{"lab":{"_id":"69ad52a3de79e566650fba73","accr_number":"AB 1917","country":"PL","accr_body":"PCA","address":"ul. Hipolita Cegielskiego 1, 32-400 Myślenice, ZAKŁAD BYDGOSZCZ, WYDZIAŁ KONTROLI JAKOŚCI, ul. Fordońska 152","categories":["materials","construction","water","petro"],"city":"Myślenice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":9,"name":"TELE-FONIKA KABLE S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1917.pdf"],"scope_summary":"","search_text":"tele-fonika kable s.a. ul. hipolita cegielskiego 1, 32-400 myślenice, zakład bydgoszcz, wydział kontroli jakości, ul. fordońska 152 materials construction pharma electronics other metrology water food","status":"active","updated_at":"2026-03-08T14:51:02.811Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:02.811Z","email_confidence":"high","email_mx":true,"email_source":"https://www.tele-fonika.com/kontakt","fields_of_testing":[{"codes":"E/6","pl":"Badania elektryczne i elektroniczne wyrobów i wyposażenia elektrycznego","en":"Electric and electronic tests of electrical products and equipment","de":"Elektrische und elektronische Prüfungen elektrischer Erzeugnisse und Ausrüstung","zh":"电气产品和设备的电气和电子检测","cs":"Elektrické a elektronické zkoušky elektrických výrobků a zařízení"},{"codes":"J/6","pl":"Badania mechaniczne, badania metalograficzne wyrobów i wyposażenia elektrycznego","en":"Mechanical tests, metallographic tests of electrical products and equipment","de":"Mechanische Prüfungen, metallografische Prüfungen elektrischer Erzeugnisse und Ausrüstung","zh":"电气产品和设备的力学检测、金相检测","cs":"Mechanické zkoušky, metalografické zkoušky elektrických výrobků a zařízení"},{"codes":"N/6","pl":"Badania właściwości fizycznych wyrobów i wyposażenia elektrycznego","en":"Tests of physical properties of electrical products and equipment","de":"Prüfungen physikalischer Eigenschaften elektrischer Erzeugnisse und Ausrüstung","zh":"电气产品和设备的物理性能检测","cs":"Zkoušky fyzikálních vlastností elektrických výrobků a zařízení"}],"issue":{"no":"2","date":"10.10.2025"},"parse_date":"2026-07-20T07:09:31.625Z","parse_source":"script-pdfplumber","map_coord":[49.8368,19.954081],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":4,"materials":3,"construction":3,"water":1,"petro":1},"category_scores":{"other":1.33,"materials":0.75,"construction":0.75,"water":0.08,"petro":0.08},"has_zh":true,"lab_locations":[{"code":null,"name":"TELE-FONIKA KABLE S.A.","street":"ul. Hipolita Cegielskiego 1","postal_code":"32-400","city":"Myślenice","is_hq":true,"address":"ul. Hipolita Cegielskiego 1, 32-400 Myślenice","site":"32-400|hipolitacegielskiego1"},{"code":null,"name":"Zakład Bydgoszcz-Wydział Kontroli Jakości","street":"ul. Fordońska 152","postal_code":"85-752","city":"Bydgoszcz","is_hq":false,"address":"ul. Fordońska 152, 85-752 Bydgoszcz","site":"85-752|fordońska152"}],"locations_extracted_at":"2026-10-21T22:39:22.545Z","lab_locations_en":[{"code":null,"name":"TELE-FONIKA KABLE S.A.","street":"ul. Hipolita Cegielskiego 1","postal_code":"32-400","city":"Myślenice","is_hq":true,"address":"ul. Hipolita Cegielskiego 1, 32-400 Myślenice","site":"32-400|hipolitacegielskiego1"},{"code":null,"name":"Bydgoszcz Plant - Quality Control Department","street":"ul. Fordońska 152","postal_code":"85-752","city":"Bydgoszcz","is_hq":false,"address":"ul. Fordońska 152, 85-752 Bydgoszcz","site":"85-752|fordońska152"}],"has_de":true,"lab_locations_de":[{"code":null,"name":"TELE-FONIKA KABLE S.A.","street":"ul. Hipolita Cegielskiego 1","postal_code":"32-400","city":"Myślenice","is_hq":true,"address":"ul. Hipolita Cegielskiego 1, 32-400 Myślenice","site":"32-400|hipolitacegielskiego1"},{"code":null,"name":"Werk Bydgoszcz-Abteilung Qualitätskontrolle","street":"ul. Fordońska 152","postal_code":"85-752","city":"Bydgoszcz","is_hq":false,"address":"ul. Fordońska 152, 85-752 Bydgoszcz","site":"85-752|fordońska152"}],"lab_locations_zh":[{"code":null,"name":"TELE-FONIKA KABLE S.A.","street":"ul. Hipolita Cegielskiego 1","postal_code":"32-400","city":"Myślenice","is_hq":true,"address":"ul. Hipolita Cegielskiego 1, 32-400 Myślenice","site":"32-400|hipolitacegielskiego1"},{"code":null,"name":"比得哥什工厂 - 质量控制处","street":"ul. Fordońska 152","postal_code":"85-752","city":"Bydgoszcz","is_hq":false,"address":"ul. Fordońska 152, 85-752 Bydgoszcz","site":"85-752|fordońska152"}],"has_cs":true,"pelny_cs":true,"lab_locations_cs":[{"code":null,"name":"TELE-FONIKA KABLE S.A.","street":"ul. Hipolita Cegielskiego 1","postal_code":"32-400","city":"Myślenice","is_hq":true,"address":"ul. Hipolita Cegielskiego 1, 32-400 Myślenice","site":"32-400|hipolitacegielskiego1"},{"code":null,"name":"Závod Bydgoszcz-Oddělení kontroly jakosti","street":"ul. Fordońska 152","postal_code":"85-752","city":"Bydgoszcz","is_hq":false,"address":"ul. Fordońska 152, 85-752 Bydgoszcz","site":"85-752|fordońska152"}]},"methods":[{"_id":"6a5dc9abf1c10c8ce825a4d7","lab_id":"69ad52a3de79e566650fba73","country":"PL","accr_number":"AB 1917","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV","test_object_en":"Cables and cable accessories with Un = (3,6 – 500) kV","methodology":"Wytrzymałość elektryczna izolacji","methodology_en":"Dielectric strength of the insulation","parameters":[{"name":"Napięcie probiercze Up:"},{"name":"przemienne 50 Hz (AC) do Up = 1000 kV"},{"name":"udarowe, piorunowe (LI) do Up = 2400 kV"},{"name":"udarowe, łączeniowe (SI) do Up = 1800 kV"},{"name":"stałe (DC) do Up = 1200 kV"}],"parameters_en":[{"name":"Test voltage Up:"},{"name":"alternating 50 Hz (AC) up to Up = 1000 kV"},{"name":"impulse, lightning (LI) up to Up = 2400 kV"},{"name":"impulse, switching (SI) up to Up = 1800 kV"},{"name":"direct (DC) up to Up = 1200 kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna izolacji\nZakres:\nNapięcie probiercze Up:\nprzemienne 50 Hz (AC) do Up = 1000 kV\nudarowe, piorunowe (LI) do Up = 2400 kV\nudarowe, łączeniowe (SI) do Up = 1800 kV\nstałe (DC) do Up = 1200 kV","reference":"PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2010 | IEC 60229:2008-08 | PN-EN IEC 60230:2018-06 | EN IEC 60230:2018 | IEC 60230:2018 | IEC 60230:2018+AMD1:2021-09 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","norm_bases":["PN-HD 620 S3:2023-04 HD 620 S3:2023","PN-HD 620 S2:2010-04 HD 620 S2:2010","IEC 60502-2:2014-02","IEC 60502-2:2024-05","IEC 60840:2020-05","IEC 60840:2020+AMD1:2023-06","IEC 62067:2022-04","IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021","PN-EN 60060-1:2011","EN 60060-1:2010","IEC 60060-1:2010","PN-EN 60060-2:2011","EN 60060-2:2011","IEC 60060-2:2010","IEC 60229:2008-08","PN-EN IEC 60230:2018-06","EN IEC 60230:2018","IEC 60230:2018","IEC 60230:2018+AMD1:2021-09","PN-HD 605-S3:2020-05 HD 605 S3:2019","PN-HD 605 S2:2008-10 HD 605 S2:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV Wytrzymałość elektryczna izolacji\nZakres:\nNapięcie probiercze Up:\nprzemienne 50 Hz (AC) do Up = 1000 kV\nudarowe, piorunowe (LI) do Up = 2400 kV\nudarowe, łączeniowe (SI) do Up = 1800 kV\nstałe (DC) do Up = 1200 kV PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2010 | IEC 60229:2008-08 | PN-EN IEC 60230:2018-06 | EN IEC 60230:2018 | IEC 60230:2018 | IEC 60230:2018+AMD1:2021-09 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008 Kable i osprzet kablowy o Un = (3,6 – 500) kV Wytrzymalosc elektryczna izolacji\nZakres:\nNapiecie probiercze Up:\nprzemienne 50 Hz (AC) do Up = 1000 kV\nudarowe, piorunowe (LI) do Up = 2400 kV\nudarowe, laczeniowe (SI) do Up = 1800 kV\nstale (DC) do Up = 1200 kV PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2010 | IEC 60229:2008-08 | PN-EN IEC 60230:2018-06 | EN IEC 60230:2018 | IEC 60230:2018 | IEC 60230:2018+AMD1:2021-09 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","categories":["construction"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 – 500) kV Dielectric strength of the insulation Test voltage Up: alternating 50 Hz (AC) up to Up = 1000 kV impulse, lightning (LI) up to Up = 2400 kV impulse, switching (SI) up to Up = 1800 kV direct (DC) up to Up = 1200 kV PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2010 | IEC 60229:2008-08 | PN-EN IEC 60230:2018-06 | EN IEC 60230:2018 | IEC 60230:2018 | IEC 60230:2018+AMD1:2021-09 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","methodology_zh":"绝缘介电强度","search_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件 绝缘介电强度 试验电压 Up： 50 Hz 交流（AC）至 Up = 1000 kV 冲击，雷电冲击（LI）最高 Up = 2400 kV 冲击，操作冲击（SI）最高 Up = 1800 kV 直流（DC）至 Up = 1200 kV PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 2012年4月 CIGRE TB 852 2021年11月 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2010 | IEC 60229:2008-08 | PN-EN IEC 60230:2018-06 | EN IEC 60230:2018 | IEC 60230:2018 | IEC 60230:2018+AMD1:2021-09 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件","methodology_de":"Spannungsfestigkeit der Isolierung","parameters_de":[{"name":"Prüfspannung Up:"},{"name":"Wechselspannung 50 Hz (AC) bis Up = 1000 kV"},{"name":"Stoßspannung, Blitzstoßspannung (LI) bis Up = 2400 kV"},{"name":"Stoßspannung, Schaltstoßspannung (SI) bis Up = 1800 kV"},{"name":"Gleich- (DC) bis Up = 1200 kV"}],"search_de":"Kabel und Kabelgarnituren mit Un = (3,6 – 500) kV Spannungsfestigkeit der Isolierung Prüfspannung Up: Wechselspannung 50 Hz (AC) bis Up = 1000 kV Stoßspannung, Blitzstoßspannung (LI) bis Up = 2400 kV Stoßspannung, Schaltstoßspannung (SI) bis Up = 1800 kV Gleich- (DC) bis Up = 1200 kV PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2010 | IEC 60229:2008-08 | PN-EN IEC 60230:2018-06 | EN IEC 60230:2018 | IEC 60230:2018 | IEC 60230:2018+AMD1:2021-09 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_de":"Kabel und Kabelgarnituren mit Un = (3,6 – 500) kV","parameters_zh":[{"name":"试验电压 Up："},{"name":"50 Hz 交流（AC）至 Up = 1000 kV"},{"name":"冲击，雷电冲击（LI）最高 Up = 2400 kV"},{"name":"冲击，操作冲击（SI）最高 Up = 1800 kV"},{"name":"直流（DC）至 Up = 1200 kV"}],"reference_zh":"PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 2012年4月 CIGRE TB 852 2021年11月 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2010 | IEC 60229:2008-08 | PN-EN IEC 60230:2018-06 | EN IEC 60230:2018 | IEC 60230:2018 | IEC 60230:2018+AMD1:2021-09 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","methodology_cs":"Elektrická pevnost izolace","search_cs":"Kabely a kabelové příslušenství s Un = (3,6 – 500) kV Elektrická pevnost izolace Zkušební napětí Up: střídavé 50 Hz (AC) do Up = 1000 kV impulzní, atmosférické (LI) do Up = 2400 kV impulzní, spínací (SI) do Up = 1800 kV stejnosměrné (DC) do Up = 1200 kV PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 duben 2012 CIGRE TB 852 listopad 2021 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2010 | IEC 60229:2008-08 | PN-EN IEC 60230:2018-06 | EN IEC 60230:2018 | IEC 60230:2018 | IEC 60230:2018+AMD1:2021-09 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_cs":"Kabely a kabelové příslušenství s Un = (3,6 – 500) kV","parameters_cs":[{"name":"Zkušební napětí Up:"},{"name":"střídavé 50 Hz (AC) do Up = 1000 kV"},{"name":"impulzní, atmosférické (LI) do Up = 2400 kV"},{"name":"impulzní, spínací (SI) do Up = 1800 kV"},{"name":"stejnosměrné (DC) do Up = 1200 kV"}],"reference_cs":"PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 duben 2012 CIGRE TB 852 listopad 2021 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2010 | IEC 60229:2008-08 | PN-EN IEC 60230:2018-06 | EN IEC 60230:2018 | IEC 60230:2018 | IEC 60230:2018+AMD1:2021-09 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008"},{"_id":"6a5dc9abf1c10c8ce825a4d8","lab_id":"69ad52a3de79e566650fba73","country":"PL","accr_number":"AB 1917","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV","test_object_en":"Cables and cable accessories with Un = (3,6 – 500) kV","methodology":"Intensywność wyładowań niezupełnych przy napięciu probierczym AC","methodology_en":"Partial discharge intensity at AC test voltage","parameters":[{"name":"Zakres","range":"do Up = 400 kV"}],"parameters_en":[{"name":"Range","range":"up to Up = 400 kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Intensywność wyładowań niezupełnych przy napięciu probierczym AC\nZakres do Up = 400 kV","reference":"PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-EN 60885-3:2015-07 | EN 60885-3:2015 | IEC 60885-3:2015 | PN-EN 60270:2003-04 | EN 60270:2001 | IEC 60270:2025 | PN-EN 60270:2003/A1:2016 | EN 60270:2001/A1:2016 | IEC 60270:2000/A1:2015 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2: 2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","norm_bases":["PN-HD 620 S3:2023-04 HD 620 S3:2023","PN-HD 620 S2:2010-04 HD 620 S2:2010","IEC 60502-2:2014-02","IEC 60502-2:2024-05","IEC 60840:2020-05","IEC 60840:2020+AMD1:2023-06","IEC 62067:2022-04","PN-EN 60885-3:2015-07","EN 60885-3:2015","IEC 60885-3:2015","PN-EN 60270:2003-04","EN 60270:2001","IEC 60270:2025","PN-EN 60270:2003/A1:2016","EN 60270:2001/A1:2016","IEC 60270:2000/A1:2015","PN-EN 60060-1:2011","EN 60060-1:2010","IEC 60060-1:2010","PN-EN 60060-2:2011","EN 60060-2:2011","IEC 60060-2: 2011","PN-HD 605-S3:2020-05 HD 605 S3:2019","PN-HD 605 S2:2008-10 HD 605 S2:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV Intensywność wyładowań niezupełnych przy napięciu probierczym AC\nZakres do Up = 400 kV PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-EN 60885-3:2015-07 | EN 60885-3:2015 | IEC 60885-3:2015 | PN-EN 60270:2003-04 | EN 60270:2001 | IEC 60270:2025 | PN-EN 60270:2003/A1:2016 | EN 60270:2001/A1:2016 | IEC 60270:2000/A1:2015 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2: 2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008 Kable i osprzet kablowy o Un = (3,6 – 500) kV Intensywnosc wyladowan niezupelnych przy napieciu probierczym AC\nZakres do Up = 400 kV PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-EN 60885-3:2015-07 | EN 60885-3:2015 | IEC 60885-3:2015 | PN-EN 60270:2003-04 | EN 60270:2001 | IEC 60270:2025 | PN-EN 60270:2003/A1:2016 | EN 60270:2001/A1:2016 | IEC 60270:2000/A1:2015 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2: 2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 – 500) kV Partial discharge intensity at AC test voltage Range PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-EN 60885-3:2015-07 | EN 60885-3:2015 | IEC 60885-3:2015 | PN-EN 60270:2003-04 | EN 60270:2001 | IEC 60270:2025 | PN-EN 60270:2003/A1:2016 | EN 60270:2001/A1:2016 | IEC 60270:2000/A1:2015 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2: 2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","parameters_zh":[{"name":"范围","range":"至 Up = 400 kV"}],"search_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件 交流试验电压下的局部放电强度 范围 PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-EN 60885-3:2015-07 | EN 60885-3:2015 | IEC 60885-3:2015 | PN-EN 60270:2003-04 | EN 60270:2001 | IEC 60270:2025 | PN-EN 60270:2003/A1:2016 | EN 60270:2001/A1:2016 | IEC 60270:2000/A1:2015 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2: 2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件","methodology_de":"Teilentladungsintensität bei AC-Prüfspannung","parameters_de":[{"name":"Bereich","range":"bis Up = 400 kV"}],"search_de":"Kabel und Kabelgarnituren mit Un = (3,6 – 500) kV Teilentladungsintensität bei AC-Prüfspannung Bereich PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-EN 60885-3:2015-07 | EN 60885-3:2015 | IEC 60885-3:2015 | PN-EN 60270:2003-04 | EN 60270:2001 | IEC 60270:2025 | PN-EN 60270:2003/A1:2016 | EN 60270:2001/A1:2016 | IEC 60270:2000/A1:2015 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2: 2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_de":"Kabel und Kabelgarnituren mit Un = (3,6 – 500) kV","methodology_zh":"交流试验电压下的局部放电强度","parameters_cs":[{"name":"Rozsah","range":"do Up = 400 kV"}],"search_cs":"Kabely a kabelové příslušenství s Un = (3,6 – 500) kV Intenzita částečných výbojů při zkušebním napětí AC Rozsah PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-EN 60885-3:2015-07 | EN 60885-3:2015 | IEC 60885-3:2015 | PN-EN 60270:2003-04 | EN 60270:2001 | IEC 60270:2025 | PN-EN 60270:2003/A1:2016 | EN 60270:2001/A1:2016 | IEC 60270:2000/A1:2015 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2: 2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_cs":"Kabely a kabelové příslušenství s Un = (3,6 – 500) kV","methodology_cs":"Intenzita částečných výbojů při zkušebním napětí AC"},{"_id":"6a5dc9abf1c10c8ce825a4d9","lab_id":"69ad52a3de79e566650fba73","country":"PL","accr_number":"AB 1917","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV","test_object_en":"Cables and cable accessories with Un = (3,6 – 500) kV","methodology":"Odporność na cykle grzewcze","methodology_en":"Resistance to heating cycles","parameters":[{"name":"temperatura do T = 150 °C"}],"parameters_en":[{"name":"temperature up to T = 150 °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na cykle grzewcze\ntemperatura do T = 150 °C","reference":"PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","norm_bases":["PN-HD 620 S3:2023-04 HD 620 S3:2023","PN-HD 620 S2:2010-04 HD 620 S2:2010","IEC 60502-2:2014-02","IEC 60502-2:2024-05","IEC 60840:2020-05","IEC 60840:2020+AMD1:2023-06","IEC 62067:2022-04","PN-HD 605-S3:2020-05 HD 605 S3:2019","PN-HD 605 S2:2008-10 HD 605 S2:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV Odporność na cykle grzewcze\ntemperatura do T = 150 °C PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008 Kable i osprzet kablowy o Un = (3,6 – 500) kV Odpornosc na cykle grzewcze\ntemperatura do T = 150 °C PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 – 500) kV Resistance to heating cycles temperature up to T = 150 °C PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","search_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件 耐加热循环性 温度最高 T = 150 °C PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件","methodology_de":"Beständigkeit gegen Heizzyklen","parameters_de":[{"name":"Temperatur bis T = 150 °C"}],"search_de":"Kabel und Kabelgarnituren mit Un = (3,6 – 500) kV Beständigkeit gegen Heizzyklen Temperatur bis T = 150 °C PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_de":"Kabel und Kabelgarnituren mit Un = (3,6 – 500) kV","methodology_zh":"耐加热循环性","parameters_zh":[{"name":"温度最高 T = 150 °C"}],"search_cs":"Kabely a kabelové příslušenství s Un = (3,6 – 500) kV Odolnost vůči tepelným cyklům teplota do T = 150 °C PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_cs":"Kabely a kabelové příslušenství s Un = (3,6 – 500) kV","methodology_cs":"Odolnost vůči tepelným cyklům","parameters_cs":[{"name":"teplota do T = 150 °C"}]},{"_id":"6a5dc9abf1c10c8ce825a4da","lab_id":"69ad52a3de79e566650fba73","country":"PL","accr_number":"AB 1917","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV","test_object_en":"Cables and cable accessories with Un = (3,6 – 500) kV","methodology":"Pomiary elektryczne","methodology_en":"Electrical measurements","parameters":[{"name":"rezystancja R"},{"name":"pojemność elektryczna C"},{"name":"współczynnik stratności elektrycznej tg δ"}],"parameters_en":[{"name":"resistance R"},{"name":"electrical capacitance C"},{"name":"dielectric dissipation factor tan δ"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pomiary elektryczne\nZakres:\nrezystancja R\npojemność elektryczna C\nwspółczynnik stratności elektrycznej tg δ","reference":"PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021 | IEC 60228:2023-12 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","norm_bases":["PN-HD 620 S3:2023-04 HD 620 S3:2023","PN-HD 620 S2:2010-04 HD 620 S2:2010","IEC 60502-2:2014-02","IEC 60502-2:2024-05","IEC 60840:2020-05","IEC 60840:2020+AMD1:2023-06","IEC 62067:2022-04","IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021","IEC 60228:2023-12","PN-EN 60060-1:2011","EN 60060-1:2010","IEC 60060-1:2010","PN-EN 60060-2:2011","EN 60060-2:2011","IEC 60060-2:2011","PN-HD 605-S3:2020-05 HD 605 S3:2019","PN-HD 605 S2:2008-10 HD 605 S2:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV Pomiary elektryczne\nZakres:\nrezystancja R\npojemność elektryczna C\nwspółczynnik stratności elektrycznej tg δ PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021 | IEC 60228:2023-12 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008 Kable i osprzet kablowy o Un = (3,6 – 500) kV Pomiary elektryczne\nZakres:\nrezystancja R\npojemnosc elektryczna C\nwspolczynnik stratnosci elektrycznej tg δ PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021 | IEC 60228:2023-12 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","categories":["other"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 – 500) kV Electrical measurements resistance R electrical capacitance C dielectric dissipation factor tan δ PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021 | IEC 60228:2023-12 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","search_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件 电气测量 电阻 R 电容 C 介质损耗因数 tg δ PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 2012年4月 CIGRE TB 852 2021年11月 | IEC 60228:2023-12 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件","methodology_de":"Elektrische Messungen","parameters_de":[{"name":"Widerstand R"},{"name":"elektrische Kapazität C"},{"name":"elektrischer Verlustfaktor tg δ"}],"search_de":"Kabel und Kabelgarnituren mit Un = (3,6 – 500) kV Elektrische Messungen Widerstand R elektrische Kapazität C elektrischer Verlustfaktor tg δ PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021 | IEC 60228:2023-12 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_de":"Kabel und Kabelgarnituren mit Un = (3,6 – 500) kV","methodology_zh":"电气测量","parameters_zh":[{"name":"电阻 R"},{"name":"电容 C"},{"name":"介质损耗因数 tg δ"}],"reference_zh":"PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 2012年4月 CIGRE TB 852 2021年11月 | IEC 60228:2023-12 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","search_cs":"Kabely a kabelové příslušenství s Un = (3,6 – 500) kV Elektrická měření odpor R elektrická kapacita C ztrátový činitel tg δ PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 duben 2012 CIGRE TB 852 listopad 2021 | IEC 60228:2023-12 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_cs":"Kabely a kabelové příslušenství s Un = (3,6 – 500) kV","methodology_cs":"Elektrická měření","parameters_cs":[{"name":"odpor R"},{"name":"elektrická kapacita C"},{"name":"ztrátový činitel tg δ"}],"reference_cs":"PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 duben 2012 CIGRE TB 852 listopad 2021 | IEC 60228:2023-12 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008"},{"_id":"6a5dc9abf1c10c8ce825a4db","lab_id":"69ad52a3de79e566650fba73","country":"PL","accr_number":"AB 1917","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV","test_object_en":"Cables and cable accessories with Un = (3,6 – 500) kV","methodology":"Szczelność:","methodology_en":"Tightness:","parameters":[{"name":"temperatura H2O do T = 85 °C"},{"name":"czas próby do t = 60 dni Water penetration:"}],"parameters_en":[{"name":"H2O temperature up to T = 85 °C"},{"name":"test time up to t = 60 days Water penetration:"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność:\nZakres:\ntemperatura H2O do T = 85 °C\nczas próby do t = 60 dni Water penetration:","reference":"PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60230:2018-01 | IEC 60230:2018+AMD1:2021-12 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","norm_bases":["PN-HD 620 S3:2023-04 HD 620 S3:2023","PN-HD 620 S2:2010-04 HD 620 S2:2010","IEC 60502-2:2014-02","IEC 60502-2:2024-05","IEC 60840:2020-05","IEC 60840:2020+AMD1:2023-06","IEC 62067:2022-04","IEC 60230:2018-01","IEC 60230:2018+AMD1:2021-12","PN-HD 605-S3:2020-05 HD 605 S3:2019","PN-HD 605 S2:2008-10 HD 605 S2:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV Szczelność:\nZakres:\ntemperatura H2O do T = 85 °C\nczas próby do t = 60 dni Water penetration: PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60230:2018-01 | IEC 60230:2018+AMD1:2021-12 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008 Kable i osprzet kablowy o Un = (3,6 – 500) kV Szczelnosc:\nZakres:\ntemperatura H2O do T = 85 °C\nczas proby do t = 60 dni Water penetration: PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60230:2018-01 | IEC 60230:2018+AMD1:2021-12 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 – 500) kV Tightness: H2O temperature up to T = 85 °C test time up to t = 60 days Water penetration: PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60230:2018-01 | IEC 60230:2018+AMD1:2021-12 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","search_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件 密封性： H2O 温度最高 T = 85 °C 试验时间至 t = 60 天 渗水： PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60230:2018-01 | IEC 60230:2018+AMD1:2021-12 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件","methodology_de":"Dichtheit:","parameters_de":[{"name":"H2O-Temperatur bis T = 85 °C"},{"name":"Prüfdauer bis t = 60 Tage Wassereindringung:"}],"search_de":"Kabel und Kabelgarnituren mit Un = (3,6 – 500) kV Dichtheit: H2O-Temperatur bis T = 85 °C Prüfdauer bis t = 60 Tage Wassereindringung: PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60230:2018-01 | IEC 60230:2018+AMD1:2021-12 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_de":"Kabel und Kabelgarnituren mit Un = (3,6 – 500) kV","methodology_zh":"密封性：","parameters_zh":[{"name":"H2O 温度最高 T = 85 °C"},{"name":"试验时间至 t = 60 天 渗水："}],"search_cs":"Kabely a kabelové příslušenství s Un = (3,6 – 500) kV Těsnost: teplota H2O do T = 85 °C doba zkoušky do t = 60 dní PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60230:2018-01 | IEC 60230:2018+AMD1:2021-12 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_cs":"Kabely a kabelové příslušenství s Un = (3,6 – 500) kV","methodology_cs":"Těsnost:","parameters_cs":[{"name":"teplota H2O do T = 85 °C"},{"name":"doba zkoušky do t = 60 dní"}]},{"_id":"6a5dc9abf1c10c8ce825a4dc","lab_id":"69ad52a3de79e566650fba73","country":"PL","accr_number":"AB 1917","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV","test_object_en":"Cables and cable accessories with Un = (3,6 – 500) kV","methodology":"Pomiary elektryczne:","methodology_en":"Electrical measurements:","parameters":[{"name":"rezystywność ekranów półprzewodzących"}],"parameters_en":[{"name":"resistivity of semi-conducting screens"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pomiary elektryczne:\nrezystywność ekranów półprzewodzących","reference":"PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","norm_bases":["PN-HD 620 S3:2023-04 HD 620 S3:2023","PN-HD 620 S2:2010-04 HD 620 S2:2010","IEC 60502-2:2014-02","IEC 60502-2:2024-05","IEC 60840:2020-05","IEC 60840:2020+AMD1:2023-06","IEC 62067:2022-04","PN-HD 605-S3:2020-05 HD 605 S3:2019","PN-HD 605 S2:2008-10 HD 605 S2:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV Pomiary elektryczne:\nrezystywność ekranów półprzewodzących PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008 Kable i osprzet kablowy o Un = (3,6 – 500) kV Pomiary elektryczne:\nrezystywnosc ekranow polprzewodzacych PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","categories":["other"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 – 500) kV Electrical measurements: resistivity of semi-conducting screens PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","search_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件 电气测量： 半导电屏蔽电阻率 PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件","methodology_de":"Elektrische Messungen:","parameters_de":[{"name":"spezifischer Widerstand halbleitender Schirme"}],"search_de":"Kabel und Kabelgarnituren mit Un = (3,6 – 500) kV Elektrische Messungen: spezifischer Widerstand halbleitender Schirme PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_de":"Kabel und Kabelgarnituren mit Un = (3,6 – 500) kV","methodology_zh":"电气测量：","parameters_zh":[{"name":"半导电屏蔽电阻率"}],"search_cs":"Kabely a kabelové příslušenství s Un = (3,6 – 500) kV Elektrická měření: rezistivita polovodivých stínění PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_cs":"Kabely a kabelové příslušenství s Un = (3,6 – 500) kV","methodology_cs":"Elektrická měření:","parameters_cs":[{"name":"rezistivita polovodivých stínění"}]},{"_id":"6a5dc9abf1c10c8ce825a4dd","lab_id":"69ad52a3de79e566650fba73","country":"PL","accr_number":"AB 1917","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV","test_object_en":"Cables and cable accessories with Un = (3,6 – 500) kV","methodology":"Sprawdzenia konstrukcji i wymiarów:","methodology_en":"Verification of construction and dimensions:","parameters":[{"name":"budowa żyły roboczej,"},{"name":"grubość materiału izolacyjnego i powłokowego"},{"name":"średnica (na izolacji, ekranach półprzewodzących, ekranie metalicznym, kompletnego kabla)"},{"name":"grubość powłoki metalowej"},{"name":"wymiary drutów i taśm metalowych"},{"name":"wymiary taśm niemetalowych"},{"name":"ułożenie elementów ekranu metalicznego (odstępy między drutami, taśmami, skok drutów, taśm)"},{"name":"oznaczenie (nadruk): kompletność nadrukowanego oznaczenia, czytelność i widoczność, trwałość (jeśli jest wymagana), odstępy i powtarzalność"}],"parameters_en":[{"name":"construction of the working conductor,"},{"name":"thickness of insulating and coating material"},{"name":"diameter (over the insulation, semi-conducting screens, metallic screen, complete cable)"},{"name":"metallic coating thickness"},{"name":"dimensions of metal wires and tapes"},{"name":"dimensions of non-metallic tapes"},{"name":"arrangement of metallic screen elements (spacing between wires, tapes, lay of wires, tapes)"},{"name":"marking (print): completeness of the printed marking, legibility and visibility, durability (if required), spacing and repeatability"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawdzenia konstrukcji i wymiarów:\nZakres:\nbudowa żyły roboczej,\ngrubość materiału izolacyjnego i powłokowego\nśrednica (na izolacji, ekranach półprzewodzących, ekranie metalicznym, kompletnego kabla)\ngrubość powłoki metalowej\nwymiary drutów i taśm metalowych\nwymiary taśm niemetalowych\nułożenie elementów ekranu metalicznego (odstępy między drutami, taśmami, skok drutów, taśm)\noznaczenie (nadruk): kompletność nadrukowanego oznaczenia, czytelność i widoczność, trwałość (jeśli jest wymagana), odstępy i powtarzalność","reference":"PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60228:2023-12 | IEC 60811-201:2012 | IEC 60811-201:2012+AMD1:2017 | IEC 60811-201:2012+AMD2:2023 | IEC 60811-202:2012 | IEC 60811-202:2012+AMD1:2017 | IEC 60811-202:2012+AMD2:2023 | IEC 60811-203:2012 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","norm_bases":["PN-HD 620 S3:2023-04 HD 620 S3:2023","PN-HD 620 S2:2010-04 HD 620 S2:2010","IEC 60502-2:2014-02","IEC 60502-2:2024-05","IEC 60840:2020-05","IEC 60840:2020+AMD1:2023-06","IEC 62067:2022-04","IEC 60228:2023-12","IEC 60811-201:2012","IEC 60811-201:2012+AMD1:2017","IEC 60811-201:2012+AMD2:2023","IEC 60811-202:2012","IEC 60811-202:2012+AMD1:2017","IEC 60811-202:2012+AMD2:2023","IEC 60811-203:2012","PN-HD 605-S3:2020-05 HD 605 S3:2019","PN-HD 605 S2:2008-10 HD 605 S2:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV Sprawdzenia konstrukcji i wymiarów:\nZakres:\nbudowa żyły roboczej,\ngrubość materiału izolacyjnego i powłokowego\nśrednica (na izolacji, ekranach półprzewodzących, ekranie metalicznym, kompletnego kabla)\ngrubość powłoki metalowej\nwymiary drutów i taśm metalowych\nwymiary taśm niemetalowych\nułożenie elementów ekranu metalicznego (odstępy między drutami, taśmami, skok drutów, taśm)\noznaczenie (nadruk): kompletność nadrukowanego oznaczenia, czytelność i widoczność, trwałość (jeśli jest wymagana), odstępy i powtarzalność PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60228:2023-12 | IEC 60811-201:2012 | IEC 60811-201:2012+AMD1:2017 | IEC 60811-201:2012+AMD2:2023 | IEC 60811-202:2012 | IEC 60811-202:2012+AMD1:2017 | IEC 60811-202:2012+AMD2:2023 | IEC 60811-203:2012 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008 Kable i osprzet kablowy o Un = (3,6 – 500) kV Sprawdzenia konstrukcji i wymiarow:\nZakres:\nbudowa zyly roboczej,\ngrubosc materialu izolacyjnego i powlokowego\nsrednica (na izolacji, ekranach polprzewodzacych, ekranie metalicznym, kompletnego kabla)\ngrubosc powloki metalowej\nwymiary drutow i tasm metalowych\nwymiary tasm niemetalowych\nulozenie elementow ekranu metalicznego (odstepy miedzy drutami, tasmami, skok drutow, tasm)\noznaczenie (nadruk): kompletnosc nadrukowanego oznaczenia, czytelnosc i widocznosc, trwalosc (jesli jest wymagana), odstepy i powtarzalnosc PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60228:2023-12 | IEC 60811-201:2012 | IEC 60811-201:2012+AMD1:2017 | IEC 60811-201:2012+AMD2:2023 | IEC 60811-202:2012 | IEC 60811-202:2012+AMD1:2017 | IEC 60811-202:2012+AMD2:2023 | IEC 60811-203:2012 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","categories":["materials","construction"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 – 500) kV Verification of construction and dimensions: construction of the working conductor, thickness of insulating and coating material diameter (over the insulation, semi-conducting screens, metallic screen, complete cable) metallic coating thickness dimensions of metal wires and tapes dimensions of non-metallic tapes arrangement of metallic screen elements (spacing between wires, tapes, lay of wires, tapes) marking (print): completeness of the printed marking, legibility and visibility, durability (if required), spacing and repeatability PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60228:2023-12 | IEC 60811-201:2012 | IEC 60811-201:2012+AMD1:2017 | IEC 60811-201:2012+AMD2:2023 | IEC 60811-202:2012 | IEC 60811-202:2012+AMD1:2017 | IEC 60811-202:2012+AMD2:2023 | IEC 60811-203:2012 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","search_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件 结构和尺寸检查： 工作线芯结构， 绝缘材料和护套材料厚度 直径（绝缘层、半导电屏蔽层、金属屏蔽层、整根电缆上） 金属镀层厚度 金属线和金属带的尺寸 非金属带尺寸 金属屏蔽层元件排列（导线、带材间距，导线、带材节距） 标志（印刷）：印刷标志的完整性、清晰度和可见性、耐久性（如有要求）、间距和重复性 PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60228:2023-12 | IEC 60811-201:2012 | IEC 60811-201:2012+AMD1:2017 | IEC 60811-201:2012+AMD2:2023 | IEC 60811-202:2012 | IEC 60811-202:2012+AMD1:2017 | IEC 60811-202:2012+AMD2:2023 | IEC 60811-203:2012 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件","methodology_de":"Prüfungen von Konstruktion und Abmessungen:","parameters_de":[{"name":"Aufbau des Arbeitsleiters,"},{"name":"Dicke des Isolier- und Mantelwerkstoffs"},{"name":"Durchmesser (über der Isolierung, den Halbleiterschichten, dem Metallschirm, des kompletten Kabels)"},{"name":"Dicke des metallischen Überzugs"},{"name":"Abmessungen von Drähten und Metallbändern"},{"name":"Abmessungen nichtmetallischer Bänder"},{"name":"Anordnung der Elemente des Metallschirms (Abstände zwischen Drähten, Bändern, Schlaglänge der Drähte, Bänder)"},{"name":"Kennzeichnung (Aufdruck): Vollständigkeit der aufgedruckten Kennzeichnung, Lesbarkeit und Sichtbarkeit, Dauerhaftigkeit (falls gefordert), Abstände und Wiederholung"}],"search_de":"Kabel und Kabelgarnituren mit Un = (3,6 – 500) kV Prüfungen von Konstruktion und Abmessungen: Aufbau des Arbeitsleiters, Dicke des Isolier- und Mantelwerkstoffs Durchmesser (über der Isolierung, den Halbleiterschichten, dem Metallschirm, des kompletten Kabels) Dicke des metallischen Überzugs Abmessungen von Drähten und Metallbändern Abmessungen nichtmetallischer Bänder Anordnung der Elemente des Metallschirms (Abstände zwischen Drähten, Bändern, Schlaglänge der Drähte, Bänder) Kennzeichnung (Aufdruck): Vollständigkeit der aufgedruckten Kennzeichnung, Lesbarkeit und Sichtbarkeit, Dauerhaftigkeit (falls gefordert), Abstände und Wiederholung PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60228:2023-12 | IEC 60811-201:2012 | IEC 60811-201:2012+AMD1:2017 | IEC 60811-201:2012+AMD2:2023 | IEC 60811-202:2012 | IEC 60811-202:2012+AMD1:2017 | IEC 60811-202:2012+AMD2:2023 | IEC 60811-203:2012 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_de":"Kabel und Kabelgarnituren mit Un = (3,6 – 500) kV","methodology_zh":"结构和尺寸检查：","parameters_zh":[{"name":"工作线芯结构，"},{"name":"绝缘材料和护套材料厚度"},{"name":"直径（绝缘层、半导电屏蔽层、金属屏蔽层、整根电缆上）"},{"name":"金属镀层厚度"},{"name":"金属线和金属带的尺寸"},{"name":"非金属带尺寸"},{"name":"金属屏蔽层元件排列（导线、带材间距，导线、带材节距）"},{"name":"标志（印刷）：印刷标志的完整性、清晰度和可见性、耐久性（如有要求）、间距和重复性"}],"search_cs":"Kabely a kabelové příslušenství s Un = (3,6 – 500) kV Kontrola konstrukce a rozměrů: konstrukce vodivého jádra, tloušťka izolačního a pláštěového materiálu průměr (na izolaci, polovodivých stíněních, kovovém stínění, kompletního kabelu) tloušťka kovového pláště rozměry kovových drátů a pásků rozměry nekovových pásek uspořádání prvků kovového stínění (rozestupy mezi dráty, pásky, stoupání drátů, pásků) značení (potisk): úplnost potištěného značení, čitelnost a viditelnost, trvanlivost (je-li požadována), rozestupy a opakovatelnost PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60228:2023-12 | IEC 60811-201:2012 | IEC 60811-201:2012+AMD1:2017 | IEC 60811-201:2012+AMD2:2023 | IEC 60811-202:2012 | IEC 60811-202:2012+AMD1:2017 | IEC 60811-202:2012+AMD2:2023 | IEC 60811-203:2012 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_cs":"Kabely a kabelové příslušenství s Un = (3,6 – 500) kV","methodology_cs":"Kontrola konstrukce a rozměrů:","parameters_cs":[{"name":"konstrukce vodivého jádra,"},{"name":"tloušťka izolačního a pláštěového materiálu"},{"name":"průměr (na izolaci, polovodivých stíněních, kovovém stínění, kompletního kabelu)"},{"name":"tloušťka kovového pláště"},{"name":"rozměry kovových drátů a pásků"},{"name":"rozměry nekovových pásek"},{"name":"uspořádání prvků kovového stínění (rozestupy mezi dráty, pásky, stoupání drátů, pásků)"},{"name":"značení (potisk): úplnost potištěného značení, čitelnost a viditelnost, trvanlivost (je-li požadována), rozestupy a opakovatelnost"}]},{"_id":"6a5dc9abf1c10c8ce825a4de","lab_id":"69ad52a3de79e566650fba73","country":"PL","accr_number":"AB 1917","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV","test_object_en":"Cables and cable accessories with Un = (3,6 – 500) kV","methodology":"Sprawdzenie własności fizycznych materiałów","methodology_en":"Verification of the physical properties of materials","parameters":[{"name":"ubytek masy powłoki"},{"name":"nasiąkliwość wodą"},{"name":"gęstość"}],"parameters_en":[{"name":"coating mass loss"},{"name":"water absorption"},{"name":"density"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawdzenie własności fizycznych materiałów\nZakres:\nubytek masy powłoki\nnasiąkliwość wodą\ngęstość","reference":"PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-409:2012 | IEC 60811-402:2012 | IEC 60811-606:2012","norm_bases":["PN-HD 620 S3:2023-04 HD 620 S3:2023","PN-HD 620 S2:2010-04 HD 620 S2:2010","IEC 60502-2:2014-02","IEC 60502-2:2024-05","IEC 60840:2020-05","IEC 60840:2020+AMD1:2023-06","IEC 62067:2022-04","IEC 60811-409:2012","IEC 60811-402:2012","IEC 60811-606:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV Sprawdzenie własności fizycznych materiałów\nZakres:\nubytek masy powłoki\nnasiąkliwość wodą\ngęstość PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-409:2012 | IEC 60811-402:2012 | IEC 60811-606:2012 Kable i osprzet kablowy o Un = (3,6 – 500) kV Sprawdzenie wlasnosci fizycznych materialow\nZakres:\nubytek masy powloki\nnasiakliwosc woda\ngestosc PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-409:2012 | IEC 60811-402:2012 | IEC 60811-606:2012","categories":["materials"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 – 500) kV Verification of the physical properties of materials coating mass loss water absorption density PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-409:2012 | IEC 60811-402:2012 | IEC 60811-606:2012","search_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件 材料物理性能检查 涂层质量损失 吸水率 密度 PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-409:2012 | IEC 60811-402:2012 | IEC 60811-606:2012","test_object_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件","methodology_de":"Prüfung der physikalischen Eigenschaften der Werkstoffe","parameters_de":[{"name":"Massenverlust der Beschichtung"},{"name":"Wasseraufnahme"},{"name":"Dichte"}],"search_de":"Kabel und Kabelgarnituren mit Un = (3,6 – 500) kV Prüfung der physikalischen Eigenschaften der Werkstoffe Massenverlust der Beschichtung Wasseraufnahme Dichte PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-409:2012 | IEC 60811-402:2012 | IEC 60811-606:2012","test_object_de":"Kabel und Kabelgarnituren mit Un = (3,6 – 500) kV","methodology_zh":"材料物理性能检查","parameters_zh":[{"name":"涂层质量损失"},{"name":"吸水率"},{"name":"密度"}],"search_cs":"Kabely a kabelové příslušenství s Un = (3,6 – 500) kV Kontrola fyzikálních vlastností materiálů úbytek hmotnosti pláště nasákavost vodou hustota PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-409:2012 | IEC 60811-402:2012 | IEC 60811-606:2012","test_object_cs":"Kabely a kabelové příslušenství s Un = (3,6 – 500) kV","methodology_cs":"Kontrola fyzikálních vlastností materiálů","parameters_cs":[{"name":"úbytek hmotnosti pláště"},{"name":"nasákavost vodou"},{"name":"hustota"}]},{"_id":"6a5dc9abf1c10c8ce825a4df","lab_id":"69ad52a3de79e566650fba73","country":"PL","accr_number":"AB 1917","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV","test_object_en":"Cables and cable accessories with Un = (3,6 – 500) kV","methodology":"Sprawdzenie własności mechanicznych materiałów:","methodology_en":"Verification of the mechanical properties of materials:","parameters":[{"name":"własności mechaniczne izolacji przed i po starzeniu"},{"name":"własności mechaniczne materiałów po starzeniu próbki kompletnego kabla"},{"name":"odporność na nacisk w podwyższonej temperaturze"},{"name":"odporność na działanie niskiej temperatury"},{"name":"odporność na pęknięcia (heat shock test)"},{"name":"hot set test izolacji"},{"name":"odporność powłoki elastomerowej na działanie oleju"},{"name":"skurcz izolacji"},{"name":"stabilność termiczna"},{"name":"skurcz powłoki"},{"name":"siła odrywania ekranu izolacji"},{"name":"badania elementów kabli z wzdłużnie nałożoną taśmą lub folią metalową, przyklejoną do powłoki zewnętrznej (ocena wizualna, adhezja i wytrzymałość na odrywanie)"}],"parameters_en":[{"name":"mechanical properties of the insulation before and after ageing"},{"name":"mechanical properties of materials after ageing of a complete cable sample"},{"name":"resistance to pressure at elevated temperature"},{"name":"resistance to low temperature"},{"name":"resistance to cracking (heat shock test)"},{"name":"hot set test of insulation"},{"name":"resistance of the elastomeric coating to oil"},{"name":"insulation shrinkage"},{"name":"thermal stability"},{"name":"sheath shrinkage"},{"name":"insulation screen peel force"},{"name":"testing of cable components with a longitudinally applied metal tape or foil bonded to the outer sheath (visual assessment, adhesion and peel strength)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawdzenie własności mechanicznych materiałów:\nZakres:\nwłasności mechaniczne izolacji przed i po starzeniu\nwłasności mechaniczne materiałów po starzeniu próbki kompletnego kabla\nodporność na nacisk w podwyższonej temperaturze\nodporność na działanie niskiej temperatury\nodporność na pęknięcia (heat shock test)\nhot set test izolacji\nodporność powłoki elastomerowej na działanie oleju\nskurcz izolacji\nstabilność termiczna\nskurcz powłoki\nsiła odrywania ekranu izolacji\nbadania elementów kabli z wzdłużnie nałożoną taśmą lub folią metalową, przyklejoną do powłoki zewnętrznej (ocena wizualna, adhezja i wytrzymałość na odrywanie)","reference":"PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-401:2012 | IEC 60811-401:2017 | IEC 60811-501:2012 | IEC 60811-501:2012+AMD1:2018 | IEC 60811-501:2012+AMD2:2023 | IEC 60811-508:2012 | IEC 60811-508:2012+AMD1:2017 | IEC 60811-508:2012+AMD2:2023 | IEC 60811-507:2012 | IEC 60811-505:2012 | IEC 60811-506:2012 | IEC 60811-509:2012 | IEC 60811-509:2012+AMD1:2017 | IEC 60811-404:2012 | IEC 60811-405:2012 | IEC 60811-502:2012 | IEC 60811-503:2012+AMD1:2023 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","norm_bases":["PN-HD 620 S3:2023-04 HD 620 S3:2023","PN-HD 620 S2:2010-04 HD 620 S2:2010","IEC 60502-2:2014-02","IEC 60502-2:2024-05","IEC 60840:2020-05","IEC 60840:2020+AMD1:2023-06","IEC 62067:2022-04","IEC 60811-401:2012","IEC 60811-401:2017","IEC 60811-501:2012","IEC 60811-501:2012+AMD1:2018","IEC 60811-501:2012+AMD2:2023","IEC 60811-508:2012","IEC 60811-508:2012+AMD1:2017","IEC 60811-508:2012+AMD2:2023","IEC 60811-507:2012","IEC 60811-505:2012","IEC 60811-506:2012","IEC 60811-509:2012","IEC 60811-509:2012+AMD1:2017","IEC 60811-404:2012","IEC 60811-405:2012","IEC 60811-502:2012","IEC 60811-503:2012+AMD1:2023","PN-HD 605-S3:2020-05 HD 605 S3:2019","PN-HD 605 S2:2008-10 HD 605 S2:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV Sprawdzenie własności mechanicznych materiałów:\nZakres:\nwłasności mechaniczne izolacji przed i po starzeniu\nwłasności mechaniczne materiałów po starzeniu próbki kompletnego kabla\nodporność na nacisk w podwyższonej temperaturze\nodporność na działanie niskiej temperatury\nodporność na pęknięcia (heat shock test)\nhot set test izolacji\nodporność powłoki elastomerowej na działanie oleju\nskurcz izolacji\nstabilność termiczna\nskurcz powłoki\nsiła odrywania ekranu izolacji\nbadania elementów kabli z wzdłużnie nałożoną taśmą lub folią metalową, przyklejoną do powłoki zewnętrznej (ocena wizualna, adhezja i wytrzymałość na odrywanie) PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-401:2012 | IEC 60811-401:2017 | IEC 60811-501:2012 | IEC 60811-501:2012+AMD1:2018 | IEC 60811-501:2012+AMD2:2023 | IEC 60811-508:2012 | IEC 60811-508:2012+AMD1:2017 | IEC 60811-508:2012+AMD2:2023 | IEC 60811-507:2012 | IEC 60811-505:2012 | IEC 60811-506:2012 | IEC 60811-509:2012 | IEC 60811-509:2012+AMD1:2017 | IEC 60811-404:2012 | IEC 60811-405:2012 | IEC 60811-502:2012 | IEC 60811-503:2012+AMD1:2023 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008 Kable i osprzet kablowy o Un = (3,6 – 500) kV Sprawdzenie wlasnosci mechanicznych materialow:\nZakres:\nwlasnosci mechaniczne izolacji przed i po starzeniu\nwlasnosci mechaniczne materialow po starzeniu probki kompletnego kabla\nodpornosc na nacisk w podwyzszonej temperaturze\nodpornosc na dzialanie niskiej temperatury\nodpornosc na pekniecia (heat shock test)\nhot set test izolacji\nodpornosc powloki elastomerowej na dzialanie oleju\nskurcz izolacji\nstabilnosc termiczna\nskurcz powloki\nsila odrywania ekranu izolacji\nbadania elementow kabli z wzdluznie nalozona tasma lub folia metalowa, przyklejona do powloki zewnetrznej (ocena wizualna, adhezja i wytrzymalosc na odrywanie) PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-401:2012 | IEC 60811-401:2017 | IEC 60811-501:2012 | IEC 60811-501:2012+AMD1:2018 | IEC 60811-501:2012+AMD2:2023 | IEC 60811-508:2012 | IEC 60811-508:2012+AMD1:2017 | IEC 60811-508:2012+AMD2:2023 | IEC 60811-507:2012 | IEC 60811-505:2012 | IEC 60811-506:2012 | IEC 60811-509:2012 | IEC 60811-509:2012+AMD1:2017 | IEC 60811-404:2012 | IEC 60811-405:2012 | IEC 60811-502:2012 | IEC 60811-503:2012+AMD1:2023 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","categories":["materials","petro","construction"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 – 500) kV Verification of the mechanical properties of materials: mechanical properties of the insulation before and after ageing mechanical properties of materials after ageing of a complete cable sample resistance to pressure at elevated temperature resistance to low temperature resistance to cracking (heat shock test) hot set test of insulation resistance of the elastomeric coating to oil insulation shrinkage thermal stability sheath shrinkage insulation screen peel force testing of cable components with a longitudinally applied metal tape or foil bonded to the outer sheath (visual assessment, adhesion and peel strength) PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-401:2012 | IEC 60811-401:2017 | IEC 60811-501:2012 | IEC 60811-501:2012+AMD1:2018 | IEC 60811-501:2012+AMD2:2023 | IEC 60811-508:2012 | IEC 60811-508:2012+AMD1:2017 | IEC 60811-508:2012+AMD2:2023 | IEC 60811-507:2012 | IEC 60811-505:2012 | IEC 60811-506:2012 | IEC 60811-509:2012 | IEC 60811-509:2012+AMD1:2017 | IEC 60811-404:2012 | IEC 60811-405:2012 | IEC 60811-502:2012 | IEC 60811-503:2012+AMD1:2023 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","search_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件 材料力学性能检查： 老化前后绝缘的力学性能 成品电缆试样老化后材料的力学性能 高温下的耐压性 耐低温性 抗开裂性（heat shock test） 绝缘热延伸试验（hot set test） 弹性体涂层耐油性 绝缘收缩 热稳定性 护套收缩 绝缘屏蔽层剥离力 纵包金属带或金属箔并粘结于外护套的电缆元件检测（目视评定、粘附性和剥离强度） PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-401:2012 | IEC 60811-401:2017 | IEC 60811-501:2012 | IEC 60811-501:2012+AMD1:2018 | IEC 60811-501:2012+AMD2:2023 | IEC 60811-508:2012 | IEC 60811-508:2012+AMD1:2017 | IEC 60811-508:2012+AMD2:2023 | IEC 60811-507:2012 | IEC 60811-505:2012 | IEC 60811-506:2012 | IEC 60811-509:2012 | IEC 60811-509:2012+AMD1:2017 | IEC 60811-404:2012 | IEC 60811-405:2012 | IEC 60811-502:2012 | IEC 60811-503:2012+AMD1:2023 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件","methodology_de":"Prüfung der mechanischen Eigenschaften der Werkstoffe:","parameters_de":[{"name":"mechanische Eigenschaften der Isolierung vor und nach Alterung"},{"name":"mechanische Eigenschaften der Werkstoffe nach Alterung einer Probe des vollständigen Kabels"},{"name":"Wärmedruckfestigkeit"},{"name":"Kältebeständigkeit"},{"name":"Rissbeständigkeit (heat shock test)"},{"name":"Wärmedehnungsprüfung (Hot-Set-Test) der Isolierung"},{"name":"Ölbeständigkeit des Elastomermantels"},{"name":"Schrumpfung der Isolierung"},{"name":"thermische Stabilität"},{"name":"Schrumpfung des Mantels"},{"name":"Abziehkraft der äußeren Leitschicht"},{"name":"Prüfungen von Kabelelementen mit längs aufgebrachtem, auf den Außenmantel geklebtem Metallband oder Metallfolie (Sichtprüfung, Haftung und Schälfestigkeit)"}],"search_de":"Kabel und Kabelgarnituren mit Un = (3,6 – 500) kV Prüfung der mechanischen Eigenschaften der Werkstoffe: mechanische Eigenschaften der Isolierung vor und nach Alterung mechanische Eigenschaften der Werkstoffe nach Alterung einer Probe des vollständigen Kabels Wärmedruckfestigkeit Kältebeständigkeit Rissbeständigkeit (heat shock test) Wärmedehnungsprüfung (Hot-Set-Test) der Isolierung Ölbeständigkeit des Elastomermantels Schrumpfung der Isolierung thermische Stabilität Schrumpfung des Mantels Abziehkraft der äußeren Leitschicht Prüfungen von Kabelelementen mit längs aufgebrachtem, auf den Außenmantel geklebtem Metallband oder Metallfolie (Sichtprüfung, Haftung und Schälfestigkeit) PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-401:2012 | IEC 60811-401:2017 | IEC 60811-501:2012 | IEC 60811-501:2012+AMD1:2018 | IEC 60811-501:2012+AMD2:2023 | IEC 60811-508:2012 | IEC 60811-508:2012+AMD1:2017 | IEC 60811-508:2012+AMD2:2023 | IEC 60811-507:2012 | IEC 60811-505:2012 | IEC 60811-506:2012 | IEC 60811-509:2012 | IEC 60811-509:2012+AMD1:2017 | IEC 60811-404:2012 | IEC 60811-405:2012 | IEC 60811-502:2012 | IEC 60811-503:2012+AMD1:2023 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_de":"Kabel und Kabelgarnituren mit Un = (3,6 – 500) kV","methodology_zh":"材料力学性能检查：","parameters_zh":[{"name":"老化前后绝缘的力学性能"},{"name":"成品电缆试样老化后材料的力学性能"},{"name":"高温下的耐压性"},{"name":"耐低温性"},{"name":"抗开裂性（heat shock test）"},{"name":"绝缘热延伸试验（hot set test）"},{"name":"弹性体涂层耐油性"},{"name":"绝缘收缩"},{"name":"热稳定性"},{"name":"护套收缩"},{"name":"绝缘屏蔽层剥离力"},{"name":"纵包金属带或金属箔并粘结于外护套的电缆元件检测（目视评定、粘附性和剥离强度）"}],"search_cs":"Kabely a kabelové příslušenství s Un = (3,6 – 500) kV Kontrola mechanických vlastností materiálů: mechanické vlastnosti izolace před stárnutím a po stárnutí mechanické vlastnosti materiálů po stárnutí vzorku kompletního kabelu odolnost proti tlaku za zvýšené teploty odolnost vůči působení nízké teploty odolnost proti praskání (heat shock test) hot set test izolace odolnost elastomerového pláště vůči působení oleje smrštění izolace tepelná stabilita smrštění pláště odtrhovací síla stínění izolace zkoušky prvků kabelů s podélně uloženou kovovou páskou nebo fólií přilepenou k vnějšímu plášti (vizuální hodnocení, adheze a pevnost v odlupování) PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-401:2012 | IEC 60811-401:2017 | IEC 60811-501:2012 | IEC 60811-501:2012+AMD1:2018 | IEC 60811-501:2012+AMD2:2023 | IEC 60811-508:2012 | IEC 60811-508:2012+AMD1:2017 | IEC 60811-508:2012+AMD2:2023 | IEC 60811-507:2012 | IEC 60811-505:2012 | IEC 60811-506:2012 | IEC 60811-509:2012 | IEC 60811-509:2012+AMD1:2017 | IEC 60811-404:2012 | IEC 60811-405:2012 | IEC 60811-502:2012 | IEC 60811-503:2012+AMD1:2023 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_cs":"Kabely a kabelové příslušenství s Un = (3,6 – 500) kV","methodology_cs":"Kontrola mechanických vlastností materiálů:","parameters_cs":[{"name":"mechanické vlastnosti izolace před stárnutím a po stárnutí"},{"name":"mechanické vlastnosti materiálů po stárnutí vzorku kompletního kabelu"},{"name":"odolnost proti tlaku za zvýšené teploty"},{"name":"odolnost vůči působení nízké teploty"},{"name":"odolnost proti praskání (heat shock test)"},{"name":"hot set test izolace"},{"name":"odolnost elastomerového pláště vůči působení oleje"},{"name":"smrštění izolace"},{"name":"tepelná stabilita"},{"name":"smrštění pláště"},{"name":"odtrhovací síla stínění izolace"},{"name":"zkoušky prvků kabelů s podélně uloženou kovovou páskou nebo fólií přilepenou k vnějšímu plášti (vizuální hodnocení, adheze a pevnost v odlupování)"}]}],"has_pdf":true}