{"lab":{"_id":"69ad52a3de79e566650fb171","accr_number":"AB 213","country":"PL","accr_body":"PCA","address":"ul. Owocowa 8, 40-158 Katowice","categories":["water","environment","materials","construction","food","petro","microbiology"],"city":"Katowice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":561,"name":"Eurofins OBIKŚ Polska Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_213.pdf"],"scope_summary":"","search_text":"eurofins obikś polska sp. z o.o. ul. owocowa 8, 40-158 katowice water other environment food pharma electronics petro materials construction metrology automotive microbiology","status":"active","updated_at":"2026-03-08T14:51:05.965Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T15:40:46.930Z","location":{"type":"Point","coordinates":[19.0238,50.2649]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20213,podmiot.html","fields_of_testing":[{"codes":"B/28/P; B/30/P; B/32/P; B/44/P","pl":"Badania biologiczne i biochemiczne i pobieranie próbek wody, ścieków, osadów, środków poprawiających uprawę roślin","en":"Biological and biochemical tests and sampling of water, sewage, sediments, plant growth substances"},{"codes":"B/31; B/32","pl":"Badania biologiczne i biochemiczne gleby, odpadów,","en":"Biological and biochemical tests of soil, waste,"},{"codes":"C/10/P; C/28/P; C/29/P; C/30/P; C/31/P; C/32/P; C/36/P, C/44/P","pl":"Badania chemiczne i pobieranie próbek paliw stałych, wody, wody do spożycia, ścieków, gleby, odpadów, osadów, gazów składowiskowych, biogazu, środków poprawiających uprawę roślin","en":"Chemical tests and sampling of solid fuels, water, drinking water, sewage, soil, waste, sediments, landfill gases, biogas, plant growth substances"},{"codes":"C/3; C/5; C/9;C/22; C/43","pl":"Badania chemiczne obiektów i materiałów biologicznych przeznaczonych do badań, materiałów budowlanych, powietrza, żywności, nawozów,","en":"Chemical tests of biological items and materials for testing, fertilizers, air, food, building materials"},{"codes":"K/9/P; K/28/P; K/29/P; K/30/P; K/32/P","pl":"Badania mikrobiologiczne i pobieranie powietrza, wody, wody do spożycia, ścieków, osadów","en":"Microbiological tests and sampling of air, water, drinking water, sewage, sediments"},{"codes":"K/32","pl":"Badania mikrobiologiczne odpadów","en":"Microbiological tests of waste"}],"issue":{"no":"28","date":"17.04.2026"},"parse_date":"2026-08-17T15:40:46.930Z","parse_source":"agent-claude-code","map_coord":[50.277792,19.024433],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium Siedziba Główna","address":"ul. Owocowa 8/8A; 40-158 Katowice","city":"Katowice","postal":"40-158"},{"name":"Pracownia Badań Terenowych","address":"ul. Owocowa 8/8A; 40-158 Katowice","city":"Katowice","postal":"40-158"},{"name":"Sekcja Badań Biologicznych","address":"ul. Owocowa 8/8A; 40-158 Katowice","city":"Katowice","postal":"40-158"},{"name":"Oddział Katowice","address":"ul. Karoliny 4, 40-186 Katowice","city":"Katowice","postal":"40-186"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/8de205c8104160fc81212eb4759e98da/AB%20213.pdf","has_en":true,"category_counts":{"water":280,"environment":237,"materials":117,"construction":102,"food":54,"petro":42,"other":23,"microbiology":17,"metrology":2},"category_scores":{"water":89.7,"environment":64.27,"materials":15.66,"construction":11.9,"food":3.34,"petro":2.02,"other":0.61,"microbiology":0.33,"metrology":0},"has_zh":true},"methods":[{"_id":"6a832b7f884ede9a1b2c54c8","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda","methodology":"Potencjał utleniająco-redukujący (potencjał redoks)","parameters":[{"name":"Zakres","range":"(-150 – 1000) mV"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Potencjał utleniająco-redukujący (potencjał redoks)\nZakres (-150 – 1000) mV\nMetoda potencjometryczna","reference":"PB/FCH/38/D:03.06.2016","norm_bases":["PB/FCH/38/D:03.06.2016"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Potencjał utleniająco-redukujący (potencjał redoks)\nZakres (-150 – 1000) mV\nMetoda potencjometryczna PB/FCH/38/D:03.06.2016 Woda Potencjal utleniajaco-redukujacy (potencjal redoks)\nZakres (-150 – 1000) mV\nMetoda potencjometryczna PB/FCH/38/D:03.06.2016","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation-reduction potential (redox potential)","parameters_en":[{"name":"Range","range":"(-150 – 1000) mV"}],"search_en":"Water Oxidation-reduction potential (redox potential) Potentiometric method Range PB/FCH/38/D:03.06.2016","technique_en":"Potentiometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(-150 – 1000) mV"}],"search_zh":"水 电位法 范围 PB/FCH/38/D:03.06.2016","technique_zh":"电位法","test_object_zh":"水"},{"_id":"6a832b7f884ede9a1b2c54c9","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie agresywnego ditlenku węgla","parameters":[{"name":"Zakres","range":"(2,2 – 440) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie agresywnego ditlenku węgla\nZakres (2,2 – 440) mg/l\nMetoda miareczkowa","reference":"PN-EN 13577:2008","norm_bases":["PN-EN 13577:2008"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie agresywnego ditlenku węgla\nZakres (2,2 – 440) mg/l\nMetoda miareczkowa PN-EN 13577:2008 Woda Stezenie agresywnego ditlenku wegla\nZakres (2,2 – 440) mg/l\nMetoda miareczkowa PN-EN 13577:2008","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aggressive carbon dioxide concentration","parameters_en":[{"name":"Range","range":"(2,2 – 440) mg/l"}],"search_en":"Water Aggressive carbon dioxide concentration Titrimetric method Range PN-EN 13577:2008","technique_en":"Titrimetric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(2,2 – 440) mg/l"}],"search_zh":"水 滴定法 范围 PN-EN 13577:2008","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a832b7f884ede9a1b2c54ca","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie formaldehydu","parameters":[{"name":"Zakres","range":"(0,02 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie formaldehydu\nZakres (0,02 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"EFO/PB/46/A:05.05.2025","norm_bases":["EFO/PB/46/A:05.05.2025"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie formaldehydu\nZakres (0,02 – 10,0) mg/l\nMetoda spektrofotometryczna EFO/PB/46/A:05.05.2025 Woda Stezenie formaldehydu\nZakres (0,02 – 10,0) mg/l\nMetoda spektrofotometryczna EFO/PB/46/A:05.05.2025","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde concentration","parameters_en":[{"name":"Range","range":"(0,02 – 10,0) mg/l"}],"search_en":"Water Formaldehyde concentration Spectrophotometric method Range EFO/PB/46/A:05.05.2025","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,02 – 10,0) mg/l"}],"search_zh":"水 甲醛浓度 分光光度法 范围 EFO/PB/46/A:05.05.2025","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"甲醛浓度"},{"_id":"6a832b7f884ede9a1b2c54cb","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie kwasu izocyjanurowego","parameters":[{"name":"Zakres","range":"(10 – 160) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie kwasu izocyjanurowego\nZakres (10 – 160) mg/l\nMetoda spektrofotometryczna","reference":"PB/FCH/95/A:05.04.2016 Hanna Instruments Nr cat: HI 93722-01","norm_bases":["PB/FCH/95/A:05.04.2016 Hanna Instruments Nr cat: HI 93722-01"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie kwasu izocyjanurowego\nZakres (10 – 160) mg/l\nMetoda spektrofotometryczna PB/FCH/95/A:05.04.2016 Hanna Instruments Nr cat: HI 93722-01 Woda Stezenie kwasu izocyjanurowego\nZakres (10 – 160) mg/l\nMetoda spektrofotometryczna PB/FCH/95/A:05.04.2016 Hanna Instruments Nr cat: HI 93722-01","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Isocyanuric acid concentration","parameters_en":[{"name":"Range","range":"(10 – 160) mg/l"}],"search_en":"Water Isocyanuric acid concentration Spectrophotometric method Range PB/FCH/95/A:05.04.2016 Hanna Instruments Nr cat: HI 93722-01","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(10 – 160) mg/l"}],"search_zh":"水 异氰尿酸浓度 分光光度法 范围 PB/FCH/95/A:05.04.2016 Hanna Instruments Nr cat: HI 93722-01","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"异氰尿酸浓度"},{"_id":"6a832b7f884ede9a1b2c54cc","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie wolnego ditlenku węgla","parameters":[{"name":"Zakres","range":"(4,4 – 2200) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wolnego ditlenku węgla\nZakres (4,4 – 2200) mg/l\nMetoda miareczkowa","reference":"PN-74/C-04547/01","norm_bases":["PN-74/C-04547/01"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie wolnego ditlenku węgla\nZakres (4,4 – 2200) mg/l\nMetoda miareczkowa PN-74/C-04547/01 Woda Stezenie wolnego ditlenku wegla\nZakres (4,4 – 2200) mg/l\nMetoda miareczkowa PN-74/C-04547/01","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free carbon dioxide concentration","parameters_en":[{"name":"Range","range":"(4,4 – 2200) mg/l"}],"search_en":"Water Free carbon dioxide concentration Titrimetric method Range PN-74/C-04547/01","technique_en":"Titrimetric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(4,4 – 2200) mg/l"}],"search_zh":"水 滴定法 范围 PN-74/C-04547/01","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a832b7f884ede9a1b2c54cd","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie ozonu","parameters":[{"name":"Zakres","range":"(0,04 – 0,50) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie ozonu\nZakres (0,04 – 0,50) mg/l\nMetoda kolorymetryczna","reference":"E F O /PB/22/A:23.06.2023","norm_bases":["E F O /PB/22/A:23.06.2023"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie ozonu\nZakres (0,04 – 0,50) mg/l\nMetoda kolorymetryczna E F O /PB/22/A:23.06.2023 Woda, Woda do spozycia przez ludzi Stezenie ozonu\nZakres (0,04 – 0,50) mg/l\nMetoda kolorymetryczna E F O /PB/22/A:23.06.2023","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ozone concentration","parameters_en":[{"name":"Range","range":"(0,04 – 0,50) mg/l"}],"search_en":"Water, Water intended for human consumption Ozone concentration Colorimetric method Range E F O /PB/22/A:23.06.2023","technique_en":"Colorimetric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,04 – 0,50) mg/l"}],"search_zh":"水、生活饮用水 臭氧浓度 比色法 范围 E F O /PB/22/A:23.06.2023","technique_zh":"比色法","test_object_zh":"水、生活饮用水","methodology_zh":"臭氧浓度"},{"_id":"6a832b7f884ede9a1b2c54ce","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie formaldehydu","parameters":[{"name":"Zakres","range":"(0,01 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie formaldehydu\nZakres (0,01 – 100) mg/l\nMetoda spektrofotometryczna","reference":"EFO/PB/47/A:05.05.2025 na podstawie testu kuwetowego HACH Lange nr LCK 325","norm_bases":["EFO/PB/47/A:05.05.2025 na podstawie testu kuwetowego HACH Lange nr LCK 325"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie formaldehydu\nZakres (0,01 – 100) mg/l\nMetoda spektrofotometryczna EFO/PB/47/A:05.05.2025 na podstawie testu kuwetowego HACH Lange nr LCK 325 Woda, Woda do spozycia przez ludzi Stezenie formaldehydu\nZakres (0,01 – 100) mg/l\nMetoda spektrofotometryczna EFO/PB/47/A:05.05.2025 na podstawie testu kuwetowego HACH Lange nr LCK 325","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde concentration","parameters_en":[{"name":"Range","range":"(0,01 – 100) mg/l"}],"search_en":"Water, Water intended for human consumption Formaldehyde concentration Spectrophotometric method Range EFO/PB/47/A:05.05.2025 na podstawie testu kuwetowego HACH Lange nr LCK 325","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,01 – 100) mg/l"}],"search_zh":"水、生活饮用水 甲醛浓度 分光光度法 范围 EFO/PB/47/A:05.05.2025 na podstawie testu kuwetowego HACH Lange nr LCK 325","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"甲醛浓度"},{"_id":"6a832b7f884ede9a1b2c54cf","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Wody solankowe (solanki)","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(10000 – 150000) mg/l"},{"name":"Zakres","range":"(1,0 – 15,0) %"},{"name":"Stężenie chlorku sodu (z obliczeń)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres:\nZakres (10000 – 150000) mg/l\nZakres (1,0 – 15,0) %\nStężenie chlorku sodu (z obliczeń)\nMetoda miareczkowa","reference":"PN-ISO 9297:1994 PB/FCH/10/E:10.04.2017","norm_bases":["PN-ISO 9297:1994 PB/FCH/10/E:10.04.2017"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody solankowe (solanki) Stężenie chlorków\nZakres:\nZakres (10000 – 150000) mg/l\nZakres (1,0 – 15,0) %\nStężenie chlorku sodu (z obliczeń)\nMetoda miareczkowa PN-ISO 9297:1994 PB/FCH/10/E:10.04.2017 Wody solankowe (solanki) Stezenie chlorkow\nZakres:\nZakres (10000 – 150000) mg/l\nZakres (1,0 – 15,0) %\nStezenie chlorku sodu (z obliczen)\nMetoda miareczkowa PN-ISO 9297:1994 PB/FCH/10/E:10.04.2017","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(10000 – 150000) mg/l"},{"name":"Range","range":"(1,0 – 15,0) %"},{"name":"Sodium chloride concentration (calculated)"}],"search_en":"Brine waters (brines) Chloride concentration Titrimetric method Range Range Sodium chloride concentration (calculated) PN-ISO 9297:1994 PB/FCH/10/E:10.04.2017","technique_en":"Titrimetric method","test_object_en":"Brine waters (brines)","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(10000 – 150000) mg/l"},{"name":"范围","range":"(1,0 – 15,0) %"},{"name":"Stężenie chlorku sodu (z obliczeń)"}],"search_zh":"氯化物浓度 滴定法 范围 范围 PN-ISO 9297:1994 PB/FCH/10/E:10.04.2017","technique_zh":"滴定法"},{"_id":"6a832b7f884ede9a1b2c54d0","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Wody solankowe (solanki)","methodology":"Substancje rozpuszczone ogólne, mineralne","parameters":[{"name":"Zakres","range":"(20000 – 200000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone ogólne, mineralne\nZakres (20000 – 200000) mg/l\nMetoda wagowa","reference":"PN-78/C-04541 PB/FCH/7/C:29.02.2016","norm_bases":["PN-78/C-04541 PB/FCH/7/C:29.02.2016"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody solankowe (solanki) Substancje rozpuszczone ogólne, mineralne\nZakres (20000 – 200000) mg/l\nMetoda wagowa PN-78/C-04541 PB/FCH/7/C:29.02.2016 Wody solankowe (solanki) Substancje rozpuszczone ogolne, mineralne\nZakres (20000 – 200000) mg/l\nMetoda wagowa PN-78/C-04541 PB/FCH/7/C:29.02.2016","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total and mineral dissolved solids","parameters_en":[{"name":"Range","range":"(20000 – 200000) mg/l"}],"search_en":"Brine waters (brines) Total and mineral dissolved solids Gravimetric method Range PN-78/C-04541 PB/FCH/7/C:29.02.2016","technique_en":"Gravimetric method","test_object_en":"Brine waters (brines)","parameters_zh":[{"name":"范围","range":"(20000 – 200000) mg/l"}],"search_zh":"重量法 范围 PN-78/C-04541 PB/FCH/7/C:29.02.2016","technique_zh":"重量法"},{"_id":"6a832b7f884ede9a1b2c54d1","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda powierzchniowa","methodology":"Stężenie rtęci","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie rtęci","reference":"PN-EN ISO 12846:2012","norm_bases":["PN-EN ISO 12846:2012"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda powierzchniowa Stężenie rtęci PN-EN ISO 12846:2012 Woda powierzchniowa Stezenie rteci PN-EN ISO 12846:2012","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","search_en":"Surface water Mercury concentration PN-EN ISO 12846:2012","test_object_en":"Surface water","methodology_zh":"汞浓度","search_zh":"地表水 汞浓度 PN-EN ISO 12846:2012","test_object_zh":"地表水"},{"_id":"6a832b7f884ede9a1b2c54d2","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda powierzchniowa","methodology":"","parameters":[{"name":"Zakres","range":"(0,00007 – 0,50) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zakres (0,00007 – 0,50) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"+Ap1:2016-07","norm_bases":["+Ap1:2016-07"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda powierzchniowa Zakres (0,00007 – 0,50) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) +Ap1:2016-07 Woda powierzchniowa Zakres (0,00007 – 0,50) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) +Ap1:2016-07","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,00007 – 0,50) mg/l"}],"search_en":"Surface water Cold vapour atomic absorption spectrometry (CVAAS) Range +Ap1:2016-07","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Surface water","parameters_zh":[{"name":"范围","range":"(0,00007 – 0,50) mg/l"}],"search_zh":"地表水 冷蒸气原子吸收光谱法（CVAAS） 范围 +Ap1:2016-07","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"地表水"},{"_id":"6a832b7f884ede9a1b2c54d3","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda powierzchniowa","methodology":"Stężenie benzo(a)pirenu","parameters":[{"name":"Zakres","range":"(0,00010 – 1,5) μg/I"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie benzo(a)pirenu\nZakres (0,00010 – 1,5) μg/I\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"EFO/PB/49/A:30.04.2025","norm_bases":["EFO/PB/49/A:30.04.2025"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda powierzchniowa Stężenie benzo(a)pirenu\nZakres (0,00010 – 1,5) μg/I\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) EFO/PB/49/A:30.04.2025 Woda powierzchniowa Stezenie benzo(a)pirenu\nZakres (0,00010 – 1,5) μg/I\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) EFO/PB/49/A:30.04.2025","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Benzo(a)pyrene concentration","parameters_en":[{"name":"Range","range":"(0,00010 – 1,5) μg/I"}],"search_en":"Surface water Benzo(a)pyrene concentration Gas chromatography with mass spectrometry detection (GC-MS) Range EFO/PB/49/A:30.04.2025","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Surface water","parameters_zh":[{"name":"范围","range":"(0,00010 – 1,5) μg/I"}],"search_zh":"地表水 苯并(a)芘浓度 气相色谱-质谱法（GC-MS） 范围 EFO/PB/49/A:30.04.2025","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"地表水","methodology_zh":"苯并(a)芘浓度"},{"_id":"6a832b7f884ede9a1b2c54d4","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Wody podziemne","methodology":"Indeks oleju mineralnego (C10-C40, C12-C35, C12-C30)","parameters":[{"name":"Zakres","range":"(0,050 – 100) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego (C10-C40, C12-C35, C12-C30)\nZakres (0,050 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody podziemne Indeks oleju mineralnego (C10-C40, C12-C35, C12-C30)\nZakres (0,050 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Wody podziemne Indeks oleju mineralnego (C10-C40, C12-C35, C12-C30)\nZakres (0,050 – 100) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index (C10-C40, C12-C35, C12-C30)","parameters_en":[{"name":"Range","range":"(0,050 – 100) mg/l"}],"search_en":"Groundwater Mineral oil index (C10-C40, C12-C35, C12-C30) Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Groundwater","parameters_zh":[{"name":"范围","range":"(0,050 – 100) mg/l"}],"search_zh":"地下水 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"地下水"},{"_id":"6a832b7f884ede9a1b2c54d5","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie akryloamidu","parameters":[{"name":"Zakres","range":"(0,040 – 2,0) μg/l"}],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Stężenie akryloamidu\nZakres (0,040 – 2,0) μg/l\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"EFO/PB/29/A:24.05.2024","norm_bases":["EFO/PB/29/A:24.05.2024"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie akryloamidu\nZakres (0,040 – 2,0) μg/l\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) EFO/PB/29/A:24.05.2024 Woda, Woda do spozycia przez ludzi Stezenie akryloamidu\nZakres (0,040 – 2,0) μg/l\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) EFO/PB/29/A:24.05.2024","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acrylamide concentration","parameters_en":[{"name":"Range","range":"(0,040 – 2,0) μg/l"}],"search_en":"Water, Water intended for human consumption Acrylamide concentration Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) Range EFO/PB/29/A:24.05.2024","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,040 – 2,0) μg/l"}],"search_zh":"水、生活饮用水 丙烯酰胺浓度 气相色谱-串联质谱法（GC-MS-MS） 范围 EFO/PB/29/A:24.05.2024","test_object_zh":"水、生活饮用水","technique_zh":"气相色谱-串联质谱法（GC-MS-MS）","methodology_zh":"丙烯酰胺浓度"},{"_id":"6a832b7f884ede9a1b2c54d6","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,100 – 100) mg/l"},{"name":"Stężenie jonu amonowego"},{"name":"Zakres","range":"(0,128 – 130) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (0,100 – 100) mg/l\nStężenie jonu amonowego\nZakres (0,128 – 130) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 11732:2007","norm_bases":["PN-EN ISO 11732:2007"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotu amonowego\nZakres:\nZakres (0,100 – 100) mg/l\nStężenie jonu amonowego\nZakres (0,128 – 130) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 11732:2007 Woda, Woda do spozycia przez ludzi Stezenie azotu amonowego\nZakres:\nZakres (0,100 – 100) mg/l\nStezenie jonu amonowego\nZakres (0,128 – 130) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 11732:2007","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,100 – 100) mg/l"},{"name":"Ammonium ion concentration"},{"name":"Range","range":"(0,128 – 130) mg/l"}],"search_en":"Water, Water intended for human consumption Ammonium nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range Ammonium ion concentration Range PN-EN ISO 11732:2007","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, Water intended for human consumption","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,100 – 100) mg/l"},{"name":"铵离子浓度"},{"name":"范围","range":"(0,128 – 130) mg/l"}],"search_zh":"水、生活饮用水 氨氮浓度 连续流动分析（CFA）分光光度检测法 范围 铵离子浓度 范围 PN-EN ISO 11732:2007","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、生活饮用水"},{"_id":"6a832b7f884ede9a1b2c54d7","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,005 – 0,025) mg/l"},{"name":"Stężenie azotynów"},{"name":"Zakres","range":"(0,016 – 0,082) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres:\nZakres (0,005 – 0,025) mg/l\nStężenie azotynów\nZakres (0,016 – 0,082) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotu azotynowego\nZakres:\nZakres (0,005 – 0,025) mg/l\nStężenie azotynów\nZakres (0,016 – 0,082) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda, Woda do spozycia przez ludzi Stezenie azotu azotynowego\nZakres:\nZakres (0,005 – 0,025) mg/l\nStezenie azotynow\nZakres (0,016 – 0,082) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,005 – 0,025) mg/l"},{"name":"Nitrite concentration"},{"name":"Range","range":"(0,016 – 0,082) mg/l"}],"search_en":"Water, Water intended for human consumption Nitrite nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range Nitrite concentration Range PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, Water intended for human consumption","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,005 – 0,025) mg/l"},{"name":"亚硝酸盐浓度"},{"name":"范围","range":"(0,016 – 0,082) mg/l"}],"search_zh":"水、生活饮用水 亚硝态氮浓度 连续流动分析（CFA）分光光度检测法 范围 亚硝酸盐浓度 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、生活饮用水"},{"_id":"6a832b7f884ede9a1b2c54d8","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie bromianów","parameters":[{"name":"Zakres","range":"(2,0 – 100) μg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie bromianów\nZakres (2,0 – 100) μg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 15061:2003","norm_bases":["PN-EN ISO 15061:2003"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie bromianów\nZakres (2,0 – 100) μg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 15061:2003 Woda, Woda do spozycia przez ludzi Stezenie bromianow\nZakres (2,0 – 100) μg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 15061:2003","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bromate concentration","parameters_en":[{"name":"Range","range":"(2,0 – 100) μg/l"}],"search_en":"Water, Water intended for human consumption Bromate concentration Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 15061:2003","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(2,0 – 100) μg/l"}],"search_zh":"水、生活饮用水 溴酸盐浓度 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 15061:2003","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水","methodology_zh":"溴酸盐浓度"},{"_id":"6a832b7f884ede9a1b2c54d9","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie bromianów","parameters":[{"name":"Zakres","range":"(2,0 – 100) μg/l"}],"technique":"Metoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/Vis)","techniques":["Metoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/Vis)"],"computed":[],"activity":"Stężenie bromianów\nZakres (2,0 – 100) μg/l\nMetoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/Vis)","reference":"PN-EN ISO 11206:2013-07","norm_bases":["PN-EN ISO 11206:2013-07"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie bromianów\nZakres (2,0 – 100) μg/l\nMetoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/Vis) PN-EN ISO 11206:2013-07 Woda, Woda do spozycia przez ludzi Stezenie bromianow\nZakres (2,0 – 100) μg/l\nMetoda chromatografii jonowej z detekcja spektrofotometryczna (IC-UV/Vis) PN-EN ISO 11206:2013-07","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bromate concentration","parameters_en":[{"name":"Range","range":"(2,0 – 100) μg/l"}],"search_en":"Water, Water intended for human consumption Bromate concentration Ion chromatography with spectrophotometric detection (IC-UV/Vis) Range PN-EN ISO 11206:2013-07","technique_en":"Ion chromatography with spectrophotometric detection (IC-UV/Vis)","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(2,0 – 100) μg/l"}],"search_zh":"水、生活饮用水 溴酸盐浓度 离子色谱-分光光度检测法（IC-UV/Vis） 范围 PN-EN ISO 11206:2013-07","test_object_zh":"水、生活饮用水","methodology_zh":"溴酸盐浓度","technique_zh":"离子色谱-分光光度检测法（IC-UV/Vis）"},{"_id":"6a832b7f884ede9a1b2c54da","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chloranów","parameters":[{"name":"Zakres","range":"(0,02 – 1,0) mg/l"},{"name":"Stężenie chlorynów"},{"name":"Zakres","range":"(0,02 – 1,0) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie chloranów\nZakres:\nZakres (0,02 – 1,0) mg/l\nStężenie chlorynów\nZakres (0,02 – 1,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chloranów\nZakres:\nZakres (0,02 – 1,0) mg/l\nStężenie chlorynów\nZakres (0,02 – 1,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-4:2022-08 Woda, Woda do spozycia przez ludzi Stezenie chloranow\nZakres:\nZakres (0,02 – 1,0) mg/l\nStezenie chlorynow\nZakres (0,02 – 1,0) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorate concentration","parameters_en":[{"name":"Range","range":"(0,02 – 1,0) mg/l"},{"name":"Chlorite concentration"},{"name":"Range","range":"(0,02 – 1,0) mg/l"}],"search_en":"Water, Water intended for human consumption Chlorate concentration Ion chromatography with conductometric detection (IC-CD) Range Chlorite concentration Range PN-EN ISO 10304-4:2022-08","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,02 – 1,0) mg/l"},{"name":"亚氯酸盐浓度"},{"name":"范围","range":"(0,02 – 1,0) mg/l"}],"search_zh":"水、生活饮用水 氯酸盐浓度 离子色谱-电导检测法（IC-CD） 范围 亚氯酸盐浓度 范围 PN-EN ISO 10304-4:2022-08","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水","methodology_zh":"氯酸盐浓度"},{"_id":"6a832b7f884ede9a1b2c54db","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Suma chloranów i chlorynów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma chloranów i chlorynów (z obliczeń)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Suma chloranów i chlorynów (z obliczeń) PN-EN ISO 10304-4:2022-08 Woda, Woda do spozycia przez ludzi Suma chloranow i chlorynow (z obliczen) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of chlorates and chlorites (calculated)","search_en":"Water, Water intended for human consumption Sum of chlorates and chlorites (calculated) PN-EN ISO 10304-4:2022-08","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 氯酸盐与亚氯酸盐总量（由计算得出） PN-EN ISO 10304-4:2022-08","test_object_zh":"水、生活饮用水","methodology_zh":"氯酸盐与亚氯酸盐总量（由计算得出）"},{"_id":"6a832b7f884ede9a1b2c54dc","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chromu (VI)","parameters":[{"name":"Zakres","range":"(0,010 – 5,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu (VI)\nZakres (0,010 – 5,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 18412:2007","norm_bases":["PN-EN ISO 18412:2007"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chromu (VI)\nZakres (0,010 – 5,00) mg/l\nMetoda spektrofotometryczna PN-EN ISO 18412:2007 Woda, Woda do spozycia przez ludzi Stezenie chromu (VI)\nZakres (0,010 – 5,00) mg/l\nMetoda spektrofotometryczna PN-EN ISO 18412:2007","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) concentration","parameters_en":[{"name":"Range","range":"(0,010 – 5,00) mg/l"}],"search_en":"Water, Water intended for human consumption Chromium(VI) concentration Spectrophotometric method Range PN-EN ISO 18412:2007","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,010 – 5,00) mg/l"}],"search_zh":"水、生活饮用水 六价铬浓度 分光光度法 范围 PN-EN ISO 18412:2007","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"六价铬浓度"},{"_id":"6a832b7f884ede9a1b2c54dd","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chromu (III) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chromu (III) (z obliczeń)","reference":"PN-EN ISO 18412:2007","norm_bases":["PN-EN ISO 18412:2007"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chromu (III) (z obliczeń) PN-EN ISO 18412:2007 Woda, Woda do spozycia przez ludzi Stezenie chromu (III) (z obliczen) PN-EN ISO 18412:2007","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium (III) concentration (calculated)","search_en":"Water, Water intended for human consumption Chromium (III) concentration (calculated) PN-EN ISO 18412:2007","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 铬(III)浓度（由计算得出） PN-EN ISO 18412:2007","test_object_zh":"水、生活饮用水","methodology_zh":"铬(III)浓度（由计算得出）"},{"_id":"6a832b7f884ede9a1b2c54de","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie epichlorohydryny","parameters":[{"name":"Zakres","range":"(0,030 – 1,20) μg/l"}],"technique":"Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","techniques":["Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)"],"computed":[],"activity":"Stężenie epichlorohydryny\nZakres (0,030 – 1,20) μg/l\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","reference":"EFO/PB/31/A:24.05.2024","norm_bases":["EFO/PB/31/A:24.05.2024"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie epichlorohydryny\nZakres (0,030 – 1,20) μg/l\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS) EFO/PB/31/A:24.05.2024 Woda, Woda do spozycia przez ludzi Stezenie epichlorohydryny\nZakres (0,030 – 1,20) μg/l\nMetoda chromatografii gazowej z technika wylapywania i wyplukiwania (Purge&Trap) i detekcja spektrometria mas (P&T GC-MS) EFO/PB/31/A:24.05.2024","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Epichlorohydrin concentration","parameters_en":[{"name":"Range","range":"(0,030 – 1,20) μg/l"}],"search_en":"Water, Water intended for human consumption Epichlorohydrin concentration Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS) Range EFO/PB/31/A:24.05.2024","technique_en":"Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS)","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,030 – 1,20) μg/l"}],"search_zh":"水、生活饮用水 环氧氯丙烷浓度 吹扫捕集气相色谱-质谱法（P&T GC-MS） 范围 EFO/PB/31/A:24.05.2024","test_object_zh":"水、生活饮用水","technique_zh":"吹扫捕集气相色谱-质谱法（P&T GC-MS）","methodology_zh":"环氧氯丙烷浓度"},{"_id":"6a832b7f884ede9a1b2c54df","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie Mikrocystyna LR","parameters":[{"name":"Zakres","range":"(0,3 – 2) μg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Stężenie Mikrocystyna LR\nZakres (0,3 – 2) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"EFO/PB/39/A:30.04.2025","norm_bases":["EFO/PB/39/A:30.04.2025"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie Mikrocystyna LR\nZakres (0,3 – 2) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) EFO/PB/39/A:30.04.2025 Woda, Woda do spozycia przez ludzi Stezenie Mikrocystyna LR\nZakres (0,3 – 2) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) EFO/PB/39/A:30.04.2025","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microcystin LR concentration","parameters_en":[{"name":"Range","range":"(0,3 – 2) μg/l"}],"search_en":"Water, Water intended for human consumption Microcystin LR concentration High-performance liquid chromatography with diode array detection (HPLC-DAD) Range EFO/PB/39/A:30.04.2025","technique_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD)","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,3 – 2) μg/l"}],"search_zh":"水、生活饮用水 高效液相色谱-二极管阵列检测法（HPLC-DAD） 范围 EFO/PB/39/A:30.04.2025","test_object_zh":"水、生活饮用水","technique_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD）"},{"_id":"6a832b7f884ede9a1b2c54e0","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki oczyszczone","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,02 – 8,0) mg/l"}],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,02 – 8,0) mg/l","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki oczyszczone Stężenie chloru wolnego\nZakres (0,02 – 8,0) mg/l PN-EN ISO 7393-2:2018-04 Woda, Woda do spozycia przez ludzi, Scieki oczyszczone Stezenie chloru wolnego\nZakres (0,02 – 8,0) mg/l PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,02 – 8,0) mg/l"}],"search_en":"Water, Water intended for human consumption, Treated wastewater Free chlorine concentration Range PN-EN ISO 7393-2:2018-04","test_object_en":"Water, Water intended for human consumption, Treated wastewater","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 8,0) mg/l"}],"search_zh":"水、生活饮用水、处理后废水 游离氯浓度 范围 PN-EN ISO 7393-2:2018-04","test_object_zh":"水、生活饮用水、处理后废水"},{"_id":"6a832b7f884ede9a1b2c54e1","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki oczyszczone","methodology":"Stężenie chloru ogólnego (całkowitego)","parameters":[{"name":"Zakres","range":"(0,02 – 8,0) mg/l"}],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloru ogólnego (całkowitego)\nZakres (0,02 – 8,0) mg/l","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki oczyszczone Stężenie chloru ogólnego (całkowitego)\nZakres (0,02 – 8,0) mg/l PN-EN ISO 7393-2:2018-04 Woda, Woda do spozycia przez ludzi, Scieki oczyszczone Stezenie chloru ogolnego (calkowitego)\nZakres (0,02 – 8,0) mg/l PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chlorine concentration","parameters_en":[{"name":"Range","range":"(0,02 – 8,0) mg/l"}],"search_en":"Water, Water intended for human consumption, Treated wastewater Total chlorine concentration Range PN-EN ISO 7393-2:2018-04","test_object_en":"Water, Water intended for human consumption, Treated wastewater","parameters_zh":[{"name":"范围","range":"(0,02 – 8,0) mg/l"}],"search_zh":"水、生活饮用水、处理后废水 总氯浓度 范围 PN-EN ISO 7393-2:2018-04","test_object_zh":"水、生活饮用水、处理后废水","methodology_zh":"总氯浓度"},{"_id":"6a832b7f884ede9a1b2c54e2","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki oczyszczone","methodology":"Stężenie całkowitego chloru pozostałego","parameters":[{"name":"Zakres","range":"(0,03 – 12,0) mg/l HOCl"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie całkowitego chloru pozostałego\nZakres (0,03 – 12,0) mg/l HOCl\nMetoda kolorymetryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki oczyszczone Stężenie całkowitego chloru pozostałego\nZakres (0,03 – 12,0) mg/l HOCl\nMetoda kolorymetryczna PN-EN ISO 7393-2:2018-04 Woda, Woda do spozycia przez ludzi, Scieki oczyszczone Stezenie calkowitego chloru pozostalego\nZakres (0,03 – 12,0) mg/l HOCl\nMetoda kolorymetryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total residual chlorine concentration","parameters_en":[{"name":"Range","range":"(0,03 – 12,0) mg/l HOCl"}],"search_en":"Water, Water intended for human consumption, Treated wastewater Total residual chlorine concentration Colorimetric method Range PN-EN ISO 7393-2:2018-04","technique_en":"Colorimetric method","test_object_en":"Water, Water intended for human consumption, Treated wastewater","parameters_zh":[{"name":"范围","range":"(0,03 – 12,0) mg/l HOCl"}],"search_zh":"水、生活饮用水、处理后废水 比色法 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"比色法","test_object_zh":"水、生活饮用水、处理后废水"},{"_id":"6a832b7f884ede9a1b2c54e3","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki oczyszczone","methodology":"Stężenie chloroamin (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloroamin (z obliczeń)","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki oczyszczone Stężenie chloroamin (z obliczeń) PN-EN ISO 7393-2:2018-04 Woda, Woda do spozycia przez ludzi, Scieki oczyszczone Stezenie chloroamin (z obliczen) PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloramine concentration (calculated)","search_en":"Water, Water intended for human consumption, Treated wastewater Chloramine concentration (calculated) PN-EN ISO 7393-2:2018-04","test_object_en":"Water, Water intended for human consumption, Treated wastewater","search_zh":"水、生活饮用水、处理后废水 PN-EN ISO 7393-2:2018-04","test_object_zh":"水、生活饮用水、处理后废水"},{"_id":"6a832b7f884ede9a1b2c54e4","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki oczyszczone","methodology":"Stężenie chloru związanego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloru związanego (z obliczeń)","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki oczyszczone Stężenie chloru związanego (z obliczeń) PN-EN ISO 7393-2:2018-04 Woda, Woda do spozycia przez ludzi, Scieki oczyszczone Stezenie chloru zwiazanego (z obliczen) PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Combined chlorine concentration (calculated)","search_en":"Water, Water intended for human consumption, Treated wastewater Combined chlorine concentration (calculated) PN-EN ISO 7393-2:2018-04","test_object_en":"Water, Water intended for human consumption, Treated wastewater","methodology_zh":"化合氯浓度（计算值）","search_zh":"水、生活饮用水、处理后废水 化合氯浓度（计算值） PN-EN ISO 7393-2:2018-04","test_object_zh":"水、生活饮用水、处理后废水"},{"_id":"6a832b7f884ede9a1b2c54e5","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 700) mg/l Pt"}],"technique":"Metoda spektrometryczna","techniques":["Metoda spektrometryczna"],"computed":[],"activity":"Barwa\nZakres (5 – 700) mg/l Pt\nMetoda spektrometryczna","reference":"PN-EN ISO 7887:2012 pkt. 6 + AP1:2015-06","norm_bases":["PN-EN ISO 7887:2012 pkt. 6 + AP1:2015-06"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Barwa\nZakres (5 – 700) mg/l Pt\nMetoda spektrometryczna PN-EN ISO 7887:2012 pkt. 6 + AP1:2015-06 Woda, Woda do spozycia przez ludzi, Scieki Barwa\nZakres (5 – 700) mg/l Pt\nMetoda spektrometryczna PN-EN ISO 7887:2012 pkt. 6 + AP1:2015-06","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 700) mg/l Pt"}],"search_en":"Water, Water intended for human consumption, Wastewater Colour Spectrometric method Range PN-EN ISO 7887:2012 pkt. 6 + AP1:2015-06","technique_en":"Spectrometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 700) mg/l Pt"}],"search_zh":"水、生活饮用水、废水 色度 光谱法 范围 PN-EN ISO 7887:2012 pkt. 6 + AP1:2015-06","test_object_zh":"水、生活饮用水、废水","technique_zh":"光谱法"},{"_id":"6a832b7f884ede9a1b2c54e6","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, Woda do spozycia przez ludzi, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1 – 6000) mg/l O2"}],"search_en":"Water, Water intended for human consumption, Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"水、生活饮用水、废水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c54e7","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Woda, Woda do spozycia przez ludzi, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1 – 6000) mg/l O2"}],"search_en":"Water, Water intended for human consumption, Wastewater Biochemical oxygen demand Optical method BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"水、生活饮用水、废水 生化需氧量 光学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c54e8","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT7"},{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT7\nZakres (1 – 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT7\nZakres (1 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Woda, Woda do spozycia przez ludzi, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT7\nZakres (1 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD7"},{"name":"Range","range":"(1 – 6000) mg/l O2"}],"search_en":"Water, Water intended for human consumption, Wastewater Biochemical oxygen demand Optical method BOD7 Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT7"},{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"水、生活饮用水、废水 生化需氧量 光学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c54e9","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(5,0 – 20000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (5,0 – 20000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN ISO 15705:2005","norm_bases":["PN ISO 15705:2005"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (5,0 – 20000) mg/l O2\nMetoda spektrofotometryczna PN ISO 15705:2005 Woda, Woda do spozycia przez ludzi, Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (5,0 – 20000) mg/l O2\nMetoda spektrofotometryczna PN ISO 15705:2005","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(5,0 – 20000) mg/l O2"}],"search_en":"Water, Water intended for human consumption, Wastewater Chemical oxygen demand Spectrophotometric method COD-Cr Range PN ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(5,0 – 20000) mg/l O2"}],"search_zh":"水、生活饮用水、废水 化学需氧量（COD） 分光光度法 化学需氧量（COD-Cr） 范围 PN ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a832b7f884ede9a1b2c54ea","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZT-Mn"},{"name":"Zakres","range":"(2,0 – 800) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Mn\nZakres (2,0 – 800) mg/l O2\nMetoda miareczkowa","reference":"PN-85/C-04578/02","norm_bases":["PN-85/C-04578/02"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Mn\nZakres (2,0 – 800) mg/l O2\nMetoda miareczkowa PN-85/C-04578/02 Woda, Woda do spozycia przez ludzi, Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Mn\nZakres (2,0 – 800) mg/l O2\nMetoda miareczkowa PN-85/C-04578/02","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"COD-Mn"},{"name":"Range","range":"(2,0 – 800) mg/l O2"}],"search_en":"Water, Water intended for human consumption, Wastewater Chemical oxygen demand Titrimetric method COD-Mn Range PN-85/C-04578/02","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"ChZT-Mn"},{"name":"范围","range":"(2,0 – 800) mg/l O2"}],"search_zh":"水、生活饮用水、废水 化学需氧量（COD） 滴定法 范围 PN-85/C-04578/02","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a832b7f884ede9a1b2c54eb","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,5 – 800) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,5 – 800) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Indeks nadmanganianowy\nZakres (0,5 – 800) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, Woda do spozycia przez ludzi, Scieki Indeks nadmanganianowy\nZakres (0,5 – 800) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,5 – 800) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,5 – 800) mg/l"}],"search_zh":"水、生活饮用水、废水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c54ec","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Kwasowość ogólna","parameters":[{"name":"Zakres","range":"(0,10 – 50) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość ogólna\nZakres (0,10 – 50) mmol/l\nMetoda miareczkowa","reference":"PN-90/C-04540/02","norm_bases":["PN-90/C-04540/02"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Kwasowość ogólna\nZakres (0,10 – 50) mmol/l\nMetoda miareczkowa PN-90/C-04540/02 Woda, Woda do spozycia przez ludzi, Scieki Kwasowosc ogolna\nZakres (0,10 – 50) mmol/l\nMetoda miareczkowa PN-90/C-04540/02","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total acidity","parameters_en":[{"name":"Range","range":"(0,10 – 50) mmol/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Total acidity Titrimetric method Range PN-90/C-04540/02","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 50) mmol/l"}],"search_zh":"水、生活饮用水、废水 总酸度 滴定法 范围 PN-90/C-04540/02","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"总酸度"},{"_id":"6a832b7f884ede9a1b2c54ed","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Kwaśne węglany/wodorowęglany, Węglany (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kwaśne węglany/wodorowęglany, Węglany (z obliczeń)","reference":"PB/FCH/34/B:30.03.2012","norm_bases":["PB/FCH/34/B:30.03.2012"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Kwaśne węglany/wodorowęglany, Węglany (z obliczeń) PB/FCH/34/B:30.03.2012 Woda, Woda do spozycia przez ludzi, Scieki Kwasne weglany/wodoroweglany, Weglany (z obliczen) PB/FCH/34/B:30.03.2012","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acid carbonates/bicarbonates, Carbonates (calculated)","search_en":"Water, Water intended for human consumption, Wastewater Acid carbonates/bicarbonates, Carbonates (calculated) PB/FCH/34/B:30.03.2012","test_object_en":"Water, Water intended for human consumption, Wastewater","search_zh":"水、生活饮用水、废水 PB/FCH/34/B:30.03.2012","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c54ee","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,2 – 800) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,2 – 800) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Mętność\nZakres (0,2 – 800) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi, Scieki Metnosc\nZakres (0,2 – 800) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,2 – 800) NTU"}],"search_en":"Water, Water intended for human consumption, Wastewater Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,2 – 800) NTU"}],"search_zh":"水、生活饮用水、废水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c54ef","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi, Scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Water, Water intended for human consumption, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、生活饮用水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c54f0","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 – 99990) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 99990) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Przewodność elektryczna właściwa\nZakres (10 – 99990) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi, Scieki Przewodnosc elektryczna wlasciwa\nZakres (10 – 99990) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10 – 99990) μS/cm"}],"search_en":"Water, Water intended for human consumption, Wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 99990) μS/cm"}],"search_zh":"水、生活饮用水、废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c54f1","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie alkilofenoli","parameters":[{"name":"Zakres","range":"4-Nonylofenol (0,02 – 0,20) μg/l"},{"name":"4-tert-Oktylofenol","range":"(0,005 – 0,20) μg/l"}],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Stężenie alkilofenoli\nZakres:\nZakres 4-Nonylofenol (0,02 – 0,20) μg/l\n4-tert-Oktylofenol (0,005 – 0,20) μg/l\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"PN-EN ISO 18857-1:2009","norm_bases":["PN-EN ISO 18857-1:2009"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie alkilofenoli\nZakres:\nZakres 4-Nonylofenol (0,02 – 0,20) μg/l\n4-tert-Oktylofenol (0,005 – 0,20) μg/l\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) PN-EN ISO 18857-1:2009 Woda, Woda do spozycia przez ludzi, Scieki Stezenie alkilofenoli\nZakres:\nZakres 4-Nonylofenol (0,02 – 0,20) μg/l\n4-tert-Oktylofenol (0,005 – 0,20) μg/l\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) PN-EN ISO 18857-1:2009","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Alkylphenol concentration","parameters_en":[{"name":"Range","range":"4-Nonylofenol (0,02 – 0,20) μg/l"},{"name":"4-tert-Octylphenol","range":"(0,005 – 0,20) μg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Alkylphenol concentration Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) Range 4-tert-Octylphenol PN-EN ISO 18857-1:2009","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"4-Nonylofenol (0,02 – 0,20) μg/l"},{"name":"4-tert-Oktylofenol","range":"(0,005 – 0,20) μg/l"}],"search_zh":"水、生活饮用水、废水 气相色谱-串联质谱法（GC-MS-MS） 范围 PN-EN ISO 18857-1:2009","test_object_zh":"水、生活饮用水、废水","technique_zh":"气相色谱-串联质谱法（GC-MS-MS）"},{"_id":"6a832b7f884ede9a1b2c54f2","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie anionów","parameters":[{"name":"jodki","range":"(0,25 – 50) mg/l"},{"name":"rodanki","range":"(0,50 – 150) mg/l"},{"name":"siarczyny","range":"(0,50 – 150) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\njodki (0,25 – 50) mg/l\nrodanki (0,50 – 150) mg/l\nsiarczyny (0,50 – 150) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-3:2001","norm_bases":["PN-EN ISO 10304-3:2001"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie anionów\nZakres:\njodki (0,25 – 50) mg/l\nrodanki (0,50 – 150) mg/l\nsiarczyny (0,50 – 150) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-3:2001 Woda, Woda do spozycia przez ludzi, Scieki Stezenie anionow\nZakres:\njodki (0,25 – 50) mg/l\nrodanki (0,50 – 150) mg/l\nsiarczyny (0,50 – 150) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-3:2001","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"iodides","range":"(0,25 – 50) mg/l"},{"name":"thiocyanates","range":"(0,50 – 150) mg/l"},{"name":"sulphites","range":"(0,50 – 150) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) iodides thiocyanates sulphites PN-EN ISO 10304-3:2001","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"阴离子浓度","search_zh":"水、生活饮用水、废水 阴离子浓度 离子色谱-电导检测法（IC-CD） PN-EN ISO 10304-3:2001","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c54f3","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie anionów","parameters":[{"name":"azotyny","range":"(0,025 – 2,50) mg/l"},{"name":"azot azotynowy","range":"(0,008 – 0,80) mg/l"},{"name":"azotany","range":"(1,0 – 100) mg/l"},{"name":"azot azotanowy","range":"(0,22 – 22,5) mg/l"},{"name":"fosforany","range":"(0,10 – 10) mg/l"},{"name":"siarczany","range":"(2,0 – 10000) mg/l"},{"name":"chlorki","range":"(2,0 – 10000) mg/l"},{"name":"bromki","range":"(0,10 – 10) mg/l"},{"name":"fluorki","range":"(0,10 – 10) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nazotyny (0,025 – 2,50) mg/l\nazot azotynowy (0,008 – 0,80) mg/l\nazotany (1,0 – 100) mg/l\nazot azotanowy (0,22 – 22,5) mg/l\nfosforany (0,10 – 10) mg/l\nsiarczany (2,0 – 10000) mg/l\nchlorki (2,0 – 10000) mg/l\nbromki (0,10 – 10) mg/l\nfluorki (0,10 – 10) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009","norm_bases":["PN-EN ISO 10304-1:2009"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie anionów\nZakres:\nazotyny (0,025 – 2,50) mg/l\nazot azotynowy (0,008 – 0,80) mg/l\nazotany (1,0 – 100) mg/l\nazot azotanowy (0,22 – 22,5) mg/l\nfosforany (0,10 – 10) mg/l\nsiarczany (2,0 – 10000) mg/l\nchlorki (2,0 – 10000) mg/l\nbromki (0,10 – 10) mg/l\nfluorki (0,10 – 10) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 Woda, Woda do spozycia przez ludzi, Scieki Stezenie anionow\nZakres:\nazotyny (0,025 – 2,50) mg/l\nazot azotynowy (0,008 – 0,80) mg/l\nazotany (1,0 – 100) mg/l\nazot azotanowy (0,22 – 22,5) mg/l\nfosforany (0,10 – 10) mg/l\nsiarczany (2,0 – 10000) mg/l\nchlorki (2,0 – 10000) mg/l\nbromki (0,10 – 10) mg/l\nfluorki (0,10 – 10) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"nitrites","range":"(0,025 – 2,50) mg/l"},{"name":"nitrite nitrogen","range":"(0,008 – 0,80) mg/l"},{"name":"nitrates","range":"(1,0 – 100) mg/l"},{"name":"nitrate nitrogen","range":"(0,22 – 22,5) mg/l"},{"name":"phosphates","range":"(0,10 – 10) mg/l"},{"name":"sulfates","range":"(2,0 – 10000) mg/l"},{"name":"chlorides","range":"(2,0 – 10000) mg/l"},{"name":"bromides","range":"(0,10 – 10) mg/l"},{"name":"fluorides","range":"(0,10 – 10) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) nitrites nitrite nitrogen nitrates nitrate nitrogen phosphates sulfates chlorides bromides fluorides PN-EN ISO 10304-1:2009","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"阴离子浓度","search_zh":"水、生活饮用水、废水 阴离子浓度 离子色谱-电导检测法（IC-CD） 亚硝酸盐 亚硝酸盐氮 硝酸盐 硝酸盐氮 磷酸盐 硫酸盐 氯化物 溴化物 氟化物 PN-EN ISO 10304-1:2009","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水、废水","parameters_zh":[{"name":"亚硝酸盐","range":"(0,025 – 2,50) mg/l"},{"name":"亚硝酸盐氮","range":"(0,008 – 0,80) mg/l"},{"name":"硝酸盐","range":"(1,0 – 100) mg/l"},{"name":"硝酸盐氮","range":"(0,22 – 22,5) mg/l"},{"name":"磷酸盐","range":"(0,10 – 10) mg/l"},{"name":"硫酸盐","range":"(2,0 – 10000) mg/l"},{"name":"氯化物","range":"(2,0 – 10000) mg/l"},{"name":"溴化物","range":"(0,10 – 10) mg/l"},{"name":"氟化物","range":"(0,10 – 10) mg/l"}]},{"_id":"6a832b7f884ede9a1b2c54f4","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,20 – 100) mg/l"},{"name":"Stężenie azotanów"},{"name":"Zakres","range":"(0,89 – 445) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres:\nZakres (0,20 – 100) mg/l\nStężenie azotanów\nZakres (0,89 – 445) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotu azotanowego\nZakres:\nZakres (0,20 – 100) mg/l\nStężenie azotanów\nZakres (0,89 – 445) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotu azotanowego\nZakres:\nZakres (0,20 – 100) mg/l\nStezenie azotanow\nZakres (0,89 – 445) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,20 – 100) mg/l"},{"name":"Nitrate concentration"},{"name":"Range","range":"(0,89 – 445) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Nitrate nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range Nitrate concentration Range PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 100) mg/l"},{"name":"硝酸盐浓度"},{"name":"范围","range":"(0,89 – 445) mg/l"}],"search_zh":"水、生活饮用水、废水 硝态氮浓度 连续流动分析（CFA）分光光度检测法 范围 硝酸盐浓度 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c54f5","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,020 – 2,50) mg/l"},{"name":"Stężenie azotynów"},{"name":"Zakres","range":"(0,066 – 8,25) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres:\nZakres (0,020 – 2,50) mg/l\nStężenie azotynów\nZakres (0,066 – 8,25) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotu azotynowego\nZakres:\nZakres (0,020 – 2,50) mg/l\nStężenie azotynów\nZakres (0,066 – 8,25) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotu azotynowego\nZakres:\nZakres (0,020 – 2,50) mg/l\nStezenie azotynow\nZakres (0,066 – 8,25) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,020 – 2,50) mg/l"},{"name":"Nitrite concentration"},{"name":"Range","range":"(0,066 – 8,25) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Nitrite nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range Nitrite concentration Range PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 2,50) mg/l"},{"name":"亚硝酸盐浓度"},{"name":"范围","range":"(0,066 – 8,25) mg/l"}],"search_zh":"水、生活饮用水、废水 亚硝态氮浓度 连续流动分析（CFA）分光光度检测法 范围 亚硝酸盐浓度 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c54f6","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie bromowanych difenyloeterów","parameters":[{"name":"(Kongenery","range":"28, 47, 99, 100,153,154)"},{"name":"Zakres","range":"(0,002 – 10,0) μg/l"},{"name":"Suma z obliczeń"}],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Stężenie bromowanych difenyloeterów\nZakres:\n(Kongenery 28, 47, 99, 100,153,154)\nZakres (0,002 – 10,0) μg/l\nSuma z obliczeń\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"PN-EN 16694:2016-01","norm_bases":["PN-EN 16694:2016-01"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie bromowanych difenyloeterów\nZakres:\n(Kongenery 28, 47, 99, 100,153,154)\nZakres (0,002 – 10,0) μg/l\nSuma z obliczeń\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) PN-EN 16694:2016-01 Woda, Woda do spozycia przez ludzi, Scieki Stezenie bromowanych difenyloeterow\nZakres:\n(Kongenery 28, 47, 99, 100,153,154)\nZakres (0,002 – 10,0) μg/l\nSuma z obliczen\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) PN-EN 16694:2016-01","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Brominated diphenyl ethers concentration","parameters_en":[{"name":"(Congeners","range":"28, 47, 99, 100,153,154)"},{"name":"Range","range":"(0,002 – 10,0) μg/l"},{"name":"Sum calculated"}],"search_en":"Water, Water intended for human consumption, Wastewater Brominated diphenyl ethers concentration Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) (Congeners Range Sum calculated PN-EN 16694:2016-01","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"(Kongenery","range":"28, 47, 99, 100,153,154)"},{"name":"范围","range":"(0,002 – 10,0) μg/l"},{"name":"Suma z obliczeń"}],"search_zh":"水、生活饮用水、废水 气相色谱-串联质谱法（GC-MS-MS） 范围 PN-EN 16694:2016-01","test_object_zh":"水、生活饮用水、废水","technique_zh":"气相色谱-串联质谱法（GC-MS-MS）"},{"_id":"6a832b7f884ede9a1b2c54f7","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(2 – 200000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chlorków\nZakres (2 – 200000) mg/l\nMetoda spektrofotometryczna","reference":"PB/FCH/102/A:01.07.2020","norm_bases":["PB/FCH/102/A:01.07.2020"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie chlorków\nZakres (2 – 200000) mg/l\nMetoda spektrofotometryczna PB/FCH/102/A:01.07.2020 Woda, Woda do spozycia przez ludzi, Scieki Stezenie chlorkow\nZakres (2 – 200000) mg/l\nMetoda spektrofotometryczna PB/FCH/102/A:01.07.2020","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(2 – 200000) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Chloride concentration Spectrophotometric method Range PB/FCH/102/A:01.07.2020","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(2 – 200000) mg/l"}],"search_zh":"水、生活饮用水、废水 氯化物浓度 分光光度法 范围 PB/FCH/102/A:01.07.2020","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c54f8","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 20000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 20000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie chlorków\nZakres (5,0 – 20000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Woda do spozycia przez ludzi, Scieki Stezenie chlorkow\nZakres (5,0 – 20000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 20000) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 20000) mg/l"}],"search_zh":"水、生活饮用水、废水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c54f9","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie cyjanków wolnych i ogólnych","parameters":[{"name":"Zakres","range":"(0,0050 – 10) mg/l"},{"name":"Stężenie cyjanków związanych (z obliczeń)"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną.","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną."],"computed":[],"activity":"Stężenie cyjanków wolnych i ogólnych\nZakres:\nZakres (0,0050 – 10) mg/l\nStężenie cyjanków związanych (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną.","reference":"PN-EN ISO 14403-2:2012","norm_bases":["PN-EN ISO 14403-2:2012"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie cyjanków wolnych i ogólnych\nZakres:\nZakres (0,0050 – 10) mg/l\nStężenie cyjanków związanych (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną. PN-EN ISO 14403-2:2012 Woda, Woda do spozycia przez ludzi, Scieki Stezenie cyjankow wolnych i ogolnych\nZakres:\nZakres (0,0050 – 10) mg/l\nStezenie cyjankow zwiazanych (z obliczen)\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna. PN-EN ISO 14403-2:2012","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free and total cyanide concentration","parameters_en":[{"name":"Range","range":"(0,0050 – 10) mg/l"},{"name":"Combined cyanide concentration (calculated)"}],"search_en":"Water, Water intended for human consumption, Wastewater Free and total cyanide concentration Continuous flow analysis (CFA) with spectrophotometric detection. Range Combined cyanide concentration (calculated) PN-EN ISO 14403-2:2012","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection.","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,0050 – 10) mg/l"},{"name":"络合氰化物浓度（由计算得出）"}],"search_zh":"水、生活饮用水、废水 游离氰化物与总氰化物浓度 范围 络合氰化物浓度（由计算得出） PN-EN ISO 14403-2:2012","test_object_zh":"水、生活饮用水、废水","methodology_zh":"游离氰化物与总氰化物浓度"},{"_id":"6a832b7f884ede9a1b2c54fa","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie detergentów anionowych (anionowych substancji powierzchniowo czynnych – ASPC)","parameters":[{"name":"Zakres","range":"(0,05 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie detergentów anionowych (anionowych substancji powierzchniowo czynnych – ASPC)\nZakres (0,05 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 903:2002","norm_bases":["PN-EN 903:2002"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie detergentów anionowych (anionowych substancji powierzchniowo czynnych – ASPC)\nZakres (0,05 – 50,0) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002 Woda, Woda do spozycia przez ludzi, Scieki Stezenie detergentow anionowych (anionowych substancji powierzchniowo czynnych – ASPC)\nZakres (0,05 – 50,0) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anionic detergent concentration (anionic surfactants – ASPC)","parameters_en":[{"name":"Range","range":"(0,05 – 50,0) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Anionic detergent concentration (anionic surfactants – ASPC) Spectrophotometric method Range PN-EN 903:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,05 – 50,0) mg/l"}],"search_zh":"水、生活饮用水、废水 阴离子洗涤剂（阴离子表面活性物质 ASPC）浓度 分光光度法 范围 PN-EN 903:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"阴离子洗涤剂（阴离子表面活性物质 ASPC）浓度"},{"_id":"6a832b7f884ede9a1b2c54fb","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie detergentów niejonowych (niejonowych substancji powierzchniowo czynnych – NSPC)","parameters":[{"name":"Zakres","range":"(0,20 – 300) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie detergentów niejonowych (niejonowych substancji powierzchniowo czynnych – NSPC)\nZakres (0,20 – 300) mg/l\nMetoda spektrofotometryczna","reference":"PB/FCH/72/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 333","norm_bases":["PB/FCH/72/A:10.04.2012","na podstawie testu kuwetowego HACH Lange nr LCK 333"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie detergentów niejonowych (niejonowych substancji powierzchniowo czynnych – NSPC)\nZakres (0,20 – 300) mg/l\nMetoda spektrofotometryczna PB/FCH/72/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 333 Woda, Woda do spozycia przez ludzi, Scieki Stezenie detergentow niejonowych (niejonowych substancji powierzchniowo czynnych – NSPC)\nZakres (0,20 – 300) mg/l\nMetoda spektrofotometryczna PB/FCH/72/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 333","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Non-ionic detergent concentration (non-ionic surfactants – NSPC)","parameters_en":[{"name":"Range","range":"(0,20 – 300) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Non-ionic detergent concentration (non-ionic surfactants – NSPC) Spectrophotometric method Range PB/FCH/72/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 333","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,20 – 300) mg/l"}],"search_zh":"水、生活饮用水、废水 分光光度法 范围 PB/FCH/72/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 333","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c54fc","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie fosforanów","parameters":[{"name":"Zakres","range":"(0,05 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforanów\nZakres (0,05 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie fosforanów\nZakres (0,05 – 200) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010 Woda, Woda do spozycia przez ludzi, Scieki Stezenie fosforanow\nZakres (0,05 – 200) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphate concentration","parameters_en":[{"name":"Range","range":"(0,05 – 200) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Phosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,05 – 200) mg/l"}],"search_zh":"水、生活饮用水、废水 磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"磷酸盐浓度"},{"_id":"6a832b7f884ede9a1b2c54fd","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie krzemionki zdysocjowanej","parameters":[{"name":"Zakres","range":"(0,5 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie krzemionki zdysocjowanej\nZakres (0,5 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-71/C-04567/02","norm_bases":["PN-71/C-04567/02"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie krzemionki zdysocjowanej\nZakres (0,5 – 100) mg/l\nMetoda spektrofotometryczna PN-71/C-04567/02 Woda, Woda do spozycia przez ludzi, Scieki Stezenie krzemionki zdysocjowanej\nZakres (0,5 – 100) mg/l\nMetoda spektrofotometryczna PN-71/C-04567/02","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissociated silica concentration","parameters_en":[{"name":"Range","range":"(0,5 – 100) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Dissociated silica concentration Spectrophotometric method Range PN-71/C-04567/02","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,5 – 100) mg/l"}],"search_zh":"水、生活饮用水、废水 解离二氧化硅浓度 分光光度法 范围 PN-71/C-04567/02","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"解离二氧化硅浓度"},{"_id":"6a832b7f884ede9a1b2c54fe","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie krzemionki (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie krzemionki (z obliczeń)","reference":"PB/I/13/F:01.10.2021","norm_bases":["PB/I/13/F:01.10.2021"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie krzemionki (z obliczeń) PB/I/13/F:01.10.2021 Woda, Woda do spozycia przez ludzi, Scieki Stezenie krzemionki (z obliczen) PB/I/13/F:01.10.2021","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Silica concentration (calculated)","search_en":"Water, Water intended for human consumption, Wastewater Silica concentration (calculated) PB/I/13/F:01.10.2021","test_object_en":"Water, Water intended for human consumption, Wastewater","search_zh":"水、生活饮用水、废水 PB/I/13/F:01.10.2021","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c54ff","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie lotnych węglowodorów aromatycznych (BTX)","parameters":[{"name":"benzen","range":"(1,0 – 5000) μg/l"},{"name":"etylobenzen","range":"(1,0 – 5000) μg/l"},{"name":"toluen","range":"(1,0 – 5000) μg/l"},{"name":"o-ksylen","range":"(1,0 – 5000) μg/l"},{"name":"m+p ksyleny","range":"(1,0 – 10000) μg/l"},{"name":"suma ksylenów","range":"(1,0 – 15000) μg/l"},{"name":"styren","range":"(1,0 – 1000) μg/l"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Stężenie lotnych węglowodorów aromatycznych (BTX)\nZakres:\nbenzen (1,0 – 5000) μg/l\netylobenzen (1,0 – 5000) μg/l\ntoluen (1,0 – 5000) μg/l\no-ksylen (1,0 – 5000) μg/l\nm+p ksyleny (1,0 – 10000) μg/l\nsuma ksylenów (1,0 – 15000) μg/l\nstyren (1,0 – 1000) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PN-ISO 11423-1:2002","norm_bases":["PN-ISO 11423-1:2002"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie lotnych węglowodorów aromatycznych (BTX)\nZakres:\nbenzen (1,0 – 5000) μg/l\netylobenzen (1,0 – 5000) μg/l\ntoluen (1,0 – 5000) μg/l\no-ksylen (1,0 – 5000) μg/l\nm+p ksyleny (1,0 – 10000) μg/l\nsuma ksylenów (1,0 – 15000) μg/l\nstyren (1,0 – 1000) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID) PN-ISO 11423-1:2002 Woda, Woda do spozycia przez ludzi, Scieki Stezenie lotnych weglowodorow aromatycznych (BTX)\nZakres:\nbenzen (1,0 – 5000) μg/l\netylobenzen (1,0 – 5000) μg/l\ntoluen (1,0 – 5000) μg/l\no-ksylen (1,0 – 5000) μg/l\nm+p ksyleny (1,0 – 10000) μg/l\nsuma ksylenow (1,0 – 15000) μg/l\nstyren (1,0 – 1000) μg/l\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej z detekcja plomieniowo-jonizacyjna (HS-GC-FID) PN-ISO 11423-1:2002","categories":["water"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile aromatic hydrocarbons (BTX) concentration","parameters_en":[{"name":"benzene","range":"(1,0 – 5000) μg/l"},{"name":"ethylbenzene","range":"(1,0 – 5000) μg/l"},{"name":"toluene","range":"(1,0 – 5000) μg/l"},{"name":"o-xylene","range":"(1,0 – 5000) μg/l"},{"name":"m+p xylenes","range":"(1,0 – 10000) μg/l"},{"name":"sum of xylenes","range":"(1,0 – 15000) μg/l"},{"name":"styrene","range":"(1,0 – 1000) μg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Volatile aromatic hydrocarbons (BTX) concentration Headspace gas chromatography with flame ionization detection (HS-GC-FID) benzene ethylbenzene toluene o-xylene m+p xylenes sum of xylenes styrene PN-ISO 11423-1:2002","technique_en":"Headspace gas chromatography with flame ionization detection (HS-GC-FID)","test_object_en":"Water, Water intended for human consumption, Wastewater","search_zh":"水、生活饮用水、废水 挥发性芳香烃（BTX）浓度 顶空气相色谱-火焰离子化检测法（HS-GC-FID） 苯 乙苯 甲苯 邻二甲苯 二甲苯总量 苯乙烯 PN-ISO 11423-1:2002","test_object_zh":"水、生活饮用水、废水","parameters_zh":[{"name":"苯","range":"(1,0 – 5000) μg/l"},{"name":"乙苯","range":"(1,0 – 5000) μg/l"},{"name":"甲苯","range":"(1,0 – 5000) μg/l"},{"name":"邻二甲苯","range":"(1,0 – 5000) μg/l"},{"name":"m+p ksyleny","range":"(1,0 – 10000) μg/l"},{"name":"二甲苯总量","range":"(1,0 – 15000) μg/l"},{"name":"苯乙烯","range":"(1,0 – 1000) μg/l"}],"technique_zh":"顶空气相色谱-火焰离子化检测法（HS-GC-FID）","methodology_zh":"挥发性芳香烃（BTX）浓度"},{"_id":"6a832b7f884ede9a1b2c5500","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Suma BTX (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma BTX (z obliczeń)","reference":"PN-ISO 11423-1:2002","norm_bases":["PN-ISO 11423-1:2002"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Suma BTX (z obliczeń) PN-ISO 11423-1:2002 Woda, Woda do spozycia przez ludzi, Scieki Suma BTX (z obliczen) PN-ISO 11423-1:2002","categories":["water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of BTX (calculated)","search_en":"Water, Water intended for human consumption, Wastewater Sum of BTX (calculated) PN-ISO 11423-1:2002","test_object_en":"Water, Water intended for human consumption, Wastewater","search_zh":"水、生活饮用水、废水 BTX 总量（由计算得出） PN-ISO 11423-1:2002","test_object_zh":"水、生活饮用水、废水","methodology_zh":"BTX 总量（由计算得出）"},{"_id":"6a832b7f884ede9a1b2c5501","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie ogólnego węgla organicznego (OWO) /","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie ogólnego węgla organicznego (OWO) /","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie ogólnego węgla organicznego (OWO) / PN-EN 1484:1999 Woda, Woda do spozycia przez ludzi, Scieki Stezenie ogolnego wegla organicznego (OWO) / PN-EN 1484:1999","categories":["water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon (TOC) concentration /","search_en":"Water, Water intended for human consumption, Wastewater Total organic carbon (TOC) concentration / PN-EN 1484:1999","test_object_en":"Water, Water intended for human consumption, Wastewater","search_zh":"水、生活饮用水、废水 PN-EN 1484:1999","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c5502","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Rozpuszczonego węgla organicznego (RWO)","parameters":[{"name":"Zakres","range":"(1,50 – 2000) mg/l"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Rozpuszczonego węgla organicznego (RWO)\nZakres (1,50 – 2000) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Rozpuszczonego węgla organicznego (RWO)\nZakres (1,50 – 2000) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999 Woda, Woda do spozycia przez ludzi, Scieki Rozpuszczonego wegla organicznego (RWO)\nZakres (1,50 – 2000) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999","categories":["water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved organic carbon (DOC)","parameters_en":[{"name":"Range","range":"(1,50 – 2000) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Dissolved organic carbon (DOC) Spectrometry method in the infrared range IR Range PN-EN 1484:1999","technique_en":"Spectrometry method in the infrared range IR","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(1,50 – 2000) mg/l"}],"search_zh":"水、生活饮用水、废水 红外光谱法 IR 范围 PN-EN 1484:1999","test_object_zh":"水、生活饮用水、废水","technique_zh":"红外光谱法 IR"},{"_id":"6a832b7f884ede9a1b2c5503","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie pestycydów","parameters":[{"name":"Atrazyna","range":"(0,01 – 1,00) μg/l"},{"name":"Diuron","range":"(0,01 – 1,00) μg/l"},{"name":"Izoproturon","range":"(0,01 – 1,00) μg/l"},{"name":"Symazyna","range":"(0,01 – 1,00) μg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Stężenie pestycydów\nZakres:\nAtrazyna (0,01 – 1,00) μg/l\nDiuron (0,01 – 1,00) μg/l\nIzoproturon (0,01 – 1,00) μg/l\nSymazyna (0,01 – 1,00) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"PN-EN ISO 11369:2002","norm_bases":["PN-EN ISO 11369:2002"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie pestycydów\nZakres:\nAtrazyna (0,01 – 1,00) μg/l\nDiuron (0,01 – 1,00) μg/l\nIzoproturon (0,01 – 1,00) μg/l\nSymazyna (0,01 – 1,00) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) PN-EN ISO 11369:2002 Woda, Woda do spozycia przez ludzi, Scieki Stezenie pestycydow\nZakres:\nAtrazyna (0,01 – 1,00) μg/l\nDiuron (0,01 – 1,00) μg/l\nIzoproturon (0,01 – 1,00) μg/l\nSymazyna (0,01 – 1,00) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) PN-EN ISO 11369:2002","categories":["water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pesticide concentration","parameters_en":[{"name":"Atrazine","range":"(0,01 – 1,00) μg/l"},{"name":"Diuron","range":"(0,01 – 1,00) μg/l"},{"name":"Isoproturon","range":"(0,01 – 1,00) μg/l"},{"name":"Simazine","range":"(0,01 – 1,00) μg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Pesticide concentration High-performance liquid chromatography with diode array detection (HPLC-DAD) Atrazine Diuron Isoproturon Simazine PN-EN ISO 11369:2002","technique_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD)","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"农药浓度","search_zh":"水、生活饮用水、废水 农药浓度 高效液相色谱-二极管阵列检测法（HPLC-DAD） 莠去津 PN-EN ISO 11369:2002","test_object_zh":"水、生活饮用水、废水","technique_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD）","parameters_zh":[{"name":"莠去津","range":"(0,01 – 1,00) μg/l"},{"name":"Diuron","range":"(0,01 – 1,00) μg/l"},{"name":"Izoproturon","range":"(0,01 – 1,00) μg/l"},{"name":"Symazyna","range":"(0,01 – 1,00) μg/l"}]},{"_id":"6a832b7f884ede9a1b2c5504","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie pestycydów fosforoorganicznych:","parameters":[{"name":"azinfos etylowy","range":"(0,05 – 1,00) μg/l"},{"name":"azinfos metylowy","range":"(0,05 – 1,00) μg/l"},{"name":"chlorfenwinfos","range":"(0,05 – 1,00) μg/l"},{"name":"diazynon","range":"(0,05 – 1,00) μg/l"},{"name":"dichlorofos","range":"(0,05 – 1,00) μg/l"},{"name":"fenitrotion","range":"(0,05 – 1,00) μg/l"},{"name":"fention","range":"(0,05 – 1,00) μg/l"},{"name":"malation","range":"(0,05 – 1,00) μg/l"},{"name":"paration etylowy","range":"(0,05 – 1,00) μg/l"},{"name":"paration metylowy","range":"(0,05 – 1,00) μg/l"}],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Stężenie pestycydów fosforoorganicznych:\nZakres:\nazinfos etylowy (0,05 – 1,00) μg/l\nazinfos metylowy (0,05 – 1,00) μg/l\nchlorfenwinfos (0,05 – 1,00) μg/l\ndiazynon (0,05 – 1,00) μg/l\ndichlorofos (0,05 – 1,00) μg/l\nfenitrotion (0,05 – 1,00) μg/l\nfention (0,05 – 1,00) μg/l\nmalation (0,05 – 1,00) μg/l\nparation etylowy (0,05 – 1,00) μg/l\nparation metylowy (0,05 – 1,00) μg/l\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"PN-EN 12918:2004","norm_bases":["PN-EN 12918:2004"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie pestycydów fosforoorganicznych:\nZakres:\nazinfos etylowy (0,05 – 1,00) μg/l\nazinfos metylowy (0,05 – 1,00) μg/l\nchlorfenwinfos (0,05 – 1,00) μg/l\ndiazynon (0,05 – 1,00) μg/l\ndichlorofos (0,05 – 1,00) μg/l\nfenitrotion (0,05 – 1,00) μg/l\nfention (0,05 – 1,00) μg/l\nmalation (0,05 – 1,00) μg/l\nparation etylowy (0,05 – 1,00) μg/l\nparation metylowy (0,05 – 1,00) μg/l\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) PN-EN 12918:2004 Woda, Woda do spozycia przez ludzi, Scieki Stezenie pestycydow fosforoorganicznych:\nZakres:\nazinfos etylowy (0,05 – 1,00) μg/l\nazinfos metylowy (0,05 – 1,00) μg/l\nchlorfenwinfos (0,05 – 1,00) μg/l\ndiazynon (0,05 – 1,00) μg/l\ndichlorofos (0,05 – 1,00) μg/l\nfenitrotion (0,05 – 1,00) μg/l\nfention (0,05 – 1,00) μg/l\nmalation (0,05 – 1,00) μg/l\nparation etylowy (0,05 – 1,00) μg/l\nparation metylowy (0,05 – 1,00) μg/l\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) PN-EN 12918:2004","categories":["water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Organophosphorus pesticide concentration:","parameters_en":[{"name":"azinphos-ethyl","range":"(0,05 – 1,00) μg/l"},{"name":"azinphos-methyl","range":"(0,05 – 1,00) μg/l"},{"name":"chlorfenvinphos","range":"(0,05 – 1,00) μg/l"},{"name":"diazinon","range":"(0,05 – 1,00) μg/l"},{"name":"dichlorvos","range":"(0,05 – 1,00) μg/l"},{"name":"fenitrothion","range":"(0,05 – 1,00) μg/l"},{"name":"fenthion","range":"(0,05 – 1,00) μg/l"},{"name":"malathion","range":"(0,05 – 1,00) μg/l"},{"name":"ethyl parathion","range":"(0,05 – 1,00) μg/l"},{"name":"methyl parathion","range":"(0,05 – 1,00) μg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Organophosphorus pesticide concentration: Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) azinphos-ethyl azinphos-methyl chlorfenvinphos diazinon dichlorvos fenitrothion fenthion malathion ethyl parathion methyl parathion PN-EN 12918:2004","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","test_object_en":"Water, Water intended for human consumption, Wastewater","search_zh":"水、生活饮用水、废水 气相色谱-串联质谱法（GC-MS-MS） 毒虫畏 二嗪农 杀螟硫磷 倍硫磷 马拉硫磷 对硫磷 甲基对硫磷 PN-EN 12918:2004","test_object_zh":"水、生活饮用水、废水","technique_zh":"气相色谱-串联质谱法（GC-MS-MS）","parameters_zh":[{"name":"azinfos etylowy","range":"(0,05 – 1,00) μg/l"},{"name":"azinfos metylowy","range":"(0,05 – 1,00) μg/l"},{"name":"毒虫畏","range":"(0,05 – 1,00) μg/l"},{"name":"二嗪农","range":"(0,05 – 1,00) μg/l"},{"name":"dichlorofos","range":"(0,05 – 1,00) μg/l"},{"name":"杀螟硫磷","range":"(0,05 – 1,00) μg/l"},{"name":"倍硫磷","range":"(0,05 – 1,00) μg/l"},{"name":"马拉硫磷","range":"(0,05 – 1,00) μg/l"},{"name":"对硫磷","range":"(0,05 – 1,00) μg/l"},{"name":"甲基对硫磷","range":"(0,05 – 1,00) μg/l"}]},{"_id":"6a832b7f884ede9a1b2c5505","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Suma pestycydów fosforoorganicznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma pestycydów fosforoorganicznych (z obliczeń)","reference":"PN-EN 12918:2004","norm_bases":["PN-EN 12918:2004"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Suma pestycydów fosforoorganicznych (z obliczeń) PN-EN 12918:2004 Woda, Woda do spozycia przez ludzi, Scieki Suma pestycydow fosforoorganicznych (z obliczen) PN-EN 12918:2004","categories":["water"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of organophosphorus pesticides (calculated)","search_en":"Water, Water intended for human consumption, Wastewater Sum of organophosphorus pesticides (calculated) PN-EN 12918:2004","test_object_en":"Water, Water intended for human consumption, Wastewater","search_zh":"水、生活饮用水、废水 有机磷农药总量（由计算得出） PN-EN 12918:2004","test_object_zh":"水、生活饮用水、废水","methodology_zh":"有机磷农药总量（由计算得出）"},{"_id":"6a832b7f884ede9a1b2c5506","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie polichlorowanych bifenyli (PCB)","parameters":[{"name":"PCB 28","range":"(0,20 – 1,2) μg/l"},{"name":"PCB 52","range":"(0,20 – 1,2) μg/l"},{"name":"PCB 101","range":"(0,20 – 1,2) μg/l"},{"name":"PCB 118","range":"(0,20 – 1,2) μg/l"},{"name":"PCB 138","range":"(0,20 – 1,2) μg/l"},{"name":"PCB 153","range":"(0,20 – 1,2) μg/l"},{"name":"PCB 180","range":"(0,20 – 1,2) μg/l"},{"name":"Suma polichlorowanych bifenyli (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,20 – 1,2) μg/l\nPCB 52 (0,20 – 1,2) μg/l\nPCB 101 (0,20 – 1,2) μg/l\nPCB 118 (0,20 – 1,2) μg/l\nPCB 138 (0,20 – 1,2) μg/l\nPCB 153 (0,20 – 1,2) μg/l\nPCB 180 (0,20 – 1,2) μg/l\nSuma polichlorowanych bifenyli (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PN-EN ISO 6468:2002","norm_bases":["PN-EN ISO 6468:2002"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,20 – 1,2) μg/l\nPCB 52 (0,20 – 1,2) μg/l\nPCB 101 (0,20 – 1,2) μg/l\nPCB 118 (0,20 – 1,2) μg/l\nPCB 138 (0,20 – 1,2) μg/l\nPCB 153 (0,20 – 1,2) μg/l\nPCB 180 (0,20 – 1,2) μg/l\nSuma polichlorowanych bifenyli (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PN-EN ISO 6468:2002 Woda, Woda do spozycia przez ludzi, Scieki Stezenie polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,20 – 1,2) μg/l\nPCB 52 (0,20 – 1,2) μg/l\nPCB 101 (0,20 – 1,2) μg/l\nPCB 118 (0,20 – 1,2) μg/l\nPCB 138 (0,20 – 1,2) μg/l\nPCB 153 (0,20 – 1,2) μg/l\nPCB 180 (0,20 – 1,2) μg/l\nSuma polichlorowanych bifenyli (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PN-EN ISO 6468:2002","categories":["water"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polychlorinated biphenyls (PCB) concentration","parameters_en":[{"name":"PCB 28","range":"(0,20 – 1,2) μg/l"},{"name":"PCB 52","range":"(0,20 – 1,2) μg/l"},{"name":"PCB 101","range":"(0,20 – 1,2) μg/l"},{"name":"PCB 118","range":"(0,20 – 1,2) μg/l"},{"name":"PCB 138","range":"(0,20 – 1,2) μg/l"},{"name":"PCB 153","range":"(0,20 – 1,2) μg/l"},{"name":"PCB 180","range":"(0,20 – 1,2) μg/l"},{"name":"Sum of polychlorinated biphenyls (calculated)"}],"search_en":"Water, Water intended for human consumption, Wastewater Polychlorinated biphenyls (PCB) concentration Gas chromatography with mass spectrometry detection (GC-MS) PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 Sum of polychlorinated biphenyls (calculated) PN-EN ISO 6468:2002","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Water, Water intended for human consumption, Wastewater","search_zh":"水、生活饮用水、废水 多氯联苯（PCB）浓度 气相色谱-质谱法（GC-MS） PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 多氯联苯总量（由计算得出） PN-EN ISO 6468:2002","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"水、生活饮用水、废水","parameters_zh":[{"name":"PCB 28","range":"(0,20 – 1,2) μg/l"},{"name":"PCB 52","range":"(0,20 – 1,2) μg/l"},{"name":"PCB 101","range":"(0,20 – 1,2) μg/l"},{"name":"PCB 118","range":"(0,20 – 1,2) μg/l"},{"name":"PCB 138","range":"(0,20 – 1,2) μg/l"},{"name":"PCB 153","range":"(0,20 – 1,2) μg/l"},{"name":"PCB 180","range":"(0,20 – 1,2) μg/l"},{"name":"多氯联苯总量（由计算得出）"}],"methodology_zh":"多氯联苯（PCB）浓度"},{"_id":"6a832b7f884ede9a1b2c5507","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie polichlorowanych trifenyli (PCT)","parameters":[{"name":"Zakres","range":"3,3’’-o-PCT (0,20 – 1,20) μg/l"},{"name":"3,3’’-p-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"3,4,4’’-m-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"3,3’’,4,4’’-o-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"3,3’’,4,4’’-p-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"3,3’’,5,5’’-p-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"3,3’,3’’,4,4’’-m-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"2,2’’,4,4’’,5,5’’-p-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"3,3’’,4,4’’,5,5’’-p-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"Suma polichlorowanych trifenyli (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie polichlorowanych trifenyli (PCT)\nZakres:\nZakres 3,3’’-o-PCT (0,20 – 1,20) μg/l\n3,3’’-p-PCT (0,20 – 1,20) μg/l\n3,4,4’’-m-PCT (0,20 – 1,20) μg/l\n3,3’’,4,4’’-o-PCT (0,20 – 1,20) μg/l\n3,3’’,4,4’’-p-PCT (0,20 – 1,20) μg/l\n3,3’’,5,5’’-p-PCT (0,20 – 1,20) μg/l\n3,3’,3’’,4,4’’-m-PCT (0,20 – 1,20) μg/l\n2,2’’,4,4’’,5,5’’-p-PCT (0,20 – 1,20) μg/l\n3,3’’,4,4’’,5,5’’-p-PCT (0,20 – 1,20) μg/l\nSuma polichlorowanych trifenyli (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PN-EN ISO 6468:2002","norm_bases":["PN-EN ISO 6468:2002"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie polichlorowanych trifenyli (PCT)\nZakres:\nZakres 3,3’’-o-PCT (0,20 – 1,20) μg/l\n3,3’’-p-PCT (0,20 – 1,20) μg/l\n3,4,4’’-m-PCT (0,20 – 1,20) μg/l\n3,3’’,4,4’’-o-PCT (0,20 – 1,20) μg/l\n3,3’’,4,4’’-p-PCT (0,20 – 1,20) μg/l\n3,3’’,5,5’’-p-PCT (0,20 – 1,20) μg/l\n3,3’,3’’,4,4’’-m-PCT (0,20 – 1,20) μg/l\n2,2’’,4,4’’,5,5’’-p-PCT (0,20 – 1,20) μg/l\n3,3’’,4,4’’,5,5’’-p-PCT (0,20 – 1,20) μg/l\nSuma polichlorowanych trifenyli (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PN-EN ISO 6468:2002 Woda, Woda do spozycia przez ludzi, Scieki Stezenie polichlorowanych trifenyli (PCT)\nZakres:\nZakres 3,3’’-o-PCT (0,20 – 1,20) μg/l\n3,3’’-p-PCT (0,20 – 1,20) μg/l\n3,4,4’’-m-PCT (0,20 – 1,20) μg/l\n3,3’’,4,4’’-o-PCT (0,20 – 1,20) μg/l\n3,3’’,4,4’’-p-PCT (0,20 – 1,20) μg/l\n3,3’’,5,5’’-p-PCT (0,20 – 1,20) μg/l\n3,3’,3’’,4,4’’-m-PCT (0,20 – 1,20) μg/l\n2,2’’,4,4’’,5,5’’-p-PCT (0,20 – 1,20) μg/l\n3,3’’,4,4’’,5,5’’-p-PCT (0,20 – 1,20) μg/l\nSuma polichlorowanych trifenyli (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PN-EN ISO 6468:2002","categories":["water"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polychlorinated terphenyl (PCT) concentration","parameters_en":[{"name":"Range","range":"3,3’’-o-PCT (0,20 – 1,20) μg/l"},{"name":"3,3’’-p-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"3,4,4’’-m-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"3,3’’,4,4’’-o-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"3,3’’,4,4’’-p-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"3,3’’,5,5’’-p-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"3,3’,3’’,4,4’’-m-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"2,2’’,4,4’’,5,5’’-p-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"3,3’’,4,4’’,5,5’’-p-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"Sum of polychlorinated terphenyls (calculated)"}],"search_en":"Water, Water intended for human consumption, Wastewater Polychlorinated terphenyl (PCT) concentration Gas chromatography with mass spectrometry detection (GC-MS) Range 3,3’’-p-PCT 3,4,4’’-m-PCT 3,3’’,4,4’’-o-PCT 3,3’’,4,4’’-p-PCT 3,3’’,5,5’’-p-PCT 3,3’,3’’,4,4’’-m-PCT 2,2’’,4,4’’,5,5’’-p-PCT 3,3’’,4,4’’,5,5’’-p-PCT Sum of polychlorinated terphenyls (calculated) PN-EN ISO 6468:2002","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"3,3’’-o-PCT (0,20 – 1,20) μg/l"},{"name":"3,3’’-p-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"3,4,4’’-m-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"3,3’’,4,4’’-o-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"3,3’’,4,4’’-p-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"3,3’’,5,5’’-p-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"3,3’,3’’,4,4’’-m-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"2,2’’,4,4’’,5,5’’-p-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"3,3’’,4,4’’,5,5’’-p-PCT","range":"(0,20 – 1,20) μg/l"},{"name":"Suma polichlorowanych trifenyli (z obliczeń)"}],"search_zh":"水、生活饮用水、废水 气相色谱-质谱法（GC-MS） 范围 PN-EN ISO 6468:2002","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c5508","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie kwasów halogenooctowych (HAA)","parameters":[{"name":"Kwas monochlorooctowy (MCAA)"},{"name":"Zakres","range":"(15 – 200) μg/l"},{"name":"Kwas dichlorooctowy (DCAA)","range":"(15 – 200) μg/l"},{"name":"Kwas trichloroctowy (TCAA)","range":"(15 – 200) μg/l"},{"name":"Kwas monobromooctowy (MBAA)","range":"(15 – 200) μg/l"},{"name":"Kwas dibromooctowy (DBAA)","range":"(15 – 200) μg/l"},{"name":"Suma kwasów halogenooctowych (HAA) (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie kwasów halogenooctowych (HAA)\nZakres:\nKwas monochlorooctowy (MCAA)\nZakres (15 – 200) μg/l\nKwas dichlorooctowy (DCAA) (15 – 200) μg/l\nKwas trichloroctowy (TCAA) (15 – 200) μg/l\nKwas monobromooctowy (MBAA) (15 – 200) μg/l\nKwas dibromooctowy (DBAA) (15 – 200) μg/l\nSuma kwasów halogenooctowych (HAA) (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"EFO/PB/38/B:05.09.2025","norm_bases":["EFO/PB/38/B:05.09.2025"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie kwasów halogenooctowych (HAA)\nZakres:\nKwas monochlorooctowy (MCAA)\nZakres (15 – 200) μg/l\nKwas dichlorooctowy (DCAA) (15 – 200) μg/l\nKwas trichloroctowy (TCAA) (15 – 200) μg/l\nKwas monobromooctowy (MBAA) (15 – 200) μg/l\nKwas dibromooctowy (DBAA) (15 – 200) μg/l\nSuma kwasów halogenooctowych (HAA) (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) EFO/PB/38/B:05.09.2025 Woda, Woda do spozycia przez ludzi, Scieki Stezenie kwasow halogenooctowych (HAA)\nZakres:\nKwas monochlorooctowy (MCAA)\nZakres (15 – 200) μg/l\nKwas dichlorooctowy (DCAA) (15 – 200) μg/l\nKwas trichloroctowy (TCAA) (15 – 200) μg/l\nKwas monobromooctowy (MBAA) (15 – 200) μg/l\nKwas dibromooctowy (DBAA) (15 – 200) μg/l\nSuma kwasow halogenooctowych (HAA) (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) EFO/PB/38/B:05.09.2025","categories":["water"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Haloacetic acid (HAA) concentration","parameters_en":[{"name":"Monochloroacetic acid (MCAA)"},{"name":"Range","range":"(15 – 200) μg/l"},{"name":"Dichloroacetic acid (DCAA)","range":"(15 – 200) μg/l"},{"name":"Kwas trichloroctowy (TCAA)","range":"(15 – 200) μg/l"},{"name":"Monobromoacetic acid (MBAA)","range":"(15 – 200) μg/l"},{"name":"Dibromoacetic acid (DBAA)","range":"(15 – 200) μg/l"},{"name":"Sum of haloacetic acids (HAA) (calculated)"}],"search_en":"Water, Water intended for human consumption, Wastewater Haloacetic acid (HAA) concentration Gas chromatography with mass spectrometry detection (GC-MS) Monochloroacetic acid (MCAA) Range Dichloroacetic acid (DCAA) Monobromoacetic acid (MBAA) Dibromoacetic acid (DBAA) Sum of haloacetic acids (HAA) (calculated) EFO/PB/38/B:05.09.2025","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"Kwas monochlorooctowy (MCAA)"},{"name":"范围","range":"(15 – 200) μg/l"},{"name":"Kwas dichlorooctowy (DCAA)","range":"(15 – 200) μg/l"},{"name":"Kwas trichloroctowy (TCAA)","range":"(15 – 200) μg/l"},{"name":"Kwas monobromooctowy (MBAA)","range":"(15 – 200) μg/l"},{"name":"Kwas dibromooctowy (DBAA)","range":"(15 – 200) μg/l"},{"name":"Suma kwasów halogenooctowych (HAA) (z obliczeń)"}],"search_zh":"水、生活饮用水、废水 卤乙酸（HAA）浓度 气相色谱-质谱法（GC-MS） 范围 EFO/PB/38/B:05.09.2025","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"水、生活饮用水、废水","methodology_zh":"卤乙酸（HAA）浓度"},{"_id":"6a832b7f884ede9a1b2c5509","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie Bisfenolu A","parameters":[{"name":"Zakres","range":"(0,05 – 10) μg/l"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie Bisfenolu A\nZakres (0,05 – 10) μg/l\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"EFO/PB/40/B:05.09.2025","norm_bases":["EFO/PB/40/B:05.09.2025"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie Bisfenolu A\nZakres (0,05 – 10) μg/l\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) EFO/PB/40/B:05.09.2025 Woda, Woda do spozycia przez ludzi, Scieki Stezenie Bisfenolu A\nZakres (0,05 – 10) μg/l\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) EFO/PB/40/B:05.09.2025","categories":["water"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bisphenol A concentration","parameters_en":[{"name":"Range","range":"(0,05 – 10) μg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Bisphenol A concentration Gas chromatography with mass spectrometry detection (GC-MS) Range EFO/PB/40/B:05.09.2025","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,05 – 10) μg/l"}],"search_zh":"水、生活饮用水、废水 气相色谱-质谱法（GC-MS） 范围 EFO/PB/40/B:05.09.2025","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c550a","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie ftalanów","parameters":[{"name":"Ftalan dietylu","range":"(1,0 – 100) μg/l"},{"name":"Ftalan di","range":"(2-etyloheksylu) (DEHP)"},{"name":"Zakres","range":"(1,0 – 100) μg/l"},{"name":"Ftalan benzylu butylu","range":"(1,0 – 100) μg/l"},{"name":"Ftalan diizobutylu","range":"(1,0 – 100) μg/l"},{"name":"Ftalan dibutylu","range":"(1,0 – 100) μg/l"},{"name":"Suma ftalanów (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie ftalanów\nZakres:\nFtalan dietylu (1,0 – 100) μg/l\nFtalan di (2-etyloheksylu) (DEHP)\nZakres (1,0 – 100) μg/l\nFtalan benzylu butylu (1,0 – 100) μg/l\nFtalan diizobutylu (1,0 – 100) μg/l\nFtalan dibutylu (1,0 – 100) μg/l\nSuma ftalanów (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PN-EN ISO 18856:2006","norm_bases":["PN-EN ISO 18856:2006"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie ftalanów\nZakres:\nFtalan dietylu (1,0 – 100) μg/l\nFtalan di (2-etyloheksylu) (DEHP)\nZakres (1,0 – 100) μg/l\nFtalan benzylu butylu (1,0 – 100) μg/l\nFtalan diizobutylu (1,0 – 100) μg/l\nFtalan dibutylu (1,0 – 100) μg/l\nSuma ftalanów (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PN-EN ISO 18856:2006 Woda, Woda do spozycia przez ludzi, Scieki Stezenie ftalanow\nZakres:\nFtalan dietylu (1,0 – 100) μg/l\nFtalan di (2-etyloheksylu) (DEHP)\nZakres (1,0 – 100) μg/l\nFtalan benzylu butylu (1,0 – 100) μg/l\nFtalan diizobutylu (1,0 – 100) μg/l\nFtalan dibutylu (1,0 – 100) μg/l\nSuma ftalanow (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PN-EN ISO 18856:2006","categories":["water"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phthalate concentration","parameters_en":[{"name":"Diethyl phthalate","range":"(1,0 – 100) μg/l"},{"name":"Phthalate di","range":"(2-etyloheksylu) (DEHP)"},{"name":"Range","range":"(1,0 – 100) μg/l"},{"name":"Benzyl butyl phthalate","range":"(1,0 – 100) μg/l"},{"name":"Diisobutyl phthalate","range":"(1,0 – 100) μg/l"},{"name":"Dibutyl phthalate","range":"(1,0 – 100) μg/l"},{"name":"Sum of phthalates (calculated)"}],"search_en":"Water, Water intended for human consumption, Wastewater Phthalate concentration Gas chromatography with mass spectrometry detection (GC-MS) Diethyl phthalate Phthalate di Range Benzyl butyl phthalate Diisobutyl phthalate Dibutyl phthalate Sum of phthalates (calculated) PN-EN ISO 18856:2006","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"邻苯二甲酸二乙酯","range":"(1,0 – 100) μg/l"},{"name":"Ftalan di","range":"(2-etyloheksylu) (DEHP)"},{"name":"范围","range":"(1,0 – 100) μg/l"},{"name":"Ftalan benzylu butylu","range":"(1,0 – 100) μg/l"},{"name":"Ftalan diizobutylu","range":"(1,0 – 100) μg/l"},{"name":"Ftalan dibutylu","range":"(1,0 – 100) μg/l"},{"name":"邻苯二甲酸酯总量（由计算得出）"}],"search_zh":"水、生活饮用水、废水 气相色谱-质谱法（GC-MS） 邻苯二甲酸二乙酯 范围 邻苯二甲酸酯总量（由计算得出） PN-EN ISO 18856:2006","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c550b","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"naftalen","range":"(0,0040 – 1,5) μg/l"},{"name":"antracen","range":"(0,0040 – 1,5) μg/l"},{"name":"chryzen","range":"(0,0040 – 1,5) μg/l"},{"name":"benzo(a)antracen","range":"(0,0040 – 1,5) μg/l"},{"name":"dibenzo(a,h)antracen","range":"(0,0040 – 1,5) μg/l"},{"name":"benzo(a)piren","range":"(0,0040 – 1,5) μg/l"},{"name":"benzo(b)fluoranten","range":"(0,0040 – 1,5) μg/l"},{"name":"benzo(k)fluoranten","range":"(0,0040 – 1,5) μg/l"},{"name":"benzo(ghi)perylen","range":"(0,0040 – 1,5) μg/l"},{"name":"indeno(1,2,3-cd)piren","range":"(0,0040 – 1,5) μg/l"},{"name":"acenaften","range":"(0,0040 – 1,5) μg/l"},{"name":"acenaftylen","range":"(0,0040 – 1,5) μg/l"},{"name":"fluoranten","range":"(0,0040 – 1,5) μg/l"},{"name":"fluoren","range":"(0,0040 – 1,5) μg/l"},{"name":"fenantren","range":"(0,0040 – 1,5) μg/l"},{"name":"piren","range":"(0,0040 – 1,5) μg/l"},{"name":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nnaftalen (0,0040 – 1,5) μg/l\nantracen (0,0040 – 1,5) μg/l\nchryzen (0,0040 – 1,5) μg/l\nbenzo(a)antracen (0,0040 – 1,5) μg/l\ndibenzo(a,h)antracen (0,0040 – 1,5) μg/l\nbenzo(a)piren (0,0040 – 1,5) μg/l\nbenzo(b)fluoranten (0,0040 – 1,5) μg/l\nbenzo(k)fluoranten (0,0040 – 1,5) μg/l\nbenzo(ghi)perylen (0,0040 – 1,5) μg/l\nindeno(1,2,3-cd)piren (0,0040 – 1,5) μg/l\nacenaften (0,0040 – 1,5) μg/l\nacenaftylen (0,0040 – 1,5) μg/l\nfluoranten (0,0040 – 1,5) μg/l\nfluoren (0,0040 – 1,5) μg/l\nfenantren (0,0040 – 1,5) μg/l\npiren (0,0040 – 1,5) μg/l\nSuma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"EFO/PB/49/A:30.04.2025","norm_bases":["EFO/PB/49/A:30.04.2025"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nnaftalen (0,0040 – 1,5) μg/l\nantracen (0,0040 – 1,5) μg/l\nchryzen (0,0040 – 1,5) μg/l\nbenzo(a)antracen (0,0040 – 1,5) μg/l\ndibenzo(a,h)antracen (0,0040 – 1,5) μg/l\nbenzo(a)piren (0,0040 – 1,5) μg/l\nbenzo(b)fluoranten (0,0040 – 1,5) μg/l\nbenzo(k)fluoranten (0,0040 – 1,5) μg/l\nbenzo(ghi)perylen (0,0040 – 1,5) μg/l\nindeno(1,2,3-cd)piren (0,0040 – 1,5) μg/l\nacenaften (0,0040 – 1,5) μg/l\nacenaftylen (0,0040 – 1,5) μg/l\nfluoranten (0,0040 – 1,5) μg/l\nfluoren (0,0040 – 1,5) μg/l\nfenantren (0,0040 – 1,5) μg/l\npiren (0,0040 – 1,5) μg/l\nSuma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) EFO/PB/49/A:30.04.2025 Woda, Scieki Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nnaftalen (0,0040 – 1,5) μg/l\nantracen (0,0040 – 1,5) μg/l\nchryzen (0,0040 – 1,5) μg/l\nbenzo(a)antracen (0,0040 – 1,5) μg/l\ndibenzo(a,h)antracen (0,0040 – 1,5) μg/l\nbenzo(a)piren (0,0040 – 1,5) μg/l\nbenzo(b)fluoranten (0,0040 – 1,5) μg/l\nbenzo(k)fluoranten (0,0040 – 1,5) μg/l\nbenzo(ghi)perylen (0,0040 – 1,5) μg/l\nindeno(1,2,3-cd)piren (0,0040 – 1,5) μg/l\nacenaften (0,0040 – 1,5) μg/l\nacenaftylen (0,0040 – 1,5) μg/l\nfluoranten (0,0040 – 1,5) μg/l\nfluoren (0,0040 – 1,5) μg/l\nfenantren (0,0040 – 1,5) μg/l\npiren (0,0040 – 1,5) μg/l\nSuma wielopierscieniowych weglowodorow aromatycznych (WWA) (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) EFO/PB/49/A:30.04.2025","categories":["water"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","parameters_en":[{"name":"naphthalene","range":"(0,0040 – 1,5) μg/l"},{"name":"anthracene","range":"(0,0040 – 1,5) μg/l"},{"name":"chrysene","range":"(0,0040 – 1,5) μg/l"},{"name":"benzo(a)anthracene","range":"(0,0040 – 1,5) μg/l"},{"name":"dibenzo(a,h)anthracene","range":"(0,0040 – 1,5) μg/l"},{"name":"benzo(a)pyrene","range":"(0,0040 – 1,5) μg/l"},{"name":"benzo(b)fluoranthene","range":"(0,0040 – 1,5) μg/l"},{"name":"benzo(k)fluoranthene","range":"(0,0040 – 1,5) μg/l"},{"name":"benzo(ghi)perylene","range":"(0,0040 – 1,5) μg/l"},{"name":"indeno(1,2,3-cd)pyrene","range":"(0,0040 – 1,5) μg/l"},{"name":"acenaphthene","range":"(0,0040 – 1,5) μg/l"},{"name":"acenaphthylene","range":"(0,0040 – 1,5) μg/l"},{"name":"fluoranthene","range":"(0,0040 – 1,5) μg/l"},{"name":"fluorene","range":"(0,0040 – 1,5) μg/l"},{"name":"phenanthrene","range":"(0,0040 – 1,5) μg/l"},{"name":"pyrene","range":"(0,0040 – 1,5) μg/l"},{"name":"Sum of polycyclic aromatic hydrocarbons (PAH) (calculated)"}],"search_en":"Water, Wastewater Concentration of polycyclic aromatic hydrocarbons (PAH) Gas chromatography with mass spectrometry detection (GC-MS) naphthalene anthracene chrysene benzo(a)anthracene dibenzo(a,h)anthracene benzo(a)pyrene benzo(b)fluoranthene benzo(k)fluoranthene benzo(ghi)perylene indeno(1,2,3-cd)pyrene acenaphthene acenaphthylene fluoranthene fluorene phenanthrene pyrene Sum of polycyclic aromatic hydrocarbons (PAH) (calculated) EFO/PB/49/A:30.04.2025","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Water, Wastewater","search_zh":"水、污水 多环芳烃（PAHs）浓度 气相色谱-质谱法（GC-MS） 萘 蒽 䓛 苯并（a）蒽 二苯并（a,h）蒽 苯并（a）芘 苯并（b）荧蒽 苯并（k）荧蒽 苯并（ghi）苝 茚并(1,2,3-cd)芘 苊 苊烯 荧蒽 芴 菲 芘 多环芳烃（PAH）总量（由计算得出） EFO/PB/49/A:30.04.2025","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"水、污水","parameters_zh":[{"name":"萘","range":"(0,0040 – 1,5) μg/l"},{"name":"蒽","range":"(0,0040 – 1,5) μg/l"},{"name":"䓛","range":"(0,0040 – 1,5) μg/l"},{"name":"苯并（a）蒽","range":"(0,0040 – 1,5) μg/l"},{"name":"二苯并（a,h）蒽","range":"(0,0040 – 1,5) μg/l"},{"name":"苯并（a）芘","range":"(0,0040 – 1,5) μg/l"},{"name":"苯并（b）荧蒽","range":"(0,0040 – 1,5) μg/l"},{"name":"苯并（k）荧蒽","range":"(0,0040 – 1,5) μg/l"},{"name":"苯并（ghi）苝","range":"(0,0040 – 1,5) μg/l"},{"name":"茚并(1,2,3-cd)芘","range":"(0,0040 – 1,5) μg/l"},{"name":"苊","range":"(0,0040 – 1,5) μg/l"},{"name":"苊烯","range":"(0,0040 – 1,5) μg/l"},{"name":"荧蒽","range":"(0,0040 – 1,5) μg/l"},{"name":"芴","range":"(0,0040 – 1,5) μg/l"},{"name":"菲","range":"(0,0040 – 1,5) μg/l"},{"name":"芘","range":"(0,0040 – 1,5) μg/l"},{"name":"多环芳烃（PAH）总量（由计算得出）"}],"methodology_zh":"多环芳烃（PAHs）浓度"},{"_id":"6a832b7f884ede9a1b2c550c","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"naftalen","range":"(0,0040 – 1,5) μg/l"},{"name":"antracen","range":"(0,0040 – 1,5) μg/l"},{"name":"chryzen","range":"(0,0040 – 1,5) μg/l"},{"name":"benzo(a)antracen","range":"(0,0040 – 1,5) μg/l"},{"name":"dibenzo(a,h)antracen","range":"(0,0040 – 1,5) μg/l"},{"name":"benzo(a)piren","range":"(0,0030 – 1,5) μg/l"},{"name":"benzo(b)fluoranten","range":"(0,0040 – 1,5) μg/l"},{"name":"benzo(k)fluoranten","range":"(0,0040 – 1,5) μg/l"},{"name":"benzo(ghi)perylen","range":"(0,0040 – 1,5) μg/l"},{"name":"indeno(1,2,3-cd)piren","range":"(0,0040 – 1,5) μg/l"},{"name":"acenaften","range":"(0,0040 – 1,5) μg/l"},{"name":"acenaftylen","range":"(0,0040 – 1,5) μg/l"},{"name":"fluoranten","range":"(0,0040 – 1,5) μg/l"},{"name":"fluoren","range":"(0,0040 – 1,5) μg/l"},{"name":"fenantren","range":"(0,0040 – 1,5) μg/l"},{"name":"piren","range":"(0,0040 – 1,5) μg/l"},{"name":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nnaftalen (0,0040 – 1,5) μg/l\nantracen (0,0040 – 1,5) μg/l\nchryzen (0,0040 – 1,5) μg/l\nbenzo(a)antracen (0,0040 – 1,5) μg/l\ndibenzo(a,h)antracen (0,0040 – 1,5) μg/l\nbenzo(a)piren (0,0030 – 1,5) μg/l\nbenzo(b)fluoranten (0,0040 – 1,5) μg/l\nbenzo(k)fluoranten (0,0040 – 1,5) μg/l\nbenzo(ghi)perylen (0,0040 – 1,5) μg/l\nindeno(1,2,3-cd)piren (0,0040 – 1,5) μg/l\nacenaften (0,0040 – 1,5) μg/l\nacenaftylen (0,0040 – 1,5) μg/l\nfluoranten (0,0040 – 1,5) μg/l\nfluoren (0,0040 – 1,5) μg/l\nfenantren (0,0040 – 1,5) μg/l\npiren (0,0040 – 1,5) μg/l\nSuma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"EFO/PB/49/A:30.04.2025","norm_bases":["EFO/PB/49/A:30.04.2025"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nnaftalen (0,0040 – 1,5) μg/l\nantracen (0,0040 – 1,5) μg/l\nchryzen (0,0040 – 1,5) μg/l\nbenzo(a)antracen (0,0040 – 1,5) μg/l\ndibenzo(a,h)antracen (0,0040 – 1,5) μg/l\nbenzo(a)piren (0,0030 – 1,5) μg/l\nbenzo(b)fluoranten (0,0040 – 1,5) μg/l\nbenzo(k)fluoranten (0,0040 – 1,5) μg/l\nbenzo(ghi)perylen (0,0040 – 1,5) μg/l\nindeno(1,2,3-cd)piren (0,0040 – 1,5) μg/l\nacenaften (0,0040 – 1,5) μg/l\nacenaftylen (0,0040 – 1,5) μg/l\nfluoranten (0,0040 – 1,5) μg/l\nfluoren (0,0040 – 1,5) μg/l\nfenantren (0,0040 – 1,5) μg/l\npiren (0,0040 – 1,5) μg/l\nSuma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) EFO/PB/49/A:30.04.2025 Woda do spozycia przez ludzi Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nnaftalen (0,0040 – 1,5) μg/l\nantracen (0,0040 – 1,5) μg/l\nchryzen (0,0040 – 1,5) μg/l\nbenzo(a)antracen (0,0040 – 1,5) μg/l\ndibenzo(a,h)antracen (0,0040 – 1,5) μg/l\nbenzo(a)piren (0,0030 – 1,5) μg/l\nbenzo(b)fluoranten (0,0040 – 1,5) μg/l\nbenzo(k)fluoranten (0,0040 – 1,5) μg/l\nbenzo(ghi)perylen (0,0040 – 1,5) μg/l\nindeno(1,2,3-cd)piren (0,0040 – 1,5) μg/l\nacenaften (0,0040 – 1,5) μg/l\nacenaftylen (0,0040 – 1,5) μg/l\nfluoranten (0,0040 – 1,5) μg/l\nfluoren (0,0040 – 1,5) μg/l\nfenantren (0,0040 – 1,5) μg/l\npiren (0,0040 – 1,5) μg/l\nSuma wielopierscieniowych weglowodorow aromatycznych (WWA) (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) EFO/PB/49/A:30.04.2025","categories":["water"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","parameters_en":[{"name":"naphthalene","range":"(0,0040 – 1,5) μg/l"},{"name":"anthracene","range":"(0,0040 – 1,5) μg/l"},{"name":"chrysene","range":"(0,0040 – 1,5) μg/l"},{"name":"benzo(a)anthracene","range":"(0,0040 – 1,5) μg/l"},{"name":"dibenzo(a,h)anthracene","range":"(0,0040 – 1,5) μg/l"},{"name":"benzo(a)pyrene","range":"(0,0030 – 1,5) μg/l"},{"name":"benzo(b)fluoranthene","range":"(0,0040 – 1,5) μg/l"},{"name":"benzo(k)fluoranthene","range":"(0,0040 – 1,5) μg/l"},{"name":"benzo(ghi)perylene","range":"(0,0040 – 1,5) μg/l"},{"name":"indeno(1,2,3-cd)pyrene","range":"(0,0040 – 1,5) μg/l"},{"name":"acenaphthene","range":"(0,0040 – 1,5) μg/l"},{"name":"acenaphthylene","range":"(0,0040 – 1,5) μg/l"},{"name":"fluoranthene","range":"(0,0040 – 1,5) μg/l"},{"name":"fluorene","range":"(0,0040 – 1,5) μg/l"},{"name":"phenanthrene","range":"(0,0040 – 1,5) μg/l"},{"name":"pyrene","range":"(0,0040 – 1,5) μg/l"},{"name":"Sum of polycyclic aromatic hydrocarbons (PAH) (calculated)"}],"search_en":"Water intended for human consumption Concentration of polycyclic aromatic hydrocarbons (PAH) Gas chromatography with mass spectrometry detection (GC-MS) naphthalene anthracene chrysene benzo(a)anthracene dibenzo(a,h)anthracene benzo(a)pyrene benzo(b)fluoranthene benzo(k)fluoranthene benzo(ghi)perylene indeno(1,2,3-cd)pyrene acenaphthene acenaphthylene fluoranthene fluorene phenanthrene pyrene Sum of polycyclic aromatic hydrocarbons (PAH) (calculated) EFO/PB/49/A:30.04.2025","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 多环芳烃（PAHs）浓度 气相色谱-质谱法（GC-MS） 萘 蒽 䓛 苯并（a）蒽 二苯并（a,h）蒽 苯并（a）芘 苯并（b）荧蒽 苯并（k）荧蒽 苯并（ghi）苝 茚并(1,2,3-cd)芘 苊 苊烯 荧蒽 芴 菲 芘 多环芳烃（PAH）总量（由计算得出） EFO/PB/49/A:30.04.2025","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"生活饮用水","parameters_zh":[{"name":"萘","range":"(0,0040 – 1,5) μg/l"},{"name":"蒽","range":"(0,0040 – 1,5) μg/l"},{"name":"䓛","range":"(0,0040 – 1,5) μg/l"},{"name":"苯并（a）蒽","range":"(0,0040 – 1,5) μg/l"},{"name":"二苯并（a,h）蒽","range":"(0,0040 – 1,5) μg/l"},{"name":"苯并（a）芘","range":"(0,0030 – 1,5) μg/l"},{"name":"苯并（b）荧蒽","range":"(0,0040 – 1,5) μg/l"},{"name":"苯并（k）荧蒽","range":"(0,0040 – 1,5) μg/l"},{"name":"苯并（ghi）苝","range":"(0,0040 – 1,5) μg/l"},{"name":"茚并(1,2,3-cd)芘","range":"(0,0040 – 1,5) μg/l"},{"name":"苊","range":"(0,0040 – 1,5) μg/l"},{"name":"苊烯","range":"(0,0040 – 1,5) μg/l"},{"name":"荧蒽","range":"(0,0040 – 1,5) μg/l"},{"name":"芴","range":"(0,0040 – 1,5) μg/l"},{"name":"菲","range":"(0,0040 – 1,5) μg/l"},{"name":"芘","range":"(0,0040 – 1,5) μg/l"},{"name":"多环芳烃（PAH）总量（由计算得出）"}],"methodology_zh":"多环芳烃（PAHs）浓度"},{"_id":"6a832b7f884ede9a1b2c550d","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie chlorofenoli","parameters":[{"name":"Zakres","range":"2-chlorofenol (0,0010 – 1,0) μg/l"},{"name":"3-chlorofenol","range":"(0,0010 – 1,0) μg/l"},{"name":"4-chlorofenol","range":"(0,0010 – 1,0) μg/l"},{"name":"2,3-dichlorofenol","range":"(0,0010 – 1,0) μg/l"},{"name":"2,4+2,5-dichlorofenol","range":"(0,0010 – 2,0) μg/l"},{"name":"2,6-dichlorofenol","range":"(0,0010 – 1,0) μg/l"},{"name":"3,4-dichlorofenol","range":"(0,0010 – 1,0) μg/l"},{"name":"3,5-dichlorofenol","range":"(0,0010 – 1,0) μg/l"},{"name":"2,3,4-trichlorofenol","range":"(0,0010 – 1,0) μg/l"},{"name":"2,3,5-trichlorofenol","range":"(0,0010 – 1,0) μg/l"},{"name":"2,3,6-trichlorofenol","range":"(0,0010 – 1,0) μg/l"},{"name":"2,4,5-trichlorofenol","range":"(0,0010 – 1,0) μg/l"},{"name":"2,4,6-trichlorofenol","range":"(0,0010 – 1,0) μg/l"},{"name":"3,4,5-trichlorofenol","range":"(0,0010 – 1,0) μg/l"},{"name":"2,3,4,5-tetrachlorofenol","range":"(0,0010 – 1,0) μg/l"},{"name":"2,3,4,6-tetrachlorofenol","range":"(0,0010 – 1,0) μg/l"},{"name":"2,3,5,6-tetrachlorofenol","range":"(0,0010 – 1,0) μg/l"},{"name":"pentachlorofenol (PCP)","range":"(0,0010 – 1,0) μg/l"},{"name":"Suma: chlorofenoli monochlorofenoli dichlorofenoli trichlorofenoli tetrachlorofenoli (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Stężenie chlorofenoli\nZakres:\nZakres 2-chlorofenol (0,0010 – 1,0) μg/l\n3-chlorofenol (0,0010 – 1,0) μg/l\n4-chlorofenol (0,0010 – 1,0) μg/l\n2,3-dichlorofenol (0,0010 – 1,0) μg/l\n2,4+2,5-dichlorofenol (0,0010 – 2,0) μg/l\n2,6-dichlorofenol (0,0010 – 1,0) μg/l\n3,4-dichlorofenol (0,0010 – 1,0) μg/l\n3,5-dichlorofenol (0,0010 – 1,0) μg/l\n2,3,4-trichlorofenol (0,0010 – 1,0) μg/l\n2,3,5-trichlorofenol (0,0010 – 1,0) μg/l\n2,3,6-trichlorofenol (0,0010 – 1,0) μg/l\n2,4,5-trichlorofenol (0,0010 – 1,0) μg/l\n2,4,6-trichlorofenol (0,0010 – 1,0) μg/l\n3,4,5-trichlorofenol (0,0010 – 1,0) μg/l\n2,3,4,5-tetrachlorofenol (0,0010 – 1,0) μg/l\n2,3,4,6-tetrachlorofenol (0,0010 – 1,0) μg/l\n2,3,5,6-tetrachlorofenol (0,0010 – 1,0) μg/l\npentachlorofenol (PCP) (0,0010 – 1,0) μg/l\nSuma: chlorofenoli monochlorofenoli dichlorofenoli trichlorofenoli tetrachlorofenoli (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS-MS)","reference":"PN-EN 12673:2004","norm_bases":["PN-EN 12673:2004"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie chlorofenoli\nZakres:\nZakres 2-chlorofenol (0,0010 – 1,0) μg/l\n3-chlorofenol (0,0010 – 1,0) μg/l\n4-chlorofenol (0,0010 – 1,0) μg/l\n2,3-dichlorofenol (0,0010 – 1,0) μg/l\n2,4+2,5-dichlorofenol (0,0010 – 2,0) μg/l\n2,6-dichlorofenol (0,0010 – 1,0) μg/l\n3,4-dichlorofenol (0,0010 – 1,0) μg/l\n3,5-dichlorofenol (0,0010 – 1,0) μg/l\n2,3,4-trichlorofenol (0,0010 – 1,0) μg/l\n2,3,5-trichlorofenol (0,0010 – 1,0) μg/l\n2,3,6-trichlorofenol (0,0010 – 1,0) μg/l\n2,4,5-trichlorofenol (0,0010 – 1,0) μg/l\n2,4,6-trichlorofenol (0,0010 – 1,0) μg/l\n3,4,5-trichlorofenol (0,0010 – 1,0) μg/l\n2,3,4,5-tetrachlorofenol (0,0010 – 1,0) μg/l\n2,3,4,6-tetrachlorofenol (0,0010 – 1,0) μg/l\n2,3,5,6-tetrachlorofenol (0,0010 – 1,0) μg/l\npentachlorofenol (PCP) (0,0010 – 1,0) μg/l\nSuma: chlorofenoli monochlorofenoli dichlorofenoli trichlorofenoli tetrachlorofenoli (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS-MS) PN-EN 12673:2004 Woda, Woda do spozycia przez ludzi, Scieki Stezenie chlorofenoli\nZakres:\nZakres 2-chlorofenol (0,0010 – 1,0) μg/l\n3-chlorofenol (0,0010 – 1,0) μg/l\n4-chlorofenol (0,0010 – 1,0) μg/l\n2,3-dichlorofenol (0,0010 – 1,0) μg/l\n2,4+2,5-dichlorofenol (0,0010 – 2,0) μg/l\n2,6-dichlorofenol (0,0010 – 1,0) μg/l\n3,4-dichlorofenol (0,0010 – 1,0) μg/l\n3,5-dichlorofenol (0,0010 – 1,0) μg/l\n2,3,4-trichlorofenol (0,0010 – 1,0) μg/l\n2,3,5-trichlorofenol (0,0010 – 1,0) μg/l\n2,3,6-trichlorofenol (0,0010 – 1,0) μg/l\n2,4,5-trichlorofenol (0,0010 – 1,0) μg/l\n2,4,6-trichlorofenol (0,0010 – 1,0) μg/l\n3,4,5-trichlorofenol (0,0010 – 1,0) μg/l\n2,3,4,5-tetrachlorofenol (0,0010 – 1,0) μg/l\n2,3,4,6-tetrachlorofenol (0,0010 – 1,0) μg/l\n2,3,5,6-tetrachlorofenol (0,0010 – 1,0) μg/l\npentachlorofenol (PCP) (0,0010 – 1,0) μg/l\nSuma: chlorofenoli monochlorofenoli dichlorofenoli trichlorofenoli tetrachlorofenoli (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS-MS) PN-EN 12673:2004","categories":["water"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorophenol concentration","parameters_en":[{"name":"Range","range":"2-chlorofenol (0,0010 – 1,0) μg/l"},{"name":"3-chlorophenol","range":"(0,0010 – 1,0) μg/l"},{"name":"4-chlorophenol","range":"(0,0010 – 1,0) μg/l"},{"name":"2,3-dichlorophenol","range":"(0,0010 – 1,0) μg/l"},{"name":"2,4+2,5-dichlorophenol","range":"(0,0010 – 2,0) μg/l"},{"name":"2,6-dichlorophenol","range":"(0,0010 – 1,0) μg/l"},{"name":"3,4-dichlorophenol","range":"(0,0010 – 1,0) μg/l"},{"name":"3,5-dichlorophenol","range":"(0,0010 – 1,0) μg/l"},{"name":"2,3,4-trichlorophenol","range":"(0,0010 – 1,0) μg/l"},{"name":"2,3,5-trichlorophenol","range":"(0,0010 – 1,0) μg/l"},{"name":"2,3,6-trichlorophenol","range":"(0,0010 – 1,0) μg/l"},{"name":"2,4,5-trichlorophenol","range":"(0,0010 – 1,0) μg/l"},{"name":"2,4,6-trichlorophenol","range":"(0,0010 – 1,0) μg/l"},{"name":"3,4,5-trichlorophenol","range":"(0,0010 – 1,0) μg/l"},{"name":"2,3,4,5-tetrachlorophenol","range":"(0,0010 – 1,0) μg/l"},{"name":"2,3,4,6-tetrachlorophenol","range":"(0,0010 – 1,0) μg/l"},{"name":"2,3,5,6-tetrachlorophenol","range":"(0,0010 – 1,0) μg/l"},{"name":"pentachlorophenol (PCP)","range":"(0,0010 – 1,0) μg/l"},{"name":"Suma: chlorofenoli monochlorofenoli dichlorofenoli trichlorofenoli tetrachlorofenoli (z obliczeń)"}],"search_en":"Water, Water intended for human consumption, Wastewater Chlorophenol concentration Gas chromatography with mass spectrometry detection (GC-MS-MS) Range 3-chlorophenol 4-chlorophenol 2,3-dichlorophenol 2,4+2,5-dichlorophenol 2,6-dichlorophenol 3,4-dichlorophenol 3,5-dichlorophenol 2,3,4-trichlorophenol 2,3,5-trichlorophenol 2,3,6-trichlorophenol 2,4,5-trichlorophenol 2,4,6-trichlorophenol 3,4,5-trichlorophenol 2,3,4,5-tetrachlorophenol 2,3,4,6-tetrachlorophenol 2,3,5,6-tetrachlorophenol pentachlorophenol (PCP) PN-EN 12673:2004","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS-MS)","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"2-chlorofenol (0,0010 – 1,0) μg/l"},{"name":"3-氯苯酚","range":"(0,0010 – 1,0) μg/l"},{"name":"4-氯苯酚","range":"(0,0010 – 1,0) μg/l"},{"name":"2,3-二氯苯酚","range":"(0,0010 – 1,0) μg/l"},{"name":"2,4+2,5-dichlorofenol","range":"(0,0010 – 2,0) μg/l"},{"name":"2,6-二氯苯酚","range":"(0,0010 – 1,0) μg/l"},{"name":"3,4-二氯苯酚","range":"(0,0010 – 1,0) μg/l"},{"name":"3,5-二氯苯酚","range":"(0,0010 – 1,0) μg/l"},{"name":"2,3,4-三氯苯酚","range":"(0,0010 – 1,0) μg/l"},{"name":"2,3,5-三氯苯酚","range":"(0,0010 – 1,0) μg/l"},{"name":"2,3,6-三氯苯酚","range":"(0,0010 – 1,0) μg/l"},{"name":"2,4,5-三氯苯酚","range":"(0,0010 – 1,0) μg/l"},{"name":"2,4,6-三氯苯酚","range":"(0,0010 – 1,0) μg/l"},{"name":"3,4,5-三氯苯酚","range":"(0,0010 – 1,0) μg/l"},{"name":"2,3,4,5-四氯苯酚","range":"(0,0010 – 1,0) μg/l"},{"name":"2,3,4,6-四氯苯酚","range":"(0,0010 – 1,0) μg/l"},{"name":"2,3,5,6-tetrachlorofenol","range":"(0,0010 – 1,0) μg/l"},{"name":"五氯苯酚（PCP）","range":"(0,0010 – 1,0) μg/l"},{"name":"Suma: chlorofenoli monochlorofenoli dichlorofenoli trichlorofenoli tetrachlorofenoli (z obliczeń)"}],"search_zh":"水、生活饮用水、废水 范围 3-氯苯酚 4-氯苯酚 2,3-二氯苯酚 2,6-二氯苯酚 3,4-二氯苯酚 3,5-二氯苯酚 2,3,4-三氯苯酚 2,3,5-三氯苯酚 2,3,6-三氯苯酚 2,4,5-三氯苯酚 2,4,6-三氯苯酚 3,4,5-三氯苯酚 2,3,4,5-四氯苯酚 2,3,4,6-四氯苯酚 五氯苯酚（PCP） PN-EN 12673:2004","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c550e","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie rodanków","parameters":[{"name":"Zakres","range":"(0,5 – 400) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie rodanków\nZakres (0,5 – 400) mg/l\nMetoda spektrofotometryczna","reference":"EFO/PB/42/A:30.04.2025","norm_bases":["EFO/PB/42/A:30.04.2025"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie rodanków\nZakres (0,5 – 400) mg/l\nMetoda spektrofotometryczna EFO/PB/42/A:30.04.2025 Woda, Woda do spozycia przez ludzi, Scieki Stezenie rodankow\nZakres (0,5 – 400) mg/l\nMetoda spektrofotometryczna EFO/PB/42/A:30.04.2025","categories":["water"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Thiocyanate concentration","parameters_en":[{"name":"Range","range":"(0,5 – 400) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Thiocyanate concentration Spectrophotometric method Range EFO/PB/42/A:30.04.2025","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,5 – 400) mg/l"}],"search_zh":"水、生活饮用水、废水 硫氰酸盐浓度 分光光度法 范围 EFO/PB/42/A:30.04.2025","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"硫氰酸盐浓度"},{"_id":"6a832b7f884ede9a1b2c550f","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,0005 – 0,50) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,0005 – 0,50) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012 +Ap1:2016-07","norm_bases":["PN-EN ISO 12846:2012 +Ap1:2016-07"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie rtęci\nZakres (0,0005 – 0,50) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 +Ap1:2016-07 Woda, Woda do spozycia przez ludzi, Scieki Stezenie rteci\nZakres (0,0005 – 0,50) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 +Ap1:2016-07","categories":["water"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,0005 – 0,50) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN ISO 12846:2012 +Ap1:2016-07","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,0005 – 0,50) mg/l"}],"search_zh":"水、生活饮用水、废水 汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN ISO 12846:2012 +Ap1:2016-07","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c5510","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(0,5 – 35000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (0,5 – 35000) mg/l\nMetoda spektrofotometryczna","reference":"PB/FCH/102/A:01.07.2020","norm_bases":["PB/FCH/102/A:01.07.2020"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie siarczanów\nZakres (0,5 – 35000) mg/l\nMetoda spektrofotometryczna PB/FCH/102/A:01.07.2020 Woda, Woda do spozycia przez ludzi, Scieki Stezenie siarczanow\nZakres (0,5 – 35000) mg/l\nMetoda spektrofotometryczna PB/FCH/102/A:01.07.2020","categories":["water"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(0,5 – 35000) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Sulfate concentration Spectrophotometric method Range PB/FCH/102/A:01.07.2020","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,5 – 35000) mg/l"}],"search_zh":"水、生活饮用水、废水 硫酸盐浓度 分光光度法 范围 PB/FCH/102/A:01.07.2020","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c5511","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie siarczków","parameters":[{"name":"Zakres","range":"(0,10 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczków\nZakres (0,10 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PB/FCH/75/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 653","norm_bases":["PB/FCH/75/A:10.04.2012","na podstawie testu kuwetowego HACH Lange nr LCK 653"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie siarczków\nZakres (0,10 – 20,0) mg/l\nMetoda spektrofotometryczna PB/FCH/75/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 653 Woda, Woda do spozycia przez ludzi, Scieki Stezenie siarczkow\nZakres (0,10 – 20,0) mg/l\nMetoda spektrofotometryczna PB/FCH/75/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 653","categories":["water"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfide concentration","parameters_en":[{"name":"Range","range":"(0,10 – 20,0) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Sulfide concentration Spectrophotometric method Range PB/FCH/75/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 653","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 20,0) mg/l"}],"search_zh":"水、生活饮用水、废水 硫化物浓度 分光光度法 范围 PB/FCH/75/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 653","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"硫化物浓度"},{"_id":"6a832b7f884ede9a1b2c5512","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie siarczynów","parameters":[{"name":"Zakres","range":"(0,10 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczynów\nZakres (0,10 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PB/FCH/76/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 564","norm_bases":["PB/FCH/76/A:10.04.2012","na podstawie testu kuwetowego HACH Lange nr LCK 564"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie siarczynów\nZakres (0,10 – 50,0) mg/l\nMetoda spektrofotometryczna PB/FCH/76/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 564 Woda, Woda do spozycia przez ludzi, Scieki Stezenie siarczynow\nZakres (0,10 – 50,0) mg/l\nMetoda spektrofotometryczna PB/FCH/76/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 564","categories":["water"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfite concentration","parameters_en":[{"name":"Range","range":"(0,10 – 50,0) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Sulfite concentration Spectrophotometric method Range PB/FCH/76/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 564","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 50,0) mg/l"}],"search_zh":"水、生活饮用水、废水 亚硫酸盐浓度 分光光度法 范围 PB/FCH/76/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 564","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"亚硫酸盐浓度"},{"_id":"6a832b7f884ede9a1b2c5513","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie siarkowodoru i siarczków","parameters":[{"name":"Zakres","range":"(0,2 – 10,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie siarkowodoru i siarczków\nZakres (0,2 – 10,0) mg/l\nMetoda miareczkowa","reference":"PN-74/C-04566/03","norm_bases":["PN-74/C-04566/03"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie siarkowodoru i siarczków\nZakres (0,2 – 10,0) mg/l\nMetoda miareczkowa PN-74/C-04566/03 Woda, Woda do spozycia przez ludzi, Scieki Stezenie siarkowodoru i siarczkow\nZakres (0,2 – 10,0) mg/l\nMetoda miareczkowa PN-74/C-04566/03","categories":["water"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen sulfide and sulfide concentration","parameters_en":[{"name":"Range","range":"(0,2 – 10,0) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Hydrogen sulfide and sulfide concentration Titrimetric method Range PN-74/C-04566/03","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,2 – 10,0) mg/l"}],"search_zh":"水、生活饮用水、废水 硫化氢与硫化物浓度 滴定法 范围 PN-74/C-04566/03","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"硫化氢与硫化物浓度"},{"_id":"6a832b7f884ede9a1b2c5514","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5 – 20,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 – 20,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie tlenu rozpuszczonego\nZakres (0,5 – 20,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda, Woda do spozycia przez ludzi, Scieki Stezenie tlenu rozpuszczonego\nZakres (0,5 – 20,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 20,0) mg/l O2"}],"search_en":"Water, Water intended for human consumption, Wastewater Dissolved oxygen concentration Electrochemical method Range PN-EN ISO 5814:2013-04","technique_en":"Electrochemical method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,5 – 20,0) mg/l O2"}],"search_zh":"水、生活饮用水、废水 溶解氧浓度 电化学法 范围 PN-EN ISO 5814:2013-04","technique_zh":"电化学法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"溶解氧浓度"},{"_id":"6a832b7f884ede9a1b2c5515","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,2 – 20,0) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,2 – 20,0) mg/l O2\nMetoda miareczkowa","reference":"PN-EN 25813:1997","norm_bases":["PN-EN 25813:1997"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie tlenu rozpuszczonego\nZakres (0,2 – 20,0) mg/l O2\nMetoda miareczkowa PN-EN 25813:1997 Woda, Woda do spozycia przez ludzi, Scieki Stezenie tlenu rozpuszczonego\nZakres (0,2 – 20,0) mg/l O2\nMetoda miareczkowa PN-EN 25813:1997","categories":["water"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,2 – 20,0) mg/l O2"}],"search_en":"Water, Water intended for human consumption, Wastewater Dissolved oxygen concentration Titrimetric method Range PN-EN 25813:1997","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,2 – 20,0) mg/l O2"}],"search_zh":"水、生活饮用水、废水 溶解氧浓度 滴定法 范围 PN-EN 25813:1997","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"溶解氧浓度"},{"_id":"6a832b7f884ede9a1b2c5516","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie węglowodorów (C6-C12) / benzyny","parameters":[{"name":"Zakres","range":"(0,050 – 250) mg/l"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Stężenie węglowodorów (C6-C12) / benzyny\nZakres (0,050 – 250) mg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PB/I/3/G:10.04.2017","norm_bases":["PB/I/3/G:10.04.2017"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie węglowodorów (C6-C12) / benzyny\nZakres (0,050 – 250) mg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID) PB/I/3/G:10.04.2017 Woda, Woda do spozycia przez ludzi, Scieki Stezenie weglowodorow (C6-C12) / benzyny\nZakres (0,050 – 250) mg/l\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej z detekcja plomieniowo-jonizacyjna (HS-GC-FID) PB/I/3/G:10.04.2017","categories":["water"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrocarbon concentration (C6-C12) / gasoline","parameters_en":[{"name":"Range","range":"(0,050 – 250) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Hydrocarbon concentration (C6-C12) / gasoline Headspace gas chromatography with flame ionization detection (HS-GC-FID) Range PB/I/3/G:10.04.2017","technique_en":"Headspace gas chromatography with flame ionization detection (HS-GC-FID)","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,050 – 250) mg/l"}],"search_zh":"水、生活饮用水、废水 顶空气相色谱-火焰离子化检测法（HS-GC-FID） 范围 PB/I/3/G:10.04.2017","test_object_zh":"水、生活饮用水、废水","technique_zh":"顶空气相色谱-火焰离子化检测法（HS-GC-FID）"},{"_id":"6a832b7f884ede9a1b2c5517","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,010 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,010 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001","norm_bases":["PN-ISO 6332:2001"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie żelaza ogólnego\nZakres (0,010 – 50,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 Woda, Woda do spozycia przez ludzi, Scieki Stezenie zelaza ogolnego\nZakres (0,010 – 50,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001","categories":["water"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,010 – 50,0) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 50,0) mg/l"}],"search_zh":"水、生活饮用水、废水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c5518","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie żelaza (II)","parameters":[{"name":"Zakres","range":"(0,010 – 50,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza (II)\nZakres (0,010 – 50,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001","norm_bases":["PN-ISO 6332:2001"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie żelaza (II)\nZakres (0,010 – 50,00) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 Woda, Woda do spozycia przez ludzi, Scieki Stezenie zelaza (II)\nZakres (0,010 – 50,00) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001","categories":["water"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron (II) concentration","parameters_en":[{"name":"Range","range":"(0,010 – 50,00) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Iron (II) concentration Spectrophotometric method Range PN-ISO 6332:2001","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 50,00) mg/l"}],"search_zh":"水、生活饮用水、废水 分光光度法 范围 PN-ISO 6332:2001","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c5519","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie żelaza (III) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie żelaza (III) (z obliczeń)","reference":"PN-ISO 6332:2001","norm_bases":["PN-ISO 6332:2001"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie żelaza (III) (z obliczeń) PN-ISO 6332:2001 Woda, Woda do spozycia przez ludzi, Scieki Stezenie zelaza (III) (z obliczen) PN-ISO 6332:2001","categories":["water"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron (III) concentration (calculated)","search_en":"Water, Water intended for human consumption, Wastewater Iron (III) concentration (calculated) PN-ISO 6332:2001","test_object_en":"Water, Water intended for human consumption, Wastewater","search_zh":"水、生活饮用水、废水 PN-ISO 6332:2001","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c551a","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Substancje ekstrahujące się chloroformem","parameters":[{"name":"Zakres","range":"(3,0 – 100) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje ekstrahujące się chloroformem\nZakres (3,0 – 100) mg/l\nMetoda wagowa","reference":"PB/FCH/2/C:18.06.2018","norm_bases":["PB/FCH/2/C:18.06.2018"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Substancje ekstrahujące się chloroformem\nZakres (3,0 – 100) mg/l\nMetoda wagowa PB/FCH/2/C:18.06.2018 Woda, Woda do spozycia przez ludzi, Scieki Substancje ekstrahujace sie chloroformem\nZakres (3,0 – 100) mg/l\nMetoda wagowa PB/FCH/2/C:18.06.2018","categories":["water"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloroform extractable substances","parameters_en":[{"name":"Range","range":"(3,0 – 100) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Chloroform extractable substances Gravimetric method Range PB/FCH/2/C:18.06.2018","technique_en":"Gravimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(3,0 – 100) mg/l"}],"search_zh":"水、生活饮用水、废水 重量法 范围 PB/FCH/2/C:18.06.2018","technique_zh":"重量法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c551b","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Substancje ekstrahujące się eterem naftowym","parameters":[{"name":"Zakres","range":"(3,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje ekstrahujące się eterem naftowym\nZakres (3,0 – 1000) mg/l\nMetoda wagowa","reference":"PB/FCH/2/C:18.06.2018","norm_bases":["PB/FCH/2/C:18.06.2018"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Substancje ekstrahujące się eterem naftowym\nZakres (3,0 – 1000) mg/l\nMetoda wagowa PB/FCH/2/C:18.06.2018 Woda, Woda do spozycia przez ludzi, Scieki Substancje ekstrahujace sie eterem naftowym\nZakres (3,0 – 1000) mg/l\nMetoda wagowa PB/FCH/2/C:18.06.2018","categories":["water"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(3,0 – 1000) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Substances extractable with petroleum ether Gravimetric method Range PB/FCH/2/C:18.06.2018","technique_en":"Gravimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(3,0 – 1000) mg/l"}],"search_zh":"水、生活饮用水、废水 石油醚可萃取物 重量法 范围 PB/FCH/2/C:18.06.2018","technique_zh":"重量法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"石油醚可萃取物"},{"_id":"6a832b7f884ede9a1b2c551c","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Twardość węglanowa, Twardość niewęglanowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Twardość węglanowa, Twardość niewęglanowa (z obliczeń)","reference":"PB/FCH/34/B:30.03.2012","norm_bases":["PB/FCH/34/B:30.03.2012"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Twardość węglanowa, Twardość niewęglanowa (z obliczeń) PB/FCH/34/B:30.03.2012 Woda, Woda do spozycia przez ludzi, Scieki Twardosc weglanowa, Twardosc nieweglanowa (z obliczen) PB/FCH/34/B:30.03.2012","categories":["water"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbonate hardness, Non-carbonate hardness (calculated)","search_en":"Water, Water intended for human consumption, Wastewater Carbonate hardness, Non-carbonate hardness (calculated) PB/FCH/34/B:30.03.2012","test_object_en":"Water, Water intended for human consumption, Wastewater","search_zh":"水、生活饮用水、废水 碳酸盐硬度、非碳酸盐硬度（由计算得出） PB/FCH/34/B:30.03.2012","test_object_zh":"水、生活饮用水、废水","methodology_zh":"碳酸盐硬度、非碳酸盐硬度（由计算得出）"},{"_id":"6a832b7f884ede9a1b2c551d","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Zasadowość","parameters":[{"name":"Zakres","range":"(0,7 – 400) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zasadowość\nZakres (0,7 – 400) mg/l\nMetoda spektrofotometryczna","reference":"PB/FCH/102/A:01.07.2020","norm_bases":["PB/FCH/102/A:01.07.2020"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Zasadowość\nZakres (0,7 – 400) mg/l\nMetoda spektrofotometryczna PB/FCH/102/A:01.07.2020 Woda, Woda do spozycia przez ludzi, Scieki Zasadowosc\nZakres (0,7 – 400) mg/l\nMetoda spektrofotometryczna PB/FCH/102/A:01.07.2020","categories":["water"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Alkalinity","parameters_en":[{"name":"Range","range":"(0,7 – 400) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Alkalinity Spectrophotometric method Range PB/FCH/102/A:01.07.2020","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,7 – 400) mg/l"}],"search_zh":"水、生活饮用水、废水 碱度 分光光度法 范围 PB/FCH/102/A:01.07.2020","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"碱度"},{"_id":"6a832b7f884ede9a1b2c551e","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Zasadowość mineralna","parameters":[{"name":"Zakres","range":"(0,1 – 100) mmol/l"},{"name":"Zakres","range":"(5,0 – 5000) mg/l CaCO3"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zasadowość mineralna\nZakres:\nZakres (0,1 – 100) mmol/l\nZakres (5,0 – 5000) mg/l CaCO3\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Zasadowość mineralna\nZakres:\nZakres (0,1 – 100) mmol/l\nZakres (5,0 – 5000) mg/l CaCO3\nMetoda miareczkowania potencjometrycznego PN-EN ISO 9963-1:2001+Ap1:2004 Woda, Woda do spozycia przez ludzi, Scieki Zasadowosc mineralna\nZakres:\nZakres (0,1 – 100) mmol/l\nZakres (5,0 – 5000) mg/l CaCO3\nMetoda miareczkowania potencjometrycznego PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral alkalinity","parameters_en":[{"name":"Range","range":"(0,1 – 100) mmol/l"},{"name":"Range","range":"(5,0 – 5000) mg/l CaCO3"}],"search_en":"Water, Water intended for human consumption, Wastewater Mineral alkalinity Potentiometric titration method Range Range PN-EN ISO 9963-1:2001+Ap1:2004","technique_en":"Potentiometric titration method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,1 – 100) mmol/l"},{"name":"范围","range":"(5,0 – 5000) mg/l CaCO3"}],"search_zh":"水、生活饮用水、废水 矿物碱度 电位滴定法 范围 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"电位滴定法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"矿物碱度"},{"_id":"6a832b7f884ede9a1b2c551f","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Zasadowość ogólna","parameters":[{"name":"Zakres","range":"(0,1 – 100) mmol/l"},{"name":"Zakres","range":"(5,0 – 5000) mg/l CaCO3"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zasadowość ogólna\nZakres:\nZakres (0,1 – 100) mmol/l\nZakres (5,0 – 5000) mg/l CaCO3\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Zasadowość ogólna\nZakres:\nZakres (0,1 – 100) mmol/l\nZakres (5,0 – 5000) mg/l CaCO3\nMetoda miareczkowania potencjometrycznego PN-EN ISO 9963-1:2001+Ap1:2004 Woda, Woda do spozycia przez ludzi, Scieki Zasadowosc ogolna\nZakres:\nZakres (0,1 – 100) mmol/l\nZakres (5,0 – 5000) mg/l CaCO3\nMetoda miareczkowania potencjometrycznego PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total alkalinity","parameters_en":[{"name":"Range","range":"(0,1 – 100) mmol/l"},{"name":"Range","range":"(5,0 – 5000) mg/l CaCO3"}],"search_en":"Water, Water intended for human consumption, Wastewater Total alkalinity Potentiometric titration method Range Range PN-EN ISO 9963-1:2001+Ap1:2004","technique_en":"Potentiometric titration method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,1 – 100) mmol/l"},{"name":"范围","range":"(5,0 – 5000) mg/l CaCO3"}],"search_zh":"水、生活饮用水、废水 总碱度 电位滴定法 范围 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"电位滴定法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"总碱度"},{"_id":"6a832b7f884ede9a1b2c5520","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2 – 4000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2 – 4000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Zawiesiny ogólne\nZakres (2 – 4000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Woda do spozycia przez ludzi, Scieki Zawiesiny ogolne\nZakres (2 – 4000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2 – 4000) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2 – 4000) mg/l"}],"search_zh":"水、生活饮用水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c5521","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie fluorków","parameters":[{"name":"Zakres","range":"(0,05 – 5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fluorków\nZakres (0,05 – 5) mg/l\nMetoda spektrofotometryczna","reference":"EFO/PB/27/A: 12.12.2023","norm_bases":["EFO/PB/27/A: 12.12.2023"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie fluorków\nZakres (0,05 – 5) mg/l\nMetoda spektrofotometryczna EFO/PB/27/A: 12.12.2023 Woda, Woda do spozycia przez ludzi, Scieki Stezenie fluorkow\nZakres (0,05 – 5) mg/l\nMetoda spektrofotometryczna EFO/PB/27/A: 12.12.2023","categories":["water"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluoride concentration","parameters_en":[{"name":"Range","range":"(0,05 – 5) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Fluoride concentration Spectrophotometric method Range EFO/PB/27/A: 12.12.2023","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,05 – 5) mg/l"}],"search_zh":"水、生活饮用水、废水 氟化物浓度 分光光度法 范围 EFO/PB/27/A: 12.12.2023","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"氟化物浓度"},{"_id":"6a832b7f884ede9a1b2c5522","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie adsorbowalnych związków chloroorganicznych (AOX)","parameters":[{"name":"Zakres","range":"(0,010 – 10) mg/l"}],"technique":"Metoda kulometryczna","techniques":["Metoda kulometryczna"],"computed":[],"activity":"Stężenie adsorbowalnych związków chloroorganicznych (AOX)\nZakres (0,010 – 10) mg/l\nMetoda kulometryczna","reference":"PN-EN ISO 9562:2007","norm_bases":["PN-EN ISO 9562:2007"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie adsorbowalnych związków chloroorganicznych (AOX)\nZakres (0,010 – 10) mg/l\nMetoda kulometryczna PN-EN ISO 9562:2007 Woda, Scieki Stezenie adsorbowalnych zwiazkow chloroorganicznych (AOX)\nZakres (0,010 – 10) mg/l\nMetoda kulometryczna PN-EN ISO 9562:2007","categories":["water"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Adsorbable organically bound halogens (AOX) concentration","parameters_en":[{"name":"Range","range":"(0,010 – 10) mg/l"}],"search_en":"Water, Wastewater Adsorbable organically bound halogens (AOX) concentration Coulometric method Range PN-EN ISO 9562:2007","technique_en":"Coulometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 10) mg/l"}],"search_zh":"水、污水 可吸附有机卤化物（AOX）浓度 范围 PN-EN ISO 9562:2007","test_object_zh":"水、污水","methodology_zh":"可吸附有机卤化物（AOX）浓度"},{"_id":"6a832b7f884ede9a1b2c5523","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,0050 – 50) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,0050 – 50) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14402:2004, pkt.4","norm_bases":["PN-EN ISO 14402:2004, pkt.4"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Indeks fenolowy\nZakres (0,0050 – 50) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 14402:2004, pkt.4 Woda, Scieki Indeks fenolowy\nZakres (0,0050 – 50) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 14402:2004, pkt.4","categories":["water"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,0050 – 50) mg/l"}],"search_en":"Water, Wastewater Phenol index Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 14402:2004, pkt.4","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,0050 – 50) mg/l"}],"search_zh":"水、污水 酚指数 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 14402:2004, pkt.4","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水","methodology_zh":"酚指数"},{"_id":"6a832b7f884ede9a1b2c5524","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Indeks oleju mineralnego (C10-C40, C12-C35, C12-C30)","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego (C10-C40, C12-C35, C12-C30)\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Indeks oleju mineralnego (C10-C40, C12-C35, C12-C30)\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, Scieki Indeks oleju mineralnego (C10-C40, C12-C35, C12-C30)\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index (C10-C40, C12-C35, C12-C30)","parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/l"}],"search_en":"Water, Wastewater Mineral oil index (C10-C40, C12-C35, C12-C30) Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/l"}],"search_zh":"水、污水 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、污水"},{"_id":"6a832b7f884ede9a1b2c5525","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stałe związki rozpuszczone/TDS","parameters":[{"name":"Zakres","range":"(10 – 50000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stałe związki rozpuszczone/TDS\nZakres (10 – 50000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stałe związki rozpuszczone/TDS\nZakres (10 – 50000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda, Scieki Stale zwiazki rozpuszczone/TDS\nZakres (10 – 50000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids/TDS","parameters_en":[{"name":"Range","range":"(10 – 50000) mg/l"}],"search_en":"Water, Wastewater Total dissolved solids/TDS Gravimetric method Range PN-EN 15216:2022-03","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(10 – 50000) mg/l"}],"search_zh":"水、污水 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a832b7f884ede9a1b2c5526","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Substancje rozpuszczone ogólne, mineralne, lotne","parameters":[{"name":"Zakres","range":"(10 – 50000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone ogólne, mineralne, lotne\nZakres (10 – 50000) mg/l\nMetoda wagowa","reference":"PN-78/C-04541","norm_bases":["PN-78/C-04541"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Substancje rozpuszczone ogólne, mineralne, lotne\nZakres (10 – 50000) mg/l\nMetoda wagowa PN-78/C-04541 Woda, Scieki Substancje rozpuszczone ogolne, mineralne, lotne\nZakres (10 – 50000) mg/l\nMetoda wagowa PN-78/C-04541","categories":["water"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total, mineral and volatile dissolved solids","parameters_en":[{"name":"Range","range":"(10 – 50000) mg/l"}],"search_en":"Water, Wastewater Total, mineral and volatile dissolved solids Gravimetric method Range PN-78/C-04541","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(10 – 50000) mg/l"}],"search_zh":"水、污水 重量法 范围 PN-78/C-04541","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a832b7f884ede9a1b2c5527","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Sucha pozostałość, pozostałość po prażeniu, straty prażenia","parameters":[{"name":"Zakres","range":"(10 – 50000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość, pozostałość po prażeniu, straty prażenia\nZakres (10 – 50000) mg/l\nMetoda wagowa","reference":"PN-78/C-04541","norm_bases":["PN-78/C-04541"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Sucha pozostałość, pozostałość po prażeniu, straty prażenia\nZakres (10 – 50000) mg/l\nMetoda wagowa PN-78/C-04541 Woda, Scieki Sucha pozostalosc, pozostalosc po prazeniu, straty prazenia\nZakres (10 – 50000) mg/l\nMetoda wagowa PN-78/C-04541","categories":["water"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue, residue on ignition, loss on ignition","parameters_en":[{"name":"Range","range":"(10 – 50000) mg/l"}],"search_en":"Water, Wastewater Dry residue, residue on ignition, loss on ignition Gravimetric method Range PN-78/C-04541","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(10 – 50000) mg/l"}],"search_zh":"水、污水 重量法 范围 PN-78/C-04541","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a832b7f884ede9a1b2c5528","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,5 – 2000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,5 – 2000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (0,5 – 2000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (0,5 – 2000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 2000) mg/l"}],"search_en":"Water, Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,5 – 2000) mg/l"}],"search_zh":"水、污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a832b7f884ede9a1b2c5529","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,50 – 2000) mg/l"},{"name":"Stężenie jonu amonowego"},{"name":"Zakres","range":"(0,64 – 2560) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (0,50 – 2000) mg/l\nStężenie jonu amonowego\nZakres (0,64 – 2560) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres:\nZakres (0,50 – 2000) mg/l\nStężenie jonu amonowego\nZakres (0,64 – 2560) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, Scieki Stezenie azotu amonowego\nZakres:\nZakres (0,50 – 2000) mg/l\nStezenie jonu amonowego\nZakres (0,64 – 2560) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 2000) mg/l"},{"name":"Ammonium ion concentration"},{"name":"Range","range":"(0,64 – 2560) mg/l"}],"search_en":"Water, Wastewater Ammonium nitrogen concentration Titrimetric method Range Ammonium ion concentration Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 2000) mg/l"},{"name":"铵离子浓度"},{"name":"范围","range":"(0,64 – 2560) mg/l"}],"search_zh":"水、污水 氨氮浓度 滴定法 范围 铵离子浓度 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a832b7f884ede9a1b2c552a","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie amoniaku niejonowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie amoniaku niejonowego (z obliczeń)","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie amoniaku niejonowego (z obliczeń) PN-ISO 5664:2002 Woda, Scieki Stezenie amoniaku niejonowego (z obliczen) PN-ISO 5664:2002","categories":["water"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Un-ionised ammonia concentration (calculated)","search_en":"Water, Wastewater Un-ionised ammonia concentration (calculated) PN-ISO 5664:2002","test_object_en":"Water, Wastewater","search_zh":"水、污水 非离子氨浓度（由计算得出） PN-ISO 5664:2002","test_object_zh":"水、污水","methodology_zh":"非离子氨浓度（由计算得出）"},{"_id":"6a832b7f884ede9a1b2c552b","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu ogólnego, Stężenie azot organicznego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego, Stężenie azot organicznego (z obliczeń)","reference":"PB/FCH/6/D:10.04.2017","norm_bases":["PB/FCH/6/D:10.04.2017"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu ogólnego, Stężenie azot organicznego (z obliczeń) PB/FCH/6/D:10.04.2017 Woda, Scieki Stezenie azotu ogolnego, Stezenie azot organicznego (z obliczen) PB/FCH/6/D:10.04.2017","categories":["water"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration, Organic nitrogen concentration (calculated)","search_en":"Water, Wastewater Total nitrogen concentration, Organic nitrogen concentration (calculated) PB/FCH/6/D:10.04.2017","test_object_en":"Water, Wastewater","search_zh":"水、污水 PB/FCH/6/D:10.04.2017","test_object_zh":"水、污水"},{"_id":"6a832b7f884ede9a1b2c552c","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie chlorobenzenów","parameters":[{"name":"Monochlorobenzen","range":"(0,001 – 1,0) μg/l"},{"name":"Zakres","range":"1,2-Dichlorobenzen (0,001 – 1,0) μg/l"},{"name":"1,3- Dichlorobenzen","range":"(0,001 – 1,0) μg/l"},{"name":"1,4- Dichlorobenzen","range":"(0,001 – 1,0) μg/l"},{"name":"1,2,3-Trichlorobenzen","range":"(0,001 – 1,0) μg/l"},{"name":"1,2,4-Trichlorobenzen","range":"(0,001 – 1,0) μg/l"},{"name":"1,3,5-Trichlorobenzen","range":"(0,001 – 1,0) μg/l"},{"name":"2,4,5-Trichlorobenzen","range":"(0,001 – 1,0) μg/l"},{"name":"1,2,3,4-Tetrachlorobenzen","range":"(0,001 – 1,0) μg/l"},{"name":"1,2,3,5-Tetrachlorobenzen","range":"(0,001 – 1,0) μg/l"},{"name":"1,2,4,5-Tetrachlorobenzen","range":"(0,001 – 1,0) μg/l"},{"name":"Pentachlorobenzen","range":"(0,001 – 1,0) μg/l"},{"name":"Heksachlorobenzen (HCB)","range":"(0,001 – 1,0) μg/l"},{"name":"Suma (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Stężenie chlorobenzenów\nZakres:\nMonochlorobenzen (0,001 – 1,0) μg/l\nZakres 1,2-Dichlorobenzen (0,001 – 1,0) μg/l\n1,3- Dichlorobenzen (0,001 – 1,0) μg/l\n1,4- Dichlorobenzen (0,001 – 1,0) μg/l\n1,2,3-Trichlorobenzen (0,001 – 1,0) μg/l\n1,2,4-Trichlorobenzen (0,001 – 1,0) μg/l\n1,3,5-Trichlorobenzen (0,001 – 1,0) μg/l\n2,4,5-Trichlorobenzen (0,001 – 1,0) μg/l\n1,2,3,4-Tetrachlorobenzen (0,001 – 1,0) μg/l\n1,2,3,5-Tetrachlorobenzen (0,001 – 1,0) μg/l\n1,2,4,5-Tetrachlorobenzen (0,001 – 1,0) μg/l\nPentachlorobenzen (0,001 – 1,0) μg/l\nHeksachlorobenzen (HCB) (0,001 – 1,0) μg/l\nSuma (z obliczeń)\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"EFO/PB/24/A: 18.09.2023 | na podstawie | PN-EN ISO 6468:2002","norm_bases":["EFO/PB/24/A: 18.09.2023","na podstawie","PN-EN ISO 6468:2002"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie chlorobenzenów\nZakres:\nMonochlorobenzen (0,001 – 1,0) μg/l\nZakres 1,2-Dichlorobenzen (0,001 – 1,0) μg/l\n1,3- Dichlorobenzen (0,001 – 1,0) μg/l\n1,4- Dichlorobenzen (0,001 – 1,0) μg/l\n1,2,3-Trichlorobenzen (0,001 – 1,0) μg/l\n1,2,4-Trichlorobenzen (0,001 – 1,0) μg/l\n1,3,5-Trichlorobenzen (0,001 – 1,0) μg/l\n2,4,5-Trichlorobenzen (0,001 – 1,0) μg/l\n1,2,3,4-Tetrachlorobenzen (0,001 – 1,0) μg/l\n1,2,3,5-Tetrachlorobenzen (0,001 – 1,0) μg/l\n1,2,4,5-Tetrachlorobenzen (0,001 – 1,0) μg/l\nPentachlorobenzen (0,001 – 1,0) μg/l\nHeksachlorobenzen (HCB) (0,001 – 1,0) μg/l\nSuma (z obliczeń)\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) EFO/PB/24/A: 18.09.2023 | na podstawie | PN-EN ISO 6468:2002 Woda, Scieki Stezenie chlorobenzenow\nZakres:\nMonochlorobenzen (0,001 – 1,0) μg/l\nZakres 1,2-Dichlorobenzen (0,001 – 1,0) μg/l\n1,3- Dichlorobenzen (0,001 – 1,0) μg/l\n1,4- Dichlorobenzen (0,001 – 1,0) μg/l\n1,2,3-Trichlorobenzen (0,001 – 1,0) μg/l\n1,2,4-Trichlorobenzen (0,001 – 1,0) μg/l\n1,3,5-Trichlorobenzen (0,001 – 1,0) μg/l\n2,4,5-Trichlorobenzen (0,001 – 1,0) μg/l\n1,2,3,4-Tetrachlorobenzen (0,001 – 1,0) μg/l\n1,2,3,5-Tetrachlorobenzen (0,001 – 1,0) μg/l\n1,2,4,5-Tetrachlorobenzen (0,001 – 1,0) μg/l\nPentachlorobenzen (0,001 – 1,0) μg/l\nHeksachlorobenzen (HCB) (0,001 – 1,0) μg/l\nSuma (z obliczen)\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) EFO/PB/24/A: 18.09.2023 | na podstawie | PN-EN ISO 6468:2002","categories":["water"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorobenzene concentration","parameters_en":[{"name":"Monochlorobenzene","range":"(0,001 – 1,0) μg/l"},{"name":"Range","range":"1,2-Dichlorobenzen (0,001 – 1,0) μg/l"},{"name":"1,3- Dichlorobenzene","range":"(0,001 – 1,0) μg/l"},{"name":"1,4- Dichlorobenzene","range":"(0,001 – 1,0) μg/l"},{"name":"1,2,3-Trichlorobenzene","range":"(0,001 – 1,0) μg/l"},{"name":"1,2,4-Trichlorobenzene","range":"(0,001 – 1,0) μg/l"},{"name":"1,3,5-Trichlorobenzene","range":"(0,001 – 1,0) μg/l"},{"name":"2,4,5-Trichlorobenzene","range":"(0,001 – 1,0) μg/l"},{"name":"1,2,3,4-Tetrachlorobenzene","range":"(0,001 – 1,0) μg/l"},{"name":"1,2,3,5-Tetrachlorobenzene","range":"(0,001 – 1,0) μg/l"},{"name":"1,2,4,5-Tetrachlorobenzene","range":"(0,001 – 1,0) μg/l"},{"name":"Pentachlorobenzene","range":"(0,001 – 1,0) μg/l"},{"name":"Hexachlorobenzene (HCB)","range":"(0,001 – 1,0) μg/l"},{"name":"Sum (calculated)"}],"search_en":"Water, Wastewater Chlorobenzene concentration Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) Monochlorobenzene Range 1,3- Dichlorobenzene 1,4- Dichlorobenzene 1,2,3-Trichlorobenzene 1,2,4-Trichlorobenzene 1,3,5-Trichlorobenzene 2,4,5-Trichlorobenzene 1,2,3,4-Tetrachlorobenzene 1,2,3,5-Tetrachlorobenzene 1,2,4,5-Tetrachlorobenzene Pentachlorobenzene Hexachlorobenzene (HCB) Sum (calculated) EFO/PB/24/A: 18.09.2023 | na podstawie | PN-EN ISO 6468:2002","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"Monochlorobenzen","range":"(0,001 – 1,0) μg/l"},{"name":"范围","range":"1,2-Dichlorobenzen (0,001 – 1,0) μg/l"},{"name":"1,3- Dichlorobenzen","range":"(0,001 – 1,0) μg/l"},{"name":"1,4- Dichlorobenzen","range":"(0,001 – 1,0) μg/l"},{"name":"1,2,3-Trichlorobenzen","range":"(0,001 – 1,0) μg/l"},{"name":"1,2,4-三氯苯","range":"(0,001 – 1,0) μg/l"},{"name":"1,3,5-三氯苯","range":"(0,001 – 1,0) μg/l"},{"name":"2,4,5-Trichlorobenzen","range":"(0,001 – 1,0) μg/l"},{"name":"1,2,3,4-Tetrachlorobenzen","range":"(0,001 – 1,0) μg/l"},{"name":"1,2,3,5-Tetrachlorobenzen","range":"(0,001 – 1,0) μg/l"},{"name":"1,2,4,5-Tetrachlorobenzen","range":"(0,001 – 1,0) μg/l"},{"name":"五氯苯","range":"(0,001 – 1,0) μg/l"},{"name":"六氯苯（HCB）","range":"(0,001 – 1,0) μg/l"},{"name":"总量（由计算得出）"}],"search_zh":"水、污水 氯苯类浓度 气相色谱-串联质谱法（GC-MS-MS） 范围 1,2,4-三氯苯 1,3,5-三氯苯 五氯苯 六氯苯（HCB） 总量（由计算得出） EFO/PB/24/A: 18.09.2023 | na podstawie | PN-EN ISO 6468:2002","test_object_zh":"水、污水","technique_zh":"气相色谱-串联质谱法（GC-MS-MS）","methodology_zh":"氯苯类浓度"},{"_id":"6a832b7f884ede9a1b2c552d","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie detergentów anionowych (anionowych substancji powierzchniowo czynnych – ASPC)","parameters":[{"name":"Zakres","range":"(0,05 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie detergentów anionowych (anionowych substancji powierzchniowo czynnych – ASPC)\nZakres (0,05 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PB/FCH/69/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 332","norm_bases":["PB/FCH/69/A:10.04.2012","na podstawie testu kuwetowego HACH Lange nr LCK 332"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie detergentów anionowych (anionowych substancji powierzchniowo czynnych – ASPC)\nZakres (0,05 – 200) mg/l\nMetoda spektrofotometryczna PB/FCH/69/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 332 Woda, Scieki Stezenie detergentow anionowych (anionowych substancji powierzchniowo czynnych – ASPC)\nZakres (0,05 – 200) mg/l\nMetoda spektrofotometryczna PB/FCH/69/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 332","categories":["water"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anionic detergent concentration (anionic surfactants – ASPC)","parameters_en":[{"name":"Range","range":"(0,05 – 200) mg/l"}],"search_en":"Water, Wastewater Anionic detergent concentration (anionic surfactants – ASPC) Spectrophotometric method Range PB/FCH/69/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 332","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,05 – 200) mg/l"}],"search_zh":"水、污水 阴离子洗涤剂（阴离子表面活性物质 ASPC）浓度 分光光度法 范围 PB/FCH/69/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 332","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"阴离子洗涤剂（阴离子表面活性物质 ASPC）浓度"},{"_id":"6a832b7f884ede9a1b2c552e","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie detergentów kationowych (kationowych substancji powierzchniowo czynnych – KSPC)","parameters":[{"name":"Zakres","range":"(0,20 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie detergentów kationowych (kationowych substancji powierzchniowo czynnych – KSPC)\nZakres (0,20 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PB/FCH/71/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 331","norm_bases":["PB/FCH/71/A:10.04.2012","na podstawie testu kuwetowego HACH Lange nr LCK 331"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie detergentów kationowych (kationowych substancji powierzchniowo czynnych – KSPC)\nZakres (0,20 – 200) mg/l\nMetoda spektrofotometryczna PB/FCH/71/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 331 Woda, Scieki Stezenie detergentow kationowych (kationowych substancji powierzchniowo czynnych – KSPC)\nZakres (0,20 – 200) mg/l\nMetoda spektrofotometryczna PB/FCH/71/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 331","categories":["water"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cationic detergent concentration (cationic surfactants – KSPC)","parameters_en":[{"name":"Range","range":"(0,20 – 200) mg/l"}],"search_en":"Water, Wastewater Cationic detergent concentration (cationic surfactants – KSPC) Spectrophotometric method Range PB/FCH/71/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 331","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,20 – 200) mg/l"}],"search_zh":"水、污水 分光光度法 范围 PB/FCH/71/A:10.04.2012 | na podstawie testu kuwetowego HACH Lange nr LCK 331","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a832b7f884ede9a1b2c552f","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie formaldehydu","parameters":[{"name":"Zakres","range":"(0,01 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie formaldehydu\nZakres (0,01 – 100) mg/l\nMetoda spektrofotometryczna","reference":"EFO/PB/47/A:05.05.2025 na podstawie testu kuwetowego HACH Lange nr LCK 325","norm_bases":["EFO/PB/47/A:05.05.2025 na podstawie testu kuwetowego HACH Lange nr LCK 325"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie formaldehydu\nZakres (0,01 – 100) mg/l\nMetoda spektrofotometryczna EFO/PB/47/A:05.05.2025 na podstawie testu kuwetowego HACH Lange nr LCK 325 Woda, Scieki Stezenie formaldehydu\nZakres (0,01 – 100) mg/l\nMetoda spektrofotometryczna EFO/PB/47/A:05.05.2025 na podstawie testu kuwetowego HACH Lange nr LCK 325","categories":["water"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde concentration","parameters_en":[{"name":"Range","range":"(0,01 – 100) mg/l"}],"search_en":"Water, Wastewater Formaldehyde concentration Spectrophotometric method Range EFO/PB/47/A:05.05.2025 na podstawie testu kuwetowego HACH Lange nr LCK 325","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,01 – 100) mg/l"}],"search_zh":"水、污水 甲醛浓度 分光光度法 范围 EFO/PB/47/A:05.05.2025 na podstawie testu kuwetowego HACH Lange nr LCK 325","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"甲醛浓度"},{"_id":"6a832b7f884ede9a1b2c5530","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,016 – 65) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,016 – 65) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,016 – 65) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,016 – 65) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,016 – 65) mg/l"}],"search_en":"Water, Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,016 – 65) mg/l"}],"search_zh":"水、污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a832b7f884ede9a1b2c5531","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Zawiesiny łatwoopadające","parameters":[{"name":"Zakres","range":"(0,50 – 200) ml/l"}],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Zawiesiny łatwoopadające\nZakres (0,50 – 200) ml/l\nMetoda objętościowa","reference":"PN-72/C-04559/03","norm_bases":["PN-72/C-04559/03"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Zawiesiny łatwoopadające\nZakres (0,50 – 200) ml/l\nMetoda objętościowa PN-72/C-04559/03 Woda, Scieki Zawiesiny latwoopadajace\nZakres (0,50 – 200) ml/l\nMetoda objetosciowa PN-72/C-04559/03","categories":["water"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Settleable solids","parameters_en":[{"name":"Range","range":"(0,50 – 200) ml/l"}],"search_en":"Water, Wastewater Settleable solids Volumetric method Range PN-72/C-04559/03","technique_en":"Volumetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,50 – 200) ml/l"}],"search_zh":"水、污水 易沉降悬浮物 容量法 范围 PN-72/C-04559/03","test_object_zh":"水、污水","technique_zh":"容量法","methodology_zh":"易沉降悬浮物"},{"_id":"6a832b7f884ede9a1b2c5532","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,20 – 100) mg/l"},{"name":"Stężenie jonu amonowego"},{"name":"Zakres","range":"(0,26 – 130) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (0,20 – 100) mg/l\nStężenie jonu amonowego\nZakres (0,26 – 130) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 11732:2007","norm_bases":["PN-EN ISO 11732:2007"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres:\nZakres (0,20 – 100) mg/l\nStężenie jonu amonowego\nZakres (0,26 – 130) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 11732:2007 Scieki Stezenie azotu amonowego\nZakres:\nZakres (0,20 – 100) mg/l\nStezenie jonu amonowego\nZakres (0,26 – 130) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 11732:2007","categories":["water"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,20 – 100) mg/l"},{"name":"Ammonium ion concentration"},{"name":"Range","range":"(0,26 – 130) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range Ammonium ion concentration Range PN-EN ISO 11732:2007","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 100) mg/l"},{"name":"铵离子浓度"},{"name":"范围","range":"(0,26 – 130) mg/l"}],"search_zh":"污水 氨氮浓度 连续流动分析（CFA）分光光度检测法 范围 铵离子浓度 范围 PN-EN ISO 11732:2007","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"污水"},{"_id":"6a832b7f884ede9a1b2c5533","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie amoniaku niejonowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie amoniaku niejonowego (z obliczeń)","reference":"PN-EN ISO 11732:2007","norm_bases":["PN-EN ISO 11732:2007"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie amoniaku niejonowego (z obliczeń) PN-EN ISO 11732:2007 Scieki Stezenie amoniaku niejonowego (z obliczen) PN-EN ISO 11732:2007","categories":["water"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Un-ionised ammonia concentration (calculated)","search_en":"Wastewater Un-ionised ammonia concentration (calculated) PN-EN ISO 11732:2007","test_object_en":"Wastewater","search_zh":"污水 非离子氨浓度（由计算得出） PN-EN ISO 11732:2007","test_object_zh":"污水","methodology_zh":"非离子氨浓度（由计算得出）"},{"_id":"6a832b7f884ede9a1b2c5534","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chromu (VI)","parameters":[{"name":"Zakres","range":"(0,010 – 5,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu (VI)\nZakres (0,010 – 5,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-77/C-04604/08","norm_bases":["PN-77/C-04604/08"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chromu (VI)\nZakres (0,010 – 5,00) mg/l\nMetoda spektrofotometryczna PN-77/C-04604/08 Scieki Stezenie chromu (VI)\nZakres (0,010 – 5,00) mg/l\nMetoda spektrofotometryczna PN-77/C-04604/08","categories":["water"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) concentration","parameters_en":[{"name":"Range","range":"(0,010 – 5,00) mg/l"}],"search_en":"Wastewater Chromium(VI) concentration Spectrophotometric method Range PN-77/C-04604/08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 5,00) mg/l"}],"search_zh":"污水 六价铬浓度 分光光度法 范围 PN-77/C-04604/08","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"六价铬浓度"},{"_id":"6a832b7f884ede9a1b2c5535","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chromu (III) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chromu (III) (z obliczeń)","reference":"PN-77/C-04604/08","norm_bases":["PN-77/C-04604/08"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chromu (III) (z obliczeń) PN-77/C-04604/08 Scieki Stezenie chromu (III) (z obliczen) PN-77/C-04604/08","categories":["water"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium (III) concentration (calculated)","search_en":"Wastewater Chromium (III) concentration (calculated) PN-77/C-04604/08","test_object_en":"Wastewater","search_zh":"污水 铬(III)浓度（由计算得出） PN-77/C-04604/08","test_object_zh":"污水","methodology_zh":"铬(III)浓度（由计算得出）"},{"_id":"6a832b7f884ede9a1b2c5536","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie formaldehydu","parameters":[{"name":"Zakres","range":"(0,02 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie formaldehydu\nZakres (0,02 – 200) mg/l\nMetoda spektrofotometryczna","reference":"EFO/PB/46/A:05.05.2025 Dokumenty odniesienia","norm_bases":["EFO/PB/46/A:05.05.2025 Dokumenty odniesienia"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie formaldehydu\nZakres (0,02 – 200) mg/l\nMetoda spektrofotometryczna EFO/PB/46/A:05.05.2025 Dokumenty odniesienia Scieki Stezenie formaldehydu\nZakres (0,02 – 200) mg/l\nMetoda spektrofotometryczna EFO/PB/46/A:05.05.2025 Dokumenty odniesienia","categories":["water"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde concentration","parameters_en":[{"name":"Range","range":"(0,02 – 200) mg/l"}],"search_en":"Wastewater Formaldehyde concentration Spectrophotometric method Range EFO/PB/46/A:05.05.2025 Dokumenty odniesienia","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,02 – 200) mg/l"}],"search_zh":"污水 甲醛浓度 分光光度法 范围 EFO/PB/46/A:05.05.2025 Dokumenty odniesienia","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"甲醛浓度"},{"_id":"6a832b7f884ede9a1b2c5537","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu","reference":"PN-EN ISO 21268-2:2020-01","norm_bases":["PN-EN ISO 21268-2:2020-01"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Chemiczne zapotrzebowanie tlenu PN-EN ISO 21268-2:2020-01 Gleba, grunty Chemiczne zapotrzebowanie tlenu PN-EN ISO 21268-2:2020-01","categories":["environment"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand","search_en":"Soil, ground Chemical oxygen demand PN-EN ISO 21268-2:2020-01","test_object_en":"Soil, ground","search_zh":"土壤、土体 化学需氧量（COD） PN-EN ISO 21268-2:2020-01","test_object_zh":"土壤、土体","methodology_zh":"化学需氧量（COD）"},{"_id":"6a832b7f884ede9a1b2c5538","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(5,0 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zakres:\nChZT-Cr\nZakres (5,0 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN ISO 15705:2005","norm_bases":["PN ISO 15705:2005"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Zakres:\nChZT-Cr\nZakres (5,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN ISO 15705:2005 Gleba, grunty Zakres:\nChZT-Cr\nZakres (5,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN ISO 15705:2005","categories":["environment"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(5,0 – 10000) mg/l O2"}],"search_en":"Soil, ground Spectrophotometric method COD-Cr Range PN ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Soil, ground","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(5,0 – 10000) mg/l O2"}],"search_zh":"土壤、土体 分光光度法 化学需氧量（COD-Cr） 范围 PN ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c5539","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,0050 – 50) mg/l"},{"name":"CFA z detekcją spektrofotometryczną"}],"technique":"Metoda ciągłej analizy przepływowej","techniques":["Metoda ciągłej analizy przepływowej"],"computed":[],"activity":"Indeks fenolowy\nZakres:\nZakres (0,0050 – 50) mg/l\nCFA z detekcją spektrofotometryczną\nMetoda ciągłej analizy przepływowej","reference":"PN-EN ISO 21268-2:2020-01 | PN-EN ISO 14402:2004, pkt.4 | PN-EN 12457-4:2006","norm_bases":["PN-EN ISO 21268-2:2020-01","PN-EN ISO 14402:2004, pkt.4","PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Indeks fenolowy\nZakres:\nZakres (0,0050 – 50) mg/l\nCFA z detekcją spektrofotometryczną\nMetoda ciągłej analizy przepływowej PN-EN ISO 21268-2:2020-01 | PN-EN ISO 14402:2004, pkt.4 | PN-EN 12457-4:2006 Gleba, grunty Indeks fenolowy\nZakres:\nZakres (0,0050 – 50) mg/l\nCFA z detekcja spektrofotometryczna\nMetoda ciaglej analizy przeplywowej PN-EN ISO 21268-2:2020-01 | PN-EN ISO 14402:2004, pkt.4 | PN-EN 12457-4:2006","categories":["environment"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,0050 – 50) mg/l"},{"name":"CFA with spectrophotometric detection"}],"search_en":"Soil, ground Phenol index Continuous flow analysis method Range CFA with spectrophotometric detection PN-EN ISO 21268-2:2020-01 | PN-EN ISO 14402:2004, pkt.4 | PN-EN 12457-4:2006","technique_en":"Continuous flow analysis method","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(0,0050 – 50) mg/l"},{"name":"CFA z detekcją spektrofotometryczną"}],"search_zh":"土壤、土体 酚指数 连续流动分析法 范围 PN-EN ISO 21268-2:2020-01 | PN-EN ISO 14402:2004, pkt.4 | PN-EN 12457-4:2006","test_object_zh":"土壤、土体","methodology_zh":"酚指数","technique_zh":"连续流动分析法"},{"_id":"6a832b7f884ede9a1b2c553a","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 13,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 13,0\nMetoda potencjometryczna","reference":"PN-EN 12457-4:2006 | PN-EN ISO 21268-2:2020-01 | PN-EN ISO 10523:2012","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 21268-2:2020-01","PN-EN ISO 10523:2012"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty pH\nZakres 2,0 – 13,0\nMetoda potencjometryczna PN-EN 12457-4:2006 | PN-EN ISO 21268-2:2020-01 | PN-EN ISO 10523:2012 Gleba, grunty pH\nZakres 2,0 – 13,0\nMetoda potencjometryczna PN-EN 12457-4:2006 | PN-EN ISO 21268-2:2020-01 | PN-EN ISO 10523:2012","categories":["environment"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 13,0"}],"search_en":"Soil, ground pH Potentiometric method Range PN-EN 12457-4:2006 | PN-EN ISO 21268-2:2020-01 | PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Soil, ground","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 13,0"}],"search_zh":"土壤、土体 pH 值 电位法 范围 PN-EN 12457-4:2006 | PN-EN ISO 21268-2:2020-01 | PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c553b","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Przewodność elektryczna właściwa","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Przewodność elektryczna właściwa","reference":"PN-EN 12457-4:2006","norm_bases":["PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Przewodność elektryczna właściwa PN-EN 12457-4:2006 Gleba, grunty Przewodnosc elektryczna wlasciwa PN-EN 12457-4:2006","categories":["environment"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","search_en":"Soil, ground Electrical conductivity PN-EN 12457-4:2006","test_object_en":"Soil, ground","methodology_zh":"电导率","search_zh":"土壤、土体 电导率 PN-EN 12457-4:2006","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c553c","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"","parameters":[{"name":"Zakres","range":"(5 – 50000) μS/cm"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres (5 – 50000) μS/cm","reference":"PN-EN ISO 21268-2:2020-01","norm_bases":["PN-EN ISO 21268-2:2020-01"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Zakres (5 – 50000) μS/cm PN-EN ISO 21268-2:2020-01 Gleba, grunty Zakres (5 – 50000) μS/cm PN-EN ISO 21268-2:2020-01","categories":["environment"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(5 – 50000) μS/cm"}],"search_en":"Soil, ground Range PN-EN ISO 21268-2:2020-01","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(5 – 50000) μS/cm"}],"search_zh":"土壤、土体 范围 PN-EN ISO 21268-2:2020-01","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c553d","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"","parameters":[],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Metoda konduktometryczna PN-EN 27888:1999 Gleba, grunty Metoda konduktometryczna PN-EN 27888:1999","categories":["environment"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Soil, ground Conductometric method PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Soil, ground","search_zh":"土壤、土体 电导法 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c553e","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Stężenie anionów","parameters":[{"name":"Siarczany","range":"(1,0 – 500) mg/l"},{"name":"Chlorki","range":"(1,0 – 300) mg/l"},{"name":"Fluorki","range":"(0,10 – 2,0) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nSiarczany (1,0 – 500) mg/l\nChlorki (1,0 – 300) mg/l\nFluorki (0,10 – 2,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN 12457-4:2006 | PN-EN ISO 21268-2:2020-01 | PN-EN ISO 10304-1:2009","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 21268-2:2020-01","PN-EN ISO 10304-1:2009"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Stężenie anionów\nZakres:\nSiarczany (1,0 – 500) mg/l\nChlorki (1,0 – 300) mg/l\nFluorki (0,10 – 2,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN 12457-4:2006 | PN-EN ISO 21268-2:2020-01 | PN-EN ISO 10304-1:2009 Gleba, grunty Stezenie anionow\nZakres:\nSiarczany (1,0 – 500) mg/l\nChlorki (1,0 – 300) mg/l\nFluorki (0,10 – 2,0) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN 12457-4:2006 | PN-EN ISO 21268-2:2020-01 | PN-EN ISO 10304-1:2009","categories":["environment"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Sulfates","range":"(1,0 – 500) mg/l"},{"name":"Chlorides","range":"(1,0 – 300) mg/l"},{"name":"Fluorides","range":"(0,10 – 2,0) mg/l"}],"search_en":"Soil, ground Anion concentrations Ion chromatography with conductometric detection (IC-CD) Sulfates Chlorides Fluorides PN-EN 12457-4:2006 | PN-EN ISO 21268-2:2020-01 | PN-EN ISO 10304-1:2009","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Soil, ground","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"硫酸盐","range":"(1,0 – 500) mg/l"},{"name":"氯化物","range":"(1,0 – 300) mg/l"},{"name":"氟化物","range":"(0,10 – 2,0) mg/l"}],"search_zh":"土壤、土体 阴离子浓度 离子色谱-电导检测法（IC-CD） 硫酸盐 氯化物 氟化物 PN-EN 12457-4:2006 | PN-EN ISO 21268-2:2020-01 | PN-EN ISO 10304-1:2009","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c553f","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,20 – 100) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,20 – 100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 21268-2:2020-01 | PN-EN ISO 11732:2007","norm_bases":["PN-EN ISO 21268-2:2020-01","PN-EN ISO 11732:2007"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Stężenie azotu amonowego\nZakres (0,20 – 100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 21268-2:2020-01 | PN-EN ISO 11732:2007 Gleba, grunty Stezenie azotu amonowego\nZakres (0,20 – 100) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 21268-2:2020-01 | PN-EN ISO 11732:2007","categories":["environment"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,20 – 100) mg/l"}],"search_en":"Soil, ground Ammonium nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 21268-2:2020-01 | PN-EN ISO 11732:2007","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Soil, ground","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 100) mg/l"}],"search_zh":"土壤、土体 氨氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 21268-2:2020-01 | PN-EN ISO 11732:2007","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c5540","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,5 – 2000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,5 – 2000) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 21268-2:2020-01 | PN-ISO 5664:2002","norm_bases":["PN-EN ISO 21268-2:2020-01","PN-ISO 5664:2002"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Stężenie azotu amonowego\nZakres (0,5 – 2000) mg/l\nMetoda miareczkowa PN-EN ISO 21268-2:2020-01 | PN-ISO 5664:2002 Gleba, grunty Stezenie azotu amonowego\nZakres (0,5 – 2000) mg/l\nMetoda miareczkowa PN-EN ISO 21268-2:2020-01 | PN-ISO 5664:2002","categories":["environment"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 2000) mg/l"}],"search_en":"Soil, ground Ammonium nitrogen concentration Titrimetric method Range PN-EN ISO 21268-2:2020-01 | PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Soil, ground","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,5 – 2000) mg/l"}],"search_zh":"土壤、土体 氨氮浓度 滴定法 范围 PN-EN ISO 21268-2:2020-01 | PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c5541","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,20 – 100) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,20 – 100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 21268-2:2020-01 | PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 21268-2:2020-01","PN-EN ISO 13395:2001"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Stężenie azotu azotanowego\nZakres (0,20 – 100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 21268-2:2020-01 | PN-EN ISO 13395:2001 Gleba, grunty Stezenie azotu azotanowego\nZakres (0,20 – 100) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 21268-2:2020-01 | PN-EN ISO 13395:2001","categories":["environment"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,20 – 100) mg/l"}],"search_en":"Soil, ground Nitrate nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 21268-2:2020-01 | PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Soil, ground","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 100) mg/l"}],"search_zh":"土壤、土体 硝态氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 21268-2:2020-01 | PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c5542","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,020 – 2,50) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,020 – 2,50) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 21268-2:2020-01 | PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 21268-2:2020-01","PN-EN ISO 13395:2001"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Stężenie azotu azotynowego\nZakres (0,020 – 2,50) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 21268-2:2020-01 | PN-EN ISO 13395:2001 Gleba, grunty Stezenie azotu azotynowego\nZakres (0,020 – 2,50) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 21268-2:2020-01 | PN-EN ISO 13395:2001","categories":["environment"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,020 – 2,50) mg/l"}],"search_en":"Soil, ground Nitrite nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 21268-2:2020-01 | PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Soil, ground","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 2,50) mg/l"}],"search_zh":"土壤、土体 亚硝态氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 21268-2:2020-01 | PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c5543","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,5 – 850) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,5 – 850) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 21268-2:2020-01 | PN-EN 25663:2001","norm_bases":["PN-EN ISO 21268-2:2020-01","PN-EN 25663:2001"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Stężenie azotu Kjeldahla\nZakres (0,5 – 850) mg/l\nMetoda miareczkowa PN-EN ISO 21268-2:2020-01 | PN-EN 25663:2001 Gleba, grunty Stezenie azotu Kjeldahla\nZakres (0,5 – 850) mg/l\nMetoda miareczkowa PN-EN ISO 21268-2:2020-01 | PN-EN 25663:2001","categories":["environment"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 850) mg/l"}],"search_en":"Soil, ground Kjeldahl nitrogen concentration Titrimetric method Range PN-EN ISO 21268-2:2020-01 | PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Soil, ground","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,5 – 850) mg/l"}],"search_zh":"土壤、土体 凯氏氮浓度 滴定法 范围 PN-EN ISO 21268-2:2020-01 | PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c5544","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Azot ogólny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Azot ogólny (z obliczeń)","reference":"PN-EN ISO 21268-2:2020-01 PB/FCH/6/D:10.04.2017","norm_bases":["PN-EN ISO 21268-2:2020-01 PB/FCH/6/D:10.04.2017"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Azot ogólny (z obliczeń) PN-EN ISO 21268-2:2020-01 PB/FCH/6/D:10.04.2017 Gleba, grunty Azot ogolny (z obliczen) PN-EN ISO 21268-2:2020-01 PB/FCH/6/D:10.04.2017","categories":["environment"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen (calculated)","search_en":"Soil, ground Total nitrogen (calculated) PN-EN ISO 21268-2:2020-01 PB/FCH/6/D:10.04.2017","test_object_en":"Soil, ground","search_zh":"土壤、土体 总氮（由计算得出） PN-EN ISO 21268-2:2020-01 PB/FCH/6/D:10.04.2017","test_object_zh":"土壤、土体","methodology_zh":"总氮（由计算得出）"},{"_id":"6a832b7f884ede9a1b2c5545","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 10000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 10000) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 21268-2:2020-01 | PN-ISO 9297:1994","norm_bases":["PN-EN ISO 21268-2:2020-01","PN-ISO 9297:1994"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Stężenie chlorków\nZakres (5,0 – 10000) mg/l\nMetoda miareczkowa PN-EN ISO 21268-2:2020-01 | PN-ISO 9297:1994 Gleba, grunty Stezenie chlorkow\nZakres (5,0 – 10000) mg/l\nMetoda miareczkowa PN-EN ISO 21268-2:2020-01 | PN-ISO 9297:1994","categories":["environment"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 10000) mg/l"}],"search_en":"Soil, ground Chloride concentration Titrimetric method Range PN-EN ISO 21268-2:2020-01 | PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Soil, ground","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 10000) mg/l"}],"search_zh":"土壤、土体 氯化物浓度 滴定法 范围 PN-EN ISO 21268-2:2020-01 | PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c5546","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Stężenie chromu (VI)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chromu (VI)","reference":"PN-EN ISO 21268-2:2020-01","norm_bases":["PN-EN ISO 21268-2:2020-01"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Stężenie chromu (VI) PN-EN ISO 21268-2:2020-01 Gleba, grunty Stezenie chromu (VI) PN-EN ISO 21268-2:2020-01","categories":["environment"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) concentration","search_en":"Soil, ground Chromium(VI) concentration PN-EN ISO 21268-2:2020-01","test_object_en":"Soil, ground","search_zh":"土壤、土体 六价铬浓度 PN-EN ISO 21268-2:2020-01","test_object_zh":"土壤、土体","methodology_zh":"六价铬浓度"},{"_id":"6a832b7f884ede9a1b2c5547","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"","parameters":[{"name":"Zakres","range":"(0,010 – 5,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zakres (0,010 – 5,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 18412:2007 Dokumenty odniesienia","norm_bases":["PN-EN ISO 18412:2007 Dokumenty odniesienia"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Zakres (0,010 – 5,00) mg/l\nMetoda spektrofotometryczna PN-EN ISO 18412:2007 Dokumenty odniesienia Gleba, grunty Zakres (0,010 – 5,00) mg/l\nMetoda spektrofotometryczna PN-EN ISO 18412:2007 Dokumenty odniesienia","categories":["environment"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,010 – 5,00) mg/l"}],"search_en":"Soil, ground Spectrophotometric method Range PN-EN ISO 18412:2007 Dokumenty odniesienia","technique_en":"Spectrophotometric method","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(0,010 – 5,00) mg/l"}],"search_zh":"土壤、土体 分光光度法 范围 PN-EN ISO 18412:2007 Dokumenty odniesienia","technique_zh":"分光光度法","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c5548","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Stężenie chromu (III) (z obliczeń) badane cechy/metoda","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chromu (III) (z obliczeń) badane cechy/metoda","reference":"PN-EN ISO 18412:2007 Dokumenty odniesienia","norm_bases":["PN-EN ISO 18412:2007 Dokumenty odniesienia"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Stężenie chromu (III) (z obliczeń) badane cechy/metoda PN-EN ISO 18412:2007 Dokumenty odniesienia Gleba, grunty Stezenie chromu (III) (z obliczen) badane cechy/metoda PN-EN ISO 18412:2007 Dokumenty odniesienia","categories":["environment"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium (III) concentration (calculated) tested properties/method","search_en":"Soil, ground Chromium (III) concentration (calculated) tested properties/method PN-EN ISO 18412:2007 Dokumenty odniesienia","test_object_en":"Soil, ground","search_zh":"土壤、土体 PN-EN ISO 18412:2007 Dokumenty odniesienia","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c5549","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Stężenie fosforanów","parameters":[{"name":"Zakres","range":"(0,05 – 200) mg/l"}],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie fosforanów\nZakres (0,05 – 200) mg/l","reference":"PN-EN ISO 21268-2:2020-01 | PN-EN ISO 6878:2006 pkt. 4","norm_bases":["PN-EN ISO 21268-2:2020-01","PN-EN ISO 6878:2006 pkt. 4"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Stężenie fosforanów\nZakres (0,05 – 200) mg/l PN-EN ISO 21268-2:2020-01 | PN-EN ISO 6878:2006 pkt. 4 Gleba, grunty Stezenie fosforanow\nZakres (0,05 – 200) mg/l PN-EN ISO 21268-2:2020-01 | PN-EN ISO 6878:2006 pkt. 4","categories":["environment"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphate concentration","parameters_en":[{"name":"Range","range":"(0,05 – 200) mg/l"}],"search_en":"Soil, ground Phosphate concentration Range PN-EN ISO 21268-2:2020-01 | PN-EN ISO 6878:2006 pkt. 4","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(0,05 – 200) mg/l"}],"search_zh":"土壤、土体 磷酸盐浓度 范围 PN-EN ISO 21268-2:2020-01 | PN-EN ISO 6878:2006 pkt. 4","test_object_zh":"土壤、土体","methodology_zh":"磷酸盐浓度"},{"_id":"6a832b7f884ede9a1b2c554a","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"","parameters":[],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Metoda spektrofotometryczna","reference":"+Ap1:2010+Ap2:2010","norm_bases":["+Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Metoda spektrofotometryczna +Ap1:2010+Ap2:2010 Gleba, grunty Metoda spektrofotometryczna +Ap1:2010+Ap2:2010","categories":["environment"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Soil, ground Spectrophotometric method +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Soil, ground","search_zh":"土壤、土体 分光光度法 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c554b","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,016 – 65,0) mg/l"}],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,016 – 65,0) mg/l","reference":"PN-EN ISO 21268-2:2020-01 | PN-EN ISO 6878:2006 pkt 8","norm_bases":["PN-EN ISO 21268-2:2020-01","PN-EN ISO 6878:2006 pkt 8"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Stężenie fosforu ogólnego\nZakres (0,016 – 65,0) mg/l PN-EN ISO 21268-2:2020-01 | PN-EN ISO 6878:2006 pkt 8 Gleba, grunty Stezenie fosforu ogolnego\nZakres (0,016 – 65,0) mg/l PN-EN ISO 21268-2:2020-01 | PN-EN ISO 6878:2006 pkt 8","categories":["environment"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,016 – 65,0) mg/l"}],"search_en":"Soil, ground Total phosphorus concentration Range PN-EN ISO 21268-2:2020-01 | PN-EN ISO 6878:2006 pkt 8","test_object_en":"Soil, ground","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,016 – 65,0) mg/l"}],"search_zh":"土壤、土体 总磷浓度 范围 PN-EN ISO 21268-2:2020-01 | PN-EN ISO 6878:2006 pkt 8","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c554c","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"","parameters":[],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Metoda spektrofotometryczna","reference":"+Ap1:2010+Ap2:2010","norm_bases":["+Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Metoda spektrofotometryczna +Ap1:2010+Ap2:2010 Gleba, grunty Metoda spektrofotometryczna +Ap1:2010+Ap2:2010","categories":["environment"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Soil, ground Spectrophotometric method +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Soil, ground","search_zh":"土壤、土体 分光光度法 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c554d","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Stopień kwasowości według Baumanna Gully’ego","parameters":[{"name":"Zakres","range":"(0,6 – 400) ml/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stopień kwasowości według Baumanna Gully’ego\nZakres (0,6 – 400) ml/kg\nMetoda miareczkowa","reference":"PN-EN 16502:2014-12","norm_bases":["PN-EN 16502:2014-12"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Stopień kwasowości według Baumanna Gully’ego\nZakres (0,6 – 400) ml/kg\nMetoda miareczkowa PN-EN 16502:2014-12 Gleba, grunty Stopien kwasowosci wedlug Baumanna Gully’ego\nZakres (0,6 – 400) ml/kg\nMetoda miareczkowa PN-EN 16502:2014-12","categories":["environment"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Degree of acidity according to Baumann Gully","parameters_en":[{"name":"Range","range":"(0,6 – 400) ml/kg"}],"search_en":"Soil, ground Degree of acidity according to Baumann Gully Titrimetric method Range PN-EN 16502:2014-12","technique_en":"Titrimetric method","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(0,6 – 400) ml/kg"}],"search_zh":"土壤、土体 滴定法 范围 PN-EN 16502:2014-12","technique_zh":"滴定法","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c554e","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Stężenie pierwiastków","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie pierwiastków","reference":"PN-EN ISO 21268-2:2020-01","norm_bases":["PN-EN ISO 21268-2:2020-01"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Stężenie pierwiastków PN-EN ISO 21268-2:2020-01 Gleba, grunty Stezenie pierwiastkow PN-EN ISO 21268-2:2020-01","categories":["environment"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","search_en":"Soil, ground Element concentration PN-EN ISO 21268-2:2020-01","test_object_en":"Soil, ground","methodology_zh":"元素浓度","search_zh":"土壤、土体 元素浓度 PN-EN ISO 21268-2:2020-01","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c554f","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"","parameters":[{"name":"arsen","range":"(0,050 – 100) mg/l"},{"name":"antymon","range":"(0,050 – 100) mg/l"},{"name":"bar","range":"(0,001 – 1000) mg/l"},{"name":"beryl","range":"(0,001 – 100) mg/l"},{"name":"bor","range":"(0,015 – 500) mg/l"},{"name":"chrom","range":"(0,003 – 500) mg/l"},{"name":"cyna","range":"(0,050 – 100) mg/l"},{"name":"cynk","range":"(0,005 – 1000) mg/l"},{"name":"glin","range":"(0,010 – 500) mg/l"},{"name":"kadm","range":"(0,0005 – 500) mg/l"},{"name":"kobalt","range":"(0,002 – 100) mg/l"},{"name":"magnez","range":"(0,007 – 1000) mg/l"},{"name":"mangan","range":"(0,001 – 500) mg/l"},{"name":"miedź","range":"(0,004 – 1000) mg/l"},{"name":"molibden","range":"(0,004 – 100) mg/l"},{"name":"nikiel","range":"(0,004 – 500) mg/l"},{"name":"ołów","range":"(0,010 – 500) mg/l"},{"name":"potas","range":"(1,00 – 1000) mg/l"},{"name":"selen","range":"(0,20 – 100) mg/l"},{"name":"sód","range":"(1,00 – 1000) mg/l"},{"name":"srebro","range":"(0,001 – 100) mg/l"},{"name":"stront","range":"(0,003 – 500) mg/l"},{"name":"tal","range":"(0,050 – 100) mg/l"},{"name":"wanad","range":"(0,005 – 100) mg/l"},{"name":"wapń","range":"(0,010 – 1000) mg/l"},{"name":"żelazo","range":"(0,004 – 1000) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zakres:\narsen (0,050 – 100) mg/l\nantymon (0,050 – 100) mg/l\nbar (0,001 – 1000) mg/l\nberyl (0,001 – 100) mg/l\nbor (0,015 – 500) mg/l\nchrom (0,003 – 500) mg/l\ncyna (0,050 – 100) mg/l\ncynk (0,005 – 1000) mg/l\nglin (0,010 – 500) mg/l\nkadm (0,0005 – 500) mg/l\nkobalt (0,002 – 100) mg/l\nmagnez (0,007 – 1000) mg/l\nmangan (0,001 – 500) mg/l\nmiedź (0,004 – 1000) mg/l\nmolibden (0,004 – 100) mg/l\nnikiel (0,004 – 500) mg/l\nołów (0,010 – 500) mg/l\npotas (1,00 – 1000) mg/l\nselen (0,20 – 100) mg/l\nsód (1,00 – 1000) mg/l\nsrebro (0,001 – 100) mg/l\nstront (0,003 – 500) mg/l\ntal (0,050 – 100) mg/l\nwanad (0,005 – 100) mg/l\nwapń (0,010 – 1000) mg/l\nżelazo (0,004 – 1000) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Zakres:\narsen (0,050 – 100) mg/l\nantymon (0,050 – 100) mg/l\nbar (0,001 – 1000) mg/l\nberyl (0,001 – 100) mg/l\nbor (0,015 – 500) mg/l\nchrom (0,003 – 500) mg/l\ncyna (0,050 – 100) mg/l\ncynk (0,005 – 1000) mg/l\nglin (0,010 – 500) mg/l\nkadm (0,0005 – 500) mg/l\nkobalt (0,002 – 100) mg/l\nmagnez (0,007 – 1000) mg/l\nmangan (0,001 – 500) mg/l\nmiedź (0,004 – 1000) mg/l\nmolibden (0,004 – 100) mg/l\nnikiel (0,004 – 500) mg/l\nołów (0,010 – 500) mg/l\npotas (1,00 – 1000) mg/l\nselen (0,20 – 100) mg/l\nsód (1,00 – 1000) mg/l\nsrebro (0,001 – 100) mg/l\nstront (0,003 – 500) mg/l\ntal (0,050 – 100) mg/l\nwanad (0,005 – 100) mg/l\nwapń (0,010 – 1000) mg/l\nżelazo (0,004 – 1000) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Gleba, grunty Zakres:\narsen (0,050 – 100) mg/l\nantymon (0,050 – 100) mg/l\nbar (0,001 – 1000) mg/l\nberyl (0,001 – 100) mg/l\nbor (0,015 – 500) mg/l\nchrom (0,003 – 500) mg/l\ncyna (0,050 – 100) mg/l\ncynk (0,005 – 1000) mg/l\nglin (0,010 – 500) mg/l\nkadm (0,0005 – 500) mg/l\nkobalt (0,002 – 100) mg/l\nmagnez (0,007 – 1000) mg/l\nmangan (0,001 – 500) mg/l\nmiedz (0,004 – 1000) mg/l\nmolibden (0,004 – 100) mg/l\nnikiel (0,004 – 500) mg/l\nolow (0,010 – 500) mg/l\npotas (1,00 – 1000) mg/l\nselen (0,20 – 100) mg/l\nsod (1,00 – 1000) mg/l\nsrebro (0,001 – 100) mg/l\nstront (0,003 – 500) mg/l\ntal (0,050 – 100) mg/l\nwanad (0,005 – 100) mg/l\nwapn (0,010 – 1000) mg/l\nzelazo (0,004 – 1000) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["materials","environment"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"arsenic","range":"(0,050 – 100) mg/l"},{"name":"antimony","range":"(0,050 – 100) mg/l"},{"name":"barium","range":"(0,001 – 1000) mg/l"},{"name":"beryllium","range":"(0,001 – 100) mg/l"},{"name":"boron","range":"(0,015 – 500) mg/l"},{"name":"chromium","range":"(0,003 – 500) mg/l"},{"name":"tin","range":"(0,050 – 100) mg/l"},{"name":"zinc","range":"(0,005 – 1000) mg/l"},{"name":"aluminium","range":"(0,010 – 500) mg/l"},{"name":"cadmium","range":"(0,0005 – 500) mg/l"},{"name":"cobalt","range":"(0,002 – 100) mg/l"},{"name":"magnesium","range":"(0,007 – 1000) mg/l"},{"name":"manganese","range":"(0,001 – 500) mg/l"},{"name":"copper","range":"(0,004 – 1000) mg/l"},{"name":"molybdenum","range":"(0,004 – 100) mg/l"},{"name":"nickel","range":"(0,004 – 500) mg/l"},{"name":"lead","range":"(0,010 – 500) mg/l"},{"name":"potassium","range":"(1,00 – 1000) mg/l"},{"name":"selenium","range":"(0,20 – 100) mg/l"},{"name":"sodium","range":"(1,00 – 1000) mg/l"},{"name":"silver","range":"(0,001 – 100) mg/l"},{"name":"strontium","range":"(0,003 – 500) mg/l"},{"name":"thallium","range":"(0,050 – 100) mg/l"},{"name":"vanadium","range":"(0,005 – 100) mg/l"},{"name":"calcium","range":"(0,010 – 1000) mg/l"},{"name":"iron","range":"(0,004 – 1000) mg/l"}],"search_en":"Soil, ground Inductively coupled plasma optical emission spectrometry (ICP-OES) arsenic antimony barium beryllium boron chromium tin zinc aluminium cadmium cobalt magnesium manganese copper molybdenum nickel lead potassium selenium sodium silver strontium thallium vanadium calcium iron PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Soil, ground","parameters_zh":[{"name":"砷","range":"(0,050 – 100) mg/l"},{"name":"锑","range":"(0,050 – 100) mg/l"},{"name":"钡","range":"(0,001 – 1000) mg/l"},{"name":"铍","range":"(0,001 – 100) mg/l"},{"name":"硼","range":"(0,015 – 500) mg/l"},{"name":"铬","range":"(0,003 – 500) mg/l"},{"name":"锡","range":"(0,050 – 100) mg/l"},{"name":"锌","range":"(0,005 – 1000) mg/l"},{"name":"铝","range":"(0,010 – 500) mg/l"},{"name":"镉","range":"(0,0005 – 500) mg/l"},{"name":"钴","range":"(0,002 – 100) mg/l"},{"name":"镁","range":"(0,007 – 1000) mg/l"},{"name":"锰","range":"(0,001 – 500) mg/l"},{"name":"铜","range":"(0,004 – 1000) mg/l"},{"name":"钼","range":"(0,004 – 100) mg/l"},{"name":"镍","range":"(0,004 – 500) mg/l"},{"name":"铅","range":"(0,010 – 500) mg/l"},{"name":"钾","range":"(1,00 – 1000) mg/l"},{"name":"硒","range":"(0,20 – 100) mg/l"},{"name":"钠","range":"(1,00 – 1000) mg/l"},{"name":"银","range":"(0,001 – 100) mg/l"},{"name":"锶","range":"(0,003 – 500) mg/l"},{"name":"铊","range":"(0,050 – 100) mg/l"},{"name":"钒","range":"(0,005 – 100) mg/l"},{"name":"钙","range":"(0,010 – 1000) mg/l"},{"name":"铁","range":"(0,004 – 1000) mg/l"}],"search_zh":"土壤、土体 电感耦合等离子体原子发射光谱法（ICP-OES） 砷 锑 钡 铍 硼 铬 锡 锌 铝 镉 钴 镁 锰 铜 钼 镍 铅 钾 硒 钠 银 锶 铊 钒 钙 铁 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c5550","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Stężenie rozpuszczonego węgla","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie rozpuszczonego węgla","reference":"PN-EN 12457-4:2006","norm_bases":["PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Stężenie rozpuszczonego węgla PN-EN 12457-4:2006 Gleba, grunty Stezenie rozpuszczonego wegla PN-EN 12457-4:2006","categories":["environment"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved carbon concentration","search_en":"Soil, ground Dissolved carbon concentration PN-EN 12457-4:2006","test_object_en":"Soil, ground","search_zh":"土壤、土体 PN-EN 12457-4:2006","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c5551","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"organicznego (DOC)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"organicznego (DOC)","reference":"PN-EN ISO 21268-2:2020-01","norm_bases":["PN-EN ISO 21268-2:2020-01"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty organicznego (DOC) PN-EN ISO 21268-2:2020-01 Gleba, grunty organicznego (DOC) PN-EN ISO 21268-2:2020-01","categories":["environment"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"organicznego (DOC)","search_en":"Soil, ground organicznego (DOC) PN-EN ISO 21268-2:2020-01","test_object_en":"Soil, ground","search_zh":"土壤、土体 PN-EN ISO 21268-2:2020-01","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c5552","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"","parameters":[{"name":"Zakres","range":"(1,00 – 2000) mg/l"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Zakres (1,00 – 2000) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Zakres (1,00 – 2000) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999 Gleba, grunty Zakres (1,00 – 2000) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999","categories":["environment"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(1,00 – 2000) mg/l"}],"search_en":"Soil, ground Spectrometry method in the infrared range IR Range PN-EN 1484:1999","technique_en":"Spectrometry method in the infrared range IR","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(1,00 – 2000) mg/l"}],"search_zh":"土壤、土体 红外光谱法 IR 范围 PN-EN 1484:1999","test_object_zh":"土壤、土体","technique_zh":"红外光谱法 IR"},{"_id":"6a832b7f884ede9a1b2c5553","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Stężenie rtęci","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie rtęci","reference":"PN-EN 12457-4:2006","norm_bases":["PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Stężenie rtęci PN-EN 12457-4:2006 Gleba, grunty Stezenie rteci PN-EN 12457-4:2006","categories":["environment"],"row_index":139,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","search_en":"Soil, ground Mercury concentration PN-EN 12457-4:2006","test_object_en":"Soil, ground","methodology_zh":"汞浓度","search_zh":"土壤、土体 汞浓度 PN-EN 12457-4:2006","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c5554","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"","parameters":[{"name":"Zakres","range":"(0,0002 – 5,00) mg/l"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres (0,0002 – 5,00) mg/l","reference":"PN-EN ISO 21268-2:2020-01","norm_bases":["PN-EN ISO 21268-2:2020-01"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Zakres (0,0002 – 5,00) mg/l PN-EN ISO 21268-2:2020-01 Gleba, grunty Zakres (0,0002 – 5,00) mg/l PN-EN ISO 21268-2:2020-01","categories":["environment"],"row_index":140,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,0002 – 5,00) mg/l"}],"search_en":"Soil, ground Range PN-EN ISO 21268-2:2020-01","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(0,0002 – 5,00) mg/l"}],"search_zh":"土壤、土体 范围 PN-EN ISO 21268-2:2020-01","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c5555","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"","parameters":[],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012 +Ap1:2016-07","norm_bases":["PN-EN ISO 12846:2012 +Ap1:2016-07"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 +Ap1:2016-07 Gleba, grunty Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 +Ap1:2016-07","categories":["environment"],"row_index":141,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Soil, ground Cold vapour atomic absorption spectrometry (CVAAS) PN-EN ISO 12846:2012 +Ap1:2016-07","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Soil, ground","search_zh":"土壤、土体 冷蒸气原子吸收光谱法（CVAAS） PN-EN ISO 12846:2012 +Ap1:2016-07","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c5556","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10,0 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN ISO 21268-2:2020-01 | PN-ISO 9280:2002","norm_bases":["PN-EN ISO 21268-2:2020-01","PN-ISO 9280:2002"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Stężenie siarczanów\nZakres (10,0 – 5000) mg/l\nMetoda wagowa PN-EN ISO 21268-2:2020-01 | PN-ISO 9280:2002 Gleba, grunty Stezenie siarczanow\nZakres (10,0 – 5000) mg/l\nMetoda wagowa PN-EN ISO 21268-2:2020-01 | PN-ISO 9280:2002","categories":["environment"],"row_index":142,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10,0 – 5000) mg/l"}],"search_en":"Soil, ground Sulfate concentration Gravimetric method Range PN-EN ISO 21268-2:2020-01 | PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Soil, ground","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10,0 – 5000) mg/l"}],"search_zh":"土壤、土体 硫酸盐浓度 重量法 范围 PN-EN ISO 21268-2:2020-01 | PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c5557","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Stężenie siarkowodoru i siarczków","parameters":[{"name":"Zakres","range":"(0,2 – 10,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie siarkowodoru i siarczków\nZakres (0,2 – 10,0) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 21268-2:2020-01 | PN-74/C-04566/03","norm_bases":["PN-EN ISO 21268-2:2020-01","PN-74/C-04566/03"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Stężenie siarkowodoru i siarczków\nZakres (0,2 – 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 21268-2:2020-01 | PN-74/C-04566/03 Gleba, grunty Stezenie siarkowodoru i siarczkow\nZakres (0,2 – 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 21268-2:2020-01 | PN-74/C-04566/03","categories":["environment"],"row_index":143,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen sulfide and sulfide concentration","parameters_en":[{"name":"Range","range":"(0,2 – 10,0) mg/l"}],"search_en":"Soil, ground Hydrogen sulfide and sulfide concentration Titrimetric method Range PN-EN ISO 21268-2:2020-01 | PN-74/C-04566/03","technique_en":"Titrimetric method","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(0,2 – 10,0) mg/l"}],"search_zh":"土壤、土体 硫化氢与硫化物浓度 滴定法 范围 PN-EN ISO 21268-2:2020-01 | PN-74/C-04566/03","technique_zh":"滴定法","test_object_zh":"土壤、土体","methodology_zh":"硫化氢与硫化物浓度"},{"_id":"6a832b7f884ede9a1b2c5558","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Substancje rozpuszczone ogólne","parameters":[{"name":"Zakres","range":"(10,0 – 50000) mg/l"},{"name":"Zawartość stałych związków rozpuszczonych - TDS (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone ogólne\nZakres:\nZakres (10,0 – 50000) mg/l\nZawartość stałych związków rozpuszczonych - TDS (z obliczeń)\nMetoda wagowa","reference":"PN-EN 12457-4:2006 | PN-EN ISO 21268-2:2020-01 | PN-EN 15216:2010","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 21268-2:2020-01","PN-EN 15216:2010"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Substancje rozpuszczone ogólne\nZakres:\nZakres (10,0 – 50000) mg/l\nZawartość stałych związków rozpuszczonych - TDS (z obliczeń)\nMetoda wagowa PN-EN 12457-4:2006 | PN-EN ISO 21268-2:2020-01 | PN-EN 15216:2010 Gleba, grunty Substancje rozpuszczone ogolne\nZakres:\nZakres (10,0 – 50000) mg/l\nZawartosc stalych zwiazkow rozpuszczonych - TDS (z obliczen)\nMetoda wagowa PN-EN 12457-4:2006 | PN-EN ISO 21268-2:2020-01 | PN-EN 15216:2010","categories":["environment"],"row_index":144,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids","parameters_en":[{"name":"Range","range":"(10,0 – 50000) mg/l"},{"name":"Total dissolved solids content - TDS (calculated)"}],"search_en":"Soil, ground Total dissolved solids Gravimetric method Range Total dissolved solids content - TDS (calculated) PN-EN 12457-4:2006 | PN-EN ISO 21268-2:2020-01 | PN-EN 15216:2010","technique_en":"Gravimetric method","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(10,0 – 50000) mg/l"},{"name":"Zawartość stałych związków rozpuszczonych - TDS (z obliczeń)"}],"search_zh":"土壤、土体 重量法 范围 PN-EN 12457-4:2006 | PN-EN ISO 21268-2:2020-01 | PN-EN 15216:2010","technique_zh":"重量法","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c5559","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Zasadowość ogólna (zdolność do neutralizacji kwasów ANC)","parameters":[{"name":"Zakres","range":"(50 – 50000) mg/kg CaCO3"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zasadowość ogólna (zdolność do neutralizacji kwasów ANC)\nZakres (50 – 50000) mg/kg CaCO3\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN ISO 21268-2:2020-01 | PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 21268-2:2020-01","PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Zasadowość ogólna (zdolność do neutralizacji kwasów ANC)\nZakres (50 – 50000) mg/kg CaCO3\nMetoda miareczkowania potencjometrycznego PN-EN ISO 21268-2:2020-01 | PN-EN ISO 9963-1:2001+Ap1:2004 Gleba, grunty Zasadowosc ogolna (zdolnosc do neutralizacji kwasow ANC)\nZakres (50 – 50000) mg/kg CaCO3\nMetoda miareczkowania potencjometrycznego PN-EN ISO 21268-2:2020-01 | PN-EN ISO 9963-1:2001+Ap1:2004","categories":["environment"],"row_index":145,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total alkalinity (acid neutralisation capacity ANC)","parameters_en":[{"name":"Range","range":"(50 – 50000) mg/kg CaCO3"}],"search_en":"Soil, ground Total alkalinity (acid neutralisation capacity ANC) Potentiometric titration method Range PN-EN ISO 21268-2:2020-01 | PN-EN ISO 9963-1:2001+Ap1:2004","technique_en":"Potentiometric titration method","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(50 – 50000) mg/kg CaCO3"}],"search_zh":"土壤、土体 总碱度（酸中和能力 ANC） 电位滴定法 范围 PN-EN ISO 21268-2:2020-01 | PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"电位滴定法","test_object_zh":"土壤、土体","methodology_zh":"总碱度（酸中和能力 ANC）"},{"_id":"6a832b7f884ede9a1b2c555a","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Sucha masa / zawartość wody","parameters":[{"name":"Zakres","range":"(0,10 – 99,5) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Sucha masa / zawartość wody\nZakres (0,10 – 99,5) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN 15934:2013-02 Metoda A","norm_bases":["PN-EN 15934:2013-02 Metoda A"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Sucha masa / zawartość wody\nZakres (0,10 – 99,5) %\nMetoda termograwimetryczna (TGA) PN-EN 15934:2013-02 Metoda A Gleba, grunty Sucha masa / zawartosc wody\nZakres (0,10 – 99,5) %\nMetoda termograwimetryczna (TGA) PN-EN 15934:2013-02 Metoda A","categories":["water","environment"],"row_index":146,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter / water content","parameters_en":[{"name":"Range","range":"(0,10 – 99,5) %"}],"search_en":"Soil, ground Dry matter / water content Thermogravimetric method (TGA) Range PN-EN 15934:2013-02 Metoda A","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(0,10 – 99,5) %"}],"search_zh":"土壤、土体 干物质 / 水分含量 热重法（TGA） 范围 PN-EN 15934:2013-02 Metoda A","technique_zh":"热重法（TGA）","test_object_zh":"土壤、土体","methodology_zh":"干物质 / 水分含量"},{"_id":"6a832b7f884ede9a1b2c555b","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 13,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 13,0\nMetoda potencjometryczna","reference":"ISO 10390:2005 | PN-EN ISO 10390:2022-09 | DIN 38404-5 (07.09)","norm_bases":["ISO 10390:2005","PN-EN ISO 10390:2022-09","DIN 38404-5 (07.09)"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba pH\nZakres 2,0 – 13,0\nMetoda potencjometryczna ISO 10390:2005 | PN-EN ISO 10390:2022-09 | DIN 38404-5 (07.09) Gleba pH\nZakres 2,0 – 13,0\nMetoda potencjometryczna ISO 10390:2005 | PN-EN ISO 10390:2022-09 | DIN 38404-5 (07.09)","categories":["environment"],"row_index":147,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 13,0"}],"search_en":"Soil pH Potentiometric method Range ISO 10390:2005 | PN-EN ISO 10390:2022-09 | DIN 38404-5 (07.09)","technique_en":"Potentiometric method","test_object_en":"Soil","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 13,0"}],"search_zh":"土壤 pH 值 电位法 范围 ISO 10390:2005 | PN-EN ISO 10390:2022-09 | DIN 38404-5 (07.09)","technique_zh":"电位法","test_object_zh":"土壤"},{"_id":"6a832b7f884ede9a1b2c555c","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10,0 – 1300) μS/cm"},{"name":"Zakres","range":"(1,0 – 130) mS/m"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres:\nZakres (10,0 – 1300) μS/cm\nZakres (1,0 – 130) mS/m\nMetoda konduktometryczna","reference":"PN-ISO 11265+AC1:1997","norm_bases":["PN-ISO 11265+AC1:1997"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Przewodność elektryczna właściwa\nZakres:\nZakres (10,0 – 1300) μS/cm\nZakres (1,0 – 130) mS/m\nMetoda konduktometryczna PN-ISO 11265+AC1:1997 Gleba Przewodnosc elektryczna wlasciwa\nZakres:\nZakres (10,0 – 1300) μS/cm\nZakres (1,0 – 130) mS/m\nMetoda konduktometryczna PN-ISO 11265+AC1:1997","categories":["environment"],"row_index":148,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10,0 – 1300) μS/cm"},{"name":"Range","range":"(1,0 – 130) mS/m"}],"search_en":"Soil Electrical conductivity Conductometric method Range Range PN-ISO 11265+AC1:1997","technique_en":"Conductometric method","test_object_en":"Soil","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10,0 – 1300) μS/cm"},{"name":"范围","range":"(1,0 – 130) mS/m"}],"search_zh":"土壤 电导率 电导法 范围 范围 PN-ISO 11265+AC1:1997","technique_zh":"电导法","test_object_zh":"土壤"},{"_id":"6a832b7f884ede9a1b2c555d","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Skład granulometryczny w zakresie wielkości cząstek (0,063 – 20,0) mm z podziałem na frakcje","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"technique":"Metoda sitowa","techniques":["Metoda sitowa"],"computed":[],"activity":"Skład granulometryczny w zakresie wielkości cząstek (0,063 – 20,0) mm z podziałem na frakcje\nZakres (0,5 – 99,5) %\nMetoda sitowa","reference":"PN-R-04032:1998 pkt. 3.3","norm_bases":["PN-R-04032:1998 pkt. 3.3"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Skład granulometryczny w zakresie wielkości cząstek (0,063 – 20,0) mm z podziałem na frakcje\nZakres (0,5 – 99,5) %\nMetoda sitowa PN-R-04032:1998 pkt. 3.3 Gleba Sklad granulometryczny w zakresie wielkosci czastek (0,063 – 20,0) mm z podzialem na frakcje\nZakres (0,5 – 99,5) %\nMetoda sitowa PN-R-04032:1998 pkt. 3.3","categories":["environment"],"row_index":149,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Particle size distribution in the particle size range (0,063 – 20,0) mm divided into fractions","parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"search_en":"Soil Particle size distribution in the particle size range (0,063 – 20,0) mm divided into fractions Sieve method Range PN-R-04032:1998 pkt. 3.3","technique_en":"Sieve method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"土壤 筛析法 范围 PN-R-04032:1998 pkt. 3.3","test_object_zh":"土壤","technique_zh":"筛析法"},{"_id":"6a832b7f884ede9a1b2c555e","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Skład granulometryczny w zakresie wielkości cząstek (0,002 – 2,00) mm z podziałem na frakcje","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"technique":"Metoda areometryczna","techniques":["Metoda areometryczna"],"computed":[],"activity":"Skład granulometryczny w zakresie wielkości cząstek (0,002 – 2,00) mm z podziałem na frakcje\nZakres (0,5 – 99,5) %\nMetoda areometryczna","reference":"PN-R-04032:1998 pkt. 3.1","norm_bases":["PN-R-04032:1998 pkt. 3.1"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Skład granulometryczny w zakresie wielkości cząstek (0,002 – 2,00) mm z podziałem na frakcje\nZakres (0,5 – 99,5) %\nMetoda areometryczna PN-R-04032:1998 pkt. 3.1 Gleba Sklad granulometryczny w zakresie wielkosci czastek (0,002 – 2,00) mm z podzialem na frakcje\nZakres (0,5 – 99,5) %\nMetoda areometryczna PN-R-04032:1998 pkt. 3.1","categories":["environment"],"row_index":150,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Particle size distribution in the particle size range (0,002 – 2,00) mm divided into fractions","parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"search_en":"Soil Particle size distribution in the particle size range (0,002 – 2,00) mm divided into fractions Hydrometer method Range PN-R-04032:1998 pkt. 3.1","technique_en":"Hydrometer method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"土壤 比重计法 范围 PN-R-04032:1998 pkt. 3.1","test_object_zh":"土壤","technique_zh":"比重计法"},{"_id":"6a832b7f884ede9a1b2c555f","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Stężenie i zawartość cyjanków wolnych i ogólnych","parameters":[{"name":"Zakres","range":"(0,0050 – 10) mg/l"},{"name":"Zakres","range":"(0,050 – 100) mg/kg"},{"name":"Stężenie cyjanków związanych (z obliczeń)"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie i zawartość cyjanków wolnych i ogólnych\nZakres:\nZakres (0,0050 – 10) mg/l\nZakres (0,050 – 100) mg/kg\nStężenie cyjanków związanych (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN 12457-4:2006 | PN-EN ISO 14403-2:2012","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 14403-2:2012"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Stężenie i zawartość cyjanków wolnych i ogólnych\nZakres:\nZakres (0,0050 – 10) mg/l\nZakres (0,050 – 100) mg/kg\nStężenie cyjanków związanych (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN 12457-4:2006 | PN-EN ISO 14403-2:2012 Gleba Stezenie i zawartosc cyjankow wolnych i ogolnych\nZakres:\nZakres (0,0050 – 10) mg/l\nZakres (0,050 – 100) mg/kg\nStezenie cyjankow zwiazanych (z obliczen)\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN 12457-4:2006 | PN-EN ISO 14403-2:2012","categories":["environment"],"row_index":151,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration and content of free and total cyanides","parameters_en":[{"name":"Range","range":"(0,0050 – 10) mg/l"},{"name":"Range","range":"(0,050 – 100) mg/kg"},{"name":"Combined cyanide concentration (calculated)"}],"search_en":"Soil Concentration and content of free and total cyanides Continuous flow analysis (CFA) with spectrophotometric detection Range Range Combined cyanide concentration (calculated) PN-EN 12457-4:2006 | PN-EN ISO 14403-2:2012","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,0050 – 10) mg/l"},{"name":"范围","range":"(0,050 – 100) mg/kg"},{"name":"络合氰化物浓度（由计算得出）"}],"search_zh":"土壤 连续流动分析（CFA）分光光度检测法 范围 范围 络合氰化物浓度（由计算得出） PN-EN 12457-4:2006 | PN-EN ISO 14403-2:2012","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"土壤"},{"_id":"6a832b7f884ede9a1b2c5560","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Straty przy prażeniu (LOI) / substancje organiczne","parameters":[{"name":"Zakres","range":"(0,1 - 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu (LOI) / substancje organiczne\nZakres (0,1 - 99,5) %\nMetoda wagowa","reference":"PN-EN 15169:2011 | PN-EN 15935:2022-01","norm_bases":["PN-EN 15169:2011","PN-EN 15935:2022-01"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Straty przy prażeniu (LOI) / substancje organiczne\nZakres (0,1 - 99,5) %\nMetoda wagowa PN-EN 15169:2011 | PN-EN 15935:2022-01 Gleba Straty przy prazeniu (LOI) / substancje organiczne\nZakres (0,1 - 99,5) %\nMetoda wagowa PN-EN 15169:2011 | PN-EN 15935:2022-01","categories":["environment"],"row_index":152,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition (LOI) / organic matter","parameters_en":[{"name":"Range","range":"(0,1 - 99,5) %"}],"search_en":"Soil Loss on ignition (LOI) / organic matter Gravimetric method Range PN-EN 15169:2011 | PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,1 - 99,5) %"}],"search_zh":"土壤 烧失量（LOI）/ 有机物质 重量法 范围 PN-EN 15169:2011 | PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"土壤","methodology_zh":"烧失量（LOI）/ 有机物质"},{"_id":"6a832b7f884ede9a1b2c5561","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,01 – 2,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (0,01 – 2,00) %\nMetoda miareczkowa","reference":"PN-75/C-04576/15","norm_bases":["PN-75/C-04576/15"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość azotu amonowego\nZakres (0,01 – 2,00) %\nMetoda miareczkowa PN-75/C-04576/15 Gleba Zawartosc azotu amonowego\nZakres (0,01 – 2,00) %\nMetoda miareczkowa PN-75/C-04576/15","categories":["environment"],"row_index":153,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,01 – 2,00) %"}],"search_en":"Soil Ammonium nitrogen content Titrimetric method Range PN-75/C-04576/15","technique_en":"Titrimetric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,01 – 2,00) %"}],"search_zh":"土壤 氨氮含量 滴定法 范围 PN-75/C-04576/15","technique_zh":"滴定法","test_object_zh":"土壤","methodology_zh":"氨氮含量"},{"_id":"6a832b7f884ede9a1b2c5562","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(2,0 – 500) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (2,0 – 500) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-R-04028:1997 | PN-EN ISO 11732:2007","norm_bases":["PN-R-04028:1997","PN-EN ISO 11732:2007"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość azotu amonowego\nZakres (2,0 – 500) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-R-04028:1997 | PN-EN ISO 11732:2007 Gleba Zawartosc azotu amonowego\nZakres (2,0 – 500) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-R-04028:1997 | PN-EN ISO 11732:2007","categories":["environment"],"row_index":154,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(2,0 – 500) mg/kg"}],"search_en":"Soil Ammonium nitrogen content Continuous flow analysis (CFA) with spectrophotometric detection Range PN-R-04028:1997 | PN-EN ISO 11732:2007","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(2,0 – 500) mg/kg"}],"search_zh":"土壤 氨氮含量 连续流动分析（CFA）分光光度检测法 范围 PN-R-04028:1997 | PN-EN ISO 11732:2007","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"土壤","methodology_zh":"氨氮含量"},{"_id":"6a832b7f884ede9a1b2c5563","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość azotu azotanowego","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość azotu azotanowego\nZakres (2,0 – 1000) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-R-04028:1997 | PN-EN ISO 13395:2001","norm_bases":["PN-R-04028:1997","PN-EN ISO 13395:2001"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość azotu azotanowego\nZakres (2,0 – 1000) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-R-04028:1997 | PN-EN ISO 13395:2001 Gleba Zawartosc azotu azotanowego\nZakres (2,0 – 1000) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-R-04028:1997 | PN-EN ISO 13395:2001","categories":["environment"],"row_index":155,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen content","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/kg"}],"search_en":"Soil Nitrate nitrogen content Continuous flow analysis (CFA) with spectrophotometric detection Range PN-R-04028:1997 | PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/kg"}],"search_zh":"土壤 硝酸盐氮含量 连续流动分析（CFA）分光光度检测法 范围 PN-R-04028:1997 | PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"土壤","methodology_zh":"硝酸盐氮含量"},{"_id":"6a832b7f884ede9a1b2c5564","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,002 – 8,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres (0,002 – 8,00) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość azotu Kjeldahla\nZakres (0,002 – 8,00) %\nMetoda miareczkowa PN-EN 13342:2002 Gleba Zawartosc azotu Kjeldahla\nZakres (0,002 – 8,00) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["environment"],"row_index":156,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,002 – 8,00) %"}],"search_en":"Soil Kjeldahl nitrogen content Titrimetric method Range PN-EN 13342:2002","technique_en":"Titrimetric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,002 – 8,00) %"}],"search_zh":"土壤 凯氏氮含量 滴定法 范围 PN-EN 13342:2002","technique_zh":"滴定法","test_object_zh":"土壤","methodology_zh":"凯氏氮含量"},{"_id":"6a832b7f884ede9a1b2c5565","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość azotu mineralnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość azotu mineralnego (z obliczeń)","reference":"PN-R-04028:1997","norm_bases":["PN-R-04028:1997"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość azotu mineralnego (z obliczeń) PN-R-04028:1997 Gleba Zawartosc azotu mineralnego (z obliczen) PN-R-04028:1997","categories":["environment"],"row_index":157,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral nitrogen content (calculated)","search_en":"Soil Mineral nitrogen content (calculated) PN-R-04028:1997","test_object_en":"Soil","search_zh":"土壤 矿质氮含量（由计算得出） PN-R-04028:1997","test_object_zh":"土壤","methodology_zh":"矿质氮含量（由计算得出）"},{"_id":"6a832b7f884ede9a1b2c5566","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość azotu organicznego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość azotu organicznego (z obliczeń)","reference":"PB/FCH/15/D:10.04.2017","norm_bases":["PB/FCH/15/D:10.04.2017"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość azotu organicznego (z obliczeń) PB/FCH/15/D:10.04.2017 Gleba Zawartosc azotu organicznego (z obliczen) PB/FCH/15/D:10.04.2017","categories":["environment"],"row_index":158,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Organic nitrogen content (calculated)","search_en":"Soil Organic nitrogen content (calculated) PB/FCH/15/D:10.04.2017","test_object_en":"Soil","search_zh":"土壤 PB/FCH/15/D:10.04.2017","test_object_zh":"土壤"},{"_id":"6a832b7f884ede9a1b2c5567","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość benzyny (C6-C12)","parameters":[{"name":"Zakres","range":"(1,0 – 750) mg/kg"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Zawartość benzyny (C6-C12)\nZakres (1,0 – 750) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PN-ISO 14507:2007 PB/I/3/G:10.04.2017","norm_bases":["PN-ISO 14507:2007 PB/I/3/G:10.04.2017"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość benzyny (C6-C12)\nZakres (1,0 – 750) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej detekcją płomieniowo-jonizacyjną (HS-GC-FID) PN-ISO 14507:2007 PB/I/3/G:10.04.2017 Gleba Zawartosc benzyny (C6-C12)\nZakres (1,0 – 750) mg/kg\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej detekcja plomieniowo-jonizacyjna (HS-GC-FID) PN-ISO 14507:2007 PB/I/3/G:10.04.2017","categories":["environment"],"row_index":159,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Petrol content (C6-C12)","parameters_en":[{"name":"Range","range":"(1,0 – 750) mg/kg"}],"search_en":"Soil Petrol content (C6-C12) Headspace gas chromatography with flame ionization detection (HS-GC-FID) Range PN-ISO 14507:2007 PB/I/3/G:10.04.2017","technique_en":"Headspace gas chromatography with flame ionization detection (HS-GC-FID)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(1,0 – 750) mg/kg"}],"search_zh":"土壤 汽油（C6-C12）含量 范围 PN-ISO 14507:2007 PB/I/3/G:10.04.2017","test_object_zh":"土壤","methodology_zh":"汽油（C6-C12）含量"},{"_id":"6a832b7f884ede9a1b2c5568","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość chlorków","parameters":[{"name":"Zakres","range":"(50 – 12000) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość chlorków\nZakres (50 – 12000) mg/kg\nMetoda miareczkowa","reference":"PB/FCH/10/E:10.04.2017","norm_bases":["PB/FCH/10/E:10.04.2017"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość chlorków\nZakres (50 – 12000) mg/kg\nMetoda miareczkowa PB/FCH/10/E:10.04.2017 Gleba Zawartosc chlorkow\nZakres (50 – 12000) mg/kg\nMetoda miareczkowa PB/FCH/10/E:10.04.2017","categories":["environment"],"row_index":160,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride content","parameters_en":[{"name":"Range","range":"(50 – 12000) mg/kg"}],"search_en":"Soil Chloride content Titrimetric method Range PB/FCH/10/E:10.04.2017","technique_en":"Titrimetric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(50 – 12000) mg/kg"}],"search_zh":"土壤 氯化物含量 滴定法 范围 PB/FCH/10/E:10.04.2017","technique_zh":"滴定法","test_object_zh":"土壤","methodology_zh":"氯化物含量"},{"_id":"6a832b7f884ede9a1b2c5569","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość cyjanków wolnych i ogólnych","parameters":[{"name":"Zakres","range":"(0,50 – 100) mg/kg"},{"name":"Zawartość cyjanków związanych (z obliczeń)"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość cyjanków wolnych i ogólnych\nZakres:\nZakres (0,50 – 100) mg/kg\nZawartość cyjanków związanych (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 17380:2013-08","norm_bases":["PN-EN ISO 17380:2013-08"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość cyjanków wolnych i ogólnych\nZakres:\nZakres (0,50 – 100) mg/kg\nZawartość cyjanków związanych (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 17380:2013-08 Gleba Zawartosc cyjankow wolnych i ogolnych\nZakres:\nZakres (0,50 – 100) mg/kg\nZawartosc cyjankow zwiazanych (z obliczen)\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 17380:2013-08","categories":["environment"],"row_index":161,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free and total cyanide content","parameters_en":[{"name":"Range","range":"(0,50 – 100) mg/kg"},{"name":"Combined cyanide content (calculated)"}],"search_en":"Soil Free and total cyanide content Continuous flow analysis (CFA) with spectrophotometric detection Range Combined cyanide content (calculated) PN-EN ISO 17380:2013-08","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,50 – 100) mg/kg"},{"name":"络合氰化物含量（由计算得出）"}],"search_zh":"土壤 游离氰化物与总氰化物含量 连续流动分析（CFA）分光光度检测法 范围 络合氰化物含量（由计算得出） PN-EN ISO 17380:2013-08","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"土壤","methodology_zh":"游离氰化物与总氰化物含量"},{"_id":"6a832b7f884ede9a1b2c556a","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość fenoli","parameters":[{"name":"Zakres","range":"(0,05 – 500) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fenoli\nZakres (0,05 – 500) mg/kg\nMetoda spektrofotometryczna","reference":"PB/FCH/33/D:10.04.2017","norm_bases":["PB/FCH/33/D:10.04.2017"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość fenoli\nZakres (0,05 – 500) mg/kg\nMetoda spektrofotometryczna PB/FCH/33/D:10.04.2017 Gleba Zawartosc fenoli\nZakres (0,05 – 500) mg/kg\nMetoda spektrofotometryczna PB/FCH/33/D:10.04.2017","categories":["environment"],"row_index":162,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol content","parameters_en":[{"name":"Range","range":"(0,05 – 500) mg/kg"}],"search_en":"Soil Phenol content Spectrophotometric method Range PB/FCH/33/D:10.04.2017","technique_en":"Spectrophotometric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,05 – 500) mg/kg"}],"search_zh":"土壤 酚类含量 分光光度法 范围 PB/FCH/33/D:10.04.2017","technique_zh":"分光光度法","test_object_zh":"土壤","methodology_zh":"酚类含量"},{"_id":"6a832b7f884ede9a1b2c556b","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość lotnych węglowodorów aromatycznych (BTX)","parameters":[{"name":"benzen","range":"(0,020 – 15) mg/kg"},{"name":"etylobenzen","range":"(0,020 – 15) mg/kg"},{"name":"toluen","range":"(0,020 – 15) mg/kg"},{"name":"suma ksylenów","range":"(0,020 – 45) mg/kg"},{"name":"styren","range":"(0,050 – 15) mg/kg"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Zawartość lotnych węglowodorów aromatycznych (BTX)\nZakres:\nbenzen (0,020 – 15) mg/kg\netylobenzen (0,020 – 15) mg/kg\ntoluen (0,020 – 15) mg/kg\nsuma ksylenów (0,020 – 45) mg/kg\nstyren (0,050 – 15) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PN-ISO 22155:2016-07","norm_bases":["PN-ISO 22155:2016-07"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość lotnych węglowodorów aromatycznych (BTX)\nZakres:\nbenzen (0,020 – 15) mg/kg\netylobenzen (0,020 – 15) mg/kg\ntoluen (0,020 – 15) mg/kg\nsuma ksylenów (0,020 – 45) mg/kg\nstyren (0,050 – 15) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej detekcją płomieniowo-jonizacyjną (HS-GC-FID) PN-ISO 22155:2016-07 Gleba Zawartosc lotnych weglowodorow aromatycznych (BTX)\nZakres:\nbenzen (0,020 – 15) mg/kg\netylobenzen (0,020 – 15) mg/kg\ntoluen (0,020 – 15) mg/kg\nsuma ksylenow (0,020 – 45) mg/kg\nstyren (0,050 – 15) mg/kg\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej detekcja plomieniowo-jonizacyjna (HS-GC-FID) PN-ISO 22155:2016-07","categories":["environment"],"row_index":163,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of volatile aromatic hydrocarbons (BTX)","parameters_en":[{"name":"benzene","range":"(0,020 – 15) mg/kg"},{"name":"ethylbenzene","range":"(0,020 – 15) mg/kg"},{"name":"toluene","range":"(0,020 – 15) mg/kg"},{"name":"sum of xylenes","range":"(0,020 – 45) mg/kg"},{"name":"styrene","range":"(0,050 – 15) mg/kg"}],"search_en":"Soil Content of volatile aromatic hydrocarbons (BTX) Headspace gas chromatography with flame ionization detection (HS-GC-FID) benzene ethylbenzene toluene sum of xylenes styrene PN-ISO 22155:2016-07","technique_en":"Headspace gas chromatography with flame ionization detection (HS-GC-FID)","test_object_en":"Soil","search_zh":"土壤 苯 乙苯 甲苯 二甲苯总量 苯乙烯 PN-ISO 22155:2016-07","test_object_zh":"土壤","parameters_zh":[{"name":"苯","range":"(0,020 – 15) mg/kg"},{"name":"乙苯","range":"(0,020 – 15) mg/kg"},{"name":"甲苯","range":"(0,020 – 15) mg/kg"},{"name":"二甲苯总量","range":"(0,020 – 45) mg/kg"},{"name":"苯乙烯","range":"(0,050 – 15) mg/kg"}]},{"_id":"6a832b7f884ede9a1b2c556c","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Suma BTX (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma BTX (z obliczeń)","reference":"PN-ISO 22155:2016-07","norm_bases":["PN-ISO 22155:2016-07"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Suma BTX (z obliczeń) PN-ISO 22155:2016-07 Gleba Suma BTX (z obliczen) PN-ISO 22155:2016-07","categories":["environment"],"row_index":164,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of BTX (calculated)","search_en":"Soil Sum of BTX (calculated) PN-ISO 22155:2016-07","test_object_en":"Soil","search_zh":"土壤 BTX 总量（由计算得出） PN-ISO 22155:2016-07","test_object_zh":"土壤","methodology_zh":"BTX 总量（由计算得出）"},{"_id":"6a832b7f884ede9a1b2c556d","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość ogólnego węgla organicznego (TOC)","parameters":[{"name":"Zakres","range":"(0,50 – 60) %"},{"name":"Zakres","range":"(5000 – 600000) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość ogólnego węgla organicznego (TOC)\nZakres:\nZakres (0,50 – 60) %\nZakres (5000 – 600000) mg/kg\nMetoda miareczkowa","reference":"PB/FCH/17/C:10.04.2017","norm_bases":["PB/FCH/17/C:10.04.2017"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość ogólnego węgla organicznego (TOC)\nZakres:\nZakres (0,50 – 60) %\nZakres (5000 – 600000) mg/kg\nMetoda miareczkowa PB/FCH/17/C:10.04.2017 Gleba Zawartosc ogolnego wegla organicznego (TOC)\nZakres:\nZakres (0,50 – 60) %\nZakres (5000 – 600000) mg/kg\nMetoda miareczkowa PB/FCH/17/C:10.04.2017","categories":["environment"],"row_index":165,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon (TOC) content","parameters_en":[{"name":"Range","range":"(0,50 – 60) %"},{"name":"Range","range":"(5000 – 600000) mg/kg"}],"search_en":"Soil Total organic carbon (TOC) content Titrimetric method Range Range PB/FCH/17/C:10.04.2017","technique_en":"Titrimetric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,50 – 60) %"},{"name":"范围","range":"(5000 – 600000) mg/kg"}],"search_zh":"土壤 总有机碳（TOC）含量 滴定法 范围 范围 PB/FCH/17/C:10.04.2017","technique_zh":"滴定法","test_object_zh":"土壤","methodology_zh":"总有机碳（TOC）含量"},{"_id":"6a832b7f884ede9a1b2c556e","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość pierwiastków","parameters":[{"name":"antymon","range":"(2,0 – 500) mg/kg"},{"name":"arsen","range":"(0,50 – 100) mg/kg"},{"name":"bar","range":"(1,0 – 5000) mg/kg"},{"name":"beryl","range":"(2,0 – 100) mg/kg"},{"name":"bor","range":"(50 – 1000) mg/kg"},{"name":"chrom","range":"(1,0 – 500) mg/kg"},{"name":"cyna","range":"(1,0 – 100) mg/kg"},{"name":"cynk","range":"(5,0 – 5000) mg/kg"},{"name":"fosfor","range":"(20 – 1000) mg/kg"},{"name":"glin","range":"(20 – 1000) mg/kg"},{"name":"kadm","range":"(0,20 – 100) mg/kg"},{"name":"kobalt","range":"(1,0 – 1000) mg/kg"},{"name":"krzem","range":"(1000 – 5000) mg/kg"},{"name":"lit","range":"(10 – 500) mg/kg"},{"name":"magnez","range":"(100 – 500000) mg/kg"},{"name":"mangan","range":"(10 – 1000) mg/kg"},{"name":"miedź","range":"(1,0 – 5000) mg/kg"},{"name":"molibden","range":"(1,0 – 1000) mg/kg"},{"name":"nikiel","range":"(1,0 – 5000) mg/kg"},{"name":"ołów","range":"(1,0 – 5000) mg/kg"},{"name":"potas","range":"(100 – 50000) mg/kg"},{"name":"rtęć","range":"(0,10 – 100) mg/kg"},{"name":"selen","range":"(2,0 – 500) mg/kg"},{"name":"srebro","range":"(2,0 – 500) mg/kg"},{"name":"stront","range":"(10 – 1000) mg/kg"},{"name":"sód","range":"(200 – 50000) mg/kg"},{"name":"tal","range":"(0,20 – 500) mg/kg"},{"name":"tytan","range":"(2,0 – 500) mg/kg"},{"name":"uran","range":"(2,0 – 500) mg/kg"},{"name":"wanad","range":"(2,0 – 500) mg/kg"},{"name":"wapń","range":"(200 – 500000) mg/kg"},{"name":"żelazo","range":"(20 – 50000) mg/kg"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nantymon (2,0 – 500) mg/kg\narsen (0,50 – 100) mg/kg\nbar (1,0 – 5000) mg/kg\nberyl (2,0 – 100) mg/kg\nbor (50 – 1000) mg/kg\nchrom (1,0 – 500) mg/kg\ncyna (1,0 – 100) mg/kg\ncynk (5,0 – 5000) mg/kg\nfosfor (20 – 1000) mg/kg\nglin (20 – 1000) mg/kg\nkadm (0,20 – 100) mg/kg\nkobalt (1,0 – 1000) mg/kg\nkrzem (1000 – 5000) mg/kg\nlit (10 – 500) mg/kg\nmagnez (100 – 500000) mg/kg\nmangan (10 – 1000) mg/kg\nmiedź (1,0 – 5000) mg/kg\nmolibden (1,0 – 1000) mg/kg\nnikiel (1,0 – 5000) mg/kg\nołów (1,0 – 5000) mg/kg\npotas (100 – 50000) mg/kg\nrtęć (0,10 – 100) mg/kg\nselen (2,0 – 500) mg/kg\nsrebro (2,0 – 500) mg/kg\nstront (10 – 1000) mg/kg\nsód (200 – 50000) mg/kg\ntal (0,20 – 500) mg/kg\ntytan (2,0 – 500) mg/kg\nuran (2,0 – 500) mg/kg\nwanad (2,0 – 500) mg/kg\nwapń (200 – 500000) mg/kg\nżelazo (20 – 50000) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN 16171:2017-02 | PN-ISO 11466:2002 | PN-EN ISO 17294-2:2024-04 | PN-EN 13657:2006","norm_bases":["PN-EN 16171:2017-02","PN-ISO 11466:2002","PN-EN ISO 17294-2:2024-04","PN-EN 13657:2006"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość pierwiastków\nZakres:\nantymon (2,0 – 500) mg/kg\narsen (0,50 – 100) mg/kg\nbar (1,0 – 5000) mg/kg\nberyl (2,0 – 100) mg/kg\nbor (50 – 1000) mg/kg\nchrom (1,0 – 500) mg/kg\ncyna (1,0 – 100) mg/kg\ncynk (5,0 – 5000) mg/kg\nfosfor (20 – 1000) mg/kg\nglin (20 – 1000) mg/kg\nkadm (0,20 – 100) mg/kg\nkobalt (1,0 – 1000) mg/kg\nkrzem (1000 – 5000) mg/kg\nlit (10 – 500) mg/kg\nmagnez (100 – 500000) mg/kg\nmangan (10 – 1000) mg/kg\nmiedź (1,0 – 5000) mg/kg\nmolibden (1,0 – 1000) mg/kg\nnikiel (1,0 – 5000) mg/kg\nołów (1,0 – 5000) mg/kg\npotas (100 – 50000) mg/kg\nrtęć (0,10 – 100) mg/kg\nselen (2,0 – 500) mg/kg\nsrebro (2,0 – 500) mg/kg\nstront (10 – 1000) mg/kg\nsód (200 – 50000) mg/kg\ntal (0,20 – 500) mg/kg\ntytan (2,0 – 500) mg/kg\nuran (2,0 – 500) mg/kg\nwanad (2,0 – 500) mg/kg\nwapń (200 – 500000) mg/kg\nżelazo (20 – 50000) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN 16171:2017-02 | PN-ISO 11466:2002 | PN-EN ISO 17294-2:2024-04 | PN-EN 13657:2006 Gleba Zawartosc pierwiastkow\nZakres:\nantymon (2,0 – 500) mg/kg\narsen (0,50 – 100) mg/kg\nbar (1,0 – 5000) mg/kg\nberyl (2,0 – 100) mg/kg\nbor (50 – 1000) mg/kg\nchrom (1,0 – 500) mg/kg\ncyna (1,0 – 100) mg/kg\ncynk (5,0 – 5000) mg/kg\nfosfor (20 – 1000) mg/kg\nglin (20 – 1000) mg/kg\nkadm (0,20 – 100) mg/kg\nkobalt (1,0 – 1000) mg/kg\nkrzem (1000 – 5000) mg/kg\nlit (10 – 500) mg/kg\nmagnez (100 – 500000) mg/kg\nmangan (10 – 1000) mg/kg\nmiedz (1,0 – 5000) mg/kg\nmolibden (1,0 – 1000) mg/kg\nnikiel (1,0 – 5000) mg/kg\nolow (1,0 – 5000) mg/kg\npotas (100 – 50000) mg/kg\nrtec (0,10 – 100) mg/kg\nselen (2,0 – 500) mg/kg\nsrebro (2,0 – 500) mg/kg\nstront (10 – 1000) mg/kg\nsod (200 – 50000) mg/kg\ntal (0,20 – 500) mg/kg\ntytan (2,0 – 500) mg/kg\nuran (2,0 – 500) mg/kg\nwanad (2,0 – 500) mg/kg\nwapn (200 – 500000) mg/kg\nzelazo (20 – 50000) mg/kg\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN 16171:2017-02 | PN-ISO 11466:2002 | PN-EN ISO 17294-2:2024-04 | PN-EN 13657:2006","categories":["materials","environment"],"row_index":166,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","parameters_en":[{"name":"antimony","range":"(2,0 – 500) mg/kg"},{"name":"arsenic","range":"(0,50 – 100) mg/kg"},{"name":"barium","range":"(1,0 – 5000) mg/kg"},{"name":"beryllium","range":"(2,0 – 100) mg/kg"},{"name":"boron","range":"(50 – 1000) mg/kg"},{"name":"chromium","range":"(1,0 – 500) mg/kg"},{"name":"tin","range":"(1,0 – 100) mg/kg"},{"name":"zinc","range":"(5,0 – 5000) mg/kg"},{"name":"phosphorus","range":"(20 – 1000) mg/kg"},{"name":"aluminium","range":"(20 – 1000) mg/kg"},{"name":"cadmium","range":"(0,20 – 100) mg/kg"},{"name":"cobalt","range":"(1,0 – 1000) mg/kg"},{"name":"silicon","range":"(1000 – 5000) mg/kg"},{"name":"lithium","range":"(10 – 500) mg/kg"},{"name":"magnesium","range":"(100 – 500000) mg/kg"},{"name":"manganese","range":"(10 – 1000) mg/kg"},{"name":"copper","range":"(1,0 – 5000) mg/kg"},{"name":"molybdenum","range":"(1,0 – 1000) mg/kg"},{"name":"nickel","range":"(1,0 – 5000) mg/kg"},{"name":"lead","range":"(1,0 – 5000) mg/kg"},{"name":"potassium","range":"(100 – 50000) mg/kg"},{"name":"mercury","range":"(0,10 – 100) mg/kg"},{"name":"selenium","range":"(2,0 – 500) mg/kg"},{"name":"silver","range":"(2,0 – 500) mg/kg"},{"name":"strontium","range":"(10 – 1000) mg/kg"},{"name":"sodium","range":"(200 – 50000) mg/kg"},{"name":"thallium","range":"(0,20 – 500) mg/kg"},{"name":"titanium","range":"(2,0 – 500) mg/kg"},{"name":"uranium","range":"(2,0 – 500) mg/kg"},{"name":"vanadium","range":"(2,0 – 500) mg/kg"},{"name":"calcium","range":"(200 – 500000) mg/kg"},{"name":"iron","range":"(20 – 50000) mg/kg"}],"search_en":"Soil Element content Inductively coupled plasma mass spectrometry (ICP-MS) antimony arsenic barium beryllium boron chromium tin zinc phosphorus aluminium cadmium cobalt silicon lithium magnesium manganese copper molybdenum nickel lead potassium mercury selenium silver strontium sodium thallium titanium uranium vanadium calcium iron PN-EN 16171:2017-02 | PN-ISO 11466:2002 | PN-EN ISO 17294-2:2024-04 | PN-EN 13657:2006","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Soil","methodology_zh":"元素含量","parameters_zh":[{"name":"锑","range":"(2,0 – 500) mg/kg"},{"name":"砷","range":"(0,50 – 100) mg/kg"},{"name":"钡","range":"(1,0 – 5000) mg/kg"},{"name":"铍","range":"(2,0 – 100) mg/kg"},{"name":"硼","range":"(50 – 1000) mg/kg"},{"name":"铬","range":"(1,0 – 500) mg/kg"},{"name":"锡","range":"(1,0 – 100) mg/kg"},{"name":"锌","range":"(5,0 – 5000) mg/kg"},{"name":"磷","range":"(20 – 1000) mg/kg"},{"name":"铝","range":"(20 – 1000) mg/kg"},{"name":"镉","range":"(0,20 – 100) mg/kg"},{"name":"钴","range":"(1,0 – 1000) mg/kg"},{"name":"硅","range":"(1000 – 5000) mg/kg"},{"name":"锂","range":"(10 – 500) mg/kg"},{"name":"镁","range":"(100 – 500000) mg/kg"},{"name":"锰","range":"(10 – 1000) mg/kg"},{"name":"铜","range":"(1,0 – 5000) mg/kg"},{"name":"钼","range":"(1,0 – 1000) mg/kg"},{"name":"镍","range":"(1,0 – 5000) mg/kg"},{"name":"铅","range":"(1,0 – 5000) mg/kg"},{"name":"钾","range":"(100 – 50000) mg/kg"},{"name":"汞","range":"(0,10 – 100) mg/kg"},{"name":"硒","range":"(2,0 – 500) mg/kg"},{"name":"银","range":"(2,0 – 500) mg/kg"},{"name":"锶","range":"(10 – 1000) mg/kg"},{"name":"钠","range":"(200 – 50000) mg/kg"},{"name":"铊","range":"(0,20 – 500) mg/kg"},{"name":"钛","range":"(2,0 – 500) mg/kg"},{"name":"铀","range":"(2,0 – 500) mg/kg"},{"name":"钒","range":"(2,0 – 500) mg/kg"},{"name":"钙","range":"(200 – 500000) mg/kg"},{"name":"铁","range":"(20 – 50000) mg/kg"}],"search_zh":"土壤 元素含量 电感耦合等离子体质谱法（ICP-MS） 锑 砷 钡 铍 硼 铬 锡 锌 磷 铝 镉 钴 硅 锂 镁 锰 铜 钼 镍 铅 钾 汞 硒 银 锶 钠 铊 钛 铀 钒 钙 铁 PN-EN 16171:2017-02 | PN-ISO 11466:2002 | PN-EN ISO 17294-2:2024-04 | PN-EN 13657:2006","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"土壤"},{"_id":"6a832b7f884ede9a1b2c556f","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość polichlorowanych bifenyli (PCB)","parameters":[{"name":"PCB 28","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 52","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 101","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 118","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 138","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 153","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 180","range":"(0,020 – 2,5) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Zawartość polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,020 – 2,5) mg/kg\nPCB 52 (0,020 – 2,5) mg/kg\nPCB 101 (0,020 – 2,5) mg/kg\nPCB 118 (0,020 – 2,5) mg/kg\nPCB 138 (0,020 – 2,5) mg/kg\nPCB 153 (0,020 – 2,5) mg/kg\nPCB 180 (0,020 – 2,5) mg/kg\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PB/I/39/B:10.04.2017","norm_bases":["PB/I/39/B:10.04.2017"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,020 – 2,5) mg/kg\nPCB 52 (0,020 – 2,5) mg/kg\nPCB 101 (0,020 – 2,5) mg/kg\nPCB 118 (0,020 – 2,5) mg/kg\nPCB 138 (0,020 – 2,5) mg/kg\nPCB 153 (0,020 – 2,5) mg/kg\nPCB 180 (0,020 – 2,5) mg/kg\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PB/I/39/B:10.04.2017 Gleba Zawartosc polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,020 – 2,5) mg/kg\nPCB 52 (0,020 – 2,5) mg/kg\nPCB 101 (0,020 – 2,5) mg/kg\nPCB 118 (0,020 – 2,5) mg/kg\nPCB 138 (0,020 – 2,5) mg/kg\nPCB 153 (0,020 – 2,5) mg/kg\nPCB 180 (0,020 – 2,5) mg/kg\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PB/I/39/B:10.04.2017","categories":["environment"],"row_index":167,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polychlorinated biphenyls (PCB) content","parameters_en":[{"name":"PCB 28","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 52","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 101","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 118","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 138","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 153","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 180","range":"(0,020 – 2,5) mg/kg"}],"search_en":"Soil Polychlorinated biphenyls (PCB) content Gas chromatography with electron capture detection (GC-ECD) PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 PB/I/39/B:10.04.2017","technique_en":"Gas chromatography with electron capture detection (GC-ECD)","test_object_en":"Soil","search_zh":"土壤 多氯联苯（PCB）含量 气相色谱-电子捕获检测法（GC-ECD） PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 PB/I/39/B:10.04.2017","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"土壤","parameters_zh":[{"name":"PCB 28","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 52","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 101","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 118","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 138","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 153","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 180","range":"(0,020 – 2,5) mg/kg"}],"methodology_zh":"多氯联苯（PCB）含量"},{"_id":"6a832b7f884ede9a1b2c5570","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Suma PCB (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma PCB (z obliczeń)","reference":"PB/I/39/B:10.04.2017","norm_bases":["PB/I/39/B:10.04.2017"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Suma PCB (z obliczeń) PB/I/39/B:10.04.2017 Gleba Suma PCB (z obliczen) PB/I/39/B:10.04.2017","categories":["environment"],"row_index":168,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of PCB (calculated)","search_en":"Soil Sum of PCB (calculated) PB/I/39/B:10.04.2017","test_object_en":"Soil","search_zh":"土壤 PCB 总量（由计算得出） PB/I/39/B:10.04.2017","test_object_zh":"土壤","methodology_zh":"PCB 总量（由计算得出）"},{"_id":"6a832b7f884ede9a1b2c5571","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość rtęci","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość rtęci","reference":"PN-ISO 11466:2002","norm_bases":["PN-ISO 11466:2002"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość rtęci PN-ISO 11466:2002 Gleba Zawartosc rteci PN-ISO 11466:2002","categories":["environment"],"row_index":169,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","search_en":"Soil Mercury content PN-ISO 11466:2002","test_object_en":"Soil","methodology_zh":"汞含量","search_zh":"土壤 汞含量 PN-ISO 11466:2002","test_object_zh":"土壤"},{"_id":"6a832b7f884ede9a1b2c5572","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"","parameters":[{"name":"Zakres","range":"(0,05 – 25,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zakres (0,05 – 25,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-ISO 16772:2009","norm_bases":["PN-ISO 16772:2009"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zakres (0,05 – 25,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-ISO 16772:2009 Gleba Zakres (0,05 – 25,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-ISO 16772:2009","categories":["environment"],"row_index":170,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,05 – 25,0) mg/kg"}],"search_en":"Soil Cold vapour atomic absorption spectrometry (CVAAS) Range PN-ISO 16772:2009","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,05 – 25,0) mg/kg"}],"search_zh":"土壤 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-ISO 16772:2009","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"土壤"},{"_id":"6a832b7f884ede9a1b2c5573","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość siarczanów rozpuszczalnych w wodzie Zawartość siarczanów rozpuszczalnych w kwasie","parameters":[{"name":"Zakres","range":"(100 – 50000) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość siarczanów rozpuszczalnych w wodzie Zawartość siarczanów rozpuszczalnych w kwasie\nZakres (100 – 50000) mg/kg\nMetoda wagowa","reference":"PN-ISO 11048:2002","norm_bases":["PN-ISO 11048:2002"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość siarczanów rozpuszczalnych w wodzie Zawartość siarczanów rozpuszczalnych w kwasie\nZakres (100 – 50000) mg/kg\nMetoda wagowa PN-ISO 11048:2002 Gleba Zawartosc siarczanow rozpuszczalnych w wodzie Zawartosc siarczanow rozpuszczalnych w kwasie\nZakres (100 – 50000) mg/kg\nMetoda wagowa PN-ISO 11048:2002","categories":["environment"],"row_index":171,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of water-soluble sulfates Content of acid-soluble sulfates","parameters_en":[{"name":"Range","range":"(100 – 50000) mg/kg"}],"search_en":"Soil Content of water-soluble sulfates Content of acid-soluble sulfates Gravimetric method Range PN-ISO 11048:2002","technique_en":"Gravimetric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(100 – 50000) mg/kg"}],"search_zh":"土壤 重量法 范围 PN-ISO 11048:2002","technique_zh":"重量法","test_object_zh":"土壤"},{"_id":"6a832b7f884ede9a1b2c5574","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość siarczków","parameters":[{"name":"Zakres","range":"(2,0 – 100) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość siarczków\nZakres (2,0 – 100) mg/kg\nMetoda miareczkowa","reference":"PB/FCH/22/C:10.04.2017","norm_bases":["PB/FCH/22/C:10.04.2017"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość siarczków\nZakres (2,0 – 100) mg/kg\nMetoda miareczkowa PB/FCH/22/C:10.04.2017 Gleba Zawartosc siarczkow\nZakres (2,0 – 100) mg/kg\nMetoda miareczkowa PB/FCH/22/C:10.04.2017","categories":["environment"],"row_index":172,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfide content","parameters_en":[{"name":"Range","range":"(2,0 – 100) mg/kg"}],"search_en":"Soil Sulfide content Titrimetric method Range PB/FCH/22/C:10.04.2017","technique_en":"Titrimetric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(2,0 – 100) mg/kg"}],"search_zh":"土壤 硫化物含量 滴定法 范围 PB/FCH/22/C:10.04.2017","technique_zh":"滴定法","test_object_zh":"土壤","methodology_zh":"硫化物含量"},{"_id":"6a832b7f884ede9a1b2c5575","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(0,02 – 2,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki\nZakres (0,02 – 2,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 15178:2004 PB/FCH/87/A:24.02.2014","norm_bases":["PN-EN 15178:2004 PB/FCH/87/A:24.02.2014"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość siarki\nZakres (0,02 – 2,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 15178:2004 PB/FCH/87/A:24.02.2014 Gleba Zawartosc siarki\nZakres (0,02 – 2,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 15178:2004 PB/FCH/87/A:24.02.2014","categories":["environment"],"row_index":173,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(0,02 – 2,0) %"}],"search_en":"Soil Sulfur content High-temperature combustion with IR detection Range PN-EN 15178:2004 PB/FCH/87/A:24.02.2014","technique_en":"High-temperature combustion with IR detection","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,02 – 2,0) %"}],"search_zh":"土壤 硫含量 高温燃烧红外检测法 范围 PN-EN 15178:2004 PB/FCH/87/A:24.02.2014","technique_zh":"高温燃烧红外检测法","test_object_zh":"土壤","methodology_zh":"硫含量"},{"_id":"6a832b7f884ede9a1b2c5576","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Sucha masa / zawartość wody","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa / zawartość wody\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02","norm_bases":["PN-EN 15934:2013-02"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Sucha masa / zawartość wody\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15934:2013-02 Gleba Sucha masa / zawartosc wody\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15934:2013-02","categories":["water","environment"],"row_index":174,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter / water content","parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"search_en":"Soil Dry matter / water content Gravimetric method Range PN-EN 15934:2013-02","technique_en":"Gravimetric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"土壤 干物质 / 水分含量 重量法 范围 PN-EN 15934:2013-02","technique_zh":"重量法","test_object_zh":"土壤","methodology_zh":"干物质 / 水分含量"},{"_id":"6a832b7f884ede9a1b2c5577","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, Osady ściekowe","methodology":"Straty przy prażeniu (LOI) / substancje organiczne","parameters":[{"name":"Zakres","range":"(0,1 – 99,5) %"}],"technique":"Metoda termograwimetryczna","techniques":["Metoda termograwimetryczna"],"computed":[],"activity":"Straty przy prażeniu (LOI) / substancje organiczne\nZakres (0,1 – 99,5) %\nMetoda termograwimetryczna","reference":"PN-EN 15935:2022-01 | PN-EN 15169:2011","norm_bases":["PN-EN 15935:2022-01","PN-EN 15169:2011"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, Osady ściekowe Straty przy prażeniu (LOI) / substancje organiczne\nZakres (0,1 – 99,5) %\nMetoda termograwimetryczna PN-EN 15935:2022-01 | PN-EN 15169:2011 Gleba, Osady sciekowe Straty przy prazeniu (LOI) / substancje organiczne\nZakres (0,1 – 99,5) %\nMetoda termograwimetryczna PN-EN 15935:2022-01 | PN-EN 15169:2011","categories":["water","environment"],"row_index":175,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition (LOI) / organic matter","parameters_en":[{"name":"Range","range":"(0,1 – 99,5) %"}],"search_en":"Soil, Sewage sludge Loss on ignition (LOI) / organic matter Thermogravimetric method Range PN-EN 15935:2022-01 | PN-EN 15169:2011","technique_en":"Thermogravimetric method","test_object_en":"Soil, Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,1 – 99,5) %"}],"search_zh":"土壤、污泥 烧失量（LOI）/ 有机物质 热重法 范围 PN-EN 15935:2022-01 | PN-EN 15169:2011","test_object_zh":"土壤、污泥","technique_zh":"热重法","methodology_zh":"烧失量（LOI）/ 有机物质"},{"_id":"6a832b7f884ede9a1b2c5578","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość przyswajalnego fosforu","parameters":[{"name":"Zakres","range":"(1,0 – 50) mg/100g P2O5"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość przyswajalnego fosforu\nZakres (1,0 – 50) mg/100g P2O5\nMetoda spektrofotometryczna","reference":"PN-R-04023:1996","norm_bases":["PN-R-04023:1996"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość przyswajalnego fosforu\nZakres (1,0 – 50) mg/100g P2O5\nMetoda spektrofotometryczna PN-R-04023:1996 Gleba mineralna Zawartosc przyswajalnego fosforu\nZakres (1,0 – 50) mg/100g P2O5\nMetoda spektrofotometryczna PN-R-04023:1996","categories":["environment"],"row_index":176,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Available phosphorus content","parameters_en":[{"name":"Range","range":"(1,0 – 50) mg/100g P2O5"}],"search_en":"Mineral soil Available phosphorus content Spectrophotometric method Range PN-R-04023:1996","technique_en":"Spectrophotometric method","test_object_en":"Mineral soil","parameters_zh":[{"name":"范围","range":"(1,0 – 50) mg/100g P2O5"}],"search_zh":"矿质土壤 有效磷含量 分光光度法 范围 PN-R-04023:1996","technique_zh":"分光光度法","test_object_zh":"矿质土壤","methodology_zh":"有效磷含量"},{"_id":"6a832b7f884ede9a1b2c5579","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość przyswajalnego fosforu (P2O5)","parameters":[{"name":"Zakres","range":"(1,0 – 100) mg/100 g"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość przyswajalnego fosforu (P2O5)\nZakres (1,0 – 100) mg/100 g\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-R-04023:1996 | PN-EN ISO 11885:2009","norm_bases":["PN-R-04023:1996","PN-EN ISO 11885:2009"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość przyswajalnego fosforu (P2O5)\nZakres (1,0 – 100) mg/100 g\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-R-04023:1996 | PN-EN ISO 11885:2009 Gleba mineralna Zawartosc przyswajalnego fosforu (P2O5)\nZakres (1,0 – 100) mg/100 g\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-R-04023:1996 | PN-EN ISO 11885:2009","categories":["environment"],"row_index":177,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Available phosphorus content (P2O5)","parameters_en":[{"name":"Range","range":"(1,0 – 100) mg/100 g"}],"search_en":"Mineral soil Available phosphorus content (P2O5) Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-R-04023:1996 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Mineral soil","parameters_zh":[{"name":"范围","range":"(1,0 – 100) mg/100 g"}],"search_zh":"矿质土壤 速效磷含量（P2O5） 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-R-04023:1996 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"矿质土壤","methodology_zh":"速效磷含量（P2O5）"},{"_id":"6a832b7f884ede9a1b2c557a","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość przyswajalnego potasu (K2O)","parameters":[{"name":"Zakres","range":"(5,0 – 120) mg/100 g"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość przyswajalnego potasu (K2O)\nZakres (5,0 – 120) mg/100 g\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-R-04022:1996+Az1:2002 | PN-EN ISO 11885:2009","norm_bases":["PN-R-04022:1996+Az1:2002","PN-EN ISO 11885:2009"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość przyswajalnego potasu (K2O)\nZakres (5,0 – 120) mg/100 g\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-R-04022:1996+Az1:2002 | PN-EN ISO 11885:2009 Gleba mineralna Zawartosc przyswajalnego potasu (K2O)\nZakres (5,0 – 120) mg/100 g\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-R-04022:1996+Az1:2002 | PN-EN ISO 11885:2009","categories":["environment"],"row_index":178,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Available potassium (K2O) content","parameters_en":[{"name":"Range","range":"(5,0 – 120) mg/100 g"}],"search_en":"Mineral soil Available potassium (K2O) content Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-R-04022:1996+Az1:2002 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Mineral soil","parameters_zh":[{"name":"范围","range":"(5,0 – 120) mg/100 g"}],"search_zh":"矿质土壤 速效钾含量（K2O） 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-R-04022:1996+Az1:2002 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"矿质土壤","methodology_zh":"速效钾含量（K2O）"},{"_id":"6a832b7f884ede9a1b2c557b","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość przyswajalnego magnezu (MgO)","parameters":[{"name":"Zakres","range":"(1,0 – 150) mg/100 g"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość przyswajalnego magnezu (MgO)\nZakres (1,0 – 150) mg/100 g\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-R-04020:1994+Az1:1994 | PN-EN ISO 11885:2009","norm_bases":["PN-R-04020:1994+Az1:1994","PN-EN ISO 11885:2009"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość przyswajalnego magnezu (MgO)\nZakres (1,0 – 150) mg/100 g\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-R-04020:1994+Az1:1994 | PN-EN ISO 11885:2009 Gleba mineralna Zawartosc przyswajalnego magnezu (MgO)\nZakres (1,0 – 150) mg/100 g\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-R-04020:1994+Az1:1994 | PN-EN ISO 11885:2009","categories":["environment"],"row_index":179,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of available magnesium (MgO)","parameters_en":[{"name":"Range","range":"(1,0 – 150) mg/100 g"}],"search_en":"Mineral soil Content of available magnesium (MgO) Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-R-04020:1994+Az1:1994 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Mineral soil","parameters_zh":[{"name":"范围","range":"(1,0 – 150) mg/100 g"}],"search_zh":"矿质土壤 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-R-04020:1994+Az1:1994 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"矿质土壤"},{"_id":"6a832b7f884ede9a1b2c557c","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba organiczna","methodology":"Zawartość przyswajalnego fosforu","parameters":[{"name":"Zakres","range":"(12,5 – 250) mg/100g P2O5"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość przyswajalnego fosforu\nZakres (12,5 – 250) mg/100g P2O5\nMetoda spektrofotometryczna","reference":"PN-R-04024:1997","norm_bases":["PN-R-04024:1997"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba organiczna Zawartość przyswajalnego fosforu\nZakres (12,5 – 250) mg/100g P2O5\nMetoda spektrofotometryczna PN-R-04024:1997 Gleba organiczna Zawartosc przyswajalnego fosforu\nZakres (12,5 – 250) mg/100g P2O5\nMetoda spektrofotometryczna PN-R-04024:1997","categories":["environment"],"row_index":180,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Available phosphorus content","parameters_en":[{"name":"Range","range":"(12,5 – 250) mg/100g P2O5"}],"search_en":"Organic soil Available phosphorus content Spectrophotometric method Range PN-R-04024:1997","technique_en":"Spectrophotometric method","test_object_en":"Organic soil","parameters_zh":[{"name":"范围","range":"(12,5 – 250) mg/100g P2O5"}],"search_zh":"有机土壤 有效磷含量 分光光度法 范围 PN-R-04024:1997","technique_zh":"分光光度法","methodology_zh":"有效磷含量","test_object_zh":"有机土壤"},{"_id":"6a832b7f884ede9a1b2c557d","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba organiczna","methodology":"Zawartość przyswajalnych form pierwiastków","parameters":[{"name":"magnez (1,0 – 150) mg/100 g MgO potas","range":"(5,0 – 120) mg/100g K2O"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość przyswajalnych form pierwiastków\nmagnez (1,0 – 150) mg/100 g MgO potas (5,0 – 120) mg/100g K2O\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-R-04024:1997 | PN-EN ISO 11885:2009","norm_bases":["PN-R-04024:1997","PN-EN ISO 11885:2009"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba organiczna Zawartość przyswajalnych form pierwiastków\nmagnez (1,0 – 150) mg/100 g MgO potas (5,0 – 120) mg/100g K2O\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-R-04024:1997 | PN-EN ISO 11885:2009 Gleba organiczna Zawartosc przyswajalnych form pierwiastkow\nmagnez (1,0 – 150) mg/100 g MgO potas (5,0 – 120) mg/100g K2O\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-R-04024:1997 | PN-EN ISO 11885:2009","categories":["environment"],"row_index":181,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of available forms of elements","parameters_en":[{"name":"magnesium (1,0 – 150) mg/100 g MgO potassium","range":"(5,0 – 120) mg/100g K2O"}],"search_en":"Organic soil Content of available forms of elements Inductively coupled plasma optical emission spectrometry (ICP-OES) magnesium (1,0 – 150) mg/100 g MgO potassium PN-R-04024:1997 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Organic soil","search_zh":"有机土壤 电感耦合等离子体原子发射光谱法（ICP-OES） PN-R-04024:1997 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"有机土壤"},{"_id":"6a832b7f884ede9a1b2c557e","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Stabilizat","methodology":"Straty przy prażeniu (LOI) / substancje organiczne","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu (LOI) / substancje organiczne\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stabilizat Straty przy prażeniu (LOI) / substancje organiczne\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15935:2022-01 Stabilizat Straty przy prazeniu (LOI) / substancje organiczne\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["other"],"row_index":182,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition (LOI) / organic matter","parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"search_en":"Stabilised waste Loss on ignition (LOI) / organic matter Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Stabilised waste","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"稳定化产物 烧失量（LOI）/ 有机物质 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","methodology_zh":"烧失量（LOI）/ 有机物质","test_object_zh":"稳定化产物"},{"_id":"6a832b7f884ede9a1b2c557f","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Stabilizat","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(5,0 – 40,0) %"},{"name":"Sucha masa"},{"name":"Zakres","range":"(60,0 – 95,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wody\nZakres:\nZakres (5,0 – 40,0) %\nSucha masa\nZakres (60,0 – 95,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 metoda A","norm_bases":["PN-EN 15934:2013-02 metoda A"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stabilizat Zawartość wody\nZakres:\nZakres (5,0 – 40,0) %\nSucha masa\nZakres (60,0 – 95,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A Stabilizat Zawartosc wody\nZakres:\nZakres (5,0 – 40,0) %\nSucha masa\nZakres (60,0 – 95,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A","categories":["water"],"row_index":183,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(5,0 – 40,0) %"},{"name":"Dry matter"},{"name":"Range","range":"(60,0 – 95,0) %"}],"search_en":"Stabilised waste Water content Gravimetric method Range Dry matter Range PN-EN 15934:2013-02 metoda A","technique_en":"Gravimetric method","test_object_en":"Stabilised waste","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(5,0 – 40,0) %"},{"name":"干物质"},{"name":"范围","range":"(60,0 – 95,0) %"}],"search_zh":"稳定化产物 水分含量 重量法 范围 干物质 范围 PN-EN 15934:2013-02 metoda A","technique_zh":"重量法","test_object_zh":"稳定化产物"},{"_id":"6a832b7f884ede9a1b2c5580","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Kompost, biomasa, stabilizat","methodology":"Aktywność oddechowa AT4","parameters":[{"name":"Zakres","range":"(1,0 – 20,0) mg/g"}],"technique":"Metoda manometryczna","techniques":["Metoda manometryczna"],"computed":[],"activity":"Aktywność oddechowa AT4\nZakres (1,0 – 20,0) mg/g\nMetoda manometryczna","reference":"PB/FCH/82/C:04.06.2018","norm_bases":["PB/FCH/82/C:04.06.2018"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kompost, biomasa, stabilizat Aktywność oddechowa AT4\nZakres (1,0 – 20,0) mg/g\nMetoda manometryczna PB/FCH/82/C:04.06.2018 Kompost, biomasa, stabilizat Aktywnosc oddechowa AT4\nZakres (1,0 – 20,0) mg/g\nMetoda manometryczna PB/FCH/82/C:04.06.2018","categories":["metrology"],"row_index":184,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Respiration activity AT4","parameters_en":[{"name":"Range","range":"(1,0 – 20,0) mg/g"}],"search_en":"Compost, biomass, stabilised waste Respiration activity AT4 Manometric method Range PB/FCH/82/C:04.06.2018","technique_en":"Manometric method","test_object_en":"Compost, biomass, stabilised waste","parameters_zh":[{"name":"范围","range":"(1,0 – 20,0) mg/g"}],"search_zh":"堆肥、生物质、稳定化产物 呼吸活性 AT4 压力计法 范围 PB/FCH/82/C:04.06.2018","technique_zh":"压力计法","test_object_zh":"堆肥、生物质、稳定化产物","methodology_zh":"呼吸活性 AT4"},{"_id":"6a832b7f884ede9a1b2c5581","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Kompost, biomasa, stabilizat","methodology":"Zawartość pierwiastków","parameters":[{"name":"antymon","range":"(5,00 –100) mg/kg"},{"name":"arsen","range":"(5,00 –100) mg/kg"},{"name":"bar","range":"(0,10 –100) mg/kg"},{"name":"beryl","range":"(0,10 – 20) mg/kg"},{"name":"bizmut","range":"(1,00 – 10) mg/kg"},{"name":"bor","range":"(1,50 – 50) mg/kg"},{"name":"chrom","range":"(0,30 – 100) mg/kg"},{"name":"cyna","range":"(5,00 – 100) mg/kg"},{"name":"cynk","range":"(0,50 – 1000) mg/kg"},{"name":"fosfor","range":"(5,00 – 10000) mg/kg"},{"name":"glin","range":"(1,00 – 100) mg/kg"},{"name":"kadm","range":"(0,05 – 20) mg/kg"},{"name":"krzem","range":"(5,00 – 100) mg/kg"},{"name":"kobalt","range":"(0,20 – 20) mg/kg"},{"name":"magnez","range":"(0,70 – 2500) mg/kg"},{"name":"mangan","range":"(0,10 – 50) mg/kg"},{"name":"miedź","range":"(0,40 – 500) mg/kg"},{"name":"molibden","range":"(0,40 – 10) mg/kg"},{"name":"nikiel","range":"(0,40 – 100 ) mg/kg"},{"name":"ołów","range":"(1,00 – 300) mg/kg"},{"name":"potas","range":"(100 – 1000) mg/kg"},{"name":"sód","range":"(100 – 5000) mg/kg"},{"name":"srebro","range":"(0,10 – 10) mg/kg"},{"name":"stront","range":"(0,30 – 50) mg/kg"},{"name":"tal","range":"(5,00 – 10) mg/kg"},{"name":"tytan","range":"(0,10 – 10) mg/kg"},{"name":"wanad","range":"(0,50 – 50) mg/kg"},{"name":"wapń","range":"(1,00 – 25000) mg/kg"},{"name":"żelazo","range":"(0,40 – 1500) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nantymon (5,00 –100) mg/kg\narsen (5,00 –100) mg/kg\nbar (0,10 –100) mg/kg\nberyl (0,10 – 20) mg/kg\nbizmut (1,00 – 10) mg/kg\nbor (1,50 – 50) mg/kg\nchrom (0,30 – 100) mg/kg\ncyna (5,00 – 100) mg/kg\ncynk (0,50 – 1000) mg/kg\nfosfor (5,00 – 10000) mg/kg\nglin (1,00 – 100) mg/kg\nkadm (0,05 – 20) mg/kg\nkrzem (5,00 – 100) mg/kg\nkobalt (0,20 – 20) mg/kg\nmagnez (0,70 – 2500) mg/kg\nmangan (0,10 – 50) mg/kg\nmiedź (0,40 – 500) mg/kg\nmolibden (0,40 – 10) mg/kg\nnikiel (0,40 – 100 ) mg/kg\nołów (1,00 – 300) mg/kg\npotas (100 – 1000) mg/kg\nsód (100 – 5000) mg/kg\nsrebro (0,10 – 10) mg/kg\nstront (0,30 – 50) mg/kg\ntal (5,00 – 10) mg/kg\ntytan (0,10 – 10) mg/kg\nwanad (0,50 – 50) mg/kg\nwapń (1,00 – 25000) mg/kg\nżelazo (0,40 – 1500) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 16174:2012 | PN-EN 22036:2024-07","norm_bases":["PN-EN 16174:2012","PN-EN 22036:2024-07"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kompost, biomasa, stabilizat Zawartość pierwiastków\nZakres:\nantymon (5,00 –100) mg/kg\narsen (5,00 –100) mg/kg\nbar (0,10 –100) mg/kg\nberyl (0,10 – 20) mg/kg\nbizmut (1,00 – 10) mg/kg\nbor (1,50 – 50) mg/kg\nchrom (0,30 – 100) mg/kg\ncyna (5,00 – 100) mg/kg\ncynk (0,50 – 1000) mg/kg\nfosfor (5,00 – 10000) mg/kg\nglin (1,00 – 100) mg/kg\nkadm (0,05 – 20) mg/kg\nkrzem (5,00 – 100) mg/kg\nkobalt (0,20 – 20) mg/kg\nmagnez (0,70 – 2500) mg/kg\nmangan (0,10 – 50) mg/kg\nmiedź (0,40 – 500) mg/kg\nmolibden (0,40 – 10) mg/kg\nnikiel (0,40 – 100 ) mg/kg\nołów (1,00 – 300) mg/kg\npotas (100 – 1000) mg/kg\nsód (100 – 5000) mg/kg\nsrebro (0,10 – 10) mg/kg\nstront (0,30 – 50) mg/kg\ntal (5,00 – 10) mg/kg\ntytan (0,10 – 10) mg/kg\nwanad (0,50 – 50) mg/kg\nwapń (1,00 – 25000) mg/kg\nżelazo (0,40 – 1500) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 16174:2012 | PN-EN 22036:2024-07 Kompost, biomasa, stabilizat Zawartosc pierwiastkow\nZakres:\nantymon (5,00 –100) mg/kg\narsen (5,00 –100) mg/kg\nbar (0,10 –100) mg/kg\nberyl (0,10 – 20) mg/kg\nbizmut (1,00 – 10) mg/kg\nbor (1,50 – 50) mg/kg\nchrom (0,30 – 100) mg/kg\ncyna (5,00 – 100) mg/kg\ncynk (0,50 – 1000) mg/kg\nfosfor (5,00 – 10000) mg/kg\nglin (1,00 – 100) mg/kg\nkadm (0,05 – 20) mg/kg\nkrzem (5,00 – 100) mg/kg\nkobalt (0,20 – 20) mg/kg\nmagnez (0,70 – 2500) mg/kg\nmangan (0,10 – 50) mg/kg\nmiedz (0,40 – 500) mg/kg\nmolibden (0,40 – 10) mg/kg\nnikiel (0,40 – 100 ) mg/kg\nolow (1,00 – 300) mg/kg\npotas (100 – 1000) mg/kg\nsod (100 – 5000) mg/kg\nsrebro (0,10 – 10) mg/kg\nstront (0,30 – 50) mg/kg\ntal (5,00 – 10) mg/kg\ntytan (0,10 – 10) mg/kg\nwanad (0,50 – 50) mg/kg\nwapn (1,00 – 25000) mg/kg\nzelazo (0,40 – 1500) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 16174:2012 | PN-EN 22036:2024-07","categories":["materials"],"row_index":185,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","parameters_en":[{"name":"antimony","range":"(5,00 –100) mg/kg"},{"name":"arsenic","range":"(5,00 –100) mg/kg"},{"name":"barium","range":"(0,10 –100) mg/kg"},{"name":"beryllium","range":"(0,10 – 20) mg/kg"},{"name":"bismuth","range":"(1,00 – 10) mg/kg"},{"name":"boron","range":"(1,50 – 50) mg/kg"},{"name":"chromium","range":"(0,30 – 100) mg/kg"},{"name":"tin","range":"(5,00 – 100) mg/kg"},{"name":"zinc","range":"(0,50 – 1000) mg/kg"},{"name":"phosphorus","range":"(5,00 – 10000) mg/kg"},{"name":"aluminium","range":"(1,00 – 100) mg/kg"},{"name":"cadmium","range":"(0,05 – 20) mg/kg"},{"name":"silicon","range":"(5,00 – 100) mg/kg"},{"name":"cobalt","range":"(0,20 – 20) mg/kg"},{"name":"magnesium","range":"(0,70 – 2500) mg/kg"},{"name":"manganese","range":"(0,10 – 50) mg/kg"},{"name":"copper","range":"(0,40 – 500) mg/kg"},{"name":"molybdenum","range":"(0,40 – 10) mg/kg"},{"name":"nickel","range":"(0,40 – 100 ) mg/kg"},{"name":"lead","range":"(1,00 – 300) mg/kg"},{"name":"potassium","range":"(100 – 1000) mg/kg"},{"name":"sodium","range":"(100 – 5000) mg/kg"},{"name":"silver","range":"(0,10 – 10) mg/kg"},{"name":"strontium","range":"(0,30 – 50) mg/kg"},{"name":"thallium","range":"(5,00 – 10) mg/kg"},{"name":"titanium","range":"(0,10 – 10) mg/kg"},{"name":"vanadium","range":"(0,50 – 50) mg/kg"},{"name":"calcium","range":"(1,00 – 25000) mg/kg"},{"name":"iron","range":"(0,40 – 1500) mg/kg"}],"search_en":"Compost, biomass, stabilised waste Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) antimony arsenic barium beryllium bismuth boron chromium tin zinc phosphorus aluminium cadmium silicon cobalt magnesium manganese copper molybdenum nickel lead potassium sodium silver strontium thallium titanium vanadium calcium iron PN-EN 16174:2012 | PN-EN 22036:2024-07","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Compost, biomass, stabilised waste","methodology_zh":"元素含量","parameters_zh":[{"name":"锑","range":"(5,00 –100) mg/kg"},{"name":"砷","range":"(5,00 –100) mg/kg"},{"name":"钡","range":"(0,10 –100) mg/kg"},{"name":"铍","range":"(0,10 – 20) mg/kg"},{"name":"bizmut","range":"(1,00 – 10) mg/kg"},{"name":"硼","range":"(1,50 – 50) mg/kg"},{"name":"铬","range":"(0,30 – 100) mg/kg"},{"name":"锡","range":"(5,00 – 100) mg/kg"},{"name":"锌","range":"(0,50 – 1000) mg/kg"},{"name":"磷","range":"(5,00 – 10000) mg/kg"},{"name":"铝","range":"(1,00 – 100) mg/kg"},{"name":"镉","range":"(0,05 – 20) mg/kg"},{"name":"硅","range":"(5,00 – 100) mg/kg"},{"name":"钴","range":"(0,20 – 20) mg/kg"},{"name":"镁","range":"(0,70 – 2500) mg/kg"},{"name":"锰","range":"(0,10 – 50) mg/kg"},{"name":"铜","range":"(0,40 – 500) mg/kg"},{"name":"钼","range":"(0,40 – 10) mg/kg"},{"name":"镍","range":"(0,40 – 100 ) mg/kg"},{"name":"铅","range":"(1,00 – 300) mg/kg"},{"name":"钾","range":"(100 – 1000) mg/kg"},{"name":"钠","range":"(100 – 5000) mg/kg"},{"name":"银","range":"(0,10 – 10) mg/kg"},{"name":"锶","range":"(0,30 – 50) mg/kg"},{"name":"铊","range":"(5,00 – 10) mg/kg"},{"name":"钛","range":"(0,10 – 10) mg/kg"},{"name":"钒","range":"(0,50 – 50) mg/kg"},{"name":"钙","range":"(1,00 – 25000) mg/kg"},{"name":"铁","range":"(0,40 – 1500) mg/kg"}],"search_zh":"堆肥、生物质、稳定化产物 元素含量 电感耦合等离子体原子发射光谱法（ICP-OES） 锑 砷 钡 铍 硼 铬 锡 锌 磷 铝 镉 硅 钴 镁 锰 铜 钼 镍 铅 钾 钠 银 锶 铊 钛 钒 钙 铁 PN-EN 16174:2012 | PN-EN 22036:2024-07","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"堆肥、生物质、稳定化产物"},{"_id":"6a832b7f884ede9a1b2c5582","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Kompost, biomasa, stabilizat","methodology":"Straty przy prażeniu (LOI) / substancje organiczne","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"technique":"Metoda termograwimetryczna (TGA) badane cechy/metoda","techniques":["Metoda termograwimetryczna (TGA) badane cechy/metoda"],"computed":[],"activity":"Straty przy prażeniu (LOI) / substancje organiczne\nZakres (0,5 – 99,5) %\nMetoda termograwimetryczna (TGA) badane cechy/metoda","reference":"PN-EN 15935:2022-01 Dokumenty odniesienia","norm_bases":["PN-EN 15935:2022-01 Dokumenty odniesienia"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kompost, biomasa, stabilizat Straty przy prażeniu (LOI) / substancje organiczne\nZakres (0,5 – 99,5) %\nMetoda termograwimetryczna (TGA) badane cechy/metoda PN-EN 15935:2022-01 Dokumenty odniesienia Kompost, biomasa, stabilizat Straty przy prazeniu (LOI) / substancje organiczne\nZakres (0,5 – 99,5) %\nMetoda termograwimetryczna (TGA) badane cechy/metoda PN-EN 15935:2022-01 Dokumenty odniesienia","categories":["other"],"row_index":186,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition (LOI) / organic matter","parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"search_en":"Compost, biomass, stabilised waste Loss on ignition (LOI) / organic matter Thermogravimetric method (TGA) tested characteristics/method Range PN-EN 15935:2022-01 Dokumenty odniesienia","technique_en":"Thermogravimetric method (TGA) tested characteristics/method","test_object_en":"Compost, biomass, stabilised waste","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"堆肥、生物质、稳定化产物 烧失量（LOI）/ 有机物质 范围 PN-EN 15935:2022-01 Dokumenty odniesienia","test_object_zh":"堆肥、生物质、稳定化产物","methodology_zh":"烧失量（LOI）/ 有机物质"},{"_id":"6a832b7f884ede9a1b2c5583","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Kompost, biomasa, stabilizat","methodology":"Zawartość wody/ sucha masa","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość wody/ sucha masa\nZakres (0,5 – 99,5) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN 15934:2013-02 metoda A","norm_bases":["PN-EN 15934:2013-02 metoda A"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kompost, biomasa, stabilizat Zawartość wody/ sucha masa\nZakres (0,5 – 99,5) %\nMetoda termograwimetryczna (TGA) PN-EN 15934:2013-02 metoda A Kompost, biomasa, stabilizat Zawartosc wody/ sucha masa\nZakres (0,5 – 99,5) %\nMetoda termograwimetryczna (TGA) PN-EN 15934:2013-02 metoda A","categories":["water"],"row_index":187,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content/ dry matter","parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"search_en":"Compost, biomass, stabilised waste Water content/ dry matter Thermogravimetric method (TGA) Range PN-EN 15934:2013-02 metoda A","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Compost, biomass, stabilised waste","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"堆肥、生物质、稳定化产物 热重法（TGA） 范围 PN-EN 15934:2013-02 metoda A","technique_zh":"热重法（TGA）","test_object_zh":"堆肥、生物质、稳定化产物"},{"_id":"6a832b7f884ede9a1b2c5584","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Kompost, biomasa, stabilizat","methodology":"Zawartość ogólnego węgla organicznego (TOC)","parameters":[{"name":"Zakres","range":"(0,10 – 60) %"},{"name":"Zakres","range":"(1000 – 600000) mg/kg"}],"technique":"Metoda wysoko temperaturowego spalania z detekcją IR","techniques":["Metoda wysoko temperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość ogólnego węgla organicznego (TOC)\nZakres:\nZakres (0,10 – 60) %\nZakres (1000 – 600000) mg/kg\nMetoda wysoko temperaturowego spalania z detekcją IR","reference":"PN EN 15936:2022-07 metoda B","norm_bases":["PN EN 15936:2022-07 metoda B"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kompost, biomasa, stabilizat Zawartość ogólnego węgla organicznego (TOC)\nZakres:\nZakres (0,10 – 60) %\nZakres (1000 – 600000) mg/kg\nMetoda wysoko temperaturowego spalania z detekcją IR PN EN 15936:2022-07 metoda B Kompost, biomasa, stabilizat Zawartosc ogolnego wegla organicznego (TOC)\nZakres:\nZakres (0,10 – 60) %\nZakres (1000 – 600000) mg/kg\nMetoda wysoko temperaturowego spalania z detekcja IR PN EN 15936:2022-07 metoda B","categories":["other"],"row_index":188,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon (TOC) content","parameters_en":[{"name":"Range","range":"(0,10 – 60) %"},{"name":"Range","range":"(1000 – 600000) mg/kg"}],"search_en":"Compost, biomass, stabilised waste Total organic carbon (TOC) content High-temperature combustion with IR detection Range Range PN EN 15936:2022-07 metoda B","technique_en":"High-temperature combustion with IR detection","test_object_en":"Compost, biomass, stabilised waste","parameters_zh":[{"name":"范围","range":"(0,10 – 60) %"},{"name":"范围","range":"(1000 – 600000) mg/kg"}],"search_zh":"堆肥、生物质、稳定化产物 总有机碳（TOC）含量 高温燃烧-红外检测法 范围 范围 PN EN 15936:2022-07 metoda B","methodology_zh":"总有机碳（TOC）含量","test_object_zh":"堆肥、生物质、稳定化产物","technique_zh":"高温燃烧-红外检测法"},{"_id":"6a832b7f884ede9a1b2c5585","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Kompost, biomasa, stabilizat","methodology":"pH – w H2O","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH – w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kompost, biomasa, stabilizat pH – w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Kompost, biomasa, stabilizat pH – w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["other"],"row_index":189,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH – in H2O","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Compost, biomass, stabilised waste pH – in H2O Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Compost, biomass, stabilised waste","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"堆肥、生物质、稳定化产物 pH — 于 H2O 中 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","methodology_zh":"pH — 于 H2O 中","test_object_zh":"堆肥、生物质、稳定化产物"},{"_id":"6a832b7f884ede9a1b2c5586","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Kompost, biomasa, stabilizat","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,070 – 9,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (0,070 – 9,0) %\nMetoda miareczkowa","reference":"PN-75/C-04576/15","norm_bases":["PN-75/C-04576/15"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kompost, biomasa, stabilizat Zawartość azotu amonowego\nZakres (0,070 – 9,0) %\nMetoda miareczkowa PN-75/C-04576/15 Kompost, biomasa, stabilizat Zawartosc azotu amonowego\nZakres (0,070 – 9,0) %\nMetoda miareczkowa PN-75/C-04576/15","categories":["other"],"row_index":190,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,070 – 9,0) %"}],"search_en":"Compost, biomass, stabilised waste Ammonium nitrogen content Titrimetric method Range PN-75/C-04576/15","technique_en":"Titrimetric method","test_object_en":"Compost, biomass, stabilised waste","parameters_zh":[{"name":"范围","range":"(0,070 – 9,0) %"}],"search_zh":"堆肥、生物质、稳定化产物 氨氮含量 滴定法 范围 PN-75/C-04576/15","technique_zh":"滴定法","methodology_zh":"氨氮含量","test_object_zh":"堆肥、生物质、稳定化产物"},{"_id":"6a832b7f884ede9a1b2c5587","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Kompost, biomasa, stabilizat","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,40 – 8,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres (0,40 – 8,0) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kompost, biomasa, stabilizat Zawartość azotu Kjeldahla\nZakres (0,40 – 8,0) %\nMetoda miareczkowa PN-EN 13342:2002 Kompost, biomasa, stabilizat Zawartosc azotu Kjeldahla\nZakres (0,40 – 8,0) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["other"],"row_index":191,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,40 – 8,0) %"}],"search_en":"Compost, biomass, stabilised waste Kjeldahl nitrogen content Titrimetric method Range PN-EN 13342:2002","technique_en":"Titrimetric method","test_object_en":"Compost, biomass, stabilised waste","parameters_zh":[{"name":"范围","range":"(0,40 – 8,0) %"}],"search_zh":"堆肥、生物质、稳定化产物 凯氏氮含量 滴定法 范围 PN-EN 13342:2002","technique_zh":"滴定法","methodology_zh":"凯氏氮含量","test_object_zh":"堆肥、生物质、稳定化产物"},{"_id":"6a832b7f884ede9a1b2c5588","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Kompost, biomasa, stabilizat, Osad ściekowy","methodology":"Zawartość rtęci","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość rtęci","reference":"PN-EN 16174:2012","norm_bases":["PN-EN 16174:2012"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kompost, biomasa, stabilizat, Osad ściekowy Zawartość rtęci PN-EN 16174:2012 Kompost, biomasa, stabilizat, Osad sciekowy Zawartosc rteci PN-EN 16174:2012","categories":["water"],"row_index":192,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","search_en":"Compost, biomass, stabilised waste, Sewage sludge Mercury content PN-EN 16174:2012","test_object_en":"Compost, biomass, stabilised waste, Sewage sludge","methodology_zh":"汞含量","search_zh":"汞含量 PN-EN 16174:2012"},{"_id":"6a832b7f884ede9a1b2c5589","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Kompost, biomasa, stabilizat, Osad ściekowy","methodology":"","parameters":[{"name":"Zakres","range":"(0,05 – 25,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zakres (0,05 – 25,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 16175-1:2017-02","norm_bases":["PN-EN 16175-1:2017-02"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kompost, biomasa, stabilizat, Osad ściekowy Zakres (0,05 – 25,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 16175-1:2017-02 Kompost, biomasa, stabilizat, Osad sciekowy Zakres (0,05 – 25,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 16175-1:2017-02","categories":["water"],"row_index":193,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,05 – 25,0) mg/kg"}],"search_en":"Compost, biomass, stabilised waste, Sewage sludge Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 16175-1:2017-02","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Compost, biomass, stabilised waste, Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,05 – 25,0) mg/kg"}],"search_zh":"冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 16175-1:2017-02","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a832b7f884ede9a1b2c558a","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu","reference":"PN-EN 12457-4:2006","norm_bases":["PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Chemiczne zapotrzebowanie tlenu PN-EN 12457-4:2006 Materialy budowlane: piasek, kruszywo, zuzel Chemiczne zapotrzebowanie tlenu PN-EN 12457-4:2006","categories":["materials","construction"],"row_index":194,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand","search_en":"Construction materials: sand, aggregate, slag Chemical oxygen demand PN-EN 12457-4:2006","test_object_en":"Construction materials: sand, aggregate, slag","methodology_zh":"化学需氧量（COD）","search_zh":"建筑材料：砂、骨料、炉渣 化学需氧量（COD） PN-EN 12457-4:2006","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c558b","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(5,0 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zakres:\nChZT-Cr\nZakres (5,0 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN ISO 15705:2005","norm_bases":["PN ISO 15705:2005"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Zakres:\nChZT-Cr\nZakres (5,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN ISO 15705:2005 Materialy budowlane: piasek, kruszywo, zuzel Zakres:\nChZT-Cr\nZakres (5,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN ISO 15705:2005","categories":["materials","construction"],"row_index":195,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(5,0 – 10000) mg/l O2"}],"search_en":"Construction materials: sand, aggregate, slag Spectrophotometric method COD-Cr Range PN ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(5,0 – 10000) mg/l O2"}],"search_zh":"建筑材料：砂、骨料、炉渣 分光光度法 化学需氧量（COD-Cr） 范围 PN ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c558c","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,005 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,005 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 12457-4:2006 | PN-ISO 6439:1994","norm_bases":["PN-EN 12457-4:2006","PN-ISO 6439:1994"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Indeks fenolowy\nZakres (0,005 – 50,0) mg/l\nMetoda spektrofotometryczna PN-EN 12457-4:2006 | PN-ISO 6439:1994 Materialy budowlane: piasek, kruszywo, zuzel Indeks fenolowy\nZakres (0,005 – 50,0) mg/l\nMetoda spektrofotometryczna PN-EN 12457-4:2006 | PN-ISO 6439:1994","categories":["materials","construction"],"row_index":196,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,005 – 50,0) mg/l"}],"search_en":"Construction materials: sand, aggregate, slag Phenol index Spectrophotometric method Range PN-EN 12457-4:2006 | PN-ISO 6439:1994","technique_en":"Spectrophotometric method","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(0,005 – 50,0) mg/l"}],"search_zh":"建筑材料：砂、骨料、炉渣 酚指数 分光光度法 范围 PN-EN 12457-4:2006 | PN-ISO 6439:1994","technique_zh":"分光光度法","methodology_zh":"酚指数","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c558d","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,050 – 500) mg/kg"},{"name":"CFA"}],"technique":"Metoda ciągłej analizy przepływowej","techniques":["Metoda ciągłej analizy przepływowej"],"computed":[],"activity":"Indeks fenolowy\nZakres:\nZakres (0,050 – 500) mg/kg\nCFA\nMetoda ciągłej analizy przepływowej","reference":"PN-EN 12457-4:2006 | PN-EN ISO 14402:2004, pkt.4","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 14402:2004, pkt.4"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Indeks fenolowy\nZakres:\nZakres (0,050 – 500) mg/kg\nCFA\nMetoda ciągłej analizy przepływowej PN-EN 12457-4:2006 | PN-EN ISO 14402:2004, pkt.4 Materialy budowlane: piasek, kruszywo, zuzel Indeks fenolowy\nZakres:\nZakres (0,050 – 500) mg/kg\nCFA\nMetoda ciaglej analizy przeplywowej PN-EN 12457-4:2006 | PN-EN ISO 14402:2004, pkt.4","categories":["materials","construction"],"row_index":197,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,050 – 500) mg/kg"},{"name":"CFA"}],"search_en":"Construction materials: sand, aggregate, slag Phenol index Continuous flow analysis method Range CFA PN-EN 12457-4:2006 | PN-EN ISO 14402:2004, pkt.4","technique_en":"Continuous flow analysis method","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(0,050 – 500) mg/kg"},{"name":"CFA"}],"search_zh":"建筑材料：砂、骨料、炉渣 酚指数 连续流动分析法 范围 PN-EN 12457-4:2006 | PN-EN ISO 14402:2004, pkt.4","methodology_zh":"酚指数","test_object_zh":"建筑材料：砂、骨料、炉渣","technique_zh":"连续流动分析法"},{"_id":"6a832b7f884ede9a1b2c558e","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN 12457-4:2006 | PN-EN ISO 10523:2012","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 10523:2012"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN 12457-4:2006 | PN-EN ISO 10523:2012 Materialy budowlane: piasek, kruszywo, zuzel pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN 12457-4:2006 | PN-EN ISO 10523:2012","categories":["materials","construction"],"row_index":198,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Construction materials: sand, aggregate, slag pH Potentiometric method Range PN-EN 12457-4:2006 | PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Construction materials: sand, aggregate, slag","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"建筑材料：砂、骨料、炉渣 pH 值 电位法 范围 PN-EN 12457-4:2006 | PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c558f","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10,0 – 50000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10,0 – 50000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 12457-4:2006 | PN-EN 27888:1999","norm_bases":["PN-EN 12457-4:2006","PN-EN 27888:1999"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Przewodność elektryczna właściwa\nZakres (10,0 – 50000) μS/cm\nMetoda konduktometryczna PN-EN 12457-4:2006 | PN-EN 27888:1999 Materialy budowlane: piasek, kruszywo, zuzel Przewodnosc elektryczna wlasciwa\nZakres (10,0 – 50000) μS/cm\nMetoda konduktometryczna PN-EN 12457-4:2006 | PN-EN 27888:1999","categories":["materials","construction"],"row_index":199,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10,0 – 50000) μS/cm"}],"search_en":"Construction materials: sand, aggregate, slag Electrical conductivity Conductometric method Range PN-EN 12457-4:2006 | PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Construction materials: sand, aggregate, slag","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10,0 – 50000) μS/cm"}],"search_zh":"建筑材料：砂、骨料、炉渣 电导率 电导法 范围 PN-EN 12457-4:2006 | PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c5590","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Stężenie anionów","parameters":[{"name":"Siarczany","range":"(2,0 – 100) mg/l"},{"name":"Chlorki","range":"(2,0 – 1000) mg/l"},{"name":"Fluorki","range":"(0,10 – 2,0) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nSiarczany (2,0 – 100) mg/l\nChlorki (2,0 – 1000) mg/l\nFluorki (0,10 – 2,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 10304-1:2009"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Stężenie anionów\nZakres:\nSiarczany (2,0 – 100) mg/l\nChlorki (2,0 – 1000) mg/l\nFluorki (0,10 – 2,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009 Materialy budowlane: piasek, kruszywo, zuzel Stezenie anionow\nZakres:\nSiarczany (2,0 – 100) mg/l\nChlorki (2,0 – 1000) mg/l\nFluorki (0,10 – 2,0) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009","categories":["materials","construction"],"row_index":200,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Sulfates","range":"(2,0 – 100) mg/l"},{"name":"Chlorides","range":"(2,0 – 1000) mg/l"},{"name":"Fluorides","range":"(0,10 – 2,0) mg/l"}],"search_en":"Construction materials: sand, aggregate, slag Anion concentrations Ion chromatography with conductometric detection (IC-CD) Sulfates Chlorides Fluorides PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Construction materials: sand, aggregate, slag","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"硫酸盐","range":"(2,0 – 100) mg/l"},{"name":"氯化物","range":"(2,0 – 1000) mg/l"},{"name":"氟化物","range":"(0,10 – 2,0) mg/l"}],"search_zh":"建筑材料：砂、骨料、炉渣 阴离子浓度 离子色谱-电导检测法（IC-CD） 硫酸盐 氯化物 氟化物 PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c5591","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,20 – 100) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,20 – 100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN 12457-4:2006 | PN-EN ISO 11732:2007","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 11732:2007"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Stężenie azotu amonowego\nZakres (0,20 – 100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN 12457-4:2006 | PN-EN ISO 11732:2007 Materialy budowlane: piasek, kruszywo, zuzel Stezenie azotu amonowego\nZakres (0,20 – 100) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN 12457-4:2006 | PN-EN ISO 11732:2007","categories":["materials","construction"],"row_index":201,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,20 – 100) mg/l"}],"search_en":"Construction materials: sand, aggregate, slag Ammonium nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN 12457-4:2006 | PN-EN ISO 11732:2007","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Construction materials: sand, aggregate, slag","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 100) mg/l"}],"search_zh":"建筑材料：砂、骨料、炉渣 氨氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN 12457-4:2006 | PN-EN ISO 11732:2007","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c5592","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,5 – 2000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,5 – 2000) mg/l\nMetoda miareczkowa","reference":"PN-EN 12457-4:2006 | PN-ISO 5664:2002","norm_bases":["PN-EN 12457-4:2006","PN-ISO 5664:2002"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Stężenie azotu amonowego\nZakres (0,5 – 2000) mg/l\nMetoda miareczkowa PN-EN 12457-4:2006 | PN-ISO 5664:2002 Materialy budowlane: piasek, kruszywo, zuzel Stezenie azotu amonowego\nZakres (0,5 – 2000) mg/l\nMetoda miareczkowa PN-EN 12457-4:2006 | PN-ISO 5664:2002","categories":["materials","construction"],"row_index":202,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 2000) mg/l"}],"search_en":"Construction materials: sand, aggregate, slag Ammonium nitrogen concentration Titrimetric method Range PN-EN 12457-4:2006 | PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Construction materials: sand, aggregate, slag","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,5 – 2000) mg/l"}],"search_zh":"建筑材料：砂、骨料、炉渣 氨氮浓度 滴定法 范围 PN-EN 12457-4:2006 | PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c5593","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,20 – 100) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,20 – 100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN 12457-4:2006 | PN-EN ISO 13395:2001","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 13395:2001"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Stężenie azotu azotanowego\nZakres (0,20 – 100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN 12457-4:2006 | PN-EN ISO 13395:2001 Materialy budowlane: piasek, kruszywo, zuzel Stezenie azotu azotanowego\nZakres (0,20 – 100) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN 12457-4:2006 | PN-EN ISO 13395:2001","categories":["materials","construction"],"row_index":203,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,20 – 100) mg/l"}],"search_en":"Construction materials: sand, aggregate, slag Nitrate nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN 12457-4:2006 | PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Construction materials: sand, aggregate, slag","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 100) mg/l"}],"search_zh":"建筑材料：砂、骨料、炉渣 硝态氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN 12457-4:2006 | PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c5594","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,020 – 2,50) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej(CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej(CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,020 – 2,50) mg/l\nMetoda ciągłej analizy przepływowej(CFA) z detekcją spektrofotometryczną","reference":"PN-EN 12457-4:2006 | PN-EN ISO 13395:2001","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 13395:2001"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Stężenie azotu azotynowego\nZakres (0,020 – 2,50) mg/l\nMetoda ciągłej analizy przepływowej(CFA) z detekcją spektrofotometryczną PN-EN 12457-4:2006 | PN-EN ISO 13395:2001 Materialy budowlane: piasek, kruszywo, zuzel Stezenie azotu azotynowego\nZakres (0,020 – 2,50) mg/l\nMetoda ciaglej analizy przeplywowej(CFA) z detekcja spektrofotometryczna PN-EN 12457-4:2006 | PN-EN ISO 13395:2001","categories":["materials","construction"],"row_index":204,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,020 – 2,50) mg/l"}],"search_en":"Construction materials: sand, aggregate, slag Nitrite nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN 12457-4:2006 | PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Construction materials: sand, aggregate, slag","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 2,50) mg/l"}],"search_zh":"建筑材料：砂、骨料、炉渣 亚硝态氮浓度 范围 PN-EN 12457-4:2006 | PN-EN ISO 13395:2001","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c5595","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,5 – 2000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,5 – 2000) mg/l\nMetoda miareczkowa","reference":"PN-EN 12457-4:2006 | PN-EN 25663:2001","norm_bases":["PN-EN 12457-4:2006","PN-EN 25663:2001"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Stężenie azotu Kjeldahla\nZakres (0,5 – 2000) mg/l\nMetoda miareczkowa PN-EN 12457-4:2006 | PN-EN 25663:2001 Materialy budowlane: piasek, kruszywo, zuzel Stezenie azotu Kjeldahla\nZakres (0,5 – 2000) mg/l\nMetoda miareczkowa PN-EN 12457-4:2006 | PN-EN 25663:2001","categories":["materials","construction"],"row_index":205,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 2000) mg/l"}],"search_en":"Construction materials: sand, aggregate, slag Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 12457-4:2006 | PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Construction materials: sand, aggregate, slag","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,5 – 2000) mg/l"}],"search_zh":"建筑材料：砂、骨料、炉渣 凯氏氮浓度 滴定法 范围 PN-EN 12457-4:2006 | PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c5596","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Stężenie azotu ogólnego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego","reference":"PN-EN 12457-4:2006","norm_bases":["PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Stężenie azotu ogólnego PN-EN 12457-4:2006 Materialy budowlane: piasek, kruszywo, zuzel Stezenie azotu ogolnego PN-EN 12457-4:2006","categories":["materials","construction"],"row_index":206,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration","search_en":"Construction materials: sand, aggregate, slag Total nitrogen concentration PN-EN 12457-4:2006","test_object_en":"Construction materials: sand, aggregate, slag","methodology_zh":"总氮浓度","search_zh":"建筑材料：砂、骨料、炉渣 总氮浓度 PN-EN 12457-4:2006","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c5597","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"(z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"(z obliczeń)","reference":"PB/FCH/6/D:10.04.2017","norm_bases":["PB/FCH/6/D:10.04.2017"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel (z obliczeń) PB/FCH/6/D:10.04.2017 Materialy budowlane: piasek, kruszywo, zuzel (z obliczen) PB/FCH/6/D:10.04.2017","categories":["materials","construction"],"row_index":207,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"(calculated)","search_en":"Construction materials: sand, aggregate, slag (calculated) PB/FCH/6/D:10.04.2017","test_object_en":"Construction materials: sand, aggregate, slag","methodology_zh":"（计算得出）","search_zh":"建筑材料：砂、骨料、炉渣 （计算得出） PB/FCH/6/D:10.04.2017","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c5598","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 10000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 10000) mg/l\nMetoda miareczkowa","reference":"PN-EN 12457-4:2006 | PN-ISO 9297:1994","norm_bases":["PN-EN 12457-4:2006","PN-ISO 9297:1994"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Stężenie chlorków\nZakres (5,0 – 10000) mg/l\nMetoda miareczkowa PN-EN 12457-4:2006 | PN-ISO 9297:1994 Materialy budowlane: piasek, kruszywo, zuzel Stezenie chlorkow\nZakres (5,0 – 10000) mg/l\nMetoda miareczkowa PN-EN 12457-4:2006 | PN-ISO 9297:1994","categories":["materials","construction"],"row_index":208,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 10000) mg/l"}],"search_en":"Construction materials: sand, aggregate, slag Chloride concentration Titrimetric method Range PN-EN 12457-4:2006 | PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Construction materials: sand, aggregate, slag","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 10000) mg/l"}],"search_zh":"建筑材料：砂、骨料、炉渣 氯化物浓度 滴定法 范围 PN-EN 12457-4:2006 | PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c5599","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Stężenie chromu (VI)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chromu (VI)","reference":"PN-EN 12457-4:2006","norm_bases":["PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Stężenie chromu (VI) PN-EN 12457-4:2006 Materialy budowlane: piasek, kruszywo, zuzel Stezenie chromu (VI) PN-EN 12457-4:2006","categories":["materials","construction"],"row_index":209,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) concentration","search_en":"Construction materials: sand, aggregate, slag Chromium(VI) concentration PN-EN 12457-4:2006","test_object_en":"Construction materials: sand, aggregate, slag","search_zh":"建筑材料：砂、骨料、炉渣 六价铬浓度 PN-EN 12457-4:2006","test_object_zh":"建筑材料：砂、骨料、炉渣","methodology_zh":"六价铬浓度"},{"_id":"6a832b7f884ede9a1b2c559a","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"","parameters":[{"name":"Zakres","range":"(0,010 – 5,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zakres (0,010 – 5,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 18412:2007","norm_bases":["PN-EN ISO 18412:2007"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Zakres (0,010 – 5,00) mg/l\nMetoda spektrofotometryczna PN-EN ISO 18412:2007 Materialy budowlane: piasek, kruszywo, zuzel Zakres (0,010 – 5,00) mg/l\nMetoda spektrofotometryczna PN-EN ISO 18412:2007","categories":["materials","construction"],"row_index":210,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,010 – 5,00) mg/l"}],"search_en":"Construction materials: sand, aggregate, slag Spectrophotometric method Range PN-EN ISO 18412:2007","technique_en":"Spectrophotometric method","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(0,010 – 5,00) mg/l"}],"search_zh":"建筑材料：砂、骨料、炉渣 分光光度法 范围 PN-EN ISO 18412:2007","technique_zh":"分光光度法","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c559b","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Stężenie chromu (III) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chromu (III) (z obliczeń)","reference":"PN-EN ISO 18412:2007","norm_bases":["PN-EN ISO 18412:2007"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Stężenie chromu (III) (z obliczeń) PN-EN ISO 18412:2007 Materialy budowlane: piasek, kruszywo, zuzel Stezenie chromu (III) (z obliczen) PN-EN ISO 18412:2007","categories":["materials","construction"],"row_index":211,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium (III) concentration (calculated)","search_en":"Construction materials: sand, aggregate, slag Chromium (III) concentration (calculated) PN-EN ISO 18412:2007","test_object_en":"Construction materials: sand, aggregate, slag","search_zh":"建筑材料：砂、骨料、炉渣 铬(III)浓度（由计算得出） PN-EN ISO 18412:2007","test_object_zh":"建筑材料：砂、骨料、炉渣","methodology_zh":"铬(III)浓度（由计算得出）"},{"_id":"6a832b7f884ede9a1b2c559c","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Stężenie i zawartość cyjanków wolnych i ogólnych","parameters":[{"name":"Zakres","range":"(0,0050 – 10) mg/l"},{"name":"Zakres","range":"(0,050 – 100) mg/kg"},{"name":"Stężenie cyjanków związanych (z obliczeń)"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie i zawartość cyjanków wolnych i ogólnych\nZakres:\nZakres (0,0050 – 10) mg/l\nZakres (0,050 – 100) mg/kg\nStężenie cyjanków związanych (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN 12457-4:2006 | PN-EN ISO 14403-2:2012","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 14403-2:2012"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Stężenie i zawartość cyjanków wolnych i ogólnych\nZakres:\nZakres (0,0050 – 10) mg/l\nZakres (0,050 – 100) mg/kg\nStężenie cyjanków związanych (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN 12457-4:2006 | PN-EN ISO 14403-2:2012 Materialy budowlane: piasek, kruszywo, zuzel Stezenie i zawartosc cyjankow wolnych i ogolnych\nZakres:\nZakres (0,0050 – 10) mg/l\nZakres (0,050 – 100) mg/kg\nStezenie cyjankow zwiazanych (z obliczen)\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN 12457-4:2006 | PN-EN ISO 14403-2:2012","categories":["materials","construction"],"row_index":212,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration and content of free and total cyanides","parameters_en":[{"name":"Range","range":"(0,0050 – 10) mg/l"},{"name":"Range","range":"(0,050 – 100) mg/kg"},{"name":"Combined cyanide concentration (calculated)"}],"search_en":"Construction materials: sand, aggregate, slag Concentration and content of free and total cyanides Continuous flow analysis (CFA) with spectrophotometric detection Range Range Combined cyanide concentration (calculated) PN-EN 12457-4:2006 | PN-EN ISO 14403-2:2012","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(0,0050 – 10) mg/l"},{"name":"范围","range":"(0,050 – 100) mg/kg"},{"name":"络合氰化物浓度（由计算得出）"}],"search_zh":"建筑材料：砂、骨料、炉渣 连续流动分析（CFA）分光光度检测法 范围 范围 络合氰化物浓度（由计算得出） PN-EN 12457-4:2006 | PN-EN ISO 14403-2:2012","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c559d","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Stężenie fosforanów","parameters":[{"name":"Zakres","range":"(0,05 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforanów\nZakres (0,05 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 12457-4:2006 | PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Stężenie fosforanów\nZakres (0,05 – 200) mg/l\nMetoda spektrofotometryczna PN-EN 12457-4:2006 | PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010 Materialy budowlane: piasek, kruszywo, zuzel Stezenie fosforanow\nZakres (0,05 – 200) mg/l\nMetoda spektrofotometryczna PN-EN 12457-4:2006 | PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010","categories":["materials","construction"],"row_index":213,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphate concentration","parameters_en":[{"name":"Range","range":"(0,05 – 200) mg/l"}],"search_en":"Construction materials: sand, aggregate, slag Phosphate concentration Spectrophotometric method Range PN-EN 12457-4:2006 | PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(0,05 – 200) mg/l"}],"search_zh":"建筑材料：砂、骨料、炉渣 磷酸盐浓度 分光光度法 范围 PN-EN 12457-4:2006 | PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"建筑材料：砂、骨料、炉渣","methodology_zh":"磷酸盐浓度"},{"_id":"6a832b7f884ede9a1b2c559e","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,016 – 65,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,016 – 65,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 12457-4:2006 | PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010 Dokumenty odniesienia","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010 Dokumenty odniesienia"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Stężenie fosforu ogólnego\nZakres (0,016 – 65,0) mg/l\nMetoda spektrofotometryczna PN-EN 12457-4:2006 | PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010 Dokumenty odniesienia Materialy budowlane: piasek, kruszywo, zuzel Stezenie fosforu ogolnego\nZakres (0,016 – 65,0) mg/l\nMetoda spektrofotometryczna PN-EN 12457-4:2006 | PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010 Dokumenty odniesienia","categories":["materials","construction"],"row_index":214,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,016 – 65,0) mg/l"}],"search_en":"Construction materials: sand, aggregate, slag Total phosphorus concentration Spectrophotometric method Range PN-EN 12457-4:2006 | PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010 Dokumenty odniesienia","technique_en":"Spectrophotometric method","test_object_en":"Construction materials: sand, aggregate, slag","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,016 – 65,0) mg/l"}],"search_zh":"建筑材料：砂、骨料、炉渣 总磷浓度 分光光度法 范围 PN-EN 12457-4:2006 | PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010 Dokumenty odniesienia","technique_zh":"分光光度法","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c559f","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Zawartość pierwiastków","parameters":[{"name":"antymon","range":"(0,010 – 50) mg/kg"},{"name":"arsen","range":"(0,010 – 50) mg/kg"},{"name":"bar","range":"(0,050 – 1000) mg/kg"},{"name":"beryl","range":"(0,0050 – 50) mg/kg"},{"name":"bor","range":"(0,20 – 1000) mg/kg"},{"name":"chrom","range":"(0,010 – 50) mg/kg"},{"name":"cyna","range":"(0,010 – 50) mg/kg"},{"name":"cynk","range":"(0,10 – 1000) mg/kg"},{"name":"glin","range":"(0,10 – 1000) mg/kg"},{"name":"kadm","range":"(0,00050 – 50) mg/kg"},{"name":"kobalt","range":"(0,010 – 50) mg/kg"},{"name":"mangan","range":"(0,050 – 1000) mg/kg"},{"name":"magnez","range":"(5,0 – 50000) mg/kg"},{"name":"miedź","range":"(0,010 – 50) mg/kg"},{"name":"molibden","range":"(0,010 – 50) mg/kg"},{"name":"nikiel","range":"(0,010 – 50) mg/kg"},{"name":"ołów","range":"(0,010 – 50) mg/kg"},{"name":"potas","range":"(5,0 – 50000) mg/kg"},{"name":"rtęć","range":"(0,0010 – 5,0) mg/kg"},{"name":"selen","range":"(0,010 – 50) mg/kg"},{"name":"sód","range":"(5,0 – 50000) mg/kg"},{"name":"srebro","range":"(0,010 – 50) mg/kg"},{"name":"stront","range":"(0,050 – 1000) mg/kg"},{"name":"wanad","range":"(0,010 – 50) mg/kg"},{"name":"tal","range":"(0,0025 – 50) mg/kg"},{"name":"wapń","range":"(5,0 – 50000) mg/kg"},{"name":"żelazo","range":"(0,10 – 5000) mg/kg"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nantymon (0,010 – 50) mg/kg\narsen (0,010 – 50) mg/kg\nbar (0,050 – 1000) mg/kg\nberyl (0,0050 – 50) mg/kg\nbor (0,20 – 1000) mg/kg\nchrom (0,010 – 50) mg/kg\ncyna (0,010 – 50) mg/kg\ncynk (0,10 – 1000) mg/kg\nglin (0,10 – 1000) mg/kg\nkadm (0,00050 – 50) mg/kg\nkobalt (0,010 – 50) mg/kg\nmangan (0,050 – 1000) mg/kg\nmagnez (5,0 – 50000) mg/kg\nmiedź (0,010 – 50) mg/kg\nmolibden (0,010 – 50) mg/kg\nnikiel (0,010 – 50) mg/kg\nołów (0,010 – 50) mg/kg\npotas (5,0 – 50000) mg/kg\nrtęć (0,0010 – 5,0) mg/kg\nselen (0,010 – 50) mg/kg\nsód (5,0 – 50000) mg/kg\nsrebro (0,010 – 50) mg/kg\nstront (0,050 – 1000) mg/kg\nwanad (0,010 – 50) mg/kg\ntal (0,0025 – 50) mg/kg\nwapń (5,0 – 50000) mg/kg\nżelazo (0,10 – 5000) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN 12457-4:2006 | PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 17294-2:2024-04"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Zawartość pierwiastków\nZakres:\nantymon (0,010 – 50) mg/kg\narsen (0,010 – 50) mg/kg\nbar (0,050 – 1000) mg/kg\nberyl (0,0050 – 50) mg/kg\nbor (0,20 – 1000) mg/kg\nchrom (0,010 – 50) mg/kg\ncyna (0,010 – 50) mg/kg\ncynk (0,10 – 1000) mg/kg\nglin (0,10 – 1000) mg/kg\nkadm (0,00050 – 50) mg/kg\nkobalt (0,010 – 50) mg/kg\nmangan (0,050 – 1000) mg/kg\nmagnez (5,0 – 50000) mg/kg\nmiedź (0,010 – 50) mg/kg\nmolibden (0,010 – 50) mg/kg\nnikiel (0,010 – 50) mg/kg\nołów (0,010 – 50) mg/kg\npotas (5,0 – 50000) mg/kg\nrtęć (0,0010 – 5,0) mg/kg\nselen (0,010 – 50) mg/kg\nsód (5,0 – 50000) mg/kg\nsrebro (0,010 – 50) mg/kg\nstront (0,050 – 1000) mg/kg\nwanad (0,010 – 50) mg/kg\ntal (0,0025 – 50) mg/kg\nwapń (5,0 – 50000) mg/kg\nżelazo (0,10 – 5000) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN 12457-4:2006 | PN-EN ISO 17294-2:2024-04 Materialy budowlane: piasek, kruszywo, zuzel Zawartosc pierwiastkow\nZakres:\nantymon (0,010 – 50) mg/kg\narsen (0,010 – 50) mg/kg\nbar (0,050 – 1000) mg/kg\nberyl (0,0050 – 50) mg/kg\nbor (0,20 – 1000) mg/kg\nchrom (0,010 – 50) mg/kg\ncyna (0,010 – 50) mg/kg\ncynk (0,10 – 1000) mg/kg\nglin (0,10 – 1000) mg/kg\nkadm (0,00050 – 50) mg/kg\nkobalt (0,010 – 50) mg/kg\nmangan (0,050 – 1000) mg/kg\nmagnez (5,0 – 50000) mg/kg\nmiedz (0,010 – 50) mg/kg\nmolibden (0,010 – 50) mg/kg\nnikiel (0,010 – 50) mg/kg\nolow (0,010 – 50) mg/kg\npotas (5,0 – 50000) mg/kg\nrtec (0,0010 – 5,0) mg/kg\nselen (0,010 – 50) mg/kg\nsod (5,0 – 50000) mg/kg\nsrebro (0,010 – 50) mg/kg\nstront (0,050 – 1000) mg/kg\nwanad (0,010 – 50) mg/kg\ntal (0,0025 – 50) mg/kg\nwapn (5,0 – 50000) mg/kg\nzelazo (0,10 – 5000) mg/kg\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN 12457-4:2006 | PN-EN ISO 17294-2:2024-04","categories":["materials","construction"],"row_index":215,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","parameters_en":[{"name":"antimony","range":"(0,010 – 50) mg/kg"},{"name":"arsenic","range":"(0,010 – 50) mg/kg"},{"name":"barium","range":"(0,050 – 1000) mg/kg"},{"name":"beryllium","range":"(0,0050 – 50) mg/kg"},{"name":"boron","range":"(0,20 – 1000) mg/kg"},{"name":"chromium","range":"(0,010 – 50) mg/kg"},{"name":"tin","range":"(0,010 – 50) mg/kg"},{"name":"zinc","range":"(0,10 – 1000) mg/kg"},{"name":"aluminium","range":"(0,10 – 1000) mg/kg"},{"name":"cadmium","range":"(0,00050 – 50) mg/kg"},{"name":"cobalt","range":"(0,010 – 50) mg/kg"},{"name":"manganese","range":"(0,050 – 1000) mg/kg"},{"name":"magnesium","range":"(5,0 – 50000) mg/kg"},{"name":"copper","range":"(0,010 – 50) mg/kg"},{"name":"molybdenum","range":"(0,010 – 50) mg/kg"},{"name":"nickel","range":"(0,010 – 50) mg/kg"},{"name":"lead","range":"(0,010 – 50) mg/kg"},{"name":"potassium","range":"(5,0 – 50000) mg/kg"},{"name":"mercury","range":"(0,0010 – 5,0) mg/kg"},{"name":"selenium","range":"(0,010 – 50) mg/kg"},{"name":"sodium","range":"(5,0 – 50000) mg/kg"},{"name":"silver","range":"(0,010 – 50) mg/kg"},{"name":"strontium","range":"(0,050 – 1000) mg/kg"},{"name":"vanadium","range":"(0,010 – 50) mg/kg"},{"name":"thallium","range":"(0,0025 – 50) mg/kg"},{"name":"calcium","range":"(5,0 – 50000) mg/kg"},{"name":"iron","range":"(0,10 – 5000) mg/kg"}],"search_en":"Construction materials: sand, aggregate, slag Element content Inductively coupled plasma mass spectrometry (ICP-MS) antimony arsenic barium beryllium boron chromium tin zinc aluminium cadmium cobalt manganese magnesium copper molybdenum nickel lead potassium mercury selenium sodium silver strontium vanadium thallium calcium iron PN-EN 12457-4:2006 | PN-EN ISO 17294-2:2024-04","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Construction materials: sand, aggregate, slag","methodology_zh":"元素含量","parameters_zh":[{"name":"锑","range":"(0,010 – 50) mg/kg"},{"name":"砷","range":"(0,010 – 50) mg/kg"},{"name":"钡","range":"(0,050 – 1000) mg/kg"},{"name":"铍","range":"(0,0050 – 50) mg/kg"},{"name":"硼","range":"(0,20 – 1000) mg/kg"},{"name":"铬","range":"(0,010 – 50) mg/kg"},{"name":"锡","range":"(0,010 – 50) mg/kg"},{"name":"锌","range":"(0,10 – 1000) mg/kg"},{"name":"铝","range":"(0,10 – 1000) mg/kg"},{"name":"镉","range":"(0,00050 – 50) mg/kg"},{"name":"钴","range":"(0,010 – 50) mg/kg"},{"name":"锰","range":"(0,050 – 1000) mg/kg"},{"name":"镁","range":"(5,0 – 50000) mg/kg"},{"name":"铜","range":"(0,010 – 50) mg/kg"},{"name":"钼","range":"(0,010 – 50) mg/kg"},{"name":"镍","range":"(0,010 – 50) mg/kg"},{"name":"铅","range":"(0,010 – 50) mg/kg"},{"name":"钾","range":"(5,0 – 50000) mg/kg"},{"name":"汞","range":"(0,0010 – 5,0) mg/kg"},{"name":"硒","range":"(0,010 – 50) mg/kg"},{"name":"钠","range":"(5,0 – 50000) mg/kg"},{"name":"银","range":"(0,010 – 50) mg/kg"},{"name":"锶","range":"(0,050 – 1000) mg/kg"},{"name":"钒","range":"(0,010 – 50) mg/kg"},{"name":"铊","range":"(0,0025 – 50) mg/kg"},{"name":"钙","range":"(5,0 – 50000) mg/kg"},{"name":"铁","range":"(0,10 – 5000) mg/kg"}],"search_zh":"建筑材料：砂、骨料、炉渣 元素含量 电感耦合等离子体质谱法（ICP-MS） 锑 砷 钡 铍 硼 铬 锡 锌 铝 镉 钴 锰 镁 铜 钼 镍 铅 钾 汞 硒 钠 银 锶 钒 铊 钙 铁 PN-EN 12457-4:2006 | PN-EN ISO 17294-2:2024-04","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c55a0","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Stężenie rozpuszczonego węgla","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie rozpuszczonego węgla","reference":"PN-EN 12457-4:2006","norm_bases":["PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Stężenie rozpuszczonego węgla PN-EN 12457-4:2006 Materialy budowlane: piasek, kruszywo, zuzel Stezenie rozpuszczonego wegla PN-EN 12457-4:2006","categories":["materials","construction"],"row_index":216,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved carbon concentration","search_en":"Construction materials: sand, aggregate, slag Dissolved carbon concentration PN-EN 12457-4:2006","test_object_en":"Construction materials: sand, aggregate, slag","search_zh":"建筑材料：砂、骨料、炉渣 PN-EN 12457-4:2006","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c55a1","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"organicznego (DOC)","parameters":[{"name":"Zakres","range":"(1,50 – 2000) mg/l"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"organicznego (DOC)\nZakres (1,50 – 2000) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel organicznego (DOC)\nZakres (1,50 – 2000) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999 Materialy budowlane: piasek, kruszywo, zuzel organicznego (DOC)\nZakres (1,50 – 2000) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999","categories":["materials","construction"],"row_index":217,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"organicznego (DOC)","parameters_en":[{"name":"Range","range":"(1,50 – 2000) mg/l"}],"search_en":"Construction materials: sand, aggregate, slag organicznego (DOC) Spectrometry method in the infrared range IR Range PN-EN 1484:1999","technique_en":"Spectrometry method in the infrared range IR","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(1,50 – 2000) mg/l"}],"search_zh":"建筑材料：砂、骨料、炉渣 红外光谱法 IR 范围 PN-EN 1484:1999","test_object_zh":"建筑材料：砂、骨料、炉渣","technique_zh":"红外光谱法 IR"},{"_id":"6a832b7f884ede9a1b2c55a2","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Stężenie rtęci","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie rtęci","reference":"PN-EN 12457-4:2006","norm_bases":["PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Stężenie rtęci PN-EN 12457-4:2006 Materialy budowlane: piasek, kruszywo, zuzel Stezenie rteci PN-EN 12457-4:2006","categories":["materials","construction"],"row_index":218,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","search_en":"Construction materials: sand, aggregate, slag Mercury concentration PN-EN 12457-4:2006","test_object_en":"Construction materials: sand, aggregate, slag","methodology_zh":"汞浓度","search_zh":"建筑材料：砂、骨料、炉渣 汞浓度 PN-EN 12457-4:2006","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c55a3","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"","parameters":[{"name":"Zakres","range":"(0,0005 – 0,50) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zakres (0,0005 – 0,50) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012 +Ap1:2016-07","norm_bases":["PN-EN ISO 12846:2012 +Ap1:2016-07"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Zakres (0,0005 – 0,50) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 +Ap1:2016-07 Materialy budowlane: piasek, kruszywo, zuzel Zakres (0,0005 – 0,50) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 +Ap1:2016-07","categories":["materials","construction"],"row_index":219,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,0005 – 0,50) mg/l"}],"search_en":"Construction materials: sand, aggregate, slag Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN ISO 12846:2012 +Ap1:2016-07","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(0,0005 – 0,50) mg/l"}],"search_zh":"建筑材料：砂、骨料、炉渣 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN ISO 12846:2012 +Ap1:2016-07","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c55a4","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Stężenie siarkowodoru i siarczków","parameters":[{"name":"Zakres","range":"(0,2 – 10,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie siarkowodoru i siarczków\nZakres (0,2 – 10,0) mg/l\nMetoda miareczkowa","reference":"PN-EN 12457-4:2006 | PN-74/C-04566/03","norm_bases":["PN-EN 12457-4:2006","PN-74/C-04566/03"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Stężenie siarkowodoru i siarczków\nZakres (0,2 – 10,0) mg/l\nMetoda miareczkowa PN-EN 12457-4:2006 | PN-74/C-04566/03 Materialy budowlane: piasek, kruszywo, zuzel Stezenie siarkowodoru i siarczkow\nZakres (0,2 – 10,0) mg/l\nMetoda miareczkowa PN-EN 12457-4:2006 | PN-74/C-04566/03","categories":["materials","construction"],"row_index":220,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen sulfide and sulfide concentration","parameters_en":[{"name":"Range","range":"(0,2 – 10,0) mg/l"}],"search_en":"Construction materials: sand, aggregate, slag Hydrogen sulfide and sulfide concentration Titrimetric method Range PN-EN 12457-4:2006 | PN-74/C-04566/03","technique_en":"Titrimetric method","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(0,2 – 10,0) mg/l"}],"search_zh":"建筑材料：砂、骨料、炉渣 硫化氢与硫化物浓度 滴定法 范围 PN-EN 12457-4:2006 | PN-74/C-04566/03","technique_zh":"滴定法","test_object_zh":"建筑材料：砂、骨料、炉渣","methodology_zh":"硫化氢与硫化物浓度"},{"_id":"6a832b7f884ede9a1b2c55a5","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Substancje rozpuszczone ogólne","parameters":[{"name":"Zakres","range":"(10,0 – 50000) mg/l"},{"name":"Zawartość stałych związków rozpuszczonych -TDS (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone ogólne\nZakres:\nZakres (10,0 – 50000) mg/l\nZawartość stałych związków rozpuszczonych -TDS (z obliczeń)\nMetoda wagowa","reference":"PN-EN 12457-4:2006 | PN-EN 15216:2022-03","norm_bases":["PN-EN 12457-4:2006","PN-EN 15216:2022-03"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Substancje rozpuszczone ogólne\nZakres:\nZakres (10,0 – 50000) mg/l\nZawartość stałych związków rozpuszczonych -TDS (z obliczeń)\nMetoda wagowa PN-EN 12457-4:2006 | PN-EN 15216:2022-03 Materialy budowlane: piasek, kruszywo, zuzel Substancje rozpuszczone ogolne\nZakres:\nZakres (10,0 – 50000) mg/l\nZawartosc stalych zwiazkow rozpuszczonych -TDS (z obliczen)\nMetoda wagowa PN-EN 12457-4:2006 | PN-EN 15216:2022-03","categories":["materials","construction"],"row_index":221,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids","parameters_en":[{"name":"Range","range":"(10,0 – 50000) mg/l"},{"name":"Total dissolved solids content -TDS (calculated)"}],"search_en":"Construction materials: sand, aggregate, slag Total dissolved solids Gravimetric method Range Total dissolved solids content -TDS (calculated) PN-EN 12457-4:2006 | PN-EN 15216:2022-03","technique_en":"Gravimetric method","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(10,0 – 50000) mg/l"},{"name":"Zawartość stałych związków rozpuszczonych -TDS (z obliczeń)"}],"search_zh":"建筑材料：砂、骨料、炉渣 重量法 范围 PN-EN 12457-4:2006 | PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c55a6","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Zasadowość ogólna (zdolność do neutralizacji kwasów ANC)","parameters":[{"name":"Zakres","range":"(5,0 – 5000) mg/l CaCO3"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zasadowość ogólna (zdolność do neutralizacji kwasów ANC)\nZakres (5,0 – 5000) mg/l CaCO3\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN 12457-4:2006 | PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Zasadowość ogólna (zdolność do neutralizacji kwasów ANC)\nZakres (5,0 – 5000) mg/l CaCO3\nMetoda miareczkowania potencjometrycznego PN-EN 12457-4:2006 | PN-EN ISO 9963-1:2001+Ap1:2004 Materialy budowlane: piasek, kruszywo, zuzel Zasadowosc ogolna (zdolnosc do neutralizacji kwasow ANC)\nZakres (5,0 – 5000) mg/l CaCO3\nMetoda miareczkowania potencjometrycznego PN-EN 12457-4:2006 | PN-EN ISO 9963-1:2001+Ap1:2004","categories":["materials","construction"],"row_index":222,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total alkalinity (acid neutralisation capacity ANC)","parameters_en":[{"name":"Range","range":"(5,0 – 5000) mg/l CaCO3"}],"search_en":"Construction materials: sand, aggregate, slag Total alkalinity (acid neutralisation capacity ANC) Potentiometric titration method Range PN-EN 12457-4:2006 | PN-EN ISO 9963-1:2001+Ap1:2004","technique_en":"Potentiometric titration method","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(5,0 – 5000) mg/l CaCO3"}],"search_zh":"建筑材料：砂、骨料、炉渣 总碱度（酸中和能力 ANC） 电位滴定法 范围 PN-EN 12457-4:2006 | PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"电位滴定法","test_object_zh":"建筑材料：砂、骨料、炉渣","methodology_zh":"总碱度（酸中和能力 ANC）"},{"_id":"6a832b7f884ede9a1b2c55a7","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Straty przy prażeniu (LOI) / substancje organiczne","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu (LOI) / substancje organiczne\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Straty przy prażeniu (LOI) / substancje organiczne\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15935:2022-01 Materialy budowlane: piasek, kruszywo, zuzel Straty przy prazeniu (LOI) / substancje organiczne\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["materials","construction"],"row_index":223,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition (LOI) / organic matter","parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"search_en":"Construction materials: sand, aggregate, slag Loss on ignition (LOI) / organic matter Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"建筑材料：砂、骨料、炉渣 烧失量（LOI）/ 有机物质 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"建筑材料：砂、骨料、炉渣","methodology_zh":"烧失量（LOI）/ 有机物质"},{"_id":"6a832b7f884ede9a1b2c55a8","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,002 – 8,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres (0,002 – 8,00) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Zawartość azotu Kjeldahla\nZakres (0,002 – 8,00) %\nMetoda miareczkowa PN-EN 13342:2002 Materialy budowlane: piasek, kruszywo, zuzel Zawartosc azotu Kjeldahla\nZakres (0,002 – 8,00) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["materials","construction"],"row_index":224,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,002 – 8,00) %"}],"search_en":"Construction materials: sand, aggregate, slag Kjeldahl nitrogen content Titrimetric method Range PN-EN 13342:2002","technique_en":"Titrimetric method","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(0,002 – 8,00) %"}],"search_zh":"建筑材料：砂、骨料、炉渣 凯氏氮含量 滴定法 范围 PN-EN 13342:2002","technique_zh":"滴定法","methodology_zh":"凯氏氮含量","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c55a9","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,005 – 10,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (0,005 – 10,0) %\nMetoda miareczkowa","reference":"PN-75/C-04576/15","norm_bases":["PN-75/C-04576/15"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Zawartość azotu amonowego\nZakres (0,005 – 10,0) %\nMetoda miareczkowa PN-75/C-04576/15 Materialy budowlane: piasek, kruszywo, zuzel Zawartosc azotu amonowego\nZakres (0,005 – 10,0) %\nMetoda miareczkowa PN-75/C-04576/15","categories":["materials","construction"],"row_index":225,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,005 – 10,0) %"}],"search_en":"Construction materials: sand, aggregate, slag Ammonium nitrogen content Titrimetric method Range PN-75/C-04576/15","technique_en":"Titrimetric method","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(0,005 – 10,0) %"}],"search_zh":"建筑材料：砂、骨料、炉渣 氨氮含量 滴定法 范围 PN-75/C-04576/15","technique_zh":"滴定法","methodology_zh":"氨氮含量","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c55aa","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Zawartość benzyny (C6-C12)","parameters":[{"name":"Zakres","range":"(1,0 – 750) mg/kg"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Zawartość benzyny (C6-C12)\nZakres (1,0 – 750) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PB/I/3/G:10.04.2017","norm_bases":["PB/I/3/G:10.04.2017"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Zawartość benzyny (C6-C12)\nZakres (1,0 – 750) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID) PB/I/3/G:10.04.2017 Materialy budowlane: piasek, kruszywo, zuzel Zawartosc benzyny (C6-C12)\nZakres (1,0 – 750) mg/kg\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej z detekcja plomieniowo-jonizacyjna (HS-GC-FID) PB/I/3/G:10.04.2017","categories":["materials","construction"],"row_index":226,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Petrol content (C6-C12)","parameters_en":[{"name":"Range","range":"(1,0 – 750) mg/kg"}],"search_en":"Construction materials: sand, aggregate, slag Petrol content (C6-C12) Headspace gas chromatography with flame ionization detection (HS-GC-FID) Range PB/I/3/G:10.04.2017","technique_en":"Headspace gas chromatography with flame ionization detection (HS-GC-FID)","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(1,0 – 750) mg/kg"}],"search_zh":"建筑材料：砂、骨料、炉渣 汽油（C6-C12）含量 顶空气相色谱-火焰离子化检测法（HS-GC-FID） 范围 PB/I/3/G:10.04.2017","test_object_zh":"建筑材料：砂、骨料、炉渣","technique_zh":"顶空气相色谱-火焰离子化检测法（HS-GC-FID）","methodology_zh":"汽油（C6-C12）含量"},{"_id":"6a832b7f884ede9a1b2c55ab","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Zawartość cyjanków wolnych i ogólnych","parameters":[{"name":"Zakres","range":"(0,50 – 100) mg/kg"},{"name":"Zawartość cyjanków związanych (z obliczeń)"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość cyjanków wolnych i ogólnych\nZakres:\nZakres (0,50 – 100) mg/kg\nZawartość cyjanków związanych (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 17380:2013-08","norm_bases":["PN-EN ISO 17380:2013-08"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Zawartość cyjanków wolnych i ogólnych\nZakres:\nZakres (0,50 – 100) mg/kg\nZawartość cyjanków związanych (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 17380:2013-08 Materialy budowlane: piasek, kruszywo, zuzel Zawartosc cyjankow wolnych i ogolnych\nZakres:\nZakres (0,50 – 100) mg/kg\nZawartosc cyjankow zwiazanych (z obliczen)\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 17380:2013-08","categories":["materials","construction"],"row_index":227,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free and total cyanide content","parameters_en":[{"name":"Range","range":"(0,50 – 100) mg/kg"},{"name":"Combined cyanide content (calculated)"}],"search_en":"Construction materials: sand, aggregate, slag Free and total cyanide content Continuous flow analysis (CFA) with spectrophotometric detection Range Combined cyanide content (calculated) PN-EN ISO 17380:2013-08","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(0,50 – 100) mg/kg"},{"name":"络合氰化物含量（由计算得出）"}],"search_zh":"建筑材料：砂、骨料、炉渣 游离氰化物与总氰化物含量 连续流动分析（CFA）分光光度检测法 范围 络合氰化物含量（由计算得出） PN-EN ISO 17380:2013-08","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"建筑材料：砂、骨料、炉渣","methodology_zh":"游离氰化物与总氰化物含量"},{"_id":"6a832b7f884ede9a1b2c55ac","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Zawartość fenoli","parameters":[{"name":"Zakres","range":"(0,05 – 500) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fenoli\nZakres (0,05 – 500) mg/kg\nMetoda spektrofotometryczna","reference":"PB/FCH/33/D:10.04.2017","norm_bases":["PB/FCH/33/D:10.04.2017"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Zawartość fenoli\nZakres (0,05 – 500) mg/kg\nMetoda spektrofotometryczna PB/FCH/33/D:10.04.2017 Materialy budowlane: piasek, kruszywo, zuzel Zawartosc fenoli\nZakres (0,05 – 500) mg/kg\nMetoda spektrofotometryczna PB/FCH/33/D:10.04.2017","categories":["materials","construction"],"row_index":228,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol content","parameters_en":[{"name":"Range","range":"(0,05 – 500) mg/kg"}],"search_en":"Construction materials: sand, aggregate, slag Phenol content Spectrophotometric method Range PB/FCH/33/D:10.04.2017","technique_en":"Spectrophotometric method","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(0,05 – 500) mg/kg"}],"search_zh":"建筑材料：砂、骨料、炉渣 酚类含量 分光光度法 范围 PB/FCH/33/D:10.04.2017","technique_zh":"分光光度法","test_object_zh":"建筑材料：砂、骨料、炉渣","methodology_zh":"酚类含量"},{"_id":"6a832b7f884ede9a1b2c55ad","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Zawartość lotnych węglowodorów aromatycznych (BTX)","parameters":[{"name":"benzen","range":"(0,020 – 15) mg/kg"},{"name":"etylobenzen","range":"(0,020 – 15) mg/kg"},{"name":"toluen","range":"(0,020 – 15) mg/kg"},{"name":"suma ksylenów","range":"(0,020 – 45) mg/kg"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Zawartość lotnych węglowodorów aromatycznych (BTX)\nZakres:\nbenzen (0,020 – 15) mg/kg\netylobenzen (0,020 – 15) mg/kg\ntoluen (0,020 – 15) mg/kg\nsuma ksylenów (0,020 – 45) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PB/I/3/G:10.04.2017","norm_bases":["PB/I/3/G:10.04.2017"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Zawartość lotnych węglowodorów aromatycznych (BTX)\nZakres:\nbenzen (0,020 – 15) mg/kg\netylobenzen (0,020 – 15) mg/kg\ntoluen (0,020 – 15) mg/kg\nsuma ksylenów (0,020 – 45) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID) PB/I/3/G:10.04.2017 Materialy budowlane: piasek, kruszywo, zuzel Zawartosc lotnych weglowodorow aromatycznych (BTX)\nZakres:\nbenzen (0,020 – 15) mg/kg\netylobenzen (0,020 – 15) mg/kg\ntoluen (0,020 – 15) mg/kg\nsuma ksylenow (0,020 – 45) mg/kg\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej z detekcja plomieniowo-jonizacyjna (HS-GC-FID) PB/I/3/G:10.04.2017","categories":["materials","construction"],"row_index":229,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of volatile aromatic hydrocarbons (BTX)","parameters_en":[{"name":"benzene","range":"(0,020 – 15) mg/kg"},{"name":"ethylbenzene","range":"(0,020 – 15) mg/kg"},{"name":"toluene","range":"(0,020 – 15) mg/kg"},{"name":"sum of xylenes","range":"(0,020 – 45) mg/kg"}],"search_en":"Construction materials: sand, aggregate, slag Content of volatile aromatic hydrocarbons (BTX) Headspace gas chromatography with flame ionization detection (HS-GC-FID) benzene ethylbenzene toluene sum of xylenes PB/I/3/G:10.04.2017","technique_en":"Headspace gas chromatography with flame ionization detection (HS-GC-FID)","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"苯","range":"(0,020 – 15) mg/kg"},{"name":"乙苯","range":"(0,020 – 15) mg/kg"},{"name":"甲苯","range":"(0,020 – 15) mg/kg"},{"name":"二甲苯总量","range":"(0,020 – 45) mg/kg"}],"search_zh":"建筑材料：砂、骨料、炉渣 顶空气相色谱-火焰离子化检测法（HS-GC-FID） 苯 乙苯 甲苯 二甲苯总量 PB/I/3/G:10.04.2017","test_object_zh":"建筑材料：砂、骨料、炉渣","technique_zh":"顶空气相色谱-火焰离子化检测法（HS-GC-FID）"},{"_id":"6a832b7f884ede9a1b2c55ae","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Suma BTX (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma BTX (z obliczeń)","reference":"PB/I/3/G:10.04.2017","norm_bases":["PB/I/3/G:10.04.2017"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Suma BTX (z obliczeń) PB/I/3/G:10.04.2017 Materialy budowlane: piasek, kruszywo, zuzel Suma BTX (z obliczen) PB/I/3/G:10.04.2017","categories":["materials","construction"],"row_index":230,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of BTX (calculated)","search_en":"Construction materials: sand, aggregate, slag Sum of BTX (calculated) PB/I/3/G:10.04.2017","test_object_en":"Construction materials: sand, aggregate, slag","search_zh":"建筑材料：砂、骨料、炉渣 BTX 总量（由计算得出） PB/I/3/G:10.04.2017","test_object_zh":"建筑材料：砂、骨料、炉渣","methodology_zh":"BTX 总量（由计算得出）"},{"_id":"6a832b7f884ede9a1b2c55af","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Zawartość ogólnego węgla organicznego (TOC)","parameters":[{"name":"Zakres","range":"(0,50 – 60) %"},{"name":"Zakres","range":"(5000 – 600000) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość ogólnego węgla organicznego (TOC)\nZakres:\nZakres (0,50 – 60) %\nZakres (5000 – 600000) mg/kg\nMetoda miareczkowa","reference":"PB/FCH/17/C:10.04.2017","norm_bases":["PB/FCH/17/C:10.04.2017"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Zawartość ogólnego węgla organicznego (TOC)\nZakres:\nZakres (0,50 – 60) %\nZakres (5000 – 600000) mg/kg\nMetoda miareczkowa PB/FCH/17/C:10.04.2017 Materialy budowlane: piasek, kruszywo, zuzel Zawartosc ogolnego wegla organicznego (TOC)\nZakres:\nZakres (0,50 – 60) %\nZakres (5000 – 600000) mg/kg\nMetoda miareczkowa PB/FCH/17/C:10.04.2017","categories":["materials","construction"],"row_index":231,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon (TOC) content","parameters_en":[{"name":"Range","range":"(0,50 – 60) %"},{"name":"Range","range":"(5000 – 600000) mg/kg"}],"search_en":"Construction materials: sand, aggregate, slag Total organic carbon (TOC) content Titrimetric method Range Range PB/FCH/17/C:10.04.2017","technique_en":"Titrimetric method","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(0,50 – 60) %"},{"name":"范围","range":"(5000 – 600000) mg/kg"}],"search_zh":"建筑材料：砂、骨料、炉渣 总有机碳（TOC）含量 滴定法 范围 范围 PB/FCH/17/C:10.04.2017","technique_zh":"滴定法","test_object_zh":"建筑材料：砂、骨料、炉渣","methodology_zh":"总有机碳（TOC）含量"},{"_id":"6a832b7f884ede9a1b2c55b0","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Zawartość ogólnego węgla organicznego (TOC)","parameters":[{"name":"Zakres","range":"(0,10 – 60) %"},{"name":"Zakres","range":"(1000 – 600000) mg/kg"}],"technique":"Metoda wysoko temperaturowego spalania z detekcją IR","techniques":["Metoda wysoko temperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość ogólnego węgla organicznego (TOC)\nZakres:\nZakres (0,10 – 60) %\nZakres (1000 – 600000) mg/kg\nMetoda wysoko temperaturowego spalania z detekcją IR","reference":"PN EN 15936:2022-07","norm_bases":["PN EN 15936:2022-07"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Zawartość ogólnego węgla organicznego (TOC)\nZakres:\nZakres (0,10 – 60) %\nZakres (1000 – 600000) mg/kg\nMetoda wysoko temperaturowego spalania z detekcją IR PN EN 15936:2022-07 Materialy budowlane: piasek, kruszywo, zuzel Zawartosc ogolnego wegla organicznego (TOC)\nZakres:\nZakres (0,10 – 60) %\nZakres (1000 – 600000) mg/kg\nMetoda wysoko temperaturowego spalania z detekcja IR PN EN 15936:2022-07","categories":["materials","construction"],"row_index":232,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon (TOC) content","parameters_en":[{"name":"Range","range":"(0,10 – 60) %"},{"name":"Range","range":"(1000 – 600000) mg/kg"}],"search_en":"Construction materials: sand, aggregate, slag Total organic carbon (TOC) content High-temperature combustion with IR detection Range Range PN EN 15936:2022-07","technique_en":"High-temperature combustion with IR detection","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(0,10 – 60) %"},{"name":"范围","range":"(1000 – 600000) mg/kg"}],"search_zh":"建筑材料：砂、骨料、炉渣 总有机碳（TOC）含量 高温燃烧-红外检测法 范围 范围 PN EN 15936:2022-07","test_object_zh":"建筑材料：砂、骨料、炉渣","methodology_zh":"总有机碳（TOC）含量","technique_zh":"高温燃烧-红外检测法"},{"_id":"6a832b7f884ede9a1b2c55b1","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Zawartość oleju mineralnego","parameters":[{"name":"Zakres","range":"(5,0 – 5000) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość oleju mineralnego\nZakres (5,0 – 5000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 14039:2008","norm_bases":["PN-EN 14039:2008"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Zawartość oleju mineralnego\nZakres (5,0 – 5000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 14039:2008 Materialy budowlane: piasek, kruszywo, zuzel Zawartosc oleju mineralnego\nZakres (5,0 – 5000) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 14039:2008","categories":["materials","construction","petro"],"row_index":233,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil content","parameters_en":[{"name":"Range","range":"(5,0 – 5000) mg/kg"}],"search_en":"Construction materials: sand, aggregate, slag Mineral oil content Gas chromatography with flame ionization detection (GC-FID) Range PN-EN 14039:2008","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(5,0 – 5000) mg/kg"}],"search_zh":"建筑材料：砂、骨料、炉渣 矿物油含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN 14039:2008","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"建筑材料：砂、骨料、炉渣","methodology_zh":"矿物油含量"},{"_id":"6a832b7f884ede9a1b2c55b2","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Zawartość pierwiastków","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość pierwiastków","reference":"PN-EN 13657:2006","norm_bases":["PN-EN 13657:2006"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Zawartość pierwiastków PN-EN 13657:2006 Materialy budowlane: piasek, kruszywo, zuzel Zawartosc pierwiastkow PN-EN 13657:2006","categories":["materials","construction"],"row_index":234,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","search_en":"Construction materials: sand, aggregate, slag Element content PN-EN 13657:2006","test_object_en":"Construction materials: sand, aggregate, slag","methodology_zh":"元素含量","search_zh":"建筑材料：砂、骨料、炉渣 元素含量 PN-EN 13657:2006","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c55b3","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"","parameters":[{"name":"antymon","range":"(5,00 – 1000) mg/kg"},{"name":"arsen","range":"(5,00 – 1000) mg/kg"},{"name":"bar","range":"(0,10 – 1000) mg/kg"},{"name":"beryl","range":"(0,10 – 200) mg/kg"},{"name":"bizmut","range":"(1,00 – 100) mg/kg"},{"name":"bor","range":"(1,50 – 500) mg/kg"},{"name":"chrom","range":"(0,30 – 1000) mg/kg"},{"name":"cyna","range":"(5,00 – 1000) mg/kg"},{"name":"cynk","range":"(0,50 – 10000) mg/kg"},{"name":"fosfor","range":"(5,00 – 100000) mg/kg"},{"name":"glin","range":"(1,00 – 1000) mg/kg"},{"name":"kadm","range":"(0,050 – 200) mg/kg"},{"name":"krzem","range":"(5,00 – 1000) mg/kg"},{"name":"kobalt","range":"(0,20 – 200) mg/kg"},{"name":"magnez","range":"(0,70 – 25000) mg/kg"},{"name":"mangan","range":"(0,10 – 500) mg/kg"},{"name":"miedź","range":"(0,40 – 5000) mg/kg"},{"name":"molibden","range":"(0,40 – 100) mg/kg"},{"name":"nikiel","range":"(0,40 – 1000) mg/kg"},{"name":"ołów","range":"(1,00 – 3000) mg/kg"},{"name":"potas","range":"(100 – 10000) mg/kg"},{"name":"sód","range":"(100 – 50000) mg/kg"},{"name":"srebro","range":"(0,10 – 100) mg/kg"},{"name":"stront","range":"(0,30 – 500) mg/kg"},{"name":"tal","range":"(5,00 – 100) mg/kg"},{"name":"tytan","range":"(0,10 – 100) mg/kg"},{"name":"wanad","range":"(0,50 – 500) mg/kg"},{"name":"wapń","range":"(1,00 – 200000) mg/kg"},{"name":"żelazo","range":"(0,40 – 15000) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zakres:\nantymon (5,00 – 1000) mg/kg\narsen (5,00 – 1000) mg/kg\nbar (0,10 – 1000) mg/kg\nberyl (0,10 – 200) mg/kg\nbizmut (1,00 – 100) mg/kg\nbor (1,50 – 500) mg/kg\nchrom (0,30 – 1000) mg/kg\ncyna (5,00 – 1000) mg/kg\ncynk (0,50 – 10000) mg/kg\nfosfor (5,00 – 100000) mg/kg\nglin (1,00 – 1000) mg/kg\nkadm (0,050 – 200) mg/kg\nkrzem (5,00 – 1000) mg/kg\nkobalt (0,20 – 200) mg/kg\nmagnez (0,70 – 25000) mg/kg\nmangan (0,10 – 500) mg/kg\nmiedź (0,40 – 5000) mg/kg\nmolibden (0,40 – 100) mg/kg\nnikiel (0,40 – 1000) mg/kg\nołów (1,00 – 3000) mg/kg\npotas (100 – 10000) mg/kg\nsód (100 – 50000) mg/kg\nsrebro (0,10 – 100) mg/kg\nstront (0,30 – 500) mg/kg\ntal (5,00 – 100) mg/kg\ntytan (0,10 – 100) mg/kg\nwanad (0,50 – 500) mg/kg\nwapń (1,00 – 200000) mg/kg\nżelazo (0,40 – 15000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Zakres:\nantymon (5,00 – 1000) mg/kg\narsen (5,00 – 1000) mg/kg\nbar (0,10 – 1000) mg/kg\nberyl (0,10 – 200) mg/kg\nbizmut (1,00 – 100) mg/kg\nbor (1,50 – 500) mg/kg\nchrom (0,30 – 1000) mg/kg\ncyna (5,00 – 1000) mg/kg\ncynk (0,50 – 10000) mg/kg\nfosfor (5,00 – 100000) mg/kg\nglin (1,00 – 1000) mg/kg\nkadm (0,050 – 200) mg/kg\nkrzem (5,00 – 1000) mg/kg\nkobalt (0,20 – 200) mg/kg\nmagnez (0,70 – 25000) mg/kg\nmangan (0,10 – 500) mg/kg\nmiedź (0,40 – 5000) mg/kg\nmolibden (0,40 – 100) mg/kg\nnikiel (0,40 – 1000) mg/kg\nołów (1,00 – 3000) mg/kg\npotas (100 – 10000) mg/kg\nsód (100 – 50000) mg/kg\nsrebro (0,10 – 100) mg/kg\nstront (0,30 – 500) mg/kg\ntal (5,00 – 100) mg/kg\ntytan (0,10 – 100) mg/kg\nwanad (0,50 – 500) mg/kg\nwapń (1,00 – 200000) mg/kg\nżelazo (0,40 – 15000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Materialy budowlane: piasek, kruszywo, zuzel Zakres:\nantymon (5,00 – 1000) mg/kg\narsen (5,00 – 1000) mg/kg\nbar (0,10 – 1000) mg/kg\nberyl (0,10 – 200) mg/kg\nbizmut (1,00 – 100) mg/kg\nbor (1,50 – 500) mg/kg\nchrom (0,30 – 1000) mg/kg\ncyna (5,00 – 1000) mg/kg\ncynk (0,50 – 10000) mg/kg\nfosfor (5,00 – 100000) mg/kg\nglin (1,00 – 1000) mg/kg\nkadm (0,050 – 200) mg/kg\nkrzem (5,00 – 1000) mg/kg\nkobalt (0,20 – 200) mg/kg\nmagnez (0,70 – 25000) mg/kg\nmangan (0,10 – 500) mg/kg\nmiedz (0,40 – 5000) mg/kg\nmolibden (0,40 – 100) mg/kg\nnikiel (0,40 – 1000) mg/kg\nolow (1,00 – 3000) mg/kg\npotas (100 – 10000) mg/kg\nsod (100 – 50000) mg/kg\nsrebro (0,10 – 100) mg/kg\nstront (0,30 – 500) mg/kg\ntal (5,00 – 100) mg/kg\ntytan (0,10 – 100) mg/kg\nwanad (0,50 – 500) mg/kg\nwapn (1,00 – 200000) mg/kg\nzelazo (0,40 – 15000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["materials","construction"],"row_index":235,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"antimony","range":"(5,00 – 1000) mg/kg"},{"name":"arsenic","range":"(5,00 – 1000) mg/kg"},{"name":"barium","range":"(0,10 – 1000) mg/kg"},{"name":"beryllium","range":"(0,10 – 200) mg/kg"},{"name":"bismuth","range":"(1,00 – 100) mg/kg"},{"name":"boron","range":"(1,50 – 500) mg/kg"},{"name":"chromium","range":"(0,30 – 1000) mg/kg"},{"name":"tin","range":"(5,00 – 1000) mg/kg"},{"name":"zinc","range":"(0,50 – 10000) mg/kg"},{"name":"phosphorus","range":"(5,00 – 100000) mg/kg"},{"name":"aluminium","range":"(1,00 – 1000) mg/kg"},{"name":"cadmium","range":"(0,050 – 200) mg/kg"},{"name":"silicon","range":"(5,00 – 1000) mg/kg"},{"name":"cobalt","range":"(0,20 – 200) mg/kg"},{"name":"magnesium","range":"(0,70 – 25000) mg/kg"},{"name":"manganese","range":"(0,10 – 500) mg/kg"},{"name":"copper","range":"(0,40 – 5000) mg/kg"},{"name":"molybdenum","range":"(0,40 – 100) mg/kg"},{"name":"nickel","range":"(0,40 – 1000) mg/kg"},{"name":"lead","range":"(1,00 – 3000) mg/kg"},{"name":"potassium","range":"(100 – 10000) mg/kg"},{"name":"sodium","range":"(100 – 50000) mg/kg"},{"name":"silver","range":"(0,10 – 100) mg/kg"},{"name":"strontium","range":"(0,30 – 500) mg/kg"},{"name":"thallium","range":"(5,00 – 100) mg/kg"},{"name":"titanium","range":"(0,10 – 100) mg/kg"},{"name":"vanadium","range":"(0,50 – 500) mg/kg"},{"name":"calcium","range":"(1,00 – 200000) mg/kg"},{"name":"iron","range":"(0,40 – 15000) mg/kg"}],"search_en":"Construction materials: sand, aggregate, slag Inductively coupled plasma optical emission spectrometry (ICP-OES) antimony arsenic barium beryllium bismuth boron chromium tin zinc phosphorus aluminium cadmium silicon cobalt magnesium manganese copper molybdenum nickel lead potassium sodium silver strontium thallium titanium vanadium calcium iron PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"锑","range":"(5,00 – 1000) mg/kg"},{"name":"砷","range":"(5,00 – 1000) mg/kg"},{"name":"钡","range":"(0,10 – 1000) mg/kg"},{"name":"铍","range":"(0,10 – 200) mg/kg"},{"name":"bizmut","range":"(1,00 – 100) mg/kg"},{"name":"硼","range":"(1,50 – 500) mg/kg"},{"name":"铬","range":"(0,30 – 1000) mg/kg"},{"name":"锡","range":"(5,00 – 1000) mg/kg"},{"name":"锌","range":"(0,50 – 10000) mg/kg"},{"name":"磷","range":"(5,00 – 100000) mg/kg"},{"name":"铝","range":"(1,00 – 1000) mg/kg"},{"name":"镉","range":"(0,050 – 200) mg/kg"},{"name":"硅","range":"(5,00 – 1000) mg/kg"},{"name":"钴","range":"(0,20 – 200) mg/kg"},{"name":"镁","range":"(0,70 – 25000) mg/kg"},{"name":"锰","range":"(0,10 – 500) mg/kg"},{"name":"铜","range":"(0,40 – 5000) mg/kg"},{"name":"钼","range":"(0,40 – 100) mg/kg"},{"name":"镍","range":"(0,40 – 1000) mg/kg"},{"name":"铅","range":"(1,00 – 3000) mg/kg"},{"name":"钾","range":"(100 – 10000) mg/kg"},{"name":"钠","range":"(100 – 50000) mg/kg"},{"name":"银","range":"(0,10 – 100) mg/kg"},{"name":"锶","range":"(0,30 – 500) mg/kg"},{"name":"铊","range":"(5,00 – 100) mg/kg"},{"name":"钛","range":"(0,10 – 100) mg/kg"},{"name":"钒","range":"(0,50 – 500) mg/kg"},{"name":"钙","range":"(1,00 – 200000) mg/kg"},{"name":"铁","range":"(0,40 – 15000) mg/kg"}],"search_zh":"建筑材料：砂、骨料、炉渣 电感耦合等离子体原子发射光谱法（ICP-OES） 锑 砷 钡 铍 硼 铬 锡 锌 磷 铝 镉 硅 钴 镁 锰 铜 钼 镍 铅 钾 钠 银 锶 铊 钛 钒 钙 铁 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c55b4","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Zawartość polichlorowanych bifenyli (PCB)","parameters":[{"name":"PCB 28","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 52","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 101","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 118","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 138","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 153","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 180","range":"(0,020 – 2,5) mg/kg"},{"name":"Suma polichlorowanych bifenyli (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,020 – 2,5) mg/kg\nPCB 52 (0,020 – 2,5) mg/kg\nPCB 101 (0,020 – 2,5) mg/kg\nPCB 118 (0,020 – 2,5) mg/kg\nPCB 138 (0,020 – 2,5) mg/kg\nPCB 153 (0,020 – 2,5) mg/kg\nPCB 180 (0,020 – 2,5) mg/kg\nSuma polichlorowanych bifenyli (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"EFO/PB/43/B:05.09.2025","norm_bases":["EFO/PB/43/B:05.09.2025"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Zawartość polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,020 – 2,5) mg/kg\nPCB 52 (0,020 – 2,5) mg/kg\nPCB 101 (0,020 – 2,5) mg/kg\nPCB 118 (0,020 – 2,5) mg/kg\nPCB 138 (0,020 – 2,5) mg/kg\nPCB 153 (0,020 – 2,5) mg/kg\nPCB 180 (0,020 – 2,5) mg/kg\nSuma polichlorowanych bifenyli (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) EFO/PB/43/B:05.09.2025 Materialy budowlane: piasek, kruszywo, zuzel Zawartosc polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,020 – 2,5) mg/kg\nPCB 52 (0,020 – 2,5) mg/kg\nPCB 101 (0,020 – 2,5) mg/kg\nPCB 118 (0,020 – 2,5) mg/kg\nPCB 138 (0,020 – 2,5) mg/kg\nPCB 153 (0,020 – 2,5) mg/kg\nPCB 180 (0,020 – 2,5) mg/kg\nSuma polichlorowanych bifenyli (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) EFO/PB/43/B:05.09.2025","categories":["materials","construction"],"row_index":236,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polychlorinated biphenyls (PCB) content","parameters_en":[{"name":"PCB 28","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 52","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 101","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 118","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 138","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 153","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 180","range":"(0,020 – 2,5) mg/kg"},{"name":"Sum of polychlorinated biphenyls (calculated)"}],"search_en":"Construction materials: sand, aggregate, slag Polychlorinated biphenyls (PCB) content Gas chromatography with mass spectrometry detection (GC-MS) PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 Sum of polychlorinated biphenyls (calculated) EFO/PB/43/B:05.09.2025","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Construction materials: sand, aggregate, slag","search_zh":"建筑材料：砂、骨料、炉渣 多氯联苯（PCB）含量 气相色谱-质谱法（GC-MS） PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 多氯联苯总量（由计算得出） EFO/PB/43/B:05.09.2025","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"建筑材料：砂、骨料、炉渣","parameters_zh":[{"name":"PCB 28","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 52","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 101","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 118","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 138","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 153","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 180","range":"(0,020 – 2,5) mg/kg"},{"name":"多氯联苯总量（由计算得出）"}],"methodology_zh":"多氯联苯（PCB）含量"},{"_id":"6a832b7f884ede9a1b2c55b5","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych","parameters":[{"name":"naftalen","range":"(0,005 – 100) mg/kg"},{"name":"antracen","range":"(0,005 – 100) mg/kg"},{"name":"chryzen","range":"(0,005 – 100) mg/kg"},{"name":"benzo(a)antracen","range":"(0,005 – 100) mg/kg"},{"name":"dibenzo(a,h)antracen"},{"name":"Zakres","range":"0,005 – 100) mg/kg"},{"name":"benzo(a)piren","range":"(0,005 – 100) mg/kg"},{"name":"benzo(b)fluoranten","range":"(0,005 – 100) mg/kg"},{"name":"benzo(k)fluoranten","range":"(0,005 – 100) mg/kg"},{"name":"benzo(ghi)perylen","range":"(0,005 – 100) mg/kg"},{"name":"indeno","range":"(1,2,3-cd)piren"},{"name":"(0,005 – 100) mg/kg"},{"name":"acenaften","range":"(0,005 – 100) mg/kg"},{"name":"acenaftylen","range":"(0,005 – 100) mg/kg"},{"name":"fluoranten","range":"(0,005 – 100) mg/kg"},{"name":"fluoren","range":"(0,005 – 100) mg/kg"},{"name":"fenantren","range":"(0,005 – 100) mg/kg"},{"name":"piren","range":"(0,005 – 100) mg/kg"},{"name":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń) badane cechy/metoda"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych\nZakres:\nnaftalen (0,005 – 100) mg/kg\nantracen (0,005 – 100) mg/kg\nchryzen (0,005 – 100) mg/kg\nbenzo(a)antracen (0,005 – 100) mg/kg\ndibenzo(a,h)antracen\nZakres 0,005 – 100) mg/kg\nbenzo(a)piren (0,005 – 100) mg/kg\nbenzo(b)fluoranten (0,005 – 100) mg/kg\nbenzo(k)fluoranten (0,005 – 100) mg/kg\nbenzo(ghi)perylen (0,005 – 100) mg/kg\nindeno (1,2,3-cd)piren\n(0,005 – 100) mg/kg\nacenaften (0,005 – 100) mg/kg\nacenaftylen (0,005 – 100) mg/kg\nfluoranten (0,005 – 100) mg/kg\nfluoren (0,005 – 100) mg/kg\nfenantren (0,005 – 100) mg/kg\npiren (0,005 – 100) mg/kg\nSuma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń) badane cechy/metoda\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"EFO/PB/44/B:05.09.2025 Dokumenty odniesienia","norm_bases":["EFO/PB/44/B:05.09.2025 Dokumenty odniesienia"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Zawartość wielopierścieniowych węglowodorów aromatycznych\nZakres:\nnaftalen (0,005 – 100) mg/kg\nantracen (0,005 – 100) mg/kg\nchryzen (0,005 – 100) mg/kg\nbenzo(a)antracen (0,005 – 100) mg/kg\ndibenzo(a,h)antracen\nZakres 0,005 – 100) mg/kg\nbenzo(a)piren (0,005 – 100) mg/kg\nbenzo(b)fluoranten (0,005 – 100) mg/kg\nbenzo(k)fluoranten (0,005 – 100) mg/kg\nbenzo(ghi)perylen (0,005 – 100) mg/kg\nindeno (1,2,3-cd)piren\n(0,005 – 100) mg/kg\nacenaften (0,005 – 100) mg/kg\nacenaftylen (0,005 – 100) mg/kg\nfluoranten (0,005 – 100) mg/kg\nfluoren (0,005 – 100) mg/kg\nfenantren (0,005 – 100) mg/kg\npiren (0,005 – 100) mg/kg\nSuma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń) badane cechy/metoda\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) EFO/PB/44/B:05.09.2025 Dokumenty odniesienia Materialy budowlane: piasek, kruszywo, zuzel Zawartosc wielopierscieniowych weglowodorow aromatycznych\nZakres:\nnaftalen (0,005 – 100) mg/kg\nantracen (0,005 – 100) mg/kg\nchryzen (0,005 – 100) mg/kg\nbenzo(a)antracen (0,005 – 100) mg/kg\ndibenzo(a,h)antracen\nZakres 0,005 – 100) mg/kg\nbenzo(a)piren (0,005 – 100) mg/kg\nbenzo(b)fluoranten (0,005 – 100) mg/kg\nbenzo(k)fluoranten (0,005 – 100) mg/kg\nbenzo(ghi)perylen (0,005 – 100) mg/kg\nindeno (1,2,3-cd)piren\n(0,005 – 100) mg/kg\nacenaften (0,005 – 100) mg/kg\nacenaftylen (0,005 – 100) mg/kg\nfluoranten (0,005 – 100) mg/kg\nfluoren (0,005 – 100) mg/kg\nfenantren (0,005 – 100) mg/kg\npiren (0,005 – 100) mg/kg\nSuma wielopierscieniowych weglowodorow aromatycznych (WWA) (z obliczen) badane cechy/metoda\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) EFO/PB/44/B:05.09.2025 Dokumenty odniesienia","categories":["materials","construction"],"row_index":237,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of polycyclic aromatic hydrocarbons","parameters_en":[{"name":"naphthalene","range":"(0,005 – 100) mg/kg"},{"name":"anthracene","range":"(0,005 – 100) mg/kg"},{"name":"chrysene","range":"(0,005 – 100) mg/kg"},{"name":"benzo(a)anthracene","range":"(0,005 – 100) mg/kg"},{"name":"dibenzo(a,h)anthracene"},{"name":"Range","range":"0,005 – 100) mg/kg"},{"name":"benzo(a)pyrene","range":"(0,005 – 100) mg/kg"},{"name":"benzo(b)fluoranthene","range":"(0,005 – 100) mg/kg"},{"name":"benzo(k)fluoranthene","range":"(0,005 – 100) mg/kg"},{"name":"benzo(ghi)perylene","range":"(0,005 – 100) mg/kg"},{"name":"indeno","range":"(1,2,3-cd)piren"},{"name":"(0,005 – 100) mg/kg"},{"name":"acenaphthene","range":"(0,005 – 100) mg/kg"},{"name":"acenaphthylene","range":"(0,005 – 100) mg/kg"},{"name":"fluoranthene","range":"(0,005 – 100) mg/kg"},{"name":"fluorene","range":"(0,005 – 100) mg/kg"},{"name":"phenanthrene","range":"(0,005 – 100) mg/kg"},{"name":"pyrene","range":"(0,005 – 100) mg/kg"},{"name":"Sum of polycyclic aromatic hydrocarbons (PAH) (calculated) tested characteristics/method"}],"search_en":"Construction materials: sand, aggregate, slag Content of polycyclic aromatic hydrocarbons Gas chromatography with mass spectrometry detection (GC-MS) naphthalene anthracene chrysene benzo(a)anthracene dibenzo(a,h)anthracene Range benzo(a)pyrene benzo(b)fluoranthene benzo(k)fluoranthene benzo(ghi)perylene indeno (0,005 – 100) mg/kg acenaphthene acenaphthylene fluoranthene fluorene phenanthrene pyrene Sum of polycyclic aromatic hydrocarbons (PAH) (calculated) tested characteristics/method EFO/PB/44/B:05.09.2025 Dokumenty odniesienia","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"萘","range":"(0,005 – 100) mg/kg"},{"name":"蒽","range":"(0,005 – 100) mg/kg"},{"name":"䓛","range":"(0,005 – 100) mg/kg"},{"name":"苯并（a）蒽","range":"(0,005 – 100) mg/kg"},{"name":"二苯并（a,h）蒽"},{"name":"范围","range":"0,005 – 100) mg/kg"},{"name":"苯并（a）芘","range":"(0,005 – 100) mg/kg"},{"name":"苯并（b）荧蒽","range":"(0,005 – 100) mg/kg"},{"name":"苯并（k）荧蒽","range":"(0,005 – 100) mg/kg"},{"name":"苯并（ghi）苝","range":"(0,005 – 100) mg/kg"},{"name":"茚","range":"(1,2,3-cd)piren"},{"name":"(0,005 – 100) mg/kg"},{"name":"苊","range":"(0,005 – 100) mg/kg"},{"name":"苊烯","range":"(0,005 – 100) mg/kg"},{"name":"荧蒽","range":"(0,005 – 100) mg/kg"},{"name":"芴","range":"(0,005 – 100) mg/kg"},{"name":"菲","range":"(0,005 – 100) mg/kg"},{"name":"芘","range":"(0,005 – 100) mg/kg"},{"name":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń) badane cechy/metoda"}],"search_zh":"建筑材料：砂、骨料、炉渣 多环芳烃含量 气相色谱-质谱法（GC-MS） 萘 蒽 䓛 苯并（a）蒽 二苯并（a,h）蒽 范围 苯并（a）芘 苯并（b）荧蒽 苯并（k）荧蒽 苯并（ghi）苝 茚 苊 苊烯 荧蒽 芴 菲 芘 EFO/PB/44/B:05.09.2025 Dokumenty odniesienia","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"建筑材料：砂、骨料、炉渣","methodology_zh":"多环芳烃含量"},{"_id":"6a832b7f884ede9a1b2c55b6","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Zawartość rtęci","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość rtęci","reference":"PN-EN 13657:2006","norm_bases":["PN-EN 13657:2006"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Zawartość rtęci PN-EN 13657:2006 Materialy budowlane: piasek, kruszywo, zuzel Zawartosc rteci PN-EN 13657:2006","categories":["materials","construction"],"row_index":238,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","search_en":"Construction materials: sand, aggregate, slag Mercury content PN-EN 13657:2006","test_object_en":"Construction materials: sand, aggregate, slag","methodology_zh":"汞含量","search_zh":"建筑材料：砂、骨料、炉渣 汞含量 PN-EN 13657:2006","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c55b7","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"","parameters":[{"name":"Zakres","range":"(0,05 – 25,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zakres (0,05 – 25,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012 +Ap1:2016-07","norm_bases":["PN-EN ISO 12846:2012 +Ap1:2016-07"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Zakres (0,05 – 25,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 +Ap1:2016-07 Materialy budowlane: piasek, kruszywo, zuzel Zakres (0,05 – 25,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 +Ap1:2016-07","categories":["materials","construction"],"row_index":239,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,05 – 25,0) mg/kg"}],"search_en":"Construction materials: sand, aggregate, slag Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN ISO 12846:2012 +Ap1:2016-07","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(0,05 – 25,0) mg/kg"}],"search_zh":"建筑材料：砂、骨料、炉渣 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN ISO 12846:2012 +Ap1:2016-07","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"建筑材料：砂、骨料、炉渣"},{"_id":"6a832b7f884ede9a1b2c55b8","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Zawartość siarczanów","parameters":[{"name":"Zakres","range":"(100 – 50000) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość siarczanów\nZakres (100 – 50000) mg/kg\nMetoda wagowa","reference":"PN-ISO 11048:2002","norm_bases":["PN-ISO 11048:2002"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Zawartość siarczanów\nZakres (100 – 50000) mg/kg\nMetoda wagowa PN-ISO 11048:2002 Materialy budowlane: piasek, kruszywo, zuzel Zawartosc siarczanow\nZakres (100 – 50000) mg/kg\nMetoda wagowa PN-ISO 11048:2002","categories":["materials","construction"],"row_index":240,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate content","parameters_en":[{"name":"Range","range":"(100 – 50000) mg/kg"}],"search_en":"Construction materials: sand, aggregate, slag Sulfate content Gravimetric method Range PN-ISO 11048:2002","technique_en":"Gravimetric method","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(100 – 50000) mg/kg"}],"search_zh":"建筑材料：砂、骨料、炉渣 硫酸盐含量 重量法 范围 PN-ISO 11048:2002","technique_zh":"重量法","test_object_zh":"建筑材料：砂、骨料、炉渣","methodology_zh":"硫酸盐含量"},{"_id":"6a832b7f884ede9a1b2c55b9","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Zawartość siarczków","parameters":[{"name":"Zakres","range":"(2,0 – 100) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość siarczków\nZakres (2,0 – 100) mg/kg\nMetoda miareczkowa","reference":"PB/FCH/22/C:10.04.2017","norm_bases":["PB/FCH/22/C:10.04.2017"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Zawartość siarczków\nZakres (2,0 – 100) mg/kg\nMetoda miareczkowa PB/FCH/22/C:10.04.2017 Materialy budowlane: piasek, kruszywo, zuzel Zawartosc siarczkow\nZakres (2,0 – 100) mg/kg\nMetoda miareczkowa PB/FCH/22/C:10.04.2017","categories":["materials","construction"],"row_index":241,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfide content","parameters_en":[{"name":"Range","range":"(2,0 – 100) mg/kg"}],"search_en":"Construction materials: sand, aggregate, slag Sulfide content Titrimetric method Range PB/FCH/22/C:10.04.2017","technique_en":"Titrimetric method","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(2,0 – 100) mg/kg"}],"search_zh":"建筑材料：砂、骨料、炉渣 硫化物含量 滴定法 范围 PB/FCH/22/C:10.04.2017","technique_zh":"滴定法","test_object_zh":"建筑材料：砂、骨料、炉渣","methodology_zh":"硫化物含量"},{"_id":"6a832b7f884ede9a1b2c55ba","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Materiały budowlane: piasek, kruszywo, żużel","methodology":"Sucha masa / zawartość wody","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa / zawartość wody\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 metoda A","norm_bases":["PN-EN 15934:2013-02 metoda A"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały budowlane: piasek, kruszywo, żużel Sucha masa / zawartość wody\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A Materialy budowlane: piasek, kruszywo, zuzel Sucha masa / zawartosc wody\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A","categories":["materials","construction","water"],"row_index":242,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter / water content","parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"search_en":"Construction materials: sand, aggregate, slag Dry matter / water content Gravimetric method Range PN-EN 15934:2013-02 metoda A","technique_en":"Gravimetric method","test_object_en":"Construction materials: sand, aggregate, slag","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"建筑材料：砂、骨料、炉渣 干物质 / 水分含量 重量法 范围 PN-EN 15934:2013-02 metoda A","technique_zh":"重量法","test_object_zh":"建筑材料：砂、骨料、炉渣","methodology_zh":"干物质 / 水分含量"},{"_id":"6a832b7f884ede9a1b2c55bb","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 12 12, 20 03 01, 20 03 99; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Aktywność oddechowa AT4","parameters":[{"name":"Zakres","range":"(1,0 – 60,0) mg/g"}],"technique":"Metoda manometryczna","techniques":["Metoda manometryczna"],"computed":[],"activity":"Aktywność oddechowa AT4\nZakres (1,0 – 60,0) mg/g\nMetoda manometryczna","reference":"PB/FCH/82/C:04.06.2018","norm_bases":["PB/FCH/82/C:04.06.2018"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 12 12, 20 03 01, 20 03 99; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Aktywność oddechowa AT4\nZakres (1,0 – 60,0) mg/g\nMetoda manometryczna PB/FCH/82/C:04.06.2018 Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 12 12, 20 03 01, 20 03 99; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Aktywnosc oddechowa AT4\nZakres (1,0 – 60,0) mg/g\nMetoda manometryczna PB/FCH/82/C:04.06.2018","categories":["environment","metrology"],"row_index":243,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Respiration activity AT4","parameters_en":[{"name":"Range","range":"(1,0 – 60,0) mg/g"}],"search_en":"Respiration activity AT4 Manometric method Range PB/FCH/82/C:04.06.2018","technique_en":"Manometric method","parameters_zh":[{"name":"范围","range":"(1,0 – 60,0) mg/g"}],"search_zh":"呼吸活性 AT4 压力计法 范围 PB/FCH/82/C:04.06.2018","technique_zh":"压力计法","methodology_zh":"呼吸活性 AT4"},{"_id":"6a832b7f884ede9a1b2c55bc","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 13,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 13,0\nMetoda potencjometryczna","reference":"ISO 10390:2005 | PN-EN ISO 10390:2022-09 | DIN 38404-5 (07.09)","norm_bases":["ISO 10390:2005","PN-EN ISO 10390:2022-09","DIN 38404-5 (07.09)"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów pH\nZakres 2,0 – 13,0\nMetoda potencjometryczna ISO 10390:2005 | PN-EN ISO 10390:2022-09 | DIN 38404-5 (07.09) Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow pH\nZakres 2,0 – 13,0\nMetoda potencjometryczna ISO 10390:2005 | PN-EN ISO 10390:2022-09 | DIN 38404-5 (07.09)","categories":["environment"],"row_index":244,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 13,0"}],"search_en":"pH Potentiometric method Range ISO 10390:2005 | PN-EN ISO 10390:2022-09 | DIN 38404-5 (07.09)","technique_en":"Potentiometric method","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 13,0"}],"search_zh":"pH 值 电位法 范围 ISO 10390:2005 | PN-EN ISO 10390:2022-09 | DIN 38404-5 (07.09)","technique_zh":"电位法"},{"_id":"6a832b7f884ede9a1b2c55bd","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady kod: 05 06 03*, 07 02 99, 10 12 01, 19 05 99, 19 08 01, 19 08 05, 19 12 10, 19 12 12, 20 03 01, 20 03 07; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość frakcji biodegradowalnej (zawartość biomasy)","parameters":[{"name":"Zakres","range":"(5,0 – 90,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość frakcji biodegradowalnej (zawartość biomasy)\nZakres (5,0 – 90,0) %\nMetoda wagowa","reference":"PN-EN ISO 21644:2021-07 annex B","norm_bases":["PN-EN ISO 21644:2021-07 annex B"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady kod: 05 06 03*, 07 02 99, 10 12 01, 19 05 99, 19 08 01, 19 08 05, 19 12 10, 19 12 12, 20 03 01, 20 03 07; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość frakcji biodegradowalnej (zawartość biomasy)\nZakres (5,0 – 90,0) %\nMetoda wagowa PN-EN ISO 21644:2021-07 annex B Odpady kod: 05 06 03*, 07 02 99, 10 12 01, 19 05 99, 19 08 01, 19 08 05, 19 12 10, 19 12 12, 20 03 01, 20 03 07; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc frakcji biodegradowalnej (zawartosc biomasy)\nZakres (5,0 – 90,0) %\nMetoda wagowa PN-EN ISO 21644:2021-07 annex B","categories":["environment"],"row_index":245,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biodegradable fraction content (biomass content)","parameters_en":[{"name":"Range","range":"(5,0 – 90,0) %"}],"search_en":"Biodegradable fraction content (biomass content) Gravimetric method Range PN-EN ISO 21644:2021-07 annex B","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(5,0 – 90,0) %"}],"search_zh":"重量法 范围 PN-EN ISO 21644:2021-07 annex B","technique_zh":"重量法"},{"_id":"6a832b7f884ede9a1b2c55be","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07,17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość ekstrahowalnych związków chloroorganicznych (EOX)","parameters":[{"name":"Zakres","range":"(1,0 -100) mg/kg"}],"technique":"Metoda kulometryczna","techniques":["Metoda kulometryczna"],"computed":[],"activity":"Zawartość ekstrahowalnych związków chloroorganicznych (EOX)\nZakres (1,0 -100) mg/kg\nMetoda kulometryczna","reference":"DIN 38414-17:2017-01","norm_bases":["DIN 38414-17:2017-01"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07,17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość ekstrahowalnych związków chloroorganicznych (EOX)\nZakres (1,0 -100) mg/kg\nMetoda kulometryczna DIN 38414-17:2017-01 Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07,17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc ekstrahowalnych zwiazkow chloroorganicznych (EOX)\nZakres (1,0 -100) mg/kg\nMetoda kulometryczna DIN 38414-17:2017-01","categories":["environment"],"row_index":246,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Extractable organochlorine compound content (EOX)","parameters_en":[{"name":"Range","range":"(1,0 -100) mg/kg"}],"search_en":"Extractable organochlorine compound content (EOX) Coulometric method Range DIN 38414-17:2017-01","technique_en":"Coulometric method","parameters_zh":[{"name":"范围","range":"(1,0 -100) mg/kg"}],"search_zh":"范围 DIN 38414-17:2017-01"},{"_id":"6a832b7f884ede9a1b2c55bf","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07,17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Obecność węglanów","parameters":[],"technique":"Metoda jakościowa","techniques":["Metoda jakościowa"],"computed":[],"activity":"Obecność węglanów\nMetoda jakościowa","reference":"EFO/PB/02/A: 10.04.2022","norm_bases":["EFO/PB/02/A: 10.04.2022"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07,17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Obecność węglanów\nMetoda jakościowa EFO/PB/02/A: 10.04.2022 Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07,17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Obecnosc weglanow\nMetoda jakosciowa EFO/PB/02/A: 10.04.2022","categories":["environment"],"row_index":247,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of carbonates","search_en":"Presence of carbonates Qualitative method EFO/PB/02/A: 10.04.2022","technique_en":"Qualitative method","search_zh":"定性法 EFO/PB/02/A: 10.04.2022","technique_zh":"定性法"},{"_id":"6a832b7f884ede9a1b2c55c0","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Wyciągi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07,17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,00020 – 5,00) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,00020 – 5,00) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 12457-4:2006 | DIN 1483:2007 | PN-EN ISO 12846:2012 +Ap1:2016-07","norm_bases":["PN-EN 12457-4:2006","DIN 1483:2007","PN-EN ISO 12846:2012 +Ap1:2016-07"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyciągi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07,17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Stężenie rtęci\nZakres (0,00020 – 5,00) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 12457-4:2006 | DIN 1483:2007 | PN-EN ISO 12846:2012 +Ap1:2016-07 Wyciagi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07,17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Stezenie rteci\nZakres (0,00020 – 5,00) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 12457-4:2006 | DIN 1483:2007 | PN-EN ISO 12846:2012 +Ap1:2016-07","categories":["environment"],"row_index":248,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,00020 – 5,00) mg/l"}],"search_en":"Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 12457-4:2006 | DIN 1483:2007 | PN-EN ISO 12846:2012 +Ap1:2016-07","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,00020 – 5,00) mg/l"}],"search_zh":"汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 12457-4:2006 | DIN 1483:2007 | PN-EN ISO 12846:2012 +Ap1:2016-07","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a832b7f884ede9a1b2c55c1","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07,17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,0020 – 50,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,0020 – 50,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 12457-4:2006 | DIN 1483:2007 | PN-EN ISO 12846:2012 +Ap1:2016-07","norm_bases":["PN-EN 12457-4:2006","DIN 1483:2007","PN-EN ISO 12846:2012 +Ap1:2016-07"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07,17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość rtęci\nZakres (0,0020 – 50,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 12457-4:2006 | DIN 1483:2007 | PN-EN ISO 12846:2012 +Ap1:2016-07 Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07,17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc rteci\nZakres (0,0020 – 50,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 12457-4:2006 | DIN 1483:2007 | PN-EN ISO 12846:2012 +Ap1:2016-07","categories":["environment"],"row_index":249,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,0020 – 50,0) mg/kg"}],"search_en":"Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 12457-4:2006 | DIN 1483:2007 | PN-EN ISO 12846:2012 +Ap1:2016-07","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,0020 – 50,0) mg/kg"}],"search_zh":"汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 12457-4:2006 | DIN 1483:2007 | PN-EN ISO 12846:2012 +Ap1:2016-07","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a832b7f884ede9a1b2c55c2","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Wyciągi wodne: Gleba, grunty, Materiały budowlane, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Temperatura wyciągu wodnego","parameters":[{"name":"Zakres","range":"(15,0 – 25,0) °C"}],"technique":"Metoda pomiaru bezpośredniego","techniques":["Metoda pomiaru bezpośredniego"],"computed":[],"activity":"Temperatura wyciągu wodnego\nZakres (15,0 – 25,0) °C\nMetoda pomiaru bezpośredniego","reference":"EFO/PB/06/A: 10.04.2022 | DIN 38404-4:1976-12","norm_bases":["EFO/PB/06/A: 10.04.2022","DIN 38404-4:1976-12"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyciągi wodne: Gleba, grunty, Materiały budowlane, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Temperatura wyciągu wodnego\nZakres (15,0 – 25,0) °C\nMetoda pomiaru bezpośredniego EFO/PB/06/A: 10.04.2022 | DIN 38404-4:1976-12 Wyciagi wodne: Gleba, grunty, Materialy budowlane, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Temperatura wyciagu wodnego\nZakres (15,0 – 25,0) °C\nMetoda pomiaru bezposredniego EFO/PB/06/A: 10.04.2022 | DIN 38404-4:1976-12","categories":["environment","materials","construction"],"row_index":250,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of the water extract","parameters_en":[{"name":"Range","range":"(15,0 – 25,0) °C"}],"search_en":"Temperature of the water extract Direct measurement method Range EFO/PB/06/A: 10.04.2022 | DIN 38404-4:1976-12","technique_en":"Direct measurement method","parameters_zh":[{"name":"范围","range":"(15,0 – 25,0) °C"}],"search_zh":"直接测量法 范围 EFO/PB/06/A: 10.04.2022 | DIN 38404-4:1976-12","technique_zh":"直接测量法"},{"_id":"6a832b7f884ede9a1b2c55c3","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość pierwiastków","parameters":[{"name":"antymon","range":"(2,0 – 500) mg/kg"},{"name":"arsen","range":"(0,50 – 100) mg/kg"},{"name":"bar","range":"(1,0 – 5000) mg/kg"},{"name":"beryl","range":"(2,0 – 100) mg/kg"},{"name":"bor","range":"(50 – 1000) mg/kg"},{"name":"chrom","range":"(1,0 – 500) mg/kg"},{"name":"cyna","range":"(1,0 – 100) mg/kg"},{"name":"cynk","range":"(5,0 – 5000) mg/kg"},{"name":"fosfor","range":"(20 – 1000) mg/kg"},{"name":"glin","range":"(20 – 1000) mg/kg"},{"name":"kadm","range":"(0,20 – 100) mg/kg"},{"name":"kobalt","range":"(1,0 – 1000) mg/kg"},{"name":"krzem","range":"(1000 – 5000) mg/kg"},{"name":"lit","range":"(10 – 500) mg/kg"},{"name":"magnez","range":"(100 – 500000) mg/kg"},{"name":"mangan","range":"(10 – 1000) mg/kg"},{"name":"miedź","range":"(1,0 – 5000) mg/kg"},{"name":"molibden","range":"(1,0 – 1000) mg/kg"},{"name":"nikiel","range":"(1,0 – 5000) mg/kg"},{"name":"ołów","range":"(1,0 – 5000) mg/kg"},{"name":"potas","range":"(100 – 50000) mg/kg"},{"name":"rtęć","range":"(0,10 – 100) mg/kg"},{"name":"selen","range":"(2,0 – 500) mg/kg"},{"name":"srebro","range":"(2,0 – 500) mg/kg"},{"name":"stront","range":"(10 – 1000) mg/kg"},{"name":"sód","range":"(200 – 50000) mg/kg"},{"name":"tal","range":"(0,2 0 – 500) mg/kg"},{"name":"tytan","range":"(2,0 – 500) mg/kg"},{"name":"uran","range":"(2,0 – 500) mg/kg"},{"name":"wanad","range":"(2,0 – 500) mg/kg"},{"name":"wapń","range":"(200 – 500000) mg/kg"},{"name":"żelazo","range":"(20 – 50000) mg/kg"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nantymon (2,0 – 500) mg/kg\narsen (0,50 – 100) mg/kg\nbar (1,0 – 5000) mg/kg\nberyl (2,0 – 100) mg/kg\nbor (50 – 1000) mg/kg\nchrom (1,0 – 500) mg/kg\ncyna (1,0 – 100) mg/kg\ncynk (5,0 – 5000) mg/kg\nfosfor (20 – 1000) mg/kg\nglin (20 – 1000) mg/kg\nkadm (0,20 – 100) mg/kg\nkobalt (1,0 – 1000) mg/kg\nkrzem (1000 – 5000) mg/kg\nlit (10 – 500) mg/kg\nmagnez (100 – 500000) mg/kg\nmangan (10 – 1000) mg/kg\nmiedź (1,0 – 5000) mg/kg\nmolibden (1,0 – 1000) mg/kg\nnikiel (1,0 – 5000) mg/kg\nołów (1,0 – 5000) mg/kg\npotas (100 – 50000) mg/kg\nrtęć (0,10 – 100) mg/kg\nselen (2,0 – 500) mg/kg\nsrebro (2,0 – 500) mg/kg\nstront (10 – 1000) mg/kg\nsód (200 – 50000) mg/kg\ntal (0,2 0 – 500) mg/kg\ntytan (2,0 – 500) mg/kg\nuran (2,0 – 500) mg/kg\nwanad (2,0 – 500) mg/kg\nwapń (200 – 500000) mg/kg\nżelazo (20 – 50000) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN 16171:2017-02 | PN-EN ISO 17294-2:2024-04 | PN-EN 13657:2006","norm_bases":["PN-EN 16171:2017-02","PN-EN ISO 17294-2:2024-04","PN-EN 13657:2006"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość pierwiastków\nZakres:\nantymon (2,0 – 500) mg/kg\narsen (0,50 – 100) mg/kg\nbar (1,0 – 5000) mg/kg\nberyl (2,0 – 100) mg/kg\nbor (50 – 1000) mg/kg\nchrom (1,0 – 500) mg/kg\ncyna (1,0 – 100) mg/kg\ncynk (5,0 – 5000) mg/kg\nfosfor (20 – 1000) mg/kg\nglin (20 – 1000) mg/kg\nkadm (0,20 – 100) mg/kg\nkobalt (1,0 – 1000) mg/kg\nkrzem (1000 – 5000) mg/kg\nlit (10 – 500) mg/kg\nmagnez (100 – 500000) mg/kg\nmangan (10 – 1000) mg/kg\nmiedź (1,0 – 5000) mg/kg\nmolibden (1,0 – 1000) mg/kg\nnikiel (1,0 – 5000) mg/kg\nołów (1,0 – 5000) mg/kg\npotas (100 – 50000) mg/kg\nrtęć (0,10 – 100) mg/kg\nselen (2,0 – 500) mg/kg\nsrebro (2,0 – 500) mg/kg\nstront (10 – 1000) mg/kg\nsód (200 – 50000) mg/kg\ntal (0,2 0 – 500) mg/kg\ntytan (2,0 – 500) mg/kg\nuran (2,0 – 500) mg/kg\nwanad (2,0 – 500) mg/kg\nwapń (200 – 500000) mg/kg\nżelazo (20 – 50000) mg/kg\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN 16171:2017-02 | PN-EN ISO 17294-2:2024-04 | PN-EN 13657:2006 Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc pierwiastkow\nZakres:\nantymon (2,0 – 500) mg/kg\narsen (0,50 – 100) mg/kg\nbar (1,0 – 5000) mg/kg\nberyl (2,0 – 100) mg/kg\nbor (50 – 1000) mg/kg\nchrom (1,0 – 500) mg/kg\ncyna (1,0 – 100) mg/kg\ncynk (5,0 – 5000) mg/kg\nfosfor (20 – 1000) mg/kg\nglin (20 – 1000) mg/kg\nkadm (0,20 – 100) mg/kg\nkobalt (1,0 – 1000) mg/kg\nkrzem (1000 – 5000) mg/kg\nlit (10 – 500) mg/kg\nmagnez (100 – 500000) mg/kg\nmangan (10 – 1000) mg/kg\nmiedz (1,0 – 5000) mg/kg\nmolibden (1,0 – 1000) mg/kg\nnikiel (1,0 – 5000) mg/kg\nolow (1,0 – 5000) mg/kg\npotas (100 – 50000) mg/kg\nrtec (0,10 – 100) mg/kg\nselen (2,0 – 500) mg/kg\nsrebro (2,0 – 500) mg/kg\nstront (10 – 1000) mg/kg\nsod (200 – 50000) mg/kg\ntal (0,2 0 – 500) mg/kg\ntytan (2,0 – 500) mg/kg\nuran (2,0 – 500) mg/kg\nwanad (2,0 – 500) mg/kg\nwapn (200 – 500000) mg/kg\nzelazo (20 – 50000) mg/kg\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN 16171:2017-02 | PN-EN ISO 17294-2:2024-04 | PN-EN 13657:2006","categories":["environment","materials"],"row_index":251,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","parameters_en":[{"name":"antimony","range":"(2,0 – 500) mg/kg"},{"name":"arsenic","range":"(0,50 – 100) mg/kg"},{"name":"barium","range":"(1,0 – 5000) mg/kg"},{"name":"beryllium","range":"(2,0 – 100) mg/kg"},{"name":"boron","range":"(50 – 1000) mg/kg"},{"name":"chromium","range":"(1,0 – 500) mg/kg"},{"name":"tin","range":"(1,0 – 100) mg/kg"},{"name":"zinc","range":"(5,0 – 5000) mg/kg"},{"name":"phosphorus","range":"(20 – 1000) mg/kg"},{"name":"aluminium","range":"(20 – 1000) mg/kg"},{"name":"cadmium","range":"(0,20 – 100) mg/kg"},{"name":"cobalt","range":"(1,0 – 1000) mg/kg"},{"name":"silicon","range":"(1000 – 5000) mg/kg"},{"name":"lithium","range":"(10 – 500) mg/kg"},{"name":"magnesium","range":"(100 – 500000) mg/kg"},{"name":"manganese","range":"(10 – 1000) mg/kg"},{"name":"copper","range":"(1,0 – 5000) mg/kg"},{"name":"molybdenum","range":"(1,0 – 1000) mg/kg"},{"name":"nickel","range":"(1,0 – 5000) mg/kg"},{"name":"lead","range":"(1,0 – 5000) mg/kg"},{"name":"potassium","range":"(100 – 50000) mg/kg"},{"name":"mercury","range":"(0,10 – 100) mg/kg"},{"name":"selenium","range":"(2,0 – 500) mg/kg"},{"name":"silver","range":"(2,0 – 500) mg/kg"},{"name":"strontium","range":"(10 – 1000) mg/kg"},{"name":"sodium","range":"(200 – 50000) mg/kg"},{"name":"thallium","range":"(0,2 0 – 500) mg/kg"},{"name":"titanium","range":"(2,0 – 500) mg/kg"},{"name":"uranium","range":"(2,0 – 500) mg/kg"},{"name":"vanadium","range":"(2,0 – 500) mg/kg"},{"name":"calcium","range":"(200 – 500000) mg/kg"},{"name":"iron","range":"(20 – 50000) mg/kg"}],"search_en":"Element content Inductively coupled plasma mass spectrometry (ICP-MS) antimony arsenic barium beryllium boron chromium tin zinc phosphorus aluminium cadmium cobalt silicon lithium magnesium manganese copper molybdenum nickel lead potassium mercury selenium silver strontium sodium thallium titanium uranium vanadium calcium iron PN-EN 16171:2017-02 | PN-EN ISO 17294-2:2024-04 | PN-EN 13657:2006","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","methodology_zh":"元素含量","parameters_zh":[{"name":"锑","range":"(2,0 – 500) mg/kg"},{"name":"砷","range":"(0,50 – 100) mg/kg"},{"name":"钡","range":"(1,0 – 5000) mg/kg"},{"name":"铍","range":"(2,0 – 100) mg/kg"},{"name":"硼","range":"(50 – 1000) mg/kg"},{"name":"铬","range":"(1,0 – 500) mg/kg"},{"name":"锡","range":"(1,0 – 100) mg/kg"},{"name":"锌","range":"(5,0 – 5000) mg/kg"},{"name":"磷","range":"(20 – 1000) mg/kg"},{"name":"铝","range":"(20 – 1000) mg/kg"},{"name":"镉","range":"(0,20 – 100) mg/kg"},{"name":"钴","range":"(1,0 – 1000) mg/kg"},{"name":"硅","range":"(1000 – 5000) mg/kg"},{"name":"锂","range":"(10 – 500) mg/kg"},{"name":"镁","range":"(100 – 500000) mg/kg"},{"name":"锰","range":"(10 – 1000) mg/kg"},{"name":"铜","range":"(1,0 – 5000) mg/kg"},{"name":"钼","range":"(1,0 – 1000) mg/kg"},{"name":"镍","range":"(1,0 – 5000) mg/kg"},{"name":"铅","range":"(1,0 – 5000) mg/kg"},{"name":"钾","range":"(100 – 50000) mg/kg"},{"name":"汞","range":"(0,10 – 100) mg/kg"},{"name":"硒","range":"(2,0 – 500) mg/kg"},{"name":"银","range":"(2,0 – 500) mg/kg"},{"name":"锶","range":"(10 – 1000) mg/kg"},{"name":"钠","range":"(200 – 50000) mg/kg"},{"name":"铊","range":"(0,2 0 – 500) mg/kg"},{"name":"钛","range":"(2,0 – 500) mg/kg"},{"name":"铀","range":"(2,0 – 500) mg/kg"},{"name":"钒","range":"(2,0 – 500) mg/kg"},{"name":"钙","range":"(200 – 500000) mg/kg"},{"name":"铁","range":"(20 – 50000) mg/kg"}],"search_zh":"元素含量 电感耦合等离子体质谱法（ICP-MS） 锑 砷 钡 铍 硼 铬 锡 锌 磷 铝 镉 钴 硅 锂 镁 锰 铜 钼 镍 铅 钾 汞 硒 银 锶 钠 铊 钛 铀 钒 钙 铁 PN-EN 16171:2017-02 | PN-EN ISO 17294-2:2024-04 | PN-EN 13657:2006","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a832b7f884ede9a1b2c55c4","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość substancji lipofilowych (ekstrahowalne heksanem)","parameters":[{"name":"Zakres","range":"(0,020 – 20) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość substancji lipofilowych (ekstrahowalne heksanem)\nZakres (0,020 – 20) %\nMetoda wagowa","reference":"LAGA KW/04/ (12.09) EFO/PB/01/A: 01.04.2022","norm_bases":["LAGA KW/04/ (12.09) EFO/PB/01/A: 01.04.2022"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość substancji lipofilowych (ekstrahowalne heksanem)\nZakres (0,020 – 20) %\nMetoda wagowa LAGA KW/04/ (12.09) EFO/PB/01/A: 01.04.2022 Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc substancji lipofilowych (ekstrahowalne heksanem)\nZakres (0,020 – 20) %\nMetoda wagowa LAGA KW/04/ (12.09) EFO/PB/01/A: 01.04.2022","categories":["environment"],"row_index":252,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of lipophilic substances (hexane-extractable)","parameters_en":[{"name":"Range","range":"(0,020 – 20) %"}],"search_en":"Content of lipophilic substances (hexane-extractable) Gravimetric method Range LAGA KW/04/ (12.09) EFO/PB/01/A: 01.04.2022","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,020 – 20) %"}],"search_zh":"重量法 范围 LAGA KW/04/ (12.09) EFO/PB/01/A: 01.04.2022","technique_zh":"重量法"},{"_id":"6a832b7f884ede9a1b2c55c5","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady kod: 19 12 12 20 03 01; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(1,0 – 40,0) %"}],"technique":"Metoda termograwimetryczna","techniques":["Metoda termograwimetryczna"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 40,0) %\nMetoda termograwimetryczna","reference":"PN-EN ISO 21660-3:2021-08 EFO/PB/03/A:10.04.2022","norm_bases":["PN-EN ISO 21660-3:2021-08 EFO/PB/03/A:10.04.2022"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady kod: 19 12 12 20 03 01; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 40,0) %\nMetoda termograwimetryczna PN-EN ISO 21660-3:2021-08 EFO/PB/03/A:10.04.2022 Odpady kod: 19 12 12 20 03 01; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc wilgoci w probce analitycznej\nZakres (1,0 – 40,0) %\nMetoda termograwimetryczna PN-EN ISO 21660-3:2021-08 EFO/PB/03/A:10.04.2022","categories":["environment"],"row_index":253,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(1,0 – 40,0) %"}],"search_en":"Moisture content in the analytical sample Thermogravimetric method Range PN-EN ISO 21660-3:2021-08 EFO/PB/03/A:10.04.2022","technique_en":"Thermogravimetric method","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 40,0) %"}],"search_zh":"分析样品水分含量 热重法 范围 PN-EN ISO 21660-3:2021-08 EFO/PB/03/A:10.04.2022","technique_zh":"热重法"},{"_id":"6a832b7f884ede9a1b2c55c6","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady kod: 19 12 12 20 03 01; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość popiołu / pozostałość po spaleniu","parameters":[{"name":"Zakres","range":"(1,0 – 40,0) %"}],"technique":"Metoda termograwimetryczna","techniques":["Metoda termograwimetryczna"],"computed":[],"activity":"Zawartość popiołu / pozostałość po spaleniu\nZakres (1,0 – 40,0) %\nMetoda termograwimetryczna","reference":"PN-EN ISO 21656:2021-08 EFO/PB/03/A:10.04.2022","norm_bases":["PN-EN ISO 21656:2021-08 EFO/PB/03/A:10.04.2022"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady kod: 19 12 12 20 03 01; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość popiołu / pozostałość po spaleniu\nZakres (1,0 – 40,0) %\nMetoda termograwimetryczna PN-EN ISO 21656:2021-08 EFO/PB/03/A:10.04.2022 Odpady kod: 19 12 12 20 03 01; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc popiolu / pozostalosc po spaleniu\nZakres (1,0 – 40,0) %\nMetoda termograwimetryczna PN-EN ISO 21656:2021-08 EFO/PB/03/A:10.04.2022","categories":["environment"],"row_index":254,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content / residue on ignition","parameters_en":[{"name":"Range","range":"(1,0 – 40,0) %"}],"search_en":"Ash content / residue on ignition Thermogravimetric method Range PN-EN ISO 21656:2021-08 EFO/PB/03/A:10.04.2022","technique_en":"Thermogravimetric method","parameters_zh":[{"name":"范围","range":"(1,0 – 40,0) %"}],"search_zh":"灰分含量/燃烧残渣 热重法 范围 PN-EN ISO 21656:2021-08 EFO/PB/03/A:10.04.2022","technique_zh":"热重法","methodology_zh":"灰分含量/燃烧残渣"},{"_id":"6a832b7f884ede9a1b2c55c7","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady kod: 17 05 04, 19 01 12 19 12 10, 19 12 12; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość fluoru","parameters":[{"name":"Zakres","range":"(0,1 – 10,0) %"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Zawartość fluoru\nZakres (0,1 – 10,0) %\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN 15408:2011 | PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN 15408:2011","PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady kod: 17 05 04, 19 01 12 19 12 10, 19 12 12; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość fluoru\nZakres (0,1 – 10,0) %\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN 15408:2011 | PN-EN ISO 10304-1:2009+AC:2012 Odpady kod: 17 05 04, 19 01 12 19 12 10, 19 12 12; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc fluoru\nZakres (0,1 – 10,0) %\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN 15408:2011 | PN-EN ISO 10304-1:2009+AC:2012","categories":["environment"],"row_index":255,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluorine content","parameters_en":[{"name":"Range","range":"(0,1 – 10,0) %"}],"search_en":"Fluorine content Ion chromatography with conductometric detection (IC-CD) Range PN-EN 15408:2011 | PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","parameters_zh":[{"name":"范围","range":"(0,1 – 10,0) %"}],"search_zh":"氟含量 离子色谱-电导检测法（IC-CD） 范围 PN-EN 15408:2011 | PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","methodology_zh":"氟含量"},{"_id":"6a832b7f884ede9a1b2c55c8","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady kod: 17 05 04,19 01 12 19 12 10, 19 12 12; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość telluru","parameters":[{"name":"Zakres","range":"(5,0 – 100) mg/kg"},{"name":"Spektrometria mas sprzężona z plazmą wzbudzaną indukcyjnie (ICP-MS)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość telluru\nZakres:\nZakres (5,0 – 100) mg/kg\nSpektrometria mas sprzężona z plazmą wzbudzaną indukcyjnie (ICP-MS)","reference":"PN-EN 13657:2006; | PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN 13657:2006;","PN-EN ISO 17294-2:2024-04"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady kod: 17 05 04,19 01 12 19 12 10, 19 12 12; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość telluru\nZakres:\nZakres (5,0 – 100) mg/kg\nSpektrometria mas sprzężona z plazmą wzbudzaną indukcyjnie (ICP-MS) PN-EN 13657:2006; | PN-EN ISO 17294-2:2024-04 Odpady kod: 17 05 04,19 01 12 19 12 10, 19 12 12; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc telluru\nZakres:\nZakres (5,0 – 100) mg/kg\nSpektrometria mas sprzezona z plazma wzbudzana indukcyjnie (ICP-MS) PN-EN 13657:2006; | PN-EN ISO 17294-2:2024-04","categories":["environment"],"row_index":256,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Tellurium content","parameters_en":[{"name":"Range","range":"(5,0 – 100) mg/kg"},{"name":"Inductively coupled plasma mass spectrometry (ICP-MS)"}],"search_en":"Tellurium content Range Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN 13657:2006; | PN-EN ISO 17294-2:2024-04","parameters_zh":[{"name":"范围","range":"(5,0 – 100) mg/kg"},{"name":"Spektrometria mas sprzężona z plazmą wzbudzaną indukcyjnie (ICP-MS)"}],"search_zh":"范围 PN-EN 13657:2006; | PN-EN ISO 17294-2:2024-04"},{"_id":"6a832b7f884ede9a1b2c55c9","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Wyciągi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(5 – 50000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (5 – 50000) μS/cm\nMetoda konduktometryczna","reference":"DIN 19529:2015-12 | PN-EN 27888:1999","norm_bases":["DIN 19529:2015-12","PN-EN 27888:1999"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyciągi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Przewodność elektryczna właściwa\nZakres (5 – 50000) μS/cm\nMetoda konduktometryczna DIN 19529:2015-12 | PN-EN 27888:1999 Wyciagi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Przewodnosc elektryczna wlasciwa\nZakres (5 – 50000) μS/cm\nMetoda konduktometryczna DIN 19529:2015-12 | PN-EN 27888:1999","categories":["environment"],"row_index":257,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(5 – 50000) μS/cm"}],"search_en":"Electrical conductivity Conductometric method Range DIN 19529:2015-12 | PN-EN 27888:1999","technique_en":"Conductometric method","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(5 – 50000) μS/cm"}],"search_zh":"电导率 电导法 范围 DIN 19529:2015-12 | PN-EN 27888:1999","technique_zh":"电导法"},{"_id":"6a832b7f884ede9a1b2c55ca","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Wyciągi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"DIN 19529:2015-12 | PN-EN ISO 10523:2012","norm_bases":["DIN 19529:2015-12","PN-EN ISO 10523:2012"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyciągi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna DIN 19529:2015-12 | PN-EN ISO 10523:2012 Wyciagi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna DIN 19529:2015-12 | PN-EN ISO 10523:2012","categories":["environment"],"row_index":258,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"pH Potentiometric method Range DIN 19529:2015-12 | PN-EN ISO 10523:2012","technique_en":"Potentiometric method","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"pH 值 电位法 范围 DIN 19529:2015-12 | PN-EN ISO 10523:2012","technique_zh":"电位法"},{"_id":"6a832b7f884ede9a1b2c55cb","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Wyciągi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Stężenie anionów","parameters":[{"name":"Siarczany","range":"(2,0 – 500) mg/l"},{"name":"Chlorki","range":"(2,0 – 300) mg/l"},{"name":"Fluorki","range":"(0,10 – 2,0) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nSiarczany (2,0 – 500) mg/l\nChlorki (2,0 – 300) mg/l\nFluorki (0,10 – 2,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"DIN 19529:2015-12 | PN-EN ISO 10304-1:2009","norm_bases":["DIN 19529:2015-12","PN-EN ISO 10304-1:2009"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyciągi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Stężenie anionów\nZakres:\nSiarczany (2,0 – 500) mg/l\nChlorki (2,0 – 300) mg/l\nFluorki (0,10 – 2,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) DIN 19529:2015-12 | PN-EN ISO 10304-1:2009 Wyciagi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Stezenie anionow\nZakres:\nSiarczany (2,0 – 500) mg/l\nChlorki (2,0 – 300) mg/l\nFluorki (0,10 – 2,0) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) DIN 19529:2015-12 | PN-EN ISO 10304-1:2009","categories":["environment"],"row_index":259,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Sulfates","range":"(2,0 – 500) mg/l"},{"name":"Chlorides","range":"(2,0 – 300) mg/l"},{"name":"Fluorides","range":"(0,10 – 2,0) mg/l"}],"search_en":"Anion concentrations Ion chromatography with conductometric detection (IC-CD) Sulfates Chlorides Fluorides DIN 19529:2015-12 | PN-EN ISO 10304-1:2009","technique_en":"Ion chromatography with conductometric detection (IC-CD)","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"硫酸盐","range":"(2,0 – 500) mg/l"},{"name":"氯化物","range":"(2,0 – 300) mg/l"},{"name":"氟化物","range":"(0,10 – 2,0) mg/l"}],"search_zh":"阴离子浓度 离子色谱-电导检测法（IC-CD） 硫酸盐 氯化物 氟化物 DIN 19529:2015-12 | PN-EN ISO 10304-1:2009","technique_zh":"离子色谱-电导检测法（IC-CD）"},{"_id":"6a832b7f884ede9a1b2c55cc","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość anionów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość anionów (z obliczeń)","reference":"DIN 19529:2015-12 | PN-EN ISO 10304-1:2009","norm_bases":["DIN 19529:2015-12","PN-EN ISO 10304-1:2009"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość anionów (z obliczeń) DIN 19529:2015-12 | PN-EN ISO 10304-1:2009 Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc anionow (z obliczen) DIN 19529:2015-12 | PN-EN ISO 10304-1:2009","categories":["environment"],"row_index":260,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion content (calculated)","search_en":"Anion content (calculated) DIN 19529:2015-12 | PN-EN ISO 10304-1:2009","methodology_zh":"阴离子含量（由计算得出）","search_zh":"阴离子含量（由计算得出） DIN 19529:2015-12 | PN-EN ISO 10304-1:2009"},{"_id":"6a832b7f884ede9a1b2c55cd","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Wyciągi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Stężenie polichlorowanych bifenyli (PCB)","parameters":[{"name":"PCB 28","range":"(0,0010 – 1,0) μg/l"},{"name":"PCB 52","range":"(0,0010 – 1,0) μg/l"},{"name":"PCB 101","range":"(0,0010 – 1,0) μg/l"},{"name":"PCB 118","range":"(0,0010 – 1,0) μg/l"},{"name":"PCB 138","range":"(0,0010 – 1,0) μg/l"},{"name":"PCB 153","range":"(0,0010 – 1,0) μg/l"},{"name":"PCB 180","range":"(0,0010 – 1,0) μg/l"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,0010 – 1,0) μg/l\nPCB 52 (0,0010 – 1,0) μg/l\nPCB 101 (0,0010 – 1,0) μg/l\nPCB 118 (0,0010 – 1,0) μg/l\nPCB 138 (0,0010 – 1,0) μg/l\nPCB 153 (0,0010 – 1,0) μg/l\nPCB 180 (0,0010 – 1,0) μg/l\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"DIN 19529:2015-12 | DIN 38407-37:2013-11","norm_bases":["DIN 19529:2015-12","DIN 38407-37:2013-11"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyciągi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Stężenie polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,0010 – 1,0) μg/l\nPCB 52 (0,0010 – 1,0) μg/l\nPCB 101 (0,0010 – 1,0) μg/l\nPCB 118 (0,0010 – 1,0) μg/l\nPCB 138 (0,0010 – 1,0) μg/l\nPCB 153 (0,0010 – 1,0) μg/l\nPCB 180 (0,0010 – 1,0) μg/l\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) DIN 19529:2015-12 | DIN 38407-37:2013-11 Wyciagi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Stezenie polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,0010 – 1,0) μg/l\nPCB 52 (0,0010 – 1,0) μg/l\nPCB 101 (0,0010 – 1,0) μg/l\nPCB 118 (0,0010 – 1,0) μg/l\nPCB 138 (0,0010 – 1,0) μg/l\nPCB 153 (0,0010 – 1,0) μg/l\nPCB 180 (0,0010 – 1,0) μg/l\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) DIN 19529:2015-12 | DIN 38407-37:2013-11","categories":["environment"],"row_index":261,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polychlorinated biphenyls (PCB) concentration","parameters_en":[{"name":"PCB 28","range":"(0,0010 – 1,0) μg/l"},{"name":"PCB 52","range":"(0,0010 – 1,0) μg/l"},{"name":"PCB 101","range":"(0,0010 – 1,0) μg/l"},{"name":"PCB 118","range":"(0,0010 – 1,0) μg/l"},{"name":"PCB 138","range":"(0,0010 – 1,0) μg/l"},{"name":"PCB 153","range":"(0,0010 – 1,0) μg/l"},{"name":"PCB 180","range":"(0,0010 – 1,0) μg/l"}],"search_en":"Polychlorinated biphenyls (PCB) concentration Gas chromatography with mass spectrometry detection (GC-MS) PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 DIN 19529:2015-12 | DIN 38407-37:2013-11","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","search_zh":"多氯联苯（PCB）浓度 气相色谱-质谱法（GC-MS） PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 DIN 19529:2015-12 | DIN 38407-37:2013-11","technique_zh":"气相色谱-质谱法（GC-MS）","parameters_zh":[{"name":"PCB 28","range":"(0,0010 – 1,0) μg/l"},{"name":"PCB 52","range":"(0,0010 – 1,0) μg/l"},{"name":"PCB 101","range":"(0,0010 – 1,0) μg/l"},{"name":"PCB 118","range":"(0,0010 – 1,0) μg/l"},{"name":"PCB 138","range":"(0,0010 – 1,0) μg/l"},{"name":"PCB 153","range":"(0,0010 – 1,0) μg/l"},{"name":"PCB 180","range":"(0,0010 – 1,0) μg/l"}],"methodology_zh":"多氯联苯（PCB）浓度"},{"_id":"6a832b7f884ede9a1b2c55ce","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość polichlorowanych bifenyli (PCB) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość polichlorowanych bifenyli (PCB) (z obliczeń)","reference":"DIN 19529:2015-12 | DIN 38407-37:2013-11","norm_bases":["DIN 19529:2015-12","DIN 38407-37:2013-11"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość polichlorowanych bifenyli (PCB) (z obliczeń) DIN 19529:2015-12 | DIN 38407-37:2013-11 Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc polichlorowanych bifenyli (PCB) (z obliczen) DIN 19529:2015-12 | DIN 38407-37:2013-11","categories":["environment"],"row_index":262,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of polychlorinated biphenyls (PCB) (calculated)","search_en":"Content of polychlorinated biphenyls (PCB) (calculated) DIN 19529:2015-12 | DIN 38407-37:2013-11"},{"_id":"6a832b7f884ede9a1b2c55cf","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Wyciągi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,00010 - 5,00) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,00010 - 5,00) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"DIN 19529:2015-12 | PN-EN ISO 12846:2012 +Ap1:2016-07","norm_bases":["DIN 19529:2015-12","PN-EN ISO 12846:2012 +Ap1:2016-07"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyciągi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Stężenie rtęci\nZakres (0,00010 - 5,00) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) DIN 19529:2015-12 | PN-EN ISO 12846:2012 +Ap1:2016-07 Wyciagi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Stezenie rteci\nZakres (0,00010 - 5,00) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) DIN 19529:2015-12 | PN-EN ISO 12846:2012 +Ap1:2016-07","categories":["environment"],"row_index":263,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,00010 - 5,00) mg/l"}],"search_en":"Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range DIN 19529:2015-12 | PN-EN ISO 12846:2012 +Ap1:2016-07","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,00010 - 5,00) mg/l"}],"search_zh":"汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 DIN 19529:2015-12 | PN-EN ISO 12846:2012 +Ap1:2016-07","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a832b7f884ede9a1b2c55d0","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość rtęci (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość rtęci (z obliczeń)","reference":"DIN 19529:2015-12 | PN-EN ISO 12846:2012 +Ap1:2016-07","norm_bases":["DIN 19529:2015-12","PN-EN ISO 12846:2012 +Ap1:2016-07"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość rtęci (z obliczeń) DIN 19529:2015-12 | PN-EN ISO 12846:2012 +Ap1:2016-07 Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc rteci (z obliczen) DIN 19529:2015-12 | PN-EN ISO 12846:2012 +Ap1:2016-07","categories":["environment"],"row_index":264,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content (calculated)","search_en":"Mercury content (calculated) DIN 19529:2015-12 | PN-EN ISO 12846:2012 +Ap1:2016-07","methodology_zh":"汞含量（由计算得出）","search_zh":"汞含量（由计算得出） DIN 19529:2015-12 | PN-EN ISO 12846:2012 +Ap1:2016-07"},{"_id":"6a832b7f884ede9a1b2c55d1","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Wyciągi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"Zakres","range":"1-metylonaftalen (0,0050 – 1,0) μg/l"},{"name":"2-metylonaftalen","range":"(0,0050 – 1,0) μg/l"},{"name":"naftalen","range":"(0,0050 – 1,0) μg/l"},{"name":"antracen","range":"(0,0050 – 1,0) μg/l"},{"name":"chryzen","range":"(0,0050 – 1,0) μg/l"},{"name":"benzo(a)antracen","range":"(0,0050 – 1,0) μg/l"},{"name":"dibenzo(a,h)antracen","range":"(0,0050 – 1,0) μg/l"},{"name":"benzo(a)piren","range":"(0,0050 – 1,0) μg/l"},{"name":"benzo(b)fluoranten","range":"(0,0050 – 1,0) μg/l"},{"name":"benzo(k)fluoranten","range":"(0,0050 – 1,0) μg/l"},{"name":"benzo(ghi)perylen","range":"(0,0050 – 1,0) μg/l"},{"name":"indeno","range":"(1,2,3-cd)piren"},{"name":"(0,0050 – 1,0) μg/l"},{"name":"acenaften","range":"(0,0050 – 1,0) μg/l"},{"name":"acenaftylen","range":"(0,0050 – 1,0) μg/l"},{"name":"fluoranten","range":"(0,0050 – 1,0) μg/l"},{"name":"fluoren","range":"(0,0050 – 1,0) μg/l"},{"name":"fenantren","range":"(0,0050 – 1,0) μg/l"},{"name":"piren","range":"(0,0050 – 1,0) μg/l"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nZakres 1-metylonaftalen (0,0050 – 1,0) μg/l\n2-metylonaftalen (0,0050 – 1,0) μg/l\nnaftalen (0,0050 – 1,0) μg/l\nantracen (0,0050 – 1,0) μg/l\nchryzen (0,0050 – 1,0) μg/l\nbenzo(a)antracen (0,0050 – 1,0) μg/l\ndibenzo(a,h)antracen (0,0050 – 1,0) μg/l\nbenzo(a)piren (0,0050 – 1,0) μg/l\nbenzo(b)fluoranten (0,0050 – 1,0) μg/l\nbenzo(k)fluoranten (0,0050 – 1,0) μg/l\nbenzo(ghi)perylen (0,0050 – 1,0) μg/l\nindeno (1,2,3-cd)piren\n(0,0050 – 1,0) μg/l\nacenaften (0,0050 – 1,0) μg/l\nacenaftylen (0,0050 – 1,0) μg/l\nfluoranten (0,0050 – 1,0) μg/l\nfluoren (0,0050 – 1,0) μg/l\nfenantren (0,0050 – 1,0) μg/l\npiren (0,0050 – 1,0) μg/l\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"DIN 19529:2015-12 | DIN 38407-39: 2011-09","norm_bases":["DIN 19529:2015-12","DIN 38407-39: 2011-09"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyciągi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nZakres 1-metylonaftalen (0,0050 – 1,0) μg/l\n2-metylonaftalen (0,0050 – 1,0) μg/l\nnaftalen (0,0050 – 1,0) μg/l\nantracen (0,0050 – 1,0) μg/l\nchryzen (0,0050 – 1,0) μg/l\nbenzo(a)antracen (0,0050 – 1,0) μg/l\ndibenzo(a,h)antracen (0,0050 – 1,0) μg/l\nbenzo(a)piren (0,0050 – 1,0) μg/l\nbenzo(b)fluoranten (0,0050 – 1,0) μg/l\nbenzo(k)fluoranten (0,0050 – 1,0) μg/l\nbenzo(ghi)perylen (0,0050 – 1,0) μg/l\nindeno (1,2,3-cd)piren\n(0,0050 – 1,0) μg/l\nacenaften (0,0050 – 1,0) μg/l\nacenaftylen (0,0050 – 1,0) μg/l\nfluoranten (0,0050 – 1,0) μg/l\nfluoren (0,0050 – 1,0) μg/l\nfenantren (0,0050 – 1,0) μg/l\npiren (0,0050 – 1,0) μg/l\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) DIN 19529:2015-12 | DIN 38407-39: 2011-09 Wyciagi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nZakres 1-metylonaftalen (0,0050 – 1,0) μg/l\n2-metylonaftalen (0,0050 – 1,0) μg/l\nnaftalen (0,0050 – 1,0) μg/l\nantracen (0,0050 – 1,0) μg/l\nchryzen (0,0050 – 1,0) μg/l\nbenzo(a)antracen (0,0050 – 1,0) μg/l\ndibenzo(a,h)antracen (0,0050 – 1,0) μg/l\nbenzo(a)piren (0,0050 – 1,0) μg/l\nbenzo(b)fluoranten (0,0050 – 1,0) μg/l\nbenzo(k)fluoranten (0,0050 – 1,0) μg/l\nbenzo(ghi)perylen (0,0050 – 1,0) μg/l\nindeno (1,2,3-cd)piren\n(0,0050 – 1,0) μg/l\nacenaften (0,0050 – 1,0) μg/l\nacenaftylen (0,0050 – 1,0) μg/l\nfluoranten (0,0050 – 1,0) μg/l\nfluoren (0,0050 – 1,0) μg/l\nfenantren (0,0050 – 1,0) μg/l\npiren (0,0050 – 1,0) μg/l\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) DIN 19529:2015-12 | DIN 38407-39: 2011-09","categories":["environment"],"row_index":265,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","parameters_en":[{"name":"Range","range":"1-metylonaftalen (0,0050 – 1,0) μg/l"},{"name":"2-methylnaphthalene","range":"(0,0050 – 1,0) μg/l"},{"name":"naphthalene","range":"(0,0050 – 1,0) μg/l"},{"name":"anthracene","range":"(0,0050 – 1,0) μg/l"},{"name":"chrysene","range":"(0,0050 – 1,0) μg/l"},{"name":"benzo(a)anthracene","range":"(0,0050 – 1,0) μg/l"},{"name":"dibenzo(a,h)anthracene","range":"(0,0050 – 1,0) μg/l"},{"name":"benzo(a)pyrene","range":"(0,0050 – 1,0) μg/l"},{"name":"benzo(b)fluoranthene","range":"(0,0050 – 1,0) μg/l"},{"name":"benzo(k)fluoranthene","range":"(0,0050 – 1,0) μg/l"},{"name":"benzo(ghi)perylene","range":"(0,0050 – 1,0) μg/l"},{"name":"indeno","range":"(1,2,3-cd)piren"},{"name":"(0,0050 – 1,0) μg/l"},{"name":"acenaphthene","range":"(0,0050 – 1,0) μg/l"},{"name":"acenaphthylene","range":"(0,0050 – 1,0) μg/l"},{"name":"fluoranthene","range":"(0,0050 – 1,0) μg/l"},{"name":"fluorene","range":"(0,0050 – 1,0) μg/l"},{"name":"phenanthrene","range":"(0,0050 – 1,0) μg/l"},{"name":"pyrene","range":"(0,0050 – 1,0) μg/l"}],"search_en":"Concentration of polycyclic aromatic hydrocarbons (PAH) Gas chromatography with mass spectrometry detection (GC-MS) Range 2-methylnaphthalene naphthalene anthracene chrysene benzo(a)anthracene dibenzo(a,h)anthracene benzo(a)pyrene benzo(b)fluoranthene benzo(k)fluoranthene benzo(ghi)perylene indeno (0,0050 – 1,0) μg/l acenaphthene acenaphthylene fluoranthene fluorene phenanthrene pyrene DIN 19529:2015-12 | DIN 38407-39: 2011-09","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","parameters_zh":[{"name":"范围","range":"1-metylonaftalen (0,0050 – 1,0) μg/l"},{"name":"2-metylonaftalen","range":"(0,0050 – 1,0) μg/l"},{"name":"萘","range":"(0,0050 – 1,0) μg/l"},{"name":"蒽","range":"(0,0050 – 1,0) μg/l"},{"name":"䓛","range":"(0,0050 – 1,0) μg/l"},{"name":"苯并（a）蒽","range":"(0,0050 – 1,0) μg/l"},{"name":"二苯并（a,h）蒽","range":"(0,0050 – 1,0) μg/l"},{"name":"苯并（a）芘","range":"(0,0050 – 1,0) μg/l"},{"name":"苯并（b）荧蒽","range":"(0,0050 – 1,0) μg/l"},{"name":"苯并（k）荧蒽","range":"(0,0050 – 1,0) μg/l"},{"name":"苯并（ghi）苝","range":"(0,0050 – 1,0) μg/l"},{"name":"茚","range":"(1,2,3-cd)piren"},{"name":"(0,0050 – 1,0) μg/l"},{"name":"苊","range":"(0,0050 – 1,0) μg/l"},{"name":"苊烯","range":"(0,0050 – 1,0) μg/l"},{"name":"荧蒽","range":"(0,0050 – 1,0) μg/l"},{"name":"芴","range":"(0,0050 – 1,0) μg/l"},{"name":"菲","range":"(0,0050 – 1,0) μg/l"},{"name":"芘","range":"(0,0050 – 1,0) μg/l"}],"search_zh":"多环芳烃（PAHs）浓度 气相色谱-质谱法（GC-MS） 范围 萘 蒽 䓛 苯并（a）蒽 二苯并（a,h）蒽 苯并（a）芘 苯并（b）荧蒽 苯并（k）荧蒽 苯并（ghi）苝 茚 苊 苊烯 荧蒽 芴 菲 芘 DIN 19529:2015-12 | DIN 38407-39: 2011-09","technique_zh":"气相色谱-质谱法（GC-MS）","methodology_zh":"多环芳烃（PAHs）浓度"},{"_id":"6a832b7f884ede9a1b2c55d2","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)","reference":"DIN 19529:2015-12 | DIN 38407-39: 2011-09","norm_bases":["DIN 19529:2015-12","DIN 38407-39: 2011-09"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń) DIN 19529:2015-12 | DIN 38407-39: 2011-09 Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA) (z obliczen) DIN 19529:2015-12 | DIN 38407-39: 2011-09","categories":["environment"],"row_index":266,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of polycyclic aromatic hydrocarbons (PAH) (calculated)","search_en":"Content of polycyclic aromatic hydrocarbons (PAH) (calculated) DIN 19529:2015-12 | DIN 38407-39: 2011-09"},{"_id":"6a832b7f884ede9a1b2c55d3","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Wyciągi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Stężenie pierwiastków","parameters":[{"name":"arsen","range":"(0,0005 – 10,0) mg/l"},{"name":"bar","range":"(0,0010 – 10,0) mg/l"},{"name":"chrom","range":"(0,0010 – 10,0) mg/l"},{"name":"cynk","range":"(0,010 – 20,0) mg/l"},{"name":"kadm","range":"(0,00030 – 10,0) mg/l"},{"name":"miedź","range":"(0,0010 – 10,0) mg/l"},{"name":"nikiel","range":"(0,0010 – 10,0) mg/l"},{"name":"rtęć","range":"(0,00010 – 10,0) mg/l"},{"name":"tal","range":"(0,00020 – 10,0) mg/l"},{"name":"wanad","range":"(0,0010 – 10,0) mg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\narsen (0,0005 – 10,0) mg/l\nbar (0,0010 – 10,0) mg/l\nchrom (0,0010 – 10,0) mg/l\ncynk (0,010 – 20,0) mg/l\nkadm (0,00030 – 10,0) mg/l\nmiedź (0,0010 – 10,0) mg/l\nnikiel (0,0010 – 10,0) mg/l\nrtęć (0,00010 – 10,0) mg/l\ntal (0,00020 – 10,0) mg/l\nwanad (0,0010 – 10,0) mg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"DIN 19529:2015-12 | PN-EN ISO 17294-2:2016-11","norm_bases":["DIN 19529:2015-12","PN-EN ISO 17294-2:2016-11"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyciągi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Stężenie pierwiastków\nZakres:\narsen (0,0005 – 10,0) mg/l\nbar (0,0010 – 10,0) mg/l\nchrom (0,0010 – 10,0) mg/l\ncynk (0,010 – 20,0) mg/l\nkadm (0,00030 – 10,0) mg/l\nmiedź (0,0010 – 10,0) mg/l\nnikiel (0,0010 – 10,0) mg/l\nrtęć (0,00010 – 10,0) mg/l\ntal (0,00020 – 10,0) mg/l\nwanad (0,0010 – 10,0) mg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) DIN 19529:2015-12 | PN-EN ISO 17294-2:2016-11 Wyciagi wodne: Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Stezenie pierwiastkow\nZakres:\narsen (0,0005 – 10,0) mg/l\nbar (0,0010 – 10,0) mg/l\nchrom (0,0010 – 10,0) mg/l\ncynk (0,010 – 20,0) mg/l\nkadm (0,00030 – 10,0) mg/l\nmiedz (0,0010 – 10,0) mg/l\nnikiel (0,0010 – 10,0) mg/l\nrtec (0,00010 – 10,0) mg/l\ntal (0,00020 – 10,0) mg/l\nwanad (0,0010 – 10,0) mg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) DIN 19529:2015-12 | PN-EN ISO 17294-2:2016-11","categories":["environment","materials"],"row_index":267,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"arsenic","range":"(0,0005 – 10,0) mg/l"},{"name":"barium","range":"(0,0010 – 10,0) mg/l"},{"name":"chromium","range":"(0,0010 – 10,0) mg/l"},{"name":"zinc","range":"(0,010 – 20,0) mg/l"},{"name":"cadmium","range":"(0,00030 – 10,0) mg/l"},{"name":"copper","range":"(0,0010 – 10,0) mg/l"},{"name":"nickel","range":"(0,0010 – 10,0) mg/l"},{"name":"mercury","range":"(0,00010 – 10,0) mg/l"},{"name":"thallium","range":"(0,00020 – 10,0) mg/l"},{"name":"vanadium","range":"(0,0010 – 10,0) mg/l"}],"search_en":"Element concentration Inductively coupled plasma mass spectrometry (ICP-MS) arsenic barium chromium zinc cadmium copper nickel mercury thallium vanadium DIN 19529:2015-12 | PN-EN ISO 17294-2:2016-11","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","methodology_zh":"元素浓度","parameters_zh":[{"name":"砷","range":"(0,0005 – 10,0) mg/l"},{"name":"钡","range":"(0,0010 – 10,0) mg/l"},{"name":"铬","range":"(0,0010 – 10,0) mg/l"},{"name":"锌","range":"(0,010 – 20,0) mg/l"},{"name":"镉","range":"(0,00030 – 10,0) mg/l"},{"name":"铜","range":"(0,0010 – 10,0) mg/l"},{"name":"镍","range":"(0,0010 – 10,0) mg/l"},{"name":"汞","range":"(0,00010 – 10,0) mg/l"},{"name":"铊","range":"(0,00020 – 10,0) mg/l"},{"name":"钒","range":"(0,0010 – 10,0) mg/l"}],"search_zh":"元素浓度 电感耦合等离子体质谱法（ICP-MS） 砷 钡 铬 锌 镉 铜 镍 汞 铊 钒 DIN 19529:2015-12 | PN-EN ISO 17294-2:2016-11","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a832b7f884ede9a1b2c55d4","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość pierwiastków (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość pierwiastków (z obliczeń)","reference":"DIN 19529:2015-12 | PN-EN ISO 17294-2:2016-11","norm_bases":["DIN 19529:2015-12","PN-EN ISO 17294-2:2016-11"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość pierwiastków (z obliczeń) DIN 19529:2015-12 | PN-EN ISO 17294-2:2016-11 Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc pierwiastkow (z obliczen) DIN 19529:2015-12 | PN-EN ISO 17294-2:2016-11","categories":["environment"],"row_index":268,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content (calculated)","search_en":"Element content (calculated) DIN 19529:2015-12 | PN-EN ISO 17294-2:2016-11","methodology_zh":"元素含量（由计算得出）","search_zh":"元素含量（由计算得出） DIN 19529:2015-12 | PN-EN ISO 17294-2:2016-11"},{"_id":"6a832b7f884ede9a1b2c55d5","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Oleje pochodzenia węglowego","methodology":"Zawartość benzo(a)pirenu","parameters":[{"name":"Zakres","range":"(0,50 – 200) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość benzo(a)pirenu\nZakres (0,50 – 200) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-EN 1014-3:2012","norm_bases":["PN-EN 1014-3:2012"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oleje pochodzenia węglowego Zawartość benzo(a)pirenu\nZakres (0,50 – 200) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-EN 1014-3:2012 Oleje pochodzenia weglowego Zawartosc benzo(a)pirenu\nZakres (0,50 – 200) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-EN 1014-3:2012","categories":["petro"],"row_index":269,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Benzo(a)pyrene content","parameters_en":[{"name":"Range","range":"(0,50 – 200) mg/kg"}],"search_en":"Coal-derived oils Benzo(a)pyrene content High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Range PN-EN 1014-3:2012","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Coal-derived oils","parameters_zh":[{"name":"范围","range":"(0,50 – 200) mg/kg"}],"search_zh":"苯并(a)芘含量 高效液相色谱-荧光检测法（HPLC-FLD） 范围 PN-EN 1014-3:2012","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","methodology_zh":"苯并(a)芘含量"},{"_id":"6a832b7f884ede9a1b2c55d6","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady czynne","methodology":"Indeks gęstości osadu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks gęstości osadu (z obliczeń)","reference":"PN-EN 14702-1:2008","norm_bases":["PN-EN 14702-1:2008"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady czynne Indeks gęstości osadu (z obliczeń) PN-EN 14702-1:2008 Osady czynne Indeks gestosci osadu (z obliczen) PN-EN 14702-1:2008","categories":["water"],"row_index":270,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sludge density index (calculated)","search_en":"Activated sludge Sludge density index (calculated) PN-EN 14702-1:2008","test_object_en":"Activated sludge","search_zh":"活性污泥 PN-EN 14702-1:2008","test_object_zh":"活性污泥"},{"_id":"6a832b7f884ede9a1b2c55d7","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady czynne","methodology":"Indeks objętościowy osadu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks objętościowy osadu (z obliczeń)","reference":"PN-EN 14702-1:2008","norm_bases":["PN-EN 14702-1:2008"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady czynne Indeks objętościowy osadu (z obliczeń) PN-EN 14702-1:2008 Osady czynne Indeks objetosciowy osadu (z obliczen) PN-EN 14702-1:2008","categories":["water"],"row_index":271,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sludge volume index (calculated)","search_en":"Activated sludge Sludge volume index (calculated) PN-EN 14702-1:2008","test_object_en":"Activated sludge","search_zh":"活性污泥 污泥容积指数（由计算得出） PN-EN 14702-1:2008","test_object_zh":"活性污泥","methodology_zh":"污泥容积指数（由计算得出）"},{"_id":"6a832b7f884ede9a1b2c55d8","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady czynne","methodology":"Zawiesiny łatwoopadające (zdolność opadania osadu)","parameters":[{"name":"Zakres","range":"(100 – 1000) ml/l"}],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Zawiesiny łatwoopadające (zdolność opadania osadu)\nZakres (100 – 1000) ml/l\nMetoda objętościowa","reference":"PN-EN 14702-1:2008","norm_bases":["PN-EN 14702-1:2008"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady czynne Zawiesiny łatwoopadające (zdolność opadania osadu)\nZakres (100 – 1000) ml/l\nMetoda objętościowa PN-EN 14702-1:2008 Osady czynne Zawiesiny latwoopadajace (zdolnosc opadania osadu)\nZakres (100 – 1000) ml/l\nMetoda objetosciowa PN-EN 14702-1:2008","categories":["water"],"row_index":272,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Settleable solids (sludge settleability)","parameters_en":[{"name":"Range","range":"(100 – 1000) ml/l"}],"search_en":"Activated sludge Settleable solids (sludge settleability) Volumetric method Range PN-EN 14702-1:2008","technique_en":"Volumetric method","test_object_en":"Activated sludge","parameters_zh":[{"name":"范围","range":"(100 – 1000) ml/l"}],"search_zh":"活性污泥 容量法 范围 PN-EN 14702-1:2008","technique_zh":"容量法","test_object_zh":"活性污泥"},{"_id":"6a832b7f884ede9a1b2c55d9","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady czynne","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(1000 – 20000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (1000 – 20000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady czynne Zawiesiny ogólne\nZakres (1000 – 20000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Osady czynne Zawiesiny ogolne\nZakres (1000 – 20000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":273,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(1000 – 20000) mg/l"}],"search_en":"Activated sludge Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Activated sludge","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(1000 – 20000) mg/l"}],"search_zh":"活性污泥 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"活性污泥"},{"_id":"6a832b7f884ede9a1b2c55da","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady denne","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady denne pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":274,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Bottom sediments pH Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Bottom sediments","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"底泥 pH 值 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"底泥"},{"_id":"6a832b7f884ede9a1b2c55db","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady denne","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10,0 – 8000) μS/cm"},{"name":"Zakres","range":"(1,0 – 800) mS/m"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres:\nZakres (10,0 – 8000) μS/cm\nZakres (1,0 – 800) mS/m\nMetoda konduktometryczna","reference":"PN-ISO 11265+AC1:1997","norm_bases":["PN-ISO 11265+AC1:1997"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne Przewodność elektryczna właściwa\nZakres:\nZakres (10,0 – 8000) μS/cm\nZakres (1,0 – 800) mS/m\nMetoda konduktometryczna PN-ISO 11265+AC1:1997 Osady denne Przewodnosc elektryczna wlasciwa\nZakres:\nZakres (10,0 – 8000) μS/cm\nZakres (1,0 – 800) mS/m\nMetoda konduktometryczna PN-ISO 11265+AC1:1997","categories":["water"],"row_index":275,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10,0 – 8000) μS/cm"},{"name":"Range","range":"(1,0 – 800) mS/m"}],"search_en":"Bottom sediments Electrical conductivity Conductometric method Range Range PN-ISO 11265+AC1:1997","technique_en":"Conductometric method","test_object_en":"Bottom sediments","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10,0 – 8000) μS/cm"},{"name":"范围","range":"(1,0 – 800) mS/m"}],"search_zh":"底泥 电导率 电导法 范围 范围 PN-ISO 11265+AC1:1997","technique_zh":"电导法","test_object_zh":"底泥"},{"_id":"6a832b7f884ede9a1b2c55dc","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady denne","methodology":"Zawartość fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,001 – 0,10) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu ogólnego\nZakres (0,001 – 0,10) %\nMetoda spektrofotometryczna","reference":"PN-EN 14672:2006","norm_bases":["PN-EN 14672:2006"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne Zawartość fosforu ogólnego\nZakres (0,001 – 0,10) %\nMetoda spektrofotometryczna PN-EN 14672:2006 Osady denne Zawartosc fosforu ogolnego\nZakres (0,001 – 0,10) %\nMetoda spektrofotometryczna PN-EN 14672:2006","categories":["water"],"row_index":276,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus content","parameters_en":[{"name":"Range","range":"(0,001 – 0,10) %"}],"search_en":"Bottom sediments Total phosphorus content Spectrophotometric method Range PN-EN 14672:2006","technique_en":"Spectrophotometric method","test_object_en":"Bottom sediments","parameters_zh":[{"name":"范围","range":"(0,001 – 0,10) %"}],"search_zh":"底泥 总磷含量 分光光度法 范围 PN-EN 14672:2006","technique_zh":"分光光度法","methodology_zh":"总磷含量","test_object_zh":"底泥"},{"_id":"6a832b7f884ede9a1b2c55dd","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady denne","methodology":"Zawartość polichlorowanych bifenyli (PCB)","parameters":[{"name":"PCB 28","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 52","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 101","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 118","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 138","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 153","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 180","range":"(0,020 – 2,5) mg/kg"},{"name":"Suma polichlorowanych bifenyli (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,020 – 2,5) mg/kg\nPCB 52 (0,020 – 2,5) mg/kg\nPCB 101 (0,020 – 2,5) mg/kg\nPCB 118 (0,020 – 2,5) mg/kg\nPCB 138 (0,020 – 2,5) mg/kg\nPCB 153 (0,020 – 2,5) mg/kg\nPCB 180 (0,020 – 2,5) mg/kg\nSuma polichlorowanych bifenyli (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"EFO/PB/43/B:05.09.2025","norm_bases":["EFO/PB/43/B:05.09.2025"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne Zawartość polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,020 – 2,5) mg/kg\nPCB 52 (0,020 – 2,5) mg/kg\nPCB 101 (0,020 – 2,5) mg/kg\nPCB 118 (0,020 – 2,5) mg/kg\nPCB 138 (0,020 – 2,5) mg/kg\nPCB 153 (0,020 – 2,5) mg/kg\nPCB 180 (0,020 – 2,5) mg/kg\nSuma polichlorowanych bifenyli (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) EFO/PB/43/B:05.09.2025 Osady denne Zawartosc polichlorowanych bifenyli (PCB)\nZakres:\nPCB 28 (0,020 – 2,5) mg/kg\nPCB 52 (0,020 – 2,5) mg/kg\nPCB 101 (0,020 – 2,5) mg/kg\nPCB 118 (0,020 – 2,5) mg/kg\nPCB 138 (0,020 – 2,5) mg/kg\nPCB 153 (0,020 – 2,5) mg/kg\nPCB 180 (0,020 – 2,5) mg/kg\nSuma polichlorowanych bifenyli (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) EFO/PB/43/B:05.09.2025","categories":["water"],"row_index":277,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polychlorinated biphenyls (PCB) content","parameters_en":[{"name":"PCB 28","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 52","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 101","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 118","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 138","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 153","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 180","range":"(0,020 – 2,5) mg/kg"},{"name":"Sum of polychlorinated biphenyls (calculated)"}],"search_en":"Bottom sediments Polychlorinated biphenyls (PCB) content Gas chromatography with mass spectrometry detection (GC-MS) PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 Sum of polychlorinated biphenyls (calculated) EFO/PB/43/B:05.09.2025","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Bottom sediments","search_zh":"底泥 多氯联苯（PCB）含量 气相色谱-质谱法（GC-MS） PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 多氯联苯总量（由计算得出） EFO/PB/43/B:05.09.2025","technique_zh":"气相色谱-质谱法（GC-MS）","parameters_zh":[{"name":"PCB 28","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 52","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 101","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 118","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 138","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 153","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 180","range":"(0,020 – 2,5) mg/kg"},{"name":"多氯联苯总量（由计算得出）"}],"test_object_zh":"底泥","methodology_zh":"多氯联苯（PCB）含量"},{"_id":"6a832b7f884ede9a1b2c55de","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady denne","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych","parameters":[{"name":"naftalen","range":"(0,005 – 100) mg/kg"},{"name":"antracen","range":"(0,005 – 100) mg/kg"},{"name":"chryzen","range":"(0,005 – 100) mg/kg"},{"name":"benzo(a)antracen","range":"(0,005 – 100) mg/kg"},{"name":"dibenzo(a,h)antracen"},{"name":"Zakres","range":"0,005 – 100) mg/kg"},{"name":"benzo(a)piren","range":"(0,005 – 100) mg/kg"},{"name":"benzo(b)fluoranten","range":"(0,005 – 100) mg/kg"},{"name":"benzo(k)fluoranten","range":"(0,005 – 100) mg/kg"},{"name":"benzo(ghi)perylen","range":"(0,005 – 100) mg/kg"},{"name":"indeno","range":"(1,2,3-cd)piren"},{"name":"(0,005 – 100) mg/kg"},{"name":"acenaften","range":"(0,005 – 100) mg/kg"},{"name":"acenaftylen","range":"(0,005 – 100) mg/kg"},{"name":"fluoranten","range":"(0,005 – 100) mg/kg"},{"name":"fluoren","range":"(0,005 – 100) mg/kg"},{"name":"fenantren","range":"(0,005 – 100) mg/kg"},{"name":"piren","range":"(0,005 – 100) mg/kg"},{"name":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych\nZakres:\nnaftalen (0,005 – 100) mg/kg\nantracen (0,005 – 100) mg/kg\nchryzen (0,005 – 100) mg/kg\nbenzo(a)antracen (0,005 – 100) mg/kg\ndibenzo(a,h)antracen\nZakres 0,005 – 100) mg/kg\nbenzo(a)piren (0,005 – 100) mg/kg\nbenzo(b)fluoranten (0,005 – 100) mg/kg\nbenzo(k)fluoranten (0,005 – 100) mg/kg\nbenzo(ghi)perylen (0,005 – 100) mg/kg\nindeno (1,2,3-cd)piren\n(0,005 – 100) mg/kg\nacenaften (0,005 – 100) mg/kg\nacenaftylen (0,005 – 100) mg/kg\nfluoranten (0,005 – 100) mg/kg\nfluoren (0,005 – 100) mg/kg\nfenantren (0,005 – 100) mg/kg\npiren (0,005 – 100) mg/kg\nSuma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"EFO/PB/44/B:05.09.2025","norm_bases":["EFO/PB/44/B:05.09.2025"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne Zawartość wielopierścieniowych węglowodorów aromatycznych\nZakres:\nnaftalen (0,005 – 100) mg/kg\nantracen (0,005 – 100) mg/kg\nchryzen (0,005 – 100) mg/kg\nbenzo(a)antracen (0,005 – 100) mg/kg\ndibenzo(a,h)antracen\nZakres 0,005 – 100) mg/kg\nbenzo(a)piren (0,005 – 100) mg/kg\nbenzo(b)fluoranten (0,005 – 100) mg/kg\nbenzo(k)fluoranten (0,005 – 100) mg/kg\nbenzo(ghi)perylen (0,005 – 100) mg/kg\nindeno (1,2,3-cd)piren\n(0,005 – 100) mg/kg\nacenaften (0,005 – 100) mg/kg\nacenaftylen (0,005 – 100) mg/kg\nfluoranten (0,005 – 100) mg/kg\nfluoren (0,005 – 100) mg/kg\nfenantren (0,005 – 100) mg/kg\npiren (0,005 – 100) mg/kg\nSuma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) EFO/PB/44/B:05.09.2025 Osady denne Zawartosc wielopierscieniowych weglowodorow aromatycznych\nZakres:\nnaftalen (0,005 – 100) mg/kg\nantracen (0,005 – 100) mg/kg\nchryzen (0,005 – 100) mg/kg\nbenzo(a)antracen (0,005 – 100) mg/kg\ndibenzo(a,h)antracen\nZakres 0,005 – 100) mg/kg\nbenzo(a)piren (0,005 – 100) mg/kg\nbenzo(b)fluoranten (0,005 – 100) mg/kg\nbenzo(k)fluoranten (0,005 – 100) mg/kg\nbenzo(ghi)perylen (0,005 – 100) mg/kg\nindeno (1,2,3-cd)piren\n(0,005 – 100) mg/kg\nacenaften (0,005 – 100) mg/kg\nacenaftylen (0,005 – 100) mg/kg\nfluoranten (0,005 – 100) mg/kg\nfluoren (0,005 – 100) mg/kg\nfenantren (0,005 – 100) mg/kg\npiren (0,005 – 100) mg/kg\nSuma wielopierscieniowych weglowodorow aromatycznych (WWA) (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) EFO/PB/44/B:05.09.2025","categories":["water"],"row_index":278,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of polycyclic aromatic hydrocarbons","parameters_en":[{"name":"naphthalene","range":"(0,005 – 100) mg/kg"},{"name":"anthracene","range":"(0,005 – 100) mg/kg"},{"name":"chrysene","range":"(0,005 – 100) mg/kg"},{"name":"benzo(a)anthracene","range":"(0,005 – 100) mg/kg"},{"name":"dibenzo(a,h)anthracene"},{"name":"Range","range":"0,005 – 100) mg/kg"},{"name":"benzo(a)pyrene","range":"(0,005 – 100) mg/kg"},{"name":"benzo(b)fluoranthene","range":"(0,005 – 100) mg/kg"},{"name":"benzo(k)fluoranthene","range":"(0,005 – 100) mg/kg"},{"name":"benzo(ghi)perylene","range":"(0,005 – 100) mg/kg"},{"name":"indeno","range":"(1,2,3-cd)piren"},{"name":"(0,005 – 100) mg/kg"},{"name":"acenaphthene","range":"(0,005 – 100) mg/kg"},{"name":"acenaphthylene","range":"(0,005 – 100) mg/kg"},{"name":"fluoranthene","range":"(0,005 – 100) mg/kg"},{"name":"fluorene","range":"(0,005 – 100) mg/kg"},{"name":"phenanthrene","range":"(0,005 – 100) mg/kg"},{"name":"pyrene","range":"(0,005 – 100) mg/kg"},{"name":"Sum of polycyclic aromatic hydrocarbons (PAH) (calculated)"}],"search_en":"Bottom sediments Content of polycyclic aromatic hydrocarbons Gas chromatography with mass spectrometry detection (GC-MS) naphthalene anthracene chrysene benzo(a)anthracene dibenzo(a,h)anthracene Range benzo(a)pyrene benzo(b)fluoranthene benzo(k)fluoranthene benzo(ghi)perylene indeno (0,005 – 100) mg/kg acenaphthene acenaphthylene fluoranthene fluorene phenanthrene pyrene Sum of polycyclic aromatic hydrocarbons (PAH) (calculated) EFO/PB/44/B:05.09.2025","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Bottom sediments","parameters_zh":[{"name":"萘","range":"(0,005 – 100) mg/kg"},{"name":"蒽","range":"(0,005 – 100) mg/kg"},{"name":"䓛","range":"(0,005 – 100) mg/kg"},{"name":"苯并（a）蒽","range":"(0,005 – 100) mg/kg"},{"name":"二苯并（a,h）蒽"},{"name":"范围","range":"0,005 – 100) mg/kg"},{"name":"苯并（a）芘","range":"(0,005 – 100) mg/kg"},{"name":"苯并（b）荧蒽","range":"(0,005 – 100) mg/kg"},{"name":"苯并（k）荧蒽","range":"(0,005 – 100) mg/kg"},{"name":"苯并（ghi）苝","range":"(0,005 – 100) mg/kg"},{"name":"茚","range":"(1,2,3-cd)piren"},{"name":"(0,005 – 100) mg/kg"},{"name":"苊","range":"(0,005 – 100) mg/kg"},{"name":"苊烯","range":"(0,005 – 100) mg/kg"},{"name":"荧蒽","range":"(0,005 – 100) mg/kg"},{"name":"芴","range":"(0,005 – 100) mg/kg"},{"name":"菲","range":"(0,005 – 100) mg/kg"},{"name":"芘","range":"(0,005 – 100) mg/kg"},{"name":"多环芳烃（PAH）总量（由计算得出）"}],"search_zh":"底泥 多环芳烃含量 气相色谱-质谱法（GC-MS） 萘 蒽 䓛 苯并（a）蒽 二苯并（a,h）蒽 范围 苯并（a）芘 苯并（b）荧蒽 苯并（k）荧蒽 苯并（ghi）苝 茚 苊 苊烯 荧蒽 芴 菲 芘 多环芳烃（PAH）总量（由计算得出） EFO/PB/44/B:05.09.2025","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"底泥","methodology_zh":"多环芳烃含量"},{"_id":"6a832b7f884ede9a1b2c55df","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady denne","methodology":"Zawartość ftalanów","parameters":[{"name":"Ftalan dietylu","range":"(0,05 – 50,0) mg/kg"},{"name":"Ftalan di","range":"(2-etyloheksylu) (DEHP)"},{"name":"Zakres","range":"(0,05 – 50,0)mg/kg"},{"name":"Ftalan benzylu butylu","range":"(0,05 – 50,0) mg/kg"},{"name":"Ftalan diizobutylu","range":"(0,05 – 50,0) mg/kg"},{"name":"Ftalan dibutylu","range":"(0,05 – 50,0) mg/kg"},{"name":"Suma ftalanów (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość ftalanów\nZakres:\nFtalan dietylu (0,05 – 50,0) mg/kg\nFtalan di (2-etyloheksylu) (DEHP)\nZakres (0,05 – 50,0)mg/kg\nFtalan benzylu butylu (0,05 – 50,0) mg/kg\nFtalan diizobutylu (0,05 – 50,0) mg/kg\nFtalan dibutylu (0,05 – 50,0) mg/kg\nSuma ftalanów (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"EFO/PB/41/C:17.09.2025","norm_bases":["EFO/PB/41/C:17.09.2025"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne Zawartość ftalanów\nZakres:\nFtalan dietylu (0,05 – 50,0) mg/kg\nFtalan di (2-etyloheksylu) (DEHP)\nZakres (0,05 – 50,0)mg/kg\nFtalan benzylu butylu (0,05 – 50,0) mg/kg\nFtalan diizobutylu (0,05 – 50,0) mg/kg\nFtalan dibutylu (0,05 – 50,0) mg/kg\nSuma ftalanów (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) EFO/PB/41/C:17.09.2025 Osady denne Zawartosc ftalanow\nZakres:\nFtalan dietylu (0,05 – 50,0) mg/kg\nFtalan di (2-etyloheksylu) (DEHP)\nZakres (0,05 – 50,0)mg/kg\nFtalan benzylu butylu (0,05 – 50,0) mg/kg\nFtalan diizobutylu (0,05 – 50,0) mg/kg\nFtalan dibutylu (0,05 – 50,0) mg/kg\nSuma ftalanow (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) EFO/PB/41/C:17.09.2025","categories":["water"],"row_index":279,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phthalate content","parameters_en":[{"name":"Diethyl phthalate","range":"(0,05 – 50,0) mg/kg"},{"name":"Phthalate di","range":"(2-etyloheksylu) (DEHP)"},{"name":"Range","range":"(0,05 – 50,0)mg/kg"},{"name":"Benzyl butyl phthalate","range":"(0,05 – 50,0) mg/kg"},{"name":"Diisobutyl phthalate","range":"(0,05 – 50,0) mg/kg"},{"name":"Dibutyl phthalate","range":"(0,05 – 50,0) mg/kg"},{"name":"Sum of phthalates (calculated)"}],"search_en":"Bottom sediments Phthalate content Gas chromatography with mass spectrometry detection (GC-MS) Diethyl phthalate Phthalate di Range Benzyl butyl phthalate Diisobutyl phthalate Dibutyl phthalate Sum of phthalates (calculated) EFO/PB/41/C:17.09.2025","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Bottom sediments","parameters_zh":[{"name":"邻苯二甲酸二乙酯","range":"(0,05 – 50,0) mg/kg"},{"name":"Ftalan di","range":"(2-etyloheksylu) (DEHP)"},{"name":"范围","range":"(0,05 – 50,0)mg/kg"},{"name":"Ftalan benzylu butylu","range":"(0,05 – 50,0) mg/kg"},{"name":"Ftalan diizobutylu","range":"(0,05 – 50,0) mg/kg"},{"name":"Ftalan dibutylu","range":"(0,05 – 50,0) mg/kg"},{"name":"邻苯二甲酸酯总量（由计算得出）"}],"search_zh":"底泥 邻苯二甲酸酯含量 气相色谱-质谱法（GC-MS） 邻苯二甲酸二乙酯 范围 邻苯二甲酸酯总量（由计算得出） EFO/PB/41/C:17.09.2025","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"底泥","methodology_zh":"邻苯二甲酸酯含量"},{"_id":"6a832b7f884ede9a1b2c55e0","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady denne","methodology":"Zawartość rtęci","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość rtęci","reference":"PN-EN ISO 12846:2012","norm_bases":["PN-EN ISO 12846:2012"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne Zawartość rtęci PN-EN ISO 12846:2012 Osady denne Zawartosc rteci PN-EN ISO 12846:2012","categories":["water"],"row_index":280,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","search_en":"Bottom sediments Mercury content PN-EN ISO 12846:2012","test_object_en":"Bottom sediments","methodology_zh":"汞含量","search_zh":"底泥 汞含量 PN-EN ISO 12846:2012","test_object_zh":"底泥"},{"_id":"6a832b7f884ede9a1b2c55e1","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady denne","methodology":"","parameters":[{"name":"Zakres","range":"(0,05 – 25,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zakres (0,05 – 25,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"+Ap1:2016-07","norm_bases":["+Ap1:2016-07"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne Zakres (0,05 – 25,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) +Ap1:2016-07 Osady denne Zakres (0,05 – 25,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) +Ap1:2016-07","categories":["water"],"row_index":281,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,05 – 25,0) mg/kg"}],"search_en":"Bottom sediments Cold vapour atomic absorption spectrometry (CVAAS) Range +Ap1:2016-07","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Bottom sediments","parameters_zh":[{"name":"范围","range":"(0,05 – 25,0) mg/kg"}],"search_zh":"底泥 冷蒸气原子吸收光谱法（CVAAS） 范围 +Ap1:2016-07","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"底泥"},{"_id":"6a832b7f884ede9a1b2c55e2","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady denne","methodology":"Sucha masa / zawartość wody","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa / zawartość wody\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02","norm_bases":["PN-EN 15934:2013-02"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne Sucha masa / zawartość wody\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15934:2013-02 Osady denne Sucha masa / zawartosc wody\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15934:2013-02","categories":["water"],"row_index":282,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter / water content","parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"search_en":"Bottom sediments Dry matter / water content Gravimetric method Range PN-EN 15934:2013-02","technique_en":"Gravimetric method","test_object_en":"Bottom sediments","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"底泥 干物质 / 水分含量 重量法 范围 PN-EN 15934:2013-02","technique_zh":"重量法","methodology_zh":"干物质 / 水分含量","test_object_zh":"底泥"},{"_id":"6a832b7f884ede9a1b2c55e3","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady denne","methodology":"Sucha masa / zawartość wody","parameters":[{"name":"Zakres","range":"(0,10 – 99,5) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Sucha masa / zawartość wody\nZakres (0,10 – 99,5) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN 15934:2013-02 Metoda A Dokumenty odniesienia","norm_bases":["PN-EN 15934:2013-02 Metoda A Dokumenty odniesienia"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne Sucha masa / zawartość wody\nZakres (0,10 – 99,5) %\nMetoda termograwimetryczna (TGA) PN-EN 15934:2013-02 Metoda A Dokumenty odniesienia Osady denne Sucha masa / zawartosc wody\nZakres (0,10 – 99,5) %\nMetoda termograwimetryczna (TGA) PN-EN 15934:2013-02 Metoda A Dokumenty odniesienia","categories":["water"],"row_index":283,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter / water content","parameters_en":[{"name":"Range","range":"(0,10 – 99,5) %"}],"search_en":"Bottom sediments Dry matter / water content Thermogravimetric method (TGA) Range PN-EN 15934:2013-02 Metoda A Dokumenty odniesienia","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Bottom sediments","parameters_zh":[{"name":"范围","range":"(0,10 – 99,5) %"}],"search_zh":"底泥 干物质 / 水分含量 热重法（TGA） 范围 PN-EN 15934:2013-02 Metoda A Dokumenty odniesienia","technique_zh":"热重法（TGA）","methodology_zh":"干物质 / 水分含量","test_object_zh":"底泥"},{"_id":"6a832b7f884ede9a1b2c55e4","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady denne, Gleba","methodology":"Zawartość alkilofenoli","parameters":[{"name":"Zakres","range":"4-Nonylofenol (0,010 – 10,0) mg/kg"},{"name":"Oktylofenol","range":"(0,010 – 10,0) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Zawartość alkilofenoli\nZakres:\nZakres 4-Nonylofenol (0,010 – 10,0) mg/kg\nOktylofenol (0,010 – 10,0) mg/kg\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"EFO/PB/24/A: 18.09.2023","norm_bases":["EFO/PB/24/A: 18.09.2023"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne, Gleba Zawartość alkilofenoli\nZakres:\nZakres 4-Nonylofenol (0,010 – 10,0) mg/kg\nOktylofenol (0,010 – 10,0) mg/kg\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) EFO/PB/24/A: 18.09.2023 Osady denne, Gleba Zawartosc alkilofenoli\nZakres:\nZakres 4-Nonylofenol (0,010 – 10,0) mg/kg\nOktylofenol (0,010 – 10,0) mg/kg\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) EFO/PB/24/A: 18.09.2023","categories":["water","environment"],"row_index":284,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Alkylphenol content","parameters_en":[{"name":"Range","range":"4-Nonylofenol (0,010 – 10,0) mg/kg"},{"name":"Octylphenol","range":"(0,010 – 10,0) mg/kg"}],"search_en":"Bottom sediments, Soil Alkylphenol content Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) Range Octylphenol EFO/PB/24/A: 18.09.2023","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","test_object_en":"Bottom sediments, Soil","parameters_zh":[{"name":"范围","range":"4-Nonylofenol (0,010 – 10,0) mg/kg"},{"name":"Oktylofenol","range":"(0,010 – 10,0) mg/kg"}],"search_zh":"底泥、土壤 气相色谱-串联质谱法（GC-MS-MS） 范围 EFO/PB/24/A: 18.09.2023","technique_zh":"气相色谱-串联质谱法（GC-MS-MS）","test_object_zh":"底泥、土壤"},{"_id":"6a832b7f884ede9a1b2c55e5","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady denne, Gleba","methodology":"Zawartość bromowanych difenyloeteryów","parameters":[{"name":"(Kongenery","range":"28,47,99,100,153,154)"},{"name":"Zakres","range":"(0,001 – 5,0) mg/kg"},{"name":"Suma (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Zawartość bromowanych difenyloeteryów\nZakres:\n(Kongenery 28,47,99,100,153,154)\nZakres (0,001 – 5,0) mg/kg\nSuma (z obliczeń)\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"PN-EN ISO 22032:2009","norm_bases":["PN-EN ISO 22032:2009"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne, Gleba Zawartość bromowanych difenyloeteryów\nZakres:\n(Kongenery 28,47,99,100,153,154)\nZakres (0,001 – 5,0) mg/kg\nSuma (z obliczeń)\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) PN-EN ISO 22032:2009 Osady denne, Gleba Zawartosc bromowanych difenyloeteryow\nZakres:\n(Kongenery 28,47,99,100,153,154)\nZakres (0,001 – 5,0) mg/kg\nSuma (z obliczen)\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) PN-EN ISO 22032:2009","categories":["water","environment"],"row_index":285,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Brominated diphenyl ether content","parameters_en":[{"name":"(Congeners","range":"28,47,99,100,153,154)"},{"name":"Range","range":"(0,001 – 5,0) mg/kg"},{"name":"Sum (calculated)"}],"search_en":"Bottom sediments, Soil Brominated diphenyl ether content Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) (Congeners Range Sum (calculated) PN-EN ISO 22032:2009","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","test_object_en":"Bottom sediments, Soil","parameters_zh":[{"name":"(Kongenery","range":"28,47,99,100,153,154)"},{"name":"范围","range":"(0,001 – 5,0) mg/kg"},{"name":"总量（由计算得出）"}],"search_zh":"底泥、土壤 气相色谱-串联质谱法（GC-MS-MS） 范围 总量（由计算得出） PN-EN ISO 22032:2009","technique_zh":"气相色谱-串联质谱法（GC-MS-MS）","test_object_zh":"底泥、土壤"},{"_id":"6a832b7f884ede9a1b2c55e6","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady denne, Gleba","methodology":"Zawartość chlorobenzenów","parameters":[{"name":"Monochlorobenzen","range":"(0,001 – 5,0) mg/kg"},{"name":"Zakres","range":"1,2-Dichlorobenzen (0,001 – 5,0) mg/kg"},{"name":"1,3- Dichlorobenzen","range":"(0,001 – 5,0) mg/kg"},{"name":"1,4- Dichlorobenzen","range":"(0,001 – 5,0) mg/kg"},{"name":"1,2,3-Trichlorobenzen","range":"(0,001 – 5,0) mg/kg"},{"name":"1,2,4-Trichlorobenzen","range":"(0,001 – 5,0) mg/kg"},{"name":"1,3,5-Trichlorobenzen","range":"(0,001 – 5,0) mg/kg"},{"name":"1,2,3,4-Tetrachlorobenzen","range":"(0,001 – 5,0) mg/kg"},{"name":"1,2,3,5-Tetrachlorobenzen","range":"(0,001 – 5,0) mg/kg"},{"name":"1,2,4,5-Tetrachlorobenzen","range":"(0,001 – 5,0) mg/kg"},{"name":"Pentachlorobenzen","range":"(0,0005 – 5,0) mg/kg"},{"name":"Heksachlorobenzen (HCB)","range":"(0,001 – 5,0) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Zawartość chlorobenzenów\nZakres:\nMonochlorobenzen (0,001 – 5,0) mg/kg\nZakres 1,2-Dichlorobenzen (0,001 – 5,0) mg/kg\n1,3- Dichlorobenzen (0,001 – 5,0) mg/kg\n1,4- Dichlorobenzen (0,001 – 5,0) mg/kg\n1,2,3-Trichlorobenzen (0,001 – 5,0) mg/kg\n1,2,4-Trichlorobenzen (0,001 – 5,0) mg/kg\n1,3,5-Trichlorobenzen (0,001 – 5,0) mg/kg\n1,2,3,4-Tetrachlorobenzen (0,001 – 5,0) mg/kg\n1,2,3,5-Tetrachlorobenzen (0,001 – 5,0) mg/kg\n1,2,4,5-Tetrachlorobenzen (0,001 – 5,0) mg/kg\nPentachlorobenzen (0,0005 – 5,0) mg/kg\nHeksachlorobenzen (HCB) (0,001 – 5,0) mg/kg\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"PN-EN ISO 22155:2016 Dokumenty odniesienia","norm_bases":["PN-EN ISO 22155:2016 Dokumenty odniesienia"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne, Gleba Zawartość chlorobenzenów\nZakres:\nMonochlorobenzen (0,001 – 5,0) mg/kg\nZakres 1,2-Dichlorobenzen (0,001 – 5,0) mg/kg\n1,3- Dichlorobenzen (0,001 – 5,0) mg/kg\n1,4- Dichlorobenzen (0,001 – 5,0) mg/kg\n1,2,3-Trichlorobenzen (0,001 – 5,0) mg/kg\n1,2,4-Trichlorobenzen (0,001 – 5,0) mg/kg\n1,3,5-Trichlorobenzen (0,001 – 5,0) mg/kg\n1,2,3,4-Tetrachlorobenzen (0,001 – 5,0) mg/kg\n1,2,3,5-Tetrachlorobenzen (0,001 – 5,0) mg/kg\n1,2,4,5-Tetrachlorobenzen (0,001 – 5,0) mg/kg\nPentachlorobenzen (0,0005 – 5,0) mg/kg\nHeksachlorobenzen (HCB) (0,001 – 5,0) mg/kg\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) PN-EN ISO 22155:2016 Dokumenty odniesienia Osady denne, Gleba Zawartosc chlorobenzenow\nZakres:\nMonochlorobenzen (0,001 – 5,0) mg/kg\nZakres 1,2-Dichlorobenzen (0,001 – 5,0) mg/kg\n1,3- Dichlorobenzen (0,001 – 5,0) mg/kg\n1,4- Dichlorobenzen (0,001 – 5,0) mg/kg\n1,2,3-Trichlorobenzen (0,001 – 5,0) mg/kg\n1,2,4-Trichlorobenzen (0,001 – 5,0) mg/kg\n1,3,5-Trichlorobenzen (0,001 – 5,0) mg/kg\n1,2,3,4-Tetrachlorobenzen (0,001 – 5,0) mg/kg\n1,2,3,5-Tetrachlorobenzen (0,001 – 5,0) mg/kg\n1,2,4,5-Tetrachlorobenzen (0,001 – 5,0) mg/kg\nPentachlorobenzen (0,0005 – 5,0) mg/kg\nHeksachlorobenzen (HCB) (0,001 – 5,0) mg/kg\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) PN-EN ISO 22155:2016 Dokumenty odniesienia","categories":["water","environment"],"row_index":286,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorobenzene content","parameters_en":[{"name":"Monochlorobenzene","range":"(0,001 – 5,0) mg/kg"},{"name":"Range","range":"1,2-Dichlorobenzen (0,001 – 5,0) mg/kg"},{"name":"1,3- Dichlorobenzene","range":"(0,001 – 5,0) mg/kg"},{"name":"1,4- Dichlorobenzene","range":"(0,001 – 5,0) mg/kg"},{"name":"1,2,3-Trichlorobenzene","range":"(0,001 – 5,0) mg/kg"},{"name":"1,2,4-Trichlorobenzene","range":"(0,001 – 5,0) mg/kg"},{"name":"1,3,5-Trichlorobenzene","range":"(0,001 – 5,0) mg/kg"},{"name":"1,2,3,4-Tetrachlorobenzene","range":"(0,001 – 5,0) mg/kg"},{"name":"1,2,3,5-Tetrachlorobenzene","range":"(0,001 – 5,0) mg/kg"},{"name":"1,2,4,5-Tetrachlorobenzene","range":"(0,001 – 5,0) mg/kg"},{"name":"Pentachlorobenzene","range":"(0,0005 – 5,0) mg/kg"},{"name":"Hexachlorobenzene (HCB)","range":"(0,001 – 5,0) mg/kg"}],"search_en":"Bottom sediments, Soil Chlorobenzene content Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) Monochlorobenzene Range 1,3- Dichlorobenzene 1,4- Dichlorobenzene 1,2,3-Trichlorobenzene 1,2,4-Trichlorobenzene 1,3,5-Trichlorobenzene 1,2,3,4-Tetrachlorobenzene 1,2,3,5-Tetrachlorobenzene 1,2,4,5-Tetrachlorobenzene Pentachlorobenzene Hexachlorobenzene (HCB) PN-EN ISO 22155:2016 Dokumenty odniesienia","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","test_object_en":"Bottom sediments, Soil","parameters_zh":[{"name":"Monochlorobenzen","range":"(0,001 – 5,0) mg/kg"},{"name":"范围","range":"1,2-Dichlorobenzen (0,001 – 5,0) mg/kg"},{"name":"1,3- Dichlorobenzen","range":"(0,001 – 5,0) mg/kg"},{"name":"1,4- Dichlorobenzen","range":"(0,001 – 5,0) mg/kg"},{"name":"1,2,3-Trichlorobenzen","range":"(0,001 – 5,0) mg/kg"},{"name":"1,2,4-三氯苯","range":"(0,001 – 5,0) mg/kg"},{"name":"1,3,5-三氯苯","range":"(0,001 – 5,0) mg/kg"},{"name":"1,2,3,4-Tetrachlorobenzen","range":"(0,001 – 5,0) mg/kg"},{"name":"1,2,3,5-Tetrachlorobenzen","range":"(0,001 – 5,0) mg/kg"},{"name":"1,2,4,5-Tetrachlorobenzen","range":"(0,001 – 5,0) mg/kg"},{"name":"五氯苯","range":"(0,0005 – 5,0) mg/kg"},{"name":"六氯苯（HCB）","range":"(0,001 – 5,0) mg/kg"}],"search_zh":"底泥、土壤 氯苯类含量 气相色谱-串联质谱法（GC-MS-MS） 范围 1,2,4-三氯苯 1,3,5-三氯苯 五氯苯 六氯苯（HCB） PN-EN ISO 22155:2016 Dokumenty odniesienia","technique_zh":"气相色谱-串联质谱法（GC-MS-MS）","methodology_zh":"氯苯类含量","test_object_zh":"底泥、土壤"},{"_id":"6a832b7f884ede9a1b2c55e7","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady denne, Gleba, Grunty","methodology":"Zawartość chlorofenoli","parameters":[{"name":"Zakres","range":"2-chlorofenol (0,010 – 5,0) mg/kg"},{"name":"3-chlorofenol","range":"(0,010 – 5,0) mg/kg"},{"name":"4-chlorofenol","range":"(0,010 – 5,0) mg/kg"},{"name":"2,3-dichlorofenol","range":"(0,010 – 5,0) mg/kg"},{"name":"2,4-dichlorofenol i 2,5-dichlorofenol","range":"(0,010 – 10,0) mg/kg (suma)"},{"name":"2,6-dichlorofenol","range":"(0,010 – 5,0) mg/kg"},{"name":"3,4-dichlorofenol","range":"(0,010 – 5,0) mg/kg"},{"name":"3,5-dichlorofenol","range":"(0,010 – 5,0) mg/kg"},{"name":"2,3,4-trichlorofenol","range":"(0,010 – 5,0) mg/kg"},{"name":"2,3,5-trichlorofenol","range":"(0,010 – 5,0) mg/kg"},{"name":"2,3,6-trichlorofenol","range":"(0,010 – 5,0) mg/kg"},{"name":"2,4,5-trichlorofenol","range":"(0,010 – 5,0) mg/kg"},{"name":"2,4,6-trichlorofenol","range":"(0,010 – 5,0) mg/kg"},{"name":"3,4,5-trichlorofenol","range":"(0,010 – 5,0) mg/kg"},{"name":"2,3,4,5-tetrachlorofenol","range":"(0,010 – 5,0) mg/kg"},{"name":"2,3,4,6-tetrachlorofenol","range":"(0,010 – 5,0) mg/kg"},{"name":"2,3,5,6-tetrachlorofenol","range":"(0,010 – 5,0) mg/kg"},{"name":"pentachlorofenol (PCP)","range":"(0,010 – 5,0) mg/kg"},{"name":"Suma: chlorofenoli monochlorofenoli dichlorofenoli trichlorofenoli tetrachlorofenoli (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Zawartość chlorofenoli\nZakres:\nZakres 2-chlorofenol (0,010 – 5,0) mg/kg\n3-chlorofenol (0,010 – 5,0) mg/kg\n4-chlorofenol (0,010 – 5,0) mg/kg\n2,3-dichlorofenol (0,010 – 5,0) mg/kg\n2,4-dichlorofenol i 2,5-dichlorofenol (0,010 – 10,0) mg/kg (suma)\n2,6-dichlorofenol (0,010 – 5,0) mg/kg\n3,4-dichlorofenol (0,010 – 5,0) mg/kg\n3,5-dichlorofenol (0,010 – 5,0) mg/kg\n2,3,4-trichlorofenol (0,010 – 5,0) mg/kg\n2,3,5-trichlorofenol (0,010 – 5,0) mg/kg\n2,3,6-trichlorofenol (0,010 – 5,0) mg/kg\n2,4,5-trichlorofenol (0,010 – 5,0) mg/kg\n2,4,6-trichlorofenol (0,010 – 5,0) mg/kg\n3,4,5-trichlorofenol (0,010 – 5,0) mg/kg\n2,3,4,5-tetrachlorofenol (0,010 – 5,0) mg/kg\n2,3,4,6-tetrachlorofenol (0,010 – 5,0) mg/kg\n2,3,5,6-tetrachlorofenol (0,010 – 5,0) mg/kg\npentachlorofenol (PCP) (0,010 – 5,0) mg/kg\nSuma: chlorofenoli monochlorofenoli dichlorofenoli trichlorofenoli tetrachlorofenoli (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS-MS)","reference":"PN-ISO 14154:2008 EFO/I/45/2:17.09.2025 r.","norm_bases":["PN-ISO 14154:2008 EFO/I/45/2:17.09.2025 r."],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne, Gleba, Grunty Zawartość chlorofenoli\nZakres:\nZakres 2-chlorofenol (0,010 – 5,0) mg/kg\n3-chlorofenol (0,010 – 5,0) mg/kg\n4-chlorofenol (0,010 – 5,0) mg/kg\n2,3-dichlorofenol (0,010 – 5,0) mg/kg\n2,4-dichlorofenol i 2,5-dichlorofenol (0,010 – 10,0) mg/kg (suma)\n2,6-dichlorofenol (0,010 – 5,0) mg/kg\n3,4-dichlorofenol (0,010 – 5,0) mg/kg\n3,5-dichlorofenol (0,010 – 5,0) mg/kg\n2,3,4-trichlorofenol (0,010 – 5,0) mg/kg\n2,3,5-trichlorofenol (0,010 – 5,0) mg/kg\n2,3,6-trichlorofenol (0,010 – 5,0) mg/kg\n2,4,5-trichlorofenol (0,010 – 5,0) mg/kg\n2,4,6-trichlorofenol (0,010 – 5,0) mg/kg\n3,4,5-trichlorofenol (0,010 – 5,0) mg/kg\n2,3,4,5-tetrachlorofenol (0,010 – 5,0) mg/kg\n2,3,4,6-tetrachlorofenol (0,010 – 5,0) mg/kg\n2,3,5,6-tetrachlorofenol (0,010 – 5,0) mg/kg\npentachlorofenol (PCP) (0,010 – 5,0) mg/kg\nSuma: chlorofenoli monochlorofenoli dichlorofenoli trichlorofenoli tetrachlorofenoli (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS-MS) PN-ISO 14154:2008 EFO/I/45/2:17.09.2025 r. Osady denne, Gleba, Grunty Zawartosc chlorofenoli\nZakres:\nZakres 2-chlorofenol (0,010 – 5,0) mg/kg\n3-chlorofenol (0,010 – 5,0) mg/kg\n4-chlorofenol (0,010 – 5,0) mg/kg\n2,3-dichlorofenol (0,010 – 5,0) mg/kg\n2,4-dichlorofenol i 2,5-dichlorofenol (0,010 – 10,0) mg/kg (suma)\n2,6-dichlorofenol (0,010 – 5,0) mg/kg\n3,4-dichlorofenol (0,010 – 5,0) mg/kg\n3,5-dichlorofenol (0,010 – 5,0) mg/kg\n2,3,4-trichlorofenol (0,010 – 5,0) mg/kg\n2,3,5-trichlorofenol (0,010 – 5,0) mg/kg\n2,3,6-trichlorofenol (0,010 – 5,0) mg/kg\n2,4,5-trichlorofenol (0,010 – 5,0) mg/kg\n2,4,6-trichlorofenol (0,010 – 5,0) mg/kg\n3,4,5-trichlorofenol (0,010 – 5,0) mg/kg\n2,3,4,5-tetrachlorofenol (0,010 – 5,0) mg/kg\n2,3,4,6-tetrachlorofenol (0,010 – 5,0) mg/kg\n2,3,5,6-tetrachlorofenol (0,010 – 5,0) mg/kg\npentachlorofenol (PCP) (0,010 – 5,0) mg/kg\nSuma: chlorofenoli monochlorofenoli dichlorofenoli trichlorofenoli tetrachlorofenoli (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS-MS) PN-ISO 14154:2008 EFO/I/45/2:17.09.2025 r.","categories":["water","environment"],"row_index":287,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorophenol content","parameters_en":[{"name":"Range","range":"2-chlorofenol (0,010 – 5,0) mg/kg"},{"name":"3-chlorophenol","range":"(0,010 – 5,0) mg/kg"},{"name":"4-chlorophenol","range":"(0,010 – 5,0) mg/kg"},{"name":"2,3-dichlorophenol","range":"(0,010 – 5,0) mg/kg"},{"name":"2,4-dichlorophenol and 2,5-dichlorophenol","range":"(0,010 – 10,0) mg/kg (suma)"},{"name":"2,6-dichlorophenol","range":"(0,010 – 5,0) mg/kg"},{"name":"3,4-dichlorophenol","range":"(0,010 – 5,0) mg/kg"},{"name":"3,5-dichlorophenol","range":"(0,010 – 5,0) mg/kg"},{"name":"2,3,4-trichlorophenol","range":"(0,010 – 5,0) mg/kg"},{"name":"2,3,5-trichlorophenol","range":"(0,010 – 5,0) mg/kg"},{"name":"2,3,6-trichlorophenol","range":"(0,010 – 5,0) mg/kg"},{"name":"2,4,5-trichlorophenol","range":"(0,010 – 5,0) mg/kg"},{"name":"2,4,6-trichlorophenol","range":"(0,010 – 5,0) mg/kg"},{"name":"3,4,5-trichlorophenol","range":"(0,010 – 5,0) mg/kg"},{"name":"2,3,4,5-tetrachlorophenol","range":"(0,010 – 5,0) mg/kg"},{"name":"2,3,4,6-tetrachlorophenol","range":"(0,010 – 5,0) mg/kg"},{"name":"2,3,5,6-tetrachlorophenol","range":"(0,010 – 5,0) mg/kg"},{"name":"pentachlorophenol (PCP)","range":"(0,010 – 5,0) mg/kg"},{"name":"Suma: chlorofenoli monochlorofenoli dichlorofenoli trichlorofenoli tetrachlorofenoli (z obliczeń)"}],"search_en":"Bottom sediments, Soil, Ground Chlorophenol content Gas chromatography with mass spectrometry detection (GC-MS-MS) Range 3-chlorophenol 4-chlorophenol 2,3-dichlorophenol 2,4-dichlorophenol and 2,5-dichlorophenol 2,6-dichlorophenol 3,4-dichlorophenol 3,5-dichlorophenol 2,3,4-trichlorophenol 2,3,5-trichlorophenol 2,3,6-trichlorophenol 2,4,5-trichlorophenol 2,4,6-trichlorophenol 3,4,5-trichlorophenol 2,3,4,5-tetrachlorophenol 2,3,4,6-tetrachlorophenol 2,3,5,6-tetrachlorophenol pentachlorophenol (PCP) PN-ISO 14154:2008 EFO/I/45/2:17.09.2025 r.","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS-MS)","test_object_en":"Bottom sediments, Soil, Ground","parameters_zh":[{"name":"范围","range":"2-chlorofenol (0,010 – 5,0) mg/kg"},{"name":"3-氯苯酚","range":"(0,010 – 5,0) mg/kg"},{"name":"4-氯苯酚","range":"(0,010 – 5,0) mg/kg"},{"name":"2,3-二氯苯酚","range":"(0,010 – 5,0) mg/kg"},{"name":"2,4-dichlorofenol i 2,5-dichlorofenol","range":"(0,010 – 10,0) mg/kg (suma)"},{"name":"2,6-二氯苯酚","range":"(0,010 – 5,0) mg/kg"},{"name":"3,4-二氯苯酚","range":"(0,010 – 5,0) mg/kg"},{"name":"3,5-二氯苯酚","range":"(0,010 – 5,0) mg/kg"},{"name":"2,3,4-三氯苯酚","range":"(0,010 – 5,0) mg/kg"},{"name":"2,3,5-三氯苯酚","range":"(0,010 – 5,0) mg/kg"},{"name":"2,3,6-三氯苯酚","range":"(0,010 – 5,0) mg/kg"},{"name":"2,4,5-三氯苯酚","range":"(0,010 – 5,0) mg/kg"},{"name":"2,4,6-三氯苯酚","range":"(0,010 – 5,0) mg/kg"},{"name":"3,4,5-三氯苯酚","range":"(0,010 – 5,0) mg/kg"},{"name":"2,3,4,5-四氯苯酚","range":"(0,010 – 5,0) mg/kg"},{"name":"2,3,4,6-四氯苯酚","range":"(0,010 – 5,0) mg/kg"},{"name":"2,3,5,6-tetrachlorofenol","range":"(0,010 – 5,0) mg/kg"},{"name":"五氯苯酚（PCP）","range":"(0,010 – 5,0) mg/kg"},{"name":"Suma: chlorofenoli monochlorofenoli dichlorofenoli trichlorofenoli tetrachlorofenoli (z obliczeń)"}],"search_zh":"氯酚含量 范围 3-氯苯酚 4-氯苯酚 2,3-二氯苯酚 2,6-二氯苯酚 3,4-二氯苯酚 3,5-二氯苯酚 2,3,4-三氯苯酚 2,3,5-三氯苯酚 2,3,6-三氯苯酚 2,4,5-三氯苯酚 2,4,6-三氯苯酚 3,4,5-三氯苯酚 2,3,4,5-四氯苯酚 2,3,4,6-四氯苯酚 五氯苯酚（PCP） PN-ISO 14154:2008 EFO/I/45/2:17.09.2025 r.","methodology_zh":"氯酚含量"},{"_id":"6a832b7f884ede9a1b2c55e8","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady denne, Gleba, Grunty","methodology":"Zawartość pestycydów","parameters":[{"name":"Atrazyna","range":"(0,003 – 3,0) mg/kg"},{"name":"Karbaryl","range":"(0,003 – 3,0) mg/kg"},{"name":"Karbofuran","range":"(0,003 – 3,0) mg/kg"},{"name":"Maneb","range":"(0,003 – 3,0) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość pestycydów\nZakres:\nAtrazyna (0,003 – 3,0) mg/kg\nKarbaryl (0,003 – 3,0) mg/kg\nKarbofuran (0,003 – 3,0) mg/kg\nManeb (0,003 – 3,0) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"PN-ISO 11264:2010 Dokumenty odniesienia","norm_bases":["PN-ISO 11264:2010 Dokumenty odniesienia"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne, Gleba, Grunty Zawartość pestycydów\nZakres:\nAtrazyna (0,003 – 3,0) mg/kg\nKarbaryl (0,003 – 3,0) mg/kg\nKarbofuran (0,003 – 3,0) mg/kg\nManeb (0,003 – 3,0) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) PN-ISO 11264:2010 Dokumenty odniesienia Osady denne, Gleba, Grunty Zawartosc pestycydow\nZakres:\nAtrazyna (0,003 – 3,0) mg/kg\nKarbaryl (0,003 – 3,0) mg/kg\nKarbofuran (0,003 – 3,0) mg/kg\nManeb (0,003 – 3,0) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) PN-ISO 11264:2010 Dokumenty odniesienia","categories":["water","environment"],"row_index":288,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pesticide content","parameters_en":[{"name":"Atrazine","range":"(0,003 – 3,0) mg/kg"},{"name":"Carbaryl","range":"(0,003 – 3,0) mg/kg"},{"name":"Carbofuran","range":"(0,003 – 3,0) mg/kg"},{"name":"Maneb","range":"(0,003 – 3,0) mg/kg"}],"search_en":"Bottom sediments, Soil, Ground Pesticide content High-performance liquid chromatography with diode array detection (HPLC-DAD) Atrazine Carbaryl Carbofuran Maneb PN-ISO 11264:2010 Dokumenty odniesienia","technique_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD)","test_object_en":"Bottom sediments, Soil, Ground","search_zh":"农药含量 高效液相色谱-二极管阵列检测法（HPLC-DAD） 莠去津 PN-ISO 11264:2010 Dokumenty odniesienia","technique_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD）","methodology_zh":"农药含量","parameters_zh":[{"name":"莠去津","range":"(0,003 – 3,0) mg/kg"},{"name":"Karbaryl","range":"(0,003 – 3,0) mg/kg"},{"name":"Karbofuran","range":"(0,003 – 3,0) mg/kg"},{"name":"Maneb","range":"(0,003 – 3,0) mg/kg"}]},{"_id":"6a832b7f884ede9a1b2c55e9","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady denne, Gleba","methodology":"Zawartość pestycydów","parameters":[{"name":"Dikofol","range":"(0,0005 – 5,0) mg/kg"},{"name":"Chinoksyfen","range":"(0,0005 – 5,0) mg/kg"},{"name":"Trifluralina","range":"(0,001 – 5,0) mg/kg"},{"name":"Chlorfenwinfos","range":"(0,001 – 5,0) mg/kg"},{"name":"Aklonifen","range":"(0,0005 – 5,0) mg/kg"},{"name":"Bifenoks","range":"(0,0005 – 5,0) mg/kg"},{"name":"Cybutryna (Irgarol)"},{"name":"Zakres","range":"(0,0001 – 5,0) mg/kg"},{"name":"Cypermetryna","range":"(0,0005 – 5,0) mg/kg"},{"name":"Dichlorfos","range":"(0,001 – 5,0) mg/kg"},{"name":"Terbutryna","range":"(0,001 – 5,0) mg/kg"},{"name":"Heptachlor","range":"(0,001 – 5,0) mg/kg"},{"name":"Epoksyd heptachloru izomer A","range":"(0,001 – 5,0) mg/kg"},{"name":"Epoksyd heptahloru izomer B","range":"(0,001 – 5,0) mg/kg"},{"name":"Chlorpiryfos","range":"(0,001 – 5,0) mg/kg"},{"name":"Chlordekon","range":"(0,0005 – 5,0) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Zawartość pestycydów\nZakres:\nDikofol (0,0005 – 5,0) mg/kg\nChinoksyfen (0,0005 – 5,0) mg/kg\nTrifluralina (0,001 – 5,0) mg/kg\nChlorfenwinfos (0,001 – 5,0) mg/kg\nAklonifen (0,0005 – 5,0) mg/kg\nBifenoks (0,0005 – 5,0) mg/kg\nCybutryna (Irgarol)\nZakres (0,0001 – 5,0) mg/kg\nCypermetryna (0,0005 – 5,0) mg/kg\nDichlorfos (0,001 – 5,0) mg/kg\nTerbutryna (0,001 – 5,0) mg/kg\nHeptachlor (0,001 – 5,0) mg/kg\nEpoksyd heptachloru izomer A (0,001 – 5,0) mg/kg\nEpoksyd heptahloru izomer B (0,001 – 5,0) mg/kg\nChlorpiryfos (0,001 – 5,0) mg/kg\nChlordekon (0,0005 – 5,0) mg/kg\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"EFO/PB/24/A z dnia 18.09.2023 r. | na podstawie normy: | PN-ISO 10382:2007 Dokumenty odniesienia","norm_bases":["EFO/PB/24/A z dnia 18.09.2023 r.","na podstawie normy:","PN-ISO 10382:2007 Dokumenty odniesienia"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne, Gleba Zawartość pestycydów\nZakres:\nDikofol (0,0005 – 5,0) mg/kg\nChinoksyfen (0,0005 – 5,0) mg/kg\nTrifluralina (0,001 – 5,0) mg/kg\nChlorfenwinfos (0,001 – 5,0) mg/kg\nAklonifen (0,0005 – 5,0) mg/kg\nBifenoks (0,0005 – 5,0) mg/kg\nCybutryna (Irgarol)\nZakres (0,0001 – 5,0) mg/kg\nCypermetryna (0,0005 – 5,0) mg/kg\nDichlorfos (0,001 – 5,0) mg/kg\nTerbutryna (0,001 – 5,0) mg/kg\nHeptachlor (0,001 – 5,0) mg/kg\nEpoksyd heptachloru izomer A (0,001 – 5,0) mg/kg\nEpoksyd heptahloru izomer B (0,001 – 5,0) mg/kg\nChlorpiryfos (0,001 – 5,0) mg/kg\nChlordekon (0,0005 – 5,0) mg/kg\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) EFO/PB/24/A z dnia 18.09.2023 r. | na podstawie normy: | PN-ISO 10382:2007 Dokumenty odniesienia Osady denne, Gleba Zawartosc pestycydow\nZakres:\nDikofol (0,0005 – 5,0) mg/kg\nChinoksyfen (0,0005 – 5,0) mg/kg\nTrifluralina (0,001 – 5,0) mg/kg\nChlorfenwinfos (0,001 – 5,0) mg/kg\nAklonifen (0,0005 – 5,0) mg/kg\nBifenoks (0,0005 – 5,0) mg/kg\nCybutryna (Irgarol)\nZakres (0,0001 – 5,0) mg/kg\nCypermetryna (0,0005 – 5,0) mg/kg\nDichlorfos (0,001 – 5,0) mg/kg\nTerbutryna (0,001 – 5,0) mg/kg\nHeptachlor (0,001 – 5,0) mg/kg\nEpoksyd heptachloru izomer A (0,001 – 5,0) mg/kg\nEpoksyd heptahloru izomer B (0,001 – 5,0) mg/kg\nChlorpiryfos (0,001 – 5,0) mg/kg\nChlordekon (0,0005 – 5,0) mg/kg\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) EFO/PB/24/A z dnia 18.09.2023 r. | na podstawie normy: | PN-ISO 10382:2007 Dokumenty odniesienia","categories":["water","environment"],"row_index":289,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pesticide content","parameters_en":[{"name":"Dicofol","range":"(0,0005 – 5,0) mg/kg"},{"name":"Quinoxyfen","range":"(0,0005 – 5,0) mg/kg"},{"name":"Trifluralin","range":"(0,001 – 5,0) mg/kg"},{"name":"Chlorfenvinphos","range":"(0,001 – 5,0) mg/kg"},{"name":"Aclonifen","range":"(0,0005 – 5,0) mg/kg"},{"name":"Bifenox","range":"(0,0005 – 5,0) mg/kg"},{"name":"Cybutryne (Irgarol)"},{"name":"Range","range":"(0,0001 – 5,0) mg/kg"},{"name":"Cypermethrin","range":"(0,0005 – 5,0) mg/kg"},{"name":"Dichlorvos","range":"(0,001 – 5,0) mg/kg"},{"name":"Terbutryn","range":"(0,001 – 5,0) mg/kg"},{"name":"Heptachlor","range":"(0,001 – 5,0) mg/kg"},{"name":"Heptachlor epoxide isomer A","range":"(0,001 – 5,0) mg/kg"},{"name":"Heptachlor epoxide isomer B","range":"(0,001 – 5,0) mg/kg"},{"name":"Chlorpyrifos","range":"(0,001 – 5,0) mg/kg"},{"name":"Chlordecone","range":"(0,0005 – 5,0) mg/kg"}],"search_en":"Bottom sediments, Soil Pesticide content Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) Dicofol Quinoxyfen Trifluralin Chlorfenvinphos Aclonifen Bifenox Cybutryne (Irgarol) Range Cypermethrin Dichlorvos Terbutryn Heptachlor Heptachlor epoxide isomer A Heptachlor epoxide isomer B Chlorpyrifos Chlordecone EFO/PB/24/A z dnia 18.09.2023 r. | na podstawie normy: | PN-ISO 10382:2007 Dokumenty odniesienia","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","test_object_en":"Bottom sediments, Soil","parameters_zh":[{"name":"Dikofol","range":"(0,0005 – 5,0) mg/kg"},{"name":"Chinoksyfen","range":"(0,0005 – 5,0) mg/kg"},{"name":"Trifluralina","range":"(0,001 – 5,0) mg/kg"},{"name":"Chlorfenwinfos","range":"(0,001 – 5,0) mg/kg"},{"name":"Aklonifen","range":"(0,0005 – 5,0) mg/kg"},{"name":"Bifenoks","range":"(0,0005 – 5,0) mg/kg"},{"name":"Cybutryna (Irgarol)"},{"name":"范围","range":"(0,0001 – 5,0) mg/kg"},{"name":"Cypermetryna","range":"(0,0005 – 5,0) mg/kg"},{"name":"Dichlorfos","range":"(0,001 – 5,0) mg/kg"},{"name":"Terbutryna","range":"(0,001 – 5,0) mg/kg"},{"name":"七氯","range":"(0,001 – 5,0) mg/kg"},{"name":"Epoksyd heptachloru izomer A","range":"(0,001 – 5,0) mg/kg"},{"name":"Epoksyd heptahloru izomer B","range":"(0,001 – 5,0) mg/kg"},{"name":"Chlorpiryfos","range":"(0,001 – 5,0) mg/kg"},{"name":"Chlordekon","range":"(0,0005 – 5,0) mg/kg"}],"search_zh":"底泥、土壤 农药含量 气相色谱-串联质谱法（GC-MS-MS） 范围 七氯 EFO/PB/24/A z dnia 18.09.2023 r. | na podstawie normy: | PN-ISO 10382:2007 Dokumenty odniesienia","technique_zh":"气相色谱-串联质谱法（GC-MS-MS）","methodology_zh":"农药含量","test_object_zh":"底泥、土壤"},{"_id":"6a832b7f884ede9a1b2c55ea","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady denne, Gleba","methodology":"Zawartość pestycydów","parameters":[{"name":"Alachlor","range":"(0,001 – 5,0) mg/kg"},{"name":"Aldryna","range":"(0,001 – 5,0) mg/kg"},{"name":"Dieldryna","range":"(0,0005 – 5,0) mg/kg"},{"name":"Endryna","range":"(0,001 – 5,0) mg/kg"},{"name":"Izodryna","range":"(0,001 – 5,0) mg/kg"},{"name":"o,p-dichlorodifenylotrichloroetan (o,p’- DDT)","range":"(0,001 – 5,0) mg/kg"},{"name":"p,p’dichlorodifenylotrichloroetan (p,p’- DDT)","range":"(0,001 – 5,0) mg/kg"},{"name":"α-heksachlorocykloheksan (α-HCH)"},{"name":"Zakres","range":"(0,0001 – 5,0) mg/kg"},{"name":"β-heksachlorocykloheksan (β-HCH)","range":"(0,0001 – 5,0) mg/kg"},{"name":"γ-heksachlorocykloheksan (γ-HCH)","range":"(0,0001 – 5,0) mg/kg"},{"name":"δ-heksachlorocykloheksan (δ-HCH)","range":"(0,0001 – 5,0) mg/kg"},{"name":"Heksachlorobutadien (HCBD)","range":"(0,001 – 5,0) mg/kg"},{"name":"o,p‘- dichlorodifenylodichloroetan (o,p‘- DDD)","range":"(0,001 – 5,0) mg/kg"},{"name":"p,p‘- dichlorodifenylodichloroetan (p,p‘- DDD)","range":"(0,001 – 5,0) mg/kg"},{"name":"o,p‘-dichlorodifenylodichloroetylen (o,p‘-DDE)","range":"(0,001 – 5,0) mg/kg"},{"name":"p,p‘-dichlorodifenylodichloroetylen (p,p‘-DDE)","range":"(0,001 – 5,0) mg/kg"},{"name":"Metoksychlor (DMDT)","range":"(0,001 – 5,0) mg/kg"},{"name":"Endosulfan I","range":"(0,001 – 5,0) mg/kg"},{"name":"Endosulfan II","range":"(0,001 – 5,0) mg/kg"},{"name":"Aldehyd endryny","range":"(0,001 – 5,0) mg/kg"},{"name":"Chlordan","range":"(0,001 – 5,0) mg/kg"},{"name":"Siarczan endosulfanu","range":"(0,001 – 5,0) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Zawartość pestycydów\nZakres:\nAlachlor (0,001 – 5,0) mg/kg\nAldryna (0,001 – 5,0) mg/kg\nDieldryna (0,0005 – 5,0) mg/kg\nEndryna (0,001 – 5,0) mg/kg\nIzodryna (0,001 – 5,0) mg/kg\no,p-dichlorodifenylotrichloroetan (o,p’- DDT) (0,001 – 5,0) mg/kg\np,p’dichlorodifenylotrichloroetan (p,p’- DDT) (0,001 – 5,0) mg/kg\nα-heksachlorocykloheksan (α-HCH)\nZakres (0,0001 – 5,0) mg/kg\nβ-heksachlorocykloheksan (β-HCH) (0,0001 – 5,0) mg/kg\nγ-heksachlorocykloheksan (γ-HCH) (0,0001 – 5,0) mg/kg\nδ-heksachlorocykloheksan (δ-HCH) (0,0001 – 5,0) mg/kg\nHeksachlorobutadien (HCBD) (0,001 – 5,0) mg/kg\no,p‘- dichlorodifenylodichloroetan (o,p‘- DDD) (0,001 – 5,0) mg/kg\np,p‘- dichlorodifenylodichloroetan (p,p‘- DDD) (0,001 – 5,0) mg/kg\no,p‘-dichlorodifenylodichloroetylen (o,p‘-DDE) (0,001 – 5,0) mg/kg\np,p‘-dichlorodifenylodichloroetylen (p,p‘-DDE) (0,001 – 5,0) mg/kg\nMetoksychlor (DMDT) (0,001 – 5,0) mg/kg\nEndosulfan I (0,001 – 5,0) mg/kg\nEndosulfan II (0,001 – 5,0) mg/kg\nAldehyd endryny (0,001 – 5,0) mg/kg\nChlordan (0,001 – 5,0) mg/kg\nSiarczan endosulfanu (0,001 – 5,0) mg/kg\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"EFO/PB/24/A z dnia 18.09.2023 r. | na podstawie normy: | PN-ISO 10382:2007","norm_bases":["EFO/PB/24/A z dnia 18.09.2023 r.","na podstawie normy:","PN-ISO 10382:2007"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne, Gleba Zawartość pestycydów\nZakres:\nAlachlor (0,001 – 5,0) mg/kg\nAldryna (0,001 – 5,0) mg/kg\nDieldryna (0,0005 – 5,0) mg/kg\nEndryna (0,001 – 5,0) mg/kg\nIzodryna (0,001 – 5,0) mg/kg\no,p-dichlorodifenylotrichloroetan (o,p’- DDT) (0,001 – 5,0) mg/kg\np,p’dichlorodifenylotrichloroetan (p,p’- DDT) (0,001 – 5,0) mg/kg\nα-heksachlorocykloheksan (α-HCH)\nZakres (0,0001 – 5,0) mg/kg\nβ-heksachlorocykloheksan (β-HCH) (0,0001 – 5,0) mg/kg\nγ-heksachlorocykloheksan (γ-HCH) (0,0001 – 5,0) mg/kg\nδ-heksachlorocykloheksan (δ-HCH) (0,0001 – 5,0) mg/kg\nHeksachlorobutadien (HCBD) (0,001 – 5,0) mg/kg\no,p‘- dichlorodifenylodichloroetan (o,p‘- DDD) (0,001 – 5,0) mg/kg\np,p‘- dichlorodifenylodichloroetan (p,p‘- DDD) (0,001 – 5,0) mg/kg\no,p‘-dichlorodifenylodichloroetylen (o,p‘-DDE) (0,001 – 5,0) mg/kg\np,p‘-dichlorodifenylodichloroetylen (p,p‘-DDE) (0,001 – 5,0) mg/kg\nMetoksychlor (DMDT) (0,001 – 5,0) mg/kg\nEndosulfan I (0,001 – 5,0) mg/kg\nEndosulfan II (0,001 – 5,0) mg/kg\nAldehyd endryny (0,001 – 5,0) mg/kg\nChlordan (0,001 – 5,0) mg/kg\nSiarczan endosulfanu (0,001 – 5,0) mg/kg\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) EFO/PB/24/A z dnia 18.09.2023 r. | na podstawie normy: | PN-ISO 10382:2007 Osady denne, Gleba Zawartosc pestycydow\nZakres:\nAlachlor (0,001 – 5,0) mg/kg\nAldryna (0,001 – 5,0) mg/kg\nDieldryna (0,0005 – 5,0) mg/kg\nEndryna (0,001 – 5,0) mg/kg\nIzodryna (0,001 – 5,0) mg/kg\no,p-dichlorodifenylotrichloroetan (o,p’- DDT) (0,001 – 5,0) mg/kg\np,p’dichlorodifenylotrichloroetan (p,p’- DDT) (0,001 – 5,0) mg/kg\nα-heksachlorocykloheksan (α-HCH)\nZakres (0,0001 – 5,0) mg/kg\nβ-heksachlorocykloheksan (β-HCH) (0,0001 – 5,0) mg/kg\nγ-heksachlorocykloheksan (γ-HCH) (0,0001 – 5,0) mg/kg\nδ-heksachlorocykloheksan (δ-HCH) (0,0001 – 5,0) mg/kg\nHeksachlorobutadien (HCBD) (0,001 – 5,0) mg/kg\no,p‘- dichlorodifenylodichloroetan (o,p‘- DDD) (0,001 – 5,0) mg/kg\np,p‘- dichlorodifenylodichloroetan (p,p‘- DDD) (0,001 – 5,0) mg/kg\no,p‘-dichlorodifenylodichloroetylen (o,p‘-DDE) (0,001 – 5,0) mg/kg\np,p‘-dichlorodifenylodichloroetylen (p,p‘-DDE) (0,001 – 5,0) mg/kg\nMetoksychlor (DMDT) (0,001 – 5,0) mg/kg\nEndosulfan I (0,001 – 5,0) mg/kg\nEndosulfan II (0,001 – 5,0) mg/kg\nAldehyd endryny (0,001 – 5,0) mg/kg\nChlordan (0,001 – 5,0) mg/kg\nSiarczan endosulfanu (0,001 – 5,0) mg/kg\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) EFO/PB/24/A z dnia 18.09.2023 r. | na podstawie normy: | PN-ISO 10382:2007","categories":["water","environment"],"row_index":290,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pesticide content","parameters_en":[{"name":"Alachlor","range":"(0,001 – 5,0) mg/kg"},{"name":"Aldrin","range":"(0,001 – 5,0) mg/kg"},{"name":"Dieldrin","range":"(0,0005 – 5,0) mg/kg"},{"name":"Endrin","range":"(0,001 – 5,0) mg/kg"},{"name":"Isodrin","range":"(0,001 – 5,0) mg/kg"},{"name":"o,p-dichlorodiphenyltrichloroethane (o,p’- DDT)","range":"(0,001 – 5,0) mg/kg"},{"name":"p,p’dichlorodiphenyltrichloroethane (p,p’- DDT)","range":"(0,001 – 5,0) mg/kg"},{"name":"α-hexachlorocyclohexane (α-HCH)"},{"name":"Range","range":"(0,0001 – 5,0) mg/kg"},{"name":"β-hexachlorocyclohexane (β-HCH)","range":"(0,0001 – 5,0) mg/kg"},{"name":"γ-hexachlorocyclohexane (γ-HCH)","range":"(0,0001 – 5,0) mg/kg"},{"name":"δ-hexachlorocyclohexane (δ-HCH)","range":"(0,0001 – 5,0) mg/kg"},{"name":"Hexachlorobutadiene (HCBD)","range":"(0,001 – 5,0) mg/kg"},{"name":"o,p‘- dichlorodiphenyldichloroethane (o,p‘- DDD)","range":"(0,001 – 5,0) mg/kg"},{"name":"p,p‘- dichlorodiphenyldichloroethane (p,p‘- DDD)","range":"(0,001 – 5,0) mg/kg"},{"name":"o,p‘-dichlorodiphenyldichloroethylene (o,p‘-DDE)","range":"(0,001 – 5,0) mg/kg"},{"name":"p,p‘-dichlorodiphenyldichloroethylene (p,p‘-DDE)","range":"(0,001 – 5,0) mg/kg"},{"name":"Methoxychlor (DMDT)","range":"(0,001 – 5,0) mg/kg"},{"name":"Endosulfan I","range":"(0,001 – 5,0) mg/kg"},{"name":"Endosulfan II","range":"(0,001 – 5,0) mg/kg"},{"name":"Endrin aldehyde","range":"(0,001 – 5,0) mg/kg"},{"name":"Chlordane","range":"(0,001 – 5,0) mg/kg"},{"name":"Endosulfan sulfate","range":"(0,001 – 5,0) mg/kg"}],"search_en":"Bottom sediments, Soil Pesticide content Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) Alachlor Aldrin Dieldrin Endrin Isodrin o,p-dichlorodiphenyltrichloroethane (o,p’- DDT) p,p’dichlorodiphenyltrichloroethane (p,p’- DDT) α-hexachlorocyclohexane (α-HCH) Range β-hexachlorocyclohexane (β-HCH) γ-hexachlorocyclohexane (γ-HCH) δ-hexachlorocyclohexane (δ-HCH) Hexachlorobutadiene (HCBD) o,p‘- dichlorodiphenyldichloroethane (o,p‘- DDD) p,p‘- dichlorodiphenyldichloroethane (p,p‘- DDD) o,p‘-dichlorodiphenyldichloroethylene (o,p‘-DDE) p,p‘-dichlorodiphenyldichloroethylene (p,p‘-DDE) Methoxychlor (DMDT) Endosulfan I Endosulfan II Endrin aldehyde Chlordane Endosulfan sulfate EFO/PB/24/A z dnia 18.09.2023 r. | na podstawie normy: | PN-ISO 10382:2007","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","test_object_en":"Bottom sediments, Soil","parameters_zh":[{"name":"Alachlor","range":"(0,001 – 5,0) mg/kg"},{"name":"艾氏剂","range":"(0,001 – 5,0) mg/kg"},{"name":"狄氏剂","range":"(0,0005 – 5,0) mg/kg"},{"name":"异狄氏剂","range":"(0,001 – 5,0) mg/kg"},{"name":"异艾氏剂","range":"(0,001 – 5,0) mg/kg"},{"name":"o,p-dichlorodifenylotrichloroetan (o,p’- DDT)","range":"(0,001 – 5,0) mg/kg"},{"name":"p,p’dichlorodifenylotrichloroetan (p,p’- DDT)","range":"(0,001 – 5,0) mg/kg"},{"name":"α-六氯环己烷（α-HCH）"},{"name":"范围","range":"(0,0001 – 5,0) mg/kg"},{"name":"β-六氯环己烷（β-HCH）","range":"(0,0001 – 5,0) mg/kg"},{"name":"γ-heksachlorocykloheksan (γ-HCH)","range":"(0,0001 – 5,0) mg/kg"},{"name":"δ-六氯环己烷（δ-HCH）","range":"(0,0001 – 5,0) mg/kg"},{"name":"Heksachlorobutadien (HCBD)","range":"(0,001 – 5,0) mg/kg"},{"name":"o,p‘- dichlorodifenylodichloroetan (o,p‘- DDD)","range":"(0,001 – 5,0) mg/kg"},{"name":"p,p‘- dichlorodifenylodichloroetan (p,p‘- DDD)","range":"(0,001 – 5,0) mg/kg"},{"name":"o,p‘-dichlorodifenylodichloroetylen (o,p‘-DDE)","range":"(0,001 – 5,0) mg/kg"},{"name":"p,p‘-dichlorodifenylodichloroetylen (p,p‘-DDE)","range":"(0,001 – 5,0) mg/kg"},{"name":"Metoksychlor (DMDT)","range":"(0,001 – 5,0) mg/kg"},{"name":"Endosulfan I","range":"(0,001 – 5,0) mg/kg"},{"name":"Endosulfan II","range":"(0,001 – 5,0) mg/kg"},{"name":"异狄氏剂醛","range":"(0,001 – 5,0) mg/kg"},{"name":"Chlordan","range":"(0,001 – 5,0) mg/kg"},{"name":"硫酸盐硫丹","range":"(0,001 – 5,0) mg/kg"}],"search_zh":"底泥、土壤 农药含量 气相色谱-串联质谱法（GC-MS-MS） 艾氏剂 狄氏剂 异狄氏剂 异艾氏剂 α-六氯环己烷（α-HCH） 范围 β-六氯环己烷（β-HCH） δ-六氯环己烷（δ-HCH） 异狄氏剂醛 硫酸盐硫丹 EFO/PB/24/A z dnia 18.09.2023 r. | na podstawie normy: | PN-ISO 10382:2007","technique_zh":"气相色谱-串联质谱法（GC-MS-MS）","methodology_zh":"农药含量","test_object_zh":"底泥、土壤"},{"_id":"6a832b7f884ede9a1b2c55eb","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":291,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Sewage sludge pH Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"污泥 pH 值 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥"},{"_id":"6a832b7f884ede9a1b2c55ec","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Straty przy prażeniu (LOI) / substancje organiczne","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu (LOI) / substancje organiczne\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Straty przy prażeniu (LOI) / substancje organiczne\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe Straty przy prazeniu (LOI) / substancje organiczne\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["water"],"row_index":292,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition (LOI) / organic matter","parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"search_en":"Sewage sludge Loss on ignition (LOI) / organic matter Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"污泥 烧失量（LOI）/ 有机物质 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"烧失量（LOI）/ 有机物质"},{"_id":"6a832b7f884ede9a1b2c55ed","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Substancje mineralne (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Substancje mineralne (z obliczeń)","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Substancje mineralne (z obliczeń) PN-EN 15935:2022-01 Osady sciekowe Substancje mineralne (z obliczen) PN-EN 15935:2022-01","categories":["water"],"row_index":293,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral substances (calculated)","search_en":"Sewage sludge Mineral substances (calculated) PN-EN 15935:2022-01","test_object_en":"Sewage sludge","search_zh":"污泥 矿物质（由计算得出） PN-EN 15935:2022-01","test_object_zh":"污泥","methodology_zh":"矿物质（由计算得出）"},{"_id":"6a832b7f884ede9a1b2c55ee","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,010 – 12,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres (0,010 – 12,0) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu Kjeldahla\nZakres (0,010 – 12,0) %\nMetoda miareczkowa PN-EN 13342:2002 Osady sciekowe Zawartosc azotu Kjeldahla\nZakres (0,010 – 12,0) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["water"],"row_index":294,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,010 – 12,0) %"}],"search_en":"Sewage sludge Kjeldahl nitrogen content Titrimetric method Range PN-EN 13342:2002","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,010 – 12,0) %"}],"search_zh":"污泥 凯氏氮含量 滴定法 范围 PN-EN 13342:2002","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"凯氏氮含量"},{"_id":"6a832b7f884ede9a1b2c55ef","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,010 – 10,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (0,010 – 10,0) %\nMetoda miareczkowa","reference":"PN-75/C-04576/15","norm_bases":["PN-75/C-04576/15"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu amonowego\nZakres (0,010 – 10,0) %\nMetoda miareczkowa PN-75/C-04576/15 Osady sciekowe Zawartosc azotu amonowego\nZakres (0,010 – 10,0) %\nMetoda miareczkowa PN-75/C-04576/15","categories":["water"],"row_index":295,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,010 – 10,0) %"}],"search_en":"Sewage sludge Ammonium nitrogen content Titrimetric method Range PN-75/C-04576/15","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,010 – 10,0) %"}],"search_zh":"污泥 氨氮含量 滴定法 范围 PN-75/C-04576/15","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"氨氮含量"},{"_id":"6a832b7f884ede9a1b2c55f0","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu organicznego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość azotu organicznego (z obliczeń)","reference":"PB/FCH/15/D:10.04.2017","norm_bases":["PB/FCH/15/D:10.04.2017"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu organicznego (z obliczeń) PB/FCH/15/D:10.04.2017 Osady sciekowe Zawartosc azotu organicznego (z obliczen) PB/FCH/15/D:10.04.2017","categories":["water"],"row_index":296,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Organic nitrogen content (calculated)","search_en":"Sewage sludge Organic nitrogen content (calculated) PB/FCH/15/D:10.04.2017","test_object_en":"Sewage sludge","search_zh":"污泥 PB/FCH/15/D:10.04.2017","test_object_zh":"污泥"},{"_id":"6a832b7f884ede9a1b2c55f1","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,7 – 5,0) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu ogólnego\nZakres (0,7 – 5,0) %\nMetoda spektrofotometryczna","reference":"PN-EN 14672:2006","norm_bases":["PN-EN 14672:2006"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość fosforu ogólnego\nZakres (0,7 – 5,0) %\nMetoda spektrofotometryczna PN-EN 14672:2006 Osady sciekowe Zawartosc fosforu ogolnego\nZakres (0,7 – 5,0) %\nMetoda spektrofotometryczna PN-EN 14672:2006","categories":["water"],"row_index":297,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus content","parameters_en":[{"name":"Range","range":"(0,7 – 5,0) %"}],"search_en":"Sewage sludge Total phosphorus content Spectrophotometric method Range PN-EN 14672:2006","technique_en":"Spectrophotometric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,7 – 5,0) %"}],"search_zh":"污泥 总磷含量 分光光度法 范围 PN-EN 14672:2006","technique_zh":"分光光度法","test_object_zh":"污泥","methodology_zh":"总磷含量"},{"_id":"6a832b7f884ede9a1b2c55f2","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość rtęci","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość rtęci","reference":"PN-EN 16174:2012","norm_bases":["PN-EN 16174:2012"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość rtęci PN-EN 16174:2012 Osady sciekowe Zawartosc rteci PN-EN 16174:2012","categories":["water"],"row_index":298,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","search_en":"Sewage sludge Mercury content PN-EN 16174:2012","test_object_en":"Sewage sludge","methodology_zh":"汞含量","search_zh":"污泥 汞含量 PN-EN 16174:2012","test_object_zh":"污泥"},{"_id":"6a832b7f884ede9a1b2c55f3","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"","parameters":[{"name":"Zakres","range":"(0,05 – 25,0) mg/kg"}],"technique":null,"techniques":[],"computed":[],"activity":"Zakres (0,05 – 25,0) mg/kg","reference":"PN-EN ISO 12846:2012","norm_bases":["PN-EN ISO 12846:2012"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zakres (0,05 – 25,0) mg/kg PN-EN ISO 12846:2012 Osady sciekowe Zakres (0,05 – 25,0) mg/kg PN-EN ISO 12846:2012","categories":["water"],"row_index":299,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,05 – 25,0) mg/kg"}],"search_en":"Sewage sludge Range PN-EN ISO 12846:2012","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,05 – 25,0) mg/kg"}],"search_zh":"污泥 范围 PN-EN ISO 12846:2012","test_object_zh":"污泥"},{"_id":"6a832b7f884ede9a1b2c55f4","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"","parameters":[],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"+Ap1:2016-07","norm_bases":["+Ap1:2016-07"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) +Ap1:2016-07 Osady sciekowe Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) +Ap1:2016-07","categories":["water"],"row_index":300,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Sewage sludge Cold vapour atomic absorption spectrometry (CVAAS) +Ap1:2016-07","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Sewage sludge","search_zh":"污泥 冷蒸气原子吸收光谱法（CVAAS） +Ap1:2016-07","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"污泥"},{"_id":"6a832b7f884ede9a1b2c55f5","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha masa / zawartość wody","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa / zawartość wody\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02","norm_bases":["PN-EN 15934:2013-02"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha masa / zawartość wody\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15934:2013-02 Osady sciekowe Sucha masa / zawartosc wody\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15934:2013-02","categories":["water"],"row_index":301,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter / water content","parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"search_en":"Sewage sludge Dry matter / water content Gravimetric method Range PN-EN 15934:2013-02","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"污泥 干物质 / 水分含量 重量法 范围 PN-EN 15934:2013-02","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干物质 / 水分含量"},{"_id":"6a832b7f884ede9a1b2c55f6","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha masa / zawartość wody","parameters":[{"name":"Zakres","range":"(0,10 – 99,5) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Sucha masa / zawartość wody\nZakres (0,10 – 99,5) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN 15934:2013-02 Metoda A","norm_bases":["PN-EN 15934:2013-02 Metoda A"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha masa / zawartość wody\nZakres (0,10 – 99,5) %\nMetoda termograwimetryczna (TGA) PN-EN 15934:2013-02 Metoda A Osady sciekowe Sucha masa / zawartosc wody\nZakres (0,10 – 99,5) %\nMetoda termograwimetryczna (TGA) PN-EN 15934:2013-02 Metoda A","categories":["water"],"row_index":302,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter / water content","parameters_en":[{"name":"Range","range":"(0,10 – 99,5) %"}],"search_en":"Sewage sludge Dry matter / water content Thermogravimetric method (TGA) Range PN-EN 15934:2013-02 Metoda A","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,10 – 99,5) %"}],"search_zh":"污泥 干物质 / 水分含量 热重法（TGA） 范围 PN-EN 15934:2013-02 Metoda A","technique_zh":"热重法（TGA）","test_object_zh":"污泥","methodology_zh":"干物质 / 水分含量"},{"_id":"6a832b7f884ede9a1b2c55f7","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(7000 – 38000) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (7000 – 38000) kJ/kg\nMetoda kalorymetryczna","reference":"PN-EN ISO 18125:2017-07","norm_bases":["PN-EN ISO 18125:2017-07"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Ciepło spalania\nZakres (7000 – 38000) kJ/kg\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07 Paliwa stale: biomasa stala – biopaliwo stale Cieplo spalania\nZakres (7000 – 38000) kJ/kg\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07","categories":["petro"],"row_index":303,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(7000 – 38000) kJ/kg"}],"search_en":"Solid fuels: solid biomass – solid biofuel Gross calorific value Calorimetric method Range PN-EN ISO 18125:2017-07","technique_en":"Calorimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(7000 – 38000) kJ/kg"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 高位发热量 量热法 范围 PN-EN ISO 18125:2017-07","technique_zh":"量热法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a832b7f884ede9a1b2c55f8","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-EN ISO 18125:2017-07","norm_bases":["PN-EN ISO 18125:2017-07"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Wartość opałowa (z obliczeń) PN-EN ISO 18125:2017-07 Paliwa stale: biomasa stala – biopaliwo stale Wartosc opalowa (z obliczen) PN-EN ISO 18125:2017-07","categories":["petro"],"row_index":304,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Solid fuels: solid biomass – solid biofuel Net calorific value (calculated) PN-EN ISO 18125:2017-07","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology_zh":"低位发热量（计算值）","search_zh":"固体燃料：固体生物质 – 固体生物燃料 低位发热量（计算值） PN-EN ISO 18125:2017-07","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a832b7f884ede9a1b2c55f9","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość azotu (azotu Kjeldahla)","parameters":[{"name":"Zakres","range":"(0,002 – 8,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu (azotu Kjeldahla)\nZakres (0,002 – 8,0) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość azotu (azotu Kjeldahla)\nZakres (0,002 – 8,0) %\nMetoda miareczkowa PN-EN 13342:2002 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc azotu (azotu Kjeldahla)\nZakres (0,002 – 8,0) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["petro"],"row_index":305,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen (Kjeldahl nitrogen) content","parameters_en":[{"name":"Range","range":"(0,002 – 8,0) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Nitrogen (Kjeldahl nitrogen) content Titrimetric method Range PN-EN 13342:2002","technique_en":"Titrimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","parameters_zh":[{"name":"范围","range":"(0,002 – 8,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 滴定法 范围 PN-EN 13342:2002","technique_zh":"滴定法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a832b7f884ede9a1b2c55fa","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość chloru","parameters":[{"name":"Zakres","range":"(0,02 – 1,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość chloru\nZakres (0,02 – 1,0) %\nMetoda miareczkowa","reference":"PB/FCH/89/A:27.02.2014","norm_bases":["PB/FCH/89/A:27.02.2014"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość chloru\nZakres (0,02 – 1,0) %\nMetoda miareczkowa PB/FCH/89/A:27.02.2014 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc chloru\nZakres (0,02 – 1,0) %\nMetoda miareczkowa PB/FCH/89/A:27.02.2014","categories":["petro"],"row_index":306,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine content","parameters_en":[{"name":"Range","range":"(0,02 – 1,0) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Chlorine content Titrimetric method Range PB/FCH/89/A:27.02.2014","technique_en":"Titrimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","parameters_zh":[{"name":"范围","range":"(0,02 – 1,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 氯含量 滴定法 范围 PB/FCH/89/A:27.02.2014","technique_zh":"滴定法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","methodology_zh":"氯含量"},{"_id":"6a832b7f884ede9a1b2c55fb","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość części lotnych","parameters":[{"name":"Zakres","range":"(40,0 – 80,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość części lotnych\nZakres (40,0 – 80,0) %\nMetoda wagowa","reference":"PN-EN ISO 18123:2016-01","norm_bases":["PN-EN ISO 18123:2016-01"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość części lotnych\nZakres (40,0 – 80,0) %\nMetoda wagowa PN-EN ISO 18123:2016-01 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc czesci lotnych\nZakres (40,0 – 80,0) %\nMetoda wagowa PN-EN ISO 18123:2016-01","categories":["petro"],"row_index":307,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile matter content","parameters_en":[{"name":"Range","range":"(40,0 – 80,0) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Volatile matter content Gravimetric method Range PN-EN ISO 18123:2016-01","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","parameters_zh":[{"name":"范围","range":"(40,0 – 80,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 挥发分含量 重量法 范围 PN-EN ISO 18123:2016-01","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","methodology_zh":"挥发分含量"},{"_id":"6a832b7f884ede9a1b2c55fc","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość popiołu / pozostałość po spaleniu","parameters":[{"name":"Zakres","range":"(0,50 – 60,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu / pozostałość po spaleniu\nZakres (0,50 – 60,0) %\nMetoda wagowa","reference":"PN-EN ISO 18122:2016-01","norm_bases":["PN-EN ISO 18122:2016-01"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość popiołu / pozostałość po spaleniu\nZakres (0,50 – 60,0) %\nMetoda wagowa PN-EN ISO 18122:2016-01 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc popiolu / pozostalosc po spaleniu\nZakres (0,50 – 60,0) %\nMetoda wagowa PN-EN ISO 18122:2016-01","categories":["petro"],"row_index":308,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content / residue on ignition","parameters_en":[{"name":"Range","range":"(0,50 – 60,0) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Ash content / residue on ignition Gravimetric method Range PN-EN ISO 18122:2016-01","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","parameters_zh":[{"name":"范围","range":"(0,50 – 60,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 灰分含量/燃烧残渣 重量法 范围 PN-EN ISO 18122:2016-01","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","methodology_zh":"灰分含量/燃烧残渣"},{"_id":"6a832b7f884ede9a1b2c55fd","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość popiołu / pozostałość po spaleniu","parameters":[{"name":"Zakres","range":"(0,50 – 60,0) %"}],"technique":"Metoda termograwimetryczna","techniques":["Metoda termograwimetryczna"],"computed":[],"activity":"Zawartość popiołu / pozostałość po spaleniu\nZakres (0,50 – 60,0) %\nMetoda termograwimetryczna","reference":"PN-EN ISO 18122:2016-01","norm_bases":["PN-EN ISO 18122:2016-01"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość popiołu / pozostałość po spaleniu\nZakres (0,50 – 60,0) %\nMetoda termograwimetryczna PN-EN ISO 18122:2016-01 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc popiolu / pozostalosc po spaleniu\nZakres (0,50 – 60,0) %\nMetoda termograwimetryczna PN-EN ISO 18122:2016-01","categories":["petro"],"row_index":309,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content / residue on ignition","parameters_en":[{"name":"Range","range":"(0,50 – 60,0) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Ash content / residue on ignition Thermogravimetric method Range PN-EN ISO 18122:2016-01","technique_en":"Thermogravimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","parameters_zh":[{"name":"范围","range":"(0,50 – 60,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 灰分含量/燃烧残渣 热重法 范围 PN-EN ISO 18122:2016-01","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","technique_zh":"热重法","methodology_zh":"灰分含量/燃烧残渣"},{"_id":"6a832b7f884ede9a1b2c55fe","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(0,06 – 5,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość siarki\nZakres (0,06 – 5,0) %\nMetoda miareczkowa","reference":"PB/FCH/86/A:24.02.2014","norm_bases":["PB/FCH/86/A:24.02.2014"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość siarki\nZakres (0,06 – 5,0) %\nMetoda miareczkowa PB/FCH/86/A:24.02.2014 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc siarki\nZakres (0,06 – 5,0) %\nMetoda miareczkowa PB/FCH/86/A:24.02.2014","categories":["petro"],"row_index":310,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(0,06 – 5,0) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Sulfur content Titrimetric method Range PB/FCH/86/A:24.02.2014","technique_en":"Titrimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","parameters_zh":[{"name":"范围","range":"(0,06 – 5,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 硫含量 滴定法 范围 PB/FCH/86/A:24.02.2014","technique_zh":"滴定法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","methodology_zh":"硫含量"},{"_id":"6a832b7f884ede9a1b2c55ff","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,06 – 5,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,06 – 5,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16994:2016-10","norm_bases":["PN-EN ISO 16994:2016-10"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość siarki całkowitej\nZakres (0,06 – 5,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16994:2016-10 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc siarki calkowitej\nZakres (0,06 – 5,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16994:2016-10","categories":["petro"],"row_index":311,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,06 – 5,0) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Total sulfur content High-temperature combustion with IR detection Range PN-EN ISO 16994:2016-10","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,06 – 5,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 全硫含量 高温燃烧红外检测法 范围 PN-EN ISO 16994:2016-10","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a832b7f884ede9a1b2c5600","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość siarki popiołowej (z obliczeń) badane cechy/metoda","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość siarki popiołowej (z obliczeń) badane cechy/metoda","reference":"PB/FCH/87/B:29.08.2019 Dokumenty odniesienia","norm_bases":["PB/FCH/87/B:29.08.2019 Dokumenty odniesienia"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość siarki popiołowej (z obliczeń) badane cechy/metoda PB/FCH/87/B:29.08.2019 Dokumenty odniesienia Paliwa stale: biomasa stala – biopaliwo stale Zawartosc siarki popiolowej (z obliczen) badane cechy/metoda PB/FCH/87/B:29.08.2019 Dokumenty odniesienia","categories":["petro"],"row_index":312,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash sulphur content (calculated) tested features/method","search_en":"Solid fuels: solid biomass – solid biofuel Ash sulphur content (calculated) tested features/method PB/FCH/87/B:29.08.2019 Dokumenty odniesienia","test_object_en":"Solid fuels: solid biomass – solid biofuel","search_zh":"固体燃料：固体生物质 – 固体生物燃料 PB/FCH/87/B:29.08.2019 Dokumenty odniesienia","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a832b7f884ede9a1b2c5601","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość węgla, wodoru","parameters":[{"name":"węgiel","range":"(5,0 – 50,0) %"},{"name":"wodór","range":"(0,20 – 6,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla, wodoru\nZakres:\nwęgiel (5,0 – 50,0) %\nwodór (0,20 – 6,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość węgla, wodoru\nZakres:\nwęgiel (5,0 – 50,0) %\nwodór (0,20 – 6,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16948:2015-07 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wegla, wodoru\nZakres:\nwegiel (5,0 – 50,0) %\nwodor (0,20 – 6,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":313,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon, hydrogen content","parameters_en":[{"name":"carbon","range":"(5,0 – 50,0) %"},{"name":"hydrogen","range":"(0,20 – 6,0) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Carbon, hydrogen content High-temperature combustion with IR detection carbon hydrogen PN-EN ISO 16948:2015-07","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: solid biomass – solid biofuel","search_zh":"固体燃料：固体生物质 – 固体生物燃料 碳、氢含量 高温燃烧红外检测法 碳 氢 PN-EN ISO 16948:2015-07","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","parameters_zh":[{"name":"碳","range":"(5,0 – 50,0) %"},{"name":"氢","range":"(0,20 – 6,0) %"}],"methodology_zh":"碳、氢含量"},{"_id":"6a832b7f884ede9a1b2c5602","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(1,0 – 85,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (1,0 – 85,0) %\nMetoda wagowa","reference":"PN-EN ISO 18134-1:2023-02","norm_bases":["PN-EN ISO 18134-1:2023-02"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość wilgoci całkowitej\nZakres (1,0 – 85,0) %\nMetoda wagowa PN-EN ISO 18134-1:2023-02 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wilgoci calkowitej\nZakres (1,0 – 85,0) %\nMetoda wagowa PN-EN ISO 18134-1:2023-02","categories":["petro"],"row_index":314,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(1,0 – 85,0) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Total moisture content Gravimetric method Range PN-EN ISO 18134-1:2023-02","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 85,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 全水分含量 重量法 范围 PN-EN ISO 18134-1:2023-02","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a832b7f884ede9a1b2c5603","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość wilgoci przemijającej","parameters":[{"name":"Zakres","range":"(1,0 – 80,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci przemijającej\nZakres (1,0 – 80,0) %\nMetoda wagowa","reference":"EFO/PB/03/A:10.04.2022","norm_bases":["EFO/PB/03/A:10.04.2022"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość wilgoci przemijającej\nZakres (1,0 – 80,0) %\nMetoda wagowa EFO/PB/03/A:10.04.2022 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wilgoci przemijajacej\nZakres (1,0 – 80,0) %\nMetoda wagowa EFO/PB/03/A:10.04.2022","categories":["petro"],"row_index":315,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free moisture content","parameters_en":[{"name":"Range","range":"(1,0 – 80,0) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Free moisture content Gravimetric method Range EFO/PB/03/A:10.04.2022","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","parameters_zh":[{"name":"范围","range":"(1,0 – 80,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 外在水分含量 重量法 范围 EFO/PB/03/A:10.04.2022","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","methodology_zh":"外在水分含量"},{"_id":"6a832b7f884ede9a1b2c5604","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(1,0 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 40,0) %\nMetoda wagowa","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 40,0) %\nMetoda wagowa PN-EN ISO 18134-3:2023-12 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wilgoci w probce analitycznej\nZakres (1,0 – 40,0) %\nMetoda wagowa PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":316,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(1,0 – 40,0) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Moisture content in the analytical sample Gravimetric method Range PN-EN ISO 18134-3:2023-12","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 40,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 分析样品水分含量 重量法 范围 PN-EN ISO 18134-3:2023-12","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a832b7f884ede9a1b2c5605","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(1,0 – 40,0) %"}],"technique":"Metoda termograwimetryczna","techniques":["Metoda termograwimetryczna"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 40,0) %\nMetoda termograwimetryczna","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 40,0) %\nMetoda termograwimetryczna PN-EN ISO 18134-3:2023-12 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wilgoci w probce analitycznej\nZakres (1,0 – 40,0) %\nMetoda termograwimetryczna PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":317,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(1,0 – 40,0) %"}],"search_en":"Solid fuels: solid biomass – solid biofuel Moisture content in the analytical sample Thermogravimetric method Range PN-EN ISO 18134-3:2023-12","technique_en":"Thermogravimetric method","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 40,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 分析样品水分含量 热重法 范围 PN-EN ISO 18134-3:2023-12","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","technique_zh":"热重法"},{"_id":"6a832b7f884ede9a1b2c5606","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF)","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(7000 – 38000) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (7000 – 38000) kJ/kg\nMetoda kalorymetryczna","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF) Ciepło spalania\nZakres (7000 – 38000) kJ/kg\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12 Paliwa stale: stale paliwo wtorne (SRF) Cieplo spalania\nZakres (7000 – 38000) kJ/kg\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12","categories":["petro"],"row_index":318,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(7000 – 38000) kJ/kg"}],"search_en":"Solid fuels: solid recovered fuel (SRF) Gross calorific value Calorimetric method Range PN-EN ISO 21654:2021-12","technique_en":"Calorimetric method","test_object_en":"Solid fuels: solid recovered fuel (SRF)","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(7000 – 38000) kJ/kg"}],"search_zh":"固体燃料：固体再生燃料（SRF） 高位发热量 量热法 范围 PN-EN ISO 21654:2021-12","technique_zh":"量热法","test_object_zh":"固体燃料：固体再生燃料（SRF）"},{"_id":"6a832b7f884ede9a1b2c5607","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF)","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF) Wartość opałowa (z obliczeń) PN-EN ISO 21654:2021-12 Paliwa stale: stale paliwo wtorne (SRF) Wartosc opalowa (z obliczen) PN-EN ISO 21654:2021-12","categories":["petro"],"row_index":319,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Solid fuels: solid recovered fuel (SRF) Net calorific value (calculated) PN-EN ISO 21654:2021-12","test_object_en":"Solid fuels: solid recovered fuel (SRF)","methodology_zh":"低位发热量（计算值）","search_zh":"固体燃料：固体再生燃料（SRF） 低位发热量（计算值） PN-EN ISO 21654:2021-12","test_object_zh":"固体燃料：固体再生燃料（SRF）"},{"_id":"6a832b7f884ede9a1b2c5608","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF)","methodology":"Zawartość azotu (azotu Kjeldahla)","parameters":[{"name":"Zakres","range":"(0,002 – 8,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu (azotu Kjeldahla)\nZakres (0,002 – 8,0) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF) Zawartość azotu (azotu Kjeldahla)\nZakres (0,002 – 8,0) %\nMetoda miareczkowa PN-EN 13342:2002 Paliwa stale: stale paliwo wtorne (SRF) Zawartosc azotu (azotu Kjeldahla)\nZakres (0,002 – 8,0) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["petro"],"row_index":320,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen (Kjeldahl nitrogen) content","parameters_en":[{"name":"Range","range":"(0,002 – 8,0) %"}],"search_en":"Solid fuels: solid recovered fuel (SRF) Nitrogen (Kjeldahl nitrogen) content Titrimetric method Range PN-EN 13342:2002","technique_en":"Titrimetric method","test_object_en":"Solid fuels: solid recovered fuel (SRF)","parameters_zh":[{"name":"范围","range":"(0,002 – 8,0) %"}],"search_zh":"固体燃料：固体再生燃料（SRF） 滴定法 范围 PN-EN 13342:2002","technique_zh":"滴定法","test_object_zh":"固体燃料：固体再生燃料（SRF）"},{"_id":"6a832b7f884ede9a1b2c5609","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF)","methodology":"Zawartość chloru","parameters":[{"name":"Zakres","range":"(0,02 – 1,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość chloru\nZakres (0,02 – 1,0) %\nMetoda miareczkowa","reference":"PB/FCH/89/A:27.02.2014","norm_bases":["PB/FCH/89/A:27.02.2014"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF) Zawartość chloru\nZakres (0,02 – 1,0) %\nMetoda miareczkowa PB/FCH/89/A:27.02.2014 Paliwa stale: stale paliwo wtorne (SRF) Zawartosc chloru\nZakres (0,02 – 1,0) %\nMetoda miareczkowa PB/FCH/89/A:27.02.2014","categories":["petro"],"row_index":321,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine content","parameters_en":[{"name":"Range","range":"(0,02 – 1,0) %"}],"search_en":"Solid fuels: solid recovered fuel (SRF) Chlorine content Titrimetric method Range PB/FCH/89/A:27.02.2014","technique_en":"Titrimetric method","test_object_en":"Solid fuels: solid recovered fuel (SRF)","parameters_zh":[{"name":"范围","range":"(0,02 – 1,0) %"}],"search_zh":"固体燃料：固体再生燃料（SRF） 氯含量 滴定法 范围 PB/FCH/89/A:27.02.2014","technique_zh":"滴定法","methodology_zh":"氯含量","test_object_zh":"固体燃料：固体再生燃料（SRF）"},{"_id":"6a832b7f884ede9a1b2c560a","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF)","methodology":"Zawartość części lotnych","parameters":[{"name":"Zakres","range":"(2,0 – 90,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość części lotnych\nZakres (2,0 – 90,0) %\nMetoda wagowa","reference":"PN-EN ISO 22167:2021-08","norm_bases":["PN-EN ISO 22167:2021-08"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF) Zawartość części lotnych\nZakres (2,0 – 90,0) %\nMetoda wagowa PN-EN ISO 22167:2021-08 Paliwa stale: stale paliwo wtorne (SRF) Zawartosc czesci lotnych\nZakres (2,0 – 90,0) %\nMetoda wagowa PN-EN ISO 22167:2021-08","categories":["petro"],"row_index":322,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile matter content","parameters_en":[{"name":"Range","range":"(2,0 – 90,0) %"}],"search_en":"Solid fuels: solid recovered fuel (SRF) Volatile matter content Gravimetric method Range PN-EN ISO 22167:2021-08","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid recovered fuel (SRF)","parameters_zh":[{"name":"范围","range":"(2,0 – 90,0) %"}],"search_zh":"固体燃料：固体再生燃料（SRF） 挥发分含量 重量法 范围 PN-EN ISO 22167:2021-08","technique_zh":"重量法","methodology_zh":"挥发分含量","test_object_zh":"固体燃料：固体再生燃料（SRF）"},{"_id":"6a832b7f884ede9a1b2c560b","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF)","methodology":"Zawartość frakcji biodegradowalnej (zawartość biomasy)","parameters":[{"name":"Zakres","range":"(5,0 – 90,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość frakcji biodegradowalnej (zawartość biomasy)\nZakres (5,0 – 90,0) %\nMetoda wagowa","reference":"PN-EN ISO 21644:2021-07 annex B","norm_bases":["PN-EN ISO 21644:2021-07 annex B"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF) Zawartość frakcji biodegradowalnej (zawartość biomasy)\nZakres (5,0 – 90,0) %\nMetoda wagowa PN-EN ISO 21644:2021-07 annex B Paliwa stale: stale paliwo wtorne (SRF) Zawartosc frakcji biodegradowalnej (zawartosc biomasy)\nZakres (5,0 – 90,0) %\nMetoda wagowa PN-EN ISO 21644:2021-07 annex B","categories":["petro"],"row_index":323,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biodegradable fraction content (biomass content)","parameters_en":[{"name":"Range","range":"(5,0 – 90,0) %"}],"search_en":"Solid fuels: solid recovered fuel (SRF) Biodegradable fraction content (biomass content) Gravimetric method Range PN-EN ISO 21644:2021-07 annex B","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid recovered fuel (SRF)","parameters_zh":[{"name":"范围","range":"(5,0 – 90,0) %"}],"search_zh":"固体燃料：固体再生燃料（SRF） 重量法 范围 PN-EN ISO 21644:2021-07 annex B","technique_zh":"重量法","test_object_zh":"固体燃料：固体再生燃料（SRF）"},{"_id":"6a832b7f884ede9a1b2c560c","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF)","methodology":"Zawartość popiołu / pozostałość po spaleniu","parameters":[{"name":"Zakres","range":"(1,0 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu / pozostałość po spaleniu\nZakres (1,0 – 40,0) %\nMetoda wagowa","reference":"PN-EN ISO 21656:2021-08","norm_bases":["PN-EN ISO 21656:2021-08"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF) Zawartość popiołu / pozostałość po spaleniu\nZakres (1,0 – 40,0) %\nMetoda wagowa PN-EN ISO 21656:2021-08 Paliwa stale: stale paliwo wtorne (SRF) Zawartosc popiolu / pozostalosc po spaleniu\nZakres (1,0 – 40,0) %\nMetoda wagowa PN-EN ISO 21656:2021-08","categories":["petro"],"row_index":324,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content / residue on ignition","parameters_en":[{"name":"Range","range":"(1,0 – 40,0) %"}],"search_en":"Solid fuels: solid recovered fuel (SRF) Ash content / residue on ignition Gravimetric method Range PN-EN ISO 21656:2021-08","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid recovered fuel (SRF)","parameters_zh":[{"name":"范围","range":"(1,0 – 40,0) %"}],"search_zh":"固体燃料：固体再生燃料（SRF） 灰分含量/燃烧残渣 重量法 范围 PN-EN ISO 21656:2021-08","technique_zh":"重量法","test_object_zh":"固体燃料：固体再生燃料（SRF）","methodology_zh":"灰分含量/燃烧残渣"},{"_id":"6a832b7f884ede9a1b2c560d","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF)","methodology":"Zawartość popiołu / pozostałość po spaleniu","parameters":[{"name":"Zakres","range":"(1,0 – 40,0) %"}],"technique":"Metoda termograwimetryczna","techniques":["Metoda termograwimetryczna"],"computed":[],"activity":"Zawartość popiołu / pozostałość po spaleniu\nZakres (1,0 – 40,0) %\nMetoda termograwimetryczna","reference":"PN-EN ISO 21656:2021-08","norm_bases":["PN-EN ISO 21656:2021-08"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF) Zawartość popiołu / pozostałość po spaleniu\nZakres (1,0 – 40,0) %\nMetoda termograwimetryczna PN-EN ISO 21656:2021-08 Paliwa stale: stale paliwo wtorne (SRF) Zawartosc popiolu / pozostalosc po spaleniu\nZakres (1,0 – 40,0) %\nMetoda termograwimetryczna PN-EN ISO 21656:2021-08","categories":["petro"],"row_index":325,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content / residue on ignition","parameters_en":[{"name":"Range","range":"(1,0 – 40,0) %"}],"search_en":"Solid fuels: solid recovered fuel (SRF) Ash content / residue on ignition Thermogravimetric method Range PN-EN ISO 21656:2021-08","technique_en":"Thermogravimetric method","test_object_en":"Solid fuels: solid recovered fuel (SRF)","parameters_zh":[{"name":"范围","range":"(1,0 – 40,0) %"}],"search_zh":"固体燃料：固体再生燃料（SRF） 灰分含量/燃烧残渣 热重法 范围 PN-EN ISO 21656:2021-08","technique_zh":"热重法","test_object_zh":"固体燃料：固体再生燃料（SRF）","methodology_zh":"灰分含量/燃烧残渣"},{"_id":"6a832b7f884ede9a1b2c560e","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF)","methodology":"Zawartość siarki całkowitej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość siarki całkowitej","reference":"PN-EN 15408:2011","norm_bases":["PN-EN 15408:2011"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF) Zawartość siarki całkowitej PN-EN 15408:2011 Paliwa stale: stale paliwo wtorne (SRF) Zawartosc siarki calkowitej PN-EN 15408:2011","categories":["petro"],"row_index":326,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","search_en":"Solid fuels: solid recovered fuel (SRF) Total sulfur content PN-EN 15408:2011","test_object_en":"Solid fuels: solid recovered fuel (SRF)","methodology_zh":"全硫含量","search_zh":"固体燃料：固体再生燃料（SRF） 全硫含量 PN-EN 15408:2011","test_object_zh":"固体燃料：固体再生燃料（SRF）"},{"_id":"6a832b7f884ede9a1b2c560f","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF)","methodology":"","parameters":[{"name":"Zakres","range":"(0,20 – 2,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zakres (0,20 – 2,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PB/FCH/87/B:29.08.2019","norm_bases":["PB/FCH/87/B:29.08.2019"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF) Zakres (0,20 – 2,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PB/FCH/87/B:29.08.2019 Paliwa stale: stale paliwo wtorne (SRF) Zakres (0,20 – 2,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PB/FCH/87/B:29.08.2019","categories":["petro"],"row_index":327,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,20 – 2,0) %"}],"search_en":"Solid fuels: solid recovered fuel (SRF) High-temperature combustion with IR detection Range PB/FCH/87/B:29.08.2019","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: solid recovered fuel (SRF)","parameters_zh":[{"name":"范围","range":"(0,20 – 2,0) %"}],"search_zh":"固体燃料：固体再生燃料（SRF） 高温燃烧红外检测法 范围 PB/FCH/87/B:29.08.2019","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体再生燃料（SRF）"},{"_id":"6a832b7f884ede9a1b2c5610","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF)","methodology":"Zawartość siarki popiołowej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość siarki popiołowej (z obliczeń)","reference":"PB/FCH/87/B:29.08.2019","norm_bases":["PB/FCH/87/B:29.08.2019"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF) Zawartość siarki popiołowej (z obliczeń) PB/FCH/87/B:29.08.2019 Paliwa stale: stale paliwo wtorne (SRF) Zawartosc siarki popiolowej (z obliczen) PB/FCH/87/B:29.08.2019","categories":["petro"],"row_index":328,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash sulphur content (calculated)","search_en":"Solid fuels: solid recovered fuel (SRF) Ash sulphur content (calculated) PB/FCH/87/B:29.08.2019","test_object_en":"Solid fuels: solid recovered fuel (SRF)","search_zh":"固体燃料：固体再生燃料（SRF） PB/FCH/87/B:29.08.2019","test_object_zh":"固体燃料：固体再生燃料（SRF）"},{"_id":"6a832b7f884ede9a1b2c5611","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF)","methodology":"Zawartość węgla, wodoru","parameters":[{"name":"węgiel","range":"(5,0 – 80,0) %"},{"name":"wodór","range":"(0,20 – 15,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla, wodoru\nZakres:\nwęgiel (5,0 – 80,0) %\nwodór (0,20 – 15,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF) Zawartość węgla, wodoru\nZakres:\nwęgiel (5,0 – 80,0) %\nwodór (0,20 – 15,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 21663:2021-06 Paliwa stale: stale paliwo wtorne (SRF) Zawartosc wegla, wodoru\nZakres:\nwegiel (5,0 – 80,0) %\nwodor (0,20 – 15,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 21663:2021-06","categories":["petro"],"row_index":329,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon, hydrogen content","parameters_en":[{"name":"carbon","range":"(5,0 – 80,0) %"},{"name":"hydrogen","range":"(0,20 – 15,0) %"}],"search_en":"Solid fuels: solid recovered fuel (SRF) Carbon, hydrogen content High-temperature combustion with IR detection carbon hydrogen PN-EN ISO 21663:2021-06","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: solid recovered fuel (SRF)","search_zh":"固体燃料：固体再生燃料（SRF） 碳、氢含量 高温燃烧红外检测法 碳 氢 PN-EN ISO 21663:2021-06","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体再生燃料（SRF）","parameters_zh":[{"name":"碳","range":"(5,0 – 80,0) %"},{"name":"氢","range":"(0,20 – 15,0) %"}],"methodology_zh":"碳、氢含量"},{"_id":"6a832b7f884ede9a1b2c5612","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF)","methodology":"Zawartość wilgoci przemijającej","parameters":[{"name":"Zakres","range":"(1,5 – 40,0) %"}],"technique":"Metoda wagowa badane cechy/metoda","techniques":["Metoda wagowa badane cechy/metoda"],"computed":[],"activity":"Zawartość wilgoci przemijającej\nZakres (1,5 – 40,0) %\nMetoda wagowa badane cechy/metoda","reference":"EFO/PB/03/A: 10.04.2022 Dokumenty odniesienia","norm_bases":["EFO/PB/03/A: 10.04.2022 Dokumenty odniesienia"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF) Zawartość wilgoci przemijającej\nZakres (1,5 – 40,0) %\nMetoda wagowa badane cechy/metoda EFO/PB/03/A: 10.04.2022 Dokumenty odniesienia Paliwa stale: stale paliwo wtorne (SRF) Zawartosc wilgoci przemijajacej\nZakres (1,5 – 40,0) %\nMetoda wagowa badane cechy/metoda EFO/PB/03/A: 10.04.2022 Dokumenty odniesienia","categories":["petro"],"row_index":330,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free moisture content","parameters_en":[{"name":"Range","range":"(1,5 – 40,0) %"}],"search_en":"Solid fuels: solid recovered fuel (SRF) Free moisture content Gravimetric method tested characteristics/method Range EFO/PB/03/A: 10.04.2022 Dokumenty odniesienia","technique_en":"Gravimetric method tested characteristics/method","test_object_en":"Solid fuels: solid recovered fuel (SRF)","parameters_zh":[{"name":"范围","range":"(1,5 – 40,0) %"}],"search_zh":"固体燃料：固体再生燃料（SRF） 外在水分含量 范围 EFO/PB/03/A: 10.04.2022 Dokumenty odniesienia","methodology_zh":"外在水分含量","test_object_zh":"固体燃料：固体再生燃料（SRF）"},{"_id":"6a832b7f884ede9a1b2c5613","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF)","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,50 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,50 – 10,0) %\nMetoda wagowa","reference":"PN-EN ISO 21660-3:2021-08","norm_bases":["PN-EN ISO 21660-3:2021-08"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF) Zawartość wilgoci w próbce analitycznej\nZakres (0,50 – 10,0) %\nMetoda wagowa PN-EN ISO 21660-3:2021-08 Paliwa stale: stale paliwo wtorne (SRF) Zawartosc wilgoci w probce analitycznej\nZakres (0,50 – 10,0) %\nMetoda wagowa PN-EN ISO 21660-3:2021-08","categories":["petro"],"row_index":331,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,50 – 10,0) %"}],"search_en":"Solid fuels: solid recovered fuel (SRF) Moisture content in the analytical sample Gravimetric method Range PN-EN ISO 21660-3:2021-08","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid recovered fuel (SRF)","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,50 – 10,0) %"}],"search_zh":"固体燃料：固体再生燃料（SRF） 分析样品水分含量 重量法 范围 PN-EN ISO 21660-3:2021-08","technique_zh":"重量法","test_object_zh":"固体燃料：固体再生燃料（SRF）"},{"_id":"6a832b7f884ede9a1b2c5614","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF)","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,50 – 10,0) %"}],"technique":"Metoda termograwimetryczna","techniques":["Metoda termograwimetryczna"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,50 – 10,0) %\nMetoda termograwimetryczna","reference":"PN-EN ISO 21660-3:2021-08","norm_bases":["PN-EN ISO 21660-3:2021-08"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF) Zawartość wilgoci w próbce analitycznej\nZakres (0,50 – 10,0) %\nMetoda termograwimetryczna PN-EN ISO 21660-3:2021-08 Paliwa stale: stale paliwo wtorne (SRF) Zawartosc wilgoci w probce analitycznej\nZakres (0,50 – 10,0) %\nMetoda termograwimetryczna PN-EN ISO 21660-3:2021-08","categories":["petro"],"row_index":332,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,50 – 10,0) %"}],"search_en":"Solid fuels: solid recovered fuel (SRF) Moisture content in the analytical sample Thermogravimetric method Range PN-EN ISO 21660-3:2021-08","technique_en":"Thermogravimetric method","test_object_en":"Solid fuels: solid recovered fuel (SRF)","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,50 – 10,0) %"}],"search_zh":"固体燃料：固体再生燃料（SRF） 分析样品水分含量 热重法 范围 PN-EN ISO 21660-3:2021-08","technique_zh":"热重法","test_object_zh":"固体燃料：固体再生燃料（SRF）"},{"_id":"6a832b7f884ede9a1b2c5615","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF)","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(1,0 – 85,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (1,0 – 85,0) %\nMetoda wagowa","reference":"CEN/TS 15414-1:2010","norm_bases":["CEN/TS 15414-1:2010"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF) Zawartość wilgoci całkowitej\nZakres (1,0 – 85,0) %\nMetoda wagowa CEN/TS 15414-1:2010 Paliwa stale: stale paliwo wtorne (SRF) Zawartosc wilgoci calkowitej\nZakres (1,0 – 85,0) %\nMetoda wagowa CEN/TS 15414-1:2010","categories":["petro"],"row_index":333,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(1,0 – 85,0) %"}],"search_en":"Solid fuels: solid recovered fuel (SRF) Total moisture content Gravimetric method Range CEN/TS 15414-1:2010","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid recovered fuel (SRF)","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 85,0) %"}],"search_zh":"固体燃料：固体再生燃料（SRF） 全水分含量 重量法 范围 CEN/TS 15414-1:2010","technique_zh":"重量法","test_object_zh":"固体燃料：固体再生燃料（SRF）"},{"_id":"6a832b7f884ede9a1b2c5616","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: paliwo wtórne – paliwo alternatywne, biomasa stała – biopaliwo stałe","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,05 – 25,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,05 – 25,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PB/I/11/D:10.04.2020","norm_bases":["PB/I/11/D:10.04.2020"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: paliwo wtórne – paliwo alternatywne, biomasa stała – biopaliwo stałe Zawartość rtęci\nZakres (0,05 – 25,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PB/I/11/D:10.04.2020 Paliwa stale: paliwo wtorne – paliwo alternatywne, biomasa stala – biopaliwo stale Zawartosc rteci\nZakres (0,05 – 25,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PB/I/11/D:10.04.2020","categories":["petro"],"row_index":334,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,05 – 25,0) mg/kg"}],"search_en":"Solid fuels: secondary fuel – alternative fuel, solid biomass – solid biofuel Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range PB/I/11/D:10.04.2020","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Solid fuels: secondary fuel – alternative fuel, solid biomass – solid biofuel","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,05 – 25,0) mg/kg"}],"search_zh":"汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PB/I/11/D:10.04.2020","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a832b7f884ede9a1b2c5617","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby (polepszacze gleby) - podloza do upraw pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["other"],"row_index":335,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Plant cultivation aids: - soil improvers - growing media for cultivation pH Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Plant cultivation aids: - soil improvers - growing media for cultivation","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质 pH 值 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质"},{"_id":"6a832b7f884ede9a1b2c5618","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw","methodology":"Straty przy prażeniu (LOI) / substancje organiczne","parameters":[{"name":"Zakres","range":"(30,0 – 97,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu (LOI) / substancje organiczne\nZakres (30,0 – 97,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw Straty przy prażeniu (LOI) / substancje organiczne\nZakres (30,0 – 97,0) %\nMetoda wagowa PN-EN 15935:2022-01 Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby (polepszacze gleby) - podloza do upraw Straty przy prazeniu (LOI) / substancje organiczne\nZakres (30,0 – 97,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["other"],"row_index":336,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition (LOI) / organic matter","parameters_en":[{"name":"Range","range":"(30,0 – 97,0) %"}],"search_en":"Plant cultivation aids: - soil improvers - growing media for cultivation Loss on ignition (LOI) / organic matter Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Plant cultivation aids: - soil improvers - growing media for cultivation","parameters_zh":[{"name":"范围","range":"(30,0 – 97,0) %"}],"search_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质 烧失量（LOI）/ 有机物质 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质","methodology_zh":"烧失量（LOI）/ 有机物质"},{"_id":"6a832b7f884ede9a1b2c5619","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw","methodology":"Straty przy prażeniu (LOI) / substancje organiczne","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Straty przy prażeniu (LOI) / substancje organiczne\nZakres (0,5 – 99,5) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw Straty przy prażeniu (LOI) / substancje organiczne\nZakres (0,5 – 99,5) %\nMetoda termograwimetryczna (TGA) PN-EN 15935:2022-01 Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby (polepszacze gleby) - podloza do upraw Straty przy prazeniu (LOI) / substancje organiczne\nZakres (0,5 – 99,5) %\nMetoda termograwimetryczna (TGA) PN-EN 15935:2022-01","categories":["other"],"row_index":337,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition (LOI) / organic matter","parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"search_en":"Plant cultivation aids: - soil improvers - growing media for cultivation Loss on ignition (LOI) / organic matter Thermogravimetric method (TGA) Range PN-EN 15935:2022-01","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Plant cultivation aids: - soil improvers - growing media for cultivation","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质 烧失量（LOI）/ 有机物质 热重法（TGA） 范围 PN-EN 15935:2022-01","technique_zh":"热重法（TGA）","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质","methodology_zh":"烧失量（LOI）/ 有机物质"},{"_id":"6a832b7f884ede9a1b2c561a","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,070 – 9,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (0,070 – 9,0) %\nMetoda miareczkowa","reference":"PN-75/C-04576/15","norm_bases":["PN-75/C-04576/15"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw Zawartość azotu amonowego\nZakres (0,070 – 9,0) %\nMetoda miareczkowa PN-75/C-04576/15 Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby (polepszacze gleby) - podloza do upraw Zawartosc azotu amonowego\nZakres (0,070 – 9,0) %\nMetoda miareczkowa PN-75/C-04576/15","categories":["other"],"row_index":338,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,070 – 9,0) %"}],"search_en":"Plant cultivation aids: - soil improvers - growing media for cultivation Ammonium nitrogen content Titrimetric method Range PN-75/C-04576/15","technique_en":"Titrimetric method","test_object_en":"Plant cultivation aids: - soil improvers - growing media for cultivation","parameters_zh":[{"name":"范围","range":"(0,070 – 9,0) %"}],"search_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质 氨氮含量 滴定法 范围 PN-75/C-04576/15","technique_zh":"滴定法","methodology_zh":"氨氮含量","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质"},{"_id":"6a832b7f884ede9a1b2c561b","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw","methodology":"Zawartość azotu ogólnego Kjeldahla","parameters":[{"name":"Zakres","range":"(0,40 – 8,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu ogólnego Kjeldahla\nZakres (0,40 – 8,0) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw Zawartość azotu ogólnego Kjeldahla\nZakres (0,40 – 8,0) %\nMetoda miareczkowa PN-EN 13342:2002 Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby (polepszacze gleby) - podloza do upraw Zawartosc azotu ogolnego Kjeldahla\nZakres (0,40 – 8,0) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["other"],"row_index":339,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,40 – 8,0) %"}],"search_en":"Plant cultivation aids: - soil improvers - growing media for cultivation Total Kjeldahl nitrogen content Titrimetric method Range PN-EN 13342:2002","technique_en":"Titrimetric method","test_object_en":"Plant cultivation aids: - soil improvers - growing media for cultivation","parameters_zh":[{"name":"范围","range":"(0,40 – 8,0) %"}],"search_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质 凯氏总氮含量 滴定法 范围 PN-EN 13342:2002","technique_zh":"滴定法","methodology_zh":"凯氏总氮含量","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质"},{"_id":"6a832b7f884ede9a1b2c561c","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw","methodology":"Zawartość fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,25 – 0,70) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu ogólnego\nZakres (0,25 – 0,70) %\nMetoda spektrofotometryczna","reference":"PN-EN 14672:2006","norm_bases":["PN-EN 14672:2006"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw Zawartość fosforu ogólnego\nZakres (0,25 – 0,70) %\nMetoda spektrofotometryczna PN-EN 14672:2006 Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby (polepszacze gleby) - podloza do upraw Zawartosc fosforu ogolnego\nZakres (0,25 – 0,70) %\nMetoda spektrofotometryczna PN-EN 14672:2006","categories":["other"],"row_index":340,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus content","parameters_en":[{"name":"Range","range":"(0,25 – 0,70) %"}],"search_en":"Plant cultivation aids: - soil improvers - growing media for cultivation Total phosphorus content Spectrophotometric method Range PN-EN 14672:2006","technique_en":"Spectrophotometric method","test_object_en":"Plant cultivation aids: - soil improvers - growing media for cultivation","parameters_zh":[{"name":"范围","range":"(0,25 – 0,70) %"}],"search_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质 总磷含量 分光光度法 范围 PN-EN 14672:2006","technique_zh":"分光光度法","methodology_zh":"总磷含量","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质"},{"_id":"6a832b7f884ede9a1b2c561d","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw","methodology":"Sucha masa / zawartość wody","parameters":[{"name":"Zakres","range":"(5,0 – 95,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa / zawartość wody\nZakres (5,0 – 95,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 metoda A","norm_bases":["PN-EN 15934:2013-02 metoda A"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw Sucha masa / zawartość wody\nZakres (5,0 – 95,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby (polepszacze gleby) - podloza do upraw Sucha masa / zawartosc wody\nZakres (5,0 – 95,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A","categories":["water"],"row_index":341,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter / water content","parameters_en":[{"name":"Range","range":"(5,0 – 95,0) %"}],"search_en":"Plant cultivation aids: - soil improvers - growing media for cultivation Dry matter / water content Gravimetric method Range PN-EN 15934:2013-02 metoda A","technique_en":"Gravimetric method","test_object_en":"Plant cultivation aids: - soil improvers - growing media for cultivation","parameters_zh":[{"name":"范围","range":"(5,0 – 95,0) %"}],"search_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质 干物质 / 水分含量 重量法 范围 PN-EN 15934:2013-02 metoda A","technique_zh":"重量法","methodology_zh":"干物质 / 水分含量","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质"},{"_id":"6a832b7f884ede9a1b2c561e","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw","methodology":"Zawartość wody/ sucha masa","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość wody/ sucha masa\nZakres (0,5 – 99,5) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN 15934:2013-02 metoda A","norm_bases":["PN-EN 15934:2013-02 metoda A"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw Zawartość wody/ sucha masa\nZakres (0,5 – 99,5) %\nMetoda termograwimetryczna (TGA) PN-EN 15934:2013-02 metoda A Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby (polepszacze gleby) - podloza do upraw Zawartosc wody/ sucha masa\nZakres (0,5 – 99,5) %\nMetoda termograwimetryczna (TGA) PN-EN 15934:2013-02 metoda A","categories":["water"],"row_index":342,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content/ dry matter","parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"search_en":"Plant cultivation aids: - soil improvers - growing media for cultivation Water content/ dry matter Thermogravimetric method (TGA) Range PN-EN 15934:2013-02 metoda A","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Plant cultivation aids: - soil improvers - growing media for cultivation","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质 热重法（TGA） 范围 PN-EN 15934:2013-02 metoda A","technique_zh":"热重法（TGA）","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质"},{"_id":"6a832b7f884ede9a1b2c561f","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw","methodology":"Zawartość ogólnego węgla organicznego (TOC)","parameters":[{"name":"Zakres","range":"(0,10 – 60) %"},{"name":"Zakres","range":"(1000 – 600000) mg/kg"}],"technique":"Metoda wysoko temperaturowego spalania z detekcją IR","techniques":["Metoda wysoko temperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość ogólnego węgla organicznego (TOC)\nZakres:\nZakres (0,10 – 60) %\nZakres (1000 – 600000) mg/kg\nMetoda wysoko temperaturowego spalania z detekcją IR","reference":"PN EN 15936:2022-07","norm_bases":["PN EN 15936:2022-07"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw Zawartość ogólnego węgla organicznego (TOC)\nZakres:\nZakres (0,10 – 60) %\nZakres (1000 – 600000) mg/kg\nMetoda wysoko temperaturowego spalania z detekcją IR PN EN 15936:2022-07 Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby (polepszacze gleby) - podloza do upraw Zawartosc ogolnego wegla organicznego (TOC)\nZakres:\nZakres (0,10 – 60) %\nZakres (1000 – 600000) mg/kg\nMetoda wysoko temperaturowego spalania z detekcja IR PN EN 15936:2022-07","categories":["other"],"row_index":343,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon (TOC) content","parameters_en":[{"name":"Range","range":"(0,10 – 60) %"},{"name":"Range","range":"(1000 – 600000) mg/kg"}],"search_en":"Plant cultivation aids: - soil improvers - growing media for cultivation Total organic carbon (TOC) content High-temperature combustion with IR detection Range Range PN EN 15936:2022-07","technique_en":"High-temperature combustion with IR detection","test_object_en":"Plant cultivation aids: - soil improvers - growing media for cultivation","parameters_zh":[{"name":"范围","range":"(0,10 – 60) %"},{"name":"范围","range":"(1000 – 600000) mg/kg"}],"search_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质 总有机碳（TOC）含量 高温燃烧-红外检测法 范围 范围 PN EN 15936:2022-07","methodology_zh":"总有机碳（TOC）含量","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质","technique_zh":"高温燃烧-红外检测法"},{"_id":"6a832b7f884ede9a1b2c5620","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw","methodology":"Zawartość pierwiastków","parameters":[{"name":"fosfor jako P2O5","range":"(0,010 – 10) %"},{"name":"magnez jako MgO","range":"(0,010 – 12) %"},{"name":"potas jako K2O","range":"(0,010 – 25) %"},{"name":"sód jako Na2O","range":"(0,010 – 1,0) %"},{"name":"wapń jako CaO","range":"(0,010 – 20) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nfosfor jako P2O5 (0,010 – 10) %\nmagnez jako MgO (0,010 – 12) %\npotas jako K2O (0,010 – 25) %\nsód jako Na2O (0,010 – 1,0) %\nwapń jako CaO (0,010 – 20) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 15960: 2011 | PN-EN 15961:2017-02 | PN-EN ISO 11885:2009","norm_bases":["PN-EN 15960: 2011","PN-EN 15961:2017-02","PN-EN ISO 11885:2009"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw Zawartość pierwiastków\nZakres:\nfosfor jako P2O5 (0,010 – 10) %\nmagnez jako MgO (0,010 – 12) %\npotas jako K2O (0,010 – 25) %\nsód jako Na2O (0,010 – 1,0) %\nwapń jako CaO (0,010 – 20) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 15960: 2011 | PN-EN 15961:2017-02 | PN-EN ISO 11885:2009 Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby (polepszacze gleby) - podloza do upraw Zawartosc pierwiastkow\nZakres:\nfosfor jako P2O5 (0,010 – 10) %\nmagnez jako MgO (0,010 – 12) %\npotas jako K2O (0,010 – 25) %\nsod jako Na2O (0,010 – 1,0) %\nwapn jako CaO (0,010 – 20) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 15960: 2011 | PN-EN 15961:2017-02 | PN-EN ISO 11885:2009","categories":["other"],"row_index":344,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","parameters_en":[{"name":"phosphorus as P2O5","range":"(0,010 – 10) %"},{"name":"magnesium as MgO","range":"(0,010 – 12) %"},{"name":"potassium as K2O","range":"(0,010 – 25) %"},{"name":"sodium as Na2O","range":"(0,010 – 1,0) %"},{"name":"calcium as CaO","range":"(0,010 – 20) %"}],"search_en":"Plant cultivation aids: - soil improvers - growing media for cultivation Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) phosphorus as P2O5 magnesium as MgO potassium as K2O sodium as Na2O calcium as CaO PN-EN 15960: 2011 | PN-EN 15961:2017-02 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Plant cultivation aids: - soil improvers - growing media for cultivation","methodology_zh":"元素含量","search_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质 元素含量 电感耦合等离子体原子发射光谱法（ICP-OES） PN-EN 15960: 2011 | PN-EN 15961:2017-02 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质"},{"_id":"6a832b7f884ede9a1b2c5621","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw","methodology":"Zawartość pierwiastków","parameters":[{"name":"arsen","range":"(5,00 – 1000) mg/kg"},{"name":"bor","range":"(1,50 – 500) mg/kg"},{"name":"chrom","range":"(0,30 – 1000) mg/kg"},{"name":"cynk","range":"(0,50 – 10000) mg/kg"},{"name":"kadm","range":"(0,05 – 200) mg/kg"},{"name":"kobalt","range":"(0,20 – 200) mg/kg"},{"name":"mangan","range":"(0,10 – 500) mg/kg"},{"name":"miedź","range":"(0,40 – 5000) mg/kg"},{"name":"molibden","range":"(0,40 – 100) mg/kg"},{"name":"nikiel","range":"(0,40 – 1000) mg/kg"},{"name":"ołów","range":"(1,00 – 3000) mg/kg"},{"name":"żelazo","range":"(0,40 – 15000) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\narsen (5,00 – 1000) mg/kg\nbor (1,50 – 500) mg/kg\nchrom (0,30 – 1000) mg/kg\ncynk (0,50 – 10000) mg/kg\nkadm (0,05 – 200) mg/kg\nkobalt (0,20 – 200) mg/kg\nmangan (0,10 – 500) mg/kg\nmiedź (0,40 – 5000) mg/kg\nmolibden (0,40 – 100) mg/kg\nnikiel (0,40 – 1000) mg/kg\nołów (1,00 – 3000) mg/kg\nżelazo (0,40 – 15000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 16174 :2012 | PN-EN 22036:2024-07","norm_bases":["PN-EN 16174 :2012","PN-EN 22036:2024-07"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw Zawartość pierwiastków\nZakres:\narsen (5,00 – 1000) mg/kg\nbor (1,50 – 500) mg/kg\nchrom (0,30 – 1000) mg/kg\ncynk (0,50 – 10000) mg/kg\nkadm (0,05 – 200) mg/kg\nkobalt (0,20 – 200) mg/kg\nmangan (0,10 – 500) mg/kg\nmiedź (0,40 – 5000) mg/kg\nmolibden (0,40 – 100) mg/kg\nnikiel (0,40 – 1000) mg/kg\nołów (1,00 – 3000) mg/kg\nżelazo (0,40 – 15000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 16174 :2012 | PN-EN 22036:2024-07 Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby (polepszacze gleby) - podloza do upraw Zawartosc pierwiastkow\nZakres:\narsen (5,00 – 1000) mg/kg\nbor (1,50 – 500) mg/kg\nchrom (0,30 – 1000) mg/kg\ncynk (0,50 – 10000) mg/kg\nkadm (0,05 – 200) mg/kg\nkobalt (0,20 – 200) mg/kg\nmangan (0,10 – 500) mg/kg\nmiedz (0,40 – 5000) mg/kg\nmolibden (0,40 – 100) mg/kg\nnikiel (0,40 – 1000) mg/kg\nolow (1,00 – 3000) mg/kg\nzelazo (0,40 – 15000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 16174 :2012 | PN-EN 22036:2024-07","categories":["materials"],"row_index":345,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","parameters_en":[{"name":"arsenic","range":"(5,00 – 1000) mg/kg"},{"name":"boron","range":"(1,50 – 500) mg/kg"},{"name":"chromium","range":"(0,30 – 1000) mg/kg"},{"name":"zinc","range":"(0,50 – 10000) mg/kg"},{"name":"cadmium","range":"(0,05 – 200) mg/kg"},{"name":"cobalt","range":"(0,20 – 200) mg/kg"},{"name":"manganese","range":"(0,10 – 500) mg/kg"},{"name":"copper","range":"(0,40 – 5000) mg/kg"},{"name":"molybdenum","range":"(0,40 – 100) mg/kg"},{"name":"nickel","range":"(0,40 – 1000) mg/kg"},{"name":"lead","range":"(1,00 – 3000) mg/kg"},{"name":"iron","range":"(0,40 – 15000) mg/kg"}],"search_en":"Plant cultivation aids: - soil improvers - growing media for cultivation Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) arsenic boron chromium zinc cadmium cobalt manganese copper molybdenum nickel lead iron PN-EN 16174 :2012 | PN-EN 22036:2024-07","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Plant cultivation aids: - soil improvers - growing media for cultivation","methodology_zh":"元素含量","parameters_zh":[{"name":"砷","range":"(5,00 – 1000) mg/kg"},{"name":"硼","range":"(1,50 – 500) mg/kg"},{"name":"铬","range":"(0,30 – 1000) mg/kg"},{"name":"锌","range":"(0,50 – 10000) mg/kg"},{"name":"镉","range":"(0,05 – 200) mg/kg"},{"name":"钴","range":"(0,20 – 200) mg/kg"},{"name":"锰","range":"(0,10 – 500) mg/kg"},{"name":"铜","range":"(0,40 – 5000) mg/kg"},{"name":"钼","range":"(0,40 – 100) mg/kg"},{"name":"镍","range":"(0,40 – 1000) mg/kg"},{"name":"铅","range":"(1,00 – 3000) mg/kg"},{"name":"铁","range":"(0,40 – 15000) mg/kg"}],"search_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质 元素含量 电感耦合等离子体原子发射光谱法（ICP-OES） 砷 硼 铬 锌 镉 钴 锰 铜 钼 镍 铅 铁 PN-EN 16174 :2012 | PN-EN 22036:2024-07","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质"},{"_id":"6a832b7f884ede9a1b2c5622","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,05 – 3,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,05 – 3,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 16174:2012 | PN-EN 16175-1:2017-02","norm_bases":["PN-EN 16174:2012","PN-EN 16175-1:2017-02"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw Zawartość rtęci\nZakres (0,05 – 3,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 16174:2012 | PN-EN 16175-1:2017-02 Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby (polepszacze gleby) - podloza do upraw Zawartosc rteci\nZakres (0,05 – 3,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 16174:2012 | PN-EN 16175-1:2017-02","categories":["other"],"row_index":346,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,05 – 3,0) mg/kg"}],"search_en":"Plant cultivation aids: - soil improvers - growing media for cultivation Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 16174:2012 | PN-EN 16175-1:2017-02","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Plant cultivation aids: - soil improvers - growing media for cultivation","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,05 – 3,0) mg/kg"}],"search_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质 汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 16174:2012 | PN-EN 16175-1:2017-02","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质"},{"_id":"6a832b7f884ede9a1b2c5623","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobrane do roztworu pochłaniającego - próbki gazów składowiskowych pobrane do roztworu pochłaniającego - próbki biogazu pobrane do roztworu pochłaniającego","methodology":"Zawartość amoniaku NH3","parameters":[{"name":"Zakres","range":"(0,005 – 2,6) mg w próbce"}],"technique":"Metoda przepływowej analizy ciągłej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda przepływowej analizy ciągłej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość amoniaku NH3\nZakres (0,005 – 2,6) mg w próbce\nMetoda przepływowej analizy ciągłej (CFA) z detekcją spektrofotometryczną","reference":"PB/FCH/5/C:30.03.2012","norm_bases":["PB/FCH/5/C:30.03.2012"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobrane do roztworu pochłaniającego - próbki gazów składowiskowych pobrane do roztworu pochłaniającego - próbki biogazu pobrane do roztworu pochłaniającego Zawartość amoniaku NH3\nZakres (0,005 – 2,6) mg w próbce\nMetoda przepływowej analizy ciągłej (CFA) z detekcją spektrofotometryczną PB/FCH/5/C:30.03.2012 Srodowisko ogolne - probki gazow odlotowych pobrane do roztworu pochlaniajacego - probki gazow skladowiskowych pobrane do roztworu pochlaniajacego - probki biogazu pobrane do roztworu pochlaniajacego Zawartosc amoniaku NH3\nZakres (0,005 – 2,6) mg w probce\nMetoda przeplywowej analizy ciaglej (CFA) z detekcja spektrofotometryczna PB/FCH/5/C:30.03.2012","categories":["environment"],"row_index":347,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia NH3 content","parameters_en":[{"name":"Range","range":"(0,005 – 2,6) mg w próbce"}],"search_en":"General environment - waste gas samples collected into absorbing solution - landfill gas samples collected into absorbing solution - biogas samples collected into absorbing solution Ammonia NH3 content Continuous flow analysis (CFA) with spectrophotometric detection Range PB/FCH/5/C:30.03.2012","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"General environment - waste gas samples collected into absorbing solution - landfill gas samples collected into absorbing solution - biogas samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,005 – 2,6) mg w próbce"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 － 采集于吸收液中的填埋气样品 － 采集于吸收液中的沼气样品 范围 PB/FCH/5/C:30.03.2012","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品 － 采集于吸收液中的填埋气样品 － 采集于吸收液中的沼气样品"},{"_id":"6a832b7f884ede9a1b2c5624","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobrane do roztworu pochłaniającego - próbki gazów składowiskowych pobrane do roztworu pochłaniającego - próbki biogazu pobrane do roztworu pochłaniającego","methodology":"Zawartość chlorowodoru HCl","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość chlorowodoru HCl","reference":"PB/FCH/55/C:30.09.2021","norm_bases":["PB/FCH/55/C:30.09.2021"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobrane do roztworu pochłaniającego - próbki gazów składowiskowych pobrane do roztworu pochłaniającego - próbki biogazu pobrane do roztworu pochłaniającego Zawartość chlorowodoru HCl PB/FCH/55/C:30.09.2021 Srodowisko ogolne - probki gazow odlotowych pobrane do roztworu pochlaniajacego - probki gazow skladowiskowych pobrane do roztworu pochlaniajacego - probki biogazu pobrane do roztworu pochlaniajacego Zawartosc chlorowodoru HCl PB/FCH/55/C:30.09.2021","categories":["environment"],"row_index":348,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen chloride HCl content","search_en":"General environment - waste gas samples collected into absorbing solution - landfill gas samples collected into absorbing solution - biogas samples collected into absorbing solution Hydrogen chloride HCl content PB/FCH/55/C:30.09.2021","test_object_en":"General environment - waste gas samples collected into absorbing solution - landfill gas samples collected into absorbing solution - biogas samples collected into absorbing solution","search_zh":"一般环境 － 采集于吸收液中的排放气体样品 － 采集于吸收液中的填埋气样品 － 采集于吸收液中的沼气样品 PB/FCH/55/C:30.09.2021","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品 － 采集于吸收液中的填埋气样品 － 采集于吸收液中的沼气样品"},{"_id":"6a832b7f884ede9a1b2c5625","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobrane do roztworu pochłaniającego - próbki gazów składowiskowych pobrane do roztworu pochłaniającego - próbki biogazu pobrane do roztworu pochłaniającego","methodology":"","parameters":[{"name":"Zakres","range":"(0,10 – 30,0) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zakres (0,10 – 30,0) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobrane do roztworu pochłaniającego - próbki gazów składowiskowych pobrane do roztworu pochłaniającego - próbki biogazu pobrane do roztworu pochłaniającego Zakres (0,10 – 30,0) mg w próbce\nMetoda spektrofotometryczna PN-EN 1911:2011 Srodowisko ogolne - probki gazow odlotowych pobrane do roztworu pochlaniajacego - probki gazow skladowiskowych pobrane do roztworu pochlaniajacego - probki biogazu pobrane do roztworu pochlaniajacego Zakres (0,10 – 30,0) mg w probce\nMetoda spektrofotometryczna PN-EN 1911:2011","categories":["environment"],"row_index":349,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,10 – 30,0) mg w próbce"}],"search_en":"General environment - waste gas samples collected into absorbing solution - landfill gas samples collected into absorbing solution - biogas samples collected into absorbing solution Spectrophotometric method Range PN-EN 1911:2011","technique_en":"Spectrophotometric method","test_object_en":"General environment - waste gas samples collected into absorbing solution - landfill gas samples collected into absorbing solution - biogas samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,10 – 30,0) mg w próbce"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 － 采集于吸收液中的填埋气样品 － 采集于吸收液中的沼气样品 分光光度法 范围 PN-EN 1911:2011","technique_zh":"分光光度法","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品 － 采集于吸收液中的填埋气样品 － 采集于吸收液中的沼气样品"},{"_id":"6a832b7f884ede9a1b2c5626","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobrane do roztworu pochłaniającego - próbki gazów składowiskowych pobrane do roztworu pochłaniającego - próbki biogazu pobrane do roztworu pochłaniającego","methodology":"Zawartość dwutlenku siarki SO2","parameters":[{"name":"Zakres","range":"(0,20 – 150) mg w próbce"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość dwutlenku siarki SO2\nZakres (0,20 – 150) mg w próbce\nMetoda miareczkowa","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobrane do roztworu pochłaniającego - próbki gazów składowiskowych pobrane do roztworu pochłaniającego - próbki biogazu pobrane do roztworu pochłaniającego Zawartość dwutlenku siarki SO2\nZakres (0,20 – 150) mg w próbce\nMetoda miareczkowa PN-EN 14791:2017-04 Srodowisko ogolne - probki gazow odlotowych pobrane do roztworu pochlaniajacego - probki gazow skladowiskowych pobrane do roztworu pochlaniajacego - probki biogazu pobrane do roztworu pochlaniajacego Zawartosc dwutlenku siarki SO2\nZakres (0,20 – 150) mg w probce\nMetoda miareczkowa PN-EN 14791:2017-04","categories":["environment"],"row_index":350,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur dioxide SO2 content","parameters_en":[{"name":"Range","range":"(0,20 – 150) mg w próbce"}],"search_en":"General environment - waste gas samples collected into absorbing solution - landfill gas samples collected into absorbing solution - biogas samples collected into absorbing solution Sulfur dioxide SO2 content Titrimetric method Range PN-EN 14791:2017-04","technique_en":"Titrimetric method","test_object_en":"General environment - waste gas samples collected into absorbing solution - landfill gas samples collected into absorbing solution - biogas samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,20 – 150) mg w próbce"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 － 采集于吸收液中的填埋气样品 － 采集于吸收液中的沼气样品 滴定法 范围 PN-EN 14791:2017-04","technique_zh":"滴定法","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品 － 采集于吸收液中的填埋气样品 － 采集于吸收液中的沼气样品"},{"_id":"6a832b7f884ede9a1b2c5627","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobrane do roztworu pochłaniającego - próbki gazów składowiskowych pobrane do roztworu pochłaniającego - próbki biogazu pobrane do roztworu pochłaniającego","methodology":"Zawartość fluorowodoru HF","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość fluorowodoru HF","reference":"PB/FCH/58/C:30.09.2021","norm_bases":["PB/FCH/58/C:30.09.2021"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobrane do roztworu pochłaniającego - próbki gazów składowiskowych pobrane do roztworu pochłaniającego - próbki biogazu pobrane do roztworu pochłaniającego Zawartość fluorowodoru HF PB/FCH/58/C:30.09.2021 Srodowisko ogolne - probki gazow odlotowych pobrane do roztworu pochlaniajacego - probki gazow skladowiskowych pobrane do roztworu pochlaniajacego - probki biogazu pobrane do roztworu pochlaniajacego Zawartosc fluorowodoru HF PB/FCH/58/C:30.09.2021","categories":["environment"],"row_index":351,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen fluoride HF content","search_en":"General environment - waste gas samples collected into absorbing solution - landfill gas samples collected into absorbing solution - biogas samples collected into absorbing solution Hydrogen fluoride HF content PB/FCH/58/C:30.09.2021","test_object_en":"General environment - waste gas samples collected into absorbing solution - landfill gas samples collected into absorbing solution - biogas samples collected into absorbing solution","search_zh":"一般环境 － 采集于吸收液中的排放气体样品 － 采集于吸收液中的填埋气样品 － 采集于吸收液中的沼气样品 PB/FCH/58/C:30.09.2021","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品 － 采集于吸收液中的填埋气样品 － 采集于吸收液中的沼气样品"},{"_id":"6a832b7f884ede9a1b2c5628","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobrane do roztworu pochłaniającego - próbki gazów składowiskowych pobrane do roztworu pochłaniającego - próbki biogazu pobrane do roztworu pochłaniającego","methodology":"","parameters":[{"name":"Zakres","range":"(0,05 – 50,0) mg w próbce"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Zakres (0,05 – 50,0) mg w próbce\nMetoda potencjometryczna","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobrane do roztworu pochłaniającego - próbki gazów składowiskowych pobrane do roztworu pochłaniającego - próbki biogazu pobrane do roztworu pochłaniającego Zakres (0,05 – 50,0) mg w próbce\nMetoda potencjometryczna ISO 15713:2006 Srodowisko ogolne - probki gazow odlotowych pobrane do roztworu pochlaniajacego - probki gazow skladowiskowych pobrane do roztworu pochlaniajacego - probki biogazu pobrane do roztworu pochlaniajacego Zakres (0,05 – 50,0) mg w probce\nMetoda potencjometryczna ISO 15713:2006","categories":["environment"],"row_index":352,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,05 – 50,0) mg w próbce"}],"search_en":"General environment - waste gas samples collected into absorbing solution - landfill gas samples collected into absorbing solution - biogas samples collected into absorbing solution Potentiometric method Range ISO 15713:2006","technique_en":"Potentiometric method","test_object_en":"General environment - waste gas samples collected into absorbing solution - landfill gas samples collected into absorbing solution - biogas samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,05 – 50,0) mg w próbce"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 － 采集于吸收液中的填埋气样品 － 采集于吸收液中的沼气样品 电位法 范围 ISO 15713:2006","technique_zh":"电位法","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品 － 采集于吸收液中的填埋气样品 － 采集于吸收液中的沼气样品"},{"_id":"6a832b7f884ede9a1b2c5629","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobrane do roztworu pochłaniającego - próbki gazów składowiskowych pobrane do roztworu pochłaniającego - próbki biogazu pobrane do roztworu pochłaniającego","methodology":"Zawartość kwasu siarkowego i trójtlenku siarki H2SO4 i SO3","parameters":[{"name":"Zakres","range":"(0,05 – 100) mg w próbce"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość kwasu siarkowego i trójtlenku siarki H2SO4 i SO3\nZakres (0,05 – 100) mg w próbce\nMetoda miareczkowa","reference":"PB/FCH/44/C:30.09.2021","norm_bases":["PB/FCH/44/C:30.09.2021"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobrane do roztworu pochłaniającego - próbki gazów składowiskowych pobrane do roztworu pochłaniającego - próbki biogazu pobrane do roztworu pochłaniającego Zawartość kwasu siarkowego i trójtlenku siarki H2SO4 i SO3\nZakres (0,05 – 100) mg w próbce\nMetoda miareczkowa PB/FCH/44/C:30.09.2021 Srodowisko ogolne - probki gazow odlotowych pobrane do roztworu pochlaniajacego - probki gazow skladowiskowych pobrane do roztworu pochlaniajacego - probki biogazu pobrane do roztworu pochlaniajacego Zawartosc kwasu siarkowego i trojtlenku siarki H2SO4 i SO3\nZakres (0,05 – 100) mg w probce\nMetoda miareczkowa PB/FCH/44/C:30.09.2021","categories":["environment"],"row_index":353,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulphuric acid and sulphur trioxide H2SO4 and SO3 content","parameters_en":[{"name":"Range","range":"(0,05 – 100) mg w próbce"}],"search_en":"General environment - waste gas samples collected into absorbing solution - landfill gas samples collected into absorbing solution - biogas samples collected into absorbing solution Sulphuric acid and sulphur trioxide H2SO4 and SO3 content Titrimetric method Range PB/FCH/44/C:30.09.2021","technique_en":"Titrimetric method","test_object_en":"General environment - waste gas samples collected into absorbing solution - landfill gas samples collected into absorbing solution - biogas samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,05 – 100) mg w próbce"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 － 采集于吸收液中的填埋气样品 － 采集于吸收液中的沼气样品 滴定法 范围 PB/FCH/44/C:30.09.2021","technique_zh":"滴定法","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品 － 采集于吸收液中的填埋气样品 － 采集于吸收液中的沼气样品"},{"_id":"6a832b7f884ede9a1b2c562a","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobrane do roztworu pochłaniającego - próbki gazów składowiskowych pobrane do roztworu pochłaniającego - próbki biogazu pobrane do roztworu pochłaniającego","methodology":"Zawartość siarkowodoru H2S","parameters":[{"name":"Zakres","range":"(0,20 – 200) mg w próbce"}],"technique":"Metoda miareczkowa badane cechy/metoda","techniques":["Metoda miareczkowa badane cechy/metoda"],"computed":[],"activity":"Zawartość siarkowodoru H2S\nZakres (0,20 – 200) mg w próbce\nMetoda miareczkowa badane cechy/metoda","reference":"PB/FCH/43/C:30.09.2021 Dokumenty odniesienia","norm_bases":["PB/FCH/43/C:30.09.2021 Dokumenty odniesienia"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobrane do roztworu pochłaniającego - próbki gazów składowiskowych pobrane do roztworu pochłaniającego - próbki biogazu pobrane do roztworu pochłaniającego Zawartość siarkowodoru H2S\nZakres (0,20 – 200) mg w próbce\nMetoda miareczkowa badane cechy/metoda PB/FCH/43/C:30.09.2021 Dokumenty odniesienia Srodowisko ogolne - probki gazow odlotowych pobrane do roztworu pochlaniajacego - probki gazow skladowiskowych pobrane do roztworu pochlaniajacego - probki biogazu pobrane do roztworu pochlaniajacego Zawartosc siarkowodoru H2S\nZakres (0,20 – 200) mg w probce\nMetoda miareczkowa badane cechy/metoda PB/FCH/43/C:30.09.2021 Dokumenty odniesienia","categories":["environment"],"row_index":354,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen sulphide content H2S","parameters_en":[{"name":"Range","range":"(0,20 – 200) mg w próbce"}],"search_en":"General environment - waste gas samples collected into absorbing solution - landfill gas samples collected into absorbing solution - biogas samples collected into absorbing solution Hydrogen sulphide content H2S Titrimetric method tested characteristics/method Range PB/FCH/43/C:30.09.2021 Dokumenty odniesienia","technique_en":"Titrimetric method tested characteristics/method","test_object_en":"General environment - waste gas samples collected into absorbing solution - landfill gas samples collected into absorbing solution - biogas samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,20 – 200) mg w próbce"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 － 采集于吸收液中的填埋气样品 － 采集于吸收液中的沼气样品 范围 PB/FCH/43/C:30.09.2021 Dokumenty odniesienia","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品 － 采集于吸收液中的填埋气样品 － 采集于吸收液中的沼气样品"},{"_id":"6a832b7f884ede9a1b2c562b","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko ogólne: - próbki powietrza pobrane do roztworu pochłaniającego, - próbki powietrza pobrane na filtry","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,25 – 500) μg w próbce"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,25 – 500) μg w próbce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 15852:2010","norm_bases":["PN-EN 15852:2010"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne: - próbki powietrza pobrane do roztworu pochłaniającego, - próbki powietrza pobrane na filtry Stężenie rtęci\nZakres (0,25 – 500) μg w próbce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 15852:2010 Srodowisko ogolne: - probki powietrza pobrane do roztworu pochlaniajacego, - probki powietrza pobrane na filtry Stezenie rteci\nZakres (0,25 – 500) μg w probce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 15852:2010","categories":["environment"],"row_index":355,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,25 – 500) μg w próbce"}],"search_en":"General environment: - air samples collected into absorbing solution, - air samples collected on filters Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 15852:2010","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"General environment: - air samples collected into absorbing solution, - air samples collected on filters","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,25 – 500) μg w próbce"}],"search_zh":"汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 15852:2010","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a832b7f884ede9a1b2c562c","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko ogólne: - próbki gazów odlotowych pobrane do roztworu pochłaniającego, - próbki gazów odlotowych pobrane na filtry","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,10 – 500) μg w próbce"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,10 – 500) μg w próbce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne: - próbki gazów odlotowych pobrane do roztworu pochłaniającego, - próbki gazów odlotowych pobrane na filtry Stężenie rtęci\nZakres (0,10 – 500) μg w próbce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 13211+AC:2006 Srodowisko ogolne: - probki gazow odlotowych pobrane do roztworu pochlaniajacego, - probki gazow odlotowych pobrane na filtry Stezenie rteci\nZakres (0,10 – 500) μg w probce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 13211+AC:2006","categories":["environment"],"row_index":356,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,10 – 500) μg w próbce"}],"search_en":"General environment: - waste gas samples collected into absorbing solution, - waste gas samples collected on filters Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 13211+AC:2006","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"General environment: - waste gas samples collected into absorbing solution, - waste gas samples collected on filters","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 500) μg w próbce"}],"search_zh":"汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 13211+AC:2006","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a832b7f884ede9a1b2c562d","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry i na rurki z sorbentem","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"antracen (0,010 – 8,0) μg w próbce benzo(a)antracen"},{"name":"Zakres","range":"(0,010 – 8,0) μg w próbce"},{"name":"chryzen (0,010 – 8,0) μg w próbce benzo(b)fluoranten (0,010 – 8,0) μg w próbce benzo(k)fluoranten (0,010 – 8.0) μg w próbce benzo(a)piren (0,010 – 8,0) μg w próbce dibenzo(a,h)antracen (0,010 – 8,0) μg w próbce benzo(g,h,i)perylen (0,010 – 8,0) μg w próbce indeno","range":"(1,2,3-c,d)piren"},{"name":"(0,010 – 8,0) μg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nantracen (0,010 – 8,0) μg w próbce benzo(a)antracen\nZakres (0,010 – 8,0) μg w próbce\nchryzen (0,010 – 8,0) μg w próbce benzo(b)fluoranten (0,010 – 8,0) μg w próbce benzo(k)fluoranten (0,010 – 8.0) μg w próbce benzo(a)piren (0,010 – 8,0) μg w próbce dibenzo(a,h)antracen (0,010 – 8,0) μg w próbce benzo(g,h,i)perylen (0,010 – 8,0) μg w próbce indeno (1,2,3-c,d)piren\n(0,010 – 8,0) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-Z-04240-5:2006","norm_bases":["PN-Z-04240-5:2006"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry i na rurki z sorbentem Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nantracen (0,010 – 8,0) μg w próbce benzo(a)antracen\nZakres (0,010 – 8,0) μg w próbce\nchryzen (0,010 – 8,0) μg w próbce benzo(b)fluoranten (0,010 – 8,0) μg w próbce benzo(k)fluoranten (0,010 – 8.0) μg w próbce benzo(a)piren (0,010 – 8,0) μg w próbce dibenzo(a,h)antracen (0,010 – 8,0) μg w próbce benzo(g,h,i)perylen (0,010 – 8,0) μg w próbce indeno (1,2,3-c,d)piren\n(0,010 – 8,0) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-Z-04240-5:2006 Srodowisko pracy – powietrze – probki powietrza pobrane na filtry i na rurki z sorbentem Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nantracen (0,010 – 8,0) μg w probce benzo(a)antracen\nZakres (0,010 – 8,0) μg w probce\nchryzen (0,010 – 8,0) μg w probce benzo(b)fluoranten (0,010 – 8,0) μg w probce benzo(k)fluoranten (0,010 – 8.0) μg w probce benzo(a)piren (0,010 – 8,0) μg w probce dibenzo(a,h)antracen (0,010 – 8,0) μg w probce benzo(g,h,i)perylen (0,010 – 8,0) μg w probce indeno (1,2,3-c,d)piren\n(0,010 – 8,0) μg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-Z-04240-5:2006","categories":["environment"],"row_index":357,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polycyclic aromatic hydrocarbons (PAH) content","parameters_en":[{"name":"anthracene (0,010 – 8,0) μg in the sample benzo(a)anthracene"},{"name":"Range","range":"(0,010 – 8,0) μg w próbce"},{"name":"chrysene (0,010 – 8,0) μg in the sample benzo(b)fluoranthene (0,010 – 8,0) μg in the sample benzo(k)fluoranthene (0,010 – 8.0) μg in the sample benzo(a)pyrene (0,010 – 8,0) μg in the sample dibenzo(a,h)anthracene (0,010 – 8,0) μg in the sample benzo(g,h,i)perylene (0,010 – 8,0) μg in the sample indeno","range":"(1,2,3-c,d)piren"},{"name":"(0,010 – 8,0) μg in the sample"}],"search_en":"Workplace environment – air – air samples collected on filters and on sorbent tubes Polycyclic aromatic hydrocarbons (PAH) content High-performance liquid chromatography with fluorescence detection (HPLC-FLD) anthracene (0,010 – 8,0) μg in the sample benzo(a)anthracene Range chrysene (0,010 – 8,0) μg in the sample benzo(b)fluoranthene (0,010 – 8,0) μg in the sample benzo(k)fluoranthene (0,010 – 8.0) μg in the sample benzo(a)pyrene (0,010 – 8,0) μg in the sample dibenzo(a,h)anthracene (0,010 – 8,0) μg in the sample benzo(g,h,i)perylene (0,010 – 8,0) μg in the sample indeno (0,010 – 8,0) μg in the sample PN-Z-04240-5:2006","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Workplace environment – air – air samples collected on filters and on sorbent tubes","parameters_zh":[{"name":"antracen (0,010 – 8,0) μg w próbce benzo(a)antracen"},{"name":"范围","range":"(0,010 – 8,0) μg w próbce"},{"name":"chryzen (0,010 – 8,0) μg w próbce benzo(b)fluoranten (0,010 – 8,0) μg w próbce benzo(k)fluoranten (0,010 – 8.0) μg w próbce benzo(a)piren (0,010 – 8,0) μg w próbce dibenzo(a,h)antracen (0,010 – 8,0) μg w próbce benzo(g,h,i)perylen (0,010 – 8,0) μg w próbce indeno","range":"(1,2,3-c,d)piren"},{"name":"(0,010 – 8,0) μg w próbce"}],"search_zh":"多环芳烃（PAHs）含量 高效液相色谱-荧光检测法（HPLC-FLD） 范围 PN-Z-04240-5:2006","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","methodology_zh":"多环芳烃（PAHs）含量"},{"_id":"6a832b7f884ede9a1b2c562e","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry","methodology":"Zawartość benzo(a)pirenu","parameters":[{"name":"Zakres","range":"(0,010 – 8,0) μg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość benzo(a)pirenu\nZakres (0,010 – 8,0) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-Z-04240-2:1999","norm_bases":["PN-Z-04240-2:1999"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry Zawartość benzo(a)pirenu\nZakres (0,010 – 8,0) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-Z-04240-2:1999 Srodowisko pracy – powietrze – probki powietrza pobrane na filtry Zawartosc benzo(a)pirenu\nZakres (0,010 – 8,0) μg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-Z-04240-2:1999","categories":["environment"],"row_index":358,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Benzo(a)pyrene content","parameters_en":[{"name":"Range","range":"(0,010 – 8,0) μg w próbce"}],"search_en":"Workplace environment – air – air samples collected on filters Benzo(a)pyrene content High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Range PN-Z-04240-2:1999","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Workplace environment – air – air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,010 – 8,0) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 苯并(a)芘含量 高效液相色谱-荧光检测法（HPLC-FLD） 范围 PN-Z-04240-2:1999","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","methodology_zh":"苯并(a)芘含量"},{"_id":"6a832b7f884ede9a1b2c562f","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry","methodology":"Zawartość dibenzo(a,h)antracenu","parameters":[{"name":"Zakres","range":"(0,010 – 10) μg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość dibenzo(a,h)antracenu\nZakres (0,010 – 10) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-Z-04240-4:1999","norm_bases":["PN-Z-04240-4:1999"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry Zawartość dibenzo(a,h)antracenu\nZakres (0,010 – 10) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-Z-04240-4:1999 Srodowisko pracy – powietrze – probki powietrza pobrane na filtry Zawartosc dibenzo(a,h)antracenu\nZakres (0,010 – 10) μg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-Z-04240-4:1999","categories":["environment"],"row_index":359,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dibenzo(a,h)anthracene content","parameters_en":[{"name":"Range","range":"(0,010 – 10) μg w próbce"}],"search_en":"Workplace environment – air – air samples collected on filters Dibenzo(a,h)anthracene content High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Range PN-Z-04240-4:1999","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Workplace environment – air – air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,010 – 10) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 高效液相色谱-荧光检测法（HPLC-FLD） 范围 PN-Z-04240-4:1999","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品"},{"_id":"6a832b7f884ede9a1b2c5630","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry","methodology":"Zawartość metali i ich związków","parameters":[{"name":"wodorotlenek potasu"},{"name":"Zakres","range":"(0,018 – 0,72) mg w próbce"},{"name":"wodorotlenek sodu (0,018 – 0,72) mg w próbce cyna i jej związki nieorganiczne z wyjątkiem stannanu, w przeliczeniu na Sn - frakcja wdychalna (0,072 – 2,88) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali i ich związków\nZakres:\nwodorotlenek potasu\nZakres (0,018 – 0,72) mg w próbce\nwodorotlenek sodu (0,018 – 0,72) mg w próbce cyna i jej związki nieorganiczne z wyjątkiem stannanu, w przeliczeniu na Sn - frakcja wdychalna (0,072 – 2,88) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"EFO/PB/45/E:22.10.2025","norm_bases":["EFO/PB/45/E:22.10.2025"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry Zawartość metali i ich związków\nZakres:\nwodorotlenek potasu\nZakres (0,018 – 0,72) mg w próbce\nwodorotlenek sodu (0,018 – 0,72) mg w próbce cyna i jej związki nieorganiczne z wyjątkiem stannanu, w przeliczeniu na Sn - frakcja wdychalna (0,072 – 2,88) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) EFO/PB/45/E:22.10.2025 Srodowisko pracy – powietrze – probki powietrza pobrane na filtry Zawartosc metali i ich zwiazkow\nZakres:\nwodorotlenek potasu\nZakres (0,018 – 0,72) mg w probce\nwodorotlenek sodu (0,018 – 0,72) mg w probce cyna i jej zwiazki nieorganiczne z wyjatkiem stannanu, w przeliczeniu na Sn - frakcja wdychalna (0,072 – 2,88) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) EFO/PB/45/E:22.10.2025","categories":["materials","environment"],"row_index":360,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"wodorotlenek potasu"},{"name":"Range","range":"(0,018 – 0,72) mg w próbce"},{"name":"wodorotlenek sodu (0,018 – 0,72) mg w próbce cyna i jej związki nieorganiczne z wyjątkiem stannanu, w przeliczeniu na Sn - frakcja wdychalna (0,072 – 2,88) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected on filters Inductively coupled plasma optical emission spectrometry (ICP-OES) Range EFO/PB/45/E:22.10.2025","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Workplace environment – air – air samples collected on filters","parameters_zh":[{"name":"wodorotlenek potasu"},{"name":"范围","range":"(0,018 – 0,72) mg w próbce"},{"name":"wodorotlenek sodu (0,018 – 0,72) mg w próbce cyna i jej związki nieorganiczne z wyjątkiem stannanu, w przeliczeniu na Sn - frakcja wdychalna (0,072 – 2,88) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 EFO/PB/45/E:22.10.2025","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品"},{"_id":"6a832b7f884ede9a1b2c5631","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry","methodology":"Zawartość metali i ich związków","parameters":[{"name":"srebro - frakcja wdychalna"},{"name":"Zakres","range":"(0,0018 – 0,072) mg w próbce"},{"name":"tlenki żelaza w przeliczeniu na Fe, tlenek żelaza (III), tlenk żelaza (II), tetratlenk triżelaza - frakcja wdychalna, frakcja respirabilna (0,085 – 7,20) mg w próbce mangan i jego związki nieorganiczne w przeliczeniu na Mn - frakcja wdychalna, frakcja respirabilna (0,0018 – 0,288) mg w próbce związki niklu - w przeliczeniu na Ni - frakcja wdychalna, frakcja respirabilna (0,00036 – 0,072) mg w próbce nikiel metaliczny (0,0090 – 0,36) mg w próbce tlenki cynku w przeliczeniu na Zn - frakcja wdychalna (0,18 – 7,20) mg w próbce kadm i jego związki nieorganiczne w przeliczeniu na Cd - frakcja wdychalna (0,000050 – 0,00144) mg w próbce miedz i jej związki nieorganicznych w przeliczeniu na Cu (0,0084– 0,288) mg w próbce ołów i jego związki nieorganiczne w przeliczeniu na Pb - frakcja wdychalna (0,0018 – 0,072) mg w próbce kobalt i jego związki nieorganiczne w przeliczeniu na Co (0,00072 – 0,0288) mg w próbce glin metaliczny, glin proszek (niestabilizowany) - frakcja wdychalna, frakcja respirabilna (0,0342 – 3,60) mg w próbce chrom metaliczny, związki chromu (II), chrom (III), chrom (VI) w przeliczeniu na chrom (0,018 – 0,72) mg w próbce arsen i jego związki nieorganiczne w przeliczeniu na As – frakcja wdychalna (0,0036 – 0,0144) mg w próbce tlenek magnezu - frakcja wdychalna (0,36 – 14,4) mg w próbce tlenek wapnia - frakcja wdychalna, frakcja respirabilna (0,0342 - 2,88) mg w próbce węglan wapnia - frakcja wdychalna (0,36 – 14,4) mg w próbce wodorotlenek wapnia - frakcja wdychalna, frakcja respirabilna (0,0342 – 4,32) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali i ich związków\nZakres:\nsrebro - frakcja wdychalna\nZakres (0,0018 – 0,072) mg w próbce\ntlenki żelaza w przeliczeniu na Fe, tlenek żelaza (III), tlenk żelaza (II), tetratlenk triżelaza - frakcja wdychalna, frakcja respirabilna (0,085 – 7,20) mg w próbce mangan i jego związki nieorganiczne w przeliczeniu na Mn - frakcja wdychalna, frakcja respirabilna (0,0018 – 0,288) mg w próbce związki niklu - w przeliczeniu na Ni - frakcja wdychalna, frakcja respirabilna (0,00036 – 0,072) mg w próbce nikiel metaliczny (0,0090 – 0,36) mg w próbce tlenki cynku w przeliczeniu na Zn - frakcja wdychalna (0,18 – 7,20) mg w próbce kadm i jego związki nieorganiczne w przeliczeniu na Cd - frakcja wdychalna (0,000050 – 0,00144) mg w próbce miedz i jej związki nieorganicznych w przeliczeniu na Cu (0,0084– 0,288) mg w próbce ołów i jego związki nieorganiczne w przeliczeniu na Pb - frakcja wdychalna (0,0018 – 0,072) mg w próbce kobalt i jego związki nieorganiczne w przeliczeniu na Co (0,00072 – 0,0288) mg w próbce glin metaliczny, glin proszek (niestabilizowany) - frakcja wdychalna, frakcja respirabilna (0,0342 – 3,60) mg w próbce chrom metaliczny, związki chromu (II), chrom (III), chrom (VI) w przeliczeniu na chrom (0,018 – 0,72) mg w próbce arsen i jego związki nieorganiczne w przeliczeniu na As – frakcja wdychalna (0,0036 – 0,0144) mg w próbce tlenek magnezu - frakcja wdychalna (0,36 – 14,4) mg w próbce tlenek wapnia - frakcja wdychalna, frakcja respirabilna (0,0342 - 2,88) mg w próbce węglan wapnia - frakcja wdychalna (0,36 – 14,4) mg w próbce wodorotlenek wapnia - frakcja wdychalna, frakcja respirabilna (0,0342 – 4,32) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"EFO/PB/45/E:22.10.2025","norm_bases":["EFO/PB/45/E:22.10.2025"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry Zawartość metali i ich związków\nZakres:\nsrebro - frakcja wdychalna\nZakres (0,0018 – 0,072) mg w próbce\ntlenki żelaza w przeliczeniu na Fe, tlenek żelaza (III), tlenk żelaza (II), tetratlenk triżelaza - frakcja wdychalna, frakcja respirabilna (0,085 – 7,20) mg w próbce mangan i jego związki nieorganiczne w przeliczeniu na Mn - frakcja wdychalna, frakcja respirabilna (0,0018 – 0,288) mg w próbce związki niklu - w przeliczeniu na Ni - frakcja wdychalna, frakcja respirabilna (0,00036 – 0,072) mg w próbce nikiel metaliczny (0,0090 – 0,36) mg w próbce tlenki cynku w przeliczeniu na Zn - frakcja wdychalna (0,18 – 7,20) mg w próbce kadm i jego związki nieorganiczne w przeliczeniu na Cd - frakcja wdychalna (0,000050 – 0,00144) mg w próbce miedz i jej związki nieorganicznych w przeliczeniu na Cu (0,0084– 0,288) mg w próbce ołów i jego związki nieorganiczne w przeliczeniu na Pb - frakcja wdychalna (0,0018 – 0,072) mg w próbce kobalt i jego związki nieorganiczne w przeliczeniu na Co (0,00072 – 0,0288) mg w próbce glin metaliczny, glin proszek (niestabilizowany) - frakcja wdychalna, frakcja respirabilna (0,0342 – 3,60) mg w próbce chrom metaliczny, związki chromu (II), chrom (III), chrom (VI) w przeliczeniu na chrom (0,018 – 0,72) mg w próbce arsen i jego związki nieorganiczne w przeliczeniu na As – frakcja wdychalna (0,0036 – 0,0144) mg w próbce tlenek magnezu - frakcja wdychalna (0,36 – 14,4) mg w próbce tlenek wapnia - frakcja wdychalna, frakcja respirabilna (0,0342 - 2,88) mg w próbce węglan wapnia - frakcja wdychalna (0,36 – 14,4) mg w próbce wodorotlenek wapnia - frakcja wdychalna, frakcja respirabilna (0,0342 – 4,32) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) EFO/PB/45/E:22.10.2025 Srodowisko pracy – powietrze – probki powietrza pobrane na filtry Zawartosc metali i ich zwiazkow\nZakres:\nsrebro - frakcja wdychalna\nZakres (0,0018 – 0,072) mg w probce\ntlenki zelaza w przeliczeniu na Fe, tlenek zelaza (III), tlenk zelaza (II), tetratlenk trizelaza - frakcja wdychalna, frakcja respirabilna (0,085 – 7,20) mg w probce mangan i jego zwiazki nieorganiczne w przeliczeniu na Mn - frakcja wdychalna, frakcja respirabilna (0,0018 – 0,288) mg w probce zwiazki niklu - w przeliczeniu na Ni - frakcja wdychalna, frakcja respirabilna (0,00036 – 0,072) mg w probce nikiel metaliczny (0,0090 – 0,36) mg w probce tlenki cynku w przeliczeniu na Zn - frakcja wdychalna (0,18 – 7,20) mg w probce kadm i jego zwiazki nieorganiczne w przeliczeniu na Cd - frakcja wdychalna (0,000050 – 0,00144) mg w probce miedz i jej zwiazki nieorganicznych w przeliczeniu na Cu (0,0084– 0,288) mg w probce olow i jego zwiazki nieorganiczne w przeliczeniu na Pb - frakcja wdychalna (0,0018 – 0,072) mg w probce kobalt i jego zwiazki nieorganiczne w przeliczeniu na Co (0,00072 – 0,0288) mg w probce glin metaliczny, glin proszek (niestabilizowany) - frakcja wdychalna, frakcja respirabilna (0,0342 – 3,60) mg w probce chrom metaliczny, zwiazki chromu (II), chrom (III), chrom (VI) w przeliczeniu na chrom (0,018 – 0,72) mg w probce arsen i jego zwiazki nieorganiczne w przeliczeniu na As – frakcja wdychalna (0,0036 – 0,0144) mg w probce tlenek magnezu - frakcja wdychalna (0,36 – 14,4) mg w probce tlenek wapnia - frakcja wdychalna, frakcja respirabilna (0,0342 - 2,88) mg w probce weglan wapnia - frakcja wdychalna (0,36 – 14,4) mg w probce wodorotlenek wapnia - frakcja wdychalna, frakcja respirabilna (0,0342 – 4,32) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) EFO/PB/45/E:22.10.2025","categories":["materials","environment"],"row_index":361,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"srebro - frakcja wdychalna"},{"name":"Range","range":"(0,0018 – 0,072) mg w próbce"},{"name":"tlenki żelaza w przeliczeniu na Fe, tlenek żelaza (III), tlenk żelaza (II), tetratlenk triżelaza - frakcja wdychalna, frakcja respirabilna (0,085 – 7,20) mg w próbce mangan i jego związki nieorganiczne w przeliczeniu na Mn - frakcja wdychalna, frakcja respirabilna (0,0018 – 0,288) mg w próbce związki niklu - w przeliczeniu na Ni - frakcja wdychalna, frakcja respirabilna (0,00036 – 0,072) mg w próbce nikiel metaliczny (0,0090 – 0,36) mg w próbce tlenki cynku w przeliczeniu na Zn - frakcja wdychalna (0,18 – 7,20) mg w próbce kadm i jego związki nieorganiczne w przeliczeniu na Cd - frakcja wdychalna (0,000050 – 0,00144) mg w próbce miedz i jej związki nieorganicznych w przeliczeniu na Cu (0,0084– 0,288) mg w próbce ołów i jego związki nieorganiczne w przeliczeniu na Pb - frakcja wdychalna (0,0018 – 0,072) mg w próbce kobalt i jego związki nieorganiczne w przeliczeniu na Co (0,00072 – 0,0288) mg w próbce glin metaliczny, glin proszek (niestabilizowany) - frakcja wdychalna, frakcja respirabilna (0,0342 – 3,60) mg w próbce chrom metaliczny, związki chromu (II), chrom (III), chrom (VI) w przeliczeniu na chrom (0,018 – 0,72) mg w próbce arsen i jego związki nieorganiczne w przeliczeniu na As – frakcja wdychalna (0,0036 – 0,0144) mg w próbce tlenek magnezu - frakcja wdychalna (0,36 – 14,4) mg w próbce tlenek wapnia - frakcja wdychalna, frakcja respirabilna (0,0342 - 2,88) mg w próbce węglan wapnia - frakcja wdychalna (0,36 – 14,4) mg w próbce wodorotlenek wapnia - frakcja wdychalna, frakcja respirabilna (0,0342 – 4,32) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected on filters Inductively coupled plasma optical emission spectrometry (ICP-OES) Range EFO/PB/45/E:22.10.2025","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Workplace environment – air – air samples collected on filters","parameters_zh":[{"name":"srebro - frakcja wdychalna"},{"name":"范围","range":"(0,0018 – 0,072) mg w próbce"},{"name":"tlenki żelaza w przeliczeniu na Fe, tlenek żelaza (III), tlenk żelaza (II), tetratlenk triżelaza - frakcja wdychalna, frakcja respirabilna (0,085 – 7,20) mg w próbce mangan i jego związki nieorganiczne w przeliczeniu na Mn - frakcja wdychalna, frakcja respirabilna (0,0018 – 0,288) mg w próbce związki niklu - w przeliczeniu na Ni - frakcja wdychalna, frakcja respirabilna (0,00036 – 0,072) mg w próbce nikiel metaliczny (0,0090 – 0,36) mg w próbce tlenki cynku w przeliczeniu na Zn - frakcja wdychalna (0,18 – 7,20) mg w próbce kadm i jego związki nieorganiczne w przeliczeniu na Cd - frakcja wdychalna (0,000050 – 0,00144) mg w próbce miedz i jej związki nieorganicznych w przeliczeniu na Cu (0,0084– 0,288) mg w próbce ołów i jego związki nieorganiczne w przeliczeniu na Pb - frakcja wdychalna (0,0018 – 0,072) mg w próbce kobalt i jego związki nieorganiczne w przeliczeniu na Co (0,00072 – 0,0288) mg w próbce glin metaliczny, glin proszek (niestabilizowany) - frakcja wdychalna, frakcja respirabilna (0,0342 – 3,60) mg w próbce chrom metaliczny, związki chromu (II), chrom (III), chrom (VI) w przeliczeniu na chrom (0,018 – 0,72) mg w próbce arsen i jego związki nieorganiczne w przeliczeniu na As – frakcja wdychalna (0,0036 – 0,0144) mg w próbce tlenek magnezu - frakcja wdychalna (0,36 – 14,4) mg w próbce tlenek wapnia - frakcja wdychalna, frakcja respirabilna (0,0342 - 2,88) mg w próbce węglan wapnia - frakcja wdychalna (0,36 – 14,4) mg w próbce wodorotlenek wapnia - frakcja wdychalna, frakcja respirabilna (0,0342 – 4,32) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 EFO/PB/45/E:22.10.2025","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品"},{"_id":"6a832b7f884ede9a1b2c5632","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko ogólne: - próbki gazów odlotowych pobrane na filtry, na rurki z sorbentem","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"Naftalen (0,050 – 5,0) μg w próbce acenaften (0,050 – 5,0) μg w próbce fenantren (0,050 – 5,0) μg w próbce fluoranten (0,050 – 5,0) μg w próbce benzo(a)antracen"},{"name":"Zakres","range":"(0,050 – 5,0) μg w próbce"},{"name":"benzo(k)fluoranten (0,050 – 5,0) μg w próbce benzo(a)piren (0,050 – 5,0) μg w próbce dibenzo(a,h)antracen (0,050 – 5,0) μg w próbce fluoren (0,050 – 5,0) μg w próbce antracen (0,050 – 5,0) μg w próbce piren (0,050 – 5,0) μg w próbce chryzen (0,050 – 5,0) μg w próbce benzo(b)fluoranten (0,050 – 5,0) μg w próbce indeno","range":"(1,2,3-cd)piren"},{"name":"(0,050 – 5,0) μg w próbce benzo(ghi)perylen (0,050 – 5,0) μg w próbce Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nNaftalen (0,050 – 5,0) μg w próbce acenaften (0,050 – 5,0) μg w próbce fenantren (0,050 – 5,0) μg w próbce fluoranten (0,050 – 5,0) μg w próbce benzo(a)antracen\nZakres (0,050 – 5,0) μg w próbce\nbenzo(k)fluoranten (0,050 – 5,0) μg w próbce benzo(a)piren (0,050 – 5,0) μg w próbce dibenzo(a,h)antracen (0,050 – 5,0) μg w próbce fluoren (0,050 – 5,0) μg w próbce antracen (0,050 – 5,0) μg w próbce piren (0,050 – 5,0) μg w próbce chryzen (0,050 – 5,0) μg w próbce benzo(b)fluoranten (0,050 – 5,0) μg w próbce indeno (1,2,3-cd)piren\n(0,050 – 5,0) μg w próbce benzo(ghi)perylen (0,050 – 5,0) μg w próbce Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"ISO 11338-2:2003","norm_bases":["ISO 11338-2:2003"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne: - próbki gazów odlotowych pobrane na filtry, na rurki z sorbentem Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nNaftalen (0,050 – 5,0) μg w próbce acenaften (0,050 – 5,0) μg w próbce fenantren (0,050 – 5,0) μg w próbce fluoranten (0,050 – 5,0) μg w próbce benzo(a)antracen\nZakres (0,050 – 5,0) μg w próbce\nbenzo(k)fluoranten (0,050 – 5,0) μg w próbce benzo(a)piren (0,050 – 5,0) μg w próbce dibenzo(a,h)antracen (0,050 – 5,0) μg w próbce fluoren (0,050 – 5,0) μg w próbce antracen (0,050 – 5,0) μg w próbce piren (0,050 – 5,0) μg w próbce chryzen (0,050 – 5,0) μg w próbce benzo(b)fluoranten (0,050 – 5,0) μg w próbce indeno (1,2,3-cd)piren\n(0,050 – 5,0) μg w próbce benzo(ghi)perylen (0,050 – 5,0) μg w próbce Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) ISO 11338-2:2003 Srodowisko ogolne: - probki gazow odlotowych pobrane na filtry, na rurki z sorbentem Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nNaftalen (0,050 – 5,0) μg w probce acenaften (0,050 – 5,0) μg w probce fenantren (0,050 – 5,0) μg w probce fluoranten (0,050 – 5,0) μg w probce benzo(a)antracen\nZakres (0,050 – 5,0) μg w probce\nbenzo(k)fluoranten (0,050 – 5,0) μg w probce benzo(a)piren (0,050 – 5,0) μg w probce dibenzo(a,h)antracen (0,050 – 5,0) μg w probce fluoren (0,050 – 5,0) μg w probce antracen (0,050 – 5,0) μg w probce piren (0,050 – 5,0) μg w probce chryzen (0,050 – 5,0) μg w probce benzo(b)fluoranten (0,050 – 5,0) μg w probce indeno (1,2,3-cd)piren\n(0,050 – 5,0) μg w probce benzo(ghi)perylen (0,050 – 5,0) μg w probce Suma wielopierscieniowych weglowodorow aromatycznych (WWA) (z obliczen)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) ISO 11338-2:2003","categories":["environment"],"row_index":362,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polycyclic aromatic hydrocarbons (PAH) content","parameters_en":[{"name":"Naphthalene (0,050 – 5,0) μg in sample acenaphthene (0,050 – 5,0) μg in sample phenanthrene (0,050 – 5,0) μg in sample fluoranthene (0,050 – 5,0) μg in sample benzo(a)anthracene"},{"name":"Range","range":"(0,050 – 5,0) μg w próbce"},{"name":"benzo(k)fluoranthene (0,050 – 5,0) μg in the sample benzo(a)pyrene (0,050 – 5,0) μg in the sample dibenzo(a,h)anthracene (0,050 – 5,0) μg in the sample fluorene (0,050 – 5,0) μg in the sample anthracene (0,050 – 5,0) μg in the sample pyrene (0,050 – 5,0) μg in the sample chrysene (0,050 – 5,0) μg in the sample benzo(b)fluoranthene (0,050 – 5,0) μg in the sample indeno","range":"(1,2,3-cd)piren"},{"name":"(0,050 – 5,0) μg in the sample benzo(ghi)perylene (0,050 – 5,0) μg in the sample Sum of polycyclic aromatic hydrocarbons (PAH) (calculated)"}],"search_en":"Polycyclic aromatic hydrocarbons (PAH) content High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Naphthalene (0,050 – 5,0) μg in sample acenaphthene (0,050 – 5,0) μg in sample phenanthrene (0,050 – 5,0) μg in sample fluoranthene (0,050 – 5,0) μg in sample benzo(a)anthracene Range benzo(k)fluoranthene (0,050 – 5,0) μg in the sample benzo(a)pyrene (0,050 – 5,0) μg in the sample dibenzo(a,h)anthracene (0,050 – 5,0) μg in the sample fluorene (0,050 – 5,0) μg in the sample anthracene (0,050 – 5,0) μg in the sample pyrene (0,050 – 5,0) μg in the sample chrysene (0,050 – 5,0) μg in the sample benzo(b)fluoranthene (0,050 – 5,0) μg in the sample indeno (0,050 – 5,0) μg in the sample benzo(ghi)perylene (0,050 – 5,0) μg in the sample Sum of polycyclic aromatic hydrocarbons (PAH) (calculated) ISO 11338-2:2003","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","parameters_zh":[{"name":"Naftalen (0,050 – 5,0) μg w próbce acenaften (0,050 – 5,0) μg w próbce fenantren (0,050 – 5,0) μg w próbce fluoranten (0,050 – 5,0) μg w próbce benzo(a)antracen"},{"name":"范围","range":"(0,050 – 5,0) μg w próbce"},{"name":"benzo(k)fluoranten (0,050 – 5,0) μg w próbce benzo(a)piren (0,050 – 5,0) μg w próbce dibenzo(a,h)antracen (0,050 – 5,0) μg w próbce fluoren (0,050 – 5,0) μg w próbce antracen (0,050 – 5,0) μg w próbce piren (0,050 – 5,0) μg w próbce chryzen (0,050 – 5,0) μg w próbce benzo(b)fluoranten (0,050 – 5,0) μg w próbce indeno","range":"(1,2,3-cd)piren"},{"name":"(0,050 – 5,0) μg w próbce benzo(ghi)perylen (0,050 – 5,0) μg w próbce Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)"}],"search_zh":"多环芳烃（PAHs）含量 高效液相色谱-荧光检测法（HPLC-FLD） 范围 ISO 11338-2:2003","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","methodology_zh":"多环芳烃（PAHs）含量"},{"_id":"6a832b7f884ede9a1b2c5633","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady 1 kod E: 01 01, 01 04, 01 04, 01 01, 01 03, 02 01, 02 02, 02 03, 02 04, 02 05, 02 06, 02 07 03 01, 03 03 04 02 05 01, 05 07 06 02, 06 04, 06 05, 06 06, 06 09 07 01, 07 02, 07 03, 07 04, 07 05 07 06, 07 07 08 01, 09 01 10 01, 10 02, 10 03, 10 04, 10 05 10 06 , 10 08, 10 09, 10 11, 10 12 11 01 12 01 13 05 15 01, 15 02 16 01, 16 02, 16 07, 16 08, 16 11 17 01,17 02, 17 03, 17 05, 17 06 17 09 19 01, 19 02, 19 03, 19 05, 19 08 19 10 , 19 11, 19 12, 19 13 20 01, 20 02, 20 03; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(0,10 – 1000) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość formaldehydu\nZakres (0,10 – 1000) mg/kg\nMetoda spektrofotometryczna","reference":"Normy Procedury","norm_bases":["Normy Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady 1 kod E: 01 01, 01 04, 01 04, 01 01, 01 03, 02 01, 02 02, 02 03, 02 04, 02 05, 02 06, 02 07 03 01, 03 03 04 02 05 01, 05 07 06 02, 06 04, 06 05, 06 06, 06 09 07 01, 07 02, 07 03, 07 04, 07 05 07 06, 07 07 08 01, 09 01 10 01, 10 02, 10 03, 10 04, 10 05 10 06 , 10 08, 10 09, 10 11, 10 12 11 01 12 01 13 05 15 01, 15 02 16 01, 16 02, 16 07, 16 08, 16 11 17 01,17 02, 17 03, 17 05, 17 06 17 09 19 01, 19 02, 19 03, 19 05, 19 08 19 10 , 19 11, 19 12, 19 13 20 01, 20 02, 20 03; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość formaldehydu\nZakres (0,10 – 1000) mg/kg\nMetoda spektrofotometryczna Normy Procedury Odpady 1 kod E: 01 01, 01 04, 01 04, 01 01, 01 03, 02 01, 02 02, 02 03, 02 04, 02 05, 02 06, 02 07 03 01, 03 03 04 02 05 01, 05 07 06 02, 06 04, 06 05, 06 06, 06 09 07 01, 07 02, 07 03, 07 04, 07 05 07 06, 07 07 08 01, 09 01 10 01, 10 02, 10 03, 10 04, 10 05 10 06 , 10 08, 10 09, 10 11, 10 12 11 01 12 01 13 05 15 01, 15 02 16 01, 16 02, 16 07, 16 08, 16 11 17 01,17 02, 17 03, 17 05, 17 06 17 09 19 01, 19 02, 19 03, 19 05, 19 08 19 10 , 19 11, 19 12, 19 13 20 01, 20 02, 20 03; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc formaldehydu\nZakres (0,10 – 1000) mg/kg\nMetoda spektrofotometryczna Normy Procedury","categories":["environment"],"row_index":363,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde content","parameters_en":[{"name":"Range","range":"(0,10 – 1000) mg/kg"}],"search_en":"Formaldehyde content Spectrophotometric method Range Normy Procedury","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(0,10 – 1000) mg/kg"}],"search_zh":"甲醛含量 分光光度法 范围 Normy Procedury","technique_zh":"分光光度法","methodology_zh":"甲醛含量"},{"_id":"6a832b7f884ede9a1b2c5634","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady 1 kod E: 01 01, 01 04, 01 04, 01 01, 01 03, 02 01, 02 02, 02 03, 02 04, 02 05, 02 06, 02 07 03 01, 03 03 04 02 05 01, 05 07 06 02, 06 04, 06 05, 06 06, 06 09 07 01, 07 02, 07 03, 07 04, 07 05 07 06, 07 07 08 01, 09 01 10 01, 10 02, 10 03, 10 04, 10 05 10 06 , 10 08, 10 09, 10 11, 10 12 11 01 12 01 13 05 15 01, 15 02 16 01, 16 02, 16 07, 16 08, 16 11 17 01,17 02, 17 03, 17 05, 17 06 17 09 19 01, 19 02, 19 03, 19 05, 19 08 19 10 , 19 11, 19 12, 19 13 20 01, 20 02, 20 03; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość siarczków","parameters":[{"name":"Zakres","range":"(1,0 – 200) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość siarczków\nZakres (1,0 – 200) mg/kg\nMetoda spektrofotometryczna","reference":"Normy Procedury","norm_bases":["Normy Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady 1 kod E: 01 01, 01 04, 01 04, 01 01, 01 03, 02 01, 02 02, 02 03, 02 04, 02 05, 02 06, 02 07 03 01, 03 03 04 02 05 01, 05 07 06 02, 06 04, 06 05, 06 06, 06 09 07 01, 07 02, 07 03, 07 04, 07 05 07 06, 07 07 08 01, 09 01 10 01, 10 02, 10 03, 10 04, 10 05 10 06 , 10 08, 10 09, 10 11, 10 12 11 01 12 01 13 05 15 01, 15 02 16 01, 16 02, 16 07, 16 08, 16 11 17 01,17 02, 17 03, 17 05, 17 06 17 09 19 01, 19 02, 19 03, 19 05, 19 08 19 10 , 19 11, 19 12, 19 13 20 01, 20 02, 20 03; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość siarczków\nZakres (1,0 – 200) mg/kg\nMetoda spektrofotometryczna Normy Procedury Odpady 1 kod E: 01 01, 01 04, 01 04, 01 01, 01 03, 02 01, 02 02, 02 03, 02 04, 02 05, 02 06, 02 07 03 01, 03 03 04 02 05 01, 05 07 06 02, 06 04, 06 05, 06 06, 06 09 07 01, 07 02, 07 03, 07 04, 07 05 07 06, 07 07 08 01, 09 01 10 01, 10 02, 10 03, 10 04, 10 05 10 06 , 10 08, 10 09, 10 11, 10 12 11 01 12 01 13 05 15 01, 15 02 16 01, 16 02, 16 07, 16 08, 16 11 17 01,17 02, 17 03, 17 05, 17 06 17 09 19 01, 19 02, 19 03, 19 05, 19 08 19 10 , 19 11, 19 12, 19 13 20 01, 20 02, 20 03; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc siarczkow\nZakres (1,0 – 200) mg/kg\nMetoda spektrofotometryczna Normy Procedury","categories":["environment"],"row_index":364,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfide content","parameters_en":[{"name":"Range","range":"(1,0 – 200) mg/kg"}],"search_en":"Sulfide content Spectrophotometric method Range Normy Procedury","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(1,0 – 200) mg/kg"}],"search_zh":"硫化物含量 分光光度法 范围 Normy Procedury","technique_zh":"分光光度法","methodology_zh":"硫化物含量"},{"_id":"6a832b7f884ede9a1b2c5635","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady 1 kod E: 01 01, 01 04, 01 04, 01 01, 01 03, 02 01, 02 02, 02 03, 02 04, 02 05, 02 06, 02 07 03 01, 03 03 04 02 05 01, 05 07 06 02, 06 04, 06 05, 06 06, 06 09 07 01, 07 02, 07 03, 07 04, 07 05 07 06, 07 07 08 01, 09 01 10 01, 10 02, 10 03, 10 04, 10 05 10 06 , 10 08, 10 09, 10 11, 10 12 11 01 12 01 13 05 15 01, 15 02 16 01, 16 02, 16 07, 16 08, 16 11 17 01,17 02, 17 03, 17 05, 17 06 17 09 19 01, 19 02, 19 03, 19 05, 19 08 19 10 , 19 11, 19 12, 19 13 20 01, 20 02, 20 03; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość siarczynów","parameters":[{"name":"Zakres","range":"(1,0 – 500) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość siarczynów\nZakres (1,0 – 500) mg/kg\nMetoda spektrofotometryczna","reference":"Normy Procedury","norm_bases":["Normy Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady 1 kod E: 01 01, 01 04, 01 04, 01 01, 01 03, 02 01, 02 02, 02 03, 02 04, 02 05, 02 06, 02 07 03 01, 03 03 04 02 05 01, 05 07 06 02, 06 04, 06 05, 06 06, 06 09 07 01, 07 02, 07 03, 07 04, 07 05 07 06, 07 07 08 01, 09 01 10 01, 10 02, 10 03, 10 04, 10 05 10 06 , 10 08, 10 09, 10 11, 10 12 11 01 12 01 13 05 15 01, 15 02 16 01, 16 02, 16 07, 16 08, 16 11 17 01,17 02, 17 03, 17 05, 17 06 17 09 19 01, 19 02, 19 03, 19 05, 19 08 19 10 , 19 11, 19 12, 19 13 20 01, 20 02, 20 03; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość siarczynów\nZakres (1,0 – 500) mg/kg\nMetoda spektrofotometryczna Normy Procedury Odpady 1 kod E: 01 01, 01 04, 01 04, 01 01, 01 03, 02 01, 02 02, 02 03, 02 04, 02 05, 02 06, 02 07 03 01, 03 03 04 02 05 01, 05 07 06 02, 06 04, 06 05, 06 06, 06 09 07 01, 07 02, 07 03, 07 04, 07 05 07 06, 07 07 08 01, 09 01 10 01, 10 02, 10 03, 10 04, 10 05 10 06 , 10 08, 10 09, 10 11, 10 12 11 01 12 01 13 05 15 01, 15 02 16 01, 16 02, 16 07, 16 08, 16 11 17 01,17 02, 17 03, 17 05, 17 06 17 09 19 01, 19 02, 19 03, 19 05, 19 08 19 10 , 19 11, 19 12, 19 13 20 01, 20 02, 20 03; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc siarczynow\nZakres (1,0 – 500) mg/kg\nMetoda spektrofotometryczna Normy Procedury","categories":["environment"],"row_index":365,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfite content","parameters_en":[{"name":"Range","range":"(1,0 – 500) mg/kg"}],"search_en":"Sulfite content Spectrophotometric method Range Normy Procedury","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(1,0 – 500) mg/kg"}],"search_zh":"亚硫酸盐含量 分光光度法 范围 Normy Procedury","technique_zh":"分光光度法","methodology_zh":"亚硫酸盐含量"},{"_id":"6a832b7f884ede9a1b2c5636","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady 1 kod E: 01 01, 01 04, 01 04, 01 01, 01 03, 02 01, 02 02, 02 03, 02 04, 02 05, 02 06, 02 07 03 01, 03 03 04 02 05 01, 05 07 06 02, 06 04, 06 05, 06 06, 06 09 07 01, 07 02, 07 03, 07 04, 07 05 07 06, 07 07 08 01, 09 01 10 01, 10 02, 10 03, 10 04, 10 05 10 06 , 10 08, 10 09, 10 11, 10 12 11 01 12 01 13 05 15 01, 15 02 16 01, 16 02, 16 07, 16 08, 16 11 17 01,17 02, 17 03, 17 05, 17 06 17 09 19 01, 19 02, 19 03, 19 05, 19 08 19 10 , 19 11, 19 12, 19 13 20 01, 20 02, 20 03; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość siarkowodoru i siarczków","parameters":[{"name":"Zakres","range":"(2,0 – 100) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość siarkowodoru i siarczków\nZakres (2,0 – 100) mg/kg\nMetoda miareczkowa","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady 1 kod E: 01 01, 01 04, 01 04, 01 01, 01 03, 02 01, 02 02, 02 03, 02 04, 02 05, 02 06, 02 07 03 01, 03 03 04 02 05 01, 05 07 06 02, 06 04, 06 05, 06 06, 06 09 07 01, 07 02, 07 03, 07 04, 07 05 07 06, 07 07 08 01, 09 01 10 01, 10 02, 10 03, 10 04, 10 05 10 06 , 10 08, 10 09, 10 11, 10 12 11 01 12 01 13 05 15 01, 15 02 16 01, 16 02, 16 07, 16 08, 16 11 17 01,17 02, 17 03, 17 05, 17 06 17 09 19 01, 19 02, 19 03, 19 05, 19 08 19 10 , 19 11, 19 12, 19 13 20 01, 20 02, 20 03; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość siarkowodoru i siarczków\nZakres (2,0 – 100) mg/kg\nMetoda miareczkowa Normy Odpady 1 kod E: 01 01, 01 04, 01 04, 01 01, 01 03, 02 01, 02 02, 02 03, 02 04, 02 05, 02 06, 02 07 03 01, 03 03 04 02 05 01, 05 07 06 02, 06 04, 06 05, 06 06, 06 09 07 01, 07 02, 07 03, 07 04, 07 05 07 06, 07 07 08 01, 09 01 10 01, 10 02, 10 03, 10 04, 10 05 10 06 , 10 08, 10 09, 10 11, 10 12 11 01 12 01 13 05 15 01, 15 02 16 01, 16 02, 16 07, 16 08, 16 11 17 01,17 02, 17 03, 17 05, 17 06 17 09 19 01, 19 02, 19 03, 19 05, 19 08 19 10 , 19 11, 19 12, 19 13 20 01, 20 02, 20 03; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc siarkowodoru i siarczkow\nZakres (2,0 – 100) mg/kg\nMetoda miareczkowa Normy","categories":["environment"],"row_index":366,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of hydrogen sulphide and sulphides","parameters_en":[{"name":"Range","range":"(2,0 – 100) mg/kg"}],"search_en":"Content of hydrogen sulphide and sulphides Titrimetric method Range Normy","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(2,0 – 100) mg/kg"}],"search_zh":"滴定法 范围 Normy","technique_zh":"滴定法"},{"_id":"6a832b7f884ede9a1b2c5637","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11 : - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","methodology":"Stężenie anionów 1, 3, 5","parameters":[{"name":"Siarczany","range":"(0,5 – 20000) mg/l"},{"name":"Chlorki","range":"(2,0 – 20000) mg/l"},{"name":"Fluorki","range":"(0,05 – 5,0) mg/l"},{"name":"Zawartość anionów z obliczeń"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie anionów 1, 3, 5\nZakres:\nSiarczany (0,5 – 20000) mg/l\nChlorki (2,0 – 20000) mg/l\nFluorki (0,05 – 5,0) mg/l\nZawartość anionów z obliczeń\nMetoda spektrofotometryczna","reference":"P N -EN 12457-4:2006 EFO/PB/28/A: 24.05.2024","norm_bases":["P N -EN 12457-4:2006 EFO/PB/28/A: 24.05.2024"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11 : - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. Stężenie anionów 1, 3, 5\nZakres:\nSiarczany (0,5 – 20000) mg/l\nChlorki (2,0 – 20000) mg/l\nFluorki (0,05 – 5,0) mg/l\nZawartość anionów z obliczeń\nMetoda spektrofotometryczna P N -EN 12457-4:2006 EFO/PB/28/A: 24.05.2024 Odpady DAB-11 : - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V), Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11. Stezenie anionow 1, 3, 5\nZakres:\nSiarczany (0,5 – 20000) mg/l\nChlorki (2,0 – 20000) mg/l\nFluorki (0,05 – 5,0) mg/l\nZawartosc anionow z obliczen\nMetoda spektrofotometryczna P N -EN 12457-4:2006 EFO/PB/28/A: 24.05.2024","categories":["water","environment","food","materials","construction"],"row_index":367,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations 1, 3, 5","parameters_en":[{"name":"Sulfates","range":"(0,5 – 20000) mg/l"},{"name":"Chlorides","range":"(2,0 – 20000) mg/l"},{"name":"Fluorides","range":"(0,05 – 5,0) mg/l"},{"name":"Anion content calculated"}],"search_en":"Anion concentrations 1, 3, 5 Spectrophotometric method Sulfates Chlorides Fluorides Anion content calculated P N -EN 12457-4:2006 EFO/PB/28/A: 24.05.2024","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"硫酸盐","range":"(0,5 – 20000) mg/l"},{"name":"氯化物","range":"(2,0 – 20000) mg/l"},{"name":"氟化物","range":"(0,05 – 5,0) mg/l"},{"name":"Zawartość anionów z obliczeń"}],"search_zh":"分光光度法 硫酸盐 氯化物 氟化物 P N -EN 12457-4:2006 EFO/PB/28/A: 24.05.2024","technique_zh":"分光光度法"},{"_id":"6a832b7f884ede9a1b2c5638","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) - Żużle, popioły i pyły paleniskowe (XI); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","methodology":"Zawartość tlenu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość tlenu (z obliczeń)","reference":"EFO/PB/30/A: 24.05.2024","norm_bases":["EFO/PB/30/A: 24.05.2024"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) - Żużle, popioły i pyły paleniskowe (XI); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. Zawartość tlenu (z obliczeń) EFO/PB/30/A: 24.05.2024 Odpady DAB-11: - Odpady z przetwarzania odpadow (VI) - Zuzle, popioly i pyly paleniskowe (XI); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11. Zawartosc tlenu (z obliczen) EFO/PB/30/A: 24.05.2024","categories":["environment"],"row_index":368,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxygen content (calculated)","search_en":"Oxygen content (calculated) EFO/PB/30/A: 24.05.2024","methodology_zh":"氧含量（由计算得出）","search_zh":"氧含量（由计算得出） EFO/PB/30/A: 24.05.2024"},{"_id":"6a832b7f884ede9a1b2c5639","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11 : - Osady i odpady mineralne (I) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Drewno (XXVI) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady0) kod: 17 01 82, 17 05 07, 19 08 99; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów; DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","methodology":"pH 1, 4, 5","parameters":[{"name":"Zakres","range":"2,0 – 13,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH 1, 4, 5\nZakres 2,0 – 13,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11 : - Osady i odpady mineralne (I) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Drewno (XXVI) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII), Odpady0) kod: 17 01 82, 17 05 07, 19 08 99; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów; DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. pH 1, 4, 5\nZakres 2,0 – 13,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Odpady DAB-11 : - Osady i odpady mineralne (I) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V), Odpady z przetwarzania odpadow (VI) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Drewno (XXVI) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII), Odpady0) kod: 17 01 82, 17 05 07, 19 08 99; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow; DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11. pH 1, 4, 5\nZakres 2,0 – 13,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water","environment","food"],"row_index":369,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH 1, 4, 5","parameters_en":[{"name":"Range","range":"2,0 – 13,0"}],"search_en":"pH 1, 4, 5 Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","parameters_zh":[{"name":"范围","range":"2,0 – 13,0"}],"search_zh":"电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法"},{"_id":"6a832b7f884ede9a1b2c563a","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA) 1, 3, 5 naftalen (0,025 – 100) mg/kg antracen (0,025 – 100) mg/kg chryzen (0,025 – 100) mg/kg benzo(a)antracen (0,025 – 100) mg/kg dibenzo(a,h)antracen (0,025 – 100) mg/kg benzo(a)piren (0,025 – 100) mg/kg benzo(b)fluoranten (0,025 – 100) mg/kg benzo(k)fluoranten 0,025 – 100) mg/kg benzo(ghi)perylen (0,025 – 100) mg/kg indeno(1,2,3-cd)piren (0,025 – 100) mg/kg acenaften (0,025 – 100) mg/kg acenaftylen (0,025 – 100) mg/kg fluoranten (0,025 – 100) mg/kg fluoren (0,025 – 100) mg/kg fenantren (0,025 – 100) mg/kg piren (0,025 – 100) mg/kg","parameters":[{"name":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA) 1, 3, 5 naftalen (0,025 – 100) mg/kg antracen (0,025 – 100) mg/kg chryzen (0,025 – 100) mg/kg benzo(a)antracen (0,025 – 100) mg/kg dibenzo(a,h)antracen (0,025 – 100) mg/kg benzo(a)piren (0,025 – 100) mg/kg benzo(b)fluoranten (0,025 – 100) mg/kg benzo(k)fluoranten 0,025 – 100) mg/kg benzo(ghi)perylen (0,025 – 100) mg/kg indeno(1,2,3-cd)piren (0,025 – 100) mg/kg acenaften (0,025 – 100) mg/kg acenaftylen (0,025 – 100) mg/kg fluoranten (0,025 – 100) mg/kg fluoren (0,025 – 100) mg/kg fenantren (0,025 – 100) mg/kg piren (0,025 – 100) mg/kg\nSuma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"EFO/PB/44/B:05.09.2025","norm_bases":["EFO/PB/44/B:05.09.2025"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA) 1, 3, 5 naftalen (0,025 – 100) mg/kg antracen (0,025 – 100) mg/kg chryzen (0,025 – 100) mg/kg benzo(a)antracen (0,025 – 100) mg/kg dibenzo(a,h)antracen (0,025 – 100) mg/kg benzo(a)piren (0,025 – 100) mg/kg benzo(b)fluoranten (0,025 – 100) mg/kg benzo(k)fluoranten 0,025 – 100) mg/kg benzo(ghi)perylen (0,025 – 100) mg/kg indeno(1,2,3-cd)piren (0,025 – 100) mg/kg acenaften (0,025 – 100) mg/kg acenaftylen (0,025 – 100) mg/kg fluoranten (0,025 – 100) mg/kg fluoren (0,025 – 100) mg/kg fenantren (0,025 – 100) mg/kg piren (0,025 – 100) mg/kg\nSuma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) EFO/PB/44/B:05.09.2025 Odpady DAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11. Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA) 1, 3, 5 naftalen (0,025 – 100) mg/kg antracen (0,025 – 100) mg/kg chryzen (0,025 – 100) mg/kg benzo(a)antracen (0,025 – 100) mg/kg dibenzo(a,h)antracen (0,025 – 100) mg/kg benzo(a)piren (0,025 – 100) mg/kg benzo(b)fluoranten (0,025 – 100) mg/kg benzo(k)fluoranten 0,025 – 100) mg/kg benzo(ghi)perylen (0,025 – 100) mg/kg indeno(1,2,3-cd)piren (0,025 – 100) mg/kg acenaften (0,025 – 100) mg/kg acenaftylen (0,025 – 100) mg/kg fluoranten (0,025 – 100) mg/kg fluoren (0,025 – 100) mg/kg fenantren (0,025 – 100) mg/kg piren (0,025 – 100) mg/kg\nSuma wielopierscieniowych weglowodorow aromatycznych (WWA) (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) EFO/PB/44/B:05.09.2025","categories":["water","environment","food","materials","construction"],"row_index":370,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Sum of polycyclic aromatic hydrocarbons (PAH) (calculated)"}],"search_en":"Gas chromatography with mass spectrometry detection (GC-MS) Sum of polycyclic aromatic hydrocarbons (PAH) (calculated) EFO/PB/44/B:05.09.2025","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","search_zh":"气相色谱-质谱法（GC-MS） 多环芳烃（PAH）总量（由计算得出） EFO/PB/44/B:05.09.2025","technique_zh":"气相色谱-质谱法（GC-MS）","parameters_zh":[{"name":"多环芳烃（PAH）总量（由计算得出）"}]},{"_id":"6a832b7f884ede9a1b2c563b","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","methodology":"Zawartość polichlorowanych bifenyli (PCB) 1, 3, 5","parameters":[{"name":"PCB 28","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 52","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 101","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 118","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 138","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 153","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 180","range":"(0,020 – 2,5) mg/kg"},{"name":"Suma polichlorowanych bifenyli (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość polichlorowanych bifenyli (PCB) 1, 3, 5\nZakres:\nPCB 28 (0,020 – 2,5) mg/kg\nPCB 52 (0,020 – 2,5) mg/kg\nPCB 101 (0,020 – 2,5) mg/kg\nPCB 118 (0,020 – 2,5) mg/kg\nPCB 138 (0,020 – 2,5) mg/kg\nPCB 153 (0,020 – 2,5) mg/kg\nPCB 180 (0,020 – 2,5) mg/kg\nSuma polichlorowanych bifenyli (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"EFO/PB/43/B:05.09.2025","norm_bases":["EFO/PB/43/B:05.09.2025"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. Zawartość polichlorowanych bifenyli (PCB) 1, 3, 5\nZakres:\nPCB 28 (0,020 – 2,5) mg/kg\nPCB 52 (0,020 – 2,5) mg/kg\nPCB 101 (0,020 – 2,5) mg/kg\nPCB 118 (0,020 – 2,5) mg/kg\nPCB 138 (0,020 – 2,5) mg/kg\nPCB 153 (0,020 – 2,5) mg/kg\nPCB 180 (0,020 – 2,5) mg/kg\nSuma polichlorowanych bifenyli (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) EFO/PB/43/B:05.09.2025 Odpady DAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11. Zawartosc polichlorowanych bifenyli (PCB) 1, 3, 5\nZakres:\nPCB 28 (0,020 – 2,5) mg/kg\nPCB 52 (0,020 – 2,5) mg/kg\nPCB 101 (0,020 – 2,5) mg/kg\nPCB 118 (0,020 – 2,5) mg/kg\nPCB 138 (0,020 – 2,5) mg/kg\nPCB 153 (0,020 – 2,5) mg/kg\nPCB 180 (0,020 – 2,5) mg/kg\nSuma polichlorowanych bifenyli (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) EFO/PB/43/B:05.09.2025","categories":["water","environment","food","materials","construction"],"row_index":371,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polychlorinated biphenyl (PCB) content 1, 3, 5","parameters_en":[{"name":"PCB 28","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 52","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 101","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 118","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 138","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 153","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 180","range":"(0,020 – 2,5) mg/kg"},{"name":"Sum of polychlorinated biphenyls (calculated)"}],"search_en":"Polychlorinated biphenyl (PCB) content 1, 3, 5 Gas chromatography with mass spectrometry detection (GC-MS) PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 Sum of polychlorinated biphenyls (calculated) EFO/PB/43/B:05.09.2025","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","search_zh":"气相色谱-质谱法（GC-MS） PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 多氯联苯总量（由计算得出） EFO/PB/43/B:05.09.2025","technique_zh":"气相色谱-质谱法（GC-MS）","parameters_zh":[{"name":"PCB 28","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 52","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 101","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 118","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 138","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 153","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 180","range":"(0,020 – 2,5) mg/kg"},{"name":"多氯联苯总量（由计算得出）"}]},{"_id":"6a832b7f884ede9a1b2c563c","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZT-Cr 7"},{"name":"Zakres","range":"(50 – 100000) mg/kg O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr 7\nZakres (50 – 100000) mg/kg O2\nMetoda spektrofotometryczna","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr 7\nZakres (50 – 100000) mg/kg O2\nMetoda spektrofotometryczna Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V), Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr 7\nZakres (50 – 100000) mg/kg O2\nMetoda spektrofotometryczna Normy","categories":["water","environment","food","materials","construction"],"row_index":372,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"COD-Cr 7"},{"name":"Range","range":"(50 – 100000) mg/kg O2"}],"search_en":"Chemical oxygen demand Spectrophotometric method COD-Cr 7 Range Normy","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"ChZT-Cr 7"},{"name":"范围","range":"(50 – 100000) mg/kg O2"}],"search_zh":"化学需氧量（COD） 分光光度法 范围 Normy","technique_zh":"分光光度法","methodology_zh":"化学需氧量（COD）"},{"_id":"6a832b7f884ede9a1b2c563d","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"pH 1, 3, 5","parameters":[{"name":"Zakres","range":"2,0 – 13,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH 1, 3, 5\nZakres 2,0 – 13,0\nMetoda potencjometryczna","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. pH 1, 3, 5\nZakres 2,0 – 13,0\nMetoda potencjometryczna Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V), Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. pH 1, 3, 5\nZakres 2,0 – 13,0\nMetoda potencjometryczna Normy","categories":["water","environment","food","materials","construction"],"row_index":373,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH 1, 3, 5","parameters_en":[{"name":"Range","range":"2,0 – 13,0"}],"search_en":"pH 1, 3, 5 Potentiometric method Range Normy","technique_en":"Potentiometric method","parameters_zh":[{"name":"范围","range":"2,0 – 13,0"}],"search_zh":"电位法 范围 Normy","technique_zh":"电位法"},{"_id":"6a832b7f884ede9a1b2c563e","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Stałe związki rozpuszczone / TDS 1, 3, 5","parameters":[{"name":"Zakres","range":"(100 – 600000) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stałe związki rozpuszczone / TDS 1, 3, 5\nZakres (100 – 600000) mg/kg\nMetoda wagowa","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Stałe związki rozpuszczone / TDS 1, 3, 5\nZakres (100 – 600000) mg/kg\nMetoda wagowa Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V), Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Stale zwiazki rozpuszczone / TDS 1, 3, 5\nZakres (100 – 600000) mg/kg\nMetoda wagowa Normy","categories":["water","environment","food","materials","construction"],"row_index":374,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids / TDS 1, 3, 5","parameters_en":[{"name":"Range","range":"(100 – 600000) mg/kg"}],"search_en":"Total dissolved solids / TDS 1, 3, 5 Gravimetric method Range Normy","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(100 – 600000) mg/kg"}],"search_zh":"重量法 范围 Normy","technique_zh":"重量法"},{"_id":"6a832b7f884ede9a1b2c563f","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zasadowość ogólna (zdolność do neutralizacji kwasów ANC) 1","parameters":[{"name":"Zakres","range":"(50 – 50000) mg/kg CaCO3"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Zasadowość ogólna (zdolność do neutralizacji kwasów ANC) 1\nZakres (50 – 50000) mg/kg CaCO3\nMetoda miareczkowania potencjometrycznego","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zasadowość ogólna (zdolność do neutralizacji kwasów ANC) 1\nZakres (50 – 50000) mg/kg CaCO3\nMetoda miareczkowania potencjometrycznego Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V), Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zasadowosc ogolna (zdolnosc do neutralizacji kwasow ANC) 1\nZakres (50 – 50000) mg/kg CaCO3\nMetoda miareczkowania potencjometrycznego Normy","categories":["water","environment","food","materials","construction"],"row_index":375,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total alkalinity (acid neutralising capacity ANC) 1","parameters_en":[{"name":"Range","range":"(50 – 50000) mg/kg CaCO3"}],"search_en":"Total alkalinity (acid neutralising capacity ANC) 1 Potentiometric titration method Range Normy","technique_en":"Potentiometric titration method","parameters_zh":[{"name":"范围","range":"(50 – 50000) mg/kg CaCO3"}],"search_zh":"电位滴定法 范围 Normy","technique_zh":"电位滴定法"},{"_id":"6a832b7f884ede9a1b2c5640","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość anionów","parameters":[{"name":"Siarczany","range":"(10 – 250000) mg/kg"},{"name":"Chlorki","range":"(10 – 250000) mg/kg"},{"name":"Fluorki","range":"(1,0 – 10000) mg/kg"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Zawartość anionów\nZakres:\nSiarczany (10 – 250000) mg/kg\nChlorki (10 – 250000) mg/kg\nFluorki (1,0 – 10000) mg/kg\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V), Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość anionów\nZakres:\nSiarczany (10 – 250000) mg/kg\nChlorki (10 – 250000) mg/kg\nFluorki (1,0 – 10000) mg/kg\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V), Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc anionow\nZakres:\nSiarczany (10 – 250000) mg/kg\nChlorki (10 – 250000) mg/kg\nFluorki (1,0 – 10000) mg/kg\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Normy","categories":["water","environment","food","materials","construction"],"row_index":376,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion content","parameters_en":[{"name":"Sulfates","range":"(10 – 250000) mg/kg"},{"name":"Chlorides","range":"(10 – 250000) mg/kg"},{"name":"Fluorides","range":"(1,0 – 10000) mg/kg"}],"search_en":"Anion content Ion chromatography with conductometric detection (IC-CD) Sulfates Chlorides Fluorides Normy","technique_en":"Ion chromatography with conductometric detection (IC-CD)","parameters_zh":[{"name":"硫酸盐","range":"(10 – 250000) mg/kg"},{"name":"氯化物","range":"(10 – 250000) mg/kg"},{"name":"氟化物","range":"(1,0 – 10000) mg/kg"}],"search_zh":"阴离子含量 离子色谱-电导检测法（IC-CD） 硫酸盐 氯化物 氟化物 Normy","technique_zh":"离子色谱-电导检测法（IC-CD）","methodology_zh":"阴离子含量"},{"_id":"6a832b7f884ede9a1b2c5641","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Indeks fenolowy 1, 3, 5","parameters":[{"name":"Zakres","range":"(0,050 – 500) mg/kg"},{"name":"CFA z detekcją spektrometryczną"}],"technique":"Metoda ciągłej analizy przepływowej","techniques":["Metoda ciągłej analizy przepływowej"],"computed":[],"activity":"Indeks fenolowy 1, 3, 5\nZakres:\nZakres (0,050 – 500) mg/kg\nCFA z detekcją spektrometryczną\nMetoda ciągłej analizy przepływowej","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Indeks fenolowy 1, 3, 5\nZakres:\nZakres (0,050 – 500) mg/kg\nCFA z detekcją spektrometryczną\nMetoda ciągłej analizy przepływowej Normy Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Indeks fenolowy 1, 3, 5\nZakres:\nZakres (0,050 – 500) mg/kg\nCFA z detekcja spektrometryczna\nMetoda ciaglej analizy przeplywowej Normy","categories":["water","environment","food","materials","construction"],"row_index":377,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index 1, 3, 5","parameters_en":[{"name":"Range","range":"(0,050 – 500) mg/kg"},{"name":"CFA z detekcją spektrometryczną"}],"search_en":"Phenol index 1, 3, 5 Continuous flow analysis method Range Normy","technique_en":"Continuous flow analysis method","parameters_zh":[{"name":"范围","range":"(0,050 – 500) mg/kg"},{"name":"CFA z detekcją spektrometryczną"}],"search_zh":"连续流动分析法 范围 Normy","technique_zh":"连续流动分析法"},{"_id":"6a832b7f884ede9a1b2c5642","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Przewodność elektryczna właściwa 1, 3, 5","parameters":[{"name":"Zakres","range":"(10 – 80000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa 1, 3, 5\nZakres (10 – 80000) μS/cm\nMetoda konduktometryczna","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Przewodność elektryczna właściwa 1, 3, 5\nZakres (10 – 80000) μS/cm\nMetoda konduktometryczna Normy Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Przewodnosc elektryczna wlasciwa 1, 3, 5\nZakres (10 – 80000) μS/cm\nMetoda konduktometryczna Normy","categories":["water","environment","food","materials","construction"],"row_index":378,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity 1, 3, 5","parameters_en":[{"name":"Range","range":"(10 – 80000) μS/cm"}],"search_en":"Electrical conductivity 1, 3, 5 Conductometric method Range Normy","technique_en":"Conductometric method","parameters_zh":[{"name":"范围","range":"(10 – 80000) μS/cm"}],"search_zh":"电导法 范围 Normy","technique_zh":"电导法"},{"_id":"6a832b7f884ede9a1b2c5643","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość azotu amonowego 2, 4","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość azotu amonowego 2, 4\nZakres (2,0 – 1000) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość azotu amonowego 2, 4\nZakres (2,0 – 1000) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Normy Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc azotu amonowego 2, 4\nZakres (2,0 – 1000) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna Normy","categories":["water","environment","food","materials","construction"],"row_index":379,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content 2, 4","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/kg"}],"search_en":"Ammonium nitrogen content 2, 4 Continuous flow analysis (CFA) with spectrophotometric detection Range Normy","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/kg"}],"search_zh":"连续流动分析（CFA）分光光度检测法 范围 Normy","technique_zh":"连续流动分析（CFA）分光光度检测法"},{"_id":"6a832b7f884ede9a1b2c5644","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość azotu Kjeldahla 2, 4","parameters":[{"name":"Zakres","range":"(5,0 – 20000) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla 2, 4\nZakres (5,0 – 20000) mg/kg\nMetoda miareczkowa","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość azotu Kjeldahla 2, 4\nZakres (5,0 – 20000) mg/kg\nMetoda miareczkowa Normy Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc azotu Kjeldahla 2, 4\nZakres (5,0 – 20000) mg/kg\nMetoda miareczkowa Normy","categories":["water","environment","food","materials","construction"],"row_index":380,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen content 2, 4","parameters_en":[{"name":"Range","range":"(5,0 – 20000) mg/kg"}],"search_en":"Kjeldahl nitrogen content 2, 4 Titrimetric method Range Normy","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(5,0 – 20000) mg/kg"}],"search_zh":"滴定法 范围 Normy","technique_zh":"滴定法"},{"_id":"6a832b7f884ede9a1b2c5645","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość azotu ogólnego 2, 4, Zawartość azotu organicznego 2, 4 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość azotu ogólnego 2, 4, Zawartość azotu organicznego 2, 4 (z obliczeń)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość azotu ogólnego 2, 4, Zawartość azotu organicznego 2, 4 (z obliczeń) Normy Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc azotu ogolnego 2, 4, Zawartosc azotu organicznego 2, 4 (z obliczen) Normy","categories":["water","environment","food","materials","construction"],"row_index":381,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a832b7f884ede9a1b2c5646","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość azotu azotynowego 2, 4","parameters":[{"name":"Zakres","range":"(0,20 – 25,0) mg/kg"},{"name":"Zawartość azotu azotanowego 2, 4"},{"name":"Zakres","range":"(2,0 – 1000) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość azotu azotynowego 2, 4\nZakres:\nZakres (0,20 – 25,0) mg/kg\nZawartość azotu azotanowego 2, 4\nZakres (2,0 – 1000) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość azotu azotynowego 2, 4\nZakres:\nZakres (0,20 – 25,0) mg/kg\nZawartość azotu azotanowego 2, 4\nZakres (2,0 – 1000) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Normy Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc azotu azotynowego 2, 4\nZakres:\nZakres (0,20 – 25,0) mg/kg\nZawartosc azotu azotanowego 2, 4\nZakres (2,0 – 1000) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna Normy","categories":["water","environment","food","materials","construction"],"row_index":382,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen content 2, 4","parameters_en":[{"name":"Range","range":"(0,20 – 25,0) mg/kg"},{"name":"Nitrate nitrogen content 2, 4"},{"name":"Range","range":"(2,0 – 1000) mg/kg"}],"search_en":"Nitrite nitrogen content 2, 4 Continuous flow analysis (CFA) with spectrophotometric detection Range Nitrate nitrogen content 2, 4 Range Normy","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","parameters_zh":[{"name":"范围","range":"(0,20 – 25,0) mg/kg"},{"name":"Zawartość azotu azotanowego 2, 4"},{"name":"范围","range":"(2,0 – 1000) mg/kg"}],"search_zh":"连续流动分析（CFA）分光光度检测法 范围 范围 Normy","technique_zh":"连续流动分析（CFA）分光光度检测法"},{"_id":"6a832b7f884ede9a1b2c5647","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość fosforanów","parameters":[{"name":"Zakres","range":"(0,50 – 2000) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforanów\nZakres (0,50 – 2000) mg/kg\nMetoda spektrofotometryczna","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość fosforanów\nZakres (0,50 – 2000) mg/kg\nMetoda spektrofotometryczna Normy Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc fosforanow\nZakres (0,50 – 2000) mg/kg\nMetoda spektrofotometryczna Normy","categories":["water","environment","food","materials","construction"],"row_index":383,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphate content","parameters_en":[{"name":"Range","range":"(0,50 – 2000) mg/kg"}],"search_en":"Phosphate content Spectrophotometric method Range Normy","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(0,50 – 2000) mg/kg"}],"search_zh":"分光光度法 范围 Normy","technique_zh":"分光光度法"},{"_id":"6a832b7f884ede9a1b2c5648","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Stężenie i zawartość cyjanków wolnych i ogólnych 7","parameters":[{"name":"Zakres","range":"(0,0050 – 10) mg/l"},{"name":"Zakres","range":"(0,050 – 100) mg/kg"},{"name":"Stężenie i zawartość cyjanków związanych (z obliczeń)"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie i zawartość cyjanków wolnych i ogólnych 7\nZakres:\nZakres (0,0050 – 10) mg/l\nZakres (0,050 – 100) mg/kg\nStężenie i zawartość cyjanków związanych (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Stężenie i zawartość cyjanków wolnych i ogólnych 7\nZakres:\nZakres (0,0050 – 10) mg/l\nZakres (0,050 – 100) mg/kg\nStężenie i zawartość cyjanków związanych (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Normy Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Stezenie i zawartosc cyjankow wolnych i ogolnych 7\nZakres:\nZakres (0,0050 – 10) mg/l\nZakres (0,050 – 100) mg/kg\nStezenie i zawartosc cyjankow zwiazanych (z obliczen)\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna Normy","categories":["water","environment","food","materials","construction"],"row_index":384,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free and total cyanide concentration and content 7","parameters_en":[{"name":"Range","range":"(0,0050 – 10) mg/l"},{"name":"Range","range":"(0,050 – 100) mg/kg"},{"name":"Concentration and content of bound cyanides (calculated)"}],"search_en":"Free and total cyanide concentration and content 7 Continuous flow analysis (CFA) with spectrophotometric detection Range Range Concentration and content of bound cyanides (calculated) Normy","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","parameters_zh":[{"name":"范围","range":"(0,0050 – 10) mg/l"},{"name":"范围","range":"(0,050 – 100) mg/kg"},{"name":"Stężenie i zawartość cyjanków związanych (z obliczeń)"}],"search_zh":"连续流动分析（CFA）分光光度检测法 范围 范围 Normy","technique_zh":"连续流动分析（CFA）分光光度检测法"},{"_id":"6a832b7f884ede9a1b2c5649","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość cyjanków wolnych i ogólnych","parameters":[{"name":"Zakres","range":"(0,50 – 100) mg/kg"},{"name":"Zawartość cyjanków związanych (z obliczeń)"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość cyjanków wolnych i ogólnych\nZakres:\nZakres (0,50 – 100) mg/kg\nZawartość cyjanków związanych (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość cyjanków wolnych i ogólnych\nZakres:\nZakres (0,50 – 100) mg/kg\nZawartość cyjanków związanych (z obliczeń)\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc cyjankow wolnych i ogolnych\nZakres:\nZakres (0,50 – 100) mg/kg\nZawartosc cyjankow zwiazanych (z obliczen)\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna Normy","categories":["water","environment","food","materials","construction"],"row_index":385,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free and total cyanide content","parameters_en":[{"name":"Range","range":"(0,50 – 100) mg/kg"},{"name":"Combined cyanide content (calculated)"}],"search_en":"Free and total cyanide content Continuous flow analysis (CFA) with spectrophotometric detection Range Combined cyanide content (calculated) Normy","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","parameters_zh":[{"name":"范围","range":"(0,50 – 100) mg/kg"},{"name":"络合氰化物含量（由计算得出）"}],"search_zh":"游离氰化物与总氰化物含量 连续流动分析（CFA）分光光度检测法 范围 络合氰化物含量（由计算得出） Normy","technique_zh":"连续流动分析（CFA）分光光度检测法","methodology_zh":"游离氰化物与总氰化物含量"},{"_id":"6a832b7f884ede9a1b2c564a","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Straty przy prażeniu (LOI) / substancje organiczne 1, 2, 3, 4, 5, 6, 7, 8","parameters":[{"name":"Zakres","range":"(0,1 – 99,5) %"}],"technique":"Metoda termograwimetryczna","techniques":["Metoda termograwimetryczna"],"computed":[],"activity":"Straty przy prażeniu (LOI) / substancje organiczne 1, 2, 3, 4, 5, 6, 7, 8\nZakres (0,1 – 99,5) %\nMetoda termograwimetryczna","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady z przetwarzania odpadów (VI) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Straty przy prażeniu (LOI) / substancje organiczne 1, 2, 3, 4, 5, 6, 7, 8\nZakres (0,1 – 99,5) %\nMetoda termograwimetryczna Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady z przetwarzania odpadow (VI) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Straty przy prazeniu (LOI) / substancje organiczne 1, 2, 3, 4, 5, 6, 7, 8\nZakres (0,1 – 99,5) %\nMetoda termograwimetryczna Normy","categories":["water","environment","construction"],"row_index":386,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition (LOI) / organic substances 1, 2, 3, 4, 5, 6, 7, 8","parameters_en":[{"name":"Range","range":"(0,1 – 99,5) %"}],"search_en":"Loss on ignition (LOI) / organic substances 1, 2, 3, 4, 5, 6, 7, 8 Thermogravimetric method Range Normy","technique_en":"Thermogravimetric method","parameters_zh":[{"name":"范围","range":"(0,1 – 99,5) %"}],"search_zh":"热重法 范围 Normy","technique_zh":"热重法"},{"_id":"6a832b7f884ede9a1b2c564b","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość ogólnego węgla organicznego (TOC) 1, 3, 5, 6, 7, 8","parameters":[{"name":"Zakres","range":"(0,10 – 60) %"},{"name":"Zakres","range":"(1000 – 600000) mg/kg"}],"technique":"Metoda wysoko temperaturowego spalania z detekcją IR","techniques":["Metoda wysoko temperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość ogólnego węgla organicznego (TOC) 1, 3, 5, 6, 7, 8\nZakres:\nZakres (0,10 – 60) %\nZakres (1000 – 600000) mg/kg\nMetoda wysoko temperaturowego spalania z detekcją IR","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość ogólnego węgla organicznego (TOC) 1, 3, 5, 6, 7, 8\nZakres:\nZakres (0,10 – 60) %\nZakres (1000 – 600000) mg/kg\nMetoda wysoko temperaturowego spalania z detekcją IR Normy Odpady DAB-11:E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc ogolnego wegla organicznego (TOC) 1, 3, 5, 6, 7, 8\nZakres:\nZakres (0,10 – 60) %\nZakres (1000 – 600000) mg/kg\nMetoda wysoko temperaturowego spalania z detekcja IR Normy","categories":["water","environment","materials","construction"],"row_index":387,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon (TOC) content 1, 3, 5, 6, 7, 8","parameters_en":[{"name":"Range","range":"(0,10 – 60) %"},{"name":"Range","range":"(1000 – 600000) mg/kg"}],"search_en":"Total organic carbon (TOC) content 1, 3, 5, 6, 7, 8 High-temperature combustion with IR detection Range Range Normy","technique_en":"High-temperature combustion with IR detection","parameters_zh":[{"name":"范围","range":"(0,10 – 60) %"},{"name":"范围","range":"(1000 – 600000) mg/kg"}],"search_zh":"高温燃烧-红外检测法 范围 范围 Normy","technique_zh":"高温燃烧-红外检测法"},{"_id":"6a832b7f884ede9a1b2c564c","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Straty przy prażeniu (LOI) / substancje organiczne 1, 2, 3, 4, 5, 6, 7, 8","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu (LOI) / substancje organiczne 1, 2, 3, 4, 5, 6, 7, 8\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Straty przy prażeniu (LOI) / substancje organiczne 1, 2, 3, 4, 5, 6, 7, 8\nZakres (0,5 – 99,5) %\nMetoda wagowa Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Straty przy prazeniu (LOI) / substancje organiczne 1, 2, 3, 4, 5, 6, 7, 8\nZakres (0,5 – 99,5) %\nMetoda wagowa Normy","categories":["water","environment","food","materials","construction"],"row_index":388,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition (LOI) / organic substances 1, 2, 3, 4, 5, 6, 7, 8","parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"search_en":"Loss on ignition (LOI) / organic substances 1, 2, 3, 4, 5, 6, 7, 8 Gravimetric method Range Normy","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"重量法 范围 Normy","technique_zh":"重量法"},{"_id":"6a832b7f884ede9a1b2c564d","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Straty przy prażeniu / zawartość popiołu 1, 2, 3, 4, 5, 6, 7, 8","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu / zawartość popiołu 1, 2, 3, 4, 5, 6, 7, 8\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Straty przy prażeniu / zawartość popiołu 1, 2, 3, 4, 5, 6, 7, 8\nZakres (0,5 – 99,5) %\nMetoda wagowa Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Straty przy prazeniu / zawartosc popiolu 1, 2, 3, 4, 5, 6, 7, 8\nZakres (0,5 – 99,5) %\nMetoda wagowa Normy","categories":["water","environment","food","materials","construction"],"row_index":389,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition / ash content 1, 2, 3, 4, 5, 6, 7, 8","parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"search_en":"Loss on ignition / ash content 1, 2, 3, 4, 5, 6, 7, 8 Gravimetric method Range Normy","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"重量法 范围 Normy","technique_zh":"重量法"},{"_id":"6a832b7f884ede9a1b2c564e","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,005 – 10,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (0,005 – 10,0) %\nMetoda miareczkowa","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość azotu amonowego\nZakres (0,005 – 10,0) %\nMetoda miareczkowa Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc azotu amonowego\nZakres (0,005 – 10,0) %\nMetoda miareczkowa Normy","categories":["water","environment","food","materials","construction"],"row_index":390,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,005 – 10,0) %"}],"search_en":"Ammonium nitrogen content Titrimetric method Range Normy","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(0,005 – 10,0) %"}],"search_zh":"氨氮含量 滴定法 范围 Normy","technique_zh":"滴定法","methodology_zh":"氨氮含量"},{"_id":"6a832b7f884ede9a1b2c564f","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość chlorków","parameters":[{"name":"Zakres","range":"(50 – 12000) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość chlorków\nZakres (50 – 12000) mg/kg\nMetoda miareczkowa","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość chlorków\nZakres (50 – 12000) mg/kg\nMetoda miareczkowa Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc chlorkow\nZakres (50 – 12000) mg/kg\nMetoda miareczkowa Normy","categories":["water","environment","food","materials","construction"],"row_index":391,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride content","parameters_en":[{"name":"Range","range":"(50 – 12000) mg/kg"}],"search_en":"Chloride content Titrimetric method Range Normy","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(50 – 12000) mg/kg"}],"search_zh":"氯化物含量 滴定法 范围 Normy","technique_zh":"滴定法","methodology_zh":"氯化物含量"},{"_id":"6a832b7f884ede9a1b2c5650","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość cyjanków wolnych, związanych, ogólnych","parameters":[{"name":"Zakres","range":"(0,125 – 500) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość cyjanków wolnych, związanych, ogólnych\nZakres (0,125 – 500) mg/kg\nMetoda spektrofotometryczna","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość cyjanków wolnych, związanych, ogólnych\nZakres (0,125 – 500) mg/kg\nMetoda spektrofotometryczna Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc cyjankow wolnych, zwiazanych, ogolnych\nZakres (0,125 – 500) mg/kg\nMetoda spektrofotometryczna Normy","categories":["water","environment","food","materials","construction"],"row_index":392,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free, bound and total cyanide content","parameters_en":[{"name":"Range","range":"(0,125 – 500) mg/kg"}],"search_en":"Free, bound and total cyanide content Spectrophotometric method Range Normy","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(0,125 – 500) mg/kg"}],"search_zh":"分光光度法 范围 Normy","technique_zh":"分光光度法"},{"_id":"6a832b7f884ede9a1b2c5651","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość fenoli","parameters":[{"name":"Zakres","range":"(0,05 – 500) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fenoli\nZakres (0,05 – 500) mg/kg\nMetoda spektrofotometryczna","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość fenoli\nZakres (0,05 – 500) mg/kg\nMetoda spektrofotometryczna Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc fenoli\nZakres (0,05 – 500) mg/kg\nMetoda spektrofotometryczna Normy","categories":["water","environment","food","materials","construction"],"row_index":393,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol content","parameters_en":[{"name":"Range","range":"(0,05 – 500) mg/kg"}],"search_en":"Phenol content Spectrophotometric method Range Normy","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(0,05 – 500) mg/kg"}],"search_zh":"酚类含量 分光光度法 范围 Normy","technique_zh":"分光光度法","methodology_zh":"酚类含量"},{"_id":"6a832b7f884ede9a1b2c5652","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość siarczanów rozpuszczalnych w wodzie Zawartość siarczanów rozpuszczalnych w kwasie","parameters":[{"name":"Zakres","range":"(100 – 50000) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość siarczanów rozpuszczalnych w wodzie Zawartość siarczanów rozpuszczalnych w kwasie\nZakres (100 – 50000) mg/kg\nMetoda wagowa","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość siarczanów rozpuszczalnych w wodzie Zawartość siarczanów rozpuszczalnych w kwasie\nZakres (100 – 50000) mg/kg\nMetoda wagowa Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc siarczanow rozpuszczalnych w wodzie Zawartosc siarczanow rozpuszczalnych w kwasie\nZakres (100 – 50000) mg/kg\nMetoda wagowa Normy","categories":["water","environment","food","materials","construction"],"row_index":394,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of water-soluble sulfates Content of acid-soluble sulfates","parameters_en":[{"name":"Range","range":"(100 – 50000) mg/kg"}],"search_en":"Content of water-soluble sulfates Content of acid-soluble sulfates Gravimetric method Range Normy","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(100 – 50000) mg/kg"}],"search_zh":"重量法 范围 Normy","technique_zh":"重量法"},{"_id":"6a832b7f884ede9a1b2c5653","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość siarczków","parameters":[{"name":"Zakres","range":"(2,0 – 100) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość siarczków\nZakres (2,0 – 100) mg/kg\nMetoda miareczkowa","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość siarczków\nZakres (2,0 – 100) mg/kg\nMetoda miareczkowa Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc siarczkow\nZakres (2,0 – 100) mg/kg\nMetoda miareczkowa Normy","categories":["water","environment","food","materials","construction"],"row_index":395,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfide content","parameters_en":[{"name":"Range","range":"(2,0 – 100) mg/kg"}],"search_en":"Sulfide content Titrimetric method Range Normy","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(2,0 – 100) mg/kg"}],"search_zh":"硫化物含量 滴定法 范围 Normy","technique_zh":"滴定法","methodology_zh":"硫化物含量"},{"_id":"6a832b7f884ede9a1b2c5654","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Sucha masa / zawartość wody 1, 2, 3, 4, 5, 6, 7, 8","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa / zawartość wody 1, 2, 3, 4, 5, 6, 7, 8\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Sucha masa / zawartość wody 1, 2, 3, 4, 5, 6, 7, 8\nZakres (1,0 – 99,0) %\nMetoda wagowa Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Sucha masa / zawartosc wody 1, 2, 3, 4, 5, 6, 7, 8\nZakres (1,0 – 99,0) %\nMetoda wagowa Normy","categories":["water","environment","food","materials","construction"],"row_index":396,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter / water content 1, 2, 3, 4, 5, 6, 7, 8","parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"search_en":"Dry matter / water content 1, 2, 3, 4, 5, 6, 7, 8 Gravimetric method Range Normy","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"重量法 范围 Normy","technique_zh":"重量法"},{"_id":"6a832b7f884ede9a1b2c5655","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,002 – 8,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres (0,002 – 8,00) %\nMetoda miareczkowa","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość azotu Kjeldahla\nZakres (0,002 – 8,00) %\nMetoda miareczkowa Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc azotu Kjeldahla\nZakres (0,002 – 8,00) %\nMetoda miareczkowa Normy","categories":["water","environment","food","materials"],"row_index":397,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,002 – 8,00) %"}],"search_en":"Kjeldahl nitrogen content Titrimetric method Range Normy","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(0,002 – 8,00) %"}],"search_zh":"凯氏氮含量 滴定法 范围 Normy","technique_zh":"滴定法","methodology_zh":"凯氏氮含量"},{"_id":"6a832b7f884ede9a1b2c5656","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Ciepło spalania 1","parameters":[],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania 1\nMetoda kalorymetryczna","reference":"Normy Procedury","norm_bases":["Normy Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Ciepło spalania 1\nMetoda kalorymetryczna Normy Procedury Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Cieplo spalania 1\nMetoda kalorymetryczna Normy Procedury","categories":["water","environment","food","materials","construction"],"row_index":398,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value 1","search_en":"Gross calorific value 1 Calorimetric method Normy Procedury","technique_en":"Calorimetric method","search_zh":"量热法 Normy Procedury","technique_zh":"量热法"},{"_id":"6a832b7f884ede9a1b2c5657","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"Normy Procedury","norm_bases":["Normy Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Wartość opałowa (z obliczeń) Normy Procedury Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Wartosc opalowa (z obliczen) Normy Procedury","categories":["water","environment","food","materials","construction"],"row_index":399,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Net calorific value (calculated) Normy Procedury","methodology_zh":"低位发热量（计算值）","search_zh":"低位发热量（计算值） Normy Procedury"},{"_id":"6a832b7f884ede9a1b2c5658","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość chloru","parameters":[],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość chloru\nMetoda miareczkowa","reference":"Procedury","norm_bases":["Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość chloru\nMetoda miareczkowa Procedury Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc chloru\nMetoda miareczkowa Procedury","categories":["water","environment","food","materials","construction"],"row_index":400,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine content","search_en":"Chlorine content Titrimetric method Procedury","technique_en":"Titrimetric method","search_zh":"氯含量 滴定法 Procedury","technique_zh":"滴定法","methodology_zh":"氯含量"},{"_id":"6a832b7f884ede9a1b2c5659","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość części lotnych","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość części lotnych\nMetoda wagowa","reference":"Normy Procedury","norm_bases":["Normy Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość części lotnych\nMetoda wagowa Normy Procedury Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc czesci lotnych\nMetoda wagowa Normy Procedury","categories":["water","environment","food","materials","construction"],"row_index":401,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile matter content","search_en":"Volatile matter content Gravimetric method Normy Procedury","technique_en":"Gravimetric method","search_zh":"挥发分含量 重量法 Normy Procedury","technique_zh":"重量法","methodology_zh":"挥发分含量"},{"_id":"6a832b7f884ede9a1b2c565a","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość ogólnego węgla organicznego (TOC) 1, 3, 5, 6, 7, 8","parameters":[{"name":"Zakres","range":"(0,50 – 60) %"},{"name":"Zakres","range":"(5000 – 600000) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość ogólnego węgla organicznego (TOC) 1, 3, 5, 6, 7, 8\nZakres:\nZakres (0,50 – 60) %\nZakres (5000 – 600000) mg/kg\nMetoda miareczkowa","reference":"Procedury","norm_bases":["Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość ogólnego węgla organicznego (TOC) 1, 3, 5, 6, 7, 8\nZakres:\nZakres (0,50 – 60) %\nZakres (5000 – 600000) mg/kg\nMetoda miareczkowa Procedury Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc ogolnego wegla organicznego (TOC) 1, 3, 5, 6, 7, 8\nZakres:\nZakres (0,50 – 60) %\nZakres (5000 – 600000) mg/kg\nMetoda miareczkowa Procedury","categories":["water","environment","food","materials","construction"],"row_index":402,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon (TOC) content 1, 3, 5, 6, 7, 8","parameters_en":[{"name":"Range","range":"(0,50 – 60) %"},{"name":"Range","range":"(5000 – 600000) mg/kg"}],"search_en":"Total organic carbon (TOC) content 1, 3, 5, 6, 7, 8 Titrimetric method Range Range Procedury","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(0,50 – 60) %"},{"name":"范围","range":"(5000 – 600000) mg/kg"}],"search_zh":"滴定法 范围 范围 Procedury","technique_zh":"滴定法"},{"_id":"6a832b7f884ede9a1b2c565b","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość popiołu / pozostałość po spaleniu","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu / pozostałość po spaleniu\nMetoda wagowa","reference":"Normy Procedury","norm_bases":["Normy Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość popiołu / pozostałość po spaleniu\nMetoda wagowa Normy Procedury Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc popiolu / pozostalosc po spaleniu\nMetoda wagowa Normy Procedury","categories":["water","environment","food","materials","construction"],"row_index":403,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content / residue on ignition","search_en":"Ash content / residue on ignition Gravimetric method Normy Procedury","technique_en":"Gravimetric method","search_zh":"灰分含量/燃烧残渣 重量法 Normy Procedury","technique_zh":"重量法","methodology_zh":"灰分含量/燃烧残渣"},{"_id":"6a832b7f884ede9a1b2c565c","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość siarki","parameters":[],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"Normy Procedury","norm_bases":["Normy Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość siarki\nMetoda wysokotemperaturowego spalania z detekcją IR Normy Procedury Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc siarki\nMetoda wysokotemperaturowego spalania z detekcja IR Normy Procedury","categories":["water","environment","food","materials","construction"],"row_index":404,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","search_en":"Sulfur content High-temperature combustion with IR detection Normy Procedury","technique_en":"High-temperature combustion with IR detection","search_zh":"硫含量 高温燃烧红外检测法 Normy Procedury","technique_zh":"高温燃烧红外检测法","methodology_zh":"硫含量"},{"_id":"6a832b7f884ede9a1b2c565d","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość węgla, wodoru","parameters":[],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla, wodoru\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"Normy Procedury","norm_bases":["Normy Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość węgla, wodoru\nMetoda wysokotemperaturowego spalania z detekcją IR Normy Procedury Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc wegla, wodoru\nMetoda wysokotemperaturowego spalania z detekcja IR Normy Procedury","categories":["water","environment","food","materials","construction"],"row_index":405,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon, hydrogen content","search_en":"Carbon, hydrogen content High-temperature combustion with IR detection Normy Procedury","technique_en":"High-temperature combustion with IR detection","search_zh":"碳、氢含量 高温燃烧红外检测法 Normy Procedury","technique_zh":"高温燃烧红外检测法","methodology_zh":"碳、氢含量"},{"_id":"6a832b7f884ede9a1b2c565e","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(1,0 – 85,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (1,0 – 85,0) %\nMetoda wagowa","reference":"Normy Procedury","norm_bases":["Normy Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość wilgoci całkowitej\nZakres (1,0 – 85,0) %\nMetoda wagowa Normy Procedury Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc wilgoci calkowitej\nZakres (1,0 – 85,0) %\nMetoda wagowa Normy Procedury","categories":["water","environment","food","materials","construction"],"row_index":406,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(1,0 – 85,0) %"}],"search_en":"Total moisture content Gravimetric method Range Normy Procedury","technique_en":"Gravimetric method","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 85,0) %"}],"search_zh":"全水分含量 重量法 范围 Normy Procedury","technique_zh":"重量法"},{"_id":"6a832b7f884ede9a1b2c565f","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość wilgoci przemijającej","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci przemijającej\nMetoda wagowa","reference":"Procedury","norm_bases":["Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość wilgoci przemijającej\nMetoda wagowa Procedury Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc wilgoci przemijajacej\nMetoda wagowa Procedury","categories":["water","environment","food","materials","construction"],"row_index":407,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free moisture content","search_en":"Free moisture content Gravimetric method Procedury","technique_en":"Gravimetric method","search_zh":"外在水分含量 重量法 Procedury","technique_zh":"重量法","methodology_zh":"外在水分含量"},{"_id":"6a832b7f884ede9a1b2c5660","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zawartość wilgoci w próbce analitycznej"}],"technique":"Metoda wagowa; Metoda wagowa","techniques":["Metoda wagowa","Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nMetoda wagowa; Metoda wagowa","reference":"Normy Procedury","norm_bases":["Normy Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość wilgoci w próbce analitycznej\nMetoda wagowa; Metoda wagowa Normy Procedury Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc wilgoci w probce analitycznej\nMetoda wagowa; Metoda wagowa Normy Procedury","categories":["water","environment","food","materials","construction"],"row_index":408,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Moisture content in the analytical sample"}],"search_en":"Moisture content in the analytical sample Gravimetric method; Gravimetric method Moisture content in the analytical sample Normy Procedury","technique_en":"Gravimetric method; Gravimetric method","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"分析样品水分含量"}],"search_zh":"分析样品水分含量 重量法；重量法 分析样品水分含量 Normy Procedury","technique_zh":"重量法；重量法"},{"_id":"6a832b7f884ede9a1b2c5661","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość chromu (VI)","parameters":[{"name":"Zakres","range":"(0,10 – 50,0) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość chromu (VI)\nZakres (0,10 – 50,0) mg/kg\nMetoda spektrofotometryczna","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość chromu (VI)\nZakres (0,10 – 50,0) mg/kg\nMetoda spektrofotometryczna Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc chromu (VI)\nZakres (0,10 – 50,0) mg/kg\nMetoda spektrofotometryczna Normy","categories":["water","environment","food","materials","construction"],"row_index":409,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) content","parameters_en":[{"name":"Range","range":"(0,10 – 50,0) mg/kg"}],"search_en":"Chromium(VI) content Spectrophotometric method Range Normy","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(0,10 – 50,0) mg/kg"}],"search_zh":"铬(VI)含量 分光光度法 范围 Normy","technique_zh":"分光光度法","methodology_zh":"铬(VI)含量"},{"_id":"6a832b7f884ede9a1b2c5662","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość chromu (III) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość chromu (III) (z obliczeń)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość chromu (III) (z obliczeń) Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc chromu (III) (z obliczen) Normy","categories":["water","environment","food","materials","construction"],"row_index":410,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium (III) content (calculated)","search_en":"Chromium (III) content (calculated) Normy"},{"_id":"6a832b7f884ede9a1b2c5663","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość pierwiastków 1, 3, 5","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość pierwiastków 1, 3, 5\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość pierwiastków 1, 3, 5\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc pierwiastkow 1, 3, 5\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) Normy","categories":["water","environment","food","materials","construction"],"row_index":411,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content 1, 3, 5","search_en":"Element content 1, 3, 5 Inductively coupled plasma mass spectrometry (ICP-MS) Normy","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","search_zh":"电感耦合等离子体质谱法（ICP-MS） Normy","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a832b7f884ede9a1b2c5664","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość rozpuszczonego węgla organicznego (DOC) 1, 3, 5","parameters":[],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Zawartość rozpuszczonego węgla organicznego (DOC) 1, 3, 5\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość rozpuszczonego węgla organicznego (DOC) 1, 3, 5\nMetoda spektrometrii w zakresie podczerwieni IR Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc rozpuszczonego wegla organicznego (DOC) 1, 3, 5\nMetoda spektrometrii w zakresie podczerwieni IR Normy","categories":["water","environment","food","materials","construction"],"row_index":412,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of dissolved organic carbon (DOC) 1, 3, 5","search_en":"Content of dissolved organic carbon (DOC) 1, 3, 5 Spectrometry method in the infrared range IR Normy","technique_en":"Spectrometry method in the infrared range IR","search_zh":"红外光谱法 IR Normy","technique_zh":"红外光谱法 IR"},{"_id":"6a832b7f884ede9a1b2c5665","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość rtęci 1, 3, 5","parameters":[{"name":"Zakres","range":"(0,005 – 5,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zawartość rtęci 1, 3, 5\nZakres (0,005 – 5,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość rtęci 1, 3, 5\nZakres (0,005 – 5,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc rteci 1, 3, 5\nZakres (0,005 – 5,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) Normy","categories":["water","environment","food","materials","construction"],"row_index":413,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content 1, 3, 5","parameters_en":[{"name":"Range","range":"(0,005 – 5,0) mg/kg"}],"search_en":"Mercury content 1, 3, 5 Cold vapour atomic absorption spectrometry (CVAAS) Range Normy","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","parameters_zh":[{"name":"范围","range":"(0,005 – 5,0) mg/kg"}],"search_zh":"冷蒸气原子吸收光谱法（CVAAS） 范围 Normy","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a832b7f884ede9a1b2c5666","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość oleju mineralnego 1, 3, 4, 5","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość oleju mineralnego 1, 3, 4, 5\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość oleju mineralnego 1, 3, 4, 5\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc oleju mineralnego 1, 3, 4, 5\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy","categories":["water","environment","food","materials","petro","construction"],"row_index":414,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil content 1, 3, 4, 5","search_en":"Mineral oil content 1, 3, 4, 5 Gas chromatography with flame ionization detection (GC-FID) Normy","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） Normy","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a832b7f884ede9a1b2c5667","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość pierwiastków 1, 3, 5","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków 1, 3, 5\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość pierwiastków 1, 3, 5\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc pierwiastkow 1, 3, 5\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Normy","categories":["water","environment","food","materials","construction"],"row_index":415,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content 1, 3, 5","search_en":"Element content 1, 3, 5 Inductively coupled plasma optical emission spectrometry (ICP-OES) Normy","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","search_zh":"电感耦合等离子体原子发射光谱法（ICP-OES） Normy","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a832b7f884ede9a1b2c5668","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość rtęci 1, 3, 5","parameters":[{"name":"Zakres","range":"(0,05 – 25,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zawartość rtęci 1, 3, 5\nZakres (0,05 – 25,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość rtęci 1, 3, 5\nZakres (0,05 – 25,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) Normy Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc rteci 1, 3, 5\nZakres (0,05 – 25,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) Normy","categories":["water","environment","food","materials","construction"],"row_index":416,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content 1, 3, 5","parameters_en":[{"name":"Range","range":"(0,05 – 25,0) mg/kg"}],"search_en":"Mercury content 1, 3, 5 Cold vapour atomic absorption spectrometry (CVAAS) Range Normy","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","parameters_zh":[{"name":"范围","range":"(0,05 – 25,0) mg/kg"}],"search_zh":"冷蒸气原子吸收光谱法（CVAAS） 范围 Normy","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a832b7f884ede9a1b2c5669","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA) 1,3,5","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA) 1,3,5\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"Procedury","norm_bases":["Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA) 1,3,5\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Procedury Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA) 1,3,5\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) Procedury","categories":["water","environment","food","materials","construction"],"row_index":417,"parse_version":4,"parse_source":"agent-claude-code","search_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Procedury","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","search_zh":"高效液相色谱-荧光检测法（HPLC-FLD） Procedury","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）"},{"_id":"6a832b7f884ede9a1b2c566a","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość benzyny (C6-C12)","parameters":[{"name":"Zakres","range":"(1,0 – 750) mg/kg"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Zawartość benzyny (C6-C12)\nZakres (1,0 – 750) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"Normy Procedury","norm_bases":["Normy Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość benzyny (C6-C12)\nZakres (1,0 – 750) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID) Normy Procedury Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc benzyny (C6-C12)\nZakres (1,0 – 750) mg/kg\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej z detekcja plomieniowo-jonizacyjna (HS-GC-FID) Normy Procedury","categories":["water","environment","food","materials","construction"],"row_index":418,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Petrol content (C6-C12)","parameters_en":[{"name":"Range","range":"(1,0 – 750) mg/kg"}],"search_en":"Petrol content (C6-C12) Headspace gas chromatography with flame ionization detection (HS-GC-FID) Range Normy Procedury","technique_en":"Headspace gas chromatography with flame ionization detection (HS-GC-FID)","parameters_zh":[{"name":"范围","range":"(1,0 – 750) mg/kg"}],"search_zh":"汽油（C6-C12）含量 顶空气相色谱-火焰离子化检测法（HS-GC-FID） 范围 Normy Procedury","technique_zh":"顶空气相色谱-火焰离子化检测法（HS-GC-FID）","methodology_zh":"汽油（C6-C12）含量"},{"_id":"6a832b7f884ede9a1b2c566b","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość lotnych węglowodorów aromatycznych (BTX) 1, 3","parameters":[{"name":"benzen","range":"(0,020 – 15) mg/kg"},{"name":"etylobenzen","range":"(0,020 – 15) mg/kg"},{"name":"toluen","range":"(0,020 – 15) mg/kg"},{"name":"suma ksylenów","range":"(0,020 – 45) mg/kg"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Zawartość lotnych węglowodorów aromatycznych (BTX) 1, 3\nZakres:\nbenzen (0,020 – 15) mg/kg\netylobenzen (0,020 – 15) mg/kg\ntoluen (0,020 – 15) mg/kg\nsuma ksylenów (0,020 – 45) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"Normy Procedury","norm_bases":["Normy Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość lotnych węglowodorów aromatycznych (BTX) 1, 3\nZakres:\nbenzen (0,020 – 15) mg/kg\netylobenzen (0,020 – 15) mg/kg\ntoluen (0,020 – 15) mg/kg\nsuma ksylenów (0,020 – 45) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID) Normy Procedury Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc lotnych weglowodorow aromatycznych (BTX) 1, 3\nZakres:\nbenzen (0,020 – 15) mg/kg\netylobenzen (0,020 – 15) mg/kg\ntoluen (0,020 – 15) mg/kg\nsuma ksylenow (0,020 – 45) mg/kg\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej z detekcja plomieniowo-jonizacyjna (HS-GC-FID) Normy Procedury","categories":["water","environment","food","materials","construction"],"row_index":419,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile aromatic hydrocarbon (BTX) content 1, 3","parameters_en":[{"name":"benzene","range":"(0,020 – 15) mg/kg"},{"name":"ethylbenzene","range":"(0,020 – 15) mg/kg"},{"name":"toluene","range":"(0,020 – 15) mg/kg"},{"name":"sum of xylenes","range":"(0,020 – 45) mg/kg"}],"search_en":"Volatile aromatic hydrocarbon (BTX) content 1, 3 Headspace gas chromatography with flame ionization detection (HS-GC-FID) benzene ethylbenzene toluene sum of xylenes Normy Procedury","technique_en":"Headspace gas chromatography with flame ionization detection (HS-GC-FID)","parameters_zh":[{"name":"苯","range":"(0,020 – 15) mg/kg"},{"name":"乙苯","range":"(0,020 – 15) mg/kg"},{"name":"甲苯","range":"(0,020 – 15) mg/kg"},{"name":"二甲苯总量","range":"(0,020 – 45) mg/kg"}],"search_zh":"顶空气相色谱-火焰离子化检测法（HS-GC-FID） 苯 乙苯 甲苯 二甲苯总量 Normy Procedury","technique_zh":"顶空气相色谱-火焰离子化检测法（HS-GC-FID）"},{"_id":"6a832b7f884ede9a1b2c566c","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość polichlorowanych bifenyli (PCB) 1, 3, 5","parameters":[{"name":"PCB 28","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 52","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 101","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 118","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 138","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 153","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 180","range":"(0,020 – 2,5) mg/kg"},{"name":"Suma polichlorowanych bifenyli (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Zawartość polichlorowanych bifenyli (PCB) 1, 3, 5\nZakres:\nPCB 28 (0,020 – 2,5) mg/kg\nPCB 52 (0,020 – 2,5) mg/kg\nPCB 101 (0,020 – 2,5) mg/kg\nPCB 118 (0,020 – 2,5) mg/kg\nPCB 138 (0,020 – 2,5) mg/kg\nPCB 153 (0,020 – 2,5) mg/kg\nPCB 180 (0,020 – 2,5) mg/kg\nSuma polichlorowanych bifenyli (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"Procedury","norm_bases":["Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: 1.Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz. 1277) 2.Rozporządzenie Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie komunalnych osadów ściekowych (Dz. U. z 2015 r poz. 257) 3.Rozporządzenie Ministra Środowiska z dnia 15 lipca 2011 r. w sprawie kryteriów zaliczania odpadów wydobywczych do odpadów obojętnych (Dz. U. z 2011 r., nr 175 poz. 1048) 4.Rozporządzenie Ministra Środowiska z dnia 20 stycznia 2015 r. w sprawie procesu odzysku R10 (Dz. U. z 2015 r. poz. 132) 5.Rozporządzenie Ministra Środowiska z dnia 11 maja 2015 r. w sprawie odzysku odpadów poza instalacjami i urządzeniami (Dz. U. z 2015 r. poz. 796) 6.Rozporządzenie Ministra Środowiska z dnia 8 czerwca 2016 r. w sprawie warunków technicznych kwalifikowania części energii odzyskanej z termicznego przekształcania odpadów (Dz. U. z 2016 r. poz. 847) 7.Rozporządzeniem Rady Ministrów z dnia 22 grudnia 2017 roku w sprawie jednostkowych stawek opłat za korzystanie ze środowiska (Dz. U. 2017, poz. 2490) 8.Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56)","flexible":false,"search_text":"Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość polichlorowanych bifenyli (PCB) 1, 3, 5\nZakres:\nPCB 28 (0,020 – 2,5) mg/kg\nPCB 52 (0,020 – 2,5) mg/kg\nPCB 101 (0,020 – 2,5) mg/kg\nPCB 118 (0,020 – 2,5) mg/kg\nPCB 138 (0,020 – 2,5) mg/kg\nPCB 153 (0,020 – 2,5) mg/kg\nPCB 180 (0,020 – 2,5) mg/kg\nSuma polichlorowanych bifenyli (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) Procedury Odpady DAB-11: E - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11.; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc polichlorowanych bifenyli (PCB) 1, 3, 5\nZakres:\nPCB 28 (0,020 – 2,5) mg/kg\nPCB 52 (0,020 – 2,5) mg/kg\nPCB 101 (0,020 – 2,5) mg/kg\nPCB 118 (0,020 – 2,5) mg/kg\nPCB 138 (0,020 – 2,5) mg/kg\nPCB 153 (0,020 – 2,5) mg/kg\nPCB 180 (0,020 – 2,5) mg/kg\nSuma polichlorowanych bifenyli (z obliczen)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) Procedury","categories":["water","environment","food","materials","construction"],"row_index":420,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polychlorinated biphenyl (PCB) content 1, 3, 5","parameters_en":[{"name":"PCB 28","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 52","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 101","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 118","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 138","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 153","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 180","range":"(0,020 – 2,5) mg/kg"},{"name":"Sum of polychlorinated biphenyls (calculated)"}],"search_en":"Polychlorinated biphenyl (PCB) content 1, 3, 5 Gas chromatography with electron capture detection (GC-ECD) PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 Sum of polychlorinated biphenyls (calculated) Procedury","technique_en":"Gas chromatography with electron capture detection (GC-ECD)","search_zh":"气相色谱-电子捕获检测法（GC-ECD） PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 多氯联苯总量（由计算得出） Procedury","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","parameters_zh":[{"name":"PCB 28","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 52","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 101","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 118","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 138","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 153","range":"(0,020 – 2,5) mg/kg"},{"name":"PCB 180","range":"(0,020 – 2,5) mg/kg"},{"name":"多氯联苯总量（由计算得出）"}]},{"_id":"6a832b7f884ede9a1b2c566d","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludziE, ŚciekiE; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Stężenie pestycydów","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Stężenie pestycydów\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"Procedury","norm_bases":["Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda E, Woda do spożycia przez ludziE, ŚciekiE; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Stężenie pestycydów\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) Procedury Woda E, Woda do spozycia przez ludziE, SciekiE; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Stezenie pestycydow\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) Procedury","categories":["water"],"row_index":421,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pesticide concentration","search_en":"Pesticide concentration Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) Procedury","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","methodology_zh":"农药浓度","search_zh":"农药浓度 气相色谱-串联质谱法（GC-MS-MS） Procedury","technique_zh":"气相色谱-串联质谱法（GC-MS-MS）"},{"_id":"6a832b7f884ede9a1b2c566e","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludziE, ŚciekiE; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Stężenie pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda E, Woda do spożycia przez ludziE, ŚciekiE; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Stężenie pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) Normy Woda E, Woda do spozycia przez ludziE, SciekiE; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Stezenie pierwiastkow\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) Normy","categories":["water"],"row_index":422,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","search_en":"Element concentration Inductively coupled plasma mass spectrometry (ICP-MS) Normy","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","methodology_zh":"元素浓度","search_zh":"元素浓度 电感耦合等离子体质谱法（ICP-MS） Normy","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a832b7f884ede9a1b2c566f","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludziE, ŚciekiE; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Stężenie pierwiastków","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda E, Woda do spożycia przez ludziE, ŚciekiE; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Stężenie pierwiastków\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Normy Woda E, Woda do spozycia przez ludziE, SciekiE; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Stezenie pierwiastkow\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Normy","categories":["water"],"row_index":423,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","search_en":"Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Normy","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","methodology_zh":"元素浓度","search_zh":"元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） Normy","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a832b7f884ede9a1b2c5670","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludziE, ŚciekiE; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda E, Woda do spożycia przez ludziE, ŚciekiE; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Normy Woda E, Woda do spozycia przez ludziE, SciekiE; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) Normy","categories":["water"],"row_index":424,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","search_en":"Concentration of polycyclic aromatic hydrocarbons (PAH) High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Normy","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","search_zh":"多环芳烃（PAHs）浓度 高效液相色谱-荧光检测法（HPLC-FLD） Normy","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","methodology_zh":"多环芳烃（PAHs）浓度"},{"_id":"6a832b7f884ede9a1b2c5671","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość pierwiastków","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość pierwiastków\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Normy Gleba E; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc pierwiastkow\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Normy","categories":["environment"],"row_index":425,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","search_en":"Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) Normy","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","methodology_zh":"元素含量","search_zh":"元素含量 电感耦合等离子体原子发射光谱法（ICP-OES） Normy","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a832b7f884ede9a1b2c5672","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Stężenie pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Stężenie pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) Normy Gleba, grunty E; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Stezenie pierwiastkow\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) Normy","categories":["environment"],"row_index":426,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","search_en":"Element concentration Inductively coupled plasma mass spectrometry (ICP-MS) Normy","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","methodology_zh":"元素浓度","search_zh":"元素浓度 电感耦合等离子体质谱法（ICP-MS） Normy","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a832b7f884ede9a1b2c5673","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość ogólnego węgla organicznego (TOC)","parameters":[{"name":"Zakres","range":"(0,10 – 60) %"},{"name":"Zakres","range":"(1000 – 600000) mg/kg"}],"technique":"Metoda wysoko temperaturowego spalania z detekcją IR","techniques":["Metoda wysoko temperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość ogólnego węgla organicznego (TOC)\nZakres:\nZakres (0,10 – 60) %\nZakres (1000 – 600000) mg/kg\nMetoda wysoko temperaturowego spalania z detekcją IR","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość ogólnego węgla organicznego (TOC)\nZakres:\nZakres (0,10 – 60) %\nZakres (1000 – 600000) mg/kg\nMetoda wysoko temperaturowego spalania z detekcją IR Normy Gleba E; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc ogolnego wegla organicznego (TOC)\nZakres:\nZakres (0,10 – 60) %\nZakres (1000 – 600000) mg/kg\nMetoda wysoko temperaturowego spalania z detekcja IR Normy","categories":["environment"],"row_index":427,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon (TOC) content","parameters_en":[{"name":"Range","range":"(0,10 – 60) %"},{"name":"Range","range":"(1000 – 600000) mg/kg"}],"search_en":"Total organic carbon (TOC) content High-temperature combustion with IR detection Range Range Normy","technique_en":"High-temperature combustion with IR detection","parameters_zh":[{"name":"范围","range":"(0,10 – 60) %"},{"name":"范围","range":"(1000 – 600000) mg/kg"}],"search_zh":"总有机碳（TOC）含量 高温燃烧-红外检测法 范围 范围 Normy","methodology_zh":"总有机碳（TOC）含量","technique_zh":"高温燃烧-红外检测法"},{"_id":"6a832b7f884ede9a1b2c5674","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady denne E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość pierwiastków","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Normy Procedury","norm_bases":["Normy Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość pierwiastków\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Normy Procedury Osady denne E; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc pierwiastkow\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Normy Procedury","categories":["water"],"row_index":428,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","search_en":"Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) Normy Procedury","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","methodology_zh":"元素含量","search_zh":"元素含量 电感耦合等离子体原子发射光谱法（ICP-OES） Normy Procedury","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a832b7f884ede9a1b2c5675","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady denne E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"Procedury","norm_bases":["Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Procedury Osady denne E; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) Procedury","categories":["water"],"row_index":429,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polycyclic aromatic hydrocarbons (PAH) content","search_en":"Polycyclic aromatic hydrocarbons (PAH) content High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Procedury","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","search_zh":"多环芳烃（PAHs）含量 高效液相色谱-荧光检测法（HPLC-FLD） Procedury","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","methodology_zh":"多环芳烃（PAHs）含量"},{"_id":"6a832b7f884ede9a1b2c5676","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady ściekoweE; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość pierwiastków antymon, arsen, bar, beryl, bizmut, bor, chrom, cyna, cynk, fosfor, glin, kadm, krzem, kobalt, magnez, mangan, miedź, molibden, nikiel, ołów, potas, sód, srebro, stront, tal, tytan, wanad, wapń, żelazo","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES); Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków antymon, arsen, bar, beryl, bizmut, bor, chrom, cyna, cynk, fosfor, glin, kadm, krzem, kobalt, magnez, mangan, miedź, molibden, nikiel, ołów, potas, sód, srebro, stront, tal, tytan, wanad, wapń, żelazo\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES); Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekoweE; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość pierwiastków antymon, arsen, bar, beryl, bizmut, bor, chrom, cyna, cynk, fosfor, glin, kadm, krzem, kobalt, magnez, mangan, miedź, molibden, nikiel, ołów, potas, sód, srebro, stront, tal, tytan, wanad, wapń, żelazo\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES); Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Normy Osady sciekoweE; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc pierwiastkow antymon, arsen, bar, beryl, bizmut, bor, chrom, cyna, cynk, fosfor, glin, kadm, krzem, kobalt, magnez, mangan, miedz, molibden, nikiel, olow, potas, sod, srebro, stront, tal, tytan, wanad, wapn, zelazo\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES); Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Normy","categories":["water","materials"],"row_index":430,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of elements antimony, arsenic, barium, beryllium, bismuth, boron, chromium, tin, zinc, phosphorus, aluminium, cadmium, silicon, cobalt, magnesium, manganese, copper, molybdenum, nickel, lead, potassium, sodium, silver, strontium, thallium, titanium, vanadium, calcium, iron","search_en":"Content of elements antimony, arsenic, barium, beryllium, bismuth, boron, chromium, tin, zinc, phosphorus, aluminium, cadmium, silicon, cobalt, magnesium, manganese, copper, molybdenum, nickel, lead, potassium, sodium, silver, strontium, thallium, titanium, vanadium, calcium, iron Inductively coupled plasma atomic emission spectrometry (ICP-OES); Inductively coupled plasma atomic emission spectrometry (ICP-OES) Normy","technique_en":"Inductively coupled plasma atomic emission spectrometry (ICP-OES); Inductively coupled plasma atomic emission spectrometry (ICP-OES)"},{"_id":"6a832b7f884ede9a1b2c5677","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałeE: paliwo wtórne, paliwo alternatywne, biomasa stała, biopaliwo stałe; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość pierwiastków","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Procedury","norm_bases":["Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałeE: paliwo wtórne, paliwo alternatywne, biomasa stała, biopaliwo stałe; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość pierwiastków\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Procedury Paliwa staleE: paliwo wtorne, paliwo alternatywne, biomasa stala, biopaliwo stale; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc pierwiastkow\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Procedury","categories":["petro"],"row_index":431,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","search_en":"Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedury","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","methodology_zh":"元素含量","search_zh":"元素含量 电感耦合等离子体原子发射光谱法（ICP-OES） Procedury","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a832b7f884ede9a1b2c5678","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko ogólneE: - próbki gazów odlotowych pobrane do roztworu pochłaniającego, - próbki gazów odlotowych pobrane na filtry; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Stężenie metali: antymon, arsen, kadm, miedź, ołów, cynk, chrom, kobalt, nikiel, mangan, wanad, tal","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie metali: antymon, arsen, kadm, miedź, ołów, cynk, chrom, kobalt, nikiel, mangan, wanad, tal\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólneE: - próbki gazów odlotowych pobrane do roztworu pochłaniającego, - próbki gazów odlotowych pobrane na filtry; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Stężenie metali: antymon, arsen, kadm, miedź, ołów, cynk, chrom, kobalt, nikiel, mangan, wanad, tal\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Normy Srodowisko ogolneE: - probki gazow odlotowych pobrane do roztworu pochlaniajacego, - probki gazow odlotowych pobrane na filtry; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Stezenie metali: antymon, arsen, kadm, miedz, olow, cynk, chrom, kobalt, nikiel, mangan, wanad, tal\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Normy","categories":["materials","environment"],"row_index":432,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES) Normy","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","search_zh":"电感耦合等离子体原子发射光谱法（ICP-OES） Normy","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a832b7f884ede9a1b2c5679","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko ogólneE: - próbki gazów odlotowych pobrane do roztworu pochłaniającego, - próbki gazów odlotowych pobrane na filtry; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Stężenie metali","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie metali\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Procedury","norm_bases":["Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólneE: - próbki gazów odlotowych pobrane do roztworu pochłaniającego, - próbki gazów odlotowych pobrane na filtry; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Stężenie metali\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Procedury Srodowisko ogolneE: - probki gazow odlotowych pobrane do roztworu pochlaniajacego, - probki gazow odlotowych pobrane na filtry; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Stezenie metali\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Procedury","categories":["materials","environment"],"row_index":433,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","search_en":"Metal concentrations Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedury","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","methodology_zh":"金属浓度","search_zh":"金属浓度 电感耦合等离子体原子发射光谱法（ICP-OES） Procedury","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a832b7f884ede9a1b2c567a","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko ogólneE: - próbki powietrza pobrane do roztworu pochłaniającego, - próbki powietrza pobrane na filtry; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Stężenie metali","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie metali\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Procedury","norm_bases":["Procedury"],"lab_section":"Laboratorium; Siedziba Główna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólneE: - próbki powietrza pobrane do roztworu pochłaniającego, - próbki powietrza pobrane na filtry; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Stężenie metali\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Procedury Srodowisko ogolneE: - probki powietrza pobrane do roztworu pochlaniajacego, - probki powietrza pobrane na filtry; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Stezenie metali\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Procedury","categories":["materials","environment"],"row_index":434,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","search_en":"Metal concentrations Inductively coupled plasma optical emission spectrometry (ICP-OES) Procedury","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","methodology_zh":"金属浓度","search_zh":"金属浓度 电感耦合等离子体原子发射光谱法（ICP-OES） Procedury","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a832b7f884ede9a1b2c567b","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gazy składowiskowe, Biogaz","methodology":"Prędkość przepływu","parameters":[{"name":"Zakres","range":"(0,15 – 10) m/s"}],"technique":"Metoda termoanemometryczna","techniques":["Metoda termoanemometryczna"],"computed":[],"activity":"Prędkość przepływu\nZakres (0,15 – 10) m/s\nMetoda termoanemometryczna","reference":"EFO/PB/36/A:05.05.2025","norm_bases":["EFO/PB/36/A:05.05.2025"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe, Biogaz Prędkość przepływu\nZakres (0,15 – 10) m/s\nMetoda termoanemometryczna EFO/PB/36/A:05.05.2025 Gazy skladowiskowe, Biogaz Predkosc przeplywu\nZakres (0,15 – 10) m/s\nMetoda termoanemometryczna EFO/PB/36/A:05.05.2025","categories":["other"],"row_index":435,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flow velocity","parameters_en":[{"name":"Range","range":"(0,15 – 10) m/s"}],"search_en":"Landfill gases, Biogas Flow velocity Thermoanemometric method Range EFO/PB/36/A:05.05.2025","technique_en":"Thermoanemometric method","test_object_en":"Landfill gases, Biogas","parameters_zh":[{"name":"范围","range":"(0,15 – 10) m/s"}],"search_zh":"填埋气、沼气 流速 热线风速仪法 范围 EFO/PB/36/A:05.05.2025","methodology_zh":"流速","technique_zh":"热线风速仪法","test_object_zh":"填埋气、沼气"},{"_id":"6a832b7f884ede9a1b2c567c","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gazy składowiskowe, Biogaz","methodology":"Stężenie: tlenu, tlenku węgla, dwutlenku węgla, metanu","parameters":[{"name":"O2","range":"(1,0 – 21) %"},{"name":"CO","range":"(1,3 – 150) mg/m3"},{"name":"CO2","range":"(1,0 – 36) %"},{"name":"CH4","range":"(1,0 – 60) %"}],"technique":"Metoda elektrochemiczna; Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda elektrochemiczna","Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie: tlenu, tlenku węgla, dwutlenku węgla, metanu\nZakres:\nO2 (1,0 – 21) %\nCO (1,3 – 150) mg/m3\nCO2 (1,0 – 36) %\nCH4 (1,0 – 60) %\nMetoda elektrochemiczna; Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"EFO/PB/36/A:05.05.2025","norm_bases":["EFO/PB/36/A:05.05.2025"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe, Biogaz Stężenie: tlenu, tlenku węgla, dwutlenku węgla, metanu\nZakres:\nO2 (1,0 – 21) %\nCO (1,3 – 150) mg/m3\nCO2 (1,0 – 36) %\nCH4 (1,0 – 60) %\nMetoda elektrochemiczna; Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) EFO/PB/36/A:05.05.2025 Gazy skladowiskowe, Biogaz Stezenie: tlenu, tlenku wegla, dwutlenku wegla, metanu\nZakres:\nO2 (1,0 – 21) %\nCO (1,3 – 150) mg/m3\nCO2 (1,0 – 36) %\nCH4 (1,0 – 60) %\nMetoda elektrochemiczna; Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) EFO/PB/36/A:05.05.2025","categories":["other"],"row_index":436,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of: oxygen, carbon monoxide, carbon dioxide, methane","parameters_en":[{"name":"O2","range":"(1,0 – 21) %"},{"name":"CO","range":"(1,3 – 150) mg/m3"},{"name":"CO2","range":"(1,0 – 36) %"},{"name":"CH4","range":"(1,0 – 60) %"}],"search_en":"Landfill gases, Biogas Concentration of: oxygen, carbon monoxide, carbon dioxide, methane Electrochemical method; Non-dispersive infrared spectrometry (NDIR) O2 CO CO2 CH4 EFO/PB/36/A:05.05.2025","technique_en":"Electrochemical method; Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Landfill gases, Biogas","parameters_zh":[{"name":"O2","range":"(1,0 – 21) %"},{"name":"CO","range":"(1,3 – 150) mg/m3"},{"name":"CO2","range":"(1,0 – 36) %"},{"name":"CH4","range":"(1,0 – 60) %"}],"search_zh":"填埋气、沼气 电化学法；非分散红外光谱法（NDIR） O2 CO CO2 EFO/PB/36/A:05.05.2025","test_object_zh":"填埋气、沼气","technique_zh":"电化学法；非分散红外光谱法（NDIR）"},{"_id":"6a832b7f884ede9a1b2c567d","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gazy składowiskowe, Biogaz","methodology":"Emisja: CO, CO2, CH4 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja: CO, CO2, CH4 (z obliczeń)","reference":"EFO/PB/36/A:05.05.2025","norm_bases":["EFO/PB/36/A:05.05.2025"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe, Biogaz Emisja: CO, CO2, CH4 (z obliczeń) EFO/PB/36/A:05.05.2025 Gazy skladowiskowe, Biogaz Emisja: CO, CO2, CH4 (z obliczen) EFO/PB/36/A:05.05.2025","categories":["environment"],"row_index":437,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission: CO, CO2, CH4 (calculated)","search_en":"Landfill gases, Biogas Emission: CO, CO2, CH4 (calculated) EFO/PB/36/A:05.05.2025","test_object_en":"Landfill gases, Biogas","search_zh":"填埋气、沼气 EFO/PB/36/A:05.05.2025","test_object_zh":"填埋气、沼气"},{"_id":"6a832b7f884ede9a1b2c567e","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gazy składowiskowe, Biogaz","methodology":"Pomiar temperatury","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) oC"}],"technique":"Metoda termoelektryczna","techniques":["Metoda termoelektryczna"],"computed":[],"activity":"Pomiar temperatury\nZakres (0,0 – 50,0) oC\nMetoda termoelektryczna","reference":"EFO/PB/36/A:05.05.2025","norm_bases":["EFO/PB/36/A:05.05.2025"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe, Biogaz Pomiar temperatury\nZakres (0,0 – 50,0) oC\nMetoda termoelektryczna EFO/PB/36/A:05.05.2025 Gazy skladowiskowe, Biogaz Pomiar temperatury\nZakres (0,0 – 50,0) oC\nMetoda termoelektryczna EFO/PB/36/A:05.05.2025","categories":["other"],"row_index":438,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature measurement","parameters_en":[{"name":"Range","range":"(0,0 – 50,0) oC"}],"search_en":"Landfill gases, Biogas Temperature measurement Thermoelectric method Range EFO/PB/36/A:05.05.2025","technique_en":"Thermoelectric method","test_object_en":"Landfill gases, Biogas","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) oC"}],"search_zh":"填埋气、沼气 范围 EFO/PB/36/A:05.05.2025","test_object_zh":"填埋气、沼气"},{"_id":"6a832b7f884ede9a1b2c567f","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gazy składowiskowe, Biogaz","methodology":"Wilgotność względna","parameters":[{"name":"Zakres","range":"(10,0 – 90,0) %"}],"technique":"Metoda pojemnościowa","techniques":["Metoda pojemnościowa"],"computed":[],"activity":"Wilgotność względna\nZakres (10,0 – 90,0) %\nMetoda pojemnościowa","reference":"EFO/PB/36/A:05.05.2025","norm_bases":["EFO/PB/36/A:05.05.2025"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe, Biogaz Wilgotność względna\nZakres (10,0 – 90,0) %\nMetoda pojemnościowa EFO/PB/36/A:05.05.2025 Gazy skladowiskowe, Biogaz Wilgotnosc wzgledna\nZakres (10,0 – 90,0) %\nMetoda pojemnosciowa EFO/PB/36/A:05.05.2025","categories":["other"],"row_index":439,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Relative humidity","parameters_en":[{"name":"Range","range":"(10,0 – 90,0) %"}],"search_en":"Landfill gases, Biogas Relative humidity Capacitive method Range EFO/PB/36/A:05.05.2025","technique_en":"Capacitive method","test_object_en":"Landfill gases, Biogas","parameters_zh":[{"name":"范围","range":"(10,0 – 90,0) %"}],"search_zh":"填埋气、沼气 相对湿度 范围 EFO/PB/36/A:05.05.2025","test_object_zh":"填埋气、沼气","methodology_zh":"相对湿度"},{"_id":"6a832b7f884ede9a1b2c5680","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gazy składowiskowe, Biogaz","methodology":"Pobieranie próbek gazów do oznaczania związków organicznych","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem rurek z węglem aktywnym","techniques":["Metoda aspiracyjna z zastosowaniem rurek z węglem aktywnym"],"computed":[],"activity":"Pobieranie próbek gazów do oznaczania związków organicznych\nMetoda aspiracyjna z zastosowaniem rurek z węglem aktywnym","reference":"EFO/PB/50/B:25.08.2025","norm_bases":["EFO/PB/50/B:25.08.2025"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe, Biogaz Pobieranie próbek gazów do oznaczania związków organicznych\nMetoda aspiracyjna z zastosowaniem rurek z węglem aktywnym EFO/PB/50/B:25.08.2025 Gazy skladowiskowe, Biogaz Pobieranie probek gazow do oznaczania zwiazkow organicznych\nMetoda aspiracyjna z zastosowaniem rurek z weglem aktywnym EFO/PB/50/B:25.08.2025","categories":["other"],"row_index":440,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas sampling for determination of organic compounds","search_en":"Landfill gases, Biogas Gas sampling for determination of organic compounds Aspiration method using activated carbon tubes EFO/PB/50/B:25.08.2025","technique_en":"Aspiration method using activated carbon tubes","test_object_en":"Landfill gases, Biogas","search_zh":"填埋气、沼气 EFO/PB/50/B:25.08.2025","test_object_zh":"填埋气、沼气"},{"_id":"6a832b7f884ede9a1b2c5681","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gazy składowiskowe, Biogaz","methodology":"Pobieranie próbek gazów","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem pipet szklanych","techniques":["Metoda aspiracyjna z zastosowaniem pipet szklanych"],"computed":[],"activity":"Pobieranie próbek gazów\nMetoda aspiracyjna z zastosowaniem pipet szklanych","reference":"EFO/PB/50/B:25.08.2025","norm_bases":["EFO/PB/50/B:25.08.2025"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe, Biogaz Pobieranie próbek gazów\nMetoda aspiracyjna z zastosowaniem pipet szklanych EFO/PB/50/B:25.08.2025 Gazy skladowiskowe, Biogaz Pobieranie probek gazow\nMetoda aspiracyjna z zastosowaniem pipet szklanych EFO/PB/50/B:25.08.2025","categories":["other"],"row_index":441,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas sampling","search_en":"Landfill gases, Biogas Gas sampling Aspiration method using glass pipettes EFO/PB/50/B:25.08.2025","technique_en":"Aspiration method using glass pipettes","test_object_en":"Landfill gases, Biogas","search_zh":"填埋气、沼气 气体采样 EFO/PB/50/B:25.08.2025","test_object_zh":"填埋气、沼气","methodology_zh":"气体采样"},{"_id":"6a832b7f884ede9a1b2c5682","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gazy składowiskowe, Biogaz","methodology":"Pobieranie próbek gazów","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem worków Tedlara","techniques":["Metoda aspiracyjna z zastosowaniem worków Tedlara"],"computed":[],"activity":"Pobieranie próbek gazów\nMetoda aspiracyjna z zastosowaniem worków Tedlara","reference":"EFO/PB/50/B:25.08.2025","norm_bases":["EFO/PB/50/B:25.08.2025"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe, Biogaz Pobieranie próbek gazów\nMetoda aspiracyjna z zastosowaniem worków Tedlara EFO/PB/50/B:25.08.2025 Gazy skladowiskowe, Biogaz Pobieranie probek gazow\nMetoda aspiracyjna z zastosowaniem workow Tedlara EFO/PB/50/B:25.08.2025","categories":["other"],"row_index":442,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas sampling","search_en":"Landfill gases, Biogas Gas sampling Aspiration method using Tedlar bags EFO/PB/50/B:25.08.2025","technique_en":"Aspiration method using Tedlar bags","test_object_en":"Landfill gases, Biogas","search_zh":"填埋气、沼气 气体采样 EFO/PB/50/B:25.08.2025","test_object_zh":"填埋气、沼气","methodology_zh":"气体采样"},{"_id":"6a832b7f884ede9a1b2c5683","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gazy składowiskowe, Biogaz","methodology":"Pobieranie próbek gazów do oznaczania: H2S, HCl, HF, SO2, H2SO4+SO3, NH3","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem roztworów pochłaniających","techniques":["Metoda aspiracyjna z zastosowaniem roztworów pochłaniających"],"computed":[],"activity":"Pobieranie próbek gazów do oznaczania: H2S, HCl, HF, SO2, H2SO4+SO3, NH3\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających","reference":"EFO/PB/50/B:25.08.2025","norm_bases":["EFO/PB/50/B:25.08.2025"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe, Biogaz Pobieranie próbek gazów do oznaczania: H2S, HCl, HF, SO2, H2SO4+SO3, NH3\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających EFO/PB/50/B:25.08.2025 Gazy skladowiskowe, Biogaz Pobieranie probek gazow do oznaczania: H2S, HCl, HF, SO2, H2SO4+SO3, NH3\nMetoda aspiracyjna z zastosowaniem roztworow pochlaniajacych EFO/PB/50/B:25.08.2025","categories":["other"],"row_index":443,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas sampling for determination of: H2S, HCl, HF, SO2, H2SO4+SO3, NH3","search_en":"Landfill gases, Biogas Gas sampling for determination of: H2S, HCl, HF, SO2, H2SO4+SO3, NH3 Aspiration method using absorbing solutions EFO/PB/50/B:25.08.2025","technique_en":"Aspiration method using absorbing solutions","test_object_en":"Landfill gases, Biogas","search_zh":"填埋气、沼气 采用吸收液的抽气法 EFO/PB/50/B:25.08.2025","technique_zh":"采用吸收液的抽气法","test_object_zh":"填埋气、沼气"},{"_id":"6a832b7f884ede9a1b2c5684","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gazy składowiskowe, Biogaz","methodology":"Emisja: H2S, HCl, HF, SO2, H2SO4+SO3, NH3 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja: H2S, HCl, HF, SO2, H2SO4+SO3, NH3 (z obliczeń)","reference":"EFO/PB/50/B:25.08.2025","norm_bases":["EFO/PB/50/B:25.08.2025"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe, Biogaz Emisja: H2S, HCl, HF, SO2, H2SO4+SO3, NH3 (z obliczeń) EFO/PB/50/B:25.08.2025 Gazy skladowiskowe, Biogaz Emisja: H2S, HCl, HF, SO2, H2SO4+SO3, NH3 (z obliczen) EFO/PB/50/B:25.08.2025","categories":["environment"],"row_index":444,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission: H2S, HCl, HF, SO2, H2SO4+SO3, NH3 (calculated)","search_en":"Landfill gases, Biogas Emission: H2S, HCl, HF, SO2, H2SO4+SO3, NH3 (calculated) EFO/PB/50/B:25.08.2025","test_object_en":"Landfill gases, Biogas","search_zh":"填埋气、沼气 EFO/PB/50/B:25.08.2025","test_object_zh":"填埋气、沼气"},{"_id":"6a832b7f884ede9a1b2c5685","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko ogólne - powietrze","methodology":"Pobieranie próbek powietrza do badań mikrobiologicznych","parameters":[],"technique":"Metoda impakcyjna (zderzeniowa)","techniques":["Metoda impakcyjna (zderzeniowa)"],"computed":[],"activity":"Pobieranie próbek powietrza do badań mikrobiologicznych\nMetoda impakcyjna (zderzeniowa)","reference":"PB/BT/15/A:02.01.2012","norm_bases":["PB/BT/15/A:02.01.2012"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - powietrze Pobieranie próbek powietrza do badań mikrobiologicznych\nMetoda impakcyjna (zderzeniowa) PB/BT/15/A:02.01.2012 Srodowisko ogolne - powietrze Pobieranie probek powietrza do badan mikrobiologicznych\nMetoda impakcyjna (zderzeniowa) PB/BT/15/A:02.01.2012","categories":["environment","microbiology"],"row_index":445,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air sampling for microbiological testing","search_en":"General environment - air Air sampling for microbiological testing Impaction method (impingement) PB/BT/15/A:02.01.2012","technique_en":"Impaction method (impingement)","test_object_en":"General environment - air","methodology_zh":"微生物检测用空气样品采集","search_zh":"一般环境 － 空气 微生物检测用空气样品采集 PB/BT/15/A:02.01.2012","test_object_zh":"一般环境 － 空气"},{"_id":"6a832b7f884ede9a1b2c5686","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-R-04031:1997 | PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","norm_bases":["PN-R-04031:1997","PN-ISO 10381-4:2007","PN-ISO 10381-5:2009"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-R-04031:1997 | PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-R-04031:1997 | PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","categories":["environment"],"row_index":446,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Soil Sampling for chemical and physical testing PN-R-04031:1997 | PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","test_object_en":"Soil","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 PN-R-04031:1997 | PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","test_object_zh":"土壤"},{"_id":"6a832b7f884ede9a1b2c5687","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Kompost, biomasa, stabilizat","methodology":"Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych","reference":"EFO/PB/09/B:05.05.2025","norm_bases":["EFO/PB/09/B:05.05.2025"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kompost, biomasa, stabilizat Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych EFO/PB/09/B:05.05.2025 Kompost, biomasa, stabilizat Pobieranie probek do badan chemicznych, fizycznych i mikrobiologicznych EFO/PB/09/B:05.05.2025","categories":["microbiology"],"row_index":447,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical and microbiological testing","search_en":"Compost, biomass, stabilised waste Sampling for chemical, physical and microbiological testing EFO/PB/09/B:05.05.2025","test_object_en":"Compost, biomass, stabilised waste","methodology_zh":"用于化学、物理与微生物检验的采样","search_zh":"堆肥、生物质、稳定化产物 用于化学、物理与微生物检验的采样 EFO/PB/09/B:05.05.2025","test_object_zh":"堆肥、生物质、稳定化产物"},{"_id":"6a832b7f884ede9a1b2c5688","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw","methodology":"Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych","reference":"PN-EN 12579:2024-09 z wyłączeniem punktu 7","norm_bases":["PN-EN 12579:2024-09 z wyłączeniem punktu 7"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych PN-EN 12579:2024-09 z wyłączeniem punktu 7 Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby (polepszacze gleby) - podloza do upraw Pobieranie probek do badan chemicznych, fizycznych i mikrobiologicznych PN-EN 12579:2024-09 z wylaczeniem punktu 7","categories":["microbiology"],"row_index":448,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical and microbiological testing","search_en":"Plant cultivation aids: - soil improvers - growing media for cultivation Sampling for chemical, physical and microbiological testing PN-EN 12579:2024-09 z wyłączeniem punktu 7","test_object_en":"Plant cultivation aids: - soil improvers - growing media for cultivation","methodology_zh":"用于化学、物理与微生物检验的采样","search_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质 用于化学、物理与微生物检验的采样 PN-EN 12579:2024-09 z wyłączeniem punktu 7","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质"},{"_id":"6a832b7f884ede9a1b2c5689","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady denne","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"ISO 5667-12:2017","norm_bases":["ISO 5667-12:2017"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady denne Pobieranie próbek do badań chemicznych i fizycznych ISO 5667-12:2017 Osady denne Pobieranie probek do badan chemicznych i fizycznych ISO 5667-12:2017","categories":["water"],"row_index":449,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Bottom sediments Sampling for chemical and physical testing ISO 5667-12:2017","test_object_en":"Bottom sediments","methodology_zh":"化学与物理检测用样品采集","search_zh":"底泥 化学与物理检测用样品采集 ISO 5667-12:2017","test_object_zh":"底泥"},{"_id":"6a832b7f884ede9a1b2c568a","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek do badań chemicznych, fizycznych i biologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych i biologicznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych, fizycznych i biologicznych PN-EN ISO 5667-13:2011 Osady sciekowe Pobieranie probek do badan chemicznych, fizycznych i biologicznych PN-EN ISO 5667-13:2011","categories":["water"],"row_index":450,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical and biological testing","search_en":"Sewage sludge Sampling for chemical, physical and biological testing PN-EN ISO 5667-13:2011","test_object_en":"Sewage sludge","search_zh":"污泥 用于化学、物理与生物检验的采样 PN-EN ISO 5667-13:2011","test_object_zh":"污泥","methodology_zh":"用于化学、物理与生物检验的采样"},{"_id":"6a832b7f884ede9a1b2c568b","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 21645:2021-09","norm_bases":["PN-EN ISO 21645:2021-09"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwa wtórne Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 21645:2021-09 Paliwa stale: stale paliwa wtorne Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 21645:2021-09","categories":["petro"],"row_index":451,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Solid fuels: solid recovered fuels Sampling for chemical and physical testing PN-EN ISO 21645:2021-09","test_object_en":"Solid fuels: solid recovered fuels","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：固体回收燃料 化学与物理检测用样品采集 PN-EN ISO 21645:2021-09","test_object_zh":"固体燃料：固体回收燃料"},{"_id":"6a832b7f884ede9a1b2c568c","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura pobranej próbki ścieków"},{"name":"Zakres","range":"(0,0 – 60,0) oC"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (0,0 – 60,0) oC\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 EFO/PB/10/A:01.05.2022","norm_bases":["PN-ISO 5667-10:2021-11 EFO/PB/10/A:01.05.2022"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (0,0 – 60,0) oC\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 EFO/PB/10/A:01.05.2022 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow\nZakres (0,0 – 60,0) oC\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 EFO/PB/10/A:01.05.2022","categories":["water"],"row_index":452,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature of the collected wastewater sample"},{"name":"Range","range":"(0,0 – 60,0) oC"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Temperature of the collected wastewater sample Range PN-ISO 5667-10:2021-11 EFO/PB/10/A:01.05.2022","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采废水样品的温度"},{"name":"范围","range":"(0,0 – 60,0) oC"}],"search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 EFO/PB/10/A:01.05.2022","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a832b7f884ede9a1b2c568d","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0,0 – 60,0) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,0 – 60,0) oC","reference":"PN-ISO 5667-5:2017-10+Ap1:2019-07 EFO/PB/10/A:01.05.2022","norm_bases":["PN-ISO 5667-5:2017-10+Ap1:2019-07 EFO/PB/10/A:01.05.2022"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,0 – 60,0) oC PN-ISO 5667-5:2017-10+Ap1:2019-07 EFO/PB/10/A:01.05.2022 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (0,0 – 60,0) oC PN-ISO 5667-5:2017-10+Ap1:2019-07 EFO/PB/10/A:01.05.2022","categories":["water"],"row_index":453,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters_en":[{"name":"Range","range":"(0,0 – 60,0) oC"}],"search_en":"Water intended for human consumption Sampling for chemical and physical testing Temperature of the water sample taken Range PN-ISO 5667-5:2017-10+Ap1:2019-07 EFO/PB/10/A:01.05.2022","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,0 – 60,0) oC"}],"search_zh":"生活饮用水 化学和物理检测采样 所采水样的温度 范围 PN-ISO 5667-5:2017-10+Ap1:2019-07 EFO/PB/10/A:01.05.2022","test_object_zh":"生活饮用水","methodology_zh":"化学和物理检测采样 所采水样的温度"},{"_id":"6a832b7f884ede9a1b2c568e","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda, Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":454,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water, Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007","test_object_en":"Water, Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"水、生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"水、生活饮用水"},{"_id":"6a832b7f884ede9a1b2c568f","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda na plywalniach Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":455,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Swimming pool water Sampling for microbiological testing PN-EN ISO 19458:2007","test_object_en":"Swimming pool water","methodology_zh":"微生物检测用样品采集","search_zh":"游泳池水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"游泳池水"},{"_id":"6a832b7f884ede9a1b2c5690","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10+Ap1:2019-07 EFO/PB/34/A:17.09.2024","norm_bases":["PN-ISO 5667-5:2017-10+Ap1:2019-07 EFO/PB/34/A:17.09.2024"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10+Ap1:2019-07 EFO/PB/34/A:17.09.2024 Woda na plywalniach Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10+Ap1:2019-07 EFO/PB/34/A:17.09.2024","categories":["water"],"row_index":456,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Swimming pool water Sampling for chemical and physical testing PN-ISO 5667-5:2017-10+Ap1:2019-07 EFO/PB/34/A:17.09.2024","test_object_en":"Swimming pool water","methodology_zh":"化学与物理检测用样品采集","search_zh":"游泳池水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10+Ap1:2019-07 EFO/PB/34/A:17.09.2024","test_object_zh":"游泳池水"},{"_id":"6a832b7f884ede9a1b2c5691","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0,0 – 60,0) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura pobranej próbki wody\nZakres (0,0 – 60,0) oC","reference":"EFO/PB/10/A:01.05.2022","norm_bases":["EFO/PB/10/A:01.05.2022"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Temperatura pobranej próbki wody\nZakres (0,0 – 60,0) oC EFO/PB/10/A:01.05.2022 Woda na plywalniach Temperatura pobranej probki wody\nZakres (0,0 – 60,0) oC EFO/PB/10/A:01.05.2022","categories":["water"],"row_index":457,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of the collected water sample","parameters_en":[{"name":"Range","range":"(0,0 – 60,0) oC"}],"search_en":"Swimming pool water Temperature of the collected water sample Range EFO/PB/10/A:01.05.2022","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(0,0 – 60,0) oC"}],"search_zh":"游泳池水 所采水样的温度 范围 EFO/PB/10/A:01.05.2022","test_object_zh":"游泳池水","methodology_zh":"所采水样的温度"},{"_id":"6a832b7f884ede9a1b2c5692","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda na plywalniach pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":458,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Swimming pool water pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Swimming pool water","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"游泳池水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"游泳池水"},{"_id":"6a832b7f884ede9a1b2c5693","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Potencjał utleniająco-redukujący (potencjał redoks) wzgl. Ag/AgCl 3,5 mol/l KCL","parameters":[{"name":"Zakres","range":"(0 – 1000) mV"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Potencjał utleniająco-redukujący (potencjał redoks) wzgl. Ag/AgCl 3,5 mol/l KCL\nZakres (0 – 1000) mV\nMetoda potencjometryczna","reference":"PB/FCH/38/D:03.06.2016","norm_bases":["PB/FCH/38/D:03.06.2016"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Potencjał utleniająco-redukujący (potencjał redoks) wzgl. Ag/AgCl 3,5 mol/l KCL\nZakres (0 – 1000) mV\nMetoda potencjometryczna PB/FCH/38/D:03.06.2016 Woda na plywalniach Potencjal utleniajaco-redukujacy (potencjal redoks) wzgl. Ag/AgCl 3,5 mol/l KCL\nZakres (0 – 1000) mV\nMetoda potencjometryczna PB/FCH/38/D:03.06.2016","categories":["water"],"row_index":459,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation-reduction potential (redox potential) ref. to Ag/AgCl 3,5 mol/l KCL","parameters_en":[{"name":"Range","range":"(0 – 1000) mV"}],"search_en":"Swimming pool water Oxidation-reduction potential (redox potential) ref. to Ag/AgCl 3,5 mol/l KCL Potentiometric method Range PB/FCH/38/D:03.06.2016","technique_en":"Potentiometric method","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(0 – 1000) mV"}],"search_zh":"游泳池水 电位法 范围 PB/FCH/38/D:03.06.2016","technique_zh":"电位法","test_object_zh":"游泳池水"},{"_id":"6a832b7f884ede9a1b2c5694","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,02 – 8,0) mg/l"},{"name":"Stężenie chloru ogólnego/całkowitego"},{"name":"Zakres","range":"(0,02 – 8,0) mg/l"},{"name":"Stężenie chloru związanego (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloru wolnego\nZakres:\nZakres (0,02 – 8,0) mg/l\nStężenie chloru ogólnego/całkowitego\nZakres (0,02 – 8,0) mg/l\nStężenie chloru związanego (z obliczeń)","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie chloru wolnego\nZakres:\nZakres (0,02 – 8,0) mg/l\nStężenie chloru ogólnego/całkowitego\nZakres (0,02 – 8,0) mg/l\nStężenie chloru związanego (z obliczeń) PN-EN ISO 7393-2:2018-04 Woda na plywalniach Stezenie chloru wolnego\nZakres:\nZakres (0,02 – 8,0) mg/l\nStezenie chloru ogolnego/calkowitego\nZakres (0,02 – 8,0) mg/l\nStezenie chloru zwiazanego (z obliczen) PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":460,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,02 – 8,0) mg/l"},{"name":"Total chlorine concentration"},{"name":"Range","range":"(0,02 – 8,0) mg/l"},{"name":"Combined chlorine concentration (calculated)"}],"search_en":"Swimming pool water Free chlorine concentration Range Total chlorine concentration Range Combined chlorine concentration (calculated) PN-EN ISO 7393-2:2018-04","test_object_en":"Swimming pool water","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 8,0) mg/l"},{"name":"总氯浓度"},{"name":"范围","range":"(0,02 – 8,0) mg/l"},{"name":"化合氯浓度（计算值）"}],"search_zh":"游泳池水 游离氯浓度 范围 总氯浓度 范围 化合氯浓度（计算值） PN-EN ISO 7393-2:2018-04","test_object_zh":"游泳池水"},{"_id":"6a832b7f884ede9a1b2c5695","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie ozonu","parameters":[{"name":"Zakres","range":"(0,04 – 0,50) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie ozonu\nZakres (0,04 – 0,50) mg/l\nMetoda kolorymetryczna","reference":"E F O/PB/22/A:23.06.2023","norm_bases":["E F O/PB/22/A:23.06.2023"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie ozonu\nZakres (0,04 – 0,50) mg/l\nMetoda kolorymetryczna E F O/PB/22/A:23.06.2023 Woda na plywalniach Stezenie ozonu\nZakres (0,04 – 0,50) mg/l\nMetoda kolorymetryczna E F O/PB/22/A:23.06.2023","categories":["water"],"row_index":461,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ozone concentration","parameters_en":[{"name":"Range","range":"(0,04 – 0,50) mg/l"}],"search_en":"Swimming pool water Ozone concentration Colorimetric method Range E F O/PB/22/A:23.06.2023","technique_en":"Colorimetric method","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(0,04 – 0,50) mg/l"}],"search_zh":"游泳池水 臭氧浓度 比色法 范围 E F O/PB/22/A:23.06.2023","technique_zh":"比色法","test_object_zh":"游泳池水","methodology_zh":"臭氧浓度"},{"_id":"6a832b7f884ede9a1b2c5696","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda podziemna","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0,0 – 35,0) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,0 – 35,0) oC","reference":"PN-ISO 5667-11:2017-10 EFO/PB/10/A:01.05.2022","norm_bases":["PN-ISO 5667-11:2017-10 EFO/PB/10/A:01.05.2022"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda podziemna Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,0 – 35,0) oC PN-ISO 5667-11:2017-10 EFO/PB/10/A:01.05.2022 Woda podziemna Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (0,0 – 35,0) oC PN-ISO 5667-11:2017-10 EFO/PB/10/A:01.05.2022","categories":["water"],"row_index":462,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters_en":[{"name":"Range","range":"(0,0 – 35,0) oC"}],"search_en":"Groundwater Sampling for chemical and physical testing Temperature of the water sample taken Range PN-ISO 5667-11:2017-10 EFO/PB/10/A:01.05.2022","test_object_en":"Groundwater","parameters_zh":[{"name":"范围","range":"(0,0 – 35,0) oC"}],"search_zh":"地下水 化学和物理检测采样 所采水样的温度 范围 PN-ISO 5667-11:2017-10 EFO/PB/10/A:01.05.2022","methodology_zh":"化学和物理检测采样 所采水样的温度","test_object_zh":"地下水"},{"_id":"6a832b7f884ede9a1b2c5697","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda podziemna","methodology":"Poziom lustra wody (T)","parameters":[{"name":"Zakres","range":"(0- 80) m"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom lustra wody (T)\nZakres (0- 80) m","reference":"EFO/PB/23/A:10.07.2023","norm_bases":["EFO/PB/23/A:10.07.2023"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda podziemna Poziom lustra wody (T)\nZakres (0- 80) m EFO/PB/23/A:10.07.2023 Woda podziemna Poziom lustra wody (T)\nZakres (0- 80) m EFO/PB/23/A:10.07.2023","categories":["water"],"row_index":463,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water table level (T)","parameters_en":[{"name":"Range","range":"(0- 80) m"}],"search_en":"Groundwater Water table level (T) Range EFO/PB/23/A:10.07.2023","test_object_en":"Groundwater","parameters_zh":[{"name":"范围","range":"(0- 80) m"}],"search_zh":"地下水 范围 EFO/PB/23/A:10.07.2023","test_object_zh":"地下水"},{"_id":"6a832b7f884ede9a1b2c5698","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda powierzchniowa","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0,0 – 35,0) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,0 – 35,0) oC","reference":"PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-4:2017-10 EFO/PB/10/A:01.05.2022","norm_bases":["PN-EN ISO 5667-6:2016-12","PN-ISO 5667-4:2017-10 EFO/PB/10/A:01.05.2022"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda powierzchniowa Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,0 – 35,0) oC PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-4:2017-10 EFO/PB/10/A:01.05.2022 Woda powierzchniowa Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (0,0 – 35,0) oC PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-4:2017-10 EFO/PB/10/A:01.05.2022","categories":["water"],"row_index":464,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters_en":[{"name":"Range","range":"(0,0 – 35,0) oC"}],"search_en":"Surface water Sampling for chemical and physical testing Temperature of the water sample taken Range PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-4:2017-10 EFO/PB/10/A:01.05.2022","test_object_en":"Surface water","parameters_zh":[{"name":"范围","range":"(0,0 – 35,0) oC"}],"search_zh":"地表水 化学和物理检测采样 所采水样的温度 范围 PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-4:2017-10 EFO/PB/10/A:01.05.2022","methodology_zh":"化学和物理检测采样 所采水样的温度","test_object_zh":"地表水"},{"_id":"6a832b7f884ede9a1b2c5699","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Wody opadowe i roztopowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe i roztopowe Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-10:2021-11 Wody opadowe i roztopowe Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-10:2021-11","categories":["water"],"row_index":465,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Rainwater and snowmelt water Sampling for chemical and physical testing PN-ISO 5667-10:2021-11","test_object_en":"Rainwater and snowmelt water","methodology_zh":"化学与物理检测用样品采集","search_zh":"雨水与融雪水 化学与物理检测用样品采集 PN-ISO 5667-10:2021-11","test_object_zh":"雨水与融雪水"},{"_id":"6a832b7f884ede9a1b2c569a","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"OdpadyDAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) z wyłączeniem odpadów zwierzęcych - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"EFO/PB/09/B:05.05.2025","norm_bases":["EFO/PB/09/B:05.05.2025"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"OdpadyDAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne i z przetwórstwa żywności (IV) z wyłączeniem odpadów zwierzęcych - Szlamy i odpady płynne (V) - Odpady z przetwarzania odpadów (VI) - Osady z procesów przemysłowych (VII) - Osady zawierające związki ropopochodne (VIII) - Osady ściekowe (IX) - Odpady z oczyszczania gazów odlotowych (X) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. Pobieranie próbek do badań chemicznych i fizycznych EFO/PB/09/B:05.05.2025 OdpadyDAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne i z przetworstwa zywnosci (IV) z wylaczeniem odpadow zwierzecych - Szlamy i odpady plynne (V) - Odpady z przetwarzania odpadow (VI) - Osady z procesow przemyslowych (VII) - Osady zawierajace zwiazki ropopochodne (VIII) - Osady sciekowe (IX) - Odpady z oczyszczania gazow odlotowych (X) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Odpady szklane (XXIII) - Papier i tektura (XXIV) - Tworzywa sztuczne (XXV) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11. Pobieranie probek do badan chemicznych i fizycznych EFO/PB/09/B:05.05.2025","categories":["water","environment","food","materials","construction"],"row_index":466,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Sampling for chemical and physical testing EFO/PB/09/B:05.05.2025","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 EFO/PB/09/B:05.05.2025"},{"_id":"6a832b7f884ede9a1b2c569b","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) - Inne odpady komunalne, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11.","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 21645:2021-09","norm_bases":["PN-EN ISO 21645:2021-09"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady DAB-11: - Odpady z przetwarzania odpadów (VI) - Inne odpady komunalne, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII); DAB-11) Kody odpadów według rozporządzenia Ministra Klimatu w sprawie katalogu odpadów dla grupy walidacyjnej podano w Załączniku nr 1 do DAB-11. Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 21645:2021-09 Odpady DAB-11: - Odpady z przetwarzania odpadow (VI) - Inne odpady komunalne, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII); DAB-11) Kody odpadow wedlug rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow dla grupy walidacyjnej podano w Zalaczniku nr 1 do DAB-11. Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 21645:2021-09","categories":["environment","water"],"row_index":467,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Sampling for chemical and physical testing PN-EN ISO 21645:2021-09","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PN-EN ISO 21645:2021-09"},{"_id":"6a832b7f884ede9a1b2c569c","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5 – 20,0) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 – 20,0) mg/l O2\nMetoda optyczna","reference":"ISO 17289:2014","norm_bases":["ISO 17289:2014"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie tlenu rozpuszczonego\nZakres (0,5 – 20,0) mg/l O2\nMetoda optyczna ISO 17289:2014 Woda Stezenie tlenu rozpuszczonego\nZakres (0,5 – 20,0) mg/l O2\nMetoda optyczna ISO 17289:2014","categories":["water"],"row_index":468,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 20,0) mg/l O2"}],"search_en":"Water Dissolved oxygen concentration Optical method Range ISO 17289:2014","technique_en":"Optical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,5 – 20,0) mg/l O2"}],"search_zh":"水 溶解氧浓度 光学法 范围 ISO 17289:2014","technique_zh":"光学法","test_object_zh":"水","methodology_zh":"溶解氧浓度"},{"_id":"6a832b7f884ede9a1b2c569d","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,2 – 800) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,2 – 800) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,2 – 800) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,2 – 800) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":469,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,2 – 800) NTU"}],"search_en":"Water, Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,2 – 800) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a832b7f884ede9a1b2c569e","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Potencjał utleniająco-redukujący (potencjał redoks)","parameters":[{"name":"Zakres","range":"(-150 – 1000) mV"}],"technique":"Metoda potencjometryczna; Metoda potencjometryczna","techniques":["Metoda potencjometryczna","Metoda potencjometryczna"],"computed":[],"activity":"Potencjał utleniająco-redukujący (potencjał redoks)\nZakres (-150 – 1000) mV\nMetoda potencjometryczna; Metoda potencjometryczna","reference":"PB/FCH/38/D:03.06.2016","norm_bases":["PB/FCH/38/D:03.06.2016"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Potencjał utleniająco-redukujący (potencjał redoks)\nZakres (-150 – 1000) mV\nMetoda potencjometryczna; Metoda potencjometryczna PB/FCH/38/D:03.06.2016 Woda, Woda do spozycia przez ludzi Potencjal utleniajaco-redukujacy (potencjal redoks)\nZakres (-150 – 1000) mV\nMetoda potencjometryczna; Metoda potencjometryczna PB/FCH/38/D:03.06.2016","categories":["water"],"row_index":470,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation-reduction potential (redox potential)","parameters_en":[{"name":"Range","range":"(-150 – 1000) mV"}],"search_en":"Water, Water intended for human consumption Oxidation-reduction potential (redox potential) Potentiometric method; Potentiometric method Range PB/FCH/38/D:03.06.2016","technique_en":"Potentiometric method; Potentiometric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(-150 – 1000) mV"}],"search_zh":"水、生活饮用水 范围 PB/FCH/38/D:03.06.2016","test_object_zh":"水、生活饮用水"},{"_id":"6a832b7f884ede9a1b2c569f","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie ozonu","parameters":[{"name":"Zakres","range":"(0,04 – 0,50) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie ozonu\nZakres (0,04 – 0,50) mg/l\nMetoda kolorymetryczna","reference":"E F O / P B / 2 2 / A : 2 3 .06.2023","norm_bases":["E F O / P B / 2 2 / A : 2 3 .06.2023"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie ozonu\nZakres (0,04 – 0,50) mg/l\nMetoda kolorymetryczna E F O / P B / 2 2 / A : 2 3 .06.2023 Woda, Woda do spozycia przez ludzi Stezenie ozonu\nZakres (0,04 – 0,50) mg/l\nMetoda kolorymetryczna E F O / P B / 2 2 / A : 2 3 .06.2023","categories":["water"],"row_index":471,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ozone concentration","parameters_en":[{"name":"Range","range":"(0,04 – 0,50) mg/l"}],"search_en":"Water, Water intended for human consumption Ozone concentration Colorimetric method Range E F O / P B / 2 2 / A : 2 3 .06.2023","technique_en":"Colorimetric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,04 – 0,50) mg/l"}],"search_zh":"水、生活饮用水 臭氧浓度 比色法 范围 E F O / P B / 2 2 / A : 2 3 .06.2023","technique_zh":"比色法","test_object_zh":"水、生活饮用水","methodology_zh":"臭氧浓度"},{"_id":"6a832b7f884ede9a1b2c56a0","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5 – 20,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 – 20,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie tlenu rozpuszczonego\nZakres (0,5 – 20,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda, Woda do spozycia przez ludzi Stezenie tlenu rozpuszczonego\nZakres (0,5 – 20,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":472,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 20,0) mg/l O2"}],"search_en":"Water, Water intended for human consumption Dissolved oxygen concentration Electrochemical method Range PN-EN ISO 5814:2013-04","technique_en":"Electrochemical method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,5 – 20,0) mg/l O2"}],"search_zh":"水、生活饮用水 溶解氧浓度 电化学法 范围 PN-EN ISO 5814:2013-04","technique_zh":"电化学法","test_object_zh":"水、生活饮用水","methodology_zh":"溶解氧浓度"},{"_id":"6a832b7f884ede9a1b2c56a1","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi, Scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":473,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Water, Water intended for human consumption, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、生活饮用水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c56a2","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 – 99990) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 99990) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Przewodność elektryczna właściwa\nZakres (10 – 99990) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi, Scieki Przewodnosc elektryczna wlasciwa\nZakres (10 – 99990) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":474,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10 – 99990) μS/cm"}],"search_en":"Water, Water intended for human consumption, Wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 99990) μS/cm"}],"search_zh":"水、生活饮用水、废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a832b7f884ede9a1b2c56a3","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki oczyszczone","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,02 – 8,0) mg/l"},{"name":"Stężenie chloru ogólnego/całkowitego"},{"name":"Zakres","range":"(0,02 – 8,0) mg/l"},{"name":"Stężenie całkowitego chloru pozostałego"},{"name":"Zakres","range":"(0,03 – 12,0) mg/l HOCl"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres:\nZakres (0,02 – 8,0) mg/l\nStężenie chloru ogólnego/całkowitego\nZakres (0,02 – 8,0) mg/l\nStężenie całkowitego chloru pozostałego\nZakres (0,03 – 12,0) mg/l HOCl\nMetoda kolorymetryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki oczyszczone Stężenie chloru wolnego\nZakres:\nZakres (0,02 – 8,0) mg/l\nStężenie chloru ogólnego/całkowitego\nZakres (0,02 – 8,0) mg/l\nStężenie całkowitego chloru pozostałego\nZakres (0,03 – 12,0) mg/l HOCl\nMetoda kolorymetryczna PN-EN ISO 7393-2:2018-04 Woda, Woda do spozycia przez ludzi, Scieki oczyszczone Stezenie chloru wolnego\nZakres:\nZakres (0,02 – 8,0) mg/l\nStezenie chloru ogolnego/calkowitego\nZakres (0,02 – 8,0) mg/l\nStezenie calkowitego chloru pozostalego\nZakres (0,03 – 12,0) mg/l HOCl\nMetoda kolorymetryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":475,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,02 – 8,0) mg/l"},{"name":"Total chlorine concentration"},{"name":"Range","range":"(0,02 – 8,0) mg/l"},{"name":"Total residual chlorine concentration"},{"name":"Range","range":"(0,03 – 12,0) mg/l HOCl"}],"search_en":"Water, Water intended for human consumption, Treated wastewater Free chlorine concentration Colorimetric method Range Total chlorine concentration Range Total residual chlorine concentration Range PN-EN ISO 7393-2:2018-04","technique_en":"Colorimetric method","test_object_en":"Water, Water intended for human consumption, Treated wastewater","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 8,0) mg/l"},{"name":"总氯浓度"},{"name":"范围","range":"(0,02 – 8,0) mg/l"},{"name":"Stężenie całkowitego chloru pozostałego"},{"name":"范围","range":"(0,03 – 12,0) mg/l HOCl"}],"search_zh":"水、生活饮用水、处理后废水 游离氯浓度 比色法 范围 总氯浓度 范围 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"比色法","test_object_zh":"水、生活饮用水、处理后废水"},{"_id":"6a832b7f884ede9a1b2c56a4","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki oczyszczone","methodology":"Stężenie chloramin (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloramin (z obliczeń)","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki oczyszczone Stężenie chloramin (z obliczeń) PN-EN ISO 7393-2:2018-04 Woda, Woda do spozycia przez ludzi, Scieki oczyszczone Stezenie chloramin (z obliczen) PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":476,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloramine concentration (calculated)","search_en":"Water, Water intended for human consumption, Treated wastewater Chloramine concentration (calculated) PN-EN ISO 7393-2:2018-04","test_object_en":"Water, Water intended for human consumption, Treated wastewater","search_zh":"水、生活饮用水、处理后废水 氯胺浓度（由计算得出） PN-EN ISO 7393-2:2018-04","test_object_zh":"水、生活饮用水、处理后废水","methodology_zh":"氯胺浓度（由计算得出）"},{"_id":"6a832b7f884ede9a1b2c56a5","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki oczyszczone","methodology":"Stężenie chloru związanego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloru związanego (z obliczeń)","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Pracownia Badań Terenowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki oczyszczone Stężenie chloru związanego (z obliczeń) PN-EN ISO 7393-2:2018-04 Woda, Woda do spozycia przez ludzi, Scieki oczyszczone Stezenie chloru zwiazanego (z obliczen) PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":477,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Combined chlorine concentration (calculated)","search_en":"Water, Water intended for human consumption, Treated wastewater Combined chlorine concentration (calculated) PN-EN ISO 7393-2:2018-04","test_object_en":"Water, Water intended for human consumption, Treated wastewater","methodology_zh":"化合氯浓度（计算值）","search_zh":"水、生活饮用水、处理后废水 化合氯浓度（计算值） PN-EN ISO 7393-2:2018-04","test_object_zh":"水、生活饮用水、处理后废水"},{"_id":"6a832b7f884ede9a1b2c56a6","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temp. 36 ̊C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36 ̊C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 36 ̊C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 36 C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":478,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total count of microorganisms at 36 ̊C","search_en":"Water, Water intended for human consumption Total count of microorganisms at 36 ̊C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a832b7f884ede9a1b2c56a7","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temp. 22 ̊C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22 ̊C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 22 ̊C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 22 C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":479,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total count of microorganisms at 22 ̊C","search_en":"Water, Water intended for human consumption Total count of microorganisms at 22 ̊C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a832b7f884ede9a1b2c56a8","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temp. 37 ̊C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 37 ̊C\nMetoda płytkowa (posiew wgłębny)","reference":"PB/BB/32/A:28.10.2019","norm_bases":["PB/BB/32/A:28.10.2019"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 37 ̊C\nMetoda płytkowa (posiew wgłębny) PB/BB/32/A:28.10.2019 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 37 C\nMetoda plytkowa (posiew wglebny) PB/BB/32/A:28.10.2019","categories":["water"],"row_index":480,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total count of microorganisms at 37 ̊C","search_en":"Water, Water intended for human consumption Total count of microorganisms at 37 ̊C Plate method (pour plate) PB/BB/32/A:28.10.2019","technique_en":"Plate method (pour plate)","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 平板法（倾注培养） PB/BB/32/A:28.10.2019","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a832b7f884ede9a1b2c56a9","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba bakterii z grupy coli","parameters":[],"technique":"Metoda NPL, Colilert 18","techniques":["Metoda NPL, Colilert 18"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii z grupy coli\nMetoda NPL, Colilert 18","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii z grupy coli\nMetoda NPL, Colilert 18 PN-EN ISO 9308-2:2014-06 Woda, Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii z grupy coli\nMetoda NPL, Colilert 18 PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":481,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of coliform bacteria","search_en":"Water, Water intended for human consumption Most probable number of coliform bacteria MPN method, Colilert 18 PN-EN ISO 9308-2:2014-06","technique_en":"MPN method, Colilert 18","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 大肠菌群最可能数 PN-EN ISO 9308-2:2014-06","test_object_zh":"水、生活饮用水","methodology_zh":"大肠菌群最可能数"},{"_id":"6a832b7f884ede9a1b2c56aa","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","parameters":[],"technique":"Metoda NPL, Colilert 18","techniques":["Metoda NPL, Colilert 18"],"computed":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL, Colilert 18","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL, Colilert 18 PN-EN ISO 9308-2:2014-06 Woda, Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL, Colilert 18 PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":482,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number, Escherichia coli","search_en":"Water, Water intended for human consumption Most probable number, Escherichia coli MPN method, Colilert 18 PN-EN ISO 9308-2:2014-06","technique_en":"MPN method, Colilert 18","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）最可能数（MPN） PN-EN ISO 9308-2:2014-06","test_object_zh":"水、生活饮用水"},{"_id":"6a832b7f884ede9a1b2c56ab","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PB/BB/3/G:06.09.2018","norm_bases":["PB/BB/3/G:06.09.2018"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PB/BB/3/G:06.09.2018 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PB/BB/3/G:06.09.2018","categories":["water","microbiology"],"row_index":483,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PB/BB/3/G:06.09.2018","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PB/BB/3/G:06.09.2018","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a832b7f884ede9a1b2c56ac","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli typu kałowego","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli typu kałowego\nMetoda filtracji membranowej","reference":"PB/BB/3/G:06.09.2018","norm_bases":["PB/BB/3/G:06.09.2018"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli typu kałowego\nMetoda filtracji membranowej PB/BB/3/G:06.09.2018 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli typu kalowego\nMetoda filtracji membranowej PB/BB/3/G:06.09.2018","categories":["water","microbiology"],"row_index":484,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Faecal coliform bacteria count","search_en":"Water, Water intended for human consumption Faecal coliform bacteria count Membrane filtration method PB/BB/3/G:06.09.2018","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 粪大肠菌群数 膜过滤法 PB/BB/3/G:06.09.2018","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"粪大肠菌群数"},{"_id":"6a832b7f884ede9a1b2c56ad","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PB/BB/3/G:06.09.2018","norm_bases":["PB/BB/3/G:06.09.2018"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PB/BB/3/G:06.09.2018 Woda, Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PB/BB/3/G:06.09.2018","categories":["water","microbiology"],"row_index":485,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water, Water intended for human consumption Escherichia coli count Membrane filtration method PB/BB/3/G:06.09.2018","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PB/BB/3/G:06.09.2018","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a832b7f884ede9a1b2c56ae","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":486,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a832b7f884ede9a1b2c56af","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":487,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water, Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a832b7f884ede9a1b2c56b0","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba Clostridium perfringens (łącznie ze sporami)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda, Woda do spozycia przez ludzi Liczba Clostridium perfringens (lacznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":488,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Clostridium perfringens count (including spores)","search_en":"Water, Water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 产气荚膜梭菌计数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"产气荚膜梭菌计数（含芽孢）"},{"_id":"6a832b7f884ede9a1b2c56b1","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba clostridiów redukujących siarczyny","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba clostridiów redukujących siarczyny\nMetoda filtracji membranowej","reference":"PN-EN 26461-2:2001","norm_bases":["PN-EN 26461-2:2001"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba clostridiów redukujących siarczyny\nMetoda filtracji membranowej PN-EN 26461-2:2001 Woda, Woda do spozycia przez ludzi Liczba clostridiow redukujacych siarczyny\nMetoda filtracji membranowej PN-EN 26461-2:2001","categories":["water"],"row_index":489,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of sulphite-reducing clostridia","search_en":"Water, Water intended for human consumption Count of sulphite-reducing clostridia Membrane filtration method PN-EN 26461-2:2001","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 膜过滤法 PN-EN 26461-2:2001","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a832b7f884ede9a1b2c56b2","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba Colifagów somatycznych","parameters":[],"technique":"Metoda płytkowa","techniques":["Metoda płytkowa"],"computed":[],"activity":"Liczba Colifagów somatycznych\nMetoda płytkowa","reference":"PN-EN ISO 10705-2:2005","norm_bases":["PN-EN ISO 10705-2:2005"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Colifagów somatycznych\nMetoda płytkowa PN-EN ISO 10705-2:2005 Woda, Woda do spozycia przez ludzi Liczba Colifagow somatycznych\nMetoda plytkowa PN-EN ISO 10705-2:2005","categories":["water"],"row_index":490,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of somatic coliphages","search_en":"Water, Water intended for human consumption Count of somatic coliphages Plate method PN-EN ISO 10705-2:2005","technique_en":"Plate method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 平板法 PN-EN ISO 10705-2:2005","technique_zh":"平板法","test_object_zh":"水、生活饮用水"},{"_id":"6a832b7f884ede9a1b2c56b3","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":491,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water, Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"粪肠球菌计数","search_zh":"水、生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a832b7f884ede9a1b2c56b4","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba gronkowców koagulazo","parameters":[{"name":"dodatnich"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba gronkowców koagulazo\ndodatnich\nMetoda filtracji membranowej","reference":"PB/BB/11/A:04.07.2011","norm_bases":["PB/BB/11/A:04.07.2011"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba gronkowców koagulazo\ndodatnich\nMetoda filtracji membranowej PB/BB/11/A:04.07.2011 Woda, Woda do spozycia przez ludzi Liczba gronkowcow koagulazo\ndodatnich\nMetoda filtracji membranowej PB/BB/11/A:04.07.2011","categories":["water"],"row_index":492,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of coagulase staphylococci","parameters_en":[{"name":"positive"}],"search_en":"Water, Water intended for human consumption Count of coagulase staphylococci Membrane filtration method positive PB/BB/11/A:04.07.2011","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 膜过滤法 PB/BB/11/A:04.07.2011","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a832b7f884ede9a1b2c56b5","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba Legionella sp.","parameters":[{"name":"Matryca A Procedura 5 (pożywka BCYE) Procedura 7 (pożywka MWY)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Legionella sp.\nMatryca A Procedura 5 (pożywka BCYE) Procedura 7 (pożywka MWY)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08","norm_bases":["PN-EN ISO 11731:2017-08"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Legionella sp.\nMatryca A Procedura 5 (pożywka BCYE) Procedura 7 (pożywka MWY)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 Woda, Woda do spozycia przez ludzi Liczba Legionella sp.\nMatryca A Procedura 5 (pozywka BCYE) Procedura 7 (pozywka MWY)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08","categories":["microbiology","water"],"row_index":493,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Legionella sp. count","parameters_en":[{"name":"Matrix A Procedure 5 (medium BCYE) Procedure 7 (medium MWY)"}],"search_en":"Water, Water intended for human consumption Legionella sp. count Membrane filtration method Matrix A Procedure 5 (medium BCYE) Procedure 7 (medium MWY) PN-EN ISO 11731:2017-08","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 军团菌属计数 膜过滤法 PN-EN ISO 11731:2017-08","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"军团菌属计数"},{"_id":"6a832b7f884ede9a1b2c56b6","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba Legionella sp.","parameters":[{"name":"Matryca A Procedura 1 (pożywka BCYE i BCYE+AB)"}],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba Legionella sp.\nMatryca A Procedura 1 (pożywka BCYE i BCYE+AB)\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 11731:2017-08","norm_bases":["PN-EN ISO 11731:2017-08"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Legionella sp.\nMatryca A Procedura 1 (pożywka BCYE i BCYE+AB)\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 11731:2017-08 Woda, Woda do spozycia przez ludzi Liczba Legionella sp.\nMatryca A Procedura 1 (pozywka BCYE i BCYE+AB)\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 11731:2017-08","categories":["microbiology","water"],"row_index":494,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Legionella sp. count","parameters_en":[{"name":"Matrix A Procedure 1 (medium BCYE and BCYE+AB)"}],"search_en":"Water, Water intended for human consumption Legionella sp. count Plate method (spread plate) Matrix A Procedure 1 (medium BCYE and BCYE+AB) PN-EN ISO 11731:2017-08","technique_en":"Plate method (spread plate)","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 军团菌属计数 平板法（表面涂布） PN-EN ISO 11731:2017-08","technique_zh":"平板法（表面涂布）","test_object_zh":"水、生活饮用水","methodology_zh":"军团菌属计数"},{"_id":"6a832b7f884ede9a1b2c56b7","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda, Woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":495,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water, Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"铜绿假单胞菌计数","search_zh":"水、生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a832b7f884ede9a1b2c56b8","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa smaku TFN","parameters":[{"name":"Zakres","range":"(1 – 16)"}],"technique":"Metoda parzysta uproszczona i pełna wyboru niewymuszonego","techniques":["Metoda parzysta uproszczona i pełna wyboru niewymuszonego"],"computed":[],"activity":"Liczba progowa smaku TFN\nZakres (1 – 16)\nMetoda parzysta uproszczona i pełna wyboru niewymuszonego","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa smaku TFN\nZakres (1 – 16)\nMetoda parzysta uproszczona i pełna wyboru niewymuszonego PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa smaku TFN\nZakres (1 – 16)\nMetoda parzysta uproszczona i pelna wyboru niewymuszonego PN-EN 1622:2006","categories":["water"],"row_index":496,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Taste threshold number TFN","parameters_en":[{"name":"Range","range":"(1 – 16)"}],"search_en":"Water intended for human consumption Taste threshold number TFN Simplified and full paired method with non-forced choice Range PN-EN 1622:2006","technique_en":"Simplified and full paired method with non-forced choice","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(1 – 16)"}],"search_zh":"生活饮用水 味阈值 TFN 成对简化法与完全法，非强制选择 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","methodology_zh":"味阈值 TFN","technique_zh":"成对简化法与完全法，非强制选择"},{"_id":"6a832b7f884ede9a1b2c56b9","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba progowa zapachu TON","parameters":[{"name":"Zakres","range":"(1 – 16)"}],"technique":"Metoda parzysta uproszczona i pełna wyboru niewymuszonego","techniques":["Metoda parzysta uproszczona i pełna wyboru niewymuszonego"],"computed":[],"activity":"Liczba progowa zapachu TON\nZakres (1 – 16)\nMetoda parzysta uproszczona i pełna wyboru niewymuszonego","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba progowa zapachu TON\nZakres (1 – 16)\nMetoda parzysta uproszczona i pełna wyboru niewymuszonego PN-EN 1622:2006 Woda, Woda do spozycia przez ludzi Liczba progowa zapachu TON\nZakres (1 – 16)\nMetoda parzysta uproszczona i pelna wyboru niewymuszonego PN-EN 1622:2006","categories":["water"],"row_index":497,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Odour threshold number TON","parameters_en":[{"name":"Range","range":"(1 – 16)"}],"search_en":"Water, Water intended for human consumption Odour threshold number TON Simplified and full paired method with non-forced choice Range PN-EN 1622:2006","technique_en":"Simplified and full paired method with non-forced choice","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(1 – 16)"}],"search_zh":"水、生活饮用水 嗅阈值 TON 成对简化法与完全法，非强制选择 范围 PN-EN 1622:2006","test_object_zh":"水、生活饮用水","methodology_zh":"嗅阈值 TON","technique_zh":"成对简化法与完全法，非强制选择"},{"_id":"6a832b7f884ede9a1b2c56ba","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady kod: 19 08 02; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Obecność Salmonella spp.w 25g","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella spp.w 25g\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04+A1:2020-09","norm_bases":["PN-EN ISO 6579-1:2017-04+A1:2020-09"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady kod: 19 08 02; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Obecność Salmonella spp.w 25g\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04+A1:2020-09 Odpady kod: 19 08 02; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Obecnosc Salmonella spp.w 25g\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04+A1:2020-09","categories":["environment","microbiology"],"row_index":498,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp.in 25g","search_en":"Presence of Salmonella spp.in 25g Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04+A1:2020-09","technique_en":"Culture method with biochemical and serological confirmation","search_zh":"培养法结合生化与血清学确认 PN-EN ISO 6579-1:2017-04+A1:2020-09","technique_zh":"培养法结合生化与血清学确认"},{"_id":"6a832b7f884ede9a1b2c56bb","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady kod: 19 08 02; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Liczba żywych jaj pasożytów jelitowych Ascaris sp. Trichuris sp., Toxocara sp.","parameters":[{"name":"Zakres","range":"od 1 jaja/100g"}],"technique":"Metoda mikroskopowa","techniques":["Metoda mikroskopowa"],"computed":[],"activity":"Liczba żywych jaj pasożytów jelitowych Ascaris sp. Trichuris sp., Toxocara sp.\nZakres od 1 jaja/100g\nMetoda mikroskopowa","reference":"EFO/PB/35/A:05.05.2025","norm_bases":["EFO/PB/35/A:05.05.2025"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady kod: 19 08 02; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Liczba żywych jaj pasożytów jelitowych Ascaris sp. Trichuris sp., Toxocara sp.\nZakres od 1 jaja/100g\nMetoda mikroskopowa EFO/PB/35/A:05.05.2025 Odpady kod: 19 08 02; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Liczba zywych jaj pasozytow jelitowych Ascaris sp. Trichuris sp., Toxocara sp.\nZakres od 1 jaja/100g\nMetoda mikroskopowa EFO/PB/35/A:05.05.2025","categories":["environment","food"],"row_index":499,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of viable eggs of intestinal parasites Ascaris sp. Trichuris sp., Toxocara sp.","parameters_en":[{"name":"Range","range":"od 1 jaja/100g"}],"search_en":"Count of viable eggs of intestinal parasites Ascaris sp. Trichuris sp., Toxocara sp. Microscopic method Range EFO/PB/35/A:05.05.2025","technique_en":"Microscopic method","parameters_zh":[{"name":"范围","range":"od 1 jaja/100g"}],"search_zh":"显微镜法 范围 EFO/PB/35/A:05.05.2025","technique_zh":"显微镜法"},{"_id":"6a832b7f884ede9a1b2c56bc","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady ściekowe, gleba","methodology":"Obecność Salmonella spp. w 25g dla odpadów, gleby, w 100g dla osadów ściekowych","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella spp. w 25g dla odpadów, gleby, w 100g dla osadów ściekowych\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04+A1:2020-09","norm_bases":["PN-EN ISO 6579-1:2017-04+A1:2020-09"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, gleba Obecność Salmonella spp. w 25g dla odpadów, gleby, w 100g dla osadów ściekowych\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04+A1:2020-09 Osady sciekowe, gleba Obecnosc Salmonella spp. w 25g dla odpadow, gleby, w 100g dla osadow sciekowych\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04+A1:2020-09","categories":["water","environment","microbiology"],"row_index":500,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp. in 25g for waste, soil, in 100g for sewage sludge","search_en":"Sewage sludge, soil Presence of Salmonella spp. in 25g for waste, soil, in 100g for sewage sludge Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04+A1:2020-09","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Sewage sludge, soil","search_zh":"培养法结合生化与血清学确认 PN-EN ISO 6579-1:2017-04+A1:2020-09","technique_zh":"培养法结合生化与血清学确认"},{"_id":"6a832b7f884ede9a1b2c56bd","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Osady ściekowe, gleba","methodology":"Liczba żywych jaj pasożytów jelitowych Ascaris sp. Trichuris sp., Toxocara sp.","parameters":[{"name":"Zakres","range":"od 1 jaja/100g"}],"technique":"Metoda mikroskopowa","techniques":["Metoda mikroskopowa"],"computed":[],"activity":"Liczba żywych jaj pasożytów jelitowych Ascaris sp. Trichuris sp., Toxocara sp.\nZakres od 1 jaja/100g\nMetoda mikroskopowa","reference":"EFO/PB/35/A:05.05.2025","norm_bases":["EFO/PB/35/A:05.05.2025"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, gleba Liczba żywych jaj pasożytów jelitowych Ascaris sp. Trichuris sp., Toxocara sp.\nZakres od 1 jaja/100g\nMetoda mikroskopowa EFO/PB/35/A:05.05.2025 Osady sciekowe, gleba Liczba zywych jaj pasozytow jelitowych Ascaris sp. Trichuris sp., Toxocara sp.\nZakres od 1 jaja/100g\nMetoda mikroskopowa EFO/PB/35/A:05.05.2025","categories":["water","food","environment"],"row_index":501,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of viable eggs of intestinal parasites Ascaris sp. Trichuris sp., Toxocara sp.","parameters_en":[{"name":"Range","range":"od 1 jaja/100g"}],"search_en":"Sewage sludge, soil Count of viable eggs of intestinal parasites Ascaris sp. Trichuris sp., Toxocara sp. Microscopic method Range EFO/PB/35/A:05.05.2025","technique_en":"Microscopic method","test_object_en":"Sewage sludge, soil","parameters_zh":[{"name":"范围","range":"od 1 jaja/100g"}],"search_zh":"显微镜法 范围 EFO/PB/35/A:05.05.2025","technique_zh":"显微镜法"},{"_id":"6a832b7f884ede9a1b2c56be","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko ogólne - powietrze","methodology":"Ogólna liczba bakterii","parameters":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"computed":[],"activity":"Ogólna liczba bakterii\nMetoda hodowlana","reference":"PB/BB/13/A:02.01.2012","norm_bases":["PB/BB/13/A:02.01.2012"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - powietrze Ogólna liczba bakterii\nMetoda hodowlana PB/BB/13/A:02.01.2012 Srodowisko ogolne - powietrze Ogolna liczba bakterii\nMetoda hodowlana PB/BB/13/A:02.01.2012","categories":["environment","microbiology"],"row_index":502,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total bacterial count","search_en":"General environment - air Total bacterial count Culture method PB/BB/13/A:02.01.2012","technique_en":"Culture method","test_object_en":"General environment - air","search_zh":"一般环境 － 空气 细菌总数 培养法 PB/BB/13/A:02.01.2012","technique_zh":"培养法","methodology_zh":"细菌总数","test_object_zh":"一般环境 － 空气"},{"_id":"6a832b7f884ede9a1b2c56bf","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko ogólne - powietrze","methodology":"Ogólna liczba drożdży i pleśni","parameters":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"computed":[],"activity":"Ogólna liczba drożdży i pleśni\nMetoda hodowlana","reference":"PB/BB/13/A:02.01.2012","norm_bases":["PB/BB/13/A:02.01.2012"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - powietrze Ogólna liczba drożdży i pleśni\nMetoda hodowlana PB/BB/13/A:02.01.2012 Srodowisko ogolne - powietrze Ogolna liczba drozdzy i plesni\nMetoda hodowlana PB/BB/13/A:02.01.2012","categories":["environment"],"row_index":503,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total yeast and mould count","search_en":"General environment - air Total yeast and mould count Culture method PB/BB/13/A:02.01.2012","technique_en":"Culture method","test_object_en":"General environment - air","search_zh":"一般环境 － 空气 培养法 PB/BB/13/A:02.01.2012","technique_zh":"培养法","test_object_zh":"一般环境 － 空气"},{"_id":"6a832b7f884ede9a1b2c56c0","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Środowisko ogólne - powietrze","methodology":"Ogólna liczba promieniowców","parameters":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"computed":[],"activity":"Ogólna liczba promieniowców\nMetoda hodowlana","reference":"PB/BB/13/A:02.01.2012","norm_bases":["PB/BB/13/A:02.01.2012"],"lab_section":"Sekcja Badań Biologicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - powietrze Ogólna liczba promieniowców\nMetoda hodowlana PB/BB/13/A:02.01.2012 Srodowisko ogolne - powietrze Ogolna liczba promieniowcow\nMetoda hodowlana PB/BB/13/A:02.01.2012","categories":["environment"],"row_index":504,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total count of actinomycetes","search_en":"General environment - air Total count of actinomycetes Culture method PB/BB/13/A:02.01.2012","technique_en":"Culture method","test_object_en":"General environment - air","search_zh":"一般环境 － 空气 培养法 PB/BB/13/A:02.01.2012","technique_zh":"培养法","test_object_zh":"一般环境 － 空气"},{"_id":"6a832b7f884ede9a1b2c56c1","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"pH – w KCl, pH - w H2O, pH – w CaCl2","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH – w KCl, pH - w H2O, pH – w CaCl2\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09 | ISO 10390:2005 | ISO 10390:2021","norm_bases":["PN-EN ISO 10390:2022-09","ISO 10390:2005","ISO 10390:2021"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty pH – w KCl, pH - w H2O, pH – w CaCl2\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 | ISO 10390:2005 | ISO 10390:2021 Gleba, grunty pH – w KCl, pH - w H2O, pH – w CaCl2\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 | ISO 10390:2005 | ISO 10390:2021","categories":["environment"],"row_index":505,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH – in KCl, pH - in H2O, pH – in CaCl2","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Soil, ground pH – in KCl, pH - in H2O, pH – in CaCl2 Potentiometric method Range PN-EN ISO 10390:2022-09 | ISO 10390:2005 | ISO 10390:2021","technique_en":"Potentiometric method","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"土壤、土体 电位法 范围 PN-EN ISO 10390:2022-09 | ISO 10390:2005 | ISO 10390:2021","technique_zh":"电位法","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c56c2","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Wodoprzepuszczalność – współczynnik filtracji","parameters":[{"name":"Zakres","range":"(1,0·10-8 – 1,0·10-5) m/s"}],"technique":"Metoda spadków hydraulicznych","techniques":["Metoda spadków hydraulicznych"],"computed":[],"activity":"Wodoprzepuszczalność – współczynnik filtracji\nZakres (1,0·10-8 – 1,0·10-5) m/s\nMetoda spadków hydraulicznych","reference":"PKN-CEN ISO/TS 17892-11:2009","norm_bases":["PKN-CEN ISO/TS 17892-11:2009"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Wodoprzepuszczalność – współczynnik filtracji\nZakres (1,0·10-8 – 1,0·10-5) m/s\nMetoda spadków hydraulicznych PKN-CEN ISO/TS 17892-11:2009 Gleba, grunty Wodoprzepuszczalnosc – wspolczynnik filtracji\nZakres (1,0·10-8 – 1,0·10-5) m/s\nMetoda spadkow hydraulicznych PKN-CEN ISO/TS 17892-11:2009","categories":["environment"],"row_index":506,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water permeability – coefficient of permeability","parameters_en":[{"name":"Range","range":"(1,0·10-8 – 1,0·10-5) m/s"}],"search_en":"Soil, ground Water permeability – coefficient of permeability Hydraulic gradient method Range PKN-CEN ISO/TS 17892-11:2009","technique_en":"Hydraulic gradient method","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(1,0·10-8 – 1,0·10-5) m/s"}],"search_zh":"土壤、土体 透水性 － 渗透系数 水力坡降法 范围 PKN-CEN ISO/TS 17892-11:2009","test_object_zh":"土壤、土体","methodology_zh":"透水性 － 渗透系数","technique_zh":"水力坡降法"},{"_id":"6a832b7f884ede9a1b2c56c3","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Wodoprzepuszczalność – współczynnik filtracji","parameters":[{"name":"Zakres","range":"(1,0·10-5 – 1,0·10-2) m/s"},{"name":"(z obliczeń na podstawie krzywej uziarnienia – wzór USBSC)"}],"technique":null,"techniques":[],"computed":[],"activity":"Wodoprzepuszczalność – współczynnik filtracji\nZakres:\nZakres (1,0·10-5 – 1,0·10-2) m/s\n(z obliczeń na podstawie krzywej uziarnienia – wzór USBSC)","reference":"EFO/PB/12/A: 01.08.2022","norm_bases":["EFO/PB/12/A: 01.08.2022"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Wodoprzepuszczalność – współczynnik filtracji\nZakres:\nZakres (1,0·10-5 – 1,0·10-2) m/s\n(z obliczeń na podstawie krzywej uziarnienia – wzór USBSC) EFO/PB/12/A: 01.08.2022 Gleba, grunty Wodoprzepuszczalnosc – wspolczynnik filtracji\nZakres:\nZakres (1,0·10-5 – 1,0·10-2) m/s\n(z obliczen na podstawie krzywej uziarnienia – wzor USBSC) EFO/PB/12/A: 01.08.2022","categories":["environment"],"row_index":507,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water permeability – coefficient of permeability","parameters_en":[{"name":"Range","range":"(1,0·10-5 – 1,0·10-2) m/s"},{"name":"(calculated from the particle size distribution curve – USBSC formula)"}],"search_en":"Soil, ground Water permeability – coefficient of permeability Range (calculated from the particle size distribution curve – USBSC formula) EFO/PB/12/A: 01.08.2022","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(1,0·10-5 – 1,0·10-2) m/s"},{"name":"（依据颗粒级配曲线计算得出 － USBSC 公式）"}],"search_zh":"土壤、土体 透水性 － 渗透系数 范围 （依据颗粒级配曲线计算得出 － USBSC 公式） EFO/PB/12/A: 01.08.2022","test_object_zh":"土壤、土体","methodology_zh":"透水性 － 渗透系数"},{"_id":"6a832b7f884ede9a1b2c56c4","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Zawartość chlorobenzenów","parameters":[{"name":"Zakres","range":"1,2,3,4-tetrachlorobenzen"},{"name":"Zakres","range":"(0,005 – 2,5) mg/kg"},{"name":"1,2,3,5-tetrachlorobenzen","range":"(0,005 – 2,5) mg/kg"},{"name":"1,2,4,5-tetrachlorobenzen","range":"(0,005 – 2,5) mg/kg"},{"name":"pentachlorobenzen","range":"(0,005 – 2,5) mg/kg"},{"name":"heksachlorobenzen (HCB)","range":"(0,005 – 2,5) mg/kg"},{"name":"Suma tetrachlorobenzenów (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość chlorobenzenów\nZakres:\nZakres 1,2,3,4-tetrachlorobenzen\nZakres (0,005 – 2,5) mg/kg\n1,2,3,5-tetrachlorobenzen (0,005 – 2,5) mg/kg\n1,2,4,5-tetrachlorobenzen (0,005 – 2,5) mg/kg\npentachlorobenzen (0,005 – 2,5) mg/kg\nheksachlorobenzen (HCB) (0,005 – 2,5) mg/kg\nSuma tetrachlorobenzenów (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"EFO/PB/11/B: 23.01.2025","norm_bases":["EFO/PB/11/B: 23.01.2025"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Zawartość chlorobenzenów\nZakres:\nZakres 1,2,3,4-tetrachlorobenzen\nZakres (0,005 – 2,5) mg/kg\n1,2,3,5-tetrachlorobenzen (0,005 – 2,5) mg/kg\n1,2,4,5-tetrachlorobenzen (0,005 – 2,5) mg/kg\npentachlorobenzen (0,005 – 2,5) mg/kg\nheksachlorobenzen (HCB) (0,005 – 2,5) mg/kg\nSuma tetrachlorobenzenów (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) EFO/PB/11/B: 23.01.2025 Gleba, grunty Zawartosc chlorobenzenow\nZakres:\nZakres 1,2,3,4-tetrachlorobenzen\nZakres (0,005 – 2,5) mg/kg\n1,2,3,5-tetrachlorobenzen (0,005 – 2,5) mg/kg\n1,2,4,5-tetrachlorobenzen (0,005 – 2,5) mg/kg\npentachlorobenzen (0,005 – 2,5) mg/kg\nheksachlorobenzen (HCB) (0,005 – 2,5) mg/kg\nSuma tetrachlorobenzenow (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) EFO/PB/11/B: 23.01.2025","categories":["environment"],"row_index":508,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorobenzene content","parameters_en":[{"name":"Range","range":"1,2,3,4-tetrachlorobenzen"},{"name":"Range","range":"(0,005 – 2,5) mg/kg"},{"name":"1,2,3,5-tetrachlorobenzene","range":"(0,005 – 2,5) mg/kg"},{"name":"1,2,4,5-tetrachlorobenzene","range":"(0,005 – 2,5) mg/kg"},{"name":"pentachlorobenzene","range":"(0,005 – 2,5) mg/kg"},{"name":"hexachlorobenzene (HCB)","range":"(0,005 – 2,5) mg/kg"},{"name":"Sum of tetrachlorobenzenes (calculated)"}],"search_en":"Soil, ground Chlorobenzene content Gas chromatography with mass spectrometry detection (GC-MS) Range Range 1,2,3,5-tetrachlorobenzene 1,2,4,5-tetrachlorobenzene pentachlorobenzene hexachlorobenzene (HCB) Sum of tetrachlorobenzenes (calculated) EFO/PB/11/B: 23.01.2025","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"1,2,3,4-tetrachlorobenzen"},{"name":"范围","range":"(0,005 – 2,5) mg/kg"},{"name":"1,2,3,5-tetrachlorobenzen","range":"(0,005 – 2,5) mg/kg"},{"name":"1,2,4,5-tetrachlorobenzen","range":"(0,005 – 2,5) mg/kg"},{"name":"五氯苯","range":"(0,005 – 2,5) mg/kg"},{"name":"六氯苯（HCB）","range":"(0,005 – 2,5) mg/kg"},{"name":"Suma tetrachlorobenzenów (z obliczeń)"}],"search_zh":"土壤、土体 氯苯类含量 气相色谱-质谱法（GC-MS） 范围 范围 五氯苯 六氯苯（HCB） EFO/PB/11/B: 23.01.2025","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"土壤、土体","methodology_zh":"氯苯类含量"},{"_id":"6a832b7f884ede9a1b2c56c5","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Skład granulometryczny","parameters":[{"name":"Zakres","range":"(0,063 – 63,0) mm"}],"technique":"Metoda sitowa","techniques":["Metoda sitowa"],"computed":[],"activity":"Skład granulometryczny\nZakres (0,063 – 63,0) mm\nMetoda sitowa","reference":"PN-EN ISO 17892-4:2017-01","norm_bases":["PN-EN ISO 17892-4:2017-01"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Skład granulometryczny\nZakres (0,063 – 63,0) mm\nMetoda sitowa PN-EN ISO 17892-4:2017-01 Gleba, grunty Sklad granulometryczny\nZakres (0,063 – 63,0) mm\nMetoda sitowa PN-EN ISO 17892-4:2017-01","categories":["environment"],"row_index":509,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Particle size distribution","parameters_en":[{"name":"Range","range":"(0,063 – 63,0) mm"}],"search_en":"Soil, ground Particle size distribution Sieve method Range PN-EN ISO 17892-4:2017-01","technique_en":"Sieve method","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(0,063 – 63,0) mm"}],"search_zh":"土壤、土体 粒度组成 筛析法 范围 PN-EN ISO 17892-4:2017-01","test_object_zh":"土壤、土体","methodology_zh":"粒度组成","technique_zh":"筛析法"},{"_id":"6a832b7f884ede9a1b2c56c6","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Skład granulometryczny w zakresie wielkości cząstek (0,002 – 2,00) mm z podziałem na frakcje","parameters":[{"name":"Zakres","range":"(1 – 99) %"}],"technique":"Metoda areometryczna","techniques":["Metoda areometryczna"],"computed":[],"activity":"Skład granulometryczny w zakresie wielkości cząstek (0,002 – 2,00) mm z podziałem na frakcje\nZakres (1 – 99) %\nMetoda areometryczna","reference":"PN-R-04032:1998 pkt. 3.1","norm_bases":["PN-R-04032:1998 pkt. 3.1"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Skład granulometryczny w zakresie wielkości cząstek (0,002 – 2,00) mm z podziałem na frakcje\nZakres (1 – 99) %\nMetoda areometryczna PN-R-04032:1998 pkt. 3.1 Gleba, grunty Sklad granulometryczny w zakresie wielkosci czastek (0,002 – 2,00) mm z podzialem na frakcje\nZakres (1 – 99) %\nMetoda areometryczna PN-R-04032:1998 pkt. 3.1","categories":["environment"],"row_index":510,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Particle size distribution in the particle size range (0,002 – 2,00) mm divided into fractions","parameters_en":[{"name":"Range","range":"(1 – 99) %"}],"search_en":"Soil, ground Particle size distribution in the particle size range (0,002 – 2,00) mm divided into fractions Hydrometer method Range PN-R-04032:1998 pkt. 3.1","technique_en":"Hydrometer method","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(1 – 99) %"}],"search_zh":"土壤、土体 比重计法 范围 PN-R-04032:1998 pkt. 3.1","test_object_zh":"土壤、土体","technique_zh":"比重计法"},{"_id":"6a832b7f884ede9a1b2c56c7","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Zawartość chloronaftalenów","parameters":[{"name":"Zakres","range":"1-chloronaftalen (0,01 – 10) mg/kg"},{"name":"2-chloronaftalen","range":"(0,01 – 10) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość chloronaftalenów\nZakres:\nZakres 1-chloronaftalen (0,01 – 10) mg/kg\n2-chloronaftalen (0,01 – 10) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"EFO/PB/16/B: 29.05.2024","norm_bases":["EFO/PB/16/B: 29.05.2024"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Zawartość chloronaftalenów\nZakres:\nZakres 1-chloronaftalen (0,01 – 10) mg/kg\n2-chloronaftalen (0,01 – 10) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) EFO/PB/16/B: 29.05.2024 Gleba, grunty Zawartosc chloronaftalenow\nZakres:\nZakres 1-chloronaftalen (0,01 – 10) mg/kg\n2-chloronaftalen (0,01 – 10) mg/kg\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) EFO/PB/16/B: 29.05.2024","categories":["environment"],"row_index":511,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloronaphthalene content","parameters_en":[{"name":"Range","range":"1-chloronaftalen (0,01 – 10) mg/kg"},{"name":"2-chloronaphthalene","range":"(0,01 – 10) mg/kg"}],"search_en":"Soil, ground Chloronaphthalene content Gas chromatography with mass spectrometry detection (GC-MS) Range 2-chloronaphthalene EFO/PB/16/B: 29.05.2024","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"1-chloronaftalen (0,01 – 10) mg/kg"},{"name":"2-chloronaftalen","range":"(0,01 – 10) mg/kg"}],"search_zh":"土壤、土体 氯代萘含量 气相色谱-质谱法（GC-MS） 范围 EFO/PB/16/B: 29.05.2024","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"土壤、土体","methodology_zh":"氯代萘含量"},{"_id":"6a832b7f884ede9a1b2c56c8","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Suma chloronaftalenów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma chloronaftalenów (z obliczeń)","reference":"EFO/PB/16/B: 29.05.2024","norm_bases":["EFO/PB/16/B: 29.05.2024"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Suma chloronaftalenów (z obliczeń) EFO/PB/16/B: 29.05.2024 Gleba, grunty Suma chloronaftalenow (z obliczen) EFO/PB/16/B: 29.05.2024","categories":["environment"],"row_index":512,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of chloronaphthalenes (calculated)","search_en":"Soil, ground Sum of chloronaphthalenes (calculated) EFO/PB/16/B: 29.05.2024","test_object_en":"Soil, ground","search_zh":"土壤、土体 EFO/PB/16/B: 29.05.2024","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c56c9","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty, Odpady kod: 17 05 04; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość fenolu","parameters":[{"name":"Zakres","range":"(0,050 – 10) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość fenolu\nZakres (0,050 – 10) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"EFO/PB/16/B: 29.05.2024","norm_bases":["EFO/PB/16/B: 29.05.2024"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty, Odpady kod: 17 05 04; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość fenolu\nZakres (0,050 – 10) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) EFO/PB/16/B: 29.05.2024 Gleba, grunty, Odpady kod: 17 05 04; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc fenolu\nZakres (0,050 – 10) mg/kg\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) EFO/PB/16/B: 29.05.2024","categories":["environment"],"row_index":513,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol content","parameters_en":[{"name":"Range","range":"(0,050 – 10) mg/kg"}],"search_en":"Phenol content Gas chromatography with mass spectrometry detection (GC-MS) Range EFO/PB/16/B: 29.05.2024","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","parameters_zh":[{"name":"范围","range":"(0,050 – 10) mg/kg"}],"search_zh":"苯酚含量 气相色谱-质谱法（GC-MS） 范围 EFO/PB/16/B: 29.05.2024","technique_zh":"气相色谱-质谱法（GC-MS）","methodology_zh":"苯酚含量"},{"_id":"6a832b7f884ede9a1b2c56ca","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty, Odpady kod: 17 05 04; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość krezoli","parameters":[{"name":"o-krezol","range":"(0,050 – 10) mg/kg"},{"name":"m+p-krezol","range":"(0,10 – 20) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość krezoli\nZakres:\no-krezol (0,050 – 10) mg/kg\nm+p-krezol (0,10 – 20) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"EFO/PB/16/B: 29.05.2024","norm_bases":["EFO/PB/16/B: 29.05.2024"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty, Odpady kod: 17 05 04; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość krezoli\nZakres:\no-krezol (0,050 – 10) mg/kg\nm+p-krezol (0,10 – 20) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) EFO/PB/16/B: 29.05.2024 Gleba, grunty, Odpady kod: 17 05 04; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc krezoli\nZakres:\no-krezol (0,050 – 10) mg/kg\nm+p-krezol (0,10 – 20) mg/kg\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) EFO/PB/16/B: 29.05.2024","categories":["environment"],"row_index":514,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cresol content","parameters_en":[{"name":"o-cresol","range":"(0,050 – 10) mg/kg"},{"name":"m+p-cresol","range":"(0,10 – 20) mg/kg"}],"search_en":"Cresol content Gas chromatography with mass spectrometry detection (GC-MS) o-cresol m+p-cresol EFO/PB/16/B: 29.05.2024","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","search_zh":"甲酚含量 气相色谱-质谱法（GC-MS） 邻甲酚 EFO/PB/16/B: 29.05.2024","technique_zh":"气相色谱-质谱法（GC-MS）","methodology_zh":"甲酚含量","parameters_zh":[{"name":"邻甲酚","range":"(0,050 – 10) mg/kg"},{"name":"m+p-krezol","range":"(0,10 – 20) mg/kg"}]},{"_id":"6a832b7f884ede9a1b2c56cb","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty, Odpady kod: 17 05 04; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Suma krezoli (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma krezoli (z obliczeń)","reference":"EFO/PB/16/B: 29.05.2024","norm_bases":["EFO/PB/16/B: 29.05.2024"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty, Odpady kod: 17 05 04; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Suma krezoli (z obliczeń) EFO/PB/16/B: 29.05.2024 Gleba, grunty, Odpady kod: 17 05 04; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Suma krezoli (z obliczen) EFO/PB/16/B: 29.05.2024","categories":["environment"],"row_index":515,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of cresols (calculated)","search_en":"Sum of cresols (calculated) EFO/PB/16/B: 29.05.2024","methodology_zh":"甲酚总量（由计算得出）","search_zh":"甲酚总量（由计算得出） EFO/PB/16/B: 29.05.2024"},{"_id":"6a832b7f884ede9a1b2c56cc","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Zawartość polichlorowanych bifenyli","parameters":[{"name":"PCB 28","range":"(0,002 – 10) mg/kg"},{"name":"PCB 52","range":"(0,002 – 10) mg/kg"},{"name":"PCB 101","range":"(0,002 – 10) mg/kg"},{"name":"PCB 118","range":"(0,002 – 10) mg/kg"},{"name":"PCB 138","range":"(0,002 – 10) mg/kg"},{"name":"PCB 153","range":"(0,002 – 10) mg/kg"},{"name":"PCB 180","range":"(0,002 – 10) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość polichlorowanych bifenyli\nZakres:\nPCB 28 (0,002 – 10) mg/kg\nPCB 52 (0,002 – 10) mg/kg\nPCB 101 (0,002 – 10) mg/kg\nPCB 118 (0,002 – 10) mg/kg\nPCB 138 (0,002 – 10) mg/kg\nPCB 153 (0,002 – 10) mg/kg\nPCB 180 (0,002 – 10) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PN-EN 17322:2021-01","norm_bases":["PN-EN 17322:2021-01"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Zawartość polichlorowanych bifenyli\nZakres:\nPCB 28 (0,002 – 10) mg/kg\nPCB 52 (0,002 – 10) mg/kg\nPCB 101 (0,002 – 10) mg/kg\nPCB 118 (0,002 – 10) mg/kg\nPCB 138 (0,002 – 10) mg/kg\nPCB 153 (0,002 – 10) mg/kg\nPCB 180 (0,002 – 10) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PN-EN 17322:2021-01 Gleba, grunty Zawartosc polichlorowanych bifenyli\nZakres:\nPCB 28 (0,002 – 10) mg/kg\nPCB 52 (0,002 – 10) mg/kg\nPCB 101 (0,002 – 10) mg/kg\nPCB 118 (0,002 – 10) mg/kg\nPCB 138 (0,002 – 10) mg/kg\nPCB 153 (0,002 – 10) mg/kg\nPCB 180 (0,002 – 10) mg/kg\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PN-EN 17322:2021-01","categories":["environment"],"row_index":516,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polychlorinated biphenyl content","parameters_en":[{"name":"PCB 28","range":"(0,002 – 10) mg/kg"},{"name":"PCB 52","range":"(0,002 – 10) mg/kg"},{"name":"PCB 101","range":"(0,002 – 10) mg/kg"},{"name":"PCB 118","range":"(0,002 – 10) mg/kg"},{"name":"PCB 138","range":"(0,002 – 10) mg/kg"},{"name":"PCB 153","range":"(0,002 – 10) mg/kg"},{"name":"PCB 180","range":"(0,002 – 10) mg/kg"}],"search_en":"Soil, ground Polychlorinated biphenyl content Gas chromatography with mass spectrometry detection (GC-MS) PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 PN-EN 17322:2021-01","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Soil, ground","search_zh":"土壤、土体 多氯联苯含量 气相色谱-质谱法（GC-MS） PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 PN-EN 17322:2021-01","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"土壤、土体","parameters_zh":[{"name":"PCB 28","range":"(0,002 – 10) mg/kg"},{"name":"PCB 52","range":"(0,002 – 10) mg/kg"},{"name":"PCB 101","range":"(0,002 – 10) mg/kg"},{"name":"PCB 118","range":"(0,002 – 10) mg/kg"},{"name":"PCB 138","range":"(0,002 – 10) mg/kg"},{"name":"PCB 153","range":"(0,002 – 10) mg/kg"},{"name":"PCB 180","range":"(0,002 – 10) mg/kg"}],"methodology_zh":"多氯联苯含量"},{"_id":"6a832b7f884ede9a1b2c56cd","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Suma polichlorowanych bifenyli (PCB) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma polichlorowanych bifenyli (PCB) (z obliczeń)","reference":"PN-EN 17322:2021-01","norm_bases":["PN-EN 17322:2021-01"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Suma polichlorowanych bifenyli (PCB) (z obliczeń) PN-EN 17322:2021-01 Gleba, grunty Suma polichlorowanych bifenyli (PCB) (z obliczen) PN-EN 17322:2021-01","categories":["environment"],"row_index":517,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of polychlorinated biphenyls (PCB) (calculated)","search_en":"Soil, ground Sum of polychlorinated biphenyls (PCB) (calculated) PN-EN 17322:2021-01","test_object_en":"Soil, ground","search_zh":"土壤、土体 多氯联苯（PCB）总量（由计算得出） PN-EN 17322:2021-01","test_object_zh":"土壤、土体","methodology_zh":"多氯联苯（PCB）总量（由计算得出）"},{"_id":"6a832b7f884ede9a1b2c56ce","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Sucha masa","parameters":[{"name":"Zakres","range":"(0,10 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa\nZakres (0,10 – 99,0) %\nMetoda wagowa","reference":"PN-ISO 11465:1999 | PN-EN 15934:2013-02","norm_bases":["PN-ISO 11465:1999","PN-EN 15934:2013-02"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Sucha masa\nZakres (0,10 – 99,0) %\nMetoda wagowa PN-ISO 11465:1999 | PN-EN 15934:2013-02 Gleba, grunty Sucha masa\nZakres (0,10 – 99,0) %\nMetoda wagowa PN-ISO 11465:1999 | PN-EN 15934:2013-02","categories":["environment"],"row_index":518,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter","parameters_en":[{"name":"Range","range":"(0,10 – 99,0) %"}],"search_en":"Soil, ground Dry matter Gravimetric method Range PN-ISO 11465:1999 | PN-EN 15934:2013-02","technique_en":"Gravimetric method","test_object_en":"Soil, ground","methodology_zh":"干物质","parameters_zh":[{"name":"范围","range":"(0,10 – 99,0) %"}],"search_zh":"土壤、土体 干物质 重量法 范围 PN-ISO 11465:1999 | PN-EN 15934:2013-02","technique_zh":"重量法","test_object_zh":"土壤、土体"},{"_id":"6a832b7f884ede9a1b2c56cf","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Zawartość związków organicznych: Tetrahydrofuran (0,2 – 1,0) mg/kg","parameters":[],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Zawartość związków organicznych: Tetrahydrofuran (0,2 – 1,0) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PN-EN ISO 22155:2016-07 EFO/I/06/K wersja 3 z dnia 10.07.2023","norm_bases":["PN-EN ISO 22155:2016-07 EFO/I/06/K wersja 3 z dnia 10.07.2023"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Zawartość związków organicznych: Tetrahydrofuran (0,2 – 1,0) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PN-EN ISO 22155:2016-07 EFO/I/06/K wersja 3 z dnia 10.07.2023 Gleba, grunty Zawartosc zwiazkow organicznych: Tetrahydrofuran (0,2 – 1,0) mg/kg\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PN-EN ISO 22155:2016-07 EFO/I/06/K wersja 3 z dnia 10.07.2023","categories":["environment"],"row_index":519,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of organic compounds: Tetrahydrofuran (0,2 – 1,0) mg/kg","search_en":"Soil, ground Content of organic compounds: Tetrahydrofuran (0,2 – 1,0) mg/kg Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) PN-EN ISO 22155:2016-07 EFO/I/06/K wersja 3 z dnia 10.07.2023","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Soil, ground","search_zh":"土壤、土体 顶空气相色谱-质谱法（HS-GC-MS） PN-EN ISO 22155:2016-07 EFO/I/06/K wersja 3 z dnia 10.07.2023","test_object_zh":"土壤、土体","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）"},{"_id":"6a832b7f884ede9a1b2c56d0","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Zawartość związków organicznych:","parameters":[{"name":"Tetrahydrotiofen (0,10 – 1,0) mg/kg"},{"name":"Cykloheksan (0,10 – 1,0) mg/kg"},{"name":"Pirydyna (0,10 – 1,0) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość związków organicznych:\nZakres:\nTetrahydrotiofen (0,10 – 1,0) mg/kg\nCykloheksan (0,10 – 1,0) mg/kg\nPirydyna (0,10 – 1,0) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"EFO/PB/21/A: 19.05.2023","norm_bases":["EFO/PB/21/A: 19.05.2023"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Zawartość związków organicznych:\nZakres:\nTetrahydrotiofen (0,10 – 1,0) mg/kg\nCykloheksan (0,10 – 1,0) mg/kg\nPirydyna (0,10 – 1,0) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) EFO/PB/21/A: 19.05.2023 Gleba, grunty Zawartosc zwiazkow organicznych:\nZakres:\nTetrahydrotiofen (0,10 – 1,0) mg/kg\nCykloheksan (0,10 – 1,0) mg/kg\nPirydyna (0,10 – 1,0) mg/kg\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) EFO/PB/21/A: 19.05.2023","categories":["environment"],"row_index":520,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Organic compound content:","parameters_en":[{"name":"Tetrahydrothiophene (0,10 – 1,0) mg/kg"},{"name":"Cyclohexane (0,10 – 1,0) mg/kg"},{"name":"Pyridine (0,10 – 1,0) mg/kg"}],"search_en":"Soil, ground Organic compound content: Gas chromatography with mass spectrometry detection (GC-MS) Tetrahydrothiophene (0,10 – 1,0) mg/kg Cyclohexane (0,10 – 1,0) mg/kg Pyridine (0,10 – 1,0) mg/kg EFO/PB/21/A: 19.05.2023","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Soil, ground","search_zh":"土壤、土体 有机化合物含量： 气相色谱-质谱法（GC-MS） EFO/PB/21/A: 19.05.2023","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"土壤、土体","methodology_zh":"有机化合物含量："},{"_id":"6a832b7f884ede9a1b2c56d1","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Zawartość ftalanów","parameters":[{"name":"Ftalan dietylu","range":"(0,10 – 10) mg/kg"},{"name":"Ftalan di-2etyloheksylu (DEHP)"},{"name":"Zakres","range":"(0,10 – 10) mg/kg"},{"name":"Ftalan butylowo-benzylowy","range":"(0,10 – 10) mg/kg"},{"name":"Ftalan di izo-butylu","range":"(0,10 – 10) mg/kg"},{"name":"Ftalan di n-butylu","range":"(0,10 – 10) mg/kg"},{"name":"Suma ftalanów (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość ftalanów\nZakres:\nFtalan dietylu (0,10 – 10) mg/kg\nFtalan di-2etyloheksylu (DEHP)\nZakres (0,10 – 10) mg/kg\nFtalan butylowo-benzylowy (0,10 – 10) mg/kg\nFtalan di izo-butylu (0,10 – 10) mg/kg\nFtalan di n-butylu (0,10 – 10) mg/kg\nSuma ftalanów (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"EFO/PB/37/A:05.05.2025","norm_bases":["EFO/PB/37/A:05.05.2025"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Zawartość ftalanów\nZakres:\nFtalan dietylu (0,10 – 10) mg/kg\nFtalan di-2etyloheksylu (DEHP)\nZakres (0,10 – 10) mg/kg\nFtalan butylowo-benzylowy (0,10 – 10) mg/kg\nFtalan di izo-butylu (0,10 – 10) mg/kg\nFtalan di n-butylu (0,10 – 10) mg/kg\nSuma ftalanów (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) EFO/PB/37/A:05.05.2025 Gleba, grunty Zawartosc ftalanow\nZakres:\nFtalan dietylu (0,10 – 10) mg/kg\nFtalan di-2etyloheksylu (DEHP)\nZakres (0,10 – 10) mg/kg\nFtalan butylowo-benzylowy (0,10 – 10) mg/kg\nFtalan di izo-butylu (0,10 – 10) mg/kg\nFtalan di n-butylu (0,10 – 10) mg/kg\nSuma ftalanow (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) EFO/PB/37/A:05.05.2025","categories":["environment"],"row_index":521,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phthalate content","parameters_en":[{"name":"Diethyl phthalate","range":"(0,10 – 10) mg/kg"},{"name":"Di-2-ethylhexyl phthalate (DEHP)"},{"name":"Range","range":"(0,10 – 10) mg/kg"},{"name":"Butyl benzyl phthalate","range":"(0,10 – 10) mg/kg"},{"name":"Di-iso-butyl phthalate","range":"(0,10 – 10) mg/kg"},{"name":"Di-n-butyl phthalate","range":"(0,10 – 10) mg/kg"},{"name":"Sum of phthalates (calculated)"}],"search_en":"Soil, ground Phthalate content Gas chromatography with mass spectrometry detection (GC-MS) Diethyl phthalate Di-2-ethylhexyl phthalate (DEHP) Range Butyl benzyl phthalate Di-iso-butyl phthalate Di-n-butyl phthalate Sum of phthalates (calculated) EFO/PB/37/A:05.05.2025","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Soil, ground","parameters_zh":[{"name":"邻苯二甲酸二乙酯","range":"(0,10 – 10) mg/kg"},{"name":"Ftalan di-2etyloheksylu (DEHP)"},{"name":"范围","range":"(0,10 – 10) mg/kg"},{"name":"Ftalan butylowo-benzylowy","range":"(0,10 – 10) mg/kg"},{"name":"Ftalan di izo-butylu","range":"(0,10 – 10) mg/kg"},{"name":"Ftalan di n-butylu","range":"(0,10 – 10) mg/kg"},{"name":"邻苯二甲酸酯总量（由计算得出）"}],"search_zh":"土壤、土体 邻苯二甲酸酯含量 气相色谱-质谱法（GC-MS） 邻苯二甲酸二乙酯 范围 邻苯二甲酸酯总量（由计算得出） EFO/PB/37/A:05.05.2025","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"土壤、土体","methodology_zh":"邻苯二甲酸酯含量"},{"_id":"6a832b7f884ede9a1b2c56d2","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie pierwiastków","parameters":[{"name":"srebro","range":"(1,0 – 5000) μg/l"},{"name":"arsen","range":"(1,0 – 5000) μg/l"},{"name":"beryl","range":"(0,50 – 5000) μg/l"},{"name":"kadm","range":"(0,50 – 5000) μg/l"},{"name":"kobalt","range":"(1,0 – 5000) μg/l"},{"name":"molibden","range":"(1,0 – 5000) μg/l"},{"name":"antymon","range":"(1,0 – 5000) μg/l"},{"name":"selen","range":"(1,0 – 5000) μg/l"},{"name":"cyna","range":"(1,0 – 5000) μg/l"},{"name":"tytan","range":"(1,0 – 5000) μg/l"},{"name":"tal","range":"(0,50 – 5000) μg/l"},{"name":"uran","range":"(1,0 – 5000) μg/l"},{"name":"wanad","range":"(1,0 – 5000) μg/l"},{"name":"chrom","range":"(1,0 – 5000) μg/l"},{"name":"miedź","range":"(1,0 – 5000) μg/l"},{"name":"nikiel","range":"(1,0 – 5000) μg/l"},{"name":"ołów","range":"(1,0 – 5000) μg/l"},{"name":"glin","range":"(10 – 100000) μg/l"},{"name":"bor","range":"(50 – 100000) μg/l"},{"name":"bar","range":"(5,0 – 100000) μg/l"},{"name":"cynk","range":"(10 – 100000) μg/l"},{"name":"mangan","range":"(5,0 – 100000) μg/l"},{"name":"fosfor","range":"(10 – 100000) μg/l"},{"name":"rtęć","range":"(0,10 – 500) μg/l"},{"name":"wapń","range":"(1000 – 5000000) μg/l"},{"name":"magnez","range":"(500 – 5000000) μg/l"},{"name":"sód","range":"(1000 – 5000000) μg/l"},{"name":"potas","range":"(500 – 5000000) μg/l"},{"name":"żelazo","range":"(10 – 500000) μg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nsrebro (1,0 – 5000) μg/l\narsen (1,0 – 5000) μg/l\nberyl (0,50 – 5000) μg/l\nkadm (0,50 – 5000) μg/l\nkobalt (1,0 – 5000) μg/l\nmolibden (1,0 – 5000) μg/l\nantymon (1,0 – 5000) μg/l\nselen (1,0 – 5000) μg/l\ncyna (1,0 – 5000) μg/l\ntytan (1,0 – 5000) μg/l\ntal (0,50 – 5000) μg/l\nuran (1,0 – 5000) μg/l\nwanad (1,0 – 5000) μg/l\nchrom (1,0 – 5000) μg/l\nmiedź (1,0 – 5000) μg/l\nnikiel (1,0 – 5000) μg/l\nołów (1,0 – 5000) μg/l\nglin (10 – 100000) μg/l\nbor (50 – 100000) μg/l\nbar (5,0 – 100000) μg/l\ncynk (10 – 100000) μg/l\nmangan (5,0 – 100000) μg/l\nfosfor (10 – 100000) μg/l\nrtęć (0,10 – 500) μg/l\nwapń (1000 – 5000000) μg/l\nmagnez (500 – 5000000) μg/l\nsód (1000 – 5000000) μg/l\npotas (500 – 5000000) μg/l\nżelazo (10 – 500000) μg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie pierwiastków\nZakres:\nsrebro (1,0 – 5000) μg/l\narsen (1,0 – 5000) μg/l\nberyl (0,50 – 5000) μg/l\nkadm (0,50 – 5000) μg/l\nkobalt (1,0 – 5000) μg/l\nmolibden (1,0 – 5000) μg/l\nantymon (1,0 – 5000) μg/l\nselen (1,0 – 5000) μg/l\ncyna (1,0 – 5000) μg/l\ntytan (1,0 – 5000) μg/l\ntal (0,50 – 5000) μg/l\nuran (1,0 – 5000) μg/l\nwanad (1,0 – 5000) μg/l\nchrom (1,0 – 5000) μg/l\nmiedź (1,0 – 5000) μg/l\nnikiel (1,0 – 5000) μg/l\nołów (1,0 – 5000) μg/l\nglin (10 – 100000) μg/l\nbor (50 – 100000) μg/l\nbar (5,0 – 100000) μg/l\ncynk (10 – 100000) μg/l\nmangan (5,0 – 100000) μg/l\nfosfor (10 – 100000) μg/l\nrtęć (0,10 – 500) μg/l\nwapń (1000 – 5000000) μg/l\nmagnez (500 – 5000000) μg/l\nsód (1000 – 5000000) μg/l\npotas (500 – 5000000) μg/l\nżelazo (10 – 500000) μg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Woda, Woda do spozycia przez ludzi Stezenie pierwiastkow\nZakres:\nsrebro (1,0 – 5000) μg/l\narsen (1,0 – 5000) μg/l\nberyl (0,50 – 5000) μg/l\nkadm (0,50 – 5000) μg/l\nkobalt (1,0 – 5000) μg/l\nmolibden (1,0 – 5000) μg/l\nantymon (1,0 – 5000) μg/l\nselen (1,0 – 5000) μg/l\ncyna (1,0 – 5000) μg/l\ntytan (1,0 – 5000) μg/l\ntal (0,50 – 5000) μg/l\nuran (1,0 – 5000) μg/l\nwanad (1,0 – 5000) μg/l\nchrom (1,0 – 5000) μg/l\nmiedz (1,0 – 5000) μg/l\nnikiel (1,0 – 5000) μg/l\nolow (1,0 – 5000) μg/l\nglin (10 – 100000) μg/l\nbor (50 – 100000) μg/l\nbar (5,0 – 100000) μg/l\ncynk (10 – 100000) μg/l\nmangan (5,0 – 100000) μg/l\nfosfor (10 – 100000) μg/l\nrtec (0,10 – 500) μg/l\nwapn (1000 – 5000000) μg/l\nmagnez (500 – 5000000) μg/l\nsod (1000 – 5000000) μg/l\npotas (500 – 5000000) μg/l\nzelazo (10 – 500000) μg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["water","materials"],"row_index":522,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"silver","range":"(1,0 – 5000) μg/l"},{"name":"arsenic","range":"(1,0 – 5000) μg/l"},{"name":"beryllium","range":"(0,50 – 5000) μg/l"},{"name":"cadmium","range":"(0,50 – 5000) μg/l"},{"name":"cobalt","range":"(1,0 – 5000) μg/l"},{"name":"molybdenum","range":"(1,0 – 5000) μg/l"},{"name":"antimony","range":"(1,0 – 5000) μg/l"},{"name":"selenium","range":"(1,0 – 5000) μg/l"},{"name":"tin","range":"(1,0 – 5000) μg/l"},{"name":"titanium","range":"(1,0 – 5000) μg/l"},{"name":"thallium","range":"(0,50 – 5000) μg/l"},{"name":"uranium","range":"(1,0 – 5000) μg/l"},{"name":"vanadium","range":"(1,0 – 5000) μg/l"},{"name":"chromium","range":"(1,0 – 5000) μg/l"},{"name":"copper","range":"(1,0 – 5000) μg/l"},{"name":"nickel","range":"(1,0 – 5000) μg/l"},{"name":"lead","range":"(1,0 – 5000) μg/l"},{"name":"aluminium","range":"(10 – 100000) μg/l"},{"name":"boron","range":"(50 – 100000) μg/l"},{"name":"barium","range":"(5,0 – 100000) μg/l"},{"name":"zinc","range":"(10 – 100000) μg/l"},{"name":"manganese","range":"(5,0 – 100000) μg/l"},{"name":"phosphorus","range":"(10 – 100000) μg/l"},{"name":"mercury","range":"(0,10 – 500) μg/l"},{"name":"calcium","range":"(1000 – 5000000) μg/l"},{"name":"magnesium","range":"(500 – 5000000) μg/l"},{"name":"sodium","range":"(1000 – 5000000) μg/l"},{"name":"potassium","range":"(500 – 5000000) μg/l"},{"name":"iron","range":"(10 – 500000) μg/l"}],"search_en":"Water, Water intended for human consumption Element concentration Inductively coupled plasma mass spectrometry (ICP-MS) silver arsenic beryllium cadmium cobalt molybdenum antimony selenium tin titanium thallium uranium vanadium chromium copper nickel lead aluminium boron barium zinc manganese phosphorus mercury calcium magnesium sodium potassium iron PN-EN ISO 17294-2:2024-04","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Water, Water intended for human consumption","methodology_zh":"元素浓度","parameters_zh":[{"name":"银","range":"(1,0 – 5000) μg/l"},{"name":"砷","range":"(1,0 – 5000) μg/l"},{"name":"铍","range":"(0,50 – 5000) μg/l"},{"name":"镉","range":"(0,50 – 5000) μg/l"},{"name":"钴","range":"(1,0 – 5000) μg/l"},{"name":"钼","range":"(1,0 – 5000) μg/l"},{"name":"锑","range":"(1,0 – 5000) μg/l"},{"name":"硒","range":"(1,0 – 5000) μg/l"},{"name":"锡","range":"(1,0 – 5000) μg/l"},{"name":"钛","range":"(1,0 – 5000) μg/l"},{"name":"铊","range":"(0,50 – 5000) μg/l"},{"name":"铀","range":"(1,0 – 5000) μg/l"},{"name":"钒","range":"(1,0 – 5000) μg/l"},{"name":"铬","range":"(1,0 – 5000) μg/l"},{"name":"铜","range":"(1,0 – 5000) μg/l"},{"name":"镍","range":"(1,0 – 5000) μg/l"},{"name":"铅","range":"(1,0 – 5000) μg/l"},{"name":"铝","range":"(10 – 100000) μg/l"},{"name":"硼","range":"(50 – 100000) μg/l"},{"name":"钡","range":"(5,0 – 100000) μg/l"},{"name":"锌","range":"(10 – 100000) μg/l"},{"name":"锰","range":"(5,0 – 100000) μg/l"},{"name":"磷","range":"(10 – 100000) μg/l"},{"name":"汞","range":"(0,10 – 500) μg/l"},{"name":"钙","range":"(1000 – 5000000) μg/l"},{"name":"镁","range":"(500 – 5000000) μg/l"},{"name":"钠","range":"(1000 – 5000000) μg/l"},{"name":"钾","range":"(500 – 5000000) μg/l"},{"name":"铁","range":"(10 – 500000) μg/l"}],"search_zh":"水、生活饮用水 元素浓度 电感耦合等离子体质谱法（ICP-MS） 银 砷 铍 镉 钴 钼 锑 硒 锡 钛 铊 铀 钒 铬 铜 镍 铅 铝 硼 钡 锌 锰 磷 汞 钙 镁 钠 钾 铁 PN-EN ISO 17294-2:2024-04","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"水、生活饮用水"},{"_id":"6a832b7f884ede9a1b2c56d3","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Indeks oleju mineralnego (C12-C35, C10-C40)","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego (C12-C35, C10-C40)\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003 + EFO/PB/13/A: 01.08.2022","norm_bases":["PN-EN ISO 9377-2:2003 + EFO/PB/13/A: 01.08.2022"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Indeks oleju mineralnego (C12-C35, C10-C40)\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 + EFO/PB/13/A: 01.08.2022 Woda, Scieki Indeks oleju mineralnego (C12-C35, C10-C40)\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003 + EFO/PB/13/A: 01.08.2022","categories":["water","petro"],"row_index":523,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index (C12-C35, C10-C40)","parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/l"}],"search_en":"Water, Wastewater Mineral oil index (C12-C35, C10-C40) Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003 + EFO/PB/13/A: 01.08.2022","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/l"}],"search_zh":"水、污水 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003 + EFO/PB/13/A: 01.08.2022","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、污水"},{"_id":"6a832b7f884ede9a1b2c56d4","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych","parameters":[{"name":"naftalen","range":"(0,50 – 100) μg/l"},{"name":"antracen","range":"(0,030 – 100) μg/l"},{"name":"chryzen","range":"(0,030 – 100) μg/l"},{"name":"benzo(a)antracen","range":"(0,030 – 100) μg/l"},{"name":"dibenzo(a,h)antracen"},{"name":"Zakres","range":"(0,030 – 100) μg/l"},{"name":"benzo(a)piren","range":"(0,030 – 100) μg/l"},{"name":"benzo(b)fluoranten","range":"(0,030 – 100) μg/l"},{"name":"benzo(k)fluoranten","range":"(0,030 – 100) μg/l"},{"name":"benzo(ghi)perylen","range":"(0,030 – 100) μg/l"},{"name":"indeno","range":"(1,2,3-cd)piren"},{"name":"(0,030 – 100) μg/l"},{"name":"acenaften","range":"(0,030 – 100) μg/l"},{"name":"acenaftylen","range":"(0,030 – 100) μg/l"},{"name":"fluoranten","range":"(0,030 – 100) μg/l"},{"name":"fluoren","range":"(0,030 – 100) μg/l"},{"name":"fenantren","range":"(0,030 – 100) μg/l"},{"name":"piren","range":"(0,030 – 100) μg/l"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych\nZakres:\nnaftalen (0,50 – 100) μg/l\nantracen (0,030 – 100) μg/l\nchryzen (0,030 – 100) μg/l\nbenzo(a)antracen (0,030 – 100) μg/l\ndibenzo(a,h)antracen\nZakres (0,030 – 100) μg/l\nbenzo(a)piren (0,030 – 100) μg/l\nbenzo(b)fluoranten (0,030 – 100) μg/l\nbenzo(k)fluoranten (0,030 – 100) μg/l\nbenzo(ghi)perylen (0,030 – 100) μg/l\nindeno (1,2,3-cd)piren\n(0,030 – 100) μg/l\nacenaften (0,030 – 100) μg/l\nacenaftylen (0,030 – 100) μg/l\nfluoranten (0,030 – 100) μg/l\nfluoren (0,030 – 100) μg/l\nfenantren (0,030 – 100) μg/l\npiren (0,030 – 100) μg/l\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"EFO/PB/14/A: 01.08.2022","norm_bases":["EFO/PB/14/A: 01.08.2022"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie wielopierścieniowych węglowodorów aromatycznych\nZakres:\nnaftalen (0,50 – 100) μg/l\nantracen (0,030 – 100) μg/l\nchryzen (0,030 – 100) μg/l\nbenzo(a)antracen (0,030 – 100) μg/l\ndibenzo(a,h)antracen\nZakres (0,030 – 100) μg/l\nbenzo(a)piren (0,030 – 100) μg/l\nbenzo(b)fluoranten (0,030 – 100) μg/l\nbenzo(k)fluoranten (0,030 – 100) μg/l\nbenzo(ghi)perylen (0,030 – 100) μg/l\nindeno (1,2,3-cd)piren\n(0,030 – 100) μg/l\nacenaften (0,030 – 100) μg/l\nacenaftylen (0,030 – 100) μg/l\nfluoranten (0,030 – 100) μg/l\nfluoren (0,030 – 100) μg/l\nfenantren (0,030 – 100) μg/l\npiren (0,030 – 100) μg/l\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) EFO/PB/14/A: 01.08.2022 Woda, Scieki Stezenie wielopierscieniowych weglowodorow aromatycznych\nZakres:\nnaftalen (0,50 – 100) μg/l\nantracen (0,030 – 100) μg/l\nchryzen (0,030 – 100) μg/l\nbenzo(a)antracen (0,030 – 100) μg/l\ndibenzo(a,h)antracen\nZakres (0,030 – 100) μg/l\nbenzo(a)piren (0,030 – 100) μg/l\nbenzo(b)fluoranten (0,030 – 100) μg/l\nbenzo(k)fluoranten (0,030 – 100) μg/l\nbenzo(ghi)perylen (0,030 – 100) μg/l\nindeno (1,2,3-cd)piren\n(0,030 – 100) μg/l\nacenaften (0,030 – 100) μg/l\nacenaftylen (0,030 – 100) μg/l\nfluoranten (0,030 – 100) μg/l\nfluoren (0,030 – 100) μg/l\nfenantren (0,030 – 100) μg/l\npiren (0,030 – 100) μg/l\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) EFO/PB/14/A: 01.08.2022","categories":["water"],"row_index":524,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons","parameters_en":[{"name":"naphthalene","range":"(0,50 – 100) μg/l"},{"name":"anthracene","range":"(0,030 – 100) μg/l"},{"name":"chrysene","range":"(0,030 – 100) μg/l"},{"name":"benzo(a)anthracene","range":"(0,030 – 100) μg/l"},{"name":"dibenzo(a,h)anthracene"},{"name":"Range","range":"(0,030 – 100) μg/l"},{"name":"benzo(a)pyrene","range":"(0,030 – 100) μg/l"},{"name":"benzo(b)fluoranthene","range":"(0,030 – 100) μg/l"},{"name":"benzo(k)fluoranthene","range":"(0,030 – 100) μg/l"},{"name":"benzo(ghi)perylene","range":"(0,030 – 100) μg/l"},{"name":"indeno","range":"(1,2,3-cd)piren"},{"name":"(0,030 – 100) μg/l"},{"name":"acenaphthene","range":"(0,030 – 100) μg/l"},{"name":"acenaphthylene","range":"(0,030 – 100) μg/l"},{"name":"fluoranthene","range":"(0,030 – 100) μg/l"},{"name":"fluorene","range":"(0,030 – 100) μg/l"},{"name":"phenanthrene","range":"(0,030 – 100) μg/l"},{"name":"pyrene","range":"(0,030 – 100) μg/l"}],"search_en":"Water, Wastewater Concentration of polycyclic aromatic hydrocarbons Gas chromatography with mass spectrometry detection (GC-MS) naphthalene anthracene chrysene benzo(a)anthracene dibenzo(a,h)anthracene Range benzo(a)pyrene benzo(b)fluoranthene benzo(k)fluoranthene benzo(ghi)perylene indeno (0,030 – 100) μg/l acenaphthene acenaphthylene fluoranthene fluorene phenanthrene pyrene EFO/PB/14/A: 01.08.2022","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"萘","range":"(0,50 – 100) μg/l"},{"name":"蒽","range":"(0,030 – 100) μg/l"},{"name":"䓛","range":"(0,030 – 100) μg/l"},{"name":"苯并（a）蒽","range":"(0,030 – 100) μg/l"},{"name":"二苯并（a,h）蒽"},{"name":"范围","range":"(0,030 – 100) μg/l"},{"name":"苯并（a）芘","range":"(0,030 – 100) μg/l"},{"name":"苯并（b）荧蒽","range":"(0,030 – 100) μg/l"},{"name":"苯并（k）荧蒽","range":"(0,030 – 100) μg/l"},{"name":"苯并（ghi）苝","range":"(0,030 – 100) μg/l"},{"name":"茚","range":"(1,2,3-cd)piren"},{"name":"(0,030 – 100) μg/l"},{"name":"苊","range":"(0,030 – 100) μg/l"},{"name":"苊烯","range":"(0,030 – 100) μg/l"},{"name":"荧蒽","range":"(0,030 – 100) μg/l"},{"name":"芴","range":"(0,030 – 100) μg/l"},{"name":"菲","range":"(0,030 – 100) μg/l"},{"name":"芘","range":"(0,030 – 100) μg/l"}],"search_zh":"水、污水 多环芳烃浓度 气相色谱-质谱法（GC-MS） 萘 蒽 䓛 苯并（a）蒽 二苯并（a,h）蒽 范围 苯并（a）芘 苯并（b）荧蒽 苯并（k）荧蒽 苯并（ghi）苝 茚 苊 苊烯 荧蒽 芴 菲 芘 EFO/PB/14/A: 01.08.2022","technique_zh":"气相色谱-质谱法（GC-MS）","test_object_zh":"水、污水","methodology_zh":"多环芳烃浓度"},{"_id":"6a832b7f884ede9a1b2c56d5","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)","reference":"EFO/PB/14/A: 01.08.2022","norm_bases":["EFO/PB/14/A: 01.08.2022"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń) EFO/PB/14/A: 01.08.2022 Woda, Scieki Suma wielopierscieniowych weglowodorow aromatycznych (WWA) (z obliczen) EFO/PB/14/A: 01.08.2022","categories":["water"],"row_index":525,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of polycyclic aromatic hydrocarbons (PAH) (calculated)","search_en":"Water, Wastewater Sum of polycyclic aromatic hydrocarbons (PAH) (calculated) EFO/PB/14/A: 01.08.2022","test_object_en":"Water, Wastewater","search_zh":"水、污水 多环芳烃（PAH）总量（由计算得出） EFO/PB/14/A: 01.08.2022","test_object_zh":"水、污水","methodology_zh":"多环芳烃（PAH）总量（由计算得出）"},{"_id":"6a832b7f884ede9a1b2c56d6","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie pierwiastków","parameters":[{"name":"srebro","range":"(10 – 10000) μg/l"},{"name":"arsen","range":"(10 – 10000) μg/l"},{"name":"beryl","range":"(5 – 10000) μg/l"},{"name":"kadm","range":"(5 – 10000) μg/l"},{"name":"kobalt","range":"(10 – 10000) μg/l"},{"name":"molibden","range":"(10 – 10000) μg/l"},{"name":"antymon","range":"(10 – 10000) μg/l"},{"name":"selen","range":"(10 – 10000) μg/l"},{"name":"cyna","range":"(10 – 10000) μg/l"},{"name":"tytan","range":"(10 – 10000) μg/l"},{"name":"tal","range":"(5 – 10000) μg/l"},{"name":"uran","range":"(10 – 10000) μg/l"},{"name":"wanad","range":"(10 – 10000) μg/l"},{"name":"chrom","range":"(10 – 10000) μg/l"},{"name":"miedź","range":"(10 – 10000) μg/l"},{"name":"nikiel","range":"(10 – 10000) μg/l"},{"name":"ołów","range":"(10 – 10000) μg/l"},{"name":"glin","range":"(100 – 200000) μg/l"},{"name":"bor","range":"(500 – 200000) μg/l"},{"name":"bar","range":"(50 – 200000) μg/l"},{"name":"cynk","range":"(100 – 200000) μg/l"},{"name":"mangan","range":"(50 – 200000) μg/l"},{"name":"fosfor","range":"(100 – 200000) μg/l"},{"name":"rtęć","range":"(1 – 1000) μg/l"},{"name":"wapń","range":"(10000 – 1000000) μg/l"},{"name":"magnez","range":"(5000 – 1000000) μg/l"},{"name":"sód","range":"(10000 – 1000000) μg/l"},{"name":"potas","range":"(5000 – 1000000) μg/l"},{"name":"żelazo","range":"(100 – 100000) μg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nsrebro (10 – 10000) μg/l\narsen (10 – 10000) μg/l\nberyl (5 – 10000) μg/l\nkadm (5 – 10000) μg/l\nkobalt (10 – 10000) μg/l\nmolibden (10 – 10000) μg/l\nantymon (10 – 10000) μg/l\nselen (10 – 10000) μg/l\ncyna (10 – 10000) μg/l\ntytan (10 – 10000) μg/l\ntal (5 – 10000) μg/l\nuran (10 – 10000) μg/l\nwanad (10 – 10000) μg/l\nchrom (10 – 10000) μg/l\nmiedź (10 – 10000) μg/l\nnikiel (10 – 10000) μg/l\nołów (10 – 10000) μg/l\nglin (100 – 200000) μg/l\nbor (500 – 200000) μg/l\nbar (50 – 200000) μg/l\ncynk (100 – 200000) μg/l\nmangan (50 – 200000) μg/l\nfosfor (100 – 200000) μg/l\nrtęć (1 – 1000) μg/l\nwapń (10000 – 1000000) μg/l\nmagnez (5000 – 1000000) μg/l\nsód (10000 – 1000000) μg/l\npotas (5000 – 1000000) μg/l\nżelazo (100 – 100000) μg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie pierwiastków\nZakres:\nsrebro (10 – 10000) μg/l\narsen (10 – 10000) μg/l\nberyl (5 – 10000) μg/l\nkadm (5 – 10000) μg/l\nkobalt (10 – 10000) μg/l\nmolibden (10 – 10000) μg/l\nantymon (10 – 10000) μg/l\nselen (10 – 10000) μg/l\ncyna (10 – 10000) μg/l\ntytan (10 – 10000) μg/l\ntal (5 – 10000) μg/l\nuran (10 – 10000) μg/l\nwanad (10 – 10000) μg/l\nchrom (10 – 10000) μg/l\nmiedź (10 – 10000) μg/l\nnikiel (10 – 10000) μg/l\nołów (10 – 10000) μg/l\nglin (100 – 200000) μg/l\nbor (500 – 200000) μg/l\nbar (50 – 200000) μg/l\ncynk (100 – 200000) μg/l\nmangan (50 – 200000) μg/l\nfosfor (100 – 200000) μg/l\nrtęć (1 – 1000) μg/l\nwapń (10000 – 1000000) μg/l\nmagnez (5000 – 1000000) μg/l\nsód (10000 – 1000000) μg/l\npotas (5000 – 1000000) μg/l\nżelazo (100 – 100000) μg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Scieki Stezenie pierwiastkow\nZakres:\nsrebro (10 – 10000) μg/l\narsen (10 – 10000) μg/l\nberyl (5 – 10000) μg/l\nkadm (5 – 10000) μg/l\nkobalt (10 – 10000) μg/l\nmolibden (10 – 10000) μg/l\nantymon (10 – 10000) μg/l\nselen (10 – 10000) μg/l\ncyna (10 – 10000) μg/l\ntytan (10 – 10000) μg/l\ntal (5 – 10000) μg/l\nuran (10 – 10000) μg/l\nwanad (10 – 10000) μg/l\nchrom (10 – 10000) μg/l\nmiedz (10 – 10000) μg/l\nnikiel (10 – 10000) μg/l\nolow (10 – 10000) μg/l\nglin (100 – 200000) μg/l\nbor (500 – 200000) μg/l\nbar (50 – 200000) μg/l\ncynk (100 – 200000) μg/l\nmangan (50 – 200000) μg/l\nfosfor (100 – 200000) μg/l\nrtec (1 – 1000) μg/l\nwapn (10000 – 1000000) μg/l\nmagnez (5000 – 1000000) μg/l\nsod (10000 – 1000000) μg/l\npotas (5000 – 1000000) μg/l\nzelazo (100 – 100000) μg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["water","materials"],"row_index":526,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"silver","range":"(10 – 10000) μg/l"},{"name":"arsenic","range":"(10 – 10000) μg/l"},{"name":"beryllium","range":"(5 – 10000) μg/l"},{"name":"cadmium","range":"(5 – 10000) μg/l"},{"name":"cobalt","range":"(10 – 10000) μg/l"},{"name":"molybdenum","range":"(10 – 10000) μg/l"},{"name":"antimony","range":"(10 – 10000) μg/l"},{"name":"selenium","range":"(10 – 10000) μg/l"},{"name":"tin","range":"(10 – 10000) μg/l"},{"name":"titanium","range":"(10 – 10000) μg/l"},{"name":"thallium","range":"(5 – 10000) μg/l"},{"name":"uranium","range":"(10 – 10000) μg/l"},{"name":"vanadium","range":"(10 – 10000) μg/l"},{"name":"chromium","range":"(10 – 10000) μg/l"},{"name":"copper","range":"(10 – 10000) μg/l"},{"name":"nickel","range":"(10 – 10000) μg/l"},{"name":"lead","range":"(10 – 10000) μg/l"},{"name":"aluminium","range":"(100 – 200000) μg/l"},{"name":"boron","range":"(500 – 200000) μg/l"},{"name":"barium","range":"(50 – 200000) μg/l"},{"name":"zinc","range":"(100 – 200000) μg/l"},{"name":"manganese","range":"(50 – 200000) μg/l"},{"name":"phosphorus","range":"(100 – 200000) μg/l"},{"name":"mercury","range":"(1 – 1000) μg/l"},{"name":"calcium","range":"(10000 – 1000000) μg/l"},{"name":"magnesium","range":"(5000 – 1000000) μg/l"},{"name":"sodium","range":"(10000 – 1000000) μg/l"},{"name":"potassium","range":"(5000 – 1000000) μg/l"},{"name":"iron","range":"(100 – 100000) μg/l"}],"search_en":"Wastewater Element concentration Inductively coupled plasma mass spectrometry (ICP-MS) silver arsenic beryllium cadmium cobalt molybdenum antimony selenium tin titanium thallium uranium vanadium chromium copper nickel lead aluminium boron barium zinc manganese phosphorus mercury calcium magnesium sodium potassium iron PN-EN ISO 17294-2:2024-04","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Wastewater","methodology_zh":"元素浓度","parameters_zh":[{"name":"银","range":"(10 – 10000) μg/l"},{"name":"砷","range":"(10 – 10000) μg/l"},{"name":"铍","range":"(5 – 10000) μg/l"},{"name":"镉","range":"(5 – 10000) μg/l"},{"name":"钴","range":"(10 – 10000) μg/l"},{"name":"钼","range":"(10 – 10000) μg/l"},{"name":"锑","range":"(10 – 10000) μg/l"},{"name":"硒","range":"(10 – 10000) μg/l"},{"name":"锡","range":"(10 – 10000) μg/l"},{"name":"钛","range":"(10 – 10000) μg/l"},{"name":"铊","range":"(5 – 10000) μg/l"},{"name":"铀","range":"(10 – 10000) μg/l"},{"name":"钒","range":"(10 – 10000) μg/l"},{"name":"铬","range":"(10 – 10000) μg/l"},{"name":"铜","range":"(10 – 10000) μg/l"},{"name":"镍","range":"(10 – 10000) μg/l"},{"name":"铅","range":"(10 – 10000) μg/l"},{"name":"铝","range":"(100 – 200000) μg/l"},{"name":"硼","range":"(500 – 200000) μg/l"},{"name":"钡","range":"(50 – 200000) μg/l"},{"name":"锌","range":"(100 – 200000) μg/l"},{"name":"锰","range":"(50 – 200000) μg/l"},{"name":"磷","range":"(100 – 200000) μg/l"},{"name":"汞","range":"(1 – 1000) μg/l"},{"name":"钙","range":"(10000 – 1000000) μg/l"},{"name":"镁","range":"(5000 – 1000000) μg/l"},{"name":"钠","range":"(10000 – 1000000) μg/l"},{"name":"钾","range":"(5000 – 1000000) μg/l"},{"name":"铁","range":"(100 – 100000) μg/l"}],"search_zh":"污水 元素浓度 电感耦合等离子体质谱法（ICP-MS） 银 砷 铍 镉 钴 钼 锑 硒 锡 钛 铊 铀 钒 铬 铜 镍 铅 铝 硼 钡 锌 锰 磷 汞 钙 镁 钠 钾 铁 PN-EN ISO 17294-2:2024-04","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"污水"},{"_id":"6a832b7f884ede9a1b2c56d7","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie węglowodorów C6-C12, frakcja benzyn","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/l"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Stężenie węglowodorów C6-C12, frakcja benzyn\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PN-ISO 11423-1:2002","norm_bases":["PN-ISO 11423-1:2002"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie węglowodorów C6-C12, frakcja benzyn\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PN-ISO 11423-1:2002 Scieki Stezenie weglowodorow C6-C12, frakcja benzyn\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PN-ISO 11423-1:2002","categories":["water"],"row_index":527,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of C6-C12 hydrocarbons, gasoline fraction","parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/l"}],"search_en":"Wastewater Concentration of C6-C12 hydrocarbons, gasoline fraction Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) Range PN-ISO 11423-1:2002","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/l"}],"search_zh":"污水 顶空气相色谱-质谱法（HS-GC-MS） 范围 PN-ISO 11423-1:2002","test_object_zh":"污水","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）"},{"_id":"6a832b7f884ede9a1b2c56d8","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie lotnych węglowodorów aromatycznych","parameters":[{"name":"benzen","range":"(0,25 – 5000) μg/l"},{"name":"toluen","range":"(0,25 – 5000) μg/l"},{"name":"etylobenzen","range":"(0,25 – 5000) μg/l"},{"name":"m+p-ksylen","range":"(0,50 – 10000) μg/l"},{"name":"o-ksylen","range":"(0,25 – 5000) μg/l"},{"name":"styren","range":"(0,25 – 5000) μg/l"},{"name":"izopropylobenzen","range":"(0,25 – 5000) μg/l"},{"name":"n-propylobenzen","range":"(0,25 – 5000) μg/l"},{"name":"Zakres","range":"1,3,5-trimetylobenzen"},{"name":"Zakres","range":"(0,25 – 5000) μg/l"},{"name":"tert-butylobenzen","range":"(0,25 – 5000) μg/l"},{"name":"1,2,4-trimetylobenzen","range":"(0,25 – 5000) μg/l"},{"name":"sec-butylobenzen","range":"(0,25 – 5000) μg/l"},{"name":"4-izopropylotoluen","range":"(0,25 – 5000) μg/l"},{"name":"n-butylobenzen","range":"(0,25 – 5000) μg/l"},{"name":"naftalen","range":"(0,25 – 5000) μg/l"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Stężenie lotnych węglowodorów aromatycznych\nZakres:\nbenzen (0,25 – 5000) μg/l\ntoluen (0,25 – 5000) μg/l\netylobenzen (0,25 – 5000) μg/l\nm+p-ksylen (0,50 – 10000) μg/l\no-ksylen (0,25 – 5000) μg/l\nstyren (0,25 – 5000) μg/l\nizopropylobenzen (0,25 – 5000) μg/l\nn-propylobenzen (0,25 – 5000) μg/l\nZakres 1,3,5-trimetylobenzen\nZakres (0,25 – 5000) μg/l\ntert-butylobenzen (0,25 – 5000) μg/l\n1,2,4-trimetylobenzen (0,25 – 5000) μg/l\nsec-butylobenzen (0,25 – 5000) μg/l\n4-izopropylotoluen (0,25 – 5000) μg/l\nn-butylobenzen (0,25 – 5000) μg/l\nnaftalen (0,25 – 5000) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PN-ISO 11423-1:2002","norm_bases":["PN-ISO 11423-1:2002"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie lotnych węglowodorów aromatycznych\nZakres:\nbenzen (0,25 – 5000) μg/l\ntoluen (0,25 – 5000) μg/l\netylobenzen (0,25 – 5000) μg/l\nm+p-ksylen (0,50 – 10000) μg/l\no-ksylen (0,25 – 5000) μg/l\nstyren (0,25 – 5000) μg/l\nizopropylobenzen (0,25 – 5000) μg/l\nn-propylobenzen (0,25 – 5000) μg/l\nZakres 1,3,5-trimetylobenzen\nZakres (0,25 – 5000) μg/l\ntert-butylobenzen (0,25 – 5000) μg/l\n1,2,4-trimetylobenzen (0,25 – 5000) μg/l\nsec-butylobenzen (0,25 – 5000) μg/l\n4-izopropylotoluen (0,25 – 5000) μg/l\nn-butylobenzen (0,25 – 5000) μg/l\nnaftalen (0,25 – 5000) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PN-ISO 11423-1:2002 Scieki Stezenie lotnych weglowodorow aromatycznych\nZakres:\nbenzen (0,25 – 5000) μg/l\ntoluen (0,25 – 5000) μg/l\netylobenzen (0,25 – 5000) μg/l\nm+p-ksylen (0,50 – 10000) μg/l\no-ksylen (0,25 – 5000) μg/l\nstyren (0,25 – 5000) μg/l\nizopropylobenzen (0,25 – 5000) μg/l\nn-propylobenzen (0,25 – 5000) μg/l\nZakres 1,3,5-trimetylobenzen\nZakres (0,25 – 5000) μg/l\ntert-butylobenzen (0,25 – 5000) μg/l\n1,2,4-trimetylobenzen (0,25 – 5000) μg/l\nsec-butylobenzen (0,25 – 5000) μg/l\n4-izopropylotoluen (0,25 – 5000) μg/l\nn-butylobenzen (0,25 – 5000) μg/l\nnaftalen (0,25 – 5000) μg/l\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PN-ISO 11423-1:2002","categories":["water"],"row_index":528,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of volatile aromatic hydrocarbons","parameters_en":[{"name":"benzene","range":"(0,25 – 5000) μg/l"},{"name":"toluene","range":"(0,25 – 5000) μg/l"},{"name":"ethylbenzene","range":"(0,25 – 5000) μg/l"},{"name":"m+p-xylene","range":"(0,50 – 10000) μg/l"},{"name":"o-xylene","range":"(0,25 – 5000) μg/l"},{"name":"styrene","range":"(0,25 – 5000) μg/l"},{"name":"isopropylbenzene","range":"(0,25 – 5000) μg/l"},{"name":"n-propylbenzene","range":"(0,25 – 5000) μg/l"},{"name":"Range","range":"1,3,5-trimetylobenzen"},{"name":"Range","range":"(0,25 – 5000) μg/l"},{"name":"tert-butylbenzene","range":"(0,25 – 5000) μg/l"},{"name":"1,2,4-trimethylbenzene","range":"(0,25 – 5000) μg/l"},{"name":"sec-butylbenzene","range":"(0,25 – 5000) μg/l"},{"name":"4-isopropyltoluene","range":"(0,25 – 5000) μg/l"},{"name":"n-butylbenzene","range":"(0,25 – 5000) μg/l"},{"name":"naphthalene","range":"(0,25 – 5000) μg/l"}],"search_en":"Wastewater Concentration of volatile aromatic hydrocarbons Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) benzene toluene ethylbenzene m+p-xylene o-xylene styrene isopropylbenzene n-propylbenzene Range Range tert-butylbenzene 1,2,4-trimethylbenzene sec-butylbenzene 4-isopropyltoluene n-butylbenzene naphthalene PN-ISO 11423-1:2002","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Wastewater","parameters_zh":[{"name":"苯","range":"(0,25 – 5000) μg/l"},{"name":"甲苯","range":"(0,25 – 5000) μg/l"},{"name":"乙苯","range":"(0,25 – 5000) μg/l"},{"name":"间+对二甲苯","range":"(0,50 – 10000) μg/l"},{"name":"邻二甲苯","range":"(0,25 – 5000) μg/l"},{"name":"苯乙烯","range":"(0,25 – 5000) μg/l"},{"name":"异丙苯","range":"(0,25 – 5000) μg/l"},{"name":"正丙苯","range":"(0,25 – 5000) μg/l"},{"name":"范围","range":"1,3,5-trimetylobenzen"},{"name":"范围","range":"(0,25 – 5000) μg/l"},{"name":"tert-butylobenzen","range":"(0,25 – 5000) μg/l"},{"name":"1,2,4-三甲苯","range":"(0,25 – 5000) μg/l"},{"name":"仲丁苯","range":"(0,25 – 5000) μg/l"},{"name":"4-izopropylotoluen","range":"(0,25 – 5000) μg/l"},{"name":"正丁苯","range":"(0,25 – 5000) μg/l"},{"name":"萘","range":"(0,25 – 5000) μg/l"}],"search_zh":"污水 挥发性芳香烃浓度 顶空气相色谱-质谱法（HS-GC-MS） 苯 甲苯 乙苯 间+对二甲苯 邻二甲苯 苯乙烯 异丙苯 正丙苯 范围 范围 1,2,4-三甲苯 仲丁苯 正丁苯 萘 PN-ISO 11423-1:2002","test_object_zh":"污水","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）","methodology_zh":"挥发性芳香烃浓度"},{"_id":"6a832b7f884ede9a1b2c56d9","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie łatwo lotnych","parameters":[{"name":"chlorowcowych pochodnych"},{"name":"węglowodorów"},{"name":"dichlorodifluorometan"},{"name":"Zakres","range":"(0,25 – 5000) μg/l"},{"name":"chlorometan","range":"(0,25 – 5000) μg/l"},{"name":"chlorek winylu","range":"(0,25 – 5000) μg/l"},{"name":"bromometan","range":"(0,25 – 5000) μg/l"},{"name":"chloroetan","range":"(0,25 – 5000) μg/l"},{"name":"trichlorofluorometan","range":"(0,25 – 5000) μg/l"},{"name":"1,1-dichloroeten","range":"(0,25 – 5000) μg/l"},{"name":"dichlorometan","range":"(0,25 – 5000) μg/l"},{"name":"trans 1,2-dichloroeten","range":"(0,25 – 5000) μg/l"},{"name":"1,1-dichloroetan","range":"(0,25 – 5000) μg/l"},{"name":"2,2-dichloropropan","range":"(0,25 – 5000) μg/l"},{"name":"cis 1,2-dichloroeten","range":"(0,25 – 5000) μg/l"},{"name":"bromochlorometan","range":"(0,25 – 5000) μg/l"},{"name":"trichlorometan (chloroform)","range":"(0,25 – 5000) μg/l"},{"name":"1,1,1-trichloroetan","range":"(0,25 – 5000) μg/l"},{"name":"1,1-dichloropropen","range":"(0,25 – 5000) μg/l"},{"name":"tetrachlorometan","range":"(0,25 – 5000) μg/l"},{"name":"1,2-dichloroetan (EDC)","range":"(0,25 – 5000) μg/l"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Stężenie łatwo lotnych\nZakres:\nchlorowcowych pochodnych\nwęglowodorów\ndichlorodifluorometan\nZakres (0,25 – 5000) μg/l\nchlorometan (0,25 – 5000) μg/l\nchlorek winylu (0,25 – 5000) μg/l\nbromometan (0,25 – 5000) μg/l\nchloroetan (0,25 – 5000) μg/l\ntrichlorofluorometan (0,25 – 5000) μg/l\n1,1-dichloroeten (0,25 – 5000) μg/l\ndichlorometan (0,25 – 5000) μg/l\ntrans 1,2-dichloroeten (0,25 – 5000) μg/l\n1,1-dichloroetan (0,25 – 5000) μg/l\n2,2-dichloropropan (0,25 – 5000) μg/l\ncis 1,2-dichloroeten (0,25 – 5000) μg/l\nbromochlorometan (0,25 – 5000) μg/l\ntrichlorometan (chloroform) (0,25 – 5000) μg/l\n1,1,1-trichloroetan (0,25 – 5000) μg/l\n1,1-dichloropropen (0,25 – 5000) μg/l\ntetrachlorometan (0,25 – 5000) μg/l\n1,2-dichloroetan (EDC) (0,25 – 5000) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie łatwo lotnych\nZakres:\nchlorowcowych pochodnych\nwęglowodorów\ndichlorodifluorometan\nZakres (0,25 – 5000) μg/l\nchlorometan (0,25 – 5000) μg/l\nchlorek winylu (0,25 – 5000) μg/l\nbromometan (0,25 – 5000) μg/l\nchloroetan (0,25 – 5000) μg/l\ntrichlorofluorometan (0,25 – 5000) μg/l\n1,1-dichloroeten (0,25 – 5000) μg/l\ndichlorometan (0,25 – 5000) μg/l\ntrans 1,2-dichloroeten (0,25 – 5000) μg/l\n1,1-dichloroetan (0,25 – 5000) μg/l\n2,2-dichloropropan (0,25 – 5000) μg/l\ncis 1,2-dichloroeten (0,25 – 5000) μg/l\nbromochlorometan (0,25 – 5000) μg/l\ntrichlorometan (chloroform) (0,25 – 5000) μg/l\n1,1,1-trichloroetan (0,25 – 5000) μg/l\n1,1-dichloropropen (0,25 – 5000) μg/l\ntetrachlorometan (0,25 – 5000) μg/l\n1,2-dichloroetan (EDC) (0,25 – 5000) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PN-EN ISO 10301:2002 Scieki Stezenie latwo lotnych\nZakres:\nchlorowcowych pochodnych\nweglowodorow\ndichlorodifluorometan\nZakres (0,25 – 5000) μg/l\nchlorometan (0,25 – 5000) μg/l\nchlorek winylu (0,25 – 5000) μg/l\nbromometan (0,25 – 5000) μg/l\nchloroetan (0,25 – 5000) μg/l\ntrichlorofluorometan (0,25 – 5000) μg/l\n1,1-dichloroeten (0,25 – 5000) μg/l\ndichlorometan (0,25 – 5000) μg/l\ntrans 1,2-dichloroeten (0,25 – 5000) μg/l\n1,1-dichloroetan (0,25 – 5000) μg/l\n2,2-dichloropropan (0,25 – 5000) μg/l\ncis 1,2-dichloroeten (0,25 – 5000) μg/l\nbromochlorometan (0,25 – 5000) μg/l\ntrichlorometan (chloroform) (0,25 – 5000) μg/l\n1,1,1-trichloroetan (0,25 – 5000) μg/l\n1,1-dichloropropen (0,25 – 5000) μg/l\ntetrachlorometan (0,25 – 5000) μg/l\n1,2-dichloroetan (EDC) (0,25 – 5000) μg/l\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PN-EN ISO 10301:2002","categories":["water"],"row_index":529,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Stężenie łatwo lotnych","parameters_en":[{"name":"halogenated derivatives"},{"name":"hydrocarbons"},{"name":"dichlorodifluoromethane"},{"name":"Range","range":"(0,25 – 5000) μg/l"},{"name":"chloromethane","range":"(0,25 – 5000) μg/l"},{"name":"vinyl chloride","range":"(0,25 – 5000) μg/l"},{"name":"bromomethane","range":"(0,25 – 5000) μg/l"},{"name":"chloroethane","range":"(0,25 – 5000) μg/l"},{"name":"trichlorofluoromethane","range":"(0,25 – 5000) μg/l"},{"name":"1,1-dichloroethene","range":"(0,25 – 5000) μg/l"},{"name":"dichloromethane","range":"(0,25 – 5000) μg/l"},{"name":"trans 1,2-dichloroethene","range":"(0,25 – 5000) μg/l"},{"name":"1,1-dichloroethane","range":"(0,25 – 5000) μg/l"},{"name":"2,2-dichloropropane","range":"(0,25 – 5000) μg/l"},{"name":"cis 1,2-dichloroethene","range":"(0,25 – 5000) μg/l"},{"name":"bromochloromethane","range":"(0,25 – 5000) μg/l"},{"name":"trichloromethane (chloroform)","range":"(0,25 – 5000) μg/l"},{"name":"1,1,1-trichloroethane","range":"(0,25 – 5000) μg/l"},{"name":"1,1-dichloropropene","range":"(0,25 – 5000) μg/l"},{"name":"tetrachloromethane","range":"(0,25 – 5000) μg/l"},{"name":"1,2-dichloroethane (EDC)","range":"(0,25 – 5000) μg/l"}],"search_en":"Wastewater Stężenie łatwo lotnych Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) halogenated derivatives hydrocarbons dichlorodifluoromethane Range chloromethane vinyl chloride bromomethane chloroethane trichlorofluoromethane 1,1-dichloroethene dichloromethane trans 1,2-dichloroethene 1,1-dichloroethane 2,2-dichloropropane cis 1,2-dichloroethene bromochloromethane trichloromethane (chloroform) 1,1,1-trichloroethane 1,1-dichloropropene tetrachloromethane 1,2-dichloroethane (EDC) PN-EN ISO 10301:2002","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Wastewater","parameters_zh":[{"name":"chlorowcowych pochodnych"},{"name":"węglowodorów"},{"name":"dichlorodifluorometan"},{"name":"范围","range":"(0,25 – 5000) μg/l"},{"name":"chlorometan","range":"(0,25 – 5000) μg/l"},{"name":"氯乙烯","range":"(0,25 – 5000) μg/l"},{"name":"溴甲烷","range":"(0,25 – 5000) μg/l"},{"name":"氯乙烷","range":"(0,25 – 5000) μg/l"},{"name":"trichlorofluorometan","range":"(0,25 – 5000) μg/l"},{"name":"1,1-二氯乙烯","range":"(0,25 – 5000) μg/l"},{"name":"二氯甲烷","range":"(0,25 – 5000) μg/l"},{"name":"trans 1,2-dichloroeten","range":"(0,25 – 5000) μg/l"},{"name":"1,1-二氯乙烷","range":"(0,25 – 5000) μg/l"},{"name":"2,2-二氯丙烷","range":"(0,25 – 5000) μg/l"},{"name":"cis 1,2-dichloroeten","range":"(0,25 – 5000) μg/l"},{"name":"溴氯甲烷","range":"(0,25 – 5000) μg/l"},{"name":"三氯甲烷（氯仿）","range":"(0,25 – 5000) μg/l"},{"name":"1,1,1-三氯乙烷","range":"(0,25 – 5000) μg/l"},{"name":"1,1-二氯丙烯","range":"(0,25 – 5000) μg/l"},{"name":"四氯化碳","range":"(0,25 – 5000) μg/l"},{"name":"1,2-dichloroetan (EDC)","range":"(0,25 – 5000) μg/l"}],"search_zh":"污水 顶空气相色谱-质谱法（HS-GC-MS） 范围 氯乙烯 溴甲烷 氯乙烷 1,1-二氯乙烯 二氯甲烷 1,1-二氯乙烷 2,2-二氯丙烷 溴氯甲烷 三氯甲烷（氯仿） 1,1,1-三氯乙烷 1,1-二氯丙烯 四氯化碳 PN-EN ISO 10301:2002","test_object_zh":"污水","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）"},{"_id":"6a832b7f884ede9a1b2c56da","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie łatwo lotnych","parameters":[{"name":"chlorowcowych pochodnych"},{"name":"węglowodorów"},{"name":"trichloroeten (TRI)","range":"(0,25 – 5000) μg/l"},{"name":"Zakres","range":"1,2-dichloropropan (0,25 – 5000) μg/l"},{"name":"dibromometan","range":"(0,25 – 5000) μg/l"},{"name":"bromodichlorometan","range":"(0,25 – 5000) μg/l"},{"name":"cis 1,3-dichloropropen","range":"(0,25 – 5000) μg/l"},{"name":"trans 1,3-dichloropropen","range":"(0,25 – 5000) μg/l"},{"name":"1,1,2-trichloroetan","range":"(0,25 – 5000) μg/l"},{"name":"1,3-dichloropropan","range":"(0,25 – 5000) μg/l"},{"name":"tetrachloroeten (PER)","range":"(0,25 – 5000) μg/l"},{"name":"dibromochlorometan","range":"(0,25 – 5000) μg/l"},{"name":"1,2-dibromoetan","range":"(0,25 – 5000) μg/l"},{"name":"chlorobenzen","range":"(0,25 – 5000) μg/l"},{"name":"1,1,1,2-tetrachloroetan","range":"(0,25 – 5000) μg/l"},{"name":"tribromometan (bromoform)","range":"(0,25 – 5000) μg/l"},{"name":"1,1,2,2-tetrachloroetan","range":"(0,25 – 5000) μg/l"},{"name":"bromobenzen","range":"(0,25 – 5000) μg/l"},{"name":"1,2,3-trichloropropan","range":"(0,25 – 5000) μg/l"},{"name":"2-chlorotoluen","range":"(0,25 – 5000) μg/l"},{"name":"4-chlorotoluen","range":"(0,25 – 5000) μg/l"},{"name":"1,3-dichlorobenzen","range":"(0,25 – 5000) μg/l"},{"name":"1,4-dichlorobenzen","range":"(0,25 – 5000) μg/l"},{"name":"1,2-dichlorobenzen","range":"(0,25 – 5000) μg/l"},{"name":"1,2-dibromo-3-chloropropan","range":"(0,25 – 5000) μg/l"},{"name":"1,2,4-trichlorobenzen","range":"(0,25 – 5000) μg/l"},{"name":"heksachlorobutadien (HCBD)","range":"(0,25 – 5000) μg/l"},{"name":"1,2,3-trichlorobenzen","range":"(0,25 – 5000) μg/l"},{"name":"1,3,5-trichlorobenzen","range":"(0,25 – 5000) μg/l"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Stężenie łatwo lotnych\nZakres:\nchlorowcowych pochodnych\nwęglowodorów\ntrichloroeten (TRI) (0,25 – 5000) μg/l\nZakres 1,2-dichloropropan (0,25 – 5000) μg/l\ndibromometan (0,25 – 5000) μg/l\nbromodichlorometan (0,25 – 5000) μg/l\ncis 1,3-dichloropropen (0,25 – 5000) μg/l\ntrans 1,3-dichloropropen (0,25 – 5000) μg/l\n1,1,2-trichloroetan (0,25 – 5000) μg/l\n1,3-dichloropropan (0,25 – 5000) μg/l\ntetrachloroeten (PER) (0,25 – 5000) μg/l\ndibromochlorometan (0,25 – 5000) μg/l\n1,2-dibromoetan (0,25 – 5000) μg/l\nchlorobenzen (0,25 – 5000) μg/l\n1,1,1,2-tetrachloroetan (0,25 – 5000) μg/l\ntribromometan (bromoform) (0,25 – 5000) μg/l\n1,1,2,2-tetrachloroetan (0,25 – 5000) μg/l\nbromobenzen (0,25 – 5000) μg/l\n1,2,3-trichloropropan (0,25 – 5000) μg/l\n2-chlorotoluen (0,25 – 5000) μg/l\n4-chlorotoluen (0,25 – 5000) μg/l\n1,3-dichlorobenzen (0,25 – 5000) μg/l\n1,4-dichlorobenzen (0,25 – 5000) μg/l\n1,2-dichlorobenzen (0,25 – 5000) μg/l\n1,2-dibromo-3-chloropropan (0,25 – 5000) μg/l\n1,2,4-trichlorobenzen (0,25 – 5000) μg/l\nheksachlorobutadien (HCBD) (0,25 – 5000) μg/l\n1,2,3-trichlorobenzen (0,25 – 5000) μg/l\n1,3,5-trichlorobenzen (0,25 – 5000) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie łatwo lotnych\nZakres:\nchlorowcowych pochodnych\nwęglowodorów\ntrichloroeten (TRI) (0,25 – 5000) μg/l\nZakres 1,2-dichloropropan (0,25 – 5000) μg/l\ndibromometan (0,25 – 5000) μg/l\nbromodichlorometan (0,25 – 5000) μg/l\ncis 1,3-dichloropropen (0,25 – 5000) μg/l\ntrans 1,3-dichloropropen (0,25 – 5000) μg/l\n1,1,2-trichloroetan (0,25 – 5000) μg/l\n1,3-dichloropropan (0,25 – 5000) μg/l\ntetrachloroeten (PER) (0,25 – 5000) μg/l\ndibromochlorometan (0,25 – 5000) μg/l\n1,2-dibromoetan (0,25 – 5000) μg/l\nchlorobenzen (0,25 – 5000) μg/l\n1,1,1,2-tetrachloroetan (0,25 – 5000) μg/l\ntribromometan (bromoform) (0,25 – 5000) μg/l\n1,1,2,2-tetrachloroetan (0,25 – 5000) μg/l\nbromobenzen (0,25 – 5000) μg/l\n1,2,3-trichloropropan (0,25 – 5000) μg/l\n2-chlorotoluen (0,25 – 5000) μg/l\n4-chlorotoluen (0,25 – 5000) μg/l\n1,3-dichlorobenzen (0,25 – 5000) μg/l\n1,4-dichlorobenzen (0,25 – 5000) μg/l\n1,2-dichlorobenzen (0,25 – 5000) μg/l\n1,2-dibromo-3-chloropropan (0,25 – 5000) μg/l\n1,2,4-trichlorobenzen (0,25 – 5000) μg/l\nheksachlorobutadien (HCBD) (0,25 – 5000) μg/l\n1,2,3-trichlorobenzen (0,25 – 5000) μg/l\n1,3,5-trichlorobenzen (0,25 – 5000) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PN-EN ISO 10301:2002 Scieki Stezenie latwo lotnych\nZakres:\nchlorowcowych pochodnych\nweglowodorow\ntrichloroeten (TRI) (0,25 – 5000) μg/l\nZakres 1,2-dichloropropan (0,25 – 5000) μg/l\ndibromometan (0,25 – 5000) μg/l\nbromodichlorometan (0,25 – 5000) μg/l\ncis 1,3-dichloropropen (0,25 – 5000) μg/l\ntrans 1,3-dichloropropen (0,25 – 5000) μg/l\n1,1,2-trichloroetan (0,25 – 5000) μg/l\n1,3-dichloropropan (0,25 – 5000) μg/l\ntetrachloroeten (PER) (0,25 – 5000) μg/l\ndibromochlorometan (0,25 – 5000) μg/l\n1,2-dibromoetan (0,25 – 5000) μg/l\nchlorobenzen (0,25 – 5000) μg/l\n1,1,1,2-tetrachloroetan (0,25 – 5000) μg/l\ntribromometan (bromoform) (0,25 – 5000) μg/l\n1,1,2,2-tetrachloroetan (0,25 – 5000) μg/l\nbromobenzen (0,25 – 5000) μg/l\n1,2,3-trichloropropan (0,25 – 5000) μg/l\n2-chlorotoluen (0,25 – 5000) μg/l\n4-chlorotoluen (0,25 – 5000) μg/l\n1,3-dichlorobenzen (0,25 – 5000) μg/l\n1,4-dichlorobenzen (0,25 – 5000) μg/l\n1,2-dichlorobenzen (0,25 – 5000) μg/l\n1,2-dibromo-3-chloropropan (0,25 – 5000) μg/l\n1,2,4-trichlorobenzen (0,25 – 5000) μg/l\nheksachlorobutadien (HCBD) (0,25 – 5000) μg/l\n1,2,3-trichlorobenzen (0,25 – 5000) μg/l\n1,3,5-trichlorobenzen (0,25 – 5000) μg/l\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PN-EN ISO 10301:2002","categories":["water"],"row_index":530,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Stężenie łatwo lotnych","parameters_en":[{"name":"halogenated derivatives"},{"name":"hydrocarbons"},{"name":"trichloroethene (TRI)","range":"(0,25 – 5000) μg/l"},{"name":"Range","range":"1,2-dichloropropan (0,25 – 5000) μg/l"},{"name":"dibromomethane","range":"(0,25 – 5000) μg/l"},{"name":"bromodichloromethane","range":"(0,25 – 5000) μg/l"},{"name":"cis 1,3-dichloropropene","range":"(0,25 – 5000) μg/l"},{"name":"trans 1,3-dichloropropene","range":"(0,25 – 5000) μg/l"},{"name":"1,1,2-trichloroethane","range":"(0,25 – 5000) μg/l"},{"name":"1,3-dichloropropane","range":"(0,25 – 5000) μg/l"},{"name":"tetrachloroethene (PER)","range":"(0,25 – 5000) μg/l"},{"name":"dibromochloromethane","range":"(0,25 – 5000) μg/l"},{"name":"1,2-dibromoethane","range":"(0,25 – 5000) μg/l"},{"name":"chlorobenzene","range":"(0,25 – 5000) μg/l"},{"name":"1,1,1,2-tetrachloroethane","range":"(0,25 – 5000) μg/l"},{"name":"tribromomethane (bromoform)","range":"(0,25 – 5000) μg/l"},{"name":"1,1,2,2-tetrachloroethane","range":"(0,25 – 5000) μg/l"},{"name":"bromobenzene","range":"(0,25 – 5000) μg/l"},{"name":"1,2,3-trichloropropane","range":"(0,25 – 5000) μg/l"},{"name":"2-chlorotoluene","range":"(0,25 – 5000) μg/l"},{"name":"4-chlorotoluene","range":"(0,25 – 5000) μg/l"},{"name":"1,3-dichlorobenzene","range":"(0,25 – 5000) μg/l"},{"name":"1,4-dichlorobenzene","range":"(0,25 – 5000) μg/l"},{"name":"1,2-dichlorobenzene","range":"(0,25 – 5000) μg/l"},{"name":"1,2-dibromo-3-chloropropane","range":"(0,25 – 5000) μg/l"},{"name":"1,2,4-trichlorobenzene","range":"(0,25 – 5000) μg/l"},{"name":"hexachlorobutadiene (HCBD)","range":"(0,25 – 5000) μg/l"},{"name":"1,2,3-trichlorobenzene","range":"(0,25 – 5000) μg/l"},{"name":"1,3,5-trichlorobenzene","range":"(0,25 – 5000) μg/l"}],"search_en":"Wastewater Stężenie łatwo lotnych Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) halogenated derivatives hydrocarbons trichloroethene (TRI) Range dibromomethane bromodichloromethane cis 1,3-dichloropropene trans 1,3-dichloropropene 1,1,2-trichloroethane 1,3-dichloropropane tetrachloroethene (PER) dibromochloromethane 1,2-dibromoethane chlorobenzene 1,1,1,2-tetrachloroethane tribromomethane (bromoform) 1,1,2,2-tetrachloroethane bromobenzene 1,2,3-trichloropropane 2-chlorotoluene 4-chlorotoluene 1,3-dichlorobenzene 1,4-dichlorobenzene 1,2-dichlorobenzene 1,2-dibromo-3-chloropropane 1,2,4-trichlorobenzene hexachlorobutadiene (HCBD) 1,2,3-trichlorobenzene 1,3,5-trichlorobenzene PN-EN ISO 10301:2002","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Wastewater","parameters_zh":[{"name":"chlorowcowych pochodnych"},{"name":"węglowodorów"},{"name":"trichloroeten (TRI)","range":"(0,25 – 5000) μg/l"},{"name":"范围","range":"1,2-dichloropropan (0,25 – 5000) μg/l"},{"name":"二溴甲烷","range":"(0,25 – 5000) μg/l"},{"name":"一溴二氯甲烷","range":"(0,25 – 5000) μg/l"},{"name":"cis 1,3-dichloropropen","range":"(0,25 – 5000) μg/l"},{"name":"trans 1,3-dichloropropen","range":"(0,25 – 5000) μg/l"},{"name":"1,1,2-三氯乙烷","range":"(0,25 – 5000) μg/l"},{"name":"1,3-二氯丙烷","range":"(0,25 – 5000) μg/l"},{"name":"tetrachloroeten (PER)","range":"(0,25 – 5000) μg/l"},{"name":"二溴一氯甲烷","range":"(0,25 – 5000) μg/l"},{"name":"1,2-二溴乙烷","range":"(0,25 – 5000) μg/l"},{"name":"氯苯","range":"(0,25 – 5000) μg/l"},{"name":"1,1,1,2-四氯乙烷","range":"(0,25 – 5000) μg/l"},{"name":"三溴甲烷（溴仿）","range":"(0,25 – 5000) μg/l"},{"name":"1,1,2,2-四氯乙烷","range":"(0,25 – 5000) μg/l"},{"name":"溴苯","range":"(0,25 – 5000) μg/l"},{"name":"1,2,3-三氯丙烷","range":"(0,25 – 5000) μg/l"},{"name":"2-chlorotoluen","range":"(0,25 – 5000) μg/l"},{"name":"4-chlorotoluen","range":"(0,25 – 5000) μg/l"},{"name":"1,3-二氯苯","range":"(0,25 – 5000) μg/l"},{"name":"1,4-二氯苯","range":"(0,25 – 5000) μg/l"},{"name":"1,2-二氯苯","range":"(0,25 – 5000) μg/l"},{"name":"1,2-二溴-3-氯丙烷","range":"(0,25 – 5000) μg/l"},{"name":"1,2,4-三氯苯","range":"(0,25 – 5000) μg/l"},{"name":"heksachlorobutadien (HCBD)","range":"(0,25 – 5000) μg/l"},{"name":"1,2,3-三氯苯","range":"(0,25 – 5000) μg/l"},{"name":"1,3,5-三氯苯","range":"(0,25 – 5000) μg/l"}],"search_zh":"污水 顶空气相色谱-质谱法（HS-GC-MS） 范围 二溴甲烷 一溴二氯甲烷 1,1,2-三氯乙烷 1,3-二氯丙烷 二溴一氯甲烷 1,2-二溴乙烷 氯苯 1,1,1,2-四氯乙烷 三溴甲烷（溴仿） 1,1,2,2-四氯乙烷 溴苯 1,2,3-三氯丙烷 1,3-二氯苯 1,4-二氯苯 1,2-二氯苯 1,2-二溴-3-氯丙烷 1,2,4-三氯苯 1,2,3-三氯苯 1,3,5-三氯苯 PN-EN ISO 10301:2002","test_object_zh":"污水","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）"},{"_id":"6a832b7f884ede9a1b2c56db","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Ścieki","methodology":"Trichlorobenzen (TCB) jako suma trzech izomerów (1,2,3-TCB + 1,2,4-TCB + 1,2,5-TCB) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Trichlorobenzen (TCB) jako suma trzech izomerów (1,2,3-TCB + 1,2,4-TCB + 1,2,5-TCB) (z obliczeń)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Trichlorobenzen (TCB) jako suma trzech izomerów (1,2,3-TCB + 1,2,4-TCB + 1,2,5-TCB) (z obliczeń) PN-EN ISO 10301:2002 Scieki Trichlorobenzen (TCB) jako suma trzech izomerow (1,2,3-TCB + 1,2,4-TCB + 1,2,5-TCB) (z obliczen) PN-EN ISO 10301:2002","categories":["water"],"row_index":531,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Trichlorobenzene (TCB) as the sum of three isomers (1,2,3-TCB + 1,2,4-TCB + 1,2,5-TCB) (calculated)","search_en":"Wastewater Trichlorobenzene (TCB) as the sum of three isomers (1,2,3-TCB + 1,2,4-TCB + 1,2,5-TCB) (calculated) PN-EN ISO 10301:2002","test_object_en":"Wastewater","search_zh":"污水 PN-EN ISO 10301:2002","test_object_zh":"污水"},{"_id":"6a832b7f884ede9a1b2c56dc","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Oznaczanie składu morfologicznego i sitowego","parameters":[{"name":"Zakres","range":"(0,1 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Oznaczanie składu morfologicznego i sitowego\nZakres (0,1 – 99,9) %\nMetoda wagowa","reference":"DIN 19747: 2009-07","norm_bases":["DIN 19747: 2009-07"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Oznaczanie składu morfologicznego i sitowego\nZakres (0,1 – 99,9) %\nMetoda wagowa DIN 19747: 2009-07 Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Oznaczanie skladu morfologicznego i sitowego\nZakres (0,1 – 99,9) %\nMetoda wagowa DIN 19747: 2009-07","categories":["environment"],"row_index":532,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Determination of morphological and sieve composition","parameters_en":[{"name":"Range","range":"(0,1 – 99,9) %"}],"search_en":"Determination of morphological and sieve composition Gravimetric method Range DIN 19747: 2009-07","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,1 – 99,9) %"}],"search_zh":"重量法 范围 DIN 19747: 2009-07","technique_zh":"重量法"},{"_id":"6a832b7f884ede9a1b2c56dd","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość polichlorowanych bifenyli","parameters":[{"name":"PCB 28","range":"(0,0020 – 10) mg/kg"},{"name":"PCB 52","range":"(0,0020 – 10) mg/kg"},{"name":"PCB 101","range":"(0,0020 – 10) mg/kg"},{"name":"PCB 118","range":"(0,0020 – 10) mg/kg"},{"name":"PCB 138","range":"(0,0020 – 10) mg/kg"},{"name":"PCB 153","range":"(0,0020 – 10) mg/kg"},{"name":"PCB 180","range":"(0,0020 – 10) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość polichlorowanych bifenyli\nZakres:\nPCB 28 (0,0020 – 10) mg/kg\nPCB 52 (0,0020 – 10) mg/kg\nPCB 101 (0,0020 – 10) mg/kg\nPCB 118 (0,0020 – 10) mg/kg\nPCB 138 (0,0020 – 10) mg/kg\nPCB 153 (0,0020 – 10) mg/kg\nPCB 180 (0,0020 – 10) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PN-EN 17322:2021-01","norm_bases":["PN-EN 17322:2021-01"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość polichlorowanych bifenyli\nZakres:\nPCB 28 (0,0020 – 10) mg/kg\nPCB 52 (0,0020 – 10) mg/kg\nPCB 101 (0,0020 – 10) mg/kg\nPCB 118 (0,0020 – 10) mg/kg\nPCB 138 (0,0020 – 10) mg/kg\nPCB 153 (0,0020 – 10) mg/kg\nPCB 180 (0,0020 – 10) mg/kg\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PN-EN 17322:2021-01 Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc polichlorowanych bifenyli\nZakres:\nPCB 28 (0,0020 – 10) mg/kg\nPCB 52 (0,0020 – 10) mg/kg\nPCB 101 (0,0020 – 10) mg/kg\nPCB 118 (0,0020 – 10) mg/kg\nPCB 138 (0,0020 – 10) mg/kg\nPCB 153 (0,0020 – 10) mg/kg\nPCB 180 (0,0020 – 10) mg/kg\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PN-EN 17322:2021-01","categories":["environment"],"row_index":533,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polychlorinated biphenyl content","parameters_en":[{"name":"PCB 28","range":"(0,0020 – 10) mg/kg"},{"name":"PCB 52","range":"(0,0020 – 10) mg/kg"},{"name":"PCB 101","range":"(0,0020 – 10) mg/kg"},{"name":"PCB 118","range":"(0,0020 – 10) mg/kg"},{"name":"PCB 138","range":"(0,0020 – 10) mg/kg"},{"name":"PCB 153","range":"(0,0020 – 10) mg/kg"},{"name":"PCB 180","range":"(0,0020 – 10) mg/kg"}],"search_en":"Polychlorinated biphenyl content Gas chromatography with mass spectrometry detection (GC-MS) PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 PN-EN 17322:2021-01","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","search_zh":"多氯联苯含量 气相色谱-质谱法（GC-MS） PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 PN-EN 17322:2021-01","technique_zh":"气相色谱-质谱法（GC-MS）","parameters_zh":[{"name":"PCB 28","range":"(0,0020 – 10) mg/kg"},{"name":"PCB 52","range":"(0,0020 – 10) mg/kg"},{"name":"PCB 101","range":"(0,0020 – 10) mg/kg"},{"name":"PCB 118","range":"(0,0020 – 10) mg/kg"},{"name":"PCB 138","range":"(0,0020 – 10) mg/kg"},{"name":"PCB 153","range":"(0,0020 – 10) mg/kg"},{"name":"PCB 180","range":"(0,0020 – 10) mg/kg"}],"methodology_zh":"多氯联苯含量"},{"_id":"6a832b7f884ede9a1b2c56de","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Suma polichlorowanych bifenyli (PCBs) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma polichlorowanych bifenyli (PCBs) (z obliczeń)","reference":"PN-EN 17322:2021-01","norm_bases":["PN-EN 17322:2021-01"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Suma polichlorowanych bifenyli (PCBs) (z obliczeń) PN-EN 17322:2021-01 Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Suma polichlorowanych bifenyli (PCBs) (z obliczen) PN-EN 17322:2021-01","categories":["environment"],"row_index":534,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of polychlorinated biphenyls (PCBs) (calculated)","search_en":"Sum of polychlorinated biphenyls (PCBs) (calculated) PN-EN 17322:2021-01"},{"_id":"6a832b7f884ede9a1b2c56df","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08, Wyciągi wodne przygotowane przez, Laboratorium Siedziba Główna; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość pierwiastków","parameters":[{"name":"antymon","range":"(0,0005 – 10) mg/l"},{"name":"arsen","range":"(0,0005 – 10) mg/l"},{"name":"bar","range":"(0,001 – 10) mg/l"},{"name":"chrom","range":"(0,001 – 10) mg/l"},{"name":"cynk","range":"(0,01 – 20) mg/l"},{"name":"kadm","range":"(0,0005 – 10) mg/l"},{"name":"miedź","range":"(0,001 – 10) mg/l"},{"name":"molibden","range":"(0,0005 – 10) mg/l"},{"name":"nikiel","range":"(0,001 – 10) mg/l"},{"name":"ołów","range":"(0,001 – 10) mg/l"},{"name":"rtęć","range":"(0,0002 – 1) mg/l"},{"name":"selen","range":"(0,0005 – 10) mg/l"},{"name":"tal","range":"(0,0005 – 10) mg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nantymon (0,0005 – 10) mg/l\narsen (0,0005 – 10) mg/l\nbar (0,001 – 10) mg/l\nchrom (0,001 – 10) mg/l\ncynk (0,01 – 20) mg/l\nkadm (0,0005 – 10) mg/l\nmiedź (0,001 – 10) mg/l\nmolibden (0,0005 – 10) mg/l\nnikiel (0,001 – 10) mg/l\nołów (0,001 – 10) mg/l\nrtęć (0,0002 – 1) mg/l\nselen (0,0005 – 10) mg/l\ntal (0,0005 – 10) mg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08, Wyciągi wodne przygotowane przez, Laboratorium Siedziba Główna; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość pierwiastków\nZakres:\nantymon (0,0005 – 10) mg/l\narsen (0,0005 – 10) mg/l\nbar (0,001 – 10) mg/l\nchrom (0,001 – 10) mg/l\ncynk (0,01 – 20) mg/l\nkadm (0,0005 – 10) mg/l\nmiedź (0,001 – 10) mg/l\nmolibden (0,0005 – 10) mg/l\nnikiel (0,001 – 10) mg/l\nołów (0,001 – 10) mg/l\nrtęć (0,0002 – 1) mg/l\nselen (0,0005 – 10) mg/l\ntal (0,0005 – 10) mg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Gleba, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08, Wyciagi wodne przygotowane przez, Laboratorium Siedziba Glowna; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc pierwiastkow\nZakres:\nantymon (0,0005 – 10) mg/l\narsen (0,0005 – 10) mg/l\nbar (0,001 – 10) mg/l\nchrom (0,001 – 10) mg/l\ncynk (0,01 – 20) mg/l\nkadm (0,0005 – 10) mg/l\nmiedz (0,001 – 10) mg/l\nmolibden (0,0005 – 10) mg/l\nnikiel (0,001 – 10) mg/l\nolow (0,001 – 10) mg/l\nrtec (0,0002 – 1) mg/l\nselen (0,0005 – 10) mg/l\ntal (0,0005 – 10) mg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["environment","materials"],"row_index":535,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","parameters_en":[{"name":"antimony","range":"(0,0005 – 10) mg/l"},{"name":"arsenic","range":"(0,0005 – 10) mg/l"},{"name":"barium","range":"(0,001 – 10) mg/l"},{"name":"chromium","range":"(0,001 – 10) mg/l"},{"name":"zinc","range":"(0,01 – 20) mg/l"},{"name":"cadmium","range":"(0,0005 – 10) mg/l"},{"name":"copper","range":"(0,001 – 10) mg/l"},{"name":"molybdenum","range":"(0,0005 – 10) mg/l"},{"name":"nickel","range":"(0,001 – 10) mg/l"},{"name":"lead","range":"(0,001 – 10) mg/l"},{"name":"mercury","range":"(0,0002 – 1) mg/l"},{"name":"selenium","range":"(0,0005 – 10) mg/l"},{"name":"thallium","range":"(0,0005 – 10) mg/l"}],"search_en":"Element content Inductively coupled plasma mass spectrometry (ICP-MS) antimony arsenic barium chromium zinc cadmium copper molybdenum nickel lead mercury selenium thallium PN-EN ISO 17294-2:2024-04","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","methodology_zh":"元素含量","parameters_zh":[{"name":"锑","range":"(0,0005 – 10) mg/l"},{"name":"砷","range":"(0,0005 – 10) mg/l"},{"name":"钡","range":"(0,001 – 10) mg/l"},{"name":"铬","range":"(0,001 – 10) mg/l"},{"name":"锌","range":"(0,01 – 20) mg/l"},{"name":"镉","range":"(0,0005 – 10) mg/l"},{"name":"铜","range":"(0,001 – 10) mg/l"},{"name":"钼","range":"(0,0005 – 10) mg/l"},{"name":"镍","range":"(0,001 – 10) mg/l"},{"name":"铅","range":"(0,001 – 10) mg/l"},{"name":"汞","range":"(0,0002 – 1) mg/l"},{"name":"硒","range":"(0,0005 – 10) mg/l"},{"name":"铊","range":"(0,0005 – 10) mg/l"}],"search_zh":"元素含量 电感耦合等离子体质谱法（ICP-MS） 锑 砷 钡 铬 锌 镉 铜 钼 镍 铅 汞 硒 铊 PN-EN ISO 17294-2:2024-04","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a832b7f884ede9a1b2c56e0","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba, grunty, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Sucha masa","parameters":[{"name":"Zakres","range":"(0,10 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa\nZakres (0,10 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 | PN-EN 14346:2011","norm_bases":["PN-EN 15934:2013-02","PN-EN 14346:2011"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Sucha masa\nZakres (0,10 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 | PN-EN 14346:2011 Gleba, grunty, Odpady kod: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Sucha masa\nZakres (0,10 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 | PN-EN 14346:2011","categories":["environment"],"row_index":536,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter","parameters_en":[{"name":"Range","range":"(0,10 – 99,0) %"}],"search_en":"Dry matter Gravimetric method Range PN-EN 15934:2013-02 | PN-EN 14346:2011","technique_en":"Gravimetric method","methodology_zh":"干物质","parameters_zh":[{"name":"范围","range":"(0,10 – 99,0) %"}],"search_zh":"干物质 重量法 范围 PN-EN 15934:2013-02 | PN-EN 14346:2011","technique_zh":"重量法"},{"_id":"6a832b7f884ede9a1b2c56e1","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość pestycydów chloroorganicznych","parameters":[{"name":"Suma dichlorodifenylodichloroetanów (DDD) Suma dichlorodifenylodichloroetylenów (DDE) Suma dichlorodifenylotrichloroetanów (DDT) (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość pestycydów chloroorganicznych\nSuma dichlorodifenylodichloroetanów (DDD) Suma dichlorodifenylodichloroetylenów (DDE) Suma dichlorodifenylotrichloroetanów (DDT) (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość pestycydów chloroorganicznych\nSuma dichlorodifenylodichloroetanów (DDD) Suma dichlorodifenylodichloroetylenów (DDE) Suma dichlorodifenylotrichloroetanów (DDT) (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) Normy Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc pestycydow chloroorganicznych\nSuma dichlorodifenylodichloroetanow (DDD) Suma dichlorodifenylodichloroetylenow (DDE) Suma dichlorodifenylotrichloroetanow (DDT) (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) Normy","categories":["environment"],"row_index":537,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Organochlorine pesticide content","parameters_en":[{"name":"Sum of dichlorodiphenyldichloroethanes (DDD) Sum of dichlorodiphenyldichloroethylenes (DDE) Sum of dichlorodiphenyltrichloroethanes (DDT) (calculated)"}],"search_en":"Organochlorine pesticide content Gas chromatography with mass spectrometry detection (GC-MS) Sum of dichlorodiphenyldichloroethanes (DDD) Sum of dichlorodiphenyldichloroethylenes (DDE) Sum of dichlorodiphenyltrichloroethanes (DDT) (calculated) Normy","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","search_zh":"有机氯农药含量 气相色谱-质谱法（GC-MS） Normy","technique_zh":"气相色谱-质谱法（GC-MS）","methodology_zh":"有机氯农药含量"},{"_id":"6a832b7f884ede9a1b2c56e2","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) Normy Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc pierwiastkow\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) Normy","categories":["environment"],"row_index":538,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","search_en":"Element content Inductively coupled plasma mass spectrometry (ICP-MS) Normy","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","methodology_zh":"元素含量","search_zh":"元素含量 电感耦合等离子体质谱法（ICP-MS） Normy","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a832b7f884ede9a1b2c56e3","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość lotnych związków organicznych","parameters":[],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Zawartość lotnych związków organicznych\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość lotnych związków organicznych\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) Normy Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc lotnych zwiazkow organicznych\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) Normy","categories":["environment"],"row_index":539,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile organic compound content","search_en":"Volatile organic compound content Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) Normy","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","search_zh":"挥发性有机化合物含量 顶空气相色谱-质谱法（HS-GC-MS） Normy","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）","methodology_zh":"挥发性有机化合物含量"},{"_id":"6a832b7f884ede9a1b2c56e4","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Suma lotnych jednopierścieniowych węglowodorów aromatycznych (BTEX) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma lotnych jednopierścieniowych węglowodorów aromatycznych (BTEX) (z obliczeń)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Suma lotnych jednopierścieniowych węglowodorów aromatycznych (BTEX) (z obliczeń) Normy Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Suma lotnych jednopierscieniowych weglowodorow aromatycznych (BTEX) (z obliczen) Normy","categories":["environment"],"row_index":540,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of volatile monocyclic aromatic hydrocarbons (BTEX) (calculated)","search_en":"Sum of volatile monocyclic aromatic hydrocarbons (BTEX) (calculated) Normy"},{"_id":"6a832b7f884ede9a1b2c56e5","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Suma ksylenów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma ksylenów (z obliczeń)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Suma ksylenów (z obliczeń) Normy Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Suma ksylenow (z obliczen) Normy","categories":["environment"],"row_index":541,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of xylenes (calculated)","search_en":"Sum of xylenes (calculated) Normy"},{"_id":"6a832b7f884ede9a1b2c56e6","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Suma lotnych związków organicznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma lotnych związków organicznych (z obliczeń)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Suma lotnych związków organicznych (z obliczeń) Normy Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Suma lotnych zwiazkow organicznych (z obliczen) Normy","categories":["environment"],"row_index":542,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of volatile organic compounds (calculated)","search_en":"Sum of volatile organic compounds (calculated) Normy","methodology_zh":"挥发性有机化合物总量（由计算得出）","search_zh":"挥发性有机化合物总量（由计算得出） Normy"},{"_id":"6a832b7f884ede9a1b2c56e7","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Suma dichlorobenzenów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma dichlorobenzenów (z obliczeń)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Suma dichlorobenzenów (z obliczeń) Normy Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Suma dichlorobenzenow (z obliczen) Normy","categories":["environment"],"row_index":543,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of dichlorobenzenes (calculated)","search_en":"Sum of dichlorobenzenes (calculated) Normy"},{"_id":"6a832b7f884ede9a1b2c56e8","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Suma trichlorobenzenów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma trichlorobenzenów (z obliczeń)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Suma trichlorobenzenów (z obliczeń) Normy Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Suma trichlorobenzenow (z obliczen) Normy","categories":["environment"],"row_index":544,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of trichlorobenzenes (calculated)","search_en":"Sum of trichlorobenzenes (calculated) Normy","methodology_zh":"三氯苯总量（由计算得出）","search_zh":"三氯苯总量（由计算得出） Normy"},{"_id":"6a832b7f884ede9a1b2c56e9","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość węglowodorów C6-C12, frakcja benzy","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/kg"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Zawartość węglowodorów C6-C12, frakcja benzy\nZakres (1,0 – 1000) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"Norm","norm_bases":["Norm"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość węglowodorów C6-C12, frakcja benzy\nZakres (1,0 – 1000) mg/kg\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) Norm Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc weglowodorow C6-C12, frakcja benzy\nZakres (1,0 – 1000) mg/kg\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) Norm","categories":["environment"],"row_index":545,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of hydrocarbons C6-C12, petrol fraction","parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/kg"}],"search_en":"Content of hydrocarbons C6-C12, petrol fraction Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) Range Norm","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/kg"}],"search_zh":"顶空气相色谱-质谱法（HS-GC-MS） 范围 Norm","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）"},{"_id":"6a832b7f884ede9a1b2c56ea","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość węglowodorów C12-C35, C10-C40, C10-C22, frakcja oleju","parameters":[{"name":"Zakres","range":"(30 – 25000) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość węglowodorów C12-C35, C10-C40, C10-C22, frakcja oleju\nZakres (30 – 25000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Norm","norm_bases":["Norm"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość węglowodorów C12-C35, C10-C40, C10-C22, frakcja oleju\nZakres (30 – 25000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Norm Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc weglowodorow C12-C35, C10-C40, C10-C22, frakcja oleju\nZakres (30 – 25000) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Norm","categories":["environment","petro"],"row_index":546,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of hydrocarbons C12-C35, C10-C40, C10-C22, oil fraction","parameters_en":[{"name":"Range","range":"(30 – 25000) mg/kg"}],"search_en":"Content of hydrocarbons C12-C35, C10-C40, C10-C22, oil fraction Gas chromatography with flame ionization detection (GC-FID) Range Norm","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","parameters_zh":[{"name":"范围","range":"(30 – 25000) mg/kg"}],"search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） 范围 Norm","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a832b7f884ede9a1b2c56eb","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznyc","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznyc\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"Norm","norm_bases":["Norm"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość wielopierścieniowych węglowodorów aromatycznyc\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) Norm Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc wielopierscieniowych weglowodorow aromatycznyc\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) Norm","categories":["environment"],"row_index":547,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of polycyclic aromatic hydrocarbon","search_en":"Content of polycyclic aromatic hydrocarbon Gas chromatography with mass spectrometry detection (GC-MS) Norm","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","search_zh":"气相色谱-质谱法（GC-MS） Norm","technique_zh":"气相色谱-质谱法（GC-MS）"},{"_id":"6a832b7f884ede9a1b2c56ec","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń) Normy Gleba E, Grunty E; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Suma wielopierscieniowych weglowodorow aromatycznych (WWA) (z obliczen) Normy","categories":["environment"],"row_index":548,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of polycyclic aromatic hydrocarbons (PAH) (calculated)","search_en":"Sum of polycyclic aromatic hydrocarbons (PAH) (calculated) Normy","methodology_zh":"多环芳烃（PAH）总量（由计算得出）","search_zh":"多环芳烃（PAH）总量（由计算得出） Normy"},{"_id":"6a832b7f884ede9a1b2c56ed","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady kod E: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość lotnych związków organicznych","parameters":[],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Zawartość lotnych związków organicznych\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady kod E: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość lotnych związków organicznych\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) Normy Odpady kod E: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc lotnych zwiazkow organicznych\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) Normy","categories":["environment"],"row_index":549,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile organic compound content","search_en":"Volatile organic compound content Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) Normy","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","search_zh":"挥发性有机化合物含量 顶空气相色谱-质谱法（HS-GC-MS） Normy","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）","methodology_zh":"挥发性有机化合物含量"},{"_id":"6a832b7f884ede9a1b2c56ee","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady kod E: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Suma lotnych węglowodorów aromatycznych (BTEX) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma lotnych węglowodorów aromatycznych (BTEX) (z obliczeń)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady kod E: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Suma lotnych węglowodorów aromatycznych (BTEX) (z obliczeń) Normy Odpady kod E: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Suma lotnych weglowodorow aromatycznych (BTEX) (z obliczen) Normy","categories":["environment"],"row_index":550,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of volatile aromatic hydrocarbons (BTEX) (calculated)","search_en":"Sum of volatile aromatic hydrocarbons (BTEX) (calculated) Normy"},{"_id":"6a832b7f884ede9a1b2c56ef","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady kod E: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Suma lotnych związków organicznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma lotnych związków organicznych (z obliczeń)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady kod E: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Suma lotnych związków organicznych (z obliczeń) Normy Odpady kod E: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Suma lotnych zwiazkow organicznych (z obliczen) Normy","categories":["environment"],"row_index":551,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of volatile organic compounds (calculated)","search_en":"Sum of volatile organic compounds (calculated) Normy","methodology_zh":"挥发性有机化合物总量（由计算得出）","search_zh":"挥发性有机化合物总量（由计算得出） Normy"},{"_id":"6a832b7f884ede9a1b2c56f0","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady kod E: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady kod E: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) Normy Odpady kod E: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc pierwiastkow\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) Normy","categories":["environment"],"row_index":552,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","search_en":"Element content Inductively coupled plasma mass spectrometry (ICP-MS) Normy","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","methodology_zh":"元素含量","search_zh":"元素含量 电感耦合等离子体质谱法（ICP-MS） Normy","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a832b7f884ede9a1b2c56f1","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady kod E: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość węglowodorów C12-C35, C10-C40, C10-C22 / olej mineralny","parameters":[{"name":"Zakres","range":"(30 – 25000) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość węglowodorów C12-C35, C10-C40, C10-C22 / olej mineralny\nZakres (30 – 25000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady kod E: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość węglowodorów C12-C35, C10-C40, C10-C22 / olej mineralny\nZakres (30 – 25000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Normy Odpady kod E: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc weglowodorow C12-C35, C10-C40, C10-C22 / olej mineralny\nZakres (30 – 25000) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Normy","categories":["environment","petro"],"row_index":553,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of hydrocarbons C12-C35, C10-C40, C10-C22 / mineral oil","parameters_en":[{"name":"Range","range":"(30 – 25000) mg/kg"}],"search_en":"Content of hydrocarbons C12-C35, C10-C40, C10-C22 / mineral oil Gas chromatography with flame ionization detection (GC-FID) Range Normy","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","parameters_zh":[{"name":"范围","range":"(30 – 25000) mg/kg"}],"search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） 范围 Normy","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a832b7f884ede9a1b2c56f2","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Odpady kod E: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady kod E: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Zawartość wielopierścieniowych węglowodorów aromatycznych\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) Normy Odpady kod E: 17 01 01, 17 01 02, 17 01 03, 17 01 07, 17 03 02, 17 05 04, 17 05 06, 17 05 08; O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Zawartosc wielopierscieniowych weglowodorow aromatycznych\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) Normy","categories":["environment"],"row_index":554,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of polycyclic aromatic hydrocarbons","search_en":"Content of polycyclic aromatic hydrocarbons Gas chromatography with mass spectrometry detection (GC-MS) Normy","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","search_zh":"多环芳烃含量 气相色谱-质谱法（GC-MS） Normy","technique_zh":"气相色谱-质谱法（GC-MS）","methodology_zh":"多环芳烃含量"},{"_id":"6a832b7f884ede9a1b2c56f3","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Stężenie lotnych węglowodorów aromatycznych","parameters":[],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Stężenie lotnych węglowodorów aromatycznych\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Stężenie lotnych węglowodorów aromatycznych\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) Normy Woda E, Woda do spozycia przez ludzi E; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Stezenie lotnych weglowodorow aromatycznych\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) Normy","categories":["water"],"row_index":555,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of volatile aromatic hydrocarbons","search_en":"Concentration of volatile aromatic hydrocarbons Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) Normy","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","search_zh":"挥发性芳香烃浓度 顶空气相色谱-质谱法（HS-GC-MS） Normy","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）","methodology_zh":"挥发性芳香烃浓度"},{"_id":"6a832b7f884ede9a1b2c56f4","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Suma lotnych węglowodorów aromatycznych (BTEX) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma lotnych węglowodorów aromatycznych (BTEX) (z obliczeń)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Suma lotnych węglowodorów aromatycznych (BTEX) (z obliczeń) Normy Woda E, Woda do spozycia przez ludzi E; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Suma lotnych weglowodorow aromatycznych (BTEX) (z obliczen) Normy","categories":["water"],"row_index":556,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of volatile aromatic hydrocarbons (BTEX) (calculated)","search_en":"Sum of volatile aromatic hydrocarbons (BTEX) (calculated) Normy"},{"_id":"6a832b7f884ede9a1b2c56f5","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Stężenie łatwo lotnych chlorowcowych pochodnych węglowodorów","parameters":[],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Stężenie łatwo lotnych chlorowcowych pochodnych węglowodorów\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Stężenie łatwo lotnych chlorowcowych pochodnych węglowodorów\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) Normy Woda E, Woda do spozycia przez ludzi E; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Stezenie latwo lotnych chlorowcowych pochodnych weglowodorow\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) Normy","categories":["water"],"row_index":557,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of highly volatile halogenated hydrocarbons","search_en":"Concentration of highly volatile halogenated hydrocarbons Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) Normy","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","search_zh":"易挥发卤代烃浓度 顶空气相色谱-质谱法（HS-GC-MS） Normy","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）","methodology_zh":"易挥发卤代烃浓度"},{"_id":"6a832b7f884ede9a1b2c56f6","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Suma trihalogenometanów (THM) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma trihalogenometanów (THM) (z obliczeń)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Suma trihalogenometanów (THM) (z obliczeń) Normy Woda E, Woda do spozycia przez ludzi E; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Suma trihalogenometanow (THM) (z obliczen) Normy","categories":["water"],"row_index":558,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of trihalomethanes (THM) (calculated)","search_en":"Sum of trihalomethanes (THM) (calculated) Normy"},{"_id":"6a832b7f884ede9a1b2c56f7","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Suma trichloroetenu i tetrachloroetenu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma trichloroetenu i tetrachloroetenu (z obliczeń)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E; E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Suma trichloroetenu i tetrachloroetenu (z obliczeń) Normy Woda E, Woda do spozycia przez ludzi E; E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Suma trichloroetenu i tetrachloroetenu (z obliczen) Normy","categories":["water"],"row_index":559,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of trichloroethene and tetrachloroethene (calculated)","search_en":"Sum of trichloroethene and tetrachloroethene (calculated) Normy","methodology_zh":"三氯乙烯与四氯乙烯总量（由计算得出）","search_zh":"三氯乙烯与四氯乙烯总量（由计算得出） Normy"},{"_id":"6a832b7f884ede9a1b2c56f8","lab_id":"69ad52a3de79e566650fb171","country":"PL","accr_number":"AB 213","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie węglowodorów C6-C12, frakcja benzyn","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/l"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"computed":[],"activity":"Stężenie węglowodorów C6-C12, frakcja benzyn\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Laboratorium; Oddział Katowice","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie węglowodorów C6-C12, frakcja benzyn\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) Normy Woda Stezenie weglowodorow C6-C12, frakcja benzyn\nZakres (0,10 – 100) mg/l\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) Normy","categories":["water"],"row_index":560,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of C6-C12 hydrocarbons, gasoline fraction","parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/l"}],"search_en":"Water Concentration of C6-C12 hydrocarbons, gasoline fraction Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) Range Normy","technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/l"}],"search_zh":"水 顶空气相色谱-质谱法（HS-GC-MS） 范围 Normy","test_object_zh":"水","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）"}],"has_pdf":true}