{"lab":{"_id":"69ad52a3de79e566650fba73","accr_number":"AB 1917","country":"PL","accr_body":"PCA","address":"ul. Hipolita Cegielskiego 1, 32-400 Myślenice, ZAKŁAD BYDGOSZCZ, WYDZIAŁ KONTROLI JAKOŚCI, ul. Fordońska 152","categories":["materials","construction","water","petro"],"city":"Myślenice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":9,"name":"TELE-FONIKA KABLE S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1917.pdf"],"scope_summary":"","search_text":"tele-fonika kable s.a. ul. hipolita cegielskiego 1, 32-400 myślenice, zakład bydgoszcz, wydział kontroli jakości, ul. fordońska 152 materials construction pharma electronics other metrology water food","status":"active","updated_at":"2026-03-08T14:51:02.811Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:02.811Z","email_confidence":"high","email_mx":true,"email_source":"https://www.tele-fonika.com/kontakt","fields_of_testing":[{"codes":"E/6","pl":"Badania elektryczne i elektroniczne wyrobów i wyposażenia elektrycznego","en":"Electric and electronic tests of electrical products and equipment"},{"codes":"J/6","pl":"Badania mechaniczne, badania metalograficzne wyrobów i wyposażenia elektrycznego","en":"Mechanical tests, metallographic tests of electrical products and equipment"},{"codes":"N/6","pl":"Badania właściwości fizycznych wyrobów i wyposażenia elektrycznego","en":"Tests of physical properties of electrical products and equipment"}],"issue":{"no":"2","date":"10.10.2025"},"parse_date":"2026-07-20T07:09:31.625Z","parse_source":"script-pdfplumber","map_coord":[49.8368,19.954081],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":4,"materials":3,"construction":3,"water":1,"petro":1},"category_scores":{"other":1.33,"materials":0.75,"construction":0.75,"water":0.08,"petro":0.08},"has_zh":true},"methods":[{"_id":"6a5dc9abf1c10c8ce825a4d7","lab_id":"69ad52a3de79e566650fba73","country":"PL","accr_number":"AB 1917","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV","test_object_en":"Cables and cable accessories with Un = (3,6 – 500) kV","methodology":"Wytrzymałość elektryczna izolacji","methodology_en":"Dielectric strength of the insulation","parameters":[{"name":"Napięcie probiercze Up:"},{"name":"przemienne 50 Hz (AC) do Up = 1000 kV"},{"name":"udarowe, piorunowe (LI) do Up = 2400 kV"},{"name":"udarowe, łączeniowe (SI) do Up = 1800 kV"},{"name":"stałe (DC) do Up = 1200 kV"}],"parameters_en":[{"name":"Test voltage Up:"},{"name":"alternating 50 Hz (AC) up to Up = 1000 kV"},{"name":"impulse, lightning (LI) up to Up = 2400 kV"},{"name":"impulse, switching (SI) up to Up = 1800 kV"},{"name":"direct (DC) up to Up = 1200 kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna izolacji\nZakres:\nNapięcie probiercze Up:\nprzemienne 50 Hz (AC) do Up = 1000 kV\nudarowe, piorunowe (LI) do Up = 2400 kV\nudarowe, łączeniowe (SI) do Up = 1800 kV\nstałe (DC) do Up = 1200 kV","reference":"PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2010 | IEC 60229:2008-08 | PN-EN IEC 60230:2018-06 | EN IEC 60230:2018 | IEC 60230:2018 | IEC 60230:2018+AMD1:2021-09 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","norm_bases":["PN-HD 620 S3:2023-04 HD 620 S3:2023","PN-HD 620 S2:2010-04 HD 620 S2:2010","IEC 60502-2:2014-02","IEC 60502-2:2024-05","IEC 60840:2020-05","IEC 60840:2020+AMD1:2023-06","IEC 62067:2022-04","IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021","PN-EN 60060-1:2011","EN 60060-1:2010","IEC 60060-1:2010","PN-EN 60060-2:2011","EN 60060-2:2011","IEC 60060-2:2010","IEC 60229:2008-08","PN-EN IEC 60230:2018-06","EN IEC 60230:2018","IEC 60230:2018","IEC 60230:2018+AMD1:2021-09","PN-HD 605-S3:2020-05 HD 605 S3:2019","PN-HD 605 S2:2008-10 HD 605 S2:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV Wytrzymałość elektryczna izolacji\nZakres:\nNapięcie probiercze Up:\nprzemienne 50 Hz (AC) do Up = 1000 kV\nudarowe, piorunowe (LI) do Up = 2400 kV\nudarowe, łączeniowe (SI) do Up = 1800 kV\nstałe (DC) do Up = 1200 kV PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2010 | IEC 60229:2008-08 | PN-EN IEC 60230:2018-06 | EN IEC 60230:2018 | IEC 60230:2018 | IEC 60230:2018+AMD1:2021-09 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008 Kable i osprzet kablowy o Un = (3,6 – 500) kV Wytrzymalosc elektryczna izolacji\nZakres:\nNapiecie probiercze Up:\nprzemienne 50 Hz (AC) do Up = 1000 kV\nudarowe, piorunowe (LI) do Up = 2400 kV\nudarowe, laczeniowe (SI) do Up = 1800 kV\nstale (DC) do Up = 1200 kV PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2010 | IEC 60229:2008-08 | PN-EN IEC 60230:2018-06 | EN IEC 60230:2018 | IEC 60230:2018 | IEC 60230:2018+AMD1:2021-09 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","categories":["construction"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 – 500) kV Dielectric strength of the insulation Test voltage Up: alternating 50 Hz (AC) up to Up = 1000 kV impulse, lightning (LI) up to Up = 2400 kV impulse, switching (SI) up to Up = 1800 kV direct (DC) up to Up = 1200 kV PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2010 | IEC 60229:2008-08 | PN-EN IEC 60230:2018-06 | EN IEC 60230:2018 | IEC 60230:2018 | IEC 60230:2018+AMD1:2021-09 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","methodology_zh":"绝缘介电强度","search_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件 绝缘介电强度 PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2010 | IEC 60229:2008-08 | PN-EN IEC 60230:2018-06 | EN IEC 60230:2018 | IEC 60230:2018 | IEC 60230:2018+AMD1:2021-09 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件"},{"_id":"6a5dc9abf1c10c8ce825a4d8","lab_id":"69ad52a3de79e566650fba73","country":"PL","accr_number":"AB 1917","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV","test_object_en":"Cables and cable accessories with Un = (3,6 – 500) kV","methodology":"Intensywność wyładowań niezupełnych przy napięciu probierczym AC","methodology_en":"Partial discharge intensity at AC test voltage","parameters":[{"name":"Zakres","range":"do Up = 400 kV"}],"parameters_en":[{"name":"Range","range":"do Up = 400 kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Intensywność wyładowań niezupełnych przy napięciu probierczym AC\nZakres do Up = 400 kV","reference":"PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-EN 60885-3:2015-07 | EN 60885-3:2015 | IEC 60885-3:2015 | PN-EN 60270:2003-04 | EN 60270:2001 | IEC 60270:2025 | PN-EN 60270:2003/A1:2016 | EN 60270:2001/A1:2016 | IEC 60270:2000/A1:2015 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2: 2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","norm_bases":["PN-HD 620 S3:2023-04 HD 620 S3:2023","PN-HD 620 S2:2010-04 HD 620 S2:2010","IEC 60502-2:2014-02","IEC 60502-2:2024-05","IEC 60840:2020-05","IEC 60840:2020+AMD1:2023-06","IEC 62067:2022-04","PN-EN 60885-3:2015-07","EN 60885-3:2015","IEC 60885-3:2015","PN-EN 60270:2003-04","EN 60270:2001","IEC 60270:2025","PN-EN 60270:2003/A1:2016","EN 60270:2001/A1:2016","IEC 60270:2000/A1:2015","PN-EN 60060-1:2011","EN 60060-1:2010","IEC 60060-1:2010","PN-EN 60060-2:2011","EN 60060-2:2011","IEC 60060-2: 2011","PN-HD 605-S3:2020-05 HD 605 S3:2019","PN-HD 605 S2:2008-10 HD 605 S2:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV Intensywność wyładowań niezupełnych przy napięciu probierczym AC\nZakres do Up = 400 kV PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-EN 60885-3:2015-07 | EN 60885-3:2015 | IEC 60885-3:2015 | PN-EN 60270:2003-04 | EN 60270:2001 | IEC 60270:2025 | PN-EN 60270:2003/A1:2016 | EN 60270:2001/A1:2016 | IEC 60270:2000/A1:2015 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2: 2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008 Kable i osprzet kablowy o Un = (3,6 – 500) kV Intensywnosc wyladowan niezupelnych przy napieciu probierczym AC\nZakres do Up = 400 kV PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-EN 60885-3:2015-07 | EN 60885-3:2015 | IEC 60885-3:2015 | PN-EN 60270:2003-04 | EN 60270:2001 | IEC 60270:2025 | PN-EN 60270:2003/A1:2016 | EN 60270:2001/A1:2016 | IEC 60270:2000/A1:2015 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2: 2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 – 500) kV Partial discharge intensity at AC test voltage Range PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-EN 60885-3:2015-07 | EN 60885-3:2015 | IEC 60885-3:2015 | PN-EN 60270:2003-04 | EN 60270:2001 | IEC 60270:2025 | PN-EN 60270:2003/A1:2016 | EN 60270:2001/A1:2016 | IEC 60270:2000/A1:2015 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2: 2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","parameters_zh":[{"name":"范围","range":"do Up = 400 kV"}],"search_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件 范围 PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-EN 60885-3:2015-07 | EN 60885-3:2015 | IEC 60885-3:2015 | PN-EN 60270:2003-04 | EN 60270:2001 | IEC 60270:2025 | PN-EN 60270:2003/A1:2016 | EN 60270:2001/A1:2016 | IEC 60270:2000/A1:2015 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2: 2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件"},{"_id":"6a5dc9abf1c10c8ce825a4d9","lab_id":"69ad52a3de79e566650fba73","country":"PL","accr_number":"AB 1917","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV","test_object_en":"Cables and cable accessories with Un = (3,6 – 500) kV","methodology":"Odporność na cykle grzewcze","methodology_en":"Resistance to heating cycles","parameters":[{"name":"temperatura do T = 150 °C"}],"parameters_en":[{"name":"temperature up to T = 150 °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na cykle grzewcze\ntemperatura do T = 150 °C","reference":"PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","norm_bases":["PN-HD 620 S3:2023-04 HD 620 S3:2023","PN-HD 620 S2:2010-04 HD 620 S2:2010","IEC 60502-2:2014-02","IEC 60502-2:2024-05","IEC 60840:2020-05","IEC 60840:2020+AMD1:2023-06","IEC 62067:2022-04","PN-HD 605-S3:2020-05 HD 605 S3:2019","PN-HD 605 S2:2008-10 HD 605 S2:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV Odporność na cykle grzewcze\ntemperatura do T = 150 °C PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008 Kable i osprzet kablowy o Un = (3,6 – 500) kV Odpornosc na cykle grzewcze\ntemperatura do T = 150 °C PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 – 500) kV Resistance to heating cycles temperature up to T = 150 °C PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","search_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件 PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件"},{"_id":"6a5dc9abf1c10c8ce825a4da","lab_id":"69ad52a3de79e566650fba73","country":"PL","accr_number":"AB 1917","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV","test_object_en":"Cables and cable accessories with Un = (3,6 – 500) kV","methodology":"Pomiary elektryczne","methodology_en":"Electrical measurements","parameters":[{"name":"rezystancja R"},{"name":"pojemność elektryczna C"},{"name":"współczynnik stratności elektrycznej tg δ"}],"parameters_en":[{"name":"resistance R"},{"name":"electrical capacitance C"},{"name":"dielectric dissipation factor tan δ"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pomiary elektryczne\nZakres:\nrezystancja R\npojemność elektryczna C\nwspółczynnik stratności elektrycznej tg δ","reference":"PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021 | IEC 60228:2023-12 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","norm_bases":["PN-HD 620 S3:2023-04 HD 620 S3:2023","PN-HD 620 S2:2010-04 HD 620 S2:2010","IEC 60502-2:2014-02","IEC 60502-2:2024-05","IEC 60840:2020-05","IEC 60840:2020+AMD1:2023-06","IEC 62067:2022-04","IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021","IEC 60228:2023-12","PN-EN 60060-1:2011","EN 60060-1:2010","IEC 60060-1:2010","PN-EN 60060-2:2011","EN 60060-2:2011","IEC 60060-2:2011","PN-HD 605-S3:2020-05 HD 605 S3:2019","PN-HD 605 S2:2008-10 HD 605 S2:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV Pomiary elektryczne\nZakres:\nrezystancja R\npojemność elektryczna C\nwspółczynnik stratności elektrycznej tg δ PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021 | IEC 60228:2023-12 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008 Kable i osprzet kablowy o Un = (3,6 – 500) kV Pomiary elektryczne\nZakres:\nrezystancja R\npojemnosc elektryczna C\nwspolczynnik stratnosci elektrycznej tg δ PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021 | IEC 60228:2023-12 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","categories":["other"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 – 500) kV Electrical measurements resistance R electrical capacitance C dielectric dissipation factor tan δ PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021 | IEC 60228:2023-12 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","search_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件 PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 62895:2017-05 CIGRE TB 496 April 2012 CIGRE TB 852 November 2021 | IEC 60228:2023-12 | PN-EN 60060-1:2011 | EN 60060-1:2010 | IEC 60060-1:2010 | PN-EN 60060-2:2011 | EN 60060-2:2011 | IEC 60060-2:2011 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件"},{"_id":"6a5dc9abf1c10c8ce825a4db","lab_id":"69ad52a3de79e566650fba73","country":"PL","accr_number":"AB 1917","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV","test_object_en":"Cables and cable accessories with Un = (3,6 – 500) kV","methodology":"Szczelność:","methodology_en":"Tightness:","parameters":[{"name":"temperatura H2O do T = 85 °C"},{"name":"czas próby do t = 60 dni Water penetration:"}],"parameters_en":[{"name":"H2O temperature up to T = 85 °C"},{"name":"test time up to t = 60 days Water penetration:"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność:\nZakres:\ntemperatura H2O do T = 85 °C\nczas próby do t = 60 dni Water penetration:","reference":"PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60230:2018-01 | IEC 60230:2018+AMD1:2021-12 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","norm_bases":["PN-HD 620 S3:2023-04 HD 620 S3:2023","PN-HD 620 S2:2010-04 HD 620 S2:2010","IEC 60502-2:2014-02","IEC 60502-2:2024-05","IEC 60840:2020-05","IEC 60840:2020+AMD1:2023-06","IEC 62067:2022-04","IEC 60230:2018-01","IEC 60230:2018+AMD1:2021-12","PN-HD 605-S3:2020-05 HD 605 S3:2019","PN-HD 605 S2:2008-10 HD 605 S2:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV Szczelność:\nZakres:\ntemperatura H2O do T = 85 °C\nczas próby do t = 60 dni Water penetration: PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60230:2018-01 | IEC 60230:2018+AMD1:2021-12 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008 Kable i osprzet kablowy o Un = (3,6 – 500) kV Szczelnosc:\nZakres:\ntemperatura H2O do T = 85 °C\nczas proby do t = 60 dni Water penetration: PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60230:2018-01 | IEC 60230:2018+AMD1:2021-12 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 – 500) kV Tightness: H2O temperature up to T = 85 °C test time up to t = 60 days Water penetration: PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60230:2018-01 | IEC 60230:2018+AMD1:2021-12 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","search_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件 PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60230:2018-01 | IEC 60230:2018+AMD1:2021-12 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件"},{"_id":"6a5dc9abf1c10c8ce825a4dc","lab_id":"69ad52a3de79e566650fba73","country":"PL","accr_number":"AB 1917","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV","test_object_en":"Cables and cable accessories with Un = (3,6 – 500) kV","methodology":"Pomiary elektryczne:","methodology_en":"Electrical measurements:","parameters":[{"name":"rezystywność ekranów półprzewodzących"}],"parameters_en":[{"name":"resistivity of semi-conducting screens"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pomiary elektryczne:\nrezystywność ekranów półprzewodzących","reference":"PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","norm_bases":["PN-HD 620 S3:2023-04 HD 620 S3:2023","PN-HD 620 S2:2010-04 HD 620 S2:2010","IEC 60502-2:2014-02","IEC 60502-2:2024-05","IEC 60840:2020-05","IEC 60840:2020+AMD1:2023-06","IEC 62067:2022-04","PN-HD 605-S3:2020-05 HD 605 S3:2019","PN-HD 605 S2:2008-10 HD 605 S2:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV Pomiary elektryczne:\nrezystywność ekranów półprzewodzących PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008 Kable i osprzet kablowy o Un = (3,6 – 500) kV Pomiary elektryczne:\nrezystywnosc ekranow polprzewodzacych PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","categories":["other"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 – 500) kV Electrical measurements: resistivity of semi-conducting screens PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","search_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件 PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件"},{"_id":"6a5dc9abf1c10c8ce825a4dd","lab_id":"69ad52a3de79e566650fba73","country":"PL","accr_number":"AB 1917","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV","test_object_en":"Cables and cable accessories with Un = (3,6 – 500) kV","methodology":"Sprawdzenia konstrukcji i wymiarów:","methodology_en":"Verification of construction and dimensions:","parameters":[{"name":"budowa żyły roboczej,"},{"name":"grubość materiału izolacyjnego i powłokowego"},{"name":"średnica (na izolacji, ekranach półprzewodzących, ekranie metalicznym, kompletnego kabla)"},{"name":"grubość powłoki metalowej"},{"name":"wymiary drutów i taśm metalowych"},{"name":"wymiary taśm niemetalowych"},{"name":"ułożenie elementów ekranu metalicznego (odstępy między drutami, taśmami, skok drutów, taśm)"},{"name":"oznaczenie (nadruk): kompletność nadrukowanego oznaczenia, czytelność i widoczność, trwałość (jeśli jest wymagana), odstępy i powtarzalność"}],"parameters_en":[{"name":"construction of the working conductor,"},{"name":"thickness of insulating and coating material"},{"name":"diameter (over the insulation, semi-conducting screens, metallic screen, complete cable)"},{"name":"metallic coating thickness"},{"name":"dimensions of metal wires and tapes"},{"name":"dimensions of non-metallic tapes"},{"name":"arrangement of metallic screen elements (spacing between wires, tapes, lay of wires, tapes)"},{"name":"marking (print): completeness of the printed marking, legibility and visibility, durability (if required), spacing and repeatability"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawdzenia konstrukcji i wymiarów:\nZakres:\nbudowa żyły roboczej,\ngrubość materiału izolacyjnego i powłokowego\nśrednica (na izolacji, ekranach półprzewodzących, ekranie metalicznym, kompletnego kabla)\ngrubość powłoki metalowej\nwymiary drutów i taśm metalowych\nwymiary taśm niemetalowych\nułożenie elementów ekranu metalicznego (odstępy między drutami, taśmami, skok drutów, taśm)\noznaczenie (nadruk): kompletność nadrukowanego oznaczenia, czytelność i widoczność, trwałość (jeśli jest wymagana), odstępy i powtarzalność","reference":"PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60228:2023-12 | IEC 60811-201:2012 | IEC 60811-201:2012+AMD1:2017 | IEC 60811-201:2012+AMD2:2023 | IEC 60811-202:2012 | IEC 60811-202:2012+AMD1:2017 | IEC 60811-202:2012+AMD2:2023 | IEC 60811-203:2012 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","norm_bases":["PN-HD 620 S3:2023-04 HD 620 S3:2023","PN-HD 620 S2:2010-04 HD 620 S2:2010","IEC 60502-2:2014-02","IEC 60502-2:2024-05","IEC 60840:2020-05","IEC 60840:2020+AMD1:2023-06","IEC 62067:2022-04","IEC 60228:2023-12","IEC 60811-201:2012","IEC 60811-201:2012+AMD1:2017","IEC 60811-201:2012+AMD2:2023","IEC 60811-202:2012","IEC 60811-202:2012+AMD1:2017","IEC 60811-202:2012+AMD2:2023","IEC 60811-203:2012","PN-HD 605-S3:2020-05 HD 605 S3:2019","PN-HD 605 S2:2008-10 HD 605 S2:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV Sprawdzenia konstrukcji i wymiarów:\nZakres:\nbudowa żyły roboczej,\ngrubość materiału izolacyjnego i powłokowego\nśrednica (na izolacji, ekranach półprzewodzących, ekranie metalicznym, kompletnego kabla)\ngrubość powłoki metalowej\nwymiary drutów i taśm metalowych\nwymiary taśm niemetalowych\nułożenie elementów ekranu metalicznego (odstępy między drutami, taśmami, skok drutów, taśm)\noznaczenie (nadruk): kompletność nadrukowanego oznaczenia, czytelność i widoczność, trwałość (jeśli jest wymagana), odstępy i powtarzalność PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60228:2023-12 | IEC 60811-201:2012 | IEC 60811-201:2012+AMD1:2017 | IEC 60811-201:2012+AMD2:2023 | IEC 60811-202:2012 | IEC 60811-202:2012+AMD1:2017 | IEC 60811-202:2012+AMD2:2023 | IEC 60811-203:2012 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008 Kable i osprzet kablowy o Un = (3,6 – 500) kV Sprawdzenia konstrukcji i wymiarow:\nZakres:\nbudowa zyly roboczej,\ngrubosc materialu izolacyjnego i powlokowego\nsrednica (na izolacji, ekranach polprzewodzacych, ekranie metalicznym, kompletnego kabla)\ngrubosc powloki metalowej\nwymiary drutow i tasm metalowych\nwymiary tasm niemetalowych\nulozenie elementow ekranu metalicznego (odstepy miedzy drutami, tasmami, skok drutow, tasm)\noznaczenie (nadruk): kompletnosc nadrukowanego oznaczenia, czytelnosc i widocznosc, trwalosc (jesli jest wymagana), odstepy i powtarzalnosc PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60228:2023-12 | IEC 60811-201:2012 | IEC 60811-201:2012+AMD1:2017 | IEC 60811-201:2012+AMD2:2023 | IEC 60811-202:2012 | IEC 60811-202:2012+AMD1:2017 | IEC 60811-202:2012+AMD2:2023 | IEC 60811-203:2012 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","categories":["materials","construction"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 – 500) kV Verification of construction and dimensions: construction of the working conductor, thickness of insulating and coating material diameter (over the insulation, semi-conducting screens, metallic screen, complete cable) metallic coating thickness dimensions of metal wires and tapes dimensions of non-metallic tapes arrangement of metallic screen elements (spacing between wires, tapes, lay of wires, tapes) marking (print): completeness of the printed marking, legibility and visibility, durability (if required), spacing and repeatability PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60228:2023-12 | IEC 60811-201:2012 | IEC 60811-201:2012+AMD1:2017 | IEC 60811-201:2012+AMD2:2023 | IEC 60811-202:2012 | IEC 60811-202:2012+AMD1:2017 | IEC 60811-202:2012+AMD2:2023 | IEC 60811-203:2012 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","search_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件 PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60228:2023-12 | IEC 60811-201:2012 | IEC 60811-201:2012+AMD1:2017 | IEC 60811-201:2012+AMD2:2023 | IEC 60811-202:2012 | IEC 60811-202:2012+AMD1:2017 | IEC 60811-202:2012+AMD2:2023 | IEC 60811-203:2012 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008","test_object_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件"},{"_id":"6a5dc9abf1c10c8ce825a4de","lab_id":"69ad52a3de79e566650fba73","country":"PL","accr_number":"AB 1917","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV","test_object_en":"Cables and cable accessories with Un = (3,6 – 500) kV","methodology":"Sprawdzenie własności fizycznych materiałów","methodology_en":"Verification of the physical properties of materials","parameters":[{"name":"ubytek masy powłoki"},{"name":"nasiąkliwość wodą"},{"name":"gęstość"}],"parameters_en":[{"name":"coating mass loss"},{"name":"water absorption"},{"name":"density"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawdzenie własności fizycznych materiałów\nZakres:\nubytek masy powłoki\nnasiąkliwość wodą\ngęstość","reference":"PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-409:2012 | IEC 60811-402:2012 | IEC 60811-606:2012","norm_bases":["PN-HD 620 S3:2023-04 HD 620 S3:2023","PN-HD 620 S2:2010-04 HD 620 S2:2010","IEC 60502-2:2014-02","IEC 60502-2:2024-05","IEC 60840:2020-05","IEC 60840:2020+AMD1:2023-06","IEC 62067:2022-04","IEC 60811-409:2012","IEC 60811-402:2012","IEC 60811-606:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV Sprawdzenie własności fizycznych materiałów\nZakres:\nubytek masy powłoki\nnasiąkliwość wodą\ngęstość PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-409:2012 | IEC 60811-402:2012 | IEC 60811-606:2012 Kable i osprzet kablowy o Un = (3,6 – 500) kV Sprawdzenie wlasnosci fizycznych materialow\nZakres:\nubytek masy powloki\nnasiakliwosc woda\ngestosc PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-409:2012 | IEC 60811-402:2012 | IEC 60811-606:2012","categories":["materials"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 – 500) kV Verification of the physical properties of materials coating mass loss water absorption density PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-409:2012 | IEC 60811-402:2012 | IEC 60811-606:2012","search_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件 PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-409:2012 | IEC 60811-402:2012 | IEC 60811-606:2012","test_object_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件"},{"_id":"6a5dc9abf1c10c8ce825a4df","lab_id":"69ad52a3de79e566650fba73","country":"PL","accr_number":"AB 1917","accr_body":"PCA","test_object":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV","test_object_en":"Cables and cable accessories with Un = (3,6 – 500) kV","methodology":"Sprawdzenie własności mechanicznych materiałów:","methodology_en":"Verification of the mechanical properties of materials:","parameters":[{"name":"własności mechaniczne izolacji przed i po starzeniu"},{"name":"własności mechaniczne materiałów po starzeniu próbki kompletnego kabla"},{"name":"odporność na nacisk w podwyższonej temperaturze"},{"name":"odporność na działanie niskiej temperatury"},{"name":"odporność na pęknięcia (heat shock test)"},{"name":"hot set test izolacji"},{"name":"odporność powłoki elastomerowej na działanie oleju"},{"name":"skurcz izolacji"},{"name":"stabilność termiczna"},{"name":"skurcz powłoki"},{"name":"siła odrywania ekranu izolacji"},{"name":"badania elementów kabli z wzdłużnie nałożoną taśmą lub folią metalową, przyklejoną do powłoki zewnętrznej (ocena wizualna, adhezja i wytrzymałość na odrywanie)"}],"parameters_en":[{"name":"mechanical properties of the insulation before and after ageing"},{"name":"mechanical properties of materials after ageing of a complete cable sample"},{"name":"resistance to pressure at elevated temperature"},{"name":"resistance to low temperature"},{"name":"resistance to cracking (heat shock test)"},{"name":"hot set test of insulation"},{"name":"resistance of the elastomeric coating to oil"},{"name":"insulation shrinkage"},{"name":"thermal stability"},{"name":"sheath shrinkage"},{"name":"insulation screen peel force"},{"name":"testing of cable components with a longitudinally applied metal tape or foil bonded to the outer sheath (visual assessment, adhesion and peel strength)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawdzenie własności mechanicznych materiałów:\nZakres:\nwłasności mechaniczne izolacji przed i po starzeniu\nwłasności mechaniczne materiałów po starzeniu próbki kompletnego kabla\nodporność na nacisk w podwyższonej temperaturze\nodporność na działanie niskiej temperatury\nodporność na pęknięcia (heat shock test)\nhot set test izolacji\nodporność powłoki elastomerowej na działanie oleju\nskurcz izolacji\nstabilność termiczna\nskurcz powłoki\nsiła odrywania ekranu izolacji\nbadania elementów kabli z wzdłużnie nałożoną taśmą lub folią metalową, przyklejoną do powłoki zewnętrznej (ocena wizualna, adhezja i wytrzymałość na odrywanie)","reference":"PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-401:2012 | IEC 60811-401:2017 | IEC 60811-501:2012 | IEC 60811-501:2012+AMD1:2018 | IEC 60811-501:2012+AMD2:2023 | IEC 60811-508:2012 | IEC 60811-508:2012+AMD1:2017 | IEC 60811-508:2012+AMD2:2023 | IEC 60811-507:2012 | IEC 60811-505:2012 | IEC 60811-506:2012 | IEC 60811-509:2012 | IEC 60811-509:2012+AMD1:2017 | IEC 60811-404:2012 | IEC 60811-405:2012 | IEC 60811-502:2012 | IEC 60811-503:2012+AMD1:2023 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008 Scope of accreditation No. AB 1917","norm_bases":["PN-HD 620 S3:2023-04 HD 620 S3:2023","PN-HD 620 S2:2010-04 HD 620 S2:2010","IEC 60502-2:2014-02","IEC 60502-2:2024-05","IEC 60840:2020-05","IEC 60840:2020+AMD1:2023-06","IEC 62067:2022-04","IEC 60811-401:2012","IEC 60811-401:2017","IEC 60811-501:2012","IEC 60811-501:2012+AMD1:2018","IEC 60811-501:2012+AMD2:2023","IEC 60811-508:2012","IEC 60811-508:2012+AMD1:2017","IEC 60811-508:2012+AMD2:2023","IEC 60811-507:2012","IEC 60811-505:2012","IEC 60811-506:2012","IEC 60811-509:2012","IEC 60811-509:2012+AMD1:2017","IEC 60811-404:2012","IEC 60811-405:2012","IEC 60811-502:2012","IEC 60811-503:2012+AMD1:2023","PN-HD 605-S3:2020-05 HD 605 S3:2019","PN-HD 605 S2:2008-10 HD 605 S2:2008 Scope of accreditation No. AB 1917"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable i osprzęt kablowy o Un = (3,6 – 500) kV Sprawdzenie własności mechanicznych materiałów:\nZakres:\nwłasności mechaniczne izolacji przed i po starzeniu\nwłasności mechaniczne materiałów po starzeniu próbki kompletnego kabla\nodporność na nacisk w podwyższonej temperaturze\nodporność na działanie niskiej temperatury\nodporność na pęknięcia (heat shock test)\nhot set test izolacji\nodporność powłoki elastomerowej na działanie oleju\nskurcz izolacji\nstabilność termiczna\nskurcz powłoki\nsiła odrywania ekranu izolacji\nbadania elementów kabli z wzdłużnie nałożoną taśmą lub folią metalową, przyklejoną do powłoki zewnętrznej (ocena wizualna, adhezja i wytrzymałość na odrywanie) PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-401:2012 | IEC 60811-401:2017 | IEC 60811-501:2012 | IEC 60811-501:2012+AMD1:2018 | IEC 60811-501:2012+AMD2:2023 | IEC 60811-508:2012 | IEC 60811-508:2012+AMD1:2017 | IEC 60811-508:2012+AMD2:2023 | IEC 60811-507:2012 | IEC 60811-505:2012 | IEC 60811-506:2012 | IEC 60811-509:2012 | IEC 60811-509:2012+AMD1:2017 | IEC 60811-404:2012 | IEC 60811-405:2012 | IEC 60811-502:2012 | IEC 60811-503:2012+AMD1:2023 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008 Scope of accreditation No. AB 1917 Kable i osprzet kablowy o Un = (3,6 – 500) kV Sprawdzenie wlasnosci mechanicznych materialow:\nZakres:\nwlasnosci mechaniczne izolacji przed i po starzeniu\nwlasnosci mechaniczne materialow po starzeniu probki kompletnego kabla\nodpornosc na nacisk w podwyzszonej temperaturze\nodpornosc na dzialanie niskiej temperatury\nodpornosc na pekniecia (heat shock test)\nhot set test izolacji\nodpornosc powloki elastomerowej na dzialanie oleju\nskurcz izolacji\nstabilnosc termiczna\nskurcz powloki\nsila odrywania ekranu izolacji\nbadania elementow kabli z wzdluznie nalozona tasma lub folia metalowa, przyklejona do powloki zewnetrznej (ocena wizualna, adhezja i wytrzymalosc na odrywanie) PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-401:2012 | IEC 60811-401:2017 | IEC 60811-501:2012 | IEC 60811-501:2012+AMD1:2018 | IEC 60811-501:2012+AMD2:2023 | IEC 60811-508:2012 | IEC 60811-508:2012+AMD1:2017 | IEC 60811-508:2012+AMD2:2023 | IEC 60811-507:2012 | IEC 60811-505:2012 | IEC 60811-506:2012 | IEC 60811-509:2012 | IEC 60811-509:2012+AMD1:2017 | IEC 60811-404:2012 | IEC 60811-405:2012 | IEC 60811-502:2012 | IEC 60811-503:2012+AMD1:2023 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008 Scope of accreditation No. AB 1917","categories":["materials","petro","construction"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables and cable accessories with Un = (3,6 – 500) kV Verification of the mechanical properties of materials: mechanical properties of the insulation before and after ageing mechanical properties of materials after ageing of a complete cable sample resistance to pressure at elevated temperature resistance to low temperature resistance to cracking (heat shock test) hot set test of insulation resistance of the elastomeric coating to oil insulation shrinkage thermal stability sheath shrinkage insulation screen peel force testing of cable components with a longitudinally applied metal tape or foil bonded to the outer sheath (visual assessment, adhesion and peel strength) PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-401:2012 | IEC 60811-401:2017 | IEC 60811-501:2012 | IEC 60811-501:2012+AMD1:2018 | IEC 60811-501:2012+AMD2:2023 | IEC 60811-508:2012 | IEC 60811-508:2012+AMD1:2017 | IEC 60811-508:2012+AMD2:2023 | IEC 60811-507:2012 | IEC 60811-505:2012 | IEC 60811-506:2012 | IEC 60811-509:2012 | IEC 60811-509:2012+AMD1:2017 | IEC 60811-404:2012 | IEC 60811-405:2012 | IEC 60811-502:2012 | IEC 60811-503:2012+AMD1:2023 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008 Scope of accreditation No. AB 1917","search_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件 PN-HD 620 S3:2023-04 HD 620 S3:2023 | PN-HD 620 S2:2010-04 HD 620 S2:2010 | IEC 60502-2:2014-02 | IEC 60502-2:2024-05 | IEC 60840:2020-05 | IEC 60840:2020+AMD1:2023-06 | IEC 62067:2022-04 | IEC 60811-401:2012 | IEC 60811-401:2017 | IEC 60811-501:2012 | IEC 60811-501:2012+AMD1:2018 | IEC 60811-501:2012+AMD2:2023 | IEC 60811-508:2012 | IEC 60811-508:2012+AMD1:2017 | IEC 60811-508:2012+AMD2:2023 | IEC 60811-507:2012 | IEC 60811-505:2012 | IEC 60811-506:2012 | IEC 60811-509:2012 | IEC 60811-509:2012+AMD1:2017 | IEC 60811-404:2012 | IEC 60811-405:2012 | IEC 60811-502:2012 | IEC 60811-503:2012+AMD1:2023 | PN-HD 605-S3:2020-05 HD 605 S3:2019 | PN-HD 605 S2:2008-10 HD 605 S2:2008 Scope of accreditation No. AB 1917","test_object_zh":"Un = (3,6 – 500) kV 的电缆与电缆附件"}],"has_pdf":true}