{"lab":{"_id":"69ad52a3de79e566650fb16b","accr_number":"AB 201","country":"PL","accr_body":"PCA","address":"ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W BYDGOSZCZY","categories":["water","environment"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":87,"name":"GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_201.pdf"],"scope_summary":"","search_text":"główny inspektorat ochrony środowiska ul. chmielna 132/134, 00-805 warszawa, centralne laboratorium badawcze, oddział w bydgoszczy water environment pharma electronics other metrology microbiology automotive food materials petro","status":"active","updated_at":"2026-03-08T14:51:05.190Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T15:34:07.282Z","location":{"type":"Point","coordinates":[21.0122,52.2297]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20201,podmiot.html","fields_of_testing":[{"codes":"B/32","pl":"Badania biologiczne i pobieranie próbek odpadów, osadów","en":"Biological tests and sampling of waste, sediments"},{"codes":"C/28/P, C/30/P, C/31/P, C/32/P, C/36/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków, gleby, odpadów, osadów, gazów odlotowych","en":"Chemical tests and sampling of water, sewage, waste, soil, sediments, waste gases"},{"codes":"G/34, G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas, pole elektromagnetyczne), gazy odlotowe","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise, electromagnetic field), waste gases"},{"codes":"K/32/P","pl":"Badania mikrobiologiczne i pobieranie próbek odpadów, osadów","en":"Microbiological tests and sampling of waste, sediments"},{"codes":"K/31","pl":"Badania mikrobiologiczne gleby","en":"Microbiological tests of soil"},{"codes":"N/28/P, N/30/P, N/31/P, N/32/P, N/36/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków, gleby, odpadów, osadów, gazów odlotowych","en":"Tests of physical properties and sampling of water, sewage, soil, waste, sediments, waste gases"}],"issue":{"no":"28","date":"12.06.2026"},"parse_date":"2026-08-17T15:34:07.282Z","parse_source":"agent-claude-code","map_coord":[52.227738,20.992749],"map_geo":"nominatim-street","lab_locations":[{"name":"CENTRALNE LABORATORIUM BADAWCZE ODDZIAŁ W BYDGOSZCZY","address":"ul. ks. Piotra Skargi 2 85-018 Bydgoszcz","city":"Bydgoszcz","postal":"85-018"},{"name":"Pracownia Terenowa","address":"ul. ks. Piotra Skargi 2, 85-018 Bydgoszcz","city":"Bydgoszcz","postal":"85-018"},{"name":"Pracownia w Bydgoszczy","address":"ul. ks. Piotra Skargi 2, 85-018 Bydgoszcz","city":"Bydgoszcz","postal":"85-018"},{"name":"Pracownia we Włocławku","address":"ul. Plac Kopernika 1, 87-800 Włocławek","city":"Włocławek","postal":"87-800"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/b3ab22b95cb8ebb93e8688ce20b3d231/AB%20201.pdf","has_en":true,"category_counts":{"water":54,"environment":35,"other":7,"microbiology":2,"petro":2},"category_scores":{"water":29.16,"environment":12.25,"other":0.49,"microbiology":0.04,"petro":0.04},"has_zh":true},"methods":[{"_id":"6a8329ef884ede9a1b2c5265","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Wody powierzchniowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5; 7.6; 10.6 | PN-ISO 5667-4:2017-10","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5; 7.6; 10.6","PN-ISO 5667-4:2017-10"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody powierzchniowe Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5; 7.6; 10.6 | PN-ISO 5667-4:2017-10 Wody powierzchniowe Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt. 7.5; 7.6; 10.6 | PN-ISO 5667-4:2017-10","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Surface waters Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5; 7.6; 10.6 | PN-ISO 5667-4:2017-10","test_object_en":"Surface waters","methodology_zh":"化学与物理检测用样品采集","search_zh":"地表水 化学与物理检测用样品采集 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5; 7.6; 10.6 | PN-ISO 5667-4:2017-10","test_object_zh":"地表水"},{"_id":"6a8329ef884ede9a1b2c5266","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Wody powierzchniowe","methodology":"Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0 – 50) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura pobranej próbki wody\nZakres (0 – 50) °C","reference":"PN-77 C-04584","norm_bases":["PN-77 C-04584"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody powierzchniowe Temperatura pobranej próbki wody\nZakres (0 – 50) °C PN-77 C-04584 Wody powierzchniowe Temperatura pobranej probki wody\nZakres (0 – 50) °C PN-77 C-04584","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of the collected water sample","parameters_en":[{"name":"Range","range":"(0 – 50) °C"}],"search_en":"Surface waters Temperature of the collected water sample Range PN-77 C-04584","test_object_en":"Surface waters","parameters_zh":[{"name":"范围","range":"(0 – 50) °C"}],"search_zh":"地表水 所采水样的温度 范围 PN-77 C-04584","methodology_zh":"所采水样的温度","test_object_zh":"地表水"},{"_id":"6a8329ef884ede9a1b2c5267","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Wody podziemne","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-11:2017-10","norm_bases":["PN-ISO 5667-11:2017-10"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody podziemne Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-11:2017-10 Wody podziemne Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-11:2017-10","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Groundwater Sampling for chemical and physical testing PN-ISO 5667-11:2017-10","test_object_en":"Groundwater","methodology_zh":"化学与物理检测用样品采集","search_zh":"地下水 化学与物理检测用样品采集 PN-ISO 5667-11:2017-10","test_object_zh":"地下水"},{"_id":"6a8329ef884ede9a1b2c5268","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Wody podziemne","methodology":"Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0 – 50) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura pobranej próbki wody\nZakres (0 – 50) °C","reference":"PN-77 C-04584","norm_bases":["PN-77 C-04584"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody podziemne Temperatura pobranej próbki wody\nZakres (0 – 50) °C PN-77 C-04584 Wody podziemne Temperatura pobranej probki wody\nZakres (0 – 50) °C PN-77 C-04584","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of the collected water sample","parameters_en":[{"name":"Range","range":"(0 – 50) °C"}],"search_en":"Groundwater Temperature of the collected water sample Range PN-77 C-04584","test_object_en":"Groundwater","parameters_zh":[{"name":"范围","range":"(0 – 50) °C"}],"search_zh":"地下水 所采水样的温度 范围 PN-77 C-04584","methodology_zh":"所采水样的温度","test_object_zh":"地下水"},{"_id":"6a8329ef884ede9a1b2c5269","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method PN-ISO 5667-10:2021-11","technique_en":"Manual and automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手工与自动法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"手工与自动法"},{"_id":"6a8329ef884ede9a1b2c526a","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura pobranej próbki ścieków","parameters":[{"name":"Zakres","range":"(0 – 50) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura pobranej próbki ścieków\nZakres (0 – 50) °C","reference":"PN-77 C-04584","norm_bases":["PN-77 C-04584"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura pobranej próbki ścieków\nZakres (0 – 50) °C PN-77 C-04584 Scieki Temperatura pobranej probki sciekow\nZakres (0 – 50) °C PN-77 C-04584","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of the collected wastewater sample","parameters_en":[{"name":"Range","range":"(0 – 50) °C"}],"search_en":"Wastewater Temperature of the collected wastewater sample Range PN-77 C-04584","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0 – 50) °C"}],"search_zh":"污水 所采废水样品的温度 范围 PN-77 C-04584","test_object_zh":"污水","methodology_zh":"所采废水样品的温度"},{"_id":"6a8329ef884ede9a1b2c526b","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gleba","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 10381-5:2009","norm_bases":["PN-ISO 10381-5:2009"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 10381-5:2009 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-ISO 10381-5:2009","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Soil Sampling for chemical and physical testing PN-ISO 10381-5:2009","test_object_en":"Soil","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 PN-ISO 10381-5:2009","test_object_zh":"土壤"},{"_id":"6a8329ef884ede9a1b2c526c","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O): kod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych","reference":"PN-EN ISO 5667-13:2011 z wyłączeniem pkt. 6.3.3; 6.3.4; 6.3.5; 6.3.7; 6.3.8; 6.3.9; 6.3.10","norm_bases":["PN-EN ISO 5667-13:2011 z wyłączeniem pkt. 6.3.3; 6.3.4; 6.3.5; 6.3.7; 6.3.8; 6.3.9; 6.3.10"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O): kod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych PN-EN ISO 5667-13:2011 z wyłączeniem pkt. 6.3.3; 6.3.4; 6.3.5; 6.3.7; 6.3.8; 6.3.9; 6.3.10 Osady sciekowe, Odpady O): kod 19 08 05\nO) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Pobieranie probek do badan chemicznych, fizycznych, mikrobiologicznych i parazytologicznych PN-EN ISO 5667-13:2011 z wylaczeniem pkt. 6.3.3; 6.3.4; 6.3.5; 6.3.7; 6.3.8; 6.3.9; 6.3.10","categories":["environment","water","microbiology"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical, microbiological and parasitological testing","search_en":"Sewage sludge, Waste O): code 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Sampling for chemical, physical, microbiological and parasitological testing PN-EN ISO 5667-13:2011 z wyłączeniem pkt. 6.3.3; 6.3.4; 6.3.5; 6.3.7; 6.3.8; 6.3.9; 6.3.10","test_object_en":"Sewage sludge, Waste O): code 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology_zh":"用于化学、物理、微生物与寄生虫学检验的采样","search_zh":"用于化学、物理、微生物与寄生虫学检验的采样 PN-EN ISO 5667-13:2011 z wyłączeniem pkt. 6.3.3; 6.3.4; 6.3.5; 6.3.7; 6.3.8; 6.3.9; 6.3.10"},{"_id":"6a8329ef884ede9a1b2c526d","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Water, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a8329ef884ede9a1b2c526e","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 – 10000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 10000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres (10 – 10000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres (10 – 10000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10 – 10000) μS/cm"}],"search_en":"Water, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 10000) μS/cm"}],"search_zh":"水、废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水"},{"_id":"6a8329ef884ede9a1b2c526f","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(1,0 – 21,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (1,0 – 21,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie tlenu rozpuszczonego\nZakres (1,0 – 21,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda, scieki Stezenie tlenu rozpuszczonego\nZakres (1,0 – 21,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 21,0) mg/l O2"}],"search_en":"Water, wastewater Dissolved oxygen concentration Electrochemical method Range PN-EN ISO 5814:2013-04","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(1,0 – 21,0) mg/l O2"}],"search_zh":"水、废水 溶解氧浓度 电化学法 范围 PN-EN ISO 5814:2013-04","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"溶解氧浓度"},{"_id":"6a8329ef884ede9a1b2c5270","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie tlenu rozpuszczonego jako procentu nasycenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie tlenu rozpuszczonego jako procentu nasycenia (z obliczeń)","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie tlenu rozpuszczonego jako procentu nasycenia (z obliczeń) PN-EN ISO 5814:2013-04 Woda, scieki Stezenie tlenu rozpuszczonego jako procentu nasycenia (z obliczen) PN-EN ISO 5814:2013-04","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration as percentage saturation (calculated)","search_en":"Water, wastewater Dissolved oxygen concentration as percentage saturation (calculated) PN-EN ISO 5814:2013-04","test_object_en":"Water, wastewater","search_zh":"水、废水 PN-EN ISO 5814:2013-04","test_object_zh":"水、废水"},{"_id":"6a8329ef884ede9a1b2c5271","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","parameters":[{"name":"Zakres","range":"(1,0 – 500) mg/m3"}],"technique":"Metoda ciągłej detekcji płomieniowo – jonizacyjnej (FID)","techniques":["Metoda ciągłej detekcji płomieniowo – jonizacyjnej (FID)"],"computed":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (1,0 – 500) mg/m3\nMetoda ciągłej detekcji płomieniowo – jonizacyjnej (FID)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (1,0 – 500) mg/m3\nMetoda ciągłej detekcji płomieniowo – jonizacyjnej (FID) PN-EN 12619:2013-05 Gazy odlotowe Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny\nZakres (1,0 – 500) mg/m3\nMetoda ciaglej detekcji plomieniowo – jonizacyjnej (FID) PN-EN 12619:2013-05","categories":["other"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon","parameters_en":[{"name":"Range","range":"(1,0 – 500) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Continuous flame ionization detection method (FID) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 12619:2013-05","technique_en":"Continuous flame ionization detection method (FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(1,0 – 500) mg/m3"}],"search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物浓度 连续火焰离子化检测法（FID） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 12619:2013-05","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物浓度","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"连续火焰离子化检测法（FID）"},{"_id":"6a8329ef884ede9a1b2c5272","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń) PN-EN 12619:2013-05 Gazy odlotowe Emisja substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny (z obliczen) PN-EN 12619:2013-05","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 12619:2013-05","test_object_en":"Waste gases","search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 12619:2013-05","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a8329ef884ede9a1b2c5273","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek od oznaczania stężeń związków organicznych","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem węgla aktywnego, żelu krzemionkowego i roztworów pochłaniających","techniques":["Metoda aspiracyjna z zastosowaniem węgla aktywnego, żelu krzemionkowego i roztworów pochłaniających"],"computed":[],"activity":"Pobieranie próbek od oznaczania stężeń związków organicznych\nMetoda aspiracyjna z zastosowaniem węgla aktywnego, żelu krzemionkowego i roztworów pochłaniających","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek od oznaczania stężeń związków organicznych\nMetoda aspiracyjna z zastosowaniem węgla aktywnego, żelu krzemionkowego i roztworów pochłaniających PN-Z-04008-4:1999 Gazy odlotowe Pobieranie probek od oznaczania stezen zwiazkow organicznych\nMetoda aspiracyjna z zastosowaniem wegla aktywnego, zelu krzemionkowego i roztworow pochlaniajacych PN-Z-04008-4:1999","categories":["other"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the concentrations of organic compounds","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of the concentrations of organic compounds Aspiration method using activated carbon, silica gel and absorbing solutions Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-Z-04008-4:1999","technique_en":"Aspiration method using activated carbon, silica gel and absorbing solutions","test_object_en":"Waste gases","search_zh":"废气 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-Z-04008-4:1999","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a8329ef884ede9a1b2c5274","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja związków organicznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja związków organicznych (z obliczeń)","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja związków organicznych (z obliczeń) PN-Z-04008-4:1999 Gazy odlotowe Emisja zwiazkow organicznych (z obliczen) PN-Z-04008-4:1999","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of organic compounds (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Emission of organic compounds (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-Z-04008-4:1999","test_object_en":"Waste gases","search_zh":"废气 有机化合物排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-Z-04008-4:1999","test_object_zh":"废气","methodology_zh":"有机化合物排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a8329ef884ede9a1b2c5275","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie dwutlenku siarki, tlenków azotu, tlenku węgla, dwutlenku węgla, tlenu","parameters":[{"name":"SO2","range":"(5,0 – 2860) mg/m3"},{"name":"CO","range":"(7,0 – 2500) mg/m3"},{"name":"CO2","range":"(0,2 – 18,0) %"},{"name":"NOx","range":"(2,0 – 925) mg/m3"},{"name":"O2","range":"(0,2 – 21,0) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda chemiluminescencyjna; Metoda paramagnetyczna","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","Metoda chemiluminescencyjna","Metoda paramagnetyczna"],"computed":[],"activity":"Stężenie dwutlenku siarki, tlenków azotu, tlenku węgla, dwutlenku węgla, tlenu\nZakres:\nSO2 (5,0 – 2860) mg/m3\nCO (7,0 – 2500) mg/m3\nCO2 (0,2 – 18,0) %\nNOx (2,0 – 925) mg/m3\nO2 (0,2 – 21,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda chemiluminescencyjna; Metoda paramagnetyczna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie dwutlenku siarki, tlenków azotu, tlenku węgla, dwutlenku węgla, tlenu\nZakres:\nSO2 (5,0 – 2860) mg/m3\nCO (7,0 – 2500) mg/m3\nCO2 (0,2 – 18,0) %\nNOx (2,0 – 925) mg/m3\nO2 (0,2 – 21,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda chemiluminescencyjna; Metoda paramagnetyczna PN-ISO 10396:2001 Gazy odlotowe Stezenie dwutlenku siarki, tlenkow azotu, tlenku wegla, dwutlenku wegla, tlenu\nZakres:\nSO2 (5,0 – 2860) mg/m3\nCO (7,0 – 2500) mg/m3\nCO2 (0,2 – 18,0) %\nNOx (2,0 – 925) mg/m3\nO2 (0,2 – 21,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda chemiluminescencyjna; Metoda paramagnetyczna PN-ISO 10396:2001","categories":["other"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of sulphur dioxide, nitrogen oxides, carbon monoxide, carbon dioxide, oxygen","parameters_en":[{"name":"SO2","range":"(5,0 – 2860) mg/m3"},{"name":"CO","range":"(7,0 – 2500) mg/m3"},{"name":"CO2","range":"(0,2 – 18,0) %"},{"name":"NOx","range":"(2,0 – 925) mg/m3"},{"name":"O2","range":"(0,2 – 21,0) %"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Concentration of sulphur dioxide, nitrogen oxides, carbon monoxide, carbon dioxide, oxygen Non-dispersive infrared spectrometry (NDIR); Chemiluminescence method; Paramagnetic method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law SO2 CO CO2 NOx O2 PN-ISO 10396:2001","technique_en":"Non-dispersive infrared spectrometry (NDIR); Chemiluminescence method; Paramagnetic method","test_object_en":"Waste gases","search_zh":"废气 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 SO2 CO CO2 NOx O2 PN-ISO 10396:2001","test_object_zh":"废气","parameters_zh":[{"name":"SO2","range":"(5,0 – 2860) mg/m3"},{"name":"CO","range":"(7,0 – 2500) mg/m3"},{"name":"CO2","range":"(0,2 – 18,0) %"},{"name":"NOx","range":"(2,0 – 925) mg/m3"},{"name":"O2","range":"(0,2 – 21,0) %"}],"regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a8329ef884ede9a1b2c5276","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja SO2, NOx (NO i NO2 w przeliczeniu na NO2), CO, CO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja SO2, NOx (NO i NO2 w przeliczeniu na NO2), CO, CO2 (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja SO2, NOx (NO i NO2 w przeliczeniu na NO2), CO, CO2 (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja SO2, NOx (NO i NO2 w przeliczeniu na NO2), CO, CO2 (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of SO2, NOx (NO and NO2 calculated as NO2), CO, CO2 (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Emission of SO2, NOx (NO and NO2 calculated as NO2), CO, CO2 (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-ISO 10396:2001","test_object_en":"Waste gases","search_zh":"废气 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-ISO 10396:2001","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a8329ef884ede9a1b2c5277","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-Z-04030-7:1994","categories":["other"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of dust concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of dust concentration Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 粉尘浓度测定采样 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a8329ef884ede9a1b2c5278","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,001 – 100,0) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,001 – 100,0) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,001 – 100,0) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Gazy odlotowe Stezenie pylu\nZakres (0,001 – 100,0) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,001 – 100,0) g/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust concentration Gravimetric method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-Z-04030-7:1994","technique_en":"Gravimetric method","test_object_en":"Waste gases","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 100,0) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a8329ef884ede9a1b2c5279","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja pylu (z obliczen) PN-Z-04030-7:1994","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 粉尘排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a8329ef884ede9a1b2c527a","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa","parameters":[],"technique":"Metoda spiętrzenia","techniques":["Metoda spiętrzenia"],"computed":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nMetoda spiętrzenia","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nMetoda spiętrzenia PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa\nMetoda spietrzenia PN-Z-04030-7:1994","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Stagnation pressure method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-Z-04030-7:1994","technique_en":"Stagnation pressure method","test_object_en":"Waste gases","search_zh":"废气 动压 > 10 Pa 时的气体体积流量 滞止压力法 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-Z-04030-7:1994","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"动压 > 10 Pa 时的气体体积流量","technique_zh":"滞止压力法"},{"_id":"6a8329ef884ede9a1b2c527b","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych PN-EN 13649:2005 Gazy odlotowe Pobieranie probek do oznaczania stezenia indywidualnych gazowych zwiazkow organicznych PN-EN 13649:2005","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the concentration of individual gaseous organic compounds","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of the concentration of individual gaseous organic compounds Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13649:2005","test_object_en":"Waste gases","search_zh":"废气 单项气态有机化合物浓度测定采样 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13649:2005","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"单项气态有机化合物浓度测定采样"},{"_id":"6a8329ef884ede9a1b2c527c","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja indywidualnych gazowych związków organicznych (z obliczeń) PN-EN 13649:2005 Gazy odlotowe Emisja indywidualnych gazowych zwiazkow organicznych (z obliczen) PN-EN 13649:2005","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of individual gaseous organic compounds (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Emission of individual gaseous organic compounds (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13649:2005","test_object_en":"Waste gases","search_zh":"废气 单项气态有机化合物排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a8329ef884ede9a1b2c527d","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 (Dz. U. Nr 140 poz. 824 i nr 288, poz. 1697) z wyłączeniem punktu H","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 (Dz. U. Nr 140 poz. 824 i nr 288, poz. 1697) z wyłączeniem punktu H"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 (Dz. U. Nr 140 poz. 824 i nr 288, poz. 1697) z wyłączeniem punktu H Srodowisko ogolne - halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 (Dz. U. Nr 140 poz. 824 i nr 288, poz. 1697) z wylaczeniem punktu H","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(24 – 135) dB"}],"search_en":"General environment - noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level Direct measurement method Range Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 (Dz. U. Nr 140 poz. 824 i nr 288, poz. 1697) z wyłączeniem punktu H","technique_en":"Direct measurement method","test_object_en":"General environment - noise from roads, railway lines, tram lines","parameters_zh":[{"name":"范围","range":"(24 – 135) dB"}],"search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 A 计权等效声级 A 计权声暴露级 直接测量法 范围 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 (Dz. U. Nr 140 poz. 824 i nr 288, poz. 1697) z wyłączeniem punktu H","technique_zh":"直接测量法","methodology_zh":"A 计权等效声级 A 计权声暴露级","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a8329ef884ede9a1b2c527e","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 (Dz. U. Nr 140 poz. 824 i nr 288, poz. 1697) z wyłączeniem punktu H","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 (Dz. U. Nr 140 poz. 824 i nr 288, poz. 1697) z wyłączeniem punktu H"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 (Dz. U. Nr 140 poz. 824 i nr 288, poz. 1697) z wyłączeniem punktu H Srodowisko ogolne - halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 (Dz. U. Nr 140 poz. 824 i nr 288, poz. 1697) z wylaczeniem punktu H","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment - noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 (Dz. U. Nr 140 poz. 824 i nr 288, poz. 1697) z wyłączeniem punktu H","test_object_en":"General environment - noise from roads, railway lines, tram lines","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 (Dz. U. Nr 140 poz. 824 i nr 288, poz. 1697) z wyłączeniem punktu H","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a8329ef884ede9a1b2c527f","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 – 134) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (24 – 134) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (24 – 134) dB\nMetoda pomiarowa bezpośrednia Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (24 – 134) dB\nMetoda pomiarowa bezposrednia Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(24 – 134) dB"}],"search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(24 – 134) dB"}],"search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a8329ef884ede9a1b2c5280","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a8329ef884ede9a1b2c5281","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Środowisko ogólne - hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","norm_bases":["Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezpośrednia Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) Srodowisko ogolne - halas impulsowy pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezposrednia Zalacznik Nr 8 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(24 – 135) dB"}],"search_en":"General environment - impulse noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","technique_en":"Direct measurement method","test_object_en":"General environment - impulse noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(24 – 135) dB"}],"search_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声 A 计权等效声级 直接测量法 范围 Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","technique_zh":"直接测量法","test_object_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声"},{"_id":"6a8329ef884ede9a1b2c5282","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Środowisko ogólne - hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","norm_bases":["Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) Srodowisko ogolne - halas impulsowy pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik Nr 8 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment - impulse noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","test_object_en":"General environment - impulse noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","test_object_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声"},{"_id":"6a8329ef884ede9a1b2c5283","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","methodology":"Natężenie pola elektrycznego w zakresie częstotliwości 10 MHz – 60 GHz","parameters":[{"name":"Zakres","range":"(0,8 – 230) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego w zakresie częstotliwości 10 MHz – 60 GHz\nZakres (0,8 – 230) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola elektrycznego w zakresie częstotliwości 10 MHz – 60 GHz\nZakres (0,8 – 230) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola elektrycznego w zakresie czestotliwosci 10 MHz – 60 GHz\nZakres (0,8 – 230) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength in the frequency range 10 MHz – 60 GHz","parameters_en":[{"name":"Range","range":"(0,8 – 230) V/m"}],"search_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength in the frequency range 10 MHz – 60 GHz Direct measurement method Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","parameters_zh":[{"name":"范围","range":"(0,8 – 230) V/m"}],"search_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量） 直接测量法 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a8329ef884ede9a1b2c5284","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości od 10 MHz do 60GHz (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości od 10 MHz do 60GHz (z obliczeń)","reference":"Punkt 3 Załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Punkt 3 Załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego w zakresie częstotliwości od 10 MHz do 60GHz (z obliczeń) Punkt 3 Załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego w zakresie czestotliwosci od 10 MHz do 60GHz (z obliczen) Punkt 3 Zalacznika do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength in the frequency range from 10 MHz to 60GHz (calculated)","search_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength in the frequency range from 10 MHz to 60GHz (calculated) Punkt 3 Załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","test_object_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","search_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量） Punkt 3 Załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","test_object_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a8329ef884ede9a1b2c5285","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Natężenie pola elektrycznego w zakresie częstotliwości 50 Hz","parameters":[{"name":"Zakres","range":"1 Vm – 50 kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego w zakresie częstotliwości 50 Hz\nZakres 1 Vm – 50 kV/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola elektrycznego w zakresie częstotliwości 50 Hz\nZakres 1 Vm – 50 kV/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko - pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola elektrycznego w zakresie czestotliwosci 50 Hz\nZakres 1 Vm – 50 kV/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength in the frequency range 50 Hz","parameters_en":[{"name":"Range","range":"1 Vm – 50 kV/m"}],"search_en":"Environment - electromagnetic field in the vicinity of electric power substations and power lines Electric field strength in the frequency range 50 Hz Direct measurement method Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment - electromagnetic field in the vicinity of electric power substations and power lines","parameters_zh":[{"name":"范围","range":"1 Vm – 50 kV/m"}],"search_zh":"环境 － 变电站与输电线路周围的电磁场 50 Hz 频率范围内的电场强度 直接测量法 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 － 变电站与输电线路周围的电磁场","methodology_zh":"50 Hz 频率范围内的电场强度"},{"_id":"6a8329ef884ede9a1b2c5286","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Indukcja magnetyczna w zakresie częstotliwości 50 Hz","parameters":[{"name":"Zakres","range":"od 1μT do 10 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna w zakresie częstotliwości 50 Hz\nZakres od 1μT do 10 mT\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna w zakresie częstotliwości 50 Hz\nZakres od 1μT do 10 mT\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko - pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna w zakresie czestotliwosci 50 Hz\nZakres od 1μT do 10 mT\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density in the frequency range 50 Hz","parameters_en":[{"name":"Range","range":"od 1μT do 10 mT"}],"search_en":"Environment - electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density in the frequency range 50 Hz Direct measurement method Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment - electromagnetic field in the vicinity of electric power substations and power lines","parameters_zh":[{"name":"范围","range":"od 1μT do 10 mT"}],"search_zh":"环境 － 变电站与输电线路周围的电磁场 50 Hz 频率范围内的磁感应强度 直接测量法 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 － 变电站与输电线路周围的电磁场","methodology_zh":"50 Hz 频率范围内的磁感应强度"},{"_id":"6a8329ef884ede9a1b2c5287","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości 50 Hz (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości 50 Hz (z obliczeń)","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola magnetycznego w zakresie częstotliwości 50 Hz (z obliczeń) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko - pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola magnetycznego w zakresie czestotliwosci 50 Hz (z obliczen) Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength in the frequency range 50 Hz (calculated)","search_en":"Environment - electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength in the frequency range 50 Hz (calculated) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","test_object_en":"Environment - electromagnetic field in the vicinity of electric power substations and power lines","search_zh":"环境 － 变电站与输电线路周围的电磁场 50 Hz 频率范围内的磁场强度（由计算得出） Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","test_object_zh":"环境 － 变电站与输电线路周围的电磁场","methodology_zh":"50 Hz 频率范围内的磁场强度（由计算得出）"},{"_id":"6a8329ef884ede9a1b2c5288","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gleba, Osady ściekowe, Odpady O): kod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Obecność Salmonella spp. w 100g","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Salmonella spp. w 100g\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 6579-1:2017-04 +A1:2020-09 z wyłączeniem punktów 9.5.4; 9.5.6","norm_bases":["PN-EN ISO 6579-1:2017-04 +A1:2020-09 z wyłączeniem punktów 9.5.4; 9.5.6"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, Osady ściekowe, Odpady O): kod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Obecność Salmonella spp. w 100g\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 6579-1:2017-04 +A1:2020-09 z wyłączeniem punktów 9.5.4; 9.5.6 Gleba, Osady sciekowe, Odpady O): kod 19 08 05\nO) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Obecnosc Salmonella spp. w 100g\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 6579-1:2017-04 +A1:2020-09 z wylaczeniem punktow 9.5.4; 9.5.6","categories":["environment","water","microbiology"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp. in 100g","search_en":"Presence of Salmonella spp. in 100g Culture method with biochemical confirmation PN-EN ISO 6579-1:2017-04 +A1:2020-09 z wyłączeniem punktów 9.5.4; 9.5.6","technique_en":"Culture method with biochemical confirmation","search_zh":"培养法结合生化确认 PN-EN ISO 6579-1:2017-04 +A1:2020-09 z wyłączeniem punktów 9.5.4; 9.5.6","technique_zh":"培养法结合生化确认"},{"_id":"6a8329ef884ede9a1b2c5289","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O): kod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp. i Toxocara sp.","parameters":[],"technique":"Metoda flotacyjno-mikroskopowa","techniques":["Metoda flotacyjno-mikroskopowa"],"computed":[],"activity":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp. i Toxocara sp.\nMetoda flotacyjno-mikroskopowa","reference":"PN-Z-19005:2018-10","norm_bases":["PN-Z-19005:2018-10"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O): kod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp. i Toxocara sp.\nMetoda flotacyjno-mikroskopowa PN-Z-19005:2018-10 Osady sciekowe, Odpady O): kod 19 08 05\nO) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Obecnosc i liczba zywych jaj pasozytow jelitowych Ascaris sp., Trichuris sp. i Toxocara sp.\nMetoda flotacyjno-mikroskopowa PN-Z-19005:2018-10","categories":["environment","water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence and count of viable eggs of intestinal parasites Ascaris sp., Trichuris sp. and Toxocara sp.","search_en":"Sewage sludge, Waste O): code 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Presence and count of viable eggs of intestinal parasites Ascaris sp., Trichuris sp. and Toxocara sp. Flotation-microscopic method PN-Z-19005:2018-10","technique_en":"Flotation-microscopic method","test_object_en":"Sewage sludge, Waste O): code 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","search_zh":"浮选-显微镜法 PN-Z-19005:2018-10","technique_zh":"浮选-显微镜法"},{"_id":"6a8329ef884ede9a1b2c528a","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 2000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 2000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a8329ef884ede9a1b2c528b","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand – BOD5","parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand – BOD5 Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a8329ef884ede9a1b2c528c","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","parameters":[{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand – BOD5","parameters_en":[{"name":"Range","range":"(3 – 6000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand – BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a8329ef884ede9a1b2c528d","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (5,0 – 1000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (5,0 – 1000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (5,0 – 1000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand – COD-Cr","parameters_en":[{"name":"Range","range":"(5,0 – 1000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand – COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a8329ef884ede9a1b2c528e","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie rozpuszczonych ortofosforanów","parameters":[{"name":"Zakres","range":"(0,05 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie rozpuszczonych ortofosforanów\nZakres (0,05 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.4","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.4"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie rozpuszczonych ortofosforanów\nZakres (0,05 – 50) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.4 Woda, scieki Stezenie rozpuszczonych ortofosforanow\nZakres (0,05 – 50) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.4","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,05 – 50) mg/l"}],"search_en":"Water, wastewater Dissolved orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.4","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,05 – 50) mg/l"}],"search_zh":"水、废水 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.4","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a8329ef884ede9a1b2c528f","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie rozpuszczonego fosforu fosforanowego","parameters":[{"name":"Zakres","range":"(0,016 – 15) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie rozpuszczonego fosforu fosforanowego\nZakres (0,016 – 15) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.4","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.4"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie rozpuszczonego fosforu fosforanowego\nZakres (0,016 – 15) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.4 Woda, scieki Stezenie rozpuszczonego fosforu fosforanowego\nZakres (0,016 – 15) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.4","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved phosphate phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,016 – 15) mg/l"}],"search_en":"Water, wastewater Dissolved phosphate phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.4","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,016 – 15) mg/l"}],"search_zh":"水、废水 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.4","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a8329ef884ede9a1b2c5290","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,04 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,04 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,04 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,04 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,04 – 10,0) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 10,0) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a8329ef884ede9a1b2c5291","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,05 – 12,8) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,05 – 12,8) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie jonu amonowego\nZakres (0,05 – 12,8) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie jonu amonowego\nZakres (0,05 – 12,8) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,05 – 12,8) mg/l"}],"search_en":"Water, wastewater Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 12,8) mg/l"}],"search_zh":"水、废水 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a8329ef884ede9a1b2c5292","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,004 – 2,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,004 – 2,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,004 – 2,5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,004 – 2,5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,004 – 2,5) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,004 – 2,5) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a8329ef884ede9a1b2c5293","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,013 – 8,2) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,013 – 8,2) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotynów\nZakres (0,013 – 8,2) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotynow\nZakres (0,013 – 8,2) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,013 – 8,2) mg/l"}],"search_en":"Water, wastewater Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,013 – 8,2) mg/l"}],"search_zh":"水、废水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a8329ef884ede9a1b2c5294","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,2 – 10,0) mg/l"},{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda spektrofotometryczna; Metoda miareczkowa","techniques":["Metoda spektrofotometryczna","Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres:\nZakres (0,2 – 10,0) mg/l\nZakres (2,0 – 1000) mg/l\nMetoda spektrofotometryczna; Metoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres:\nZakres (0,2 – 10,0) mg/l\nZakres (2,0 – 1000) mg/l\nMetoda spektrofotometryczna; Metoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres:\nZakres (0,2 – 10,0) mg/l\nZakres (2,0 – 1000) mg/l\nMetoda spektrofotometryczna; Metoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,2 – 10,0) mg/l"},{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Spectrophotometric method; Titrimetric method Range Range PN-EN 25663:2001","technique_en":"Spectrophotometric method; Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,2 – 10,0) mg/l"},{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 分光光度法；滴定法 范围 范围 PN-EN 25663:2001","test_object_zh":"水、废水","technique_zh":"分光光度法；滴定法"},{"_id":"6a8329ef884ede9a1b2c5295","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576.14","norm_bases":["PN-73/C-04576.14"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576.14 Woda, scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576.14","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, wastewater Total nitrogen concentration (calculated) PN-73/C-04576.14","test_object_en":"Water, wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PN-73/C-04576.14","test_object_zh":"水、废水"},{"_id":"6a8329ef884ede9a1b2c5296","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie ogólnego węgla organicznego","parameters":[{"name":"Zakres","range":"(1,0 – 2000) mg/l"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego\nZakres (1,0 – 2000) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie ogólnego węgla organicznego\nZakres (1,0 – 2000) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999 Woda, scieki Stezenie ogolnego wegla organicznego\nZakres (1,0 – 2000) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon concentration","parameters_en":[{"name":"Range","range":"(1,0 – 2000) mg/l"}],"search_en":"Water, wastewater Total organic carbon concentration Spectrometry method in the infrared range IR Range PN-EN 1484:1999","technique_en":"Spectrometry method in the infrared range IR","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(1,0 – 2000) mg/l"}],"search_zh":"水、废水 总有机碳浓度 红外光谱法 IR 范围 PN-EN 1484:1999","test_object_zh":"水、废水","technique_zh":"红外光谱法 IR","methodology_zh":"总有机碳浓度"},{"_id":"6a8329ef884ede9a1b2c5297","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Węglowodory ropopochodne - indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,06 – 150) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Węglowodory ropopochodne - indeks oleju mineralnego\nZakres (0,06 – 150) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Węglowodory ropopochodne - indeks oleju mineralnego\nZakres (0,06 – 150) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki Weglowodory ropopochodne - indeks oleju mineralnego\nZakres (0,06 – 150) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Petroleum hydrocarbons - mineral oil index","parameters_en":[{"name":"Range","range":"(0,06 – 150) mg/l"}],"search_en":"Water, wastewater Petroleum hydrocarbons - mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,06 – 150) mg/l"}],"search_zh":"水、废水 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、废水"},{"_id":"6a8329ef884ede9a1b2c5298","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych WWA","parameters":[{"name":"benzo(b)fluoranten","range":"(0,001 – 0,060) μg/l"},{"name":"benzo(k)fluoranten","range":"(0,001 – 0,060) μg/l"},{"name":"benzo(a)piren","range":"(0,001 – 0,060) μg/l"},{"name":"dibenzo(a,h)antracen","range":"(0,001 – 0,060) μg/l"},{"name":"benzo(g,h,i)perylen","range":"(0,001 – 0,060) μg/l"},{"name":"indeno(1,2,3-c,d)piren","range":"(0,001 – 0,060) μg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych WWA\nZakres:\nbenzo(b)fluoranten (0,001 – 0,060) μg/l\nbenzo(k)fluoranten (0,001 – 0,060) μg/l\nbenzo(a)piren (0,001 – 0,060) μg/l\ndibenzo(a,h)antracen (0,001 – 0,060) μg/l\nbenzo(g,h,i)perylen (0,001 – 0,060) μg/l\nindeno(1,2,3-c,d)piren (0,001 – 0,060) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-EN ISO 17993:2005","norm_bases":["PN-EN ISO 17993:2005"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie wielopierścieniowych węglowodorów aromatycznych WWA\nZakres:\nbenzo(b)fluoranten (0,001 – 0,060) μg/l\nbenzo(k)fluoranten (0,001 – 0,060) μg/l\nbenzo(a)piren (0,001 – 0,060) μg/l\ndibenzo(a,h)antracen (0,001 – 0,060) μg/l\nbenzo(g,h,i)perylen (0,001 – 0,060) μg/l\nindeno(1,2,3-c,d)piren (0,001 – 0,060) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-EN ISO 17993:2005 Woda, scieki Stezenie wielopierscieniowych weglowodorow aromatycznych WWA\nZakres:\nbenzo(b)fluoranten (0,001 – 0,060) μg/l\nbenzo(k)fluoranten (0,001 – 0,060) μg/l\nbenzo(a)piren (0,001 – 0,060) μg/l\ndibenzo(a,h)antracen (0,001 – 0,060) μg/l\nbenzo(g,h,i)perylen (0,001 – 0,060) μg/l\nindeno(1,2,3-c,d)piren (0,001 – 0,060) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-EN ISO 17993:2005","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polycyclic aromatic hydrocarbons PAH concentration","parameters_en":[{"name":"benzo(b)fluoranthene","range":"(0,001 – 0,060) μg/l"},{"name":"benzo(k)fluoranthene","range":"(0,001 – 0,060) μg/l"},{"name":"benzo(a)pyrene","range":"(0,001 – 0,060) μg/l"},{"name":"dibenzo(a,h)anthracene","range":"(0,001 – 0,060) μg/l"},{"name":"benzo(g,h,i)perylene","range":"(0,001 – 0,060) μg/l"},{"name":"indeno(1,2,3-c,d)pyrene","range":"(0,001 – 0,060) μg/l"}],"search_en":"Water, wastewater Polycyclic aromatic hydrocarbons PAH concentration High-performance liquid chromatography with fluorescence detection (HPLC-FLD) benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene dibenzo(a,h)anthracene benzo(g,h,i)perylene indeno(1,2,3-c,d)pyrene PN-EN ISO 17993:2005","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Water, wastewater","search_zh":"水、废水 多环芳烃 PAH 浓度 高效液相色谱-荧光检测法（HPLC-FLD） 苯并（b）荧蒽 苯并（k）荧蒽 苯并（a）芘 二苯并（a,h）蒽 苯并(g,h,i)苝 茚并(1,2,3-c,d)芘 PN-EN ISO 17993:2005","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"水、废水","parameters_zh":[{"name":"苯并（b）荧蒽","range":"(0,001 – 0,060) μg/l"},{"name":"苯并（k）荧蒽","range":"(0,001 – 0,060) μg/l"},{"name":"苯并（a）芘","range":"(0,001 – 0,060) μg/l"},{"name":"二苯并（a,h）蒽","range":"(0,001 – 0,060) μg/l"},{"name":"苯并(g,h,i)苝","range":"(0,001 – 0,060) μg/l"},{"name":"茚并(1,2,3-c,d)芘","range":"(0,001 – 0,060) μg/l"}],"methodology_zh":"多环芳烃 PAH 浓度"},{"_id":"6a8329ef884ede9a1b2c5299","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Suma WWA (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma WWA (z obliczeń)","reference":"PN-EN ISO 17993:2005","norm_bases":["PN-EN ISO 17993:2005"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Suma WWA (z obliczeń) PN-EN ISO 17993:2005 Woda, scieki Suma WWA (z obliczen) PN-EN ISO 17993:2005","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of PAH (calculated)","search_en":"Water, wastewater Sum of PAH (calculated) PN-EN ISO 17993:2005","test_object_en":"Water, wastewater","search_zh":"水、废水 多环芳烃总量（计算值） PN-EN ISO 17993:2005","test_object_zh":"水、废水","methodology_zh":"多环芳烃总量（计算值）"},{"_id":"6a8329ef884ede9a1b2c529a","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,02 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,02 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.7","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.7"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie fosforu ogólnego\nZakres (0,02 – 20) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.7 Woda Stezenie fosforu ogolnego\nZakres (0,02 – 20) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.7","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,02 – 20) mg/l"}],"search_en":"Water Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.7","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 20) mg/l"}],"search_zh":"水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.7","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a8329ef884ede9a1b2c529b","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie związków nieorganicznych","parameters":[{"name":"siarczany","range":"(0,2 – 1400) mg/l"},{"name":"chlorki","range":"(0,2 – 1400) mg/l"},{"name":"azotany","range":"(0,2 – 1400) mg/l"},{"name":"azot azotanowy","range":"(0,045 – 316) mg/l"},{"name":"fluorki","range":"(0,1 – 3,0) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie związków nieorganicznych\nZakres:\nsiarczany (0,2 – 1400) mg/l\nchlorki (0,2 – 1400) mg/l\nazotany (0,2 – 1400) mg/l\nazot azotanowy (0,045 – 316) mg/l\nfluorki (0,1 – 3,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie związków nieorganicznych\nZakres:\nsiarczany (0,2 – 1400) mg/l\nchlorki (0,2 – 1400) mg/l\nazotany (0,2 – 1400) mg/l\nazot azotanowy (0,045 – 316) mg/l\nfluorki (0,1 – 3,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda Stezenie zwiazkow nieorganicznych\nZakres:\nsiarczany (0,2 – 1400) mg/l\nchlorki (0,2 – 1400) mg/l\nazotany (0,2 – 1400) mg/l\nazot azotanowy (0,045 – 316) mg/l\nfluorki (0,1 – 3,0) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of inorganic compounds","parameters_en":[{"name":"sulfates","range":"(0,2 – 1400) mg/l"},{"name":"chlorides","range":"(0,2 – 1400) mg/l"},{"name":"nitrates","range":"(0,2 – 1400) mg/l"},{"name":"nitrate nitrogen","range":"(0,045 – 316) mg/l"},{"name":"fluorides","range":"(0,1 – 3,0) mg/l"}],"search_en":"Water Concentration of inorganic compounds Ion chromatography with conductometric detection (IC-CD) sulfates chlorides nitrates nitrate nitrogen fluorides PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water","search_zh":"水 离子色谱-电导检测法（IC-CD） 硫酸盐 氯化物 硝酸盐 硝酸盐氮 氟化物 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水","parameters_zh":[{"name":"硫酸盐","range":"(0,2 – 1400) mg/l"},{"name":"氯化物","range":"(0,2 – 1400) mg/l"},{"name":"硝酸盐","range":"(0,2 – 1400) mg/l"},{"name":"硝酸盐氮","range":"(0,045 – 316) mg/l"},{"name":"氟化物","range":"(0,1 – 3,0) mg/l"}]},{"_id":"6a8329ef884ede9a1b2c529c","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,05 - 30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,05 - 30) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.8","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.8"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,05 - 30) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.8 Scieki Stezenie fosforu ogolnego\nZakres (0,05 - 30) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.8","categories":["water"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,05 - 30) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.8","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,05 - 30) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.8","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a8329ef884ede9a1b2c529d","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie związków nieorganicznych","parameters":[{"name":"siarczany","range":"(0,2 – 1400) mg/l"},{"name":"chlorki","range":"(0,2 – 1400) mg/l"},{"name":"azotany","range":"(0,2 – 1400) mg/l"},{"name":"azot azotanowy","range":"(0,045 – 316) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie związków nieorganicznych\nZakres:\nsiarczany (0,2 – 1400) mg/l\nchlorki (0,2 – 1400) mg/l\nazotany (0,2 – 1400) mg/l\nazot azotanowy (0,045 – 316) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie związków nieorganicznych\nZakres:\nsiarczany (0,2 – 1400) mg/l\nchlorki (0,2 – 1400) mg/l\nazotany (0,2 – 1400) mg/l\nazot azotanowy (0,045 – 316) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Scieki Stezenie zwiazkow nieorganicznych\nZakres:\nsiarczany (0,2 – 1400) mg/l\nchlorki (0,2 – 1400) mg/l\nazotany (0,2 – 1400) mg/l\nazot azotanowy (0,045 – 316) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of inorganic compounds","parameters_en":[{"name":"sulfates","range":"(0,2 – 1400) mg/l"},{"name":"chlorides","range":"(0,2 – 1400) mg/l"},{"name":"nitrates","range":"(0,2 – 1400) mg/l"},{"name":"nitrate nitrogen","range":"(0,045 – 316) mg/l"}],"search_en":"Wastewater Concentration of inorganic compounds Ion chromatography with conductometric detection (IC-CD) sulfates chlorides nitrates nitrate nitrogen PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Wastewater","search_zh":"污水 离子色谱-电导检测法（IC-CD） 硫酸盐 氯化物 硝酸盐 硝酸盐氮 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"污水","parameters_zh":[{"name":"硫酸盐","range":"(0,2 – 1400) mg/l"},{"name":"氯化物","range":"(0,2 – 1400) mg/l"},{"name":"硝酸盐","range":"(0,2 – 1400) mg/l"},{"name":"硝酸盐氮","range":"(0,045 – 316) mg/l"}]},{"_id":"6a8329ef884ede9a1b2c529e","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gleba","methodology":"Sucha masa","parameters":[{"name":"Zakres","range":"(4,0 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa\nZakres (4,0 – 99,9) %\nMetoda wagowa","reference":"PN- ISO 11465:1999","norm_bases":["PN- ISO 11465:1999"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Sucha masa\nZakres (4,0 – 99,9) %\nMetoda wagowa PN- ISO 11465:1999 Gleba Sucha masa\nZakres (4,0 – 99,9) %\nMetoda wagowa PN- ISO 11465:1999","categories":["environment"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter","parameters_en":[{"name":"Range","range":"(4,0 – 99,9) %"}],"search_en":"Soil Dry matter Gravimetric method Range PN- ISO 11465:1999","technique_en":"Gravimetric method","test_object_en":"Soil","methodology_zh":"干物质","parameters_zh":[{"name":"范围","range":"(4,0 – 99,9) %"}],"search_zh":"土壤 干物质 重量法 范围 PN- ISO 11465:1999","technique_zh":"重量法","test_object_zh":"土壤"},{"_id":"6a8329ef884ede9a1b2c529f","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość wody (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wody (z obliczeń)","reference":"PN- ISO 11465:1999","norm_bases":["PN- ISO 11465:1999"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość wody (z obliczeń) PN- ISO 11465:1999 Gleba Zawartosc wody (z obliczen) PN- ISO 11465:1999","categories":["water","environment"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content (calculated)","search_en":"Soil Water content (calculated) PN- ISO 11465:1999","test_object_en":"Soil","search_zh":"土壤 水分含量（计算值） PN- ISO 11465:1999","test_object_zh":"土壤","methodology_zh":"水分含量（计算值）"},{"_id":"6a8329ef884ede9a1b2c52a0","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gleba","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0– 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0– 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba pH\nZakres 4,0– 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH\nZakres 4,0– 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0– 12,0"}],"search_en":"Soil pH Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Soil","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0– 12,0"}],"search_zh":"土壤 pH 值 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤"},{"_id":"6a8329ef884ede9a1b2c52a1","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gleba","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(50 – 10000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (50 – 10000) μS/cm\nMetoda konduktometryczna","reference":"PN-ISO 11265+AC1:1997","norm_bases":["PN-ISO 11265+AC1:1997"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Przewodność elektryczna właściwa\nZakres (50 – 10000) μS/cm\nMetoda konduktometryczna PN-ISO 11265+AC1:1997 Gleba Przewodnosc elektryczna wlasciwa\nZakres (50 – 10000) μS/cm\nMetoda konduktometryczna PN-ISO 11265+AC1:1997","categories":["environment"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(50 – 10000) μS/cm"}],"search_en":"Soil Electrical conductivity Conductometric method Range PN-ISO 11265+AC1:1997","technique_en":"Conductometric method","test_object_en":"Soil","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(50 – 10000) μS/cm"}],"search_zh":"土壤 电导率 电导法 范围 PN-ISO 11265+AC1:1997","technique_zh":"电导法","test_object_zh":"土壤"},{"_id":"6a8329ef884ede9a1b2c52a2","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość węgla organicznego i całkowita zawartość węgla","parameters":[{"name":"Zakres","range":"(2,0 – 40) g/kg"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla organicznego i całkowita zawartość węgla\nZakres (2,0 – 40) g/kg\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-ISO 10694:2002","norm_bases":["PN-ISO 10694:2002"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość węgla organicznego i całkowita zawartość węgla\nZakres (2,0 – 40) g/kg\nMetoda wysokotemperaturowego spalania z detekcją IR PN-ISO 10694:2002 Gleba Zawartosc wegla organicznego i calkowita zawartosc wegla\nZakres (2,0 – 40) g/kg\nMetoda wysokotemperaturowego spalania z detekcja IR PN-ISO 10694:2002","categories":["environment"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Organic carbon content and total carbon content","parameters_en":[{"name":"Range","range":"(2,0 – 40) g/kg"}],"search_en":"Soil Organic carbon content and total carbon content High-temperature combustion with IR detection Range PN-ISO 10694:2002","technique_en":"High-temperature combustion with IR detection","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(2,0 – 40) g/kg"}],"search_zh":"土壤 高温燃烧红外检测法 范围 PN-ISO 10694:2002","technique_zh":"高温燃烧红外检测法","test_object_zh":"土壤"},{"_id":"6a8329ef884ede9a1b2c52a3","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych WWA:","parameters":[{"name":"naftalen","range":"(0,03 – 7,5) mg/kg"},{"name":"fenantren","range":"(0,03 – 7,5) mg/kg"},{"name":"antracen","range":"(0,03 – 7,5) mg/kg"},{"name":"fluoranten","range":"(0,03 – 7,5) mg/kg"},{"name":"benzo(a)antracen","range":"(0,03 – 7,5) mg/kg"},{"name":"chryzen","range":"(0,03 – 7,5) mg/kg"},{"name":"benzo(a)piren","range":"(0,03 – 7,5) mg/kg"},{"name":"benzo(a)fluoranten","range":"(0,03 – 7,5) mg/kg"},{"name":"benzo(b)fluoranten","range":"(0,03 – 7,50) mg/kg"},{"name":"benzo(k)fluoranten","range":"(0,03 – 7,50) mg/kg"},{"name":"benzo(g,h,i)perylen","range":"(0,03 – 7,5) mg/kg"},{"name":"dibenzo(a,h)antracen","range":"(0,03 – 7,50) mg/kg"},{"name":"indeno(1,2,3-cd)piren","range":"(0,03 – 7,50) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych WWA:\nZakres:\nnaftalen (0,03 – 7,5) mg/kg\nfenantren (0,03 – 7,5) mg/kg\nantracen (0,03 – 7,5) mg/kg\nfluoranten (0,03 – 7,5) mg/kg\nbenzo(a)antracen (0,03 – 7,5) mg/kg\nchryzen (0,03 – 7,5) mg/kg\nbenzo(a)piren (0,03 – 7,5) mg/kg\nbenzo(a)fluoranten (0,03 – 7,5) mg/kg\nbenzo(b)fluoranten (0,03 – 7,50) mg/kg\nbenzo(k)fluoranten (0,03 – 7,50) mg/kg\nbenzo(g,h,i)perylen (0,03 – 7,5) mg/kg\ndibenzo(a,h)antracen (0,03 – 7,50) mg/kg\nindeno(1,2,3-cd)piren (0,03 – 7,50) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"Procedura Badawcza PB-349/BY wydanie 2 z dnia 05.07.2021 r.","norm_bases":["Procedura Badawcza PB-349/BY wydanie 2 z dnia 05.07.2021 r."],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość wielopierścieniowych węglowodorów aromatycznych WWA:\nZakres:\nnaftalen (0,03 – 7,5) mg/kg\nfenantren (0,03 – 7,5) mg/kg\nantracen (0,03 – 7,5) mg/kg\nfluoranten (0,03 – 7,5) mg/kg\nbenzo(a)antracen (0,03 – 7,5) mg/kg\nchryzen (0,03 – 7,5) mg/kg\nbenzo(a)piren (0,03 – 7,5) mg/kg\nbenzo(a)fluoranten (0,03 – 7,5) mg/kg\nbenzo(b)fluoranten (0,03 – 7,50) mg/kg\nbenzo(k)fluoranten (0,03 – 7,50) mg/kg\nbenzo(g,h,i)perylen (0,03 – 7,5) mg/kg\ndibenzo(a,h)antracen (0,03 – 7,50) mg/kg\nindeno(1,2,3-cd)piren (0,03 – 7,50) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Procedura Badawcza PB-349/BY wydanie 2 z dnia 05.07.2021 r. Gleba Zawartosc wielopierscieniowych weglowodorow aromatycznych WWA:\nZakres:\nnaftalen (0,03 – 7,5) mg/kg\nfenantren (0,03 – 7,5) mg/kg\nantracen (0,03 – 7,5) mg/kg\nfluoranten (0,03 – 7,5) mg/kg\nbenzo(a)antracen (0,03 – 7,5) mg/kg\nchryzen (0,03 – 7,5) mg/kg\nbenzo(a)piren (0,03 – 7,5) mg/kg\nbenzo(a)fluoranten (0,03 – 7,5) mg/kg\nbenzo(b)fluoranten (0,03 – 7,50) mg/kg\nbenzo(k)fluoranten (0,03 – 7,50) mg/kg\nbenzo(g,h,i)perylen (0,03 – 7,5) mg/kg\ndibenzo(a,h)antracen (0,03 – 7,50) mg/kg\nindeno(1,2,3-cd)piren (0,03 – 7,50) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) Procedura Badawcza PB-349/BY wydanie 2 z dnia 05.07.2021 r.","categories":["environment"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of polycyclic aromatic hydrocarbons PAH:","parameters_en":[{"name":"naphthalene","range":"(0,03 – 7,5) mg/kg"},{"name":"phenanthrene","range":"(0,03 – 7,5) mg/kg"},{"name":"anthracene","range":"(0,03 – 7,5) mg/kg"},{"name":"fluoranthene","range":"(0,03 – 7,5) mg/kg"},{"name":"benzo(a)anthracene","range":"(0,03 – 7,5) mg/kg"},{"name":"chrysene","range":"(0,03 – 7,5) mg/kg"},{"name":"benzo(a)pyrene","range":"(0,03 – 7,5) mg/kg"},{"name":"benzo(a)fluoranthene","range":"(0,03 – 7,5) mg/kg"},{"name":"benzo(b)fluoranthene","range":"(0,03 – 7,50) mg/kg"},{"name":"benzo(k)fluoranthene","range":"(0,03 – 7,50) mg/kg"},{"name":"benzo(g,h,i)perylene","range":"(0,03 – 7,5) mg/kg"},{"name":"dibenzo(a,h)anthracene","range":"(0,03 – 7,50) mg/kg"},{"name":"indeno(1,2,3-cd)pyrene","range":"(0,03 – 7,50) mg/kg"}],"search_en":"Soil Content of polycyclic aromatic hydrocarbons PAH: High-performance liquid chromatography with fluorescence detection (HPLC-FLD) naphthalene phenanthrene anthracene fluoranthene benzo(a)anthracene chrysene benzo(a)pyrene benzo(a)fluoranthene benzo(b)fluoranthene benzo(k)fluoranthene benzo(g,h,i)perylene dibenzo(a,h)anthracene indeno(1,2,3-cd)pyrene Procedura Badawcza PB-349/BY wydanie 2 z dnia 05.07.2021 r.","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Soil","search_zh":"土壤 高效液相色谱-荧光检测法（HPLC-FLD） 萘 菲 蒽 荧蒽 苯并（a）蒽 䓛 苯并（a）芘 苯并(a)荧蒽 苯并（b）荧蒽 苯并（k）荧蒽 苯并(g,h,i)苝 二苯并（a,h）蒽 茚并(1,2,3-cd)芘 Procedura Badawcza PB-349/BY wydanie 2 z dnia 05.07.2021 r.","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"土壤","parameters_zh":[{"name":"萘","range":"(0,03 – 7,5) mg/kg"},{"name":"菲","range":"(0,03 – 7,5) mg/kg"},{"name":"蒽","range":"(0,03 – 7,5) mg/kg"},{"name":"荧蒽","range":"(0,03 – 7,5) mg/kg"},{"name":"苯并（a）蒽","range":"(0,03 – 7,5) mg/kg"},{"name":"䓛","range":"(0,03 – 7,5) mg/kg"},{"name":"苯并（a）芘","range":"(0,03 – 7,5) mg/kg"},{"name":"苯并(a)荧蒽","range":"(0,03 – 7,5) mg/kg"},{"name":"苯并（b）荧蒽","range":"(0,03 – 7,50) mg/kg"},{"name":"苯并（k）荧蒽","range":"(0,03 – 7,50) mg/kg"},{"name":"苯并(g,h,i)苝","range":"(0,03 – 7,5) mg/kg"},{"name":"二苯并（a,h）蒽","range":"(0,03 – 7,50) mg/kg"},{"name":"茚并(1,2,3-cd)芘","range":"(0,03 – 7,50) mg/kg"}]},{"_id":"6a8329ef884ede9a1b2c52a4","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gleba","methodology":"Suma WWA (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma WWA (z obliczeń)","reference":"Procedura Badawcza PB-349/BY wydanie 2 z dnia 05.07.2021 r.","norm_bases":["Procedura Badawcza PB-349/BY wydanie 2 z dnia 05.07.2021 r."],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Suma WWA (z obliczeń) Procedura Badawcza PB-349/BY wydanie 2 z dnia 05.07.2021 r. Gleba Suma WWA (z obliczen) Procedura Badawcza PB-349/BY wydanie 2 z dnia 05.07.2021 r.","categories":["environment"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of PAH (calculated)","search_en":"Soil Sum of PAH (calculated) Procedura Badawcza PB-349/BY wydanie 2 z dnia 05.07.2021 r.","test_object_en":"Soil","search_zh":"土壤 多环芳烃总量（计算值） Procedura Badawcza PB-349/BY wydanie 2 z dnia 05.07.2021 r.","test_object_zh":"土壤","methodology_zh":"多环芳烃总量（计算值）"},{"_id":"6a8329ef884ede9a1b2c52a5","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość oleju mineralnego (węglowodory C12 – C35)","parameters":[{"name":"Zakres","range":"(30 – 10000) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość oleju mineralnego (węglowodory C12 – C35)\nZakres (30 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 16703:2011","norm_bases":["PN-EN ISO 16703:2011"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość oleju mineralnego (węglowodory C12 – C35)\nZakres (30 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 16703:2011 Gleba Zawartosc oleju mineralnego (weglowodory C12 – C35)\nZakres (30 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 16703:2011","categories":["environment","petro"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil content (C12 – C35 hydrocarbons)","parameters_en":[{"name":"Range","range":"(30 – 10000) mg/kg"}],"search_en":"Soil Mineral oil content (C12 – C35 hydrocarbons) Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 16703:2011","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(30 – 10000) mg/kg"}],"search_zh":"土壤 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 16703:2011","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"土壤"},{"_id":"6a8329ef884ede9a1b2c52a6","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość benzyny (węglowodory C6 – C12)","parameters":[{"name":"Zakres","range":"(1,0 – 500) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość benzyny (węglowodory C6 – C12)\nZakres (1,0 – 500) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Procedura Badawcza PB-371/BY wydanie 1 z dnia 10.06.2024 r.","norm_bases":["Procedura Badawcza PB-371/BY wydanie 1 z dnia 10.06.2024 r."],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość benzyny (węglowodory C6 – C12)\nZakres (1,0 – 500) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Procedura Badawcza PB-371/BY wydanie 1 z dnia 10.06.2024 r. Gleba Zawartosc benzyny (weglowodory C6 – C12)\nZakres (1,0 – 500) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Procedura Badawcza PB-371/BY wydanie 1 z dnia 10.06.2024 r.","categories":["environment"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Petrol content (C6 – C12 hydrocarbons)","parameters_en":[{"name":"Range","range":"(1,0 – 500) mg/kg"}],"search_en":"Soil Petrol content (C6 – C12 hydrocarbons) Gas chromatography with flame ionization detection (GC-FID) Range Procedura Badawcza PB-371/BY wydanie 1 z dnia 10.06.2024 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(1,0 – 500) mg/kg"}],"search_zh":"土壤 气相色谱-氢火焰离子化检测法（GC-FID） 范围 Procedura Badawcza PB-371/BY wydanie 1 z dnia 10.06.2024 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"土壤"},{"_id":"6a8329ef884ede9a1b2c52a7","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O): kod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Sucha masa","parameters":[{"name":"Zakres","range":"(4,0 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa\nZakres (4,0 – 99,9) %\nMetoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O): kod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Sucha masa\nZakres (4,0 – 99,9) %\nMetoda wagowa PN-EN 12880:2004 Osady sciekowe, Odpady O): kod 19 08 05\nO) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Sucha masa\nZakres (4,0 – 99,9) %\nMetoda wagowa PN-EN 12880:2004","categories":["environment","water"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter","parameters_en":[{"name":"Range","range":"(4,0 – 99,9) %"}],"search_en":"Sewage sludge, Waste O): code 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Dry matter Gravimetric method Range PN-EN 12880:2004","technique_en":"Gravimetric method","test_object_en":"Sewage sludge, Waste O): code 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology_zh":"干物质","parameters_zh":[{"name":"范围","range":"(4,0 – 99,9) %"}],"search_zh":"干物质 重量法 范围 PN-EN 12880:2004","technique_zh":"重量法"},{"_id":"6a8329ef884ede9a1b2c52a8","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O): kod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Zawartość wody (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wody (z obliczeń)","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O): kod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Zawartość wody (z obliczeń) PN-EN 12880:2004 Osady sciekowe, Odpady O): kod 19 08 05\nO) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Zawartosc wody (z obliczen) PN-EN 12880:2004","categories":["water","environment"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content (calculated)","search_en":"Sewage sludge, Waste O): code 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Water content (calculated) PN-EN 12880:2004","test_object_en":"Sewage sludge, Waste O): code 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology_zh":"水分含量（计算值）","search_zh":"水分含量（计算值） PN-EN 12880:2004"},{"_id":"6a8329ef884ede9a1b2c52a9","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O): kod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Straty przy prażeniu","parameters":[{"name":"Zakres","range":"(4,0 – 75,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu\nZakres (4,0 – 75,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O): kod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Straty przy prażeniu\nZakres (4,0 – 75,0) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe, Odpady O): kod 19 08 05\nO) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Straty przy prazeniu\nZakres (4,0 – 75,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["environment","water"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition","parameters_en":[{"name":"Range","range":"(4,0 – 75,0) %"}],"search_en":"Sewage sludge, Waste O): code 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Loss on ignition Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Sewage sludge, Waste O): code 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","parameters_zh":[{"name":"范围","range":"(4,0 – 75,0) %"}],"search_zh":"烧失量 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","methodology_zh":"烧失量"},{"_id":"6a8329ef884ede9a1b2c52aa","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O): kod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Zawartość fosforu ogólnego","parameters":[{"name":"Zakres","range":"(5,0 – 2000) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu ogólnego\nZakres (5,0 – 2000) mg/kg\nMetoda spektrofotometryczna","reference":"PN-EN 14672:2006 | PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.8","norm_bases":["PN-EN 14672:2006","PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.8"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O): kod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Zawartość fosforu ogólnego\nZakres (5,0 – 2000) mg/kg\nMetoda spektrofotometryczna PN-EN 14672:2006 | PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.8 Osady sciekowe, Odpady O): kod 19 08 05\nO) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Zawartosc fosforu ogolnego\nZakres (5,0 – 2000) mg/kg\nMetoda spektrofotometryczna PN-EN 14672:2006 | PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.8","categories":["environment","water"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus content","parameters_en":[{"name":"Range","range":"(5,0 – 2000) mg/kg"}],"search_en":"Sewage sludge, Waste O): code 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Total phosphorus content Spectrophotometric method Range PN-EN 14672:2006 | PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.8","technique_en":"Spectrophotometric method","test_object_en":"Sewage sludge, Waste O): code 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","parameters_zh":[{"name":"范围","range":"(5,0 – 2000) mg/kg"}],"search_zh":"总磷含量 分光光度法 范围 PN-EN 14672:2006 | PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 cz.8","technique_zh":"分光光度法","methodology_zh":"总磷含量"},{"_id":"6a8329ef884ede9a1b2c52ab","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O): kod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O): kod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. pH\nZakres 4,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe, Odpady O): kod 19 08 05\nO) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. pH\nZakres 4,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment","water"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 12,0"}],"search_en":"Sewage sludge, Waste O): code 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. pH Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge, Waste O): code 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 12,0"}],"search_zh":"pH 值 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法"},{"_id":"6a8329ef884ede9a1b2c52ac","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobrane na węglu aktywnym","methodology":"Zawartość związków organicznych:","parameters":[{"name":"aceton","range":"(2,2 – 3950) μg w próbce"},{"name":"octan etylu","range":"(4,5 – 1802) μg w próbce"},{"name":"octan butylu","range":"(4,4 – 1763) μg w próbce"},{"name":"benzen","range":"(1,8 – 3520) μg w próbce"},{"name":"toluen","range":"(1,7 – 3460) μg w próbce"},{"name":"etylobenzen","range":"(1,7 – 3460) μg w próbce"},{"name":"(m+p)-ksylen","range":"(3,4 – 6900) μg w próbce"},{"name":"o-ksylen","range":"(1,8 – 3520) μg w próbce"},{"name":"styren","range":"(1,8 – 3640) μg w próbce"},{"name":"węglowodory alifatyczne (suma C5 - C12)","range":"(1,0 – 5606) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość związków organicznych:\nZakres:\naceton (2,2 – 3950) μg w próbce\noctan etylu (4,5 – 1802) μg w próbce\noctan butylu (4,4 – 1763) μg w próbce\nbenzen (1,8 – 3520) μg w próbce\ntoluen (1,7 – 3460) μg w próbce\netylobenzen (1,7 – 3460) μg w próbce\n(m+p)-ksylen (3,4 – 6900) μg w próbce\no-ksylen (1,8 – 3520) μg w próbce\nstyren (1,8 – 3640) μg w próbce\nwęglowodory alifatyczne (suma C5 - C12) (1,0 – 5606) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia w Bydgoszczy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobrane na węglu aktywnym Zawartość związków organicznych:\nZakres:\naceton (2,2 – 3950) μg w próbce\noctan etylu (4,5 – 1802) μg w próbce\noctan butylu (4,4 – 1763) μg w próbce\nbenzen (1,8 – 3520) μg w próbce\ntoluen (1,7 – 3460) μg w próbce\netylobenzen (1,7 – 3460) μg w próbce\n(m+p)-ksylen (3,4 – 6900) μg w próbce\no-ksylen (1,8 – 3520) μg w próbce\nstyren (1,8 – 3640) μg w próbce\nwęglowodory alifatyczne (suma C5 - C12) (1,0 – 5606) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Srodowisko ogolne - probki gazow odlotowych pobrane na weglu aktywnym Zawartosc zwiazkow organicznych:\nZakres:\naceton (2,2 – 3950) μg w probce\noctan etylu (4,5 – 1802) μg w probce\noctan butylu (4,4 – 1763) μg w probce\nbenzen (1,8 – 3520) μg w probce\ntoluen (1,7 – 3460) μg w probce\netylobenzen (1,7 – 3460) μg w probce\n(m+p)-ksylen (3,4 – 6900) μg w probce\no-ksylen (1,8 – 3520) μg w probce\nstyren (1,8 – 3640) μg w probce\nweglowodory alifatyczne (suma C5 - C12) (1,0 – 5606) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["environment"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Organic compound content:","parameters_en":[{"name":"acetone","range":"(2,2 – 3950) μg w próbce"},{"name":"ethyl acetate","range":"(4,5 – 1802) μg w próbce"},{"name":"butyl acetate","range":"(4,4 – 1763) μg w próbce"},{"name":"benzene","range":"(1,8 – 3520) μg w próbce"},{"name":"toluene","range":"(1,7 – 3460) μg w próbce"},{"name":"ethylbenzene","range":"(1,7 – 3460) μg w próbce"},{"name":"(m+p)-xylene","range":"(3,4 – 6900) μg w próbce"},{"name":"o-xylene","range":"(1,8 – 3520) μg w próbce"},{"name":"styrene","range":"(1,8 – 3640) μg w próbce"},{"name":"węglowodory alifatyczne (suma C5 - C12)","range":"(1,0 – 5606) μg w próbce"}],"search_en":"General environment - waste gas samples collected on activated carbon Organic compound content: Gas chromatography with flame ionization detection (GC-FID) acetone ethyl acetate butyl acetate benzene toluene ethylbenzene (m+p)-xylene o-xylene styrene PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"General environment - waste gas samples collected on activated carbon","search_zh":"有机化合物含量： 气相色谱-氢火焰离子化检测法（GC-FID） 丙酮 乙酸乙酯 乙酸丁酯 苯 甲苯 乙苯 (间+对)-二甲苯 邻二甲苯 苯乙烯 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","parameters_zh":[{"name":"丙酮","range":"(2,2 – 3950) μg w próbce"},{"name":"乙酸乙酯","range":"(4,5 – 1802) μg w próbce"},{"name":"乙酸丁酯","range":"(4,4 – 1763) μg w próbce"},{"name":"苯","range":"(1,8 – 3520) μg w próbce"},{"name":"甲苯","range":"(1,7 – 3460) μg w próbce"},{"name":"乙苯","range":"(1,7 – 3460) μg w próbce"},{"name":"(间+对)-二甲苯","range":"(3,4 – 6900) μg w próbce"},{"name":"邻二甲苯","range":"(1,8 – 3520) μg w próbce"},{"name":"苯乙烯","range":"(1,8 – 3640) μg w próbce"},{"name":"węglowodory alifatyczne (suma C5 - C12)","range":"(1,0 – 5606) μg w próbce"}],"methodology_zh":"有机化合物含量："},{"_id":"6a8329ef884ede9a1b2c52ad","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia we Włocławku","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 2000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 2000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a8329ef884ede9a1b2c52ae","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia we Włocławku","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(3 – 6000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a8329ef884ede9a1b2c52af","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia we Włocławku","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a8329ef884ede9a1b2c52b0","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","parameters":[{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia we Włocławku","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand – BOD5","parameters_en":[{"name":"Range","range":"(3 – 6000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand – BOD5 Optical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 光学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a8329ef884ede9a1b2c52b1","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,02 – 64) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,02 – 64) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia we Włocławku","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,02 – 64) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,02 – 64) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,02 – 64) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 64) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a8329ef884ede9a1b2c52b2","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(2 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (2 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia we Włocławku","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (2 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (2 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(2 – 1000) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(2 – 1000) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a8329ef884ede9a1b2c52b3","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,2 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,2 – 10) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia we Włocławku","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (0,2 – 10) mg/l\nMetoda spektrofotometryczna PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (0,2 – 10) mg/l\nMetoda spektrofotometryczna PN-EN 25663:2001","categories":["water"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,2 – 10) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Spectrophotometric method Range PN-EN 25663:2001","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,2 – 10) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 分光光度法 范围 PN-EN 25663:2001","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a8329ef884ede9a1b2c52b4","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,0018 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,0018 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia we Włocławku","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,0018 – 20) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,0018 – 20) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,0018 – 20) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,0018 – 20) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a8329ef884ede9a1b2c52b5","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,04 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,04 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Pracownia we Włocławku","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotanowego\nZakres (0,04 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, scieki Stezenie azotu azotanowego\nZakres (0,04 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,04 – 100) mg/l"}],"search_en":"Water, wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 100) mg/l"}],"search_zh":"水、废水 硝态氮浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a8329ef884ede9a1b2c52b6","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576.14","norm_bases":["PN-73/C-04576.14"],"lab_section":"Pracownia we Włocławku","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576.14 Woda, scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576.14","categories":["water"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, wastewater Total nitrogen concentration (calculated) PN-73/C-04576.14","test_object_en":"Water, wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PN-73/C-04576.14","test_object_zh":"水、废水"},{"_id":"6a8329ef884ede9a1b2c52b7","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie rozpuszczonych ortofosforanów","parameters":[{"name":"Zakres","range":"(0,02 – 500) mg/l (PO43-)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie rozpuszczonych ortofosforanów\nZakres (0,02 – 500) mg/l (PO43-)\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 4","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 4"],"lab_section":"Pracownia we Włocławku","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie rozpuszczonych ortofosforanów\nZakres (0,02 – 500) mg/l (PO43-)\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 4 Woda, scieki Stezenie rozpuszczonych ortofosforanow\nZakres (0,02 – 500) mg/l (PO43-)\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 4","categories":["water"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,02 – 500) mg/l (PO43-)"}],"search_en":"Water, wastewater Dissolved orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 4","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,02 – 500) mg/l (PO43-)"}],"search_zh":"水、废水 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 4","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a8329ef884ede9a1b2c52b8","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,016 – 130) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,016 – 130) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 8","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 8"],"lab_section":"Pracownia we Włocławku","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,016 – 130) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 8 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,016 – 130) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 8","categories":["water"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,016 – 130) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 8","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,016 – 130) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 8","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a8329ef884ede9a1b2c52b9","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr","parameters":[{"name":"Zakres","range":"(30 – 7000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (30 – 7000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":"Pracownia we Włocławku","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (30 – 7000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Woda, scieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (30 – 7000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand – COD-Cr","parameters_en":[{"name":"Range","range":"(30 – 7000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand – COD-Cr Titrimetric method Range PN-ISO 6060:2006","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(30 – 7000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 滴定法 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a8329ef884ede9a1b2c52ba","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie ogólnego węgla organicznego","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego\nZakres (2,0 – 1000) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Pracownia we Włocławku","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie ogólnego węgla organicznego\nZakres (2,0 – 1000) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999 Woda, scieki Stezenie ogolnego wegla organicznego\nZakres (2,0 – 1000) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999","categories":["water"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon concentration","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Water, wastewater Total organic carbon concentration Spectrometry method in the infrared range IR Range PN-EN 1484:1999","technique_en":"Spectrometry method in the infrared range IR","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"水、废水 总有机碳浓度 红外光谱法 IR 范围 PN-EN 1484:1999","test_object_zh":"水、废水","technique_zh":"红外光谱法 IR","methodology_zh":"总有机碳浓度"},{"_id":"6a8329ef884ede9a1b2c52bb","lab_id":"69ad52a3de79e566650fb16b","country":"PL","accr_number":"AB 201","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,016 – 130) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,016 – 130) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 7","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 7"],"lab_section":"Pracownia we Włocławku","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie fosforu ogólnego\nZakres (0,016 – 130) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 7 Woda Stezenie fosforu ogolnego\nZakres (0,016 – 130) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 7","categories":["water"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,016 – 130) mg/l"}],"search_en":"Water Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 7","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,016 – 130) mg/l"}],"search_zh":"水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 punkt 7","technique_zh":"分光光度法","test_object_zh":"水"}],"has_pdf":true}