{"lab":{"_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","address":"Laboratorium Badawcze, ul. 1 Maja 2, 41-100 Siemianowice Śląskie","categories":["petro","environment"],"city":"Siemianowice Śląskie","imported_at":"2026-03-08T10:42:43.265Z","methods_count":51,"name":"MARLEY LABORATORIUM Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1913.pdf"],"scope_summary":"","search_text":"marley laboratorium sp. z o.o. laboratorium badawcze, ul. 1 maja 2, 41-100 siemianowice śląskie petro other automotive environment","status":"active","updated_at":"2026-03-08T14:51:02.540Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:02.540Z","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%201913,podmiot.html","fields_of_testing":[{"codes":"C/10; C/32","pl":"Badania chemiczne paliw (stałych), odpadów","en":"Chemical tests of fuels (solid), waste"},{"codes":"N/10; N/32","pl":"Badania właściwości fizycznych paliw (stałych), odpadów","en":"Tests of physical properties of fuels (solid), waste"},{"codes":"P/10","pl":"Pobieranie próbek paliw (stałych)","en":"Sampling of fuels (solid)"}],"issue":{"no":"2","date":"02.09.2025"},"parse_date":"2026-07-20T07:09:57.543Z","parse_source":"script-pdfplumber","map_coord":[50.302658,19.03278],"map_geo":"nominatim-street","has_en":true,"category_counts":{"petro":47,"environment":17},"category_scores":{"petro":34.52,"environment":4.52},"has_zh":true},"methods":[{"_id":"6a5dc9c5f1c10c8ce82603b2","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-G-04502:2014-11 z wyłączeniem pkt. 5.3.1; 5.3.2; 5.3.5","norm_bases":["PN-G-04502:2014-11 z wyłączeniem pkt. 5.3.1; 5.3.2; 5.3.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Pobieranie próbek do badań chemicznych i fizycznych PN-G-04502:2014-11 z wyłączeniem pkt. 5.3.1; 5.3.2; 5.3.5 Paliwa stale: wegiel kamienny Pobieranie probek do badan chemicznych i fizycznych PN-G-04502:2014-11 z wylaczeniem pkt. 5.3.1; 5.3.2; 5.3.5","categories":["petro"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Sampling for chemical and physical testing PN-G-04502:2014-11 z wyłączeniem pkt. 5.3.1; 5.3.2; 5.3.5","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：烟煤 化学与物理检测用样品采集 PN-G-04502:2014-11 z wyłączeniem pkt. 5.3.1; 5.3.2; 5.3.5","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c5f1c10c8ce82603b3","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(1,0 – 30,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 30,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (1,0 – 30,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006 z wyłączeniem metody A1, A2, B2","norm_bases":["PN-ISO 589:2006 z wyłączeniem metody A1, A2, B2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej\nZakres (1,0 – 30,0) %\nMetoda wagowa PN-ISO 589:2006 z wyłączeniem metody A1, A2, B2 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej\nZakres (1,0 – 30,0) %\nMetoda wagowa PN-ISO 589:2006 z wylaczeniem metody A1, A2, B2","categories":["petro"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Total moisture content Gravimetric method Range PN-ISO 589:2006 z wyłączeniem metody A1, A2, B2","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 30,0) %"}],"search_zh":"固体燃料：烟煤 全水分含量 重量法 范围 PN-ISO 589:2006 z wyłączeniem metody A1, A2, B2","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c5f1c10c8ce82603b4","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość części lotnych","methodology_en":"Volatile matter content","parameters":[{"name":"Zakres","range":"(2,00 – 37,00) %"}],"parameters_en":[{"name":"Range","range":"(2,00 – 37,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość części lotnych\nZakres (2,00 – 37,00) %\nMetoda wagowa","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość części lotnych\nZakres (2,00 – 37,00) %\nMetoda wagowa PN-G-04516:1998 Paliwa stale: wegiel kamienny Zawartosc czesci lotnych\nZakres (2,00 – 37,00) %\nMetoda wagowa PN-G-04516:1998","categories":["petro"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Volatile matter content Gravimetric method Range PN-G-04516:1998","parameters_zh":[{"name":"范围","range":"(2,00 – 37,00) %"}],"search_zh":"固体燃料：烟煤 挥发分含量 重量法 范围 PN-G-04516:1998","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"挥发分含量"},{"_id":"6a5dc9c5f1c10c8ce82603b5","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość części lotnych","methodology_en":"Volatile matter content","parameters":[{"name":"Zakres","range":"(2,00 – 37,00) %"}],"parameters_en":[{"name":"Range","range":"(2,00 – 37,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość części lotnych\nZakres (2,00 – 37,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość części lotnych\nZakres (2,00 – 37,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc czesci lotnych\nZakres (2,00 – 37,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Volatile matter content Thermogravimetric method (TGA) Range PN-G-04560:1998","parameters_zh":[{"name":"范围","range":"(2,00 – 37,00) %"}],"search_zh":"固体燃料：烟煤 挥发分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤","methodology_zh":"挥发分含量"},{"_id":"6a5dc9c5f1c10c8ce82603b6","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zdolność spiekania","methodology_en":"Caking ability","parameters":[{"name":"Zakres","range":"1 – 90"}],"parameters_en":[{"name":"Range","range":"1 – 90"}],"technique":"Metoda Rogi","techniques":["Metoda Rogi"],"technique_en":"Roga method","computed":[],"computed_en":[],"activity":"Zdolność spiekania\nZakres 1 – 90\nMetoda Rogi","reference":"PN-G-04508:2020-05","norm_bases":["PN-G-04508:2020-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zdolność spiekania\nZakres 1 – 90\nMetoda Rogi PN-G-04508:2020-05 Paliwa stale: wegiel kamienny Zdolnosc spiekania\nZakres 1 – 90\nMetoda Rogi PN-G-04508:2020-05","categories":["petro"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Caking ability Roga method Range PN-G-04508:2020-05","parameters_zh":[{"name":"范围","range":"1 – 90"}],"search_zh":"固体燃料：烟煤 黏结性 罗加法（Roga） 范围 PN-G-04508:2020-05","test_object_zh":"固体燃料：烟煤","methodology_zh":"黏结性","technique_zh":"罗加法（Roga）"},{"_id":"6a5dc9c5f1c10c8ce82603b7","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(1,0 – 30,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 30,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (1,0 – 30,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06 z wyłączeniem pkt. 4.4.2; 4.4.4","norm_bases":["PN-G-04611:2020-06 z wyłączeniem pkt. 4.4.2; 4.4.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej\nZakres (1,0 – 30,0) %\nMetoda wagowa PN-G-04611:2020-06 z wyłączeniem pkt. 4.4.2; 4.4.4 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej\nZakres (1,0 – 30,0) %\nMetoda wagowa PN-G-04611:2020-06 z wylaczeniem pkt. 4.4.2; 4.4.4","categories":["petro"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Total moisture content Gravimetric method Range PN-G-04611:2020-06 z wyłączeniem pkt. 4.4.2; 4.4.4","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 30,0) %"}],"search_zh":"固体燃料：烟煤 全水分含量 重量法 范围 PN-G-04611:2020-06 z wyłączeniem pkt. 4.4.2; 4.4.4","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c5f1c10c8ce82603b8","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość części lotnych","methodology_en":"Volatile matter content","parameters":[{"name":"Zakres","range":"(3,0 – 37,0) %"}],"parameters_en":[{"name":"Range","range":"(3,0 – 37,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość części lotnych\nZakres (3,0 – 37,0) %\nMetoda wagowa","reference":"ISO 562:2024","norm_bases":["ISO 562:2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość części lotnych\nZakres (3,0 – 37,0) %\nMetoda wagowa ISO 562:2024 Paliwa stale: wegiel kamienny Zawartosc czesci lotnych\nZakres (3,0 – 37,0) %\nMetoda wagowa ISO 562:2024","categories":["petro"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Volatile matter content Gravimetric method Range ISO 562:2024","parameters_zh":[{"name":"范围","range":"(3,0 – 37,0) %"}],"search_zh":"固体燃料：烟煤 挥发分含量 重量法 范围 ISO 562:2024","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"挥发分含量"},{"_id":"6a5dc9c5f1c10c8ce82603b9","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Wskaźnik fixed carbon (z obliczeń)","methodology_en":"Fixed carbon index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik fixed carbon (z obliczeń)","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Wskaźnik fixed carbon (z obliczeń) PN-G-04516:1998 Paliwa stale: wegiel kamienny Wskaznik fixed carbon (z obliczen) PN-G-04516:1998","categories":["petro"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Fixed carbon index (calculated) PN-G-04516:1998","search_zh":"固体燃料：烟煤 固定碳指标（由计算得出） PN-G-04516:1998","test_object_zh":"固体燃料：烟煤","methodology_zh":"固定碳指标（由计算得出）"},{"_id":"6a5dc9c5f1c10c8ce82603ba","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Wskaźnik emisji CO2 (z obliczeń)","methodology_en":"CO2 emission factor (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik emisji CO2 (z obliczeń)","reference":"PB-01 wyd.3 z 22.08.2024","norm_bases":["PB-01 wyd.3 z 22.08.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Wskaźnik emisji CO2 (z obliczeń) PB-01 wyd.3 z 22.08.2024 Paliwa stale: wegiel kamienny Wskaznik emisji CO2 (z obliczen) PB-01 wyd.3 z 22.08.2024","categories":["environment","petro"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal CO2 emission factor (calculated) PB-01 wyd.3 z 22.08.2024","search_zh":"固体燃料：烟煤 PB-01 wyd.3 z 22.08.2024","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c5f1c10c8ce82603bb","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Współczynnik utleniania (z obliczeń)","methodology_en":"Oxidation coefficient (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik utleniania (z obliczeń)","reference":"PB-01 wyd.3 z 22.08.2024","norm_bases":["PB-01 wyd.3 z 22.08.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Współczynnik utleniania (z obliczeń) PB-01 wyd.3 z 22.08.2024 Paliwa stale: wegiel kamienny Wspolczynnik utleniania (z obliczen) PB-01 wyd.3 z 22.08.2024","categories":["petro"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Oxidation coefficient (calculated) PB-01 wyd.3 z 22.08.2024","search_zh":"固体燃料：烟煤 PB-01 wyd.3 z 22.08.2024","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c5f1c10c8ce82603bc","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: koks","test_object_en":"Solid fuels: coke","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(0,1 – 30,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 30,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (0,1 – 30,0) %\nMetoda wagowa","reference":"PN-ISO 579:2002 | PN-G-04611:2020-06 z wyłączeniem pkt. 4.4.2; 4.4.4","norm_bases":["PN-ISO 579:2002","PN-G-04611:2020-06 z wyłączeniem pkt. 4.4.2; 4.4.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: koks Zawartość wilgoci całkowitej\nZakres (0,1 – 30,0) %\nMetoda wagowa PN-ISO 579:2002 | PN-G-04611:2020-06 z wyłączeniem pkt. 4.4.2; 4.4.4 Paliwa stale: koks Zawartosc wilgoci calkowitej\nZakres (0,1 – 30,0) %\nMetoda wagowa PN-ISO 579:2002 | PN-G-04611:2020-06 z wylaczeniem pkt. 4.4.2; 4.4.4","categories":["petro"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: coke Total moisture content Gravimetric method Range PN-ISO 579:2002 | PN-G-04611:2020-06 z wyłączeniem pkt. 4.4.2; 4.4.4","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 30,0) %"}],"search_zh":"固体燃料：焦炭 全水分含量 重量法 范围 PN-ISO 579:2002 | PN-G-04611:2020-06 z wyłączeniem pkt. 4.4.2; 4.4.4","technique_zh":"重量法","test_object_zh":"固体燃料：焦炭"},{"_id":"6a5dc9c5f1c10c8ce82603bd","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: koks","test_object_en":"Solid fuels: coke","methodology":"Zawartość wilgoci w próbce analitycznej","methodology_en":"Moisture content in the analytical sample","parameters":[{"name":"Zakres","range":"(0,1 – 10,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 10,0) %\nMetoda wagowa","reference":"PN-ISO 687:2005","norm_bases":["PN-ISO 687:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: koks Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 10,0) %\nMetoda wagowa PN-ISO 687:2005 Paliwa stale: koks Zawartosc wilgoci w probce analitycznej\nZakres (0,1 – 10,0) %\nMetoda wagowa PN-ISO 687:2005","categories":["petro"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: coke Moisture content in the analytical sample Gravimetric method Range PN-ISO 687:2005","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 10,0) %"}],"search_zh":"固体燃料：焦炭 分析样品水分含量 重量法 范围 PN-ISO 687:2005","technique_zh":"重量法","test_object_zh":"固体燃料：焦炭"},{"_id":"6a5dc9c5f1c10c8ce82603be","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: koks","test_object_en":"Solid fuels: coke","methodology":"Zawartość części lotnych","methodology_en":"Volatile matter content","parameters":[{"name":"Zakres","range":"(1,0 – 20,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 20,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość części lotnych\nZakres (1,0 – 20,0) %\nMetoda wagowa","reference":"ISO 562:2024","norm_bases":["ISO 562:2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: koks Zawartość części lotnych\nZakres (1,0 – 20,0) %\nMetoda wagowa ISO 562:2024 Paliwa stale: koks Zawartosc czesci lotnych\nZakres (1,0 – 20,0) %\nMetoda wagowa ISO 562:2024","categories":["petro"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: coke Volatile matter content Gravimetric method Range ISO 562:2024","parameters_zh":[{"name":"范围","range":"(1,0 – 20,0) %"}],"search_zh":"固体燃料：焦炭 挥发分含量 重量法 范围 ISO 562:2024","technique_zh":"重量法","methodology_zh":"挥发分含量","test_object_zh":"固体燃料：焦炭"},{"_id":"6a5dc9c5f1c10c8ce82603bf","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny i koks","test_object_en":"Solid fuels: hard coal and coke","methodology":"Zawartość wilgoci w próbce analitycznej","methodology_en":"Moisture content in the analytical sample","parameters":[{"name":"Zakres","range":"(0,1 – 10,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 10,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-0606 z wyłączeniem pkt. 4.3.1.3.2","norm_bases":["PN-G-04611:2020-0606 z wyłączeniem pkt. 4.3.1.3.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny i koks Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 10,0) %\nMetoda wagowa PN-G-04611:2020-0606 z wyłączeniem pkt. 4.3.1.3.2 Paliwa stale: wegiel kamienny i koks Zawartosc wilgoci w probce analitycznej\nZakres (0,1 – 10,0) %\nMetoda wagowa PN-G-04611:2020-0606 z wylaczeniem pkt. 4.3.1.3.2","categories":["petro"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal and coke Moisture content in the analytical sample Gravimetric method Range PN-G-04611:2020-0606 z wyłączeniem pkt. 4.3.1.3.2","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 10,0) %"}],"search_zh":"固体燃料：烟煤与焦炭 分析样品水分含量 重量法 范围 PN-G-04611:2020-0606 z wyłączeniem pkt. 4.3.1.3.2","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤与焦炭"},{"_id":"6a5dc9c5f1c10c8ce82603c0","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny i koks","test_object_en":"Solid fuels: hard coal and coke","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(0,5 – 50,0) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 50,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (0,5 – 50,0) %\nMetoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny i koks Zawartość popiołu\nZakres (0,5 – 50,0) %\nMetoda wagowa PN-ISO 1171:2002 Paliwa stale: wegiel kamienny i koks Zawartosc popiolu\nZakres (0,5 – 50,0) %\nMetoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal and coke Ash content Gravimetric method Range PN-ISO 1171:2002","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,5 – 50,0) %"}],"search_zh":"固体燃料：烟煤与焦炭 灰分含量 重量法 范围 PN-ISO 1171:2002","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤与焦炭"},{"_id":"6a5dc9c5f1c10c8ce82603c1","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny i koks","test_object_en":"Solid fuels: hard coal and coke","methodology":"Zawartość wilgoci w próbce analitycznej","methodology_en":"Moisture content in the analytical sample","parameters":[{"name":"Zakres","range":"(0,20 – 10,00) %"}],"parameters_en":[{"name":"Range","range":"(0,20 – 10,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,20 – 10,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny i koks Zawartość wilgoci w próbce analitycznej\nZakres (0,20 – 10,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny i koks Zawartosc wilgoci w probce analitycznej\nZakres (0,20 – 10,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal and coke Moisture content in the analytical sample Thermogravimetric method (TGA) Range PN-G-04560:1998","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,20 – 10,00) %"}],"search_zh":"固体燃料：烟煤与焦炭 分析样品水分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤与焦炭"},{"_id":"6a5dc9c5f1c10c8ce82603c2","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny i koks","test_object_en":"Solid fuels: hard coal and coke","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(0,10 – 50,00) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 50,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (0,10 – 50,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny i koks Zawartość popiołu\nZakres (0,10 – 50,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny i koks Zawartosc popiolu\nZakres (0,10 – 50,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal and coke Ash content Thermogravimetric method (TGA) Range PN-G-04560:1998","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,10 – 50,00) %"}],"search_zh":"固体燃料：烟煤与焦炭 灰分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤与焦炭"},{"_id":"6a5dc9c5f1c10c8ce82603c3","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny i koks","test_object_en":"Solid fuels: hard coal and coke","methodology":"Ciepło spalania","methodology_en":"Gross calorific value","parameters":[{"name":"Zakres","range":"(10000 – 35000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(10000 – 35000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"technique_en":"Calorimetric method","computed":[],"computed_en":[],"activity":"Ciepło spalania\nZakres:\nZakres (10000 – 35000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny i koks Ciepło spalania\nZakres:\nZakres (10000 – 35000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny i koks Cieplo spalania\nZakres:\nZakres (10000 – 35000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-ISO 1928:2020-05","categories":["petro"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal and coke Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-ISO 1928:2020-05","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(10000 – 35000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：烟煤与焦炭 高位发热量 量热法 范围 低位发热量（计算值） PN-ISO 1928:2020-05","technique_zh":"量热法","test_object_zh":"固体燃料：烟煤与焦炭"},{"_id":"6a5dc9c5f1c10c8ce82603c4","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny i koks","test_object_en":"Solid fuels: hard coal and coke","methodology":"Zawartość siarki całkowitej","methodology_en":"Total sulfur content","parameters":[{"name":"Zakres","range":"(0,10 – 3,00) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 3,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej\nZakres (0,10 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001 | ISO 19579:2006","norm_bases":["PN-G-04584:2001","ISO 19579:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny i koks Zawartość siarki całkowitej\nZakres (0,10 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 | ISO 19579:2006 Paliwa stale: wegiel kamienny i koks Zawartosc siarki calkowitej\nZakres (0,10 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001 | ISO 19579:2006","categories":["petro"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal and coke Total sulfur content High-temperature combustion with IR detection Range PN-G-04584:2001 | ISO 19579:2006","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,10 – 3,00) %"}],"search_zh":"固体燃料：烟煤与焦炭 全硫含量 高温燃烧红外检测法 范围 PN-G-04584:2001 | ISO 19579:2006","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤与焦炭"},{"_id":"6a5dc9c5f1c10c8ce82603c5","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny i koks","test_object_en":"Solid fuels: hard coal and coke","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(38,0 – 96,0) %"}],"parameters_en":[{"name":"Range","range":"(38,0 – 96,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres (38,0 – 96,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998 PKN-ISO/TS 12902:2007","norm_bases":["PN-G-04571:1998 PKN-ISO/TS 12902:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny i koks Zawartość węgla całkowitego\nZakres (38,0 – 96,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 PKN-ISO/TS 12902:2007 Paliwa stale: wegiel kamienny i koks Zawartosc wegla calkowitego\nZakres (38,0 – 96,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998 PKN-ISO/TS 12902:2007","categories":["petro"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal and coke Total carbon content High-temperature combustion with IR detection Range PN-G-04571:1998 PKN-ISO/TS 12902:2007","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(38,0 – 96,0) %"}],"search_zh":"固体燃料：烟煤与焦炭 总碳含量 高温燃烧红外检测法 范围 PN-G-04571:1998 PKN-ISO/TS 12902:2007","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤与焦炭"},{"_id":"6a5dc9c5f1c10c8ce82603c6","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny i koks","test_object_en":"Solid fuels: hard coal and coke","methodology":"Zawartość wodoru","methodology_en":"Hydrogen content","parameters":[{"name":"Zakres","range":"(0,25 – 6,00) %"}],"parameters_en":[{"name":"Range","range":"(0,25 – 6,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość wodoru\nZakres (0,25 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998 PKN-ISO/TS 12902:2007","norm_bases":["PN-G-04571:1998 PKN-ISO/TS 12902:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny i koks Zawartość wodoru\nZakres (0,25 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 PKN-ISO/TS 12902:2007 Paliwa stale: wegiel kamienny i koks Zawartosc wodoru\nZakres (0,25 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998 PKN-ISO/TS 12902:2007","categories":["petro"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal and coke Hydrogen content High-temperature combustion with IR detection Range PN-G-04571:1998 PKN-ISO/TS 12902:2007","parameters_zh":[{"name":"范围","range":"(0,25 – 6,00) %"}],"search_zh":"固体燃料：烟煤与焦炭 氢含量 高温燃烧红外检测法 范围 PN-G-04571:1998 PKN-ISO/TS 12902:2007","technique_zh":"高温燃烧红外检测法","methodology_zh":"氢含量","test_object_zh":"固体燃料：烟煤与焦炭"},{"_id":"6a5dc9c5f1c10c8ce82603c7","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny i koks","test_object_en":"Solid fuels: hard coal and coke","methodology":"Zawartość azotu","methodology_en":"Nitrogen content","parameters":[{"name":"Zakres","range":"(0,10 – 2,00) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 2,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"technique_en":"High-temperature combustion with TC detection","computed":[],"computed_en":[],"activity":"Zawartość azotu\nZakres (0,10 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-G-04571:1998 PKN-ISO/TS 12902:2007","norm_bases":["PN-G-04571:1998 PKN-ISO/TS 12902:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny i koks Zawartość azotu\nZakres (0,10 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-G-04571:1998 PKN-ISO/TS 12902:2007 Paliwa stale: wegiel kamienny i koks Zawartosc azotu\nZakres (0,10 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-G-04571:1998 PKN-ISO/TS 12902:2007","categories":["petro"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal and coke Nitrogen content High-temperature combustion with TC detection Range PN-G-04571:1998 PKN-ISO/TS 12902:2007","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,10 – 2,00) %"}],"search_zh":"固体燃料：烟煤与焦炭 氮含量 高温燃烧总碳检测法 范围 PN-G-04571:1998 PKN-ISO/TS 12902:2007","technique_zh":"高温燃烧总碳检测法","test_object_zh":"固体燃料：烟煤与焦炭"},{"_id":"6a5dc9c5f1c10c8ce82603c8","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny i koks","test_object_en":"Solid fuels: hard coal and coke","methodology":"Zawartość chloru","methodology_en":"Chlorine content","parameters":[{"name":"Zakres","range":"(0,02 – 1,00) %"}],"parameters_en":[{"name":"Range","range":"(0,02 – 1,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość chloru\nZakres (0,02 – 1,00) %\nMetoda miareczkowa","reference":"PN-ISO 587:2000 z wyłączeniem pkt. 7.2.2; 7.2.3","norm_bases":["PN-ISO 587:2000 z wyłączeniem pkt. 7.2.2; 7.2.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny i koks Zawartość chloru\nZakres (0,02 – 1,00) %\nMetoda miareczkowa PN-ISO 587:2000 z wyłączeniem pkt. 7.2.2; 7.2.3 Paliwa stale: wegiel kamienny i koks Zawartosc chloru\nZakres (0,02 – 1,00) %\nMetoda miareczkowa PN-ISO 587:2000 z wylaczeniem pkt. 7.2.2; 7.2.3","categories":["petro"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal and coke Chlorine content Titrimetric method Range PN-ISO 587:2000 z wyłączeniem pkt. 7.2.2; 7.2.3","parameters_zh":[{"name":"范围","range":"(0,02 – 1,00) %"}],"search_zh":"固体燃料：烟煤与焦炭 氯含量 滴定法 范围 PN-ISO 587:2000 z wyłączeniem pkt. 7.2.2; 7.2.3","technique_zh":"滴定法","methodology_zh":"氯含量","test_object_zh":"固体燃料：烟煤与焦炭"},{"_id":"6a5dc9c5f1c10c8ce82603c9","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80","test_object_en":"Waste code: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(0,2 – 40,0) %"}],"parameters_en":[{"name":"Range","range":"(0,2 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (0,2 – 40,0) %\nMetoda wagowa","reference":"CEN/TS 15414-1:2010","norm_bases":["CEN/TS 15414-1:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Zawartość wilgoci całkowitej\nZakres (0,2 – 40,0) %\nMetoda wagowa CEN/TS 15414-1:2010 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Zawartosc wilgoci calkowitej\nZakres (0,2 – 40,0) %\nMetoda wagowa CEN/TS 15414-1:2010","categories":["environment"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Total moisture content Gravimetric method Range CEN/TS 15414-1:2010","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(0,2 – 40,0) %"}],"search_zh":"废物代码：10 01 01、10 01 02、10 01 03、10 01 15、10 01 17、10 01 80 全水分含量 重量法 范围 CEN/TS 15414-1:2010","technique_zh":"重量法","test_object_zh":"废物代码：10 01 01、10 01 02、10 01 03、10 01 15、10 01 17、10 01 80"},{"_id":"6a5dc9c5f1c10c8ce82603ca","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80","test_object_en":"Waste code: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80","methodology":"Zawartość wilgoci w próbce analitycznej","methodology_en":"Moisture content in the analytical sample","parameters":[{"name":"Zakres","range":"(0,1 – 15,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 15,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 15,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 21660-3:2021-08","norm_bases":["PN-EN ISO 21660-3:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 15,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 21660-3:2021-08 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Zawartosc wilgoci w probce analitycznej\nZakres (0,1 – 15,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 21660-3:2021-08","categories":["environment"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Moisture content in the analytical sample Thermogravimetric method (TGA) Range PN-EN ISO 21660-3:2021-08","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 15,0) %"}],"search_zh":"废物代码：10 01 01、10 01 02、10 01 03、10 01 15、10 01 17、10 01 80 分析样品水分含量 热重法（TGA） 范围 PN-EN ISO 21660-3:2021-08","technique_zh":"热重法（TGA）","test_object_zh":"废物代码：10 01 01、10 01 02、10 01 03、10 01 15、10 01 17、10 01 80"},{"_id":"6a5dc9c5f1c10c8ce82603cb","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80","test_object_en":"Waste code: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(40,0 – 95,0) %"}],"parameters_en":[{"name":"Range","range":"(40,0 – 95,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (40,0 – 95,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 21656:2021-08 z wyłączeniem metody A","norm_bases":["PN-EN ISO 21656:2021-08 z wyłączeniem metody A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Zawartość popiołu\nZakres (40,0 – 95,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 21656:2021-08 z wyłączeniem metody A Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Zawartosc popiolu\nZakres (40,0 – 95,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 21656:2021-08 z wylaczeniem metody A","categories":["environment"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Ash content Thermogravimetric method (TGA) Range PN-EN ISO 21656:2021-08 z wyłączeniem metody A","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(40,0 – 95,0) %"}],"search_zh":"废物代码：10 01 01、10 01 02、10 01 03、10 01 15、10 01 17、10 01 80 灰分含量 热重法（TGA） 范围 PN-EN ISO 21656:2021-08 z wyłączeniem metody A","technique_zh":"热重法（TGA）","test_object_zh":"废物代码：10 01 01、10 01 02、10 01 03、10 01 15、10 01 17、10 01 80"},{"_id":"6a5dc9c5f1c10c8ce82603cc","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80","test_object_en":"Waste code: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(0,1 – 40,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 40,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres (0,1 – 40,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Zawartość węgla całkowitego\nZakres (0,1 – 40,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 21663:2021-06 Odpady kod: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Zawartosc wegla calkowitego\nZakres (0,1 – 40,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 21663:2021-06","categories":["environment"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 10 01 01, 10 01 02, 10 01 03, 10 01 15, 10 01 17, 10 01 80 Total carbon content High-temperature combustion with IR detection Range PN-EN ISO 21663:2021-06","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(0,1 – 40,0) %"}],"search_zh":"废物代码：10 01 01、10 01 02、10 01 03、10 01 15、10 01 17、10 01 80 总碳含量 高温燃烧红外检测法 范围 PN-EN ISO 21663:2021-06","technique_zh":"高温燃烧红外检测法","test_object_zh":"废物代码：10 01 01、10 01 02、10 01 03、10 01 15、10 01 17、10 01 80"},{"_id":"6a5dc9c5f1c10c8ce82603cd","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10","test_object_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(1,0 – 50,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 50,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (1,0 – 50,0) %\nMetoda wagowa","reference":"CEN/TS 15414-1:2010","norm_bases":["CEN/TS 15414-1:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10 Zawartość wilgoci całkowitej\nZakres (1,0 – 50,0) %\nMetoda wagowa CEN/TS 15414-1:2010 Paliwa stale: stale paliwo wtorne (SRF), Odpady kod: 19 12 10 Zawartosc wilgoci calkowitej\nZakres (1,0 – 50,0) %\nMetoda wagowa CEN/TS 15414-1:2010","categories":["environment","petro"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10 Total moisture content Gravimetric method Range CEN/TS 15414-1:2010","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 50,0) %"}],"search_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10 全水分含量 重量法 范围 CEN/TS 15414-1:2010","technique_zh":"重量法","test_object_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10"},{"_id":"6a5dc9c5f1c10c8ce82603ce","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10","test_object_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10","methodology":"Zawartość wilgoci w próbce analitycznej","methodology_en":"Moisture content in the analytical sample","parameters":[{"name":"Zakres","range":"(0,1 – 15,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 15,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 15,0) %\nMetoda wagowa","reference":"PN-EN ISO 21660-3:2021-08","norm_bases":["PN-EN ISO 21660-3:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10 Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 15,0) %\nMetoda wagowa PN-EN ISO 21660-3:2021-08 Paliwa stale: stale paliwo wtorne (SRF), Odpady kod: 19 12 10 Zawartosc wilgoci w probce analitycznej\nZakres (0,1 – 15,0) %\nMetoda wagowa PN-EN ISO 21660-3:2021-08","categories":["environment","petro"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10 Moisture content in the analytical sample Gravimetric method Range PN-EN ISO 21660-3:2021-08","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 15,0) %"}],"search_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10 分析样品水分含量 重量法 范围 PN-EN ISO 21660-3:2021-08","technique_zh":"重量法","test_object_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10"},{"_id":"6a5dc9c5f1c10c8ce82603cf","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10","test_object_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10","methodology":"Zawartość wilgoci w próbce analitycznej","methodology_en":"Moisture content in the analytical sample","parameters":[{"name":"Zakres","range":"(0,1 – 15,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 15,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 15,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 21660-3:2021-08","norm_bases":["PN-EN ISO 21660-3:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10 Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 15,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 21660-3:2021-08 Paliwa stale: stale paliwo wtorne (SRF), Odpady kod: 19 12 10 Zawartosc wilgoci w probce analitycznej\nZakres (0,1 – 15,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 21660-3:2021-08","categories":["environment","petro"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10 Moisture content in the analytical sample Thermogravimetric method (TGA) Range PN-EN ISO 21660-3:2021-08","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 15,0) %"}],"search_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10 分析样品水分含量 热重法（TGA） 范围 PN-EN ISO 21660-3:2021-08","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10"},{"_id":"6a5dc9c5f1c10c8ce82603d0","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10","test_object_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(0,5 – 40,0) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 40,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (0,5 – 40,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 21656:2021-08 z wyłączeniem metody A","norm_bases":["PN-EN ISO 21656:2021-08 z wyłączeniem metody A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10 Zawartość popiołu\nZakres (0,5 – 40,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 21656:2021-08 z wyłączeniem metody A Paliwa stale: stale paliwo wtorne (SRF), Odpady kod: 19 12 10 Zawartosc popiolu\nZakres (0,5 – 40,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 21656:2021-08 z wylaczeniem metody A","categories":["environment","petro"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10 Ash content Thermogravimetric method (TGA) Range PN-EN ISO 21656:2021-08 z wyłączeniem metody A","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,5 – 40,0) %"}],"search_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10 灰分含量 热重法（TGA） 范围 PN-EN ISO 21656:2021-08 z wyłączeniem metody A","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10"},{"_id":"6a5dc9c5f1c10c8ce82603d1","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10","test_object_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(0,5 – 40,0) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (0,5 – 40,0) %\nMetoda wagowa","reference":"PN-EN ISO 21656:2021-08 z wyłączeniem metody A","norm_bases":["PN-EN ISO 21656:2021-08 z wyłączeniem metody A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10 Zawartość popiołu\nZakres (0,5 – 40,0) %\nMetoda wagowa PN-EN ISO 21656:2021-08 z wyłączeniem metody A Paliwa stale: stale paliwo wtorne (SRF), Odpady kod: 19 12 10 Zawartosc popiolu\nZakres (0,5 – 40,0) %\nMetoda wagowa PN-EN ISO 21656:2021-08 z wylaczeniem metody A","categories":["environment","petro"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10 Ash content Gravimetric method Range PN-EN ISO 21656:2021-08 z wyłączeniem metody A","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,5 – 40,0) %"}],"search_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10 灰分含量 重量法 范围 PN-EN ISO 21656:2021-08 z wyłączeniem metody A","technique_zh":"重量法","test_object_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10"},{"_id":"6a5dc9c5f1c10c8ce82603d2","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10","test_object_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10","methodology":"Zawartość części lotnych","methodology_en":"Volatile matter content","parameters":[{"name":"Zakres","range":"(50,0 – 70,0) %"}],"parameters_en":[{"name":"Range","range":"(50,0 – 70,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość części lotnych\nZakres (50,0 – 70,0) %\nMetoda wagowa","reference":"PN-EN ISO 22167:2021-08","norm_bases":["PN-EN ISO 22167:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10 Zawartość części lotnych\nZakres (50,0 – 70,0) %\nMetoda wagowa PN-EN ISO 22167:2021-08 Paliwa stale: stale paliwo wtorne (SRF), Odpady kod: 19 12 10 Zawartosc czesci lotnych\nZakres (50,0 – 70,0) %\nMetoda wagowa PN-EN ISO 22167:2021-08","categories":["environment","petro"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10 Volatile matter content Gravimetric method Range PN-EN ISO 22167:2021-08","parameters_zh":[{"name":"范围","range":"(50,0 – 70,0) %"}],"search_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10 挥发分含量 重量法 范围 PN-EN ISO 22167:2021-08","technique_zh":"重量法","methodology_zh":"挥发分含量","test_object_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10"},{"_id":"6a5dc9c5f1c10c8ce82603d3","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10","test_object_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10","methodology":"Ciepło spalania","methodology_en":"Gross calorific value","parameters":[{"name":"Zakres","range":"(7000 – 40000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(7000 – 40000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"technique_en":"Calorimetric method","computed":[],"computed_en":[],"activity":"Ciepło spalania\nZakres:\nZakres (7000 – 40000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10 Ciepło spalania\nZakres:\nZakres (7000 – 40000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12 Paliwa stale: stale paliwo wtorne (SRF), Odpady kod: 19 12 10 Cieplo spalania\nZakres:\nZakres (7000 – 40000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12","categories":["environment","petro"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10 Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-EN ISO 21654:2021-12","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(7000 – 40000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10 高位发热量 量热法 范围 低位发热量（计算值） PN-EN ISO 21654:2021-12","technique_zh":"量热法","test_object_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10"},{"_id":"6a5dc9c5f1c10c8ce82603d4","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10","test_object_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10","methodology":"Zawartość siarki całkowitej","methodology_en":"Total sulfur content","parameters":[{"name":"Zakres","range":"(0,10 – 2,00) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 2,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej\nZakres (0,10 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 15408:2011","norm_bases":["PN-EN 15408:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10 Zawartość siarki całkowitej\nZakres (0,10 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 15408:2011 Paliwa stale: stale paliwo wtorne (SRF), Odpady kod: 19 12 10 Zawartosc siarki calkowitej\nZakres (0,10 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 15408:2011","categories":["environment","petro"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10 Total sulfur content High-temperature combustion with IR detection Range PN-EN 15408:2011","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,10 – 2,00) %"}],"search_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10 全硫含量 高温燃烧红外检测法 范围 PN-EN 15408:2011","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10"},{"_id":"6a5dc9c5f1c10c8ce82603d5","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10","test_object_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(20,0 – 80,0) %"}],"parameters_en":[{"name":"Range","range":"(20,0 – 80,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres (20,0 – 80,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10 Zawartość węgla całkowitego\nZakres (20,0 – 80,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 21663:2021-06 Paliwa stale: stale paliwo wtorne (SRF), Odpady kod: 19 12 10 Zawartosc wegla calkowitego\nZakres (20,0 – 80,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 21663:2021-06","categories":["environment","petro"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10 Total carbon content High-temperature combustion with IR detection Range PN-EN ISO 21663:2021-06","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(20,0 – 80,0) %"}],"search_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10 总碳含量 高温燃烧红外检测法 范围 PN-EN ISO 21663:2021-06","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10"},{"_id":"6a5dc9c5f1c10c8ce82603d6","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10","test_object_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10","methodology":"Zawartość wodoru","methodology_en":"Hydrogen content","parameters":[{"name":"Zakres","range":"(1,00 – 10,0) %"}],"parameters_en":[{"name":"Range","range":"(1,00 – 10,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość wodoru\nZakres (1,00 – 10,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10 Zawartość wodoru\nZakres (1,00 – 10,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 21663:2021-06 Paliwa stale: stale paliwo wtorne (SRF), Odpady kod: 19 12 10 Zawartosc wodoru\nZakres (1,00 – 10,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 21663:2021-06","categories":["environment","petro"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10 Hydrogen content High-temperature combustion with IR detection Range PN-EN ISO 21663:2021-06","parameters_zh":[{"name":"范围","range":"(1,00 – 10,0) %"}],"search_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10 氢含量 高温燃烧红外检测法 范围 PN-EN ISO 21663:2021-06","technique_zh":"高温燃烧红外检测法","methodology_zh":"氢含量","test_object_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10"},{"_id":"6a5dc9c5f1c10c8ce82603d7","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10","test_object_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10","methodology":"Zawartość azotu","methodology_en":"Nitrogen content","parameters":[{"name":"Zakres","range":"(0,10 – 1,00) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 1,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"technique_en":"High-temperature combustion with TC detection","computed":[],"computed_en":[],"activity":"Zawartość azotu\nZakres (0,10 – 1,00) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10 Zawartość azotu\nZakres (0,10 – 1,00) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-EN ISO 21663:2021-06 Paliwa stale: stale paliwo wtorne (SRF), Odpady kod: 19 12 10 Zawartosc azotu\nZakres (0,10 – 1,00) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-EN ISO 21663:2021-06","categories":["environment","petro"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10 Nitrogen content High-temperature combustion with TC detection Range PN-EN ISO 21663:2021-06","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,10 – 1,00) %"}],"search_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10 氮含量 高温燃烧总碳检测法 范围 PN-EN ISO 21663:2021-06","technique_zh":"高温燃烧总碳检测法","test_object_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10"},{"_id":"6a5dc9c5f1c10c8ce82603d8","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10","test_object_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10","methodology":"Zawartość chloru","methodology_en":"Chlorine content","parameters":[{"name":"Zakres","range":"(0,02 – 5,00) %"}],"parameters_en":[{"name":"Range","range":"(0,02 – 5,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość chloru\nZakres (0,02 – 5,00) %\nMetoda miareczkowa","reference":"PN-ISO 587:2000 z wyłączeniem pkt. 7.2.2; 7.2.3","norm_bases":["PN-ISO 587:2000 z wyłączeniem pkt. 7.2.2; 7.2.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady kod: 19 12 10 Zawartość chloru\nZakres (0,02 – 5,00) %\nMetoda miareczkowa PN-ISO 587:2000 z wyłączeniem pkt. 7.2.2; 7.2.3 Paliwa stale: stale paliwo wtorne (SRF), Odpady kod: 19 12 10 Zawartosc chloru\nZakres (0,02 – 5,00) %\nMetoda miareczkowa PN-ISO 587:2000 z wylaczeniem pkt. 7.2.2; 7.2.3","categories":["environment","petro"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid recovered fuel (SRF), Waste code: 19 12 10 Chlorine content Titrimetric method Range PN-ISO 587:2000 z wyłączeniem pkt. 7.2.2; 7.2.3","parameters_zh":[{"name":"范围","range":"(0,02 – 5,00) %"}],"search_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10 氯含量 滴定法 范围 PN-ISO 587:2000 z wyłączeniem pkt. 7.2.2; 7.2.3","technique_zh":"滴定法","methodology_zh":"氯含量","test_object_zh":"固体燃料：固体再生燃料（SRF），废物代码：19 12 10"},{"_id":"6a5dc9c5f1c10c8ce82603d9","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(1,0 – 30,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 30,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (1,0 – 30,0) %\nMetoda wagowa","reference":"PN-EN ISO 18134-2:2024-10","norm_bases":["PN-EN ISO 18134-2:2024-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość wilgoci całkowitej\nZakres (1,0 – 30,0) %\nMetoda wagowa PN-EN ISO 18134-2:2024-10 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wilgoci calkowitej\nZakres (1,0 – 30,0) %\nMetoda wagowa PN-EN ISO 18134-2:2024-10","categories":["petro"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Total moisture content Gravimetric method Range PN-EN ISO 18134-2:2024-10","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 30,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 全水分含量 重量法 范围 PN-EN ISO 18134-2:2024-10","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a5dc9c5f1c10c8ce82603da","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość wilgoci w próbce analitycznej","methodology_en":"Moisture content in the analytical sample","parameters":[{"name":"Zakres","range":"(1,0 – 25,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 25,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 25,0) %\nMetoda wagowa","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 25,0) %\nMetoda wagowa PN-EN ISO 18134-3:2023-12 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wilgoci w probce analitycznej\nZakres (1,0 – 25,0) %\nMetoda wagowa PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Moisture content in the analytical sample Gravimetric method Range PN-EN ISO 18134-3:2023-12","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 25,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 分析样品水分含量 重量法 范围 PN-EN ISO 18134-3:2023-12","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a5dc9c5f1c10c8ce82603db","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość wilgoci w próbce analitycznej","methodology_en":"Moisture content in the analytical sample","parameters":[{"name":"Zakres","range":"(1,0 – 25,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 25,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 25,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 25,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18134-3:2023-12 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wilgoci w probce analitycznej\nZakres (1,0 – 25,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Moisture content in the analytical sample Thermogravimetric method (TGA) Range PN-EN ISO 18134-3:2023-12","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 25,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 分析样品水分含量 热重法（TGA） 范围 PN-EN ISO 18134-3:2023-12","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a5dc9c5f1c10c8ce82603dc","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(0,1 – 50,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 50,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (0,1 – 50,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 18122:2023-05","norm_bases":["PN-EN ISO 18122:2023-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość popiołu\nZakres (0,1 – 50,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18122:2023-05 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc popiolu\nZakres (0,1 – 50,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18122:2023-05","categories":["petro"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Ash content Thermogravimetric method (TGA) Range PN-EN ISO 18122:2023-05","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 50,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 灰分含量 热重法（TGA） 范围 PN-EN ISO 18122:2023-05","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a5dc9c5f1c10c8ce82603dd","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(0,1 – 50,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 50,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (0,1 – 50,0) %\nMetoda wagowa","reference":"PN-EN ISO 18122:2023-05","norm_bases":["PN-EN ISO 18122:2023-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość popiołu\nZakres (0,1 – 50,0) %\nMetoda wagowa PN-EN ISO 18122:2023-05 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc popiolu\nZakres (0,1 – 50,0) %\nMetoda wagowa PN-EN ISO 18122:2023-05","categories":["petro"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Ash content Gravimetric method Range PN-EN ISO 18122:2023-05","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 50,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 灰分含量 重量法 范围 PN-EN ISO 18122:2023-05","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a5dc9c5f1c10c8ce82603de","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość części lotnych","methodology_en":"Volatile matter content","parameters":[{"name":"Zakres","range":"(60,0 – 80,0) %"}],"parameters_en":[{"name":"Range","range":"(60,0 – 80,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość części lotnych\nZakres (60,0 – 80,0) %\nMetoda wagowa","reference":"PN-EN ISO 18123:2023-10","norm_bases":["PN-EN ISO 18123:2023-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość części lotnych\nZakres (60,0 – 80,0) %\nMetoda wagowa PN-EN ISO 18123:2023-10 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc czesci lotnych\nZakres (60,0 – 80,0) %\nMetoda wagowa PN-EN ISO 18123:2023-10","categories":["petro"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Volatile matter content Gravimetric method Range PN-EN ISO 18123:2023-10","parameters_zh":[{"name":"范围","range":"(60,0 – 80,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 挥发分含量 重量法 范围 PN-EN ISO 18123:2023-10","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","methodology_zh":"挥发分含量"},{"_id":"6a5dc9c5f1c10c8ce82603df","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Ciepło spalania","methodology_en":"Gross calorific value","parameters":[{"name":"Zakres","range":"(5000 – 25000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(5000 – 25000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"technique_en":"Calorimetric method","computed":[],"computed_en":[],"activity":"Ciepło spalania\nZakres:\nZakres (5000 – 25000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-EN ISO 18125:2017-07","norm_bases":["PN-EN ISO 18125:2017-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Ciepło spalania\nZakres:\nZakres (5000 – 25000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07 Paliwa stale: biomasa stala – biopaliwo stale Cieplo spalania\nZakres:\nZakres (5000 – 25000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07","categories":["petro"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-EN ISO 18125:2017-07","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(5000 – 25000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 高位发热量 量热法 范围 低位发热量（计算值） PN-EN ISO 18125:2017-07","technique_zh":"量热法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a5dc9c5f1c10c8ce82603e0","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość siarki całkowitej","methodology_en":"Total sulfur content","parameters":[{"name":"Zakres","range":"(0,02 – 0,20) %"}],"parameters_en":[{"name":"Range","range":"(0,02 – 0,20) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej\nZakres (0,02 – 0,20) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16994:2016-10 z wyłączeniem pkt. 4.2; 4.3","norm_bases":["PN-EN ISO 16994:2016-10 z wyłączeniem pkt. 4.2; 4.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość siarki całkowitej\nZakres (0,02 – 0,20) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16994:2016-10 z wyłączeniem pkt. 4.2; 4.3 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc siarki calkowitej\nZakres (0,02 – 0,20) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16994:2016-10 z wylaczeniem pkt. 4.2; 4.3","categories":["petro"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Total sulfur content High-temperature combustion with IR detection Range PN-EN ISO 16994:2016-10 z wyłączeniem pkt. 4.2; 4.3","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,02 – 0,20) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 全硫含量 高温燃烧红外检测法 范围 PN-EN ISO 16994:2016-10 z wyłączeniem pkt. 4.2; 4.3","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a5dc9c5f1c10c8ce82603e1","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(6,0 – 50,0) %"}],"parameters_en":[{"name":"Range","range":"(6,0 – 50,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres (6,0 – 50,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość węgla całkowitego\nZakres (6,0 – 50,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16948:2015-07 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wegla calkowitego\nZakres (6,0 – 50,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Total carbon content High-temperature combustion with IR detection Range PN-EN ISO 16948:2015-07","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(6,0 – 50,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 总碳含量 高温燃烧红外检测法 范围 PN-EN ISO 16948:2015-07","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a5dc9c5f1c10c8ce82603e2","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość wodoru","methodology_en":"Hydrogen content","parameters":[{"name":"Zakres","range":"(4,00 – 7,30) %"}],"parameters_en":[{"name":"Range","range":"(4,00 – 7,30) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość wodoru\nZakres (4,00 – 7,30) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość wodoru\nZakres (4,00 – 7,30) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16948:2015-07 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wodoru\nZakres (4,00 – 7,30) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Hydrogen content High-temperature combustion with IR detection Range PN-EN ISO 16948:2015-07","parameters_zh":[{"name":"范围","range":"(4,00 – 7,30) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 氢含量 高温燃烧红外检测法 范围 PN-EN ISO 16948:2015-07","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","methodology_zh":"氢含量"},{"_id":"6a5dc9c5f1c10c8ce82603e3","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość azotu","methodology_en":"Nitrogen content","parameters":[{"name":"Zakres","range":"(0,10 – 6,50) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 6,50) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"technique_en":"High-temperature combustion with TC detection","computed":[],"computed_en":[],"activity":"Zawartość azotu\nZakres (0,10 – 6,50) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość azotu\nZakres (0,10 – 6,50) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-EN ISO 16948:2015-07 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc azotu\nZakres (0,10 – 6,50) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Nitrogen content High-temperature combustion with TC detection Range PN-EN ISO 16948:2015-07","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,10 – 6,50) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 氮含量 高温燃烧总碳检测法 范围 PN-EN ISO 16948:2015-07","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","technique_zh":"高温燃烧总碳检测法"},{"_id":"6a5dc9c5f1c10c8ce82603e4","lab_id":"69ad52a3de79e566650fba6b","country":"PL","accr_number":"AB 1913","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość chloru","methodology_en":"Chlorine content","parameters":[{"name":"Zakres","range":"(0,02 – 0,50) %"}],"parameters_en":[{"name":"Range","range":"(0,02 – 0,50) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość chloru\nZakres (0,02 – 0,50) %\nMetoda miareczkowa","reference":"PN-ISO 587:2000 z wyłączeniem pkt. 7.2.2; 7.2.3","norm_bases":["PN-ISO 587:2000 z wyłączeniem pkt. 7.2.2; 7.2.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość chloru\nZakres (0,02 – 0,50) %\nMetoda miareczkowa PN-ISO 587:2000 z wyłączeniem pkt. 7.2.2; 7.2.3 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc chloru\nZakres (0,02 – 0,50) %\nMetoda miareczkowa PN-ISO 587:2000 z wylaczeniem pkt. 7.2.2; 7.2.3","categories":["petro"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Chlorine content Titrimetric method Range PN-ISO 587:2000 z wyłączeniem pkt. 7.2.2; 7.2.3","parameters_zh":[{"name":"范围","range":"(0,02 – 0,50) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 氯含量 滴定法 范围 PN-ISO 587:2000 z wyłączeniem pkt. 7.2.2; 7.2.3","technique_zh":"滴定法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","methodology_zh":"氯含量"}],"has_pdf":true}