{"lab":{"_id":"6a9eea89b186769edc1f54e2","country":"PL","accr_number":"AB 1966","accr_body":"PCA","address":"ul. Bratysławska 52, 94-112 Łódź","categories":["construction","water"],"city":"Łódź","discovered_at":"2026-09-07T16:47:05.781Z","email_confidence":"high","email_mx":null,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201966,podmiot.html","fields_of_testing":[{"codes":"J/5/P","pl":"Badania mechaniczne i pobieranie próbek wyrobów i materiałów budowlanych","en":"Mechanical tests and sampling of building materials and items"},{"codes":"J/5","pl":"Badania mechaniczne wyrobów i materiałów budowlanych","en":"Mechanical tests of building materials and items"},{"codes":"N/5/P","pl":"Badania właściwości fizycznych i pobieranie próbek wyrobów i materiałów budowlanych","en":"Tests of physical properties and sampling of building materials and items"},{"codes":"N/5","pl":"Badania właściwości fizycznych wyrobów i materiałów budowlanych","en":"Tests of physical properties of building materials and items"}],"imported_at":"2026-09-07T16:47:05.781Z","methods_count":7,"name":"Mosty Łódź Spółka Akcyjna","parse_status":"parsed","parse_version":0,"pdf_files":["AB_1966.pdf"],"scope_summary":"Badania mechaniczne, badania metalograficzne; Badania właściwości fizycznych; Pobieranie próbek, laboratoria akredytowane do pobierania próbek; Wyroby, materiały, obiekty budowlane","search_text":"mosty łódź spółka akcyjna ul. bratysławska 52, 94-112 łódź badania mechaniczne, badania metalograficzne; badania właściwości fizycznych; pobieranie próbek, laboratoria akredytowane do pobierania próbek; wyroby, materiały, obiekty budowlane ab 1966","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/9/7/e86fa4a3818948e1428f28b517562f0c/AB%201966.pdf","status":"active","updated_at":"2026-09-07T16:47:05.781Z","valid_from":"23-04-2026","valid_until":"22-04-2030","website":"www.mosty-lodz.pl","issue":{"no":"1","date":"23.04.2026"},"lab_locations":[{"name":"Laboratorium Mosty Łódź S.A.","address":"ul. Bratysławska 52","city":null,"postal":null}],"parse_date":"2026-09-07T16:47:41.476Z","parse_source":"agent-claude-code","parsed_at":"2026-09-07T16:47:41.476Z","scope_format":"PCA::pracownie+siatka4","map_coord":[51.743326,19.41887],"map_geo":"nominatim-street"},"methods":[{"_id":"6a9eeaad946e48c9e5a92756","lab_id":"6a9eea89b186769edc1f54e2","country":"PL","accr_number":"AB 1966","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Konsystencja","parameters":[],"technique":"Metoda opadu stożka","techniques":["Metoda opadu stożka"],"computed":[],"activity":"Konsystencja\nMetoda opadu stożka","reference":"PN-EN 12350-2:2019-07","norm_bases":["PN-EN 12350-2:2019-07"],"lab_section":"Laboratorium Mosty Łódź S.A.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Konsystencja\nMetoda opadu stożka PN-EN 12350-2:2019-07 Mieszanka betonowa Konsystencja\nMetoda opadu stozka PN-EN 12350-2:2019-07","categories":["construction"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eeaad946e48c9e5a92757","lab_id":"6a9eea89b186769edc1f54e2","country":"PL","accr_number":"AB 1966","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Zawartość powietrza","parameters":[{"name":"Zakres","range":"(0 - 10) %"}],"technique":"Metoda ciśnieniomierza","techniques":["Metoda ciśnieniomierza"],"computed":[],"activity":"Zawartość powietrza\nZakres (0 - 10) %\nMetoda ciśnieniomierza","reference":"PN-EN 12350-7:2019-08","norm_bases":["PN-EN 12350-7:2019-08"],"lab_section":"Laboratorium Mosty Łódź S.A.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Zawartość powietrza\nZakres (0 - 10) %\nMetoda ciśnieniomierza PN-EN 12350-7:2019-08 Mieszanka betonowa Zawartosc powietrza\nZakres (0 - 10) %\nMetoda cisnieniomierza PN-EN 12350-7:2019-08","categories":["construction"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eeaad946e48c9e5a92758","lab_id":"6a9eea89b186769edc1f54e2","country":"PL","accr_number":"AB 1966","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 12350-1:2019-07","norm_bases":["PN-EN 12350-1:2019-07"],"lab_section":"Laboratorium Mosty Łódź S.A.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Pobieranie próbek PN-EN 12350-1:2019-07 Mieszanka betonowa Pobieranie probek PN-EN 12350-1:2019-07","categories":["construction"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eeaad946e48c9e5a92759","lab_id":"6a9eea89b186769edc1f54e2","country":"PL","accr_number":"AB 1966","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres siły","range":"(300 – 3000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres siły (300 – 3000) kN","reference":"PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12390-3:2019-07"],"lab_section":"Laboratorium Mosty Łódź S.A.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na ściskanie\nZakres siły (300 – 3000) kN PN-EN 12390-3:2019-07 Beton Wytrzymalosc na sciskanie\nZakres sily (300 – 3000) kN PN-EN 12390-3:2019-07","categories":["construction"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eeaad946e48c9e5a9275a","lab_id":"6a9eea89b186769edc1f54e2","country":"PL","accr_number":"AB 1966","accr_body":"PCA","test_object":"Beton","methodology":"Gęstość","parameters":[],"technique":"Metoda: w stanie nasyconym, objętość określona na podstawie wymiarów rzeczywistych","techniques":["Metoda: w stanie nasyconym, objętość określona na podstawie wymiarów rzeczywistych"],"computed":[],"activity":"Gęstość\nMetoda: w stanie nasyconym, objętość określona na podstawie wymiarów rzeczywistych","reference":"PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","norm_bases":["PN-EN 12390-7:2019-08","PN-EN 12390-7:2019-08/AC:2021-01"],"lab_section":"Laboratorium Mosty Łódź S.A.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Gęstość\nMetoda: w stanie nasyconym, objętość określona na podstawie wymiarów rzeczywistych PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01 Beton Gestosc\nMetoda: w stanie nasyconym, objetosc okreslona na podstawie wymiarow rzeczywistych PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","categories":["construction"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eeaad946e48c9e5a9275b","lab_id":"6a9eea89b186769edc1f54e2","country":"PL","accr_number":"AB 1966","accr_body":"PCA","test_object":"Beton","methodology":"Głębokość penetracji wody pod ciśnieniem","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Głębokość penetracji wody pod ciśnieniem","reference":"PN-EN 12390-8:2019-08","norm_bases":["PN-EN 12390-8:2019-08"],"lab_section":"Laboratorium Mosty Łódź S.A.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Głębokość penetracji wody pod ciśnieniem PN-EN 12390-8:2019-08 Beton Glebokosc penetracji wody pod cisnieniem PN-EN 12390-8:2019-08","categories":["water","construction"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eeaad946e48c9e5a9275c","lab_id":"6a9eea89b186769edc1f54e2","country":"PL","accr_number":"AB 1966","accr_body":"PCA","test_object":"Beton","methodology":"Odporność na działanie mrozu","parameters":[],"technique":"Metoda: zwykła","techniques":["Metoda: zwykła"],"computed":[],"activity":"Odporność na działanie mrozu\nMetoda: zwykła","reference":"PN-B-06265:2022-08 załącznik N","norm_bases":["PN-B-06265:2022-08 załącznik N"],"lab_section":"Laboratorium Mosty Łódź S.A.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Odporność na działanie mrozu\nMetoda: zwykła PN-B-06265:2022-08 załącznik N Beton Odpornosc na dzialanie mrozu\nMetoda: zwykla PN-B-06265:2022-08 zalacznik N","categories":["construction"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code"}],"has_pdf":false}