{"lab":{"_id":"69ad52a3de79e566650fba81","accr_number":"AB 1924","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAWCZE, ul. Strachocińska 124, 51-511 Wrocław","categories":["environment","metrology","construction"],"city":"Wrocław","imported_at":"2026-03-08T10:42:43.265Z","methods_count":21,"name":"SONITUS Sp. z o.o. Sp.k.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1924.pdf"],"scope_summary":"","search_text":"sonitus sp. z o.o. sp.k. laboratorium badawcze, ul. strachocińska 124, 51-511 wrocław environment metrology other construction","status":"active","updated_at":"2026-03-08T14:51:03.210Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:03.210Z","location":{"type":"Point","coordinates":[17.0385,51.1079]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201924,podmiot.html","fields_of_testing":[{"codes":"A/5; A/13","pl":"Badania akustyczne obiektów budowlanych, maszyn i urządzeń","en":"Acoustic tests of building items, machinery and devices,"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne):- środowisko ogólne (czynniki fizyczne - hałas)","en":"Tests concerning environmental engineering (environmental and climatic) of general environment (physical factors - noise)"}],"issue":{"no":"1","date":"07.02.2025"},"parse_date":"2026-07-20T07:09:57.708Z","parse_source":"script-pdfplumber","map_coord":[51.104215,17.150051],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":14,"metrology":8,"construction":7},"category_scores":{"environment":6.76,"metrology":2.21,"construction":1.69},"has_zh":true},"methods":[{"_id":"6a5dc9c5f1c10c8ce8260402","lab_id":"69ad52a3de79e566650fba81","country":"PL","accr_number":"AB 1924","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A","methodology_en":"A-weighted equivalent sound pressure level","parameters":[{"name":"Zakres","range":"(22 - 137) dB"}],"parameters_en":[{"name":"Range","range":"(22 - 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A\nZakres (22 - 137) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (22 - 137) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (22 - 137) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(22 - 137) dB"}],"search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","technique_zh":"直接测量法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a5dc9c5f1c10c8ce8260403","lab_id":"69ad52a3de79e566650fba81","country":"PL","accr_number":"AB 1924","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a5dc9c5f1c10c8ce8260404","lab_id":"69ad52a3de79e566650fba81","country":"PL","accr_number":"AB 1924","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN, Długookresowy średni poziom dźwięku A wyrażony wskaźnikami LD, LW, LN, LDWN","methodology_en":"A-weighted equivalent sound level for the reference time T expressed by the indices LAeqD and LAeqN, Long-term average A-weighted sound level expressed by the indices LD, LW, LN, LDWN","parameters":[],"parameters_en":[],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"technique_en":"Calculation method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN, Długookresowy średni poziom dźwięku A wyrażony wskaźnikami LD, LW, LN, LDWN\nMetoda obliczeniowa","reference":"PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.)","norm_bases":["PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN, Długookresowy średni poziom dźwięku A wyrażony wskaźnikami LD, LW, LN, LDWN\nMetoda obliczeniowa PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.) Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN, Dlugookresowy sredni poziom dzwieku A wyrazony wskaznikami LD, LW, LN, LDWN\nMetoda obliczeniowa PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z pozn. zm.)","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound level for the reference time T expressed by the indices LAeqD and LAeqN, Long-term average A-weighted sound level expressed by the indices LD, LW, LN, LDWN Calculation method PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.)","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 以 LAeqD 与 LAeqN 指标表示的参考时段 T 内 A 计权等效声级；以 LD、LW、LN、LDWN 指标表示的长期平均 A 计权声级 计算法 PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.)","technique_zh":"计算法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声","methodology_zh":"以 LAeqD 与 LAeqN 指标表示的参考时段 T 内 A 计权等效声级；以 LD、LW、LN、LDWN 指标表示的长期平均 A 计权声级"},{"_id":"6a5dc9c5f1c10c8ce8260405","lab_id":"69ad52a3de79e566650fba81","country":"PL","accr_number":"AB 1924","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","test_object_en":"General environment – noise from roads, railway lines, tram lines","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level","parameters":[{"name":"Zakres","range":"(22 - 137) dB"}],"parameters_en":[{"name":"Range","range":"(22 - 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (22 - 137) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19.05.2015 r. z późn. zm.) NMPB-Roads-1996 NFS 31-133. (XPS 31-133) NMPB-Routes-2008 RMR/SRM II Schall 03","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19.05.2015 r. z późn. zm.) NMPB-Roads-1996 NFS 31-133. (XPS 31-133) NMPB-Routes-2008 RMR/SRM II Schall 03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (22 - 137) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19.05.2015 r. z późn. zm.) NMPB-Roads-1996 NFS 31-133. (XPS 31-133) NMPB-Routes-2008 RMR/SRM II Schall 03 Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A\nZakres (22 - 137) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19.05.2015 r. z pozn. zm.) NMPB-Roads-1996 NFS 31-133. (XPS 31-133) NMPB-Routes-2008 RMR/SRM II Schall 03","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level Direct measurement method Range Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19.05.2015 r. z późn. zm.) NMPB-Roads-1996 NFS 31-133. (XPS 31-133) NMPB-Routes-2008 RMR/SRM II Schall 03","parameters_zh":[{"name":"范围","range":"(22 - 137) dB"}],"search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 A 计权等效声级 A 计权声暴露级 直接测量法 范围 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19.05.2015 r. z późn. zm.) NMPB-Roads-1996 NFS 31-133. (XPS 31-133) NMPB-Routes-2008 RMR/SRM II Schall 03","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声","methodology_zh":"A 计权等效声级 A 计权声暴露级"},{"_id":"6a5dc9c5f1c10c8ce8260406","lab_id":"69ad52a3de79e566650fba81","country":"PL","accr_number":"AB 1924","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","test_object_en":"General environment – noise from roads, railway lines, tram lines","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19.05.2015 r. z późn. zm.) NMPB-Roads-1996 NFS 31-133. (XPS 31-133) NMPB-Routes-2008 RMR/SRM II Schall 03","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19.05.2015 r. z późn. zm.) NMPB-Roads-1996 NFS 31-133. (XPS 31-133) NMPB-Routes-2008 RMR/SRM II Schall 03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19.05.2015 r. z późn. zm.) NMPB-Roads-1996 NFS 31-133. (XPS 31-133) NMPB-Routes-2008 RMR/SRM II Schall 03 Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19.05.2015 r. z pozn. zm.) NMPB-Roads-1996 NFS 31-133. (XPS 31-133) NMPB-Routes-2008 RMR/SRM II Schall 03","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19.05.2015 r. z późn. zm.) NMPB-Roads-1996 NFS 31-133. (XPS 31-133) NMPB-Routes-2008 RMR/SRM II Schall 03","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19.05.2015 r. z późn. zm.) NMPB-Roads-1996 NFS 31-133. (XPS 31-133) NMPB-Routes-2008 RMR/SRM II Schall 03","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a5dc9c5f1c10c8ce8260407","lab_id":"69ad52a3de79e566650fba81","country":"PL","accr_number":"AB 1924","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","test_object_en":"General environment – noise from roads, railway lines, tram lines","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN, Długookresowy średni poziom dźwięku A wyrażony wskaźnikami LD,","methodology_en":"A-weighted equivalent sound level for the reference time T expressed by the indicators LAeqD and LAeqN, Long-term average A-weighted sound level expressed by the indicators LD,","parameters":[],"parameters_en":[],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"technique_en":"Calculation method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN, Długookresowy średni poziom dźwięku A wyrażony wskaźnikami LD,\nMetoda obliczeniowa","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19.05.2015 r. z późn. zm.) NMPB-Roads-1996 NFS 31-133. (XPS 31-133) NMPB-Routes-2008 RMR/SRM II Schall 03","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19.05.2015 r. z późn. zm.) NMPB-Roads-1996 NFS 31-133. (XPS 31-133) NMPB-Routes-2008 RMR/SRM II Schall 03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN, Długookresowy średni poziom dźwięku A wyrażony wskaźnikami LD,\nMetoda obliczeniowa Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19.05.2015 r. z późn. zm.) NMPB-Roads-1996 NFS 31-133. (XPS 31-133) NMPB-Routes-2008 RMR/SRM II Schall 03 Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN, Dlugookresowy sredni poziom dzwieku A wyrazony wskaznikami LD,\nMetoda obliczeniowa Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19.05.2015 r. z pozn. zm.) NMPB-Roads-1996 NFS 31-133. (XPS 31-133) NMPB-Routes-2008 RMR/SRM II Schall 03","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – noise from roads, railway lines, tram lines A-weighted equivalent sound level for the reference time T expressed by the indicators LAeqD and LAeqN, Long-term average A-weighted sound level expressed by the indicators LD, Calculation method Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19.05.2015 r. z późn. zm.) NMPB-Roads-1996 NFS 31-133. (XPS 31-133) NMPB-Routes-2008 RMR/SRM II Schall 03","search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 计算法 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. nr 140, poz. 824 i nr 288, poz. 1697) CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19.05.2015 r. z późn. zm.) NMPB-Roads-1996 NFS 31-133. (XPS 31-133) NMPB-Routes-2008 RMR/SRM II Schall 03","technique_zh":"计算法","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a5dc9c5f1c10c8ce8260408","lab_id":"69ad52a3de79e566650fba81","country":"PL","accr_number":"AB 1924","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas","test_object_en":"Machinery and equipment – noise","methodology":"Poziom ciśnienia akustycznego","methodology_en":"Sound pressure level","parameters":[{"name":"skorygowany charakterystyką"},{"name":"częstotliwościową A Poziom ciśnienia akustycznego"},{"name":"pojedynczego zdarzenia"},{"name":"skorygowany charakterystyką"},{"name":"częstotliwościową A"},{"name":"Zakres","range":"(22 – 137) dB"}],"parameters_en":[{"name":"weighted with the characteristic"},{"name":"A-weighted Sound pressure level"},{"name":"of a single event"},{"name":"weighted with the characteristic"},{"name":"frequency weighting A"},{"name":"Range","range":"(22 – 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Poziom ciśnienia akustycznego\nZakres:\nskorygowany charakterystyką\nczęstotliwościową A Poziom ciśnienia akustycznego\npojedynczego zdarzenia\nskorygowany charakterystyką\nczęstotliwościową A\nZakres (22 – 137) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","norm_bases":["PN-EN ISO 3746:2011","PN-EN ISO 3746:2011/Ap1:2017-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia – hałas Poziom ciśnienia akustycznego\nZakres:\nskorygowany charakterystyką\nczęstotliwościową A Poziom ciśnienia akustycznego\npojedynczego zdarzenia\nskorygowany charakterystyką\nczęstotliwościową A\nZakres (22 – 137) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 Maszyny i urzadzenia – halas Poziom cisnienia akustycznego\nZakres:\nskorygowany charakterystyka\nczestotliwosciowa A Poziom cisnienia akustycznego\npojedynczego zdarzenia\nskorygowany charakterystyka\nczestotliwosciowa A\nZakres (22 – 137) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Machinery and equipment – noise Sound pressure level Direct measurement method weighted with the characteristic A-weighted Sound pressure level of a single event weighted with the characteristic frequency weighting A Range PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","parameters_zh":[{"name":"按特性计权"},{"name":"częstotliwościową A Poziom ciśnienia akustycznego"},{"name":"pojedynczego zdarzenia"},{"name":"按特性计权"},{"name":"A 计权"},{"name":"范围","range":"(22 – 137) dB"}],"search_zh":"机器与设备 – 噪声 声压级 直接测量法 按特性计权 按特性计权 A 计权 范围 PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","technique_zh":"直接测量法","test_object_zh":"机器与设备 – 噪声","methodology_zh":"声压级"},{"_id":"6a5dc9c5f1c10c8ce8260409","lab_id":"69ad52a3de79e566650fba81","country":"PL","accr_number":"AB 1924","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas","test_object_en":"Machinery and equipment – noise","methodology":"Poziom mocy akustycznej (z obliczeń)","methodology_en":"Sound power level (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom mocy akustycznej (z obliczeń)","reference":"PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","norm_bases":["PN-EN ISO 3746:2011","PN-EN ISO 3746:2011/Ap1:2017-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia – hałas Poziom mocy akustycznej (z obliczeń) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 Maszyny i urzadzenia – halas Poziom mocy akustycznej (z obliczen) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Machinery and equipment – noise Sound power level (calculated) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","search_zh":"机器与设备 – 噪声 声功率级（计算值） PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","test_object_zh":"机器与设备 – 噪声","methodology_zh":"声功率级（计算值）"},{"_id":"6a5dc9c5f1c10c8ce826040a","lab_id":"69ad52a3de79e566650fba81","country":"PL","accr_number":"AB 1924","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters":[{"name":"Zakres","range":"(22 – 135) dB"}],"parameters_en":[{"name":"Range","range":"(22 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (22 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-87/B-02156","norm_bases":["PN-87/B-02156"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (22 – 135) dB\nMetoda pomiarowa bezpośrednia PN-87/B-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres (22 – 135) dB\nMetoda pomiarowa bezposrednia PN-87/B-02156","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range PN-87/B-02156","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(22 – 135) dB"}],"search_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 PN-87/B-02156","technique_zh":"直接测量法","test_object_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声"},{"_id":"6a5dc9c5f1c10c8ce826040b","lab_id":"69ad52a3de79e566650fba81","country":"PL","accr_number":"AB 1924","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","methodology_en":"A-weighted equivalent sound level for reference time T (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","reference":"PN-87/B-02156","norm_bases":["PN-87/B-02156"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń) PN-87/B-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas Rownowazny poziom dzwieku A dla czasu odniesienia T (z obliczen) PN-87/B-02156","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level for reference time T (calculated) PN-87/B-02156","methodology_zh":"参考时间 T 内的 A 计权等效声级（计算得出）","search_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声 参考时间 T 内的 A 计权等效声级（计算得出） PN-87/B-02156","test_object_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声"},{"_id":"6a5dc9c5f1c10c8ce826040c","lab_id":"69ad52a3de79e566650fba81","country":"PL","accr_number":"AB 1924","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od urządzeń wyposażenia technicznego przenikający do pomieszczeń","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms","methodology":"Równoważny poziom dźwięku A, Maksymalny poziom dźwięku A,","methodology_en":"A-weighted equivalent sound level, Maximum A-weighted sound level,","parameters":[{"name":"Zakres","range":"(22 – 135) dB"},{"name":"Poziom ciśnienia akustycznego w pasmach 1/1 oktawowych Zakres częstotliwości środkowych:","range":"(31,5 – 8 000 Hz)"}],"parameters_en":[{"name":"Range","range":"(22 – 135) dB"},{"name":"Sound pressure level in 1/1 octave bands Centre frequency range:","range":"(31,5 – 8 000 Hz)"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A, Maksymalny poziom dźwięku A,\nZakres:\nZakres (22 – 135) dB\nPoziom ciśnienia akustycznego w pasmach 1/1 oktawowych Zakres częstotliwości środkowych: (31,5 – 8 000 Hz)\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 16032:2006","norm_bases":["PN-EN ISO 16032:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od urządzeń wyposażenia technicznego przenikający do pomieszczeń Równoważny poziom dźwięku A, Maksymalny poziom dźwięku A,\nZakres:\nZakres (22 – 135) dB\nPoziom ciśnienia akustycznego w pasmach 1/1 oktawowych Zakres częstotliwości środkowych: (31,5 – 8 000 Hz)\nMetoda pomiarowa bezpośrednia PN-EN ISO 16032:2006 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas pochodzacy od urzadzen wyposazenia technicznego przenikajacy do pomieszczen Rownowazny poziom dzwieku A, Maksymalny poziom dzwieku A,\nZakres:\nZakres (22 – 135) dB\nPoziom cisnienia akustycznego w pasmach 1/1 oktawowych Zakres czestotliwosci srodkowych: (31,5 – 8 000 Hz)\nMetoda pomiarowa bezposrednia PN-EN ISO 16032:2006","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms A-weighted equivalent sound level, Maximum A-weighted sound level, Direct measurement method Range Sound pressure level in 1/1 octave bands Centre frequency range: PN-EN ISO 16032:2006","parameters_zh":[{"name":"范围","range":"(22 – 135) dB"},{"name":"Poziom ciśnienia akustycznego w pasmach 1/1 oktawowych Zakres częstotliwości środkowych:","range":"(31,5 – 8 000 Hz)"}],"search_zh":"住宅、集体居住与公共建筑内的房间 － 由技术设备装置产生并传入室内的噪声 A 计权等效声级、A 计权最大声级， 直接测量法 范围 PN-EN ISO 16032:2006","technique_zh":"直接测量法","test_object_zh":"住宅、集体居住与公共建筑内的房间 － 由技术设备装置产生并传入室内的噪声","methodology_zh":"A 计权等效声级、A 计权最大声级，"},{"_id":"6a5dc9c5f1c10c8ce826040d","lab_id":"69ad52a3de79e566650fba81","country":"PL","accr_number":"AB 1924","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od urządzeń wyposażenia technicznego przenikający do pomieszczeń","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms","methodology":"Wzorcowy równoważny poziom dźwięku A,dla cyklu pracy, Wzorcowy maksymalny poziom dźwięku A, dla cyklu pracy (z obliczeń)","methodology_en":"Reference equivalent A sound level,for the operating cycle, Reference maximum A sound level, for the operating cycle (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wzorcowy równoważny poziom dźwięku A,dla cyklu pracy, Wzorcowy maksymalny poziom dźwięku A, dla cyklu pracy (z obliczeń)","reference":"PN-EN ISO 16032:2006","norm_bases":["PN-EN ISO 16032:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od urządzeń wyposażenia technicznego przenikający do pomieszczeń Wzorcowy równoważny poziom dźwięku A,dla cyklu pracy, Wzorcowy maksymalny poziom dźwięku A, dla cyklu pracy (z obliczeń) PN-EN ISO 16032:2006 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas pochodzacy od urzadzen wyposazenia technicznego przenikajacy do pomieszczen Wzorcowy rownowazny poziom dzwieku A,dla cyklu pracy, Wzorcowy maksymalny poziom dzwieku A, dla cyklu pracy (z obliczen) PN-EN ISO 16032:2006","categories":["environment","metrology"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms Reference equivalent A sound level,for the operating cycle, Reference maximum A sound level, for the operating cycle (calculated) PN-EN ISO 16032:2006","search_zh":"住宅、集体居住与公共建筑内的房间 － 由技术设备装置产生并传入室内的噪声 PN-EN ISO 16032:2006","test_object_zh":"住宅、集体居住与公共建筑内的房间 － 由技术设备装置产生并传入室内的噪声"},{"_id":"6a5dc9c5f1c10c8ce826040e","lab_id":"69ad52a3de79e566650fba81","country":"PL","accr_number":"AB 1924","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od urządzeń wyposażenia technicznego przenikający do pomieszczeń","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters":[{"name":"Zakres","range":"(22 – 135) dB"}],"parameters_en":[{"name":"Range","range":"(22 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (22 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/ A1:2010 | PN-EN ISO 10052:2021-12","norm_bases":["PN-EN ISO 10052:2007","PN-EN ISO 10052:2007/ A1:2010","PN-EN ISO 10052:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od urządzeń wyposażenia technicznego przenikający do pomieszczeń Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (22 – 135) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/ A1:2010 | PN-EN ISO 10052:2021-12 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas pochodzacy od urzadzen wyposazenia technicznego przenikajacy do pomieszczen Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres (22 – 135) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/ A1:2010 | PN-EN ISO 10052:2021-12","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/ A1:2010 | PN-EN ISO 10052:2021-12","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(22 – 135) dB"}],"search_zh":"住宅、集体居住与公共建筑内的房间 － 由技术设备装置产生并传入室内的噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/ A1:2010 | PN-EN ISO 10052:2021-12","technique_zh":"直接测量法","test_object_zh":"住宅、集体居住与公共建筑内的房间 － 由技术设备装置产生并传入室内的噪声"},{"_id":"6a5dc9c5f1c10c8ce826040f","lab_id":"69ad52a3de79e566650fba81","country":"PL","accr_number":"AB 1924","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od urządzeń wyposażenia technicznego przenikający do pomieszczeń","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms","methodology":"Wzorcowy równoważny poziom dźwięku A, dla cyklu pracy, Wzorcowy maksymalny poziom dźwięku A, dla cyklu pracy (z obliczeń)","methodology_en":"Reference equivalent A sound level, for the operating cycle, Reference maximum A sound level, for the operating cycle (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wzorcowy równoważny poziom dźwięku A, dla cyklu pracy, Wzorcowy maksymalny poziom dźwięku A, dla cyklu pracy (z obliczeń)","reference":"PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/ A1:2010 | PN-EN ISO 10052:2021-12","norm_bases":["PN-EN ISO 10052:2007","PN-EN ISO 10052:2007/ A1:2010","PN-EN ISO 10052:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od urządzeń wyposażenia technicznego przenikający do pomieszczeń Wzorcowy równoważny poziom dźwięku A, dla cyklu pracy, Wzorcowy maksymalny poziom dźwięku A, dla cyklu pracy (z obliczeń) PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/ A1:2010 | PN-EN ISO 10052:2021-12 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas pochodzacy od urzadzen wyposazenia technicznego przenikajacy do pomieszczen Wzorcowy rownowazny poziom dzwieku A, dla cyklu pracy, Wzorcowy maksymalny poziom dzwieku A, dla cyklu pracy (z obliczen) PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/ A1:2010 | PN-EN ISO 10052:2021-12","categories":["environment","metrology"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rooms in residential, collective residence and public utility buildings – noise from technical equipment penetrating into the rooms Reference equivalent A sound level, for the operating cycle, Reference maximum A sound level, for the operating cycle (calculated) PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/ A1:2010 | PN-EN ISO 10052:2021-12","search_zh":"住宅、集体居住与公共建筑内的房间 － 由技术设备装置产生并传入室内的噪声 PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/ A1:2010 | PN-EN ISO 10052:2021-12","test_object_zh":"住宅、集体居住与公共建筑内的房间 － 由技术设备装置产生并传入室内的噪声"},{"_id":"6a5dc9c5f1c10c8ce8260410","lab_id":"69ad52a3de79e566650fba81","country":"PL","accr_number":"AB 1924","accr_body":"PCA","test_object":"Obiekty budowlane","test_object_en":"Construction works","methodology":"Izolacyjność akustyczna właściwa przybliżona R’ i/lub wzorcowa różnica poziomów DnT w pasmach oktawowych i/lub 1/3 oktawowych","methodology_en":"Apparent sound reduction index R’ and/or standardized level difference DnT in octave and/or 1/3 octave bands","parameters":[{"name":"Zakres częstotliwości środkowych"},{"name":"pasm","range":"(100 – 5 000) Hz"}],"parameters_en":[{"name":"Range of centre frequencies"},{"name":"bands","range":"(100 – 5 000) Hz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Izolacyjność akustyczna właściwa przybliżona R’ i/lub wzorcowa różnica poziomów DnT w pasmach oktawowych i/lub 1/3 oktawowych\nZakres:\nZakres częstotliwości środkowych\npasm (100 – 5 000) Hz","reference":"PN-EN ISO 140-4:2000 | PN-EN ISO 16283-1:2014-05 z wyłączeniem p. 7.4 | PN-EN ISO 16283-1:2014-05 /A1:2018-02 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06","norm_bases":["PN-EN ISO 140-4:2000","PN-EN ISO 16283-1:2014-05 z wyłączeniem p. 7.4","PN-EN ISO 16283-1:2014-05 /A1:2018-02","PN-EN ISO 717-1:1999","PN-EN ISO 717-1:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty budowlane Izolacyjność akustyczna właściwa przybliżona R’ i/lub wzorcowa różnica poziomów DnT w pasmach oktawowych i/lub 1/3 oktawowych\nZakres:\nZakres częstotliwości środkowych\npasm (100 – 5 000) Hz PN-EN ISO 140-4:2000 | PN-EN ISO 16283-1:2014-05 z wyłączeniem p. 7.4 | PN-EN ISO 16283-1:2014-05 /A1:2018-02 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06 Obiekty budowlane Izolacyjnosc akustyczna wlasciwa przyblizona R’ i/lub wzorcowa roznica poziomow DnT w pasmach oktawowych i/lub 1/3 oktawowych\nZakres:\nZakres czestotliwosci srodkowych\npasm (100 – 5 000) Hz PN-EN ISO 140-4:2000 | PN-EN ISO 16283-1:2014-05 z wylaczeniem p. 7.4 | PN-EN ISO 16283-1:2014-05 /A1:2018-02 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06","categories":["construction","metrology"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Construction works Apparent sound reduction index R’ and/or standardized level difference DnT in octave and/or 1/3 octave bands Range of centre frequencies bands PN-EN ISO 140-4:2000 | PN-EN ISO 16283-1:2014-05 z wyłączeniem p. 7.4 | PN-EN ISO 16283-1:2014-05 /A1:2018-02 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06","search_zh":"建筑物与构筑物 中心频率范围 频带 PN-EN ISO 140-4:2000 | PN-EN ISO 16283-1:2014-05 z wyłączeniem p. 7.4 | PN-EN ISO 16283-1:2014-05 /A1:2018-02 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06","test_object_zh":"建筑物与构筑物","parameters_zh":[{"name":"中心频率范围"},{"name":"频带","range":"(100 – 5 000) Hz"}]},{"_id":"6a5dc9c5f1c10c8ce8260411","lab_id":"69ad52a3de79e566650fba81","country":"PL","accr_number":"AB 1924","accr_body":"PCA","test_object":"Obiekty budowlane","test_object_en":"Construction works","methodology":"Wskaźnik ważony izolacyjności akustycznej właściwej przybliżonej, R’w, i wskaźnik ważony wzorcowej różnicy poziomów DnT,w, oraz widmowe wskaźniki adaptacyjne C i, Ctr","methodology_en":"Weighted apparent sound reduction index, R’w, and weighted standardized level difference DnT,w, and spectrum adaptation terms C and, Ctr","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik ważony izolacyjności akustycznej właściwej przybliżonej, R’w, i wskaźnik ważony wzorcowej różnicy poziomów DnT,w, oraz widmowe wskaźniki adaptacyjne C i, Ctr","reference":"PN-EN ISO 140-4:2000 | PN-EN ISO 16283-1:2014-05 z wyłączeniem p. 7.4 | PN-EN ISO 16283-1:2014-05 /A1:2018-02 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06","norm_bases":["PN-EN ISO 140-4:2000","PN-EN ISO 16283-1:2014-05 z wyłączeniem p. 7.4","PN-EN ISO 16283-1:2014-05 /A1:2018-02","PN-EN ISO 717-1:1999","PN-EN ISO 717-1:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty budowlane Wskaźnik ważony izolacyjności akustycznej właściwej przybliżonej, R’w, i wskaźnik ważony wzorcowej różnicy poziomów DnT,w, oraz widmowe wskaźniki adaptacyjne C i, Ctr PN-EN ISO 140-4:2000 | PN-EN ISO 16283-1:2014-05 z wyłączeniem p. 7.4 | PN-EN ISO 16283-1:2014-05 /A1:2018-02 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06 Obiekty budowlane Wskaznik wazony izolacyjnosci akustycznej wlasciwej przyblizonej, R’w, i wskaznik wazony wzorcowej roznicy poziomow DnT,w, oraz widmowe wskazniki adaptacyjne C i, Ctr PN-EN ISO 140-4:2000 | PN-EN ISO 16283-1:2014-05 z wylaczeniem p. 7.4 | PN-EN ISO 16283-1:2014-05 /A1:2018-02 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06","categories":["construction","metrology"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Construction works Weighted apparent sound reduction index, R’w, and weighted standardized level difference DnT,w, and spectrum adaptation terms C and, Ctr PN-EN ISO 140-4:2000 | PN-EN ISO 16283-1:2014-05 z wyłączeniem p. 7.4 | PN-EN ISO 16283-1:2014-05 /A1:2018-02 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06","search_zh":"建筑物与构筑物 PN-EN ISO 140-4:2000 | PN-EN ISO 16283-1:2014-05 z wyłączeniem p. 7.4 | PN-EN ISO 16283-1:2014-05 /A1:2018-02 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06","test_object_zh":"建筑物与构筑物"},{"_id":"6a5dc9c5f1c10c8ce8260412","lab_id":"69ad52a3de79e566650fba81","country":"PL","accr_number":"AB 1924","accr_body":"PCA","test_object":"Obiekty budowlane","test_object_en":"Construction works","methodology":"Izolacyjność akustyczna właściwa przybliżona elementu R’45 i/lub wzorcowa różnica poziomów D2m,nT w pasmach oktawowych i/lub 1/3 oktawowych","methodology_en":"Apparent sound reduction index of the element R’45 and/or standardized level difference D2m,nT in octave and/or 1/3 octave bands","parameters":[{"name":"Zakres częstotliwości środkowych"},{"name":"pasm","range":"100 – 5 000) Hz"}],"parameters_en":[{"name":"Range of centre frequencies"},{"name":"bands","range":"100 – 5 000) Hz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Izolacyjność akustyczna właściwa przybliżona elementu R’45 i/lub wzorcowa różnica poziomów D2m,nT w pasmach oktawowych i/lub 1/3 oktawowych\nZakres:\nZakres częstotliwości środkowych\npasm 100 – 5 000) Hz","reference":"PN-EN ISO 140-5:1999 | PN-EN ISO 16283-3:2016-04 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06","norm_bases":["PN-EN ISO 140-5:1999","PN-EN ISO 16283-3:2016-04","PN-EN ISO 717-1:1999","PN-EN ISO 717-1:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty budowlane Izolacyjność akustyczna właściwa przybliżona elementu R’45 i/lub wzorcowa różnica poziomów D2m,nT w pasmach oktawowych i/lub 1/3 oktawowych\nZakres:\nZakres częstotliwości środkowych\npasm 100 – 5 000) Hz PN-EN ISO 140-5:1999 | PN-EN ISO 16283-3:2016-04 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06 Obiekty budowlane Izolacyjnosc akustyczna wlasciwa przyblizona elementu R’45 i/lub wzorcowa roznica poziomow D2m,nT w pasmach oktawowych i/lub 1/3 oktawowych\nZakres:\nZakres czestotliwosci srodkowych\npasm 100 – 5 000) Hz PN-EN ISO 140-5:1999 | PN-EN ISO 16283-3:2016-04 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06","categories":["construction","metrology"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Construction works Apparent sound reduction index of the element R’45 and/or standardized level difference D2m,nT in octave and/or 1/3 octave bands Range of centre frequencies bands PN-EN ISO 140-5:1999 | PN-EN ISO 16283-3:2016-04 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06","search_zh":"建筑物与构筑物 中心频率范围 频带 PN-EN ISO 140-5:1999 | PN-EN ISO 16283-3:2016-04 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06","test_object_zh":"建筑物与构筑物","parameters_zh":[{"name":"中心频率范围"},{"name":"频带","range":"100 – 5 000) Hz"}]},{"_id":"6a5dc9c5f1c10c8ce8260413","lab_id":"69ad52a3de79e566650fba81","country":"PL","accr_number":"AB 1924","accr_body":"PCA","test_object":"Obiekty budowlane","test_object_en":"Construction works","methodology":"Wskaźnik ważony izolacyjności akustycznej właściwej przybliżonej, R’45.w, i wskaźnik ważony wzorcowej różnicy poziomów D2m,nT,w, oraz widmowe wskaźniki adaptacyjne C i, Ctr","methodology_en":"Weighted apparent sound reduction index, R’45.w, and weighted standardized level difference D2m,nT,w, and spectrum adaptation terms C and, Ctr","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik ważony izolacyjności akustycznej właściwej przybliżonej, R’45.w, i wskaźnik ważony wzorcowej różnicy poziomów D2m,nT,w, oraz widmowe wskaźniki adaptacyjne C i, Ctr","reference":"PN-EN ISO 140-5:1999 | PN-EN ISO 16283-3:2016-04 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06","norm_bases":["PN-EN ISO 140-5:1999","PN-EN ISO 16283-3:2016-04","PN-EN ISO 717-1:1999","PN-EN ISO 717-1:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty budowlane Wskaźnik ważony izolacyjności akustycznej właściwej przybliżonej, R’45.w, i wskaźnik ważony wzorcowej różnicy poziomów D2m,nT,w, oraz widmowe wskaźniki adaptacyjne C i, Ctr PN-EN ISO 140-5:1999 | PN-EN ISO 16283-3:2016-04 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06 Obiekty budowlane Wskaznik wazony izolacyjnosci akustycznej wlasciwej przyblizonej, R’45.w, i wskaznik wazony wzorcowej roznicy poziomow D2m,nT,w, oraz widmowe wskazniki adaptacyjne C i, Ctr PN-EN ISO 140-5:1999 | PN-EN ISO 16283-3:2016-04 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06","categories":["construction","metrology"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Construction works Weighted apparent sound reduction index, R’45.w, and weighted standardized level difference D2m,nT,w, and spectrum adaptation terms C and, Ctr PN-EN ISO 140-5:1999 | PN-EN ISO 16283-3:2016-04 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06","search_zh":"建筑物与构筑物 PN-EN ISO 140-5:1999 | PN-EN ISO 16283-3:2016-04 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06","test_object_zh":"建筑物与构筑物"},{"_id":"6a5dc9c5f1c10c8ce8260414","lab_id":"69ad52a3de79e566650fba81","country":"PL","accr_number":"AB 1924","accr_body":"PCA","test_object":"Obiekty budowlane","test_object_en":"Construction works","methodology":"Przybliżony poziom uderzeniowy znormalizowany L’n, i/lub poziom uderzeniowy wzorcowy L’nT w pasmach oktawowych i/lub 1/3 oktawowych","methodology_en":"Approximate normalized impact sound pressure level L’n, and/or standardized impact sound pressure level L’nT in octave and/or 1/3 octave bands","parameters":[{"name":"Zakres częstotliwości środkowych"},{"name":"pasm","range":"(100 – 5 000) Hz"}],"parameters_en":[{"name":"Range of centre frequencies"},{"name":"bands","range":"(100 – 5 000) Hz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Przybliżony poziom uderzeniowy znormalizowany L’n, i/lub poziom uderzeniowy wzorcowy L’nT w pasmach oktawowych i/lub 1/3 oktawowych\nZakres:\nZakres częstotliwości środkowych\npasm (100 – 5 000) Hz","reference":"PN-EN ISO 140-7:2000 | PN-EN ISO 16283-2:2021-02 z wyłączeniem p. 7.2.3 oraz p.7.4 | PN-EN ISO 717-2:1999 | PN-EN ISO 717-2:2021-06","norm_bases":["PN-EN ISO 140-7:2000","PN-EN ISO 16283-2:2021-02 z wyłączeniem p. 7.2.3 oraz p.7.4","PN-EN ISO 717-2:1999","PN-EN ISO 717-2:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty budowlane Przybliżony poziom uderzeniowy znormalizowany L’n, i/lub poziom uderzeniowy wzorcowy L’nT w pasmach oktawowych i/lub 1/3 oktawowych\nZakres:\nZakres częstotliwości środkowych\npasm (100 – 5 000) Hz PN-EN ISO 140-7:2000 | PN-EN ISO 16283-2:2021-02 z wyłączeniem p. 7.2.3 oraz p.7.4 | PN-EN ISO 717-2:1999 | PN-EN ISO 717-2:2021-06 Obiekty budowlane Przyblizony poziom uderzeniowy znormalizowany L’n, i/lub poziom uderzeniowy wzorcowy L’nT w pasmach oktawowych i/lub 1/3 oktawowych\nZakres:\nZakres czestotliwosci srodkowych\npasm (100 – 5 000) Hz PN-EN ISO 140-7:2000 | PN-EN ISO 16283-2:2021-02 z wylaczeniem p. 7.2.3 oraz p.7.4 | PN-EN ISO 717-2:1999 | PN-EN ISO 717-2:2021-06","categories":["construction","metrology"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Construction works Approximate normalized impact sound pressure level L’n, and/or standardized impact sound pressure level L’nT in octave and/or 1/3 octave bands Range of centre frequencies bands PN-EN ISO 140-7:2000 | PN-EN ISO 16283-2:2021-02 z wyłączeniem p. 7.2.3 oraz p.7.4 | PN-EN ISO 717-2:1999 | PN-EN ISO 717-2:2021-06","search_zh":"建筑物与构筑物 中心频率范围 频带 PN-EN ISO 140-7:2000 | PN-EN ISO 16283-2:2021-02 z wyłączeniem p. 7.2.3 oraz p.7.4 | PN-EN ISO 717-2:1999 | PN-EN ISO 717-2:2021-06","test_object_zh":"建筑物与构筑物","parameters_zh":[{"name":"中心频率范围"},{"name":"频带","range":"(100 – 5 000) Hz"}]},{"_id":"6a5dc9c5f1c10c8ce8260415","lab_id":"69ad52a3de79e566650fba81","country":"PL","accr_number":"AB 1924","accr_body":"PCA","test_object":"Obiekty budowlane","test_object_en":"Construction works","methodology":"Wskaźnik ważony przybliżonego poziomu uderzeniowego znormalizowanego L’n,w, i wskaźnik ważony poziomu uderzeniowego wzorcowego L’nT,w oraz widmowy wskaźnik adaptacyjny CI (z obliczeń)","methodology_en":"Weighted apparent normalized impact sound pressure level L’n,w, and weighted standardized impact sound pressure level L’nT,w and spectrum adaptation term CI (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik ważony przybliżonego poziomu uderzeniowego znormalizowanego L’n,w, i wskaźnik ważony poziomu uderzeniowego wzorcowego L’nT,w oraz widmowy wskaźnik adaptacyjny CI (z obliczeń)","reference":"PN-EN ISO 140-7:2000 | PN-EN ISO 16283-2:2021-02 z wyłączeniem p. 7.2.3 oraz p.7.4 | PN-EN ISO 717-2:1999 | PN-EN ISO 717-2:2021-06","norm_bases":["PN-EN ISO 140-7:2000","PN-EN ISO 16283-2:2021-02 z wyłączeniem p. 7.2.3 oraz p.7.4","PN-EN ISO 717-2:1999","PN-EN ISO 717-2:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty budowlane Wskaźnik ważony przybliżonego poziomu uderzeniowego znormalizowanego L’n,w, i wskaźnik ważony poziomu uderzeniowego wzorcowego L’nT,w oraz widmowy wskaźnik adaptacyjny CI (z obliczeń) PN-EN ISO 140-7:2000 | PN-EN ISO 16283-2:2021-02 z wyłączeniem p. 7.2.3 oraz p.7.4 | PN-EN ISO 717-2:1999 | PN-EN ISO 717-2:2021-06 Obiekty budowlane Wskaznik wazony przyblizonego poziomu uderzeniowego znormalizowanego L’n,w, i wskaznik wazony poziomu uderzeniowego wzorcowego L’nT,w oraz widmowy wskaznik adaptacyjny CI (z obliczen) PN-EN ISO 140-7:2000 | PN-EN ISO 16283-2:2021-02 z wylaczeniem p. 7.2.3 oraz p.7.4 | PN-EN ISO 717-2:1999 | PN-EN ISO 717-2:2021-06","categories":["construction","metrology"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Construction works Weighted apparent normalized impact sound pressure level L’n,w, and weighted standardized impact sound pressure level L’nT,w and spectrum adaptation term CI (calculated) PN-EN ISO 140-7:2000 | PN-EN ISO 16283-2:2021-02 z wyłączeniem p. 7.2.3 oraz p.7.4 | PN-EN ISO 717-2:1999 | PN-EN ISO 717-2:2021-06","methodology_zh":"计权表观标准化撞击声压级 L’n,w、计权标准撞击声压级 L’nT,w 以及频谱修正量 CI（计算得出）","search_zh":"建筑物与构筑物 计权表观标准化撞击声压级 L’n,w、计权标准撞击声压级 L’nT,w 以及频谱修正量 CI（计算得出） PN-EN ISO 140-7:2000 | PN-EN ISO 16283-2:2021-02 z wyłączeniem p. 7.2.3 oraz p.7.4 | PN-EN ISO 717-2:1999 | PN-EN ISO 717-2:2021-06","test_object_zh":"建筑物与构筑物"},{"_id":"6a5dc9c5f1c10c8ce8260416","lab_id":"69ad52a3de79e566650fba81","country":"PL","accr_number":"AB 1924","accr_body":"PCA","test_object":"Obiekty budowlane","test_object_en":"Construction works","methodology":"Czas pogłosu w pasmach oktawowych i 1/3-oktawowych","methodology_en":"Reverberation time in octave and 1/3-octave bands","parameters":[],"parameters_en":[],"technique":"Metoda techniczna","techniques":["Metoda techniczna"],"technique_en":"Technical method","computed":[],"computed_en":[],"activity":"Czas pogłosu w pasmach oktawowych i 1/3-oktawowych\nMetoda techniczna","reference":"PN-EN ISO 3382-2:2010","norm_bases":["PN-EN ISO 3382-2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obiekty budowlane Czas pogłosu w pasmach oktawowych i 1/3-oktawowych\nMetoda techniczna PN-EN ISO 3382-2:2010 Obiekty budowlane Czas poglosu w pasmach oktawowych i 1/3-oktawowych\nMetoda techniczna PN-EN ISO 3382-2:2010","categories":["construction"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Construction works Reverberation time in octave and 1/3-octave bands Technical method PN-EN ISO 3382-2:2010","search_zh":"建筑物与构筑物 工程法 PN-EN ISO 3382-2:2010","test_object_zh":"建筑物与构筑物","technique_zh":"工程法"}],"has_pdf":true}