{"lab":{"_id":"6a9eea8fb186769edc1f54fa","accr_number":"AB 1978","country":"PL","accr_body":"PCA","address":"ul. Grunwaldzka 27C, 63-100 Śrem","categories":["materials"],"city":"Śrem","discovered_at":"2026-09-07T16:47:11.361Z","email_confidence":"high","email_mx":null,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201978,podmiot.html","fields_of_testing":[{"codes":"J/8","pl":"Badania mechaniczne, badania metalograficzne wyrobów i materiałów konstrukcyjnych","en":"Mechanical tests, metallographic tests of construction products and materials"},{"codes":"L/8","pl":"Badania nieniszczące wyrobów i materiałów konstrukcyjnych","en":"Non-destructive tests of construction products and materials"}],"imported_at":"2026-09-07T16:47:11.361Z","methods_count":23,"name":"Laboratorium Badawcze HL LAB Sp. z o.o.","parse_status":"parsed","parse_version":0,"pdf_files":["AB_1978.pdf"],"scope_summary":"Badania mechaniczne, badania metalograficzne; Badania nieniszczące; Wyroby i materiały konstrukcyjne","search_text":"laboratorium badawcze hl lab sp. z o.o. ul. grunwaldzka 27c, 63-100 śrem badania mechaniczne, badania metalograficzne; badania nieniszczące; wyroby i materiały konstrukcyjne ab 1978","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/9/7/89c88ece28368f40c1c81fc22e0c9352/AB%201978.pdf","status":"active","updated_at":"2026-09-07T16:47:11.361Z","valid_from":"26-08-2026","valid_until":"25-08-2030","website":"www.hllab.pl","map_coord":[52.073913,17.024602],"map_geo":"nominatim-street","issue":{"no":"1","date":"26.08.2026"},"lab_locations":[{"name":"LABORATORIUM BADAWCZE HL LAB SP. Z O.O","address":"ul. Grunwaldzka 27C","city":null,"postal":null},{"name":"Laboratorium Badawcze HL LAB Sp. z o.o.","address":"ul. Grunwaldzka 27C, 63-100 Śrem","city":"Śrem","postal":"63-100"}],"parse_date":"2026-09-07T16:53:14.631Z","parse_source":"agent-claude-code","parsed_at":"2026-09-07T16:53:14.631Z","scope_format":"PCA::pracownie+siatka4"},"methods":[{"_id":"6a9eebfa946e48c9e5a92842","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Wyroby i materiały metalowe","methodology":"Niedoskonałości kształtu oraz nieciągłości powierzchniowe zewnętrzne","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Niedoskonałości kształtu oraz nieciągłości powierzchniowe zewnętrzne\nMetoda wizualna","reference":"PN-EN 13018:2016-04","norm_bases":["PN-EN 13018:2016-04"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały metalowe Niedoskonałości kształtu oraz nieciągłości powierzchniowe zewnętrzne\nMetoda wizualna PN-EN 13018:2016-04 Wyroby i materialy metalowe Niedoskonalosci ksztaltu oraz nieciaglosci powierzchniowe zewnetrzne\nMetoda wizualna PN-EN 13018:2016-04","categories":["materials"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eebfa946e48c9e5a92843","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Złącza spawane materiałów metalowych","methodology":"Niedoskonałości kształtu oraz nieciągłości powierzchniowe zewnętrzne","parameters":[],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Niedoskonałości kształtu oraz nieciągłości powierzchniowe zewnętrzne\nMetoda wizualna","reference":"PN-EN ISO 17637:2017-02","norm_bases":["PN-EN ISO 17637:2017-02"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Złącza spawane materiałów metalowych Niedoskonałości kształtu oraz nieciągłości powierzchniowe zewnętrzne\nMetoda wizualna PN-EN ISO 17637:2017-02 Zlacza spawane materialow metalowych Niedoskonalosci ksztaltu oraz nieciaglosci powierzchniowe zewnetrzne\nMetoda wizualna PN-EN ISO 17637:2017-02","categories":["materials"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eebfa946e48c9e5a92844","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Wyroby i materiały metalowe ferromagnetyczne","methodology":"Nieciągłości powierzchniowe i podpowierzchniowe","parameters":[],"technique":"Metoda magnetyczno-proszkowa","techniques":["Metoda magnetyczno-proszkowa"],"computed":[],"activity":"Nieciągłości powierzchniowe i podpowierzchniowe\nMetoda magnetyczno-proszkowa","reference":"PN-EN ISO 9934-1:2017-02","norm_bases":["PN-EN ISO 9934-1:2017-02"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały metalowe ferromagnetyczne Nieciągłości powierzchniowe i podpowierzchniowe\nMetoda magnetyczno-proszkowa PN-EN ISO 9934-1:2017-02 Wyroby i materialy metalowe ferromagnetyczne Nieciaglosci powierzchniowe i podpowierzchniowe\nMetoda magnetyczno-proszkowa PN-EN ISO 9934-1:2017-02","categories":["materials"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eebfa946e48c9e5a92845","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Złącza spawane materiałów ferromagnetycznych","methodology":"Nieciągłości powierzchniowe i podpowierzchniowe","parameters":[],"technique":"Metoda magnetyczno-proszkowa","techniques":["Metoda magnetyczno-proszkowa"],"computed":[],"activity":"Nieciągłości powierzchniowe i podpowierzchniowe\nMetoda magnetyczno-proszkowa","reference":"PN-EN ISO 9934-1:2017-02 | PN-EN ISO 17638:2017-01","norm_bases":["PN-EN ISO 9934-1:2017-02","PN-EN ISO 17638:2017-01"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Złącza spawane materiałów ferromagnetycznych Nieciągłości powierzchniowe i podpowierzchniowe\nMetoda magnetyczno-proszkowa PN-EN ISO 9934-1:2017-02 | PN-EN ISO 17638:2017-01 Zlacza spawane materialow ferromagnetycznych Nieciaglosci powierzchniowe i podpowierzchniowe\nMetoda magnetyczno-proszkowa PN-EN ISO 9934-1:2017-02 | PN-EN ISO 17638:2017-01","categories":["materials"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eebfa946e48c9e5a92846","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Odlewy żeliwne i staliwne ferromagnetyczne","methodology":"Nieciągłości powierzchniowe i podpowierzchniowe","parameters":[],"technique":"Metoda magnetyczno-proszkowa","techniques":["Metoda magnetyczno-proszkowa"],"computed":[],"activity":"Nieciągłości powierzchniowe i podpowierzchniowe\nMetoda magnetyczno-proszkowa","reference":"PN-EN ISO 9934-1:2017-02 | PN-EN 1369:2013-04","norm_bases":["PN-EN ISO 9934-1:2017-02","PN-EN 1369:2013-04"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odlewy żeliwne i staliwne ferromagnetyczne Nieciągłości powierzchniowe i podpowierzchniowe\nMetoda magnetyczno-proszkowa PN-EN ISO 9934-1:2017-02 | PN-EN 1369:2013-04 Odlewy zeliwne i staliwne ferromagnetyczne Nieciaglosci powierzchniowe i podpowierzchniowe\nMetoda magnetyczno-proszkowa PN-EN ISO 9934-1:2017-02 | PN-EN 1369:2013-04","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eebfa946e48c9e5a92847","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Odkuwki stalowe ferromagnetyczne","methodology":"Nieciągłości powierzchniowe i podpowierzchniowe","parameters":[],"technique":"Metoda magnetyczno-proszkowa","techniques":["Metoda magnetyczno-proszkowa"],"computed":[],"activity":"Nieciągłości powierzchniowe i podpowierzchniowe\nMetoda magnetyczno-proszkowa","reference":"PN-EN ISO 9934-1:2017-02 | PN-EN 10228-1:2016-07","norm_bases":["PN-EN ISO 9934-1:2017-02","PN-EN 10228-1:2016-07"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odkuwki stalowe ferromagnetyczne Nieciągłości powierzchniowe i podpowierzchniowe\nMetoda magnetyczno-proszkowa PN-EN ISO 9934-1:2017-02 | PN-EN 10228-1:2016-07 Odkuwki stalowe ferromagnetyczne Nieciaglosci powierzchniowe i podpowierzchniowe\nMetoda magnetyczno-proszkowa PN-EN ISO 9934-1:2017-02 | PN-EN 10228-1:2016-07","categories":["materials"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eebfa946e48c9e5a92848","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Wyroby i materiały metalowe","methodology":"Nieciągłości powierzchniowe zewnętrzne otwarte na badaną powierzchnię","parameters":[],"technique":"Metoda penetracyjna","techniques":["Metoda penetracyjna"],"computed":[],"activity":"Nieciągłości powierzchniowe zewnętrzne otwarte na badaną powierzchnię\nMetoda penetracyjna","reference":"PN-EN ISO 3452-1:2021-12","norm_bases":["PN-EN ISO 3452-1:2021-12"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały metalowe Nieciągłości powierzchniowe zewnętrzne otwarte na badaną powierzchnię\nMetoda penetracyjna PN-EN ISO 3452-1:2021-12 Wyroby i materialy metalowe Nieciaglosci powierzchniowe zewnetrzne otwarte na badana powierzchnie\nMetoda penetracyjna PN-EN ISO 3452-1:2021-12","categories":["materials"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eebfa946e48c9e5a92849","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Odlewy","methodology":"Nieciągłości powierzchniowe zewnętrzne otwarte na badaną powierzchnię","parameters":[],"technique":"Metoda penetracyjna","techniques":["Metoda penetracyjna"],"computed":[],"activity":"Nieciągłości powierzchniowe zewnętrzne otwarte na badaną powierzchnię\nMetoda penetracyjna","reference":"PN-EN ISO 3452-1:2021-12 | PN-EN 1371-1:2012 | PN-EN 1371-2:2015-03","norm_bases":["PN-EN ISO 3452-1:2021-12","PN-EN 1371-1:2012","PN-EN 1371-2:2015-03"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odlewy Nieciągłości powierzchniowe zewnętrzne otwarte na badaną powierzchnię\nMetoda penetracyjna PN-EN ISO 3452-1:2021-12 | PN-EN 1371-1:2012 | PN-EN 1371-2:2015-03 Odlewy Nieciaglosci powierzchniowe zewnetrzne otwarte na badana powierzchnie\nMetoda penetracyjna PN-EN ISO 3452-1:2021-12 | PN-EN 1371-1:2012 | PN-EN 1371-2:2015-03","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eebfa946e48c9e5a9284a","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Odkuwki stalowe","methodology":"Nieciągłości powierzchniowe zewnętrzne otwarte na badaną powierzchnię","parameters":[],"technique":"Metoda penetracyjna","techniques":["Metoda penetracyjna"],"computed":[],"activity":"Nieciągłości powierzchniowe zewnętrzne otwarte na badaną powierzchnię\nMetoda penetracyjna","reference":"PN-EN ISO 3452-1:2021-12 | PN-EN 10228-2:2016-07","norm_bases":["PN-EN ISO 3452-1:2021-12","PN-EN 10228-2:2016-07"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odkuwki stalowe Nieciągłości powierzchniowe zewnętrzne otwarte na badaną powierzchnię\nMetoda penetracyjna PN-EN ISO 3452-1:2021-12 | PN-EN 10228-2:2016-07 Odkuwki stalowe Nieciaglosci powierzchniowe zewnetrzne otwarte na badana powierzchnie\nMetoda penetracyjna PN-EN ISO 3452-1:2021-12 | PN-EN 10228-2:2016-07","categories":["materials"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eebfa946e48c9e5a9284b","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Wyroby i materiały metalowe","methodology":"Nieciągłości","parameters":[],"technique":"Metoda ultradźwiękowa","techniques":["Metoda ultradźwiękowa"],"computed":[],"activity":"Nieciągłości\nMetoda ultradźwiękowa","reference":"PN-EN ISO 16810:2025-04","norm_bases":["PN-EN ISO 16810:2025-04"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały metalowe Nieciągłości\nMetoda ultradźwiękowa PN-EN ISO 16810:2025-04 Wyroby i materialy metalowe Nieciaglosci\nMetoda ultradzwiekowa PN-EN ISO 16810:2025-04","categories":["materials"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eebfa946e48c9e5a9284c","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Wyroby stalowe płaskie","methodology":"Nieciągłości","parameters":[],"technique":"Metoda ultradźwiękowa","techniques":["Metoda ultradźwiękowa"],"computed":[],"activity":"Nieciągłości\nMetoda ultradźwiękowa","reference":"PN-EN 10160:2001","norm_bases":["PN-EN 10160:2001"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby stalowe płaskie Nieciągłości\nMetoda ultradźwiękowa PN-EN 10160:2001 Wyroby stalowe plaskie Nieciaglosci\nMetoda ultradzwiekowa PN-EN 10160:2001","categories":["materials"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eebfa946e48c9e5a9284d","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Odkuwki stalowe","methodology":"Nieciągłości","parameters":[],"technique":"Metoda ultradźwiękowa","techniques":["Metoda ultradźwiękowa"],"computed":[],"activity":"Nieciągłości\nMetoda ultradźwiękowa","reference":"PN-EN 10228-3:2016-07","norm_bases":["PN-EN 10228-3:2016-07"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odkuwki stalowe Nieciągłości\nMetoda ultradźwiękowa PN-EN 10228-3:2016-07 Odkuwki stalowe Nieciaglosci\nMetoda ultradzwiekowa PN-EN 10228-3:2016-07","categories":["materials"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eebfa946e48c9e5a9284e","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Złącza spawane materiałów metalowych","methodology":"Nieciągłości","parameters":[],"technique":"Metoda ultradźwiękowa","techniques":["Metoda ultradźwiękowa"],"computed":[],"activity":"Nieciągłości\nMetoda ultradźwiękowa","reference":"PN-EN ISO 17640:2019-01","norm_bases":["PN-EN ISO 17640:2019-01"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Złącza spawane materiałów metalowych Nieciągłości\nMetoda ultradźwiękowa PN-EN ISO 17640:2019-01 Zlacza spawane materialow metalowych Nieciaglosci\nMetoda ultradzwiekowa PN-EN ISO 17640:2019-01","categories":["materials"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eebfa946e48c9e5a9284f","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Odlewy","methodology":"Nieciągłości","parameters":[],"technique":"Metoda ultradźwiękowa","techniques":["Metoda ultradźwiękowa"],"computed":[],"activity":"Nieciągłości\nMetoda ultradźwiękowa","reference":"PN-EN 12680-1:2026-04 | PN-EN 12680-2:2026-04 | PN-EN 12680-3:2026-04","norm_bases":["PN-EN 12680-1:2026-04","PN-EN 12680-2:2026-04","PN-EN 12680-3:2026-04"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odlewy Nieciągłości\nMetoda ultradźwiękowa PN-EN 12680-1:2026-04 | PN-EN 12680-2:2026-04 | PN-EN 12680-3:2026-04 Odlewy Nieciaglosci\nMetoda ultradzwiekowa PN-EN 12680-1:2026-04 | PN-EN 12680-2:2026-04 | PN-EN 12680-3:2026-04","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eebfa946e48c9e5a92850","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Wyroby i materiały metalowe","methodology":"Grubość","parameters":[{"name":"Zakres","range":"(2,5 - 300) mm"}],"technique":"Metoda ultradźwiękowa","techniques":["Metoda ultradźwiękowa"],"computed":[],"activity":"Grubość\nZakres (2,5 - 300) mm\nMetoda ultradźwiękowa","reference":"PN-EN ISO 16809:2025-12","norm_bases":["PN-EN ISO 16809:2025-12"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały metalowe Grubość\nZakres (2,5 - 300) mm\nMetoda ultradźwiękowa PN-EN ISO 16809:2025-12 Wyroby i materialy metalowe Grubosc\nZakres (2,5 - 300) mm\nMetoda ultradzwiekowa PN-EN ISO 16809:2025-12","categories":["materials"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eebfa946e48c9e5a92851","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Wyroby i materiały metalowe","methodology":"Nieciągłości","parameters":[],"technique":"Metoda radiograficzna","techniques":["Metoda radiograficzna"],"computed":[],"activity":"Nieciągłości\nMetoda radiograficzna","reference":"PN-EN ISO 5579:2014-02","norm_bases":["PN-EN ISO 5579:2014-02"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały metalowe Nieciągłości\nMetoda radiograficzna PN-EN ISO 5579:2014-02 Wyroby i materialy metalowe Nieciaglosci\nMetoda radiograficzna PN-EN ISO 5579:2014-02","categories":["materials"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eebfa946e48c9e5a92852","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Odlewy","methodology":"Nieciągłości","parameters":[],"technique":"Metoda radiograficzna","techniques":["Metoda radiograficzna"],"computed":[],"activity":"Nieciągłości\nMetoda radiograficzna","reference":"PN-EN 12681-1:2018-01","norm_bases":["PN-EN 12681-1:2018-01"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odlewy Nieciągłości\nMetoda radiograficzna PN-EN 12681-1:2018-01 Odlewy Nieciaglosci\nMetoda radiograficzna PN-EN 12681-1:2018-01","categories":["other"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eebfa946e48c9e5a92853","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Złącza spawane materiałów metalowych","methodology":"Nieciągłości","parameters":[],"technique":"Metoda radiograficzna z użyciem błony","techniques":["Metoda radiograficzna z użyciem błony"],"computed":[],"activity":"Nieciągłości\nMetoda radiograficzna z użyciem błony","reference":"PN-EN ISO 17636-1:2023-02","norm_bases":["PN-EN ISO 17636-1:2023-02"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Złącza spawane materiałów metalowych Nieciągłości\nMetoda radiograficzna z użyciem błony PN-EN ISO 17636-1:2023-02 Zlacza spawane materialow metalowych Nieciaglosci\nMetoda radiograficzna z uzyciem blony PN-EN ISO 17636-1:2023-02","categories":["materials"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eebfa946e48c9e5a92854","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Złącza spawane materiałów metalowych","methodology":"Nieciągłości spawalnicze wewnętrzne na powierzchni przełomu złącza spawanego","parameters":[],"technique":"Próba łamania","techniques":["Próba łamania"],"computed":[],"activity":"Nieciągłości spawalnicze wewnętrzne na powierzchni przełomu złącza spawanego\nPróba łamania","reference":"PN-EN ISO 9017:2018-03","norm_bases":["PN-EN ISO 9017:2018-03"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Złącza spawane materiałów metalowych Nieciągłości spawalnicze wewnętrzne na powierzchni przełomu złącza spawanego\nPróba łamania PN-EN ISO 9017:2018-03 Zlacza spawane materialow metalowych Nieciaglosci spawalnicze wewnetrzne na powierzchni przelomu zlacza spawanego\nProba lamania PN-EN ISO 9017:2018-03","categories":["materials"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eebfa946e48c9e5a92855","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Złącza spawane materiałów metalowych","methodology":"Podatność złącza spawanego na odkształcenia plastyczne pod wpływem siły gnącej","parameters":[],"technique":"Próba zginania","techniques":["Próba zginania"],"computed":[],"activity":"Podatność złącza spawanego na odkształcenia plastyczne pod wpływem siły gnącej\nPróba zginania","reference":"PN-EN ISO 5173:2023-06","norm_bases":["PN-EN ISO 5173:2023-06"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Złącza spawane materiałów metalowych Podatność złącza spawanego na odkształcenia plastyczne pod wpływem siły gnącej\nPróba zginania PN-EN ISO 5173:2023-06 Zlacza spawane materialow metalowych Podatnosc zlacza spawanego na odksztalcenia plastyczne pod wplywem sily gnacej\nProba zginania PN-EN ISO 5173:2023-06","categories":["materials"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eebfa946e48c9e5a92856","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Złącza spawane materiałów metalowych, połączenia spajane i warstwy napawane","methodology":"Makrostruktura","parameters":[],"technique":"Badania makroskopowe","techniques":["Badania makroskopowe"],"computed":[],"activity":"Makrostruktura\nBadania makroskopowe","reference":"PN-EN ISO 17639:2022-07","norm_bases":["PN-EN ISO 17639:2022-07"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Złącza spawane materiałów metalowych, połączenia spajane i warstwy napawane Makrostruktura\nBadania makroskopowe PN-EN ISO 17639:2022-07 Zlacza spawane materialow metalowych, polaczenia spajane i warstwy napawane Makrostruktura\nBadania makroskopowe PN-EN ISO 17639:2022-07","categories":["materials"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eebfa946e48c9e5a92857","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Złącza spawane materiałów metalowych","methodology":"Twardość HV","parameters":[{"name":"Zakres","range":"HV 10"}],"technique":"Metoda Vickersa","techniques":["Metoda Vickersa"],"computed":[],"activity":"Twardość HV\nZakres HV 10\nMetoda Vickersa","reference":"PN-EN ISO 9015-1:2011 | PN-EN ISO 6507-1:2024-04","norm_bases":["PN-EN ISO 9015-1:2011","PN-EN ISO 6507-1:2024-04"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Złącza spawane materiałów metalowych Twardość HV\nZakres HV 10\nMetoda Vickersa PN-EN ISO 9015-1:2011 | PN-EN ISO 6507-1:2024-04 Zlacza spawane materialow metalowych Twardosc HV\nZakres HV 10\nMetoda Vickersa PN-EN ISO 9015-1:2011 | PN-EN ISO 6507-1:2024-04","categories":["materials"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eebfa946e48c9e5a92858","lab_id":"6a9eea8fb186769edc1f54fa","country":"PL","accr_number":"AB 1978","accr_body":"PCA","test_object":"Materiał podstawowy do spajania i stopiwo, połączenia spajane i warstwy napawane","methodology":"Twardość HV","parameters":[{"name":"Zakres","range":"HV 10"}],"technique":"Metoda Vickersa","techniques":["Metoda Vickersa"],"computed":[],"activity":"Twardość HV\nZakres HV 10\nMetoda Vickersa","reference":"PN-EN ISO 9015-1:2011 | PN-EN ISO 6507-1:2024-04","norm_bases":["PN-EN ISO 9015-1:2011","PN-EN ISO 6507-1:2024-04"],"lab_section":"Laboratorium Badawcze HL LAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał podstawowy do spajania i stopiwo, połączenia spajane i warstwy napawane Twardość HV\nZakres HV 10\nMetoda Vickersa PN-EN ISO 9015-1:2011 | PN-EN ISO 6507-1:2024-04 Material podstawowy do spajania i stopiwo, polaczenia spajane i warstwy napawane Twardosc HV\nZakres HV 10\nMetoda Vickersa PN-EN ISO 9015-1:2011 | PN-EN ISO 6507-1:2024-04","categories":["materials"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code"}],"has_pdf":false}