{"lab":{"_id":"6a9eea83b186769edc1f54c8","country":"PL","accr_number":"AB 1953","accr_body":"PCA","address":"ul. Wolności 8A, 07-407 Czerwin","categories":["food"],"city":"Czerwin","discovered_at":"2026-09-07T16:46:59.723Z","email_confidence":"high","email_mx":null,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201953,podmiot.html","fields_of_testing":[{"codes":"B/22","pl":"Badania biochemiczne żywności","en":"Biochemical tests of food"},{"codes":"C/22","pl":"Badania chemiczne żywności","en":"Chemical tests of food"},{"codes":"K/22","pl":"Badania mikrobiologiczne żywności","en":"Microbiological tests of food"}],"imported_at":"2026-09-07T16:46:59.723Z","methods_count":6,"name":"MLEKOLAB Sp. z o.o.","parse_status":"parsed","parse_version":0,"pdf_files":["AB_1953.pdf"],"scope_summary":"Badania biologicznie i biochemiczne; Badania chemiczne; Badania mikrobiologiczne; Żywność","search_text":"mlekolab sp. z o.o. ul. wolności 8a, 07-407 czerwin badania biologicznie i biochemiczne; badania chemiczne; badania mikrobiologiczne; żywność ab 1953","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/9/7/fb38cb526663380295f8c381cbbd2d2f/AB%201953.pdf","status":"active","updated_at":"2026-09-07T16:46:59.723Z","valid_from":"15-12-2025","valid_until":"14-12-2029","website":"www.mlekolab.pl","issue":{"no":"1","date":"15.12.2025"},"lab_locations":[{"name":"Laboratorium Mlekolab Sp. z o.o.","address":"ul. Wolności 8A, 07-407 Czerwin","city":"Czerwin","postal":"07-407"}],"parse_date":"2026-09-07T16:47:31.259Z","parse_source":"agent-claude-code","parsed_at":"2026-09-07T16:47:31.259Z","scope_format":"PCA::pracownie+siatka4","map_coord":[52.94718,21.764492],"map_geo":"nominatim-street"},"methods":[{"_id":"6a9eeaa3946e48c9e5a92691","lab_id":"6a9eea83b186769edc1f54c8","country":"PL","accr_number":"AB 1953","accr_body":"PCA","test_object":"Mleko surowe","methodology":"Zawartość tłuszczu","parameters":[{"name":"Zakres","range":"(1,60 – 8,00) g/100 g"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"computed":[],"activity":"Zawartość tłuszczu\nZakres (1,60 – 8,00) g/100 g\nMetoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT"],"lab_section":"Laboratorium Mlekolab Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko surowe Zawartość tłuszczu\nZakres (1,60 – 8,00) g/100 g\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT Mleko surowe Zawartosc tluszczu\nZakres (1,60 – 8,00) g/100 g\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT","categories":["food"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eeaa3946e48c9e5a92692","lab_id":"6a9eea83b186769edc1f54c8","country":"PL","accr_number":"AB 1953","accr_body":"PCA","test_object":"Mleko surowe","methodology":"Zawartość białka","parameters":[{"name":"Zakres","range":"(1,40 – 7,20) g/100 g"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"computed":[],"activity":"Zawartość białka\nZakres (1,40 – 7,20) g/100 g\nMetoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT"],"lab_section":"Laboratorium Mlekolab Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko surowe Zawartość białka\nZakres (1,40 – 7,20) g/100 g\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT Mleko surowe Zawartosc bialka\nZakres (1,40 – 7,20) g/100 g\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT","categories":["food"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eeaa3946e48c9e5a92693","lab_id":"6a9eea83b186769edc1f54c8","country":"PL","accr_number":"AB 1953","accr_body":"PCA","test_object":"Mleko surowe","methodology":"Zawartość laktozy","parameters":[{"name":"Zakres","range":"(2,20 – 10,00) g/dl"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"computed":[],"activity":"Zawartość laktozy\nZakres (2,20 – 10,00) g/dl\nMetoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT"],"lab_section":"Laboratorium Mlekolab Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko surowe Zawartość laktozy\nZakres (2,20 – 10,00) g/dl\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT Mleko surowe Zawartosc laktozy\nZakres (2,20 – 10,00) g/dl\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT","categories":["food"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eeaa3946e48c9e5a92694","lab_id":"6a9eea83b186769edc1f54c8","country":"PL","accr_number":"AB 1953","accr_body":"PCA","test_object":"Mleko surowe","methodology":"Zawartość suchej masy","parameters":[{"name":"Zakres","range":"(5,40 – 27,00) g/100 g"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"computed":[],"activity":"Zawartość suchej masy\nZakres (5,40 – 27,00) g/100 g\nMetoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT"],"lab_section":"Laboratorium Mlekolab Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko surowe Zawartość suchej masy\nZakres (5,40 – 27,00) g/100 g\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT Mleko surowe Zawartosc suchej masy\nZakres (5,40 – 27,00) g/100 g\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT","categories":["food"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eeaa3946e48c9e5a92695","lab_id":"6a9eea83b186769edc1f54c8","country":"PL","accr_number":"AB 1953","accr_body":"PCA","test_object":"Mleko surowe","methodology":"Zawartość mocznika","parameters":[{"name":"Zakres","range":"(70 – 740) mg/l"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"computed":[],"activity":"Zawartość mocznika\nZakres (70 – 740) mg/l\nMetoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT"],"lab_section":"Laboratorium Mlekolab Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko surowe Zawartość mocznika\nZakres (70 – 740) mg/l\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT Mleko surowe Zawartosc mocznika\nZakres (70 – 740) mg/l\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT","categories":["food"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9eeaa3946e48c9e5a92696","lab_id":"6a9eea83b186769edc1f54c8","country":"PL","accr_number":"AB 1953","accr_body":"PCA","test_object":"Mleko surowe","methodology":"Liczba komórek somatycznych (LKS)","parameters":[{"name":"Zakres","range":"(5x103 – 2x106) komórek/ml"}],"technique":"Metoda cytometrii przepływowej","techniques":["Metoda cytometrii przepływowej"],"computed":[],"activity":"Liczba komórek somatycznych (LKS)\nZakres (5x103 – 2x106) komórek/ml\nMetoda cytometrii przepływowej","reference":"PN-EN ISO 13366-2:2007 z zastosowaniem aparatu SomaCount FC","norm_bases":["PN-EN ISO 13366-2:2007 z zastosowaniem aparatu SomaCount FC"],"lab_section":"Laboratorium Mlekolab Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko surowe Liczba komórek somatycznych (LKS)\nZakres (5x103 – 2x106) komórek/ml\nMetoda cytometrii przepływowej PN-EN ISO 13366-2:2007 z zastosowaniem aparatu SomaCount FC Mleko surowe Liczba komorek somatycznych (LKS)\nZakres (5x103 – 2x106) komorek/ml\nMetoda cytometrii przeplywowej PN-EN ISO 13366-2:2007 z zastosowaniem aparatu SomaCount FC","categories":["food"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code"}],"has_pdf":false}