{"lab":{"_id":"69ad52a3de79e566650fba9f","country":"PL","accr_number":"AB 1939","accr_body":"PCA","address":"Laboratorium Quality Assurance Flavor, Stary Gostków 42, 99-220 Wartkowice","categories":["electronics","water"],"city":"Wartkowice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":6,"name":"JTI POLSKA Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1939.pdf"],"scope_summary":"","search_text":"jti polska sp. z o.o. laboratorium quality assurance flavor, stary gostków 42, 99-220 wartkowice other electronics water pharma","status":"active","updated_at":"2026-03-08T14:51:04.103Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:04.103Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201939,podmiot.html","fields_of_testing":[{"codes":"C/24","pl":"Badania chemiczne wyrobów tytoniowych","en":"Chemical tests of tobacco products"},{"codes":"N/24","pl":"Badania właściwości fizycznych wyrobów tytoniowych","en":"Tests of physical properties of tobacco products"}],"issue":{"no":"1","date":"30.06.2025"},"parse_date":"2026-07-20T07:09:57.749Z","parse_source":"script-pdfplumber","map_coord":[51.975572,19.002248],"map_geo":"nominatim-city","has_zh":true,"has_en":true,"category_counts":{"electronics":6,"water":1},"category_scores":{"electronics":5.14,"water":0.14}},"methods":[{"_id":"6a5dc9c5f1c10c8ce8260417","lab_id":"69ad52a3de79e566650fba9f","country":"PL","accr_number":"AB 1939","accr_body":"PCA","test_object":"Wyroby tytoniowe: Płyn nikotynowy do papierosów elektronicznych","test_object_en":"Tobacco products: Nicotine liquid for electronic cigarettes","methodology":"Zawartość nikotyny","methodology_en":"Nicotine content","parameters":[{"name":"Zakres","range":"(0,16 – 16,00) %"}],"parameters_en":[{"name":"Range","range":"(0,16 – 16,00) %"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Zawartość nikotyny\nZakres (0,16 – 16,00) %\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"EFH_QA_WI_24 wersja 9 z dnia 05.05.2025","norm_bases":["EFH_QA_WI_24 wersja 9 z dnia 05.05.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby tytoniowe: Płyn nikotynowy do papierosów elektronicznych Zawartość nikotyny\nZakres (0,16 – 16,00) %\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) EFH_QA_WI_24 wersja 9 z dnia 05.05.2025 Wyroby tytoniowe: Plyn nikotynowy do papierosow elektronicznych Zawartosc nikotyny\nZakres (0,16 – 16,00) %\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) EFH_QA_WI_24 wersja 9 z dnia 05.05.2025","categories":["electronics"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"尼古丁含量","parameters_zh":[{"name":"范围","range":"(0,16 – 16,00) %"}],"search_zh":"烟草制品：电子烟用尼古丁烟液 尼古丁含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 EFH_QA_WI_24 wersja 9 z dnia 05.05.2025","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"烟草制品：电子烟用尼古丁烟液","search_en":"Tobacco products: Nicotine liquid for electronic cigarettes Nicotine content Gas chromatography with flame ionization detection (GC-FID) Range EFH_QA_WI_24 wersja 9 z dnia 05.05.2025"},{"_id":"6a5dc9c5f1c10c8ce8260418","lab_id":"69ad52a3de79e566650fba9f","country":"PL","accr_number":"AB 1939","accr_body":"PCA","test_object":"Wyroby tytoniowe: Płyn nikotynowy do papierosów elektronicznych","test_object_en":"Tobacco products: Nicotine liquid for electronic cigarettes","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,00 – 11,00"}],"parameters_en":[{"name":"Range","range":"4,00 – 11,00"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,00 – 11,00\nMetoda potencjometryczna","reference":"EFH_QA_WI_10 wersja 12 z dnia 05.05.2025","norm_bases":["EFH_QA_WI_10 wersja 12 z dnia 05.05.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby tytoniowe: Płyn nikotynowy do papierosów elektronicznych pH\nZakres 4,00 – 11,00\nMetoda potencjometryczna EFH_QA_WI_10 wersja 12 z dnia 05.05.2025 Wyroby tytoniowe: Plyn nikotynowy do papierosow elektronicznych pH\nZakres 4,00 – 11,00\nMetoda potencjometryczna EFH_QA_WI_10 wersja 12 z dnia 05.05.2025","categories":["electronics"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,00 – 11,00"}],"search_zh":"烟草制品：电子烟用尼古丁烟液 pH 值 电位法 范围 EFH_QA_WI_10 wersja 12 z dnia 05.05.2025","technique_zh":"电位法","test_object_zh":"烟草制品：电子烟用尼古丁烟液","search_en":"Tobacco products: Nicotine liquid for electronic cigarettes pH Potentiometric method Range EFH_QA_WI_10 wersja 12 z dnia 05.05.2025"},{"_id":"6a5dc9c5f1c10c8ce8260419","lab_id":"69ad52a3de79e566650fba9f","country":"PL","accr_number":"AB 1939","accr_body":"PCA","test_object":"Wyroby tytoniowe: Płyn nikotynowy do papierosów elektronicznych","test_object_en":"Tobacco products: Nicotine liquid for electronic cigarettes","methodology":"Gęstość","methodology_en":"Density","parameters":[{"name":"Zakres","range":"(0,9982 – 1,2834) g/cm3"}],"parameters_en":[{"name":"Range","range":"(0,9982 – 1,2834) g/cm3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"technique_en":"Oscillation method","computed":[],"computed_en":[],"activity":"Gęstość\nZakres (0,9982 – 1,2834) g/cm3\nMetoda oscylacyjna","reference":"EFH_QA_WI_3 wersja 13 z dnia 11.04.2025","norm_bases":["EFH_QA_WI_3 wersja 13 z dnia 11.04.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby tytoniowe: Płyn nikotynowy do papierosów elektronicznych Gęstość\nZakres (0,9982 – 1,2834) g/cm3\nMetoda oscylacyjna EFH_QA_WI_3 wersja 13 z dnia 11.04.2025 Wyroby tytoniowe: Plyn nikotynowy do papierosow elektronicznych Gestosc\nZakres (0,9982 – 1,2834) g/cm3\nMetoda oscylacyjna EFH_QA_WI_3 wersja 13 z dnia 11.04.2025","categories":["electronics"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"密度","parameters_zh":[{"name":"范围","range":"(0,9982 – 1,2834) g/cm3"}],"search_zh":"烟草制品：电子烟用尼古丁烟液 密度 振荡法 范围 EFH_QA_WI_3 wersja 13 z dnia 11.04.2025","technique_zh":"振荡法","test_object_zh":"烟草制品：电子烟用尼古丁烟液","search_en":"Tobacco products: Nicotine liquid for electronic cigarettes Density Oscillation method Range EFH_QA_WI_3 wersja 13 z dnia 11.04.2025"},{"_id":"6a5dc9c5f1c10c8ce826041a","lab_id":"69ad52a3de79e566650fba9f","country":"PL","accr_number":"AB 1939","accr_body":"PCA","test_object":"Wyroby tytoniowe: Płyn nikotynowy do papierosów elektronicznych","test_object_en":"Tobacco products: Nicotine liquid for electronic cigarettes","methodology":"Współczynnik załamania światła","methodology_en":"Refractive index","parameters":[{"name":"Zakres","range":"1,3330 – 1,5245"}],"parameters_en":[{"name":"Range","range":"1,3330 – 1,5245"}],"technique":"Metoda refraktometryczna","techniques":["Metoda refraktometryczna"],"technique_en":"Refractometric method","computed":[],"computed_en":[],"activity":"Współczynnik załamania światła\nZakres 1,3330 – 1,5245\nMetoda refraktometryczna","reference":"EFH_QA_WI_3 wersja 13 z dnia 11.04.2025","norm_bases":["EFH_QA_WI_3 wersja 13 z dnia 11.04.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby tytoniowe: Płyn nikotynowy do papierosów elektronicznych Współczynnik załamania światła\nZakres 1,3330 – 1,5245\nMetoda refraktometryczna EFH_QA_WI_3 wersja 13 z dnia 11.04.2025 Wyroby tytoniowe: Plyn nikotynowy do papierosow elektronicznych Wspolczynnik zalamania swiatla\nZakres 1,3330 – 1,5245\nMetoda refraktometryczna EFH_QA_WI_3 wersja 13 z dnia 11.04.2025","categories":["electronics"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"折射率","parameters_zh":[{"name":"范围","range":"1,3330 – 1,5245"}],"search_zh":"烟草制品：电子烟用尼古丁烟液 折射率 折射法 范围 EFH_QA_WI_3 wersja 13 z dnia 11.04.2025","technique_zh":"折射法","test_object_zh":"烟草制品：电子烟用尼古丁烟液","search_en":"Tobacco products: Nicotine liquid for electronic cigarettes Refractive index Refractometric method Range EFH_QA_WI_3 wersja 13 z dnia 11.04.2025"},{"_id":"6a5dc9c5f1c10c8ce826041b","lab_id":"69ad52a3de79e566650fba9f","country":"PL","accr_number":"AB 1939","accr_body":"PCA","test_object":"Wyroby tytoniowe: Płyn nikotynowy do papierosów elektronicznych","test_object_en":"Tobacco products: Nicotine liquid for electronic cigarettes","methodology":"Ciężar właściwy","methodology_en":"Specific gravity","parameters":[{"name":"Zakres","range":"(1,0000 – 1,2857) g/cm3"}],"parameters_en":[{"name":"Range","range":"(1,0000 – 1,2857) g/cm3"}],"technique":"Metoda z obliczeń","techniques":["Metoda z obliczeń"],"technique_en":"Calculation method","computed":[],"computed_en":[],"activity":"Ciężar właściwy\nZakres (1,0000 – 1,2857) g/cm3\nMetoda z obliczeń","reference":"EFH_QA_WI_3 wersja 13 z dnia 11.04.2025","norm_bases":["EFH_QA_WI_3 wersja 13 z dnia 11.04.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby tytoniowe: Płyn nikotynowy do papierosów elektronicznych Ciężar właściwy\nZakres (1,0000 – 1,2857) g/cm3\nMetoda z obliczeń EFH_QA_WI_3 wersja 13 z dnia 11.04.2025 Wyroby tytoniowe: Plyn nikotynowy do papierosow elektronicznych Ciezar wlasciwy\nZakres (1,0000 – 1,2857) g/cm3\nMetoda z obliczen EFH_QA_WI_3 wersja 13 z dnia 11.04.2025","categories":["electronics"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"相对密度","parameters_zh":[{"name":"范围","range":"(1,0000 – 1,2857) g/cm3"}],"search_zh":"烟草制品：电子烟用尼古丁烟液 相对密度 计算法 范围 EFH_QA_WI_3 wersja 13 z dnia 11.04.2025","technique_zh":"计算法","test_object_zh":"烟草制品：电子烟用尼古丁烟液","search_en":"Tobacco products: Nicotine liquid for electronic cigarettes Specific gravity Calculation method Range EFH_QA_WI_3 wersja 13 z dnia 11.04.2025"},{"_id":"6a5dc9c5f1c10c8ce826041c","lab_id":"69ad52a3de79e566650fba9f","country":"PL","accr_number":"AB 1939","accr_body":"PCA","test_object":"Wyroby tytoniowe: Płyn nikotynowy do papierosów elektronicznych","test_object_en":"Tobacco products: Nicotine liquid for electronic cigarettes","methodology":"Zawartość wody","methodology_en":"Water content","parameters":[{"name":"Zakres","range":"(1,0 – 8,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 8,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość wody\nZakres (1,0 – 8,0) %\nMetoda miareczkowa","reference":"EFH_QA_WI_11 wersja 14 z dnia 11.04.2025","norm_bases":["EFH_QA_WI_11 wersja 14 z dnia 11.04.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby tytoniowe: Płyn nikotynowy do papierosów elektronicznych Zawartość wody\nZakres (1,0 – 8,0) %\nMetoda miareczkowa EFH_QA_WI_11 wersja 14 z dnia 11.04.2025 Wyroby tytoniowe: Plyn nikotynowy do papierosow elektronicznych Zawartosc wody\nZakres (1,0 – 8,0) %\nMetoda miareczkowa EFH_QA_WI_11 wersja 14 z dnia 11.04.2025","categories":["water","electronics"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 8,0) %"}],"search_zh":"烟草制品：电子烟用尼古丁烟液 水分含量 滴定法 范围 EFH_QA_WI_11 wersja 14 z dnia 11.04.2025","technique_zh":"滴定法","test_object_zh":"烟草制品：电子烟用尼古丁烟液","search_en":"Tobacco products: Nicotine liquid for electronic cigarettes Water content Titrimetric method Range EFH_QA_WI_11 wersja 14 z dnia 11.04.2025"}],"has_pdf":true}