{"lab":{"_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","address":"OCHRONY PRZECIWPOŻAROWEJ im. Józefa Tuliszkowskiego, - PAŃSTWOWY INSTYTUT BADAWCZY, ZESPÓŁ LABORATORIÓW SYGNALIZACJI ALARMU POŻARU, I AUTOMATYKI POŻARNICZEJ BA, ul. Nadwiślańska 213","categories":["electronics"],"city":"Józefów k","imported_at":"2026-03-08T10:42:43.265Z","methods_count":63,"name":"CENTRUM NAUKOWO-BADAWCZE","parse_status":"parsed","parse_version":3,"pdf_files":["AB_207.pdf"],"scope_summary":"","search_text":"centrum naukowo-badawcze ochrony przeciwpożarowej im. józefa tuliszkowskiego, - państwowy instytut badawczy, zespół laboratoriów sygnalizacji alarmu pożaru, i automatyki pożarniczej ba, ul. nadwiślańska 213 other electronics pharma materials environment water metrology automotive construction","status":"active","updated_at":"2026-03-08T14:51:05.466Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T20:06:06.401Z","email_confidence":"high","email_mx":true,"email_source":"https://www.cnbop.pl/pl/kontakt","fields_of_testing":[{"codes":"A/5; A/6; A/13; A/37; A/53; A/54","pl":"Badania akustyczne i drgań wyrobów, materiałów i obiektów budowlanych, wyrobów i wyposażenia elektrycznego, maszyn i urządzeń, zakładów produkcyjnych, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego","en":"Acoustic and vibration tests of building products, materials and items, electrical products and equipment, machinery and devices, production plants, telecommunication products and equipment, electronic products and equipment","table_header_pl":"Przedmiot badań/wyrób | Rodzaj działalności/badane cechy/metoda | Dokumenty odniesienia","table_header_en":"Material/product tested | Type of activity/parameter/characteristic tested | Reference documents"},{"codes":"E/5; E/6; E/13; E/37; E/53; E/54","pl":"Badania elektryczne wyrobów, materiałów i obiektów budowlanych, wyrobów i wyposażenia elektrycznego, maszyn i urządzeń, zakładów produkcyjnych, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego","en":"Electric and electronic tests of building products, materials and items, electrical products and equipment, machinery and devices, production plants, telecommunication products and equipment, electronic products and equipment"},{"codes":"F/5; F/6; F/13; F/37; F/53; F/54","pl":"Badania kompatybilności elektromagnetycznej wyrobów, materiałów i obiektów budowlanych, wyrobów i wyposażenia elektrycznego, maszyn i urządzeń, zakładów produkcyjnych, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego","en":"Electromagnetic Compatibility (EMC) tests of building products, materials and items, electrical products and equipment, machinery and devices, production plants, telecommunication products and equipment, electronic products and equipment"},{"codes":"G/5; G/6; G/13; G/37; G/53; G/54","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) wyrobów, materiałów i obiektów budowlanych, wyrobów i wyposażenia elektrycznego, maszyn i urządzeń, zakładów produkcyjnych, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego","en":"Tests concerning environmental engineering (envirnomental and climatic) tests of building products, materials and items, electrical products and equipment, machinery and devices, production plants, telecommunication products and equipment, electronic products and equipment"},{"codes":"J/6; J13","pl":"Badania mechaniczne wyrobów i wyposażenia elektrycznego, maszyn i urzadzeń","en":"Mechanical tests of electrical products and equipment, machinery and devices"},{"codes":"N/5; N/6; N/13; N/37; N/53; N/54","pl":"Badania właściwości fizycznych wyrobów, materiałów i obiektów budowlanych, wyrobów i wyposażenia elektrycznego, maszyn i urządzeń, zakładów produkcyjnych, wyrobów i wyposażenia telekomunikacyjnego, wyrobów i wyposażenia elektronicznego","en":"Tests of physical properties of building products, materials and items, electrical products and equipment, machinery and devices, production plants, telecommunication products and equipment, electronic products and equipment"}],"issue":{"no":"28","date":"08.07.2026"},"parse_date":"2026-08-17T20:06:06.401Z","parse_source":"agent-claude-code","scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/83e625046f39901a6181eb34588b6793/AB%20207.pdf","has_en":true,"category_counts":{"other":45,"electronics":17,"water":1,"environment":1,"materials":1,"construction":1},"category_scores":{"other":30.68,"electronics":4.38,"water":0.02,"environment":0.02,"materials":0.02,"construction":0.02},"has_zh":true},"methods":[{"_id":"6a8369aeaf14b9c0e7b1dbb6","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems","methodology":"Próba A - zimno – odporność / Test A – cold - operational","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Próba A - zimno – odporność / Test A – cold - operational","reference":"PN-EN 60068-2-1:2009 (EN 60068-2-1:2007 IEC 60068-2-1:2007) | PN-EN 60945:2004 (EN 60945:2002 IEC 60945:2002) p. 8.4","norm_bases":["PN-EN 60068-2-1:2009 (EN 60068-2-1:2007 IEC 60068-2-1:2007)","PN-EN 60945:2004 (EN 60945:2002 IEC 60945:2002) p. 8.4"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Próba A - zimno – odporność / Test A – cold - operational PN-EN 60068-2-1:2009 (EN 60068-2-1:2007 IEC 60068-2-1:2007) | PN-EN 60945:2004 (EN 60945:2002 IEC 60945:2002) p. 8.4 Systemy sygnalizacji pozarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepla / Electrical smoke and heat control systems, Dzwiekowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujace / Integrating fire devices systems, Systemy transmisji alarmow / Alarm transmission and fault warning routing equipment, Systemy kontroli dostepu / Access control systems, Systemy wlamaniowe / Alarm and electronic security systems, Systemy oswietlenia awaryjnego / Emergency lighting systems, Urzadzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Proba A - zimno – odpornosc / Test A – cold - operational PN-EN 60068-2-1:2009 (EN 60068-2-1:2007 IEC 60068-2-1:2007) | PN-EN 60945:2004 (EN 60945:2002 IEC 60945:2002) p. 8.4","categories":["electronics"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbb7","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems","methodology":"Próba B - suche gorąco – odporność / Test B: Dry heat - operational, Próba B - suche gorąco – wytrzymałość, Test B: Dry heat - endurance","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Próba B - suche gorąco – odporność / Test B: Dry heat - operational, Próba B - suche gorąco – wytrzymałość, Test B: Dry heat - endurance","reference":"PN-EN 60068-2-2:2009 (EN 60068-2-2:2007 IEC 60068-2-2:2007) | PN-EN 60945:2004 (EN 60945:2002 IEC 60945:2002) p. 8.2","norm_bases":["PN-EN 60068-2-2:2009 (EN 60068-2-2:2007 IEC 60068-2-2:2007)","PN-EN 60945:2004 (EN 60945:2002 IEC 60945:2002) p. 8.2"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Próba B - suche gorąco – odporność / Test B: Dry heat - operational, Próba B - suche gorąco – wytrzymałość, Test B: Dry heat - endurance PN-EN 60068-2-2:2009 (EN 60068-2-2:2007 IEC 60068-2-2:2007) | PN-EN 60945:2004 (EN 60945:2002 IEC 60945:2002) p. 8.2 Systemy sygnalizacji pozarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepla / Electrical smoke and heat control systems, Dzwiekowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujace / Integrating fire devices systems, Systemy transmisji alarmow / Alarm transmission and fault warning routing equipment, Systemy kontroli dostepu / Access control systems, Systemy wlamaniowe / Alarm and electronic security systems, Systemy oswietlenia awaryjnego / Emergency lighting systems, Urzadzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Proba B - suche goraco – odpornosc / Test B: Dry heat - operational, Proba B - suche goraco – wytrzymalosc, Test B: Dry heat - endurance PN-EN 60068-2-2:2009 (EN 60068-2-2:2007 IEC 60068-2-2:2007) | PN-EN 60945:2004 (EN 60945:2002 IEC 60945:2002) p. 8.2","categories":["electronics"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbb8","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems","methodology":"Próba Fc - wibracje sinusoidalne / Test Fc - vibration (sinusoidal)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Próba Fc - wibracje sinusoidalne / Test Fc - vibration (sinusoidal)","reference":"PN-EN 60068-2-6:2008 (EN 60068-2-6:2008 IEC 60068-2-6:2007) | PN-EN 60068-2-6:2002 (EN 60068-2-6:1995 IEC 60068-2-6:1995+COR1:1995) | PN-EN 60945:2004 (EN 60945:2002 IEC 60945:2002) p. 8.7","norm_bases":["PN-EN 60068-2-6:2008 (EN 60068-2-6:2008 IEC 60068-2-6:2007)","PN-EN 60068-2-6:2002 (EN 60068-2-6:1995 IEC 60068-2-6:1995+COR1:1995)","PN-EN 60945:2004 (EN 60945:2002 IEC 60945:2002) p. 8.7"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Próba Fc - wibracje sinusoidalne / Test Fc - vibration (sinusoidal) PN-EN 60068-2-6:2008 (EN 60068-2-6:2008 IEC 60068-2-6:2007) | PN-EN 60068-2-6:2002 (EN 60068-2-6:1995 IEC 60068-2-6:1995+COR1:1995) | PN-EN 60945:2004 (EN 60945:2002 IEC 60945:2002) p. 8.7 Systemy sygnalizacji pozarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepla / Electrical smoke and heat control systems, Dzwiekowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujace / Integrating fire devices systems, Systemy transmisji alarmow / Alarm transmission and fault warning routing equipment, Systemy kontroli dostepu / Access control systems, Systemy wlamaniowe / Alarm and electronic security systems, Systemy oswietlenia awaryjnego / Emergency lighting systems, Urzadzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Proba Fc - wibracje sinusoidalne / Test Fc - vibration (sinusoidal) PN-EN 60068-2-6:2008 (EN 60068-2-6:2008 IEC 60068-2-6:2007) | PN-EN 60068-2-6:2002 (EN 60068-2-6:1995 IEC 60068-2-6:1995+COR1:1995) | PN-EN 60945:2004 (EN 60945:2002 IEC 60945:2002) p. 8.7","categories":["electronics"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbb9","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems","methodology":"Próba Ea – udary / Test Ea – shock","parameters":[{"name":"Zakres/range","range":"do/to 100g"}],"technique":null,"techniques":[],"computed":[],"activity":"Próba Ea – udary / Test Ea – shock\nZakres/range do/to 100g","reference":"PN-EN 60068-2-27:2009 (EN 60068-2-27:2009 IEC 60068-2-27:2008)","norm_bases":["PN-EN 60068-2-27:2009 (EN 60068-2-27:2009 IEC 60068-2-27:2008)"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Próba Ea – udary / Test Ea – shock\nZakres/range do/to 100g PN-EN 60068-2-27:2009 (EN 60068-2-27:2009 IEC 60068-2-27:2008) Systemy sygnalizacji pozarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepla / Electrical smoke and heat control systems, Dzwiekowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujace / Integrating fire devices systems, Systemy transmisji alarmow / Alarm transmission and fault warning routing equipment, Systemy kontroli dostepu / Access control systems, Systemy wlamaniowe / Alarm and electronic security systems, Systemy oswietlenia awaryjnego / Emergency lighting systems, Urzadzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Proba Ea – udary / Test Ea – shock\nZakres/range do/to 100g PN-EN 60068-2-27:2009 (EN 60068-2-27:2009 IEC 60068-2-27:2008)","categories":["electronics"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbba","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems","methodology":"Próba Db - wilgotne gorąco cykliczne – odporność / Test Db: damp heat, cyclic (12 h + 12 h cycle) - operational, Próba Db - wilgotne gorąco cykliczne – wytrzymałość / Test Db: damp heat, cyclic (12 h + 12 h cycle) - endurance","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Próba Db - wilgotne gorąco cykliczne – odporność / Test Db: damp heat, cyclic (12 h + 12 h cycle) - operational, Próba Db - wilgotne gorąco cykliczne – wytrzymałość / Test Db: damp heat, cyclic (12 h + 12 h cycle) - endurance","reference":"PN-EN 60068-2-30:2008 (EN 60068-2-30:2005 IEC 60068-2-30:2005) | PN-EN 60945:2004 (EN 60945:2002 IEC 60945:2002) p. 8.3","norm_bases":["PN-EN 60068-2-30:2008 (EN 60068-2-30:2005 IEC 60068-2-30:2005)","PN-EN 60945:2004 (EN 60945:2002 IEC 60945:2002) p. 8.3"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Próba Db - wilgotne gorąco cykliczne – odporność / Test Db: damp heat, cyclic (12 h + 12 h cycle) - operational, Próba Db - wilgotne gorąco cykliczne – wytrzymałość / Test Db: damp heat, cyclic (12 h + 12 h cycle) - endurance PN-EN 60068-2-30:2008 (EN 60068-2-30:2005 IEC 60068-2-30:2005) | PN-EN 60945:2004 (EN 60945:2002 IEC 60945:2002) p. 8.3 Systemy sygnalizacji pozarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepla / Electrical smoke and heat control systems, Dzwiekowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujace / Integrating fire devices systems, Systemy transmisji alarmow / Alarm transmission and fault warning routing equipment, Systemy kontroli dostepu / Access control systems, Systemy wlamaniowe / Alarm and electronic security systems, Systemy oswietlenia awaryjnego / Emergency lighting systems, Urzadzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Proba Db - wilgotne goraco cykliczne – odpornosc / Test Db: damp heat, cyclic (12 h + 12 h cycle) - operational, Proba Db - wilgotne goraco cykliczne – wytrzymalosc / Test Db: damp heat, cyclic (12 h + 12 h cycle) - endurance PN-EN 60068-2-30:2008 (EN 60068-2-30:2005 IEC 60068-2-30:2005) | PN-EN 60945:2004 (EN 60945:2002 IEC 60945:2002) p. 8.3","categories":["electronics"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbbb","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems","methodology":"Próba Kc - oddziaływanie SO2 na styki i połączenia, Test Kc: sulphur dioxide test for contacts and connections","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Próba Kc - oddziaływanie SO2 na styki i połączenia, Test Kc: sulphur dioxide test for contacts and connections","reference":"PN-EN 60068-2-42:2004 (EN 60068-2-42:2003 IEC 60068-2-42:2003)","norm_bases":["PN-EN 60068-2-42:2004 (EN 60068-2-42:2003 IEC 60068-2-42:2003)"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Próba Kc - oddziaływanie SO2 na styki i połączenia, Test Kc: sulphur dioxide test for contacts and connections PN-EN 60068-2-42:2004 (EN 60068-2-42:2003 IEC 60068-2-42:2003) Systemy sygnalizacji pozarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepla / Electrical smoke and heat control systems, Dzwiekowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujace / Integrating fire devices systems, Systemy transmisji alarmow / Alarm transmission and fault warning routing equipment, Systemy kontroli dostepu / Access control systems, Systemy wlamaniowe / Alarm and electronic security systems, Systemy oswietlenia awaryjnego / Emergency lighting systems, Urzadzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Proba Kc - oddzialywanie SO2 na styki i polaczenia, Test Kc: sulphur dioxide test for contacts and connections PN-EN 60068-2-42:2004 (EN 60068-2-42:2003 IEC 60068-2-42:2003)","categories":["electronics"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbbc","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems","methodology":"Próba Ehb - uderzenie / Test Ehb: hammer tests","parameters":[{"name":"Zakres /range","range":"0,5 ± 0,1 J"}],"technique":null,"techniques":[],"computed":[],"activity":"Próba Ehb - uderzenie / Test Ehb: hammer tests\nZakres /range 0,5 ± 0,1 J","reference":"PN-EN 60068-2-75:2000 (EN 60068-2-75:1997 IEC 60068-2-75:1997) | PN-EN 60068-2-75:2015 (EN 60068-2-75:2014 IEC 60068-2-75:2014)","norm_bases":["PN-EN 60068-2-75:2000 (EN 60068-2-75:1997 IEC 60068-2-75:1997)","PN-EN 60068-2-75:2015 (EN 60068-2-75:2014 IEC 60068-2-75:2014)"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Próba Ehb - uderzenie / Test Ehb: hammer tests\nZakres /range 0,5 ± 0,1 J PN-EN 60068-2-75:2000 (EN 60068-2-75:1997 IEC 60068-2-75:1997) | PN-EN 60068-2-75:2015 (EN 60068-2-75:2014 IEC 60068-2-75:2014) Systemy sygnalizacji pozarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepla / Electrical smoke and heat control systems, Dzwiekowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujace / Integrating fire devices systems, Systemy transmisji alarmow / Alarm transmission and fault warning routing equipment, Systemy kontroli dostepu / Access control systems, Systemy wlamaniowe / Alarm and electronic security systems, Systemy oswietlenia awaryjnego / Emergency lighting systems, Urzadzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Proba Ehb - uderzenie / Test Ehb: hammer tests\nZakres /range 0,5 ± 0,1 J PN-EN 60068-2-75:2000 (EN 60068-2-75:1997 IEC 60068-2-75:1997) | PN-EN 60068-2-75:2015 (EN 60068-2-75:2014 IEC 60068-2-75:2014)","categories":["electronics"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"range","range":"0,5 ± 0,1 J"}],"search_en":"range PN-EN 60068-2-75:2000 (EN 60068-2-75:1997 IEC 60068-2-75:1997) | PN-EN 60068-2-75:2015 (EN 60068-2-75:2014 IEC 60068-2-75:2014)"},{"_id":"6a8369aeaf14b9c0e7b1dbbd","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems","methodology":"Próba Ca - wilgotne gorąco stałe – odporność / Test Ca: Damp heat, steady state – operational, Próba Ca - wilgotne gorąco stałe – wytrzymałość / Test Ca: Damp heat, steady state – endurance","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Próba Ca - wilgotne gorąco stałe – odporność / Test Ca: Damp heat, steady state – operational, Próba Ca - wilgotne gorąco stałe – wytrzymałość / Test Ca: Damp heat, steady state – endurance","reference":"PN-EN 60068-2-78:2013 (EN 60068-2-78:2013 IEC 60068-2-78:2012) | PN-EN 60068-2-78:2007 (EN 60068-2-78:2001 IEC 60068-2-78:2001)","norm_bases":["PN-EN 60068-2-78:2013 (EN 60068-2-78:2013 IEC 60068-2-78:2012)","PN-EN 60068-2-78:2007 (EN 60068-2-78:2001 IEC 60068-2-78:2001)"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Próba Ca - wilgotne gorąco stałe – odporność / Test Ca: Damp heat, steady state – operational, Próba Ca - wilgotne gorąco stałe – wytrzymałość / Test Ca: Damp heat, steady state – endurance PN-EN 60068-2-78:2013 (EN 60068-2-78:2013 IEC 60068-2-78:2012) | PN-EN 60068-2-78:2007 (EN 60068-2-78:2001 IEC 60068-2-78:2001) Systemy sygnalizacji pozarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepla / Electrical smoke and heat control systems, Dzwiekowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujace / Integrating fire devices systems, Systemy transmisji alarmow / Alarm transmission and fault warning routing equipment, Systemy kontroli dostepu / Access control systems, Systemy wlamaniowe / Alarm and electronic security systems, Systemy oswietlenia awaryjnego / Emergency lighting systems, Urzadzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Proba Ca - wilgotne goraco stale – odpornosc / Test Ca: Damp heat, steady state – operational, Proba Ca - wilgotne goraco stale – wytrzymalosc / Test Ca: Damp heat, steady state – endurance PN-EN 60068-2-78:2013 (EN 60068-2-78:2013 IEC 60068-2-78:2012) | PN-EN 60068-2-78:2007 (EN 60068-2-78:2001 IEC 60068-2-78:2001)","categories":["electronics"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbbe","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems","methodology":"Stopień ochrony obudowy IP / Degrees of protection provided by enclosures (IP code)","parameters":[{"name":"Zakres/range","range":"ochrony przed dostępem do części niebezpiecznych i ochrony przed obcymi ciałami stałymi - stopnie od 1 do 6 / protection that the enclosure provides against access to hazardous parts and the ingress of solid foreign objects – level from 1 to 6 ochrony przed wnikaniem wody - stopnie od 1 do 6 / protection that the enclosure provides against harmful ingress of water - level from 1 to 6"}],"technique":null,"techniques":[],"computed":[],"activity":"Stopień ochrony obudowy IP / Degrees of protection provided by enclosures (IP code)\nZakres/range ochrony przed dostępem do części niebezpiecznych i ochrony przed obcymi ciałami stałymi - stopnie od 1 do 6 / protection that the enclosure provides against access to hazardous parts and the ingress of solid foreign objects – level from 1 to 6 ochrony przed wnikaniem wody - stopnie od 1 do 6 / protection that the enclosure provides against harmful ingress of water - level from 1 to 6","reference":"PN-EN 60529:2003+AC:2017-12+AC:2020-01 (EN 60529:1991+A1:2000+A2:2013+AC:2016- 12+AC:2019-02 IEC 60529:1989+AMD1:1999 +AMD2:2013/COR2:2015+A2:2013+AC1:2019) | PN-EN 60945:2004 (EN 60945:2002 IEC 60945:2002) p. 8.8","norm_bases":["PN-EN 60529:2003+AC:2017-12+AC:2020-01 (EN 60529:1991+A1:2000+A2:2013+AC:2016- 12+AC:2019-02 IEC 60529:1989+AMD1:1999 +AMD2:2013/COR2:2015+A2:2013+AC1:2019)","PN-EN 60945:2004 (EN 60945:2002 IEC 60945:2002) p. 8.8"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Stopień ochrony obudowy IP / Degrees of protection provided by enclosures (IP code)\nZakres/range ochrony przed dostępem do części niebezpiecznych i ochrony przed obcymi ciałami stałymi - stopnie od 1 do 6 / protection that the enclosure provides against access to hazardous parts and the ingress of solid foreign objects – level from 1 to 6 ochrony przed wnikaniem wody - stopnie od 1 do 6 / protection that the enclosure provides against harmful ingress of water - level from 1 to 6 PN-EN 60529:2003+AC:2017-12+AC:2020-01 (EN 60529:1991+A1:2000+A2:2013+AC:2016- 12+AC:2019-02 IEC 60529:1989+AMD1:1999 +AMD2:2013/COR2:2015+A2:2013+AC1:2019) | PN-EN 60945:2004 (EN 60945:2002 IEC 60945:2002) p. 8.8 Systemy sygnalizacji pozarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepla / Electrical smoke and heat control systems, Dzwiekowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujace / Integrating fire devices systems, Systemy transmisji alarmow / Alarm transmission and fault warning routing equipment, Systemy kontroli dostepu / Access control systems, Systemy wlamaniowe / Alarm and electronic security systems, Systemy oswietlenia awaryjnego / Emergency lighting systems, Urzadzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Stopien ochrony obudowy IP / Degrees of protection provided by enclosures (IP code)\nZakres/range ochrony przed dostepem do czesci niebezpiecznych i ochrony przed obcymi cialami stalymi - stopnie od 1 do 6 / protection that the enclosure provides against access to hazardous parts and the ingress of solid foreign objects – level from 1 to 6 ochrony przed wnikaniem wody - stopnie od 1 do 6 / protection that the enclosure provides against harmful ingress of water - level from 1 to 6 PN-EN 60529:2003+AC:2017-12+AC:2020-01 (EN 60529:1991+A1:2000+A2:2013+AC:2016- 12+AC:2019-02 IEC 60529:1989+AMD1:1999 +AMD2:2013/COR2:2015+A2:2013+AC1:2019) | PN-EN 60945:2004 (EN 60945:2002 IEC 60945:2002) p. 8.8","categories":["water","electronics"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbbf","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems","methodology":"Próba z dwutlenkiem siarki z ogólną kondensacją wilgoci / Sulfur dioxide test with general condensation of moisture","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Próba z dwutlenkiem siarki z ogólną kondensacją wilgoci / Sulfur dioxide test with general condensation of moisture","reference":"PN-EN ISO 6988:2000 (EN ISO 6988:1994 ISO 6988:1985) | PN-EN ISO 22479:2022-12","norm_bases":["PN-EN ISO 6988:2000 (EN ISO 6988:1994 ISO 6988:1985)","PN-EN ISO 22479:2022-12"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Próba z dwutlenkiem siarki z ogólną kondensacją wilgoci / Sulfur dioxide test with general condensation of moisture PN-EN ISO 6988:2000 (EN ISO 6988:1994 ISO 6988:1985) | PN-EN ISO 22479:2022-12 Systemy sygnalizacji pozarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepla / Electrical smoke and heat control systems, Dzwiekowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujace / Integrating fire devices systems, Systemy transmisji alarmow / Alarm transmission and fault warning routing equipment, Systemy kontroli dostepu / Access control systems, Systemy wlamaniowe / Alarm and electronic security systems, Systemy oswietlenia awaryjnego / Emergency lighting systems, Urzadzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Proba z dwutlenkiem siarki z ogolna kondensacja wilgoci / Sulfur dioxide test with general condensation of moisture PN-EN ISO 6988:2000 (EN ISO 6988:1994 ISO 6988:1985) | PN-EN ISO 22479:2022-12","categories":["electronics"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbc0","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems","methodology":"Odporność na wyładowania elektrostatyczne / Electrostatic discharge immunity test","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na wyładowania elektrostatyczne / Electrostatic discharge immunity test","reference":"PN-EN 61000-4-2:2011 (EN 61000-4-2:2009 IEC 61000-4-2:2008) | PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003) | PN-EN 50130-4:2012+A1:2015-03 p. 9 (EN 50130-4:2011+A1:2014 p. 9) | IEC 62599-2:2010-05","norm_bases":["PN-EN 61000-4-2:2011 (EN 61000-4-2:2009 IEC 61000-4-2:2008)","PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003)","PN-EN 50130-4:2012+A1:2015-03 p. 9 (EN 50130-4:2011+A1:2014 p. 9)","IEC 62599-2:2010-05"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Odporność na wyładowania elektrostatyczne / Electrostatic discharge immunity test PN-EN 61000-4-2:2011 (EN 61000-4-2:2009 IEC 61000-4-2:2008) | PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003) | PN-EN 50130-4:2012+A1:2015-03 p. 9 (EN 50130-4:2011+A1:2014 p. 9) | IEC 62599-2:2010-05 Systemy sygnalizacji pozarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepla / Electrical smoke and heat control systems, Dzwiekowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujace / Integrating fire devices systems, Systemy transmisji alarmow / Alarm transmission and fault warning routing equipment, Systemy kontroli dostepu / Access control systems, Systemy wlamaniowe / Alarm and electronic security systems, Systemy oswietlenia awaryjnego / Emergency lighting systems, Urzadzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Odpornosc na wyladowania elektrostatyczne / Electrostatic discharge immunity test PN-EN 61000-4-2:2011 (EN 61000-4-2:2009 IEC 61000-4-2:2008) | PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003) | PN-EN 50130-4:2012+A1:2015-03 p. 9 (EN 50130-4:2011+A1:2014 p. 9) | IEC 62599-2:2010-05","categories":["electronics"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbc1","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems","methodology":"Odporność na pole elektromagnetyczne o częstotliwości radiowej w zakresie częstotliwości od 10 MHz do 2 GHz przy natężeniu pola do 30 V/m oraz w zakresie częstotliwości od 10 MHz do 4,2 GHz przy natężeniu pola do 10 V/m / Radiated, radio-frequency, electromagnetic field immunity test (frequency from 10 MHz to 2 GHz for 30 V/m field strength, frequency from 10 MHz to 4,2 GHz for 10 V/m field strength), Badania w komorze GTEM dla urządzeń o maksymalnych wymiarach (szer. x gł. x wys.) / Tests in the GTEM cell for devices with maximum dimensions (width x depth x height) 30 cm x 15 cm x 30 cm","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na pole elektromagnetyczne o częstotliwości radiowej w zakresie częstotliwości od 10 MHz do 2 GHz przy natężeniu pola do 30 V/m oraz w zakresie częstotliwości od 10 MHz do 4,2 GHz przy natężeniu pola do 10 V/m / Radiated, radio-frequency, electromagnetic field immunity test (frequency from 10 MHz to 2 GHz for 30 V/m field strength, frequency from 10 MHz to 4,2 GHz for 10 V/m field strength), Badania w komorze GTEM dla urządzeń o maksymalnych wymiarach (szer. x gł. x wys.) / Tests in the GTEM cell for devices with maximum dimensions (width x depth x height) 30 cm x 15 cm x 30 cm","reference":"PN-EN 61000-4-3:2007+A1:2008 +A2:2011+IS1:2009 (EN 61000-4-3:2006+A1:2008 +A2:2010+IS1:2009 IEC 61000-4-3:2006+AMD1:2007 +AMD2:2010+IS1:2009) | PN-EN IEC 61000-4-3:2021-06 (EN IEC 61000-4-3:2020 IEC 61000-4-3:2020) | PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003) | PN-EN 50130-4:2012+A1:2015-03 p. 10 (EN 50130-4:2011+A1:2014 p. 10) | IEC 62599-2:2010-05","norm_bases":["PN-EN 61000-4-3:2007+A1:2008 +A2:2011+IS1:2009 (EN 61000-4-3:2006+A1:2008 +A2:2010+IS1:2009 IEC 61000-4-3:2006+AMD1:2007 +AMD2:2010+IS1:2009)","PN-EN IEC 61000-4-3:2021-06 (EN IEC 61000-4-3:2020 IEC 61000-4-3:2020)","PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003)","PN-EN 50130-4:2012+A1:2015-03 p. 10 (EN 50130-4:2011+A1:2014 p. 10)","IEC 62599-2:2010-05"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Odporność na pole elektromagnetyczne o częstotliwości radiowej w zakresie częstotliwości od 10 MHz do 2 GHz przy natężeniu pola do 30 V/m oraz w zakresie częstotliwości od 10 MHz do 4,2 GHz przy natężeniu pola do 10 V/m / Radiated, radio-frequency, electromagnetic field immunity test (frequency from 10 MHz to 2 GHz for 30 V/m field strength, frequency from 10 MHz to 4,2 GHz for 10 V/m field strength), Badania w komorze GTEM dla urządzeń o maksymalnych wymiarach (szer. x gł. x wys.) / Tests in the GTEM cell for devices with maximum dimensions (width x depth x height) 30 cm x 15 cm x 30 cm PN-EN 61000-4-3:2007+A1:2008 +A2:2011+IS1:2009 (EN 61000-4-3:2006+A1:2008 +A2:2010+IS1:2009 IEC 61000-4-3:2006+AMD1:2007 +AMD2:2010+IS1:2009) | PN-EN IEC 61000-4-3:2021-06 (EN IEC 61000-4-3:2020 IEC 61000-4-3:2020) | PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003) | PN-EN 50130-4:2012+A1:2015-03 p. 10 (EN 50130-4:2011+A1:2014 p. 10) | IEC 62599-2:2010-05 Systemy sygnalizacji pozarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepla / Electrical smoke and heat control systems, Dzwiekowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujace / Integrating fire devices systems, Systemy transmisji alarmow / Alarm transmission and fault warning routing equipment, Systemy kontroli dostepu / Access control systems, Systemy wlamaniowe / Alarm and electronic security systems, Systemy oswietlenia awaryjnego / Emergency lighting systems, Urzadzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Odpornosc na pole elektromagnetyczne o czestotliwosci radiowej w zakresie czestotliwosci od 10 MHz do 2 GHz przy natezeniu pola do 30 V/m oraz w zakresie czestotliwosci od 10 MHz do 4,2 GHz przy natezeniu pola do 10 V/m / Radiated, radio-frequency, electromagnetic field immunity test (frequency from 10 MHz to 2 GHz for 30 V/m field strength, frequency from 10 MHz to 4,2 GHz for 10 V/m field strength), Badania w komorze GTEM dla urzadzen o maksymalnych wymiarach (szer. x gl. x wys.) / Tests in the GTEM cell for devices with maximum dimensions (width x depth x height) 30 cm x 15 cm x 30 cm PN-EN 61000-4-3:2007+A1:2008 +A2:2011+IS1:2009 (EN 61000-4-3:2006+A1:2008 +A2:2010+IS1:2009 IEC 61000-4-3:2006+AMD1:2007 +AMD2:2010+IS1:2009) | PN-EN IEC 61000-4-3:2021-06 (EN IEC 61000-4-3:2020 IEC 61000-4-3:2020) | PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003) | PN-EN 50130-4:2012+A1:2015-03 p. 10 (EN 50130-4:2011+A1:2014 p. 10) | IEC 62599-2:2010-05","categories":["electronics"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbc2","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems","methodology":"Odporność na zakłócenia serią szybkich elektrycznych stanów przejściowych / Electrical fast transient/burst immunity test","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zakłócenia serią szybkich elektrycznych stanów przejściowych / Electrical fast transient/burst immunity test","reference":"PN-EN 61000-4-4:2013-05 (EN 61000-4-4:2012 IEC 61000-4-4:2012) | PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003) | PN-EN 50130-4:2012+A1:2015-03 p. 12 (EN 50130-4:2011+A1:2014 p. 12) | IEC 62599-2:2010-05","norm_bases":["PN-EN 61000-4-4:2013-05 (EN 61000-4-4:2012 IEC 61000-4-4:2012)","PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003)","PN-EN 50130-4:2012+A1:2015-03 p. 12 (EN 50130-4:2011+A1:2014 p. 12)","IEC 62599-2:2010-05"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Odporność na zakłócenia serią szybkich elektrycznych stanów przejściowych / Electrical fast transient/burst immunity test PN-EN 61000-4-4:2013-05 (EN 61000-4-4:2012 IEC 61000-4-4:2012) | PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003) | PN-EN 50130-4:2012+A1:2015-03 p. 12 (EN 50130-4:2011+A1:2014 p. 12) | IEC 62599-2:2010-05 Systemy sygnalizacji pozarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepla / Electrical smoke and heat control systems, Dzwiekowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujace / Integrating fire devices systems, Systemy transmisji alarmow / Alarm transmission and fault warning routing equipment, Systemy kontroli dostepu / Access control systems, Systemy wlamaniowe / Alarm and electronic security systems, Systemy oswietlenia awaryjnego / Emergency lighting systems, Urzadzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Odpornosc na zaklocenia seria szybkich elektrycznych stanow przejsciowych / Electrical fast transient/burst immunity test PN-EN 61000-4-4:2013-05 (EN 61000-4-4:2012 IEC 61000-4-4:2012) | PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003) | PN-EN 50130-4:2012+A1:2015-03 p. 12 (EN 50130-4:2011+A1:2014 p. 12) | IEC 62599-2:2010-05","categories":["electronics"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbc3","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems","methodology":"Odporność na udary (zakłócenia impulsowe dużej energii) / Surge immunity test","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na udary (zakłócenia impulsowe dużej energii) / Surge immunity test","reference":"PN-EN 61000-4-5:2010 (EN 61000-4-5:2006 IEC 61000-4-5:2005) | PN-EN 61000-4-5:2014-10+A1:2018-01 (EN 61000-4-5:2014+A1:2017 IEC 61000-4-5:2014+AMD1:2017) | PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003) | PN-EN 50130-4:2012+A1:2015-03 p. 13 (EN 50130-4:2011+A1:2014 p. 13) | IEC 62599-2:2010-05","norm_bases":["PN-EN 61000-4-5:2010 (EN 61000-4-5:2006 IEC 61000-4-5:2005)","PN-EN 61000-4-5:2014-10+A1:2018-01 (EN 61000-4-5:2014+A1:2017 IEC 61000-4-5:2014+AMD1:2017)","PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003)","PN-EN 50130-4:2012+A1:2015-03 p. 13 (EN 50130-4:2011+A1:2014 p. 13)","IEC 62599-2:2010-05"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Odporność na udary (zakłócenia impulsowe dużej energii) / Surge immunity test PN-EN 61000-4-5:2010 (EN 61000-4-5:2006 IEC 61000-4-5:2005) | PN-EN 61000-4-5:2014-10+A1:2018-01 (EN 61000-4-5:2014+A1:2017 IEC 61000-4-5:2014+AMD1:2017) | PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003) | PN-EN 50130-4:2012+A1:2015-03 p. 13 (EN 50130-4:2011+A1:2014 p. 13) | IEC 62599-2:2010-05 Systemy sygnalizacji pozarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepla / Electrical smoke and heat control systems, Dzwiekowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujace / Integrating fire devices systems, Systemy transmisji alarmow / Alarm transmission and fault warning routing equipment, Systemy kontroli dostepu / Access control systems, Systemy wlamaniowe / Alarm and electronic security systems, Systemy oswietlenia awaryjnego / Emergency lighting systems, Urzadzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Odpornosc na udary (zaklocenia impulsowe duzej energii) / Surge immunity test PN-EN 61000-4-5:2010 (EN 61000-4-5:2006 IEC 61000-4-5:2005) | PN-EN 61000-4-5:2014-10+A1:2018-01 (EN 61000-4-5:2014+A1:2017 IEC 61000-4-5:2014+AMD1:2017) | PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003) | PN-EN 50130-4:2012+A1:2015-03 p. 13 (EN 50130-4:2011+A1:2014 p. 13) | IEC 62599-2:2010-05","categories":["electronics"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbc4","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems","methodology":"Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej (zakłócenia sinusoidalne przewodzone) w zakresie częstotliwości 150 kHz - 230 MHz / Immunity test to conducted disturbances, induced by radio-frequency fields, frequency range 150 kHz - 230 MHz","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej (zakłócenia sinusoidalne przewodzone) w zakresie częstotliwości 150 kHz - 230 MHz / Immunity test to conducted disturbances, induced by radio-frequency fields, frequency range 150 kHz - 230 MHz","reference":"PN-EN 61000-4-6:2014-04 (EN 61000-4-6:2014 IEC 61000-4-6:2013) | PN-EN IEC 61000-4-6:2024-03 (EN IEC 61000-4-6:2023 IEC 61000-4-6:2023) | PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003) | PN-EN 50130-4:2012+A1:2015-03 p. 11 (EN 50130-4:2011+A1:2014 p. 11) | IEC 62599-2:2010-05","norm_bases":["PN-EN 61000-4-6:2014-04 (EN 61000-4-6:2014 IEC 61000-4-6:2013)","PN-EN IEC 61000-4-6:2024-03 (EN IEC 61000-4-6:2023 IEC 61000-4-6:2023)","PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003)","PN-EN 50130-4:2012+A1:2015-03 p. 11 (EN 50130-4:2011+A1:2014 p. 11)","IEC 62599-2:2010-05"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Odporność na zaburzenia przewodzone, indukowane przez pola o częstotliwości radiowej (zakłócenia sinusoidalne przewodzone) w zakresie częstotliwości 150 kHz - 230 MHz / Immunity test to conducted disturbances, induced by radio-frequency fields, frequency range 150 kHz - 230 MHz PN-EN 61000-4-6:2014-04 (EN 61000-4-6:2014 IEC 61000-4-6:2013) | PN-EN IEC 61000-4-6:2024-03 (EN IEC 61000-4-6:2023 IEC 61000-4-6:2023) | PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003) | PN-EN 50130-4:2012+A1:2015-03 p. 11 (EN 50130-4:2011+A1:2014 p. 11) | IEC 62599-2:2010-05 Systemy sygnalizacji pozarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepla / Electrical smoke and heat control systems, Dzwiekowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujace / Integrating fire devices systems, Systemy transmisji alarmow / Alarm transmission and fault warning routing equipment, Systemy kontroli dostepu / Access control systems, Systemy wlamaniowe / Alarm and electronic security systems, Systemy oswietlenia awaryjnego / Emergency lighting systems, Urzadzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Odpornosc na zaburzenia przewodzone, indukowane przez pola o czestotliwosci radiowej (zaklocenia sinusoidalne przewodzone) w zakresie czestotliwosci 150 kHz - 230 MHz / Immunity test to conducted disturbances, induced by radio-frequency fields, frequency range 150 kHz - 230 MHz PN-EN 61000-4-6:2014-04 (EN 61000-4-6:2014 IEC 61000-4-6:2013) | PN-EN IEC 61000-4-6:2024-03 (EN IEC 61000-4-6:2023 IEC 61000-4-6:2023) | PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003) | PN-EN 50130-4:2012+A1:2015-03 p. 11 (EN 50130-4:2011+A1:2014 p. 11) | IEC 62599-2:2010-05","categories":["electronics"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbc5","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems","methodology":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia / Voltage dips, short interruptions and voltage variations immunity tests","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia / Voltage dips, short interruptions and voltage variations immunity tests","reference":"PN-EN IEC 61000-4-11:2020-11 +AC:2020-12+AC:2023-01 (EN IEC 61000-4-11:2020 +AC:2020-06+AC:2022-10, IEC 61000-4-11:2020+COR1:2020+ COR2:2022) | PN-EN 61000-4-11:2007+A1:2017-09 (EN 61000-4-11:2004+A1:2017 IEC 61000-4-11:2004+AMD1:2017) | PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003) | PN-EN 50130-4:2012+A1:2015-03 p. 7, 8 (EN 50130-4:2011+A1:2014 p. 7, 8) | IEC 62599-2:2010-05","norm_bases":["PN-EN IEC 61000-4-11:2020-11 +AC:2020-12+AC:2023-01 (EN IEC 61000-4-11:2020 +AC:2020-06+AC:2022-10, IEC 61000-4-11:2020+COR1:2020+ COR2:2022)","PN-EN 61000-4-11:2007+A1:2017-09 (EN 61000-4-11:2004+A1:2017 IEC 61000-4-11:2004+AMD1:2017)","PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003)","PN-EN 50130-4:2012+A1:2015-03 p. 7, 8 (EN 50130-4:2011+A1:2014 p. 7, 8)","IEC 62599-2:2010-05"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia / Voltage dips, short interruptions and voltage variations immunity tests PN-EN IEC 61000-4-11:2020-11 +AC:2020-12+AC:2023-01 (EN IEC 61000-4-11:2020 +AC:2020-06+AC:2022-10, IEC 61000-4-11:2020+COR1:2020+ COR2:2022) | PN-EN 61000-4-11:2007+A1:2017-09 (EN 61000-4-11:2004+A1:2017 IEC 61000-4-11:2004+AMD1:2017) | PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003) | PN-EN 50130-4:2012+A1:2015-03 p. 7, 8 (EN 50130-4:2011+A1:2014 p. 7, 8) | IEC 62599-2:2010-05 Systemy sygnalizacji pozarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepla / Electrical smoke and heat control systems, Dzwiekowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujace / Integrating fire devices systems, Systemy transmisji alarmow / Alarm transmission and fault warning routing equipment, Systemy kontroli dostepu / Access control systems, Systemy wlamaniowe / Alarm and electronic security systems, Systemy oswietlenia awaryjnego / Emergency lighting systems, Urzadzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Odpornosc na zapady napiecia, krotkie przerwy i zmiany napiecia / Voltage dips, short interruptions and voltage variations immunity tests PN-EN IEC 61000-4-11:2020-11 +AC:2020-12+AC:2023-01 (EN IEC 61000-4-11:2020 +AC:2020-06+AC:2022-10, IEC 61000-4-11:2020+COR1:2020+ COR2:2022) | PN-EN 61000-4-11:2007+A1:2017-09 (EN 61000-4-11:2004+A1:2017 IEC 61000-4-11:2004+AMD1:2017) | PN-EN 50130-4:2002+A2:2007 (EN 50130-4:1995+A1:1998+A2:2003) | PN-EN 50130-4:2012+A1:2015-03 p. 7, 8 (EN 50130-4:2011+A1:2014 p. 7, 8) | IEC 62599-2:2010-05","categories":["electronics"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbc6","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems","methodology":"Emisja zaburzeń radioelektrycznych w zakresie częstotliwości od 150 kHz do 1GHz / Radio disturbance emission test, Badania w komorze GTEM dla urządzeń o maksymalnych wymiarach (szer. x gł. x wys.) 30 cm x 15 cm x 30 cm / Tests in the GTEM cell for devices with maximum dimensions (width x depth x height) 30 cm x 15 cm x 30 cm","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń radioelektrycznych w zakresie częstotliwości od 150 kHz do 1GHz / Radio disturbance emission test, Badania w komorze GTEM dla urządzeń o maksymalnych wymiarach (szer. x gł. x wys.) 30 cm x 15 cm x 30 cm / Tests in the GTEM cell for devices with maximum dimensions (width x depth x height) 30 cm x 15 cm x 30 cm","reference":"PN-EN 55022:2011 (CISPR 22:2008 EN 55022:2010+AC:2011) | PN-EN 55014-1:2012 (CISPR 14-1:2005 EN 55014-1:2006+A1:2009+A2:2011) | PN-EN 55014-2:1999+A1:2004 +A2:2009+ IS1:2007 (CISPR 14-2:1997 EN 55014-2:1997+A1:2001 +A2:2008+IS1:2007) | PN-CISPR 16-2:1999 (CISPR 16-2:1996)","norm_bases":["PN-EN 55022:2011 (CISPR 22:2008 EN 55022:2010+AC:2011)","PN-EN 55014-1:2012 (CISPR 14-1:2005 EN 55014-1:2006+A1:2009+A2:2011)","PN-EN 55014-2:1999+A1:2004 +A2:2009+ IS1:2007 (CISPR 14-2:1997 EN 55014-2:1997+A1:2001 +A2:2008+IS1:2007)","PN-CISPR 16-2:1999 (CISPR 16-2:1996)"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Systemy sygnalizacji pożarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepła / Electrical smoke and heat control systems, Dźwiękowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujące / Integrating fire devices systems, Systemy transmisji alarmów / Alarm transmission and fault warning routing equipment, Systemy kontroli dostępu / Access control systems, Systemy włamaniowe / Alarm and electronic security systems, Systemy oświetlenia awaryjnego / Emergency lighting systems, Urządzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Emisja zaburzeń radioelektrycznych w zakresie częstotliwości od 150 kHz do 1GHz / Radio disturbance emission test, Badania w komorze GTEM dla urządzeń o maksymalnych wymiarach (szer. x gł. x wys.) 30 cm x 15 cm x 30 cm / Tests in the GTEM cell for devices with maximum dimensions (width x depth x height) 30 cm x 15 cm x 30 cm PN-EN 55022:2011 (CISPR 22:2008 EN 55022:2010+AC:2011) | PN-EN 55014-1:2012 (CISPR 14-1:2005 EN 55014-1:2006+A1:2009+A2:2011) | PN-EN 55014-2:1999+A1:2004 +A2:2009+ IS1:2007 (CISPR 14-2:1997 EN 55014-2:1997+A1:2001 +A2:2008+IS1:2007) | PN-CISPR 16-2:1999 (CISPR 16-2:1996) Systemy sygnalizacji pozarowej / Fire detection and fire alarm systems, Elektryczne systemy sterowania gaszeniem / Electrical fixed firefighting systems, Elektryczne systemy rozprzestrzeniania dymu i ciepla / Electrical smoke and heat control systems, Dzwiekowe systemy ostrzegawcze / Voice alarm systems, Systemy integrujace / Integrating fire devices systems, Systemy transmisji alarmow / Alarm transmission and fault warning routing equipment, Systemy kontroli dostepu / Access control systems, Systemy wlamaniowe / Alarm and electronic security systems, Systemy oswietlenia awaryjnego / Emergency lighting systems, Urzadzenia i systemy nawigacji i radiokomunikacji morskiej / Maritime navigation and radiocommunication equipment and systems Emisja zaburzen radioelektrycznych w zakresie czestotliwosci od 150 kHz do 1GHz / Radio disturbance emission test, Badania w komorze GTEM dla urzadzen o maksymalnych wymiarach (szer. x gl. x wys.) 30 cm x 15 cm x 30 cm / Tests in the GTEM cell for devices with maximum dimensions (width x depth x height) 30 cm x 15 cm x 30 cm PN-EN 55022:2011 (CISPR 22:2008 EN 55022:2010+AC:2011) | PN-EN 55014-1:2012 (CISPR 14-1:2005 EN 55014-1:2006+A1:2009+A2:2011) | PN-EN 55014-2:1999+A1:2004 +A2:2009+ IS1:2007 (CISPR 14-2:1997 EN 55014-2:1997+A1:2001 +A2:2008+IS1:2007) | PN-CISPR 16-2:1999 (CISPR 16-2:1996)","categories":["environment","electronics"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbc7","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Centrala sygnalizacji pożarowej / Control and indicating equipment","methodology":"Cechy do oceny funkcjonalności centrali sygnalizacji pożarowej według Tablicy ZA.1 normy / Characteristics to functional assessment of the control and indicating equipment according to ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności centrali sygnalizacji pożarowej według Tablicy ZA.1 normy / Characteristics to functional assessment of the control and indicating equipment according to ZA.1 table of the standard","reference":"PN-EN 54-2:2002+A1:2007 (EN 54-2:1997+AC:1999+A1:2006) w tym / including: | p. 12.3 z wykorzystaniem / using PN-EN 60529:2003 | p. 15.4 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p.15.5 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 15.6 z wykorzystaniem / using PN-EN 60068-2-75: 2000 | p. 15.7, 15.15 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p.15.8 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | p.15.13 z wykorzystaniem / using PN-EN 54-4:2001+A1:2004+A2:2007 | ISO 7240-2:2017","norm_bases":["PN-EN 54-2:2002+A1:2007 (EN 54-2:1997+AC:1999+A1:2006) w tym / including:","p. 12.3 z wykorzystaniem / using PN-EN 60529:2003","p. 15.4 z wykorzystaniem / using PN-EN 60068-2-1:2009","p.15.5 z wykorzystaniem / using PN-EN 60068-2-78:2007","p. 15.6 z wykorzystaniem / using PN-EN 60068-2-75: 2000","p. 15.7, 15.15 z wykorzystaniem / using PN-EN 60068-2-6:2008","p.15.8 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007","PN-EN 50130-4:2012+A1:2015-03","p.15.13 z wykorzystaniem / using PN-EN 54-4:2001+A1:2004+A2:2007","ISO 7240-2:2017"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Centrala sygnalizacji pożarowej / Control and indicating equipment Cechy do oceny funkcjonalności centrali sygnalizacji pożarowej według Tablicy ZA.1 normy / Characteristics to functional assessment of the control and indicating equipment according to ZA.1 table of the standard PN-EN 54-2:2002+A1:2007 (EN 54-2:1997+AC:1999+A1:2006) w tym / including: | p. 12.3 z wykorzystaniem / using PN-EN 60529:2003 | p. 15.4 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p.15.5 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 15.6 z wykorzystaniem / using PN-EN 60068-2-75: 2000 | p. 15.7, 15.15 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p.15.8 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | p.15.13 z wykorzystaniem / using PN-EN 54-4:2001+A1:2004+A2:2007 | ISO 7240-2:2017 Centrala sygnalizacji pozarowej / Control and indicating equipment Cechy do oceny funkcjonalnosci centrali sygnalizacji pozarowej wedlug Tablicy ZA.1 normy / Characteristics to functional assessment of the control and indicating equipment according to ZA.1 table of the standard PN-EN 54-2:2002+A1:2007 (EN 54-2:1997+AC:1999+A1:2006) w tym / including: | p. 12.3 z wykorzystaniem / using PN-EN 60529:2003 | p. 15.4 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p.15.5 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 15.6 z wykorzystaniem / using PN-EN 60068-2-75: 2000 | p. 15.7, 15.15 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p.15.8 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | p.15.13 z wykorzystaniem / using PN-EN 54-4:2001+A1:2004+A2:2007 | ISO 7240-2:2017","categories":["other"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbc8","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Sygnalizator akustyczny / Sounder","methodology":"Cechy do oceny funkcjonalności sygnalizatora akustycznego według Tablicy ZA.1 / Characteristics to functional assessment of the sounder according to ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności sygnalizatora akustycznego według Tablicy ZA.1 / Characteristics to functional assessment of the sounder according to ZA.1 table of the standard","reference":"PN-EN 54-3:2003+A2:2007 (EN 54-3:2001+A1:2002+A2:2006) w tym / including: | p. 4.5, 4.6 i 5.17 z wykorzystaniem / using PN-EN 60529:2003 | p. 5.5 i 5.6 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.7 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.8. i 5.10 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p.5.11 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p.5.13 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p.5.14, 5.15 z wykorzystaniem / using PN-EN 60068-2-6:2002 | p. 5.16 z wykorzystaniem / using PN-EN 50130-4:2002 + A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | PN-EN 54-3:2014-12 (EN 54-3:2014) | PN-EN 54-3+A1:2019-06 (EN 54-3+A1:2019-06) w tym / including: | p. 4.2.4, 5.2.4 z wykorzystaniem / using PN-EN 60529:2003 | p. 5.4.1.1, 5.4.1.2 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.4.1.3 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.4.2.1, 5.4.2.3 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.4.2.2 z wykorzystaniem / using PN-EN 60068-2-78:2013 | p. 5.4.3.1 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.4.3.2 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p. 5.4.3.3, 5.4.3.4 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p. 5.4.4 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.4.5 z wykorzystaniem / using PN-EN 50130-4:2012+A1:2015-03","norm_bases":["PN-EN 54-3:2003+A2:2007 (EN 54-3:2001+A1:2002+A2:2006) w tym / including:","p. 4.5, 4.6 i 5.17 z wykorzystaniem / using PN-EN 60529:2003","p. 5.5 i 5.6 z wykorzystaniem / using PN-EN 60068-2-2:2009","p. 5.7 z wykorzystaniem / using PN-EN 60068-2-1:2009","p. 5.8. i 5.10 z wykorzystaniem / using PN-EN 60068-2-30:2008","p. 5.9 z wykorzystaniem / using PN-EN 60068-2-78:2007","p.5.11 z wykorzystaniem / using PN-EN 60068-2-42:2004","p. 5.12 z wykorzystaniem / using PN-EN 60068-2-27:2009","p.5.13 z wykorzystaniem / using PN-EN 60068-2-75:2000","p.5.14, 5.15 z wykorzystaniem / using PN-EN 60068-2-6:2002","p. 5.16 z wykorzystaniem / using PN-EN 50130-4:2002 + A2:2007","PN-EN 50130-4:2012+A1:2015-03","PN-EN 54-3:2014-12 (EN 54-3:2014)","PN-EN 54-3+A1:2019-06 (EN 54-3+A1:2019-06) w tym / including:","p. 4.2.4, 5.2.4 z wykorzystaniem / using PN-EN 60529:2003","p. 5.4.1.1, 5.4.1.2 z wykorzystaniem / using PN-EN 60068-2-2:2009","p. 5.4.1.3 z wykorzystaniem / using PN-EN 60068-2-1:2009","p. 5.4.2.1, 5.4.2.3 z wykorzystaniem / using PN-EN 60068-2-30:2008","p. 5.4.2.2 z wykorzystaniem / using PN-EN 60068-2-78:2013","p. 5.4.3.1 z wykorzystaniem / using PN-EN 60068-2-27:2009","p. 5.4.3.2 z wykorzystaniem / using PN-EN 60068-2-75:2000","p. 5.4.3.3, 5.4.3.4 z wykorzystaniem / using PN-EN 60068-2-6:2008","p. 5.4.4 z wykorzystaniem / using PN-EN 60068-2-42:2004","p. 5.4.5 z wykorzystaniem / using PN-EN 50130-4:2012+A1:2015-03"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sygnalizator akustyczny / Sounder Cechy do oceny funkcjonalności sygnalizatora akustycznego według Tablicy ZA.1 / Characteristics to functional assessment of the sounder according to ZA.1 table of the standard PN-EN 54-3:2003+A2:2007 (EN 54-3:2001+A1:2002+A2:2006) w tym / including: | p. 4.5, 4.6 i 5.17 z wykorzystaniem / using PN-EN 60529:2003 | p. 5.5 i 5.6 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.7 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.8. i 5.10 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p.5.11 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p.5.13 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p.5.14, 5.15 z wykorzystaniem / using PN-EN 60068-2-6:2002 | p. 5.16 z wykorzystaniem / using PN-EN 50130-4:2002 + A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | PN-EN 54-3:2014-12 (EN 54-3:2014) | PN-EN 54-3+A1:2019-06 (EN 54-3+A1:2019-06) w tym / including: | p. 4.2.4, 5.2.4 z wykorzystaniem / using PN-EN 60529:2003 | p. 5.4.1.1, 5.4.1.2 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.4.1.3 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.4.2.1, 5.4.2.3 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.4.2.2 z wykorzystaniem / using PN-EN 60068-2-78:2013 | p. 5.4.3.1 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.4.3.2 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p. 5.4.3.3, 5.4.3.4 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p. 5.4.4 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.4.5 z wykorzystaniem / using PN-EN 50130-4:2012+A1:2015-03 Sygnalizator akustyczny / Sounder Cechy do oceny funkcjonalnosci sygnalizatora akustycznego wedlug Tablicy ZA.1 / Characteristics to functional assessment of the sounder according to ZA.1 table of the standard PN-EN 54-3:2003+A2:2007 (EN 54-3:2001+A1:2002+A2:2006) w tym / including: | p. 4.5, 4.6 i 5.17 z wykorzystaniem / using PN-EN 60529:2003 | p. 5.5 i 5.6 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.7 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.8. i 5.10 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p.5.11 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p.5.13 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p.5.14, 5.15 z wykorzystaniem / using PN-EN 60068-2-6:2002 | p. 5.16 z wykorzystaniem / using PN-EN 50130-4:2002 + A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | PN-EN 54-3:2014-12 (EN 54-3:2014) | PN-EN 54-3+A1:2019-06 (EN 54-3+A1:2019-06) w tym / including: | p. 4.2.4, 5.2.4 z wykorzystaniem / using PN-EN 60529:2003 | p. 5.4.1.1, 5.4.1.2 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.4.1.3 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.4.2.1, 5.4.2.3 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.4.2.2 z wykorzystaniem / using PN-EN 60068-2-78:2013 | p. 5.4.3.1 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.4.3.2 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p. 5.4.3.3, 5.4.3.4 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p. 5.4.4 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.4.5 z wykorzystaniem / using PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbc9","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Zasilacz / Power supply equipment","methodology":"Cechy do oceny funkcjonalności zasilacza według p. 9.2, 9.3, 9.4 oraz Tablicy ZA.1 normy PN-EN 54-4:2001+A1:2004+A2:2007 / Characteristics to functional assessment of the power supply equipment according to p. 9.2, 9.3, 9.4 and ZA.1 table of EN 54-4:1997+AC:1999+A1:2002+A2:2006 standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności zasilacza według p. 9.2, 9.3, 9.4 oraz Tablicy ZA.1 normy PN-EN 54-4:2001+A1:2004+A2:2007 / Characteristics to functional assessment of the power supply equipment according to p. 9.2, 9.3, 9.4 and ZA.1 table of EN 54-4:1997+AC:1999+A1:2002+A2:2006 standard","reference":"PN-EN 54-4:2001+A1:2004+A2:2007 (EN 54-4:1997+AC:1999 +A1:2002+A2:2006) w tym / including: | p. 6.2.1 z wykorzystaniem / using PN-EN 60529:2003 | p. 9.5 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 9.6 i 9.14 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 9.7 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p. 9.8 i 9.15 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 9.9 z zastosowaniem PN-EN 50130-4:2002 + A2:2007 | PN-EN 50130-4:2012+A1:2015-03","norm_bases":["PN-EN 54-4:2001+A1:2004+A2:2007 (EN 54-4:1997+AC:1999 +A1:2002+A2:2006) w tym / including:","p. 6.2.1 z wykorzystaniem / using PN-EN 60529:2003","p. 9.5 z wykorzystaniem / using PN-EN 60068-2-1:2009","p. 9.6 i 9.14 z wykorzystaniem / using PN-EN 60068-2-78:2007","p. 9.7 z wykorzystaniem / using PN-EN 60068-2-75:2000","p. 9.8 i 9.15 z wykorzystaniem / using PN-EN 60068-2-6:2002","PN-EN 60068-2-6:2008","p. 9.9 z zastosowaniem PN-EN 50130-4:2002 + A2:2007","PN-EN 50130-4:2012+A1:2015-03"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zasilacz / Power supply equipment Cechy do oceny funkcjonalności zasilacza według p. 9.2, 9.3, 9.4 oraz Tablicy ZA.1 normy PN-EN 54-4:2001+A1:2004+A2:2007 / Characteristics to functional assessment of the power supply equipment according to p. 9.2, 9.3, 9.4 and ZA.1 table of EN 54-4:1997+AC:1999+A1:2002+A2:2006 standard PN-EN 54-4:2001+A1:2004+A2:2007 (EN 54-4:1997+AC:1999 +A1:2002+A2:2006) w tym / including: | p. 6.2.1 z wykorzystaniem / using PN-EN 60529:2003 | p. 9.5 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 9.6 i 9.14 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 9.7 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p. 9.8 i 9.15 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 9.9 z zastosowaniem PN-EN 50130-4:2002 + A2:2007 | PN-EN 50130-4:2012+A1:2015-03 Zasilacz / Power supply equipment Cechy do oceny funkcjonalnosci zasilacza wedlug p. 9.2, 9.3, 9.4 oraz Tablicy ZA.1 normy PN-EN 54-4:2001+A1:2004+A2:2007 / Characteristics to functional assessment of the power supply equipment according to p. 9.2, 9.3, 9.4 and ZA.1 table of EN 54-4:1997+AC:1999+A1:2002+A2:2006 standard PN-EN 54-4:2001+A1:2004+A2:2007 (EN 54-4:1997+AC:1999 +A1:2002+A2:2006) w tym / including: | p. 6.2.1 z wykorzystaniem / using PN-EN 60529:2003 | p. 9.5 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 9.6 i 9.14 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 9.7 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p. 9.8 i 9.15 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 9.9 z zastosowaniem PN-EN 50130-4:2002 + A2:2007 | PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbca","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Zasilacz / Power supply equipment","methodology":"Cechy do oceny funkcjonalności zasilacza według p. 4, 8, 9, 10, 11, 12.1, 12.2, 12.3, 12.4, 12.5, 12.6, 12.7, 12.8, 12.9, 12.10, 12.11, 12.13, 12.14, 12.15 oraz Tablicy ZA.1 normy PN-EN 12101-10:2007 +AC:2007 / Characteristics to functional assessment of the power supply equipment according to p. 4, 8, 9, 10, 11, 12.1, 12.2, 12.3, 12.4, 12.5, 12.6, 12.7, 12.8, 12.9, 12.10, 12.11, 12.13, 12.14, 12.15 and ZA.1 table of EN 12101-10:2005+AC:2007 standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności zasilacza według p. 4, 8, 9, 10, 11, 12.1, 12.2, 12.3, 12.4, 12.5, 12.6, 12.7, 12.8, 12.9, 12.10, 12.11, 12.13, 12.14, 12.15 oraz Tablicy ZA.1 normy PN-EN 12101-10:2007 +AC:2007 / Characteristics to functional assessment of the power supply equipment according to p. 4, 8, 9, 10, 11, 12.1, 12.2, 12.3, 12.4, 12.5, 12.6, 12.7, 12.8, 12.9, 12.10, 12.11, 12.13, 12.14, 12.15 and ZA.1 table of EN 12101-10:2005+AC:2007 standard","reference":"PN-EN 12101-10:2007+AC:2007 (EN 12101-10:2005+AC:2007) w tym / including: | p. 8, 12.13, 12.14 z wykorzystaniem / using PN-EN 60529:2003 | p. 12.4 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 12.5 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 12.6 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p.12.7 i 12.9 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p.12.8. z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 12.10 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 12.11 z wykorzystaniem / using PN-EN ISO 6988:2000 | p. 12.15 z wykorzystaniem / using PN-EN 50130-4:2002 + A2:2007 | PN-EN 50130-4:2012+A1:2015-03","norm_bases":["PN-EN 12101-10:2007+AC:2007 (EN 12101-10:2005+AC:2007) w tym / including:","p. 8, 12.13, 12.14 z wykorzystaniem / using PN-EN 60529:2003","p. 12.4 z wykorzystaniem / using PN-EN 60068-2-1:2009","p. 12.5 z wykorzystaniem / using PN-EN 60068-2-78:2007","p. 12.6 z wykorzystaniem / using PN-EN 60068-2-75:2000","p.12.7 i 12.9 z wykorzystaniem / using PN-EN 60068-2-6:2008","p.12.8. z wykorzystaniem / using PN-EN 60068-2-78:2007","p. 12.10 z wykorzystaniem / using PN-EN 60068-2-2:2009","p. 12.11 z wykorzystaniem / using PN-EN ISO 6988:2000","p. 12.15 z wykorzystaniem / using PN-EN 50130-4:2002 + A2:2007","PN-EN 50130-4:2012+A1:2015-03"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zasilacz / Power supply equipment Cechy do oceny funkcjonalności zasilacza według p. 4, 8, 9, 10, 11, 12.1, 12.2, 12.3, 12.4, 12.5, 12.6, 12.7, 12.8, 12.9, 12.10, 12.11, 12.13, 12.14, 12.15 oraz Tablicy ZA.1 normy PN-EN 12101-10:2007 +AC:2007 / Characteristics to functional assessment of the power supply equipment according to p. 4, 8, 9, 10, 11, 12.1, 12.2, 12.3, 12.4, 12.5, 12.6, 12.7, 12.8, 12.9, 12.10, 12.11, 12.13, 12.14, 12.15 and ZA.1 table of EN 12101-10:2005+AC:2007 standard PN-EN 12101-10:2007+AC:2007 (EN 12101-10:2005+AC:2007) w tym / including: | p. 8, 12.13, 12.14 z wykorzystaniem / using PN-EN 60529:2003 | p. 12.4 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 12.5 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 12.6 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p.12.7 i 12.9 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p.12.8. z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 12.10 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 12.11 z wykorzystaniem / using PN-EN ISO 6988:2000 | p. 12.15 z wykorzystaniem / using PN-EN 50130-4:2002 + A2:2007 | PN-EN 50130-4:2012+A1:2015-03 Zasilacz / Power supply equipment Cechy do oceny funkcjonalnosci zasilacza wedlug p. 4, 8, 9, 10, 11, 12.1, 12.2, 12.3, 12.4, 12.5, 12.6, 12.7, 12.8, 12.9, 12.10, 12.11, 12.13, 12.14, 12.15 oraz Tablicy ZA.1 normy PN-EN 12101-10:2007 +AC:2007 / Characteristics to functional assessment of the power supply equipment according to p. 4, 8, 9, 10, 11, 12.1, 12.2, 12.3, 12.4, 12.5, 12.6, 12.7, 12.8, 12.9, 12.10, 12.11, 12.13, 12.14, 12.15 and ZA.1 table of EN 12101-10:2005+AC:2007 standard PN-EN 12101-10:2007+AC:2007 (EN 12101-10:2005+AC:2007) w tym / including: | p. 8, 12.13, 12.14 z wykorzystaniem / using PN-EN 60529:2003 | p. 12.4 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 12.5 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 12.6 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p.12.7 i 12.9 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p.12.8. z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 12.10 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 12.11 z wykorzystaniem / using PN-EN ISO 6988:2000 | p. 12.15 z wykorzystaniem / using PN-EN 50130-4:2002 + A2:2007 | PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbcb","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Zasilacz / Power supply equipment","methodology":"Cechy do oceny funkcjonalności zasilacza według p. 4, 5, 6, 7, 8, 9 normy ISO 7240-4:2003, ISO 7240-4:2017, Characteristics to functional assessment of the power supply equipment according to 4, 5, 6, 7, 8, 9 of ISO 7240-4:2003, ISO 7240-4:2017 standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności zasilacza według p. 4, 5, 6, 7, 8, 9 normy ISO 7240-4:2003, ISO 7240-4:2017, Characteristics to functional assessment of the power supply equipment according to 4, 5, 6, 7, 8, 9 of ISO 7240-4:2003, ISO 7240-4:2017 standard","reference":"ISO 7240-4:2003 | ISO 7240-4:2017 w tym / including: | p. 6.2.1 z wykorzystaniem / using PN-EN 60529:2003 | p. 6.3.2 z wykorzystaniem / using PN-EN 60950-1:2007 +A1:2011+A11:2009+A12:2011+A2:2014- 05 | p. 9.5 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 9.6 i 9.14 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 9.7 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p. 9.8 i 9.15 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-47:2005 | p. 9.9 z zastosowaniem PN-EN 50130-4:2002 + A2:2007 | PN-EN 50130-4:2012+A1:2015-03","norm_bases":["ISO 7240-4:2003","ISO 7240-4:2017 w tym / including:","p. 6.2.1 z wykorzystaniem / using PN-EN 60529:2003","p. 6.3.2 z wykorzystaniem / using PN-EN 60950-1:2007 +A1:2011+A11:2009+A12:2011+A2:2014- 05","p. 9.5 z wykorzystaniem / using PN-EN 60068-2-1:2009","p. 9.6 i 9.14 z wykorzystaniem / using PN-EN 60068-2-78:2007","p. 9.7 z wykorzystaniem / using PN-EN 60068-2-75:2000","p. 9.8 i 9.15 z wykorzystaniem / using PN-EN 60068-2-6:2002","PN-EN 60068-2-47:2005","p. 9.9 z zastosowaniem PN-EN 50130-4:2002 + A2:2007","PN-EN 50130-4:2012+A1:2015-03"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zasilacz / Power supply equipment Cechy do oceny funkcjonalności zasilacza według p. 4, 5, 6, 7, 8, 9 normy ISO 7240-4:2003, ISO 7240-4:2017, Characteristics to functional assessment of the power supply equipment according to 4, 5, 6, 7, 8, 9 of ISO 7240-4:2003, ISO 7240-4:2017 standard ISO 7240-4:2003 | ISO 7240-4:2017 w tym / including: | p. 6.2.1 z wykorzystaniem / using PN-EN 60529:2003 | p. 6.3.2 z wykorzystaniem / using PN-EN 60950-1:2007 +A1:2011+A11:2009+A12:2011+A2:2014- 05 | p. 9.5 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 9.6 i 9.14 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 9.7 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p. 9.8 i 9.15 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-47:2005 | p. 9.9 z zastosowaniem PN-EN 50130-4:2002 + A2:2007 | PN-EN 50130-4:2012+A1:2015-03 Zasilacz / Power supply equipment Cechy do oceny funkcjonalnosci zasilacza wedlug p. 4, 5, 6, 7, 8, 9 normy ISO 7240-4:2003, ISO 7240-4:2017, Characteristics to functional assessment of the power supply equipment according to 4, 5, 6, 7, 8, 9 of ISO 7240-4:2003, ISO 7240-4:2017 standard ISO 7240-4:2003 | ISO 7240-4:2017 w tym / including: | p. 6.2.1 z wykorzystaniem / using PN-EN 60529:2003 | p. 6.3.2 z wykorzystaniem / using PN-EN 60950-1:2007 +A1:2011+A11:2009+A12:2011+A2:2014- 05 | p. 9.5 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 9.6 i 9.14 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 9.7 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p. 9.8 i 9.15 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-47:2005 | p. 9.9 z zastosowaniem PN-EN 50130-4:2002 + A2:2007 | PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbcc","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Czujka ciepła punktowa / Point heat detector","methodology":"Cechy do oceny funkcjonalności czujki ciepła punktowej według p. 5.1 oraz Tablicy ZA.1 normy, Pomiar temperatury, Characteristics to functional assessment of the point heat detector according to p. 5.1 and ZA.1 table of the standard, Temperature measurement","parameters":[{"name":"Zakres","range":"(0 - 148) °C"},{"name":"Range","range":"(0 - 148) ° C"}],"technique":"Metoda: bezpośrednia; Method: direct","techniques":["Metoda: bezpośrednia","Method: direct"],"computed":[],"activity":"Cechy do oceny funkcjonalności czujki ciepła punktowej według p. 5.1 oraz Tablicy ZA.1 normy, Pomiar temperatury, Characteristics to functional assessment of the point heat detector according to p. 5.1 and ZA.1 table of the standard, Temperature measurement\nZakres:\nZakres (0 - 148) °C\nRange (0 - 148) ° C\nMetoda: bezpośrednia; Method: direct","reference":"PN-EN 54-5:2003 (EN 54-5:2003+A1:2002) | PN-EN 54-5+A1:2018-11 (EN 54-5+A1:2018) w tym / including: | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.10. z wykorzystaniem / using PN-EN 60068-2-2:2002 | PN-EN 60068-2-2:2009 | p. 5.11 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.13. z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.14 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.16 i 5.17 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.18 z wykorzystaniem / using PN-EN 50130-4:2002 +A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | ISO 7240-5:2018","norm_bases":["PN-EN 54-5:2003 (EN 54-5:2003+A1:2002)","PN-EN 54-5+A1:2018-11 (EN 54-5+A1:2018) w tym / including:","p. 5.9 z wykorzystaniem / using PN-EN 60068-2-1:2009","p. 5.10. z wykorzystaniem / using PN-EN 60068-2-2:2002","PN-EN 60068-2-2:2009","p. 5.11 z wykorzystaniem / using PN-EN 60068-2-30:2008","p. 5.12 z wykorzystaniem / using PN-EN 60068-2-78:2007","p. 5.13. z wykorzystaniem / using PN-EN 60068-2-42:2004","p. 5.14 z wykorzystaniem / using PN-EN 60068-2-27:2009","p. 5.16 i 5.17 z wykorzystaniem / using PN-EN 60068-2-6:2002","PN-EN 60068-2-6:2008","p. 5.18 z wykorzystaniem / using PN-EN 50130-4:2002 +A2:2007","PN-EN 50130-4:2012+A1:2015-03","ISO 7240-5:2018"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Czujka ciepła punktowa / Point heat detector Cechy do oceny funkcjonalności czujki ciepła punktowej według p. 5.1 oraz Tablicy ZA.1 normy, Pomiar temperatury, Characteristics to functional assessment of the point heat detector according to p. 5.1 and ZA.1 table of the standard, Temperature measurement\nZakres:\nZakres (0 - 148) °C\nRange (0 - 148) ° C\nMetoda: bezpośrednia; Method: direct PN-EN 54-5:2003 (EN 54-5:2003+A1:2002) | PN-EN 54-5+A1:2018-11 (EN 54-5+A1:2018) w tym / including: | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.10. z wykorzystaniem / using PN-EN 60068-2-2:2002 | PN-EN 60068-2-2:2009 | p. 5.11 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.13. z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.14 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.16 i 5.17 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.18 z wykorzystaniem / using PN-EN 50130-4:2002 +A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | ISO 7240-5:2018 Czujka ciepla punktowa / Point heat detector Cechy do oceny funkcjonalnosci czujki ciepla punktowej wedlug p. 5.1 oraz Tablicy ZA.1 normy, Pomiar temperatury, Characteristics to functional assessment of the point heat detector according to p. 5.1 and ZA.1 table of the standard, Temperature measurement\nZakres:\nZakres (0 - 148) °C\nRange (0 - 148) ° C\nMetoda: bezposrednia; Method: direct PN-EN 54-5:2003 (EN 54-5:2003+A1:2002) | PN-EN 54-5+A1:2018-11 (EN 54-5+A1:2018) w tym / including: | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.10. z wykorzystaniem / using PN-EN 60068-2-2:2002 | PN-EN 60068-2-2:2009 | p. 5.11 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.13. z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.14 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.16 i 5.17 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.18 z wykorzystaniem / using PN-EN 50130-4:2002 +A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | ISO 7240-5:2018","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0 - 148) °C"},{"name":"Range","range":"(0 - 148) ° C"}],"search_en":"Range Range PN-EN 54-5:2003 (EN 54-5:2003+A1:2002) | PN-EN 54-5+A1:2018-11 (EN 54-5+A1:2018) w tym / including: | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.10. z wykorzystaniem / using PN-EN 60068-2-2:2002 | PN-EN 60068-2-2:2009 | p. 5.11 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.13. z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.14 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.16 i 5.17 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.18 z wykorzystaniem / using PN-EN 50130-4:2002 +A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | ISO 7240-5:2018","parameters_zh":[{"name":"范围","range":"(0 - 148) °C"},{"name":"范围","range":"(0 - 148) ° C"}],"search_zh":"范围 范围 PN-EN 54-5:2003 (EN 54-5:2003+A1:2002) | PN-EN 54-5+A1:2018-11 (EN 54-5+A1:2018) w tym / including: | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.10. z wykorzystaniem / using PN-EN 60068-2-2:2002 | PN-EN 60068-2-2:2009 | p. 5.11 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.13. z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.14 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.16 i 5.17 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.18 z wykorzystaniem / using PN-EN 50130-4:2002 +A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | ISO 7240-5:2018"},{"_id":"6a8369aeaf14b9c0e7b1dbcd","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Czujka dymu punktowa / Point smoke detector","methodology":"Cechy do oceny funkcjonalności czujki dymu punktowej według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the point smoke detector according to p. 5.1 and ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności czujki dymu punktowej według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the point smoke detector according to p. 5.1 and ZA.1 table of the standard","reference":"PN-EN 54-7:2004+A2:2009 (EN 54-7:2000+A2:2006) | PN-EN 54-7:2018-11 (EN 54-7:2018) w tym / including: | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.10 i 5.11 z wykorzystaniem / using PN-EN 60068-2-78:2013 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.13 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.15, 5.16 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.17 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | ISO/TS 7240-9:2012 | ISO 7240-7:2018","norm_bases":["PN-EN 54-7:2004+A2:2009 (EN 54-7:2000+A2:2006)","PN-EN 54-7:2018-11 (EN 54-7:2018) w tym / including:","p. 5.9 z wykorzystaniem / using PN-EN 60068-2-1:2009","p. 5.10 i 5.11 z wykorzystaniem / using PN-EN 60068-2-78:2013","p. 5.12 z wykorzystaniem / using PN-EN 60068-2-42:2004","p. 5.13 z wykorzystaniem / using PN-EN 60068-2-27:2009","p. 5.15, 5.16 z wykorzystaniem / using PN-EN 60068-2-6:2002","PN-EN 60068-2-6:2008","p. 5.17 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007","PN-EN 50130-4:2012+A1:2015-03","ISO/TS 7240-9:2012","ISO 7240-7:2018"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Czujka dymu punktowa / Point smoke detector Cechy do oceny funkcjonalności czujki dymu punktowej według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the point smoke detector according to p. 5.1 and ZA.1 table of the standard PN-EN 54-7:2004+A2:2009 (EN 54-7:2000+A2:2006) | PN-EN 54-7:2018-11 (EN 54-7:2018) w tym / including: | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.10 i 5.11 z wykorzystaniem / using PN-EN 60068-2-78:2013 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.13 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.15, 5.16 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.17 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | ISO/TS 7240-9:2012 | ISO 7240-7:2018 Czujka dymu punktowa / Point smoke detector Cechy do oceny funkcjonalnosci czujki dymu punktowej wedlug p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the point smoke detector according to p. 5.1 and ZA.1 table of the standard PN-EN 54-7:2004+A2:2009 (EN 54-7:2000+A2:2006) | PN-EN 54-7:2018-11 (EN 54-7:2018) w tym / including: | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.10 i 5.11 z wykorzystaniem / using PN-EN 60068-2-78:2013 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.13 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.15, 5.16 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.17 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | ISO/TS 7240-9:2012 | ISO 7240-7:2018","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbce","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Czujka dymu punktowa / Point smoke detector","methodology":"Cechy do oceny funkcjonalności czujki dymu punktowej według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the point smoke detector according to p. 5.1 and ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności czujki dymu punktowej według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the point smoke detector according to p. 5.1 and ZA.1 table of the standard","reference":"PN-EN 14604:2006+AC:2009 (EN 14604:2005+AC:2008) w tym / including: | p. 5.10 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.12, 5.13 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.14 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | p. 5.17 z wykorzystaniem / using PN-EN 54-3:2003","norm_bases":["PN-EN 14604:2006+AC:2009 (EN 14604:2005+AC:2008) w tym / including:","p. 5.10 z wykorzystaniem / using PN-EN 60068-2-42:2004","p. 5.12, 5.13 z wykorzystaniem / using PN-EN 60068-2-6:2002","PN-EN 60068-2-6:2008","p. 5.14 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007","PN-EN 50130-4:2012+A1:2015-03","p. 5.17 z wykorzystaniem / using PN-EN 54-3:2003"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Czujka dymu punktowa / Point smoke detector Cechy do oceny funkcjonalności czujki dymu punktowej według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the point smoke detector according to p. 5.1 and ZA.1 table of the standard PN-EN 14604:2006+AC:2009 (EN 14604:2005+AC:2008) w tym / including: | p. 5.10 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.12, 5.13 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.14 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | p. 5.17 z wykorzystaniem / using PN-EN 54-3:2003 Czujka dymu punktowa / Point smoke detector Cechy do oceny funkcjonalnosci czujki dymu punktowej wedlug p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the point smoke detector according to p. 5.1 and ZA.1 table of the standard PN-EN 14604:2006+AC:2009 (EN 14604:2005+AC:2008) w tym / including: | p. 5.10 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.12, 5.13 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.14 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | p. 5.17 z wykorzystaniem / using PN-EN 54-3:2003","categories":["other"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbcf","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Czujka płomienia / Point flame detector","methodology":"Cechy do oceny funkcjonalności czujki płomienia według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the point flame detector according to p. 5.1 and ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności czujki płomienia według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the point flame detector according to p. 5.1 and ZA.1 table of the standard","reference":"PN-EN 54-10:2005+A1:2006 (EN 54-10:2002+A1:2005) w tym / including: | p. 5.7 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.8 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.10 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.11 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.14, 5.15 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.17 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03","norm_bases":["PN-EN 54-10:2005+A1:2006 (EN 54-10:2002+A1:2005) w tym / including:","p. 5.7 z wykorzystaniem / using PN-EN 60068-2-2:2009","p. 5.8 z wykorzystaniem / using PN-EN 60068-2-1:2009","p. 5.9 z wykorzystaniem / using PN-EN 60068-2-30:2008","p. 5.10 z wykorzystaniem / using PN-EN 60068-2-78:2007","p. 5.11 z wykorzystaniem / using PN-EN 60068-2-42:2004","p. 5.12 z wykorzystaniem / using PN-EN 60068-2-27:2009","p. 5.14, 5.15 z wykorzystaniem / using PN-EN 60068-2-6:2002","PN-EN 60068-2-6:2008","p. 5.17 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007","PN-EN 50130-4:2012+A1:2015-03"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Czujka płomienia / Point flame detector Cechy do oceny funkcjonalności czujki płomienia według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the point flame detector according to p. 5.1 and ZA.1 table of the standard PN-EN 54-10:2005+A1:2006 (EN 54-10:2002+A1:2005) w tym / including: | p. 5.7 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.8 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.10 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.11 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.14, 5.15 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.17 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 Czujka plomienia / Point flame detector Cechy do oceny funkcjonalnosci czujki plomienia wedlug p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the point flame detector according to p. 5.1 and ZA.1 table of the standard PN-EN 54-10:2005+A1:2006 (EN 54-10:2002+A1:2005) w tym / including: | p. 5.7 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.8 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.10 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.11 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.14, 5.15 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.17 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbd0","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Ręczny ostrzegacz pożarowy / Manual call point","methodology":"Cechy do oceny funkcjonalności ręcznego ostrzegacza pożarowego według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the manual call point according to p. 5.1 and ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności ręcznego ostrzegacza pożarowego według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the manual call point according to p. 5.1 and ZA.1 table of the standard","reference":"PN-EN 54-11:2004+A1:2006 (EN 54-11:2001+A1:2005) w tym / including: | p. 4.7.1. z wykorzystaniem / using PN-EN 894-3:2002 | PN-EN 894-3+A1:2010 | p. 5.7, 5.8 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-1: 2009 | p. 5.10, 5.11 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.13 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.14 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.16, 5.17 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.18 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | p. 5.19, 5.17 z wykorzystaniem / using PN-EN 60068-2-18:2008","norm_bases":["PN-EN 54-11:2004+A1:2006 (EN 54-11:2001+A1:2005) w tym / including:","p. 4.7.1. z wykorzystaniem / using PN-EN 894-3:2002","PN-EN 894-3+A1:2010","p. 5.7, 5.8 z wykorzystaniem / using PN-EN 60068-2-2:2009","p. 5.9 z wykorzystaniem / using PN-EN 60068-2-1: 2009","p. 5.10, 5.11 z wykorzystaniem / using PN-EN 60068-2-30:2008","p. 5.12 z wykorzystaniem / using PN-EN 60068-2-78:2007","p. 5.13 z wykorzystaniem / using PN-EN 60068-2-42:2004","p. 5.14 z wykorzystaniem / using PN-EN 60068-2-27:2009","p. 5.16, 5.17 z wykorzystaniem / using PN-EN 60068-2-6:2002","PN-EN 60068-2-6:2008","p. 5.18 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007","PN-EN 50130-4:2012+A1:2015-03","p. 5.19, 5.17 z wykorzystaniem / using PN-EN 60068-2-18:2008"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ręczny ostrzegacz pożarowy / Manual call point Cechy do oceny funkcjonalności ręcznego ostrzegacza pożarowego według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the manual call point according to p. 5.1 and ZA.1 table of the standard PN-EN 54-11:2004+A1:2006 (EN 54-11:2001+A1:2005) w tym / including: | p. 4.7.1. z wykorzystaniem / using PN-EN 894-3:2002 | PN-EN 894-3+A1:2010 | p. 5.7, 5.8 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-1: 2009 | p. 5.10, 5.11 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.13 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.14 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.16, 5.17 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.18 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | p. 5.19, 5.17 z wykorzystaniem / using PN-EN 60068-2-18:2008 Reczny ostrzegacz pozarowy / Manual call point Cechy do oceny funkcjonalnosci recznego ostrzegacza pozarowego wedlug p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the manual call point according to p. 5.1 and ZA.1 table of the standard PN-EN 54-11:2004+A1:2006 (EN 54-11:2001+A1:2005) w tym / including: | p. 4.7.1. z wykorzystaniem / using PN-EN 894-3:2002 | PN-EN 894-3+A1:2010 | p. 5.7, 5.8 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-1: 2009 | p. 5.10, 5.11 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.13 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.14 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.16, 5.17 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.18 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | p. 5.19, 5.17 z wykorzystaniem / using PN-EN 60068-2-18:2008","categories":["other"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbd1","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Czujka dymu liniowa / Line smoke detector using an optical beam","methodology":"Cechy do oceny funkcjonalności czujki dymu liniowej według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the line smoke detector using an optical beam according to p. 5.1 and ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności czujki dymu liniowej według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the line smoke detector using an optical beam according to p. 5.1 and ZA.1 table of the standard","reference":"PN-EN 54-12:2005 (EN 54-12:2002) w tym / including: | p. 5.11 z wykorzystaniem / using PN-EN 60068-2-2: 2009 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.13, 5.14 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.15 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p.5.16 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | p. 5.17 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.18 z wykorzystaniem / using PN-EN 60068-2-75:2000 | ISO/TS 7240-9:2012 | ISO 7240-12:2022 | PN-EN 54-12:2015-05 (EN 54-12:2015) w tym / including: | p. 5.6.1.1 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.6.1.2 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.6.2.1, 5.6.2.2 z wykorzystaniem / using PN-EN 60068-2-78:2013 | p. 5.6.3.1 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p. 5.6.3.2 z wykorzystaniem / using PN-EN 60068-2-75:2014 | p. 5.6.4 z wykorzystaniem / using PN-EN 50130-4:2012+A1:2015-03 | p.5.6.5 z wykorzystaniem / using PN-EN 60068-2-42:2004","norm_bases":["PN-EN 54-12:2005 (EN 54-12:2002) w tym / including:","p. 5.11 z wykorzystaniem / using PN-EN 60068-2-2: 2009","p. 5.12 z wykorzystaniem / using PN-EN 60068-2-1:2009","p. 5.13, 5.14 z wykorzystaniem / using PN-EN 60068-2-78:2007","p. 5.15 z wykorzystaniem / using PN-EN 60068-2-6:2002","PN-EN 60068-2-6:2008","p.5.16 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007","PN-EN 50130-4:2012+A1:2015-03","p. 5.17 z wykorzystaniem / using PN-EN 60068-2-42:2004","p. 5.18 z wykorzystaniem / using PN-EN 60068-2-75:2000","ISO/TS 7240-9:2012","ISO 7240-12:2022","PN-EN 54-12:2015-05 (EN 54-12:2015) w tym / including:","p. 5.6.1.1 z wykorzystaniem / using PN-EN 60068-2-2:2009","p. 5.6.1.2 z wykorzystaniem / using PN-EN 60068-2-1:2009","p. 5.6.2.1, 5.6.2.2 z wykorzystaniem / using PN-EN 60068-2-78:2013","p. 5.6.3.1 z wykorzystaniem / using PN-EN 60068-2-6:2008","p. 5.6.3.2 z wykorzystaniem / using PN-EN 60068-2-75:2014","p. 5.6.4 z wykorzystaniem / using PN-EN 50130-4:2012+A1:2015-03","p.5.6.5 z wykorzystaniem / using PN-EN 60068-2-42:2004"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Czujka dymu liniowa / Line smoke detector using an optical beam Cechy do oceny funkcjonalności czujki dymu liniowej według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the line smoke detector using an optical beam according to p. 5.1 and ZA.1 table of the standard PN-EN 54-12:2005 (EN 54-12:2002) w tym / including: | p. 5.11 z wykorzystaniem / using PN-EN 60068-2-2: 2009 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.13, 5.14 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.15 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p.5.16 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | p. 5.17 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.18 z wykorzystaniem / using PN-EN 60068-2-75:2000 | ISO/TS 7240-9:2012 | ISO 7240-12:2022 | PN-EN 54-12:2015-05 (EN 54-12:2015) w tym / including: | p. 5.6.1.1 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.6.1.2 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.6.2.1, 5.6.2.2 z wykorzystaniem / using PN-EN 60068-2-78:2013 | p. 5.6.3.1 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p. 5.6.3.2 z wykorzystaniem / using PN-EN 60068-2-75:2014 | p. 5.6.4 z wykorzystaniem / using PN-EN 50130-4:2012+A1:2015-03 | p.5.6.5 z wykorzystaniem / using PN-EN 60068-2-42:2004 Czujka dymu liniowa / Line smoke detector using an optical beam Cechy do oceny funkcjonalnosci czujki dymu liniowej wedlug p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the line smoke detector using an optical beam according to p. 5.1 and ZA.1 table of the standard PN-EN 54-12:2005 (EN 54-12:2002) w tym / including: | p. 5.11 z wykorzystaniem / using PN-EN 60068-2-2: 2009 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.13, 5.14 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.15 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p.5.16 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | p. 5.17 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.18 z wykorzystaniem / using PN-EN 60068-2-75:2000 | ISO/TS 7240-9:2012 | ISO 7240-12:2022 | PN-EN 54-12:2015-05 (EN 54-12:2015) w tym / including: | p. 5.6.1.1 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.6.1.2 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.6.2.1, 5.6.2.2 z wykorzystaniem / using PN-EN 60068-2-78:2013 | p. 5.6.3.1 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p. 5.6.3.2 z wykorzystaniem / using PN-EN 60068-2-75:2014 | p. 5.6.4 z wykorzystaniem / using PN-EN 50130-4:2012+A1:2015-03 | p.5.6.5 z wykorzystaniem / using PN-EN 60068-2-42:2004","categories":["other"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbd2","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"System sygnalizacji pożarowej / Fire detection and fire alarm system","methodology":"Cechy do oceny kompatybilności możliwości przyłączenia podzespołów systemu według normy / Characteristics to functional assessment of the fire detection and fire alarm system according to the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny kompatybilności możliwości przyłączenia podzespołów systemu według normy / Characteristics to functional assessment of the fire detection and fire alarm system according to the standard","reference":"PN-EN 54-13:2017-05 (EN 54-13:2017) | PN-EN 54-13+A1:2020-05 (EN 54- 13:2017 +A1:2019)","norm_bases":["PN-EN 54-13:2017-05 (EN 54-13:2017)","PN-EN 54-13+A1:2020-05 (EN 54- 13:2017 +A1:2019)"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"System sygnalizacji pożarowej / Fire detection and fire alarm system Cechy do oceny kompatybilności możliwości przyłączenia podzespołów systemu według normy / Characteristics to functional assessment of the fire detection and fire alarm system according to the standard PN-EN 54-13:2017-05 (EN 54-13:2017) | PN-EN 54-13+A1:2020-05 (EN 54- 13:2017 +A1:2019) System sygnalizacji pozarowej / Fire detection and fire alarm system Cechy do oceny kompatybilnosci mozliwosci przylaczenia podzespolow systemu wedlug normy / Characteristics to functional assessment of the fire detection and fire alarm system according to the standard PN-EN 54-13:2017-05 (EN 54-13:2017) | PN-EN 54-13+A1:2020-05 (EN 54- 13:2017 +A1:2019)","categories":["other"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbd3","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Centrala dźwiękowego systemu ostrzegawczego / Voice alarm control and indicating equipment","methodology":"Cechy i właściwości do oceny funkcjonalności centrali dźwiękowego systemu ostrzegawczego według p. 15, 16.2 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the voice alarm control and indicating equipment according to p. 15, 16.2 and ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości do oceny funkcjonalności centrali dźwiękowego systemu ostrzegawczego według p. 15, 16.2 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the voice alarm control and indicating equipment according to p. 15, 16.2 and ZA.1 table of the standard","reference":"PN-EN 54-16:2011 (EN 54-16:2008) w tym / including: | p. 13.3.1 z wykorzystaniem / using PN-EN 60529:2003 | p. 16.8 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 16. 9, 16.10 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 16.11 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p. 16.12, 16.13 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p. 16.14 z wykorzystaniem / using PN-EN 54-4:2001+A1:2004+A2:2007 | p. 16.15 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | ISO 7240-16:2007","norm_bases":["PN-EN 54-16:2011 (EN 54-16:2008) w tym / including:","p. 13.3.1 z wykorzystaniem / using PN-EN 60529:2003","p. 16.8 z wykorzystaniem / using PN-EN 60068-2-1:2009","p. 16. 9, 16.10 z wykorzystaniem / using PN-EN 60068-2-78:2007","p. 16.11 z wykorzystaniem / using PN-EN 60068-2-75:2000","p. 16.12, 16.13 z wykorzystaniem / using PN-EN 60068-2-6:2008","p. 16.14 z wykorzystaniem / using PN-EN 54-4:2001+A1:2004+A2:2007","p. 16.15 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007","PN-EN 50130-4:2012+A1:2015-03","ISO 7240-16:2007"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Centrala dźwiękowego systemu ostrzegawczego / Voice alarm control and indicating equipment Cechy i właściwości do oceny funkcjonalności centrali dźwiękowego systemu ostrzegawczego według p. 15, 16.2 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the voice alarm control and indicating equipment according to p. 15, 16.2 and ZA.1 table of the standard PN-EN 54-16:2011 (EN 54-16:2008) w tym / including: | p. 13.3.1 z wykorzystaniem / using PN-EN 60529:2003 | p. 16.8 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 16. 9, 16.10 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 16.11 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p. 16.12, 16.13 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p. 16.14 z wykorzystaniem / using PN-EN 54-4:2001+A1:2004+A2:2007 | p. 16.15 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | ISO 7240-16:2007 Centrala dzwiekowego systemu ostrzegawczego / Voice alarm control and indicating equipment Cechy i wlasciwosci do oceny funkcjonalnosci centrali dzwiekowego systemu ostrzegawczego wedlug p. 15, 16.2 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the voice alarm control and indicating equipment according to p. 15, 16.2 and ZA.1 table of the standard PN-EN 54-16:2011 (EN 54-16:2008) w tym / including: | p. 13.3.1 z wykorzystaniem / using PN-EN 60529:2003 | p. 16.8 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 16. 9, 16.10 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 16.11 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p. 16.12, 16.13 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p. 16.14 z wykorzystaniem / using PN-EN 54-4:2001+A1:2004+A2:2007 | p. 16.15 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | ISO 7240-16:2007","categories":["other"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbd4","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Izolator zwarć / Short-circuit isolator","methodology":"Cechy i właściwości do oceny funkcjonalności izolatora zwarć według p. 5.1.5 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the short-circuit isolator according to p. 5.1.5 and ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości do oceny funkcjonalności izolatora zwarć według p. 5.1.5 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the short-circuit isolator according to p. 5.1.5 and ZA.1 table of the standard","reference":"PN-EN 54-17:2007 (EN 54-17:2005) w tym / including: | p. 5.4 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.5 z wykorzystaniem / using PN-EN 60068-2-1:2009 p. 5.6 | PN-EN 60068-2-30:2008 | p. 5.7 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.8 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.11, 5.12 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.13 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03","norm_bases":["PN-EN 54-17:2007 (EN 54-17:2005) w tym / including:","p. 5.4 z wykorzystaniem / using PN-EN 60068-2-2:2009","p. 5.5 z wykorzystaniem / using PN-EN 60068-2-1:2009 p. 5.6","PN-EN 60068-2-30:2008","p. 5.7 z wykorzystaniem / using PN-EN 60068-2-78:2007","p. 5.8 z wykorzystaniem / using PN-EN 60068-2-42:2004","p. 5.9 z wykorzystaniem / using PN-EN 60068-2-27:2009","p. 5.11, 5.12 z wykorzystaniem / using PN-EN 60068-2-6:2002","PN-EN 60068-2-6:2008","p. 5.13 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007","PN-EN 50130-4:2012+A1:2015-03"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Izolator zwarć / Short-circuit isolator Cechy i właściwości do oceny funkcjonalności izolatora zwarć według p. 5.1.5 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the short-circuit isolator according to p. 5.1.5 and ZA.1 table of the standard PN-EN 54-17:2007 (EN 54-17:2005) w tym / including: | p. 5.4 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.5 z wykorzystaniem / using PN-EN 60068-2-1:2009 p. 5.6 | PN-EN 60068-2-30:2008 | p. 5.7 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.8 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.11, 5.12 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.13 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 Izolator zwarc / Short-circuit isolator Cechy i wlasciwosci do oceny funkcjonalnosci izolatora zwarc wedlug p. 5.1.5 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the short-circuit isolator according to p. 5.1.5 and ZA.1 table of the standard PN-EN 54-17:2007 (EN 54-17:2005) w tym / including: | p. 5.4 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.5 z wykorzystaniem / using PN-EN 60068-2-1:2009 p. 5.6 | PN-EN 60068-2-30:2008 | p. 5.7 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.8 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.11, 5.12 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.13 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbd5","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Urządzenie wejścia/wyjścia / Input/output device","methodology":"Cechy i właściwości do oceny funkcjonalności urządzenia wejścia/wyjścia według p. 4, 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the input/output device according to p. 4, 5.1 and ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości do oceny funkcjonalności urządzenia wejścia/wyjścia według p. 4, 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the input/output device according to p. 4, 5.1 and ZA.1 table of the standard","reference":"PN-EN 54-18:2007+AC:2007 (EN 54-18:2005+AC:2007) w tym / including: | p. 5.3 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.4 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.5 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.6 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.7 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p.5.8 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-75: 2000 | p. 5.10, 5.11 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.12 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03","norm_bases":["PN-EN 54-18:2007+AC:2007 (EN 54-18:2005+AC:2007) w tym / including:","p. 5.3 z wykorzystaniem / using PN-EN 60068-2-2:2009","p. 5.4 z wykorzystaniem / using PN-EN 60068-2-1:2009","p. 5.5 z wykorzystaniem / using PN-EN 60068-2-30:2008","p. 5.6 z wykorzystaniem / using PN-EN 60068-2-78:2007","p. 5.7 z wykorzystaniem / using PN-EN 60068-2-42:2004","p.5.8 z wykorzystaniem / using PN-EN 60068-2-27:2009","p. 5.9 z wykorzystaniem / using PN-EN 60068-2-75: 2000","p. 5.10, 5.11 z wykorzystaniem / using PN-EN 60068-2-6:2002","PN-EN 60068-2-6:2008","p. 5.12 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007","PN-EN 50130-4:2012+A1:2015-03"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenie wejścia/wyjścia / Input/output device Cechy i właściwości do oceny funkcjonalności urządzenia wejścia/wyjścia według p. 4, 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the input/output device according to p. 4, 5.1 and ZA.1 table of the standard PN-EN 54-18:2007+AC:2007 (EN 54-18:2005+AC:2007) w tym / including: | p. 5.3 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.4 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.5 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.6 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.7 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p.5.8 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-75: 2000 | p. 5.10, 5.11 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.12 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 Urzadzenie wejscia/wyjscia / Input/output device Cechy i wlasciwosci do oceny funkcjonalnosci urzadzenia wejscia/wyjscia wedlug p. 4, 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the input/output device according to p. 4, 5.1 and ZA.1 table of the standard PN-EN 54-18:2007+AC:2007 (EN 54-18:2005+AC:2007) w tym / including: | p. 5.3 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.4 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.5 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.6 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.7 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p.5.8 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-75: 2000 | p. 5.10, 5.11 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.12 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbd6","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Czujka dymu zasysająca / Aspirating smoke detectors","methodology":"Cechy i właściwości do oceny funkcjonalności czujki dymu zasysającej według p. 6.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the aspirating smoke detectors according to p. 6.1 and ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości do oceny funkcjonalności czujki dymu zasysającej według p. 6.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the aspirating smoke detectors according to p. 6.1 and ZA.1 table of the standard","reference":"PN-EN 54-20:2010 (EN 54-20:2006+AC:2008) w tym / including: | p. 5.7 z wykorzystaniem / using PN-EN 61386-1:2011 | p. 6.5 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 6.6 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 6.7, 6.8 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 6.9 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 6.10 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 6.11 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p. 6.12, 6.13 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 6.14 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03","norm_bases":["PN-EN 54-20:2010 (EN 54-20:2006+AC:2008) w tym / including:","p. 5.7 z wykorzystaniem / using PN-EN 61386-1:2011","p. 6.5 z wykorzystaniem / using PN-EN 60068-2-2:2009","p. 6.6 z wykorzystaniem / using PN-EN 60068-2-1:2009","p. 6.7, 6.8 z wykorzystaniem / using PN-EN 60068-2-78:2007","p. 6.9 z wykorzystaniem / using PN-EN 60068-2-42:2004","p. 6.10 z wykorzystaniem / using PN-EN 60068-2-27:2009","p. 6.11 z wykorzystaniem / using PN-EN 60068-2-75:2000","p. 6.12, 6.13 z wykorzystaniem / using PN-EN 60068-2-6:2002","PN-EN 60068-2-6:2008","p. 6.14 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007","PN-EN 50130-4:2012+A1:2015-03"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Czujka dymu zasysająca / Aspirating smoke detectors Cechy i właściwości do oceny funkcjonalności czujki dymu zasysającej według p. 6.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the aspirating smoke detectors according to p. 6.1 and ZA.1 table of the standard PN-EN 54-20:2010 (EN 54-20:2006+AC:2008) w tym / including: | p. 5.7 z wykorzystaniem / using PN-EN 61386-1:2011 | p. 6.5 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 6.6 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 6.7, 6.8 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 6.9 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 6.10 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 6.11 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p. 6.12, 6.13 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 6.14 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 Czujka dymu zasysajaca / Aspirating smoke detectors Cechy i wlasciwosci do oceny funkcjonalnosci czujki dymu zasysajacej wedlug p. 6.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the aspirating smoke detectors according to p. 6.1 and ZA.1 table of the standard PN-EN 54-20:2010 (EN 54-20:2006+AC:2008) w tym / including: | p. 5.7 z wykorzystaniem / using PN-EN 61386-1:2011 | p. 6.5 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 6.6 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 6.7, 6.8 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 6.9 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 6.10 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 6.11 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p. 6.12, 6.13 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 6.14 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbd7","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Urządzenia i systemy transmisji alarmu / Alarm transmission and fault warning routing equipment","methodology":"Cechy i właściwości do oceny funkcjonalności urządzenia i systemu transmisji alarmu według p. 6, 10.2 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the alarm transmission and fault warning routing equipment according to p. 6, 10.2 and ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości do oceny funkcjonalności urządzenia i systemu transmisji alarmu według p. 6, 10.2 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the alarm transmission and fault warning routing equipment according to p. 6, 10.2 and ZA.1 table of the standard","reference":"PN-EN 54-21:2009 (EN 54-21:2006) w tym / including: | p. 7.3.1 z wykorzystaniem / using PN-EN 60529:2003 | p. 10.4 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 10.5, 10.10 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 10.6 z wykorzystaniem / using PN-EN 60068-2-75: 2000 | p. 10.7, 10.11 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 10.8 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | p.10.9 z wykorzystaniem / using PN-EN 54-4:2001+A1:2004+A2:2007 | PN-EN 50136-1-1:2007 | PN-EN 50136-1-1:2007/A2:2009 | PN-EN 50136-1-2:2007 | PN-EN 50136-1-3:2007 | PN-EN 50136-1:2012 | PN-EN 50136-2-1:2007 | PN-EN 50136-2-2:2007 | PN-EN 50136-2-3:2007","norm_bases":["PN-EN 54-21:2009 (EN 54-21:2006) w tym / including:","p. 7.3.1 z wykorzystaniem / using PN-EN 60529:2003","p. 10.4 z wykorzystaniem / using PN-EN 60068-2-1:2009","p. 10.5, 10.10 z wykorzystaniem / using PN-EN 60068-2-78:2007","p. 10.6 z wykorzystaniem / using PN-EN 60068-2-75: 2000","p. 10.7, 10.11 z wykorzystaniem / using PN-EN 60068-2-6:2002","PN-EN 60068-2-6:2008","p. 10.8 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007","PN-EN 50130-4:2012+A1:2015-03","p.10.9 z wykorzystaniem / using PN-EN 54-4:2001+A1:2004+A2:2007","PN-EN 50136-1-1:2007","PN-EN 50136-1-1:2007/A2:2009","PN-EN 50136-1-2:2007","PN-EN 50136-1-3:2007","PN-EN 50136-1:2012","PN-EN 50136-2-1:2007","PN-EN 50136-2-2:2007","PN-EN 50136-2-3:2007"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia i systemy transmisji alarmu / Alarm transmission and fault warning routing equipment Cechy i właściwości do oceny funkcjonalności urządzenia i systemu transmisji alarmu według p. 6, 10.2 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the alarm transmission and fault warning routing equipment according to p. 6, 10.2 and ZA.1 table of the standard PN-EN 54-21:2009 (EN 54-21:2006) w tym / including: | p. 7.3.1 z wykorzystaniem / using PN-EN 60529:2003 | p. 10.4 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 10.5, 10.10 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 10.6 z wykorzystaniem / using PN-EN 60068-2-75: 2000 | p. 10.7, 10.11 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 10.8 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | p.10.9 z wykorzystaniem / using PN-EN 54-4:2001+A1:2004+A2:2007 | PN-EN 50136-1-1:2007 | PN-EN 50136-1-1:2007/A2:2009 | PN-EN 50136-1-2:2007 | PN-EN 50136-1-3:2007 | PN-EN 50136-1:2012 | PN-EN 50136-2-1:2007 | PN-EN 50136-2-2:2007 | PN-EN 50136-2-3:2007 Urzadzenia i systemy transmisji alarmu / Alarm transmission and fault warning routing equipment Cechy i wlasciwosci do oceny funkcjonalnosci urzadzenia i systemu transmisji alarmu wedlug p. 6, 10.2 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the alarm transmission and fault warning routing equipment according to p. 6, 10.2 and ZA.1 table of the standard PN-EN 54-21:2009 (EN 54-21:2006) w tym / including: | p. 7.3.1 z wykorzystaniem / using PN-EN 60529:2003 | p. 10.4 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 10.5, 10.10 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 10.6 z wykorzystaniem / using PN-EN 60068-2-75: 2000 | p. 10.7, 10.11 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 10.8 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | p.10.9 z wykorzystaniem / using PN-EN 54-4:2001+A1:2004+A2:2007 | PN-EN 50136-1-1:2007 | PN-EN 50136-1-1:2007/A2:2009 | PN-EN 50136-1-2:2007 | PN-EN 50136-1-3:2007 | PN-EN 50136-1:2012 | PN-EN 50136-2-1:2007 | PN-EN 50136-2-2:2007 | PN-EN 50136-2-3:2007","categories":["other"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbd8","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Liniowa kasowalna czujka ciepła / Resettable line-type heat detector","methodology":"Cechy i właściwości do oceny funkcjonalności kasowalnej czujki ciepła według p. 4.1, 5, 7, 8 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the resettable line-type heat detector according to p. 4.1, 5, 7, 8 and ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości do oceny funkcjonalności kasowalnej czujki ciepła według p. 4.1, 5, 7, 8 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the resettable line-type heat detector according to p. 4.1, 5, 7, 8 and ZA.1 table of the standard","reference":"PN-EN 54-22:2015-07 (EN 54-22:2015) | PN-EN 54-22+A1:2020-07 (EN 54- 22:2015+A1:2020) w tym / including: | p. 5.6.1.1, 5.6.1.2 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.6.1.3, 5.6.1.4 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.6.2.1, 5.6.2.4 z wykorzystaniem / using PN-EN 60068-2-78:2007 p. 5.6.2.2, 5.6.2.3, 5.6.2.5 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.6.3.1 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.6.3.2 z wykorzystaniem / using PN-EN 60068-2-75:2000 p. 5.6.3.4, 5.6.3.5, 5.6.3.6, 5.6.3.7 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p. 5.6.4.1, 5.6.4.2, z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.6.5.1, 5.6.4.2, z wykorzystaniem / using PN-EN 50130-4:2012+A1:2015-03","norm_bases":["PN-EN 54-22:2015-07 (EN 54-22:2015)","PN-EN 54-22+A1:2020-07 (EN 54- 22:2015+A1:2020) w tym / including:","p. 5.6.1.1, 5.6.1.2 z wykorzystaniem / using PN-EN 60068-2-2:2009","p. 5.6.1.3, 5.6.1.4 z wykorzystaniem / using PN-EN 60068-2-1:2009","p. 5.6.2.1, 5.6.2.4 z wykorzystaniem / using PN-EN 60068-2-78:2007 p. 5.6.2.2, 5.6.2.3, 5.6.2.5 z wykorzystaniem / using PN-EN 60068-2-30:2008","p. 5.6.3.1 z wykorzystaniem / using PN-EN 60068-2-27:2009","p. 5.6.3.2 z wykorzystaniem / using PN-EN 60068-2-75:2000 p. 5.6.3.4, 5.6.3.5, 5.6.3.6, 5.6.3.7 z wykorzystaniem / using PN-EN 60068-2-6:2008","p. 5.6.4.1, 5.6.4.2, z wykorzystaniem / using PN-EN 60068-2-42:2004","p. 5.6.5.1, 5.6.4.2, z wykorzystaniem / using PN-EN 50130-4:2012+A1:2015-03"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Liniowa kasowalna czujka ciepła / Resettable line-type heat detector Cechy i właściwości do oceny funkcjonalności kasowalnej czujki ciepła według p. 4.1, 5, 7, 8 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the resettable line-type heat detector according to p. 4.1, 5, 7, 8 and ZA.1 table of the standard PN-EN 54-22:2015-07 (EN 54-22:2015) | PN-EN 54-22+A1:2020-07 (EN 54- 22:2015+A1:2020) w tym / including: | p. 5.6.1.1, 5.6.1.2 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.6.1.3, 5.6.1.4 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.6.2.1, 5.6.2.4 z wykorzystaniem / using PN-EN 60068-2-78:2007 p. 5.6.2.2, 5.6.2.3, 5.6.2.5 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.6.3.1 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.6.3.2 z wykorzystaniem / using PN-EN 60068-2-75:2000 p. 5.6.3.4, 5.6.3.5, 5.6.3.6, 5.6.3.7 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p. 5.6.4.1, 5.6.4.2, z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.6.5.1, 5.6.4.2, z wykorzystaniem / using PN-EN 50130-4:2012+A1:2015-03 Liniowa kasowalna czujka ciepla / Resettable line-type heat detector Cechy i wlasciwosci do oceny funkcjonalnosci kasowalnej czujki ciepla wedlug p. 4.1, 5, 7, 8 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the resettable line-type heat detector according to p. 4.1, 5, 7, 8 and ZA.1 table of the standard PN-EN 54-22:2015-07 (EN 54-22:2015) | PN-EN 54-22+A1:2020-07 (EN 54- 22:2015+A1:2020) w tym / including: | p. 5.6.1.1, 5.6.1.2 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.6.1.3, 5.6.1.4 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.6.2.1, 5.6.2.4 z wykorzystaniem / using PN-EN 60068-2-78:2007 p. 5.6.2.2, 5.6.2.3, 5.6.2.5 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.6.3.1 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.6.3.2 z wykorzystaniem / using PN-EN 60068-2-75:2000 p. 5.6.3.4, 5.6.3.5, 5.6.3.6, 5.6.3.7 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p. 5.6.4.1, 5.6.4.2, z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.6.5.1, 5.6.4.2, z wykorzystaniem / using PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbd9","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Sygnalizator optyczny / Visual alarm device","methodology":"Cechy i właściwości do oceny funkcjonalności sygnalizatora optycznego według Tablicy ZA.1 normy / Characteristics to functional assessment of the visual alarm device according to ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości do oceny funkcjonalności sygnalizatora optycznego według Tablicy ZA.1 normy / Characteristics to functional assessment of the visual alarm device according to ZA.1 table of the standard","reference":"PN-EN 54-23:2010 (EN 54-23:2010) w tym / including: | p. 4.2.4, 5.2.4 z wykorzystaniem / using PN-EN 60529:2003 | p. 5.4.1.1, 5.4.1.2 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.4.1.3 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.4.2.1, 5.4.2.3 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.4.2.2 z wykorzystaniem / using PN-EN 60068-2-78:2013 | p. 5.4.3.1 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.4.3.2 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p. 5.4.3.3, 5.4.3.4 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p. 5.4.4 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.4.5 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03","norm_bases":["PN-EN 54-23:2010 (EN 54-23:2010) w tym / including:","p. 4.2.4, 5.2.4 z wykorzystaniem / using PN-EN 60529:2003","p. 5.4.1.1, 5.4.1.2 z wykorzystaniem / using PN-EN 60068-2-2:2009","p. 5.4.1.3 z wykorzystaniem / using PN-EN 60068-2-1:2009","p. 5.4.2.1, 5.4.2.3 z wykorzystaniem / using PN-EN 60068-2-30:2008","p. 5.4.2.2 z wykorzystaniem / using PN-EN 60068-2-78:2013","p. 5.4.3.1 z wykorzystaniem / using PN-EN 60068-2-27:2009","p. 5.4.3.2 z wykorzystaniem / using PN-EN 60068-2-75:2000","p. 5.4.3.3, 5.4.3.4 z wykorzystaniem / using PN-EN 60068-2-6:2008","p. 5.4.4 z wykorzystaniem / using PN-EN 60068-2-42:2004","p. 5.4.5 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007","PN-EN 50130-4:2012+A1:2015-03"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sygnalizator optyczny / Visual alarm device Cechy i właściwości do oceny funkcjonalności sygnalizatora optycznego według Tablicy ZA.1 normy / Characteristics to functional assessment of the visual alarm device according to ZA.1 table of the standard PN-EN 54-23:2010 (EN 54-23:2010) w tym / including: | p. 4.2.4, 5.2.4 z wykorzystaniem / using PN-EN 60529:2003 | p. 5.4.1.1, 5.4.1.2 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.4.1.3 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.4.2.1, 5.4.2.3 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.4.2.2 z wykorzystaniem / using PN-EN 60068-2-78:2013 | p. 5.4.3.1 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.4.3.2 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p. 5.4.3.3, 5.4.3.4 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p. 5.4.4 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.4.5 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 Sygnalizator optyczny / Visual alarm device Cechy i wlasciwosci do oceny funkcjonalnosci sygnalizatora optycznego wedlug Tablicy ZA.1 normy / Characteristics to functional assessment of the visual alarm device according to ZA.1 table of the standard PN-EN 54-23:2010 (EN 54-23:2010) w tym / including: | p. 4.2.4, 5.2.4 z wykorzystaniem / using PN-EN 60529:2003 | p. 5.4.1.1, 5.4.1.2 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.4.1.3 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.4.2.1, 5.4.2.3 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.4.2.2 z wykorzystaniem / using PN-EN 60068-2-78:2013 | p. 5.4.3.1 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.4.3.2 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p. 5.4.3.3, 5.4.3.4 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p. 5.4.4 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.4.5 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbda","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Głośnik do dźwiękowego systemu ostrzegawczego / Loudspeaker of voice alarm system","methodology":"Cechy i parametry funkcjonalne głośników do dźwiękowych systemów ostrzegawczych, Poziom ciśnienia akustycznego, Pomiar w pasmach 1/3 oktawy, Characteristics and functional parameters of the loudspeakers, Sound pressure level, Measurement in 1/3 octave bands","parameters":[{"name":"Zakres","range":"(24 - 135) dB"},{"name":"Range","range":"(24 - 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia / Method: direct","techniques":["Metoda pomiarowa bezpośrednia /","Method: direct"],"computed":[],"activity":"Cechy i parametry funkcjonalne głośników do dźwiękowych systemów ostrzegawczych, Poziom ciśnienia akustycznego, Pomiar w pasmach 1/3 oktawy, Characteristics and functional parameters of the loudspeakers, Sound pressure level, Measurement in 1/3 octave bands\nZakres:\nZakres (24 - 135) dB\nRange (24 - 135) dB\nMetoda pomiarowa bezpośrednia / Method: direct","reference":"PN-EN 54-24:2008 (EN 54-24:2008) | ISO 7240-24:2010 | ISO 7240-24:2016","norm_bases":["PN-EN 54-24:2008 (EN 54-24:2008)","ISO 7240-24:2010","ISO 7240-24:2016"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Głośnik do dźwiękowego systemu ostrzegawczego / Loudspeaker of voice alarm system Cechy i parametry funkcjonalne głośników do dźwiękowych systemów ostrzegawczych, Poziom ciśnienia akustycznego, Pomiar w pasmach 1/3 oktawy, Characteristics and functional parameters of the loudspeakers, Sound pressure level, Measurement in 1/3 octave bands\nZakres:\nZakres (24 - 135) dB\nRange (24 - 135) dB\nMetoda pomiarowa bezpośrednia / Method: direct PN-EN 54-24:2008 (EN 54-24:2008) | ISO 7240-24:2010 | ISO 7240-24:2016 Glosnik do dzwiekowego systemu ostrzegawczego / Loudspeaker of voice alarm system Cechy i parametry funkcjonalne glosnikow do dzwiekowych systemow ostrzegawczych, Poziom cisnienia akustycznego, Pomiar w pasmach 1/3 oktawy, Characteristics and functional parameters of the loudspeakers, Sound pressure level, Measurement in 1/3 octave bands\nZakres:\nZakres (24 - 135) dB\nRange (24 - 135) dB\nMetoda pomiarowa bezposrednia / Method: direct PN-EN 54-24:2008 (EN 54-24:2008) | ISO 7240-24:2010 | ISO 7240-24:2016","categories":["other"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(24 - 135) dB"},{"name":"Range","range":"(24 - 135) dB"}],"search_en":"Range Range PN-EN 54-24:2008 (EN 54-24:2008) | ISO 7240-24:2010 | ISO 7240-24:2016","parameters_zh":[{"name":"范围","range":"(24 - 135) dB"},{"name":"范围","range":"(24 - 135) dB"}],"search_zh":"范围 范围 PN-EN 54-24:2008 (EN 54-24:2008) | ISO 7240-24:2010 | ISO 7240-24:2016"},{"_id":"6a8369aeaf14b9c0e7b1dbdb","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Podzespoły systemów sygnalizacji pożarowej wykorzystujące łącza radiowe / Components of fire detection and fire alarm systems using radio links","methodology":"Cechy i właściwości do oceny funkcjonalności podzespołu systemów sygnalizacji pożarowej wykorzystujących łącza radiowe według p. 8.3.8 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the components of fire detection and fire alarm systems using radio links according to p. 8.3.8 and ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości do oceny funkcjonalności podzespołu systemów sygnalizacji pożarowej wykorzystujących łącza radiowe według p. 8.3.8 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the components of fire detection and fire alarm systems using radio links according to p. 8.3.8 and ZA.1 table of the standard","reference":"PN-EN 54-25:2011+AC:2012 (EN 54-25:2008+AC:2010+AC:2012) w tym / including: | p. 4.2.5.3, 8.2.5 z wykorzystaniem / using EN 300220-1:2000 | EN 300220-1:2002 | EN 300220-1:2013 | p. 8.3.9, 8.3.10 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 8.3.11 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 8.3.12 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 8.3.13, 8.3.14 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 8.3.15 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 8.3.16 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 8.3.17 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p. 8.3.18, 8.3.19 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 8.3.20 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | ISO 7240-25:2010","norm_bases":["PN-EN 54-25:2011+AC:2012 (EN 54-25:2008+AC:2010+AC:2012) w tym / including:","p. 4.2.5.3, 8.2.5 z wykorzystaniem / using EN 300220-1:2000","EN 300220-1:2002","EN 300220-1:2013","p. 8.3.9, 8.3.10 z wykorzystaniem / using PN-EN 60068-2-2:2009","p. 8.3.11 z wykorzystaniem / using PN-EN 60068-2-1:2009","p. 8.3.12 z wykorzystaniem / using PN-EN 60068-2-30:2008","p. 8.3.13, 8.3.14 z wykorzystaniem / using PN-EN 60068-2-78:2007","p. 8.3.15 z wykorzystaniem / using PN-EN 60068-2-42:2004","p. 8.3.16 z wykorzystaniem / using PN-EN 60068-2-27:2009","p. 8.3.17 z wykorzystaniem / using PN-EN 60068-2-75:2000","p. 8.3.18, 8.3.19 z wykorzystaniem / using PN-EN 60068-2-6:2002","PN-EN 60068-2-6:2008","p. 8.3.20 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007","PN-EN 50130-4:2012+A1:2015-03","ISO 7240-25:2010"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Podzespoły systemów sygnalizacji pożarowej wykorzystujące łącza radiowe / Components of fire detection and fire alarm systems using radio links Cechy i właściwości do oceny funkcjonalności podzespołu systemów sygnalizacji pożarowej wykorzystujących łącza radiowe według p. 8.3.8 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the components of fire detection and fire alarm systems using radio links according to p. 8.3.8 and ZA.1 table of the standard PN-EN 54-25:2011+AC:2012 (EN 54-25:2008+AC:2010+AC:2012) w tym / including: | p. 4.2.5.3, 8.2.5 z wykorzystaniem / using EN 300220-1:2000 | EN 300220-1:2002 | EN 300220-1:2013 | p. 8.3.9, 8.3.10 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 8.3.11 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 8.3.12 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 8.3.13, 8.3.14 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 8.3.15 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 8.3.16 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 8.3.17 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p. 8.3.18, 8.3.19 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 8.3.20 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | ISO 7240-25:2010 Podzespoly systemow sygnalizacji pozarowej wykorzystujace lacza radiowe / Components of fire detection and fire alarm systems using radio links Cechy i wlasciwosci do oceny funkcjonalnosci podzespolu systemow sygnalizacji pozarowej wykorzystujacych lacza radiowe wedlug p. 8.3.8 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the components of fire detection and fire alarm systems using radio links according to p. 8.3.8 and ZA.1 table of the standard PN-EN 54-25:2011+AC:2012 (EN 54-25:2008+AC:2010+AC:2012) w tym / including: | p. 4.2.5.3, 8.2.5 z wykorzystaniem / using EN 300220-1:2000 | EN 300220-1:2002 | EN 300220-1:2013 | p. 8.3.9, 8.3.10 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 8.3.11 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 8.3.12 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 8.3.13, 8.3.14 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 8.3.15 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 8.3.16 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 8.3.17 z wykorzystaniem / using PN-EN 60068-2-75:2000 | p. 8.3.18, 8.3.19 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 8.3.20 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | ISO 7240-25:2010","categories":["other"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbdc","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Czujka tlenku węgla / Point carbon monoxide detector","methodology":"Cechy do oceny funkcjonalności czujki według p. 5.1 oraz Tabeli ZA.1 normy / Characteristics to functional assessment of the point carbon monoxide detector according to p. 5.1 and ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności czujki według p. 5.1 oraz Tabeli ZA.1 normy / Characteristics to functional assessment of the point carbon monoxide detector according to p. 5.1 and ZA.1 table of the standard","reference":"PN-EN 54-26:2015-05 (EN 54-26:2015) w tym / including: | 5.6.1.2 z wykorzystaniem / using: PN-EN 60068-2-2:2009 | 5.6.1.3 z wykorzystaniem / using: PN-EN 60068-2-1:2009 | 5.6.2.1 z wykorzystaniem / using: PN-EN 60068-2-30:2008 | 5.6.2.2 z wykorzystaniem / using: PN-EN 60068-2-78:2013 | 5.6.2.3 z wykorzystaniem / using: PN-EN 60068-2-78:2013 | 5.6.3 z wykorzystaniem / using: PN-EN 60068-2-42:2004 | 5.6.4.1 z wykorzystaniem / using: PN-EN 60068-2-27:2009 | 5.6.4.3 z wykorzystaniem / using: PN-EN 60068-2-6:2008 | 5.6.4.4 z wykorzystaniem / using: PN-EN 60068-2-6:2008 | 5.6.5 z wykorzystaniem / using: PN-EN 50130-4:2012+A1:2015","norm_bases":["PN-EN 54-26:2015-05 (EN 54-26:2015) w tym / including:","5.6.1.2 z wykorzystaniem / using: PN-EN 60068-2-2:2009","5.6.1.3 z wykorzystaniem / using: PN-EN 60068-2-1:2009","5.6.2.1 z wykorzystaniem / using: PN-EN 60068-2-30:2008","5.6.2.2 z wykorzystaniem / using: PN-EN 60068-2-78:2013","5.6.2.3 z wykorzystaniem / using: PN-EN 60068-2-78:2013","5.6.3 z wykorzystaniem / using: PN-EN 60068-2-42:2004","5.6.4.1 z wykorzystaniem / using: PN-EN 60068-2-27:2009","5.6.4.3 z wykorzystaniem / using: PN-EN 60068-2-6:2008","5.6.4.4 z wykorzystaniem / using: PN-EN 60068-2-6:2008","5.6.5 z wykorzystaniem / using: PN-EN 50130-4:2012+A1:2015"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Czujka tlenku węgla / Point carbon monoxide detector Cechy do oceny funkcjonalności czujki według p. 5.1 oraz Tabeli ZA.1 normy / Characteristics to functional assessment of the point carbon monoxide detector according to p. 5.1 and ZA.1 table of the standard PN-EN 54-26:2015-05 (EN 54-26:2015) w tym / including: | 5.6.1.2 z wykorzystaniem / using: PN-EN 60068-2-2:2009 | 5.6.1.3 z wykorzystaniem / using: PN-EN 60068-2-1:2009 | 5.6.2.1 z wykorzystaniem / using: PN-EN 60068-2-30:2008 | 5.6.2.2 z wykorzystaniem / using: PN-EN 60068-2-78:2013 | 5.6.2.3 z wykorzystaniem / using: PN-EN 60068-2-78:2013 | 5.6.3 z wykorzystaniem / using: PN-EN 60068-2-42:2004 | 5.6.4.1 z wykorzystaniem / using: PN-EN 60068-2-27:2009 | 5.6.4.3 z wykorzystaniem / using: PN-EN 60068-2-6:2008 | 5.6.4.4 z wykorzystaniem / using: PN-EN 60068-2-6:2008 | 5.6.5 z wykorzystaniem / using: PN-EN 50130-4:2012+A1:2015 Czujka tlenku wegla / Point carbon monoxide detector Cechy do oceny funkcjonalnosci czujki wedlug p. 5.1 oraz Tabeli ZA.1 normy / Characteristics to functional assessment of the point carbon monoxide detector according to p. 5.1 and ZA.1 table of the standard PN-EN 54-26:2015-05 (EN 54-26:2015) w tym / including: | 5.6.1.2 z wykorzystaniem / using: PN-EN 60068-2-2:2009 | 5.6.1.3 z wykorzystaniem / using: PN-EN 60068-2-1:2009 | 5.6.2.1 z wykorzystaniem / using: PN-EN 60068-2-30:2008 | 5.6.2.2 z wykorzystaniem / using: PN-EN 60068-2-78:2013 | 5.6.2.3 z wykorzystaniem / using: PN-EN 60068-2-78:2013 | 5.6.3 z wykorzystaniem / using: PN-EN 60068-2-42:2004 | 5.6.4.1 z wykorzystaniem / using: PN-EN 60068-2-27:2009 | 5.6.4.3 z wykorzystaniem / using: PN-EN 60068-2-6:2008 | 5.6.4.4 z wykorzystaniem / using: PN-EN 60068-2-6:2008 | 5.6.5 z wykorzystaniem / using: PN-EN 50130-4:2012+A1:2015","categories":["other"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbdd","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Kanałowa czujka dymu, Osłona przeciwwietrzna / Duct smoke detector","methodology":"Cechy i właściwości do oceny funkcjonalności kanałowej czujki dymu (osłony przeciwwietrznej) według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the duct smoke detector according to p. 5.1 and ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości do oceny funkcjonalności kanałowej czujki dymu (osłony przeciwwietrznej) według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the duct smoke detector according to p. 5.1 and ZA.1 table of the standard","reference":"PN-EN 54-27:2015-04 (EN 54-27:2015) w tym / including: | p. 5.6.1.1 z wykorzystaniem / using PN-EN 60068-2-2:2009 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | p. 5.6.1.2 z wykorzystaniem / using PN-EN 60068-2-1:2009 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | p. 5.6.2.1, 5.6.2.2 z wykorzystaniem / using PN-EN 60068-2-78:2013 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | p. 5.6.3 z wykorzystaniem / using PN-EN 60068-2-42:2004 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | p. 5.6.4.1 z wykorzystaniem / using PN-EN 60068-2-27:2009 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | p. 5.6.4.2 z wykorzystaniem / using PN-EN 60068-2-75:2000 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | p. 5.6.4.3, 5.6.4.4 z wykorzystaniem / using PN-EN 60068-2-6:2008 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | p. 5.6.5 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | ISO/TS 7240-9:2012","norm_bases":["PN-EN 54-27:2015-04 (EN 54-27:2015) w tym / including:","p. 5.6.1.1 z wykorzystaniem / using PN-EN 60068-2-2:2009","PB/BA/36, edycja / edition 6 z / of 11.12.2012","p. 5.6.1.2 z wykorzystaniem / using PN-EN 60068-2-1:2009","PB/BA/36, edycja / edition 6 z / of 11.12.2012","p. 5.6.2.1, 5.6.2.2 z wykorzystaniem / using PN-EN 60068-2-78:2013","PB/BA/36, edycja / edition 6 z / of 11.12.2012","p. 5.6.3 z wykorzystaniem / using PN-EN 60068-2-42:2004","PB/BA/36, edycja / edition 6 z / of 11.12.2012","p. 5.6.4.1 z wykorzystaniem / using PN-EN 60068-2-27:2009","PB/BA/36, edycja / edition 6 z / of 11.12.2012","p. 5.6.4.2 z wykorzystaniem / using PN-EN 60068-2-75:2000","PB/BA/36, edycja / edition 6 z / of 11.12.2012","p. 5.6.4.3, 5.6.4.4 z wykorzystaniem / using PN-EN 60068-2-6:2008","PB/BA/36, edycja / edition 6 z / of 11.12.2012","p. 5.6.5 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007","PN-EN 50130-4:2012+A1:2015-03","PB/BA/36, edycja / edition 6 z / of 11.12.2012","ISO/TS 7240-9:2012"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kanałowa czujka dymu, Osłona przeciwwietrzna / Duct smoke detector Cechy i właściwości do oceny funkcjonalności kanałowej czujki dymu (osłony przeciwwietrznej) według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the duct smoke detector according to p. 5.1 and ZA.1 table of the standard PN-EN 54-27:2015-04 (EN 54-27:2015) w tym / including: | p. 5.6.1.1 z wykorzystaniem / using PN-EN 60068-2-2:2009 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | p. 5.6.1.2 z wykorzystaniem / using PN-EN 60068-2-1:2009 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | p. 5.6.2.1, 5.6.2.2 z wykorzystaniem / using PN-EN 60068-2-78:2013 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | p. 5.6.3 z wykorzystaniem / using PN-EN 60068-2-42:2004 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | p. 5.6.4.1 z wykorzystaniem / using PN-EN 60068-2-27:2009 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | p. 5.6.4.2 z wykorzystaniem / using PN-EN 60068-2-75:2000 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | p. 5.6.4.3, 5.6.4.4 z wykorzystaniem / using PN-EN 60068-2-6:2008 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | p. 5.6.5 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | ISO/TS 7240-9:2012 Kanalowa czujka dymu, Oslona przeciwwietrzna / Duct smoke detector Cechy i wlasciwosci do oceny funkcjonalnosci kanalowej czujki dymu (oslony przeciwwietrznej) wedlug p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the duct smoke detector according to p. 5.1 and ZA.1 table of the standard PN-EN 54-27:2015-04 (EN 54-27:2015) w tym / including: | p. 5.6.1.1 z wykorzystaniem / using PN-EN 60068-2-2:2009 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | p. 5.6.1.2 z wykorzystaniem / using PN-EN 60068-2-1:2009 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | p. 5.6.2.1, 5.6.2.2 z wykorzystaniem / using PN-EN 60068-2-78:2013 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | p. 5.6.3 z wykorzystaniem / using PN-EN 60068-2-42:2004 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | p. 5.6.4.1 z wykorzystaniem / using PN-EN 60068-2-27:2009 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | p. 5.6.4.2 z wykorzystaniem / using PN-EN 60068-2-75:2000 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | p. 5.6.4.3, 5.6.4.4 z wykorzystaniem / using PN-EN 60068-2-6:2008 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | p. 5.6.5 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | PB/BA/36, edycja / edition 6 z / of 11.12.2012 | ISO/TS 7240-9:2012","categories":["other"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbde","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Czujka ciepła liniowa niekasowalna / Non-resettable line-type heat detector","methodology":"Cechy i właściwości do oceny funkcjonalności czujki ciepła liniowej niekasowalnej według p. 5 oraz Tablicy ZA.1 normy, Pomiar temperatury, Characteristics to functional assessment of the non-resettable line-type heat detector according to p. 5.1 and ZA.1 table of the standard, Temperature measurement","parameters":[{"name":"Zakres","range":"(0- 148) °C"},{"name":"Range","range":"(0- 148) °C"}],"technique":"Metoda: bezpośrednia / Method: direct","techniques":["Metoda: bezpośrednia /","Method: direct"],"computed":[],"activity":"Cechy i właściwości do oceny funkcjonalności czujki ciepła liniowej niekasowalnej według p. 5 oraz Tablicy ZA.1 normy, Pomiar temperatury, Characteristics to functional assessment of the non-resettable line-type heat detector according to p. 5.1 and ZA.1 table of the standard, Temperature measurement\nZakres:\nZakres (0- 148) °C\nRange (0- 148) °C\nMetoda: bezpośrednia / Method: direct","reference":"PN-EN 54-28:2016-06 | EN 54-28:2016","norm_bases":["PN-EN 54-28:2016-06","EN 54-28:2016"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Czujka ciepła liniowa niekasowalna / Non-resettable line-type heat detector Cechy i właściwości do oceny funkcjonalności czujki ciepła liniowej niekasowalnej według p. 5 oraz Tablicy ZA.1 normy, Pomiar temperatury, Characteristics to functional assessment of the non-resettable line-type heat detector according to p. 5.1 and ZA.1 table of the standard, Temperature measurement\nZakres:\nZakres (0- 148) °C\nRange (0- 148) °C\nMetoda: bezpośrednia / Method: direct PN-EN 54-28:2016-06 | EN 54-28:2016 Czujka ciepla liniowa niekasowalna / Non-resettable line-type heat detector Cechy i wlasciwosci do oceny funkcjonalnosci czujki ciepla liniowej niekasowalnej wedlug p. 5 oraz Tablicy ZA.1 normy, Pomiar temperatury, Characteristics to functional assessment of the non-resettable line-type heat detector according to p. 5.1 and ZA.1 table of the standard, Temperature measurement\nZakres:\nZakres (0- 148) °C\nRange (0- 148) °C\nMetoda: bezposrednia / Method: direct PN-EN 54-28:2016-06 | EN 54-28:2016","categories":["other"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0- 148) °C"},{"name":"Range","range":"(0- 148) °C"}],"search_en":"Range Range PN-EN 54-28:2016-06 | EN 54-28:2016","parameters_zh":[{"name":"范围","range":"(0- 148) °C"},{"name":"范围","range":"(0- 148) °C"}],"search_zh":"范围 范围 PN-EN 54-28:2016-06 | EN 54-28:2016"},{"_id":"6a8369aeaf14b9c0e7b1dbdf","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Czujka wielodetektorowa / Multi-sensor fire detector","methodology":"Cechy do oceny funkcjonalności czujki wielodetektorowej według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the multi-sensor fire detector according to p. 5.1 and ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności czujki wielodetektorowej według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the multi-sensor fire detector according to p. 5.1 and ZA.1 table of the standard","reference":"PN-EN 54-5:2003 (EN 54-5:2003+A1:2002) w tym / including: | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.10. z wykorzystaniem / using PN-EN 60068-2-2:2002 | PN-EN 60068-2-2:2009 | p. 5.11 z wykorzystaniem / using PN–EN 60068-2-30:2008 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.13. z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.14 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.16 i 5.17 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.18 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | ISO 7240-15:2014","norm_bases":["PN-EN 54-5:2003 (EN 54-5:2003+A1:2002) w tym / including:","p. 5.9 z wykorzystaniem / using PN-EN 60068-2-1:2009","p. 5.10. z wykorzystaniem / using PN-EN 60068-2-2:2002","PN-EN 60068-2-2:2009","p. 5.11 z wykorzystaniem / using PN–EN 60068-2-30:2008","p. 5.12 z wykorzystaniem / using PN-EN 60068-2-78:2007","p. 5.13. z wykorzystaniem / using PN-EN 60068-2-42:2004","p. 5.14 z wykorzystaniem / using PN-EN 60068-2-27:2009","p. 5.16 i 5.17 z wykorzystaniem / using PN-EN 60068-2-6:2002","PN-EN 60068-2-6:2008","p. 5.18 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007","PN-EN 50130-4:2012+A1:2015-03","ISO 7240-15:2014"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Czujka wielodetektorowa / Multi-sensor fire detector Cechy do oceny funkcjonalności czujki wielodetektorowej według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the multi-sensor fire detector according to p. 5.1 and ZA.1 table of the standard PN-EN 54-5:2003 (EN 54-5:2003+A1:2002) w tym / including: | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.10. z wykorzystaniem / using PN-EN 60068-2-2:2002 | PN-EN 60068-2-2:2009 | p. 5.11 z wykorzystaniem / using PN–EN 60068-2-30:2008 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.13. z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.14 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.16 i 5.17 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.18 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | ISO 7240-15:2014 Czujka wielodetektorowa / Multi-sensor fire detector Cechy do oceny funkcjonalnosci czujki wielodetektorowej wedlug p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the multi-sensor fire detector according to p. 5.1 and ZA.1 table of the standard PN-EN 54-5:2003 (EN 54-5:2003+A1:2002) w tym / including: | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.10. z wykorzystaniem / using PN-EN 60068-2-2:2002 | PN-EN 60068-2-2:2009 | p. 5.11 z wykorzystaniem / using PN–EN 60068-2-30:2008 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.13. z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.14 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.16 i 5.17 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.18 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | ISO 7240-15:2014","categories":["other"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbe0","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Czujka wielodetektorowa / Multi-sensor fire detector","methodology":"Cechy do oceny funkcjonalności czujki wielodetektorowej według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the multi-sensor fire detector according to p. 5.1 and ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności czujki wielodetektorowej według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the multi-sensor fire detector according to p. 5.1 and ZA.1 table of the standard","reference":"PN-EN 54-7:2004+A2:2009 (EN 54-7:2000+A2:2006) w tym / including: | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p.5.10 i 5.11 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.13 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.15, 5.16 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.17 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | ISO/TS 7240-9:2012 | ISO 7240-15:2014","norm_bases":["PN-EN 54-7:2004+A2:2009 (EN 54-7:2000+A2:2006) w tym / including:","p. 5.9 z wykorzystaniem / using PN-EN 60068-2-1:2009","p.5.10 i 5.11 z wykorzystaniem / using PN-EN 60068-2-78:2007","p. 5.12 z wykorzystaniem / using PN-EN 60068-2-42:2004","p. 5.13 z wykorzystaniem / using PN-EN 60068-2-27:2009","p. 5.15, 5.16 z wykorzystaniem / using PN-EN 60068-2-6:2002","PN-EN 60068-2-6:2008","p. 5.17 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007","PN-EN 50130-4:2012+A1:2015-03","ISO/TS 7240-9:2012","ISO 7240-15:2014"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Czujka wielodetektorowa / Multi-sensor fire detector Cechy do oceny funkcjonalności czujki wielodetektorowej według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the multi-sensor fire detector according to p. 5.1 and ZA.1 table of the standard PN-EN 54-7:2004+A2:2009 (EN 54-7:2000+A2:2006) w tym / including: | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p.5.10 i 5.11 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.13 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.15, 5.16 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.17 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | ISO/TS 7240-9:2012 | ISO 7240-15:2014 Czujka wielodetektorowa / Multi-sensor fire detector Cechy do oceny funkcjonalnosci czujki wielodetektorowej wedlug p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the multi-sensor fire detector according to p. 5.1 and ZA.1 table of the standard PN-EN 54-7:2004+A2:2009 (EN 54-7:2000+A2:2006) w tym / including: | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p.5.10 i 5.11 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.13 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.15, 5.16 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.17 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | ISO/TS 7240-9:2012 | ISO 7240-15:2014","categories":["other"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbe1","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Czujka wielodetektorowa / Multi-sensor fire detector","methodology":"Cechy do oceny funkcjonalności czujki wielodetektorowej według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the multi-sensor fire detector according to p. 5.1 and ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności czujki wielodetektorowej według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the multi-sensor fire detector according to p. 5.1 and ZA.1 table of the standard","reference":"PN-EN 54-10:2005+A1:2006 (EN 54-10:2002+A1:2005) w tym / including: | p. 5.7 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.8 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.10 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p.5.11 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.14, 5.15 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.17 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03","norm_bases":["PN-EN 54-10:2005+A1:2006 (EN 54-10:2002+A1:2005) w tym / including:","p. 5.7 z wykorzystaniem / using PN-EN 60068-2-2:2009","p. 5.8 z wykorzystaniem / using PN-EN 60068-2-1:2009","p. 5.9 z wykorzystaniem / using PN-EN 60068-2-30:2008","p. 5.10 z wykorzystaniem / using PN-EN 60068-2-78:2007","p.5.11 z wykorzystaniem / using PN-EN 60068-2-42:2004","p. 5.12 z wykorzystaniem / using PN-EN 60068-2-27:2009","p. 5.14, 5.15 z wykorzystaniem / using PN-EN 60068-2-6:2002","PN-EN 60068-2-6:2008","p. 5.17 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007","PN-EN 50130-4:2012+A1:2015-03"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Czujka wielodetektorowa / Multi-sensor fire detector Cechy do oceny funkcjonalności czujki wielodetektorowej według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the multi-sensor fire detector according to p. 5.1 and ZA.1 table of the standard PN-EN 54-10:2005+A1:2006 (EN 54-10:2002+A1:2005) w tym / including: | p. 5.7 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.8 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.10 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p.5.11 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.14, 5.15 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.17 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 Czujka wielodetektorowa / Multi-sensor fire detector Cechy do oceny funkcjonalnosci czujki wielodetektorowej wedlug p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the multi-sensor fire detector according to p. 5.1 and ZA.1 table of the standard PN-EN 54-10:2005+A1:2006 (EN 54-10:2002+A1:2005) w tym / including: | p. 5.7 z wykorzystaniem / using PN-EN 60068-2-2:2009 | p. 5.8 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.9 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.10 z wykorzystaniem / using PN-EN 60068-2-78:2007 | p.5.11 z wykorzystaniem / using PN-EN 60068-2-42:2004 | p. 5.12 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.14, 5.15 z wykorzystaniem / using PN-EN 60068-2-6:2002 | PN-EN 60068-2-6:2008 | p. 5.17 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbe2","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Czujka wielodetektorowa / Multi-sensor fire detector","methodology":"Cechy do oceny funkcjonalności czujki wielodetektorowej według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the multi-sensor fire detector according to p. 5.1 and ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności czujki wielodetektorowej według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the multi-sensor fire detector according to p. 5.1 and ZA.1 table of the standard","reference":"PN-EN 54-29:2015-05 (EN 54-29:2015) w tym / including: | p. 5.2.6 z wykorzystaniem / using PN-EN 54-5:2003 | p. 5.6.1.2 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.6.2.1 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.6.2.2 z wykorzystaniem / using PN-EN 60068-2-78:2013 | p. 5.6.3.1 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.6.3.3, 5.6.3.4 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p. 5.6.4.1 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | p. 5.6.5.1 z wykorzystaniem / using PN-EN 60068-2-42:2004","norm_bases":["PN-EN 54-29:2015-05 (EN 54-29:2015) w tym / including:","p. 5.2.6 z wykorzystaniem / using PN-EN 54-5:2003","p. 5.6.1.2 z wykorzystaniem / using PN-EN 60068-2-1:2009","p. 5.6.2.1 z wykorzystaniem / using PN-EN 60068-2-30:2008","p. 5.6.2.2 z wykorzystaniem / using PN-EN 60068-2-78:2013","p. 5.6.3.1 z wykorzystaniem / using PN-EN 60068-2-27:2009","p. 5.6.3.3, 5.6.3.4 z wykorzystaniem / using PN-EN 60068-2-6:2008","p. 5.6.4.1 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007","PN-EN 50130-4:2012+A1:2015-03","p. 5.6.5.1 z wykorzystaniem / using PN-EN 60068-2-42:2004"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Czujka wielodetektorowa / Multi-sensor fire detector Cechy do oceny funkcjonalności czujki wielodetektorowej według p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the multi-sensor fire detector according to p. 5.1 and ZA.1 table of the standard PN-EN 54-29:2015-05 (EN 54-29:2015) w tym / including: | p. 5.2.6 z wykorzystaniem / using PN-EN 54-5:2003 | p. 5.6.1.2 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.6.2.1 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.6.2.2 z wykorzystaniem / using PN-EN 60068-2-78:2013 | p. 5.6.3.1 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.6.3.3, 5.6.3.4 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p. 5.6.4.1 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | p. 5.6.5.1 z wykorzystaniem / using PN-EN 60068-2-42:2004 Czujka wielodetektorowa / Multi-sensor fire detector Cechy do oceny funkcjonalnosci czujki wielodetektorowej wedlug p. 5.1 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the multi-sensor fire detector according to p. 5.1 and ZA.1 table of the standard PN-EN 54-29:2015-05 (EN 54-29:2015) w tym / including: | p. 5.2.6 z wykorzystaniem / using PN-EN 54-5:2003 | p. 5.6.1.2 z wykorzystaniem / using PN-EN 60068-2-1:2009 | p. 5.6.2.1 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 5.6.2.2 z wykorzystaniem / using PN-EN 60068-2-78:2013 | p. 5.6.3.1 z wykorzystaniem / using PN-EN 60068-2-27:2009 | p. 5.6.3.3, 5.6.3.4 z wykorzystaniem / using PN-EN 60068-2-6:2008 | p. 5.6.4.1 z wykorzystaniem / using PN-EN 50130-4:2002+A2:2007 | PN-EN 50130-4:2012+A1:2015-03 | p. 5.6.5.1 z wykorzystaniem / using PN-EN 60068-2-42:2004","categories":["other"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbe3","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Czujka pożarowa wielodetektorowe - Czujka punktowa wykorzystująca kombinację detektorów tlenku węgla i ciepła / Multi-sensor fire detector – Point detector using a combination of carbon monoxide and heat sensors","methodology":"Cechy i właściwości do oceny funkcjonalności czujki punktowej wykorzystującej kombinację detektorów tlenku węgla i ciepła według normy, Characteristics to functional assessment of the point detector using a combination of carbon monoxide and heat sensors according to the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości do oceny funkcjonalności czujki punktowej wykorzystującej kombinację detektorów tlenku węgla i ciepła według normy, Characteristics to functional assessment of the point detector using a combination of carbon monoxide and heat sensors according to the standard","reference":"PN-EN 54-30:2015-05 (EN 54-30:2015)","norm_bases":["PN-EN 54-30:2015-05 (EN 54-30:2015)"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Czujka pożarowa wielodetektorowe - Czujka punktowa wykorzystująca kombinację detektorów tlenku węgla i ciepła / Multi-sensor fire detector – Point detector using a combination of carbon monoxide and heat sensors Cechy i właściwości do oceny funkcjonalności czujki punktowej wykorzystującej kombinację detektorów tlenku węgla i ciepła według normy, Characteristics to functional assessment of the point detector using a combination of carbon monoxide and heat sensors according to the standard PN-EN 54-30:2015-05 (EN 54-30:2015) Czujka pozarowa wielodetektorowe - Czujka punktowa wykorzystujaca kombinacje detektorow tlenku wegla i ciepla / Multi-sensor fire detector – Point detector using a combination of carbon monoxide and heat sensors Cechy i wlasciwosci do oceny funkcjonalnosci czujki punktowej wykorzystujacej kombinacje detektorow tlenku wegla i ciepla wedlug normy, Characteristics to functional assessment of the point detector using a combination of carbon monoxide and heat sensors according to the standard PN-EN 54-30:2015-05 (EN 54-30:2015)","categories":["other"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbe4","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Czujka pożarowa wielodetektorowa - Czujka punktowa wykorzystująca kombinację detektorów dymu, tlenku węgla i opcjonalnie ciepła / Multi-sensor fire detector – Point detector using a combination of smoke, carbon monoxide and optionally heat sensors","methodology":"Cechy i właściwości do oceny funkcjonalności czujki punktowej wykorzystującej kombinację detektorów dymu, tlenku węgla i opcjonalnie ciepła według normy, Characteristics to functional assessment of the point detector using a combination of smoke, carbon monoxide and optionally heat sensors according to the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości do oceny funkcjonalności czujki punktowej wykorzystującej kombinację detektorów dymu, tlenku węgla i opcjonalnie ciepła według normy, Characteristics to functional assessment of the point detector using a combination of smoke, carbon monoxide and optionally heat sensors according to the standard","reference":"PN-EN 54-31+A1:2016-06 (EN 54-31:2014+A1:2016)","norm_bases":["PN-EN 54-31+A1:2016-06 (EN 54-31:2014+A1:2016)"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Czujka pożarowa wielodetektorowa - Czujka punktowa wykorzystująca kombinację detektorów dymu, tlenku węgla i opcjonalnie ciepła / Multi-sensor fire detector – Point detector using a combination of smoke, carbon monoxide and optionally heat sensors Cechy i właściwości do oceny funkcjonalności czujki punktowej wykorzystującej kombinację detektorów dymu, tlenku węgla i opcjonalnie ciepła według normy, Characteristics to functional assessment of the point detector using a combination of smoke, carbon monoxide and optionally heat sensors according to the standard PN-EN 54-31+A1:2016-06 (EN 54-31:2014+A1:2016) Czujka pozarowa wielodetektorowa - Czujka punktowa wykorzystujaca kombinacje detektorow dymu, tlenku wegla i opcjonalnie ciepla / Multi-sensor fire detector – Point detector using a combination of smoke, carbon monoxide and optionally heat sensors Cechy i wlasciwosci do oceny funkcjonalnosci czujki punktowej wykorzystujacej kombinacje detektorow dymu, tlenku wegla i opcjonalnie ciepla wedlug normy, Characteristics to functional assessment of the point detector using a combination of smoke, carbon monoxide and optionally heat sensors according to the standard PN-EN 54-31+A1:2016-06 (EN 54-31:2014+A1:2016)","categories":["other"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbe5","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Centrala sterująca gaszeniem / Electrical automatic control and delay device","methodology":"Cechy do oceny funkcjonalności centrali sterującej gaszeniem według p. 7, 8 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the electrical automatic control and delay device according to p. 7, 8 and ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności centrali sterującej gaszeniem według p. 7, 8 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the electrical automatic control and delay device according to p. 7, 8 and ZA.1 table of the standard","reference":"PN-EN 12094-1:2006 (EN 12094-1:2003) w tym / including: | p. 5.2 z wykorzystaniem / using PN-EN 60529:2003 | p. 9.3 z wykorzystaniem / using PN-EN 54-2:2002+A1:2007 | p. 9.4 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 9.5 z wykorzystaniem / using PN-EN 60068-2-42:2004","norm_bases":["PN-EN 12094-1:2006 (EN 12094-1:2003) w tym / including:","p. 5.2 z wykorzystaniem / using PN-EN 60529:2003","p. 9.3 z wykorzystaniem / using PN-EN 54-2:2002+A1:2007","p. 9.4 z wykorzystaniem / using PN-EN 60068-2-30:2008","p. 9.5 z wykorzystaniem / using PN-EN 60068-2-42:2004"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Centrala sterująca gaszeniem / Electrical automatic control and delay device Cechy do oceny funkcjonalności centrali sterującej gaszeniem według p. 7, 8 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the electrical automatic control and delay device according to p. 7, 8 and ZA.1 table of the standard PN-EN 12094-1:2006 (EN 12094-1:2003) w tym / including: | p. 5.2 z wykorzystaniem / using PN-EN 60529:2003 | p. 9.3 z wykorzystaniem / using PN-EN 54-2:2002+A1:2007 | p. 9.4 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 9.5 z wykorzystaniem / using PN-EN 60068-2-42:2004 Centrala sterujaca gaszeniem / Electrical automatic control and delay device Cechy do oceny funkcjonalnosci centrali sterujacej gaszeniem wedlug p. 7, 8 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the electrical automatic control and delay device according to p. 7, 8 and ZA.1 table of the standard PN-EN 12094-1:2006 (EN 12094-1:2003) w tym / including: | p. 5.2 z wykorzystaniem / using PN-EN 60529:2003 | p. 9.3 z wykorzystaniem / using PN-EN 54-2:2002+A1:2007 | p. 9.4 z wykorzystaniem / using PN-EN 60068-2-30:2008 | p. 9.5 z wykorzystaniem / using PN-EN 60068-2-42:2004","categories":["other"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbe6","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Ręczne urządzenie inicjujące i wstrzymujące (elektryczne) / Electrical manual triggering and stop device","methodology":"Cechy do oceny funkcjonalności ręcznego urządzenia inicjującego i wstrzymującego według p. 4.3, 5.1, 5.3, 6 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the electrical manual triggering and stop device according to p. 4.3, 5.1, 5.3, 6and ZA.1 table of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności ręcznego urządzenia inicjującego i wstrzymującego według p. 4.3, 5.1, 5.3, 6 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the electrical manual triggering and stop device according to p. 4.3, 5.1, 5.3, 6and ZA.1 table of the standard","reference":"PN-EN 12094-3:2006 (EN 12094-3:2003) w tym / including: | p. 4.1, 5.1, z wykorzystaniem / using PN-EN 54-11:2004+A1:2006","norm_bases":["PN-EN 12094-3:2006 (EN 12094-3:2003) w tym / including:","p. 4.1, 5.1, z wykorzystaniem / using PN-EN 54-11:2004+A1:2006"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ręczne urządzenie inicjujące i wstrzymujące (elektryczne) / Electrical manual triggering and stop device Cechy do oceny funkcjonalności ręcznego urządzenia inicjującego i wstrzymującego według p. 4.3, 5.1, 5.3, 6 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the electrical manual triggering and stop device according to p. 4.3, 5.1, 5.3, 6and ZA.1 table of the standard PN-EN 12094-3:2006 (EN 12094-3:2003) w tym / including: | p. 4.1, 5.1, z wykorzystaniem / using PN-EN 54-11:2004+A1:2006 Reczne urzadzenie inicjujace i wstrzymujace (elektryczne) / Electrical manual triggering and stop device Cechy do oceny funkcjonalnosci recznego urzadzenia inicjujacego i wstrzymujacego wedlug p. 4.3, 5.1, 5.3, 6 oraz Tablicy ZA.1 normy / Characteristics to functional assessment of the electrical manual triggering and stop device according to p. 4.3, 5.1, 5.3, 6and ZA.1 table of the standard PN-EN 12094-3:2006 (EN 12094-3:2003) w tym / including: | p. 4.1, 5.1, z wykorzystaniem / using PN-EN 54-11:2004+A1:2006","categories":["other"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbe7","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Oprawa oświetleniowa / Luminaires, Oprawa oświetleniowa do oświetlenia awaryjnego / Luminaires for emergency lighting","methodology":"Cechy do oceny funkcjonalności oprawy oświetleniowej do oświetlenia awaryjnego według p. 22.4, 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.11, 22.12, 22.13, 22.14, 22.15, 22.16, 22.17, 22.18, 22.19, 22.20 normy / Characteristics to functional assessment of the luminaries according to p. 22.4, 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.11, 22.12, 22.13, 22.14, 22.15, 22.16, 22.17, 22.18, 22.19, 22.20 of the standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności oprawy oświetleniowej do oświetlenia awaryjnego według p. 22.4, 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.11, 22.12, 22.13, 22.14, 22.15, 22.16, 22.17, 22.18, 22.19, 22.20 normy / Characteristics to functional assessment of the luminaries according to p. 22.4, 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.11, 22.12, 22.13, 22.14, 22.15, 22.16, 22.17, 22.18, 22.19, 22.20 of the standard","reference":"PN-EN 60598-2-22:2004+A2:2010 (IEC 60598-2-22:1997+AMD2:2008 EN 60598-2-22:1998+A2:2008) w tym / including: p. 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.11, 22.12, 22.13, 22.14, 22.15, 22.16, 22.19, 22.20 z wykorzystaniem / using PN-EN 60598-1:2011 (EN 60598-1:2008+A11:2009 IEC 60598-1:2008)","norm_bases":["PN-EN 60598-2-22:2004+A2:2010 (IEC 60598-2-22:1997+AMD2:2008 EN 60598-2-22:1998+A2:2008) w tym / including: p. 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.11, 22.12, 22.13, 22.14, 22.15, 22.16, 22.19, 22.20 z wykorzystaniem / using PN-EN 60598-1:2011 (EN 60598-1:2008+A11:2009 IEC 60598-1:2008)"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oprawa oświetleniowa / Luminaires, Oprawa oświetleniowa do oświetlenia awaryjnego / Luminaires for emergency lighting Cechy do oceny funkcjonalności oprawy oświetleniowej do oświetlenia awaryjnego według p. 22.4, 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.11, 22.12, 22.13, 22.14, 22.15, 22.16, 22.17, 22.18, 22.19, 22.20 normy / Characteristics to functional assessment of the luminaries according to p. 22.4, 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.11, 22.12, 22.13, 22.14, 22.15, 22.16, 22.17, 22.18, 22.19, 22.20 of the standard PN-EN 60598-2-22:2004+A2:2010 (IEC 60598-2-22:1997+AMD2:2008 EN 60598-2-22:1998+A2:2008) w tym / including: p. 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.11, 22.12, 22.13, 22.14, 22.15, 22.16, 22.19, 22.20 z wykorzystaniem / using PN-EN 60598-1:2011 (EN 60598-1:2008+A11:2009 IEC 60598-1:2008) Oprawa oswietleniowa / Luminaires, Oprawa oswietleniowa do oswietlenia awaryjnego / Luminaires for emergency lighting Cechy do oceny funkcjonalnosci oprawy oswietleniowej do oswietlenia awaryjnego wedlug p. 22.4, 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.11, 22.12, 22.13, 22.14, 22.15, 22.16, 22.17, 22.18, 22.19, 22.20 normy / Characteristics to functional assessment of the luminaries according to p. 22.4, 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.11, 22.12, 22.13, 22.14, 22.15, 22.16, 22.17, 22.18, 22.19, 22.20 of the standard PN-EN 60598-2-22:2004+A2:2010 (IEC 60598-2-22:1997+AMD2:2008 EN 60598-2-22:1998+A2:2008) w tym / including: p. 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.11, 22.12, 22.13, 22.14, 22.15, 22.16, 22.19, 22.20 z wykorzystaniem / using PN-EN 60598-1:2011 (EN 60598-1:2008+A11:2009 IEC 60598-1:2008)","categories":["other"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbe8","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Centralne układy zasilania / Central power supply systems","methodology":"Cechy do oceny funkcjonalności urządzenia, Characteristics to functional assessment of the device","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności urządzenia, Characteristics to functional assessment of the device","reference":"PN-EN 50171:2007 p. 6.2, 6.6, 6.7, 6.11, 6.12 (EN 50171:2001+ corrigendum Aug. 2001 p. 6.2, 6.6, 6.7, 6.11, 6.12) | PN-EN 50171:2022-10 p. 6.3, 6.7, 6.8, 6.12, 6.13 (EN 50171:2021 p. 6.3, 6.7,6.8, 6.12, 6.13)","norm_bases":["PN-EN 50171:2007 p. 6.2, 6.6, 6.7, 6.11, 6.12 (EN 50171:2001+ corrigendum Aug. 2001 p. 6.2, 6.6, 6.7, 6.11, 6.12)","PN-EN 50171:2022-10 p. 6.3, 6.7, 6.8, 6.12, 6.13 (EN 50171:2021 p. 6.3, 6.7,6.8, 6.12, 6.13)"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Centralne układy zasilania / Central power supply systems Cechy do oceny funkcjonalności urządzenia, Characteristics to functional assessment of the device PN-EN 50171:2007 p. 6.2, 6.6, 6.7, 6.11, 6.12 (EN 50171:2001+ corrigendum Aug. 2001 p. 6.2, 6.6, 6.7, 6.11, 6.12) | PN-EN 50171:2022-10 p. 6.3, 6.7, 6.8, 6.12, 6.13 (EN 50171:2021 p. 6.3, 6.7,6.8, 6.12, 6.13) Centralne uklady zasilania / Central power supply systems Cechy do oceny funkcjonalnosci urzadzenia, Characteristics to functional assessment of the device PN-EN 50171:2007 p. 6.2, 6.6, 6.7, 6.11, 6.12 (EN 50171:2001+ corrigendum Aug. 2001 p. 6.2, 6.6, 6.7, 6.11, 6.12) | PN-EN 50171:2022-10 p. 6.3, 6.7, 6.8, 6.12, 6.13 (EN 50171:2021 p. 6.3, 6.7,6.8, 6.12, 6.13)","categories":["other"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbe9","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Oprawa oświetleniowa / Luminaires, Oprawa oświetleniowa do oświetlenia awaryjnego / Luminaires for emergency lighting","methodology":"Cechy do oceny funkcjonalności oprawy oświetleniowej do oświetlenia awaryjnego według p. 22.4, 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.11, 22.12, 22.13, 22.14, 22.15, 22.16, 22.17, 22.18, 22.19, 22.20, 22.21 normy, Characteristics to functional assessment of the luminaries according to p. 22.4, 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.11, 22.12, 22.13, 22.14, 22.15, 22.16, 22.17, 22.18, 22.19, 22.20, 22.21 of the standard","parameters":[{"name":"Zakres","range":"(0 - 50000) lm"},{"name":"Range","range":"(0 - 50000) lm"}],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności oprawy oświetleniowej do oświetlenia awaryjnego według p. 22.4, 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.11, 22.12, 22.13, 22.14, 22.15, 22.16, 22.17, 22.18, 22.19, 22.20, 22.21 normy, Characteristics to functional assessment of the luminaries according to p. 22.4, 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.11, 22.12, 22.13, 22.14, 22.15, 22.16, 22.17, 22.18, 22.19, 22.20, 22.21 of the standard\nZakres:\nZakres (0 - 50000) lm\nRange (0 - 50000) lm","reference":"PN-EN 60598-2-22:2015-01 +AC:2016- 11+AC:2016-07 +AC1:2015-10+A1:2020-08 (IEC 60598-2-22:2014+COR2:2016 +COR1:2015+AMD1:2017 EN 60598-2-22:2014+AC:2016-09 +AC:2016-05+AC:2015+A1:2020) | PN-EN IEC 60598-2-22:2022-11 (EN IEC 60598-2-22:2022 IEC 60598-2-22:2021) w tym / including: p. 22.4, 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.12, 22.13, 22.14, 22.15, 22.16 z wykorzystaniem / using PN-EN 60598-1:2015-04 +AC:2016-02+A1:2018-04 (IEC 60598-1:2014+COR2:2015 +AMD1:2017 EN 60598-1:2015 +AC:2016+A1:2018) | PN-EN IEC 60598-1:2021-07+A11:2022-12 (IEC 60598-1:2020 EN IEC 60598-1:2021+A1:2022) | PN-EN IEC 60598-1:2025-04 (IEC 60598-1:2024 EN IEC 60598-1:2024) | PN-EN IEC 60598-1:2025-04/A11:2025-08 (EN IEC 60598-1:2024/A11:2024)","norm_bases":["PN-EN 60598-2-22:2015-01 +AC:2016- 11+AC:2016-07 +AC1:2015-10+A1:2020-08 (IEC 60598-2-22:2014+COR2:2016 +COR1:2015+AMD1:2017 EN 60598-2-22:2014+AC:2016-09 +AC:2016-05+AC:2015+A1:2020)","PN-EN IEC 60598-2-22:2022-11 (EN IEC 60598-2-22:2022 IEC 60598-2-22:2021) w tym / including: p. 22.4, 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.12, 22.13, 22.14, 22.15, 22.16 z wykorzystaniem / using PN-EN 60598-1:2015-04 +AC:2016-02+A1:2018-04 (IEC 60598-1:2014+COR2:2015 +AMD1:2017 EN 60598-1:2015 +AC:2016+A1:2018)","PN-EN IEC 60598-1:2021-07+A11:2022-12 (IEC 60598-1:2020 EN IEC 60598-1:2021+A1:2022)","PN-EN IEC 60598-1:2025-04 (IEC 60598-1:2024 EN IEC 60598-1:2024)","PN-EN IEC 60598-1:2025-04/A11:2025-08 (EN IEC 60598-1:2024/A11:2024)"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Oprawa oświetleniowa / Luminaires, Oprawa oświetleniowa do oświetlenia awaryjnego / Luminaires for emergency lighting Cechy do oceny funkcjonalności oprawy oświetleniowej do oświetlenia awaryjnego według p. 22.4, 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.11, 22.12, 22.13, 22.14, 22.15, 22.16, 22.17, 22.18, 22.19, 22.20, 22.21 normy, Characteristics to functional assessment of the luminaries according to p. 22.4, 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.11, 22.12, 22.13, 22.14, 22.15, 22.16, 22.17, 22.18, 22.19, 22.20, 22.21 of the standard\nZakres:\nZakres (0 - 50000) lm\nRange (0 - 50000) lm PN-EN 60598-2-22:2015-01 +AC:2016- 11+AC:2016-07 +AC1:2015-10+A1:2020-08 (IEC 60598-2-22:2014+COR2:2016 +COR1:2015+AMD1:2017 EN 60598-2-22:2014+AC:2016-09 +AC:2016-05+AC:2015+A1:2020) | PN-EN IEC 60598-2-22:2022-11 (EN IEC 60598-2-22:2022 IEC 60598-2-22:2021) w tym / including: p. 22.4, 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.12, 22.13, 22.14, 22.15, 22.16 z wykorzystaniem / using PN-EN 60598-1:2015-04 +AC:2016-02+A1:2018-04 (IEC 60598-1:2014+COR2:2015 +AMD1:2017 EN 60598-1:2015 +AC:2016+A1:2018) | PN-EN IEC 60598-1:2021-07+A11:2022-12 (IEC 60598-1:2020 EN IEC 60598-1:2021+A1:2022) | PN-EN IEC 60598-1:2025-04 (IEC 60598-1:2024 EN IEC 60598-1:2024) | PN-EN IEC 60598-1:2025-04/A11:2025-08 (EN IEC 60598-1:2024/A11:2024) Oprawa oswietleniowa / Luminaires, Oprawa oswietleniowa do oswietlenia awaryjnego / Luminaires for emergency lighting Cechy do oceny funkcjonalnosci oprawy oswietleniowej do oswietlenia awaryjnego wedlug p. 22.4, 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.11, 22.12, 22.13, 22.14, 22.15, 22.16, 22.17, 22.18, 22.19, 22.20, 22.21 normy, Characteristics to functional assessment of the luminaries according to p. 22.4, 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.11, 22.12, 22.13, 22.14, 22.15, 22.16, 22.17, 22.18, 22.19, 22.20, 22.21 of the standard\nZakres:\nZakres (0 - 50000) lm\nRange (0 - 50000) lm PN-EN 60598-2-22:2015-01 +AC:2016- 11+AC:2016-07 +AC1:2015-10+A1:2020-08 (IEC 60598-2-22:2014+COR2:2016 +COR1:2015+AMD1:2017 EN 60598-2-22:2014+AC:2016-09 +AC:2016-05+AC:2015+A1:2020) | PN-EN IEC 60598-2-22:2022-11 (EN IEC 60598-2-22:2022 IEC 60598-2-22:2021) w tym / including: p. 22.4, 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.12, 22.13, 22.14, 22.15, 22.16 z wykorzystaniem / using PN-EN 60598-1:2015-04 +AC:2016-02+A1:2018-04 (IEC 60598-1:2014+COR2:2015 +AMD1:2017 EN 60598-1:2015 +AC:2016+A1:2018) | PN-EN IEC 60598-1:2021-07+A11:2022-12 (IEC 60598-1:2020 EN IEC 60598-1:2021+A1:2022) | PN-EN IEC 60598-1:2025-04 (IEC 60598-1:2024 EN IEC 60598-1:2024) | PN-EN IEC 60598-1:2025-04/A11:2025-08 (EN IEC 60598-1:2024/A11:2024)","categories":["other"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0 - 50000) lm"},{"name":"Range","range":"(0 - 50000) lm"}],"search_en":"Range Range PN-EN 60598-2-22:2015-01 +AC:2016- 11+AC:2016-07 +AC1:2015-10+A1:2020-08 (IEC 60598-2-22:2014+COR2:2016 +COR1:2015+AMD1:2017 EN 60598-2-22:2014+AC:2016-09 +AC:2016-05+AC:2015+A1:2020) | PN-EN IEC 60598-2-22:2022-11 (EN IEC 60598-2-22:2022 IEC 60598-2-22:2021) w tym / including: p. 22.4, 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.12, 22.13, 22.14, 22.15, 22.16 z wykorzystaniem / using PN-EN 60598-1:2015-04 +AC:2016-02+A1:2018-04 (IEC 60598-1:2014+COR2:2015 +AMD1:2017 EN 60598-1:2015 +AC:2016+A1:2018) | PN-EN IEC 60598-1:2021-07+A11:2022-12 (IEC 60598-1:2020 EN IEC 60598-1:2021+A1:2022) | PN-EN IEC 60598-1:2025-04 (IEC 60598-1:2024 EN IEC 60598-1:2024) | PN-EN IEC 60598-1:2025-04/A11:2025-08 (EN IEC 60598-1:2024/A11:2024)","parameters_zh":[{"name":"范围","range":"(0 - 50000) lm"},{"name":"范围","range":"(0 - 50000) lm"}],"search_zh":"范围 范围 PN-EN 60598-2-22:2015-01 +AC:2016- 11+AC:2016-07 +AC1:2015-10+A1:2020-08 (IEC 60598-2-22:2014+COR2:2016 +COR1:2015+AMD1:2017 EN 60598-2-22:2014+AC:2016-09 +AC:2016-05+AC:2015+A1:2020) | PN-EN IEC 60598-2-22:2022-11 (EN IEC 60598-2-22:2022 IEC 60598-2-22:2021) w tym / including: p. 22.4, 22.5, 22.6, 22.7, 22.8, 22.9, 22.10, 22.12, 22.13, 22.14, 22.15, 22.16 z wykorzystaniem / using PN-EN 60598-1:2015-04 +AC:2016-02+A1:2018-04 (IEC 60598-1:2014+COR2:2015 +AMD1:2017 EN 60598-1:2015 +AC:2016+A1:2018) | PN-EN IEC 60598-1:2021-07+A11:2022-12 (IEC 60598-1:2020 EN IEC 60598-1:2021+A1:2022) | PN-EN IEC 60598-1:2025-04 (IEC 60598-1:2024 EN IEC 60598-1:2024) | PN-EN IEC 60598-1:2025-04/A11:2025-08 (EN IEC 60598-1:2024/A11:2024)"},{"_id":"6a8369aeaf14b9c0e7b1dbea","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm / Electric cables rated voltage up to 18/30 kV, external diameter up to 100 mm","methodology":"Wymiary liniowe, Linear dimensions","parameters":[{"name":"grubość izolacji","range":"(0 - 50) mm"},{"name":"grubość powłok niemetalowych","range":"(0 - 50) mm"},{"name":"wymiary zewnętrzne","range":"(0 - 300) mm"},{"name":"Rezystancja żył","range":"(0 -1999) Ω"},{"name":"insulation thickness","range":"(0 - 50) mm"},{"name":"thickness of non-metallic sheath","range":"(0 - 50) mm"},{"name":"External dimensions","range":"(0 - 300) mm"},{"name":"Conductor resistance","range":"(0 - 1999) Ω"}],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary liniowe, Linear dimensions\nZakres:\ngrubość izolacji (0 - 50) mm\ngrubość powłok niemetalowych (0 - 50) mm\nwymiary zewnętrzne (0 - 300) mm\nRezystancja żył (0 -1999) Ω\ninsulation thickness (0 - 50) mm\nthickness of non-metallic sheath (0 - 50) mm\nExternal dimensions (0 - 300) mm\nConductor resistance (0 - 1999) Ω","reference":"PN-EN 60811-201:2012 (EN 60811-201:2012, IEC 60811-201:2012) | PN-EN 60811-201:2012/A1:2018-02 (EN 60811-201:2012/A1:2017, IEC 60811- 201:2012/AMD1:2017) | PN-EN 60811-201:2012/A2:2024-03 (EN 60811-201:2012/A2:2023, IEC 60811- 201:2012/AMD2:2023) | PN-EN 60811-202:2012 (EN 60811-202:2012, IEC 60811-202:2012) | PN-EN 60811-202:2012/A1:2018-02 (EN 60811-202:2012/A1:2017, IEC 60811- 202:2012/AMD1:2017) | PN-EN 60811-202:2012/A2:2024-03 (EN 60811-202:2012/A2:2023, IEC 60811- 202:2012/AMD2:2023) | PN-EN 60811-203:2012 (EN 60811-203:2012, IEC 60811-203:2012) | PN-EN 60811-100:2012 | PN-HD 605 S2:2008 (HD 605 S2:2008) pkt. 2.1.1, 2.1.2, 2.1.3 | PN-EN 50396:2007+A1:2011 (EN 50396:2005+A1:2011) pkt 4.1, 4.2, 4.3 | PN-EN 60851-5:2008+A1:2011 +A2:2020-06 (EN 60851-5:2008+A1:2011+A2:2019, IEC 60851-5:2008+AMD1:2011+ AMD2:2019) pkt. 3 | PN-HD 605 S3:2020-05, pkt. 2.1, 3.1.1 (HD 605 S3:2019) | PN-HD 605 S2:2008 pkt. 3.1.1 (HD 605 S2:2008) | PN-EN 50395:2007+A1:2011 pkt. 5 (EN 50395:2005+A1:2011) | PN-EN 60228:2007 zał. A (EN 60228:2005, IEC 60228:2004) | PN-EN 50289-1-2:2007 (EN 50289-1-2:2001) | PN-EN 50289-1-2:2023-09 (EN 50289-1-2:2023)","norm_bases":["PN-EN 60811-201:2012 (EN 60811-201:2012, IEC 60811-201:2012)","PN-EN 60811-201:2012/A1:2018-02 (EN 60811-201:2012/A1:2017, IEC 60811- 201:2012/AMD1:2017)","PN-EN 60811-201:2012/A2:2024-03 (EN 60811-201:2012/A2:2023, IEC 60811- 201:2012/AMD2:2023)","PN-EN 60811-202:2012 (EN 60811-202:2012, IEC 60811-202:2012)","PN-EN 60811-202:2012/A1:2018-02 (EN 60811-202:2012/A1:2017, IEC 60811- 202:2012/AMD1:2017)","PN-EN 60811-202:2012/A2:2024-03 (EN 60811-202:2012/A2:2023, IEC 60811- 202:2012/AMD2:2023)","PN-EN 60811-203:2012 (EN 60811-203:2012, IEC 60811-203:2012)","PN-EN 60811-100:2012","PN-HD 605 S2:2008 (HD 605 S2:2008) pkt. 2.1.1, 2.1.2, 2.1.3","PN-EN 50396:2007+A1:2011 (EN 50396:2005+A1:2011) pkt 4.1, 4.2, 4.3","PN-EN 60851-5:2008+A1:2011 +A2:2020-06 (EN 60851-5:2008+A1:2011+A2:2019, IEC 60851-5:2008+AMD1:2011+ AMD2:2019) pkt. 3","PN-HD 605 S3:2020-05, pkt. 2.1, 3.1.1 (HD 605 S3:2019)","PN-HD 605 S2:2008 pkt. 3.1.1 (HD 605 S2:2008)","PN-EN 50395:2007+A1:2011 pkt. 5 (EN 50395:2005+A1:2011)","PN-EN 60228:2007 zał. A (EN 60228:2005, IEC 60228:2004)","PN-EN 50289-1-2:2007 (EN 50289-1-2:2001)","PN-EN 50289-1-2:2023-09 (EN 50289-1-2:2023)"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable i przewody napięcie znamionowe do 18/30 kV, średnica zewnętrzna do 100 mm / Electric cables rated voltage up to 18/30 kV, external diameter up to 100 mm Wymiary liniowe, Linear dimensions\nZakres:\ngrubość izolacji (0 - 50) mm\ngrubość powłok niemetalowych (0 - 50) mm\nwymiary zewnętrzne (0 - 300) mm\nRezystancja żył (0 -1999) Ω\ninsulation thickness (0 - 50) mm\nthickness of non-metallic sheath (0 - 50) mm\nExternal dimensions (0 - 300) mm\nConductor resistance (0 - 1999) Ω PN-EN 60811-201:2012 (EN 60811-201:2012, IEC 60811-201:2012) | PN-EN 60811-201:2012/A1:2018-02 (EN 60811-201:2012/A1:2017, IEC 60811- 201:2012/AMD1:2017) | PN-EN 60811-201:2012/A2:2024-03 (EN 60811-201:2012/A2:2023, IEC 60811- 201:2012/AMD2:2023) | PN-EN 60811-202:2012 (EN 60811-202:2012, IEC 60811-202:2012) | PN-EN 60811-202:2012/A1:2018-02 (EN 60811-202:2012/A1:2017, IEC 60811- 202:2012/AMD1:2017) | PN-EN 60811-202:2012/A2:2024-03 (EN 60811-202:2012/A2:2023, IEC 60811- 202:2012/AMD2:2023) | PN-EN 60811-203:2012 (EN 60811-203:2012, IEC 60811-203:2012) | PN-EN 60811-100:2012 | PN-HD 605 S2:2008 (HD 605 S2:2008) pkt. 2.1.1, 2.1.2, 2.1.3 | PN-EN 50396:2007+A1:2011 (EN 50396:2005+A1:2011) pkt 4.1, 4.2, 4.3 | PN-EN 60851-5:2008+A1:2011 +A2:2020-06 (EN 60851-5:2008+A1:2011+A2:2019, IEC 60851-5:2008+AMD1:2011+ AMD2:2019) pkt. 3 | PN-HD 605 S3:2020-05, pkt. 2.1, 3.1.1 (HD 605 S3:2019) | PN-HD 605 S2:2008 pkt. 3.1.1 (HD 605 S2:2008) | PN-EN 50395:2007+A1:2011 pkt. 5 (EN 50395:2005+A1:2011) | PN-EN 60228:2007 zał. A (EN 60228:2005, IEC 60228:2004) | PN-EN 50289-1-2:2007 (EN 50289-1-2:2001) | PN-EN 50289-1-2:2023-09 (EN 50289-1-2:2023) Kable i przewody napiecie znamionowe do 18/30 kV, srednica zewnetrzna do 100 mm / Electric cables rated voltage up to 18/30 kV, external diameter up to 100 mm Wymiary liniowe, Linear dimensions\nZakres:\ngrubosc izolacji (0 - 50) mm\ngrubosc powlok niemetalowych (0 - 50) mm\nwymiary zewnetrzne (0 - 300) mm\nRezystancja zyl (0 -1999) Ω\ninsulation thickness (0 - 50) mm\nthickness of non-metallic sheath (0 - 50) mm\nExternal dimensions (0 - 300) mm\nConductor resistance (0 - 1999) Ω PN-EN 60811-201:2012 (EN 60811-201:2012, IEC 60811-201:2012) | PN-EN 60811-201:2012/A1:2018-02 (EN 60811-201:2012/A1:2017, IEC 60811- 201:2012/AMD1:2017) | PN-EN 60811-201:2012/A2:2024-03 (EN 60811-201:2012/A2:2023, IEC 60811- 201:2012/AMD2:2023) | PN-EN 60811-202:2012 (EN 60811-202:2012, IEC 60811-202:2012) | PN-EN 60811-202:2012/A1:2018-02 (EN 60811-202:2012/A1:2017, IEC 60811- 202:2012/AMD1:2017) | PN-EN 60811-202:2012/A2:2024-03 (EN 60811-202:2012/A2:2023, IEC 60811- 202:2012/AMD2:2023) | PN-EN 60811-203:2012 (EN 60811-203:2012, IEC 60811-203:2012) | PN-EN 60811-100:2012 | PN-HD 605 S2:2008 (HD 605 S2:2008) pkt. 2.1.1, 2.1.2, 2.1.3 | PN-EN 50396:2007+A1:2011 (EN 50396:2005+A1:2011) pkt 4.1, 4.2, 4.3 | PN-EN 60851-5:2008+A1:2011 +A2:2020-06 (EN 60851-5:2008+A1:2011+A2:2019, IEC 60851-5:2008+AMD1:2011+ AMD2:2019) pkt. 3 | PN-HD 605 S3:2020-05, pkt. 2.1, 3.1.1 (HD 605 S3:2019) | PN-HD 605 S2:2008 pkt. 3.1.1 (HD 605 S2:2008) | PN-EN 50395:2007+A1:2011 pkt. 5 (EN 50395:2005+A1:2011) | PN-EN 60228:2007 zal. A (EN 60228:2005, IEC 60228:2004) | PN-EN 50289-1-2:2007 (EN 50289-1-2:2001) | PN-EN 50289-1-2:2023-09 (EN 50289-1-2:2023)","categories":["materials","construction"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"grubość izolacji","range":"(0 - 50) mm"},{"name":"thickness of non-metallic coatings","range":"(0 - 50) mm"},{"name":"external dimensions","range":"(0 - 300) mm"},{"name":"Conductor resistance","range":"(0 -1999) Ω"},{"name":"insulation thickness","range":"(0 - 50) mm"},{"name":"thickness of non-metallic sheath","range":"(0 - 50) mm"},{"name":"External dimensions","range":"(0 - 300) mm"},{"name":"Conductor resistance","range":"(0 - 1999) Ω"}],"search_en":"thickness of non-metallic coatings external dimensions Conductor resistance PN-EN 60811-201:2012 (EN 60811-201:2012, IEC 60811-201:2012) | PN-EN 60811-201:2012/A1:2018-02 (EN 60811-201:2012/A1:2017, IEC 60811- 201:2012/AMD1:2017) | PN-EN 60811-201:2012/A2:2024-03 (EN 60811-201:2012/A2:2023, IEC 60811- 201:2012/AMD2:2023) | PN-EN 60811-202:2012 (EN 60811-202:2012, IEC 60811-202:2012) | PN-EN 60811-202:2012/A1:2018-02 (EN 60811-202:2012/A1:2017, IEC 60811- 202:2012/AMD1:2017) | PN-EN 60811-202:2012/A2:2024-03 (EN 60811-202:2012/A2:2023, IEC 60811- 202:2012/AMD2:2023) | PN-EN 60811-203:2012 (EN 60811-203:2012, IEC 60811-203:2012) | PN-EN 60811-100:2012 | PN-HD 605 S2:2008 (HD 605 S2:2008) pkt. 2.1.1, 2.1.2, 2.1.3 | PN-EN 50396:2007+A1:2011 (EN 50396:2005+A1:2011) pkt 4.1, 4.2, 4.3 | PN-EN 60851-5:2008+A1:2011 +A2:2020-06 (EN 60851-5:2008+A1:2011+A2:2019, IEC 60851-5:2008+AMD1:2011+ AMD2:2019) pkt. 3 | PN-HD 605 S3:2020-05, pkt. 2.1, 3.1.1 (HD 605 S3:2019) | PN-HD 605 S2:2008 pkt. 3.1.1 (HD 605 S2:2008) | PN-EN 50395:2007+A1:2011 pkt. 5 (EN 50395:2005+A1:2011) | PN-EN 60228:2007 zał. A (EN 60228:2005, IEC 60228:2004) | PN-EN 50289-1-2:2007 (EN 50289-1-2:2001) | PN-EN 50289-1-2:2023-09 (EN 50289-1-2:2023)"},{"_id":"6a8369aeaf14b9c0e7b1dbeb","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Znaki bezpieczeństwa / Safety signs","methodology":"Wymiary liniowe","parameters":[{"name":"Wymiary liniowe","range":"(0 - 1000) mm"},{"name":"Linear dimensions","range":"(0 - 1000) mm"}],"technique":"Metoda: bezpośrednia oraz porównawcza z wzorcem wg Rozporządzenia MSWiA (Dz. U. z 2007 r. Nr 143, poz. 1002, Dz. U. z 2010 r. Nr 85 poz. 553) p. 13.1.1, 13.1.2, 13.1.3; Method: direct and comparative with a template according to the Regulation of the Ministry of Interior and Administration (Journal of Laws of 2007 No. 143, item 1002, Journal of Laws of 2010 No. 85 item 553) p. 13.1.1, 13.1.2, 13.1.3","techniques":["Metoda: bezpośrednia oraz porównawcza z wzorcem wg Rozporządzenia MSWiA (Dz. U. z 2007 r. Nr 143, poz. 1002, Dz. U. z 2010 r. Nr 85 poz. 553) p. 13.1.1, 13.1.2, 13.1.3","Method: direct and comparative with a template according to the Regulation of the Ministry of Interior and Administration (Journal of Laws of 2007 No. 143, item 1002, Journal of Laws of 2010 No. 85 item 553) p. 13.1.1, 13.1.2, 13.1.3"],"computed":[],"activity":"Wymiary liniowe\nZakres:\nWymiary liniowe (0 - 1000) mm\nLinear dimensions (0 - 1000) mm\nMetoda: bezpośrednia oraz porównawcza z wzorcem wg Rozporządzenia MSWiA (Dz. U. z 2007 r. Nr 143, poz. 1002, Dz. U. z 2010 r. Nr 85 poz. 553) p. 13.1.1, 13.1.2, 13.1.3; Method: direct and comparative with a template according to the Regulation of the Ministry of Interior and Administration (Journal of Laws of 2007 No. 143, item 1002, Journal of Laws of 2010 No. 85 item 553) p. 13.1.1, 13.1.2, 13.1.3","reference":"PB/BA/01, edycja/edition 3 z/of 03.08.2020","norm_bases":["PB/BA/01, edycja/edition 3 z/of 03.08.2020"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Znaki bezpieczeństwa / Safety signs Wymiary liniowe\nZakres:\nWymiary liniowe (0 - 1000) mm\nLinear dimensions (0 - 1000) mm\nMetoda: bezpośrednia oraz porównawcza z wzorcem wg Rozporządzenia MSWiA (Dz. U. z 2007 r. Nr 143, poz. 1002, Dz. U. z 2010 r. Nr 85 poz. 553) p. 13.1.1, 13.1.2, 13.1.3; Method: direct and comparative with a template according to the Regulation of the Ministry of Interior and Administration (Journal of Laws of 2007 No. 143, item 1002, Journal of Laws of 2010 No. 85 item 553) p. 13.1.1, 13.1.2, 13.1.3 PB/BA/01, edycja/edition 3 z/of 03.08.2020 Znaki bezpieczenstwa / Safety signs Wymiary liniowe\nZakres:\nWymiary liniowe (0 - 1000) mm\nLinear dimensions (0 - 1000) mm\nMetoda: bezposrednia oraz porownawcza z wzorcem wg Rozporzadzenia MSWiA (Dz. U. z 2007 r. Nr 143, poz. 1002, Dz. U. z 2010 r. Nr 85 poz. 553) p. 13.1.1, 13.1.2, 13.1.3; Method: direct and comparative with a template according to the Regulation of the Ministry of Interior and Administration (Journal of Laws of 2007 No. 143, item 1002, Journal of Laws of 2010 No. 85 item 553) p. 13.1.1, 13.1.2, 13.1.3 PB/BA/01, edycja/edition 3 z/of 03.08.2020","categories":["other"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Linear dimensions","parameters_en":[{"name":"Linear dimensions","range":"(0 - 1000) mm"},{"name":"Linear dimensions","range":"(0 - 1000) mm"}],"search_en":"Linear dimensions Linear dimensions Linear dimensions PB/BA/01, edycja/edition 3 z/of 03.08.2020","methodology_zh":"线性尺寸","parameters_zh":[{"name":"线性尺寸","range":"(0 - 1000) mm"},{"name":"Linear dimensions","range":"(0 - 1000) mm"}],"search_zh":"线性尺寸 线性尺寸 PB/BA/01, edycja/edition 3 z/of 03.08.2020"},{"_id":"6a8369aeaf14b9c0e7b1dbec","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Napęd elektromechaniczny do klap pożarowych / Electromechanical operating devices for fire protection equipment","methodology":"Cechy do oceny funkcjonalności napędu elektromechanicznego do klap pożarowych według p. 2, 3 procedury badawczej / Characteristics to functional assessment of the electromechanical operating devices for fire protection equipment according to p. 2, 3 of the laboratory procedure","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności napędu elektromechanicznego do klap pożarowych według p. 2, 3 procedury badawczej / Characteristics to functional assessment of the electromechanical operating devices for fire protection equipment according to p. 2, 3 of the laboratory procedure","reference":"PB/BA/26 edycja/edition 8 z/of 25.03.2019","norm_bases":["PB/BA/26 edycja/edition 8 z/of 25.03.2019"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napęd elektromechaniczny do klap pożarowych / Electromechanical operating devices for fire protection equipment Cechy do oceny funkcjonalności napędu elektromechanicznego do klap pożarowych według p. 2, 3 procedury badawczej / Characteristics to functional assessment of the electromechanical operating devices for fire protection equipment according to p. 2, 3 of the laboratory procedure PB/BA/26 edycja/edition 8 z/of 25.03.2019 Naped elektromechaniczny do klap pozarowych / Electromechanical operating devices for fire protection equipment Cechy do oceny funkcjonalnosci napedu elektromechanicznego do klap pozarowych wedlug p. 2, 3 procedury badawczej / Characteristics to functional assessment of the electromechanical operating devices for fire protection equipment according to p. 2, 3 of the laboratory procedure PB/BA/26 edycja/edition 8 z/of 25.03.2019","categories":["other"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbed","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Sieć central sygnalizacji pożarowej oraz central sterujących urządzeniami przeciwpożarowymi / Network connection between fire protection control panels","methodology":"Cechy do oceny funkcjonalności sieci central według p. 3, 4 procedury badawczej / Characteristics to functional assessment of the network connection between fire protection control panels according to p. 3, 4 of the laboratory procedure","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności sieci central według p. 3, 4 procedury badawczej / Characteristics to functional assessment of the network connection between fire protection control panels according to p. 3, 4 of the laboratory procedure","reference":"PB/BA/41, edycja/edition 9 z/of 10.09.2014","norm_bases":["PB/BA/41, edycja/edition 9 z/of 10.09.2014"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sieć central sygnalizacji pożarowej oraz central sterujących urządzeniami przeciwpożarowymi / Network connection between fire protection control panels Cechy do oceny funkcjonalności sieci central według p. 3, 4 procedury badawczej / Characteristics to functional assessment of the network connection between fire protection control panels according to p. 3, 4 of the laboratory procedure PB/BA/41, edycja/edition 9 z/of 10.09.2014 Siec central sygnalizacji pozarowej oraz central sterujacych urzadzeniami przeciwpozarowymi / Network connection between fire protection control panels Cechy do oceny funkcjonalnosci sieci central wedlug p. 3, 4 procedury badawczej / Characteristics to functional assessment of the network connection between fire protection control panels according to p. 3, 4 of the laboratory procedure PB/BA/41, edycja/edition 9 z/of 10.09.2014","categories":["other"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbee","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Tablica sygnalizacji równoległej / Parallel signalling panel","methodology":"Cechy do oceny funkcjonalności tablicy sygnalizacji równoległej według p. 3, 4, 5, 6 procedury badawczej / Characteristics to functional assessment of the parallel signalling panel according to p. 3, 4, 5, 6 of the laboratory procedure","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności tablicy sygnalizacji równoległej według p. 3, 4, 5, 6 procedury badawczej / Characteristics to functional assessment of the parallel signalling panel according to p. 3, 4, 5, 6 of the laboratory procedure","reference":"PB/BA/42, edycja/edition 6 z/of 09.01.2013","norm_bases":["PB/BA/42, edycja/edition 6 z/of 09.01.2013"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Tablica sygnalizacji równoległej / Parallel signalling panel Cechy do oceny funkcjonalności tablicy sygnalizacji równoległej według p. 3, 4, 5, 6 procedury badawczej / Characteristics to functional assessment of the parallel signalling panel according to p. 3, 4, 5, 6 of the laboratory procedure PB/BA/42, edycja/edition 6 z/of 09.01.2013 Tablica sygnalizacji rownoleglej / Parallel signalling panel Cechy do oceny funkcjonalnosci tablicy sygnalizacji rownoleglej wedlug p. 3, 4, 5, 6 procedury badawczej / Characteristics to functional assessment of the parallel signalling panel according to p. 3, 4, 5, 6 of the laboratory procedure PB/BA/42, edycja/edition 6 z/of 09.01.2013","categories":["other"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbef","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Wskaźnik zadziałania / Operation indicator","methodology":"Cechy do oceny funkcjonalności wskaźnika zadziałania według p. 2, 3 procedury badawczej / Characteristics to functional assessment of the operation indicator according to p. 2, 3 of the laboratory procedure","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności wskaźnika zadziałania według p. 2, 3 procedury badawczej / Characteristics to functional assessment of the operation indicator according to p. 2, 3 of the laboratory procedure","reference":"PB/BA/46 edycja/edition 9 z/of 27.02.2020","norm_bases":["PB/BA/46 edycja/edition 9 z/of 27.02.2020"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wskaźnik zadziałania / Operation indicator Cechy do oceny funkcjonalności wskaźnika zadziałania według p. 2, 3 procedury badawczej / Characteristics to functional assessment of the operation indicator according to p. 2, 3 of the laboratory procedure PB/BA/46 edycja/edition 9 z/of 27.02.2020 Wskaznik zadzialania / Operation indicator Cechy do oceny funkcjonalnosci wskaznika zadzialania wedlug p. 2, 3 procedury badawczej / Characteristics to functional assessment of the operation indicator according to p. 2, 3 of the laboratory procedure PB/BA/46 edycja/edition 9 z/of 27.02.2020","categories":["other"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbf0","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Ręczny przycisk oddymiania / Manual control point, Przycisk przeciwpożarowego wyłącznika prądu / Manual control point of fire switch","methodology":"Cechy do oceny funkcjonalności ręcznego przycisku oddymiania według p. 2, 3 procedury badawczej i p. 4, 5.3, 6.1.8, 6.2.4, 6.2.5, 8, 9, 11, 12, 13 (z wyjątkiem 13.11) normy ISO 21927-9:2012, Characteristics to functional assessment of the manual control point according to p. 2, 3 of the laboratory procedure and p. 4, 5.3, 6.1.8, 6.2.4, 6.2.5, 8, 9, 11, 12, 13 (except 13.11) of the ISO standard, Cechy do oceny funkcjonalności przycisku przeciwpożarowego wyłącznika prądu według p. 2, 3 procedury badawczej / Characteristics to functional assessment of the manual control point of fire switch according to p. 2, 3 of the laboratory procedure","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności ręcznego przycisku oddymiania według p. 2, 3 procedury badawczej i p. 4, 5.3, 6.1.8, 6.2.4, 6.2.5, 8, 9, 11, 12, 13 (z wyjątkiem 13.11) normy ISO 21927-9:2012, Characteristics to functional assessment of the manual control point according to p. 2, 3 of the laboratory procedure and p. 4, 5.3, 6.1.8, 6.2.4, 6.2.5, 8, 9, 11, 12, 13 (except 13.11) of the ISO standard, Cechy do oceny funkcjonalności przycisku przeciwpożarowego wyłącznika prądu według p. 2, 3 procedury badawczej / Characteristics to functional assessment of the manual control point of fire switch according to p. 2, 3 of the laboratory procedure","reference":"PB/BA/47 edycja/edition 8 z /of 25.03.2019 | ISO 21927-9:2012 w tym / including: | p. 8 z wykorzystaniem / using PN-EN 60529:2003+AC:2017-12 | p. 13.2 z wykorzystaniem / using: PN-EN 54-11:2004+A1:2006 | p. 13.3 z wykorzystaniem / using: PN-EN 60068-2-1:2009 | p. 13.4 z wykorzystaniem / using: PN-EN 60068-2-78:2013 | p. 13.5 z wykorzystaniem / using: PN-EN 60068-2-75:2015 | p. 13.6 z wykorzystaniem / using: PN-EN 60068-2-6:2008 | p. 13.7 z wykorzystaniem / using: PN-EN 60068-2-78:2013 | p. 13.8 z wykorzystaniem / using: PN-EN 60068-2-6:2008 | p. 13.9 z wykorzystaniem / using: PN-EN 60068-2-1:2009 | PN-EN 60068-2-2:2009 | p. 13.10 z wykorzystaniem / using: PN-EN ISO 6988:2000 | p. 13.12 z wykorzystaniem / using: PN-EN 60529:2003+AC:2017-12 | p. 13.13 z wykorzystaniem / using: PN-EN 60529:2003+AC:2017-12 | p. 13.14 z wykorzystaniem / using: PN-EN 50130-4:2012+A1:2015-03","norm_bases":["PB/BA/47 edycja/edition 8 z /of 25.03.2019","ISO 21927-9:2012 w tym / including:","p. 8 z wykorzystaniem / using PN-EN 60529:2003+AC:2017-12","p. 13.2 z wykorzystaniem / using: PN-EN 54-11:2004+A1:2006","p. 13.3 z wykorzystaniem / using: PN-EN 60068-2-1:2009","p. 13.4 z wykorzystaniem / using: PN-EN 60068-2-78:2013","p. 13.5 z wykorzystaniem / using: PN-EN 60068-2-75:2015","p. 13.6 z wykorzystaniem / using: PN-EN 60068-2-6:2008","p. 13.7 z wykorzystaniem / using: PN-EN 60068-2-78:2013","p. 13.8 z wykorzystaniem / using: PN-EN 60068-2-6:2008","p. 13.9 z wykorzystaniem / using: PN-EN 60068-2-1:2009","PN-EN 60068-2-2:2009","p. 13.10 z wykorzystaniem / using: PN-EN ISO 6988:2000","p. 13.12 z wykorzystaniem / using: PN-EN 60529:2003+AC:2017-12","p. 13.13 z wykorzystaniem / using: PN-EN 60529:2003+AC:2017-12","p. 13.14 z wykorzystaniem / using: PN-EN 50130-4:2012+A1:2015-03"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ręczny przycisk oddymiania / Manual control point, Przycisk przeciwpożarowego wyłącznika prądu / Manual control point of fire switch Cechy do oceny funkcjonalności ręcznego przycisku oddymiania według p. 2, 3 procedury badawczej i p. 4, 5.3, 6.1.8, 6.2.4, 6.2.5, 8, 9, 11, 12, 13 (z wyjątkiem 13.11) normy ISO 21927-9:2012, Characteristics to functional assessment of the manual control point according to p. 2, 3 of the laboratory procedure and p. 4, 5.3, 6.1.8, 6.2.4, 6.2.5, 8, 9, 11, 12, 13 (except 13.11) of the ISO standard, Cechy do oceny funkcjonalności przycisku przeciwpożarowego wyłącznika prądu według p. 2, 3 procedury badawczej / Characteristics to functional assessment of the manual control point of fire switch according to p. 2, 3 of the laboratory procedure PB/BA/47 edycja/edition 8 z /of 25.03.2019 | ISO 21927-9:2012 w tym / including: | p. 8 z wykorzystaniem / using PN-EN 60529:2003+AC:2017-12 | p. 13.2 z wykorzystaniem / using: PN-EN 54-11:2004+A1:2006 | p. 13.3 z wykorzystaniem / using: PN-EN 60068-2-1:2009 | p. 13.4 z wykorzystaniem / using: PN-EN 60068-2-78:2013 | p. 13.5 z wykorzystaniem / using: PN-EN 60068-2-75:2015 | p. 13.6 z wykorzystaniem / using: PN-EN 60068-2-6:2008 | p. 13.7 z wykorzystaniem / using: PN-EN 60068-2-78:2013 | p. 13.8 z wykorzystaniem / using: PN-EN 60068-2-6:2008 | p. 13.9 z wykorzystaniem / using: PN-EN 60068-2-1:2009 | PN-EN 60068-2-2:2009 | p. 13.10 z wykorzystaniem / using: PN-EN ISO 6988:2000 | p. 13.12 z wykorzystaniem / using: PN-EN 60529:2003+AC:2017-12 | p. 13.13 z wykorzystaniem / using: PN-EN 60529:2003+AC:2017-12 | p. 13.14 z wykorzystaniem / using: PN-EN 50130-4:2012+A1:2015-03 Reczny przycisk oddymiania / Manual control point, Przycisk przeciwpozarowego wylacznika pradu / Manual control point of fire switch Cechy do oceny funkcjonalnosci recznego przycisku oddymiania wedlug p. 2, 3 procedury badawczej i p. 4, 5.3, 6.1.8, 6.2.4, 6.2.5, 8, 9, 11, 12, 13 (z wyjatkiem 13.11) normy ISO 21927-9:2012, Characteristics to functional assessment of the manual control point according to p. 2, 3 of the laboratory procedure and p. 4, 5.3, 6.1.8, 6.2.4, 6.2.5, 8, 9, 11, 12, 13 (except 13.11) of the ISO standard, Cechy do oceny funkcjonalnosci przycisku przeciwpozarowego wylacznika pradu wedlug p. 2, 3 procedury badawczej / Characteristics to functional assessment of the manual control point of fire switch according to p. 2, 3 of the laboratory procedure PB/BA/47 edycja/edition 8 z /of 25.03.2019 | ISO 21927-9:2012 w tym / including: | p. 8 z wykorzystaniem / using PN-EN 60529:2003+AC:2017-12 | p. 13.2 z wykorzystaniem / using: PN-EN 54-11:2004+A1:2006 | p. 13.3 z wykorzystaniem / using: PN-EN 60068-2-1:2009 | p. 13.4 z wykorzystaniem / using: PN-EN 60068-2-78:2013 | p. 13.5 z wykorzystaniem / using: PN-EN 60068-2-75:2015 | p. 13.6 z wykorzystaniem / using: PN-EN 60068-2-6:2008 | p. 13.7 z wykorzystaniem / using: PN-EN 60068-2-78:2013 | p. 13.8 z wykorzystaniem / using: PN-EN 60068-2-6:2008 | p. 13.9 z wykorzystaniem / using: PN-EN 60068-2-1:2009 | PN-EN 60068-2-2:2009 | p. 13.10 z wykorzystaniem / using: PN-EN ISO 6988:2000 | p. 13.12 z wykorzystaniem / using: PN-EN 60529:2003+AC:2017-12 | p. 13.13 z wykorzystaniem / using: PN-EN 60529:2003+AC:2017-12 | p. 13.14 z wykorzystaniem / using: PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbf1","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi/ Control equipment of smoke and heat control systems, Sterownik wentylacji oddymiającej/ Smoke ventilation device","methodology":"Cechy do oceny funkcjonalności centrali i sterownika według p. 2, 3 procedury badawczej i p. 4, 5 (z wyjątkiem 5.3), 6, 7, 8, 9, 10, 11, 12, 13 (z wyjątkiem 13.11) normy ISO 21927-9:2012 / Characteristics to functional assessment of the control equipment according to p. 2, 3 of the laboratory procedure and p. 4, 5 (except 5.3), 6, 7, 8, 9, 10, 11, 12, 13 (except 13.11) of the ISO standard","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności centrali i sterownika według p. 2, 3 procedury badawczej i p. 4, 5 (z wyjątkiem 5.3), 6, 7, 8, 9, 10, 11, 12, 13 (z wyjątkiem 13.11) normy ISO 21927-9:2012 / Characteristics to functional assessment of the control equipment according to p. 2, 3 of the laboratory procedure and p. 4, 5 (except 5.3), 6, 7, 8, 9, 10, 11, 12, 13 (except 13.11) of the ISO standard","reference":"PB/BA/48 edycja/edition 8 z/of 25.03.2019 | ISO 21927-9:2012 w tym / including: | p. 6.3 z wykorzystaniem / using PN-EN 54-5:2003 | PN-EN 54-5+A1:2018-11 | p. 8 z wykorzystaniem / using PN-EN 60529:2003+AC:2017-12 | p. 13.2 z wykorzystaniem / using: PN-EN 54-5:2003 | PN-EN 54-5+A1:2018-11 | PN-EN 54-11:2004+A1:2006 | p. 13.3 z wykorzystaniem / using: PN-EN 60068-2-1:2009 | p. 13.4 z wykorzystaniem / using: PN-EN 60068-2-78:2013 | p. 13.5 z wykorzystaniem / using: PN-EN 60068-2-75:2015 | p. 13.6 z wykorzystaniem / using: PN-EN 60068-2-6:2008 | p. 13.7 z wykorzystaniem / using: PN-EN 60068-2-78:2013 | p. 13.8 z wykorzystaniem / using: PN-EN 60068-2-6:2008 | p. 13.9 z wykorzystaniem / using: PN-EN 60068-2-1:2009 | PN-EN 60068-2-2:2009 | p. 13.10 z wykorzystaniem / using: PN-EN ISO 6988:2000 | p. 13.12 z wykorzystaniem / using: PN-EN 60529:2003+AC:2017-12 | p. 13.13 z wykorzystaniem / using: PN-EN 60529:2003+AC:2017-12 | p. 13.14 z wykorzystaniem / using: PN-EN 50130-4:2012+A1:2015-03","norm_bases":["PB/BA/48 edycja/edition 8 z/of 25.03.2019","ISO 21927-9:2012 w tym / including:","p. 6.3 z wykorzystaniem / using PN-EN 54-5:2003","PN-EN 54-5+A1:2018-11","p. 8 z wykorzystaniem / using PN-EN 60529:2003+AC:2017-12","p. 13.2 z wykorzystaniem / using: PN-EN 54-5:2003","PN-EN 54-5+A1:2018-11","PN-EN 54-11:2004+A1:2006","p. 13.3 z wykorzystaniem / using: PN-EN 60068-2-1:2009","p. 13.4 z wykorzystaniem / using: PN-EN 60068-2-78:2013","p. 13.5 z wykorzystaniem / using: PN-EN 60068-2-75:2015","p. 13.6 z wykorzystaniem / using: PN-EN 60068-2-6:2008","p. 13.7 z wykorzystaniem / using: PN-EN 60068-2-78:2013","p. 13.8 z wykorzystaniem / using: PN-EN 60068-2-6:2008","p. 13.9 z wykorzystaniem / using: PN-EN 60068-2-1:2009","PN-EN 60068-2-2:2009","p. 13.10 z wykorzystaniem / using: PN-EN ISO 6988:2000","p. 13.12 z wykorzystaniem / using: PN-EN 60529:2003+AC:2017-12","p. 13.13 z wykorzystaniem / using: PN-EN 60529:2003+AC:2017-12","p. 13.14 z wykorzystaniem / using: PN-EN 50130-4:2012+A1:2015-03"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Centrala sterująca urządzeniami oddymiającymi i przewietrzającymi/ Control equipment of smoke and heat control systems, Sterownik wentylacji oddymiającej/ Smoke ventilation device Cechy do oceny funkcjonalności centrali i sterownika według p. 2, 3 procedury badawczej i p. 4, 5 (z wyjątkiem 5.3), 6, 7, 8, 9, 10, 11, 12, 13 (z wyjątkiem 13.11) normy ISO 21927-9:2012 / Characteristics to functional assessment of the control equipment according to p. 2, 3 of the laboratory procedure and p. 4, 5 (except 5.3), 6, 7, 8, 9, 10, 11, 12, 13 (except 13.11) of the ISO standard PB/BA/48 edycja/edition 8 z/of 25.03.2019 | ISO 21927-9:2012 w tym / including: | p. 6.3 z wykorzystaniem / using PN-EN 54-5:2003 | PN-EN 54-5+A1:2018-11 | p. 8 z wykorzystaniem / using PN-EN 60529:2003+AC:2017-12 | p. 13.2 z wykorzystaniem / using: PN-EN 54-5:2003 | PN-EN 54-5+A1:2018-11 | PN-EN 54-11:2004+A1:2006 | p. 13.3 z wykorzystaniem / using: PN-EN 60068-2-1:2009 | p. 13.4 z wykorzystaniem / using: PN-EN 60068-2-78:2013 | p. 13.5 z wykorzystaniem / using: PN-EN 60068-2-75:2015 | p. 13.6 z wykorzystaniem / using: PN-EN 60068-2-6:2008 | p. 13.7 z wykorzystaniem / using: PN-EN 60068-2-78:2013 | p. 13.8 z wykorzystaniem / using: PN-EN 60068-2-6:2008 | p. 13.9 z wykorzystaniem / using: PN-EN 60068-2-1:2009 | PN-EN 60068-2-2:2009 | p. 13.10 z wykorzystaniem / using: PN-EN ISO 6988:2000 | p. 13.12 z wykorzystaniem / using: PN-EN 60529:2003+AC:2017-12 | p. 13.13 z wykorzystaniem / using: PN-EN 60529:2003+AC:2017-12 | p. 13.14 z wykorzystaniem / using: PN-EN 50130-4:2012+A1:2015-03 Centrala sterujaca urzadzeniami oddymiajacymi i przewietrzajacymi/ Control equipment of smoke and heat control systems, Sterownik wentylacji oddymiajacej/ Smoke ventilation device Cechy do oceny funkcjonalnosci centrali i sterownika wedlug p. 2, 3 procedury badawczej i p. 4, 5 (z wyjatkiem 5.3), 6, 7, 8, 9, 10, 11, 12, 13 (z wyjatkiem 13.11) normy ISO 21927-9:2012 / Characteristics to functional assessment of the control equipment according to p. 2, 3 of the laboratory procedure and p. 4, 5 (except 5.3), 6, 7, 8, 9, 10, 11, 12, 13 (except 13.11) of the ISO standard PB/BA/48 edycja/edition 8 z/of 25.03.2019 | ISO 21927-9:2012 w tym / including: | p. 6.3 z wykorzystaniem / using PN-EN 54-5:2003 | PN-EN 54-5+A1:2018-11 | p. 8 z wykorzystaniem / using PN-EN 60529:2003+AC:2017-12 | p. 13.2 z wykorzystaniem / using: PN-EN 54-5:2003 | PN-EN 54-5+A1:2018-11 | PN-EN 54-11:2004+A1:2006 | p. 13.3 z wykorzystaniem / using: PN-EN 60068-2-1:2009 | p. 13.4 z wykorzystaniem / using: PN-EN 60068-2-78:2013 | p. 13.5 z wykorzystaniem / using: PN-EN 60068-2-75:2015 | p. 13.6 z wykorzystaniem / using: PN-EN 60068-2-6:2008 | p. 13.7 z wykorzystaniem / using: PN-EN 60068-2-78:2013 | p. 13.8 z wykorzystaniem / using: PN-EN 60068-2-6:2008 | p. 13.9 z wykorzystaniem / using: PN-EN 60068-2-1:2009 | PN-EN 60068-2-2:2009 | p. 13.10 z wykorzystaniem / using: PN-EN ISO 6988:2000 | p. 13.12 z wykorzystaniem / using: PN-EN 60529:2003+AC:2017-12 | p. 13.13 z wykorzystaniem / using: PN-EN 60529:2003+AC:2017-12 | p. 13.14 z wykorzystaniem / using: PN-EN 50130-4:2012+A1:2015-03","categories":["other"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbf2","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Centrala sterująca urządzeniami przeciwpożarowymi / Control panel for fire protection devices, Urządzenie integrujące urządzenia przeciwpożarowe / Device integrating fire protection devices","methodology":"Cechy do oceny funkcjonalności centrali według p. 2, 3, 4 procedury badawczej / Characteristics to functional assessment of the control panel according to p. 2, 3, 4 of the laboratory procedure","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności centrali według p. 2, 3, 4 procedury badawczej / Characteristics to functional assessment of the control panel according to p. 2, 3, 4 of the laboratory procedure","reference":"PB/BA/49, edycja/edition 8 z/of 27.02.2020","norm_bases":["PB/BA/49, edycja/edition 8 z/of 27.02.2020"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Centrala sterująca urządzeniami przeciwpożarowymi / Control panel for fire protection devices, Urządzenie integrujące urządzenia przeciwpożarowe / Device integrating fire protection devices Cechy do oceny funkcjonalności centrali według p. 2, 3, 4 procedury badawczej / Characteristics to functional assessment of the control panel according to p. 2, 3, 4 of the laboratory procedure PB/BA/49, edycja/edition 8 z/of 27.02.2020 Centrala sterujaca urzadzeniami przeciwpozarowymi / Control panel for fire protection devices, Urzadzenie integrujace urzadzenia przeciwpozarowe / Device integrating fire protection devices Cechy do oceny funkcjonalnosci centrali wedlug p. 2, 3, 4 procedury badawczej / Characteristics to functional assessment of the control panel according to p. 2, 3, 4 of the laboratory procedure PB/BA/49, edycja/edition 8 z/of 27.02.2020","categories":["other"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbf3","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Zwalniak elektromagnetyczny / Electromagnetic release unit","methodology":"Cechy do oceny funkcjonalności centrali według p. 2 procedury badawczej / Characteristics to functional assessment of the electromagnetic release unit according to p. 2 of the laboratory procedure","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności centrali według p. 2 procedury badawczej / Characteristics to functional assessment of the electromagnetic release unit according to p. 2 of the laboratory procedure","reference":"PB/BA/52, edycja/edition 6 z/of 09.01.2013","norm_bases":["PB/BA/52, edycja/edition 6 z/of 09.01.2013"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zwalniak elektromagnetyczny / Electromagnetic release unit Cechy do oceny funkcjonalności centrali według p. 2 procedury badawczej / Characteristics to functional assessment of the electromagnetic release unit according to p. 2 of the laboratory procedure PB/BA/52, edycja/edition 6 z/of 09.01.2013 Zwalniak elektromagnetyczny / Electromagnetic release unit Cechy do oceny funkcjonalnosci centrali wedlug p. 2 procedury badawczej / Characteristics to functional assessment of the electromagnetic release unit according to p. 2 of the laboratory procedure PB/BA/52, edycja/edition 6 z/of 09.01.2013","categories":["other"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a8369aeaf14b9c0e7b1dbf4","lab_id":"69ad52a3de79e566650fb16f","country":"PL","accr_number":"AB 207","accr_body":"PCA","test_object":"Urządzenie zdalnej sygnalizacji i obsługi / Remote signalling and service devices","methodology":"Cechy do oceny funkcjonalności centrali według p. 3, 4, 5, 6 procedury badawczej / Characteristics to functional assessment of the remote signalling and service devices according to p. 3, 4, 5, 6 of the laboratory procedure","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cechy do oceny funkcjonalności centrali według p. 3, 4, 5, 6 procedury badawczej / Characteristics to functional assessment of the remote signalling and service devices according to p. 3, 4, 5, 6 of the laboratory procedure","reference":"PB/BA/53, edycja/edition 6 z/of 09.01.2013","norm_bases":["PB/BA/53, edycja/edition 6 z/of 09.01.2013"],"lab_section":"Zespół Laboratoriów Sygnalizacji Alarmu Pożaru i Automatyki Pożarniczej BA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenie zdalnej sygnalizacji i obsługi / Remote signalling and service devices Cechy do oceny funkcjonalności centrali według p. 3, 4, 5, 6 procedury badawczej / Characteristics to functional assessment of the remote signalling and service devices according to p. 3, 4, 5, 6 of the laboratory procedure PB/BA/53, edycja/edition 6 z/of 09.01.2013 Urzadzenie zdalnej sygnalizacji i obslugi / Remote signalling and service devices Cechy do oceny funkcjonalnosci centrali wedlug p. 3, 4, 5, 6 procedury badawczej / Characteristics to functional assessment of the remote signalling and service devices according to p. 3, 4, 5, 6 of the laboratory procedure PB/BA/53, edycja/edition 6 z/of 09.01.2013","categories":["other"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code"}],"has_pdf":true}