{"lab":{"_id":"69ad52a3de79e566650fba6d","country":"PL","accr_number":"AB 1914","accr_body":"PCA","address":"ul. Galaktyczna 3, 80-299 Gdańsk","categories":["other"],"city":"Gdańsk","imported_at":"2026-03-08T10:42:43.265Z","methods_count":11,"name":"SINEO Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1914.pdf"],"scope_summary":"","search_text":"sineo sp. z o.o. ul. galaktyczna 3, 80-299 gdańsk other materials environment","status":"active","updated_at":"2026-03-08T14:51:02.593Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:04:36.783Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201914,podmiot.html","fields_of_testing":[{"codes":"J/31","pl":"Badania mechaniczne gruntów i skał","en":"Mechanical tests of ground and rocks"},{"codes":"N/31","pl":"Badania właściwości fizycznych gruntów i skał","en":"Tests of physical properties of ground and rocks"}],"issue":{"no":"2","date":"17.07.2026"},"parse_date":"2026-08-13T08:04:36.783Z","parse_source":"agent-claude-code","map_coord":[54.427106,18.486813],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium mechaniki gruntów","address":"ul. Galaktyczna 3, 80-299 Gdańsk","city":"Gdańsk","postal":"80-299"}],"scope_format":"PCA::pracownie+siatka6","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/bdd2ea0a3689e481d23b4db18c3139cb/AB%201914.pdf","has_en":true,"category_counts":{"other":11},"category_scores":{"other":11},"has_zh":true,"lab_locations_zh":[{"name":"土力学实验室","address":"ul. Galaktyczna 3, 80-299 Gdańsk","city":"Gdańsk","postal":"80-299"}]},"methods":[{"_id":"6a7d7a940636ba417e41b6bc","lab_id":"69ad52a3de79e566650fba6d","country":"PL","accr_number":"AB 1914","accr_body":"PCA","test_object":"Grunty","methodology":"Wilgotność naturalna","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Wilgotność naturalna\nMetoda wagowa","reference":"PN-EN ISO 17892-1:2015-02","norm_bases":["PN-EN ISO 17892-1:2015-02"],"lab_section":"Laboratorium mechaniki gruntów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wilgotność naturalna\nMetoda wagowa PN-EN ISO 17892-1:2015-02 Grunty Wilgotnosc naturalna\nMetoda wagowa PN-EN ISO 17892-1:2015-02","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Soil mechanics laboratory","methodology_en":"Natural moisture content","search_en":"Ground Natural moisture content Gravimetric method Soil mechanics laboratory PN-EN ISO 17892-1:2015-02","technique_en":"Gravimetric method","test_object_en":"Ground","search_zh":"土体 天然含水率 重量法 土力学实验室 PN-EN ISO 17892-1:2015-02","technique_zh":"重量法","test_object_zh":"土体","methodology_zh":"天然含水率","lab_section_zh":"土力学实验室"},{"_id":"6a7d7a940636ba417e41b6bd","lab_id":"69ad52a3de79e566650fba6d","country":"PL","accr_number":"AB 1914","accr_body":"PCA","test_object":"Grunty","methodology":"Skład granulometryczny","parameters":[{"name":"Zakres","range":"(0,063 – 63,0) mm"}],"technique":"Metoda sitowa","techniques":["Metoda sitowa"],"computed":[],"activity":"Skład granulometryczny\nZakres (0,063 – 63,0) mm\nMetoda sitowa","reference":"PN-EN ISO 17892-4:2017-01","norm_bases":["PN-EN ISO 17892-4:2017-01"],"lab_section":"Laboratorium mechaniki gruntów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Skład granulometryczny\nZakres (0,063 – 63,0) mm\nMetoda sitowa PN-EN ISO 17892-4:2017-01 Grunty Sklad granulometryczny\nZakres (0,063 – 63,0) mm\nMetoda sitowa PN-EN ISO 17892-4:2017-01","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Soil mechanics laboratory","methodology_en":"Particle size distribution","parameters_en":[{"name":"Range","range":"(0,063 – 63,0) mm"}],"search_en":"Ground Particle size distribution Sieve method Soil mechanics laboratory Range PN-EN ISO 17892-4:2017-01","technique_en":"Sieve method","test_object_en":"Ground","parameters_zh":[{"name":"范围","range":"(0,063 – 63,0) mm"}],"search_zh":"土体 粒度组成 筛析法 土力学实验室 范围 PN-EN ISO 17892-4:2017-01","test_object_zh":"土体","methodology_zh":"粒度组成","technique_zh":"筛析法","lab_section_zh":"土力学实验室"},{"_id":"6a7d7a940636ba417e41b6be","lab_id":"69ad52a3de79e566650fba6d","country":"PL","accr_number":"AB 1914","accr_body":"PCA","test_object":"Grunty","methodology":"Skład granulometryczny","parameters":[{"name":"Zakres","range":"(0,0 – 0,063) mm"}],"technique":"Metoda areometryczna","techniques":["Metoda areometryczna"],"computed":[],"activity":"Skład granulometryczny\nZakres (0,0 – 0,063) mm\nMetoda areometryczna","reference":"PN-EN ISO 17892-4:2017-01","norm_bases":["PN-EN ISO 17892-4:2017-01"],"lab_section":"Laboratorium mechaniki gruntów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Skład granulometryczny\nZakres (0,0 – 0,063) mm\nMetoda areometryczna PN-EN ISO 17892-4:2017-01 Grunty Sklad granulometryczny\nZakres (0,0 – 0,063) mm\nMetoda areometryczna PN-EN ISO 17892-4:2017-01","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Soil mechanics laboratory","methodology_en":"Particle size distribution","parameters_en":[{"name":"Range","range":"(0,0 – 0,063) mm"}],"search_en":"Ground Particle size distribution Hydrometer method Soil mechanics laboratory Range PN-EN ISO 17892-4:2017-01","technique_en":"Hydrometer method","test_object_en":"Ground","parameters_zh":[{"name":"范围","range":"(0,0 – 0,063) mm"}],"search_zh":"土体 粒度组成 比重计法 土力学实验室 范围 PN-EN ISO 17892-4:2017-01","test_object_zh":"土体","methodology_zh":"粒度组成","technique_zh":"比重计法","lab_section_zh":"土力学实验室"},{"_id":"6a7d7a940636ba417e41b6bf","lab_id":"69ad52a3de79e566650fba6d","country":"PL","accr_number":"AB 1914","accr_body":"PCA","test_object":"Grunty","methodology":"Granica plastyczności","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Granica plastyczności","reference":"PN-EN ISO 17892-12:2018-08","norm_bases":["PN-EN ISO 17892-12:2018-08"],"lab_section":"Laboratorium mechaniki gruntów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Granica plastyczności PN-EN ISO 17892-12:2018-08 Grunty Granica plastycznosci PN-EN ISO 17892-12:2018-08","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Soil mechanics laboratory","methodology_en":"Yield strength","search_en":"Ground Yield strength Soil mechanics laboratory PN-EN ISO 17892-12:2018-08","test_object_en":"Ground","search_zh":"土体 屈服强度 土力学实验室 PN-EN ISO 17892-12:2018-08","test_object_zh":"土体","lab_section_zh":"土力学实验室","methodology_zh":"屈服强度"},{"_id":"6a7d7a940636ba417e41b6c0","lab_id":"69ad52a3de79e566650fba6d","country":"PL","accr_number":"AB 1914","accr_body":"PCA","test_object":"Grunty","methodology":"Granica płynności","parameters":[],"technique":"Metoda penetrometru stożkowego","techniques":["Metoda penetrometru stożkowego"],"computed":[],"activity":"Granica płynności\nMetoda penetrometru stożkowego","reference":"PN-EN ISO 17892-12:2018-08","norm_bases":["PN-EN ISO 17892-12:2018-08"],"lab_section":"Laboratorium mechaniki gruntów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Granica płynności\nMetoda penetrometru stożkowego PN-EN ISO 17892-12:2018-08 Grunty Granica plynnosci\nMetoda penetrometru stozkowego PN-EN ISO 17892-12:2018-08","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Soil mechanics laboratory","methodology_en":"Liquid limit","search_en":"Ground Liquid limit Cone penetrometer method Soil mechanics laboratory PN-EN ISO 17892-12:2018-08","technique_en":"Cone penetrometer method","test_object_en":"Ground","search_zh":"土体 液限 锥式贯入仪法 土力学实验室 PN-EN ISO 17892-12:2018-08","test_object_zh":"土体","lab_section_zh":"土力学实验室","methodology_zh":"液限","technique_zh":"锥式贯入仪法"},{"_id":"6a7d7a940636ba417e41b6c1","lab_id":"69ad52a3de79e566650fba6d","country":"PL","accr_number":"AB 1914","accr_body":"PCA","test_object":"Grunty","methodology":"Ściśliwość i konsolidacja gruntu","parameters":[{"name":"Zakres","range":"(0 – 32000) kPa"}],"technique":"Metoda edometryczna","techniques":["Metoda edometryczna"],"computed":[],"activity":"Ściśliwość i konsolidacja gruntu\nZakres (0 – 32000) kPa\nMetoda edometryczna","reference":"PN-EN ISO 17892-5:2017-06","norm_bases":["PN-EN ISO 17892-5:2017-06"],"lab_section":"Laboratorium mechaniki gruntów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Ściśliwość i konsolidacja gruntu\nZakres (0 – 32000) kPa\nMetoda edometryczna PN-EN ISO 17892-5:2017-06 Grunty Scisliwosc i konsolidacja gruntu\nZakres (0 – 32000) kPa\nMetoda edometryczna PN-EN ISO 17892-5:2017-06","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Soil mechanics laboratory","methodology_en":"Compressibility and consolidation of soil","parameters_en":[{"name":"Range","range":"(0 – 32000) kPa"}],"search_en":"Ground Compressibility and consolidation of soil Oedometer method Soil mechanics laboratory Range PN-EN ISO 17892-5:2017-06","technique_en":"Oedometer method","test_object_en":"Ground","parameters_zh":[{"name":"范围","range":"(0 – 32000) kPa"}],"search_zh":"土体 土力学实验室 范围 PN-EN ISO 17892-5:2017-06","test_object_zh":"土体","lab_section_zh":"土力学实验室"},{"_id":"6a7d7a940636ba417e41b6c2","lab_id":"69ad52a3de79e566650fba6d","country":"PL","accr_number":"AB 1914","accr_body":"PCA","test_object":"Grunty","methodology":"Badanie w aparacie bezpośredniego ścinania","parameters":[{"name":"obciążenia","range":"(0 – 10) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Badanie w aparacie bezpośredniego ścinania\nobciążenia (0 – 10) kN","reference":"PN-EN ISO 17892-10:2019-01","norm_bases":["PN-EN ISO 17892-10:2019-01"],"lab_section":"Laboratorium mechaniki gruntów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Badanie w aparacie bezpośredniego ścinania\nobciążenia (0 – 10) kN PN-EN ISO 17892-10:2019-01 Grunty Badanie w aparacie bezposredniego scinania\nobciazenia (0 – 10) kN PN-EN ISO 17892-10:2019-01","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Soil mechanics laboratory","methodology_en":"Direct shear apparatus test","parameters_en":[{"name":"loads","range":"(0 – 10) kN"}],"search_en":"Ground Direct shear apparatus test Soil mechanics laboratory loads PN-EN ISO 17892-10:2019-01","test_object_en":"Ground","search_zh":"土体 土力学实验室 PN-EN ISO 17892-10:2019-01","test_object_zh":"土体","lab_section_zh":"土力学实验室"},{"_id":"6a7d7a940636ba417e41b6c3","lab_id":"69ad52a3de79e566650fba6d","country":"PL","accr_number":"AB 1914","accr_body":"PCA","test_object":"Grunty","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"ciśnienie w komorze","range":"(0 – 3000) kPa"}],"technique":"Metoda trójosiowego ściskania bez konsolidacji i bez drenażu (UU)","techniques":["Metoda trójosiowego ściskania bez konsolidacji i bez drenażu (UU)"],"computed":[],"activity":"Wytrzymałość na ściskanie\nciśnienie w komorze (0 – 3000) kPa\nMetoda trójosiowego ściskania bez konsolidacji i bez drenażu (UU)","reference":"PN-EN ISO 17892-8:2018-05","norm_bases":["PN-EN ISO 17892-8:2018-05"],"lab_section":"Laboratorium mechaniki gruntów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wytrzymałość na ściskanie\nciśnienie w komorze (0 – 3000) kPa\nMetoda trójosiowego ściskania bez konsolidacji i bez drenażu (UU) PN-EN ISO 17892-8:2018-05 Grunty Wytrzymalosc na sciskanie\ncisnienie w komorze (0 – 3000) kPa\nMetoda trojosiowego sciskania bez konsolidacji i bez drenazu (UU) PN-EN ISO 17892-8:2018-05","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Soil mechanics laboratory","methodology_en":"Compressive strength","parameters_en":[{"name":"chamber pressure","range":"(0 – 3000) kPa"}],"search_en":"Ground Compressive strength Triaxial compression method without consolidation and without drainage (UU) Soil mechanics laboratory chamber pressure PN-EN ISO 17892-8:2018-05","technique_en":"Triaxial compression method without consolidation and without drainage (UU)","test_object_en":"Ground","methodology_zh":"抗压强度","search_zh":"土体 抗压强度 土力学实验室 腔内压力 PN-EN ISO 17892-8:2018-05","test_object_zh":"土体","lab_section_zh":"土力学实验室","parameters_zh":[{"name":"腔内压力","range":"(0 – 3000) kPa"}]},{"_id":"6a7d7a940636ba417e41b6c4","lab_id":"69ad52a3de79e566650fba6d","country":"PL","accr_number":"AB 1914","accr_body":"PCA","test_object":"Grunty","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"ciśnienie w komorze","range":"(0 – 3000) kPa"}],"technique":"Metoda trójosiowego ściskania z konsolidacją i bez drenażu (CU)","techniques":["Metoda trójosiowego ściskania z konsolidacją i bez drenażu (CU)"],"computed":[],"activity":"Wytrzymałość na ściskanie\nciśnienie w komorze (0 – 3000) kPa\nMetoda trójosiowego ściskania z konsolidacją i bez drenażu (CU)","reference":"PN-EN ISO 17892-9:2018-05","norm_bases":["PN-EN ISO 17892-9:2018-05"],"lab_section":"Laboratorium mechaniki gruntów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wytrzymałość na ściskanie\nciśnienie w komorze (0 – 3000) kPa\nMetoda trójosiowego ściskania z konsolidacją i bez drenażu (CU) PN-EN ISO 17892-9:2018-05 Grunty Wytrzymalosc na sciskanie\ncisnienie w komorze (0 – 3000) kPa\nMetoda trojosiowego sciskania z konsolidacja i bez drenazu (CU) PN-EN ISO 17892-9:2018-05","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Soil mechanics laboratory","methodology_en":"Compressive strength","parameters_en":[{"name":"chamber pressure","range":"(0 – 3000) kPa"}],"search_en":"Ground Compressive strength Triaxial compression method with consolidation and without drainage (CU) Soil mechanics laboratory chamber pressure PN-EN ISO 17892-9:2018-05","technique_en":"Triaxial compression method with consolidation and without drainage (CU)","test_object_en":"Ground","methodology_zh":"抗压强度","search_zh":"土体 抗压强度 土力学实验室 腔内压力 PN-EN ISO 17892-9:2018-05","test_object_zh":"土体","lab_section_zh":"土力学实验室","parameters_zh":[{"name":"腔内压力","range":"(0 – 3000) kPa"}]},{"_id":"6a7d7a940636ba417e41b6c5","lab_id":"69ad52a3de79e566650fba6d","country":"PL","accr_number":"AB 1914","accr_body":"PCA","test_object":"Grunty","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"ciśnienie w komorze","range":"(0 – 3000) kPa"}],"technique":"Metoda trójosiowego ściskania z konsolidacją i z drenażem (CD)","techniques":["Metoda trójosiowego ściskania z konsolidacją i z drenażem (CD)"],"computed":[],"activity":"Wytrzymałość na ściskanie\nciśnienie w komorze (0 – 3000) kPa\nMetoda trójosiowego ściskania z konsolidacją i z drenażem (CD)","reference":"PN-EN ISO 17892-9:2018-05","norm_bases":["PN-EN ISO 17892-9:2018-05"],"lab_section":"Laboratorium mechaniki gruntów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wytrzymałość na ściskanie\nciśnienie w komorze (0 – 3000) kPa\nMetoda trójosiowego ściskania z konsolidacją i z drenażem (CD) PN-EN ISO 17892-9:2018-05 Grunty Wytrzymalosc na sciskanie\ncisnienie w komorze (0 – 3000) kPa\nMetoda trojosiowego sciskania z konsolidacja i z drenazem (CD) PN-EN ISO 17892-9:2018-05","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Soil mechanics laboratory","methodology_en":"Compressive strength","parameters_en":[{"name":"chamber pressure","range":"(0 – 3000) kPa"}],"search_en":"Ground Compressive strength Triaxial compression method with consolidation and with drainage (CD) Soil mechanics laboratory chamber pressure PN-EN ISO 17892-9:2018-05","technique_en":"Triaxial compression method with consolidation and with drainage (CD)","test_object_en":"Ground","methodology_zh":"抗压强度","search_zh":"土体 抗压强度 土力学实验室 腔内压力 PN-EN ISO 17892-9:2018-05","test_object_zh":"土体","lab_section_zh":"土力学实验室","parameters_zh":[{"name":"腔内压力","range":"(0 – 3000) kPa"}]},{"_id":"6a7d7a940636ba417e41b6c6","lab_id":"69ad52a3de79e566650fba6d","country":"PL","accr_number":"AB 1914","accr_body":"PCA","test_object":"Grunty","methodology":"Oznaczenie przewodności termicznej","parameters":[],"technique":"Metoda igły termicznej","techniques":["Metoda igły termicznej"],"computed":[],"activity":"Oznaczenie przewodności termicznej\nMetoda igły termicznej","reference":"ASTM D5334-22ae1","norm_bases":["ASTM D5334-22ae1"],"lab_section":"Laboratorium mechaniki gruntów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Oznaczenie przewodności termicznej\nMetoda igły termicznej ASTM D5334-22ae1 Grunty Oznaczenie przewodnosci termicznej\nMetoda igly termicznej ASTM D5334-22ae1","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Soil mechanics laboratory","methodology_en":"Determination of thermal conductivity","search_en":"Ground Determination of thermal conductivity Thermal needle method Soil mechanics laboratory ASTM D5334-22ae1","technique_en":"Thermal needle method","test_object_en":"Ground","search_zh":"土体 热针法 土力学实验室 ASTM D5334-22ae1","test_object_zh":"土体","lab_section_zh":"土力学实验室","technique_zh":"热针法"}],"has_pdf":true}