double side band and/or single side band amplitude modulation and/or angle modulation for the citizens' band PN-ETSI EN 300 433 V2.1.1:2016-11","test_object_en":"Radio equipment with double side band and/or single side band amplitude modulation and/or angle modulation for the citizens' band","search_zh":"民用频段用双边带和/或单边带调幅和/或角度调制无线电设备 PN-ETSI EN 300 433 V2.1.1:2016-11","test_object_zh":"民用频段用双边带和/或单边带调幅和/或角度调制无线电设备"},{"_id":"6a832b21884ede9a1b2c544b","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe z dwuwstęgową i/lub jednowstęgową modulacją amplitudy i/lub modulacją kąta dla pasma obywatelskiego","methodology":"Maksymalna czułość użytkowa, Maximum usable sensitivity","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Maksymalna czułość użytkowa, Maximum usable sensitivity","reference":"PN-ETSI EN 300 433 V2.1.1:2016-11","norm_bases":["PN-ETSI EN 300 433 V2.1.1:2016-11"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe z dwuwstęgową i/lub jednowstęgową modulacją amplitudy i/lub modulacją kąta dla pasma obywatelskiego Maksymalna czułość użytkowa, Maximum usable sensitivity PN-ETSI EN 300 433 V2.1.1:2016-11 Urzadzenia radiowe z dwuwstegowa i/lub jednowstegowa modulacja amplitudy i/lub modulacja kata dla pasma obywatelskiego Maksymalna czulosc uzytkowa, Maximum usable sensitivity PN-ETSI EN 300 433 V2.1.1:2016-11","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Radio equipment with double side band and/or single side band amplitude modulation and/or angle modulation for the citizens' band PN-ETSI EN 300 433 V2.1.1:2016-11","test_object_en":"Radio equipment with double side band and/or single side band amplitude modulation and/or angle modulation for the citizens' band","search_zh":"民用频段用双边带和/或单边带调幅和/或角度调制无线电设备 PN-ETSI EN 300 433 V2.1.1:2016-11","test_object_zh":"民用频段用双边带和/或单边带调幅和/或角度调制无线电设备"},{"_id":"6a832b21884ede9a1b2c544c","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe z dwuwstęgową i/lub jednowstęgową modulacją amplitudy i/lub modulacją kąta dla pasma obywatelskiego","methodology":"Selektywność sąsiedniokanałowa, Adjacent channel selectivity","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Selektywność sąsiedniokanałowa, Adjacent channel selectivity","reference":"PN-ETSI EN 300 433 V2.1.1:2016-11","norm_bases":["PN-ETSI EN 300 433 V2.1.1:2016-11"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe z dwuwstęgową i/lub jednowstęgową modulacją amplitudy i/lub modulacją kąta dla pasma obywatelskiego Selektywność sąsiedniokanałowa, Adjacent channel selectivity PN-ETSI EN 300 433 V2.1.1:2016-11 Urzadzenia radiowe z dwuwstegowa i/lub jednowstegowa modulacja amplitudy i/lub modulacja kata dla pasma obywatelskiego Selektywnosc sasiedniokanalowa, Adjacent channel selectivity PN-ETSI EN 300 433 V2.1.1:2016-11","categories":["other"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Adjacent channel selectivity, Adjacent channel selectivity","search_en":"Radio equipment with double side band and/or single side band amplitude modulation and/or angle modulation for the citizens' band Adjacent channel selectivity, Adjacent channel selectivity PN-ETSI EN 300 433 V2.1.1:2016-11","test_object_en":"Radio equipment with double side band and/or single side band amplitude modulation and/or angle modulation for the citizens' band","search_zh":"民用频段用双边带和/或单边带调幅和/或角度调制无线电设备 邻道选择性 Adjacent channel selectivity PN-ETSI EN 300 433 V2.1.1:2016-11","test_object_zh":"民用频段用双边带和/或单边带调幅和/或角度调制无线电设备","methodology_zh":"邻道选择性 Adjacent channel selectivity"},{"_id":"6a832b21884ede9a1b2c544d","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe z dwuwstęgową i/lub jednowstęgową modulacją amplitudy i/lub modulacją kąta dla pasma obywatelskiego","methodology":"Tłumienie intermodulacji odbiornika, Intermodulation response rejection","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Tłumienie intermodulacji odbiornika, Intermodulation response rejection","reference":"PN-ETSI EN 300 433 V2.1.1:2016-11","norm_bases":["PN-ETSI EN 300 433 V2.1.1:2016-11"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe z dwuwstęgową i/lub jednowstęgową modulacją amplitudy i/lub modulacją kąta dla pasma obywatelskiego Tłumienie intermodulacji odbiornika, Intermodulation response rejection PN-ETSI EN 300 433 V2.1.1:2016-11 Urzadzenia radiowe z dwuwstegowa i/lub jednowstegowa modulacja amplitudy i/lub modulacja kata dla pasma obywatelskiego Tlumienie intermodulacji odbiornika, Intermodulation response rejection PN-ETSI EN 300 433 V2.1.1:2016-11","categories":["other"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intermodulation response rejection","search_en":"Radio equipment with double side band and/or single side band amplitude modulation and/or angle modulation for the citizens' band Intermodulation response rejection PN-ETSI EN 300 433 V2.1.1:2016-11","test_object_en":"Radio equipment with double side band and/or single side band amplitude modulation and/or angle modulation for the citizens' band","search_zh":"民用频段用双边带和/或单边带调幅和/或角度调制无线电设备 PN-ETSI EN 300 433 V2.1.1:2016-11","test_object_zh":"民用频段用双边带和/或单边带调幅和/或角度调制无线电设备"},{"_id":"6a832b21884ede9a1b2c544e","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe z dwuwstęgową i/lub jednowstęgową modulacją amplitudy i/lub modulacją kąta dla pasma obywatelskiego","methodology":"Promieniowania uboczne odbiornika, Spurious radiations","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Promieniowania uboczne odbiornika, Spurious radiations","reference":"PN-ETSI EN 300 433 V2.1.1:2016-11","norm_bases":["PN-ETSI EN 300 433 V2.1.1:2016-11"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe z dwuwstęgową i/lub jednowstęgową modulacją amplitudy i/lub modulacją kąta dla pasma obywatelskiego Promieniowania uboczne odbiornika, Spurious radiations PN-ETSI EN 300 433 V2.1.1:2016-11 Urzadzenia radiowe z dwuwstegowa i/lub jednowstegowa modulacja amplitudy i/lub modulacja kata dla pasma obywatelskiego Promieniowania uboczne odbiornika, Spurious radiations PN-ETSI EN 300 433 V2.1.1:2016-11","categories":["other"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Receiver spurious radiations, Spurious radiations","search_en":"Radio equipment with double side band and/or single side band amplitude modulation and/or angle modulation for the citizens' band Receiver spurious radiations, Spurious radiations PN-ETSI EN 300 433 V2.1.1:2016-11","test_object_en":"Radio equipment with double side band and/or single side band amplitude modulation and/or angle modulation for the citizens' band","search_zh":"民用频段用双边带和/或单边带调幅和/或角度调制无线电设备 接收机杂散辐射 Spurious radiations PN-ETSI EN 300 433 V2.1.1:2016-11","test_object_zh":"民用频段用双边带和/或单边带调幅和/或角度调制无线电设备","methodology_zh":"接收机杂散辐射 Spurious radiations"},{"_id":"6a832b21884ede9a1b2c544f","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe do transmisji danych i mowy","methodology":"Odchyłka częstotliwości, Frequency error","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odchyłka częstotliwości, Frequency error","reference":"PN-ETSI EN 300 113 V2.2.1:2017-07","norm_bases":["PN-ETSI EN 300 113 V2.2.1:2017-07"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe do transmisji danych i mowy Odchyłka częstotliwości, Frequency error PN-ETSI EN 300 113 V2.2.1:2017-07 Urzadzenia radiowe do transmisji danych i mowy Odchylka czestotliwosci, Frequency error PN-ETSI EN 300 113 V2.2.1:2017-07","categories":["other"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency error","search_en":"Radio equipment for data and voice transmission Frequency error PN-ETSI EN 300 113 V2.2.1:2017-07","test_object_en":"Radio equipment for data and voice transmission","methodology_zh":"频率误差 / Frequency error","search_zh":"数据与话音传输用无线电设备 频率误差 / Frequency error PN-ETSI EN 300 113 V2.2.1:2017-07","test_object_zh":"数据与话音传输用无线电设备"},{"_id":"6a832b21884ede9a1b2c5450","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe do transmisji danych i mowy","methodology":"Moc nadajnika (sygnał doprowadzony), Transmitter power (conducted)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Moc nadajnika (sygnał doprowadzony), Transmitter power (conducted)","reference":"PN-ETSI EN 300 113 V2.2.1:2017-07","norm_bases":["PN-ETSI EN 300 113 V2.2.1:2017-07"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe do transmisji danych i mowy Moc nadajnika (sygnał doprowadzony), Transmitter power (conducted) PN-ETSI EN 300 113 V2.2.1:2017-07 Urzadzenia radiowe do transmisji danych i mowy Moc nadajnika (sygnal doprowadzony), Transmitter power (conducted) PN-ETSI EN 300 113 V2.2.1:2017-07","categories":["other"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Transmitter power (conducted)","search_en":"Radio equipment for data and voice transmission Transmitter power (conducted) PN-ETSI EN 300 113 V2.2.1:2017-07","test_object_en":"Radio equipment for data and voice transmission","search_zh":"数据与话音传输用无线电设备 PN-ETSI EN 300 113 V2.2.1:2017-07","test_object_zh":"数据与话音传输用无线电设备"},{"_id":"6a832b21884ede9a1b2c5451","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe do transmisji danych i mowy","methodology":"Moc w kanale sąsiednim i kolejnym, Adjacent and alternate channel power","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Moc w kanale sąsiednim i kolejnym, Adjacent and alternate channel power","reference":"PN-ETSI EN 300 113 V2.2.1:2017-07","norm_bases":["PN-ETSI EN 300 113 V2.2.1:2017-07"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe do transmisji danych i mowy Moc w kanale sąsiednim i kolejnym, Adjacent and alternate channel power PN-ETSI EN 300 113 V2.2.1:2017-07 Urzadzenia radiowe do transmisji danych i mowy Moc w kanale sasiednim i kolejnym, Adjacent and alternate channel power PN-ETSI EN 300 113 V2.2.1:2017-07","categories":["other"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Radio equipment for data and voice transmission PN-ETSI EN 300 113 V2.2.1:2017-07","test_object_en":"Radio equipment for data and voice transmission","search_zh":"数据与话音传输用无线电设备 PN-ETSI EN 300 113 V2.2.1:2017-07","test_object_zh":"数据与话音传输用无线电设备"},{"_id":"6a832b21884ede9a1b2c5452","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe do transmisji danych i mowy","methodology":"Emisje uboczne nadajnika, Unwanted emissions in the spurious domain","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisje uboczne nadajnika, Unwanted emissions in the spurious domain","reference":"PN-ETSI EN 300 113 V2.2.1:2017-07","norm_bases":["PN-ETSI EN 300 113 V2.2.1:2017-07"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe do transmisji danych i mowy Emisje uboczne nadajnika, Unwanted emissions in the spurious domain PN-ETSI EN 300 113 V2.2.1:2017-07 Urzadzenia radiowe do transmisji danych i mowy Emisje uboczne nadajnika, Unwanted emissions in the spurious domain PN-ETSI EN 300 113 V2.2.1:2017-07","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Radio equipment for data and voice transmission PN-ETSI EN 300 113 V2.2.1:2017-07","test_object_en":"Radio equipment for data and voice transmission","search_zh":"数据与话音传输用无线电设备 PN-ETSI EN 300 113 V2.2.1:2017-07","test_object_zh":"数据与话音传输用无线电设备"},{"_id":"6a832b21884ede9a1b2c5453","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe do transmisji danych i mowy","methodology":"Tłumienność intermodulacji, Intermodulation attenuation","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Tłumienność intermodulacji, Intermodulation attenuation","reference":"PN-ETSI EN 300 113 V2.2.1:2017-07","norm_bases":["PN-ETSI EN 300 113 V2.2.1:2017-07"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe do transmisji danych i mowy Tłumienność intermodulacji, Intermodulation attenuation PN-ETSI EN 300 113 V2.2.1:2017-07 Urzadzenia radiowe do transmisji danych i mowy Tlumiennosc intermodulacji, Intermodulation attenuation PN-ETSI EN 300 113 V2.2.1:2017-07","categories":["other"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intermodulation attenuation","search_en":"Radio equipment for data and voice transmission Intermodulation attenuation PN-ETSI EN 300 113 V2.2.1:2017-07","test_object_en":"Radio equipment for data and voice transmission","search_zh":"数据与话音传输用无线电设备 互调衰减 Intermodulation attenuation PN-ETSI EN 300 113 V2.2.1:2017-07","test_object_zh":"数据与话音传输用无线电设备","methodology_zh":"互调衰减 Intermodulation attenuation"},{"_id":"6a832b21884ede9a1b2c5454","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe do transmisji danych i mowy","methodology":"Promieniowania uboczne odbiornika, Spurious radiations","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Promieniowania uboczne odbiornika, Spurious radiations","reference":"PN-ETSI EN 300 113 V2.2.1:2017-07","norm_bases":["PN-ETSI EN 300 113 V2.2.1:2017-07"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe do transmisji danych i mowy Promieniowania uboczne odbiornika, Spurious radiations PN-ETSI EN 300 113 V2.2.1:2017-07 Urzadzenia radiowe do transmisji danych i mowy Promieniowania uboczne odbiornika, Spurious radiations PN-ETSI EN 300 113 V2.2.1:2017-07","categories":["other"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Receiver spurious radiations, Spurious radiations","search_en":"Radio equipment for data and voice transmission Receiver spurious radiations, Spurious radiations PN-ETSI EN 300 113 V2.2.1:2017-07","test_object_en":"Radio equipment for data and voice transmission","search_zh":"数据与话音传输用无线电设备 接收机杂散辐射 Spurious radiations PN-ETSI EN 300 113 V2.2.1:2017-07","test_object_zh":"数据与话音传输用无线电设备","methodology_zh":"接收机杂散辐射 Spurious radiations"},{"_id":"6a832b21884ede9a1b2c5455","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe emitujące sygnały uruchamiające specyficzne działania odbiorników","methodology":"Odchyłka częstotliwości, Frequency error","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odchyłka częstotliwości, Frequency error","reference":"PN-ETSI EN 300 219 V2.1.1:2017-02","norm_bases":["PN-ETSI EN 300 219 V2.1.1:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe emitujące sygnały uruchamiające specyficzne działania odbiorników Odchyłka częstotliwości, Frequency error PN-ETSI EN 300 219 V2.1.1:2017-02 Urzadzenia radiowe emitujace sygnaly uruchamiajace specyficzne dzialania odbiornikow Odchylka czestotliwosci, Frequency error PN-ETSI EN 300 219 V2.1.1:2017-02","categories":["other"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency error","search_en":"Radio equipment emitting signals triggering specific actions of receivers Frequency error PN-ETSI EN 300 219 V2.1.1:2017-02","test_object_en":"Radio equipment emitting signals triggering specific actions of receivers","search_zh":"发射触发接收装置特定动作信号的无线电设备 频率误差 / Frequency error PN-ETSI EN 300 219 V2.1.1:2017-02","test_object_zh":"发射触发接收装置特定动作信号的无线电设备","methodology_zh":"频率误差 / Frequency error"},{"_id":"6a832b21884ede9a1b2c5456","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe emitujące sygnały uruchamiające specyficzne działania odbiorników","methodology":"Moc fali nośnej (sygnał doprowadzony), Carrier power (conducted)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Moc fali nośnej (sygnał doprowadzony), Carrier power (conducted)","reference":"PN-ETSI EN 300 219 V2.1.1:2017-02","norm_bases":["PN-ETSI EN 300 219 V2.1.1:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe emitujące sygnały uruchamiające specyficzne działania odbiorników Moc fali nośnej (sygnał doprowadzony), Carrier power (conducted) PN-ETSI EN 300 219 V2.1.1:2017-02 Urzadzenia radiowe emitujace sygnaly uruchamiajace specyficzne dzialania odbiornikow Moc fali nosnej (sygnal doprowadzony), Carrier power (conducted) PN-ETSI EN 300 219 V2.1.1:2017-02","categories":["other"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carrier power (conducted)","search_en":"Radio equipment emitting signals triggering specific actions of receivers Carrier power (conducted) PN-ETSI EN 300 219 V2.1.1:2017-02","test_object_en":"Radio equipment emitting signals triggering specific actions of receivers","search_zh":"发射触发接收装置特定动作信号的无线电设备 PN-ETSI EN 300 219 V2.1.1:2017-02","test_object_zh":"发射触发接收装置特定动作信号的无线电设备"},{"_id":"6a832b21884ede9a1b2c5457","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe emitujące sygnały uruchamiające specyficzne działania odbiorników","methodology":"Moc w kanale sąsiednim i kolejnym, Adjacent and alternate channel power","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Moc w kanale sąsiednim i kolejnym, Adjacent and alternate channel power","reference":"PN-ETSI EN 300 219 V2.1.1:2017-02","norm_bases":["PN-ETSI EN 300 219 V2.1.1:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe emitujące sygnały uruchamiające specyficzne działania odbiorników Moc w kanale sąsiednim i kolejnym, Adjacent and alternate channel power PN-ETSI EN 300 219 V2.1.1:2017-02 Urzadzenia radiowe emitujace sygnaly uruchamiajace specyficzne dzialania odbiornikow Moc w kanale sasiednim i kolejnym, Adjacent and alternate channel power PN-ETSI EN 300 219 V2.1.1:2017-02","categories":["other"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Radio equipment emitting signals triggering specific actions of receivers PN-ETSI EN 300 219 V2.1.1:2017-02","test_object_en":"Radio equipment emitting signals triggering specific actions of receivers","search_zh":"发射触发接收装置特定动作信号的无线电设备 PN-ETSI EN 300 219 V2.1.1:2017-02","test_object_zh":"发射触发接收装置特定动作信号的无线电设备"},{"_id":"6a832b21884ede9a1b2c5458","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe emitujące sygnały uruchamiające specyficzne działania odbiorników","methodology":"Promieniowania niepożądane nadajnika, Transmitter spurious emissions","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Promieniowania niepożądane nadajnika, Transmitter spurious emissions","reference":"PN-ETSI EN 300 219 V2.1.1:2017-02","norm_bases":["PN-ETSI EN 300 219 V2.1.1:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe emitujące sygnały uruchamiające specyficzne działania odbiorników Promieniowania niepożądane nadajnika, Transmitter spurious emissions PN-ETSI EN 300 219 V2.1.1:2017-02 Urzadzenia radiowe emitujace sygnaly uruchamiajace specyficzne dzialania odbiornikow Promieniowania niepozadane nadajnika, Transmitter spurious emissions PN-ETSI EN 300 219 V2.1.1:2017-02","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Transmitter spurious emissions","search_en":"Radio equipment emitting signals triggering specific actions of receivers Transmitter spurious emissions PN-ETSI EN 300 219 V2.1.1:2017-02","test_object_en":"Radio equipment emitting signals triggering specific actions of receivers","search_zh":"发射触发接收装置特定动作信号的无线电设备 PN-ETSI EN 300 219 V2.1.1:2017-02","test_object_zh":"发射触发接收装置特定动作信号的无线电设备"},{"_id":"6a832b21884ede9a1b2c5459","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe emitujące sygnały uruchamiające specyficzne działania odbiorników","methodology":"Tłumienność intermodulacji, Intermodulation attenuation","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Tłumienność intermodulacji, Intermodulation attenuation","reference":"PN-ETSI EN 300 219 V2.1.1:2017-02","norm_bases":["PN-ETSI EN 300 219 V2.1.1:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe emitujące sygnały uruchamiające specyficzne działania odbiorników Tłumienność intermodulacji, Intermodulation attenuation PN-ETSI EN 300 219 V2.1.1:2017-02 Urzadzenia radiowe emitujace sygnaly uruchamiajace specyficzne dzialania odbiornikow Tlumiennosc intermodulacji, Intermodulation attenuation PN-ETSI EN 300 219 V2.1.1:2017-02","categories":["other"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intermodulation attenuation","search_en":"Radio equipment emitting signals triggering specific actions of receivers Intermodulation attenuation PN-ETSI EN 300 219 V2.1.1:2017-02","test_object_en":"Radio equipment emitting signals triggering specific actions of receivers","search_zh":"发射触发接收装置特定动作信号的无线电设备 互调衰减 Intermodulation attenuation PN-ETSI EN 300 219 V2.1.1:2017-02","test_object_zh":"发射触发接收装置特定动作信号的无线电设备","methodology_zh":"互调衰减 Intermodulation attenuation"},{"_id":"6a832b21884ede9a1b2c545a","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe emitujące sygnały uruchamiające specyficzne działania odbiorników","methodology":"Stany przejściowe częstotliwości nadajnika, Transient frequency behaviour of the transmitter","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stany przejściowe częstotliwości nadajnika, Transient frequency behaviour of the transmitter","reference":"PN-ETSI EN 300 219 V2.1.1:2017-02","norm_bases":["PN-ETSI EN 300 219 V2.1.1:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe emitujące sygnały uruchamiające specyficzne działania odbiorników Stany przejściowe częstotliwości nadajnika, Transient frequency behaviour of the transmitter PN-ETSI EN 300 219 V2.1.1:2017-02 Urzadzenia radiowe emitujace sygnaly uruchamiajace specyficzne dzialania odbiornikow Stany przejsciowe czestotliwosci nadajnika, Transient frequency behaviour of the transmitter PN-ETSI EN 300 219 V2.1.1:2017-02","categories":["other"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Radio equipment emitting signals triggering specific actions of receivers PN-ETSI EN 300 219 V2.1.1:2017-02","test_object_en":"Radio equipment emitting signals triggering specific actions of receivers","search_zh":"发射触发接收装置特定动作信号的无线电设备 PN-ETSI EN 300 219 V2.1.1:2017-02","test_object_zh":"发射触发接收装置特定动作信号的无线电设备"},{"_id":"6a832b21884ede9a1b2c545b","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe emitujące sygnały uruchamiające specyficzne działania odbiorników","methodology":"Promieniowania niepożądane odbiornika, Receiver spurious radiations","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Promieniowania niepożądane odbiornika, Receiver spurious radiations","reference":"PN-ETSI EN 300 219 V2.1.1:2017-02","norm_bases":["PN-ETSI EN 300 219 V2.1.1:2017-02"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe emitujące sygnały uruchamiające specyficzne działania odbiorników Promieniowania niepożądane odbiornika, Receiver spurious radiations PN-ETSI EN 300 219 V2.1.1:2017-02 Urzadzenia radiowe emitujace sygnaly uruchamiajace specyficzne dzialania odbiornikow Promieniowania niepozadane odbiornika, Receiver spurious radiations PN-ETSI EN 300 219 V2.1.1:2017-02","categories":["other"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Receiver spurious radiations","search_en":"Radio equipment emitting signals triggering specific actions of receivers Receiver spurious radiations PN-ETSI EN 300 219 V2.1.1:2017-02","test_object_en":"Radio equipment emitting signals triggering specific actions of receivers","search_zh":"发射触发接收装置特定动作信号的无线电设备 PN-ETSI EN 300 219 V2.1.1:2017-02","test_object_zh":"发射触发接收装置特定动作信号的无线电设备"},{"_id":"6a832b21884ede9a1b2c545c","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu z poziomami mocy do 500 mW (z gniazdem antenowym)","methodology":"Odchyłka częstotliwości, Frequency error","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odchyłka częstotliwości, Frequency error","reference":"PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","norm_bases":["PN-ETSI EN 300 220-1 V3.1.1:2017-08","PN-ETSI EN 300 220-2 V3.1.1:2017-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu z poziomami mocy do 500 mW (z gniazdem antenowym) Odchyłka częstotliwości, Frequency error PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08 Urzadzenia radiowe bliskiego zasiegu z poziomami mocy do 500 mW (z gniazdem antenowym) Odchylka czestotliwosci, Frequency error PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","categories":["other"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency error","search_en":"Short range radio devices with power levels up to 500 mW (with antenna socket) Frequency error PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_en":"Short range radio devices with power levels up to 500 mW (with antenna socket)","methodology_zh":"频率误差 / Frequency error","search_zh":"功率电平至 500 mW 的短距离无线电设备（带天线接口） 频率误差 / Frequency error PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_zh":"功率电平至 500 mW 的短距离无线电设备（带天线接口）"},{"_id":"6a832b21884ede9a1b2c545d","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu z poziomami mocy do 500 mW (z gniazdem antenowym)","methodology":"Równoważna moc promieniowana, Effective radiated power","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważna moc promieniowana, Effective radiated power","reference":"PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","norm_bases":["PN-ETSI EN 300 220-1 V3.1.1:2017-08","PN-ETSI EN 300 220-2 V3.1.1:2017-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu z poziomami mocy do 500 mW (z gniazdem antenowym) Równoważna moc promieniowana, Effective radiated power PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08 Urzadzenia radiowe bliskiego zasiegu z poziomami mocy do 500 mW (z gniazdem antenowym) Rownowazna moc promieniowana, Effective radiated power PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","categories":["other"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective radiated power, Effective radiated power","search_en":"Short range radio devices with power levels up to 500 mW (with antenna socket) Effective radiated power, Effective radiated power PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_en":"Short range radio devices with power levels up to 500 mW (with antenna socket)","search_zh":"功率电平至 500 mW 的短距离无线电设备（带天线接口） PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_zh":"功率电平至 500 mW 的短距离无线电设备（带天线接口）"},{"_id":"6a832b21884ede9a1b2c545e","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu z poziomami mocy do 500 mW (z gniazdem antenowym)","methodology":"Moc w kanale sąsiednim, Adjacent channel power","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Moc w kanale sąsiednim, Adjacent channel power","reference":"PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","norm_bases":["PN-ETSI EN 300 220-1 V3.1.1:2017-08","PN-ETSI EN 300 220-2 V3.1.1:2017-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu z poziomami mocy do 500 mW (z gniazdem antenowym) Moc w kanale sąsiednim, Adjacent channel power PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08 Urzadzenia radiowe bliskiego zasiegu z poziomami mocy do 500 mW (z gniazdem antenowym) Moc w kanale sasiednim, Adjacent channel power PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","categories":["other"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Adjacent channel power","search_en":"Short range radio devices with power levels up to 500 mW (with antenna socket) Adjacent channel power PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_en":"Short range radio devices with power levels up to 500 mW (with antenna socket)","search_zh":"功率电平至 500 mW 的短距离无线电设备（带天线接口） PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_zh":"功率电平至 500 mW 的短距离无线电设备（带天线接口）"},{"_id":"6a832b21884ede9a1b2c545f","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu z poziomami mocy do 500 mW (z gniazdem antenowym)","methodology":"Szerokość zajmowanego pasma, Occupied bandwidth","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Szerokość zajmowanego pasma, Occupied bandwidth","reference":"PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","norm_bases":["PN-ETSI EN 300 220-1 V3.1.1:2017-08","PN-ETSI EN 300 220-2 V3.1.1:2017-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu z poziomami mocy do 500 mW (z gniazdem antenowym) Szerokość zajmowanego pasma, Occupied bandwidth PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08 Urzadzenia radiowe bliskiego zasiegu z poziomami mocy do 500 mW (z gniazdem antenowym) Szerokosc zajmowanego pasma, Occupied bandwidth PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","categories":["other"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Occupied bandwidth, Occupied bandwidth","search_en":"Short range radio devices with power levels up to 500 mW (with antenna socket) Occupied bandwidth, Occupied bandwidth PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_en":"Short range radio devices with power levels up to 500 mW (with antenna socket)","search_zh":"功率电平至 500 mW 的短距离无线电设备（带天线接口） PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_zh":"功率电平至 500 mW 的短距离无线电设备（带天线接口）"},{"_id":"6a832b21884ede9a1b2c5460","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu z poziomami mocy do 500 mW (z gniazdem antenowym)","methodology":"Emisje niepożądane, Unwanted emissions in the spurious domain","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisje niepożądane, Unwanted emissions in the spurious domain","reference":"PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","norm_bases":["PN-ETSI EN 300 220-1 V3.1.1:2017-08","PN-ETSI EN 300 220-2 V3.1.1:2017-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu z poziomami mocy do 500 mW (z gniazdem antenowym) Emisje niepożądane, Unwanted emissions in the spurious domain PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08 Urzadzenia radiowe bliskiego zasiegu z poziomami mocy do 500 mW (z gniazdem antenowym) Emisje niepozadane, Unwanted emissions in the spurious domain PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","categories":["environment"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Short range radio devices with power levels up to 500 mW (with antenna socket) PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_en":"Short range radio devices with power levels up to 500 mW (with antenna socket)","search_zh":"功率电平至 500 mW 的短距离无线电设备（带天线接口） PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_zh":"功率电平至 500 mW 的短距离无线电设备（带天线接口）"},{"_id":"6a832b21884ede9a1b2c5461","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu z poziomami mocy do 500 mW (z gniazdem antenowym)","methodology":"Emisje pozapasmowe nadajnika, Tx Out of Band emissions","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisje pozapasmowe nadajnika, Tx Out of Band emissions","reference":"PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","norm_bases":["PN-ETSI EN 300 220-1 V3.1.1:2017-08","PN-ETSI EN 300 220-2 V3.1.1:2017-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu z poziomami mocy do 500 mW (z gniazdem antenowym) Emisje pozapasmowe nadajnika, Tx Out of Band emissions PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08 Urzadzenia radiowe bliskiego zasiegu z poziomami mocy do 500 mW (z gniazdem antenowym) Emisje pozapasmowe nadajnika, Tx Out of Band emissions PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","categories":["environment"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Short range radio devices with power levels up to 500 mW (with antenna socket) PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_en":"Short range radio devices with power levels up to 500 mW (with antenna socket)","search_zh":"功率电平至 500 mW 的短距离无线电设备（带天线接口） PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_zh":"功率电平至 500 mW 的短距离无线电设备（带天线接口）"},{"_id":"6a832b21884ede9a1b2c5462","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia przemysłowe, naukowe i medyczne (ISM)","methodology":"Emisja zaburzeń przewodzonych, Conducted emission","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń przewodzonych, Conducted emission","reference":"PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1 :2017-06 | PN-EN 55011:2016-05/A11 :2020-07 | PN-EN 55011:2016-05/A2 :2021-08","norm_bases":["PN-EN 55011:2016-05","PN-EN 55011:2016-05/A1 :2017-06","PN-EN 55011:2016-05/A11 :2020-07","PN-EN 55011:2016-05/A2 :2021-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia przemysłowe, naukowe i medyczne (ISM) Emisja zaburzeń przewodzonych, Conducted emission PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1 :2017-06 | PN-EN 55011:2016-05/A11 :2020-07 | PN-EN 55011:2016-05/A2 :2021-08 Urzadzenia przemyslowe, naukowe i medyczne (ISM) Emisja zaburzen przewodzonych, Conducted emission PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1 :2017-06 | PN-EN 55011:2016-05/A11 :2020-07 | PN-EN 55011:2016-05/A2 :2021-08","categories":["environment"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Conducted disturbance emission, Conducted emission","search_en":"Industrial, scientific and medical equipment (ISM) Conducted disturbance emission, Conducted emission PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1 :2017-06 | PN-EN 55011:2016-05/A11 :2020-07 | PN-EN 55011:2016-05/A2 :2021-08","test_object_en":"Industrial, scientific and medical equipment (ISM)","methodology_zh":"传导骚扰发射 / Conducted emission","search_zh":"工业、科学与医疗（ISM）设备 传导骚扰发射 / Conducted emission PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1 :2017-06 | PN-EN 55011:2016-05/A11 :2020-07 | PN-EN 55011:2016-05/A2 :2021-08","test_object_zh":"工业、科学与医疗（ISM）设备"},{"_id":"6a832b21884ede9a1b2c5463","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia","methodology":"Emisja zaburzeń przewodzonych, Conducted emission","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń przewodzonych, Conducted emission","reference":"PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020","norm_bases":["PN-EN 55014-1:2017-06","PN-EN 55014-1:2017-06/A11:2020"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia Emisja zaburzeń przewodzonych, Conducted emission PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020 Przyrzady powszechnego uzytku, narzedzia elektryczne i podobne urzadzenia Emisja zaburzen przewodzonych, Conducted emission PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020","categories":["environment"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Conducted disturbance emission, Conducted emission","search_en":"Household appliances, electric tools and similar apparatus Conducted disturbance emission, Conducted emission PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020","test_object_en":"Household appliances, electric tools and similar apparatus","search_zh":"家用器具、电动工具及类似设备 传导骚扰发射 / Conducted emission PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020","test_object_zh":"家用器具、电动工具及类似设备","methodology_zh":"传导骚扰发射 / Conducted emission"},{"_id":"6a832b21884ede9a1b2c5464","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Elektryczne urządzenia oświetleniowe i urządzenia podobne","methodology":"Emisja zaburzeń przewodzonych, Conducted emission","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń przewodzonych, Conducted emission","reference":"PN-EN 55015:2013-10 | PN-EN 55015:2013-1/A1:2015-08 | PN-EN 55015:2019-11 | PN-EN 55015:2019-11/A11:2020-07","norm_bases":["PN-EN 55015:2013-10","PN-EN 55015:2013-1/A1:2015-08","PN-EN 55015:2019-11","PN-EN 55015:2019-11/A11:2020-07"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczne urządzenia oświetleniowe i urządzenia podobne Emisja zaburzeń przewodzonych, Conducted emission PN-EN 55015:2013-10 | PN-EN 55015:2013-1/A1:2015-08 | PN-EN 55015:2019-11 | PN-EN 55015:2019-11/A11:2020-07 Elektryczne urzadzenia oswietleniowe i urzadzenia podobne Emisja zaburzen przewodzonych, Conducted emission PN-EN 55015:2013-10 | PN-EN 55015:2013-1/A1:2015-08 | PN-EN 55015:2019-11 | PN-EN 55015:2019-11/A11:2020-07","categories":["environment"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Conducted disturbance emission, Conducted emission","search_en":"Electrical lighting and similar equipment Conducted disturbance emission, Conducted emission PN-EN 55015:2013-10 | PN-EN 55015:2013-1/A1:2015-08 | PN-EN 55015:2019-11 | PN-EN 55015:2019-11/A11:2020-07","test_object_en":"Electrical lighting and similar equipment","search_zh":"电气照明设备及类似设备 传导骚扰发射 / Conducted emission PN-EN 55015:2013-10 | PN-EN 55015:2013-1/A1:2015-08 | PN-EN 55015:2019-11 | PN-EN 55015:2019-11/A11:2020-07","test_object_zh":"电气照明设备及类似设备","methodology_zh":"传导骚扰发射 / Conducted emission"},{"_id":"6a832b21884ede9a1b2c5465","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia informatyczne","methodology":"Emisja zaburzeń przewodzonych, Conducted emission","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń przewodzonych, Conducted emission","reference":"PN-EN 55022:2011 | PN-EN 55022:2011/AC:2011","norm_bases":["PN-EN 55022:2011","PN-EN 55022:2011/AC:2011"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia informatyczne Emisja zaburzeń przewodzonych, Conducted emission PN-EN 55022:2011 | PN-EN 55022:2011/AC:2011 Urzadzenia informatyczne Emisja zaburzen przewodzonych, Conducted emission PN-EN 55022:2011 | PN-EN 55022:2011/AC:2011","categories":["environment"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Conducted disturbance emission, Conducted emission","search_en":"Information technology equipment Conducted disturbance emission, Conducted emission PN-EN 55022:2011 | PN-EN 55022:2011/AC:2011","test_object_en":"Information technology equipment","search_zh":"信息技术设备 传导骚扰发射 / Conducted emission PN-EN 55022:2011 | PN-EN 55022:2011/AC:2011","test_object_zh":"信息技术设备","methodology_zh":"传导骚扰发射 / Conducted emission"},{"_id":"6a832b21884ede9a1b2c5466","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia multimedialne","methodology":"Emisja zaburzeń przewodzonych, Conducted emission","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń przewodzonych, Conducted emission","reference":"PN-EN 55032:2012 | PN-EN 55032:2012/AC :2013 | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","norm_bases":["PN-EN 55032:2012","PN-EN 55032:2012/AC :2013","PN-EN 55032:2015-09","PN-EN 55032:2015-09/A11:2020-07","PN-EN 55032:2015-09/A1:2021-05"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia multimedialne Emisja zaburzeń przewodzonych, Conducted emission PN-EN 55032:2012 | PN-EN 55032:2012/AC :2013 | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05 Urzadzenia multimedialne Emisja zaburzen przewodzonych, Conducted emission PN-EN 55032:2012 | PN-EN 55032:2012/AC :2013 | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","categories":["environment"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Conducted disturbance emission, Conducted emission","search_en":"Multimedia equipment Conducted disturbance emission, Conducted emission PN-EN 55032:2012 | PN-EN 55032:2012/AC :2013 | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","test_object_en":"Multimedia equipment","search_zh":"多媒体设备 传导骚扰发射 / Conducted emission PN-EN 55032:2012 | PN-EN 55032:2012/AC :2013 | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","test_object_zh":"多媒体设备","methodology_zh":"传导骚扰发射 / Conducted emission"},{"_id":"6a832b21884ede9a1b2c5467","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Elektryczne i elektroniczne urządzenia gospodarstwa domowego i urządzenia biurowe","methodology":"Pobór mocy w stanie gotowości do pracy, Power consumption in standby mode","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobór mocy w stanie gotowości do pracy, Power consumption in standby mode","reference":"PN-EN 50564:2011","norm_bases":["PN-EN 50564:2011"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczne i elektroniczne urządzenia gospodarstwa domowego i urządzenia biurowe Pobór mocy w stanie gotowości do pracy, Power consumption in standby mode PN-EN 50564:2011 Elektryczne i elektroniczne urzadzenia gospodarstwa domowego i urzadzenia biurowe Pobor mocy w stanie gotowosci do pracy, Power consumption in standby mode PN-EN 50564:2011","categories":["electronics"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Power consumption in standby mode, Power consumption in standby mode","search_en":"Electrical and electronic household appliances and office equipment Power consumption in standby mode, Power consumption in standby mode PN-EN 50564:2011","test_object_en":"Electrical and electronic household appliances and office equipment"},{"_id":"6a832b21884ede9a1b2c5468","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Zewnętrzne zasilacze a.c. - d.c. i a.c. - a.c","methodology":"Pobór mocy bez obciążenia i średnia sprawność w stanie obciążenia, No-load power and average efficiency of active mode","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobór mocy bez obciążenia i średnia sprawność w stanie obciążenia, No-load power and average efficiency of active mode","reference":"PN-EN 50563:2012 | PN-EN 50563:2012/A1:2014-07","norm_bases":["PN-EN 50563:2012","PN-EN 50563:2012/A1:2014-07"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zewnętrzne zasilacze a.c. - d.c. i a.c. - a.c Pobór mocy bez obciążenia i średnia sprawność w stanie obciążenia, No-load power and average efficiency of active mode PN-EN 50563:2012 | PN-EN 50563:2012/A1:2014-07 Zewnetrzne zasilacze a.c. - d.c. i a.c. - a.c Pobor mocy bez obciazenia i srednia sprawnosc w stanie obciazenia, No-load power and average efficiency of active mode PN-EN 50563:2012 | PN-EN 50563:2012/A1:2014-07","categories":["other"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a832b21884ede9a1b2c5469","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Telewizory, monitory telewizyjne","methodology":"Pobór mocy w stanie gotowości do pracy, Power consumption in standby mode","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobór mocy w stanie gotowości do pracy, Power consumption in standby mode","reference":"PN-EN 62301:2006 | PN-EN 50564:2011","norm_bases":["PN-EN 62301:2006","PN-EN 50564:2011"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Telewizory, monitory telewizyjne Pobór mocy w stanie gotowości do pracy, Power consumption in standby mode PN-EN 62301:2006 | PN-EN 50564:2011 Telewizory, monitory telewizyjne Pobor mocy w stanie gotowosci do pracy, Power consumption in standby mode PN-EN 62301:2006 | PN-EN 50564:2011","categories":["other"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Power consumption in standby mode, Power consumption in standby mode","search_en":"Television sets, television monitors Power consumption in standby mode, Power consumption in standby mode PN-EN 62301:2006 | PN-EN 50564:2011","test_object_en":"Television sets, television monitors"},{"_id":"6a832b21884ede9a1b2c546a","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Telewizory, monitory telewizyjne","methodology":"Zużycie energii w trybie włączenia, Power consumption in ON mode","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zużycie energii w trybie włączenia, Power consumption in ON mode","reference":"PN-EN 62087:2010 | PN-EN 62087:2012","norm_bases":["PN-EN 62087:2010","PN-EN 62087:2012"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Telewizory, monitory telewizyjne Zużycie energii w trybie włączenia, Power consumption in ON mode PN-EN 62087:2010 | PN-EN 62087:2012 Telewizory, monitory telewizyjne Zuzycie energii w trybie wlaczenia, Power consumption in ON mode PN-EN 62087:2010 | PN-EN 62087:2012","categories":["other"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Power consumption in ON mode","search_en":"Television sets, television monitors Power consumption in ON mode PN-EN 62087:2010 | PN-EN 62087:2012","test_object_en":"Television sets, television monitors"},{"_id":"6a832b21884ede9a1b2c546b","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia przemysłowe, naukowe i medyczne (ISM)","methodology":"Emisja zaburzeń przewodzonych, Conducted Emission","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń przewodzonych, Conducted Emission","reference":"PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","norm_bases":["PN-EN 55011:2016-05","PN-EN 55011:2016-05/A1:2017-06","PN-EN 55011:2016-05/A11:2020-07","PN-EN 55011:2016-05/A2:2021-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia przemysłowe, naukowe i medyczne (ISM) Emisja zaburzeń przewodzonych, Conducted Emission PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08 Urzadzenia przemyslowe, naukowe i medyczne (ISM) Emisja zaburzen przewodzonych, Conducted Emission PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","categories":["environment"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Conducted disturbance emission, Conducted Emission","search_en":"Industrial, scientific and medical equipment (ISM) Conducted disturbance emission, Conducted Emission PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","test_object_en":"Industrial, scientific and medical equipment (ISM)","methodology_zh":"传导骚扰发射 / Conducted Emission","search_zh":"工业、科学与医疗（ISM）设备 传导骚扰发射 / Conducted Emission PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","test_object_zh":"工业、科学与医疗（ISM）设备"},{"_id":"6a832b21884ede9a1b2c546c","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia","methodology":"Emisja zaburzeń przewodzonych, Conducted Emission","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń przewodzonych, Conducted Emission","reference":"PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020-07","norm_bases":["PN-EN 55014-1:2017-06","PN-EN 55014-1:2017-06/A11:2020-07"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia Emisja zaburzeń przewodzonych, Conducted Emission PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020-07 Przyrzady powszechnego uzytku, narzedzia elektryczne i podobne urzadzenia Emisja zaburzen przewodzonych, Conducted Emission PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020-07","categories":["environment"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Conducted disturbance emission, Conducted Emission","search_en":"Household appliances, electric tools and similar apparatus Conducted disturbance emission, Conducted Emission PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020-07","test_object_en":"Household appliances, electric tools and similar apparatus","search_zh":"家用器具、电动工具及类似设备 传导骚扰发射 / Conducted Emission PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020-07","test_object_zh":"家用器具、电动工具及类似设备","methodology_zh":"传导骚扰发射 / Conducted Emission"},{"_id":"6a832b21884ede9a1b2c546d","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Elektryczne urządzenia oświetleniowe i urządzenia podobne","methodology":"Emisja zaburzeń przewodzonych, Conducted Emission","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń przewodzonych, Conducted Emission","reference":"PN-EN 55015:2013-10 | PN-EN 55015:2013-1/A1:2015-08 | PN-EN 55015:2019-11 | PN-EN 55015:2019-11/A11:2020-07","norm_bases":["PN-EN 55015:2013-10","PN-EN 55015:2013-1/A1:2015-08","PN-EN 55015:2019-11","PN-EN 55015:2019-11/A11:2020-07"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczne urządzenia oświetleniowe i urządzenia podobne Emisja zaburzeń przewodzonych, Conducted Emission PN-EN 55015:2013-10 | PN-EN 55015:2013-1/A1:2015-08 | PN-EN 55015:2019-11 | PN-EN 55015:2019-11/A11:2020-07 Elektryczne urzadzenia oswietleniowe i urzadzenia podobne Emisja zaburzen przewodzonych, Conducted Emission PN-EN 55015:2013-10 | PN-EN 55015:2013-1/A1:2015-08 | PN-EN 55015:2019-11 | PN-EN 55015:2019-11/A11:2020-07","categories":["environment"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Conducted disturbance emission, Conducted Emission","search_en":"Electrical lighting and similar equipment Conducted disturbance emission, Conducted Emission PN-EN 55015:2013-10 | PN-EN 55015:2013-1/A1:2015-08 | PN-EN 55015:2019-11 | PN-EN 55015:2019-11/A11:2020-07","test_object_en":"Electrical lighting and similar equipment","search_zh":"电气照明设备及类似设备 传导骚扰发射 / Conducted Emission PN-EN 55015:2013-10 | PN-EN 55015:2013-1/A1:2015-08 | PN-EN 55015:2019-11 | PN-EN 55015:2019-11/A11:2020-07","test_object_zh":"电气照明设备及类似设备","methodology_zh":"传导骚扰发射 / Conducted Emission"},{"_id":"6a832b21884ede9a1b2c546e","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia informatyczne","methodology":"Emisja zaburzeń przewodzonych, Conducted Emission","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń przewodzonych, Conducted Emission","reference":"PN-EN 55022:2011 | PN-EN 55022:2011/AC:2011","norm_bases":["PN-EN 55022:2011","PN-EN 55022:2011/AC:2011"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia informatyczne Emisja zaburzeń przewodzonych, Conducted Emission PN-EN 55022:2011 | PN-EN 55022:2011/AC:2011 Urzadzenia informatyczne Emisja zaburzen przewodzonych, Conducted Emission PN-EN 55022:2011 | PN-EN 55022:2011/AC:2011","categories":["environment"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Conducted disturbance emission, Conducted Emission","search_en":"Information technology equipment Conducted disturbance emission, Conducted Emission PN-EN 55022:2011 | PN-EN 55022:2011/AC:2011","test_object_en":"Information technology equipment","search_zh":"信息技术设备 传导骚扰发射 / Conducted Emission PN-EN 55022:2011 | PN-EN 55022:2011/AC:2011","test_object_zh":"信息技术设备","methodology_zh":"传导骚扰发射 / Conducted Emission"},{"_id":"6a832b21884ede9a1b2c546f","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia multimedialne","methodology":"Emisja zaburzeń przewodzonych, Conducted Emission","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń przewodzonych, Conducted Emission","reference":"PN-EN 55032:2012 | PN-EN 55032:2012/AC :2013 | PN-EN 55032 :2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-09","norm_bases":["PN-EN 55032:2012","PN-EN 55032:2012/AC :2013","PN-EN 55032 :2015-09","PN-EN 55032:2015-09/A11:2020-07","PN-EN 55032:2015-09/A1:2021-09"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia multimedialne Emisja zaburzeń przewodzonych, Conducted Emission PN-EN 55032:2012 | PN-EN 55032:2012/AC :2013 | PN-EN 55032 :2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-09 Urzadzenia multimedialne Emisja zaburzen przewodzonych, Conducted Emission PN-EN 55032:2012 | PN-EN 55032:2012/AC :2013 | PN-EN 55032 :2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-09","categories":["environment"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Conducted disturbance emission, Conducted Emission","search_en":"Multimedia equipment Conducted disturbance emission, Conducted Emission PN-EN 55032:2012 | PN-EN 55032:2012/AC :2013 | PN-EN 55032 :2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-09","test_object_en":"Multimedia equipment","search_zh":"多媒体设备 传导骚扰发射 / Conducted Emission PN-EN 55032:2012 | PN-EN 55032:2012/AC :2013 | PN-EN 55032 :2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-09","test_object_zh":"多媒体设备","methodology_zh":"传导骚扰发射 / Conducted Emission"},{"_id":"6a832b21884ede9a1b2c5470","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia","methodology":"Moc zaburzeń, Disturbance power","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Moc zaburzeń, Disturbance power","reference":"PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020-07","norm_bases":["PN-EN 55014-1:2017-06","PN-EN 55014-1:2017-06/A11:2020-07"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia Moc zaburzeń, Disturbance power PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020-07 Przyrzady powszechnego uzytku, narzedzia elektryczne i podobne urzadzenia Moc zaburzen, Disturbance power PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020-07","categories":["other"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Disturbance power","search_en":"Household appliances, electric tools and similar apparatus Disturbance power PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020-07","test_object_en":"Household appliances, electric tools and similar apparatus","search_zh":"家用器具、电动工具及类似设备 PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020-07","test_object_zh":"家用器具、电动工具及类似设备"},{"_id":"6a832b21884ede9a1b2c5471","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Elektryczne urządzenia oświetleniowe i urządzenia podobne","methodology":"Natężenie pola magnetycznego, Magnetic field strange","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego, Magnetic field strange","reference":"PN-EN 55015:2013-10 | PN-EN 55015:2013-10/A1:2015-08","norm_bases":["PN-EN 55015:2013-10","PN-EN 55015:2013-10/A1:2015-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczne urządzenia oświetleniowe i urządzenia podobne Natężenie pola magnetycznego, Magnetic field strange PN-EN 55015:2013-10 | PN-EN 55015:2013-10/A1:2015-08 Elektryczne urzadzenia oswietleniowe i urzadzenia podobne Natezenie pola magnetycznego, Magnetic field strange PN-EN 55015:2013-10 | PN-EN 55015:2013-10/A1:2015-08","categories":["other"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength","search_en":"Electrical lighting and similar equipment Magnetic field strength PN-EN 55015:2013-10 | PN-EN 55015:2013-10/A1:2015-08","test_object_en":"Electrical lighting and similar equipment","search_zh":"电气照明设备及类似设备 PN-EN 55015:2013-10 | PN-EN 55015:2013-10/A1:2015-08","test_object_zh":"电气照明设备及类似设备"},{"_id":"6a832b21884ede9a1b2c5472","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia","methodology":"Natężenie pola magnetycznego, Magnetic field strange","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego, Magnetic field strange","reference":"PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020-07","norm_bases":["PN-EN 55014-1:2017-06","PN-EN 55014-1:2017-06/A11:2020-07"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia Natężenie pola magnetycznego, Magnetic field strange PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020-07 Przyrzady powszechnego uzytku, narzedzia elektryczne i podobne urzadzenia Natezenie pola magnetycznego, Magnetic field strange PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020-07","categories":["other"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength","search_en":"Household appliances, electric tools and similar apparatus Magnetic field strength PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020-07","test_object_en":"Household appliances, electric tools and similar apparatus","search_zh":"家用器具、电动工具及类似设备 PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020-07","test_object_zh":"家用器具、电动工具及类似设备"},{"_id":"6a832b21884ede9a1b2c5473","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia przemysłowe, naukowe i medyczne (ISM)","methodology":"Emisja zaburzeń promieniowanych, Radiated Emission","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń promieniowanych, Radiated Emission","reference":"PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","norm_bases":["PN-EN 55011:2016-05","PN-EN 55011:2016-05/A1:2017-06","PN-EN 55011:2016-05/A11:2020-07","PN-EN 55011:2016-05/A2:2021-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia przemysłowe, naukowe i medyczne (ISM) Emisja zaburzeń promieniowanych, Radiated Emission PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08 Urzadzenia przemyslowe, naukowe i medyczne (ISM) Emisja zaburzen promieniowanych, Radiated Emission PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","categories":["environment"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Radiated disturbance emission, Radiated Emission","search_en":"Industrial, scientific and medical equipment (ISM) Radiated disturbance emission, Radiated Emission PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","test_object_en":"Industrial, scientific and medical equipment (ISM)","methodology_zh":"辐射骚扰发射 / Radiated Emission","search_zh":"工业、科学与医疗（ISM）设备 辐射骚扰发射 / Radiated Emission PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","test_object_zh":"工业、科学与医疗（ISM）设备"},{"_id":"6a832b21884ede9a1b2c5474","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia","methodology":"Emisja zaburzeń promieniowanych, Radiated Emission","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń promieniowanych, Radiated Emission","reference":"PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020-07","norm_bases":["PN-EN 55014-1:2017-06","PN-EN 55014-1:2017-06/A11:2020-07"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia Emisja zaburzeń promieniowanych, Radiated Emission PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020-07 Przyrzady powszechnego uzytku, narzedzia elektryczne i podobne urzadzenia Emisja zaburzen promieniowanych, Radiated Emission PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020-07","categories":["environment"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Radiated disturbance emission, Radiated Emission","search_en":"Household appliances, electric tools and similar apparatus Radiated disturbance emission, Radiated Emission PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020-07","test_object_en":"Household appliances, electric tools and similar apparatus","search_zh":"家用器具、电动工具及类似设备 辐射骚扰发射 / Radiated Emission PN-EN 55014-1:2017-06 | PN-EN 55014-1:2017-06/A11:2020-07","test_object_zh":"家用器具、电动工具及类似设备","methodology_zh":"辐射骚扰发射 / Radiated Emission"},{"_id":"6a832b21884ede9a1b2c5475","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Elektryczne urządzenia oświetleniowe i urządzenia podobne","methodology":"Emisja zaburzeń promieniowanych, Radiated Emission","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń promieniowanych, Radiated Emission","reference":"PN-EN 55015:2013-10 | PN-EN 55015:2013-10/A1:2015-08","norm_bases":["PN-EN 55015:2013-10","PN-EN 55015:2013-10/A1:2015-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczne urządzenia oświetleniowe i urządzenia podobne Emisja zaburzeń promieniowanych, Radiated Emission PN-EN 55015:2013-10 | PN-EN 55015:2013-10/A1:2015-08 Elektryczne urzadzenia oswietleniowe i urzadzenia podobne Emisja zaburzen promieniowanych, Radiated Emission PN-EN 55015:2013-10 | PN-EN 55015:2013-10/A1:2015-08","categories":["environment"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Radiated disturbance emission, Radiated Emission","search_en":"Electrical lighting and similar equipment Radiated disturbance emission, Radiated Emission PN-EN 55015:2013-10 | PN-EN 55015:2013-10/A1:2015-08","test_object_en":"Electrical lighting and similar equipment","search_zh":"电气照明设备及类似设备 辐射骚扰发射 / Radiated Emission PN-EN 55015:2013-10 | PN-EN 55015:2013-10/A1:2015-08","test_object_zh":"电气照明设备及类似设备","methodology_zh":"辐射骚扰发射 / Radiated Emission"},{"_id":"6a832b21884ede9a1b2c5476","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia informatyczne","methodology":"Emisja zaburzeń promieniowanych, Radiated Emission","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń promieniowanych, Radiated Emission","reference":"PN-EN 55022:2011 | PN-EN 55022:2011/AC:2011","norm_bases":["PN-EN 55022:2011","PN-EN 55022:2011/AC:2011"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia informatyczne Emisja zaburzeń promieniowanych, Radiated Emission PN-EN 55022:2011 | PN-EN 55022:2011/AC:2011 Urzadzenia informatyczne Emisja zaburzen promieniowanych, Radiated Emission PN-EN 55022:2011 | PN-EN 55022:2011/AC:2011","categories":["environment"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Radiated disturbance emission, Radiated Emission","search_en":"Information technology equipment Radiated disturbance emission, Radiated Emission PN-EN 55022:2011 | PN-EN 55022:2011/AC:2011","test_object_en":"Information technology equipment","search_zh":"信息技术设备 辐射骚扰发射 / Radiated Emission PN-EN 55022:2011 | PN-EN 55022:2011/AC:2011","test_object_zh":"信息技术设备","methodology_zh":"辐射骚扰发射 / Radiated Emission"},{"_id":"6a832b21884ede9a1b2c5477","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia multimedialne","methodology":"Emisja zaburzeń promieniowanych, Radiated Emission","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń promieniowanych, Radiated Emission","reference":"PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","norm_bases":["PN-EN 55032:2015-09","PN-EN 55032:2015-09/A11:2020-07","PN-EN 55032:2015-09/A1:2021-05"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia multimedialne Emisja zaburzeń promieniowanych, Radiated Emission PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05 Urzadzenia multimedialne Emisja zaburzen promieniowanych, Radiated Emission PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","categories":["environment"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Radiated disturbance emission, Radiated Emission","search_en":"Multimedia equipment Radiated disturbance emission, Radiated Emission PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","test_object_en":"Multimedia equipment","search_zh":"多媒体设备 辐射骚扰发射 / Radiated Emission PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","test_object_zh":"多媒体设备","methodology_zh":"辐射骚扰发射 / Radiated Emission"},{"_id":"6a832b21884ede9a1b2c5478","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","methodology":"Emisja harmonicznych prądu, Harmonic current emissions","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja harmonicznych prądu, Harmonic current emissions","reference":"PN-EN 61000-3-2:2014-10 | PN-EN 61000-3-2:2019-04 | PN-EN 61000-3-2:2019-04/A1:2021-08 | PN-EN IEC 61000-3-2:2019-04/A2:2024-12","norm_bases":["PN-EN 61000-3-2:2014-10","PN-EN 61000-3-2:2019-04","PN-EN 61000-3-2:2019-04/A1:2021-08","PN-EN IEC 61000-3-2:2019-04/A2:2024-12"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne i elektroniczne Emisja harmonicznych prądu, Harmonic current emissions PN-EN 61000-3-2:2014-10 | PN-EN 61000-3-2:2019-04 | PN-EN 61000-3-2:2019-04/A1:2021-08 | PN-EN IEC 61000-3-2:2019-04/A2:2024-12 Urzadzenia elektryczne i elektroniczne Emisja harmonicznych pradu, Harmonic current emissions PN-EN 61000-3-2:2014-10 | PN-EN 61000-3-2:2019-04 | PN-EN 61000-3-2:2019-04/A1:2021-08 | PN-EN IEC 61000-3-2:2019-04/A2:2024-12","categories":["environment","electronics"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Harmonic current emissions","search_en":"Electrical and electronic equipment Harmonic current emissions PN-EN 61000-3-2:2014-10 | PN-EN 61000-3-2:2019-04 | PN-EN 61000-3-2:2019-04/A1:2021-08 | PN-EN IEC 61000-3-2:2019-04/A2:2024-12","test_object_en":"Electrical and electronic equipment","search_zh":"电气与电子设备 PN-EN 61000-3-2:2014-10 | PN-EN 61000-3-2:2019-04 | PN-EN 61000-3-2:2019-04/A1:2021-08 | PN-EN IEC 61000-3-2:2019-04/A2:2024-12","test_object_zh":"电气与电子设备"},{"_id":"6a832b21884ede9a1b2c5479","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","methodology":"Wahania napięcia i migotanie światła, Flicker","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wahania napięcia i migotanie światła, Flicker","reference":"PN-EN 61000-3-3 :2009 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04","norm_bases":["PN-EN 61000-3-3 :2009","PN-EN 61000-3-3:2013-10","PN-EN 61000-3-3:2013-10/A1:2019-10","PN-EN 61000-3-3:2013-10/A2:2022-04"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne i elektroniczne Wahania napięcia i migotanie światła, Flicker PN-EN 61000-3-3 :2009 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04 Urzadzenia elektryczne i elektroniczne Wahania napiecia i migotanie swiatla, Flicker PN-EN 61000-3-3 :2009 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04","categories":["electronics"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Voltage fluctuations and light flicker, Flicker","search_en":"Electrical and electronic equipment Voltage fluctuations and light flicker, Flicker PN-EN 61000-3-3 :2009 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04","test_object_en":"Electrical and electronic equipment","search_zh":"电气与电子设备 PN-EN 61000-3-3 :2009 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04","test_object_zh":"电气与电子设备"},{"_id":"6a832b21884ede9a1b2c547a","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","methodology":"Odporność na wyładowania elektrostatyczne ESD","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na wyładowania elektrostatyczne ESD","reference":"PN-EN 61000-4-2:1999 | PN-EN 61000-4-2:1999/A2:2003 | PN-EN 61000-4-2:2011","norm_bases":["PN-EN 61000-4-2:1999","PN-EN 61000-4-2:1999/A2:2003","PN-EN 61000-4-2:2011"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne i elektroniczne Odporność na wyładowania elektrostatyczne ESD PN-EN 61000-4-2:1999 | PN-EN 61000-4-2:1999/A2:2003 | PN-EN 61000-4-2:2011 Urzadzenia elektryczne i elektroniczne Odpornosc na wyladowania elektrostatyczne ESD PN-EN 61000-4-2:1999 | PN-EN 61000-4-2:1999/A2:2003 | PN-EN 61000-4-2:2011","categories":["electronics"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Electrical and electronic equipment PN-EN 61000-4-2:1999 | PN-EN 61000-4-2:1999/A2:2003 | PN-EN 61000-4-2:2011","test_object_en":"Electrical and electronic equipment","search_zh":"电气与电子设备 PN-EN 61000-4-2:1999 | PN-EN 61000-4-2:1999/A2:2003 | PN-EN 61000-4-2:2011","test_object_zh":"电气与电子设备"},{"_id":"6a832b21884ede9a1b2c547b","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","methodology":"Odporność na pole elektromagnetyczne o częstotliwości radiowej, Electromagnetic field immunity","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na pole elektromagnetyczne o częstotliwości radiowej, Electromagnetic field immunity","reference":"PN-EN 61000-4-3:2007 | PN-EN 61000-4-3:2007/A1:2008 | PN-EN 61000-4-3:2007/A2:2011","norm_bases":["PN-EN 61000-4-3:2007","PN-EN 61000-4-3:2007/A1:2008","PN-EN 61000-4-3:2007/A2:2011"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne i elektroniczne Odporność na pole elektromagnetyczne o częstotliwości radiowej, Electromagnetic field immunity PN-EN 61000-4-3:2007 | PN-EN 61000-4-3:2007/A1:2008 | PN-EN 61000-4-3:2007/A2:2011 Urzadzenia elektryczne i elektroniczne Odpornosc na pole elektromagnetyczne o czestotliwosci radiowej, Electromagnetic field immunity PN-EN 61000-4-3:2007 | PN-EN 61000-4-3:2007/A1:2008 | PN-EN 61000-4-3:2007/A2:2011","categories":["electronics"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Radio frequency electromagnetic field immunity","search_en":"Electrical and electronic equipment Radio frequency electromagnetic field immunity PN-EN 61000-4-3:2007 | PN-EN 61000-4-3:2007/A1:2008 | PN-EN 61000-4-3:2007/A2:2011","test_object_en":"Electrical and electronic equipment","search_zh":"电气与电子设备 PN-EN 61000-4-3:2007 | PN-EN 61000-4-3:2007/A1:2008 | PN-EN 61000-4-3:2007/A2:2011","test_object_zh":"电气与电子设备"},{"_id":"6a832b21884ede9a1b2c547c","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne","methodology":"Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej, Immunity to conducted disturbances, induced by radio-frequency fields","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej, Immunity to conducted disturbances, induced by radio-frequency fields","reference":"PN-EN 61000-4-6:2009 | PN-EN 61000-4-6:2014-04","norm_bases":["PN-EN 61000-4-6:2009","PN-EN 61000-4-6:2014-04"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne i elektroniczne Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej, Immunity to conducted disturbances, induced by radio-frequency fields PN-EN 61000-4-6:2009 | PN-EN 61000-4-6:2014-04 Urzadzenia elektryczne i elektroniczne Odpornosc na zaburzenia przewodzone, indukowane przez pola o czestotliwosci radiowej, Immunity to conducted disturbances, induced by radio-frequency fields PN-EN 61000-4-6:2009 | PN-EN 61000-4-6:2014-04","categories":["electronics"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Electrical and electronic equipment PN-EN 61000-4-6:2009 | PN-EN 61000-4-6:2014-04","test_object_en":"Electrical and electronic equipment","search_zh":"电气与电子设备 PN-EN 61000-4-6:2009 | PN-EN 61000-4-6:2014-04","test_object_zh":"电气与电子设备"},{"_id":"6a832b21884ede9a1b2c547d","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Elektryczne przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia","methodology":"Odporność elektromagnetyczna - bez odporności na pole magnetyczne o częstotliwości sieci energetycznej oraz bez odporności na zapady napięcia, krótkie przerwy i zmiany napięcia, Electromagnetic immunity – without power frequency magnetic field immunity and voltage dips, short interruptions and voltage variations immunity","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność elektromagnetyczna - bez odporności na pole magnetyczne o częstotliwości sieci energetycznej oraz bez odporności na zapady napięcia, krótkie przerwy i zmiany napięcia, Electromagnetic immunity – without power frequency magnetic field immunity and voltage dips, short interruptions and voltage variations immunity","reference":"PN-EN 55014-2:1999 | PN-EN 55014-2:1999/A1:2004 | PN-EN 55014-2:1999/A2:2009 | PN-EN 55014-2:2015-06","norm_bases":["PN-EN 55014-2:1999","PN-EN 55014-2:1999/A1:2004","PN-EN 55014-2:1999/A2:2009","PN-EN 55014-2:2015-06"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczne przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia Odporność elektromagnetyczna - bez odporności na pole magnetyczne o częstotliwości sieci energetycznej oraz bez odporności na zapady napięcia, krótkie przerwy i zmiany napięcia, Electromagnetic immunity – without power frequency magnetic field immunity and voltage dips, short interruptions and voltage variations immunity PN-EN 55014-2:1999 | PN-EN 55014-2:1999/A1:2004 | PN-EN 55014-2:1999/A2:2009 | PN-EN 55014-2:2015-06 Elektryczne przyrzady powszechnego uzytku, narzedzia elektryczne i podobne urzadzenia Odpornosc elektromagnetyczna - bez odpornosci na pole magnetyczne o czestotliwosci sieci energetycznej oraz bez odpornosci na zapady napiecia, krotkie przerwy i zmiany napiecia, Electromagnetic immunity – without power frequency magnetic field immunity and voltage dips, short interruptions and voltage variations immunity PN-EN 55014-2:1999 | PN-EN 55014-2:1999/A1:2004 | PN-EN 55014-2:1999/A2:2009 | PN-EN 55014-2:2015-06","categories":["other"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Electrical household appliances, electric tools and similar apparatus PN-EN 55014-2:1999 | PN-EN 55014-2:1999/A1:2004 | PN-EN 55014-2:1999/A2:2009 | PN-EN 55014-2:2015-06","test_object_en":"Electrical household appliances, electric tools and similar apparatus"},{"_id":"6a832b21884ede9a1b2c547e","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia informatyczne","methodology":"Odporność elektromagnetyczna - bez odporności na pole magnetyczne o częstotliwości sieci energetycznej oraz bez odporności na zapady napięcia, krótkie przerwy i zmiany napięcia, Electromagnetic immunity – without power frequency magnetic field immunity and voltage dips, short interruptions and voltage variations immunity","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność elektromagnetyczna - bez odporności na pole magnetyczne o częstotliwości sieci energetycznej oraz bez odporności na zapady napięcia, krótkie przerwy i zmiany napięcia, Electromagnetic immunity – without power frequency magnetic field immunity and voltage dips, short interruptions and voltage variations immunity","reference":"PN-EN 55024:2011 | PN-EN 55024:2011/A1:2015-08","norm_bases":["PN-EN 55024:2011","PN-EN 55024:2011/A1:2015-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia informatyczne Odporność elektromagnetyczna - bez odporności na pole magnetyczne o częstotliwości sieci energetycznej oraz bez odporności na zapady napięcia, krótkie przerwy i zmiany napięcia, Electromagnetic immunity – without power frequency magnetic field immunity and voltage dips, short interruptions and voltage variations immunity PN-EN 55024:2011 | PN-EN 55024:2011/A1:2015-08 Urzadzenia informatyczne Odpornosc elektromagnetyczna - bez odpornosci na pole magnetyczne o czestotliwosci sieci energetycznej oraz bez odpornosci na zapady napiecia, krotkie przerwy i zmiany napiecia, Electromagnetic immunity – without power frequency magnetic field immunity and voltage dips, short interruptions and voltage variations immunity PN-EN 55024:2011 | PN-EN 55024:2011/A1:2015-08","categories":["other"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Information technology equipment PN-EN 55024:2011 | PN-EN 55024:2011/A1:2015-08","test_object_en":"Information technology equipment","search_zh":"信息技术设备 PN-EN 55024:2011 | PN-EN 55024:2011/A1:2015-08","test_object_zh":"信息技术设备"},{"_id":"6a832b21884ede9a1b2c547f","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia multimedialne","methodology":"Odporność elektromagnetyczna - bez odporności na pole magnetyczne o częstotliwości sieci energetycznej oraz bez odporności na zapady napięcia, krótkie przerwy i zmiany napięcia, Electromagnetic immunity – without power frequency magnetic field immunity and voltage dips, short interruptions and voltage variations immunity","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność elektromagnetyczna - bez odporności na pole magnetyczne o częstotliwości sieci energetycznej oraz bez odporności na zapady napięcia, krótkie przerwy i zmiany napięcia, Electromagnetic immunity – without power frequency magnetic field immunity and voltage dips, short interruptions and voltage variations immunity","reference":"PN-EN 55035:2017-09 | PN-EN 55035:2017-09/A11:2020-09","norm_bases":["PN-EN 55035:2017-09","PN-EN 55035:2017-09/A11:2020-09"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia multimedialne Odporność elektromagnetyczna - bez odporności na pole magnetyczne o częstotliwości sieci energetycznej oraz bez odporności na zapady napięcia, krótkie przerwy i zmiany napięcia, Electromagnetic immunity – without power frequency magnetic field immunity and voltage dips, short interruptions and voltage variations immunity PN-EN 55035:2017-09 | PN-EN 55035:2017-09/A11:2020-09 Urzadzenia multimedialne Odpornosc elektromagnetyczna - bez odpornosci na pole magnetyczne o czestotliwosci sieci energetycznej oraz bez odpornosci na zapady napiecia, krotkie przerwy i zmiany napiecia, Electromagnetic immunity – without power frequency magnetic field immunity and voltage dips, short interruptions and voltage variations immunity PN-EN 55035:2017-09 | PN-EN 55035:2017-09/A11:2020-09","categories":["other"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Multimedia equipment PN-EN 55035:2017-09 | PN-EN 55035:2017-09/A11:2020-09","test_object_en":"Multimedia equipment","search_zh":"多媒体设备 PN-EN 55035:2017-09 | PN-EN 55035:2017-09/A11:2020-09","test_object_zh":"多媒体设备"},{"_id":"6a832b21884ede9a1b2c5480","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Lampy, osprzęt pomocniczy i oprawy oświetleniowe, przewidzianego do zasilania z sieci niskiego napięcia lub z akumulatorów","methodology":"Odporność elektromagnetyczna - bez odporności na pole magnetyczne o częstotliwości sieci energetycznej oraz bez odporności na zapady napięcia, krótkie przerwy i zmiany napięcia, Electromagnetic immunity – without power frequency magnetic field immunity and voltage dips, short interruptions and voltage variations immunity","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność elektromagnetyczna - bez odporności na pole magnetyczne o częstotliwości sieci energetycznej oraz bez odporności na zapady napięcia, krótkie przerwy i zmiany napięcia, Electromagnetic immunity – without power frequency magnetic field immunity and voltage dips, short interruptions and voltage variations immunity","reference":"PN-EN 61547:2009 | PN-EN IEC 61547:2023-10","norm_bases":["PN-EN 61547:2009","PN-EN IEC 61547:2023-10"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Lampy, osprzęt pomocniczy i oprawy oświetleniowe, przewidzianego do zasilania z sieci niskiego napięcia lub z akumulatorów Odporność elektromagnetyczna - bez odporności na pole magnetyczne o częstotliwości sieci energetycznej oraz bez odporności na zapady napięcia, krótkie przerwy i zmiany napięcia, Electromagnetic immunity – without power frequency magnetic field immunity and voltage dips, short interruptions and voltage variations immunity PN-EN 61547:2009 | PN-EN IEC 61547:2023-10 Lampy, osprzet pomocniczy i oprawy oswietleniowe, przewidzianego do zasilania z sieci niskiego napiecia lub z akumulatorow Odpornosc elektromagnetyczna - bez odpornosci na pole magnetyczne o czestotliwosci sieci energetycznej oraz bez odpornosci na zapady napiecia, krotkie przerwy i zmiany napiecia, Electromagnetic immunity – without power frequency magnetic field immunity and voltage dips, short interruptions and voltage variations immunity PN-EN 61547:2009 | PN-EN IEC 61547:2023-10","categories":["other"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Lamps, auxiliary equipment and luminaires intended for supply from low-voltage mains or from batteries PN-EN 61547:2009 | PN-EN IEC 61547:2023-10","test_object_en":"Lamps, auxiliary equipment and luminaires intended for supply from low-voltage mains or from batteries"},{"_id":"6a832b21884ede9a1b2c5481","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Terminale telefonii komórkowej GSM 900, DCS-1800","methodology":"Swoiste tempo pochłaniania energii, SAR","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Swoiste tempo pochłaniania energii, SAR","reference":"PN-EN 50360:2017-11","norm_bases":["PN-EN 50360:2017-11"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Terminale telefonii komórkowej GSM 900, DCS-1800 Swoiste tempo pochłaniania energii, SAR PN-EN 50360:2017-11 Terminale telefonii komorkowej GSM 900, DCS-1800 Swoiste tempo pochlaniania energii, SAR PN-EN 50360:2017-11","categories":["other"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specific absorption rate, SAR","search_en":"Mobile telephony terminals GSM 900, DCS-1800 Specific absorption rate, SAR PN-EN 50360:2017-11","test_object_en":"Mobile telephony terminals GSM 900, DCS-1800"},{"_id":"6a832b21884ede9a1b2c5482","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz","methodology":"Pole magnetyczne nadajnika, Transmitter H-field","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pole magnetyczne nadajnika, Transmitter H-field","reference":"PN-ETSI EN 300 330 V2.1.1:2017-08","norm_bases":["PN-ETSI EN 300 330 V2.1.1:2017-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz Pole magnetyczne nadajnika, Transmitter H-field PN-ETSI EN 300 330 V2.1.1:2017-08 Urzadzenia radiowe bliskiego zasiegu pracujace w zakresie czestotliwosci od 9 kHz do 40 GHz Pole magnetyczne nadajnika, Transmitter H-field PN-ETSI EN 300 330 V2.1.1:2017-08","categories":["other"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Transmitter H-field","search_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz Transmitter H-field PN-ETSI EN 300 330 V2.1.1:2017-08","test_object_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz","search_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备 PN-ETSI EN 300 330 V2.1.1:2017-08","test_object_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备"},{"_id":"6a832b21884ede9a1b2c5483","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz","methodology":"Promieniowane pole elektryczne nadajnika, Transmitter radiated E-field","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Promieniowane pole elektryczne nadajnika, Transmitter radiated E-field","reference":"PN-ETSI EN 300 330 V2.1.1:2017-08","norm_bases":["PN-ETSI EN 300 330 V2.1.1:2017-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz Promieniowane pole elektryczne nadajnika, Transmitter radiated E-field PN-ETSI EN 300 330 V2.1.1:2017-08 Urzadzenia radiowe bliskiego zasiegu pracujace w zakresie czestotliwosci od 9 kHz do 40 GHz Promieniowane pole elektryczne nadajnika, Transmitter radiated E-field PN-ETSI EN 300 330 V2.1.1:2017-08","categories":["other"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz PN-ETSI EN 300 330 V2.1.1:2017-08","test_object_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz","search_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备 PN-ETSI EN 300 330 V2.1.1:2017-08","test_object_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备"},{"_id":"6a832b21884ede9a1b2c5484","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz","methodology":"Zakresy częstotliwości pracy, Operating frequency ranges","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zakresy częstotliwości pracy, Operating frequency ranges","reference":"PN-ETSI EN 300 330 V2.1.1:2017-08","norm_bases":["PN-ETSI EN 300 330 V2.1.1:2017-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz Zakresy częstotliwości pracy, Operating frequency ranges PN-ETSI EN 300 330 V2.1.1:2017-08 Urzadzenia radiowe bliskiego zasiegu pracujace w zakresie czestotliwosci od 9 kHz do 40 GHz Zakresy czestotliwosci pracy, Operating frequency ranges PN-ETSI EN 300 330 V2.1.1:2017-08","categories":["other"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz PN-ETSI EN 300 330 V2.1.1:2017-08","test_object_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz","search_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备 PN-ETSI EN 300 330 V2.1.1:2017-08","test_object_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备"},{"_id":"6a832b21884ede9a1b2c5485","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz","methodology":"Szerokość pasma modulacji, Modulation bandwidth","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Szerokość pasma modulacji, Modulation bandwidth","reference":"PN-ETSI EN 300 330 V2.1.1:2017-08","norm_bases":["PN-ETSI EN 300 330 V2.1.1:2017-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz Szerokość pasma modulacji, Modulation bandwidth PN-ETSI EN 300 330 V2.1.1:2017-08 Urzadzenia radiowe bliskiego zasiegu pracujace w zakresie czestotliwosci od 9 kHz do 40 GHz Szerokosc pasma modulacji, Modulation bandwidth PN-ETSI EN 300 330 V2.1.1:2017-08","categories":["other"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Modulation bandwidth","search_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz Modulation bandwidth PN-ETSI EN 300 330 V2.1.1:2017-08","test_object_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz","search_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备 PN-ETSI EN 300 330 V2.1.1:2017-08","test_object_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备"},{"_id":"6a832b21884ede9a1b2c5486","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz","methodology":"Promieniowane emisje niepożądane nadajnika < 30 MHz, Transmitter radiated spurious domain emission limits < 30 MHz","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Promieniowane emisje niepożądane nadajnika < 30 MHz, Transmitter radiated spurious domain emission limits < 30 MHz","reference":"PN-ETSI EN 300 330 V2.1.1:2017-08","norm_bases":["PN-ETSI EN 300 330 V2.1.1:2017-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz Promieniowane emisje niepożądane nadajnika < 30 MHz, Transmitter radiated spurious domain emission limits < 30 MHz PN-ETSI EN 300 330 V2.1.1:2017-08 Urzadzenia radiowe bliskiego zasiegu pracujace w zakresie czestotliwosci od 9 kHz do 40 GHz Promieniowane emisje niepozadane nadajnika < 30 MHz, Transmitter radiated spurious domain emission limits < 30 MHz PN-ETSI EN 300 330 V2.1.1:2017-08","categories":["environment"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Transmitter radiated spurious domain emission limits < 30 MHz","search_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz Transmitter radiated spurious domain emission limits < 30 MHz PN-ETSI EN 300 330 V2.1.1:2017-08","test_object_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz","search_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备 PN-ETSI EN 300 330 V2.1.1:2017-08","test_object_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备"},{"_id":"6a832b21884ede9a1b2c5487","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz","methodology":"Promieniowane emisje niepożądane nadajnika > 30 MHz, Transmitter radiated spurious domain emission limits > 30 MHz","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Promieniowane emisje niepożądane nadajnika > 30 MHz, Transmitter radiated spurious domain emission limits > 30 MHz","reference":"PN-ETSI EN 300 330 V2.1.1:2017-08","norm_bases":["PN-ETSI EN 300 330 V2.1.1:2017-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz Promieniowane emisje niepożądane nadajnika > 30 MHz, Transmitter radiated spurious domain emission limits > 30 MHz PN-ETSI EN 300 330 V2.1.1:2017-08 Urzadzenia radiowe bliskiego zasiegu pracujace w zakresie czestotliwosci od 9 kHz do 40 GHz Promieniowane emisje niepozadane nadajnika > 30 MHz, Transmitter radiated spurious domain emission limits > 30 MHz PN-ETSI EN 300 330 V2.1.1:2017-08","categories":["environment"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Transmitter radiated spurious domain emission limits > 30 MHz","search_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz Transmitter radiated spurious domain emission limits > 30 MHz PN-ETSI EN 300 330 V2.1.1:2017-08","test_object_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz","search_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备 PN-ETSI EN 300 330 V2.1.1:2017-08","test_object_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备"},{"_id":"6a832b21884ede9a1b2c5488","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz","methodology":"Emisje niepożądane odbiornika, Receiver spurious emissions","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisje niepożądane odbiornika, Receiver spurious emissions","reference":"PN-ETSI EN 300 330 V2.1.1:2017-08","norm_bases":["PN-ETSI EN 300 330 V2.1.1:2017-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz Emisje niepożądane odbiornika, Receiver spurious emissions PN-ETSI EN 300 330 V2.1.1:2017-08 Urzadzenia radiowe bliskiego zasiegu pracujace w zakresie czestotliwosci od 9 kHz do 40 GHz Emisje niepozadane odbiornika, Receiver spurious emissions PN-ETSI EN 300 330 V2.1.1:2017-08","categories":["environment"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Receiver spurious emissions, Receiver spurious emissions","search_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz Receiver spurious emissions, Receiver spurious emissions PN-ETSI EN 300 330 V2.1.1:2017-08","test_object_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz","search_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备 接收机杂散发射 Receiver spurious emissions PN-ETSI EN 300 330 V2.1.1:2017-08","test_object_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备","methodology_zh":"接收机杂散发射 Receiver spurious emissions"},{"_id":"6a832b21884ede9a1b2c5489","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz","methodology":"Odchyłka częstotliwości, Frequency error","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odchyłka częstotliwości, Frequency error","reference":"PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","norm_bases":["PN-ETSI EN 300 220-1 V3.1.1:2017-08","PN-ETSI EN 300 220-2 V3.1.1:2017-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz Odchyłka częstotliwości, Frequency error PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08 Urzadzenia radiowe bliskiego zasiegu pracujace w zakresie czestotliwosci od 9 kHz do 40 GHz Odchylka czestotliwosci, Frequency error PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","categories":["other"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency error","search_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz Frequency error PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz","search_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备 频率误差 / Frequency error PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备","methodology_zh":"频率误差 / Frequency error"},{"_id":"6a832b21884ede9a1b2c548a","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz","methodology":"Równoważna moc promieniowana, Effective radiated power","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważna moc promieniowana, Effective radiated power","reference":"PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","norm_bases":["PN-ETSI EN 300 220-1 V3.1.1:2017-08","PN-ETSI EN 300 220-2 V3.1.1:2017-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz Równoważna moc promieniowana, Effective radiated power PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08 Urzadzenia radiowe bliskiego zasiegu pracujace w zakresie czestotliwosci od 9 kHz do 40 GHz Rownowazna moc promieniowana, Effective radiated power PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","categories":["other"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective radiated power, Effective radiated power","search_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz Effective radiated power, Effective radiated power PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz","search_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备 PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备"},{"_id":"6a832b21884ede9a1b2c548b","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz","methodology":"Moc w kanale sąsiednim, Adjacent channel power","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Moc w kanale sąsiednim, Adjacent channel power","reference":"PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","norm_bases":["PN-ETSI EN 300 220-1 V3.1.1:2017-08","PN-ETSI EN 300 220-2 V3.1.1:2017-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz Moc w kanale sąsiednim, Adjacent channel power PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08 Urzadzenia radiowe bliskiego zasiegu pracujace w zakresie czestotliwosci od 9 kHz do 40 GHz Moc w kanale sasiednim, Adjacent channel power PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","categories":["other"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Adjacent channel power","search_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz Adjacent channel power PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz","search_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备 PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备"},{"_id":"6a832b21884ede9a1b2c548c","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz","methodology":"Szerokość zajmowanego pasma, Occupied bandwidth","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Szerokość zajmowanego pasma, Occupied bandwidth","reference":"PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","norm_bases":["PN-ETSI EN 300 220-1 V3.1.1:2017-08","PN-ETSI EN 300 220-2 V3.1.1:2017-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz Szerokość zajmowanego pasma, Occupied bandwidth PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08 Urzadzenia radiowe bliskiego zasiegu pracujace w zakresie czestotliwosci od 9 kHz do 40 GHz Szerokosc zajmowanego pasma, Occupied bandwidth PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","categories":["other"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Occupied bandwidth, Occupied bandwidth","search_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz Occupied bandwidth, Occupied bandwidth PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz","search_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备 PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备"},{"_id":"6a832b21884ede9a1b2c548d","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz","methodology":"Emisje niepożądane, Unwanted emissions in the spurious domain","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisje niepożądane, Unwanted emissions in the spurious domain","reference":"PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","norm_bases":["PN-ETSI EN 300 220-1 V3.1.1:2017-08","PN-ETSI EN 300 220-2 V3.1.1:2017-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz Emisje niepożądane, Unwanted emissions in the spurious domain PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08 Urzadzenia radiowe bliskiego zasiegu pracujace w zakresie czestotliwosci od 9 kHz do 40 GHz Emisje niepozadane, Unwanted emissions in the spurious domain PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","categories":["environment"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz","search_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备 PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备"},{"_id":"6a832b21884ede9a1b2c548e","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz","methodology":"Emisje pozapasmowe nadajnika, Tx Out of Band emissions","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisje pozapasmowe nadajnika, Tx Out of Band emissions","reference":"PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","norm_bases":["PN-ETSI EN 300 220-1 V3.1.1:2017-08","PN-ETSI EN 300 220-2 V3.1.1:2017-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz Emisje pozapasmowe nadajnika, Tx Out of Band emissions PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08 Urzadzenia radiowe bliskiego zasiegu pracujace w zakresie czestotliwosci od 9 kHz do 40 GHz Emisje pozapasmowe nadajnika, Tx Out of Band emissions PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","categories":["environment"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz","search_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备 PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备"},{"_id":"6a832b21884ede9a1b2c548f","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz","methodology":"Selektywność sąsiedniokanałowa, Adjacent channel selectivity","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Selektywność sąsiedniokanałowa, Adjacent channel selectivity","reference":"PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","norm_bases":["PN-ETSI EN 300 220-1 V3.1.1:2017-08","PN-ETSI EN 300 220-2 V3.1.1:2017-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz Selektywność sąsiedniokanałowa, Adjacent channel selectivity PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08 Urzadzenia radiowe bliskiego zasiegu pracujace w zakresie czestotliwosci od 9 kHz do 40 GHz Selektywnosc sasiedniokanalowa, Adjacent channel selectivity PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","categories":["other"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Adjacent channel selectivity, Adjacent channel selectivity","search_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz Adjacent channel selectivity, Adjacent channel selectivity PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz","search_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备 邻道选择性 Adjacent channel selectivity PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备","methodology_zh":"邻道选择性 Adjacent channel selectivity"},{"_id":"6a832b21884ede9a1b2c5490","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz","methodology":"Blokowanie, Blocking","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Blokowanie, Blocking","reference":"PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","norm_bases":["PN-ETSI EN 300 220-1 V3.1.1:2017-08","PN-ETSI EN 300 220-2 V3.1.1:2017-08"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz Blokowanie, Blocking PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08 Urzadzenia radiowe bliskiego zasiegu pracujace w zakresie czestotliwosci od 9 kHz do 40 GHz Blokowanie, Blocking PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","categories":["other"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Blocking","search_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz Blocking PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz","search_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备 PN-ETSI EN 300 220-1 V3.1.1:2017-08 | PN-ETSI EN 300 220-2 V3.1.1:2017-08","test_object_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备"},{"_id":"6a832b21884ede9a1b2c5491","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz","methodology":"Równoważna moc promieniowana izotropowo e.i.r.p., Equivalent isotropically radiated power (e.i.r.p.)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważna moc promieniowana izotropowo e.i.r.p., Equivalent isotropically radiated power (e.i.r.p.)","reference":"PN-ETSI EN 300 440 V2.1.1:2017-10","norm_bases":["PN-ETSI EN 300 440 V2.1.1:2017-10"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz Równoważna moc promieniowana izotropowo e.i.r.p., Equivalent isotropically radiated power (e.i.r.p.) PN-ETSI EN 300 440 V2.1.1:2017-10 Urzadzenia radiowe bliskiego zasiegu pracujace w zakresie czestotliwosci od 9 kHz do 40 GHz Rownowazna moc promieniowana izotropowo e.i.r.p., Equivalent isotropically radiated power (e.i.r.p.) PN-ETSI EN 300 440 V2.1.1:2017-10","categories":["other"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Equivalent isotropically radiated power (e.i.r.p.)","search_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz Equivalent isotropically radiated power (e.i.r.p.) PN-ETSI EN 300 440 V2.1.1:2017-10","test_object_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz","search_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备 PN-ETSI EN 300 440 V2.1.1:2017-10","test_object_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备"},{"_id":"6a832b21884ede9a1b2c5492","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz","methodology":"Dozwolony zakres częstotliwości pracy, Permitted range of operating frequencies","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Dozwolony zakres częstotliwości pracy, Permitted range of operating frequencies","reference":"PN-ETSI EN 300 440 V2.1.1:2017-10","norm_bases":["PN-ETSI EN 300 440 V2.1.1:2017-10"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz Dozwolony zakres częstotliwości pracy, Permitted range of operating frequencies PN-ETSI EN 300 440 V2.1.1:2017-10 Urzadzenia radiowe bliskiego zasiegu pracujace w zakresie czestotliwosci od 9 kHz do 40 GHz Dozwolony zakres czestotliwosci pracy, Permitted range of operating frequencies PN-ETSI EN 300 440 V2.1.1:2017-10","categories":["other"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz PN-ETSI EN 300 440 V2.1.1:2017-10","test_object_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz","search_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备 PN-ETSI EN 300 440 V2.1.1:2017-10","test_object_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备"},{"_id":"6a832b21884ede9a1b2c5493","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz","methodology":"Emisje niepożądane nadajnika, Unwanted emissions in the spurious domain","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisje niepożądane nadajnika, Unwanted emissions in the spurious domain","reference":"PN-ETSI EN 300 440 V2.1.1:2017-10","norm_bases":["PN-ETSI EN 300 440 V2.1.1:2017-10"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz Emisje niepożądane nadajnika, Unwanted emissions in the spurious domain PN-ETSI EN 300 440 V2.1.1:2017-10 Urzadzenia radiowe bliskiego zasiegu pracujace w zakresie czestotliwosci od 9 kHz do 40 GHz Emisje niepozadane nadajnika, Unwanted emissions in the spurious domain PN-ETSI EN 300 440 V2.1.1:2017-10","categories":["environment"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz PN-ETSI EN 300 440 V2.1.1:2017-10","test_object_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz","search_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备 PN-ETSI EN 300 440 V2.1.1:2017-10","test_object_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备"},{"_id":"6a832b21884ede9a1b2c5494","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz","methodology":"Selektywność sąsiedniokanałowa, Adjacent channel selectivity","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Selektywność sąsiedniokanałowa, Adjacent channel selectivity","reference":"PN-ETSI EN 300 440 V2.1.1:2017-10","norm_bases":["PN-ETSI EN 300 440 V2.1.1:2017-10"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz Selektywność sąsiedniokanałowa, Adjacent channel selectivity PN-ETSI EN 300 440 V2.1.1:2017-10 Urzadzenia radiowe bliskiego zasiegu pracujace w zakresie czestotliwosci od 9 kHz do 40 GHz Selektywnosc sasiedniokanalowa, Adjacent channel selectivity PN-ETSI EN 300 440 V2.1.1:2017-10","categories":["other"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Adjacent channel selectivity, Adjacent channel selectivity","search_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz Adjacent channel selectivity, Adjacent channel selectivity PN-ETSI EN 300 440 V2.1.1:2017-10","test_object_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz","search_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备 邻道选择性 Adjacent channel selectivity PN-ETSI EN 300 440 V2.1.1:2017-10","test_object_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备","methodology_zh":"邻道选择性 Adjacent channel selectivity"},{"_id":"6a832b21884ede9a1b2c5495","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz","methodology":"Blokowanie lub zmniejszenie czułości, Blocking or desensitization","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Blokowanie lub zmniejszenie czułości, Blocking or desensitization","reference":"PN-ETSI EN 300 440 V2.1.1:2017-10","norm_bases":["PN-ETSI EN 300 440 V2.1.1:2017-10"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz Blokowanie lub zmniejszenie czułości, Blocking or desensitization PN-ETSI EN 300 440 V2.1.1:2017-10 Urzadzenia radiowe bliskiego zasiegu pracujace w zakresie czestotliwosci od 9 kHz do 40 GHz Blokowanie lub zmniejszenie czulosci, Blocking or desensitization PN-ETSI EN 300 440 V2.1.1:2017-10","categories":["other"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Blocking or desensitization","search_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz Blocking or desensitization PN-ETSI EN 300 440 V2.1.1:2017-10","test_object_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz","search_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备 PN-ETSI EN 300 440 V2.1.1:2017-10","test_object_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备"},{"_id":"6a832b21884ede9a1b2c5496","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz","methodology":"Emisje niepożądane odbiornika, Spurious radiations","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisje niepożądane odbiornika, Spurious radiations","reference":"PN-ETSI EN 300 440 V2.1.1:2017-10","norm_bases":["PN-ETSI EN 300 440 V2.1.1:2017-10"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia radiowe bliskiego zasięgu pracujące w zakresie częstotliwości od 9 kHz do 40 GHz Emisje niepożądane odbiornika, Spurious radiations PN-ETSI EN 300 440 V2.1.1:2017-10 Urzadzenia radiowe bliskiego zasiegu pracujace w zakresie czestotliwosci od 9 kHz do 40 GHz Emisje niepozadane odbiornika, Spurious radiations PN-ETSI EN 300 440 V2.1.1:2017-10","categories":["other"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Receiver spurious emissions, Spurious radiations","search_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz Receiver spurious emissions, Spurious radiations PN-ETSI EN 300 440 V2.1.1:2017-10","test_object_en":"Short range radio equipment operating in the frequency range from 9 kHz to 40 GHz","search_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备 PN-ETSI EN 300 440 V2.1.1:2017-10","test_object_zh":"工作频率 9 kHz 至 40 GHz 的短距离无线电设备"},{"_id":"6a832b21884ede9a1b2c5497","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 2,4 GHz ISM","methodology":"Moc wyjściowa RF, RF output power","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Moc wyjściowa RF, RF output power","reference":"PN-ETSI EN 300 328 V2.1.1:2017-05","norm_bases":["PN-ETSI EN 300 328 V2.1.1:2017-05"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 2,4 GHz ISM Moc wyjściowa RF, RF output power PN-ETSI EN 300 328 V2.1.1:2017-05 Urzadzenia bezprzewodowej transmisji cyfrowej pracujace w pasmie czestotliwosci 2,4 GHz ISM Moc wyjsciowa RF, RF output power PN-ETSI EN 300 328 V2.1.1:2017-05","categories":["other"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"RF output power","search_en":"Wireless digital transmission equipment operating in the 2,4 GHz ISM frequency band RF output power PN-ETSI EN 300 328 V2.1.1:2017-05","test_object_en":"Wireless digital transmission equipment operating in the 2,4 GHz ISM frequency band","search_zh":"工作于 2,4 GHz ISM 频段的无线数字传输设备 PN-ETSI EN 300 328 V2.1.1:2017-05","test_object_zh":"工作于 2,4 GHz ISM 频段的无线数字传输设备"},{"_id":"6a832b21884ede9a1b2c5498","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 2,4 GHz ISM","methodology":"Widmowa gęstość mocy, Power spectral density","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Widmowa gęstość mocy, Power spectral density","reference":"PN-ETSI EN 300 328 V2.1.1:2017-05","norm_bases":["PN-ETSI EN 300 328 V2.1.1:2017-05"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 2,4 GHz ISM Widmowa gęstość mocy, Power spectral density PN-ETSI EN 300 328 V2.1.1:2017-05 Urzadzenia bezprzewodowej transmisji cyfrowej pracujace w pasmie czestotliwosci 2,4 GHz ISM Widmowa gestosc mocy, Power spectral density PN-ETSI EN 300 328 V2.1.1:2017-05","categories":["other"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Power spectral density","search_en":"Wireless digital transmission equipment operating in the 2,4 GHz ISM frequency band Power spectral density PN-ETSI EN 300 328 V2.1.1:2017-05","test_object_en":"Wireless digital transmission equipment operating in the 2,4 GHz ISM frequency band","search_zh":"工作于 2,4 GHz ISM 频段的无线数字传输设备 PN-ETSI EN 300 328 V2.1.1:2017-05","test_object_zh":"工作于 2,4 GHz ISM 频段的无线数字传输设备"},{"_id":"6a832b21884ede9a1b2c5499","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 2,4 GHz ISM","methodology":"Szerokość pasma zajmowanego kanału, Occupied channel bandwidth","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Szerokość pasma zajmowanego kanału, Occupied channel bandwidth","reference":"PN-ETSI EN 300 328 V2.1.1:2017-05","norm_bases":["PN-ETSI EN 300 328 V2.1.1:2017-05"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 2,4 GHz ISM Szerokość pasma zajmowanego kanału, Occupied channel bandwidth PN-ETSI EN 300 328 V2.1.1:2017-05 Urzadzenia bezprzewodowej transmisji cyfrowej pracujace w pasmie czestotliwosci 2,4 GHz ISM Szerokosc pasma zajmowanego kanalu, Occupied channel bandwidth PN-ETSI EN 300 328 V2.1.1:2017-05","categories":["other"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Occupied channel bandwidth, Occupied channel bandwidth","search_en":"Wireless digital transmission equipment operating in the 2,4 GHz ISM frequency band Occupied channel bandwidth, Occupied channel bandwidth PN-ETSI EN 300 328 V2.1.1:2017-05","test_object_en":"Wireless digital transmission equipment operating in the 2,4 GHz ISM frequency band","search_zh":"工作于 2,4 GHz ISM 频段的无线数字传输设备 PN-ETSI EN 300 328 V2.1.1:2017-05","test_object_zh":"工作于 2,4 GHz ISM 频段的无线数字传输设备"},{"_id":"6a832b21884ede9a1b2c549a","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 2,4 GHz ISM","methodology":"Emisje pozapasmowe nadajnika, Transmitter unwanted emissions in the OOB domain","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisje pozapasmowe nadajnika, Transmitter unwanted emissions in the OOB domain","reference":"PN-ETSI EN 300 328 V2.1.1:2017-05","norm_bases":["PN-ETSI EN 300 328 V2.1.1:2017-05"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 2,4 GHz ISM Emisje pozapasmowe nadajnika, Transmitter unwanted emissions in the OOB domain PN-ETSI EN 300 328 V2.1.1:2017-05 Urzadzenia bezprzewodowej transmisji cyfrowej pracujace w pasmie czestotliwosci 2,4 GHz ISM Emisje pozapasmowe nadajnika, Transmitter unwanted emissions in the OOB domain PN-ETSI EN 300 328 V2.1.1:2017-05","categories":["environment"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Wireless digital transmission equipment operating in the 2,4 GHz ISM frequency band PN-ETSI EN 300 328 V2.1.1:2017-05","test_object_en":"Wireless digital transmission equipment operating in the 2,4 GHz ISM frequency band","search_zh":"工作于 2,4 GHz ISM 频段的无线数字传输设备 PN-ETSI EN 300 328 V2.1.1:2017-05","test_object_zh":"工作于 2,4 GHz ISM 频段的无线数字传输设备"},{"_id":"6a832b21884ede9a1b2c549b","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 2,4 GHz ISM","methodology":"Emisje niepożądane nadajnika, Transmitter unwanted emissions in the spurious domain","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisje niepożądane nadajnika, Transmitter unwanted emissions in the spurious domain","reference":"PN-ETSI EN 300 328 V2.1.1:2017-05","norm_bases":["PN-ETSI EN 300 328 V2.1.1:2017-05"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 2,4 GHz ISM Emisje niepożądane nadajnika, Transmitter unwanted emissions in the spurious domain PN-ETSI EN 300 328 V2.1.1:2017-05 Urzadzenia bezprzewodowej transmisji cyfrowej pracujace w pasmie czestotliwosci 2,4 GHz ISM Emisje niepozadane nadajnika, Transmitter unwanted emissions in the spurious domain PN-ETSI EN 300 328 V2.1.1:2017-05","categories":["environment"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Wireless digital transmission equipment operating in the 2,4 GHz ISM frequency band PN-ETSI EN 300 328 V2.1.1:2017-05","test_object_en":"Wireless digital transmission equipment operating in the 2,4 GHz ISM frequency band","search_zh":"工作于 2,4 GHz ISM 频段的无线数字传输设备 PN-ETSI EN 300 328 V2.1.1:2017-05","test_object_zh":"工作于 2,4 GHz ISM 频段的无线数字传输设备"},{"_id":"6a832b21884ede9a1b2c549c","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 2,4 GHz ISM","methodology":"Emisje niepożądane odbiornika, Receiver spurious emissions","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisje niepożądane odbiornika, Receiver spurious emissions","reference":"PN-ETSI EN 300 328 V2.1.1:2017-05","norm_bases":["PN-ETSI EN 300 328 V2.1.1:2017-05"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 2,4 GHz ISM Emisje niepożądane odbiornika, Receiver spurious emissions PN-ETSI EN 300 328 V2.1.1:2017-05 Urzadzenia bezprzewodowej transmisji cyfrowej pracujace w pasmie czestotliwosci 2,4 GHz ISM Emisje niepozadane odbiornika, Receiver spurious emissions PN-ETSI EN 300 328 V2.1.1:2017-05","categories":["environment"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Receiver spurious emissions, Receiver spurious emissions","search_en":"Wireless digital transmission equipment operating in the 2,4 GHz ISM frequency band Receiver spurious emissions, Receiver spurious emissions PN-ETSI EN 300 328 V2.1.1:2017-05","test_object_en":"Wireless digital transmission equipment operating in the 2,4 GHz ISM frequency band","search_zh":"工作于 2,4 GHz ISM 频段的无线数字传输设备 接收机杂散发射 Receiver spurious emissions PN-ETSI EN 300 328 V2.1.1:2017-05","test_object_zh":"工作于 2,4 GHz ISM 频段的无线数字传输设备","methodology_zh":"接收机杂散发射 Receiver spurious emissions"},{"_id":"6a832b21884ede9a1b2c549d","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 5 GHz ISM","methodology":"Nominalne częstotliwości kanałów, Nominal carrier frequencies","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nominalne częstotliwości kanałów, Nominal carrier frequencies","reference":"PN-ETSI EN 301 893 V2.1.1:2017-11","norm_bases":["PN-ETSI EN 301 893 V2.1.1:2017-11"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 5 GHz ISM Nominalne częstotliwości kanałów, Nominal carrier frequencies PN-ETSI EN 301 893 V2.1.1:2017-11 Urzadzenia bezprzewodowej transmisji cyfrowej pracujace w pasmie czestotliwosci 5 GHz ISM Nominalne czestotliwosci kanalow, Nominal carrier frequencies PN-ETSI EN 301 893 V2.1.1:2017-11","categories":["other"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nominal channel frequencies, Nominal carrier frequencies","search_en":"Wireless digital transmission equipment operating in the 5 GHz ISM frequency band Nominal channel frequencies, Nominal carrier frequencies PN-ETSI EN 301 893 V2.1.1:2017-11","test_object_en":"Wireless digital transmission equipment operating in the 5 GHz ISM frequency band","search_zh":"工作于 5 GHz ISM 频段的无线数字传输设备 PN-ETSI EN 301 893 V2.1.1:2017-11","test_object_zh":"工作于 5 GHz ISM 频段的无线数字传输设备"},{"_id":"6a832b21884ede9a1b2c549e","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 5 GHz ISM","methodology":"Szerokość pasma zajmowanego kanału, Occupied channel bandwidth","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Szerokość pasma zajmowanego kanału, Occupied channel bandwidth","reference":"PN-ETSI EN 301 893 V2.1.1:2017-11","norm_bases":["PN-ETSI EN 301 893 V2.1.1:2017-11"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 5 GHz ISM Szerokość pasma zajmowanego kanału, Occupied channel bandwidth PN-ETSI EN 301 893 V2.1.1:2017-11 Urzadzenia bezprzewodowej transmisji cyfrowej pracujace w pasmie czestotliwosci 5 GHz ISM Szerokosc pasma zajmowanego kanalu, Occupied channel bandwidth PN-ETSI EN 301 893 V2.1.1:2017-11","categories":["other"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Occupied channel bandwidth, Occupied channel bandwidth","search_en":"Wireless digital transmission equipment operating in the 5 GHz ISM frequency band Occupied channel bandwidth, Occupied channel bandwidth PN-ETSI EN 301 893 V2.1.1:2017-11","test_object_en":"Wireless digital transmission equipment operating in the 5 GHz ISM frequency band","search_zh":"工作于 5 GHz ISM 频段的无线数字传输设备 PN-ETSI EN 301 893 V2.1.1:2017-11","test_object_zh":"工作于 5 GHz ISM 频段的无线数字传输设备"},{"_id":"6a832b21884ede9a1b2c549f","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 5 GHz ISM","methodology":"Moc wyjściowa RF, sterowanie mocą (TPC) oraz gęstość mocy, RF output Power, Transmit Power Control (TPC) and Power Density","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Moc wyjściowa RF, sterowanie mocą (TPC) oraz gęstość mocy, RF output Power, Transmit Power Control (TPC) and Power Density","reference":"PN-ETSI EN 301 893 V2.1.1:2017-11","norm_bases":["PN-ETSI EN 301 893 V2.1.1:2017-11"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 5 GHz ISM Moc wyjściowa RF, sterowanie mocą (TPC) oraz gęstość mocy, RF output Power, Transmit Power Control (TPC) and Power Density PN-ETSI EN 301 893 V2.1.1:2017-11 Urzadzenia bezprzewodowej transmisji cyfrowej pracujace w pasmie czestotliwosci 5 GHz ISM Moc wyjsciowa RF, sterowanie moca (TPC) oraz gestosc mocy, RF output Power, Transmit Power Control (TPC) and Power Density PN-ETSI EN 301 893 V2.1.1:2017-11","categories":["other"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Wireless digital transmission equipment operating in the 5 GHz ISM frequency band PN-ETSI EN 301 893 V2.1.1:2017-11","test_object_en":"Wireless digital transmission equipment operating in the 5 GHz ISM frequency band","search_zh":"工作于 5 GHz ISM 频段的无线数字传输设备 PN-ETSI EN 301 893 V2.1.1:2017-11","test_object_zh":"工作于 5 GHz ISM 频段的无线数字传输设备"},{"_id":"6a832b21884ede9a1b2c54a0","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 5 GHz ISM","methodology":"Emisje niepożądane w granicach pasm RLAN 5 GHz, Transmitter unwanted emissions within the 5 GHz RLAN bands","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisje niepożądane w granicach pasm RLAN 5 GHz, Transmitter unwanted emissions within the 5 GHz RLAN bands","reference":"PN-ETSI EN 301 893 V2.1.1:2017-11","norm_bases":["PN-ETSI EN 301 893 V2.1.1:2017-11"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 5 GHz ISM Emisje niepożądane w granicach pasm RLAN 5 GHz, Transmitter unwanted emissions within the 5 GHz RLAN bands PN-ETSI EN 301 893 V2.1.1:2017-11 Urzadzenia bezprzewodowej transmisji cyfrowej pracujace w pasmie czestotliwosci 5 GHz ISM Emisje niepozadane w granicach pasm RLAN 5 GHz, Transmitter unwanted emissions within the 5 GHz RLAN bands PN-ETSI EN 301 893 V2.1.1:2017-11","categories":["environment"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Wireless digital transmission equipment operating in the 5 GHz ISM frequency band PN-ETSI EN 301 893 V2.1.1:2017-11","test_object_en":"Wireless digital transmission equipment operating in the 5 GHz ISM frequency band","search_zh":"工作于 5 GHz ISM 频段的无线数字传输设备 PN-ETSI EN 301 893 V2.1.1:2017-11","test_object_zh":"工作于 5 GHz ISM 频段的无线数字传输设备"},{"_id":"6a832b21884ede9a1b2c54a1","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 5 GHz ISM","methodology":"Emisje niepożądane poza pasmami RLAN 5 GHz, Transmitter unwanted emissions outside the 5 GHz RLAN bands","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisje niepożądane poza pasmami RLAN 5 GHz, Transmitter unwanted emissions outside the 5 GHz RLAN bands","reference":"PN-ETSI EN 301 893 V2.1.1:2017-11","norm_bases":["PN-ETSI EN 301 893 V2.1.1:2017-11"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 5 GHz ISM Emisje niepożądane poza pasmami RLAN 5 GHz, Transmitter unwanted emissions outside the 5 GHz RLAN bands PN-ETSI EN 301 893 V2.1.1:2017-11 Urzadzenia bezprzewodowej transmisji cyfrowej pracujace w pasmie czestotliwosci 5 GHz ISM Emisje niepozadane poza pasmami RLAN 5 GHz, Transmitter unwanted emissions outside the 5 GHz RLAN bands PN-ETSI EN 301 893 V2.1.1:2017-11","categories":["environment"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Wireless digital transmission equipment operating in the 5 GHz ISM frequency band PN-ETSI EN 301 893 V2.1.1:2017-11","test_object_en":"Wireless digital transmission equipment operating in the 5 GHz ISM frequency band","search_zh":"工作于 5 GHz ISM 频段的无线数字传输设备 PN-ETSI EN 301 893 V2.1.1:2017-11","test_object_zh":"工作于 5 GHz ISM 频段的无线数字传输设备"},{"_id":"6a832b21884ede9a1b2c54a2","lab_id":"69ad52a3de79e566650fb181","country":"PL","accr_number":"AB 245","accr_body":"PCA","test_object":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 5 GHz ISM","methodology":"Emisje niepożądane odbiornika, Receiver spurious emissions","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisje niepożądane odbiornika, Receiver spurious emissions","reference":"PN-ETSI EN 301 893 V2.1.1:2017-11","norm_bases":["PN-ETSI EN 301 893 V2.1.1:2017-11"],"lab_section":"Wydział Centralne Laboratorium Badań Technicznych; Borucza (Gm. Strachówka) 05-304 Stanisławów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia bezprzewodowej transmisji cyfrowej pracujące w paśmie częstotliwości 5 GHz ISM Emisje niepożądane odbiornika, Receiver spurious emissions PN-ETSI EN 301 893 V2.1.1:2017-11 Urzadzenia bezprzewodowej transmisji cyfrowej pracujace w pasmie czestotliwosci 5 GHz ISM Emisje niepozadane odbiornika, Receiver spurious emissions PN-ETSI EN 301 893 V2.1.1:2017-11","categories":["environment"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Receiver spurious emissions, Receiver spurious emissions","search_en":"Wireless digital transmission equipment operating in the 5 GHz ISM frequency band Receiver spurious emissions, Receiver spurious emissions PN-ETSI EN 301 893 V2.1.1:2017-11","test_object_en":"Wireless digital transmission equipment operating in the 5 GHz ISM frequency band","search_zh":"工作于 5 GHz ISM 频段的无线数字传输设备 接收机杂散发射 Receiver spurious emissions PN-ETSI EN 301 893 V2.1.1:2017-11","test_object_zh":"工作于 5 GHz ISM 频段的无线数字传输设备","methodology_zh":"接收机杂散发射 Receiver spurious emissions"}],"has_pdf":true}