{"lab":{"_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","address":"ul. Podgórki Tynieckie 2, 30-399 Kraków","categories":["electronics","construction"],"city":"Kraków","discovered_at":"2026-09-07T16:47:09.543Z","email_confidence":"high","email_mx":null,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201974,podmiot.html","fields_of_testing":[{"codes":"E/6","pl":"Badania elektryczne i elektroniczne wyrobów i wyposażenia elektrycznego","en":"Electric and electronic tests of electrical products and equipment"},{"codes":"J/6","pl":"Badania mechaniczne wyrobów i wyposażenia elektrycznego","en":"Mechanical tests of electrical products and equipment"},{"codes":"N/6","pl":"Badania właściwości fizycznych wyrobów i wyposażenia elektrycznego","en":"Tests of physical properties of electrical products and equipment"},{"table_columns_pl":"Przedmiot badań/wyrób | Rodzaj działalności/ badane cechy/metoda | Dokumenty odniesienia","table_columns_en":"Material / product tested | Type of activity/ parameter/ characteristic tested | Reference documents"},{"note_pl":"Laboratorium przedstawia opinie i interpretacje w sprawozdaniach z badań w oparciu o wyniki badań wykonanych metodami wskazanymi w kolumnie 3 znakiem - „ * ”","note_en":"The laboratory presents opinions and interpretations in test reports based on the results of tests performed using the methods indicated in column 3 with the symbol - „ * ”"}],"imported_at":"2026-09-07T16:47:09.543Z","methods_count":73,"name":"Cyprium Poland Sp. z o. o.","parse_status":"parsed","parse_version":0,"pdf_files":["AB_1974.pdf"],"scope_summary":"Badania elektryczne i elektroniczne; Badania mechaniczne, badania metalograficzne; Badania właściwości fizycznych; Wyroby i wyposażenie elektryczne","search_text":"cyprium poland sp. z o. o. ul. podgórki tynieckie 2, 30-399 kraków badania elektryczne i elektroniczne; badania mechaniczne, badania metalograficzne; badania właściwości fizycznych; wyroby i wyposażenie elektryczne ab 1974","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/9/7/15b2e28eda65ddb03589d732aec52229/AB%201974.pdf","status":"active","updated_at":"2026-09-07T16:47:09.543Z","valid_from":"18-08-2026","valid_until":"17-08-2030","website":"www.aptiv.com/pl/rozwiazania/laboratoria-badawcze/laboratorium-pv-t","map_coord":[49.99832,19.851638],"map_geo":"nominatim-street","issue":{"no":"1","date":"18.08.2026"},"parse_date":"2026-09-07T17:31:49.470Z","parse_source":"agent-claude-code","parsed_at":"2026-09-07T17:31:49.470Z","scope_format":"PCA::pracownie+siatka5"},"methods":[{"_id":"6a9ef505a4e73262d7f6d949","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment","methodology":"Badania wizualne, manualne i funkcjonalne / Visual, manual and functional tests","parameters":[{"name":"Zakres","range":"powiększenie do 500 x"},{"name":"Range","range":"magnificent up to 500 x"}],"technique":null,"techniques":[],"computed":[],"activity":"Badania wizualne, manualne i funkcjonalne / Visual, manual and functional tests\nZakres:\nZakres powiększenie do 500 x\nRange magnificent up to 500 x","reference":"IEC 60512-1-1:2002 | ISO 8092-2:2005-12-01 (p. 4.2) | ISO 8092-2:2023-09 (p. 4.2) | ISO 8092-5:2021-01 (p. 4.2, 4.5) | ISO 19072-2:2019-12 (p. 4.2) | ISO 19072-2:2007-10-01 (p. 4.2) | VW 75174:2018-10 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2; P 0.1; P 6.2; P 6.3; P 14.2; L 8.1; L 5.1; L 5.2; L 15.1; L 18.1; L 19.8; L 20.4; P 21.1; L 23.2) | VW 80332:2024-01 (TG 0, TG 1) | LV 214:2010-03 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) | GS 95006-7-1:2016-03 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) | GS 95006-7-1:2021-11 (E 0.1 z wyłączeniem oceny w paragrafie 6.18.3; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.4) | MBN 10384:2010-11 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) | SAE/USCAR-2:2020-02 (p. 5.1.7, 5.1.8) | SAE/USCAR-2:2022-06 (p. 5.1.7, 5.1.8) | SAE/USCAR-2:2024-12 (p. 5.1.7, 5.1.8) | SAE/USCAR-21:2020-01 (p. 4.2; 4.3) | A 009 000 04 99:2013-07 (p. 3.1; 3.11; 3.12)","norm_bases":["IEC 60512-1-1:2002","ISO 8092-2:2005-12-01 (p. 4.2)","ISO 8092-2:2023-09 (p. 4.2)","ISO 8092-5:2021-01 (p. 4.2, 4.5)","ISO 19072-2:2019-12 (p. 4.2)","ISO 19072-2:2007-10-01 (p. 4.2)","VW 75174:2018-10 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2; P 0.1; P 6.2; P 6.3; P 14.2; L 8.1; L 5.1; L 5.2; L 15.1; L 18.1; L 19.8; L 20.4; P 21.1; L 23.2)","VW 80332:2024-01 (TG 0, TG 1)","LV 214:2010-03 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2)","GS 95006-7-1:2016-03 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2)","GS 95006-7-1:2021-11 (E 0.1 z wyłączeniem oceny w paragrafie 6.18.3; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.4)","MBN 10384:2010-11 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2)","SAE/USCAR-2:2020-02 (p. 5.1.7, 5.1.8)","SAE/USCAR-2:2022-06 (p. 5.1.7, 5.1.8)","SAE/USCAR-2:2024-12 (p. 5.1.7, 5.1.8)","SAE/USCAR-21:2020-01 (p. 4.2; 4.3)","A 009 000 04 99:2013-07 (p. 3.1; 3.11; 3.12)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment Badania wizualne, manualne i funkcjonalne / Visual, manual and functional tests\nZakres:\nZakres powiększenie do 500 x\nRange magnificent up to 500 x IEC 60512-1-1:2002 | ISO 8092-2:2005-12-01 (p. 4.2) | ISO 8092-2:2023-09 (p. 4.2) | ISO 8092-5:2021-01 (p. 4.2, 4.5) | ISO 19072-2:2019-12 (p. 4.2) | ISO 19072-2:2007-10-01 (p. 4.2) | VW 75174:2018-10 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2; P 0.1; P 6.2; P 6.3; P 14.2; L 8.1; L 5.1; L 5.2; L 15.1; L 18.1; L 19.8; L 20.4; P 21.1; L 23.2) | VW 80332:2024-01 (TG 0, TG 1) | LV 214:2010-03 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) | GS 95006-7-1:2016-03 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) | GS 95006-7-1:2021-11 (E 0.1 z wyłączeniem oceny w paragrafie 6.18.3; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.4) | MBN 10384:2010-11 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) | SAE/USCAR-2:2020-02 (p. 5.1.7, 5.1.8) | SAE/USCAR-2:2022-06 (p. 5.1.7, 5.1.8) | SAE/USCAR-2:2024-12 (p. 5.1.7, 5.1.8) | SAE/USCAR-21:2020-01 (p. 4.2; 4.3) | A 009 000 04 99:2013-07 (p. 3.1; 3.11; 3.12) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow / Components of cars’ electric and electronic equipment Badania wizualne, manualne i funkcjonalne / Visual, manual and functional tests\nZakres:\nZakres powiekszenie do 500 x\nRange magnificent up to 500 x IEC 60512-1-1:2002 | ISO 8092-2:2005-12-01 (p. 4.2) | ISO 8092-2:2023-09 (p. 4.2) | ISO 8092-5:2021-01 (p. 4.2, 4.5) | ISO 19072-2:2019-12 (p. 4.2) | ISO 19072-2:2007-10-01 (p. 4.2) | VW 75174:2018-10 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2; P 0.1; P 6.2; P 6.3; P 14.2; L 8.1; L 5.1; L 5.2; L 15.1; L 18.1; L 19.8; L 20.4; P 21.1; L 23.2) | VW 80332:2024-01 (TG 0, TG 1) | LV 214:2010-03 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) | GS 95006-7-1:2016-03 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) | GS 95006-7-1:2021-11 (E 0.1 z wylaczeniem oceny w paragrafie 6.18.3; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.4) | MBN 10384:2010-11 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) | SAE/USCAR-2:2020-02 (p. 5.1.7, 5.1.8) | SAE/USCAR-2:2022-06 (p. 5.1.7, 5.1.8) | SAE/USCAR-2:2024-12 (p. 5.1.7, 5.1.8) | SAE/USCAR-21:2020-01 (p. 4.2; 4.3) | A 009 000 04 99:2013-07 (p. 3.1; 3.11; 3.12)","categories":["electronics"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d94a","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment","methodology":"Pomiar rezystancji, spadku napięcia i ciągłości obwodu / Measurement of resistance, voltage drop and continuity","parameters":[{"name":"Napięcie","range":"0,01 mV - 100 V"},{"name":"Natężenie","range":"do 250 A"},{"name":"Voltage","range":"0,01 mV - 100 V"},{"name":"Current","range":"up to 3 A (250 A with shunt)"}],"technique":null,"techniques":["Metoda miliwoltowa","Metoda prądowa","Monitorowanie mikro-przerw","Millivolt method","Current method","Micro-interruption monitoring"],"computed":[],"activity":"Pomiar rezystancji, spadku napięcia i ciągłości obwodu / Measurement of resistance, voltage drop and continuity\nZakres:\nNapięcie 0,01 mV - 100 V\nNatężenie do 250 A\nVoltage 0,01 mV - 100 V\nCurrent up to 3 A (250 A with shunt)","reference":"IEC 60512-2-1:2002 | IEC 60512-2-2:2003 | VW 75174:2018-10 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0; P 0.2; P 0.2.1; P 0.2.2; P 14.0) | LV 214:2010-03 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) | GS 95006-7-1:2016-03 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) | GS 95006-7-1:2021-11 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) | MBN 10384:2010-11 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) | SAE/USCAR-2:2020-02 (p. 5.1.9; 5.3.1; 5.3.2) | SAE/USCAR-2:2022-06 (p. 5.1.9, 5.3.1, 5.3.2) | SAE/USCAR-2:2024-12 (p. 5.1.9, 5.3.1, 5.3.2) | SAE/USCAR-21:2020-01 (p. 4.5.2; 4.5.3; 4.5.6) | VW 80302:2013-03 (p. E 0.2.3) | VW 80332:2017-09 (p. E 0.2.3) | VW 80332:2019-01 (p. E 0.2.3) | VW 80332:2021-02 (p. E 0.2.3) | VW 80332:2024-01 (TG 0) | MBN LV 215:2017-08 (p. E 0.2.3) | A 009 000 04 99:2013-07 (p. 3.8) | VW 60307:2019-11 (p.7.2.2)","norm_bases":["IEC 60512-2-1:2002","IEC 60512-2-2:2003","VW 75174:2018-10 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0; P 0.2; P 0.2.1; P 0.2.2; P 14.0)","LV 214:2010-03 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0)","GS 95006-7-1:2016-03 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0)","GS 95006-7-1:2021-11 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0)","MBN 10384:2010-11 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0)","SAE/USCAR-2:2020-02 (p. 5.1.9; 5.3.1; 5.3.2)","SAE/USCAR-2:2022-06 (p. 5.1.9, 5.3.1, 5.3.2)","SAE/USCAR-2:2024-12 (p. 5.1.9, 5.3.1, 5.3.2)","SAE/USCAR-21:2020-01 (p. 4.5.2; 4.5.3; 4.5.6)","VW 80302:2013-03 (p. E 0.2.3)","VW 80332:2017-09 (p. E 0.2.3)","VW 80332:2019-01 (p. E 0.2.3)","VW 80332:2021-02 (p. E 0.2.3)","VW 80332:2024-01 (TG 0)","MBN LV 215:2017-08 (p. E 0.2.3)","A 009 000 04 99:2013-07 (p. 3.8)","VW 60307:2019-11 (p.7.2.2)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment Pomiar rezystancji, spadku napięcia i ciągłości obwodu / Measurement of resistance, voltage drop and continuity\nZakres:\nNapięcie 0,01 mV - 100 V\nNatężenie do 250 A\nVoltage 0,01 mV - 100 V\nCurrent up to 3 A (250 A with shunt) IEC 60512-2-1:2002 | IEC 60512-2-2:2003 | VW 75174:2018-10 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0; P 0.2; P 0.2.1; P 0.2.2; P 14.0) | LV 214:2010-03 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) | GS 95006-7-1:2016-03 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) | GS 95006-7-1:2021-11 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) | MBN 10384:2010-11 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) | SAE/USCAR-2:2020-02 (p. 5.1.9; 5.3.1; 5.3.2) | SAE/USCAR-2:2022-06 (p. 5.1.9, 5.3.1, 5.3.2) | SAE/USCAR-2:2024-12 (p. 5.1.9, 5.3.1, 5.3.2) | SAE/USCAR-21:2020-01 (p. 4.5.2; 4.5.3; 4.5.6) | VW 80302:2013-03 (p. E 0.2.3) | VW 80332:2017-09 (p. E 0.2.3) | VW 80332:2019-01 (p. E 0.2.3) | VW 80332:2021-02 (p. E 0.2.3) | VW 80332:2024-01 (TG 0) | MBN LV 215:2017-08 (p. E 0.2.3) | A 009 000 04 99:2013-07 (p. 3.8) | VW 60307:2019-11 (p.7.2.2) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow / Components of cars’ electric and electronic equipment Pomiar rezystancji, spadku napiecia i ciaglosci obwodu / Measurement of resistance, voltage drop and continuity\nZakres:\nNapiecie 0,01 mV - 100 V\nNatezenie do 250 A\nVoltage 0,01 mV - 100 V\nCurrent up to 3 A (250 A with shunt) IEC 60512-2-1:2002 | IEC 60512-2-2:2003 | VW 75174:2018-10 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0; P 0.2; P 0.2.1; P 0.2.2; P 14.0) | LV 214:2010-03 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) | GS 95006-7-1:2016-03 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) | GS 95006-7-1:2021-11 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) | MBN 10384:2010-11 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) | SAE/USCAR-2:2020-02 (p. 5.1.9; 5.3.1; 5.3.2) | SAE/USCAR-2:2022-06 (p. 5.1.9, 5.3.1, 5.3.2) | SAE/USCAR-2:2024-12 (p. 5.1.9, 5.3.1, 5.3.2) | SAE/USCAR-21:2020-01 (p. 4.5.2; 4.5.3; 4.5.6) | VW 80302:2013-03 (p. E 0.2.3) | VW 80332:2017-09 (p. E 0.2.3) | VW 80332:2019-01 (p. E 0.2.3) | VW 80332:2021-02 (p. E 0.2.3) | VW 80332:2024-01 (TG 0) | MBN LV 215:2017-08 (p. E 0.2.3) | A 009 000 04 99:2013-07 (p. 3.8) | VW 60307:2019-11 (p.7.2.2)","categories":["electronics"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d94b","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment","methodology":"Pomiar rezystancji izolacji i wytrzymałości dielektrycznej / Measurement of insulation resistance and dielectric strength","parameters":[{"name":"Rezystancja","range":"2 kΩ - 998 GΩ"},{"name":"Napięcie","range":"(1 - 2500) V"},{"name":"Rezystancja","range":"2 kΩ - 998 GΩ"},{"name":"Napięcie","range":"(1 - 1000) V"},{"name":"Resistance","range":"2 kΩ - 998 GΩ"},{"name":"Voltage","range":"(1 - 2500) V"},{"name":"Resistance","range":"2 kΩ - 998 GΩ"},{"name":"Voltage","range":"(1 - 1000) V"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar rezystancji izolacji i wytrzymałości dielektrycznej / Measurement of insulation resistance and dielectric strength\nZakres:\nRezystancja 2 kΩ - 998 GΩ\nNapięcie (1 - 2500) V\nRezystancja 2 kΩ - 998 GΩ\nNapięcie (1 - 1000) V\nResistance 2 kΩ - 998 GΩ\nVoltage (1 - 2500) V\nResistance 2 kΩ - 998 GΩ\nVoltage (1 - 1000) V","reference":"IEC 60512-3-1:2002 | IEC 60664-1:2020 (p. 6.8) | ISO 8092-2:2005-12 (4.12) | ISO 8092-2:2023-09 (6.4) | ISO 19072-2:2019-12 (p. 4.10) | VW 75174:2018-10 (p. E 0.3; P 0.3) | LV 214:2010-03 (p. E 0.3) | GS 95006-7-1:2016-03 (p. E 0.3) | GS 95006-7-1:2021-11 (p. E 0.3) | MBN 10384:2010-11 (p. E 0.3) | SAE/USCAR-2:2020-02 (p. 5.5.1) | SAE/USCAR-2:2022-06 (p. 5.5.1) | SAE/USCAR-2:2024-12 (p. 5.5.1) | SAE/USCAR-37:2008-08 (p. 5.5.1; 5.5.2) | VW 80302:2013-03 (p. E 0.3; E 0.4) | VW 80332:2017-09 (p. E 0.3; E 0.4) | VW 80332:2019-01 (p. E 0.3; E 0.4) | VW 80332:2021-02 (p. E 0.3; E 0.4) | VW 80332:2024-01 (TG 0) | A 009 000 04 99:2013-07 (p. 3.10) | MBN LV 215:2017-08 (p. E 0.3; E 0.4)","norm_bases":["IEC 60512-3-1:2002","IEC 60664-1:2020 (p. 6.8)","ISO 8092-2:2005-12 (4.12)","ISO 8092-2:2023-09 (6.4)","ISO 19072-2:2019-12 (p. 4.10)","VW 75174:2018-10 (p. E 0.3; P 0.3)","LV 214:2010-03 (p. E 0.3)","GS 95006-7-1:2016-03 (p. E 0.3)","GS 95006-7-1:2021-11 (p. E 0.3)","MBN 10384:2010-11 (p. E 0.3)","SAE/USCAR-2:2020-02 (p. 5.5.1)","SAE/USCAR-2:2022-06 (p. 5.5.1)","SAE/USCAR-2:2024-12 (p. 5.5.1)","SAE/USCAR-37:2008-08 (p. 5.5.1; 5.5.2)","VW 80302:2013-03 (p. E 0.3; E 0.4)","VW 80332:2017-09 (p. E 0.3; E 0.4)","VW 80332:2019-01 (p. E 0.3; E 0.4)","VW 80332:2021-02 (p. E 0.3; E 0.4)","VW 80332:2024-01 (TG 0)","A 009 000 04 99:2013-07 (p. 3.10)","MBN LV 215:2017-08 (p. E 0.3; E 0.4)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment Pomiar rezystancji izolacji i wytrzymałości dielektrycznej / Measurement of insulation resistance and dielectric strength\nZakres:\nRezystancja 2 kΩ - 998 GΩ\nNapięcie (1 - 2500) V\nRezystancja 2 kΩ - 998 GΩ\nNapięcie (1 - 1000) V\nResistance 2 kΩ - 998 GΩ\nVoltage (1 - 2500) V\nResistance 2 kΩ - 998 GΩ\nVoltage (1 - 1000) V IEC 60512-3-1:2002 | IEC 60664-1:2020 (p. 6.8) | ISO 8092-2:2005-12 (4.12) | ISO 8092-2:2023-09 (6.4) | ISO 19072-2:2019-12 (p. 4.10) | VW 75174:2018-10 (p. E 0.3; P 0.3) | LV 214:2010-03 (p. E 0.3) | GS 95006-7-1:2016-03 (p. E 0.3) | GS 95006-7-1:2021-11 (p. E 0.3) | MBN 10384:2010-11 (p. E 0.3) | SAE/USCAR-2:2020-02 (p. 5.5.1) | SAE/USCAR-2:2022-06 (p. 5.5.1) | SAE/USCAR-2:2024-12 (p. 5.5.1) | SAE/USCAR-37:2008-08 (p. 5.5.1; 5.5.2) | VW 80302:2013-03 (p. E 0.3; E 0.4) | VW 80332:2017-09 (p. E 0.3; E 0.4) | VW 80332:2019-01 (p. E 0.3; E 0.4) | VW 80332:2021-02 (p. E 0.3; E 0.4) | VW 80332:2024-01 (TG 0) | A 009 000 04 99:2013-07 (p. 3.10) | MBN LV 215:2017-08 (p. E 0.3; E 0.4) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow / Components of cars’ electric and electronic equipment Pomiar rezystancji izolacji i wytrzymalosci dielektrycznej / Measurement of insulation resistance and dielectric strength\nZakres:\nRezystancja 2 kΩ - 998 GΩ\nNapiecie (1 - 2500) V\nRezystancja 2 kΩ - 998 GΩ\nNapiecie (1 - 1000) V\nResistance 2 kΩ - 998 GΩ\nVoltage (1 - 2500) V\nResistance 2 kΩ - 998 GΩ\nVoltage (1 - 1000) V IEC 60512-3-1:2002 | IEC 60664-1:2020 (p. 6.8) | ISO 8092-2:2005-12 (4.12) | ISO 8092-2:2023-09 (6.4) | ISO 19072-2:2019-12 (p. 4.10) | VW 75174:2018-10 (p. E 0.3; P 0.3) | LV 214:2010-03 (p. E 0.3) | GS 95006-7-1:2016-03 (p. E 0.3) | GS 95006-7-1:2021-11 (p. E 0.3) | MBN 10384:2010-11 (p. E 0.3) | SAE/USCAR-2:2020-02 (p. 5.5.1) | SAE/USCAR-2:2022-06 (p. 5.5.1) | SAE/USCAR-2:2024-12 (p. 5.5.1) | SAE/USCAR-37:2008-08 (p. 5.5.1; 5.5.2) | VW 80302:2013-03 (p. E 0.3; E 0.4) | VW 80332:2017-09 (p. E 0.3; E 0.4) | VW 80332:2019-01 (p. E 0.3; E 0.4) | VW 80332:2021-02 (p. E 0.3; E 0.4) | VW 80332:2024-01 (TG 0) | A 009 000 04 99:2013-07 (p. 3.10) | MBN LV 215:2017-08 (p. E 0.3; E 0.4)","categories":["construction","electronics"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d94c","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment","methodology":"Pomiar długości / Length measurement","parameters":[{"name":"Zakres","range":"(0,2 - 250) mm"},{"name":"Range","range":"(0,2 - 250) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar długości / Length measurement\nZakres:\nZakres (0,2 - 250) mm\nRange (0,2 - 250) mm","reference":"IEC 60512-1-2:2002 | VW 75174:2018-10 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1; P 1.1; P 1.2; P 5.1; P 14.2; P 4.1) | VW 80332:2024-01 (TG 1, TG 4) | LV 214:2010-03 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) | GS 95006-7-1:2016-03 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) | GS 95006-7-1:2021-11 (p. E 1.1; E 1.2; E 4.1; E 5.1; E 14.2) | MBN 10384:2010-11 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) | A 009 000 04 99:2013-07 (p. 3.2)","norm_bases":["IEC 60512-1-2:2002","VW 75174:2018-10 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1; P 1.1; P 1.2; P 5.1; P 14.2; P 4.1)","VW 80332:2024-01 (TG 1, TG 4)","LV 214:2010-03 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1)","GS 95006-7-1:2016-03 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1)","GS 95006-7-1:2021-11 (p. E 1.1; E 1.2; E 4.1; E 5.1; E 14.2)","MBN 10384:2010-11 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1)","A 009 000 04 99:2013-07 (p. 3.2)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment Pomiar długości / Length measurement\nZakres:\nZakres (0,2 - 250) mm\nRange (0,2 - 250) mm IEC 60512-1-2:2002 | VW 75174:2018-10 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1; P 1.1; P 1.2; P 5.1; P 14.2; P 4.1) | VW 80332:2024-01 (TG 1, TG 4) | LV 214:2010-03 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) | GS 95006-7-1:2016-03 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) | GS 95006-7-1:2021-11 (p. E 1.1; E 1.2; E 4.1; E 5.1; E 14.2) | MBN 10384:2010-11 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) | A 009 000 04 99:2013-07 (p. 3.2) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow / Components of cars’ electric and electronic equipment Pomiar dlugosci / Length measurement\nZakres:\nZakres (0,2 - 250) mm\nRange (0,2 - 250) mm IEC 60512-1-2:2002 | VW 75174:2018-10 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1; P 1.1; P 1.2; P 5.1; P 14.2; P 4.1) | VW 80332:2024-01 (TG 1, TG 4) | LV 214:2010-03 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) | GS 95006-7-1:2016-03 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) | GS 95006-7-1:2021-11 (p. E 1.1; E 1.2; E 4.1; E 5.1; E 14.2) | MBN 10384:2010-11 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) | A 009 000 04 99:2013-07 (p. 3.2)","categories":["electronics"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d94d","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment","methodology":"Weryfikacja oznaczeń na powierzchni terminali i tworzyw sztucznych oraz ocena wizualna / Verification of markings on the surface of terminals and plastics and visual inspection","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Weryfikacja oznaczeń na powierzchni terminali i tworzyw sztucznych oraz ocena wizualna / Verification of markings on the surface of terminals and plastics and visual inspection","reference":"VW 75174:2018-10 (TG 2; TG 3) | VW 80332:2024-01 (TG 2; TG 3) | LV 214:2010-03 (PG 2, PG 3) | GS 95006-7-1:2016-03 (PG 2; PG 3) | GS 95006-7-1:2021-11 (PG 2; PG 3) | MBN 10384:2010-11 (PG 2; PG 3)","norm_bases":["VW 75174:2018-10 (TG 2; TG 3)","VW 80332:2024-01 (TG 2; TG 3)","LV 214:2010-03 (PG 2, PG 3)","GS 95006-7-1:2016-03 (PG 2; PG 3)","GS 95006-7-1:2021-11 (PG 2; PG 3)","MBN 10384:2010-11 (PG 2; PG 3)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment Weryfikacja oznaczeń na powierzchni terminali i tworzyw sztucznych oraz ocena wizualna / Verification of markings on the surface of terminals and plastics and visual inspection VW 75174:2018-10 (TG 2; TG 3) | VW 80332:2024-01 (TG 2; TG 3) | LV 214:2010-03 (PG 2, PG 3) | GS 95006-7-1:2016-03 (PG 2; PG 3) | GS 95006-7-1:2021-11 (PG 2; PG 3) | MBN 10384:2010-11 (PG 2; PG 3) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow / Components of cars’ electric and electronic equipment Weryfikacja oznaczen na powierzchni terminali i tworzyw sztucznych oraz ocena wizualna / Verification of markings on the surface of terminals and plastics and visual inspection VW 75174:2018-10 (TG 2; TG 3) | VW 80332:2024-01 (TG 2; TG 3) | LV 214:2010-03 (PG 2, PG 3) | GS 95006-7-1:2016-03 (PG 2; PG 3) | GS 95006-7-1:2021-11 (PG 2; PG 3) | MBN 10384:2010-11 (PG 2; PG 3)","categories":["electronics","materials"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d94e","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów oraz materiały do ich wytwarzania / Components of cars’ electric and electronic equipment and materials for their manufacturing","methodology":"Pomiar grubości powłoki / Coating thickness measurement","parameters":[],"technique":"Metoda fluorescencji rentgenowskiej / X-ray fluorescence method","techniques":[],"computed":[],"activity":"Pomiar grubości powłoki / Coating thickness measurement\nMetoda fluorescencji rentgenowskiej / X-ray fluorescence method","reference":"EN ISO 3497:2000 | PN-EN ISO 3497:2004","norm_bases":["EN ISO 3497:2000","PN-EN ISO 3497:2004"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów oraz materiały do ich wytwarzania / Components of cars’ electric and electronic equipment and materials for their manufacturing Pomiar grubości powłoki / Coating thickness measurement\nMetoda fluorescencji rentgenowskiej / X-ray fluorescence method EN ISO 3497:2000 | PN-EN ISO 3497:2004 Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow oraz materialy do ich wytwarzania / Components of cars’ electric and electronic equipment and materials for their manufacturing Pomiar grubosci powloki / Coating thickness measurement\nMetoda fluorescencji rentgenowskiej / X-ray fluorescence method EN ISO 3497:2000 | PN-EN ISO 3497:2004","categories":["materials","electronics"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d94f","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów oraz materiały do ich wytwarzania / Components of cars’ electric and electronic equipment and materials for their manufacturing","methodology":"Morfologia powierzchni i mikrostruktura. / Surface morphology and microstructure.","parameters":[],"technique":"Metoda skaningowej mikroskopii elektronowej z jakościową analizą składu chemicznego w mikroobszarach (SEM/EDS) / Scanning electron microscopy with qualitative chemical analysis in microareas (SEM/EDS)","techniques":[],"computed":[],"activity":"Morfologia powierzchni i mikrostruktura. / Surface morphology and microstructure.\nMetoda skaningowej mikroskopii elektronowej z jakościową analizą składu chemicznego w mikroobszarach (SEM/EDS) / Scanning electron microscopy with qualitative chemical analysis in microareas (SEM/EDS)","reference":"EAEP_4-4_PE-TCK_01-01-A62_PL wyd. 3 z dnia 01.04.2026 *","norm_bases":["EAEP_4-4_PE-TCK_01-01-A62_PL wyd. 3 z dnia 01.04.2026 *"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów oraz materiały do ich wytwarzania / Components of cars’ electric and electronic equipment and materials for their manufacturing Morfologia powierzchni i mikrostruktura. / Surface morphology and microstructure.\nMetoda skaningowej mikroskopii elektronowej z jakościową analizą składu chemicznego w mikroobszarach (SEM/EDS) / Scanning electron microscopy with qualitative chemical analysis in microareas (SEM/EDS) EAEP_4-4_PE-TCK_01-01-A62_PL wyd. 3 z dnia 01.04.2026 * Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow oraz materialy do ich wytwarzania / Components of cars’ electric and electronic equipment and materials for their manufacturing Morfologia powierzchni i mikrostruktura. / Surface morphology and microstructure.\nMetoda skaningowej mikroskopii elektronowej z jakosciowa analiza skladu chemicznego w mikroobszarach (SEM/EDS) / Scanning electron microscopy with qualitative chemical analysis in microareas (SEM/EDS) EAEP_4-4_PE-TCK_01-01-A62_PL wyd. 3 z dnia 01.04.2026 *","categories":["materials","electronics"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d950","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment","methodology":"Odporność na działanie temperatur / Temperature resistance","parameters":[{"name":"Zakres","range":"(-40 - 200) °C (± 2 °C)"},{"name":"Zakres","range":"(80 - 200) °C"},{"name":"Range","range":"(-40 -200) °C (± 2 °C)"},{"name":"Range","range":"(80 - 200) °C"}],"technique":null,"techniques":["starzenie w suchym gorącu","aging in dry heat"],"computed":[],"activity":"Odporność na działanie temperatur / Temperature resistance\nZakres:\nZakres (-40 - 200) °C (± 2 °C)\nZakres (80 - 200) °C\nRange (-40 -200) °C (± 2 °C)\nRange (80 - 200) °C","reference":"IEC 60068-2-2:2007 | IEC 60068-2-1:2007 | VW 75174:2018-10 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 31.1; B 28.1; B 20.3; L 5.3; L 19.3; L 20.1; L 20.5; L 21.1; L 31.1; L 28.1; L 20.3) | LV 214:2010-03 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) | GS 95006-7-1:2016-03 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) | GS 95006-7-1:2021-11 (p. B 5.3; B 19.3; B 20.1; B 20.3; B 20.5; B 21.1; B 28.1) | MBN 10384:2010-11 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) | VW 50554 – 2 | SAE/USCAR-2:2020-02 (p. 5.6.3) | SAE/USCAR-2:2022-06 (p. 5.6.3) | SAE/USCAR-2:2024-12 (p. 5.6.3) | VW 80332:2017-09 (PG 21) | VW 80332:2019-01 (PG 21) | VW 80332:2021-02 (PG 21) | VW 80332:2024-01 (TG 20; TG 21) | MBN LV 215:2017-08 (PG 21) | A 009 000 04 99:2013-07 (p. 3.10; B 19.3) | VW 60307:2019-11 (p. 7.2.5)","norm_bases":["IEC 60068-2-2:2007","IEC 60068-2-1:2007","VW 75174:2018-10 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 31.1; B 28.1; B 20.3; L 5.3; L 19.3; L 20.1; L 20.5; L 21.1; L 31.1; L 28.1; L 20.3)","LV 214:2010-03 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3)","GS 95006-7-1:2016-03 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3)","GS 95006-7-1:2021-11 (p. B 5.3; B 19.3; B 20.1; B 20.3; B 20.5; B 21.1; B 28.1)","MBN 10384:2010-11 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3)","VW 50554 – 2","SAE/USCAR-2:2020-02 (p. 5.6.3)","SAE/USCAR-2:2022-06 (p. 5.6.3)","SAE/USCAR-2:2024-12 (p. 5.6.3)","VW 80332:2017-09 (PG 21)","VW 80332:2019-01 (PG 21)","VW 80332:2021-02 (PG 21)","VW 80332:2024-01 (TG 20; TG 21)","MBN LV 215:2017-08 (PG 21)","A 009 000 04 99:2013-07 (p. 3.10; B 19.3)","VW 60307:2019-11 (p. 7.2.5)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment Odporność na działanie temperatur / Temperature resistance\nZakres:\nZakres (-40 - 200) °C (± 2 °C)\nZakres (80 - 200) °C\nRange (-40 -200) °C (± 2 °C)\nRange (80 - 200) °C IEC 60068-2-2:2007 | IEC 60068-2-1:2007 | VW 75174:2018-10 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 31.1; B 28.1; B 20.3; L 5.3; L 19.3; L 20.1; L 20.5; L 21.1; L 31.1; L 28.1; L 20.3) | LV 214:2010-03 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) | GS 95006-7-1:2016-03 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) | GS 95006-7-1:2021-11 (p. B 5.3; B 19.3; B 20.1; B 20.3; B 20.5; B 21.1; B 28.1) | MBN 10384:2010-11 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) | VW 50554 – 2 | SAE/USCAR-2:2020-02 (p. 5.6.3) | SAE/USCAR-2:2022-06 (p. 5.6.3) | SAE/USCAR-2:2024-12 (p. 5.6.3) | VW 80332:2017-09 (PG 21) | VW 80332:2019-01 (PG 21) | VW 80332:2021-02 (PG 21) | VW 80332:2024-01 (TG 20; TG 21) | MBN LV 215:2017-08 (PG 21) | A 009 000 04 99:2013-07 (p. 3.10; B 19.3) | VW 60307:2019-11 (p. 7.2.5) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow / Components of cars’ electric and electronic equipment Odpornosc na dzialanie temperatur / Temperature resistance\nZakres:\nZakres (-40 - 200) °C (± 2 °C)\nZakres (80 - 200) °C\nRange (-40 -200) °C (± 2 °C)\nRange (80 - 200) °C IEC 60068-2-2:2007 | IEC 60068-2-1:2007 | VW 75174:2018-10 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 31.1; B 28.1; B 20.3; L 5.3; L 19.3; L 20.1; L 20.5; L 21.1; L 31.1; L 28.1; L 20.3) | LV 214:2010-03 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) | GS 95006-7-1:2016-03 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) | GS 95006-7-1:2021-11 (p. B 5.3; B 19.3; B 20.1; B 20.3; B 20.5; B 21.1; B 28.1) | MBN 10384:2010-11 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) | VW 50554 – 2 | SAE/USCAR-2:2020-02 (p. 5.6.3) | SAE/USCAR-2:2022-06 (p. 5.6.3) | SAE/USCAR-2:2024-12 (p. 5.6.3) | VW 80332:2017-09 (PG 21) | VW 80332:2019-01 (PG 21) | VW 80332:2021-02 (PG 21) | VW 80332:2024-01 (TG 20; TG 21) | MBN LV 215:2017-08 (PG 21) | A 009 000 04 99:2013-07 (p. 3.10; B 19.3) | VW 60307:2019-11 (p. 7.2.5)","categories":["electronics"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d951","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment","methodology":"Odporność na działanie temperatury i wilgoci / Resistance to temperature and humidity","parameters":[{"name":"Temperatura","range":"(23 - 85) °C"},{"name":"Wilgotność","range":"(50 - 95) % RH"},{"name":"Temperature","range":"(23 - 85) °C"},{"name":"Humidity","range":"(50 - 95) % RH"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na działanie temperatury i wilgoci / Resistance to temperature and humidity\nZakres:\nTemperatura (23 - 85) °C\nWilgotność (50 - 95) % RH\nTemperature (23 - 85) °C\nHumidity (50 - 95) % RH","reference":"IEC 60068-2-30:2005 | IEC 60068-2-78:2012-10 | VW 75174:2018-10 (p. B 15.3; B 19.5; B 20.2; L 15.3; L 19.5; L 20.2) | LV 214:2010-03 (p. B 15.3, B 19.5, B 20.2) | GS 95006-7-1:2016-03 (p. B 15.3, B 19.5, B 20.2) | GS 95006-7-1:2021-11 (p. B 15.3; B 19.5; B 20.2) | MBN 10384:2010-11 (p. B 15.3, B 19.5, B 20.2) | SAE/USCAR-2:2020-02 (p. 5.6.2) | SAE/USCAR-2:2022-06 (p. 5.6.2) | SAE/USCAR-2:2024-12 (p. 5.6.2) | SAE/USCAR-21:2020-01 (p. 4.5.4)","norm_bases":["IEC 60068-2-30:2005","IEC 60068-2-78:2012-10","VW 75174:2018-10 (p. B 15.3; B 19.5; B 20.2; L 15.3; L 19.5; L 20.2)","LV 214:2010-03 (p. B 15.3, B 19.5, B 20.2)","GS 95006-7-1:2016-03 (p. B 15.3, B 19.5, B 20.2)","GS 95006-7-1:2021-11 (p. B 15.3; B 19.5; B 20.2)","MBN 10384:2010-11 (p. B 15.3, B 19.5, B 20.2)","SAE/USCAR-2:2020-02 (p. 5.6.2)","SAE/USCAR-2:2022-06 (p. 5.6.2)","SAE/USCAR-2:2024-12 (p. 5.6.2)","SAE/USCAR-21:2020-01 (p. 4.5.4)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment Odporność na działanie temperatury i wilgoci / Resistance to temperature and humidity\nZakres:\nTemperatura (23 - 85) °C\nWilgotność (50 - 95) % RH\nTemperature (23 - 85) °C\nHumidity (50 - 95) % RH IEC 60068-2-30:2005 | IEC 60068-2-78:2012-10 | VW 75174:2018-10 (p. B 15.3; B 19.5; B 20.2; L 15.3; L 19.5; L 20.2) | LV 214:2010-03 (p. B 15.3, B 19.5, B 20.2) | GS 95006-7-1:2016-03 (p. B 15.3, B 19.5, B 20.2) | GS 95006-7-1:2021-11 (p. B 15.3; B 19.5; B 20.2) | MBN 10384:2010-11 (p. B 15.3, B 19.5, B 20.2) | SAE/USCAR-2:2020-02 (p. 5.6.2) | SAE/USCAR-2:2022-06 (p. 5.6.2) | SAE/USCAR-2:2024-12 (p. 5.6.2) | SAE/USCAR-21:2020-01 (p. 4.5.4) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow / Components of cars’ electric and electronic equipment Odpornosc na dzialanie temperatury i wilgoci / Resistance to temperature and humidity\nZakres:\nTemperatura (23 - 85) °C\nWilgotnosc (50 - 95) % RH\nTemperature (23 - 85) °C\nHumidity (50 - 95) % RH IEC 60068-2-30:2005 | IEC 60068-2-78:2012-10 | VW 75174:2018-10 (p. B 15.3; B 19.5; B 20.2; L 15.3; L 19.5; L 20.2) | LV 214:2010-03 (p. B 15.3, B 19.5, B 20.2) | GS 95006-7-1:2016-03 (p. B 15.3, B 19.5, B 20.2) | GS 95006-7-1:2021-11 (p. B 15.3; B 19.5; B 20.2) | MBN 10384:2010-11 (p. B 15.3, B 19.5, B 20.2) | SAE/USCAR-2:2020-02 (p. 5.6.2) | SAE/USCAR-2:2022-06 (p. 5.6.2) | SAE/USCAR-2:2024-12 (p. 5.6.2) | SAE/USCAR-21:2020-01 (p. 4.5.4)","categories":["electronics"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d952","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment","methodology":"Odporność na cykliczne zmiany temperatury / Resistance to cyclical temperature changes","parameters":[{"name":"Zakres","range":"(-40 - 175) °C (± 2 °C)"},{"name":"Range","range":"(-40 - 175) °C (± 2 °C)"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na cykliczne zmiany temperatury / Resistance to cyclical temperature changes\nZakres:\nZakres (-40 - 175) °C (± 2 °C)\nRange (-40 - 175) °C (± 2 °C)","reference":"IEC 60068-2-14:2009 (Test Na, Nb) | VW 75174:2018-10 (p. B 19.1; B 19.2; L 19.1; L 19.2) | VW 80332:2024-01 (TG 19) | LV 214:2010-03 (p. B 19.1; B 19.2) | GS 95006-7-1:2016-03 (p. B 19.1; B 19.2) | GS 95006-7-1:2021-11 (p. B 19.1; B 19.2) | MBN 10384:2010-11 (p. B 19.1; B 19.2) | SAE/USCAR-2:2020-02 (p. 5.6.1) | SAE/USCAR-2:2022-06 (p. 5.6.1) | SAE/USCAR-2:2024-12 (p. 5.6.1) | SAE/USCAR-21:2020-01 (p. 4.5.5) | A 009 000 04 99:2013-07 (p. 3.10) | VW 60307:2019-11 (p. 7.2.3)","norm_bases":["IEC 60068-2-14:2009 (Test Na, Nb)","VW 75174:2018-10 (p. B 19.1; B 19.2; L 19.1; L 19.2)","VW 80332:2024-01 (TG 19)","LV 214:2010-03 (p. B 19.1; B 19.2)","GS 95006-7-1:2016-03 (p. B 19.1; B 19.2)","GS 95006-7-1:2021-11 (p. B 19.1; B 19.2)","MBN 10384:2010-11 (p. B 19.1; B 19.2)","SAE/USCAR-2:2020-02 (p. 5.6.1)","SAE/USCAR-2:2022-06 (p. 5.6.1)","SAE/USCAR-2:2024-12 (p. 5.6.1)","SAE/USCAR-21:2020-01 (p. 4.5.5)","A 009 000 04 99:2013-07 (p. 3.10)","VW 60307:2019-11 (p. 7.2.3)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment Odporność na cykliczne zmiany temperatury / Resistance to cyclical temperature changes\nZakres:\nZakres (-40 - 175) °C (± 2 °C)\nRange (-40 - 175) °C (± 2 °C) IEC 60068-2-14:2009 (Test Na, Nb) | VW 75174:2018-10 (p. B 19.1; B 19.2; L 19.1; L 19.2) | VW 80332:2024-01 (TG 19) | LV 214:2010-03 (p. B 19.1; B 19.2) | GS 95006-7-1:2016-03 (p. B 19.1; B 19.2) | GS 95006-7-1:2021-11 (p. B 19.1; B 19.2) | MBN 10384:2010-11 (p. B 19.1; B 19.2) | SAE/USCAR-2:2020-02 (p. 5.6.1) | SAE/USCAR-2:2022-06 (p. 5.6.1) | SAE/USCAR-2:2024-12 (p. 5.6.1) | SAE/USCAR-21:2020-01 (p. 4.5.5) | A 009 000 04 99:2013-07 (p. 3.10) | VW 60307:2019-11 (p. 7.2.3) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow / Components of cars’ electric and electronic equipment Odpornosc na cykliczne zmiany temperatury / Resistance to cyclical temperature changes\nZakres:\nZakres (-40 - 175) °C (± 2 °C)\nRange (-40 - 175) °C (± 2 °C) IEC 60068-2-14:2009 (Test Na, Nb) | VW 75174:2018-10 (p. B 19.1; B 19.2; L 19.1; L 19.2) | VW 80332:2024-01 (TG 19) | LV 214:2010-03 (p. B 19.1; B 19.2) | GS 95006-7-1:2016-03 (p. B 19.1; B 19.2) | GS 95006-7-1:2021-11 (p. B 19.1; B 19.2) | MBN 10384:2010-11 (p. B 19.1; B 19.2) | SAE/USCAR-2:2020-02 (p. 5.6.1) | SAE/USCAR-2:2022-06 (p. 5.6.1) | SAE/USCAR-2:2024-12 (p. 5.6.1) | SAE/USCAR-21:2020-01 (p. 4.5.5) | A 009 000 04 99:2013-07 (p. 3.10) | VW 60307:2019-11 (p. 7.2.3)","categories":["electronics"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d953","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment","methodology":"Odporność na uszkodzenia mechaniczne Test upadku / Resistance to mechanical damage Drop test","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na uszkodzenia mechaniczne Test upadku / Resistance to mechanical damage Drop test","reference":"IEC 60068-2-31:2008 | VW 75174:2018-10 (TG 6) | VW 80332:2024-01 (TG 6) | LV 214:2010-03 (PG 6) | GS 95006-7-1:2016-03 (PG 6) | GS 95006-7-1:2021-11 (PG 6) | MBN 10384:2010-11 (PG 6) | SAE/USCAR-2:2020-02 (p. 5.4.8) | SAE/USCAR-2:2022-06 (p. 5.4.8) | SAE/USCAR-2:2024-12 (p. 5.4.8)","norm_bases":["IEC 60068-2-31:2008","VW 75174:2018-10 (TG 6)","VW 80332:2024-01 (TG 6)","LV 214:2010-03 (PG 6)","GS 95006-7-1:2016-03 (PG 6)","GS 95006-7-1:2021-11 (PG 6)","MBN 10384:2010-11 (PG 6)","SAE/USCAR-2:2020-02 (p. 5.4.8)","SAE/USCAR-2:2022-06 (p. 5.4.8)","SAE/USCAR-2:2024-12 (p. 5.4.8)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment Odporność na uszkodzenia mechaniczne Test upadku / Resistance to mechanical damage Drop test IEC 60068-2-31:2008 | VW 75174:2018-10 (TG 6) | VW 80332:2024-01 (TG 6) | LV 214:2010-03 (PG 6) | GS 95006-7-1:2016-03 (PG 6) | GS 95006-7-1:2021-11 (PG 6) | MBN 10384:2010-11 (PG 6) | SAE/USCAR-2:2020-02 (p. 5.4.8) | SAE/USCAR-2:2022-06 (p. 5.4.8) | SAE/USCAR-2:2024-12 (p. 5.4.8) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow / Components of cars’ electric and electronic equipment Odpornosc na uszkodzenia mechaniczne Test upadku / Resistance to mechanical damage Drop test IEC 60068-2-31:2008 | VW 75174:2018-10 (TG 6) | VW 80332:2024-01 (TG 6) | LV 214:2010-03 (PG 6) | GS 95006-7-1:2016-03 (PG 6) | GS 95006-7-1:2021-11 (PG 6) | MBN 10384:2010-11 (PG 6) | SAE/USCAR-2:2020-02 (p. 5.4.8) | SAE/USCAR-2:2022-06 (p. 5.4.8) | SAE/USCAR-2:2024-12 (p. 5.4.8)","categories":["electronics"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d954","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment","methodology":"Badania mechaniczne na złączach elektrycznych. Siła: zrywania, wyrywania, wciskania/wkładania i wyjmowania, wypychania; otwierania i zamykania, łączenia i rozłączania, włączania i wyłączania, utrzymania, polaryzacji, kodowania, manewrowania. rozrywania pod kątem prostym rozrywania osiowego / Mechanical tests on electrical connectors. Force: breaking up pulling pressing in / inserting and removing opening and closing connecting and disconnecting switching on and off maintenance polarization coding maneuvering","parameters":[{"name":"Zakres","range":"0,1 N - 20 kN"},{"name":"Zakres","range":"0,1 N - 3 kN (dotyczy obiektów do badań typu zgrzewy USW)"},{"name":"Range","range":"0,1 N to 20 kN"},{"name":"Range","range":"0,1 N to 3 kN (applies to objects for testing the type of USW splices)"}],"technique":null,"techniques":[],"computed":[],"activity":"Badania mechaniczne na złączach elektrycznych. Siła: zrywania, wyrywania, wciskania/wkładania i wyjmowania, wypychania; otwierania i zamykania, łączenia i rozłączania, włączania i wyłączania, utrzymania, polaryzacji, kodowania, manewrowania. rozrywania pod kątem prostym rozrywania osiowego / Mechanical tests on electrical connectors. Force: breaking up pulling pressing in / inserting and removing opening and closing connecting and disconnecting switching on and off maintenance polarization coding maneuvering\nZakres:\nZakres 0,1 N - 20 kN\nZakres 0,1 N - 3 kN (dotyczy obiektów do badań typu zgrzewy USW)\nRange 0,1 N to 20 kN\nRange 0,1 N to 3 kN (applies to objects for testing the type of USW splices)","reference":"IEC 60512-13-5:2006 | IEC 60512-15-6:2008 | ISO 8092-2:2005-12-01 (p. 4.3) | ISO 8092-2:2023:2023-09 (p. 5.1, 5.2, 5.4) | ISO 19072-2:2019-12 (p. 4.3; 4.4) | ISO 19072-2:2007-10-01 (p. 4.3; 4.4) | VW 75174: 2018-10 (E 6.4; P 6.4; TG 7, TG 8, TG 10, TG 11, TG 31) | LV 214:2010-03 (E 6.4; PG 7, PG 8, PG 10, PG 11) | GS 95006-7-1:2016-03 (E 6.4; PG 7, PG 8, PG 10, PG 11) | GS 95006-7-1:2021-11 (E 6.4; PG 7, PG 8, PG 10, PG 11) | MBN 10384:2010-11 (E 6.4; PG 7, PG 8, PG 10, PG 11) | SAE/USCAR-2:2020-02 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) | SAE/USCAR-2:2022-06 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) | SAE/USCAR-2:2024-12 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) | SAE/USCAR-21:2020-01 | VW 80332:2017-09 (PG 8; PG 10; PG 11) | VW 80332:2019-01 (PG 8; PG 10; PG 11) | VW 80332:2021-02 (PG 7; PG 8; PG 10; PG 11) | VW 80332:2024-01 (TG 7; TG 8; TG 10; TG 11) | MBN LV 215:2017-08 (PG 8; PG 10; PG 11) | A 009 000 04 99:2013-07 (p. 3.4: E 11s.1; E 11s.2) | VW 60307:2019-11 (p.7.1.2, 7.1.3)","norm_bases":["IEC 60512-13-5:2006","IEC 60512-15-6:2008","ISO 8092-2:2005-12-01 (p. 4.3)","ISO 8092-2:2023:2023-09 (p. 5.1, 5.2, 5.4)","ISO 19072-2:2019-12 (p. 4.3; 4.4)","ISO 19072-2:2007-10-01 (p. 4.3; 4.4)","VW 75174: 2018-10 (E 6.4; P 6.4; TG 7, TG 8, TG 10, TG 11, TG 31)","LV 214:2010-03 (E 6.4; PG 7, PG 8, PG 10, PG 11)","GS 95006-7-1:2016-03 (E 6.4; PG 7, PG 8, PG 10, PG 11)","GS 95006-7-1:2021-11 (E 6.4; PG 7, PG 8, PG 10, PG 11)","MBN 10384:2010-11 (E 6.4; PG 7, PG 8, PG 10, PG 11)","SAE/USCAR-2:2020-02 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1)","SAE/USCAR-2:2022-06 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1)","SAE/USCAR-2:2024-12 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1)","SAE/USCAR-21:2020-01","VW 80332:2017-09 (PG 8; PG 10; PG 11)","VW 80332:2019-01 (PG 8; PG 10; PG 11)","VW 80332:2021-02 (PG 7; PG 8; PG 10; PG 11)","VW 80332:2024-01 (TG 7; TG 8; TG 10; TG 11)","MBN LV 215:2017-08 (PG 8; PG 10; PG 11)","A 009 000 04 99:2013-07 (p. 3.4: E 11s.1; E 11s.2)","VW 60307:2019-11 (p.7.1.2, 7.1.3)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment Badania mechaniczne na złączach elektrycznych. Siła: zrywania, wyrywania, wciskania/wkładania i wyjmowania, wypychania; otwierania i zamykania, łączenia i rozłączania, włączania i wyłączania, utrzymania, polaryzacji, kodowania, manewrowania. rozrywania pod kątem prostym rozrywania osiowego / Mechanical tests on electrical connectors. Force: breaking up pulling pressing in / inserting and removing opening and closing connecting and disconnecting switching on and off maintenance polarization coding maneuvering\nZakres:\nZakres 0,1 N - 20 kN\nZakres 0,1 N - 3 kN (dotyczy obiektów do badań typu zgrzewy USW)\nRange 0,1 N to 20 kN\nRange 0,1 N to 3 kN (applies to objects for testing the type of USW splices) IEC 60512-13-5:2006 | IEC 60512-15-6:2008 | ISO 8092-2:2005-12-01 (p. 4.3) | ISO 8092-2:2023:2023-09 (p. 5.1, 5.2, 5.4) | ISO 19072-2:2019-12 (p. 4.3; 4.4) | ISO 19072-2:2007-10-01 (p. 4.3; 4.4) | VW 75174: 2018-10 (E 6.4; P 6.4; TG 7, TG 8, TG 10, TG 11, TG 31) | LV 214:2010-03 (E 6.4; PG 7, PG 8, PG 10, PG 11) | GS 95006-7-1:2016-03 (E 6.4; PG 7, PG 8, PG 10, PG 11) | GS 95006-7-1:2021-11 (E 6.4; PG 7, PG 8, PG 10, PG 11) | MBN 10384:2010-11 (E 6.4; PG 7, PG 8, PG 10, PG 11) | SAE/USCAR-2:2020-02 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) | SAE/USCAR-2:2022-06 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) | SAE/USCAR-2:2024-12 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) | SAE/USCAR-21:2020-01 | VW 80332:2017-09 (PG 8; PG 10; PG 11) | VW 80332:2019-01 (PG 8; PG 10; PG 11) | VW 80332:2021-02 (PG 7; PG 8; PG 10; PG 11) | VW 80332:2024-01 (TG 7; TG 8; TG 10; TG 11) | MBN LV 215:2017-08 (PG 8; PG 10; PG 11) | A 009 000 04 99:2013-07 (p. 3.4: E 11s.1; E 11s.2) | VW 60307:2019-11 (p.7.1.2, 7.1.3) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow / Components of cars’ electric and electronic equipment Badania mechaniczne na zlaczach elektrycznych. Sila: zrywania, wyrywania, wciskania/wkladania i wyjmowania, wypychania; otwierania i zamykania, laczenia i rozlaczania, wlaczania i wylaczania, utrzymania, polaryzacji, kodowania, manewrowania. rozrywania pod katem prostym rozrywania osiowego / Mechanical tests on electrical connectors. Force: breaking up pulling pressing in / inserting and removing opening and closing connecting and disconnecting switching on and off maintenance polarization coding maneuvering\nZakres:\nZakres 0,1 N - 20 kN\nZakres 0,1 N - 3 kN (dotyczy obiektow do badan typu zgrzewy USW)\nRange 0,1 N to 20 kN\nRange 0,1 N to 3 kN (applies to objects for testing the type of USW splices) IEC 60512-13-5:2006 | IEC 60512-15-6:2008 | ISO 8092-2:2005-12-01 (p. 4.3) | ISO 8092-2:2023:2023-09 (p. 5.1, 5.2, 5.4) | ISO 19072-2:2019-12 (p. 4.3; 4.4) | ISO 19072-2:2007-10-01 (p. 4.3; 4.4) | VW 75174: 2018-10 (E 6.4; P 6.4; TG 7, TG 8, TG 10, TG 11, TG 31) | LV 214:2010-03 (E 6.4; PG 7, PG 8, PG 10, PG 11) | GS 95006-7-1:2016-03 (E 6.4; PG 7, PG 8, PG 10, PG 11) | GS 95006-7-1:2021-11 (E 6.4; PG 7, PG 8, PG 10, PG 11) | MBN 10384:2010-11 (E 6.4; PG 7, PG 8, PG 10, PG 11) | SAE/USCAR-2:2020-02 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) | SAE/USCAR-2:2022-06 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) | SAE/USCAR-2:2024-12 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) | SAE/USCAR-21:2020-01 | VW 80332:2017-09 (PG 8; PG 10; PG 11) | VW 80332:2019-01 (PG 8; PG 10; PG 11) | VW 80332:2021-02 (PG 7; PG 8; PG 10; PG 11) | VW 80332:2024-01 (TG 7; TG 8; TG 10; TG 11) | MBN LV 215:2017-08 (PG 8; PG 10; PG 11) | A 009 000 04 99:2013-07 (p. 3.4: E 11s.1; E 11s.2) | VW 60307:2019-11 (p.7.1.2, 7.1.3)","categories":["electronics"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d955","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment","methodology":"Badanie obciążalności prądowej / Current carrying capacity test","parameters":[{"name":"Natężenie prądu","range":"do 1000 A"},{"name":"Temperatura obiektu","range":"do 200°C"},{"name":"Current","range":"up to 1000 A"},{"name":"Object temperature","range":"up to 200 °C"}],"technique":null,"techniques":["Przyrost temperatury w funkcji natężenia prądu","Obciążalność prądowa w funkcji temperatury","Termiczna stała czasowa","Temperature increase as a function of current intensity","Current carrying capacity as a function of temperature","Thermal time constant"],"computed":[],"activity":"Badanie obciążalności prądowej / Current carrying capacity test\nZakres:\nNatężenie prądu do 1000 A\nTemperatura obiektu do 200°C\nCurrent up to 1000 A\nObject temperature up to 200 °C","reference":"IEC 60512-5-1:2002 | IEC 60512-5-2:2002 | VW 75174:2018-10 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1; P 12.1; P 13.1; P 12.2; P 13.2; P 14.1) | LV 214:2010-03 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) | GS 95006-7-1:2016-03, (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) | GS 95006-7-1:2021-11 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) | MBN 10384:2010-11 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) | SAE/USCAR-2:2020-02 (p. 5.3.3) | SAE/USCAR-2:2022-06 (p. 5.3.3) | SAE/USCAR-2:2024-12 (p. 5.3.3) | VW 80332:2017-09 (PG 12; PG 13; PG 14) | VW 80332:2019-01 (PG 12; PG 13; PG 14) | VW 80332:2021-02 (PG 12; PG 13; PG 14) | VW 80332:2024-01 (TG 12; TG 13; TG 14) | MBN LV 215:2017-08 (PG 12; PG 13; PG 14)","norm_bases":["IEC 60512-5-1:2002","IEC 60512-5-2:2002","VW 75174:2018-10 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1; P 12.1; P 13.1; P 12.2; P 13.2; P 14.1)","LV 214:2010-03 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1)","GS 95006-7-1:2016-03, (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1)","GS 95006-7-1:2021-11 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1)","MBN 10384:2010-11 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1)","SAE/USCAR-2:2020-02 (p. 5.3.3)","SAE/USCAR-2:2022-06 (p. 5.3.3)","SAE/USCAR-2:2024-12 (p. 5.3.3)","VW 80332:2017-09 (PG 12; PG 13; PG 14)","VW 80332:2019-01 (PG 12; PG 13; PG 14)","VW 80332:2021-02 (PG 12; PG 13; PG 14)","VW 80332:2024-01 (TG 12; TG 13; TG 14)","MBN LV 215:2017-08 (PG 12; PG 13; PG 14)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment Badanie obciążalności prądowej / Current carrying capacity test\nZakres:\nNatężenie prądu do 1000 A\nTemperatura obiektu do 200°C\nCurrent up to 1000 A\nObject temperature up to 200 °C IEC 60512-5-1:2002 | IEC 60512-5-2:2002 | VW 75174:2018-10 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1; P 12.1; P 13.1; P 12.2; P 13.2; P 14.1) | LV 214:2010-03 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) | GS 95006-7-1:2016-03, (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) | GS 95006-7-1:2021-11 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) | MBN 10384:2010-11 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) | SAE/USCAR-2:2020-02 (p. 5.3.3) | SAE/USCAR-2:2022-06 (p. 5.3.3) | SAE/USCAR-2:2024-12 (p. 5.3.3) | VW 80332:2017-09 (PG 12; PG 13; PG 14) | VW 80332:2019-01 (PG 12; PG 13; PG 14) | VW 80332:2021-02 (PG 12; PG 13; PG 14) | VW 80332:2024-01 (TG 12; TG 13; TG 14) | MBN LV 215:2017-08 (PG 12; PG 13; PG 14) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow / Components of cars’ electric and electronic equipment Badanie obciazalnosci pradowej / Current carrying capacity test\nZakres:\nNatezenie pradu do 1000 A\nTemperatura obiektu do 200°C\nCurrent up to 1000 A\nObject temperature up to 200 °C IEC 60512-5-1:2002 | IEC 60512-5-2:2002 | VW 75174:2018-10 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1; P 12.1; P 13.1; P 12.2; P 13.2; P 14.1) | LV 214:2010-03 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) | GS 95006-7-1:2016-03, (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) | GS 95006-7-1:2021-11 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) | MBN 10384:2010-11 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) | SAE/USCAR-2:2020-02 (p. 5.3.3) | SAE/USCAR-2:2022-06 (p. 5.3.3) | SAE/USCAR-2:2024-12 (p. 5.3.3) | VW 80332:2017-09 (PG 12; PG 13; PG 14) | VW 80332:2019-01 (PG 12; PG 13; PG 14) | VW 80332:2021-02 (PG 12; PG 13; PG 14) | VW 80332:2024-01 (TG 12; TG 13; TG 14) | MBN LV 215:2017-08 (PG 12; PG 13; PG 14)","categories":["electronics"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d956","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment","methodology":"Wytrzymałość temperaturowo-prądowa / Temperature and current endurance","parameters":[{"name":"Temperatura środowiska","range":"(-40 - 175) °C (± 2 °C)"},{"name":"Temperatura obiektu","range":"do 200 °C"},{"name":"Natężenie prądu","range":"do 1000 A"},{"name":"Environment temperature","range":"(-40 - 175) °C ± 2 °C"},{"name":"Object temperature","range":"up to 200 °C"},{"name":"Current","range":"up to 1000 A"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość temperaturowo-prądowa / Temperature and current endurance\nZakres:\nTemperatura środowiska (-40 - 175) °C (± 2 °C)\nTemperatura obiektu do 200 °C\nNatężenie prądu do 1000 A\nEnvironment temperature (-40 - 175) °C ± 2 °C\nObject temperature up to 200 °C\nCurrent up to 1000 A","reference":"VW 75174:2018-10 (p. B 15.2; L 15.2) | LV 214:2010-03 (p. B 15.2) | GS 95006-7-1:2016-03 (p. B 15.2) | GS 95006-7-1:2021-11 (p. B 15.2) | MBN 10384:2010-11 (p. B 15.2) | SAE/USCAR-2:2020-02 (p. 5.3.4) | SAE/USCAR-2:2022-06 (p. 5.3.4) | SAE/USCAR-2:2024-12 (p. 5.3.4) | SAE/USCAR-21:2020-01 (p. 4.5.1) | VW 80332:2017-09 (PG 15) | VW 80332:2019-01 (PG 15) | VW 80332:2021-02 (PG 15) | VW 80332:2024-01 (TG 15) | MBN LV 215:2017-08 (PG 15)","norm_bases":["VW 75174:2018-10 (p. B 15.2; L 15.2)","LV 214:2010-03 (p. B 15.2)","GS 95006-7-1:2016-03 (p. B 15.2)","GS 95006-7-1:2021-11 (p. B 15.2)","MBN 10384:2010-11 (p. B 15.2)","SAE/USCAR-2:2020-02 (p. 5.3.4)","SAE/USCAR-2:2022-06 (p. 5.3.4)","SAE/USCAR-2:2024-12 (p. 5.3.4)","SAE/USCAR-21:2020-01 (p. 4.5.1)","VW 80332:2017-09 (PG 15)","VW 80332:2019-01 (PG 15)","VW 80332:2021-02 (PG 15)","VW 80332:2024-01 (TG 15)","MBN LV 215:2017-08 (PG 15)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment Wytrzymałość temperaturowo-prądowa / Temperature and current endurance\nZakres:\nTemperatura środowiska (-40 - 175) °C (± 2 °C)\nTemperatura obiektu do 200 °C\nNatężenie prądu do 1000 A\nEnvironment temperature (-40 - 175) °C ± 2 °C\nObject temperature up to 200 °C\nCurrent up to 1000 A VW 75174:2018-10 (p. B 15.2; L 15.2) | LV 214:2010-03 (p. B 15.2) | GS 95006-7-1:2016-03 (p. B 15.2) | GS 95006-7-1:2021-11 (p. B 15.2) | MBN 10384:2010-11 (p. B 15.2) | SAE/USCAR-2:2020-02 (p. 5.3.4) | SAE/USCAR-2:2022-06 (p. 5.3.4) | SAE/USCAR-2:2024-12 (p. 5.3.4) | SAE/USCAR-21:2020-01 (p. 4.5.1) | VW 80332:2017-09 (PG 15) | VW 80332:2019-01 (PG 15) | VW 80332:2021-02 (PG 15) | VW 80332:2024-01 (TG 15) | MBN LV 215:2017-08 (PG 15) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow / Components of cars’ electric and electronic equipment Wytrzymalosc temperaturowo-pradowa / Temperature and current endurance\nZakres:\nTemperatura srodowiska (-40 - 175) °C (± 2 °C)\nTemperatura obiektu do 200 °C\nNatezenie pradu do 1000 A\nEnvironment temperature (-40 - 175) °C ± 2 °C\nObject temperature up to 200 °C\nCurrent up to 1000 A VW 75174:2018-10 (p. B 15.2; L 15.2) | LV 214:2010-03 (p. B 15.2) | GS 95006-7-1:2016-03 (p. B 15.2) | GS 95006-7-1:2021-11 (p. B 15.2) | MBN 10384:2010-11 (p. B 15.2) | SAE/USCAR-2:2020-02 (p. 5.3.4) | SAE/USCAR-2:2022-06 (p. 5.3.4) | SAE/USCAR-2:2024-12 (p. 5.3.4) | SAE/USCAR-21:2020-01 (p. 4.5.1) | VW 80332:2017-09 (PG 15) | VW 80332:2019-01 (PG 15) | VW 80332:2021-02 (PG 15) | VW 80332:2024-01 (TG 15) | MBN LV 215:2017-08 (PG 15)","categories":["electronics"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d957","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment","methodology":"Odporność na środki chemiczne / Resistance to chemicals","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na środki chemiczne / Resistance to chemicals","reference":"VW 75174:2018-10 (p. B 22.1A; B 22.1B; B 24.1; L 22.1A; L 22.1B; L 24.1) | VW 80332:2024-01 (TG 22) | LV 214:2010-03 (p. B 22.1A; B 22.1B; B 24.1) | GS 95006-7-1:2016-03 (p. B 22.1A; B 22.1B; B 24.1) | GS 95006-7-1:2021-11 (p. B 22.1) | MBN 10384:2010-11 (p. B 22.1A; B 22.1B; B 24.1) | SAE/USCAR-2:2020-02 (p. 5.6.4) | SAE/USCAR-2:2022-06 (p. 5.6.4) | SAE/USCAR-2:2024-12 (p. 5.6.4) | MBN LV 215:2017-08 (PG 22B)","norm_bases":["VW 75174:2018-10 (p. B 22.1A; B 22.1B; B 24.1; L 22.1A; L 22.1B; L 24.1)","VW 80332:2024-01 (TG 22)","LV 214:2010-03 (p. B 22.1A; B 22.1B; B 24.1)","GS 95006-7-1:2016-03 (p. B 22.1A; B 22.1B; B 24.1)","GS 95006-7-1:2021-11 (p. B 22.1)","MBN 10384:2010-11 (p. B 22.1A; B 22.1B; B 24.1)","SAE/USCAR-2:2020-02 (p. 5.6.4)","SAE/USCAR-2:2022-06 (p. 5.6.4)","SAE/USCAR-2:2024-12 (p. 5.6.4)","MBN LV 215:2017-08 (PG 22B)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment Odporność na środki chemiczne / Resistance to chemicals VW 75174:2018-10 (p. B 22.1A; B 22.1B; B 24.1; L 22.1A; L 22.1B; L 24.1) | VW 80332:2024-01 (TG 22) | LV 214:2010-03 (p. B 22.1A; B 22.1B; B 24.1) | GS 95006-7-1:2016-03 (p. B 22.1A; B 22.1B; B 24.1) | GS 95006-7-1:2021-11 (p. B 22.1) | MBN 10384:2010-11 (p. B 22.1A; B 22.1B; B 24.1) | SAE/USCAR-2:2020-02 (p. 5.6.4) | SAE/USCAR-2:2022-06 (p. 5.6.4) | SAE/USCAR-2:2024-12 (p. 5.6.4) | MBN LV 215:2017-08 (PG 22B) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow / Components of cars’ electric and electronic equipment Odpornosc na srodki chemiczne / Resistance to chemicals VW 75174:2018-10 (p. B 22.1A; B 22.1B; B 24.1; L 22.1A; L 22.1B; L 24.1) | VW 80332:2024-01 (TG 22) | LV 214:2010-03 (p. B 22.1A; B 22.1B; B 24.1) | GS 95006-7-1:2016-03 (p. B 22.1A; B 22.1B; B 24.1) | GS 95006-7-1:2021-11 (p. B 22.1) | MBN 10384:2010-11 (p. B 22.1A; B 22.1B; B 24.1) | SAE/USCAR-2:2020-02 (p. 5.6.4) | SAE/USCAR-2:2022-06 (p. 5.6.4) | SAE/USCAR-2:2024-12 (p. 5.6.4) | MBN LV 215:2017-08 (PG 22B)","categories":["electronics"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d958","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment","methodology":"Badanie szczelności / zanurzenie przy różnicy ciśnień / Leak test / immersion with differential pressure","parameters":[{"name":"Ciśnienie","range":"0 - 1 bar (± 0,001 bar)"},{"name":"Ciśnienie","range":"1 - 10 bar (± 0,01 bar)"},{"name":"Pressure","range":"(0 - 1) bar ± 0,001 bar"},{"name":"Pressure","range":"(1 - 10) bar ± 0,01 bar"}],"technique":null,"techniques":[],"computed":[],"activity":"Badanie szczelności / zanurzenie przy różnicy ciśnień / Leak test / immersion with differential pressure\nZakres:\nCiśnienie 0 - 1 bar (± 0,001 bar)\nCiśnienie 1 - 10 bar (± 0,01 bar)\nPressure (0 - 1) bar ± 0,001 bar\nPressure (1 - 10) bar ± 0,01 bar","reference":"IEC 60512-14-5:2006 | IEC 60068-2-13:1983 | VW 75174:2018-10 (p. B 23.1; L 23.1) | VW 80332:2024-01 (TG 23) | LV 214:2010-03 (p. B 23.1) | GS 95006-7-1:2016-03 (p. B 23.1) | GS 95006-7-1:2021-11 (p. B 23.3) | MBN 10384:2010-11 (p. B 23.1) | SAE/USCAR-2:2020-02 (p. 5.6.6) | SAE/USCAR-2:2022-06 (p. 5.6.6) | SAE/USCAR-2:2024-12 (p. 5.6.6) | A 009 000 04 99:2013-07 (p. 3.10: B 23.k1)","norm_bases":["IEC 60512-14-5:2006","IEC 60068-2-13:1983","VW 75174:2018-10 (p. B 23.1; L 23.1)","VW 80332:2024-01 (TG 23)","LV 214:2010-03 (p. B 23.1)","GS 95006-7-1:2016-03 (p. B 23.1)","GS 95006-7-1:2021-11 (p. B 23.3)","MBN 10384:2010-11 (p. B 23.1)","SAE/USCAR-2:2020-02 (p. 5.6.6)","SAE/USCAR-2:2022-06 (p. 5.6.6)","SAE/USCAR-2:2024-12 (p. 5.6.6)","A 009 000 04 99:2013-07 (p. 3.10: B 23.k1)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment Badanie szczelności / zanurzenie przy różnicy ciśnień / Leak test / immersion with differential pressure\nZakres:\nCiśnienie 0 - 1 bar (± 0,001 bar)\nCiśnienie 1 - 10 bar (± 0,01 bar)\nPressure (0 - 1) bar ± 0,001 bar\nPressure (1 - 10) bar ± 0,01 bar IEC 60512-14-5:2006 | IEC 60068-2-13:1983 | VW 75174:2018-10 (p. B 23.1; L 23.1) | VW 80332:2024-01 (TG 23) | LV 214:2010-03 (p. B 23.1) | GS 95006-7-1:2016-03 (p. B 23.1) | GS 95006-7-1:2021-11 (p. B 23.3) | MBN 10384:2010-11 (p. B 23.1) | SAE/USCAR-2:2020-02 (p. 5.6.6) | SAE/USCAR-2:2022-06 (p. 5.6.6) | SAE/USCAR-2:2024-12 (p. 5.6.6) | A 009 000 04 99:2013-07 (p. 3.10: B 23.k1) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow / Components of cars’ electric and electronic equipment Badanie szczelnosci / zanurzenie przy roznicy cisnien / Leak test / immersion with differential pressure\nZakres:\nCisnienie 0 - 1 bar (± 0,001 bar)\nCisnienie 1 - 10 bar (± 0,01 bar)\nPressure (0 - 1) bar ± 0,001 bar\nPressure (1 - 10) bar ± 0,01 bar IEC 60512-14-5:2006 | IEC 60068-2-13:1983 | VW 75174:2018-10 (p. B 23.1; L 23.1) | VW 80332:2024-01 (TG 23) | LV 214:2010-03 (p. B 23.1) | GS 95006-7-1:2016-03 (p. B 23.1) | GS 95006-7-1:2021-11 (p. B 23.3) | MBN 10384:2010-11 (p. B 23.1) | SAE/USCAR-2:2020-02 (p. 5.6.6) | SAE/USCAR-2:2022-06 (p. 5.6.6) | SAE/USCAR-2:2024-12 (p. 5.6.6) | A 009 000 04 99:2013-07 (p. 3.10: B 23.k1)","categories":["electronics"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d959","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment","methodology":"Zanurzenie z szokiem termicznym / Thermal shock immersion","parameters":[{"name":"Temperatura","range":"do 200 °C (± 2 °C)"},{"name":"Temperature","range":"up to 200 °C (± 2 °C)"}],"technique":null,"techniques":[],"computed":[],"activity":"Zanurzenie z szokiem termicznym / Thermal shock immersion\nZakres:\nTemperatura do 200 °C (± 2 °C)\nTemperature up to 200 °C (± 2 °C)","reference":"VW 75174:2018-10 (p. B 23.3; L 23.3) | LV 214:2010-03 (p. B 23.3) | GS 95006-7-1:2016-03 (p. B 23.3) | GS 95006-7-1:2021-11 (p. B 23.5) | MBN 10384:2010-11 (p. B 23.3) | SAE/USCAR-2:2020-02 (p. 5.6.5) | SAE/USCAR-2:2022-06 (p. 5.6.5) | SAE/USCAR-2:2024-12 (p. 5.6.5)","norm_bases":["VW 75174:2018-10 (p. B 23.3; L 23.3)","LV 214:2010-03 (p. B 23.3)","GS 95006-7-1:2016-03 (p. B 23.3)","GS 95006-7-1:2021-11 (p. B 23.5)","MBN 10384:2010-11 (p. B 23.3)","SAE/USCAR-2:2020-02 (p. 5.6.5)","SAE/USCAR-2:2022-06 (p. 5.6.5)","SAE/USCAR-2:2024-12 (p. 5.6.5)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment Zanurzenie z szokiem termicznym / Thermal shock immersion\nZakres:\nTemperatura do 200 °C (± 2 °C)\nTemperature up to 200 °C (± 2 °C) VW 75174:2018-10 (p. B 23.3; L 23.3) | LV 214:2010-03 (p. B 23.3) | GS 95006-7-1:2016-03 (p. B 23.3) | GS 95006-7-1:2021-11 (p. B 23.5) | MBN 10384:2010-11 (p. B 23.3) | SAE/USCAR-2:2020-02 (p. 5.6.5) | SAE/USCAR-2:2022-06 (p. 5.6.5) | SAE/USCAR-2:2024-12 (p. 5.6.5) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow / Components of cars’ electric and electronic equipment Zanurzenie z szokiem termicznym / Thermal shock immersion\nZakres:\nTemperatura do 200 °C (± 2 °C)\nTemperature up to 200 °C (± 2 °C) VW 75174:2018-10 (p. B 23.3; L 23.3) | LV 214:2010-03 (p. B 23.3) | GS 95006-7-1:2016-03 (p. B 23.3) | GS 95006-7-1:2021-11 (p. B 23.5) | MBN 10384:2010-11 (p. B 23.3) | SAE/USCAR-2:2020-02 (p. 5.6.5) | SAE/USCAR-2:2022-06 (p. 5.6.5) | SAE/USCAR-2:2024-12 (p. 5.6.5)","categories":["electronics"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d95a","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment","methodology":"Badanie szczelności / ochrona przed dostępem wody / Leak test / water protection","parameters":[{"name":"Stopień ochrony","range":"IPX4, IPX4K, IPX9K, IPX6, IPX6K"},{"name":"IP code","range":"IPX4, IPX4K, IPX9K, IPX6, IPX6K method"}],"technique":null,"techniques":[],"computed":[],"activity":"Badanie szczelności / ochrona przed dostępem wody / Leak test / water protection\nZakres:\nStopień ochrony IPX4, IPX4K, IPX9K, IPX6, IPX6K\nIP code IPX4, IPX4K, IPX9K, IPX6, IPX6K method","reference":"ISO 20653:2013 | ISO 20653:2023 | VW 75174:2018-10 (p. B 23.4; L 23.4) | LV 214:2010-03 (p. B 23.4) | GS 95006-7-1:2016-03 (p. B 23.4) | GS 95006-7-1:2021-11 (p. B 23.8, B 23.6 ) | MBN 10384:2010-11 (p. B 23.4) | SAE/USCAR-2:2020-02 (p. 5.6.7) | SAE/USCAR-2:2022-06 (p. 5.6.7) | SAE/USCAR-2:2024-12 (p. 5.6.7)","norm_bases":["ISO 20653:2013","ISO 20653:2023","VW 75174:2018-10 (p. B 23.4; L 23.4)","LV 214:2010-03 (p. B 23.4)","GS 95006-7-1:2016-03 (p. B 23.4)","GS 95006-7-1:2021-11 (p. B 23.8, B 23.6 )","MBN 10384:2010-11 (p. B 23.4)","SAE/USCAR-2:2020-02 (p. 5.6.7)","SAE/USCAR-2:2022-06 (p. 5.6.7)","SAE/USCAR-2:2024-12 (p. 5.6.7)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment Badanie szczelności / ochrona przed dostępem wody / Leak test / water protection\nZakres:\nStopień ochrony IPX4, IPX4K, IPX9K, IPX6, IPX6K\nIP code IPX4, IPX4K, IPX9K, IPX6, IPX6K method ISO 20653:2013 | ISO 20653:2023 | VW 75174:2018-10 (p. B 23.4; L 23.4) | LV 214:2010-03 (p. B 23.4) | GS 95006-7-1:2016-03 (p. B 23.4) | GS 95006-7-1:2021-11 (p. B 23.8, B 23.6 ) | MBN 10384:2010-11 (p. B 23.4) | SAE/USCAR-2:2020-02 (p. 5.6.7) | SAE/USCAR-2:2022-06 (p. 5.6.7) | SAE/USCAR-2:2024-12 (p. 5.6.7) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow / Components of cars’ electric and electronic equipment Badanie szczelnosci / ochrona przed dostepem wody / Leak test / water protection\nZakres:\nStopien ochrony IPX4, IPX4K, IPX9K, IPX6, IPX6K\nIP code IPX4, IPX4K, IPX9K, IPX6, IPX6K method ISO 20653:2013 | ISO 20653:2023 | VW 75174:2018-10 (p. B 23.4; L 23.4) | LV 214:2010-03 (p. B 23.4) | GS 95006-7-1:2016-03 (p. B 23.4) | GS 95006-7-1:2021-11 (p. B 23.8, B 23.6 ) | MBN 10384:2010-11 (p. B 23.4) | SAE/USCAR-2:2020-02 (p. 5.6.7) | SAE/USCAR-2:2022-06 (p. 5.6.7) | SAE/USCAR-2:2024-12 (p. 5.6.7)","categories":["water","electronics"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d95b","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment","methodology":"Badanie odporności na jednostajne zginanie (SMBT) / Bending Test (SMBT)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie odporności na jednostajne zginanie (SMBT) / Bending Test (SMBT)","reference":"VW 75174-2:2020-02 (SMBT) | VW 60330:2013-12 (p. 5.1.1) | GS 95006-7-2:2008-03 | MBN 10384-2:2007-12","norm_bases":["VW 75174-2:2020-02 (SMBT)","VW 60330:2013-12 (p. 5.1.1)","GS 95006-7-2:2008-03","MBN 10384-2:2007-12"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów / Components of cars’ electric and electronic equipment Badanie odporności na jednostajne zginanie (SMBT) / Bending Test (SMBT) VW 75174-2:2020-02 (SMBT) | VW 60330:2013-12 (p. 5.1.1) | GS 95006-7-2:2008-03 | MBN 10384-2:2007-12 Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow / Components of cars’ electric and electronic equipment Badanie odpornosci na jednostajne zginanie (SMBT) / Bending Test (SMBT) VW 75174-2:2020-02 (SMBT) | VW 60330:2013-12 (p. 5.1.1) | GS 95006-7-2:2008-03 | MBN 10384-2:2007-12","categories":["electronics"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d95c","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Średnica zewnętrzna kabla / powłoki / Cable outside diameter","parameters":[{"name":"Zakres","range":"0,01 mm do 40 mm"},{"name":"Range","range":"0,01 mm to 40 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Średnica zewnętrzna kabla / powłoki / Cable outside diameter\nZakres:\nZakres 0,01 mm do 40 mm\nRange 0,01 mm to 40 mm","reference":"ISO 19642-2:2019-01 (p. 5.1.2; 6.1.1) | ISO 19642-2:2023 (p. 5.2.1, 6.2.1) | ISO 19642-3:2019-01 (p. 5.2.1) | ISO 19642-4:2019-01 (p. 5.2.1) | ISO 19642-5:2019-01 (p. 5.2.1) | ISO 19642-6:2019-01 (p. 5.2.1) | ISO 19642-7:2019-01 (p. 6.2.1) | ISO 19642-8:2019-01 (p. 6.2.1) | ISO 19642-9:2019-01 (p. 6.2.1) | ISO 19642-10:2019-01 (p. 6.2.1) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.1) | ISO 6722-2:2013-12-01 (p. 5.1) | ISO 14572:2011-10 (p. 5.1) | LV 112-1:2013-04 (p. 9.1.1) | LV 112-1:2014-04 (p. 9.1.1) | LV 112-2:2007-11 (p. 8.1) | LV 112-2:2013-04 (p. 9.1.1) | VW 60306-1:2018-09-01 (p. 9.1.1) | VW 60306-1:2021-10 (p. 9.2.2) | VW 60306-2:2013-04 (p. 9.1.1) | VW 60306-2:2021-11 (p. 9.2.2) | VW 60306-4:2021-12 (p. 9.2.2) | MBN LV 112-1:2016-03 (p. 9.1.1) | MBN 50112-1:2023-06 (p. 12.1.2) | MBN LV 112-2:2012-01 (p. 8.1) | MBN 50112-2: 2023-05 (p. 12.1) | MBN 50112-4: 2024-06 (p. 12.1.2) | GS 95007-1-1:2013-05 (p. 9.1.1) | GS 95007-1-2:2013-05 (p. 9.1.1)","norm_bases":["ISO 19642-2:2019-01 (p. 5.1.2; 6.1.1)","ISO 19642-2:2023 (p. 5.2.1, 6.2.1)","ISO 19642-3:2019-01 (p. 5.2.1)","ISO 19642-4:2019-01 (p. 5.2.1)","ISO 19642-5:2019-01 (p. 5.2.1)","ISO 19642-6:2019-01 (p. 5.2.1)","ISO 19642-7:2019-01 (p. 6.2.1)","ISO 19642-8:2019-01 (p. 6.2.1)","ISO 19642-9:2019-01 (p. 6.2.1)","ISO 19642-10:2019-01 (p. 6.2.1)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.1)","ISO 6722-2:2013-12-01 (p. 5.1)","ISO 14572:2011-10 (p. 5.1)","LV 112-1:2013-04 (p. 9.1.1)","LV 112-1:2014-04 (p. 9.1.1)","LV 112-2:2007-11 (p. 8.1)","LV 112-2:2013-04 (p. 9.1.1)","VW 60306-1:2018-09-01 (p. 9.1.1)","VW 60306-1:2021-10 (p. 9.2.2)","VW 60306-2:2013-04 (p. 9.1.1)","VW 60306-2:2021-11 (p. 9.2.2)","VW 60306-4:2021-12 (p. 9.2.2)","MBN LV 112-1:2016-03 (p. 9.1.1)","MBN 50112-1:2023-06 (p. 12.1.2)","MBN LV 112-2:2012-01 (p. 8.1)","MBN 50112-2: 2023-05 (p. 12.1)","MBN 50112-4: 2024-06 (p. 12.1.2)","GS 95007-1-1:2013-05 (p. 9.1.1)","GS 95007-1-2:2013-05 (p. 9.1.1)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Średnica zewnętrzna kabla / powłoki / Cable outside diameter\nZakres:\nZakres 0,01 mm do 40 mm\nRange 0,01 mm to 40 mm ISO 19642-2:2019-01 (p. 5.1.2; 6.1.1) | ISO 19642-2:2023 (p. 5.2.1, 6.2.1) | ISO 19642-3:2019-01 (p. 5.2.1) | ISO 19642-4:2019-01 (p. 5.2.1) | ISO 19642-5:2019-01 (p. 5.2.1) | ISO 19642-6:2019-01 (p. 5.2.1) | ISO 19642-7:2019-01 (p. 6.2.1) | ISO 19642-8:2019-01 (p. 6.2.1) | ISO 19642-9:2019-01 (p. 6.2.1) | ISO 19642-10:2019-01 (p. 6.2.1) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.1) | ISO 6722-2:2013-12-01 (p. 5.1) | ISO 14572:2011-10 (p. 5.1) | LV 112-1:2013-04 (p. 9.1.1) | LV 112-1:2014-04 (p. 9.1.1) | LV 112-2:2007-11 (p. 8.1) | LV 112-2:2013-04 (p. 9.1.1) | VW 60306-1:2018-09-01 (p. 9.1.1) | VW 60306-1:2021-10 (p. 9.2.2) | VW 60306-2:2013-04 (p. 9.1.1) | VW 60306-2:2021-11 (p. 9.2.2) | VW 60306-4:2021-12 (p. 9.2.2) | MBN LV 112-1:2016-03 (p. 9.1.1) | MBN 50112-1:2023-06 (p. 12.1.2) | MBN LV 112-2:2012-01 (p. 8.1) | MBN 50112-2: 2023-05 (p. 12.1) | MBN 50112-4: 2024-06 (p. 12.1.2) | GS 95007-1-1:2013-05 (p. 9.1.1) | GS 95007-1-2:2013-05 (p. 9.1.1) Kable / Cables Srednica zewnetrzna kabla / powloki / Cable outside diameter\nZakres:\nZakres 0,01 mm do 40 mm\nRange 0,01 mm to 40 mm ISO 19642-2:2019-01 (p. 5.1.2; 6.1.1) | ISO 19642-2:2023 (p. 5.2.1, 6.2.1) | ISO 19642-3:2019-01 (p. 5.2.1) | ISO 19642-4:2019-01 (p. 5.2.1) | ISO 19642-5:2019-01 (p. 5.2.1) | ISO 19642-6:2019-01 (p. 5.2.1) | ISO 19642-7:2019-01 (p. 6.2.1) | ISO 19642-8:2019-01 (p. 6.2.1) | ISO 19642-9:2019-01 (p. 6.2.1) | ISO 19642-10:2019-01 (p. 6.2.1) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.1) | ISO 6722-2:2013-12-01 (p. 5.1) | ISO 14572:2011-10 (p. 5.1) | LV 112-1:2013-04 (p. 9.1.1) | LV 112-1:2014-04 (p. 9.1.1) | LV 112-2:2007-11 (p. 8.1) | LV 112-2:2013-04 (p. 9.1.1) | VW 60306-1:2018-09-01 (p. 9.1.1) | VW 60306-1:2021-10 (p. 9.2.2) | VW 60306-2:2013-04 (p. 9.1.1) | VW 60306-2:2021-11 (p. 9.2.2) | VW 60306-4:2021-12 (p. 9.2.2) | MBN LV 112-1:2016-03 (p. 9.1.1) | MBN 50112-1:2023-06 (p. 12.1.2) | MBN LV 112-2:2012-01 (p. 8.1) | MBN 50112-2: 2023-05 (p. 12.1) | MBN 50112-4: 2024-06 (p. 12.1.2) | GS 95007-1-1:2013-05 (p. 9.1.1) | GS 95007-1-2:2013-05 (p. 9.1.1)","categories":["other"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d95d","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Grubość izolacji / powłoki / Insulation thickness","parameters":[{"name":"Zakres","range":"(0,01 - 40) mm"},{"name":"Range","range":"(0,01 - 40) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Grubość izolacji / powłoki / Insulation thickness\nZakres:\nZakres (0,01 - 40) mm\nRange (0,01 - 40) mm","reference":"IEC 60811-201:2012 | IEC 60811-201:2012-03/AMD1:2017-07 | IEC 60811-201:2012-03/AMD2:2023-11 | IEC 60811-202:2012 | IEC 60811-202:2012-03/AMD1:2017-07 | IEC 60811-202:2012-03/AMD2:2023-11 | ISO 19642-2:2019-01 (p. 5.1.3, 6.1.3) | ISO 19642-2:2023 (p. 5.2.2; 6.2.3) | ISO 19642-3:2019-01 (p. 5.2.2) | ISO 19642-4:2019-01 (p. 5.2.2) | ISO 19642-5:2019-01 (p. 5.2.2) | ISO 19642-6:2019-01 (p. 5.2.2) | ISO 19642-7:2019-01 (p. 6.2.3) | ISO 19642-8:2019-01 (p. 6.2.3) | ISO 19642-9:2019-01 (p. 6.2.3) | ISO 19642-10:2019-01 (p. 6.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.2) | ISO 6722-2:2013-12-01 (p. 5.2) | ISO 14572:2011-10 (p. 5.3) | LV 112-1:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) | LV 112-1:2014-04 (p. 9.1.1; 9.1.4; 9.1.5) | LV 112-2:2007-11 (p. 8.1, 8.2.3) | LV 112-2:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) | VW 60306-1:2018-09-01 (p. 9.1.1) | VW 60306-1:2021-10 (p. 9.2.2) | VW 60306-2:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) | VW 60306-2:2021-11 (p. 9.2.2; 9.2.5) | VW 60306-4:2021-12 (p. 9.2.2) | MBN LV 112-1:2016-03 (p. 9.1.1, 9.1.4, 9.1.5) | MBN 50112-1:2023-06 (p. 12.1.2; 12.1.5; 12.1.6) | MBN LV 112-2:2012-01 (p. 8.1, 8.2.3) | MBN 50112-2: 2023-05 (p. 12.1; 12.2.3) | MBN 50112-4: 2024-06 (p. 12.1.2; 12.1.5; 12.1.6) | GS 95007-1-1:2013-05 (p. 9.1.1, 9.1.4, 9.1.5) | GS 95007-1-2:2013-05 (p. 9.1.1, 9.1.4, 9.1.5)","norm_bases":["IEC 60811-201:2012","IEC 60811-201:2012-03/AMD1:2017-07","IEC 60811-201:2012-03/AMD2:2023-11","IEC 60811-202:2012","IEC 60811-202:2012-03/AMD1:2017-07","IEC 60811-202:2012-03/AMD2:2023-11","ISO 19642-2:2019-01 (p. 5.1.3, 6.1.3)","ISO 19642-2:2023 (p. 5.2.2; 6.2.3)","ISO 19642-3:2019-01 (p. 5.2.2)","ISO 19642-4:2019-01 (p. 5.2.2)","ISO 19642-5:2019-01 (p. 5.2.2)","ISO 19642-6:2019-01 (p. 5.2.2)","ISO 19642-7:2019-01 (p. 6.2.3)","ISO 19642-8:2019-01 (p. 6.2.3)","ISO 19642-9:2019-01 (p. 6.2.3)","ISO 19642-10:2019-01 (p. 6.2.3)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.2)","ISO 6722-2:2013-12-01 (p. 5.2)","ISO 14572:2011-10 (p. 5.3)","LV 112-1:2013-04 (p. 9.1.1, 9.1.4, 9.1.5)","LV 112-1:2014-04 (p. 9.1.1; 9.1.4; 9.1.5)","LV 112-2:2007-11 (p. 8.1, 8.2.3)","LV 112-2:2013-04 (p. 9.1.1, 9.1.4, 9.1.5)","VW 60306-1:2018-09-01 (p. 9.1.1)","VW 60306-1:2021-10 (p. 9.2.2)","VW 60306-2:2013-04 (p. 9.1.1, 9.1.4, 9.1.5)","VW 60306-2:2021-11 (p. 9.2.2; 9.2.5)","VW 60306-4:2021-12 (p. 9.2.2)","MBN LV 112-1:2016-03 (p. 9.1.1, 9.1.4, 9.1.5)","MBN 50112-1:2023-06 (p. 12.1.2; 12.1.5; 12.1.6)","MBN LV 112-2:2012-01 (p. 8.1, 8.2.3)","MBN 50112-2: 2023-05 (p. 12.1; 12.2.3)","MBN 50112-4: 2024-06 (p. 12.1.2; 12.1.5; 12.1.6)","GS 95007-1-1:2013-05 (p. 9.1.1, 9.1.4, 9.1.5)","GS 95007-1-2:2013-05 (p. 9.1.1, 9.1.4, 9.1.5)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Grubość izolacji / powłoki / Insulation thickness\nZakres:\nZakres (0,01 - 40) mm\nRange (0,01 - 40) mm IEC 60811-201:2012 | IEC 60811-201:2012-03/AMD1:2017-07 | IEC 60811-201:2012-03/AMD2:2023-11 | IEC 60811-202:2012 | IEC 60811-202:2012-03/AMD1:2017-07 | IEC 60811-202:2012-03/AMD2:2023-11 | ISO 19642-2:2019-01 (p. 5.1.3, 6.1.3) | ISO 19642-2:2023 (p. 5.2.2; 6.2.3) | ISO 19642-3:2019-01 (p. 5.2.2) | ISO 19642-4:2019-01 (p. 5.2.2) | ISO 19642-5:2019-01 (p. 5.2.2) | ISO 19642-6:2019-01 (p. 5.2.2) | ISO 19642-7:2019-01 (p. 6.2.3) | ISO 19642-8:2019-01 (p. 6.2.3) | ISO 19642-9:2019-01 (p. 6.2.3) | ISO 19642-10:2019-01 (p. 6.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.2) | ISO 6722-2:2013-12-01 (p. 5.2) | ISO 14572:2011-10 (p. 5.3) | LV 112-1:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) | LV 112-1:2014-04 (p. 9.1.1; 9.1.4; 9.1.5) | LV 112-2:2007-11 (p. 8.1, 8.2.3) | LV 112-2:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) | VW 60306-1:2018-09-01 (p. 9.1.1) | VW 60306-1:2021-10 (p. 9.2.2) | VW 60306-2:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) | VW 60306-2:2021-11 (p. 9.2.2; 9.2.5) | VW 60306-4:2021-12 (p. 9.2.2) | MBN LV 112-1:2016-03 (p. 9.1.1, 9.1.4, 9.1.5) | MBN 50112-1:2023-06 (p. 12.1.2; 12.1.5; 12.1.6) | MBN LV 112-2:2012-01 (p. 8.1, 8.2.3) | MBN 50112-2: 2023-05 (p. 12.1; 12.2.3) | MBN 50112-4: 2024-06 (p. 12.1.2; 12.1.5; 12.1.6) | GS 95007-1-1:2013-05 (p. 9.1.1, 9.1.4, 9.1.5) | GS 95007-1-2:2013-05 (p. 9.1.1, 9.1.4, 9.1.5) Kable / Cables Grubosc izolacji / powloki / Insulation thickness\nZakres:\nZakres (0,01 - 40) mm\nRange (0,01 - 40) mm IEC 60811-201:2012 | IEC 60811-201:2012-03/AMD1:2017-07 | IEC 60811-201:2012-03/AMD2:2023-11 | IEC 60811-202:2012 | IEC 60811-202:2012-03/AMD1:2017-07 | IEC 60811-202:2012-03/AMD2:2023-11 | ISO 19642-2:2019-01 (p. 5.1.3, 6.1.3) | ISO 19642-2:2023 (p. 5.2.2; 6.2.3) | ISO 19642-3:2019-01 (p. 5.2.2) | ISO 19642-4:2019-01 (p. 5.2.2) | ISO 19642-5:2019-01 (p. 5.2.2) | ISO 19642-6:2019-01 (p. 5.2.2) | ISO 19642-7:2019-01 (p. 6.2.3) | ISO 19642-8:2019-01 (p. 6.2.3) | ISO 19642-9:2019-01 (p. 6.2.3) | ISO 19642-10:2019-01 (p. 6.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.2) | ISO 6722-2:2013-12-01 (p. 5.2) | ISO 14572:2011-10 (p. 5.3) | LV 112-1:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) | LV 112-1:2014-04 (p. 9.1.1; 9.1.4; 9.1.5) | LV 112-2:2007-11 (p. 8.1, 8.2.3) | LV 112-2:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) | VW 60306-1:2018-09-01 (p. 9.1.1) | VW 60306-1:2021-10 (p. 9.2.2) | VW 60306-2:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) | VW 60306-2:2021-11 (p. 9.2.2; 9.2.5) | VW 60306-4:2021-12 (p. 9.2.2) | MBN LV 112-1:2016-03 (p. 9.1.1, 9.1.4, 9.1.5) | MBN 50112-1:2023-06 (p. 12.1.2; 12.1.5; 12.1.6) | MBN LV 112-2:2012-01 (p. 8.1, 8.2.3) | MBN 50112-2: 2023-05 (p. 12.1; 12.2.3) | MBN 50112-4: 2024-06 (p. 12.1.2; 12.1.5; 12.1.6) | GS 95007-1-1:2013-05 (p. 9.1.1, 9.1.4, 9.1.5) | GS 95007-1-2:2013-05 (p. 9.1.1, 9.1.4, 9.1.5)","categories":["construction"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d95e","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Średnica przewodnika / Conductor diameter","parameters":[{"name":"Zakres","range":"(0,01 - 40) mm"},{"name":"Range","range":"(0,01 - 40) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Średnica przewodnika / Conductor diameter\nZakres:\nZakres (0,01 - 40) mm\nRange (0,01 - 40) mm","reference":"ISO 19642-2:2019-01 (p. 5.1.4) | ISO 19642-2:2023 (p. 5.2.3) | ISO 19642-3:2019-01 (p. 5.2.3) | ISO 19642-4:2019-01 (p. 5.2.3) | ISO 19642-5:2019-01 (p. 5.2.3) | ISO 19642-6:2019-01 (p. 5.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.3) | ISO 6722-2:2013-12-01 (p. 5.3.1) | LV 112-1:2013-04 (p. 9.1.2) | LV 112-1:2014-04 (p. 9.1.2) | LV 112-2:2007-11 (p. 8.1) | VW 60306-1:2018-09-01 (p. 9.1.2) | VW 60306-1:2021-10 (p. 9.2.3) | VW 60306-2:2013-04 (p. 9.1.2) | VW 60306-2:2021-11 (p. 9.2.3) | VW 60306-4:2021-12 (p. 9.2.3) | MBN LV 112-1:2016-03 (p. 9.1.2) | MBN 50112-1:2023-06 (p. 12.1.3) | MBN LV 112-2:2012-01 (p. 8.1) | MBN 50112-2: 2023-05 (p. 12.1) | MBN 50112-4: 2024-06 (p. 12.1.3; 12.1.3.1) | GS 95007-1-1:2013-05 (p. 9.1.2)","norm_bases":["ISO 19642-2:2019-01 (p. 5.1.4)","ISO 19642-2:2023 (p. 5.2.3)","ISO 19642-3:2019-01 (p. 5.2.3)","ISO 19642-4:2019-01 (p. 5.2.3)","ISO 19642-5:2019-01 (p. 5.2.3)","ISO 19642-6:2019-01 (p. 5.2.3)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.3)","ISO 6722-2:2013-12-01 (p. 5.3.1)","LV 112-1:2013-04 (p. 9.1.2)","LV 112-1:2014-04 (p. 9.1.2)","LV 112-2:2007-11 (p. 8.1)","VW 60306-1:2018-09-01 (p. 9.1.2)","VW 60306-1:2021-10 (p. 9.2.3)","VW 60306-2:2013-04 (p. 9.1.2)","VW 60306-2:2021-11 (p. 9.2.3)","VW 60306-4:2021-12 (p. 9.2.3)","MBN LV 112-1:2016-03 (p. 9.1.2)","MBN 50112-1:2023-06 (p. 12.1.3)","MBN LV 112-2:2012-01 (p. 8.1)","MBN 50112-2: 2023-05 (p. 12.1)","MBN 50112-4: 2024-06 (p. 12.1.3; 12.1.3.1)","GS 95007-1-1:2013-05 (p. 9.1.2)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Średnica przewodnika / Conductor diameter\nZakres:\nZakres (0,01 - 40) mm\nRange (0,01 - 40) mm ISO 19642-2:2019-01 (p. 5.1.4) | ISO 19642-2:2023 (p. 5.2.3) | ISO 19642-3:2019-01 (p. 5.2.3) | ISO 19642-4:2019-01 (p. 5.2.3) | ISO 19642-5:2019-01 (p. 5.2.3) | ISO 19642-6:2019-01 (p. 5.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.3) | ISO 6722-2:2013-12-01 (p. 5.3.1) | LV 112-1:2013-04 (p. 9.1.2) | LV 112-1:2014-04 (p. 9.1.2) | LV 112-2:2007-11 (p. 8.1) | VW 60306-1:2018-09-01 (p. 9.1.2) | VW 60306-1:2021-10 (p. 9.2.3) | VW 60306-2:2013-04 (p. 9.1.2) | VW 60306-2:2021-11 (p. 9.2.3) | VW 60306-4:2021-12 (p. 9.2.3) | MBN LV 112-1:2016-03 (p. 9.1.2) | MBN 50112-1:2023-06 (p. 12.1.3) | MBN LV 112-2:2012-01 (p. 8.1) | MBN 50112-2: 2023-05 (p. 12.1) | MBN 50112-4: 2024-06 (p. 12.1.3; 12.1.3.1) | GS 95007-1-1:2013-05 (p. 9.1.2) Kable / Cables Srednica przewodnika / Conductor diameter\nZakres:\nZakres (0,01 - 40) mm\nRange (0,01 - 40) mm ISO 19642-2:2019-01 (p. 5.1.4) | ISO 19642-2:2023 (p. 5.2.3) | ISO 19642-3:2019-01 (p. 5.2.3) | ISO 19642-4:2019-01 (p. 5.2.3) | ISO 19642-5:2019-01 (p. 5.2.3) | ISO 19642-6:2019-01 (p. 5.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.3) | ISO 6722-2:2013-12-01 (p. 5.3.1) | LV 112-1:2013-04 (p. 9.1.2) | LV 112-1:2014-04 (p. 9.1.2) | LV 112-2:2007-11 (p. 8.1) | VW 60306-1:2018-09-01 (p. 9.1.2) | VW 60306-1:2021-10 (p. 9.2.3) | VW 60306-2:2013-04 (p. 9.1.2) | VW 60306-2:2021-11 (p. 9.2.3) | VW 60306-4:2021-12 (p. 9.2.3) | MBN LV 112-1:2016-03 (p. 9.1.2) | MBN 50112-1:2023-06 (p. 12.1.3) | MBN LV 112-2:2012-01 (p. 8.1) | MBN 50112-2: 2023-05 (p. 12.1) | MBN 50112-4: 2024-06 (p. 12.1.3; 12.1.3.1) | GS 95007-1-1:2013-05 (p. 9.1.2)","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d95f","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Powierzchnia przekroju / Cross-sectional area (CSA)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Powierzchnia przekroju / Cross-sectional area (CSA)","reference":"ISO 19642-2:2019-01 (p. 5.1.5) | ISO 19642-2:2023 (p. 5.2.4) | ISO 19642-3:2019-01 (p. 5.2.4) | ISO 19642-4:2019-01 (p. 5.2.4) | ISO 19642-5:2019-01 (p. 5.2.4) | ISO 19642-6:2019-01 (p. 5.2.4) | ISO 6722-2:2013-12-01 (p. 5.3.2)","norm_bases":["ISO 19642-2:2019-01 (p. 5.1.5)","ISO 19642-2:2023 (p. 5.2.4)","ISO 19642-3:2019-01 (p. 5.2.4)","ISO 19642-4:2019-01 (p. 5.2.4)","ISO 19642-5:2019-01 (p. 5.2.4)","ISO 19642-6:2019-01 (p. 5.2.4)","ISO 6722-2:2013-12-01 (p. 5.3.2)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Powierzchnia przekroju / Cross-sectional area (CSA) ISO 19642-2:2019-01 (p. 5.1.5) | ISO 19642-2:2023 (p. 5.2.4) | ISO 19642-3:2019-01 (p. 5.2.4) | ISO 19642-4:2019-01 (p. 5.2.4) | ISO 19642-5:2019-01 (p. 5.2.4) | ISO 19642-6:2019-01 (p. 5.2.4) | ISO 6722-2:2013-12-01 (p. 5.3.2) Kable / Cables Powierzchnia przekroju / Cross-sectional area (CSA) ISO 19642-2:2019-01 (p. 5.1.5) | ISO 19642-2:2023 (p. 5.2.4) | ISO 19642-3:2019-01 (p. 5.2.4) | ISO 19642-4:2019-01 (p. 5.2.4) | ISO 19642-5:2019-01 (p. 5.2.4) | ISO 19642-6:2019-01 (p. 5.2.4) | ISO 6722-2:2013-12-01 (p. 5.3.2)","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d960","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Pomiar rezystancji: - przewodnika - ekranu - kabla skręconego / Resistance measurement of: - conductor - screen - twisted cable","parameters":[{"name":"Miliomomierz","range":"10 µΩ do 10 kΩ"},{"name":"Milliohmmeter","range":"10 µΩ to 10 kΩ"}],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar rezystancji: - przewodnika - ekranu - kabla skręconego / Resistance measurement of: - conductor - screen - twisted cable\nZakres:\nMiliomomierz 10 µΩ do 10 kΩ\nMilliohmmeter 10 µΩ to 10 kΩ","reference":"ISO 19642-2:2019-01 (p. 5.2.1; 6.2.3.2) | ISO 19642-2:2023 (p. 5.3.1; 6.3.3.2) | ISO 19642-3:2019-01 (p. 5.3.1) | ISO 19642-4:2019-01 (p. 5.3.1) | ISO 19642-5:2019-01 (p. 5.3.1) | ISO 19642-6:2019-01 (p. 5.3.1) | ISO 19642-7:2019-01 (p. 6.3.3.2) | ISO 19642-8:2019-01 (p. 6.3.3.2) | ISO 19642-9:2019-01 (p. 6.3.3.2) | ISO 19642-10:2019-01 (p. 6.3.3.2) | ISO 6722-1:2011-10-15, corr.1:2012-09-15 (p. 5.4) | ISO 6722-2:2013-12-01 (p. 5.4) | ISO 14572:2011-10 (p. 5.6.2) | LV 112-1:2013-04 (p. 9.1.3) | LV 112-1:2014-04 (p. 9.1.3) | LV 112-2:2007-11 (p. 8.2) | LV 112-2:2013-04 (p. 9.1.3) | LV 122:2015-05 (p. 11.4.1) | LV 122:2016-02 (p. 11.5.1) | VW 75205:2019-11 (p. 11.4.1) | VW 75205:2023-05 (p. 11.4.1) | VW 75205:2024-04 (p. 11.5.1) | VW 60306-1:2018-09-01 (p. 9.1.3) | VW 60306-1:2021-10 (p. 9.2.4) | VW 60306-2:2013-04 (p. 9.1.3) | VW 60306-2:2021-11 (p. 9.2.4) | VW 60306-4:2021-12 (p. 9.2.4) | MBN LV 112-1:2016-03 (p. 9.1.3) | MBN 50112-1:2023-06 (p. 12.1.4) | MBN LV 112-2:2012-01 (p. 8.2) | MBN 50112-2: 2023-05 (p. 12.2) | MBN LV 122:2017-06 (p. 11.5.1) | MBN 50122:2023-07 (p. 13.5.1) | MBN 50112-4:2024-06 (p. 12.1.4) | GS 95007-1-1:2013-05 (p. 9.1.3) | GS 95007-1-2:2013-05 (p. 9.1.3) | GS 95007-1-5:2015-07 (p. 11.4.1)","norm_bases":["ISO 19642-2:2019-01 (p. 5.2.1; 6.2.3.2)","ISO 19642-2:2023 (p. 5.3.1; 6.3.3.2)","ISO 19642-3:2019-01 (p. 5.3.1)","ISO 19642-4:2019-01 (p. 5.3.1)","ISO 19642-5:2019-01 (p. 5.3.1)","ISO 19642-6:2019-01 (p. 5.3.1)","ISO 19642-7:2019-01 (p. 6.3.3.2)","ISO 19642-8:2019-01 (p. 6.3.3.2)","ISO 19642-9:2019-01 (p. 6.3.3.2)","ISO 19642-10:2019-01 (p. 6.3.3.2)","ISO 6722-1:2011-10-15, corr.1:2012-09-15 (p. 5.4)","ISO 6722-2:2013-12-01 (p. 5.4)","ISO 14572:2011-10 (p. 5.6.2)","LV 112-1:2013-04 (p. 9.1.3)","LV 112-1:2014-04 (p. 9.1.3)","LV 112-2:2007-11 (p. 8.2)","LV 112-2:2013-04 (p. 9.1.3)","LV 122:2015-05 (p. 11.4.1)","LV 122:2016-02 (p. 11.5.1)","VW 75205:2019-11 (p. 11.4.1)","VW 75205:2023-05 (p. 11.4.1)","VW 75205:2024-04 (p. 11.5.1)","VW 60306-1:2018-09-01 (p. 9.1.3)","VW 60306-1:2021-10 (p. 9.2.4)","VW 60306-2:2013-04 (p. 9.1.3)","VW 60306-2:2021-11 (p. 9.2.4)","VW 60306-4:2021-12 (p. 9.2.4)","MBN LV 112-1:2016-03 (p. 9.1.3)","MBN 50112-1:2023-06 (p. 12.1.4)","MBN LV 112-2:2012-01 (p. 8.2)","MBN 50112-2: 2023-05 (p. 12.2)","MBN LV 122:2017-06 (p. 11.5.1)","MBN 50122:2023-07 (p. 13.5.1)","MBN 50112-4:2024-06 (p. 12.1.4)","GS 95007-1-1:2013-05 (p. 9.1.3)","GS 95007-1-2:2013-05 (p. 9.1.3)","GS 95007-1-5:2015-07 (p. 11.4.1)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Pomiar rezystancji: - przewodnika - ekranu - kabla skręconego / Resistance measurement of: - conductor - screen - twisted cable\nZakres:\nMiliomomierz 10 µΩ do 10 kΩ\nMilliohmmeter 10 µΩ to 10 kΩ ISO 19642-2:2019-01 (p. 5.2.1; 6.2.3.2) | ISO 19642-2:2023 (p. 5.3.1; 6.3.3.2) | ISO 19642-3:2019-01 (p. 5.3.1) | ISO 19642-4:2019-01 (p. 5.3.1) | ISO 19642-5:2019-01 (p. 5.3.1) | ISO 19642-6:2019-01 (p. 5.3.1) | ISO 19642-7:2019-01 (p. 6.3.3.2) | ISO 19642-8:2019-01 (p. 6.3.3.2) | ISO 19642-9:2019-01 (p. 6.3.3.2) | ISO 19642-10:2019-01 (p. 6.3.3.2) | ISO 6722-1:2011-10-15, corr.1:2012-09-15 (p. 5.4) | ISO 6722-2:2013-12-01 (p. 5.4) | ISO 14572:2011-10 (p. 5.6.2) | LV 112-1:2013-04 (p. 9.1.3) | LV 112-1:2014-04 (p. 9.1.3) | LV 112-2:2007-11 (p. 8.2) | LV 112-2:2013-04 (p. 9.1.3) | LV 122:2015-05 (p. 11.4.1) | LV 122:2016-02 (p. 11.5.1) | VW 75205:2019-11 (p. 11.4.1) | VW 75205:2023-05 (p. 11.4.1) | VW 75205:2024-04 (p. 11.5.1) | VW 60306-1:2018-09-01 (p. 9.1.3) | VW 60306-1:2021-10 (p. 9.2.4) | VW 60306-2:2013-04 (p. 9.1.3) | VW 60306-2:2021-11 (p. 9.2.4) | VW 60306-4:2021-12 (p. 9.2.4) | MBN LV 112-1:2016-03 (p. 9.1.3) | MBN 50112-1:2023-06 (p. 12.1.4) | MBN LV 112-2:2012-01 (p. 8.2) | MBN 50112-2: 2023-05 (p. 12.2) | MBN LV 122:2017-06 (p. 11.5.1) | MBN 50122:2023-07 (p. 13.5.1) | MBN 50112-4:2024-06 (p. 12.1.4) | GS 95007-1-1:2013-05 (p. 9.1.3) | GS 95007-1-2:2013-05 (p. 9.1.3) | GS 95007-1-5:2015-07 (p. 11.4.1) Kable / Cables Pomiar rezystancji: - przewodnika - ekranu - kabla skreconego / Resistance measurement of: - conductor - screen - twisted cable\nZakres:\nMiliomomierz 10 µΩ do 10 kΩ\nMilliohmmeter 10 µΩ to 10 kΩ ISO 19642-2:2019-01 (p. 5.2.1; 6.2.3.2) | ISO 19642-2:2023 (p. 5.3.1; 6.3.3.2) | ISO 19642-3:2019-01 (p. 5.3.1) | ISO 19642-4:2019-01 (p. 5.3.1) | ISO 19642-5:2019-01 (p. 5.3.1) | ISO 19642-6:2019-01 (p. 5.3.1) | ISO 19642-7:2019-01 (p. 6.3.3.2) | ISO 19642-8:2019-01 (p. 6.3.3.2) | ISO 19642-9:2019-01 (p. 6.3.3.2) | ISO 19642-10:2019-01 (p. 6.3.3.2) | ISO 6722-1:2011-10-15, corr.1:2012-09-15 (p. 5.4) | ISO 6722-2:2013-12-01 (p. 5.4) | ISO 14572:2011-10 (p. 5.6.2) | LV 112-1:2013-04 (p. 9.1.3) | LV 112-1:2014-04 (p. 9.1.3) | LV 112-2:2007-11 (p. 8.2) | LV 112-2:2013-04 (p. 9.1.3) | LV 122:2015-05 (p. 11.4.1) | LV 122:2016-02 (p. 11.5.1) | VW 75205:2019-11 (p. 11.4.1) | VW 75205:2023-05 (p. 11.4.1) | VW 75205:2024-04 (p. 11.5.1) | VW 60306-1:2018-09-01 (p. 9.1.3) | VW 60306-1:2021-10 (p. 9.2.4) | VW 60306-2:2013-04 (p. 9.1.3) | VW 60306-2:2021-11 (p. 9.2.4) | VW 60306-4:2021-12 (p. 9.2.4) | MBN LV 112-1:2016-03 (p. 9.1.3) | MBN 50112-1:2023-06 (p. 12.1.4) | MBN LV 112-2:2012-01 (p. 8.2) | MBN 50112-2: 2023-05 (p. 12.2) | MBN LV 122:2017-06 (p. 11.5.1) | MBN 50122:2023-07 (p. 13.5.1) | MBN 50112-4:2024-06 (p. 12.1.4) | GS 95007-1-1:2013-05 (p. 9.1.3) | GS 95007-1-2:2013-05 (p. 9.1.3) | GS 95007-1-5:2015-07 (p. 11.4.1)","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d961","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Wytrzymałość napięciowa (30 minut) / Withstand voltage (30 min)","parameters":[{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Zakres","range":"5 kV do 10 kV A.C. (50 Hz)"},{"name":"Zakres","range":"0,5 kV do 6 kV D.C."},{"name":"Range","range":"0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Range","range":"5 kV do 10 kV A.C. (50 Hz)"},{"name":"Range","range":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość napięciowa (30 minut) / Withstand voltage (30 min)\nZakres:\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 5 kV do 10 kV A.C. (50 Hz)\nZakres 0,5 kV do 6 kV D.C.\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 5 kV do 10 kV A.C. (50 Hz)\nRange 0,5 kV to 6 kV D.C.","reference":"ISO 19642-2:2019-01 (p. 5.2.3) | ISO 19642-2:2023 (p. 5.3.3) | ISO 19642-3:2019-01 (p. 5.3.3) | ISO 19642-4:2019-01 (p. 5.3.3) | ISO 19642-5:2019-01 (p. 5.3.3) | ISO 19642-6:2019-01 (p. 5.3.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.5) | ISO 6722-2 2013-12-01 (p. 5.5) | LV 112-1:2013-04 (p. 9.5.2) | LV 112-1:2014-04 (p. 9.5.2) | LV 112-2:2007-11 (p. 8.6) | LV 112-2:2013-04 (p. 9.5.2) | LV 122:2015-05 (p. 11.4.3) | LV 122:2016-02 (p. 11.5.3) | LV 212-1:2015-01 (p. 9.5.3) | LV 212-2:2015-01 (9.5.2) | LV 212-2:2015-01 (p. 9.5.3) | LV 216-1:2015-07 (p. 9.5.2) | LV 216-2:2017-02 (p. 9.5.2) | VW 60306-1:2018-09-01 (p. 9.5.2) | VW 60306-1:2021-10 (p. 9.6.2) | VW 60306-2:2013-04 (p. 9.5.2) | VW 60306-2:2021-11 (p. 9.6.2) | VW 60306-4:2021-12 (p. 9.6.2) | VW 75205:2019-11 (p. 11.4.3) | VW 75205:2023-05 (p. 11.4.3) | VW 75205:2024-04 (p. 11.5.3) | VW 75209-1:2015-01 (p. 9.5.2) | VW 75209-2:2015-01 (p. 9.5.2) | VW 75209-2:2015-01 (p. 9.5.2) | VW 75209-2:2021-12 (p. 9.6.1) | VW 75210-1:2023-06 (p. 9.6.2) | VW 75210-1:2024-08 (p. 9.6.2) | VW 75210-2:2023-06 (p. 9.6.2) | MBN LV 112-1:2016-03 (p. 9.5.2) | MBN 50112-1:2023-06 (p. 12.5.2) | MBN LV 112-2:2012-01 (p. 8.6) | MBN 50112-2: 2023-05 (p. 12.6) | MBN 50216-1:2023-07 (p. 12.6.2) | MBN LV 122:2017-06 (p. 11.5.3) | MBN 50122:2023-07 (p. 13.5.3) | MBN LV 212-1:2017-08 (p. 9.5.3) | MBN LV 216-2:2017-07 (p. 9.5.2) | MBN 50112-4:2024-06 (p. 12.5.2) | GS 95007-1-1:2013-05 (p. 9.5.2) | GS 95007-1-2:2013-05 (p. 9.5.2) | GS 95007-6-1:2016-03 (p. 9.5.2) | GS 95007-6-2:2017-04 (p. 9.5.2) | GS 95007-1-5:2015-07 (p. 11.4.3) | GS 95007-3-1:2015-08 (p. 9.5.3) | GS 95007-3-2:2015-09 (p. 9.5.2; 9.5.3)","norm_bases":["ISO 19642-2:2019-01 (p. 5.2.3)","ISO 19642-2:2023 (p. 5.3.3)","ISO 19642-3:2019-01 (p. 5.3.3)","ISO 19642-4:2019-01 (p. 5.3.3)","ISO 19642-5:2019-01 (p. 5.3.3)","ISO 19642-6:2019-01 (p. 5.3.3)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.5)","ISO 6722-2 2013-12-01 (p. 5.5)","LV 112-1:2013-04 (p. 9.5.2)","LV 112-1:2014-04 (p. 9.5.2)","LV 112-2:2007-11 (p. 8.6)","LV 112-2:2013-04 (p. 9.5.2)","LV 122:2015-05 (p. 11.4.3)","LV 122:2016-02 (p. 11.5.3)","LV 212-1:2015-01 (p. 9.5.3)","LV 212-2:2015-01 (9.5.2)","LV 212-2:2015-01 (p. 9.5.3)","LV 216-1:2015-07 (p. 9.5.2)","LV 216-2:2017-02 (p. 9.5.2)","VW 60306-1:2018-09-01 (p. 9.5.2)","VW 60306-1:2021-10 (p. 9.6.2)","VW 60306-2:2013-04 (p. 9.5.2)","VW 60306-2:2021-11 (p. 9.6.2)","VW 60306-4:2021-12 (p. 9.6.2)","VW 75205:2019-11 (p. 11.4.3)","VW 75205:2023-05 (p. 11.4.3)","VW 75205:2024-04 (p. 11.5.3)","VW 75209-1:2015-01 (p. 9.5.2)","VW 75209-2:2015-01 (p. 9.5.2)","VW 75209-2:2015-01 (p. 9.5.2)","VW 75209-2:2021-12 (p. 9.6.1)","VW 75210-1:2023-06 (p. 9.6.2)","VW 75210-1:2024-08 (p. 9.6.2)","VW 75210-2:2023-06 (p. 9.6.2)","MBN LV 112-1:2016-03 (p. 9.5.2)","MBN 50112-1:2023-06 (p. 12.5.2)","MBN LV 112-2:2012-01 (p. 8.6)","MBN 50112-2: 2023-05 (p. 12.6)","MBN 50216-1:2023-07 (p. 12.6.2)","MBN LV 122:2017-06 (p. 11.5.3)","MBN 50122:2023-07 (p. 13.5.3)","MBN LV 212-1:2017-08 (p. 9.5.3)","MBN LV 216-2:2017-07 (p. 9.5.2)","MBN 50112-4:2024-06 (p. 12.5.2)","GS 95007-1-1:2013-05 (p. 9.5.2)","GS 95007-1-2:2013-05 (p. 9.5.2)","GS 95007-6-1:2016-03 (p. 9.5.2)","GS 95007-6-2:2017-04 (p. 9.5.2)","GS 95007-1-5:2015-07 (p. 11.4.3)","GS 95007-3-1:2015-08 (p. 9.5.3)","GS 95007-3-2:2015-09 (p. 9.5.2; 9.5.3)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Wytrzymałość napięciowa (30 minut) / Withstand voltage (30 min)\nZakres:\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 5 kV do 10 kV A.C. (50 Hz)\nZakres 0,5 kV do 6 kV D.C.\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 5 kV do 10 kV A.C. (50 Hz)\nRange 0,5 kV to 6 kV D.C. ISO 19642-2:2019-01 (p. 5.2.3) | ISO 19642-2:2023 (p. 5.3.3) | ISO 19642-3:2019-01 (p. 5.3.3) | ISO 19642-4:2019-01 (p. 5.3.3) | ISO 19642-5:2019-01 (p. 5.3.3) | ISO 19642-6:2019-01 (p. 5.3.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.5) | ISO 6722-2 2013-12-01 (p. 5.5) | LV 112-1:2013-04 (p. 9.5.2) | LV 112-1:2014-04 (p. 9.5.2) | LV 112-2:2007-11 (p. 8.6) | LV 112-2:2013-04 (p. 9.5.2) | LV 122:2015-05 (p. 11.4.3) | LV 122:2016-02 (p. 11.5.3) | LV 212-1:2015-01 (p. 9.5.3) | LV 212-2:2015-01 (9.5.2) | LV 212-2:2015-01 (p. 9.5.3) | LV 216-1:2015-07 (p. 9.5.2) | LV 216-2:2017-02 (p. 9.5.2) | VW 60306-1:2018-09-01 (p. 9.5.2) | VW 60306-1:2021-10 (p. 9.6.2) | VW 60306-2:2013-04 (p. 9.5.2) | VW 60306-2:2021-11 (p. 9.6.2) | VW 60306-4:2021-12 (p. 9.6.2) | VW 75205:2019-11 (p. 11.4.3) | VW 75205:2023-05 (p. 11.4.3) | VW 75205:2024-04 (p. 11.5.3) | VW 75209-1:2015-01 (p. 9.5.2) | VW 75209-2:2015-01 (p. 9.5.2) | VW 75209-2:2015-01 (p. 9.5.2) | VW 75209-2:2021-12 (p. 9.6.1) | VW 75210-1:2023-06 (p. 9.6.2) | VW 75210-1:2024-08 (p. 9.6.2) | VW 75210-2:2023-06 (p. 9.6.2) | MBN LV 112-1:2016-03 (p. 9.5.2) | MBN 50112-1:2023-06 (p. 12.5.2) | MBN LV 112-2:2012-01 (p. 8.6) | MBN 50112-2: 2023-05 (p. 12.6) | MBN 50216-1:2023-07 (p. 12.6.2) | MBN LV 122:2017-06 (p. 11.5.3) | MBN 50122:2023-07 (p. 13.5.3) | MBN LV 212-1:2017-08 (p. 9.5.3) | MBN LV 216-2:2017-07 (p. 9.5.2) | MBN 50112-4:2024-06 (p. 12.5.2) | GS 95007-1-1:2013-05 (p. 9.5.2) | GS 95007-1-2:2013-05 (p. 9.5.2) | GS 95007-6-1:2016-03 (p. 9.5.2) | GS 95007-6-2:2017-04 (p. 9.5.2) | GS 95007-1-5:2015-07 (p. 11.4.3) | GS 95007-3-1:2015-08 (p. 9.5.3) | GS 95007-3-2:2015-09 (p. 9.5.2; 9.5.3) Kable / Cables Wytrzymalosc napieciowa (30 minut) / Withstand voltage (30 min)\nZakres:\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 5 kV do 10 kV A.C. (50 Hz)\nZakres 0,5 kV do 6 kV D.C.\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 5 kV do 10 kV A.C. (50 Hz)\nRange 0,5 kV to 6 kV D.C. ISO 19642-2:2019-01 (p. 5.2.3) | ISO 19642-2:2023 (p. 5.3.3) | ISO 19642-3:2019-01 (p. 5.3.3) | ISO 19642-4:2019-01 (p. 5.3.3) | ISO 19642-5:2019-01 (p. 5.3.3) | ISO 19642-6:2019-01 (p. 5.3.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.5) | ISO 6722-2 2013-12-01 (p. 5.5) | LV 112-1:2013-04 (p. 9.5.2) | LV 112-1:2014-04 (p. 9.5.2) | LV 112-2:2007-11 (p. 8.6) | LV 112-2:2013-04 (p. 9.5.2) | LV 122:2015-05 (p. 11.4.3) | LV 122:2016-02 (p. 11.5.3) | LV 212-1:2015-01 (p. 9.5.3) | LV 212-2:2015-01 (9.5.2) | LV 212-2:2015-01 (p. 9.5.3) | LV 216-1:2015-07 (p. 9.5.2) | LV 216-2:2017-02 (p. 9.5.2) | VW 60306-1:2018-09-01 (p. 9.5.2) | VW 60306-1:2021-10 (p. 9.6.2) | VW 60306-2:2013-04 (p. 9.5.2) | VW 60306-2:2021-11 (p. 9.6.2) | VW 60306-4:2021-12 (p. 9.6.2) | VW 75205:2019-11 (p. 11.4.3) | VW 75205:2023-05 (p. 11.4.3) | VW 75205:2024-04 (p. 11.5.3) | VW 75209-1:2015-01 (p. 9.5.2) | VW 75209-2:2015-01 (p. 9.5.2) | VW 75209-2:2015-01 (p. 9.5.2) | VW 75209-2:2021-12 (p. 9.6.1) | VW 75210-1:2023-06 (p. 9.6.2) | VW 75210-1:2024-08 (p. 9.6.2) | VW 75210-2:2023-06 (p. 9.6.2) | MBN LV 112-1:2016-03 (p. 9.5.2) | MBN 50112-1:2023-06 (p. 12.5.2) | MBN LV 112-2:2012-01 (p. 8.6) | MBN 50112-2: 2023-05 (p. 12.6) | MBN 50216-1:2023-07 (p. 12.6.2) | MBN LV 122:2017-06 (p. 11.5.3) | MBN 50122:2023-07 (p. 13.5.3) | MBN LV 212-1:2017-08 (p. 9.5.3) | MBN LV 216-2:2017-07 (p. 9.5.2) | MBN 50112-4:2024-06 (p. 12.5.2) | GS 95007-1-1:2013-05 (p. 9.5.2) | GS 95007-1-2:2013-05 (p. 9.5.2) | GS 95007-6-1:2016-03 (p. 9.5.2) | GS 95007-6-2:2017-04 (p. 9.5.2) | GS 95007-1-5:2015-07 (p. 11.4.3) | GS 95007-3-1:2015-08 (p. 9.5.3) | GS 95007-3-2:2015-09 (p. 9.5.2; 9.5.3)","categories":["other"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d962","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Wytrzymałość napięciowa po testach środowiskowych (1 minuta) / Withstand voltage after environmental testing (1 minute)","parameters":[{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Zakres","range":"5 kV do 10 kV A.C. (50 Hz)"},{"name":"Zakres","range":"0,5 kV do 6 kV D.C."},{"name":"Range","range":"0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Range","range":"5 kV do 10 kV A.C. (50 Hz)"},{"name":"Range","range":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość napięciowa po testach środowiskowych (1 minuta) / Withstand voltage after environmental testing (1 minute)\nZakres:\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 5 kV do 10 kV A.C. (50 Hz)\nZakres 0,5 kV do 6 kV D.C.\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 5 kV do 10 kV A.C. (50 Hz)\nRange 0,5 kV to 6 kV D.C.","reference":"ISO 19642-2:2019-01 (p. 5.2.4; 6.2.2) | ISO 19642-2:2023 (p. 5.3.4; 6.3.2) | ISO 19642-3:2019-01 (p. 5.3.4) | ISO 19642-4:2019-01 (p. 5.3.4) | ISO 19642-5:2019-01 (p. 5.3.4) | ISO 19642-6:2019-01 (p. 5.3.4) | ISO 19642-7:2019-01 (p. 6.3.2) | ISO 19642-8:2019-01 (p. 6.3.2) | ISO 19642-9:2019-01 (p. 6.3.2) | ISO 19642-10:2019-01 (p. 6.3.2) | ISO 14572:2011-10 (p. 5.5) | LV 112-1:2013-04 (p. 9.5.3) | LV 112-1:2014-04 (p. 9.5.3) | LV 112-2:2007-11 (p. 8.6) | LV 112-2:2013-04 (p. 9.5.3) | LV 122:2015-05 (p. 11.4.4) | LV 122:2016-02 (p. 11.5.4) | LV 216-1:2015-07 (p. 9.5.3) | LV 216-2:2017-02 (p. 9.5.3) | VW 60306-1:2018-09-01 (p. 9.5.3) | VW 60306-1:2021-10 (p. 9.6.3) | VW 60306-2:2013-04 (p. 9.5.3) | VW 60306-2:2021-11 (p. 9.6.3) | VW 60306-4:2021-12 (p. 9.6.3) | VW 75209-1:2015-01 (p. 9.5.3) | VW 75209-1:2021-12 (p. 9.6.2) | VW 75209-2:2015-01 (p. 9.5.3) | VW 75209-2:2021-12 (p. 9.6.2) | VW 75210-1:2023-06 (p. 9.6.3) | VW 75210-1:2024-08 (p. 9.6.3) | VW 75210-2:2023-06 (p. 9.6.3) | MBN LV 112-1:2016-03 (p. 9.5.3) | MBN 50112-1:2023-06 (p. 12.5.3) | MBN LV 112-2:2012-01 (p. 8.6) | MBN 50112-2: 2023-05 (p. 12.6) | MBN 50216-1:2023-07 (p. 12.6.3) | MBN LV 122:2017-06 (p. 11.5.4) | MBN 50122:2023-07 (p. 13.5.4) | MBN 50212-1:2023-04 (p. 12.6.3) | MBN LV 216-2:2017-07 (p. 9.5.3) | MBN 50112-4:2024-06 (p. 12.5.3) | GS 95007-1-1:2013-05 (p. 9.5.3) | GS 95007-1-2:2013-05 (p. 9.5.3) | GS 95007-1-5:2015-07 (p. 11.4.4) | GS 95007-6-1:2016-03 (p. 9.5.3) | GS 95007-6-2:2017-04 (p. 9.5.3)","norm_bases":["ISO 19642-2:2019-01 (p. 5.2.4; 6.2.2)","ISO 19642-2:2023 (p. 5.3.4; 6.3.2)","ISO 19642-3:2019-01 (p. 5.3.4)","ISO 19642-4:2019-01 (p. 5.3.4)","ISO 19642-5:2019-01 (p. 5.3.4)","ISO 19642-6:2019-01 (p. 5.3.4)","ISO 19642-7:2019-01 (p. 6.3.2)","ISO 19642-8:2019-01 (p. 6.3.2)","ISO 19642-9:2019-01 (p. 6.3.2)","ISO 19642-10:2019-01 (p. 6.3.2)","ISO 14572:2011-10 (p. 5.5)","LV 112-1:2013-04 (p. 9.5.3)","LV 112-1:2014-04 (p. 9.5.3)","LV 112-2:2007-11 (p. 8.6)","LV 112-2:2013-04 (p. 9.5.3)","LV 122:2015-05 (p. 11.4.4)","LV 122:2016-02 (p. 11.5.4)","LV 216-1:2015-07 (p. 9.5.3)","LV 216-2:2017-02 (p. 9.5.3)","VW 60306-1:2018-09-01 (p. 9.5.3)","VW 60306-1:2021-10 (p. 9.6.3)","VW 60306-2:2013-04 (p. 9.5.3)","VW 60306-2:2021-11 (p. 9.6.3)","VW 60306-4:2021-12 (p. 9.6.3)","VW 75209-1:2015-01 (p. 9.5.3)","VW 75209-1:2021-12 (p. 9.6.2)","VW 75209-2:2015-01 (p. 9.5.3)","VW 75209-2:2021-12 (p. 9.6.2)","VW 75210-1:2023-06 (p. 9.6.3)","VW 75210-1:2024-08 (p. 9.6.3)","VW 75210-2:2023-06 (p. 9.6.3)","MBN LV 112-1:2016-03 (p. 9.5.3)","MBN 50112-1:2023-06 (p. 12.5.3)","MBN LV 112-2:2012-01 (p. 8.6)","MBN 50112-2: 2023-05 (p. 12.6)","MBN 50216-1:2023-07 (p. 12.6.3)","MBN LV 122:2017-06 (p. 11.5.4)","MBN 50122:2023-07 (p. 13.5.4)","MBN 50212-1:2023-04 (p. 12.6.3)","MBN LV 216-2:2017-07 (p. 9.5.3)","MBN 50112-4:2024-06 (p. 12.5.3)","GS 95007-1-1:2013-05 (p. 9.5.3)","GS 95007-1-2:2013-05 (p. 9.5.3)","GS 95007-1-5:2015-07 (p. 11.4.4)","GS 95007-6-1:2016-03 (p. 9.5.3)","GS 95007-6-2:2017-04 (p. 9.5.3)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Wytrzymałość napięciowa po testach środowiskowych (1 minuta) / Withstand voltage after environmental testing (1 minute)\nZakres:\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 5 kV do 10 kV A.C. (50 Hz)\nZakres 0,5 kV do 6 kV D.C.\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 5 kV do 10 kV A.C. (50 Hz)\nRange 0,5 kV to 6 kV D.C. ISO 19642-2:2019-01 (p. 5.2.4; 6.2.2) | ISO 19642-2:2023 (p. 5.3.4; 6.3.2) | ISO 19642-3:2019-01 (p. 5.3.4) | ISO 19642-4:2019-01 (p. 5.3.4) | ISO 19642-5:2019-01 (p. 5.3.4) | ISO 19642-6:2019-01 (p. 5.3.4) | ISO 19642-7:2019-01 (p. 6.3.2) | ISO 19642-8:2019-01 (p. 6.3.2) | ISO 19642-9:2019-01 (p. 6.3.2) | ISO 19642-10:2019-01 (p. 6.3.2) | ISO 14572:2011-10 (p. 5.5) | LV 112-1:2013-04 (p. 9.5.3) | LV 112-1:2014-04 (p. 9.5.3) | LV 112-2:2007-11 (p. 8.6) | LV 112-2:2013-04 (p. 9.5.3) | LV 122:2015-05 (p. 11.4.4) | LV 122:2016-02 (p. 11.5.4) | LV 216-1:2015-07 (p. 9.5.3) | LV 216-2:2017-02 (p. 9.5.3) | VW 60306-1:2018-09-01 (p. 9.5.3) | VW 60306-1:2021-10 (p. 9.6.3) | VW 60306-2:2013-04 (p. 9.5.3) | VW 60306-2:2021-11 (p. 9.6.3) | VW 60306-4:2021-12 (p. 9.6.3) | VW 75209-1:2015-01 (p. 9.5.3) | VW 75209-1:2021-12 (p. 9.6.2) | VW 75209-2:2015-01 (p. 9.5.3) | VW 75209-2:2021-12 (p. 9.6.2) | VW 75210-1:2023-06 (p. 9.6.3) | VW 75210-1:2024-08 (p. 9.6.3) | VW 75210-2:2023-06 (p. 9.6.3) | MBN LV 112-1:2016-03 (p. 9.5.3) | MBN 50112-1:2023-06 (p. 12.5.3) | MBN LV 112-2:2012-01 (p. 8.6) | MBN 50112-2: 2023-05 (p. 12.6) | MBN 50216-1:2023-07 (p. 12.6.3) | MBN LV 122:2017-06 (p. 11.5.4) | MBN 50122:2023-07 (p. 13.5.4) | MBN 50212-1:2023-04 (p. 12.6.3) | MBN LV 216-2:2017-07 (p. 9.5.3) | MBN 50112-4:2024-06 (p. 12.5.3) | GS 95007-1-1:2013-05 (p. 9.5.3) | GS 95007-1-2:2013-05 (p. 9.5.3) | GS 95007-1-5:2015-07 (p. 11.4.4) | GS 95007-6-1:2016-03 (p. 9.5.3) | GS 95007-6-2:2017-04 (p. 9.5.3) Kable / Cables Wytrzymalosc napieciowa po testach srodowiskowych (1 minuta) / Withstand voltage after environmental testing (1 minute)\nZakres:\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 5 kV do 10 kV A.C. (50 Hz)\nZakres 0,5 kV do 6 kV D.C.\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 5 kV do 10 kV A.C. (50 Hz)\nRange 0,5 kV to 6 kV D.C. ISO 19642-2:2019-01 (p. 5.2.4; 6.2.2) | ISO 19642-2:2023 (p. 5.3.4; 6.3.2) | ISO 19642-3:2019-01 (p. 5.3.4) | ISO 19642-4:2019-01 (p. 5.3.4) | ISO 19642-5:2019-01 (p. 5.3.4) | ISO 19642-6:2019-01 (p. 5.3.4) | ISO 19642-7:2019-01 (p. 6.3.2) | ISO 19642-8:2019-01 (p. 6.3.2) | ISO 19642-9:2019-01 (p. 6.3.2) | ISO 19642-10:2019-01 (p. 6.3.2) | ISO 14572:2011-10 (p. 5.5) | LV 112-1:2013-04 (p. 9.5.3) | LV 112-1:2014-04 (p. 9.5.3) | LV 112-2:2007-11 (p. 8.6) | LV 112-2:2013-04 (p. 9.5.3) | LV 122:2015-05 (p. 11.4.4) | LV 122:2016-02 (p. 11.5.4) | LV 216-1:2015-07 (p. 9.5.3) | LV 216-2:2017-02 (p. 9.5.3) | VW 60306-1:2018-09-01 (p. 9.5.3) | VW 60306-1:2021-10 (p. 9.6.3) | VW 60306-2:2013-04 (p. 9.5.3) | VW 60306-2:2021-11 (p. 9.6.3) | VW 60306-4:2021-12 (p. 9.6.3) | VW 75209-1:2015-01 (p. 9.5.3) | VW 75209-1:2021-12 (p. 9.6.2) | VW 75209-2:2015-01 (p. 9.5.3) | VW 75209-2:2021-12 (p. 9.6.2) | VW 75210-1:2023-06 (p. 9.6.3) | VW 75210-1:2024-08 (p. 9.6.3) | VW 75210-2:2023-06 (p. 9.6.3) | MBN LV 112-1:2016-03 (p. 9.5.3) | MBN 50112-1:2023-06 (p. 12.5.3) | MBN LV 112-2:2012-01 (p. 8.6) | MBN 50112-2: 2023-05 (p. 12.6) | MBN 50216-1:2023-07 (p. 12.6.3) | MBN LV 122:2017-06 (p. 11.5.4) | MBN 50122:2023-07 (p. 13.5.4) | MBN 50212-1:2023-04 (p. 12.6.3) | MBN LV 216-2:2017-07 (p. 9.5.3) | MBN 50112-4:2024-06 (p. 12.5.3) | GS 95007-1-1:2013-05 (p. 9.5.3) | GS 95007-1-2:2013-05 (p. 9.5.3) | GS 95007-1-5:2015-07 (p. 11.4.4) | GS 95007-6-1:2016-03 (p. 9.5.3) | GS 95007-6-2:2017-04 (p. 9.5.3)","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d963","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Rezystywność izolacji / powłoki / Insulation volume resistivity","parameters":[{"name":"Napięcie","range":"(1 - 1000) V D.C."},{"name":"Rezystancja","range":"2 kΩ - 1000 GΩ"},{"name":"Temperatura","range":"do 90°C"},{"name":"Voltage","range":"(1 V - 1000) V DC"},{"name":"Resistance","range":"2 kΩ - 1000 GΩ"},{"name":"Temperature","range":"up to 90 °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Rezystywność izolacji / powłoki / Insulation volume resistivity\nZakres:\nNapięcie (1 - 1000) V D.C.\nRezystancja 2 kΩ - 1000 GΩ\nTemperatura do 90°C\nVoltage (1 V - 1000) V DC\nResistance 2 kΩ - 1000 GΩ\nTemperature up to 90 °C","reference":"ISO 19642-2:2019-01 (p. 5.2.6) | ISO 19642-2:2023 (p. 5.3.6) | ISO 19642-3:2019-01 (p. 5.3.6) | ISO 19642-4:2019-01 (p. 5.3.6) | ISO 19642-5:2019-01 (p. 5.3.6) | ISO 19642-6:2019-01 (p. 5.3.6) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.7) | ISO 6722-2:2013-12-01 (p. 5.7) | LV 112-1:2013-04 (p. 9.5.1) | LV 112-1:2014-04 (p. 9.5.1) | LV 112-2:2007-11 (p. 8.6) | LV 112-2:2013-04 (p. 9.5.1) | LV 212-2:2015-01 (p. 9.5.1) | LV 216-1:2015-07 (p. 9.5.1) | LV 216-2:2017-02 (p. 9.5.1) | VW 60306-1:2018-09-01 (p. 9.5.1) | VW 60306-1:2021-10 (p. 9.6.1) | VW 60306-2:2013-04 (p. 9.5.1) | VW 60306-2:2021-11 (p. 9.6.1) | VW 60306-4:2021-12 (p. 9.6.1) | VW 75205:2019-11 (p. 11.4.2) | VW 75205:2023-05 (p. 11.4.2) | VW 75205:2024-04 (p. 11.5.2) | VW 75209-1:2015-01 (p. 9.5.1) | VW 75209-2:2015-01 (p. 9.5.1) | VW 75209-2:2021-12 (p. 9.6) | VW 75210-1:2023-06 (p. 9.6.1) | VW 75210-1:2024-08 (p. 9.6.1) | VW 75210-2:2023-06 (p. 9.6.1) | MBN LV 112-1:2016-03 (p. 9.5.1) | MBN 50112-1:2023-06 (p. 12.5.1) | MBN LV 112-2:2012-01 (p. 8.6) | MBN 50112-2: 2023-05 (p. 12.6) | MBN 50216-1:2023-07 (p. 12.6.1) | MBN LV 216-2:2017-07 (p. 9.5.1) | MBN 50112-4:2024-06 (p. 12.5.1) | GS 95007-1-1:2013-05 (p. 9.5.1) | GS 95007-1-2:2013-05 (p. 9.5.1) | GS 95007-3-2:2015-09 (p. 9.5.1) | GS 95007-6-1:2016-03 (p. 9.5.1) | GS 95007-6-2:2017-04 (p. 9.5.1)","norm_bases":["ISO 19642-2:2019-01 (p. 5.2.6)","ISO 19642-2:2023 (p. 5.3.6)","ISO 19642-3:2019-01 (p. 5.3.6)","ISO 19642-4:2019-01 (p. 5.3.6)","ISO 19642-5:2019-01 (p. 5.3.6)","ISO 19642-6:2019-01 (p. 5.3.6)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.7)","ISO 6722-2:2013-12-01 (p. 5.7)","LV 112-1:2013-04 (p. 9.5.1)","LV 112-1:2014-04 (p. 9.5.1)","LV 112-2:2007-11 (p. 8.6)","LV 112-2:2013-04 (p. 9.5.1)","LV 212-2:2015-01 (p. 9.5.1)","LV 216-1:2015-07 (p. 9.5.1)","LV 216-2:2017-02 (p. 9.5.1)","VW 60306-1:2018-09-01 (p. 9.5.1)","VW 60306-1:2021-10 (p. 9.6.1)","VW 60306-2:2013-04 (p. 9.5.1)","VW 60306-2:2021-11 (p. 9.6.1)","VW 60306-4:2021-12 (p. 9.6.1)","VW 75205:2019-11 (p. 11.4.2)","VW 75205:2023-05 (p. 11.4.2)","VW 75205:2024-04 (p. 11.5.2)","VW 75209-1:2015-01 (p. 9.5.1)","VW 75209-2:2015-01 (p. 9.5.1)","VW 75209-2:2021-12 (p. 9.6)","VW 75210-1:2023-06 (p. 9.6.1)","VW 75210-1:2024-08 (p. 9.6.1)","VW 75210-2:2023-06 (p. 9.6.1)","MBN LV 112-1:2016-03 (p. 9.5.1)","MBN 50112-1:2023-06 (p. 12.5.1)","MBN LV 112-2:2012-01 (p. 8.6)","MBN 50112-2: 2023-05 (p. 12.6)","MBN 50216-1:2023-07 (p. 12.6.1)","MBN LV 216-2:2017-07 (p. 9.5.1)","MBN 50112-4:2024-06 (p. 12.5.1)","GS 95007-1-1:2013-05 (p. 9.5.1)","GS 95007-1-2:2013-05 (p. 9.5.1)","GS 95007-3-2:2015-09 (p. 9.5.1)","GS 95007-6-1:2016-03 (p. 9.5.1)","GS 95007-6-2:2017-04 (p. 9.5.1)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Rezystywność izolacji / powłoki / Insulation volume resistivity\nZakres:\nNapięcie (1 - 1000) V D.C.\nRezystancja 2 kΩ - 1000 GΩ\nTemperatura do 90°C\nVoltage (1 V - 1000) V DC\nResistance 2 kΩ - 1000 GΩ\nTemperature up to 90 °C ISO 19642-2:2019-01 (p. 5.2.6) | ISO 19642-2:2023 (p. 5.3.6) | ISO 19642-3:2019-01 (p. 5.3.6) | ISO 19642-4:2019-01 (p. 5.3.6) | ISO 19642-5:2019-01 (p. 5.3.6) | ISO 19642-6:2019-01 (p. 5.3.6) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.7) | ISO 6722-2:2013-12-01 (p. 5.7) | LV 112-1:2013-04 (p. 9.5.1) | LV 112-1:2014-04 (p. 9.5.1) | LV 112-2:2007-11 (p. 8.6) | LV 112-2:2013-04 (p. 9.5.1) | LV 212-2:2015-01 (p. 9.5.1) | LV 216-1:2015-07 (p. 9.5.1) | LV 216-2:2017-02 (p. 9.5.1) | VW 60306-1:2018-09-01 (p. 9.5.1) | VW 60306-1:2021-10 (p. 9.6.1) | VW 60306-2:2013-04 (p. 9.5.1) | VW 60306-2:2021-11 (p. 9.6.1) | VW 60306-4:2021-12 (p. 9.6.1) | VW 75205:2019-11 (p. 11.4.2) | VW 75205:2023-05 (p. 11.4.2) | VW 75205:2024-04 (p. 11.5.2) | VW 75209-1:2015-01 (p. 9.5.1) | VW 75209-2:2015-01 (p. 9.5.1) | VW 75209-2:2021-12 (p. 9.6) | VW 75210-1:2023-06 (p. 9.6.1) | VW 75210-1:2024-08 (p. 9.6.1) | VW 75210-2:2023-06 (p. 9.6.1) | MBN LV 112-1:2016-03 (p. 9.5.1) | MBN 50112-1:2023-06 (p. 12.5.1) | MBN LV 112-2:2012-01 (p. 8.6) | MBN 50112-2: 2023-05 (p. 12.6) | MBN 50216-1:2023-07 (p. 12.6.1) | MBN LV 216-2:2017-07 (p. 9.5.1) | MBN 50112-4:2024-06 (p. 12.5.1) | GS 95007-1-1:2013-05 (p. 9.5.1) | GS 95007-1-2:2013-05 (p. 9.5.1) | GS 95007-3-2:2015-09 (p. 9.5.1) | GS 95007-6-1:2016-03 (p. 9.5.1) | GS 95007-6-2:2017-04 (p. 9.5.1) Kable / Cables Rezystywnosc izolacji / powloki / Insulation volume resistivity\nZakres:\nNapiecie (1 - 1000) V D.C.\nRezystancja 2 kΩ - 1000 GΩ\nTemperatura do 90°C\nVoltage (1 V - 1000) V DC\nResistance 2 kΩ - 1000 GΩ\nTemperature up to 90 °C ISO 19642-2:2019-01 (p. 5.2.6) | ISO 19642-2:2023 (p. 5.3.6) | ISO 19642-3:2019-01 (p. 5.3.6) | ISO 19642-4:2019-01 (p. 5.3.6) | ISO 19642-5:2019-01 (p. 5.3.6) | ISO 19642-6:2019-01 (p. 5.3.6) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.7) | ISO 6722-2:2013-12-01 (p. 5.7) | LV 112-1:2013-04 (p. 9.5.1) | LV 112-1:2014-04 (p. 9.5.1) | LV 112-2:2007-11 (p. 8.6) | LV 112-2:2013-04 (p. 9.5.1) | LV 212-2:2015-01 (p. 9.5.1) | LV 216-1:2015-07 (p. 9.5.1) | LV 216-2:2017-02 (p. 9.5.1) | VW 60306-1:2018-09-01 (p. 9.5.1) | VW 60306-1:2021-10 (p. 9.6.1) | VW 60306-2:2013-04 (p. 9.5.1) | VW 60306-2:2021-11 (p. 9.6.1) | VW 60306-4:2021-12 (p. 9.6.1) | VW 75205:2019-11 (p. 11.4.2) | VW 75205:2023-05 (p. 11.4.2) | VW 75205:2024-04 (p. 11.5.2) | VW 75209-1:2015-01 (p. 9.5.1) | VW 75209-2:2015-01 (p. 9.5.1) | VW 75209-2:2021-12 (p. 9.6) | VW 75210-1:2023-06 (p. 9.6.1) | VW 75210-1:2024-08 (p. 9.6.1) | VW 75210-2:2023-06 (p. 9.6.1) | MBN LV 112-1:2016-03 (p. 9.5.1) | MBN 50112-1:2023-06 (p. 12.5.1) | MBN LV 112-2:2012-01 (p. 8.6) | MBN 50112-2: 2023-05 (p. 12.6) | MBN 50216-1:2023-07 (p. 12.6.1) | MBN LV 216-2:2017-07 (p. 9.5.1) | MBN 50112-4:2024-06 (p. 12.5.1) | GS 95007-1-1:2013-05 (p. 9.5.1) | GS 95007-1-2:2013-05 (p. 9.5.1) | GS 95007-3-2:2015-09 (p. 9.5.1) | GS 95007-6-1:2016-03 (p. 9.5.1) | GS 95007-6-2:2017-04 (p. 9.5.1)","categories":["construction"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d964","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Ściągalność izolacji / powłoki / ekranu kabla / Strip force","parameters":[{"name":"Maszyna wytrzymałościowa","range":"do 20 kN"},{"name":"Tensile machine","range":"up to 20 kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Ściągalność izolacji / powłoki / ekranu kabla / Strip force\nZakres:\nMaszyna wytrzymałościowa do 20 kN\nTensile machine up to 20 kN","reference":"ISO 19642-2:2019-01 (p. 5.3.1, 6.3.1) | ISO 19642-2:2023 (p. 5.4.1; 6.4.1; 6.4.7) | ISO 19642-3:2019-01 (p. 5.4.1) | ISO 19642-4:2019-01 (p. 5.4.1) | ISO 19642-5:2019-01 (p. 5.4.1) | ISO 19642-6:2019-01 (p. 5.4.1) | ISO 19642-7:2019-01 (p. 6.4.1) | ISO 19642-8:2019-01 (p. 6.4.1) | ISO 19642-9:2019-01 (p. 6.4.1) | ISO 19642-10:2019-01 (p. 6.4.1) | ISO 6722-1:2011-10-15 ; corr.1:2012-09-15 (p. 5.9) | ISO 6722-2:2013-12-01 (p. 5.9) | ISO 14572:2011-10 (p. 5.8) | LV 112-1:2013-04 (p. 9.3.1) | LV 112-1:2014-04 (p. 9.4) | LV 112-2:2007-11 (p. 8.4.1) | LV 112-2:2013-04 (p. 9.3.1) | LV 212-1:2015-01 (p. 9.3.1) | LV 212-2:2015-01 (p. 9.3.1) | LV 216-1:2015-07 (p. 9.3.1) | LV 216-2:2017-02 (p. 9.3.1) | VW 60306-1:2018-09-01 (p. 9.3.1) | VW 60306-1:2021-10 (p. 9.4.1) | VW 60306-2:2013-04 (p. 9.3.1) | VW 60306-2:2021-11 (p. 9.4.1) | VW 60306-4:2021-12 (p. 9.4.1) | VW 75209-1:2015-01 (p. 9.3.1) | VW 75209-1:2021-12 (p. 9.4.1) | VW 75209-2:2015-01 (p. 9.3.1) | VW 75209-2:2021-12 (p. 9.6.2) | VW 75210-1:2023-06 (p. 9.4.1) | VW 75210-1:2024-08 (p. 9.4.1) | VW 75210-2:2023-06 (p. 9.4.1) | MBN LV 112-1:2016-03 (p. 9.3.1) | MBN 50112-1:2023-06 (p. 12.3.2) | MBN LV 112-2:2012-01 (p. 8.4.1) | MBN 50112-2:2023-05 (p. 12.4.1) | MBN 50216-1:2023-07 (p. 12.4.2) | MBN LV 212-1:2017-08 (p. 9.3.1) | MBN 50212-1:2023-04 (p. 12.4.1) | MBN LV 216-2:2017-07 (p. 9.3.1) | MBN 50112-4:2024-06 (p. 12.3.2) | GS 95007-1-1:2013-05 (p. 9.3.1) | GS 95007-1-2:2013-05 (p. 9.3.1) | GS 95007-3-1:2015-08 (p. 9.3.1) | GS 95007-3-2:2015-09 (p. 9.3.1) | GS 95007-6-1:2016-03 (p. 9.3.1) | GS 95007-6-2:2017-04 (p. 9.3.1)","norm_bases":["ISO 19642-2:2019-01 (p. 5.3.1, 6.3.1)","ISO 19642-2:2023 (p. 5.4.1; 6.4.1; 6.4.7)","ISO 19642-3:2019-01 (p. 5.4.1)","ISO 19642-4:2019-01 (p. 5.4.1)","ISO 19642-5:2019-01 (p. 5.4.1)","ISO 19642-6:2019-01 (p. 5.4.1)","ISO 19642-7:2019-01 (p. 6.4.1)","ISO 19642-8:2019-01 (p. 6.4.1)","ISO 19642-9:2019-01 (p. 6.4.1)","ISO 19642-10:2019-01 (p. 6.4.1)","ISO 6722-1:2011-10-15 ; corr.1:2012-09-15 (p. 5.9)","ISO 6722-2:2013-12-01 (p. 5.9)","ISO 14572:2011-10 (p. 5.8)","LV 112-1:2013-04 (p. 9.3.1)","LV 112-1:2014-04 (p. 9.4)","LV 112-2:2007-11 (p. 8.4.1)","LV 112-2:2013-04 (p. 9.3.1)","LV 212-1:2015-01 (p. 9.3.1)","LV 212-2:2015-01 (p. 9.3.1)","LV 216-1:2015-07 (p. 9.3.1)","LV 216-2:2017-02 (p. 9.3.1)","VW 60306-1:2018-09-01 (p. 9.3.1)","VW 60306-1:2021-10 (p. 9.4.1)","VW 60306-2:2013-04 (p. 9.3.1)","VW 60306-2:2021-11 (p. 9.4.1)","VW 60306-4:2021-12 (p. 9.4.1)","VW 75209-1:2015-01 (p. 9.3.1)","VW 75209-1:2021-12 (p. 9.4.1)","VW 75209-2:2015-01 (p. 9.3.1)","VW 75209-2:2021-12 (p. 9.6.2)","VW 75210-1:2023-06 (p. 9.4.1)","VW 75210-1:2024-08 (p. 9.4.1)","VW 75210-2:2023-06 (p. 9.4.1)","MBN LV 112-1:2016-03 (p. 9.3.1)","MBN 50112-1:2023-06 (p. 12.3.2)","MBN LV 112-2:2012-01 (p. 8.4.1)","MBN 50112-2:2023-05 (p. 12.4.1)","MBN 50216-1:2023-07 (p. 12.4.2)","MBN LV 212-1:2017-08 (p. 9.3.1)","MBN 50212-1:2023-04 (p. 12.4.1)","MBN LV 216-2:2017-07 (p. 9.3.1)","MBN 50112-4:2024-06 (p. 12.3.2)","GS 95007-1-1:2013-05 (p. 9.3.1)","GS 95007-1-2:2013-05 (p. 9.3.1)","GS 95007-3-1:2015-08 (p. 9.3.1)","GS 95007-3-2:2015-09 (p. 9.3.1)","GS 95007-6-1:2016-03 (p. 9.3.1)","GS 95007-6-2:2017-04 (p. 9.3.1)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Ściągalność izolacji / powłoki / ekranu kabla / Strip force\nZakres:\nMaszyna wytrzymałościowa do 20 kN\nTensile machine up to 20 kN ISO 19642-2:2019-01 (p. 5.3.1, 6.3.1) | ISO 19642-2:2023 (p. 5.4.1; 6.4.1; 6.4.7) | ISO 19642-3:2019-01 (p. 5.4.1) | ISO 19642-4:2019-01 (p. 5.4.1) | ISO 19642-5:2019-01 (p. 5.4.1) | ISO 19642-6:2019-01 (p. 5.4.1) | ISO 19642-7:2019-01 (p. 6.4.1) | ISO 19642-8:2019-01 (p. 6.4.1) | ISO 19642-9:2019-01 (p. 6.4.1) | ISO 19642-10:2019-01 (p. 6.4.1) | ISO 6722-1:2011-10-15 ; corr.1:2012-09-15 (p. 5.9) | ISO 6722-2:2013-12-01 (p. 5.9) | ISO 14572:2011-10 (p. 5.8) | LV 112-1:2013-04 (p. 9.3.1) | LV 112-1:2014-04 (p. 9.4) | LV 112-2:2007-11 (p. 8.4.1) | LV 112-2:2013-04 (p. 9.3.1) | LV 212-1:2015-01 (p. 9.3.1) | LV 212-2:2015-01 (p. 9.3.1) | LV 216-1:2015-07 (p. 9.3.1) | LV 216-2:2017-02 (p. 9.3.1) | VW 60306-1:2018-09-01 (p. 9.3.1) | VW 60306-1:2021-10 (p. 9.4.1) | VW 60306-2:2013-04 (p. 9.3.1) | VW 60306-2:2021-11 (p. 9.4.1) | VW 60306-4:2021-12 (p. 9.4.1) | VW 75209-1:2015-01 (p. 9.3.1) | VW 75209-1:2021-12 (p. 9.4.1) | VW 75209-2:2015-01 (p. 9.3.1) | VW 75209-2:2021-12 (p. 9.6.2) | VW 75210-1:2023-06 (p. 9.4.1) | VW 75210-1:2024-08 (p. 9.4.1) | VW 75210-2:2023-06 (p. 9.4.1) | MBN LV 112-1:2016-03 (p. 9.3.1) | MBN 50112-1:2023-06 (p. 12.3.2) | MBN LV 112-2:2012-01 (p. 8.4.1) | MBN 50112-2:2023-05 (p. 12.4.1) | MBN 50216-1:2023-07 (p. 12.4.2) | MBN LV 212-1:2017-08 (p. 9.3.1) | MBN 50212-1:2023-04 (p. 12.4.1) | MBN LV 216-2:2017-07 (p. 9.3.1) | MBN 50112-4:2024-06 (p. 12.3.2) | GS 95007-1-1:2013-05 (p. 9.3.1) | GS 95007-1-2:2013-05 (p. 9.3.1) | GS 95007-3-1:2015-08 (p. 9.3.1) | GS 95007-3-2:2015-09 (p. 9.3.1) | GS 95007-6-1:2016-03 (p. 9.3.1) | GS 95007-6-2:2017-04 (p. 9.3.1) Kable / Cables Sciagalnosc izolacji / powloki / ekranu kabla / Strip force\nZakres:\nMaszyna wytrzymalosciowa do 20 kN\nTensile machine up to 20 kN ISO 19642-2:2019-01 (p. 5.3.1, 6.3.1) | ISO 19642-2:2023 (p. 5.4.1; 6.4.1; 6.4.7) | ISO 19642-3:2019-01 (p. 5.4.1) | ISO 19642-4:2019-01 (p. 5.4.1) | ISO 19642-5:2019-01 (p. 5.4.1) | ISO 19642-6:2019-01 (p. 5.4.1) | ISO 19642-7:2019-01 (p. 6.4.1) | ISO 19642-8:2019-01 (p. 6.4.1) | ISO 19642-9:2019-01 (p. 6.4.1) | ISO 19642-10:2019-01 (p. 6.4.1) | ISO 6722-1:2011-10-15 ; corr.1:2012-09-15 (p. 5.9) | ISO 6722-2:2013-12-01 (p. 5.9) | ISO 14572:2011-10 (p. 5.8) | LV 112-1:2013-04 (p. 9.3.1) | LV 112-1:2014-04 (p. 9.4) | LV 112-2:2007-11 (p. 8.4.1) | LV 112-2:2013-04 (p. 9.3.1) | LV 212-1:2015-01 (p. 9.3.1) | LV 212-2:2015-01 (p. 9.3.1) | LV 216-1:2015-07 (p. 9.3.1) | LV 216-2:2017-02 (p. 9.3.1) | VW 60306-1:2018-09-01 (p. 9.3.1) | VW 60306-1:2021-10 (p. 9.4.1) | VW 60306-2:2013-04 (p. 9.3.1) | VW 60306-2:2021-11 (p. 9.4.1) | VW 60306-4:2021-12 (p. 9.4.1) | VW 75209-1:2015-01 (p. 9.3.1) | VW 75209-1:2021-12 (p. 9.4.1) | VW 75209-2:2015-01 (p. 9.3.1) | VW 75209-2:2021-12 (p. 9.6.2) | VW 75210-1:2023-06 (p. 9.4.1) | VW 75210-1:2024-08 (p. 9.4.1) | VW 75210-2:2023-06 (p. 9.4.1) | MBN LV 112-1:2016-03 (p. 9.3.1) | MBN 50112-1:2023-06 (p. 12.3.2) | MBN LV 112-2:2012-01 (p. 8.4.1) | MBN 50112-2:2023-05 (p. 12.4.1) | MBN 50216-1:2023-07 (p. 12.4.2) | MBN LV 212-1:2017-08 (p. 9.3.1) | MBN 50212-1:2023-04 (p. 12.4.1) | MBN LV 216-2:2017-07 (p. 9.3.1) | MBN 50112-4:2024-06 (p. 12.3.2) | GS 95007-1-1:2013-05 (p. 9.3.1) | GS 95007-1-2:2013-05 (p. 9.3.1) | GS 95007-3-1:2015-08 (p. 9.3.1) | GS 95007-3-2:2015-09 (p. 9.3.1) | GS 95007-6-1:2016-03 (p. 9.3.1) | GS 95007-6-2:2017-04 (p. 9.3.1)","categories":["construction"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d965","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Odporność izolacji / powłoki kabla na przetarcie / Scrape abrasion test","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność izolacji / powłoki kabla na przetarcie / Scrape abrasion test","reference":"ISO 19642-2 2019-01 (p. 5.3.2.5) | ISO 19642-2:2023 (p. 5.4.2.5; 6.4.8.6) | ISO 19642-3:2019-01 (p. 5.4.2.3) | ISO 19642-4:2019-01 (p. 5.4.2.3) | ISO 19642-5:2019-01 (p. 5.4.2.3) | ISO 19642-6:2019-01 (p. 5.4.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.12.4.2) | ISO 6722-2:2013-12-01 (p. 5.12) | LV 112-1:2013-04 (p. 9.3.2) | LV 112-1:2014-04 (p. 9.3.2) | LV 112-2:2007-11 (p. 8.4.2) | LV 112-2:2013-04 (p. 9.3.2) | LV 212-1:2015-01 (p. 9.3.2) | LV 216-1:2015-07 (p. 9.3.2) | LV 212-2:2015-01 (p. 9.3.2) | LV 216-2:2017-02 (p. 9.3.2) | VW 60306-1:2018-09-01 (p. 9.3.2) | VW 60306-1:2021-10 (p. 9.4.2) | VW 60306-2:2013-04 (p. 9.3.2) | VW 60306-2:2021-11 (p. 9.4.2) | VW 60306-4:2021-12 (p. 9.4.2) | VW 75209-1:2015-01 (p. 9.3.2) | VW 75209-1:2021-12 (p. 9.4.2) | VW 75209-2:2015-01 (p. 9.3.2) | VW 75209-2:2021-12 (p. 9.4.1) | VW 75210-1:2023-06 (p. 9.4.2) | VW 75210-1:2024-08 (p. 9.4.2) | VW 75210-2:2023-06 (p. 9.4.2) | MBN LV 112-1:2016-03 (p. 9.3.2) | MBN 50112-1:2023-06 (p. 12.3.3) | MBN LV 112-2:2012-01 (p. 8.4.2) | MBN 50112-2:2023-05 (p. 12.4.2) | MBN 50216-1:2023-07 (p. 12.4.3) | MBN LV 212-1:2017-08 (p. 9.3.2) | MBN 50212-1:2023-04 (p. 12.4.2) | MBN LV 216-2:2017-07 (p. 9.3.2) | MBN 50112-4:2024-06 (p. 12.3.3) | GS 95007-1-1:2013-05 (p. 9.3.2) | GS 95007-1-2:2013-05 (p. 9.3.2) | GS 95007-3-1:2015-08 (p. 9.3.2) | GS 95007-3-2:2015-09 (p. 9.3.2) | GS 95007-6-1:2016-03 (p. 9.3.2) | GS 95007-6-2:2017-04 (p. 9.3.2)","norm_bases":["ISO 19642-2 2019-01 (p. 5.3.2.5)","ISO 19642-2:2023 (p. 5.4.2.5; 6.4.8.6)","ISO 19642-3:2019-01 (p. 5.4.2.3)","ISO 19642-4:2019-01 (p. 5.4.2.3)","ISO 19642-5:2019-01 (p. 5.4.2.3)","ISO 19642-6:2019-01 (p. 5.4.2.3)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.12.4.2)","ISO 6722-2:2013-12-01 (p. 5.12)","LV 112-1:2013-04 (p. 9.3.2)","LV 112-1:2014-04 (p. 9.3.2)","LV 112-2:2007-11 (p. 8.4.2)","LV 112-2:2013-04 (p. 9.3.2)","LV 212-1:2015-01 (p. 9.3.2)","LV 216-1:2015-07 (p. 9.3.2)","LV 212-2:2015-01 (p. 9.3.2)","LV 216-2:2017-02 (p. 9.3.2)","VW 60306-1:2018-09-01 (p. 9.3.2)","VW 60306-1:2021-10 (p. 9.4.2)","VW 60306-2:2013-04 (p. 9.3.2)","VW 60306-2:2021-11 (p. 9.4.2)","VW 60306-4:2021-12 (p. 9.4.2)","VW 75209-1:2015-01 (p. 9.3.2)","VW 75209-1:2021-12 (p. 9.4.2)","VW 75209-2:2015-01 (p. 9.3.2)","VW 75209-2:2021-12 (p. 9.4.1)","VW 75210-1:2023-06 (p. 9.4.2)","VW 75210-1:2024-08 (p. 9.4.2)","VW 75210-2:2023-06 (p. 9.4.2)","MBN LV 112-1:2016-03 (p. 9.3.2)","MBN 50112-1:2023-06 (p. 12.3.3)","MBN LV 112-2:2012-01 (p. 8.4.2)","MBN 50112-2:2023-05 (p. 12.4.2)","MBN 50216-1:2023-07 (p. 12.4.3)","MBN LV 212-1:2017-08 (p. 9.3.2)","MBN 50212-1:2023-04 (p. 12.4.2)","MBN LV 216-2:2017-07 (p. 9.3.2)","MBN 50112-4:2024-06 (p. 12.3.3)","GS 95007-1-1:2013-05 (p. 9.3.2)","GS 95007-1-2:2013-05 (p. 9.3.2)","GS 95007-3-1:2015-08 (p. 9.3.2)","GS 95007-3-2:2015-09 (p. 9.3.2)","GS 95007-6-1:2016-03 (p. 9.3.2)","GS 95007-6-2:2017-04 (p. 9.3.2)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Odporność izolacji / powłoki kabla na przetarcie / Scrape abrasion test ISO 19642-2 2019-01 (p. 5.3.2.5) | ISO 19642-2:2023 (p. 5.4.2.5; 6.4.8.6) | ISO 19642-3:2019-01 (p. 5.4.2.3) | ISO 19642-4:2019-01 (p. 5.4.2.3) | ISO 19642-5:2019-01 (p. 5.4.2.3) | ISO 19642-6:2019-01 (p. 5.4.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.12.4.2) | ISO 6722-2:2013-12-01 (p. 5.12) | LV 112-1:2013-04 (p. 9.3.2) | LV 112-1:2014-04 (p. 9.3.2) | LV 112-2:2007-11 (p. 8.4.2) | LV 112-2:2013-04 (p. 9.3.2) | LV 212-1:2015-01 (p. 9.3.2) | LV 216-1:2015-07 (p. 9.3.2) | LV 212-2:2015-01 (p. 9.3.2) | LV 216-2:2017-02 (p. 9.3.2) | VW 60306-1:2018-09-01 (p. 9.3.2) | VW 60306-1:2021-10 (p. 9.4.2) | VW 60306-2:2013-04 (p. 9.3.2) | VW 60306-2:2021-11 (p. 9.4.2) | VW 60306-4:2021-12 (p. 9.4.2) | VW 75209-1:2015-01 (p. 9.3.2) | VW 75209-1:2021-12 (p. 9.4.2) | VW 75209-2:2015-01 (p. 9.3.2) | VW 75209-2:2021-12 (p. 9.4.1) | VW 75210-1:2023-06 (p. 9.4.2) | VW 75210-1:2024-08 (p. 9.4.2) | VW 75210-2:2023-06 (p. 9.4.2) | MBN LV 112-1:2016-03 (p. 9.3.2) | MBN 50112-1:2023-06 (p. 12.3.3) | MBN LV 112-2:2012-01 (p. 8.4.2) | MBN 50112-2:2023-05 (p. 12.4.2) | MBN 50216-1:2023-07 (p. 12.4.3) | MBN LV 212-1:2017-08 (p. 9.3.2) | MBN 50212-1:2023-04 (p. 12.4.2) | MBN LV 216-2:2017-07 (p. 9.3.2) | MBN 50112-4:2024-06 (p. 12.3.3) | GS 95007-1-1:2013-05 (p. 9.3.2) | GS 95007-1-2:2013-05 (p. 9.3.2) | GS 95007-3-1:2015-08 (p. 9.3.2) | GS 95007-3-2:2015-09 (p. 9.3.2) | GS 95007-6-1:2016-03 (p. 9.3.2) | GS 95007-6-2:2017-04 (p. 9.3.2) Kable / Cables Odpornosc izolacji / powloki kabla na przetarcie / Scrape abrasion test ISO 19642-2 2019-01 (p. 5.3.2.5) | ISO 19642-2:2023 (p. 5.4.2.5; 6.4.8.6) | ISO 19642-3:2019-01 (p. 5.4.2.3) | ISO 19642-4:2019-01 (p. 5.4.2.3) | ISO 19642-5:2019-01 (p. 5.4.2.3) | ISO 19642-6:2019-01 (p. 5.4.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.12.4.2) | ISO 6722-2:2013-12-01 (p. 5.12) | LV 112-1:2013-04 (p. 9.3.2) | LV 112-1:2014-04 (p. 9.3.2) | LV 112-2:2007-11 (p. 8.4.2) | LV 112-2:2013-04 (p. 9.3.2) | LV 212-1:2015-01 (p. 9.3.2) | LV 216-1:2015-07 (p. 9.3.2) | LV 212-2:2015-01 (p. 9.3.2) | LV 216-2:2017-02 (p. 9.3.2) | VW 60306-1:2018-09-01 (p. 9.3.2) | VW 60306-1:2021-10 (p. 9.4.2) | VW 60306-2:2013-04 (p. 9.3.2) | VW 60306-2:2021-11 (p. 9.4.2) | VW 60306-4:2021-12 (p. 9.4.2) | VW 75209-1:2015-01 (p. 9.3.2) | VW 75209-1:2021-12 (p. 9.4.2) | VW 75209-2:2015-01 (p. 9.3.2) | VW 75209-2:2021-12 (p. 9.4.1) | VW 75210-1:2023-06 (p. 9.4.2) | VW 75210-1:2024-08 (p. 9.4.2) | VW 75210-2:2023-06 (p. 9.4.2) | MBN LV 112-1:2016-03 (p. 9.3.2) | MBN 50112-1:2023-06 (p. 12.3.3) | MBN LV 112-2:2012-01 (p. 8.4.2) | MBN 50112-2:2023-05 (p. 12.4.2) | MBN 50216-1:2023-07 (p. 12.4.3) | MBN LV 212-1:2017-08 (p. 9.3.2) | MBN 50212-1:2023-04 (p. 12.4.2) | MBN LV 216-2:2017-07 (p. 9.3.2) | MBN 50112-4:2024-06 (p. 12.3.3) | GS 95007-1-1:2013-05 (p. 9.3.2) | GS 95007-1-2:2013-05 (p. 9.3.2) | GS 95007-3-1:2015-08 (p. 9.3.2) | GS 95007-3-2:2015-09 (p. 9.3.2) | GS 95007-6-1:2016-03 (p. 9.3.2) | GS 95007-6-2:2017-04 (p. 9.3.2)","categories":["construction"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d966","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Siła zrywająca gotowy kabel / Breaking strength of finished cable","parameters":[{"name":"Maszyna wytrzymałościowa","range":"do 20 kN"},{"name":"Tensile machine","range":"up to 20 kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Siła zrywająca gotowy kabel / Breaking strength of finished cable\nZakres:\nMaszyna wytrzymałościowa do 20 kN\nTensile machine up to 20 kN","reference":"ISO 19642-2:2019-01 (p. 5.3.3) | ISO 19642-2:2023 (p. 5.4.3) | ISO 19642-3:2019-01 (p. 5.4.3) | ISO 19642-4:2019-01 (p. 5.4.3) | ISO 19642-5:2019-01 (p. 5.4.3) | ISO 19642-6:2019-01 (p. 5.4.3)","norm_bases":["ISO 19642-2:2019-01 (p. 5.3.3)","ISO 19642-2:2023 (p. 5.4.3)","ISO 19642-3:2019-01 (p. 5.4.3)","ISO 19642-4:2019-01 (p. 5.4.3)","ISO 19642-5:2019-01 (p. 5.4.3)","ISO 19642-6:2019-01 (p. 5.4.3)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Siła zrywająca gotowy kabel / Breaking strength of finished cable\nZakres:\nMaszyna wytrzymałościowa do 20 kN\nTensile machine up to 20 kN ISO 19642-2:2019-01 (p. 5.3.3) | ISO 19642-2:2023 (p. 5.4.3) | ISO 19642-3:2019-01 (p. 5.4.3) | ISO 19642-4:2019-01 (p. 5.4.3) | ISO 19642-5:2019-01 (p. 5.4.3) | ISO 19642-6:2019-01 (p. 5.4.3) Kable / Cables Sila zrywajaca gotowy kabel / Breaking strength of finished cable\nZakres:\nMaszyna wytrzymalosciowa do 20 kN\nTensile machine up to 20 kN ISO 19642-2:2019-01 (p. 5.3.3) | ISO 19642-2:2023 (p. 5.4.3) | ISO 19642-3:2019-01 (p. 5.4.3) | ISO 19642-4:2019-01 (p. 5.4.3) | ISO 19642-5:2019-01 (p. 5.4.3) | ISO 19642-6:2019-01 (p. 5.4.3)","categories":["other"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d967","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Test elastyczności kabla / Flexibility test","parameters":[{"name":"Zakres","range":"kable o średnicy zewnętrznej ≤ 28 mm"},{"name":"Range","range":"cable with outer diameter ≤ 28 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Test elastyczności kabla / Flexibility test\nZakres:\nZakres kable o średnicy zewnętrznej ≤ 28 mm\nRange cable with outer diameter ≤ 28 mm","reference":"ISO 19642-2:2019-01 (p. 5.3.5; 6.3.3) | ISO 19642-2:2023 (p. 5.4.5; 6.4.3) | ISO 19642-3:2019-01 (p. 5.4.5) | ISO 19642-4:2019-01 (p. 5.4.5) | ISO 19642-5:2019-01 (p. 5.4.5) | ISO 19642-6:2019-01 (p. 5.4.5) | ISO 19642-7:2019-01 (p. 6.4.3) | ISO 19642-8:2019-01 (p. 6.4.3) | ISO 19642-9:2019-01 (p. 6.4.3) | ISO 19642-10:2019-01 (p. 6.4.3)","norm_bases":["ISO 19642-2:2019-01 (p. 5.3.5; 6.3.3)","ISO 19642-2:2023 (p. 5.4.5; 6.4.3)","ISO 19642-3:2019-01 (p. 5.4.5)","ISO 19642-4:2019-01 (p. 5.4.5)","ISO 19642-5:2019-01 (p. 5.4.5)","ISO 19642-6:2019-01 (p. 5.4.5)","ISO 19642-7:2019-01 (p. 6.4.3)","ISO 19642-8:2019-01 (p. 6.4.3)","ISO 19642-9:2019-01 (p. 6.4.3)","ISO 19642-10:2019-01 (p. 6.4.3)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Test elastyczności kabla / Flexibility test\nZakres:\nZakres kable o średnicy zewnętrznej ≤ 28 mm\nRange cable with outer diameter ≤ 28 mm ISO 19642-2:2019-01 (p. 5.3.5; 6.3.3) | ISO 19642-2:2023 (p. 5.4.5; 6.4.3) | ISO 19642-3:2019-01 (p. 5.4.5) | ISO 19642-4:2019-01 (p. 5.4.5) | ISO 19642-5:2019-01 (p. 5.4.5) | ISO 19642-6:2019-01 (p. 5.4.5) | ISO 19642-7:2019-01 (p. 6.4.3) | ISO 19642-8:2019-01 (p. 6.4.3) | ISO 19642-9:2019-01 (p. 6.4.3) | ISO 19642-10:2019-01 (p. 6.4.3) Kable / Cables Test elastycznosci kabla / Flexibility test\nZakres:\nZakres kable o srednicy zewnetrznej ≤ 28 mm\nRange cable with outer diameter ≤ 28 mm ISO 19642-2:2019-01 (p. 5.3.5; 6.3.3) | ISO 19642-2:2023 (p. 5.4.5; 6.4.3) | ISO 19642-3:2019-01 (p. 5.4.5) | ISO 19642-4:2019-01 (p. 5.4.5) | ISO 19642-5:2019-01 (p. 5.4.5) | ISO 19642-6:2019-01 (p. 5.4.5) | ISO 19642-7:2019-01 (p. 6.4.3) | ISO 19642-8:2019-01 (p. 6.4.3) | ISO 19642-9:2019-01 (p. 6.4.3) | ISO 19642-10:2019-01 (p. 6.4.3)","categories":["other"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d968","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Test nawijania kabla / Winding test","parameters":[{"name":"Komora klimatyczna","range":"- 40 °C do 125 °C"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Zakres","range":"0,5 kV do 6 kV D.C."},{"name":"Climatic chamber","range":"-40 °C to 125 °C"},{"name":"Range","range":"0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Range","range":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"computed":[],"activity":"Test nawijania kabla / Winding test\nZakres:\nKomora klimatyczna - 40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nClimatic chamber -40 °C to 125 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C.","reference":"ISO 19642-2:2019-01 (p. 5.4.1; 6.4.1) | ISO 19642-2:2023 (p. 5.5.1; 6.5.1) | ISO 19642-3:2019-01 (p. 5.5.1) | ISO 19642-4:2019-01 (p. 5.5.1) | ISO 19642-5:2019-01 (p. 5.5.1) | ISO 19642-6:2019-01 (p. 5.5.1) | ISO 19642-7:2019-01 (p. 6.5.1) | ISO 19642-8:2019-01 (p. 6.5.1) | ISO 19642-9:2019-01 (p. 6.5.1) | ISO 19642-10:2019-01 (p. 6.5.1)","norm_bases":["ISO 19642-2:2019-01 (p. 5.4.1; 6.4.1)","ISO 19642-2:2023 (p. 5.5.1; 6.5.1)","ISO 19642-3:2019-01 (p. 5.5.1)","ISO 19642-4:2019-01 (p. 5.5.1)","ISO 19642-5:2019-01 (p. 5.5.1)","ISO 19642-6:2019-01 (p. 5.5.1)","ISO 19642-7:2019-01 (p. 6.5.1)","ISO 19642-8:2019-01 (p. 6.5.1)","ISO 19642-9:2019-01 (p. 6.5.1)","ISO 19642-10:2019-01 (p. 6.5.1)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Test nawijania kabla / Winding test\nZakres:\nKomora klimatyczna - 40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nClimatic chamber -40 °C to 125 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. ISO 19642-2:2019-01 (p. 5.4.1; 6.4.1) | ISO 19642-2:2023 (p. 5.5.1; 6.5.1) | ISO 19642-3:2019-01 (p. 5.5.1) | ISO 19642-4:2019-01 (p. 5.5.1) | ISO 19642-5:2019-01 (p. 5.5.1) | ISO 19642-6:2019-01 (p. 5.5.1) | ISO 19642-7:2019-01 (p. 6.5.1) | ISO 19642-8:2019-01 (p. 6.5.1) | ISO 19642-9:2019-01 (p. 6.5.1) | ISO 19642-10:2019-01 (p. 6.5.1) Kable / Cables Test nawijania kabla / Winding test\nZakres:\nKomora klimatyczna - 40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nClimatic chamber -40 °C to 125 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. ISO 19642-2:2019-01 (p. 5.4.1; 6.4.1) | ISO 19642-2:2023 (p. 5.5.1; 6.5.1) | ISO 19642-3:2019-01 (p. 5.5.1) | ISO 19642-4:2019-01 (p. 5.5.1) | ISO 19642-5:2019-01 (p. 5.5.1) | ISO 19642-6:2019-01 (p. 5.5.1) | ISO 19642-7:2019-01 (p. 6.5.1) | ISO 19642-8:2019-01 (p. 6.5.1) | ISO 19642-9:2019-01 (p. 6.5.1) | ISO 19642-10:2019-01 (p. 6.5.1)","categories":["other"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d969","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Badania starzeniowe: - długotrwałe starzenie kabla (3000 h) - krótkotrwałe starzenie kabla (240 h) - przeciążenie cieplne kabli - starzenie krótkotrwałe PVC / Aging tests: - long-term heat aging (3000 h) - short-term heat aging (240 h) - thermal overload - short-term heat aging for PVC","parameters":[{"name":"Piec","range":"do 200 °C (± 2 °C)"},{"name":"Komora klimatyczna","range":"- 40 °C do 125 °C"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Zakres","range":"0,5 kV do 6 kV D.C."},{"name":"Aging oven","range":"up to 200 °C (± 2 °C)"},{"name":"Climatic chamber","range":"-40 °C to 125 °C"},{"name":"Range","range":"0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Range","range":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"computed":[],"activity":"Badania starzeniowe: - długotrwałe starzenie kabla (3000 h) - krótkotrwałe starzenie kabla (240 h) - przeciążenie cieplne kabli - starzenie krótkotrwałe PVC / Aging tests: - long-term heat aging (3000 h) - short-term heat aging (240 h) - thermal overload - short-term heat aging for PVC\nZakres:\nPiec do 200 °C (± 2 °C)\nKomora klimatyczna - 40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging oven up to 200 °C (± 2 °C)\nClimatic chamber -40 °C to 125 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C.","reference":"ISO 19642-2:2019-01 (p. 5.4.2; 5.4.3; 5.4.4; 6.4.2; 6.4.3; 6.4.4) | ISO 19642-2:2023 (p. 5.5.2; 5.5.3; 5.5.4; 6.5.2; 6.5.3; 6.5.4) | ISO 19642-3:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-4:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-5:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-6:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-7:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-8:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-9: 2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-10:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.13; 5.14; 5.15) | ISO 6722-2:2013-12-01 (p. 5.13; 5.14; 5.15) | ISO 14572:2011-10 (p. 5.13; 5.14; 5.15) | LV 112-1:2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1; 9.6.6) | LV 112-1:2014-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1; 9.7.6) | LV 112-2:2007-11 (p. 8.7.6; 8.7.5; 8.7.7) | LV 112-2: 2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | LV 122:2015-05 (p. 11.5.1.1; 11.5.1.2) | LV 122:2016-02 (p. 11.5.5; 11.5.5.2) | LV 212-1:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | LV 212-2:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | LV 216-1:2015-07 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | LV 216-2:2017-02 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1)","norm_bases":["ISO 19642-2:2019-01 (p. 5.4.2; 5.4.3; 5.4.4; 6.4.2; 6.4.3; 6.4.4)","ISO 19642-2:2023 (p. 5.5.2; 5.5.3; 5.5.4; 6.5.2; 6.5.3; 6.5.4)","ISO 19642-3:2019-01 (p. 5.5.2; 5.5.3; 5.5.4)","ISO 19642-4:2019-01 (p. 5.5.2; 5.5.3; 5.5.4)","ISO 19642-5:2019-01 (p. 5.5.2; 5.5.3; 5.5.4)","ISO 19642-6:2019-01 (p. 5.5.2; 5.5.3; 5.5.4)","ISO 19642-7:2019-01 (p. 6.5.2; 6.5.3; 6.5.4)","ISO 19642-8:2019-01 (p. 6.5.2; 6.5.3; 6.5.4)","ISO 19642-9: 2019-01 (p. 6.5.2; 6.5.3; 6.5.4)","ISO 19642-10:2019-01 (p. 6.5.2; 6.5.3; 6.5.4)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.13; 5.14; 5.15)","ISO 6722-2:2013-12-01 (p. 5.13; 5.14; 5.15)","ISO 14572:2011-10 (p. 5.13; 5.14; 5.15)","LV 112-1:2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1; 9.6.6)","LV 112-1:2014-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1; 9.7.6)","LV 112-2:2007-11 (p. 8.7.6; 8.7.5; 8.7.7)","LV 112-2: 2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1)","LV 122:2015-05 (p. 11.5.1.1; 11.5.1.2)","LV 122:2016-02 (p. 11.5.5; 11.5.5.2)","LV 212-1:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1)","LV 212-2:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1)","LV 216-1:2015-07 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1)","LV 216-2:2017-02 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Badania starzeniowe: - długotrwałe starzenie kabla (3000 h) - krótkotrwałe starzenie kabla (240 h) - przeciążenie cieplne kabli - starzenie krótkotrwałe PVC / Aging tests: - long-term heat aging (3000 h) - short-term heat aging (240 h) - thermal overload - short-term heat aging for PVC\nZakres:\nPiec do 200 °C (± 2 °C)\nKomora klimatyczna - 40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging oven up to 200 °C (± 2 °C)\nClimatic chamber -40 °C to 125 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. ISO 19642-2:2019-01 (p. 5.4.2; 5.4.3; 5.4.4; 6.4.2; 6.4.3; 6.4.4) | ISO 19642-2:2023 (p. 5.5.2; 5.5.3; 5.5.4; 6.5.2; 6.5.3; 6.5.4) | ISO 19642-3:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-4:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-5:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-6:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-7:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-8:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-9: 2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-10:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.13; 5.14; 5.15) | ISO 6722-2:2013-12-01 (p. 5.13; 5.14; 5.15) | ISO 14572:2011-10 (p. 5.13; 5.14; 5.15) | LV 112-1:2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1; 9.6.6) | LV 112-1:2014-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1; 9.7.6) | LV 112-2:2007-11 (p. 8.7.6; 8.7.5; 8.7.7) | LV 112-2: 2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | LV 122:2015-05 (p. 11.5.1.1; 11.5.1.2) | LV 122:2016-02 (p. 11.5.5; 11.5.5.2) | LV 212-1:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | LV 212-2:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | LV 216-1:2015-07 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | LV 216-2:2017-02 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) Kable / Cables Badania starzeniowe: - dlugotrwale starzenie kabla (3000 h) - krotkotrwale starzenie kabla (240 h) - przeciazenie cieplne kabli - starzenie krotkotrwale PVC / Aging tests: - long-term heat aging (3000 h) - short-term heat aging (240 h) - thermal overload - short-term heat aging for PVC\nZakres:\nPiec do 200 °C (± 2 °C)\nKomora klimatyczna - 40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging oven up to 200 °C (± 2 °C)\nClimatic chamber -40 °C to 125 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. ISO 19642-2:2019-01 (p. 5.4.2; 5.4.3; 5.4.4; 6.4.2; 6.4.3; 6.4.4) | ISO 19642-2:2023 (p. 5.5.2; 5.5.3; 5.5.4; 6.5.2; 6.5.3; 6.5.4) | ISO 19642-3:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-4:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-5:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-6:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-7:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-8:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-9: 2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-10:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.13; 5.14; 5.15) | ISO 6722-2:2013-12-01 (p. 5.13; 5.14; 5.15) | ISO 14572:2011-10 (p. 5.13; 5.14; 5.15) | LV 112-1:2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1; 9.6.6) | LV 112-1:2014-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1; 9.7.6) | LV 112-2:2007-11 (p. 8.7.6; 8.7.5; 8.7.7) | LV 112-2: 2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | LV 122:2015-05 (p. 11.5.1.1; 11.5.1.2) | LV 122:2016-02 (p. 11.5.5; 11.5.5.2) | LV 212-1:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | LV 212-2:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | LV 216-1:2015-07 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | LV 216-2:2017-02 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1)","categories":["other"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d96a","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Badania starzeniowe: - długotrwałe starzenie kabla (3000 h) - krótkotrwałe starzenie kabla (240 h) - przeciążenie cieplne kabli - starzenie krótkotrwałe PVC / Aging tests: - long-term heat aging (3000 h) - short-term heat aging (240 h) - thermal overload - short-term heat aging for PVC","parameters":[{"name":"Piec","range":"do 200 °C (± 2 °C)"},{"name":"Komora klimatyczna","range":"- 40 °C do 125 °C"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Zakres","range":"0,5 kV do 6 kV D.C."},{"name":"Aging oven","range":"up to 200 °C (± 2 °C)"},{"name":"Climatic chamber","range":"-40 °C to 125 °C"},{"name":"Range","range":"0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Range","range":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"computed":[],"activity":"Badania starzeniowe: - długotrwałe starzenie kabla (3000 h) - krótkotrwałe starzenie kabla (240 h) - przeciążenie cieplne kabli - starzenie krótkotrwałe PVC / Aging tests: - long-term heat aging (3000 h) - short-term heat aging (240 h) - thermal overload - short-term heat aging for PVC\nZakres:\nPiec do 200 °C (± 2 °C)\nKomora klimatyczna - 40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging oven up to 200 °C (± 2 °C)\nClimatic chamber -40 °C to 125 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C.","reference":"VW 60306-1:2018-09-01 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | VW 60306-1:2021-10 (p. 9.7.7; 9.7.6.1; 9.7.7.2; 9.7.8; 9.7.8.2) | VW 60306-2:2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | VW 60306-2:2021-11 (p. 9.7.7; 9.7.7.2; 9.7.6.1; 9.7.8; 9.7.8.2) | VW 60306-4:2021-12 (p. 9.7.6.1; 9.7.7; 9.7.7.2; 9.7.8; 9.7.8.2) | VW 75205:2019-11 (p. 11.5.1.1; 11.5.1.2) | VW 75205:2023-05 (p. 11.5.1.1; 11.5.1.2) | VW 75205:2024-04 (p. 11.6.1.1; 11.6.1.2) | VW 75209-1:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | VW 75209-1:2021-12 (p. 9.7.5; 9.7.5.2; 9.7.4; 9.7.6; 9.7.6.2) | VW 75209-2:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | VW 75209-2:2021-12 (p.9.7.4; 9.7.5.2; 9.7.3; 9.7.6; 9.7.6.2; 9.7.5) | VW 75210-1:2023-06 (p. 9.7.6; 9.7.6.1; 9.7.6.2; 9.7.7; 9.7.8; 9.7.8.1) | VW 75210-1:2024-08 (p. 9.7.6, 9.7.6.1; 9.7.6.2; 9.7.7; 9.7.7.1; 9.7.8; 9.7.8.1) | VW 75210-2:2023-06 (p. 9.7.5; 9.7.6; 9.7.7; 9.7.7.1) | MBN LV 112-1:2016-03 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | MBN LV 122:2017-06 (p. 11.5.5; 11.5.5.2) | MBN 50122:2023-07 (p. 13.5.5; 13.5.5.2) | MBN LV 212-1:2017-08 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | MBN 50212-1:2023-04 (p. 12.7.5; 12.7.6; 12.7.6.1; 12.7.6.2; 12.7.7; 12.7.7.1; 12.7.7.2) | MBN LV 216-2:2017-07 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | GS 95007-1-1:2013-05 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | GS 95007-1-2:2013-05 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | GS 95007-1-5:2015-07 (p. 11.5.1.1; 11.5.1.2) | GS 95007-3-1:2015-08 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | GS 95007-3-2:2015-09 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | GS 95007-6-1:2016-03 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | GS 95007-6-2:2017-04 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | MBN 50112-1:2023-06 (12.6.6.1; 12.6.7.1; 12.6.7.2; 12.6.8.1; 12.6.8.2)","norm_bases":["VW 60306-1:2018-09-01 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1)","VW 60306-1:2021-10 (p. 9.7.7; 9.7.6.1; 9.7.7.2; 9.7.8; 9.7.8.2)","VW 60306-2:2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1)","VW 60306-2:2021-11 (p. 9.7.7; 9.7.7.2; 9.7.6.1; 9.7.8; 9.7.8.2)","VW 60306-4:2021-12 (p. 9.7.6.1; 9.7.7; 9.7.7.2; 9.7.8; 9.7.8.2)","VW 75205:2019-11 (p. 11.5.1.1; 11.5.1.2)","VW 75205:2023-05 (p. 11.5.1.1; 11.5.1.2)","VW 75205:2024-04 (p. 11.6.1.1; 11.6.1.2)","VW 75209-1:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1)","VW 75209-1:2021-12 (p. 9.7.5; 9.7.5.2; 9.7.4; 9.7.6; 9.7.6.2)","VW 75209-2:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1)","VW 75209-2:2021-12 (p.9.7.4; 9.7.5.2; 9.7.3; 9.7.6; 9.7.6.2; 9.7.5)","VW 75210-1:2023-06 (p. 9.7.6; 9.7.6.1; 9.7.6.2; 9.7.7; 9.7.8; 9.7.8.1)","VW 75210-1:2024-08 (p. 9.7.6, 9.7.6.1; 9.7.6.2; 9.7.7; 9.7.7.1; 9.7.8; 9.7.8.1)","VW 75210-2:2023-06 (p. 9.7.5; 9.7.6; 9.7.7; 9.7.7.1)","MBN LV 112-1:2016-03 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1)","MBN LV 122:2017-06 (p. 11.5.5; 11.5.5.2)","MBN 50122:2023-07 (p. 13.5.5; 13.5.5.2)","MBN LV 212-1:2017-08 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1)","MBN 50212-1:2023-04 (p. 12.7.5; 12.7.6; 12.7.6.1; 12.7.6.2; 12.7.7; 12.7.7.1; 12.7.7.2)","MBN LV 216-2:2017-07 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1)","GS 95007-1-1:2013-05 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1)","GS 95007-1-2:2013-05 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1)","GS 95007-1-5:2015-07 (p. 11.5.1.1; 11.5.1.2)","GS 95007-3-1:2015-08 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1)","GS 95007-3-2:2015-09 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1)","GS 95007-6-1:2016-03 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1)","GS 95007-6-2:2017-04 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1)","MBN 50112-1:2023-06 (12.6.6.1; 12.6.7.1; 12.6.7.2; 12.6.8.1; 12.6.8.2)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Badania starzeniowe: - długotrwałe starzenie kabla (3000 h) - krótkotrwałe starzenie kabla (240 h) - przeciążenie cieplne kabli - starzenie krótkotrwałe PVC / Aging tests: - long-term heat aging (3000 h) - short-term heat aging (240 h) - thermal overload - short-term heat aging for PVC\nZakres:\nPiec do 200 °C (± 2 °C)\nKomora klimatyczna - 40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging oven up to 200 °C (± 2 °C)\nClimatic chamber -40 °C to 125 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. VW 60306-1:2018-09-01 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | VW 60306-1:2021-10 (p. 9.7.7; 9.7.6.1; 9.7.7.2; 9.7.8; 9.7.8.2) | VW 60306-2:2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | VW 60306-2:2021-11 (p. 9.7.7; 9.7.7.2; 9.7.6.1; 9.7.8; 9.7.8.2) | VW 60306-4:2021-12 (p. 9.7.6.1; 9.7.7; 9.7.7.2; 9.7.8; 9.7.8.2) | VW 75205:2019-11 (p. 11.5.1.1; 11.5.1.2) | VW 75205:2023-05 (p. 11.5.1.1; 11.5.1.2) | VW 75205:2024-04 (p. 11.6.1.1; 11.6.1.2) | VW 75209-1:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | VW 75209-1:2021-12 (p. 9.7.5; 9.7.5.2; 9.7.4; 9.7.6; 9.7.6.2) | VW 75209-2:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | VW 75209-2:2021-12 (p.9.7.4; 9.7.5.2; 9.7.3; 9.7.6; 9.7.6.2; 9.7.5) | VW 75210-1:2023-06 (p. 9.7.6; 9.7.6.1; 9.7.6.2; 9.7.7; 9.7.8; 9.7.8.1) | VW 75210-1:2024-08 (p. 9.7.6, 9.7.6.1; 9.7.6.2; 9.7.7; 9.7.7.1; 9.7.8; 9.7.8.1) | VW 75210-2:2023-06 (p. 9.7.5; 9.7.6; 9.7.7; 9.7.7.1) | MBN LV 112-1:2016-03 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | MBN LV 122:2017-06 (p. 11.5.5; 11.5.5.2) | MBN 50122:2023-07 (p. 13.5.5; 13.5.5.2) | MBN LV 212-1:2017-08 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | MBN 50212-1:2023-04 (p. 12.7.5; 12.7.6; 12.7.6.1; 12.7.6.2; 12.7.7; 12.7.7.1; 12.7.7.2) | MBN LV 216-2:2017-07 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | GS 95007-1-1:2013-05 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | GS 95007-1-2:2013-05 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | GS 95007-1-5:2015-07 (p. 11.5.1.1; 11.5.1.2) | GS 95007-3-1:2015-08 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | GS 95007-3-2:2015-09 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | GS 95007-6-1:2016-03 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | GS 95007-6-2:2017-04 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | MBN 50112-1:2023-06 (12.6.6.1; 12.6.7.1; 12.6.7.2; 12.6.8.1; 12.6.8.2) Kable / Cables Badania starzeniowe: - dlugotrwale starzenie kabla (3000 h) - krotkotrwale starzenie kabla (240 h) - przeciazenie cieplne kabli - starzenie krotkotrwale PVC / Aging tests: - long-term heat aging (3000 h) - short-term heat aging (240 h) - thermal overload - short-term heat aging for PVC\nZakres:\nPiec do 200 °C (± 2 °C)\nKomora klimatyczna - 40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging oven up to 200 °C (± 2 °C)\nClimatic chamber -40 °C to 125 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. VW 60306-1:2018-09-01 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | VW 60306-1:2021-10 (p. 9.7.7; 9.7.6.1; 9.7.7.2; 9.7.8; 9.7.8.2) | VW 60306-2:2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | VW 60306-2:2021-11 (p. 9.7.7; 9.7.7.2; 9.7.6.1; 9.7.8; 9.7.8.2) | VW 60306-4:2021-12 (p. 9.7.6.1; 9.7.7; 9.7.7.2; 9.7.8; 9.7.8.2) | VW 75205:2019-11 (p. 11.5.1.1; 11.5.1.2) | VW 75205:2023-05 (p. 11.5.1.1; 11.5.1.2) | VW 75205:2024-04 (p. 11.6.1.1; 11.6.1.2) | VW 75209-1:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | VW 75209-1:2021-12 (p. 9.7.5; 9.7.5.2; 9.7.4; 9.7.6; 9.7.6.2) | VW 75209-2:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | VW 75209-2:2021-12 (p.9.7.4; 9.7.5.2; 9.7.3; 9.7.6; 9.7.6.2; 9.7.5) | VW 75210-1:2023-06 (p. 9.7.6; 9.7.6.1; 9.7.6.2; 9.7.7; 9.7.8; 9.7.8.1) | VW 75210-1:2024-08 (p. 9.7.6, 9.7.6.1; 9.7.6.2; 9.7.7; 9.7.7.1; 9.7.8; 9.7.8.1) | VW 75210-2:2023-06 (p. 9.7.5; 9.7.6; 9.7.7; 9.7.7.1) | MBN LV 112-1:2016-03 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | MBN LV 122:2017-06 (p. 11.5.5; 11.5.5.2) | MBN 50122:2023-07 (p. 13.5.5; 13.5.5.2) | MBN LV 212-1:2017-08 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | MBN 50212-1:2023-04 (p. 12.7.5; 12.7.6; 12.7.6.1; 12.7.6.2; 12.7.7; 12.7.7.1; 12.7.7.2) | MBN LV 216-2:2017-07 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | GS 95007-1-1:2013-05 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | GS 95007-1-2:2013-05 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | GS 95007-1-5:2015-07 (p. 11.5.1.1; 11.5.1.2) | GS 95007-3-1:2015-08 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | GS 95007-3-2:2015-09 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | GS 95007-6-1:2016-03 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) | GS 95007-6-2:2017-04 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) | MBN 50112-1:2023-06 (12.6.6.1; 12.6.7.1; 12.6.7.2; 12.6.8.1; 12.6.8.2)","categories":["other"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d96b","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Badania starzeniowe: - długotrwałe starzenie kabla (3000 h) - krótkotrwałe starzenie kabla (240 h) - przeciążenie cieplne kabli - starzenie krótkotrwałe PVC / Aging tests: - long-term heat aging (3000 h) - short-term heat aging (240 h) - thermal overload - short-term heat aging for PVC","parameters":[{"name":"Piec","range":"do 200 °C (± 2 °C)"},{"name":"Komora klimatyczna","range":"- 40 °C do 125 °C"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Zakres","range":"0,5 kV do 6 kV D.C."},{"name":"Aging oven","range":"up to 200 °C (± 2 °C)"},{"name":"Climatic chamber","range":"-40 °C to 125 °C"},{"name":"Range","range":"0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Range","range":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"computed":[],"activity":"Badania starzeniowe: - długotrwałe starzenie kabla (3000 h) - krótkotrwałe starzenie kabla (240 h) - przeciążenie cieplne kabli - starzenie krótkotrwałe PVC / Aging tests: - long-term heat aging (3000 h) - short-term heat aging (240 h) - thermal overload - short-term heat aging for PVC\nZakres:\nPiec do 200 °C (± 2 °C)\nKomora klimatyczna - 40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging oven up to 200 °C (± 2 °C)\nClimatic chamber -40 °C to 125 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C.","reference":"MBN 50112-2:2023-05 (p. 12.7.5; 12.7.6; 12.7.7) | MBN 50216-1:2023-07 (p. 12.7.5; 12.7.5.2; 12.7.6; 12.7.6.1; 12.7.6.2; 12.7.7; 12.7.7.1) | MBN 50112-4:2024-06 (p. 12.6; 12.6.7.1; 12.6.8.1)","norm_bases":["MBN 50112-2:2023-05 (p. 12.7.5; 12.7.6; 12.7.7)","MBN 50216-1:2023-07 (p. 12.7.5; 12.7.5.2; 12.7.6; 12.7.6.1; 12.7.6.2; 12.7.7; 12.7.7.1)","MBN 50112-4:2024-06 (p. 12.6; 12.6.7.1; 12.6.8.1)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Badania starzeniowe: - długotrwałe starzenie kabla (3000 h) - krótkotrwałe starzenie kabla (240 h) - przeciążenie cieplne kabli - starzenie krótkotrwałe PVC / Aging tests: - long-term heat aging (3000 h) - short-term heat aging (240 h) - thermal overload - short-term heat aging for PVC\nZakres:\nPiec do 200 °C (± 2 °C)\nKomora klimatyczna - 40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging oven up to 200 °C (± 2 °C)\nClimatic chamber -40 °C to 125 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. MBN 50112-2:2023-05 (p. 12.7.5; 12.7.6; 12.7.7) | MBN 50216-1:2023-07 (p. 12.7.5; 12.7.5.2; 12.7.6; 12.7.6.1; 12.7.6.2; 12.7.7; 12.7.7.1) | MBN 50112-4:2024-06 (p. 12.6; 12.6.7.1; 12.6.8.1) Kable / Cables Badania starzeniowe: - dlugotrwale starzenie kabla (3000 h) - krotkotrwale starzenie kabla (240 h) - przeciazenie cieplne kabli - starzenie krotkotrwale PVC / Aging tests: - long-term heat aging (3000 h) - short-term heat aging (240 h) - thermal overload - short-term heat aging for PVC\nZakres:\nPiec do 200 °C (± 2 °C)\nKomora klimatyczna - 40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging oven up to 200 °C (± 2 °C)\nClimatic chamber -40 °C to 125 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. MBN 50112-2:2023-05 (p. 12.7.5; 12.7.6; 12.7.7) | MBN 50216-1:2023-07 (p. 12.7.5; 12.7.5.2; 12.7.6; 12.7.6.1; 12.7.6.2; 12.7.7; 12.7.7.1) | MBN 50112-4:2024-06 (p. 12.6; 12.6.7.1; 12.6.8.1)","categories":["other"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d96c","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Odporność izolacji / powłoki kabla na nacisk w wysokiej temperaturze / Pressure test at high temperature","parameters":[{"name":"Piec","range":"do 200°C (± 2°C)"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Zakres","range":"0,5 kV do 6 kV D.C."},{"name":"Aging oven","range":"up to 200 °C (± 2 °C)"},{"name":"Range","range":"0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Range","range":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność izolacji / powłoki kabla na nacisk w wysokiej temperaturze / Pressure test at high temperature\nZakres:\nPiec do 200°C (± 2°C)\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging oven up to 200 °C (± 2 °C)\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C.","reference":"IEC 60811-508:2012 (p. 4.4) | IEC 60811-508:2012-03/AMD1:2017-07 (p. 4.4.1) | IEC 60811-508:2012-03/AMD2:2023-11 (p. 4.4) | ISO 19642-2:2019-01 (p. 5.4.5; 6.4.5) | ISO 19642-2:2023 (p. 5.5.5; 6.5.5) | ISO 19642-3:2019-01 (p. 5.5.5) | ISO 19642-4:2019-01 (p. 5.5.5) | ISO 19642-5:2019-01 (p. 5.5.5) | ISO 19642-6:2019-01 (p. 5.5.5) | ISO 19642-7:2019-01 (p. 6.5.5) | ISO 19642-8:2019-01 (p. 6.5.5) | ISO 19642-9:2019-01 (p. 6.5.5) | ISO 19642-10:2019-01 (p. 6.5.5) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.8) | ISO 6722-2:2013-12-01 (p. 5.8) | ISO 14572:2011-10 (p. 5.7) | LV 112-1:2013-04 (p. 9.6.3) | LV 112-1:2014-04 (p. 9.6.3) | LV 112-2:2007-11 (p. 8.7.3) | LV 112-2:2013-04 (p. 9.6.3) | LV 212-1:2015-01 (p. 9.6.3) | LV 212-2:2015-01 (p. 9.6.3) | LV 216-1:2015-07 (p. 9.6.3) | LV 216-2:2017-02 (p. 9.6.3) | VW 60306-1:2018-09-01 (p. 9.6.3) | VW 60306-1:2021-10 (p. 9.7.3) | VW 60306-2:2013-04 (p. 9.6.3) | VW 60306-2:2021-11 (p. 9.7.3) | VW 60306-4:2021-12 (p. 9.7.3) | VW 75209-1:2015-01 (p. 9.6.3) | VW 75209-1:2021-12 (p. 9.7.2)","norm_bases":["IEC 60811-508:2012 (p. 4.4)","IEC 60811-508:2012-03/AMD1:2017-07 (p. 4.4.1)","IEC 60811-508:2012-03/AMD2:2023-11 (p. 4.4)","ISO 19642-2:2019-01 (p. 5.4.5; 6.4.5)","ISO 19642-2:2023 (p. 5.5.5; 6.5.5)","ISO 19642-3:2019-01 (p. 5.5.5)","ISO 19642-4:2019-01 (p. 5.5.5)","ISO 19642-5:2019-01 (p. 5.5.5)","ISO 19642-6:2019-01 (p. 5.5.5)","ISO 19642-7:2019-01 (p. 6.5.5)","ISO 19642-8:2019-01 (p. 6.5.5)","ISO 19642-9:2019-01 (p. 6.5.5)","ISO 19642-10:2019-01 (p. 6.5.5)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.8)","ISO 6722-2:2013-12-01 (p. 5.8)","ISO 14572:2011-10 (p. 5.7)","LV 112-1:2013-04 (p. 9.6.3)","LV 112-1:2014-04 (p. 9.6.3)","LV 112-2:2007-11 (p. 8.7.3)","LV 112-2:2013-04 (p. 9.6.3)","LV 212-1:2015-01 (p. 9.6.3)","LV 212-2:2015-01 (p. 9.6.3)","LV 216-1:2015-07 (p. 9.6.3)","LV 216-2:2017-02 (p. 9.6.3)","VW 60306-1:2018-09-01 (p. 9.6.3)","VW 60306-1:2021-10 (p. 9.7.3)","VW 60306-2:2013-04 (p. 9.6.3)","VW 60306-2:2021-11 (p. 9.7.3)","VW 60306-4:2021-12 (p. 9.7.3)","VW 75209-1:2015-01 (p. 9.6.3)","VW 75209-1:2021-12 (p. 9.7.2)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Odporność izolacji / powłoki kabla na nacisk w wysokiej temperaturze / Pressure test at high temperature\nZakres:\nPiec do 200°C (± 2°C)\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging oven up to 200 °C (± 2 °C)\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. IEC 60811-508:2012 (p. 4.4) | IEC 60811-508:2012-03/AMD1:2017-07 (p. 4.4.1) | IEC 60811-508:2012-03/AMD2:2023-11 (p. 4.4) | ISO 19642-2:2019-01 (p. 5.4.5; 6.4.5) | ISO 19642-2:2023 (p. 5.5.5; 6.5.5) | ISO 19642-3:2019-01 (p. 5.5.5) | ISO 19642-4:2019-01 (p. 5.5.5) | ISO 19642-5:2019-01 (p. 5.5.5) | ISO 19642-6:2019-01 (p. 5.5.5) | ISO 19642-7:2019-01 (p. 6.5.5) | ISO 19642-8:2019-01 (p. 6.5.5) | ISO 19642-9:2019-01 (p. 6.5.5) | ISO 19642-10:2019-01 (p. 6.5.5) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.8) | ISO 6722-2:2013-12-01 (p. 5.8) | ISO 14572:2011-10 (p. 5.7) | LV 112-1:2013-04 (p. 9.6.3) | LV 112-1:2014-04 (p. 9.6.3) | LV 112-2:2007-11 (p. 8.7.3) | LV 112-2:2013-04 (p. 9.6.3) | LV 212-1:2015-01 (p. 9.6.3) | LV 212-2:2015-01 (p. 9.6.3) | LV 216-1:2015-07 (p. 9.6.3) | LV 216-2:2017-02 (p. 9.6.3) | VW 60306-1:2018-09-01 (p. 9.6.3) | VW 60306-1:2021-10 (p. 9.7.3) | VW 60306-2:2013-04 (p. 9.6.3) | VW 60306-2:2021-11 (p. 9.7.3) | VW 60306-4:2021-12 (p. 9.7.3) | VW 75209-1:2015-01 (p. 9.6.3) | VW 75209-1:2021-12 (p. 9.7.2) Kable / Cables Odpornosc izolacji / powloki kabla na nacisk w wysokiej temperaturze / Pressure test at high temperature\nZakres:\nPiec do 200°C (± 2°C)\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging oven up to 200 °C (± 2 °C)\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. IEC 60811-508:2012 (p. 4.4) | IEC 60811-508:2012-03/AMD1:2017-07 (p. 4.4.1) | IEC 60811-508:2012-03/AMD2:2023-11 (p. 4.4) | ISO 19642-2:2019-01 (p. 5.4.5; 6.4.5) | ISO 19642-2:2023 (p. 5.5.5; 6.5.5) | ISO 19642-3:2019-01 (p. 5.5.5) | ISO 19642-4:2019-01 (p. 5.5.5) | ISO 19642-5:2019-01 (p. 5.5.5) | ISO 19642-6:2019-01 (p. 5.5.5) | ISO 19642-7:2019-01 (p. 6.5.5) | ISO 19642-8:2019-01 (p. 6.5.5) | ISO 19642-9:2019-01 (p. 6.5.5) | ISO 19642-10:2019-01 (p. 6.5.5) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.8) | ISO 6722-2:2013-12-01 (p. 5.8) | ISO 14572:2011-10 (p. 5.7) | LV 112-1:2013-04 (p. 9.6.3) | LV 112-1:2014-04 (p. 9.6.3) | LV 112-2:2007-11 (p. 8.7.3) | LV 112-2:2013-04 (p. 9.6.3) | LV 212-1:2015-01 (p. 9.6.3) | LV 212-2:2015-01 (p. 9.6.3) | LV 216-1:2015-07 (p. 9.6.3) | LV 216-2:2017-02 (p. 9.6.3) | VW 60306-1:2018-09-01 (p. 9.6.3) | VW 60306-1:2021-10 (p. 9.7.3) | VW 60306-2:2013-04 (p. 9.6.3) | VW 60306-2:2021-11 (p. 9.7.3) | VW 60306-4:2021-12 (p. 9.7.3) | VW 75209-1:2015-01 (p. 9.6.3) | VW 75209-1:2021-12 (p. 9.7.2)","categories":["construction"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d96d","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Odporność izolacji / powłoki kabla na nacisk w wysokiej temperaturze / Pressure test at high temperature","parameters":[{"name":"Piec","range":"do 200°C (± 2°C)"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Zakres","range":"0,5 kV do 6 kV D.C."},{"name":"Aging oven","range":"up to 200 °C (± 2 °C)"},{"name":"Range","range":"0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Range","range":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność izolacji / powłoki kabla na nacisk w wysokiej temperaturze / Pressure test at high temperature\nZakres:\nPiec do 200°C (± 2°C)\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging oven up to 200 °C (± 2 °C)\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C.","reference":"VW 75209-2:2015-01 (p. 9.6.3) | VW 75209-2:2021-12 (p. 9.7.1) | VW 75210-1:2023-06 (p. 9.7.3) | VW 75210-1:2024-08 (p. 9.7.3) | VW 75210-2:2023-06 (p. 9.7.3) | MBN LV 112-1:2016-03 (p. 9.6.3) | MBN 50112-1:2023-06 (p. 12.6.3) | MBN LV 112-2:2012-01 (p. 8.7.3) | MBN 50112-2:2023-05 (p. 12.7.3) | MBN 50216-1:2023-07 (p. 12.7.3) | MBN LV 212-1:2017-08 (p. 9.6.3) | MBN 50212-1:2023-04 (p. 12.7.3) | MBN LV 216-2:2017-07 (p. 9.6.3) | MBN 50112-4:2024-06 (p. 12.6.3) | GS 95007-1-1:2013-05 (p. 9.6.3) | GS 95007-1-2:2013-05 (p. 9.6.3) | GS 95007-3-1:2015-08 (p. 9.6.3) | GS 95007-3-2:2015-09 (p. 9.6.3) | GS 95007-6-1:2016-03 (p. 9.6.3) | GS 95007-6-2:2017-04 (p. 9.6.3)","norm_bases":["VW 75209-2:2015-01 (p. 9.6.3)","VW 75209-2:2021-12 (p. 9.7.1)","VW 75210-1:2023-06 (p. 9.7.3)","VW 75210-1:2024-08 (p. 9.7.3)","VW 75210-2:2023-06 (p. 9.7.3)","MBN LV 112-1:2016-03 (p. 9.6.3)","MBN 50112-1:2023-06 (p. 12.6.3)","MBN LV 112-2:2012-01 (p. 8.7.3)","MBN 50112-2:2023-05 (p. 12.7.3)","MBN 50216-1:2023-07 (p. 12.7.3)","MBN LV 212-1:2017-08 (p. 9.6.3)","MBN 50212-1:2023-04 (p. 12.7.3)","MBN LV 216-2:2017-07 (p. 9.6.3)","MBN 50112-4:2024-06 (p. 12.6.3)","GS 95007-1-1:2013-05 (p. 9.6.3)","GS 95007-1-2:2013-05 (p. 9.6.3)","GS 95007-3-1:2015-08 (p. 9.6.3)","GS 95007-3-2:2015-09 (p. 9.6.3)","GS 95007-6-1:2016-03 (p. 9.6.3)","GS 95007-6-2:2017-04 (p. 9.6.3)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Odporność izolacji / powłoki kabla na nacisk w wysokiej temperaturze / Pressure test at high temperature\nZakres:\nPiec do 200°C (± 2°C)\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging oven up to 200 °C (± 2 °C)\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. VW 75209-2:2015-01 (p. 9.6.3) | VW 75209-2:2021-12 (p. 9.7.1) | VW 75210-1:2023-06 (p. 9.7.3) | VW 75210-1:2024-08 (p. 9.7.3) | VW 75210-2:2023-06 (p. 9.7.3) | MBN LV 112-1:2016-03 (p. 9.6.3) | MBN 50112-1:2023-06 (p. 12.6.3) | MBN LV 112-2:2012-01 (p. 8.7.3) | MBN 50112-2:2023-05 (p. 12.7.3) | MBN 50216-1:2023-07 (p. 12.7.3) | MBN LV 212-1:2017-08 (p. 9.6.3) | MBN 50212-1:2023-04 (p. 12.7.3) | MBN LV 216-2:2017-07 (p. 9.6.3) | MBN 50112-4:2024-06 (p. 12.6.3) | GS 95007-1-1:2013-05 (p. 9.6.3) | GS 95007-1-2:2013-05 (p. 9.6.3) | GS 95007-3-1:2015-08 (p. 9.6.3) | GS 95007-3-2:2015-09 (p. 9.6.3) | GS 95007-6-1:2016-03 (p. 9.6.3) | GS 95007-6-2:2017-04 (p. 9.6.3) Kable / Cables Odpornosc izolacji / powloki kabla na nacisk w wysokiej temperaturze / Pressure test at high temperature\nZakres:\nPiec do 200°C (± 2°C)\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging oven up to 200 °C (± 2 °C)\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. VW 75209-2:2015-01 (p. 9.6.3) | VW 75209-2:2021-12 (p. 9.7.1) | VW 75210-1:2023-06 (p. 9.7.3) | VW 75210-1:2024-08 (p. 9.7.3) | VW 75210-2:2023-06 (p. 9.7.3) | MBN LV 112-1:2016-03 (p. 9.6.3) | MBN 50112-1:2023-06 (p. 12.6.3) | MBN LV 112-2:2012-01 (p. 8.7.3) | MBN 50112-2:2023-05 (p. 12.7.3) | MBN 50216-1:2023-07 (p. 12.7.3) | MBN LV 212-1:2017-08 (p. 9.6.3) | MBN 50212-1:2023-04 (p. 12.7.3) | MBN LV 216-2:2017-07 (p. 9.6.3) | MBN 50112-4:2024-06 (p. 12.6.3) | GS 95007-1-1:2013-05 (p. 9.6.3) | GS 95007-1-2:2013-05 (p. 9.6.3) | GS 95007-3-1:2015-08 (p. 9.6.3) | GS 95007-3-2:2015-09 (p. 9.6.3) | GS 95007-6-1:2016-03 (p. 9.6.3) | GS 95007-6-2:2017-04 (p. 9.6.3)","categories":["construction"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d96e","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Skurcz izolacji / powłoki kabla pod wpływem ciepła / Cable insulation / sheath shrinkage under heat","parameters":[{"name":"Piec","range":"do 200°C (± 2°C)"},{"name":"Aging oven","range":"up to 200 °C (± 2 °C)"}],"technique":null,"techniques":[],"computed":[],"activity":"Skurcz izolacji / powłoki kabla pod wpływem ciepła / Cable insulation / sheath shrinkage under heat\nZakres:\nPiec do 200°C (± 2°C)\nAging oven up to 200 °C (± 2 °C)","reference":"ISO 19642-2:2019-01 (p. 5.4.6; 6.4.6) | ISO 19642-2:2023 (p. 5.5.6; 6.5.6) | ISO 19642-3:2019-01 (p. 5.5.6) | ISO 19642-4:2019-01 (p. 5.5.6) | ISO 19642-5:2019-01 (p. 5.5.6) | ISO 19642-6:2019-01 (p. 5.5.6) | ISO 19642-7:2019-01 (p. 6.5.6) | ISO 19642-8:2019-01 (p. 6.5.6) | ISO 19642-9:2019-01 (p. 6.5.6) | ISO 19642-10:2019-01 (p. 6.5.6) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.16) | ISO 6722-2:2013-12-01 (p. 5.16) | ISO 14572:2011-10 (p. 5.16) | LV 112-1:2013-04 (p. 9.6.2) | LV 112-1:2014-04 (p. 9.6.2) | LV 112-2:2007-11 (p. 8.7.2) | LV 112-2:2013-04 (p. 9.6.2) | LV 212-1:2015-01 (p. 9.6.2) | LV 212-2:2015-01 (p. 9.6.2) | LV 216-1:2015-07 (p. 9.6.2) | LV 216-2:2017-02 (p. 9.6.2) | VW 60306-1:2018-09-01 (p. 9.6.2) | VW 60306-1:2021-10 (p. 9.7.2) | VW 60306-2:2013-04 (p. 9.6.2) | VW 60306-2:2021-11 (p. 9.7.2) | VW 60306-4:2021-12 (p. 9.7.2) | VW 75209-1:2015-01 (p. 9.6.2) | VW 75209-1:2021-12 (p. 9.7.1) | VW 75209-2:2015-01 (p. 9.6.2) | VW 75209-2:2021-12 (p. 9.7) | VW 75210-1:2023-06 (p. 9.7.2) | VW 75210-1:2024-08 (p. 9.7.2) | VW 75210-2:2023-06 (p. 9.7.2)","norm_bases":["ISO 19642-2:2019-01 (p. 5.4.6; 6.4.6)","ISO 19642-2:2023 (p. 5.5.6; 6.5.6)","ISO 19642-3:2019-01 (p. 5.5.6)","ISO 19642-4:2019-01 (p. 5.5.6)","ISO 19642-5:2019-01 (p. 5.5.6)","ISO 19642-6:2019-01 (p. 5.5.6)","ISO 19642-7:2019-01 (p. 6.5.6)","ISO 19642-8:2019-01 (p. 6.5.6)","ISO 19642-9:2019-01 (p. 6.5.6)","ISO 19642-10:2019-01 (p. 6.5.6)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.16)","ISO 6722-2:2013-12-01 (p. 5.16)","ISO 14572:2011-10 (p. 5.16)","LV 112-1:2013-04 (p. 9.6.2)","LV 112-1:2014-04 (p. 9.6.2)","LV 112-2:2007-11 (p. 8.7.2)","LV 112-2:2013-04 (p. 9.6.2)","LV 212-1:2015-01 (p. 9.6.2)","LV 212-2:2015-01 (p. 9.6.2)","LV 216-1:2015-07 (p. 9.6.2)","LV 216-2:2017-02 (p. 9.6.2)","VW 60306-1:2018-09-01 (p. 9.6.2)","VW 60306-1:2021-10 (p. 9.7.2)","VW 60306-2:2013-04 (p. 9.6.2)","VW 60306-2:2021-11 (p. 9.7.2)","VW 60306-4:2021-12 (p. 9.7.2)","VW 75209-1:2015-01 (p. 9.6.2)","VW 75209-1:2021-12 (p. 9.7.1)","VW 75209-2:2015-01 (p. 9.6.2)","VW 75209-2:2021-12 (p. 9.7)","VW 75210-1:2023-06 (p. 9.7.2)","VW 75210-1:2024-08 (p. 9.7.2)","VW 75210-2:2023-06 (p. 9.7.2)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Skurcz izolacji / powłoki kabla pod wpływem ciepła / Cable insulation / sheath shrinkage under heat\nZakres:\nPiec do 200°C (± 2°C)\nAging oven up to 200 °C (± 2 °C) ISO 19642-2:2019-01 (p. 5.4.6; 6.4.6) | ISO 19642-2:2023 (p. 5.5.6; 6.5.6) | ISO 19642-3:2019-01 (p. 5.5.6) | ISO 19642-4:2019-01 (p. 5.5.6) | ISO 19642-5:2019-01 (p. 5.5.6) | ISO 19642-6:2019-01 (p. 5.5.6) | ISO 19642-7:2019-01 (p. 6.5.6) | ISO 19642-8:2019-01 (p. 6.5.6) | ISO 19642-9:2019-01 (p. 6.5.6) | ISO 19642-10:2019-01 (p. 6.5.6) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.16) | ISO 6722-2:2013-12-01 (p. 5.16) | ISO 14572:2011-10 (p. 5.16) | LV 112-1:2013-04 (p. 9.6.2) | LV 112-1:2014-04 (p. 9.6.2) | LV 112-2:2007-11 (p. 8.7.2) | LV 112-2:2013-04 (p. 9.6.2) | LV 212-1:2015-01 (p. 9.6.2) | LV 212-2:2015-01 (p. 9.6.2) | LV 216-1:2015-07 (p. 9.6.2) | LV 216-2:2017-02 (p. 9.6.2) | VW 60306-1:2018-09-01 (p. 9.6.2) | VW 60306-1:2021-10 (p. 9.7.2) | VW 60306-2:2013-04 (p. 9.6.2) | VW 60306-2:2021-11 (p. 9.7.2) | VW 60306-4:2021-12 (p. 9.7.2) | VW 75209-1:2015-01 (p. 9.6.2) | VW 75209-1:2021-12 (p. 9.7.1) | VW 75209-2:2015-01 (p. 9.6.2) | VW 75209-2:2021-12 (p. 9.7) | VW 75210-1:2023-06 (p. 9.7.2) | VW 75210-1:2024-08 (p. 9.7.2) | VW 75210-2:2023-06 (p. 9.7.2) Kable / Cables Skurcz izolacji / powloki kabla pod wplywem ciepla / Cable insulation / sheath shrinkage under heat\nZakres:\nPiec do 200°C (± 2°C)\nAging oven up to 200 °C (± 2 °C) ISO 19642-2:2019-01 (p. 5.4.6; 6.4.6) | ISO 19642-2:2023 (p. 5.5.6; 6.5.6) | ISO 19642-3:2019-01 (p. 5.5.6) | ISO 19642-4:2019-01 (p. 5.5.6) | ISO 19642-5:2019-01 (p. 5.5.6) | ISO 19642-6:2019-01 (p. 5.5.6) | ISO 19642-7:2019-01 (p. 6.5.6) | ISO 19642-8:2019-01 (p. 6.5.6) | ISO 19642-9:2019-01 (p. 6.5.6) | ISO 19642-10:2019-01 (p. 6.5.6) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.16) | ISO 6722-2:2013-12-01 (p. 5.16) | ISO 14572:2011-10 (p. 5.16) | LV 112-1:2013-04 (p. 9.6.2) | LV 112-1:2014-04 (p. 9.6.2) | LV 112-2:2007-11 (p. 8.7.2) | LV 112-2:2013-04 (p. 9.6.2) | LV 212-1:2015-01 (p. 9.6.2) | LV 212-2:2015-01 (p. 9.6.2) | LV 216-1:2015-07 (p. 9.6.2) | LV 216-2:2017-02 (p. 9.6.2) | VW 60306-1:2018-09-01 (p. 9.6.2) | VW 60306-1:2021-10 (p. 9.7.2) | VW 60306-2:2013-04 (p. 9.6.2) | VW 60306-2:2021-11 (p. 9.7.2) | VW 60306-4:2021-12 (p. 9.7.2) | VW 75209-1:2015-01 (p. 9.6.2) | VW 75209-1:2021-12 (p. 9.7.1) | VW 75209-2:2015-01 (p. 9.6.2) | VW 75209-2:2021-12 (p. 9.7) | VW 75210-1:2023-06 (p. 9.7.2) | VW 75210-1:2024-08 (p. 9.7.2) | VW 75210-2:2023-06 (p. 9.7.2)","categories":["construction"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d96f","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Skurcz izolacji / powłoki kabla pod wpływem ciepła / Cable insulation / sheath shrinkage under heat","parameters":[{"name":"Piec","range":"do 200°C (± 2°C)"},{"name":"Aging oven","range":"up to 200 °C (± 2 °C)"}],"technique":null,"techniques":[],"computed":[],"activity":"Skurcz izolacji / powłoki kabla pod wpływem ciepła / Cable insulation / sheath shrinkage under heat\nZakres:\nPiec do 200°C (± 2°C)\nAging oven up to 200 °C (± 2 °C)","reference":"MBN LV 112-1:2016-03 (p. 9.6.2) | MBN 50112-1:2023-06 (p. 12.6.2) | MBN LV 112-2:2012-01 (p. 8.7.2) | MBN 50112-2:2023-05 (p. 12.7.2) | MBN 50216-1:2023-07 (p. 12.7.2) | MBN LV 212-1:2017-08 (p. 9.6.2) | MBN 50212-1:2023-04 (p. 12.7.2) | MBN LV 216-2:2017-07 (p. 9.6.2) | MBN 50112-4:2024-06 (p. 12.6.2) | GS 95007-1-1:2013-05 (p. 9.6.2) | GS 95007-1-2:2013-05 (p. 9.6.2) | GS 95007-3-1:2015-08 (p. 9.6.2) | GS 95007-3-2:2015-09 (p. 9.6.2) | GS 95007-6-1:2016-03 (p. 9.6.2) | GS 95007-6-2:2017-04 (p. 9.6.2)","norm_bases":["MBN LV 112-1:2016-03 (p. 9.6.2)","MBN 50112-1:2023-06 (p. 12.6.2)","MBN LV 112-2:2012-01 (p. 8.7.2)","MBN 50112-2:2023-05 (p. 12.7.2)","MBN 50216-1:2023-07 (p. 12.7.2)","MBN LV 212-1:2017-08 (p. 9.6.2)","MBN 50212-1:2023-04 (p. 12.7.2)","MBN LV 216-2:2017-07 (p. 9.6.2)","MBN 50112-4:2024-06 (p. 12.6.2)","GS 95007-1-1:2013-05 (p. 9.6.2)","GS 95007-1-2:2013-05 (p. 9.6.2)","GS 95007-3-1:2015-08 (p. 9.6.2)","GS 95007-3-2:2015-09 (p. 9.6.2)","GS 95007-6-1:2016-03 (p. 9.6.2)","GS 95007-6-2:2017-04 (p. 9.6.2)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Skurcz izolacji / powłoki kabla pod wpływem ciepła / Cable insulation / sheath shrinkage under heat\nZakres:\nPiec do 200°C (± 2°C)\nAging oven up to 200 °C (± 2 °C) MBN LV 112-1:2016-03 (p. 9.6.2) | MBN 50112-1:2023-06 (p. 12.6.2) | MBN LV 112-2:2012-01 (p. 8.7.2) | MBN 50112-2:2023-05 (p. 12.7.2) | MBN 50216-1:2023-07 (p. 12.7.2) | MBN LV 212-1:2017-08 (p. 9.6.2) | MBN 50212-1:2023-04 (p. 12.7.2) | MBN LV 216-2:2017-07 (p. 9.6.2) | MBN 50112-4:2024-06 (p. 12.6.2) | GS 95007-1-1:2013-05 (p. 9.6.2) | GS 95007-1-2:2013-05 (p. 9.6.2) | GS 95007-3-1:2015-08 (p. 9.6.2) | GS 95007-3-2:2015-09 (p. 9.6.2) | GS 95007-6-1:2016-03 (p. 9.6.2) | GS 95007-6-2:2017-04 (p. 9.6.2) Kable / Cables Skurcz izolacji / powloki kabla pod wplywem ciepla / Cable insulation / sheath shrinkage under heat\nZakres:\nPiec do 200°C (± 2°C)\nAging oven up to 200 °C (± 2 °C) MBN LV 112-1:2016-03 (p. 9.6.2) | MBN 50112-1:2023-06 (p. 12.6.2) | MBN LV 112-2:2012-01 (p. 8.7.2) | MBN 50112-2:2023-05 (p. 12.7.2) | MBN 50216-1:2023-07 (p. 12.7.2) | MBN LV 212-1:2017-08 (p. 9.6.2) | MBN 50212-1:2023-04 (p. 12.7.2) | MBN LV 216-2:2017-07 (p. 9.6.2) | MBN 50112-4:2024-06 (p. 12.6.2) | GS 95007-1-1:2013-05 (p. 9.6.2) | GS 95007-1-2:2013-05 (p. 9.6.2) | GS 95007-3-1:2015-08 (p. 9.6.2) | GS 95007-3-2:2015-09 (p. 9.6.2) | GS 95007-6-1:2016-03 (p. 9.6.2) | GS 95007-6-2:2017-04 (p. 9.6.2)","categories":["construction"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d970","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Nawijanie kabla w niskiej temperaturze / Low temperature winding","parameters":[{"name":"Komora klimatyczna","range":"-40 °C do 125 °C"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Zakres","range":"0,5 kV do 6 kV D.C."},{"name":"Climatic chamber","range":"-40 °C to 125 °C"},{"name":"Range","range":"0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Range","range":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"computed":[],"activity":"Nawijanie kabla w niskiej temperaturze / Low temperature winding\nZakres:\nKomora klimatyczna -40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nClimatic chamber -40 °C to 125 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C.","reference":"ISO 19642-2:2019-01 (p. 5.4.7; 6.4.7) | ISO 19642-2:2023 (p. 5.5.7; 6.5.7) | ISO 19642-3:2019-01 (p. 5.5.7) | ISO 19642-4:2019-01 (p. 5.5.7) | ISO 19642-5:2019-01 (p. 5.5.7) | ISO 19642-6:2019-01 (p. 5.5.7) | ISO 19642-7:2019-01 (p. 6.5.7) | ISO 19642-8:2019-01 (p. 6.5.7) | ISO 19642-9:2019-01 (p. 6.5.7) | ISO 19642-10:2019-01 (p. 6.5.7) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.10) | ISO 6722-2:2013-12-01 (p. 5.10) | ISO 14572:2011-10 (p. 5.10) | LV 112-1:2013-04 (p. 9.6.9) | LV 112-1:2014-04 (p. 9.6.9) | LV 112-2:2007-11 (p. 8.7.8) | LV 112-2:2013-04 (p. 9.6.9) | LV 122:2015-05 (p. 11.5.2) | LV 122:2016-02 (p. 11.5.6) | LV 212-1:2015-01 (p. 9.6.8) | LV 212-2:2015-01 (p. 9.6.8) | LV 216-1:2015-07 (p. 9.6.9) | LV 216-2:2017-02 (p. 9.6.8) | VW 60306-1:2018-09-01 (p. 9.6.9) | VW 60306-1:2021-10 (p. 9.7.9) | VW 60306-2:2013-04 (p. 9.6.9) | VW 60306-2:2021-11 (p. 9.7.9) | VW 60306-4:2021-12 (p. 9.7.9) | VW 75205:2019-11 (p. 11.5.2) | VW 75205:2023-05 (p. 11.5.2) | VW 75205:2024-04 (p. 11.6.2) | VW 75209-1:2015-01 (p. 9.6.8) | VW 75209-1:2021-12 (p. 9.7.7) | VW 75209-2:2015-01 (p. 9.6.8) | VW 75209-2:2021-12 (p. 9.7.7) | VW 75210-1:2023-06 (p. 9.7.9) | VW 75210-1:2024-08 (p. 9.7.9) | VW 75210-2:2023-06 (p. 9.7.8)","norm_bases":["ISO 19642-2:2019-01 (p. 5.4.7; 6.4.7)","ISO 19642-2:2023 (p. 5.5.7; 6.5.7)","ISO 19642-3:2019-01 (p. 5.5.7)","ISO 19642-4:2019-01 (p. 5.5.7)","ISO 19642-5:2019-01 (p. 5.5.7)","ISO 19642-6:2019-01 (p. 5.5.7)","ISO 19642-7:2019-01 (p. 6.5.7)","ISO 19642-8:2019-01 (p. 6.5.7)","ISO 19642-9:2019-01 (p. 6.5.7)","ISO 19642-10:2019-01 (p. 6.5.7)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.10)","ISO 6722-2:2013-12-01 (p. 5.10)","ISO 14572:2011-10 (p. 5.10)","LV 112-1:2013-04 (p. 9.6.9)","LV 112-1:2014-04 (p. 9.6.9)","LV 112-2:2007-11 (p. 8.7.8)","LV 112-2:2013-04 (p. 9.6.9)","LV 122:2015-05 (p. 11.5.2)","LV 122:2016-02 (p. 11.5.6)","LV 212-1:2015-01 (p. 9.6.8)","LV 212-2:2015-01 (p. 9.6.8)","LV 216-1:2015-07 (p. 9.6.9)","LV 216-2:2017-02 (p. 9.6.8)","VW 60306-1:2018-09-01 (p. 9.6.9)","VW 60306-1:2021-10 (p. 9.7.9)","VW 60306-2:2013-04 (p. 9.6.9)","VW 60306-2:2021-11 (p. 9.7.9)","VW 60306-4:2021-12 (p. 9.7.9)","VW 75205:2019-11 (p. 11.5.2)","VW 75205:2023-05 (p. 11.5.2)","VW 75205:2024-04 (p. 11.6.2)","VW 75209-1:2015-01 (p. 9.6.8)","VW 75209-1:2021-12 (p. 9.7.7)","VW 75209-2:2015-01 (p. 9.6.8)","VW 75209-2:2021-12 (p. 9.7.7)","VW 75210-1:2023-06 (p. 9.7.9)","VW 75210-1:2024-08 (p. 9.7.9)","VW 75210-2:2023-06 (p. 9.7.8)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Nawijanie kabla w niskiej temperaturze / Low temperature winding\nZakres:\nKomora klimatyczna -40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nClimatic chamber -40 °C to 125 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. ISO 19642-2:2019-01 (p. 5.4.7; 6.4.7) | ISO 19642-2:2023 (p. 5.5.7; 6.5.7) | ISO 19642-3:2019-01 (p. 5.5.7) | ISO 19642-4:2019-01 (p. 5.5.7) | ISO 19642-5:2019-01 (p. 5.5.7) | ISO 19642-6:2019-01 (p. 5.5.7) | ISO 19642-7:2019-01 (p. 6.5.7) | ISO 19642-8:2019-01 (p. 6.5.7) | ISO 19642-9:2019-01 (p. 6.5.7) | ISO 19642-10:2019-01 (p. 6.5.7) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.10) | ISO 6722-2:2013-12-01 (p. 5.10) | ISO 14572:2011-10 (p. 5.10) | LV 112-1:2013-04 (p. 9.6.9) | LV 112-1:2014-04 (p. 9.6.9) | LV 112-2:2007-11 (p. 8.7.8) | LV 112-2:2013-04 (p. 9.6.9) | LV 122:2015-05 (p. 11.5.2) | LV 122:2016-02 (p. 11.5.6) | LV 212-1:2015-01 (p. 9.6.8) | LV 212-2:2015-01 (p. 9.6.8) | LV 216-1:2015-07 (p. 9.6.9) | LV 216-2:2017-02 (p. 9.6.8) | VW 60306-1:2018-09-01 (p. 9.6.9) | VW 60306-1:2021-10 (p. 9.7.9) | VW 60306-2:2013-04 (p. 9.6.9) | VW 60306-2:2021-11 (p. 9.7.9) | VW 60306-4:2021-12 (p. 9.7.9) | VW 75205:2019-11 (p. 11.5.2) | VW 75205:2023-05 (p. 11.5.2) | VW 75205:2024-04 (p. 11.6.2) | VW 75209-1:2015-01 (p. 9.6.8) | VW 75209-1:2021-12 (p. 9.7.7) | VW 75209-2:2015-01 (p. 9.6.8) | VW 75209-2:2021-12 (p. 9.7.7) | VW 75210-1:2023-06 (p. 9.7.9) | VW 75210-1:2024-08 (p. 9.7.9) | VW 75210-2:2023-06 (p. 9.7.8) Kable / Cables Nawijanie kabla w niskiej temperaturze / Low temperature winding\nZakres:\nKomora klimatyczna -40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nClimatic chamber -40 °C to 125 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. ISO 19642-2:2019-01 (p. 5.4.7; 6.4.7) | ISO 19642-2:2023 (p. 5.5.7; 6.5.7) | ISO 19642-3:2019-01 (p. 5.5.7) | ISO 19642-4:2019-01 (p. 5.5.7) | ISO 19642-5:2019-01 (p. 5.5.7) | ISO 19642-6:2019-01 (p. 5.5.7) | ISO 19642-7:2019-01 (p. 6.5.7) | ISO 19642-8:2019-01 (p. 6.5.7) | ISO 19642-9:2019-01 (p. 6.5.7) | ISO 19642-10:2019-01 (p. 6.5.7) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.10) | ISO 6722-2:2013-12-01 (p. 5.10) | ISO 14572:2011-10 (p. 5.10) | LV 112-1:2013-04 (p. 9.6.9) | LV 112-1:2014-04 (p. 9.6.9) | LV 112-2:2007-11 (p. 8.7.8) | LV 112-2:2013-04 (p. 9.6.9) | LV 122:2015-05 (p. 11.5.2) | LV 122:2016-02 (p. 11.5.6) | LV 212-1:2015-01 (p. 9.6.8) | LV 212-2:2015-01 (p. 9.6.8) | LV 216-1:2015-07 (p. 9.6.9) | LV 216-2:2017-02 (p. 9.6.8) | VW 60306-1:2018-09-01 (p. 9.6.9) | VW 60306-1:2021-10 (p. 9.7.9) | VW 60306-2:2013-04 (p. 9.6.9) | VW 60306-2:2021-11 (p. 9.7.9) | VW 60306-4:2021-12 (p. 9.7.9) | VW 75205:2019-11 (p. 11.5.2) | VW 75205:2023-05 (p. 11.5.2) | VW 75205:2024-04 (p. 11.6.2) | VW 75209-1:2015-01 (p. 9.6.8) | VW 75209-1:2021-12 (p. 9.7.7) | VW 75209-2:2015-01 (p. 9.6.8) | VW 75209-2:2021-12 (p. 9.7.7) | VW 75210-1:2023-06 (p. 9.7.9) | VW 75210-1:2024-08 (p. 9.7.9) | VW 75210-2:2023-06 (p. 9.7.8)","categories":["other"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d971","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Nawijanie kabla w niskiej temperaturze / Low temperature winding","parameters":[{"name":"Komora klimatyczna","range":"-40 °C do 125 °C"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Zakres","range":"0,5 kV do 6 kV D.C."},{"name":"Climatic chamber","range":"-40 °C to 125 °C"},{"name":"Range","range":"0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Range","range":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"computed":[],"activity":"Nawijanie kabla w niskiej temperaturze / Low temperature winding\nZakres:\nKomora klimatyczna -40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nClimatic chamber -40 °C to 125 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C.","reference":"MBN LV 112-1:2016-03 (p. 9.6.9) | MBN 50112-1:2023-06 (p. 12.6.9) | MBN LV 112-2:2012-01 (p. 8.7.8) | MBN 50112-2:2023-05 (p. 12.7.8) | MBN 50216-1:2023-07 (p. 12.7.8) | MBN LV 122:2017-06 (p. 11.5.6) | MBN 50122:2023-07 (p. 13.5.6) | MBN LV 212-1:2017-08 (p. 9.6.8) | MBN 50212-1:2023-04 (p. 12.7.8) | MBN LV 216-2:2017-07 (p. 9.6.8) | MBN 50112-4:2024-06 (p. 12.6.9) | GS 95007-1-1:2013-05 (p. 9.6.9) | GS 95007-1-2:2013-05 (p. 9.6.9) | GS 95007-1-5:2015-07 (p. 11.5.2) | GS 95007-3-1:2015-08 (p. 9.6.8) | GS 95007-3-2:2015-09 (p. 9.6.8) | GS 95007-6-1:2016-03 (p. 9.6.9) | GS 95007-6-2:2017-04 (p. 9.6.8)","norm_bases":["MBN LV 112-1:2016-03 (p. 9.6.9)","MBN 50112-1:2023-06 (p. 12.6.9)","MBN LV 112-2:2012-01 (p. 8.7.8)","MBN 50112-2:2023-05 (p. 12.7.8)","MBN 50216-1:2023-07 (p. 12.7.8)","MBN LV 122:2017-06 (p. 11.5.6)","MBN 50122:2023-07 (p. 13.5.6)","MBN LV 212-1:2017-08 (p. 9.6.8)","MBN 50212-1:2023-04 (p. 12.7.8)","MBN LV 216-2:2017-07 (p. 9.6.8)","MBN 50112-4:2024-06 (p. 12.6.9)","GS 95007-1-1:2013-05 (p. 9.6.9)","GS 95007-1-2:2013-05 (p. 9.6.9)","GS 95007-1-5:2015-07 (p. 11.5.2)","GS 95007-3-1:2015-08 (p. 9.6.8)","GS 95007-3-2:2015-09 (p. 9.6.8)","GS 95007-6-1:2016-03 (p. 9.6.9)","GS 95007-6-2:2017-04 (p. 9.6.8)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Nawijanie kabla w niskiej temperaturze / Low temperature winding\nZakres:\nKomora klimatyczna -40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nClimatic chamber -40 °C to 125 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. MBN LV 112-1:2016-03 (p. 9.6.9) | MBN 50112-1:2023-06 (p. 12.6.9) | MBN LV 112-2:2012-01 (p. 8.7.8) | MBN 50112-2:2023-05 (p. 12.7.8) | MBN 50216-1:2023-07 (p. 12.7.8) | MBN LV 122:2017-06 (p. 11.5.6) | MBN 50122:2023-07 (p. 13.5.6) | MBN LV 212-1:2017-08 (p. 9.6.8) | MBN 50212-1:2023-04 (p. 12.7.8) | MBN LV 216-2:2017-07 (p. 9.6.8) | MBN 50112-4:2024-06 (p. 12.6.9) | GS 95007-1-1:2013-05 (p. 9.6.9) | GS 95007-1-2:2013-05 (p. 9.6.9) | GS 95007-1-5:2015-07 (p. 11.5.2) | GS 95007-3-1:2015-08 (p. 9.6.8) | GS 95007-3-2:2015-09 (p. 9.6.8) | GS 95007-6-1:2016-03 (p. 9.6.9) | GS 95007-6-2:2017-04 (p. 9.6.8) Kable / Cables Nawijanie kabla w niskiej temperaturze / Low temperature winding\nZakres:\nKomora klimatyczna -40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nClimatic chamber -40 °C to 125 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. MBN LV 112-1:2016-03 (p. 9.6.9) | MBN 50112-1:2023-06 (p. 12.6.9) | MBN LV 112-2:2012-01 (p. 8.7.8) | MBN 50112-2:2023-05 (p. 12.7.8) | MBN 50216-1:2023-07 (p. 12.7.8) | MBN LV 122:2017-06 (p. 11.5.6) | MBN 50122:2023-07 (p. 13.5.6) | MBN LV 212-1:2017-08 (p. 9.6.8) | MBN 50212-1:2023-04 (p. 12.7.8) | MBN LV 216-2:2017-07 (p. 9.6.8) | MBN 50112-4:2024-06 (p. 12.6.9) | GS 95007-1-1:2013-05 (p. 9.6.9) | GS 95007-1-2:2013-05 (p. 9.6.9) | GS 95007-1-5:2015-07 (p. 11.5.2) | GS 95007-3-1:2015-08 (p. 9.6.8) | GS 95007-3-2:2015-09 (p. 9.6.8) | GS 95007-6-1:2016-03 (p. 9.6.9) | GS 95007-6-2:2017-04 (p. 9.6.8)","categories":["other"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d972","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Uderzenie kabla w niskiej temperaturze / Cold impact","parameters":[{"name":"Komora klimatyczna","range":"-40 °C do 175 °C"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Zakres","range":"0,5 kV do 6 kV D.C."},{"name":"Climatic chamber","range":"-40 °C to 175 °C"},{"name":"Range","range":"0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Range","range":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"computed":[],"activity":"Uderzenie kabla w niskiej temperaturze / Cold impact\nZakres:\nKomora klimatyczna -40 °C do 175 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nClimatic chamber -40 °C to 175 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C.","reference":"ISO 19642-2:2019-01 (p. 5.4.8; 6.4.8) | ISO 19642-2:2023 (p. 5.5.8; 6.5.8) | ISO 19642-3:2019-01 (p. 5.5.8) | ISO 19642-4:2019-01 (p. 5.5.8) | ISO 19642-5:2019-01 (p. 5.5.8) | ISO 19642-6:2019-01 (p. 5.5.8) | ISO 19642-7:2019-01 (p. 6.5.8) | ISO 19642-8:2019-01 (p. 6.5.8) | ISO 19642-9:2019-01 (p. 6.5.8) | ISO 19642-10:2019-01 (p. 6.5.8) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.11) | ISO 6722-2:2013-12-01 (p. 5.11) | ISO 14572:2011-10 (p. 5.11) | LV 112-1:2013-04 (p. 9.6.10) | LV 112-1:2014-04 (p. 9.6.10) | LV 112-2:2007-11 (p. 8.7.9) | LV 112-2:2013-04 (p. 9.6.10) | LV 212-1:2015-01 (p. 9.6.9) | LV 212-2:2015-01 (p. 9.6.9) | LV 216-1:2015-07 (p. 9.6.10) | LV 216-2:2017-02 (p. 9.6.9) | VW 60306-1:2018-09-01 (p. 9.6.10) | VW 60306-1:2021-10 (p. 9.7.10) | VW 60306-2:2013-04 (p. 9.6.10) | VW 60306-2:2021-11 (p. 9.7.10) | VW 60306-4:2021-12 (p. 9.7.10) | VW 75209-1:2015-01 (p. 9.6.9) | VW 75209-1:2021-12 (p. 9.7.8) | VW 75209-2:2015-01 (p. 9.6.9) | VW 75209-2:2021-12 (p. 9.7.8) | VW 75210-1:2023-06 (p. 9.7.10) | VW 75210-1:2024-08 (p. 9.7.10) | VW 75210-2:2023-06 (p. 9.7.9) | MBN LV 112-1:2016-03 (p. 9.6.10) | MBN 50112-1:2023-06 (p. 12.6.10)","norm_bases":["ISO 19642-2:2019-01 (p. 5.4.8; 6.4.8)","ISO 19642-2:2023 (p. 5.5.8; 6.5.8)","ISO 19642-3:2019-01 (p. 5.5.8)","ISO 19642-4:2019-01 (p. 5.5.8)","ISO 19642-5:2019-01 (p. 5.5.8)","ISO 19642-6:2019-01 (p. 5.5.8)","ISO 19642-7:2019-01 (p. 6.5.8)","ISO 19642-8:2019-01 (p. 6.5.8)","ISO 19642-9:2019-01 (p. 6.5.8)","ISO 19642-10:2019-01 (p. 6.5.8)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.11)","ISO 6722-2:2013-12-01 (p. 5.11)","ISO 14572:2011-10 (p. 5.11)","LV 112-1:2013-04 (p. 9.6.10)","LV 112-1:2014-04 (p. 9.6.10)","LV 112-2:2007-11 (p. 8.7.9)","LV 112-2:2013-04 (p. 9.6.10)","LV 212-1:2015-01 (p. 9.6.9)","LV 212-2:2015-01 (p. 9.6.9)","LV 216-1:2015-07 (p. 9.6.10)","LV 216-2:2017-02 (p. 9.6.9)","VW 60306-1:2018-09-01 (p. 9.6.10)","VW 60306-1:2021-10 (p. 9.7.10)","VW 60306-2:2013-04 (p. 9.6.10)","VW 60306-2:2021-11 (p. 9.7.10)","VW 60306-4:2021-12 (p. 9.7.10)","VW 75209-1:2015-01 (p. 9.6.9)","VW 75209-1:2021-12 (p. 9.7.8)","VW 75209-2:2015-01 (p. 9.6.9)","VW 75209-2:2021-12 (p. 9.7.8)","VW 75210-1:2023-06 (p. 9.7.10)","VW 75210-1:2024-08 (p. 9.7.10)","VW 75210-2:2023-06 (p. 9.7.9)","MBN LV 112-1:2016-03 (p. 9.6.10)","MBN 50112-1:2023-06 (p. 12.6.10)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Uderzenie kabla w niskiej temperaturze / Cold impact\nZakres:\nKomora klimatyczna -40 °C do 175 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nClimatic chamber -40 °C to 175 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. ISO 19642-2:2019-01 (p. 5.4.8; 6.4.8) | ISO 19642-2:2023 (p. 5.5.8; 6.5.8) | ISO 19642-3:2019-01 (p. 5.5.8) | ISO 19642-4:2019-01 (p. 5.5.8) | ISO 19642-5:2019-01 (p. 5.5.8) | ISO 19642-6:2019-01 (p. 5.5.8) | ISO 19642-7:2019-01 (p. 6.5.8) | ISO 19642-8:2019-01 (p. 6.5.8) | ISO 19642-9:2019-01 (p. 6.5.8) | ISO 19642-10:2019-01 (p. 6.5.8) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.11) | ISO 6722-2:2013-12-01 (p. 5.11) | ISO 14572:2011-10 (p. 5.11) | LV 112-1:2013-04 (p. 9.6.10) | LV 112-1:2014-04 (p. 9.6.10) | LV 112-2:2007-11 (p. 8.7.9) | LV 112-2:2013-04 (p. 9.6.10) | LV 212-1:2015-01 (p. 9.6.9) | LV 212-2:2015-01 (p. 9.6.9) | LV 216-1:2015-07 (p. 9.6.10) | LV 216-2:2017-02 (p. 9.6.9) | VW 60306-1:2018-09-01 (p. 9.6.10) | VW 60306-1:2021-10 (p. 9.7.10) | VW 60306-2:2013-04 (p. 9.6.10) | VW 60306-2:2021-11 (p. 9.7.10) | VW 60306-4:2021-12 (p. 9.7.10) | VW 75209-1:2015-01 (p. 9.6.9) | VW 75209-1:2021-12 (p. 9.7.8) | VW 75209-2:2015-01 (p. 9.6.9) | VW 75209-2:2021-12 (p. 9.7.8) | VW 75210-1:2023-06 (p. 9.7.10) | VW 75210-1:2024-08 (p. 9.7.10) | VW 75210-2:2023-06 (p. 9.7.9) | MBN LV 112-1:2016-03 (p. 9.6.10) | MBN 50112-1:2023-06 (p. 12.6.10) Kable / Cables Uderzenie kabla w niskiej temperaturze / Cold impact\nZakres:\nKomora klimatyczna -40 °C do 175 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nClimatic chamber -40 °C to 175 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. ISO 19642-2:2019-01 (p. 5.4.8; 6.4.8) | ISO 19642-2:2023 (p. 5.5.8; 6.5.8) | ISO 19642-3:2019-01 (p. 5.5.8) | ISO 19642-4:2019-01 (p. 5.5.8) | ISO 19642-5:2019-01 (p. 5.5.8) | ISO 19642-6:2019-01 (p. 5.5.8) | ISO 19642-7:2019-01 (p. 6.5.8) | ISO 19642-8:2019-01 (p. 6.5.8) | ISO 19642-9:2019-01 (p. 6.5.8) | ISO 19642-10:2019-01 (p. 6.5.8) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.11) | ISO 6722-2:2013-12-01 (p. 5.11) | ISO 14572:2011-10 (p. 5.11) | LV 112-1:2013-04 (p. 9.6.10) | LV 112-1:2014-04 (p. 9.6.10) | LV 112-2:2007-11 (p. 8.7.9) | LV 112-2:2013-04 (p. 9.6.10) | LV 212-1:2015-01 (p. 9.6.9) | LV 212-2:2015-01 (p. 9.6.9) | LV 216-1:2015-07 (p. 9.6.10) | LV 216-2:2017-02 (p. 9.6.9) | VW 60306-1:2018-09-01 (p. 9.6.10) | VW 60306-1:2021-10 (p. 9.7.10) | VW 60306-2:2013-04 (p. 9.6.10) | VW 60306-2:2021-11 (p. 9.7.10) | VW 60306-4:2021-12 (p. 9.7.10) | VW 75209-1:2015-01 (p. 9.6.9) | VW 75209-1:2021-12 (p. 9.7.8) | VW 75209-2:2015-01 (p. 9.6.9) | VW 75209-2:2021-12 (p. 9.7.8) | VW 75210-1:2023-06 (p. 9.7.10) | VW 75210-1:2024-08 (p. 9.7.10) | VW 75210-2:2023-06 (p. 9.7.9) | MBN LV 112-1:2016-03 (p. 9.6.10) | MBN 50112-1:2023-06 (p. 12.6.10)","categories":["other"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d973","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Uderzenie kabla w niskiej temperaturze / Cold impact","parameters":[{"name":"Komora klimatyczna","range":"-40 °C do 175 °C"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Zakres","range":"0,5 kV do 6 kV D.C."},{"name":"Climatic chamber","range":"-40 °C to 175 °C"},{"name":"Range","range":"0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Range","range":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"computed":[],"activity":"Uderzenie kabla w niskiej temperaturze / Cold impact\nZakres:\nKomora klimatyczna -40 °C do 175 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nClimatic chamber -40 °C to 175 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C.","reference":"MBN LV 112-2:2012-01 (p. 8.7.9) | MBN 50112-2:2023-05 (p. 12.7.9) | MBN 50216-1:2023-07 (p. 12.7.9) | MBN LV 212-1:2017-08 (p. 9.6.9) | MBN 50212-1:2023-04 (p. 12.7.9) | MBN LV 216-2:2017-07 (p. 9.6.9) | MBN 50112-4:2024-06 (p. 12.6.10) | GS 95007-1-1:2013-05 (p. 9.6.10) | GS 95007-1-2:2013-05 (p. 9.6.10) | GS 95007-3-1:2015-08 (p. 9.6.9) | GS 95007-3-2:2015-09 (p. 9.6.9) | GS 95007-6-1:2016-03 (p. 9.6.10) | GS 95007-6-2:2017-04 (p. 9.6.9)","norm_bases":["MBN LV 112-2:2012-01 (p. 8.7.9)","MBN 50112-2:2023-05 (p. 12.7.9)","MBN 50216-1:2023-07 (p. 12.7.9)","MBN LV 212-1:2017-08 (p. 9.6.9)","MBN 50212-1:2023-04 (p. 12.7.9)","MBN LV 216-2:2017-07 (p. 9.6.9)","MBN 50112-4:2024-06 (p. 12.6.10)","GS 95007-1-1:2013-05 (p. 9.6.10)","GS 95007-1-2:2013-05 (p. 9.6.10)","GS 95007-3-1:2015-08 (p. 9.6.9)","GS 95007-3-2:2015-09 (p. 9.6.9)","GS 95007-6-1:2016-03 (p. 9.6.10)","GS 95007-6-2:2017-04 (p. 9.6.9)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Uderzenie kabla w niskiej temperaturze / Cold impact\nZakres:\nKomora klimatyczna -40 °C do 175 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nClimatic chamber -40 °C to 175 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. MBN LV 112-2:2012-01 (p. 8.7.9) | MBN 50112-2:2023-05 (p. 12.7.9) | MBN 50216-1:2023-07 (p. 12.7.9) | MBN LV 212-1:2017-08 (p. 9.6.9) | MBN 50212-1:2023-04 (p. 12.7.9) | MBN LV 216-2:2017-07 (p. 9.6.9) | MBN 50112-4:2024-06 (p. 12.6.10) | GS 95007-1-1:2013-05 (p. 9.6.10) | GS 95007-1-2:2013-05 (p. 9.6.10) | GS 95007-3-1:2015-08 (p. 9.6.9) | GS 95007-3-2:2015-09 (p. 9.6.9) | GS 95007-6-1:2016-03 (p. 9.6.10) | GS 95007-6-2:2017-04 (p. 9.6.9) Kable / Cables Uderzenie kabla w niskiej temperaturze / Cold impact\nZakres:\nKomora klimatyczna -40 °C do 175 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nClimatic chamber -40 °C to 175 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. MBN LV 112-2:2012-01 (p. 8.7.9) | MBN 50112-2:2023-05 (p. 12.7.9) | MBN 50216-1:2023-07 (p. 12.7.9) | MBN LV 212-1:2017-08 (p. 9.6.9) | MBN 50212-1:2023-04 (p. 12.7.9) | MBN LV 216-2:2017-07 (p. 9.6.9) | MBN 50112-4:2024-06 (p. 12.6.10) | GS 95007-1-1:2013-05 (p. 9.6.10) | GS 95007-1-2:2013-05 (p. 9.6.10) | GS 95007-3-1:2015-08 (p. 9.6.9) | GS 95007-3-2:2015-09 (p. 9.6.9) | GS 95007-6-1:2016-03 (p. 9.6.10) | GS 95007-6-2:2017-04 (p. 9.6.9)","categories":["other"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d974","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Cykliczne zmiany temperatury i wilgotności / Temperature and humidity cycling","parameters":[{"name":"Komora klimatyczna","range":"-40°C do 175°C, (90 ±10) % RH"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Zakres","range":"0,5 kV do 6 kV D.C."},{"name":"Climatic chamber","range":"-40 °C to 175 °C, (90 ± 10) %RH"},{"name":"Range","range":"0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Range","range":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"computed":[],"activity":"Cykliczne zmiany temperatury i wilgotności / Temperature and humidity cycling\nZakres:\nKomora klimatyczna -40°C do 175°C, (90 ±10) % RH\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nClimatic chamber -40 °C to 175 °C, (90 ± 10) %RH\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C.","reference":"ISO 19642-2:2019-01 (p. 5.4.9; 6.4.9) | ISO 19642-2:2023 (p. 5.5.9; 6.5.9) | ISO 19642-3:2019-01 (p. 5.5.9) | ISO 19642-4:2019-01 (p. 5.5.9) | ISO 19642-5:2019-01 (p. 5.5.9) | ISO 19642-6:2019-01 (p. 5.5.9) | ISO 19642-7:2019-01 (p. 6.5.9) | ISO 19642-8:2019-01 (p. 6.5.9) | ISO 19642-9:2019-01 (p. 6.5.9) | ISO 19642-10:2019-01 (p. 6.5.9) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.21) | ISO 6722-2:2013-12-01 (p. 5.21) | ISO 14572:2011-10 (p. 5.20)","norm_bases":["ISO 19642-2:2019-01 (p. 5.4.9; 6.4.9)","ISO 19642-2:2023 (p. 5.5.9; 6.5.9)","ISO 19642-3:2019-01 (p. 5.5.9)","ISO 19642-4:2019-01 (p. 5.5.9)","ISO 19642-5:2019-01 (p. 5.5.9)","ISO 19642-6:2019-01 (p. 5.5.9)","ISO 19642-7:2019-01 (p. 6.5.9)","ISO 19642-8:2019-01 (p. 6.5.9)","ISO 19642-9:2019-01 (p. 6.5.9)","ISO 19642-10:2019-01 (p. 6.5.9)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.21)","ISO 6722-2:2013-12-01 (p. 5.21)","ISO 14572:2011-10 (p. 5.20)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Cykliczne zmiany temperatury i wilgotności / Temperature and humidity cycling\nZakres:\nKomora klimatyczna -40°C do 175°C, (90 ±10) % RH\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nClimatic chamber -40 °C to 175 °C, (90 ± 10) %RH\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. ISO 19642-2:2019-01 (p. 5.4.9; 6.4.9) | ISO 19642-2:2023 (p. 5.5.9; 6.5.9) | ISO 19642-3:2019-01 (p. 5.5.9) | ISO 19642-4:2019-01 (p. 5.5.9) | ISO 19642-5:2019-01 (p. 5.5.9) | ISO 19642-6:2019-01 (p. 5.5.9) | ISO 19642-7:2019-01 (p. 6.5.9) | ISO 19642-8:2019-01 (p. 6.5.9) | ISO 19642-9:2019-01 (p. 6.5.9) | ISO 19642-10:2019-01 (p. 6.5.9) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.21) | ISO 6722-2:2013-12-01 (p. 5.21) | ISO 14572:2011-10 (p. 5.20) Kable / Cables Cykliczne zmiany temperatury i wilgotnosci / Temperature and humidity cycling\nZakres:\nKomora klimatyczna -40°C do 175°C, (90 ±10) % RH\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nClimatic chamber -40 °C to 175 °C, (90 ± 10) %RH\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. ISO 19642-2:2019-01 (p. 5.4.9; 6.4.9) | ISO 19642-2:2023 (p. 5.5.9; 6.5.9) | ISO 19642-3:2019-01 (p. 5.5.9) | ISO 19642-4:2019-01 (p. 5.5.9) | ISO 19642-5:2019-01 (p. 5.5.9) | ISO 19642-6:2019-01 (p. 5.5.9) | ISO 19642-7:2019-01 (p. 6.5.9) | ISO 19642-8:2019-01 (p. 6.5.9) | ISO 19642-9:2019-01 (p. 6.5.9) | ISO 19642-10:2019-01 (p. 6.5.9) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.21) | ISO 6722-2:2013-12-01 (p. 5.21) | ISO 14572:2011-10 (p. 5.20)","categories":["other"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d975","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"- Odporność na gorącą wodę - Właściwości elektryczne podczas starzenia w wodzie / - Resistance to hot water - Electrical properties with aging in water","parameters":[{"name":"Napięcie","range":"1 V do 1000 V D.C."},{"name":"Rezystancja","range":"2 kΩ - 1000 GΩ"},{"name":"Łaźnia","range":"temperatura do 90°C"},{"name":"Voltage","range":"1 V to 1000 V D.C."},{"name":"Resistance","range":"2 kΩ to 1000 GΩ"},{"name":"Temperature","range":"up to 90 °C"}],"technique":null,"techniques":[],"computed":[],"activity":"- Odporność na gorącą wodę - Właściwości elektryczne podczas starzenia w wodzie / - Resistance to hot water - Electrical properties with aging in water\nZakres:\nNapięcie 1 V do 1000 V D.C.\nRezystancja 2 kΩ - 1000 GΩ\nŁaźnia temperatura do 90°C\nVoltage 1 V to 1000 V D.C.\nResistance 2 kΩ to 1000 GΩ\nTemperature up to 90 °C","reference":"ISO 19642-2:2019-01 (p. 5.4.10) | ISO 19642-2:2023 (p. 5.5.10) | ISO 19642-3:2019-01 (p. 5.5.10) | ISO 19642-4:2019-01 (p. 5.5.10) | ISO 19642-5:2019-01 (p. 5.5.10) | ISO 19642-6:2019-01 (p. 5.5.10) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.20) | ISO 6722-2:2013-12-01 (p. 5.20) | LV 112-1:2013-04 (p. 9.6.14) | LV 112-1:2014-04 (p. 9.6.14) | LV 112-2:2007-11 (p. 8.7.13) | LV 112-2:2013-04 (p. 9.6.14) | LV 122:2015-05 (p. 11.6) | LV 122:2016-02 (p. 11.6) | LV 212-1:2015-01 (p. 9.6.12) | LV 212-2:2015-01 (p. 9.6.12) | LV 216-1:2015-07 (p. 9.6.14) | VW 60306-1:2018-09-01 (p. 9.6.14) | VW 60306-1:2021-10 (p. 9.7.14) | VW 60306-2:2013-04 (p. 9.6.14) | VW 60306-2:2021-11 (p. 9.7.14) | VW 60306-4:2021-12 (p. 9.7.14) | VW 75205:2019-11 (p. 11.6) | VW 75205:2023-05 (p. 11.6) | VW 75205:2024-04 (p. 11.7) | VW 75209-1:2015-01 (p. 9.6.12) | VW 75209-2:2015-01 (p. 9.6.12) | VW 75209-2:2021-12 (p. 9.7.11) | VW 75210-1:2023-06 (p. 9.7.14) | VW 75210-1:2024-08 (p. 9.7.14) | MBN LV 112-1:2016-03 (p. 9.6.14) | MBN 50112-1:2023-06 (p. 12.6.14) | MBN LV 112-2:2012-01 (p. 8.7.13) | MBN 50112-2:2023-05 (p. 12.7.13) | MBN 50216-1:2023-07 (p. 12.7.13) | MBN LV 122:2017-06 (p. 11.6) | MBN 50122:2023-07 (p. 13.6) | MBN LV 212-1:2017-08 (p. 9.6.12) | MBN 50112-4:2024-06 (p. 12.6.14) | GS 95007-1-1:2013-05 (p. 9.6.14) | GS 95007-1-2:2013-05 (p. 9.6.14) | GS 95007-1-5:2015-07 (p. 11.6) | GS 95007-3-1:2015-08 (p. 9.6.12) | GS 95007-3-2:2015-09 (p. 9.6.12) | GS 95007-6-1:2016-03 (p. 9.6.14)","norm_bases":["ISO 19642-2:2019-01 (p. 5.4.10)","ISO 19642-2:2023 (p. 5.5.10)","ISO 19642-3:2019-01 (p. 5.5.10)","ISO 19642-4:2019-01 (p. 5.5.10)","ISO 19642-5:2019-01 (p. 5.5.10)","ISO 19642-6:2019-01 (p. 5.5.10)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.20)","ISO 6722-2:2013-12-01 (p. 5.20)","LV 112-1:2013-04 (p. 9.6.14)","LV 112-1:2014-04 (p. 9.6.14)","LV 112-2:2007-11 (p. 8.7.13)","LV 112-2:2013-04 (p. 9.6.14)","LV 122:2015-05 (p. 11.6)","LV 122:2016-02 (p. 11.6)","LV 212-1:2015-01 (p. 9.6.12)","LV 212-2:2015-01 (p. 9.6.12)","LV 216-1:2015-07 (p. 9.6.14)","VW 60306-1:2018-09-01 (p. 9.6.14)","VW 60306-1:2021-10 (p. 9.7.14)","VW 60306-2:2013-04 (p. 9.6.14)","VW 60306-2:2021-11 (p. 9.7.14)","VW 60306-4:2021-12 (p. 9.7.14)","VW 75205:2019-11 (p. 11.6)","VW 75205:2023-05 (p. 11.6)","VW 75205:2024-04 (p. 11.7)","VW 75209-1:2015-01 (p. 9.6.12)","VW 75209-2:2015-01 (p. 9.6.12)","VW 75209-2:2021-12 (p. 9.7.11)","VW 75210-1:2023-06 (p. 9.7.14)","VW 75210-1:2024-08 (p. 9.7.14)","MBN LV 112-1:2016-03 (p. 9.6.14)","MBN 50112-1:2023-06 (p. 12.6.14)","MBN LV 112-2:2012-01 (p. 8.7.13)","MBN 50112-2:2023-05 (p. 12.7.13)","MBN 50216-1:2023-07 (p. 12.7.13)","MBN LV 122:2017-06 (p. 11.6)","MBN 50122:2023-07 (p. 13.6)","MBN LV 212-1:2017-08 (p. 9.6.12)","MBN 50112-4:2024-06 (p. 12.6.14)","GS 95007-1-1:2013-05 (p. 9.6.14)","GS 95007-1-2:2013-05 (p. 9.6.14)","GS 95007-1-5:2015-07 (p. 11.6)","GS 95007-3-1:2015-08 (p. 9.6.12)","GS 95007-3-2:2015-09 (p. 9.6.12)","GS 95007-6-1:2016-03 (p. 9.6.14)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables - Odporność na gorącą wodę - Właściwości elektryczne podczas starzenia w wodzie / - Resistance to hot water - Electrical properties with aging in water\nZakres:\nNapięcie 1 V do 1000 V D.C.\nRezystancja 2 kΩ - 1000 GΩ\nŁaźnia temperatura do 90°C\nVoltage 1 V to 1000 V D.C.\nResistance 2 kΩ to 1000 GΩ\nTemperature up to 90 °C ISO 19642-2:2019-01 (p. 5.4.10) | ISO 19642-2:2023 (p. 5.5.10) | ISO 19642-3:2019-01 (p. 5.5.10) | ISO 19642-4:2019-01 (p. 5.5.10) | ISO 19642-5:2019-01 (p. 5.5.10) | ISO 19642-6:2019-01 (p. 5.5.10) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.20) | ISO 6722-2:2013-12-01 (p. 5.20) | LV 112-1:2013-04 (p. 9.6.14) | LV 112-1:2014-04 (p. 9.6.14) | LV 112-2:2007-11 (p. 8.7.13) | LV 112-2:2013-04 (p. 9.6.14) | LV 122:2015-05 (p. 11.6) | LV 122:2016-02 (p. 11.6) | LV 212-1:2015-01 (p. 9.6.12) | LV 212-2:2015-01 (p. 9.6.12) | LV 216-1:2015-07 (p. 9.6.14) | VW 60306-1:2018-09-01 (p. 9.6.14) | VW 60306-1:2021-10 (p. 9.7.14) | VW 60306-2:2013-04 (p. 9.6.14) | VW 60306-2:2021-11 (p. 9.7.14) | VW 60306-4:2021-12 (p. 9.7.14) | VW 75205:2019-11 (p. 11.6) | VW 75205:2023-05 (p. 11.6) | VW 75205:2024-04 (p. 11.7) | VW 75209-1:2015-01 (p. 9.6.12) | VW 75209-2:2015-01 (p. 9.6.12) | VW 75209-2:2021-12 (p. 9.7.11) | VW 75210-1:2023-06 (p. 9.7.14) | VW 75210-1:2024-08 (p. 9.7.14) | MBN LV 112-1:2016-03 (p. 9.6.14) | MBN 50112-1:2023-06 (p. 12.6.14) | MBN LV 112-2:2012-01 (p. 8.7.13) | MBN 50112-2:2023-05 (p. 12.7.13) | MBN 50216-1:2023-07 (p. 12.7.13) | MBN LV 122:2017-06 (p. 11.6) | MBN 50122:2023-07 (p. 13.6) | MBN LV 212-1:2017-08 (p. 9.6.12) | MBN 50112-4:2024-06 (p. 12.6.14) | GS 95007-1-1:2013-05 (p. 9.6.14) | GS 95007-1-2:2013-05 (p. 9.6.14) | GS 95007-1-5:2015-07 (p. 11.6) | GS 95007-3-1:2015-08 (p. 9.6.12) | GS 95007-3-2:2015-09 (p. 9.6.12) | GS 95007-6-1:2016-03 (p. 9.6.14) Kable / Cables - Odpornosc na goraca wode - Wlasciwosci elektryczne podczas starzenia w wodzie / - Resistance to hot water - Electrical properties with aging in water\nZakres:\nNapiecie 1 V do 1000 V D.C.\nRezystancja 2 kΩ - 1000 GΩ\nLaznia temperatura do 90°C\nVoltage 1 V to 1000 V D.C.\nResistance 2 kΩ to 1000 GΩ\nTemperature up to 90 °C ISO 19642-2:2019-01 (p. 5.4.10) | ISO 19642-2:2023 (p. 5.5.10) | ISO 19642-3:2019-01 (p. 5.5.10) | ISO 19642-4:2019-01 (p. 5.5.10) | ISO 19642-5:2019-01 (p. 5.5.10) | ISO 19642-6:2019-01 (p. 5.5.10) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.20) | ISO 6722-2:2013-12-01 (p. 5.20) | LV 112-1:2013-04 (p. 9.6.14) | LV 112-1:2014-04 (p. 9.6.14) | LV 112-2:2007-11 (p. 8.7.13) | LV 112-2:2013-04 (p. 9.6.14) | LV 122:2015-05 (p. 11.6) | LV 122:2016-02 (p. 11.6) | LV 212-1:2015-01 (p. 9.6.12) | LV 212-2:2015-01 (p. 9.6.12) | LV 216-1:2015-07 (p. 9.6.14) | VW 60306-1:2018-09-01 (p. 9.6.14) | VW 60306-1:2021-10 (p. 9.7.14) | VW 60306-2:2013-04 (p. 9.6.14) | VW 60306-2:2021-11 (p. 9.7.14) | VW 60306-4:2021-12 (p. 9.7.14) | VW 75205:2019-11 (p. 11.6) | VW 75205:2023-05 (p. 11.6) | VW 75205:2024-04 (p. 11.7) | VW 75209-1:2015-01 (p. 9.6.12) | VW 75209-2:2015-01 (p. 9.6.12) | VW 75209-2:2021-12 (p. 9.7.11) | VW 75210-1:2023-06 (p. 9.7.14) | VW 75210-1:2024-08 (p. 9.7.14) | MBN LV 112-1:2016-03 (p. 9.6.14) | MBN 50112-1:2023-06 (p. 12.6.14) | MBN LV 112-2:2012-01 (p. 8.7.13) | MBN 50112-2:2023-05 (p. 12.7.13) | MBN 50216-1:2023-07 (p. 12.7.13) | MBN LV 122:2017-06 (p. 11.6) | MBN 50122:2023-07 (p. 13.6) | MBN LV 212-1:2017-08 (p. 9.6.12) | MBN 50112-4:2024-06 (p. 12.6.14) | GS 95007-1-1:2013-05 (p. 9.6.14) | GS 95007-1-2:2013-05 (p. 9.6.14) | GS 95007-1-5:2015-07 (p. 11.6) | GS 95007-3-1:2015-08 (p. 9.6.12) | GS 95007-3-2:2015-09 (p. 9.6.12) | GS 95007-6-1:2016-03 (p. 9.6.14)","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d976","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Odporność na chemikalia i kwas akumulatorowy / Resistance to chemicals and battery acid","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na chemikalia i kwas akumulatorowy / Resistance to chemicals and battery acid","reference":"ISO 19642-2:2019-01 (p. 5.4.11; 6.4.10) | ISO 19642-2:2023 (p. 5.5.11; 6.5.10) | ISO 19642-3:2019-01 (p. 5.5.11) | ISO 19642-4:2019-01 (p. 5.5.11) | ISO 19642-5:2019-01 (p. 5.5.11) | ISO 19642-6:2019-01 (p. 5.5.11) | ISO 19642-7:2019-01 (p. 6.5.10) | ISO 19642-8:2019-01 (p. 6.5.10) | ISO 19642-9:2019-01 (p. 6.5.10) | ISO 19642-10:2019-01 (p. 6.5.10) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.17.3; 5.17.4; 5.17.5) | ISO 6722-2:2013-12-01 (p. 5.17) | ISO 14572:2011-10 (p. 5.17) | LV 112-1:2013-04 (p. 9.8.1) | LV 112-1:2014-04 (p. 9.8.1) | LV 112-2:2007-11 (p. 8.9.1) | LV 112-2:2013-04 (p. 9.8.1) | LV 212-1:2015-01 (p. 9.8.1) | LV 212-2:2015-01 (p. 9.8.1) | LV 216-1:2015-07 (p. 9.8.1) | LV 216-2:2017-02 (p. 9.8.1) | VW 60306-1:2018-09-01 (p. 9.8.1) | VW 60306-1:2021-10 (p. 9.9) | VW 60306-2:2013-04 (p. 9.8.1) | VW 60306-2:2021-11 (p. 9.9) | VW 60306-4:2021-12 (p. 9.9) | VW 75209-1:2015-01 (p. 9.8.1) | VW 75209-1:2021-12 (p. 9.9) | VW 75209-2:2015-01 (p. 9.8.1) | VW 75209-2:2021-12 (p. 9.9) | MBN LV 112-1:2016-03 (p. 9.8.1) | MBN 50112-1:2023-06 (p. 12.8.2) | MBN LV 112-2:2012-01 (p. 8.9.1) | MBN 50112-2: 2023-05 (p. 12.9.1) | MBN 50216-1:2023-07 (p. 12.9.1) | MBN LV 212-1:2017-08 (p. 9.8.1) | MBN 50212-1:2023-04 (p. 12.9.2) | MBN LV 216-2:2017-07 (p. 9.8.1) | MBN 50112-4:2024-06 (p. 12.8.2) | GS 95007-1-1:2013-05 (p. 9.8.1) | GS 95007-1-2:2013-05 (p. 9.8.1) | GS 95007-3-1:2015-08 (p. 9.8.1) | GS 95007-3-2:2015-09 (p. 9.8.1) | GS 95007-6-1:2016-03 (p. 9.8.1) | GS 95007-6-2:2017-04 (p. 9.8.1)","norm_bases":["ISO 19642-2:2019-01 (p. 5.4.11; 6.4.10)","ISO 19642-2:2023 (p. 5.5.11; 6.5.10)","ISO 19642-3:2019-01 (p. 5.5.11)","ISO 19642-4:2019-01 (p. 5.5.11)","ISO 19642-5:2019-01 (p. 5.5.11)","ISO 19642-6:2019-01 (p. 5.5.11)","ISO 19642-7:2019-01 (p. 6.5.10)","ISO 19642-8:2019-01 (p. 6.5.10)","ISO 19642-9:2019-01 (p. 6.5.10)","ISO 19642-10:2019-01 (p. 6.5.10)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.17.3; 5.17.4; 5.17.5)","ISO 6722-2:2013-12-01 (p. 5.17)","ISO 14572:2011-10 (p. 5.17)","LV 112-1:2013-04 (p. 9.8.1)","LV 112-1:2014-04 (p. 9.8.1)","LV 112-2:2007-11 (p. 8.9.1)","LV 112-2:2013-04 (p. 9.8.1)","LV 212-1:2015-01 (p. 9.8.1)","LV 212-2:2015-01 (p. 9.8.1)","LV 216-1:2015-07 (p. 9.8.1)","LV 216-2:2017-02 (p. 9.8.1)","VW 60306-1:2018-09-01 (p. 9.8.1)","VW 60306-1:2021-10 (p. 9.9)","VW 60306-2:2013-04 (p. 9.8.1)","VW 60306-2:2021-11 (p. 9.9)","VW 60306-4:2021-12 (p. 9.9)","VW 75209-1:2015-01 (p. 9.8.1)","VW 75209-1:2021-12 (p. 9.9)","VW 75209-2:2015-01 (p. 9.8.1)","VW 75209-2:2021-12 (p. 9.9)","MBN LV 112-1:2016-03 (p. 9.8.1)","MBN 50112-1:2023-06 (p. 12.8.2)","MBN LV 112-2:2012-01 (p. 8.9.1)","MBN 50112-2: 2023-05 (p. 12.9.1)","MBN 50216-1:2023-07 (p. 12.9.1)","MBN LV 212-1:2017-08 (p. 9.8.1)","MBN 50212-1:2023-04 (p. 12.9.2)","MBN LV 216-2:2017-07 (p. 9.8.1)","MBN 50112-4:2024-06 (p. 12.8.2)","GS 95007-1-1:2013-05 (p. 9.8.1)","GS 95007-1-2:2013-05 (p. 9.8.1)","GS 95007-3-1:2015-08 (p. 9.8.1)","GS 95007-3-2:2015-09 (p. 9.8.1)","GS 95007-6-1:2016-03 (p. 9.8.1)","GS 95007-6-2:2017-04 (p. 9.8.1)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Odporność na chemikalia i kwas akumulatorowy / Resistance to chemicals and battery acid ISO 19642-2:2019-01 (p. 5.4.11; 6.4.10) | ISO 19642-2:2023 (p. 5.5.11; 6.5.10) | ISO 19642-3:2019-01 (p. 5.5.11) | ISO 19642-4:2019-01 (p. 5.5.11) | ISO 19642-5:2019-01 (p. 5.5.11) | ISO 19642-6:2019-01 (p. 5.5.11) | ISO 19642-7:2019-01 (p. 6.5.10) | ISO 19642-8:2019-01 (p. 6.5.10) | ISO 19642-9:2019-01 (p. 6.5.10) | ISO 19642-10:2019-01 (p. 6.5.10) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.17.3; 5.17.4; 5.17.5) | ISO 6722-2:2013-12-01 (p. 5.17) | ISO 14572:2011-10 (p. 5.17) | LV 112-1:2013-04 (p. 9.8.1) | LV 112-1:2014-04 (p. 9.8.1) | LV 112-2:2007-11 (p. 8.9.1) | LV 112-2:2013-04 (p. 9.8.1) | LV 212-1:2015-01 (p. 9.8.1) | LV 212-2:2015-01 (p. 9.8.1) | LV 216-1:2015-07 (p. 9.8.1) | LV 216-2:2017-02 (p. 9.8.1) | VW 60306-1:2018-09-01 (p. 9.8.1) | VW 60306-1:2021-10 (p. 9.9) | VW 60306-2:2013-04 (p. 9.8.1) | VW 60306-2:2021-11 (p. 9.9) | VW 60306-4:2021-12 (p. 9.9) | VW 75209-1:2015-01 (p. 9.8.1) | VW 75209-1:2021-12 (p. 9.9) | VW 75209-2:2015-01 (p. 9.8.1) | VW 75209-2:2021-12 (p. 9.9) | MBN LV 112-1:2016-03 (p. 9.8.1) | MBN 50112-1:2023-06 (p. 12.8.2) | MBN LV 112-2:2012-01 (p. 8.9.1) | MBN 50112-2: 2023-05 (p. 12.9.1) | MBN 50216-1:2023-07 (p. 12.9.1) | MBN LV 212-1:2017-08 (p. 9.8.1) | MBN 50212-1:2023-04 (p. 12.9.2) | MBN LV 216-2:2017-07 (p. 9.8.1) | MBN 50112-4:2024-06 (p. 12.8.2) | GS 95007-1-1:2013-05 (p. 9.8.1) | GS 95007-1-2:2013-05 (p. 9.8.1) | GS 95007-3-1:2015-08 (p. 9.8.1) | GS 95007-3-2:2015-09 (p. 9.8.1) | GS 95007-6-1:2016-03 (p. 9.8.1) | GS 95007-6-2:2017-04 (p. 9.8.1) Kable / Cables Odpornosc na chemikalia i kwas akumulatorowy / Resistance to chemicals and battery acid ISO 19642-2:2019-01 (p. 5.4.11; 6.4.10) | ISO 19642-2:2023 (p. 5.5.11; 6.5.10) | ISO 19642-3:2019-01 (p. 5.5.11) | ISO 19642-4:2019-01 (p. 5.5.11) | ISO 19642-5:2019-01 (p. 5.5.11) | ISO 19642-6:2019-01 (p. 5.5.11) | ISO 19642-7:2019-01 (p. 6.5.10) | ISO 19642-8:2019-01 (p. 6.5.10) | ISO 19642-9:2019-01 (p. 6.5.10) | ISO 19642-10:2019-01 (p. 6.5.10) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.17.3; 5.17.4; 5.17.5) | ISO 6722-2:2013-12-01 (p. 5.17) | ISO 14572:2011-10 (p. 5.17) | LV 112-1:2013-04 (p. 9.8.1) | LV 112-1:2014-04 (p. 9.8.1) | LV 112-2:2007-11 (p. 8.9.1) | LV 112-2:2013-04 (p. 9.8.1) | LV 212-1:2015-01 (p. 9.8.1) | LV 212-2:2015-01 (p. 9.8.1) | LV 216-1:2015-07 (p. 9.8.1) | LV 216-2:2017-02 (p. 9.8.1) | VW 60306-1:2018-09-01 (p. 9.8.1) | VW 60306-1:2021-10 (p. 9.9) | VW 60306-2:2013-04 (p. 9.8.1) | VW 60306-2:2021-11 (p. 9.9) | VW 60306-4:2021-12 (p. 9.9) | VW 75209-1:2015-01 (p. 9.8.1) | VW 75209-1:2021-12 (p. 9.9) | VW 75209-2:2015-01 (p. 9.8.1) | VW 75209-2:2021-12 (p. 9.9) | MBN LV 112-1:2016-03 (p. 9.8.1) | MBN 50112-1:2023-06 (p. 12.8.2) | MBN LV 112-2:2012-01 (p. 8.9.1) | MBN 50112-2: 2023-05 (p. 12.9.1) | MBN 50216-1:2023-07 (p. 12.9.1) | MBN LV 212-1:2017-08 (p. 9.8.1) | MBN 50212-1:2023-04 (p. 12.9.2) | MBN LV 216-2:2017-07 (p. 9.8.1) | MBN 50112-4:2024-06 (p. 12.8.2) | GS 95007-1-1:2013-05 (p. 9.8.1) | GS 95007-1-2:2013-05 (p. 9.8.1) | GS 95007-3-1:2015-08 (p. 9.8.1) | GS 95007-3-2:2015-09 (p. 9.8.1) | GS 95007-6-1:2016-03 (p. 9.8.1) | GS 95007-6-2:2017-04 (p. 9.8.1)","categories":["other"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d977","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Odporności na pękanie zmęczeniowe / Stress cracking resistance","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporności na pękanie zmęczeniowe / Stress cracking resistance","reference":"ISO 19642-2:2019-01 (p. 5.4.13) | ISO 19642-2:2023 (p. 5.5.13) | ISO 19642-3:2019-01 (p. 5.5.13) | ISO 19642-4:2019-01 (p. 5.5.13) | ISO 19642-5:2019-01 (p. 5.5.13) | ISO 19642-6:2019-01 (p. 5.5.13) | LV 112-1:2013-04 (p. 9.6.1) | LV 112-1:2014-04 (p. 9.6.1) | LV 112-2:2007-11 (p. 8.7.1) | LV 112-2:2013-04 (p. 9.6.1) | LV 212-2:2015-01 (p. 9.6.1) | LV 216-1:2015-07 (p. 9.6.1) | LV 216-2:2017-02 (p. 9.6.1) | VW 60306-1:2018-09-01 (p. 9.6.1) | VW 60306-1:2021-10 (p. 9.7.1) | VW 60306-2:2013-04 (p. 9.6.1) | VW 60306-2:2021-11 (p. 9.7.1) | VW 60306-4:2021-12 (p. 9.7.1) | VW 75209-2:2015-01 (p. 9.6.1) | VW 75210-1:2023-06 (p. 9.7.1) | VW 75210-1:2024-08 (p. 9.7.1) | VW 75210-2:2023-06 (p. 9.7.1) | MBN LV 112-1:2016-03 (p. 9.6.1) | MBN 50112-1:2023-06 (p. 12.6.1) | MBN LV 112-2:2012-01 (p. 8.7.1) | MBN 50112-2: 2023-05 (p. 12.7.1) | MBN 50216-1:2023-07 (p. 12.7.1) | MBN LV 216-2:2017-07 (p. 9.6.1) | MBN 50112-4:2024-06 (p. 12.6.1) | GS 95007-1-1:2013-05 (p. 9.6.1) | GS 95007-1-2:2013-05 (p. 9.6.1) | GS 95007-3-2:2015-09 (p. 9.6.1) | GS 95007-6-1:2016-03 (p. 9.6.1) | GS 95007-6-2:2017-04 (p. 9.6.1)","norm_bases":["ISO 19642-2:2019-01 (p. 5.4.13)","ISO 19642-2:2023 (p. 5.5.13)","ISO 19642-3:2019-01 (p. 5.5.13)","ISO 19642-4:2019-01 (p. 5.5.13)","ISO 19642-5:2019-01 (p. 5.5.13)","ISO 19642-6:2019-01 (p. 5.5.13)","LV 112-1:2013-04 (p. 9.6.1)","LV 112-1:2014-04 (p. 9.6.1)","LV 112-2:2007-11 (p. 8.7.1)","LV 112-2:2013-04 (p. 9.6.1)","LV 212-2:2015-01 (p. 9.6.1)","LV 216-1:2015-07 (p. 9.6.1)","LV 216-2:2017-02 (p. 9.6.1)","VW 60306-1:2018-09-01 (p. 9.6.1)","VW 60306-1:2021-10 (p. 9.7.1)","VW 60306-2:2013-04 (p. 9.6.1)","VW 60306-2:2021-11 (p. 9.7.1)","VW 60306-4:2021-12 (p. 9.7.1)","VW 75209-2:2015-01 (p. 9.6.1)","VW 75210-1:2023-06 (p. 9.7.1)","VW 75210-1:2024-08 (p. 9.7.1)","VW 75210-2:2023-06 (p. 9.7.1)","MBN LV 112-1:2016-03 (p. 9.6.1)","MBN 50112-1:2023-06 (p. 12.6.1)","MBN LV 112-2:2012-01 (p. 8.7.1)","MBN 50112-2: 2023-05 (p. 12.7.1)","MBN 50216-1:2023-07 (p. 12.7.1)","MBN LV 216-2:2017-07 (p. 9.6.1)","MBN 50112-4:2024-06 (p. 12.6.1)","GS 95007-1-1:2013-05 (p. 9.6.1)","GS 95007-1-2:2013-05 (p. 9.6.1)","GS 95007-3-2:2015-09 (p. 9.6.1)","GS 95007-6-1:2016-03 (p. 9.6.1)","GS 95007-6-2:2017-04 (p. 9.6.1)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Odporności na pękanie zmęczeniowe / Stress cracking resistance ISO 19642-2:2019-01 (p. 5.4.13) | ISO 19642-2:2023 (p. 5.5.13) | ISO 19642-3:2019-01 (p. 5.5.13) | ISO 19642-4:2019-01 (p. 5.5.13) | ISO 19642-5:2019-01 (p. 5.5.13) | ISO 19642-6:2019-01 (p. 5.5.13) | LV 112-1:2013-04 (p. 9.6.1) | LV 112-1:2014-04 (p. 9.6.1) | LV 112-2:2007-11 (p. 8.7.1) | LV 112-2:2013-04 (p. 9.6.1) | LV 212-2:2015-01 (p. 9.6.1) | LV 216-1:2015-07 (p. 9.6.1) | LV 216-2:2017-02 (p. 9.6.1) | VW 60306-1:2018-09-01 (p. 9.6.1) | VW 60306-1:2021-10 (p. 9.7.1) | VW 60306-2:2013-04 (p. 9.6.1) | VW 60306-2:2021-11 (p. 9.7.1) | VW 60306-4:2021-12 (p. 9.7.1) | VW 75209-2:2015-01 (p. 9.6.1) | VW 75210-1:2023-06 (p. 9.7.1) | VW 75210-1:2024-08 (p. 9.7.1) | VW 75210-2:2023-06 (p. 9.7.1) | MBN LV 112-1:2016-03 (p. 9.6.1) | MBN 50112-1:2023-06 (p. 12.6.1) | MBN LV 112-2:2012-01 (p. 8.7.1) | MBN 50112-2: 2023-05 (p. 12.7.1) | MBN 50216-1:2023-07 (p. 12.7.1) | MBN LV 216-2:2017-07 (p. 9.6.1) | MBN 50112-4:2024-06 (p. 12.6.1) | GS 95007-1-1:2013-05 (p. 9.6.1) | GS 95007-1-2:2013-05 (p. 9.6.1) | GS 95007-3-2:2015-09 (p. 9.6.1) | GS 95007-6-1:2016-03 (p. 9.6.1) | GS 95007-6-2:2017-04 (p. 9.6.1) Kable / Cables Odpornosci na pekanie zmeczeniowe / Stress cracking resistance ISO 19642-2:2019-01 (p. 5.4.13) | ISO 19642-2:2023 (p. 5.5.13) | ISO 19642-3:2019-01 (p. 5.5.13) | ISO 19642-4:2019-01 (p. 5.5.13) | ISO 19642-5:2019-01 (p. 5.5.13) | ISO 19642-6:2019-01 (p. 5.5.13) | LV 112-1:2013-04 (p. 9.6.1) | LV 112-1:2014-04 (p. 9.6.1) | LV 112-2:2007-11 (p. 8.7.1) | LV 112-2:2013-04 (p. 9.6.1) | LV 212-2:2015-01 (p. 9.6.1) | LV 216-1:2015-07 (p. 9.6.1) | LV 216-2:2017-02 (p. 9.6.1) | VW 60306-1:2018-09-01 (p. 9.6.1) | VW 60306-1:2021-10 (p. 9.7.1) | VW 60306-2:2013-04 (p. 9.6.1) | VW 60306-2:2021-11 (p. 9.7.1) | VW 60306-4:2021-12 (p. 9.7.1) | VW 75209-2:2015-01 (p. 9.6.1) | VW 75210-1:2023-06 (p. 9.7.1) | VW 75210-1:2024-08 (p. 9.7.1) | VW 75210-2:2023-06 (p. 9.7.1) | MBN LV 112-1:2016-03 (p. 9.6.1) | MBN 50112-1:2023-06 (p. 12.6.1) | MBN LV 112-2:2012-01 (p. 8.7.1) | MBN 50112-2: 2023-05 (p. 12.7.1) | MBN 50216-1:2023-07 (p. 12.7.1) | MBN LV 216-2:2017-07 (p. 9.6.1) | MBN 50112-4:2024-06 (p. 12.6.1) | GS 95007-1-1:2013-05 (p. 9.6.1) | GS 95007-1-2:2013-05 (p. 9.6.1) | GS 95007-3-2:2015-09 (p. 9.6.1) | GS 95007-6-1:2016-03 (p. 9.6.1) | GS 95007-6-2:2017-04 (p. 9.6.1)","categories":["other"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d978","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Odporność kabla na rozprzestrzenianie ognia / Resistance to flame propagation","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność kabla na rozprzestrzenianie ognia / Resistance to flame propagation","reference":"ISO 19642-2:2019-01 (p. 5.4.15; 6.4.14) | ISO 19642-2:2023 (p. 5.5.14; 6.5.14) | ISO 19642-3:2019-01 (p. 5.5.15) | ISO 19642-4:2019-01 (p. 5.5.15) | ISO 19642-5:2019-01 (p. 5.5.15) | ISO 19642-6:2019-01 (p. 5.5.15) | ISO 19642-7:2019-01 (p. 6.5.14) | ISO 19642-8:2019-01 (p. 6.5.14) | ISO 19642-9:2019-01 (p. 6.5.14) | ISO 19642-10:2019-01 (p. 6.5.14) | ISO 6722-1:2011-10-15; corr.1:2012-09- 15 (p. 5.22) | ISO 6722-2:2013-12-01 (p. 5.22) | ISO 14572:2011-10 (p. 5.21) | LV 112-1:2013-04 (p. 9.4) | LV 112-1:2014-04 (p. 9.4) | LV 112-2:2007-11 (p. 8.5) | LV 112-2:2013-04 (p. 9.4) | LV 122:2015-05 (p. 11.3) | LV 122:2016-02 (p. 11.4) | LV 212-1:2015-01 (p. 9.4)","norm_bases":["ISO 19642-2:2019-01 (p. 5.4.15; 6.4.14)","ISO 19642-2:2023 (p. 5.5.14; 6.5.14)","ISO 19642-3:2019-01 (p. 5.5.15)","ISO 19642-4:2019-01 (p. 5.5.15)","ISO 19642-5:2019-01 (p. 5.5.15)","ISO 19642-6:2019-01 (p. 5.5.15)","ISO 19642-7:2019-01 (p. 6.5.14)","ISO 19642-8:2019-01 (p. 6.5.14)","ISO 19642-9:2019-01 (p. 6.5.14)","ISO 19642-10:2019-01 (p. 6.5.14)","ISO 6722-1:2011-10-15; corr.1:2012-09- 15 (p. 5.22)","ISO 6722-2:2013-12-01 (p. 5.22)","ISO 14572:2011-10 (p. 5.21)","LV 112-1:2013-04 (p. 9.4)","LV 112-1:2014-04 (p. 9.4)","LV 112-2:2007-11 (p. 8.5)","LV 112-2:2013-04 (p. 9.4)","LV 122:2015-05 (p. 11.3)","LV 122:2016-02 (p. 11.4)","LV 212-1:2015-01 (p. 9.4)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Odporność kabla na rozprzestrzenianie ognia / Resistance to flame propagation ISO 19642-2:2019-01 (p. 5.4.15; 6.4.14) | ISO 19642-2:2023 (p. 5.5.14; 6.5.14) | ISO 19642-3:2019-01 (p. 5.5.15) | ISO 19642-4:2019-01 (p. 5.5.15) | ISO 19642-5:2019-01 (p. 5.5.15) | ISO 19642-6:2019-01 (p. 5.5.15) | ISO 19642-7:2019-01 (p. 6.5.14) | ISO 19642-8:2019-01 (p. 6.5.14) | ISO 19642-9:2019-01 (p. 6.5.14) | ISO 19642-10:2019-01 (p. 6.5.14) | ISO 6722-1:2011-10-15; corr.1:2012-09- 15 (p. 5.22) | ISO 6722-2:2013-12-01 (p. 5.22) | ISO 14572:2011-10 (p. 5.21) | LV 112-1:2013-04 (p. 9.4) | LV 112-1:2014-04 (p. 9.4) | LV 112-2:2007-11 (p. 8.5) | LV 112-2:2013-04 (p. 9.4) | LV 122:2015-05 (p. 11.3) | LV 122:2016-02 (p. 11.4) | LV 212-1:2015-01 (p. 9.4) Kable / Cables Odpornosc kabla na rozprzestrzenianie ognia / Resistance to flame propagation ISO 19642-2:2019-01 (p. 5.4.15; 6.4.14) | ISO 19642-2:2023 (p. 5.5.14; 6.5.14) | ISO 19642-3:2019-01 (p. 5.5.15) | ISO 19642-4:2019-01 (p. 5.5.15) | ISO 19642-5:2019-01 (p. 5.5.15) | ISO 19642-6:2019-01 (p. 5.5.15) | ISO 19642-7:2019-01 (p. 6.5.14) | ISO 19642-8:2019-01 (p. 6.5.14) | ISO 19642-9:2019-01 (p. 6.5.14) | ISO 19642-10:2019-01 (p. 6.5.14) | ISO 6722-1:2011-10-15; corr.1:2012-09- 15 (p. 5.22) | ISO 6722-2:2013-12-01 (p. 5.22) | ISO 14572:2011-10 (p. 5.21) | LV 112-1:2013-04 (p. 9.4) | LV 112-1:2014-04 (p. 9.4) | LV 112-2:2007-11 (p. 8.5) | LV 112-2:2013-04 (p. 9.4) | LV 122:2015-05 (p. 11.3) | LV 122:2016-02 (p. 11.4) | LV 212-1:2015-01 (p. 9.4)","categories":["other"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d979","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Odporność kabla na rozprzestrzenianie ognia / Resistance to flame propagation","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność kabla na rozprzestrzenianie ognia / Resistance to flame propagation","reference":"LV 216-1:2015-07 (p. 9.4) | LV 212-2:2015-01 (p. 9.4) | LV 216-2:2017-02 (p. 9.4) | VW 60306-1:2018-09-01 (p. 9.4) | VW 60306-1:2021-10 (p. 9.5) | VW 60306-2:2013-04 (p. 9.4) | VW 60306-2:2021-11 (p. 9.5) | VW 60306-4:2021-12 (p. 9.5) | VW 75205:2019-11 (p. 11.3) | VW 75205:2023-05 (p. 11.3) | VW 75205:2024-04 (p. 11.4) | VW 75209-1:2015-01 (p. 9.4) | VW 75209-1:2021-12 (p. 9.5) | VW 75209-2:2015-01 (p. 9.4) | VW 75209-2:2021-12 (p. 9.4.4) | VW 75210-1:2023-06 (p. 9.5) | VW 75210-1:2024-08 (p. 9.5) | VW 75210-2:2023-06 (p. 9.5) | MBN LV 112-1:2016-03 (p. 9.4) | MBN 50112-1:2023-06 (p. 12.4) | MBN LV 112-2:2012-01 (p. 8.5) | MBN 50112-2:2023-05 (p. 12.5) | MBN 50216-1:2023-07 (p. 12.5) | MBN LV 122:2017-06 (p. 11.4) | MBN 50122:2023-07 (p. 13.4) | MBN LV 212-1:2017-08 (p. 9.4) | MBN 50212-1:2023-04 (p. 12.5) | MBN LV 216-2:2017-07 (p. 9.4) | MBN 50112-4:2024-06 (p. 12.4) | GS 95007-1-1:2013-05 (p. 9.4) | GS 95007-1-2:2013-05 (p. 9.4) | GS 95007-1-5:2015-07 (p. 11.3) | GS 95007-3-1:2015-08 (p. 9.4) | GS 95007-3-2:2015-09 (p. 9.4) | GS 95007-6-1:2016-03 (p. 9.4) | GS 95007-6-2:2017-04 (p. 9.4)","norm_bases":["LV 216-1:2015-07 (p. 9.4)","LV 212-2:2015-01 (p. 9.4)","LV 216-2:2017-02 (p. 9.4)","VW 60306-1:2018-09-01 (p. 9.4)","VW 60306-1:2021-10 (p. 9.5)","VW 60306-2:2013-04 (p. 9.4)","VW 60306-2:2021-11 (p. 9.5)","VW 60306-4:2021-12 (p. 9.5)","VW 75205:2019-11 (p. 11.3)","VW 75205:2023-05 (p. 11.3)","VW 75205:2024-04 (p. 11.4)","VW 75209-1:2015-01 (p. 9.4)","VW 75209-1:2021-12 (p. 9.5)","VW 75209-2:2015-01 (p. 9.4)","VW 75209-2:2021-12 (p. 9.4.4)","VW 75210-1:2023-06 (p. 9.5)","VW 75210-1:2024-08 (p. 9.5)","VW 75210-2:2023-06 (p. 9.5)","MBN LV 112-1:2016-03 (p. 9.4)","MBN 50112-1:2023-06 (p. 12.4)","MBN LV 112-2:2012-01 (p. 8.5)","MBN 50112-2:2023-05 (p. 12.5)","MBN 50216-1:2023-07 (p. 12.5)","MBN LV 122:2017-06 (p. 11.4)","MBN 50122:2023-07 (p. 13.4)","MBN LV 212-1:2017-08 (p. 9.4)","MBN 50212-1:2023-04 (p. 12.5)","MBN LV 216-2:2017-07 (p. 9.4)","MBN 50112-4:2024-06 (p. 12.4)","GS 95007-1-1:2013-05 (p. 9.4)","GS 95007-1-2:2013-05 (p. 9.4)","GS 95007-1-5:2015-07 (p. 11.3)","GS 95007-3-1:2015-08 (p. 9.4)","GS 95007-3-2:2015-09 (p. 9.4)","GS 95007-6-1:2016-03 (p. 9.4)","GS 95007-6-2:2017-04 (p. 9.4)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Odporność kabla na rozprzestrzenianie ognia / Resistance to flame propagation LV 216-1:2015-07 (p. 9.4) | LV 212-2:2015-01 (p. 9.4) | LV 216-2:2017-02 (p. 9.4) | VW 60306-1:2018-09-01 (p. 9.4) | VW 60306-1:2021-10 (p. 9.5) | VW 60306-2:2013-04 (p. 9.4) | VW 60306-2:2021-11 (p. 9.5) | VW 60306-4:2021-12 (p. 9.5) | VW 75205:2019-11 (p. 11.3) | VW 75205:2023-05 (p. 11.3) | VW 75205:2024-04 (p. 11.4) | VW 75209-1:2015-01 (p. 9.4) | VW 75209-1:2021-12 (p. 9.5) | VW 75209-2:2015-01 (p. 9.4) | VW 75209-2:2021-12 (p. 9.4.4) | VW 75210-1:2023-06 (p. 9.5) | VW 75210-1:2024-08 (p. 9.5) | VW 75210-2:2023-06 (p. 9.5) | MBN LV 112-1:2016-03 (p. 9.4) | MBN 50112-1:2023-06 (p. 12.4) | MBN LV 112-2:2012-01 (p. 8.5) | MBN 50112-2:2023-05 (p. 12.5) | MBN 50216-1:2023-07 (p. 12.5) | MBN LV 122:2017-06 (p. 11.4) | MBN 50122:2023-07 (p. 13.4) | MBN LV 212-1:2017-08 (p. 9.4) | MBN 50212-1:2023-04 (p. 12.5) | MBN LV 216-2:2017-07 (p. 9.4) | MBN 50112-4:2024-06 (p. 12.4) | GS 95007-1-1:2013-05 (p. 9.4) | GS 95007-1-2:2013-05 (p. 9.4) | GS 95007-1-5:2015-07 (p. 11.3) | GS 95007-3-1:2015-08 (p. 9.4) | GS 95007-3-2:2015-09 (p. 9.4) | GS 95007-6-1:2016-03 (p. 9.4) | GS 95007-6-2:2017-04 (p. 9.4) Kable / Cables Odpornosc kabla na rozprzestrzenianie ognia / Resistance to flame propagation LV 216-1:2015-07 (p. 9.4) | LV 212-2:2015-01 (p. 9.4) | LV 216-2:2017-02 (p. 9.4) | VW 60306-1:2018-09-01 (p. 9.4) | VW 60306-1:2021-10 (p. 9.5) | VW 60306-2:2013-04 (p. 9.4) | VW 60306-2:2021-11 (p. 9.5) | VW 60306-4:2021-12 (p. 9.5) | VW 75205:2019-11 (p. 11.3) | VW 75205:2023-05 (p. 11.3) | VW 75205:2024-04 (p. 11.4) | VW 75209-1:2015-01 (p. 9.4) | VW 75209-1:2021-12 (p. 9.5) | VW 75209-2:2015-01 (p. 9.4) | VW 75209-2:2021-12 (p. 9.4.4) | VW 75210-1:2023-06 (p. 9.5) | VW 75210-1:2024-08 (p. 9.5) | VW 75210-2:2023-06 (p. 9.5) | MBN LV 112-1:2016-03 (p. 9.4) | MBN 50112-1:2023-06 (p. 12.4) | MBN LV 112-2:2012-01 (p. 8.5) | MBN 50112-2:2023-05 (p. 12.5) | MBN 50216-1:2023-07 (p. 12.5) | MBN LV 122:2017-06 (p. 11.4) | MBN 50122:2023-07 (p. 13.4) | MBN LV 212-1:2017-08 (p. 9.4) | MBN 50212-1:2023-04 (p. 12.5) | MBN LV 216-2:2017-07 (p. 9.4) | MBN 50112-4:2024-06 (p. 12.4) | GS 95007-1-1:2013-05 (p. 9.4) | GS 95007-1-2:2013-05 (p. 9.4) | GS 95007-1-5:2015-07 (p. 11.3) | GS 95007-3-1:2015-08 (p. 9.4) | GS 95007-3-2:2015-09 (p. 9.4) | GS 95007-6-1:2016-03 (p. 9.4) | GS 95007-6-2:2017-04 (p. 9.4)","categories":["other"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d97a","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Ciągłość elektryczna / Electrical continuity","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ciągłość elektryczna / Electrical continuity","reference":"ISO 19642-2:2019-01 (p. 6.2.1) | ISO 19642-2:2023 (p. 6.3.1) | ISO 19642-7:2019-01 (p. 6.3.1) | ISO 19642-8:2019-01 (p. 6.3.1) | ISO 19642-9:2019-01 (p. 6.3.1) | ISO 19642-10:2019-01 (p. 6.3.1) | ISO 14572:2011-10 (p. 5.4)","norm_bases":["ISO 19642-2:2019-01 (p. 6.2.1)","ISO 19642-2:2023 (p. 6.3.1)","ISO 19642-7:2019-01 (p. 6.3.1)","ISO 19642-8:2019-01 (p. 6.3.1)","ISO 19642-9:2019-01 (p. 6.3.1)","ISO 19642-10:2019-01 (p. 6.3.1)","ISO 14572:2011-10 (p. 5.4)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Ciągłość elektryczna / Electrical continuity ISO 19642-2:2019-01 (p. 6.2.1) | ISO 19642-2:2023 (p. 6.3.1) | ISO 19642-7:2019-01 (p. 6.3.1) | ISO 19642-8:2019-01 (p. 6.3.1) | ISO 19642-9:2019-01 (p. 6.3.1) | ISO 19642-10:2019-01 (p. 6.3.1) | ISO 14572:2011-10 (p. 5.4) Kable / Cables Ciaglosc elektryczna / Electrical continuity ISO 19642-2:2019-01 (p. 6.2.1) | ISO 19642-2:2023 (p. 6.3.1) | ISO 19642-7:2019-01 (p. 6.3.1) | ISO 19642-8:2019-01 (p. 6.3.1) | ISO 19642-9:2019-01 (p. 6.3.1) | ISO 19642-10:2019-01 (p. 6.3.1) | ISO 14572:2011-10 (p. 5.4)","categories":["other"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d97b","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Owalność kabla / Ovality","parameters":[{"name":"Zakres","range":"Średnica zewnętrzna kabla ≤ 25 mm"},{"name":"Range","range":"Cable outer diameter ≤ 25 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Owalność kabla / Ovality\nZakres:\nZakres Średnica zewnętrzna kabla ≤ 25 mm\nRange Cable outer diameter ≤ 25 mm","reference":"ISO 19642-2:2019-01 (p. 6.1.2) | ISO 19642-2:2023 (p. 6.2.2) | ISO 19642-7:2019-01 (p. 6.2.2) | ISO 19642-8 2019-01 (p. 6.2.2) | ISO 19642-9:2019-01 (p. 6.2.2) | ISO 19642-10:2019-01 (p. 6.2.2) | ISO 14572:2011-10 (p. 5.2) | LV 212-1:2015-01 (p. 9.1.1) | LV 212-2:2015-01 (p. 9.1.1) | LV 216-2:2017-02 (p. 9.1.1) | VW 75209-1:2015-01 (p. 9.1.1) | VW 75209-1:2021-12 (p. 9.2.2) | VW 75209-2:2015-01 (p. 9.1.1) | VW 75209-2:2021-12 (p. 9.2.2) | VW 75210-1:2024-08 (p. 9.2.2) | VW 75210-2:2023-06 (p. 9.2.1) | MBN LV 212-1:2017-08 (p. 9.1.1) | MBN 50212-1:2023-04 (p. 12.2.2) | MBN LV 216-2:2017-07 (p. 9.1.1) | GS 95007-3-1:2015-08 (p. 9.1.1) | GS 95007-3-2:2015-09 (p. 9.1.1) | GS 95007-6-2:2017-04 (p. 9.1.1)","norm_bases":["ISO 19642-2:2019-01 (p. 6.1.2)","ISO 19642-2:2023 (p. 6.2.2)","ISO 19642-7:2019-01 (p. 6.2.2)","ISO 19642-8 2019-01 (p. 6.2.2)","ISO 19642-9:2019-01 (p. 6.2.2)","ISO 19642-10:2019-01 (p. 6.2.2)","ISO 14572:2011-10 (p. 5.2)","LV 212-1:2015-01 (p. 9.1.1)","LV 212-2:2015-01 (p. 9.1.1)","LV 216-2:2017-02 (p. 9.1.1)","VW 75209-1:2015-01 (p. 9.1.1)","VW 75209-1:2021-12 (p. 9.2.2)","VW 75209-2:2015-01 (p. 9.1.1)","VW 75209-2:2021-12 (p. 9.2.2)","VW 75210-1:2024-08 (p. 9.2.2)","VW 75210-2:2023-06 (p. 9.2.1)","MBN LV 212-1:2017-08 (p. 9.1.1)","MBN 50212-1:2023-04 (p. 12.2.2)","MBN LV 216-2:2017-07 (p. 9.1.1)","GS 95007-3-1:2015-08 (p. 9.1.1)","GS 95007-3-2:2015-09 (p. 9.1.1)","GS 95007-6-2:2017-04 (p. 9.1.1)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Owalność kabla / Ovality\nZakres:\nZakres Średnica zewnętrzna kabla ≤ 25 mm\nRange Cable outer diameter ≤ 25 mm ISO 19642-2:2019-01 (p. 6.1.2) | ISO 19642-2:2023 (p. 6.2.2) | ISO 19642-7:2019-01 (p. 6.2.2) | ISO 19642-8 2019-01 (p. 6.2.2) | ISO 19642-9:2019-01 (p. 6.2.2) | ISO 19642-10:2019-01 (p. 6.2.2) | ISO 14572:2011-10 (p. 5.2) | LV 212-1:2015-01 (p. 9.1.1) | LV 212-2:2015-01 (p. 9.1.1) | LV 216-2:2017-02 (p. 9.1.1) | VW 75209-1:2015-01 (p. 9.1.1) | VW 75209-1:2021-12 (p. 9.2.2) | VW 75209-2:2015-01 (p. 9.1.1) | VW 75209-2:2021-12 (p. 9.2.2) | VW 75210-1:2024-08 (p. 9.2.2) | VW 75210-2:2023-06 (p. 9.2.1) | MBN LV 212-1:2017-08 (p. 9.1.1) | MBN 50212-1:2023-04 (p. 12.2.2) | MBN LV 216-2:2017-07 (p. 9.1.1) | GS 95007-3-1:2015-08 (p. 9.1.1) | GS 95007-3-2:2015-09 (p. 9.1.1) | GS 95007-6-2:2017-04 (p. 9.1.1) Kable / Cables Owalnosc kabla / Ovality\nZakres:\nZakres Srednica zewnetrzna kabla ≤ 25 mm\nRange Cable outer diameter ≤ 25 mm ISO 19642-2:2019-01 (p. 6.1.2) | ISO 19642-2:2023 (p. 6.2.2) | ISO 19642-7:2019-01 (p. 6.2.2) | ISO 19642-8 2019-01 (p. 6.2.2) | ISO 19642-9:2019-01 (p. 6.2.2) | ISO 19642-10:2019-01 (p. 6.2.2) | ISO 14572:2011-10 (p. 5.2) | LV 212-1:2015-01 (p. 9.1.1) | LV 212-2:2015-01 (p. 9.1.1) | LV 216-2:2017-02 (p. 9.1.1) | VW 75209-1:2015-01 (p. 9.1.1) | VW 75209-1:2021-12 (p. 9.2.2) | VW 75209-2:2015-01 (p. 9.1.1) | VW 75209-2:2021-12 (p. 9.2.2) | VW 75210-1:2024-08 (p. 9.2.2) | VW 75210-2:2023-06 (p. 9.2.1) | MBN LV 212-1:2017-08 (p. 9.1.1) | MBN 50212-1:2023-04 (p. 12.2.2) | MBN LV 216-2:2017-07 (p. 9.1.1) | GS 95007-3-1:2015-08 (p. 9.1.1) | GS 95007-3-2:2015-09 (p. 9.1.1) | GS 95007-6-2:2017-04 (p. 9.1.1)","categories":["other"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d97c","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Badania wizualne: - kolor izolacji / powłoki - test wizualny kabla - kierunek skrętu żyły i kabli skręconych / Visual Tests: - color of insulation / sheath - cable visual test - twist direction of core / twisted cables","parameters":[{"name":"Tablice kolorów RAL","range":"9005, 5017, 8003, 7000, 6018, 2003, 3000, 4005, 1013, 1021, 5015, 1001, 6016, 3015"},{"name":"RAL color tables","range":"9005, 5017, 8003, 7000, 6018, 2003, 3000, 4005, 1013, 1021, 5015, 1001, 6016, 3015"}],"technique":null,"techniques":[],"computed":[],"activity":"Badania wizualne: - kolor izolacji / powłoki - test wizualny kabla - kierunek skrętu żyły i kabli skręconych / Visual Tests: - color of insulation / sheath - cable visual test - twist direction of core / twisted cables\nZakres:\nTablice kolorów RAL 9005, 5017, 8003, 7000, 6018, 2003, 3000, 4005, 1013, 1021, 5015, 1001, 6016, 3015\nRAL color tables 9005, 5017, 8003, 7000, 6018, 2003, 3000, 4005, 1013, 1021, 5015, 1001, 6016, 3015","reference":"LV 112-1:2013-04 (p. 7.3; 7.4.1) | LV 112-2:2013-04 (p. 7.3; 7.4.1) | LV 122:2015-05 (p. 9.4.1; 11.1.4) | LV 122:2016-02 (p. 9.4.1; 11.2.4) | LV 212-1:2015-01 (p. 7.3; 7.4.1) | LV 212-2:2015-01 (p. 7.3; 7.4.1) | LV 216-1:2015-07 (p. 7.3; 7.5.1) | LV 216-2:2017-02 (p. 7.3; 7.5.1) | VW 60306-1:2018-09-01 (p. 7.3; 7.4.1) | VW 60306-1:2021-10 (p. 7.2; 7.3; 7.4.1) | VW 60306-2:2013-04 (p. 7.3; 7.4.1) | VW 60306-2:2021-11 (p. 7.3; 7.4.1) | VW 60306-4:2021-12 (p. 7.2; 7.3; 7.4.1) | VW 75205:2019-11 (p. 9.4.1; 11.1.4) | VW 75205:2023-05 (p. 9.2; 9.4.1; 11.1.4) | VW 75205:2024-04 (p. 11.2.5) | VW 75209-1:2015-01 (p. 7.3; 7.4.1) | VW 75209-1:2021-12 (p. 7.2; 7.3; 7.4.1) | VW 75209-2:2015-01 (p. 7.3; 7.4.1) | VW 75209-2:2021-12 (p. 7.2; 7.3; 7.4.1) | VW 75210-1:2023-06 (p. 7.2; 7.3; 7.4.1) | VW 75210-1:2024-08 (p. 7.2; 7.3; 7.4.1) | VW 75210-2:2023-06 (p. 7.2; 7.3; 7.4.1) | MBN LV 112-1:2016-03 (p. 7.3; 7.4.1) | MBN 50112-1:2023-06 (p. 10.3; 10.4.2) | MBN 50112-2: 2023-05 (p. 10.3; 10.4.1) | MBN 50216-1:2023-07 (p. 10.3; 10.5.2) | MBN LV 212-1:2017-08 (p. 7.3; 7.4.1) | MBN 50212-1:2023-04 (p. 10.2; 10.3.1; 10.3.2; 10.4.2) | MBN LV 122:2017-06 (p. 9.4.1; 11.2.4) | MBN 50122:2023-07 (p. 11.4.1; 13.2.5) | MBN LV 216-2:2017-07 (p. 7.3; 7.5.1) | MBN 50112-4:2024-06 (p. 10.3; 10.4.2) | GS 95007-1-1:2013-05 (p. 7.3; 7.4.1) | GS 95007-1-2:2013-05 (p. 7.3; 7.4.1) | GS 95007-1-5:2015-07 (p. 9.4.1; 11.1.4) | GS 95007-3-1:2015-08 (p. 7.3; 7.4.1) | GS 95007-3-2:2015-09 (p. 7.3; 7.4.1) | GS 95007-6-1:2016-03 (p. 7.3; 7.5.1) | GS 95007-6-2:2017-04 (p. 7.3; 7.5.1) | ISO 14572:2011-10 (p. 4.7)","norm_bases":["LV 112-1:2013-04 (p. 7.3; 7.4.1)","LV 112-2:2013-04 (p. 7.3; 7.4.1)","LV 122:2015-05 (p. 9.4.1; 11.1.4)","LV 122:2016-02 (p. 9.4.1; 11.2.4)","LV 212-1:2015-01 (p. 7.3; 7.4.1)","LV 212-2:2015-01 (p. 7.3; 7.4.1)","LV 216-1:2015-07 (p. 7.3; 7.5.1)","LV 216-2:2017-02 (p. 7.3; 7.5.1)","VW 60306-1:2018-09-01 (p. 7.3; 7.4.1)","VW 60306-1:2021-10 (p. 7.2; 7.3; 7.4.1)","VW 60306-2:2013-04 (p. 7.3; 7.4.1)","VW 60306-2:2021-11 (p. 7.3; 7.4.1)","VW 60306-4:2021-12 (p. 7.2; 7.3; 7.4.1)","VW 75205:2019-11 (p. 9.4.1; 11.1.4)","VW 75205:2023-05 (p. 9.2; 9.4.1; 11.1.4)","VW 75205:2024-04 (p. 11.2.5)","VW 75209-1:2015-01 (p. 7.3; 7.4.1)","VW 75209-1:2021-12 (p. 7.2; 7.3; 7.4.1)","VW 75209-2:2015-01 (p. 7.3; 7.4.1)","VW 75209-2:2021-12 (p. 7.2; 7.3; 7.4.1)","VW 75210-1:2023-06 (p. 7.2; 7.3; 7.4.1)","VW 75210-1:2024-08 (p. 7.2; 7.3; 7.4.1)","VW 75210-2:2023-06 (p. 7.2; 7.3; 7.4.1)","MBN LV 112-1:2016-03 (p. 7.3; 7.4.1)","MBN 50112-1:2023-06 (p. 10.3; 10.4.2)","MBN 50112-2: 2023-05 (p. 10.3; 10.4.1)","MBN 50216-1:2023-07 (p. 10.3; 10.5.2)","MBN LV 212-1:2017-08 (p. 7.3; 7.4.1)","MBN 50212-1:2023-04 (p. 10.2; 10.3.1; 10.3.2; 10.4.2)","MBN LV 122:2017-06 (p. 9.4.1; 11.2.4)","MBN 50122:2023-07 (p. 11.4.1; 13.2.5)","MBN LV 216-2:2017-07 (p. 7.3; 7.5.1)","MBN 50112-4:2024-06 (p. 10.3; 10.4.2)","GS 95007-1-1:2013-05 (p. 7.3; 7.4.1)","GS 95007-1-2:2013-05 (p. 7.3; 7.4.1)","GS 95007-1-5:2015-07 (p. 9.4.1; 11.1.4)","GS 95007-3-1:2015-08 (p. 7.3; 7.4.1)","GS 95007-3-2:2015-09 (p. 7.3; 7.4.1)","GS 95007-6-1:2016-03 (p. 7.3; 7.5.1)","GS 95007-6-2:2017-04 (p. 7.3; 7.5.1)","ISO 14572:2011-10 (p. 4.7)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Badania wizualne: - kolor izolacji / powłoki - test wizualny kabla - kierunek skrętu żyły i kabli skręconych / Visual Tests: - color of insulation / sheath - cable visual test - twist direction of core / twisted cables\nZakres:\nTablice kolorów RAL 9005, 5017, 8003, 7000, 6018, 2003, 3000, 4005, 1013, 1021, 5015, 1001, 6016, 3015\nRAL color tables 9005, 5017, 8003, 7000, 6018, 2003, 3000, 4005, 1013, 1021, 5015, 1001, 6016, 3015 LV 112-1:2013-04 (p. 7.3; 7.4.1) | LV 112-2:2013-04 (p. 7.3; 7.4.1) | LV 122:2015-05 (p. 9.4.1; 11.1.4) | LV 122:2016-02 (p. 9.4.1; 11.2.4) | LV 212-1:2015-01 (p. 7.3; 7.4.1) | LV 212-2:2015-01 (p. 7.3; 7.4.1) | LV 216-1:2015-07 (p. 7.3; 7.5.1) | LV 216-2:2017-02 (p. 7.3; 7.5.1) | VW 60306-1:2018-09-01 (p. 7.3; 7.4.1) | VW 60306-1:2021-10 (p. 7.2; 7.3; 7.4.1) | VW 60306-2:2013-04 (p. 7.3; 7.4.1) | VW 60306-2:2021-11 (p. 7.3; 7.4.1) | VW 60306-4:2021-12 (p. 7.2; 7.3; 7.4.1) | VW 75205:2019-11 (p. 9.4.1; 11.1.4) | VW 75205:2023-05 (p. 9.2; 9.4.1; 11.1.4) | VW 75205:2024-04 (p. 11.2.5) | VW 75209-1:2015-01 (p. 7.3; 7.4.1) | VW 75209-1:2021-12 (p. 7.2; 7.3; 7.4.1) | VW 75209-2:2015-01 (p. 7.3; 7.4.1) | VW 75209-2:2021-12 (p. 7.2; 7.3; 7.4.1) | VW 75210-1:2023-06 (p. 7.2; 7.3; 7.4.1) | VW 75210-1:2024-08 (p. 7.2; 7.3; 7.4.1) | VW 75210-2:2023-06 (p. 7.2; 7.3; 7.4.1) | MBN LV 112-1:2016-03 (p. 7.3; 7.4.1) | MBN 50112-1:2023-06 (p. 10.3; 10.4.2) | MBN 50112-2: 2023-05 (p. 10.3; 10.4.1) | MBN 50216-1:2023-07 (p. 10.3; 10.5.2) | MBN LV 212-1:2017-08 (p. 7.3; 7.4.1) | MBN 50212-1:2023-04 (p. 10.2; 10.3.1; 10.3.2; 10.4.2) | MBN LV 122:2017-06 (p. 9.4.1; 11.2.4) | MBN 50122:2023-07 (p. 11.4.1; 13.2.5) | MBN LV 216-2:2017-07 (p. 7.3; 7.5.1) | MBN 50112-4:2024-06 (p. 10.3; 10.4.2) | GS 95007-1-1:2013-05 (p. 7.3; 7.4.1) | GS 95007-1-2:2013-05 (p. 7.3; 7.4.1) | GS 95007-1-5:2015-07 (p. 9.4.1; 11.1.4) | GS 95007-3-1:2015-08 (p. 7.3; 7.4.1) | GS 95007-3-2:2015-09 (p. 7.3; 7.4.1) | GS 95007-6-1:2016-03 (p. 7.3; 7.5.1) | GS 95007-6-2:2017-04 (p. 7.3; 7.5.1) | ISO 14572:2011-10 (p. 4.7) Kable / Cables Badania wizualne: - kolor izolacji / powloki - test wizualny kabla - kierunek skretu zyly i kabli skreconych / Visual Tests: - color of insulation / sheath - cable visual test - twist direction of core / twisted cables\nZakres:\nTablice kolorow RAL 9005, 5017, 8003, 7000, 6018, 2003, 3000, 4005, 1013, 1021, 5015, 1001, 6016, 3015\nRAL color tables 9005, 5017, 8003, 7000, 6018, 2003, 3000, 4005, 1013, 1021, 5015, 1001, 6016, 3015 LV 112-1:2013-04 (p. 7.3; 7.4.1) | LV 112-2:2013-04 (p. 7.3; 7.4.1) | LV 122:2015-05 (p. 9.4.1; 11.1.4) | LV 122:2016-02 (p. 9.4.1; 11.2.4) | LV 212-1:2015-01 (p. 7.3; 7.4.1) | LV 212-2:2015-01 (p. 7.3; 7.4.1) | LV 216-1:2015-07 (p. 7.3; 7.5.1) | LV 216-2:2017-02 (p. 7.3; 7.5.1) | VW 60306-1:2018-09-01 (p. 7.3; 7.4.1) | VW 60306-1:2021-10 (p. 7.2; 7.3; 7.4.1) | VW 60306-2:2013-04 (p. 7.3; 7.4.1) | VW 60306-2:2021-11 (p. 7.3; 7.4.1) | VW 60306-4:2021-12 (p. 7.2; 7.3; 7.4.1) | VW 75205:2019-11 (p. 9.4.1; 11.1.4) | VW 75205:2023-05 (p. 9.2; 9.4.1; 11.1.4) | VW 75205:2024-04 (p. 11.2.5) | VW 75209-1:2015-01 (p. 7.3; 7.4.1) | VW 75209-1:2021-12 (p. 7.2; 7.3; 7.4.1) | VW 75209-2:2015-01 (p. 7.3; 7.4.1) | VW 75209-2:2021-12 (p. 7.2; 7.3; 7.4.1) | VW 75210-1:2023-06 (p. 7.2; 7.3; 7.4.1) | VW 75210-1:2024-08 (p. 7.2; 7.3; 7.4.1) | VW 75210-2:2023-06 (p. 7.2; 7.3; 7.4.1) | MBN LV 112-1:2016-03 (p. 7.3; 7.4.1) | MBN 50112-1:2023-06 (p. 10.3; 10.4.2) | MBN 50112-2: 2023-05 (p. 10.3; 10.4.1) | MBN 50216-1:2023-07 (p. 10.3; 10.5.2) | MBN LV 212-1:2017-08 (p. 7.3; 7.4.1) | MBN 50212-1:2023-04 (p. 10.2; 10.3.1; 10.3.2; 10.4.2) | MBN LV 122:2017-06 (p. 9.4.1; 11.2.4) | MBN 50122:2023-07 (p. 11.4.1; 13.2.5) | MBN LV 216-2:2017-07 (p. 7.3; 7.5.1) | MBN 50112-4:2024-06 (p. 10.3; 10.4.2) | GS 95007-1-1:2013-05 (p. 7.3; 7.4.1) | GS 95007-1-2:2013-05 (p. 7.3; 7.4.1) | GS 95007-1-5:2015-07 (p. 9.4.1; 11.1.4) | GS 95007-3-1:2015-08 (p. 7.3; 7.4.1) | GS 95007-3-2:2015-09 (p. 7.3; 7.4.1) | GS 95007-6-1:2016-03 (p. 7.3; 7.5.1) | GS 95007-6-2:2017-04 (p. 7.3; 7.5.1) | ISO 14572:2011-10 (p. 4.7)","categories":["construction"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d97d","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Określenie wytrzymałości na rozciąganie i wydłużenie przy zrywaniu: - w temperaturze pokojowej - po krótkotrwałym starzeniu - po długotrwałym starzeniu / Determining the tensile strength and elongation at tear: - at RT - after short-therm aging - after long-term aging","parameters":[{"name":"Maszyna wytrzymałościowa","range":"do 20 kN"},{"name":"Ekstensometr","range":"do 600 mm"},{"name":"Aging Oven","range":"up to 200 °C (± 2 °C)"},{"name":"Tensile machine","range":"up to 20 kN"},{"name":"Extensometer","range":"up to 600 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Określenie wytrzymałości na rozciąganie i wydłużenie przy zrywaniu: - w temperaturze pokojowej - po krótkotrwałym starzeniu - po długotrwałym starzeniu / Determining the tensile strength and elongation at tear: - at RT - after short-therm aging - after long-term aging\nZakres:\nMaszyna wytrzymałościowa do 20 kN\nEkstensometr do 600 mm\nAging Oven up to 200 °C (± 2 °C)\nTensile machine up to 20 kN\nExtensometer up to 600 mm","reference":"LV 112-1:2013-04 (p. 9.2.7; 9.6.7.3; 9.6.8.3) | LV 112-1:2014-04 (p. 9.2.7; 9.6.7.3; 9.6.8.3) | LV 112-2:2013-04 (p. 9.2; 9.6.7.3; 9.6.8.3) | LV 212-1:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | LV 212-2:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | LV 216-1:2015-07 (p. 9.2.7; 9.6.7.3; 9.6.8.3) | LV 216-2: 2017-02 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | VW 60306-1:2018-09-01 (p. 9.2.3) | VW 60306-1:2021-10 (p. 9.3.4) | VW 60306-2:2013-04 (p. 9.2; 9.6.7.3; 9.6.8.3) | VW 60306-2:2021-11 (p. 9.3.4) | VW 60306-4:2021-12 (p. 9.3.4) | VW 75209-1:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | VW 75209-1:2021-12 (p. 9.3.4) | VW 75209-2:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | VW 75209-2:2021-12 (p. 9.3.3) | VW 75210-1:2023-06 (p. 9.3.5) | VW 75210-1:2024-08 (p. 9.3.5) | VW 75210-2:2023-06 (p. 9.3.5) | MBN LV 112-1:2016-03 (p. 9.2.7; 9.6.7.3; 9.6.8.3) | MBN 50112-1:2023-06 (p. 12.2.8; 12.6.7.4; 12.6.8.4) | MBN 50216-1:2023-07 (p. 12.3.7; 12.7.6.4; 12.7.7.4) | MBN LV 212-1:2017-08 | MBN 50212-1:2023-04 (p. 12.3.8; 12.7.6.4; 12.7.8.4) (p. 9.2.7; 9.6.6.3; 9.6.7.3) | MBN LV 216-2:2017-07 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | MBN 50112-4:2024-06 (p. 12.2.8; 12.2.8.1; 12.2.8.2; 12.6.7.3; 12.6.8.3) | GS 95007-1-1:2013-05 (p. 9.2.7; 9.6.7.3; 9.6.8.3) | GS 95007-1-2:2013-05 (p. 9.2; 9.6.7.3; 9.6.8.3) | GS 95007-3-1:2015-08 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | GS 95007-3-2:2015-09 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | GS 95007-6-1:2016-03 (p. 9.2.7; 9.6.7.3; 9.6.8.3) | GS 95007-6-2:2017-04 (p. 9.2.7; 9.6.6.3; 9.6.7.3)","norm_bases":["LV 112-1:2013-04 (p. 9.2.7; 9.6.7.3; 9.6.8.3)","LV 112-1:2014-04 (p. 9.2.7; 9.6.7.3; 9.6.8.3)","LV 112-2:2013-04 (p. 9.2; 9.6.7.3; 9.6.8.3)","LV 212-1:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3)","LV 212-2:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3)","LV 216-1:2015-07 (p. 9.2.7; 9.6.7.3; 9.6.8.3)","LV 216-2: 2017-02 (p. 9.2.7; 9.6.6.3; 9.6.7.3)","VW 60306-1:2018-09-01 (p. 9.2.3)","VW 60306-1:2021-10 (p. 9.3.4)","VW 60306-2:2013-04 (p. 9.2; 9.6.7.3; 9.6.8.3)","VW 60306-2:2021-11 (p. 9.3.4)","VW 60306-4:2021-12 (p. 9.3.4)","VW 75209-1:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3)","VW 75209-1:2021-12 (p. 9.3.4)","VW 75209-2:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3)","VW 75209-2:2021-12 (p. 9.3.3)","VW 75210-1:2023-06 (p. 9.3.5)","VW 75210-1:2024-08 (p. 9.3.5)","VW 75210-2:2023-06 (p. 9.3.5)","MBN LV 112-1:2016-03 (p. 9.2.7; 9.6.7.3; 9.6.8.3)","MBN 50112-1:2023-06 (p. 12.2.8; 12.6.7.4; 12.6.8.4)","MBN 50216-1:2023-07 (p. 12.3.7; 12.7.6.4; 12.7.7.4)","MBN LV 212-1:2017-08","MBN 50212-1:2023-04 (p. 12.3.8; 12.7.6.4; 12.7.8.4) (p. 9.2.7; 9.6.6.3; 9.6.7.3)","MBN LV 216-2:2017-07 (p. 9.2.7; 9.6.6.3; 9.6.7.3)","MBN 50112-4:2024-06 (p. 12.2.8; 12.2.8.1; 12.2.8.2; 12.6.7.3; 12.6.8.3)","GS 95007-1-1:2013-05 (p. 9.2.7; 9.6.7.3; 9.6.8.3)","GS 95007-1-2:2013-05 (p. 9.2; 9.6.7.3; 9.6.8.3)","GS 95007-3-1:2015-08 (p. 9.2.7; 9.6.6.3; 9.6.7.3)","GS 95007-3-2:2015-09 (p. 9.2.7; 9.6.6.3; 9.6.7.3)","GS 95007-6-1:2016-03 (p. 9.2.7; 9.6.7.3; 9.6.8.3)","GS 95007-6-2:2017-04 (p. 9.2.7; 9.6.6.3; 9.6.7.3)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Określenie wytrzymałości na rozciąganie i wydłużenie przy zrywaniu: - w temperaturze pokojowej - po krótkotrwałym starzeniu - po długotrwałym starzeniu / Determining the tensile strength and elongation at tear: - at RT - after short-therm aging - after long-term aging\nZakres:\nMaszyna wytrzymałościowa do 20 kN\nEkstensometr do 600 mm\nAging Oven up to 200 °C (± 2 °C)\nTensile machine up to 20 kN\nExtensometer up to 600 mm LV 112-1:2013-04 (p. 9.2.7; 9.6.7.3; 9.6.8.3) | LV 112-1:2014-04 (p. 9.2.7; 9.6.7.3; 9.6.8.3) | LV 112-2:2013-04 (p. 9.2; 9.6.7.3; 9.6.8.3) | LV 212-1:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | LV 212-2:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | LV 216-1:2015-07 (p. 9.2.7; 9.6.7.3; 9.6.8.3) | LV 216-2: 2017-02 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | VW 60306-1:2018-09-01 (p. 9.2.3) | VW 60306-1:2021-10 (p. 9.3.4) | VW 60306-2:2013-04 (p. 9.2; 9.6.7.3; 9.6.8.3) | VW 60306-2:2021-11 (p. 9.3.4) | VW 60306-4:2021-12 (p. 9.3.4) | VW 75209-1:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | VW 75209-1:2021-12 (p. 9.3.4) | VW 75209-2:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | VW 75209-2:2021-12 (p. 9.3.3) | VW 75210-1:2023-06 (p. 9.3.5) | VW 75210-1:2024-08 (p. 9.3.5) | VW 75210-2:2023-06 (p. 9.3.5) | MBN LV 112-1:2016-03 (p. 9.2.7; 9.6.7.3; 9.6.8.3) | MBN 50112-1:2023-06 (p. 12.2.8; 12.6.7.4; 12.6.8.4) | MBN 50216-1:2023-07 (p. 12.3.7; 12.7.6.4; 12.7.7.4) | MBN LV 212-1:2017-08 | MBN 50212-1:2023-04 (p. 12.3.8; 12.7.6.4; 12.7.8.4) (p. 9.2.7; 9.6.6.3; 9.6.7.3) | MBN LV 216-2:2017-07 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | MBN 50112-4:2024-06 (p. 12.2.8; 12.2.8.1; 12.2.8.2; 12.6.7.3; 12.6.8.3) | GS 95007-1-1:2013-05 (p. 9.2.7; 9.6.7.3; 9.6.8.3) | GS 95007-1-2:2013-05 (p. 9.2; 9.6.7.3; 9.6.8.3) | GS 95007-3-1:2015-08 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | GS 95007-3-2:2015-09 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | GS 95007-6-1:2016-03 (p. 9.2.7; 9.6.7.3; 9.6.8.3) | GS 95007-6-2:2017-04 (p. 9.2.7; 9.6.6.3; 9.6.7.3) Kable / Cables Okreslenie wytrzymalosci na rozciaganie i wydluzenie przy zrywaniu: - w temperaturze pokojowej - po krotkotrwalym starzeniu - po dlugotrwalym starzeniu / Determining the tensile strength and elongation at tear: - at RT - after short-therm aging - after long-term aging\nZakres:\nMaszyna wytrzymalosciowa do 20 kN\nEkstensometr do 600 mm\nAging Oven up to 200 °C (± 2 °C)\nTensile machine up to 20 kN\nExtensometer up to 600 mm LV 112-1:2013-04 (p. 9.2.7; 9.6.7.3; 9.6.8.3) | LV 112-1:2014-04 (p. 9.2.7; 9.6.7.3; 9.6.8.3) | LV 112-2:2013-04 (p. 9.2; 9.6.7.3; 9.6.8.3) | LV 212-1:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | LV 212-2:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | LV 216-1:2015-07 (p. 9.2.7; 9.6.7.3; 9.6.8.3) | LV 216-2: 2017-02 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | VW 60306-1:2018-09-01 (p. 9.2.3) | VW 60306-1:2021-10 (p. 9.3.4) | VW 60306-2:2013-04 (p. 9.2; 9.6.7.3; 9.6.8.3) | VW 60306-2:2021-11 (p. 9.3.4) | VW 60306-4:2021-12 (p. 9.3.4) | VW 75209-1:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | VW 75209-1:2021-12 (p. 9.3.4) | VW 75209-2:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | VW 75209-2:2021-12 (p. 9.3.3) | VW 75210-1:2023-06 (p. 9.3.5) | VW 75210-1:2024-08 (p. 9.3.5) | VW 75210-2:2023-06 (p. 9.3.5) | MBN LV 112-1:2016-03 (p. 9.2.7; 9.6.7.3; 9.6.8.3) | MBN 50112-1:2023-06 (p. 12.2.8; 12.6.7.4; 12.6.8.4) | MBN 50216-1:2023-07 (p. 12.3.7; 12.7.6.4; 12.7.7.4) | MBN LV 212-1:2017-08 | MBN 50212-1:2023-04 (p. 12.3.8; 12.7.6.4; 12.7.8.4) (p. 9.2.7; 9.6.6.3; 9.6.7.3) | MBN LV 216-2:2017-07 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | MBN 50112-4:2024-06 (p. 12.2.8; 12.2.8.1; 12.2.8.2; 12.6.7.3; 12.6.8.3) | GS 95007-1-1:2013-05 (p. 9.2.7; 9.6.7.3; 9.6.8.3) | GS 95007-1-2:2013-05 (p. 9.2; 9.6.7.3; 9.6.8.3) | GS 95007-3-1:2015-08 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | GS 95007-3-2:2015-09 (p. 9.2.7; 9.6.6.3; 9.6.7.3) | GS 95007-6-1:2016-03 (p. 9.2.7; 9.6.7.3; 9.6.8.3) | GS 95007-6-2:2017-04 (p. 9.2.7; 9.6.6.3; 9.6.7.3)","categories":["other"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d97e","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Wskaźnik ściągalności izolacji (A-faktor) / Insulation strippability factor (A-factor)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik ściągalności izolacji (A-faktor) / Insulation strippability factor (A-factor)","reference":"VW 60306-1:2018-09-01 (p. 9.1.4) | VW 60306-1:2021-10 (p. 9.2.5) | VW 60306-4:2021-12 (p. 9.2.5)","norm_bases":["VW 60306-1:2018-09-01 (p. 9.1.4)","VW 60306-1:2021-10 (p. 9.2.5)","VW 60306-4:2021-12 (p. 9.2.5)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Wskaźnik ściągalności izolacji (A-faktor) / Insulation strippability factor (A-factor) VW 60306-1:2018-09-01 (p. 9.1.4) | VW 60306-1:2021-10 (p. 9.2.5) | VW 60306-4:2021-12 (p. 9.2.5) Kable / Cables Wskaznik sciagalnosci izolacji (A-faktor) / Insulation strippability factor (A-factor) VW 60306-1:2018-09-01 (p. 9.1.4) | VW 60306-1:2021-10 (p. 9.2.5) | VW 60306-4:2021-12 (p. 9.2.5)","categories":["construction"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d97f","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Wyznaczenie stopnia usieciowania / Determining the degree of cross-linking","parameters":[{"name":"Piec","range":"do 200 °C (± 2 °C)"},{"name":"Aging Oven","range":"up to 200 °C (± 2 °C)"}],"technique":null,"techniques":[],"computed":[],"activity":"Wyznaczenie stopnia usieciowania / Determining the degree of cross-linking\nZakres:\nPiec do 200 °C (± 2 °C)\nAging Oven up to 200 °C (± 2 °C)","reference":"DIN EN 60811-507:2012-12 | DIN EN 60811-2-1:2002-09 | LV 112-1:2013-04 (p. 9.2.9) | LV 112-1:2014-04 (p. 9.2.9) | LV 112-2:2013-04 (p. 9.2) | LV 212-1:2015-01 (p. 9.2.9) | LV 212-2:2015-01 (p. 9.2.9) | LV 216-1:2015-07 (p. 9.2.9) | LV 216-2:2017-02 (p. 9.2.9) | VW 60306-1:2018-09-01 (p. 9.2.5) | VW 60306-1:2021-10 (p. 9.3.6) | VW 60306-2:2013-04 (p. 9.2) | VW 60306-2:2021-11 (p. 9.3.6) | VW 60306-4:2021-12 (p. 9.3.6) | VW 75209-1:2015-01 (p. 9.2.9) | VW 75209-1:2021-12 (p. 9.3.6) | VW 75209-2:2015-01 (p. 9.2.9) | VW 75209-2:2021-12 (p. 9.3.5) | VW 75210-1:2023-06 (p. 9.3.7) | VW 75210-1:2024-08 (p. 9.3.7) | VW 75210-2:2023-06 (p. 9.3.7) | MBN LV 112-1:2016-03 (p. 9.2.9) | MBN 50112-1:2023-06 (p. 12.2.10) | MBN 50216-1:2023-07 (p. 12.3.10) | MBN LV 212-1:2017-08 (p. 9.2.9) | MBN 50212-1:2023-04 (p. 12.3.10) | MBN LV 216-2:2017-07 (p. 9.2.9) | MBN 50112-4:2024-06 (p. 12.2.10) | GS 95007-1-1:2013-05 (p. 9.2.9) | GS 95007-1-2:2013-05 (p. 9.2) | GS 95007-3-1:2015-08 (p. 9.2.9) | GS 95007-3-2:2015-09 (p. 9.2.9) | GS 95007-6-1:2016-03 (p. 9.2.9) | GS 95007-6-2:2017-04 (p. 9.2.9)","norm_bases":["DIN EN 60811-507:2012-12","DIN EN 60811-2-1:2002-09","LV 112-1:2013-04 (p. 9.2.9)","LV 112-1:2014-04 (p. 9.2.9)","LV 112-2:2013-04 (p. 9.2)","LV 212-1:2015-01 (p. 9.2.9)","LV 212-2:2015-01 (p. 9.2.9)","LV 216-1:2015-07 (p. 9.2.9)","LV 216-2:2017-02 (p. 9.2.9)","VW 60306-1:2018-09-01 (p. 9.2.5)","VW 60306-1:2021-10 (p. 9.3.6)","VW 60306-2:2013-04 (p. 9.2)","VW 60306-2:2021-11 (p. 9.3.6)","VW 60306-4:2021-12 (p. 9.3.6)","VW 75209-1:2015-01 (p. 9.2.9)","VW 75209-1:2021-12 (p. 9.3.6)","VW 75209-2:2015-01 (p. 9.2.9)","VW 75209-2:2021-12 (p. 9.3.5)","VW 75210-1:2023-06 (p. 9.3.7)","VW 75210-1:2024-08 (p. 9.3.7)","VW 75210-2:2023-06 (p. 9.3.7)","MBN LV 112-1:2016-03 (p. 9.2.9)","MBN 50112-1:2023-06 (p. 12.2.10)","MBN 50216-1:2023-07 (p. 12.3.10)","MBN LV 212-1:2017-08 (p. 9.2.9)","MBN 50212-1:2023-04 (p. 12.3.10)","MBN LV 216-2:2017-07 (p. 9.2.9)","MBN 50112-4:2024-06 (p. 12.2.10)","GS 95007-1-1:2013-05 (p. 9.2.9)","GS 95007-1-2:2013-05 (p. 9.2)","GS 95007-3-1:2015-08 (p. 9.2.9)","GS 95007-3-2:2015-09 (p. 9.2.9)","GS 95007-6-1:2016-03 (p. 9.2.9)","GS 95007-6-2:2017-04 (p. 9.2.9)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Wyznaczenie stopnia usieciowania / Determining the degree of cross-linking\nZakres:\nPiec do 200 °C (± 2 °C)\nAging Oven up to 200 °C (± 2 °C) DIN EN 60811-507:2012-12 | DIN EN 60811-2-1:2002-09 | LV 112-1:2013-04 (p. 9.2.9) | LV 112-1:2014-04 (p. 9.2.9) | LV 112-2:2013-04 (p. 9.2) | LV 212-1:2015-01 (p. 9.2.9) | LV 212-2:2015-01 (p. 9.2.9) | LV 216-1:2015-07 (p. 9.2.9) | LV 216-2:2017-02 (p. 9.2.9) | VW 60306-1:2018-09-01 (p. 9.2.5) | VW 60306-1:2021-10 (p. 9.3.6) | VW 60306-2:2013-04 (p. 9.2) | VW 60306-2:2021-11 (p. 9.3.6) | VW 60306-4:2021-12 (p. 9.3.6) | VW 75209-1:2015-01 (p. 9.2.9) | VW 75209-1:2021-12 (p. 9.3.6) | VW 75209-2:2015-01 (p. 9.2.9) | VW 75209-2:2021-12 (p. 9.3.5) | VW 75210-1:2023-06 (p. 9.3.7) | VW 75210-1:2024-08 (p. 9.3.7) | VW 75210-2:2023-06 (p. 9.3.7) | MBN LV 112-1:2016-03 (p. 9.2.9) | MBN 50112-1:2023-06 (p. 12.2.10) | MBN 50216-1:2023-07 (p. 12.3.10) | MBN LV 212-1:2017-08 (p. 9.2.9) | MBN 50212-1:2023-04 (p. 12.3.10) | MBN LV 216-2:2017-07 (p. 9.2.9) | MBN 50112-4:2024-06 (p. 12.2.10) | GS 95007-1-1:2013-05 (p. 9.2.9) | GS 95007-1-2:2013-05 (p. 9.2) | GS 95007-3-1:2015-08 (p. 9.2.9) | GS 95007-3-2:2015-09 (p. 9.2.9) | GS 95007-6-1:2016-03 (p. 9.2.9) | GS 95007-6-2:2017-04 (p. 9.2.9) Kable / Cables Wyznaczenie stopnia usieciowania / Determining the degree of cross-linking\nZakres:\nPiec do 200 °C (± 2 °C)\nAging Oven up to 200 °C (± 2 °C) DIN EN 60811-507:2012-12 | DIN EN 60811-2-1:2002-09 | LV 112-1:2013-04 (p. 9.2.9) | LV 112-1:2014-04 (p. 9.2.9) | LV 112-2:2013-04 (p. 9.2) | LV 212-1:2015-01 (p. 9.2.9) | LV 212-2:2015-01 (p. 9.2.9) | LV 216-1:2015-07 (p. 9.2.9) | LV 216-2:2017-02 (p. 9.2.9) | VW 60306-1:2018-09-01 (p. 9.2.5) | VW 60306-1:2021-10 (p. 9.3.6) | VW 60306-2:2013-04 (p. 9.2) | VW 60306-2:2021-11 (p. 9.3.6) | VW 60306-4:2021-12 (p. 9.3.6) | VW 75209-1:2015-01 (p. 9.2.9) | VW 75209-1:2021-12 (p. 9.3.6) | VW 75209-2:2015-01 (p. 9.2.9) | VW 75209-2:2021-12 (p. 9.3.5) | VW 75210-1:2023-06 (p. 9.3.7) | VW 75210-1:2024-08 (p. 9.3.7) | VW 75210-2:2023-06 (p. 9.3.7) | MBN LV 112-1:2016-03 (p. 9.2.9) | MBN 50112-1:2023-06 (p. 12.2.10) | MBN 50216-1:2023-07 (p. 12.3.10) | MBN LV 212-1:2017-08 (p. 9.2.9) | MBN 50212-1:2023-04 (p. 12.3.10) | MBN LV 216-2:2017-07 (p. 9.2.9) | MBN 50112-4:2024-06 (p. 12.2.10) | GS 95007-1-1:2013-05 (p. 9.2.9) | GS 95007-1-2:2013-05 (p. 9.2) | GS 95007-3-1:2015-08 (p. 9.2.9) | GS 95007-3-2:2015-09 (p. 9.2.9) | GS 95007-6-1:2016-03 (p. 9.2.9) | GS 95007-6-2:2017-04 (p. 9.2.9)","categories":["other"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d980","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Siła zginania kabla / Bending force of the cable","parameters":[{"name":"Maszyna wytrzymałościowa","range":"do 20 kN"},{"name":"Tensile machine","range":"up to 20 kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Siła zginania kabla / Bending force of the cable\nZakres:\nMaszyna wytrzymałościowa do 20 kN\nTensile machine up to 20 kN","reference":"LV 112-1:2013-04 (p. 9.3.4) | LV 112-1:2014-04 (p. 9.3.4) | LV 112-2:2007-11 (p. 8.4.5) | LV 112-2:2013-04 (p. 9.3.4) | LV 212-1:2015-01 (p. 9.3.4) | LV 212-2:2015-01 (p. 9.3.4) | LV 216-1:2015-07 (p. 9.3.4) | LV 216-2:2017-02 (p. 9.3.4) | VW 60306-1:2018-09-01 (p. 9.3.3) | VW 60306-1:2021-10 (p. 9.4.3) | VW 60306-2:2013-04 (p. 9.3.4) | VW 60306-2:2021-11 (p. 9.4.3) | VW 60306-4:2021-12 (p. 9.4.3) | VW 75209-1:2015-01 (p. 9.3.4) | VW 75209-1:2021-12 (p. 9.4.3) | VW 75209-2:2015-01 (p. 9.3.4) | VW 75209-2:2021-12 (p. 9.4.2) | VW 75210-1:2023-06 (p. 9.4.3) | VW 75210-1:2024-08 (p. 9.4.3) | VW 75210-2:2023-06 (p. 9.4.3) | MBN LV 112-1:2016-03 (p. 9.3.4) | MBN 50112-1:2023-06 (p. 12.3.5) | MBN LV 112-2:2012-01 (p. 8.4.5) | MBN 50112-2:2023-05 (p. 12.4.5) | MBN 50216-1:2023-07 (p. 12.4.5) | MBN LV 212-1:2017-08 (p. 9.3.4) | MBN 50212-1:2023-04 (p. 12.4.4) | MBN LV 216-2:2017-07 (p. 9.3.4) | MBN 50112-4:2024-06 (p. 12.3.6) | GS 95007-1-1:2013-05 (p. 9.3.4) | GS 95007-1-2:2013-05 (p. 9.3.4) | GS 95007-3-1:2015-08 (p. 9.3.4) | GS 95007-3-2:2015-09 (p. 9.3.4) | GS 95007-6-1:2016-03 (p. 9.3.4) | GS 95007-6-2:2017-04 (p. 9.3.4)","norm_bases":["LV 112-1:2013-04 (p. 9.3.4)","LV 112-1:2014-04 (p. 9.3.4)","LV 112-2:2007-11 (p. 8.4.5)","LV 112-2:2013-04 (p. 9.3.4)","LV 212-1:2015-01 (p. 9.3.4)","LV 212-2:2015-01 (p. 9.3.4)","LV 216-1:2015-07 (p. 9.3.4)","LV 216-2:2017-02 (p. 9.3.4)","VW 60306-1:2018-09-01 (p. 9.3.3)","VW 60306-1:2021-10 (p. 9.4.3)","VW 60306-2:2013-04 (p. 9.3.4)","VW 60306-2:2021-11 (p. 9.4.3)","VW 60306-4:2021-12 (p. 9.4.3)","VW 75209-1:2015-01 (p. 9.3.4)","VW 75209-1:2021-12 (p. 9.4.3)","VW 75209-2:2015-01 (p. 9.3.4)","VW 75209-2:2021-12 (p. 9.4.2)","VW 75210-1:2023-06 (p. 9.4.3)","VW 75210-1:2024-08 (p. 9.4.3)","VW 75210-2:2023-06 (p. 9.4.3)","MBN LV 112-1:2016-03 (p. 9.3.4)","MBN 50112-1:2023-06 (p. 12.3.5)","MBN LV 112-2:2012-01 (p. 8.4.5)","MBN 50112-2:2023-05 (p. 12.4.5)","MBN 50216-1:2023-07 (p. 12.4.5)","MBN LV 212-1:2017-08 (p. 9.3.4)","MBN 50212-1:2023-04 (p. 12.4.4)","MBN LV 216-2:2017-07 (p. 9.3.4)","MBN 50112-4:2024-06 (p. 12.3.6)","GS 95007-1-1:2013-05 (p. 9.3.4)","GS 95007-1-2:2013-05 (p. 9.3.4)","GS 95007-3-1:2015-08 (p. 9.3.4)","GS 95007-3-2:2015-09 (p. 9.3.4)","GS 95007-6-1:2016-03 (p. 9.3.4)","GS 95007-6-2:2017-04 (p. 9.3.4)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Siła zginania kabla / Bending force of the cable\nZakres:\nMaszyna wytrzymałościowa do 20 kN\nTensile machine up to 20 kN LV 112-1:2013-04 (p. 9.3.4) | LV 112-1:2014-04 (p. 9.3.4) | LV 112-2:2007-11 (p. 8.4.5) | LV 112-2:2013-04 (p. 9.3.4) | LV 212-1:2015-01 (p. 9.3.4) | LV 212-2:2015-01 (p. 9.3.4) | LV 216-1:2015-07 (p. 9.3.4) | LV 216-2:2017-02 (p. 9.3.4) | VW 60306-1:2018-09-01 (p. 9.3.3) | VW 60306-1:2021-10 (p. 9.4.3) | VW 60306-2:2013-04 (p. 9.3.4) | VW 60306-2:2021-11 (p. 9.4.3) | VW 60306-4:2021-12 (p. 9.4.3) | VW 75209-1:2015-01 (p. 9.3.4) | VW 75209-1:2021-12 (p. 9.4.3) | VW 75209-2:2015-01 (p. 9.3.4) | VW 75209-2:2021-12 (p. 9.4.2) | VW 75210-1:2023-06 (p. 9.4.3) | VW 75210-1:2024-08 (p. 9.4.3) | VW 75210-2:2023-06 (p. 9.4.3) | MBN LV 112-1:2016-03 (p. 9.3.4) | MBN 50112-1:2023-06 (p. 12.3.5) | MBN LV 112-2:2012-01 (p. 8.4.5) | MBN 50112-2:2023-05 (p. 12.4.5) | MBN 50216-1:2023-07 (p. 12.4.5) | MBN LV 212-1:2017-08 (p. 9.3.4) | MBN 50212-1:2023-04 (p. 12.4.4) | MBN LV 216-2:2017-07 (p. 9.3.4) | MBN 50112-4:2024-06 (p. 12.3.6) | GS 95007-1-1:2013-05 (p. 9.3.4) | GS 95007-1-2:2013-05 (p. 9.3.4) | GS 95007-3-1:2015-08 (p. 9.3.4) | GS 95007-3-2:2015-09 (p. 9.3.4) | GS 95007-6-1:2016-03 (p. 9.3.4) | GS 95007-6-2:2017-04 (p. 9.3.4) Kable / Cables Sila zginania kabla / Bending force of the cable\nZakres:\nMaszyna wytrzymalosciowa do 20 kN\nTensile machine up to 20 kN LV 112-1:2013-04 (p. 9.3.4) | LV 112-1:2014-04 (p. 9.3.4) | LV 112-2:2007-11 (p. 8.4.5) | LV 112-2:2013-04 (p. 9.3.4) | LV 212-1:2015-01 (p. 9.3.4) | LV 212-2:2015-01 (p. 9.3.4) | LV 216-1:2015-07 (p. 9.3.4) | LV 216-2:2017-02 (p. 9.3.4) | VW 60306-1:2018-09-01 (p. 9.3.3) | VW 60306-1:2021-10 (p. 9.4.3) | VW 60306-2:2013-04 (p. 9.3.4) | VW 60306-2:2021-11 (p. 9.4.3) | VW 60306-4:2021-12 (p. 9.4.3) | VW 75209-1:2015-01 (p. 9.3.4) | VW 75209-1:2021-12 (p. 9.4.3) | VW 75209-2:2015-01 (p. 9.3.4) | VW 75209-2:2021-12 (p. 9.4.2) | VW 75210-1:2023-06 (p. 9.4.3) | VW 75210-1:2024-08 (p. 9.4.3) | VW 75210-2:2023-06 (p. 9.4.3) | MBN LV 112-1:2016-03 (p. 9.3.4) | MBN 50112-1:2023-06 (p. 12.3.5) | MBN LV 112-2:2012-01 (p. 8.4.5) | MBN 50112-2:2023-05 (p. 12.4.5) | MBN 50216-1:2023-07 (p. 12.4.5) | MBN LV 212-1:2017-08 (p. 9.3.4) | MBN 50212-1:2023-04 (p. 12.4.4) | MBN LV 216-2:2017-07 (p. 9.3.4) | MBN 50112-4:2024-06 (p. 12.3.6) | GS 95007-1-1:2013-05 (p. 9.3.4) | GS 95007-1-2:2013-05 (p. 9.3.4) | GS 95007-3-1:2015-08 (p. 9.3.4) | GS 95007-3-2:2015-09 (p. 9.3.4) | GS 95007-6-1:2016-03 (p. 9.3.4) | GS 95007-6-2:2017-04 (p. 9.3.4)","categories":["other"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d981","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Wytrzymałość izolacji / powłoki na nacięcie / Notching resistance","parameters":[{"name":"Maszyna wytrzymałościowa","range":"do 20 kN"},{"name":"Tensile machine","range":"up to 20 kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość izolacji / powłoki na nacięcie / Notching resistance\nZakres:\nMaszyna wytrzymałościowa do 20 kN\nTensile machine up to 20 kN","reference":"LV 112-1:2013-04 (p. 9.3.5) | LV 112-1:2014-04 (p. 9.3.5) | LV 112-2:2007-11 (p. 8.4.6) | LV 112-2:2013-04 (p. 9.3.5) | LV 212-2:2015-01 (p. 9.3.5) | LV 216-1:2015-07 (p. 9.3.5) | LV 216-2:2017-02 (p. 9.3.5) | VW 60306-1:2018-09-01 (p. 9.3.4) | VW 60306-1:2021-10 (p. 9.4.4) | VW 60306-2:2013-04 (p. 9.3.5) | VW 60306-2:2021-11 (p. 9.4.4) | VW 60306-4:2021-12 (p. 9.4.4) | VW 75209-1:2015-01 (p. 9.3.5) | VW 75209-2:2015-01 (p. 9.3.5) | VW 75209-2:2021-12 (p. 9.4.3) | VW 75210-1:2023-06 (p. 9.4.4) | VW 75210-1:2024-08 (p. 9.4.4) | VW 75210-2:2023-06 (p. 9.4.4) | MBN LV 112-1:2016-03 (p. 9.3.5) | MBN 50112-1:2023-06 (p. 12.3.6) | MBN LV 112-2:2012-01 (p. 8.4.6) | MBN 50112-2:2023-05 (p. 12.4.6) | MBN 50216-1:2023-07 (p. 12.4.6) | MBN LV 216-2:2017-07 (p. 9.3.5) | MBN 50112-4:2024-06 (p. 12.3.7) | GS 95007-1-1:2013-05 (p. 9.3.5) | GS 95007-1-2:2013-05 (p. 9.3.5) | GS 95007-3-2:2015-09 (p. 9.3.5) | GS 95007-6-1:2016-03 (p. 9.3.5) | GS 95007-6-2:2017-04 (p. 9.3.5)","norm_bases":["LV 112-1:2013-04 (p. 9.3.5)","LV 112-1:2014-04 (p. 9.3.5)","LV 112-2:2007-11 (p. 8.4.6)","LV 112-2:2013-04 (p. 9.3.5)","LV 212-2:2015-01 (p. 9.3.5)","LV 216-1:2015-07 (p. 9.3.5)","LV 216-2:2017-02 (p. 9.3.5)","VW 60306-1:2018-09-01 (p. 9.3.4)","VW 60306-1:2021-10 (p. 9.4.4)","VW 60306-2:2013-04 (p. 9.3.5)","VW 60306-2:2021-11 (p. 9.4.4)","VW 60306-4:2021-12 (p. 9.4.4)","VW 75209-1:2015-01 (p. 9.3.5)","VW 75209-2:2015-01 (p. 9.3.5)","VW 75209-2:2021-12 (p. 9.4.3)","VW 75210-1:2023-06 (p. 9.4.4)","VW 75210-1:2024-08 (p. 9.4.4)","VW 75210-2:2023-06 (p. 9.4.4)","MBN LV 112-1:2016-03 (p. 9.3.5)","MBN 50112-1:2023-06 (p. 12.3.6)","MBN LV 112-2:2012-01 (p. 8.4.6)","MBN 50112-2:2023-05 (p. 12.4.6)","MBN 50216-1:2023-07 (p. 12.4.6)","MBN LV 216-2:2017-07 (p. 9.3.5)","MBN 50112-4:2024-06 (p. 12.3.7)","GS 95007-1-1:2013-05 (p. 9.3.5)","GS 95007-1-2:2013-05 (p. 9.3.5)","GS 95007-3-2:2015-09 (p. 9.3.5)","GS 95007-6-1:2016-03 (p. 9.3.5)","GS 95007-6-2:2017-04 (p. 9.3.5)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Wytrzymałość izolacji / powłoki na nacięcie / Notching resistance\nZakres:\nMaszyna wytrzymałościowa do 20 kN\nTensile machine up to 20 kN LV 112-1:2013-04 (p. 9.3.5) | LV 112-1:2014-04 (p. 9.3.5) | LV 112-2:2007-11 (p. 8.4.6) | LV 112-2:2013-04 (p. 9.3.5) | LV 212-2:2015-01 (p. 9.3.5) | LV 216-1:2015-07 (p. 9.3.5) | LV 216-2:2017-02 (p. 9.3.5) | VW 60306-1:2018-09-01 (p. 9.3.4) | VW 60306-1:2021-10 (p. 9.4.4) | VW 60306-2:2013-04 (p. 9.3.5) | VW 60306-2:2021-11 (p. 9.4.4) | VW 60306-4:2021-12 (p. 9.4.4) | VW 75209-1:2015-01 (p. 9.3.5) | VW 75209-2:2015-01 (p. 9.3.5) | VW 75209-2:2021-12 (p. 9.4.3) | VW 75210-1:2023-06 (p. 9.4.4) | VW 75210-1:2024-08 (p. 9.4.4) | VW 75210-2:2023-06 (p. 9.4.4) | MBN LV 112-1:2016-03 (p. 9.3.5) | MBN 50112-1:2023-06 (p. 12.3.6) | MBN LV 112-2:2012-01 (p. 8.4.6) | MBN 50112-2:2023-05 (p. 12.4.6) | MBN 50216-1:2023-07 (p. 12.4.6) | MBN LV 216-2:2017-07 (p. 9.3.5) | MBN 50112-4:2024-06 (p. 12.3.7) | GS 95007-1-1:2013-05 (p. 9.3.5) | GS 95007-1-2:2013-05 (p. 9.3.5) | GS 95007-3-2:2015-09 (p. 9.3.5) | GS 95007-6-1:2016-03 (p. 9.3.5) | GS 95007-6-2:2017-04 (p. 9.3.5) Kable / Cables Wytrzymalosc izolacji / powloki na naciecie / Notching resistance\nZakres:\nMaszyna wytrzymalosciowa do 20 kN\nTensile machine up to 20 kN LV 112-1:2013-04 (p. 9.3.5) | LV 112-1:2014-04 (p. 9.3.5) | LV 112-2:2007-11 (p. 8.4.6) | LV 112-2:2013-04 (p. 9.3.5) | LV 212-2:2015-01 (p. 9.3.5) | LV 216-1:2015-07 (p. 9.3.5) | LV 216-2:2017-02 (p. 9.3.5) | VW 60306-1:2018-09-01 (p. 9.3.4) | VW 60306-1:2021-10 (p. 9.4.4) | VW 60306-2:2013-04 (p. 9.3.5) | VW 60306-2:2021-11 (p. 9.4.4) | VW 60306-4:2021-12 (p. 9.4.4) | VW 75209-1:2015-01 (p. 9.3.5) | VW 75209-2:2015-01 (p. 9.3.5) | VW 75209-2:2021-12 (p. 9.4.3) | VW 75210-1:2023-06 (p. 9.4.4) | VW 75210-1:2024-08 (p. 9.4.4) | VW 75210-2:2023-06 (p. 9.4.4) | MBN LV 112-1:2016-03 (p. 9.3.5) | MBN 50112-1:2023-06 (p. 12.3.6) | MBN LV 112-2:2012-01 (p. 8.4.6) | MBN 50112-2:2023-05 (p. 12.4.6) | MBN 50216-1:2023-07 (p. 12.4.6) | MBN LV 216-2:2017-07 (p. 9.3.5) | MBN 50112-4:2024-06 (p. 12.3.7) | GS 95007-1-1:2013-05 (p. 9.3.5) | GS 95007-1-2:2013-05 (p. 9.3.5) | GS 95007-3-2:2015-09 (p. 9.3.5) | GS 95007-6-1:2016-03 (p. 9.3.5) | GS 95007-6-2:2017-04 (p. 9.3.5)","categories":["construction"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d982","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Stabilność termiczna w stanie nawinięcia / Thermal stability in wound state","parameters":[{"name":"Piec","range":"do 200 °C (± 2 °C)"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Zakres","range":"0,5 kV do 6 kV D.C."},{"name":"Aging Oven","range":"up to 200 °C (± 2 °C)"},{"name":"Range","range":"0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Range","range":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"computed":[],"activity":"Stabilność termiczna w stanie nawinięcia / Thermal stability in wound state\nZakres:\nPiec do 200 °C (± 2 °C)\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging Oven up to 200 °C (± 2 °C)\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C.","reference":"LV 112-1:2013-04 (p. 9.6.5) | LV 112-1:2014-04 (p. 9.6.5) | LV 112-2:2007-11 (p. 8.7.4) | LV 112-2:2013-04 (p. 9.6.5) | LV 216-1:2015-07 (p. 9.6.5) | VW 60306-1:2018-09-01 (p. 9.6.5) | VW 60306-1:2021-10 (p. 9.7.5) | VW 60306-2:2013-04 (p. 9.6.5) | VW 60306-2:2021-11 (p. 9.7.5) | VW 60306-4:2021-12 (p. 9.7.5) | VW 75210-1:2023-06 (p. 9.7.5) | VW 75210-1:2024-08 (p. 9.7.5) | MBN LV 112-1:2016-03 (p. 9.6.5) | MBN 50112-1:2023-06 (p. 12.6.5) | MBN LV 112-2:2012-01 (p. 8.7.4) | MBN 50112-2:2023-05 (p. 12.7.4) | MBN 50216-1:2023-07 (p. 12.7.4.1) | MBN 50112-4:2024-06 (p. 12.6.5) | GS 95007-1-1:2013-05 (p. 9.6.5) | GS 95007-1-2:2013-05 (p. 9.6.5) | GS 95007-6-1:2016-03 (p. 9.6.5)","norm_bases":["LV 112-1:2013-04 (p. 9.6.5)","LV 112-1:2014-04 (p. 9.6.5)","LV 112-2:2007-11 (p. 8.7.4)","LV 112-2:2013-04 (p. 9.6.5)","LV 216-1:2015-07 (p. 9.6.5)","VW 60306-1:2018-09-01 (p. 9.6.5)","VW 60306-1:2021-10 (p. 9.7.5)","VW 60306-2:2013-04 (p. 9.6.5)","VW 60306-2:2021-11 (p. 9.7.5)","VW 60306-4:2021-12 (p. 9.7.5)","VW 75210-1:2023-06 (p. 9.7.5)","VW 75210-1:2024-08 (p. 9.7.5)","MBN LV 112-1:2016-03 (p. 9.6.5)","MBN 50112-1:2023-06 (p. 12.6.5)","MBN LV 112-2:2012-01 (p. 8.7.4)","MBN 50112-2:2023-05 (p. 12.7.4)","MBN 50216-1:2023-07 (p. 12.7.4.1)","MBN 50112-4:2024-06 (p. 12.6.5)","GS 95007-1-1:2013-05 (p. 9.6.5)","GS 95007-1-2:2013-05 (p. 9.6.5)","GS 95007-6-1:2016-03 (p. 9.6.5)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Stabilność termiczna w stanie nawinięcia / Thermal stability in wound state\nZakres:\nPiec do 200 °C (± 2 °C)\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging Oven up to 200 °C (± 2 °C)\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. LV 112-1:2013-04 (p. 9.6.5) | LV 112-1:2014-04 (p. 9.6.5) | LV 112-2:2007-11 (p. 8.7.4) | LV 112-2:2013-04 (p. 9.6.5) | LV 216-1:2015-07 (p. 9.6.5) | VW 60306-1:2018-09-01 (p. 9.6.5) | VW 60306-1:2021-10 (p. 9.7.5) | VW 60306-2:2013-04 (p. 9.6.5) | VW 60306-2:2021-11 (p. 9.7.5) | VW 60306-4:2021-12 (p. 9.7.5) | VW 75210-1:2023-06 (p. 9.7.5) | VW 75210-1:2024-08 (p. 9.7.5) | MBN LV 112-1:2016-03 (p. 9.6.5) | MBN 50112-1:2023-06 (p. 12.6.5) | MBN LV 112-2:2012-01 (p. 8.7.4) | MBN 50112-2:2023-05 (p. 12.7.4) | MBN 50216-1:2023-07 (p. 12.7.4.1) | MBN 50112-4:2024-06 (p. 12.6.5) | GS 95007-1-1:2013-05 (p. 9.6.5) | GS 95007-1-2:2013-05 (p. 9.6.5) | GS 95007-6-1:2016-03 (p. 9.6.5) Kable / Cables Stabilnosc termiczna w stanie nawiniecia / Thermal stability in wound state\nZakres:\nPiec do 200 °C (± 2 °C)\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging Oven up to 200 °C (± 2 °C)\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. LV 112-1:2013-04 (p. 9.6.5) | LV 112-1:2014-04 (p. 9.6.5) | LV 112-2:2007-11 (p. 8.7.4) | LV 112-2:2013-04 (p. 9.6.5) | LV 216-1:2015-07 (p. 9.6.5) | VW 60306-1:2018-09-01 (p. 9.6.5) | VW 60306-1:2021-10 (p. 9.7.5) | VW 60306-2:2013-04 (p. 9.6.5) | VW 60306-2:2021-11 (p. 9.7.5) | VW 60306-4:2021-12 (p. 9.7.5) | VW 75210-1:2023-06 (p. 9.7.5) | VW 75210-1:2024-08 (p. 9.7.5) | MBN LV 112-1:2016-03 (p. 9.6.5) | MBN 50112-1:2023-06 (p. 12.6.5) | MBN LV 112-2:2012-01 (p. 8.7.4) | MBN 50112-2:2023-05 (p. 12.7.4) | MBN 50216-1:2023-07 (p. 12.7.4.1) | MBN 50112-4:2024-06 (p. 12.6.5) | GS 95007-1-1:2013-05 (p. 9.6.5) | GS 95007-1-2:2013-05 (p. 9.6.5) | GS 95007-6-1:2016-03 (p. 9.6.5)","categories":["other"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d983","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Odporność kabla na ekstremalne przeciążenie cieplne / Extreme thermal overload","parameters":[{"name":"Piec","range":"do 200 °C (± 2 °C)"},{"name":"Komora klimatyczna","range":"-40 °C do 125 °C"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Zakres","range":"0,5 kV do 6 kV D.C."},{"name":"Aging Oven","range":"up to 200 °C (± 2 °C)"},{"name":"Climatic Chamber","range":"-40 °C to 125 °C"},{"name":"Range","range":"0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Range","range":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność kabla na ekstremalne przeciążenie cieplne / Extreme thermal overload\nZakres:\nPiec do 200 °C (± 2 °C)\nKomora klimatyczna -40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging Oven up to 200 °C (± 2 °C)\nClimatic Chamber -40 °C to 125 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C.","reference":"LV 112-1:2013-04 (p. 9.6.6.2) | LV 112-1:2014-04 (p. 9.6.6.2) | LV 112-2:2013-04 (p. 9.6.6.2) | LV 216-1:2015-07 (p. 9.6.6.2) | VW 60306-1:2018-09-01 (p. 9.6.6.2) | VW 60306-1:2021-10 (p. 9.7.6.2) | VW 60306-2:2013-04 (p. 9.6.6.2) | VW 60306-2:2021-11 (p. 9.7.6.2) | VW 60306-4:2021-12 (p. 9.7.6.2) | VW 75210-1:2024-08 (p. 9.7.6, 9.7.6.2) | MBN LV 112-1:2016-03 (p. 9.6.6.2) | MBN 50112-1:2023-06 (p. 12.6.6.2) | MBN 50216-1:2023-07 (p. 12.7.5.3) | MBN 50112-4:2024-06 (p. 12.6.6) | GS 95007-1-1:2013-05 (p. 9.6.6.2) | GS 95007-1-2:2013-05 (p. 9.6.6.2) | GS 95007-6-1:2016-03 (p. 9.6.6.2)","norm_bases":["LV 112-1:2013-04 (p. 9.6.6.2)","LV 112-1:2014-04 (p. 9.6.6.2)","LV 112-2:2013-04 (p. 9.6.6.2)","LV 216-1:2015-07 (p. 9.6.6.2)","VW 60306-1:2018-09-01 (p. 9.6.6.2)","VW 60306-1:2021-10 (p. 9.7.6.2)","VW 60306-2:2013-04 (p. 9.6.6.2)","VW 60306-2:2021-11 (p. 9.7.6.2)","VW 60306-4:2021-12 (p. 9.7.6.2)","VW 75210-1:2024-08 (p. 9.7.6, 9.7.6.2)","MBN LV 112-1:2016-03 (p. 9.6.6.2)","MBN 50112-1:2023-06 (p. 12.6.6.2)","MBN 50216-1:2023-07 (p. 12.7.5.3)","MBN 50112-4:2024-06 (p. 12.6.6)","GS 95007-1-1:2013-05 (p. 9.6.6.2)","GS 95007-1-2:2013-05 (p. 9.6.6.2)","GS 95007-6-1:2016-03 (p. 9.6.6.2)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Odporność kabla na ekstremalne przeciążenie cieplne / Extreme thermal overload\nZakres:\nPiec do 200 °C (± 2 °C)\nKomora klimatyczna -40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging Oven up to 200 °C (± 2 °C)\nClimatic Chamber -40 °C to 125 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. LV 112-1:2013-04 (p. 9.6.6.2) | LV 112-1:2014-04 (p. 9.6.6.2) | LV 112-2:2013-04 (p. 9.6.6.2) | LV 216-1:2015-07 (p. 9.6.6.2) | VW 60306-1:2018-09-01 (p. 9.6.6.2) | VW 60306-1:2021-10 (p. 9.7.6.2) | VW 60306-2:2013-04 (p. 9.6.6.2) | VW 60306-2:2021-11 (p. 9.7.6.2) | VW 60306-4:2021-12 (p. 9.7.6.2) | VW 75210-1:2024-08 (p. 9.7.6, 9.7.6.2) | MBN LV 112-1:2016-03 (p. 9.6.6.2) | MBN 50112-1:2023-06 (p. 12.6.6.2) | MBN 50216-1:2023-07 (p. 12.7.5.3) | MBN 50112-4:2024-06 (p. 12.6.6) | GS 95007-1-1:2013-05 (p. 9.6.6.2) | GS 95007-1-2:2013-05 (p. 9.6.6.2) | GS 95007-6-1:2016-03 (p. 9.6.6.2) Kable / Cables Odpornosc kabla na ekstremalne przeciazenie cieplne / Extreme thermal overload\nZakres:\nPiec do 200 °C (± 2 °C)\nKomora klimatyczna -40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging Oven up to 200 °C (± 2 °C)\nClimatic Chamber -40 °C to 125 °C\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. LV 112-1:2013-04 (p. 9.6.6.2) | LV 112-1:2014-04 (p. 9.6.6.2) | LV 112-2:2013-04 (p. 9.6.6.2) | LV 216-1:2015-07 (p. 9.6.6.2) | VW 60306-1:2018-09-01 (p. 9.6.6.2) | VW 60306-1:2021-10 (p. 9.7.6.2) | VW 60306-2:2013-04 (p. 9.6.6.2) | VW 60306-2:2021-11 (p. 9.7.6.2) | VW 60306-4:2021-12 (p. 9.7.6.2) | VW 75210-1:2024-08 (p. 9.7.6, 9.7.6.2) | MBN LV 112-1:2016-03 (p. 9.6.6.2) | MBN 50112-1:2023-06 (p. 12.6.6.2) | MBN 50216-1:2023-07 (p. 12.7.5.3) | MBN 50112-4:2024-06 (p. 12.6.6) | GS 95007-1-1:2013-05 (p. 9.6.6.2) | GS 95007-1-2:2013-05 (p. 9.6.6.2) | GS 95007-6-1:2016-03 (p. 9.6.6.2)","categories":["other"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d984","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Minimalny dopuszczalny promień gięcia dla statycznego prowadzenia kabla / Minimum permissible bending radius for static routing","parameters":[{"name":"Piec","range":"do 200 °C (± 2 °C)"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Zakres","range":"0,5 kV do 6 kV D.C."},{"name":"Aging Oven","range":"up to 200 °C (± 2 °C)"},{"name":"Range","range":"0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Range","range":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"computed":[],"activity":"Minimalny dopuszczalny promień gięcia dla statycznego prowadzenia kabla / Minimum permissible bending radius for static routing\nZakres:\nPiec do 200 °C (± 2 °C)\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging Oven up to 200 °C (± 2 °C)\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C.","reference":"LV 112-1:2013-04 (p. 9.6.8.4) | LV 112-2:2013-04 (p. 9.6.8.4) | LV 212-1:2015-01 (p. 9.6.7.4) | LV 212-2:2015-01 (p. 9.6.7.4) | LV 216-1:2015-07 (p. 9.6.8.4) | VW 60306-1:2018-09-01 (p. 9.6.8.2) | VW 60306-1:2021-10 (p. 9.7.8.3) | VW 60306-2:2013-04 (p. 9.6.8.4) | VW 60306-2:2021-11 (p. 9.7.8.3) | VW 60306-4:2021-12 (p. 9.7.8.3) | VW 75209-1:2015-01 (p. 9.6.7.4) | VW 75209-1:2021-12 (p. 9.7.6.3) | VW 75209-2:2015-01 (p. 9.6.7.4) | VW 75209-2:2021-12 (p. 9.7.6.3) | VW 75210-1:2023-06 (p. 9.7.8.2) | VW 75210-1:2024-08 (p. 9.7.7, 9.7.7.2; 9.7.8; 9.7.8.2) | MBN LV 112-1:2016-03 (p. 9.6.8.4) | MBN 50112-1:2023-06 (p. 12.6.8.5) | MBN 50212-1:2023-04 (p. 12.7.7.5) | MBN 50216-1:2023-07 (p. 12.7.7.5) | MBN 50112-4:2024-06 (p. 12.6.8.4) | MBN LV 212-1:2017-08 (p. 9.6.7.4) | GS 95007-1-1:2013-05 (p. 9.6.8.4) | GS 95007-1-2:2013-05 (p. 9.6.8.4) | GS 95007-3-1:2015-08 (p. 9.6.7.4) | GS 95007-3-2:2015-09 (p. 9.6.7.4) | GS 95007-6-1:2016-03 (p. 9.6.8.4)","norm_bases":["LV 112-1:2013-04 (p. 9.6.8.4)","LV 112-2:2013-04 (p. 9.6.8.4)","LV 212-1:2015-01 (p. 9.6.7.4)","LV 212-2:2015-01 (p. 9.6.7.4)","LV 216-1:2015-07 (p. 9.6.8.4)","VW 60306-1:2018-09-01 (p. 9.6.8.2)","VW 60306-1:2021-10 (p. 9.7.8.3)","VW 60306-2:2013-04 (p. 9.6.8.4)","VW 60306-2:2021-11 (p. 9.7.8.3)","VW 60306-4:2021-12 (p. 9.7.8.3)","VW 75209-1:2015-01 (p. 9.6.7.4)","VW 75209-1:2021-12 (p. 9.7.6.3)","VW 75209-2:2015-01 (p. 9.6.7.4)","VW 75209-2:2021-12 (p. 9.7.6.3)","VW 75210-1:2023-06 (p. 9.7.8.2)","VW 75210-1:2024-08 (p. 9.7.7, 9.7.7.2; 9.7.8; 9.7.8.2)","MBN LV 112-1:2016-03 (p. 9.6.8.4)","MBN 50112-1:2023-06 (p. 12.6.8.5)","MBN 50212-1:2023-04 (p. 12.7.7.5)","MBN 50216-1:2023-07 (p. 12.7.7.5)","MBN 50112-4:2024-06 (p. 12.6.8.4)","MBN LV 212-1:2017-08 (p. 9.6.7.4)","GS 95007-1-1:2013-05 (p. 9.6.8.4)","GS 95007-1-2:2013-05 (p. 9.6.8.4)","GS 95007-3-1:2015-08 (p. 9.6.7.4)","GS 95007-3-2:2015-09 (p. 9.6.7.4)","GS 95007-6-1:2016-03 (p. 9.6.8.4)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Minimalny dopuszczalny promień gięcia dla statycznego prowadzenia kabla / Minimum permissible bending radius for static routing\nZakres:\nPiec do 200 °C (± 2 °C)\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging Oven up to 200 °C (± 2 °C)\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. LV 112-1:2013-04 (p. 9.6.8.4) | LV 112-2:2013-04 (p. 9.6.8.4) | LV 212-1:2015-01 (p. 9.6.7.4) | LV 212-2:2015-01 (p. 9.6.7.4) | LV 216-1:2015-07 (p. 9.6.8.4) | VW 60306-1:2018-09-01 (p. 9.6.8.2) | VW 60306-1:2021-10 (p. 9.7.8.3) | VW 60306-2:2013-04 (p. 9.6.8.4) | VW 60306-2:2021-11 (p. 9.7.8.3) | VW 60306-4:2021-12 (p. 9.7.8.3) | VW 75209-1:2015-01 (p. 9.6.7.4) | VW 75209-1:2021-12 (p. 9.7.6.3) | VW 75209-2:2015-01 (p. 9.6.7.4) | VW 75209-2:2021-12 (p. 9.7.6.3) | VW 75210-1:2023-06 (p. 9.7.8.2) | VW 75210-1:2024-08 (p. 9.7.7, 9.7.7.2; 9.7.8; 9.7.8.2) | MBN LV 112-1:2016-03 (p. 9.6.8.4) | MBN 50112-1:2023-06 (p. 12.6.8.5) | MBN 50212-1:2023-04 (p. 12.7.7.5) | MBN 50216-1:2023-07 (p. 12.7.7.5) | MBN 50112-4:2024-06 (p. 12.6.8.4) | MBN LV 212-1:2017-08 (p. 9.6.7.4) | GS 95007-1-1:2013-05 (p. 9.6.8.4) | GS 95007-1-2:2013-05 (p. 9.6.8.4) | GS 95007-3-1:2015-08 (p. 9.6.7.4) | GS 95007-3-2:2015-09 (p. 9.6.7.4) | GS 95007-6-1:2016-03 (p. 9.6.8.4) Kable / Cables Minimalny dopuszczalny promien giecia dla statycznego prowadzenia kabla / Minimum permissible bending radius for static routing\nZakres:\nPiec do 200 °C (± 2 °C)\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nAging Oven up to 200 °C (± 2 °C)\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. LV 112-1:2013-04 (p. 9.6.8.4) | LV 112-2:2013-04 (p. 9.6.8.4) | LV 212-1:2015-01 (p. 9.6.7.4) | LV 212-2:2015-01 (p. 9.6.7.4) | LV 216-1:2015-07 (p. 9.6.8.4) | VW 60306-1:2018-09-01 (p. 9.6.8.2) | VW 60306-1:2021-10 (p. 9.7.8.3) | VW 60306-2:2013-04 (p. 9.6.8.4) | VW 60306-2:2021-11 (p. 9.7.8.3) | VW 60306-4:2021-12 (p. 9.7.8.3) | VW 75209-1:2015-01 (p. 9.6.7.4) | VW 75209-1:2021-12 (p. 9.7.6.3) | VW 75209-2:2015-01 (p. 9.6.7.4) | VW 75209-2:2021-12 (p. 9.7.6.3) | VW 75210-1:2023-06 (p. 9.7.8.2) | VW 75210-1:2024-08 (p. 9.7.7, 9.7.7.2; 9.7.8; 9.7.8.2) | MBN LV 112-1:2016-03 (p. 9.6.8.4) | MBN 50112-1:2023-06 (p. 12.6.8.5) | MBN 50212-1:2023-04 (p. 12.7.7.5) | MBN 50216-1:2023-07 (p. 12.7.7.5) | MBN 50112-4:2024-06 (p. 12.6.8.4) | MBN LV 212-1:2017-08 (p. 9.6.7.4) | GS 95007-1-1:2013-05 (p. 9.6.8.4) | GS 95007-1-2:2013-05 (p. 9.6.8.4) | GS 95007-3-1:2015-08 (p. 9.6.7.4) | GS 95007-3-2:2015-09 (p. 9.6.7.4) | GS 95007-6-1:2016-03 (p. 9.6.8.4)","categories":["other"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d985","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Odporność kabla na łamanie / Kink Test","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność kabla na łamanie / Kink Test","reference":"LV 112-1:2013-04 (p. 9.6.13) | LV 112-1:2014-04 (p. 9.6.13) | LV 112-2:2007-11 (p. 8.7.12) | LV 112-2:2013-04 (p. 9.6.13) | LV 216-1:2015-07 (p. 9.6.13) | VW 60306-1:2018-09-01 (p. 9.6.13) | VW 60306-1:2021-10 (p. 9.7.13) | VW 60306-2:2013-04 (p. 9.6.13) | VW 60306-2:2021-11 (p. 9.7.13) | VW 60306-4:2021-12 (p. 9.7.13) | VW 75210-1:2024-08 (p. 9.7.13) | MBN LV 112-1:2016-03 (p. 9.6.13) | MBN 50112-1:2023-06 (p. 12.6.13) | MBN LV 112-2:2012-01 (p. 8.7.12) | MBN 50112-2:2023-05 (p. 12.7.12) | MBN 50216-1:2023-07 (p. 12.7.12) | MBN 50112-4:2024-06 (p. 12.6.13) | GS 95007-1-1:2013-05 (p. 9.6.13) | GS 95007-1-2:2013-05 (p. 9.6.13) | GS 95007-6-1:2016-03 (p. 9.6.13)","norm_bases":["LV 112-1:2013-04 (p. 9.6.13)","LV 112-1:2014-04 (p. 9.6.13)","LV 112-2:2007-11 (p. 8.7.12)","LV 112-2:2013-04 (p. 9.6.13)","LV 216-1:2015-07 (p. 9.6.13)","VW 60306-1:2018-09-01 (p. 9.6.13)","VW 60306-1:2021-10 (p. 9.7.13)","VW 60306-2:2013-04 (p. 9.6.13)","VW 60306-2:2021-11 (p. 9.7.13)","VW 60306-4:2021-12 (p. 9.7.13)","VW 75210-1:2024-08 (p. 9.7.13)","MBN LV 112-1:2016-03 (p. 9.6.13)","MBN 50112-1:2023-06 (p. 12.6.13)","MBN LV 112-2:2012-01 (p. 8.7.12)","MBN 50112-2:2023-05 (p. 12.7.12)","MBN 50216-1:2023-07 (p. 12.7.12)","MBN 50112-4:2024-06 (p. 12.6.13)","GS 95007-1-1:2013-05 (p. 9.6.13)","GS 95007-1-2:2013-05 (p. 9.6.13)","GS 95007-6-1:2016-03 (p. 9.6.13)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Odporność kabla na łamanie / Kink Test LV 112-1:2013-04 (p. 9.6.13) | LV 112-1:2014-04 (p. 9.6.13) | LV 112-2:2007-11 (p. 8.7.12) | LV 112-2:2013-04 (p. 9.6.13) | LV 216-1:2015-07 (p. 9.6.13) | VW 60306-1:2018-09-01 (p. 9.6.13) | VW 60306-1:2021-10 (p. 9.7.13) | VW 60306-2:2013-04 (p. 9.6.13) | VW 60306-2:2021-11 (p. 9.7.13) | VW 60306-4:2021-12 (p. 9.7.13) | VW 75210-1:2024-08 (p. 9.7.13) | MBN LV 112-1:2016-03 (p. 9.6.13) | MBN 50112-1:2023-06 (p. 12.6.13) | MBN LV 112-2:2012-01 (p. 8.7.12) | MBN 50112-2:2023-05 (p. 12.7.12) | MBN 50216-1:2023-07 (p. 12.7.12) | MBN 50112-4:2024-06 (p. 12.6.13) | GS 95007-1-1:2013-05 (p. 9.6.13) | GS 95007-1-2:2013-05 (p. 9.6.13) | GS 95007-6-1:2016-03 (p. 9.6.13) Kable / Cables Odpornosc kabla na lamanie / Kink Test LV 112-1:2013-04 (p. 9.6.13) | LV 112-1:2014-04 (p. 9.6.13) | LV 112-2:2007-11 (p. 8.7.12) | LV 112-2:2013-04 (p. 9.6.13) | LV 216-1:2015-07 (p. 9.6.13) | VW 60306-1:2018-09-01 (p. 9.6.13) | VW 60306-1:2021-10 (p. 9.7.13) | VW 60306-2:2013-04 (p. 9.6.13) | VW 60306-2:2021-11 (p. 9.7.13) | VW 60306-4:2021-12 (p. 9.7.13) | VW 75210-1:2024-08 (p. 9.7.13) | MBN LV 112-1:2016-03 (p. 9.6.13) | MBN 50112-1:2023-06 (p. 12.6.13) | MBN LV 112-2:2012-01 (p. 8.7.12) | MBN 50112-2:2023-05 (p. 12.7.12) | MBN 50216-1:2023-07 (p. 12.7.12) | MBN 50112-4:2024-06 (p. 12.6.13) | GS 95007-1-1:2013-05 (p. 9.6.13) | GS 95007-1-2:2013-05 (p. 9.6.13) | GS 95007-6-1:2016-03 (p. 9.6.13)","categories":["other"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d986","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Stałe, wilgotne ciepło (hydroliza) / Damp heat, constant (hydrolysis test)","parameters":[{"name":"Komora klimatyczna","range":"-40 °C do 175 °C, (85 ±5) % RH"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Zakres","range":"0,5 kV do 6 kV D.C."},{"name":"Climatic Chamber","range":"-40 °C to 125 °C, (85 ± 5) % RH"},{"name":"Range","range":"0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"Range","range":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"computed":[],"activity":"Stałe, wilgotne ciepło (hydroliza) / Damp heat, constant (hydrolysis test)\nZakres:\nKomora klimatyczna -40 °C do 175 °C, (85 ±5) % RH\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nClimatic Chamber -40 °C to 125 °C, (85 ± 5) % RH\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C.","reference":"LV 112-1:2013-04 (p. 9.6.15) | LV 112-1:2014-04 (p. 9.6.15) | LV 112-2:2007-11 (p. 8.7.14) | LV 112-2:2013-04 (p. 9.6.15) | LV 212-1:2015-01 (p. 9.6.13) | LV 212-2:2015-01 (p. 9.6.13) | LV 216-1:2015-07 (p. 9.6.15) | VW 60306-1:2018-09-01 (p. 9.6.15) | VW 60306-1:2021-10 (p. 9.7.15) | VW 60306-2:2013-04 (p. 9.6.15) | VW 60306-2:2021-11 (p. 9.7.15) | VW 60306-4:2021-12 (p. 9.7.15) | VW 75209-1:2015-01 (p. 9.6.13) | VW 75209-1:2021-12 (p. 9.7.11) | VW 75209-2:2015-01 (p. 9.6.13) | VW 75209-2:2021-12 (p. 9.7.12) | VW 75210-1:2023-06 (p. 9.7.15) | VW 75210-1:2024-08 (p. 9.7.15) | VW 75210-2:2023-06 (p. 9.7.12) | MBN LV 112-1:2016-03 (p. 9.6.15) | MBN 50112-1:2023-06 (p. 12.6.15) | MBN LV 112-2:2012-01 (p. 8.7.14) | MBN 50112-2:2023-05 (p. 12.7.14) | MBN 50216-1:2023-07 (p. 12.7.14) | MBN LV 212-1:2017-08 (p. 9.6.13) | MBN 50112-4:2024-06 (p. 12.6.15) | MBN 50212-1:2023-04 (p. 12.7.13) | GS 95007-1-1:2013-05 (p. 9.6.15) | GS 95007-1-2:2013-05 (p. 9.6.15) | GS 95007-3-1:2015-08 (p. 9.6.13) | GS 95007-3-2:2015-09 (p. 9.6.13) | GS 95007-6-1:2016-03 (p. 9.6.15)","norm_bases":["LV 112-1:2013-04 (p. 9.6.15)","LV 112-1:2014-04 (p. 9.6.15)","LV 112-2:2007-11 (p. 8.7.14)","LV 112-2:2013-04 (p. 9.6.15)","LV 212-1:2015-01 (p. 9.6.13)","LV 212-2:2015-01 (p. 9.6.13)","LV 216-1:2015-07 (p. 9.6.15)","VW 60306-1:2018-09-01 (p. 9.6.15)","VW 60306-1:2021-10 (p. 9.7.15)","VW 60306-2:2013-04 (p. 9.6.15)","VW 60306-2:2021-11 (p. 9.7.15)","VW 60306-4:2021-12 (p. 9.7.15)","VW 75209-1:2015-01 (p. 9.6.13)","VW 75209-1:2021-12 (p. 9.7.11)","VW 75209-2:2015-01 (p. 9.6.13)","VW 75209-2:2021-12 (p. 9.7.12)","VW 75210-1:2023-06 (p. 9.7.15)","VW 75210-1:2024-08 (p. 9.7.15)","VW 75210-2:2023-06 (p. 9.7.12)","MBN LV 112-1:2016-03 (p. 9.6.15)","MBN 50112-1:2023-06 (p. 12.6.15)","MBN LV 112-2:2012-01 (p. 8.7.14)","MBN 50112-2:2023-05 (p. 12.7.14)","MBN 50216-1:2023-07 (p. 12.7.14)","MBN LV 212-1:2017-08 (p. 9.6.13)","MBN 50112-4:2024-06 (p. 12.6.15)","MBN 50212-1:2023-04 (p. 12.7.13)","GS 95007-1-1:2013-05 (p. 9.6.15)","GS 95007-1-2:2013-05 (p. 9.6.15)","GS 95007-3-1:2015-08 (p. 9.6.13)","GS 95007-3-2:2015-09 (p. 9.6.13)","GS 95007-6-1:2016-03 (p. 9.6.15)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Stałe, wilgotne ciepło (hydroliza) / Damp heat, constant (hydrolysis test)\nZakres:\nKomora klimatyczna -40 °C do 175 °C, (85 ±5) % RH\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nClimatic Chamber -40 °C to 125 °C, (85 ± 5) % RH\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. LV 112-1:2013-04 (p. 9.6.15) | LV 112-1:2014-04 (p. 9.6.15) | LV 112-2:2007-11 (p. 8.7.14) | LV 112-2:2013-04 (p. 9.6.15) | LV 212-1:2015-01 (p. 9.6.13) | LV 212-2:2015-01 (p. 9.6.13) | LV 216-1:2015-07 (p. 9.6.15) | VW 60306-1:2018-09-01 (p. 9.6.15) | VW 60306-1:2021-10 (p. 9.7.15) | VW 60306-2:2013-04 (p. 9.6.15) | VW 60306-2:2021-11 (p. 9.7.15) | VW 60306-4:2021-12 (p. 9.7.15) | VW 75209-1:2015-01 (p. 9.6.13) | VW 75209-1:2021-12 (p. 9.7.11) | VW 75209-2:2015-01 (p. 9.6.13) | VW 75209-2:2021-12 (p. 9.7.12) | VW 75210-1:2023-06 (p. 9.7.15) | VW 75210-1:2024-08 (p. 9.7.15) | VW 75210-2:2023-06 (p. 9.7.12) | MBN LV 112-1:2016-03 (p. 9.6.15) | MBN 50112-1:2023-06 (p. 12.6.15) | MBN LV 112-2:2012-01 (p. 8.7.14) | MBN 50112-2:2023-05 (p. 12.7.14) | MBN 50216-1:2023-07 (p. 12.7.14) | MBN LV 212-1:2017-08 (p. 9.6.13) | MBN 50112-4:2024-06 (p. 12.6.15) | MBN 50212-1:2023-04 (p. 12.7.13) | GS 95007-1-1:2013-05 (p. 9.6.15) | GS 95007-1-2:2013-05 (p. 9.6.15) | GS 95007-3-1:2015-08 (p. 9.6.13) | GS 95007-3-2:2015-09 (p. 9.6.13) | GS 95007-6-1:2016-03 (p. 9.6.15) Kable / Cables Stale, wilgotne cieplo (hydroliza) / Damp heat, constant (hydrolysis test)\nZakres:\nKomora klimatyczna -40 °C do 175 °C, (85 ±5) % RH\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\nZakres 0,5 kV do 6 kV D.C.\nClimatic Chamber -40 °C to 125 °C, (85 ± 5) % RH\nRange 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\nRange 0,5 kV to 6 kV D.C. LV 112-1:2013-04 (p. 9.6.15) | LV 112-1:2014-04 (p. 9.6.15) | LV 112-2:2007-11 (p. 8.7.14) | LV 112-2:2013-04 (p. 9.6.15) | LV 212-1:2015-01 (p. 9.6.13) | LV 212-2:2015-01 (p. 9.6.13) | LV 216-1:2015-07 (p. 9.6.15) | VW 60306-1:2018-09-01 (p. 9.6.15) | VW 60306-1:2021-10 (p. 9.7.15) | VW 60306-2:2013-04 (p. 9.6.15) | VW 60306-2:2021-11 (p. 9.7.15) | VW 60306-4:2021-12 (p. 9.7.15) | VW 75209-1:2015-01 (p. 9.6.13) | VW 75209-1:2021-12 (p. 9.7.11) | VW 75209-2:2015-01 (p. 9.6.13) | VW 75209-2:2021-12 (p. 9.7.12) | VW 75210-1:2023-06 (p. 9.7.15) | VW 75210-1:2024-08 (p. 9.7.15) | VW 75210-2:2023-06 (p. 9.7.12) | MBN LV 112-1:2016-03 (p. 9.6.15) | MBN 50112-1:2023-06 (p. 12.6.15) | MBN LV 112-2:2012-01 (p. 8.7.14) | MBN 50112-2:2023-05 (p. 12.7.14) | MBN 50216-1:2023-07 (p. 12.7.14) | MBN LV 212-1:2017-08 (p. 9.6.13) | MBN 50112-4:2024-06 (p. 12.6.15) | MBN 50212-1:2023-04 (p. 12.7.13) | GS 95007-1-1:2013-05 (p. 9.6.15) | GS 95007-1-2:2013-05 (p. 9.6.15) | GS 95007-3-1:2015-08 (p. 9.6.13) | GS 95007-3-2:2015-09 (p. 9.6.13) | GS 95007-6-1:2016-03 (p. 9.6.15)","categories":["other"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d987","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Odporność kabla na chemikalia i taśmy / Resistance to chemicals and tapes","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność kabla na chemikalia i taśmy / Resistance to chemicals and tapes","reference":"LV 112-1:2013-04 (p. 9.8.2) | LV 112-1:2014-04 (p. 9.8.2) | LV 112-2:2007-11 (p. 8.9.2) | LV 112-2:2013-04 (p. 9.8.2) | LV 212-1:2015-01 (p. 9.8.2) | LV 212-2:2015-01 (p. 9.8.2) | LV 216-1:2015-07 (p. 9.8.2) | LV 216-2:2017-02 (p. 9.8.2) | VW 60306-1:2018-09-01 (p. 9.8.2) | VW 60306-1:2021-10 (p. 9.9) | VW 60306-2:2013-04 (p. 9.8.2) | VW 60306-2:2021-11 (p. 9.9) | VW 75209-1:2015-01 (p. 9.8.2) | VW 75209-2:2015-01 (p. 9.8.2) | VW 75209-2:2021-12 (p. 9.9) | VW 75210-1:2023-06 (p. 9.9) | VW 75210-1:2024-08 (p. 9.9) | VW 75210-2:2023-06 (p. 9.9) | MBN LV 112-1:2016-03 (p. 9.8.2) | MBN 50112-1:2023-06 (p. 12.8.3) | MBN LV 112-2:2012-01 (p. 8.9.2) | MBN 50112-2:2023-05 (p. 12.9.2) | MBN 50216-1:2023-07 (p. 12.9.2) | MBN LV 212-1:2017-08 (p. 9.8.2) | MBN 50212-1:2023-04 (p. 12.9.3) | MBN LV 216-2:2017-07 (p. 9.8.2) | MBN 50112-4:2024-06 (p. 12.8.3) | GS 95007-1-1:2013-05 (p. 9.8.2) | GS 95007-1-2:2013-05 (p. 9.8.2) | GS 95007-3-1:2015-08 (p. 9.8.2) | GS 95007-3-2:2015-09 (p. 9.8.2) | GS 95007-6-1:2016-03 (p. 9.8.2) | GS 95007-6-2:2017-04 (p. 9.8.2)","norm_bases":["LV 112-1:2013-04 (p. 9.8.2)","LV 112-1:2014-04 (p. 9.8.2)","LV 112-2:2007-11 (p. 8.9.2)","LV 112-2:2013-04 (p. 9.8.2)","LV 212-1:2015-01 (p. 9.8.2)","LV 212-2:2015-01 (p. 9.8.2)","LV 216-1:2015-07 (p. 9.8.2)","LV 216-2:2017-02 (p. 9.8.2)","VW 60306-1:2018-09-01 (p. 9.8.2)","VW 60306-1:2021-10 (p. 9.9)","VW 60306-2:2013-04 (p. 9.8.2)","VW 60306-2:2021-11 (p. 9.9)","VW 75209-1:2015-01 (p. 9.8.2)","VW 75209-2:2015-01 (p. 9.8.2)","VW 75209-2:2021-12 (p. 9.9)","VW 75210-1:2023-06 (p. 9.9)","VW 75210-1:2024-08 (p. 9.9)","VW 75210-2:2023-06 (p. 9.9)","MBN LV 112-1:2016-03 (p. 9.8.2)","MBN 50112-1:2023-06 (p. 12.8.3)","MBN LV 112-2:2012-01 (p. 8.9.2)","MBN 50112-2:2023-05 (p. 12.9.2)","MBN 50216-1:2023-07 (p. 12.9.2)","MBN LV 212-1:2017-08 (p. 9.8.2)","MBN 50212-1:2023-04 (p. 12.9.3)","MBN LV 216-2:2017-07 (p. 9.8.2)","MBN 50112-4:2024-06 (p. 12.8.3)","GS 95007-1-1:2013-05 (p. 9.8.2)","GS 95007-1-2:2013-05 (p. 9.8.2)","GS 95007-3-1:2015-08 (p. 9.8.2)","GS 95007-3-2:2015-09 (p. 9.8.2)","GS 95007-6-1:2016-03 (p. 9.8.2)","GS 95007-6-2:2017-04 (p. 9.8.2)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Odporność kabla na chemikalia i taśmy / Resistance to chemicals and tapes LV 112-1:2013-04 (p. 9.8.2) | LV 112-1:2014-04 (p. 9.8.2) | LV 112-2:2007-11 (p. 8.9.2) | LV 112-2:2013-04 (p. 9.8.2) | LV 212-1:2015-01 (p. 9.8.2) | LV 212-2:2015-01 (p. 9.8.2) | LV 216-1:2015-07 (p. 9.8.2) | LV 216-2:2017-02 (p. 9.8.2) | VW 60306-1:2018-09-01 (p. 9.8.2) | VW 60306-1:2021-10 (p. 9.9) | VW 60306-2:2013-04 (p. 9.8.2) | VW 60306-2:2021-11 (p. 9.9) | VW 75209-1:2015-01 (p. 9.8.2) | VW 75209-2:2015-01 (p. 9.8.2) | VW 75209-2:2021-12 (p. 9.9) | VW 75210-1:2023-06 (p. 9.9) | VW 75210-1:2024-08 (p. 9.9) | VW 75210-2:2023-06 (p. 9.9) | MBN LV 112-1:2016-03 (p. 9.8.2) | MBN 50112-1:2023-06 (p. 12.8.3) | MBN LV 112-2:2012-01 (p. 8.9.2) | MBN 50112-2:2023-05 (p. 12.9.2) | MBN 50216-1:2023-07 (p. 12.9.2) | MBN LV 212-1:2017-08 (p. 9.8.2) | MBN 50212-1:2023-04 (p. 12.9.3) | MBN LV 216-2:2017-07 (p. 9.8.2) | MBN 50112-4:2024-06 (p. 12.8.3) | GS 95007-1-1:2013-05 (p. 9.8.2) | GS 95007-1-2:2013-05 (p. 9.8.2) | GS 95007-3-1:2015-08 (p. 9.8.2) | GS 95007-3-2:2015-09 (p. 9.8.2) | GS 95007-6-1:2016-03 (p. 9.8.2) | GS 95007-6-2:2017-04 (p. 9.8.2) Kable / Cables Odpornosc kabla na chemikalia i tasmy / Resistance to chemicals and tapes LV 112-1:2013-04 (p. 9.8.2) | LV 112-1:2014-04 (p. 9.8.2) | LV 112-2:2007-11 (p. 8.9.2) | LV 112-2:2013-04 (p. 9.8.2) | LV 212-1:2015-01 (p. 9.8.2) | LV 212-2:2015-01 (p. 9.8.2) | LV 216-1:2015-07 (p. 9.8.2) | LV 216-2:2017-02 (p. 9.8.2) | VW 60306-1:2018-09-01 (p. 9.8.2) | VW 60306-1:2021-10 (p. 9.9) | VW 60306-2:2013-04 (p. 9.8.2) | VW 60306-2:2021-11 (p. 9.9) | VW 75209-1:2015-01 (p. 9.8.2) | VW 75209-2:2015-01 (p. 9.8.2) | VW 75209-2:2021-12 (p. 9.9) | VW 75210-1:2023-06 (p. 9.9) | VW 75210-1:2024-08 (p. 9.9) | VW 75210-2:2023-06 (p. 9.9) | MBN LV 112-1:2016-03 (p. 9.8.2) | MBN 50112-1:2023-06 (p. 12.8.3) | MBN LV 112-2:2012-01 (p. 8.9.2) | MBN 50112-2:2023-05 (p. 12.9.2) | MBN 50216-1:2023-07 (p. 12.9.2) | MBN LV 212-1:2017-08 (p. 9.8.2) | MBN 50212-1:2023-04 (p. 12.9.3) | MBN LV 216-2:2017-07 (p. 9.8.2) | MBN 50112-4:2024-06 (p. 12.8.3) | GS 95007-1-1:2013-05 (p. 9.8.2) | GS 95007-1-2:2013-05 (p. 9.8.2) | GS 95007-3-1:2015-08 (p. 9.8.2) | GS 95007-3-2:2015-09 (p. 9.8.2) | GS 95007-6-1:2016-03 (p. 9.8.2) | GS 95007-6-2:2017-04 (p. 9.8.2)","categories":["other"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d988","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Obrazowanie widma / Spectrum imaging","parameters":[],"technique":"Metoda spektroskopii w podczerwieni (FTIR) / Infrared spectroscopy (FTIR) method","techniques":[],"computed":[],"activity":"Obrazowanie widma / Spectrum imaging\nMetoda spektroskopii w podczerwieni (FTIR) / Infrared spectroscopy (FTIR) method","reference":"LV 112-1:2013-04 (p. 9.2.6; 9.6.7.2; 9.6.8.2) | LV 112-1:2014-04 (p. 9.2.6; 9.6.7.2; 9.6.8.2) | LV 112-2:2007-11 (p. 8.3) | LV 112-2:2013-04 (p. 9.2; 9.6.7.2; 9.6.8.2) | LV 122:2015-05 (p. 11.2) | LV 122:2016-02 (p. 11.3) | LV 212-1:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | LV 212-2:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | LV 216-1:2015-07 (p. 9.2.6; 9.6.7.2; 9.6.8.2) | LV 216-2:2017-02 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | VW 60306-1:2021-10 (p. 9.3.7) | VW 60306-2:2013-04 (p. 9.2; 9.6.7.2; 9.6.8.2) | VW 60306-2:2021-11 (p. 9.3.7) | VW 60306-4:2021-12 (p. 9.3.7) | VW 75205:2019-11 (p. 11.2) | VW 75205:2023-05 (p. 11.2) | VW 75205:2024-04 (p. 11.3) | VW 75209-1:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | VW 75209-1:2021-12 (p. 9.3.7) | VW 75209-2:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | VW 75209-2:2021-12 (p. 9.3.6) | VW 75210-1:2023-06 (p. 9.3.4) | VW 75210-1:2024-08 (p. 9.3.4) | VW 75210-2:2023-06 (p. 9.3.4) | MBN LV 112-1:2016-03 (p. 9.2.6; 9.6.7.2; 9.6.8.2) | MBN 50112-1:2023-06 (p. 12.2.7; 12.6.7.3; 12.6.8.3) | MBN LV 112-2:2012-01 (p. 8.3) | MBN 50112-2:2023-05 (p. 12.3) | MBN 50216-1:2023-07 (p. 12.3.7; 12.7.6.3; 12.7.7.3) | MBN LV 122:2017-06 (p. 11.3) | MBN 50122:2023-07 (p. 13.3) | MBN LV 212-1:2017-08 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | MBN 50212-1:2023-04 (p. 12.3.7; 12.7.6.3; 12.7.7.3) | MBN LV 216-2:2017-07 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | MBN 50112-4:2024-06 (p. 12.2.7; 12.6.7.2; 12.6.8.2) | GS 95007-1-1:2013-05 (p. 9.2.6; 9.6.7.2; 9.6.8.2) | GS 95007-1-2:2013-05 (p. 9.2; 9.6.7.2; 9.6.8.2) | GS 95007-1-5:2015-07 (p. 11.2) | GS 95007-3-1:2015-08 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | GS 95007-3-2:2015-09 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | GS 95007-6-1:2016-03 (p. 9.2.6; 9.6.7.2; 9.6.8.2) | GS 95007-6-2:2017-04 (p. 9.2.6; 9.6.6.2; 9.6.7.2)","norm_bases":["LV 112-1:2013-04 (p. 9.2.6; 9.6.7.2; 9.6.8.2)","LV 112-1:2014-04 (p. 9.2.6; 9.6.7.2; 9.6.8.2)","LV 112-2:2007-11 (p. 8.3)","LV 112-2:2013-04 (p. 9.2; 9.6.7.2; 9.6.8.2)","LV 122:2015-05 (p. 11.2)","LV 122:2016-02 (p. 11.3)","LV 212-1:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2)","LV 212-2:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2)","LV 216-1:2015-07 (p. 9.2.6; 9.6.7.2; 9.6.8.2)","LV 216-2:2017-02 (p. 9.2.6; 9.6.6.2; 9.6.7.2)","VW 60306-1:2021-10 (p. 9.3.7)","VW 60306-2:2013-04 (p. 9.2; 9.6.7.2; 9.6.8.2)","VW 60306-2:2021-11 (p. 9.3.7)","VW 60306-4:2021-12 (p. 9.3.7)","VW 75205:2019-11 (p. 11.2)","VW 75205:2023-05 (p. 11.2)","VW 75205:2024-04 (p. 11.3)","VW 75209-1:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2)","VW 75209-1:2021-12 (p. 9.3.7)","VW 75209-2:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2)","VW 75209-2:2021-12 (p. 9.3.6)","VW 75210-1:2023-06 (p. 9.3.4)","VW 75210-1:2024-08 (p. 9.3.4)","VW 75210-2:2023-06 (p. 9.3.4)","MBN LV 112-1:2016-03 (p. 9.2.6; 9.6.7.2; 9.6.8.2)","MBN 50112-1:2023-06 (p. 12.2.7; 12.6.7.3; 12.6.8.3)","MBN LV 112-2:2012-01 (p. 8.3)","MBN 50112-2:2023-05 (p. 12.3)","MBN 50216-1:2023-07 (p. 12.3.7; 12.7.6.3; 12.7.7.3)","MBN LV 122:2017-06 (p. 11.3)","MBN 50122:2023-07 (p. 13.3)","MBN LV 212-1:2017-08 (p. 9.2.6; 9.6.6.2; 9.6.7.2)","MBN 50212-1:2023-04 (p. 12.3.7; 12.7.6.3; 12.7.7.3)","MBN LV 216-2:2017-07 (p. 9.2.6; 9.6.6.2; 9.6.7.2)","MBN 50112-4:2024-06 (p. 12.2.7; 12.6.7.2; 12.6.8.2)","GS 95007-1-1:2013-05 (p. 9.2.6; 9.6.7.2; 9.6.8.2)","GS 95007-1-2:2013-05 (p. 9.2; 9.6.7.2; 9.6.8.2)","GS 95007-1-5:2015-07 (p. 11.2)","GS 95007-3-1:2015-08 (p. 9.2.6; 9.6.6.2; 9.6.7.2)","GS 95007-3-2:2015-09 (p. 9.2.6; 9.6.6.2; 9.6.7.2)","GS 95007-6-1:2016-03 (p. 9.2.6; 9.6.7.2; 9.6.8.2)","GS 95007-6-2:2017-04 (p. 9.2.6; 9.6.6.2; 9.6.7.2)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Obrazowanie widma / Spectrum imaging\nMetoda spektroskopii w podczerwieni (FTIR) / Infrared spectroscopy (FTIR) method LV 112-1:2013-04 (p. 9.2.6; 9.6.7.2; 9.6.8.2) | LV 112-1:2014-04 (p. 9.2.6; 9.6.7.2; 9.6.8.2) | LV 112-2:2007-11 (p. 8.3) | LV 112-2:2013-04 (p. 9.2; 9.6.7.2; 9.6.8.2) | LV 122:2015-05 (p. 11.2) | LV 122:2016-02 (p. 11.3) | LV 212-1:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | LV 212-2:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | LV 216-1:2015-07 (p. 9.2.6; 9.6.7.2; 9.6.8.2) | LV 216-2:2017-02 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | VW 60306-1:2021-10 (p. 9.3.7) | VW 60306-2:2013-04 (p. 9.2; 9.6.7.2; 9.6.8.2) | VW 60306-2:2021-11 (p. 9.3.7) | VW 60306-4:2021-12 (p. 9.3.7) | VW 75205:2019-11 (p. 11.2) | VW 75205:2023-05 (p. 11.2) | VW 75205:2024-04 (p. 11.3) | VW 75209-1:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | VW 75209-1:2021-12 (p. 9.3.7) | VW 75209-2:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | VW 75209-2:2021-12 (p. 9.3.6) | VW 75210-1:2023-06 (p. 9.3.4) | VW 75210-1:2024-08 (p. 9.3.4) | VW 75210-2:2023-06 (p. 9.3.4) | MBN LV 112-1:2016-03 (p. 9.2.6; 9.6.7.2; 9.6.8.2) | MBN 50112-1:2023-06 (p. 12.2.7; 12.6.7.3; 12.6.8.3) | MBN LV 112-2:2012-01 (p. 8.3) | MBN 50112-2:2023-05 (p. 12.3) | MBN 50216-1:2023-07 (p. 12.3.7; 12.7.6.3; 12.7.7.3) | MBN LV 122:2017-06 (p. 11.3) | MBN 50122:2023-07 (p. 13.3) | MBN LV 212-1:2017-08 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | MBN 50212-1:2023-04 (p. 12.3.7; 12.7.6.3; 12.7.7.3) | MBN LV 216-2:2017-07 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | MBN 50112-4:2024-06 (p. 12.2.7; 12.6.7.2; 12.6.8.2) | GS 95007-1-1:2013-05 (p. 9.2.6; 9.6.7.2; 9.6.8.2) | GS 95007-1-2:2013-05 (p. 9.2; 9.6.7.2; 9.6.8.2) | GS 95007-1-5:2015-07 (p. 11.2) | GS 95007-3-1:2015-08 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | GS 95007-3-2:2015-09 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | GS 95007-6-1:2016-03 (p. 9.2.6; 9.6.7.2; 9.6.8.2) | GS 95007-6-2:2017-04 (p. 9.2.6; 9.6.6.2; 9.6.7.2) Kable / Cables Obrazowanie widma / Spectrum imaging\nMetoda spektroskopii w podczerwieni (FTIR) / Infrared spectroscopy (FTIR) method LV 112-1:2013-04 (p. 9.2.6; 9.6.7.2; 9.6.8.2) | LV 112-1:2014-04 (p. 9.2.6; 9.6.7.2; 9.6.8.2) | LV 112-2:2007-11 (p. 8.3) | LV 112-2:2013-04 (p. 9.2; 9.6.7.2; 9.6.8.2) | LV 122:2015-05 (p. 11.2) | LV 122:2016-02 (p. 11.3) | LV 212-1:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | LV 212-2:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | LV 216-1:2015-07 (p. 9.2.6; 9.6.7.2; 9.6.8.2) | LV 216-2:2017-02 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | VW 60306-1:2021-10 (p. 9.3.7) | VW 60306-2:2013-04 (p. 9.2; 9.6.7.2; 9.6.8.2) | VW 60306-2:2021-11 (p. 9.3.7) | VW 60306-4:2021-12 (p. 9.3.7) | VW 75205:2019-11 (p. 11.2) | VW 75205:2023-05 (p. 11.2) | VW 75205:2024-04 (p. 11.3) | VW 75209-1:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | VW 75209-1:2021-12 (p. 9.3.7) | VW 75209-2:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | VW 75209-2:2021-12 (p. 9.3.6) | VW 75210-1:2023-06 (p. 9.3.4) | VW 75210-1:2024-08 (p. 9.3.4) | VW 75210-2:2023-06 (p. 9.3.4) | MBN LV 112-1:2016-03 (p. 9.2.6; 9.6.7.2; 9.6.8.2) | MBN 50112-1:2023-06 (p. 12.2.7; 12.6.7.3; 12.6.8.3) | MBN LV 112-2:2012-01 (p. 8.3) | MBN 50112-2:2023-05 (p. 12.3) | MBN 50216-1:2023-07 (p. 12.3.7; 12.7.6.3; 12.7.7.3) | MBN LV 122:2017-06 (p. 11.3) | MBN 50122:2023-07 (p. 13.3) | MBN LV 212-1:2017-08 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | MBN 50212-1:2023-04 (p. 12.3.7; 12.7.6.3; 12.7.7.3) | MBN LV 216-2:2017-07 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | MBN 50112-4:2024-06 (p. 12.2.7; 12.6.7.2; 12.6.8.2) | GS 95007-1-1:2013-05 (p. 9.2.6; 9.6.7.2; 9.6.8.2) | GS 95007-1-2:2013-05 (p. 9.2; 9.6.7.2; 9.6.8.2) | GS 95007-1-5:2015-07 (p. 11.2) | GS 95007-3-1:2015-08 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | GS 95007-3-2:2015-09 (p. 9.2.6; 9.6.6.2; 9.6.7.2) | GS 95007-6-1:2016-03 (p. 9.2.6; 9.6.7.2; 9.6.8.2) | GS 95007-6-2:2017-04 (p. 9.2.6; 9.6.6.2; 9.6.7.2)","categories":["other"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d989","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Właściwości ślizgowe kabli / Sliding behavior of the cable","parameters":[{"name":"Odważniki","range":"5 N, 10 N"},{"name":"Średnice rolek","range":"20 mm, 30 mm, 40 mm, 50 mm, 60 mm, 80 mm"},{"name":"Weights","range":"5 N, 10 N"},{"name":"Roll diameters","range":"20 mm, 30 mm, 40 mm, 50 mm, 60 mm, 80 mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Właściwości ślizgowe kabli / Sliding behavior of the cable\nZakres:\nOdważniki 5 N, 10 N\nŚrednice rolek 20 mm, 30 mm, 40 mm, 50 mm, 60 mm, 80 mm\nWeights 5 N, 10 N\nRoll diameters 20 mm, 30 mm, 40 mm, 50 mm, 60 mm, 80 mm","reference":"LV 112-1:2013-04 (p. 9.3.3) | LV 112-1:2014-04 (p. 9.3.3) | LV 112-2:2007-11 (p. 8.4.4) | LV 112-2:2013-04 (p. 9.3.3) | LV 212-1:2015-01 (p. 9.3.3) | LV 212-2:2015-01 (p. 9.3.3) | LV 216-1:2015-07 (p. 9.3.3) | LV 216-2:2017-02 (p. 9.3.3) | VW 60306-2:2013-04 (p. 9.3.3) | VW 75209-1:2015-01 (p. 9.3.3) | VW 75209-2:2015-01 (p. 9.3.3) | MBN LV 112-1:2016-03 (p. 9.3.3) | MBN 50112-1:2023-06 (p. 12.3.4) | MBN LV 112-2:2012-01 (p. 8.4.4) | MBN 50112-2:2023-05 (p. 12.4.4) | MBN 50216-1:2023-07 (p. 12.4.4) | MBN LV 212-1:2017-08 (p. 9.3.3) | MBN 50212-1:2023-04 (p. 12.4.3) | MBN LV 216-2:2017-07 (p. 9.3.3) | MBN 50112-4:2024-06 (p. 12.3.5) | GS 95007-1-1:2013-05 (p. 9.3.3) | GS 95007-1-2:2013-05 (p. 9.3.3) | GS 95007-3-1:2015-08 (p. 9.3.3) | GS 95007-3-2:2015-09 (p. 9.3.3) | GS 95007-6-1:2016-03 (p. 9.3.3) | GS 95007-6-2:2017-04 (p. 9.3.3)","norm_bases":["LV 112-1:2013-04 (p. 9.3.3)","LV 112-1:2014-04 (p. 9.3.3)","LV 112-2:2007-11 (p. 8.4.4)","LV 112-2:2013-04 (p. 9.3.3)","LV 212-1:2015-01 (p. 9.3.3)","LV 212-2:2015-01 (p. 9.3.3)","LV 216-1:2015-07 (p. 9.3.3)","LV 216-2:2017-02 (p. 9.3.3)","VW 60306-2:2013-04 (p. 9.3.3)","VW 75209-1:2015-01 (p. 9.3.3)","VW 75209-2:2015-01 (p. 9.3.3)","MBN LV 112-1:2016-03 (p. 9.3.3)","MBN 50112-1:2023-06 (p. 12.3.4)","MBN LV 112-2:2012-01 (p. 8.4.4)","MBN 50112-2:2023-05 (p. 12.4.4)","MBN 50216-1:2023-07 (p. 12.4.4)","MBN LV 212-1:2017-08 (p. 9.3.3)","MBN 50212-1:2023-04 (p. 12.4.3)","MBN LV 216-2:2017-07 (p. 9.3.3)","MBN 50112-4:2024-06 (p. 12.3.5)","GS 95007-1-1:2013-05 (p. 9.3.3)","GS 95007-1-2:2013-05 (p. 9.3.3)","GS 95007-3-1:2015-08 (p. 9.3.3)","GS 95007-3-2:2015-09 (p. 9.3.3)","GS 95007-6-1:2016-03 (p. 9.3.3)","GS 95007-6-2:2017-04 (p. 9.3.3)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Właściwości ślizgowe kabli / Sliding behavior of the cable\nZakres:\nOdważniki 5 N, 10 N\nŚrednice rolek 20 mm, 30 mm, 40 mm, 50 mm, 60 mm, 80 mm\nWeights 5 N, 10 N\nRoll diameters 20 mm, 30 mm, 40 mm, 50 mm, 60 mm, 80 mm LV 112-1:2013-04 (p. 9.3.3) | LV 112-1:2014-04 (p. 9.3.3) | LV 112-2:2007-11 (p. 8.4.4) | LV 112-2:2013-04 (p. 9.3.3) | LV 212-1:2015-01 (p. 9.3.3) | LV 212-2:2015-01 (p. 9.3.3) | LV 216-1:2015-07 (p. 9.3.3) | LV 216-2:2017-02 (p. 9.3.3) | VW 60306-2:2013-04 (p. 9.3.3) | VW 75209-1:2015-01 (p. 9.3.3) | VW 75209-2:2015-01 (p. 9.3.3) | MBN LV 112-1:2016-03 (p. 9.3.3) | MBN 50112-1:2023-06 (p. 12.3.4) | MBN LV 112-2:2012-01 (p. 8.4.4) | MBN 50112-2:2023-05 (p. 12.4.4) | MBN 50216-1:2023-07 (p. 12.4.4) | MBN LV 212-1:2017-08 (p. 9.3.3) | MBN 50212-1:2023-04 (p. 12.4.3) | MBN LV 216-2:2017-07 (p. 9.3.3) | MBN 50112-4:2024-06 (p. 12.3.5) | GS 95007-1-1:2013-05 (p. 9.3.3) | GS 95007-1-2:2013-05 (p. 9.3.3) | GS 95007-3-1:2015-08 (p. 9.3.3) | GS 95007-3-2:2015-09 (p. 9.3.3) | GS 95007-6-1:2016-03 (p. 9.3.3) | GS 95007-6-2:2017-04 (p. 9.3.3) Kable / Cables Wlasciwosci slizgowe kabli / Sliding behavior of the cable\nZakres:\nOdwazniki 5 N, 10 N\nSrednice rolek 20 mm, 30 mm, 40 mm, 50 mm, 60 mm, 80 mm\nWeights 5 N, 10 N\nRoll diameters 20 mm, 30 mm, 40 mm, 50 mm, 60 mm, 80 mm LV 112-1:2013-04 (p. 9.3.3) | LV 112-1:2014-04 (p. 9.3.3) | LV 112-2:2007-11 (p. 8.4.4) | LV 112-2:2013-04 (p. 9.3.3) | LV 212-1:2015-01 (p. 9.3.3) | LV 212-2:2015-01 (p. 9.3.3) | LV 216-1:2015-07 (p. 9.3.3) | LV 216-2:2017-02 (p. 9.3.3) | VW 60306-2:2013-04 (p. 9.3.3) | VW 75209-1:2015-01 (p. 9.3.3) | VW 75209-2:2015-01 (p. 9.3.3) | MBN LV 112-1:2016-03 (p. 9.3.3) | MBN 50112-1:2023-06 (p. 12.3.4) | MBN LV 112-2:2012-01 (p. 8.4.4) | MBN 50112-2:2023-05 (p. 12.4.4) | MBN 50216-1:2023-07 (p. 12.4.4) | MBN LV 212-1:2017-08 (p. 9.3.3) | MBN 50212-1:2023-04 (p. 12.4.3) | MBN LV 216-2:2017-07 (p. 9.3.3) | MBN 50112-4:2024-06 (p. 12.3.5) | GS 95007-1-1:2013-05 (p. 9.3.3) | GS 95007-1-2:2013-05 (p. 9.3.3) | GS 95007-3-1:2015-08 (p. 9.3.3) | GS 95007-3-2:2015-09 (p. 9.3.3) | GS 95007-6-1:2016-03 (p. 9.3.3) | GS 95007-6-2:2017-04 (p. 9.3.3)","categories":["other"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d98a","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Sprawdzenie budowy kabla / Cable structure test","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Sprawdzenie budowy kabla / Cable structure test","reference":"LV 212-1:2015-01 (p. 9.1) | LV 212-2:2015-01 (p. 9.1) | LV 216-1:2015-07 (p. 9.1) | LV 216-2:2017-02 (p. 9.1) | VW 75209-1:2015-01 (p. 9.1) | VW 75209-1:2021-12 (p. 9.2.1) | VW 75209-2:2015-01 (p. 9.1) | VW 75210-1:2023-06 (p. 9.2) | VW 75210-1:2024-08 (p. 9.2.1) | VW 75210-2:2023-06 (p. 9.2.2) | MBN LV 212-1:2017-08 (p. 9.1) | MBN LV 216-2:2017-07 (p. 9.1) | MBN 50216-1:2023-07 (p. 12.2) | GS 95007-3-1:2015-08 (p. 9.1) | GS 95007-3-2:2015-09 (p. 9.1) | GS 95007-6-1:2016-03 (p. 9.1) | GS 95007-6-2:2017-04 (p. 9.1)","norm_bases":["LV 212-1:2015-01 (p. 9.1)","LV 212-2:2015-01 (p. 9.1)","LV 216-1:2015-07 (p. 9.1)","LV 216-2:2017-02 (p. 9.1)","VW 75209-1:2015-01 (p. 9.1)","VW 75209-1:2021-12 (p. 9.2.1)","VW 75209-2:2015-01 (p. 9.1)","VW 75210-1:2023-06 (p. 9.2)","VW 75210-1:2024-08 (p. 9.2.1)","VW 75210-2:2023-06 (p. 9.2.2)","MBN LV 212-1:2017-08 (p. 9.1)","MBN LV 216-2:2017-07 (p. 9.1)","MBN 50216-1:2023-07 (p. 12.2)","GS 95007-3-1:2015-08 (p. 9.1)","GS 95007-3-2:2015-09 (p. 9.1)","GS 95007-6-1:2016-03 (p. 9.1)","GS 95007-6-2:2017-04 (p. 9.1)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Sprawdzenie budowy kabla / Cable structure test LV 212-1:2015-01 (p. 9.1) | LV 212-2:2015-01 (p. 9.1) | LV 216-1:2015-07 (p. 9.1) | LV 216-2:2017-02 (p. 9.1) | VW 75209-1:2015-01 (p. 9.1) | VW 75209-1:2021-12 (p. 9.2.1) | VW 75209-2:2015-01 (p. 9.1) | VW 75210-1:2023-06 (p. 9.2) | VW 75210-1:2024-08 (p. 9.2.1) | VW 75210-2:2023-06 (p. 9.2.2) | MBN LV 212-1:2017-08 (p. 9.1) | MBN LV 216-2:2017-07 (p. 9.1) | MBN 50216-1:2023-07 (p. 12.2) | GS 95007-3-1:2015-08 (p. 9.1) | GS 95007-3-2:2015-09 (p. 9.1) | GS 95007-6-1:2016-03 (p. 9.1) | GS 95007-6-2:2017-04 (p. 9.1) Kable / Cables Sprawdzenie budowy kabla / Cable structure test LV 212-1:2015-01 (p. 9.1) | LV 212-2:2015-01 (p. 9.1) | LV 216-1:2015-07 (p. 9.1) | LV 216-2:2017-02 (p. 9.1) | VW 75209-1:2015-01 (p. 9.1) | VW 75209-1:2021-12 (p. 9.2.1) | VW 75209-2:2015-01 (p. 9.1) | VW 75210-1:2023-06 (p. 9.2) | VW 75210-1:2024-08 (p. 9.2.1) | VW 75210-2:2023-06 (p. 9.2.2) | MBN LV 212-1:2017-08 (p. 9.1) | MBN LV 216-2:2017-07 (p. 9.1) | MBN 50216-1:2023-07 (p. 12.2) | GS 95007-3-1:2015-08 (p. 9.1) | GS 95007-3-2:2015-09 (p. 9.1) | GS 95007-6-1:2016-03 (p. 9.1) | GS 95007-6-2:2017-04 (p. 9.1)","categories":["other"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d98b","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Minimalna grubość ścianki kabli skręconych / Minimum wall thickness of twisted cables","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Minimalna grubość ścianki kabli skręconych / Minimum wall thickness of twisted cables","reference":"LV 122:2015-05 (p. 11.1.1) | LV 122:2016-02 (p. 11.2.1) | VW 75205:2019-11 (p. 11.1.1) | VW 75205:2024-04 (p. 11.2.2) | VW 75205:2023-05 (p. 11.1.1) | MBN LV 122:2017-06 (p. 11.2.1) | MBN 50122:2023-07 (p. 13.2.2) | GS 95007-1-5:2015-07 (p. 11.1.1)","norm_bases":["LV 122:2015-05 (p. 11.1.1)","LV 122:2016-02 (p. 11.2.1)","VW 75205:2019-11 (p. 11.1.1)","VW 75205:2024-04 (p. 11.2.2)","VW 75205:2023-05 (p. 11.1.1)","MBN LV 122:2017-06 (p. 11.2.1)","MBN 50122:2023-07 (p. 13.2.2)","GS 95007-1-5:2015-07 (p. 11.1.1)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Minimalna grubość ścianki kabli skręconych / Minimum wall thickness of twisted cables LV 122:2015-05 (p. 11.1.1) | LV 122:2016-02 (p. 11.2.1) | VW 75205:2019-11 (p. 11.1.1) | VW 75205:2024-04 (p. 11.2.2) | VW 75205:2023-05 (p. 11.1.1) | MBN LV 122:2017-06 (p. 11.2.1) | MBN 50122:2023-07 (p. 13.2.2) | GS 95007-1-5:2015-07 (p. 11.1.1) Kable / Cables Minimalna grubosc scianki kabli skreconych / Minimum wall thickness of twisted cables LV 122:2015-05 (p. 11.1.1) | LV 122:2016-02 (p. 11.2.1) | VW 75205:2019-11 (p. 11.1.1) | VW 75205:2024-04 (p. 11.2.2) | VW 75205:2023-05 (p. 11.1.1) | MBN LV 122:2017-06 (p. 11.2.1) | MBN 50122:2023-07 (p. 13.2.2) | GS 95007-1-5:2015-07 (p. 11.1.1)","categories":["other"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d98c","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Średnica zewnętrzna kabli skręconych (kalkulowana) / Outside diameter of twisted cables (calculated)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Średnica zewnętrzna kabli skręconych (kalkulowana) / Outside diameter of twisted cables (calculated)","reference":"LV 122:2015-05 (p. 11.1.2) | LV 122:2016-02 (p. 11.2.2) | VW 75205:2019-11 (p. 11.1.2) | VW 75205:2023-05 (p. 11.1.2) | VW 75205:2024-04 (p. 11.2.3) | MBN LV 122:2017-06 (p. 11.2.2) | MBN 50122:2023-07 (p. 13.2.3) | GS 95007-1-5:2015-07 (p. 11.1.2)","norm_bases":["LV 122:2015-05 (p. 11.1.2)","LV 122:2016-02 (p. 11.2.2)","VW 75205:2019-11 (p. 11.1.2)","VW 75205:2023-05 (p. 11.1.2)","VW 75205:2024-04 (p. 11.2.3)","MBN LV 122:2017-06 (p. 11.2.2)","MBN 50122:2023-07 (p. 13.2.3)","GS 95007-1-5:2015-07 (p. 11.1.2)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Średnica zewnętrzna kabli skręconych (kalkulowana) / Outside diameter of twisted cables (calculated) LV 122:2015-05 (p. 11.1.2) | LV 122:2016-02 (p. 11.2.2) | VW 75205:2019-11 (p. 11.1.2) | VW 75205:2023-05 (p. 11.1.2) | VW 75205:2024-04 (p. 11.2.3) | MBN LV 122:2017-06 (p. 11.2.2) | MBN 50122:2023-07 (p. 13.2.3) | GS 95007-1-5:2015-07 (p. 11.1.2) Kable / Cables Srednica zewnetrzna kabli skreconych (kalkulowana) / Outside diameter of twisted cables (calculated) LV 122:2015-05 (p. 11.1.2) | LV 122:2016-02 (p. 11.2.2) | VW 75205:2019-11 (p. 11.1.2) | VW 75205:2023-05 (p. 11.1.2) | VW 75205:2024-04 (p. 11.2.3) | MBN LV 122:2017-06 (p. 11.2.2) | MBN 50122:2023-07 (p. 13.2.3) | GS 95007-1-5:2015-07 (p. 11.1.2)","categories":["other"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d98d","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Długość skrętu / Lay length","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Długość skrętu / Lay length","reference":"ISO 19642-2:2023 (p. 6.2.5) | LV 122:2015-05 (p. 11.1.3) | LV 122:2016-02 (p. 11.2.3) | VW 75205:2019-11 (p. 11.1.3) | VW 75205:2023-05 (p. 11.1.3) | VW 75205:2024-04 (p. 11.2.4) | MBN LV 122:2017-06 (p. 11.2.3) | MBN 50122:2023-07 (p. 13.2.4) | GS 95007-1-5:2015-07 (p. 11.1.3)","norm_bases":["ISO 19642-2:2023 (p. 6.2.5)","LV 122:2015-05 (p. 11.1.3)","LV 122:2016-02 (p. 11.2.3)","VW 75205:2019-11 (p. 11.1.3)","VW 75205:2023-05 (p. 11.1.3)","VW 75205:2024-04 (p. 11.2.4)","MBN LV 122:2017-06 (p. 11.2.3)","MBN 50122:2023-07 (p. 13.2.4)","GS 95007-1-5:2015-07 (p. 11.1.3)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Długość skrętu / Lay length ISO 19642-2:2023 (p. 6.2.5) | LV 122:2015-05 (p. 11.1.3) | LV 122:2016-02 (p. 11.2.3) | VW 75205:2019-11 (p. 11.1.3) | VW 75205:2023-05 (p. 11.1.3) | VW 75205:2024-04 (p. 11.2.4) | MBN LV 122:2017-06 (p. 11.2.3) | MBN 50122:2023-07 (p. 13.2.4) | GS 95007-1-5:2015-07 (p. 11.1.3) Kable / Cables Dlugosc skretu / Lay length ISO 19642-2:2023 (p. 6.2.5) | LV 122:2015-05 (p. 11.1.3) | LV 122:2016-02 (p. 11.2.3) | VW 75205:2019-11 (p. 11.1.3) | VW 75205:2023-05 (p. 11.1.3) | VW 75205:2024-04 (p. 11.2.4) | MBN LV 122:2017-06 (p. 11.2.3) | MBN 50122:2023-07 (p. 13.2.4) | GS 95007-1-5:2015-07 (p. 11.1.3)","categories":["other"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d98e","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Trwałość oznaczeń kabli / Durability of cable marking","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Trwałość oznaczeń kabli / Durability of cable marking","reference":"ISO 19642-2:2019-01 (p. 5.4.12; 6.4.11) | ISO 19642-2:2023 (p. 5.5.12; 6.5.11) | ISO 19642-3:2019-01 (p. 5.5.12) | ISO 19642-4:2019-01 (p. 5.5.12) | ISO 19642-5:2019-01 (p. 5.5.12) | ISO 19642-6:2019-01 (p. 5.5.12) | ISO 19642-7:2019-01 (p. 6.5.11) | ISO 19642-8:2019-01 (p. 6.5.11) | ISO 19642-9:2019-01 (p. 6.5.11) | ISO 19642-10:2019-01 (p. 6.5.11) | ISO 14572:2011-10 (p. 5.18) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.18) | ISO 6722-2:2013-12-01 (p. 5.18) | LV 112-1:2013-04 (p. 9.6.11) | LV 112-1:2014-04 (p. 9.6.11) | LV 112-2:2007-11 (p. 8.7.10) | LV 112-2:2013-04 (p. 9.6.11) | LV 212-1:2015-01 (p. 9.6.10) | LV 212-2:2015-01 (p. 9.6.10) | LV 216-1:2015-07 (p. 9.6.11) | LV 216-2:2017-02 (p. 9.6.10) | VW 60306-1:2018-09-01 (p. 9.6.11) | VW 60306-1:2021-10 (p. 9.7.11) | VW 60306-2:2013-04 (p. 9.6.11) | VW 60306-2:2021-11 (p. 9.7.11) | VW 60306-4:2021-12 (p. 9.7.11) | VW 75209-1:2015-01 (p. 9.6.10) | VW 75209-1:2021-12 (p. 9.7.9) | VW 75209-2:2015-01 (p. 9.6.10) | VW 75209-2:2021-12 (p. 9.7.9) | VW 75210-1:2023-06 (p. 9.7.11) | VW 75210-1:2024-08 (p. 9.7.11) | VW 75210-2:2023-06 (p. 9.7.10) | MBN LV 112-1:2016-03 (p. 9.6.11) | MBN 50112-1:2023-06 (p. 12.6.11) | MBN LV 112-2:2012-01 (p. 8.7.10) | MBN 50112-2: 2023-05 (p. 12.7.10)","norm_bases":["ISO 19642-2:2019-01 (p. 5.4.12; 6.4.11)","ISO 19642-2:2023 (p. 5.5.12; 6.5.11)","ISO 19642-3:2019-01 (p. 5.5.12)","ISO 19642-4:2019-01 (p. 5.5.12)","ISO 19642-5:2019-01 (p. 5.5.12)","ISO 19642-6:2019-01 (p. 5.5.12)","ISO 19642-7:2019-01 (p. 6.5.11)","ISO 19642-8:2019-01 (p. 6.5.11)","ISO 19642-9:2019-01 (p. 6.5.11)","ISO 19642-10:2019-01 (p. 6.5.11)","ISO 14572:2011-10 (p. 5.18)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.18)","ISO 6722-2:2013-12-01 (p. 5.18)","LV 112-1:2013-04 (p. 9.6.11)","LV 112-1:2014-04 (p. 9.6.11)","LV 112-2:2007-11 (p. 8.7.10)","LV 112-2:2013-04 (p. 9.6.11)","LV 212-1:2015-01 (p. 9.6.10)","LV 212-2:2015-01 (p. 9.6.10)","LV 216-1:2015-07 (p. 9.6.11)","LV 216-2:2017-02 (p. 9.6.10)","VW 60306-1:2018-09-01 (p. 9.6.11)","VW 60306-1:2021-10 (p. 9.7.11)","VW 60306-2:2013-04 (p. 9.6.11)","VW 60306-2:2021-11 (p. 9.7.11)","VW 60306-4:2021-12 (p. 9.7.11)","VW 75209-1:2015-01 (p. 9.6.10)","VW 75209-1:2021-12 (p. 9.7.9)","VW 75209-2:2015-01 (p. 9.6.10)","VW 75209-2:2021-12 (p. 9.7.9)","VW 75210-1:2023-06 (p. 9.7.11)","VW 75210-1:2024-08 (p. 9.7.11)","VW 75210-2:2023-06 (p. 9.7.10)","MBN LV 112-1:2016-03 (p. 9.6.11)","MBN 50112-1:2023-06 (p. 12.6.11)","MBN LV 112-2:2012-01 (p. 8.7.10)","MBN 50112-2: 2023-05 (p. 12.7.10)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Trwałość oznaczeń kabli / Durability of cable marking ISO 19642-2:2019-01 (p. 5.4.12; 6.4.11) | ISO 19642-2:2023 (p. 5.5.12; 6.5.11) | ISO 19642-3:2019-01 (p. 5.5.12) | ISO 19642-4:2019-01 (p. 5.5.12) | ISO 19642-5:2019-01 (p. 5.5.12) | ISO 19642-6:2019-01 (p. 5.5.12) | ISO 19642-7:2019-01 (p. 6.5.11) | ISO 19642-8:2019-01 (p. 6.5.11) | ISO 19642-9:2019-01 (p. 6.5.11) | ISO 19642-10:2019-01 (p. 6.5.11) | ISO 14572:2011-10 (p. 5.18) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.18) | ISO 6722-2:2013-12-01 (p. 5.18) | LV 112-1:2013-04 (p. 9.6.11) | LV 112-1:2014-04 (p. 9.6.11) | LV 112-2:2007-11 (p. 8.7.10) | LV 112-2:2013-04 (p. 9.6.11) | LV 212-1:2015-01 (p. 9.6.10) | LV 212-2:2015-01 (p. 9.6.10) | LV 216-1:2015-07 (p. 9.6.11) | LV 216-2:2017-02 (p. 9.6.10) | VW 60306-1:2018-09-01 (p. 9.6.11) | VW 60306-1:2021-10 (p. 9.7.11) | VW 60306-2:2013-04 (p. 9.6.11) | VW 60306-2:2021-11 (p. 9.7.11) | VW 60306-4:2021-12 (p. 9.7.11) | VW 75209-1:2015-01 (p. 9.6.10) | VW 75209-1:2021-12 (p. 9.7.9) | VW 75209-2:2015-01 (p. 9.6.10) | VW 75209-2:2021-12 (p. 9.7.9) | VW 75210-1:2023-06 (p. 9.7.11) | VW 75210-1:2024-08 (p. 9.7.11) | VW 75210-2:2023-06 (p. 9.7.10) | MBN LV 112-1:2016-03 (p. 9.6.11) | MBN 50112-1:2023-06 (p. 12.6.11) | MBN LV 112-2:2012-01 (p. 8.7.10) | MBN 50112-2: 2023-05 (p. 12.7.10) Kable / Cables Trwalosc oznaczen kabli / Durability of cable marking ISO 19642-2:2019-01 (p. 5.4.12; 6.4.11) | ISO 19642-2:2023 (p. 5.5.12; 6.5.11) | ISO 19642-3:2019-01 (p. 5.5.12) | ISO 19642-4:2019-01 (p. 5.5.12) | ISO 19642-5:2019-01 (p. 5.5.12) | ISO 19642-6:2019-01 (p. 5.5.12) | ISO 19642-7:2019-01 (p. 6.5.11) | ISO 19642-8:2019-01 (p. 6.5.11) | ISO 19642-9:2019-01 (p. 6.5.11) | ISO 19642-10:2019-01 (p. 6.5.11) | ISO 14572:2011-10 (p. 5.18) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.18) | ISO 6722-2:2013-12-01 (p. 5.18) | LV 112-1:2013-04 (p. 9.6.11) | LV 112-1:2014-04 (p. 9.6.11) | LV 112-2:2007-11 (p. 8.7.10) | LV 112-2:2013-04 (p. 9.6.11) | LV 212-1:2015-01 (p. 9.6.10) | LV 212-2:2015-01 (p. 9.6.10) | LV 216-1:2015-07 (p. 9.6.11) | LV 216-2:2017-02 (p. 9.6.10) | VW 60306-1:2018-09-01 (p. 9.6.11) | VW 60306-1:2021-10 (p. 9.7.11) | VW 60306-2:2013-04 (p. 9.6.11) | VW 60306-2:2021-11 (p. 9.7.11) | VW 60306-4:2021-12 (p. 9.7.11) | VW 75209-1:2015-01 (p. 9.6.10) | VW 75209-1:2021-12 (p. 9.7.9) | VW 75209-2:2015-01 (p. 9.6.10) | VW 75209-2:2021-12 (p. 9.7.9) | VW 75210-1:2023-06 (p. 9.7.11) | VW 75210-1:2024-08 (p. 9.7.11) | VW 75210-2:2023-06 (p. 9.7.10) | MBN LV 112-1:2016-03 (p. 9.6.11) | MBN 50112-1:2023-06 (p. 12.6.11) | MBN LV 112-2:2012-01 (p. 8.7.10) | MBN 50112-2: 2023-05 (p. 12.7.10)","categories":["other"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d98f","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Trwałość oznaczeń kabli / Durability of cable marking","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Trwałość oznaczeń kabli / Durability of cable marking","reference":"MBN 50216-1:2023-07 (p. 12.7.10) | MBN LV 212-1:2017-08 (p. 9.6.10) | MBN 50212-1:2023-04 (p. 12.7.10) | MBN LV 216-2:2017-07 (p. 9.6.10) | MBN 50112-4:2024-06 (p. 12.6.11) | GS 95007-1-1:2013-05 (p. 9.6.11) | GS 95007-1-2:2013-05 (p. 9.6.11) | GS 95007-3-1:2015-08 (p. 9.6.10) | GS 95007-3-2:2015-09 (p. 9.6.10) | GS 95007-6-1:2016-03 (p. 9.6.11) | GS 95007-6-2:2017-04 (p. 9.6.10)","norm_bases":["MBN 50216-1:2023-07 (p. 12.7.10)","MBN LV 212-1:2017-08 (p. 9.6.10)","MBN 50212-1:2023-04 (p. 12.7.10)","MBN LV 216-2:2017-07 (p. 9.6.10)","MBN 50112-4:2024-06 (p. 12.6.11)","GS 95007-1-1:2013-05 (p. 9.6.11)","GS 95007-1-2:2013-05 (p. 9.6.11)","GS 95007-3-1:2015-08 (p. 9.6.10)","GS 95007-3-2:2015-09 (p. 9.6.10)","GS 95007-6-1:2016-03 (p. 9.6.11)","GS 95007-6-2:2017-04 (p. 9.6.10)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Trwałość oznaczeń kabli / Durability of cable marking MBN 50216-1:2023-07 (p. 12.7.10) | MBN LV 212-1:2017-08 (p. 9.6.10) | MBN 50212-1:2023-04 (p. 12.7.10) | MBN LV 216-2:2017-07 (p. 9.6.10) | MBN 50112-4:2024-06 (p. 12.6.11) | GS 95007-1-1:2013-05 (p. 9.6.11) | GS 95007-1-2:2013-05 (p. 9.6.11) | GS 95007-3-1:2015-08 (p. 9.6.10) | GS 95007-3-2:2015-09 (p. 9.6.10) | GS 95007-6-1:2016-03 (p. 9.6.11) | GS 95007-6-2:2017-04 (p. 9.6.10) Kable / Cables Trwalosc oznaczen kabli / Durability of cable marking MBN 50216-1:2023-07 (p. 12.7.10) | MBN LV 212-1:2017-08 (p. 9.6.10) | MBN 50212-1:2023-04 (p. 12.7.10) | MBN LV 216-2:2017-07 (p. 9.6.10) | MBN 50112-4:2024-06 (p. 12.6.11) | GS 95007-1-1:2013-05 (p. 9.6.11) | GS 95007-1-2:2013-05 (p. 9.6.11) | GS 95007-3-1:2015-08 (p. 9.6.10) | GS 95007-3-2:2015-09 (p. 9.6.10) | GS 95007-6-1:2016-03 (p. 9.6.11) | GS 95007-6-2:2017-04 (p. 9.6.10)","categories":["other"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d990","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Długość nieskręconych końców kabli / Open length at the ends","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Długość nieskręconych końców kabli / Open length at the ends","reference":"LV 122:2015-05 (p. 11.1.7) | LV 122:2016-02 (p. 11.2.7) | VW 75205:2019-11 (p. 11.1.5) | VW 75205:2023-05 (p. 11.1.5) | VW 75205:2024-04 (p. 11.2.6) | MBN LV 122:2017-06 (p. 11.2.7) | MBN 50122:2023-07 (p. 13.2.8) | GS 95007-1-5:2015-07 (p. 11.1.7)","norm_bases":["LV 122:2015-05 (p. 11.1.7)","LV 122:2016-02 (p. 11.2.7)","VW 75205:2019-11 (p. 11.1.5)","VW 75205:2023-05 (p. 11.1.5)","VW 75205:2024-04 (p. 11.2.6)","MBN LV 122:2017-06 (p. 11.2.7)","MBN 50122:2023-07 (p. 13.2.8)","GS 95007-1-5:2015-07 (p. 11.1.7)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Długość nieskręconych końców kabli / Open length at the ends LV 122:2015-05 (p. 11.1.7) | LV 122:2016-02 (p. 11.2.7) | VW 75205:2019-11 (p. 11.1.5) | VW 75205:2023-05 (p. 11.1.5) | VW 75205:2024-04 (p. 11.2.6) | MBN LV 122:2017-06 (p. 11.2.7) | MBN 50122:2023-07 (p. 13.2.8) | GS 95007-1-5:2015-07 (p. 11.1.7) Kable / Cables Dlugosc nieskreconych koncow kabli / Open length at the ends LV 122:2015-05 (p. 11.1.7) | LV 122:2016-02 (p. 11.2.7) | VW 75205:2019-11 (p. 11.1.5) | VW 75205:2023-05 (p. 11.1.5) | VW 75205:2024-04 (p. 11.2.6) | MBN LV 122:2017-06 (p. 11.2.7) | MBN 50122:2023-07 (p. 13.2.8) | GS 95007-1-5:2015-07 (p. 11.1.7)","categories":["other"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9ef505a4e73262d7f6d991","lab_id":"6a9eea8db186769edc1f54f2","country":"PL","accr_number":"AB 1974","accr_body":"PCA","test_object":"Kable / Cables","methodology":"Stabilność termiczna PVC / Thermal stability of PVC","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stabilność termiczna PVC / Thermal stability of PVC","reference":"IEC 60811-405:2012 | LV 112-1:2013-04 (p. 9.2.5) | LV 112-1:2014-04 (p. 9.2.5) | LV 112-2:2007-11 (p. 8.3) | LV 112-2:2013-04 (p. 9.2) | LV 212-1:2015-01 (p. 9.2.5) | LV 212-2:2015-01 (p. 9.2.5) | LV 216-1:2015-07 (p. 9.2.5) | LV 216-2:2017-02 (p. 9.2.5) | VW 60306-1:2018-09 (p. 9.2.2) | VW 60306-1:2021-10 (p. 9.3.3) | VW 60306-2:2013-04 (p. 9.2) | VW 60306-2:2021-11 (p. 9.3.3) | VW 60306-4:2021-12 (p. 9.3.3) | VW 75209-1:2015-01 (p. 9.2.5) | VW 75209-1:2021-12 (p. 9.3.3) | VW 75209-2:2015-01 (p. 9.2.5) | VW 75209-2:2021-12 (p. 9.3.3) | VW 75210-1:2023-06 (p. 9.3.3) | VW 75210-1:2024-08 (p. 9.3.3) | VW 75210-2:2023-06 (p. 9.3.3) | MBN LV 112-1:2016-03 (p. 9.2.5) | MBN 50112-1:2023-06 (p. 12.2.6) | MBN LV 112-2:2012-01 (p. 8.3) | MBN 50112-2: 2023-05 (p. 12.3) | MBN 50216-1:2023-07 (p. 12.3.6) | MBN LV 212-1:2017-08 (p. 9.2.5) | MBN 50212-1:2023-04 (p. 12.3.6) | MBN LV 216-2:2017-07 (p. 9.2.5) | MBN 50112-4:2024-06 (p. 12.2.6) | GS 95007-1-1:2013-05 (p. 9.2.5) | GS 95007-1-2:2013-05 (p. 9.2) | GS 95007-3-1:2015-08 (p. 9.2.5) | GS 95007-3-2:2015-09 (p. 9.2.5) | GS 95007-6-1:2016-03 (p. 9.2.5) | GS 95007-6-2:2017-04 (p. 9.2.5)","norm_bases":["IEC 60811-405:2012","LV 112-1:2013-04 (p. 9.2.5)","LV 112-1:2014-04 (p. 9.2.5)","LV 112-2:2007-11 (p. 8.3)","LV 112-2:2013-04 (p. 9.2)","LV 212-1:2015-01 (p. 9.2.5)","LV 212-2:2015-01 (p. 9.2.5)","LV 216-1:2015-07 (p. 9.2.5)","LV 216-2:2017-02 (p. 9.2.5)","VW 60306-1:2018-09 (p. 9.2.2)","VW 60306-1:2021-10 (p. 9.3.3)","VW 60306-2:2013-04 (p. 9.2)","VW 60306-2:2021-11 (p. 9.3.3)","VW 60306-4:2021-12 (p. 9.3.3)","VW 75209-1:2015-01 (p. 9.2.5)","VW 75209-1:2021-12 (p. 9.3.3)","VW 75209-2:2015-01 (p. 9.2.5)","VW 75209-2:2021-12 (p. 9.3.3)","VW 75210-1:2023-06 (p. 9.3.3)","VW 75210-1:2024-08 (p. 9.3.3)","VW 75210-2:2023-06 (p. 9.3.3)","MBN LV 112-1:2016-03 (p. 9.2.5)","MBN 50112-1:2023-06 (p. 12.2.6)","MBN LV 112-2:2012-01 (p. 8.3)","MBN 50112-2: 2023-05 (p. 12.3)","MBN 50216-1:2023-07 (p. 12.3.6)","MBN LV 212-1:2017-08 (p. 9.2.5)","MBN 50212-1:2023-04 (p. 12.3.6)","MBN LV 216-2:2017-07 (p. 9.2.5)","MBN 50112-4:2024-06 (p. 12.2.6)","GS 95007-1-1:2013-05 (p. 9.2.5)","GS 95007-1-2:2013-05 (p. 9.2)","GS 95007-3-1:2015-08 (p. 9.2.5)","GS 95007-3-2:2015-09 (p. 9.2.5)","GS 95007-6-1:2016-03 (p. 9.2.5)","GS 95007-6-2:2017-04 (p. 9.2.5)"],"lab_section":"Product Validation and Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kable / Cables Stabilność termiczna PVC / Thermal stability of PVC IEC 60811-405:2012 | LV 112-1:2013-04 (p. 9.2.5) | LV 112-1:2014-04 (p. 9.2.5) | LV 112-2:2007-11 (p. 8.3) | LV 112-2:2013-04 (p. 9.2) | LV 212-1:2015-01 (p. 9.2.5) | LV 212-2:2015-01 (p. 9.2.5) | LV 216-1:2015-07 (p. 9.2.5) | LV 216-2:2017-02 (p. 9.2.5) | VW 60306-1:2018-09 (p. 9.2.2) | VW 60306-1:2021-10 (p. 9.3.3) | VW 60306-2:2013-04 (p. 9.2) | VW 60306-2:2021-11 (p. 9.3.3) | VW 60306-4:2021-12 (p. 9.3.3) | VW 75209-1:2015-01 (p. 9.2.5) | VW 75209-1:2021-12 (p. 9.3.3) | VW 75209-2:2015-01 (p. 9.2.5) | VW 75209-2:2021-12 (p. 9.3.3) | VW 75210-1:2023-06 (p. 9.3.3) | VW 75210-1:2024-08 (p. 9.3.3) | VW 75210-2:2023-06 (p. 9.3.3) | MBN LV 112-1:2016-03 (p. 9.2.5) | MBN 50112-1:2023-06 (p. 12.2.6) | MBN LV 112-2:2012-01 (p. 8.3) | MBN 50112-2: 2023-05 (p. 12.3) | MBN 50216-1:2023-07 (p. 12.3.6) | MBN LV 212-1:2017-08 (p. 9.2.5) | MBN 50212-1:2023-04 (p. 12.3.6) | MBN LV 216-2:2017-07 (p. 9.2.5) | MBN 50112-4:2024-06 (p. 12.2.6) | GS 95007-1-1:2013-05 (p. 9.2.5) | GS 95007-1-2:2013-05 (p. 9.2) | GS 95007-3-1:2015-08 (p. 9.2.5) | GS 95007-3-2:2015-09 (p. 9.2.5) | GS 95007-6-1:2016-03 (p. 9.2.5) | GS 95007-6-2:2017-04 (p. 9.2.5) Kable / Cables Stabilnosc termiczna PVC / Thermal stability of PVC IEC 60811-405:2012 | LV 112-1:2013-04 (p. 9.2.5) | LV 112-1:2014-04 (p. 9.2.5) | LV 112-2:2007-11 (p. 8.3) | LV 112-2:2013-04 (p. 9.2) | LV 212-1:2015-01 (p. 9.2.5) | LV 212-2:2015-01 (p. 9.2.5) | LV 216-1:2015-07 (p. 9.2.5) | LV 216-2:2017-02 (p. 9.2.5) | VW 60306-1:2018-09 (p. 9.2.2) | VW 60306-1:2021-10 (p. 9.3.3) | VW 60306-2:2013-04 (p. 9.2) | VW 60306-2:2021-11 (p. 9.3.3) | VW 60306-4:2021-12 (p. 9.3.3) | VW 75209-1:2015-01 (p. 9.2.5) | VW 75209-1:2021-12 (p. 9.3.3) | VW 75209-2:2015-01 (p. 9.2.5) | VW 75209-2:2021-12 (p. 9.3.3) | VW 75210-1:2023-06 (p. 9.3.3) | VW 75210-1:2024-08 (p. 9.3.3) | VW 75210-2:2023-06 (p. 9.3.3) | MBN LV 112-1:2016-03 (p. 9.2.5) | MBN 50112-1:2023-06 (p. 12.2.6) | MBN LV 112-2:2012-01 (p. 8.3) | MBN 50112-2: 2023-05 (p. 12.3) | MBN 50216-1:2023-07 (p. 12.3.6) | MBN LV 212-1:2017-08 (p. 9.2.5) | MBN 50212-1:2023-04 (p. 12.3.6) | MBN LV 216-2:2017-07 (p. 9.2.5) | MBN 50112-4:2024-06 (p. 12.2.6) | GS 95007-1-1:2013-05 (p. 9.2.5) | GS 95007-1-2:2013-05 (p. 9.2) | GS 95007-3-1:2015-08 (p. 9.2.5) | GS 95007-3-2:2015-09 (p. 9.2.5) | GS 95007-6-1:2016-03 (p. 9.2.5) | GS 95007-6-2:2017-04 (p. 9.2.5)","categories":["other"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code"}],"has_pdf":false}