{"lab":{"_id":"69ad52a3de79e566650fba5d","accr_number":"AB 1906","country":"PL","accr_body":"PCA","address":"ul. Królewiecka 63/2, 54-117 Wrocław, Laboratorium Badawcze AKULAB Sp. z o.o., ul. Strzegomska 42 AB, lok. 3.07","categories":["environment"],"city":"Wrocław","imported_at":"2026-03-08T10:42:43.265Z","methods_count":9,"name":"AKULAB Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1906.pdf"],"scope_summary":"","search_text":"akulab sp. z o.o. ul. królewiecka 63/2, 54-117 wrocław, laboratorium badawcze akulab sp. z o.o., ul. strzegomska 42 ab, lok. 3.07 environment other metrology","status":"active","updated_at":"2026-03-08T14:51:02.140Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:04:37.589Z","location":{"type":"Point","coordinates":[17.0385,51.1079]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201906,podmiot.html","fields_of_testing":[{"codes":"A/13","pl":"Badania akustyczne maszyn i urządzeń","en":"Acoustic tests of machinery and devices)"},{"codes":"G/33, G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas), środowisko ogólne (czynniki fizyczne – hałas)","en":"Test concerning environmental engineering (enviromental and climatic) – workplace (harmful and nuisance factors – noise), general environment (physical factors – noise)"}],"issue":{"no":"4","date":"14.07.2026"},"parse_date":"2026-08-13T08:04:37.589Z","parse_source":"agent-claude-code","map_coord":[51.147776,16.933375],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium Badawcze AKULAB Sp. z o.o.","address":"ul. Strzegomska 42 AB, lok. 3.07","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/d84b803e6e8a6de2f49b17685591f3bd/AB%201906.pdf","has_en":true,"category_counts":{"environment":9},"category_scores":{"environment":9},"has_zh":true,"lab_locations_zh":[{"name":"AKULAB 检测实验室有限责任公司","address":"ul. Strzegomska 42 AB, lok. 3.07","city":null,"postal":null}]},"methods":[{"_id":"6a7d7a950636ba417e41b6ee","lab_id":"69ad52a3de79e566650fba5d","country":"PL","accr_number":"AB 1906","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 - 137) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(35 - 138) dB"},{"name":"Poziom ekspozycji na hałas odniesiony do:"},{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (24 - 137) dB\nSzczytowy poziom dźwięku C\nZakres (35 - 138) dB\nPoziom ekspozycji na hałas odniesiony do:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11"],"lab_section":"Laboratorium Badawcze AKULAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (24 - 137) dB\nSzczytowy poziom dźwięku C\nZakres (35 - 138) dB\nPoziom ekspozycji na hałas odniesiony do:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (24 - 137) dB\nSzczytowy poziom dzwieku C\nZakres (35 - 138) dB\nPoziom ekspozycji na halas odniesiony do:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen)\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 - punkt 10 i strategie 3 - punkt 11 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 - punkt 10 i strategie 3 - punkt 11","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"AKULAB Sp. z o.o. Testing Laboratory","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(24 - 137) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(35 - 138) dB"},{"name":"Noise exposure level referred to:"},{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method AKULAB Sp. z o.o. Testing Laboratory Range C-weighted peak sound pressure level Range Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(24 - 137) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(35 - 138) dB"},{"name":"噪声暴露级，参照："},{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 AKULAB 检测实验室有限责任公司 范围 C 计权峰值声级 范围 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"AKULAB 检测实验室有限责任公司"},{"_id":"6a7d7a950636ba417e41b6ef","lab_id":"69ad52a3de79e566650fba5d","country":"PL","accr_number":"AB 1906","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od lotnisk","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 - 137) dB"},{"name":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Długookresowy średni poziom dźwięku A wyrażony wskaźnikami LDWN, LN (z obliczeń)"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres:\nZakres (24 - 137) dB\nRównoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Długookresowy średni poziom dźwięku A wyrażony wskaźnikami LDWN, LN (z obliczeń)\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 1 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140, poz. 824) z wyłączeniem punktu H","norm_bases":["Załącznik nr 1 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140, poz. 824) z wyłączeniem punktu H"],"lab_section":"Laboratorium Badawcze AKULAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od lotnisk Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres:\nZakres (24 - 137) dB\nRównoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Długookresowy średni poziom dźwięku A wyrażony wskaźnikami LDWN, LN (z obliczeń)\nMetoda pomiarowa bezpośrednia Załącznik nr 1 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140, poz. 824) z wyłączeniem punktu H Srodowisko ogolne - halas pochodzacy od lotnisk Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A\nZakres:\nZakres (24 - 137) dB\nRownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Dlugookresowy sredni poziom dzwieku A wyrazony wskaznikami LDWN, LN (z obliczen)\nMetoda pomiarowa bezposrednia Zalacznik nr 1 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz.U. Nr 140, poz. 824) z wylaczeniem punktu H","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"AKULAB Sp. z o.o. Testing Laboratory","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(24 - 137) dB"},{"name":"Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Long-term average A-weighted sound level expressed by the indicators LDWN, LN (calculated)"}],"search_en":"General environment - noise from airports A-weighted equivalent sound level A-weighted sound exposure level Direct measurement method AKULAB Sp. z o.o. Testing Laboratory Range Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Long-term average A-weighted sound level expressed by the indicators LDWN, LN (calculated) Załącznik nr 1 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140, poz. 824) z wyłączeniem punktu H","technique_en":"Direct measurement method","test_object_en":"General environment - noise from airports","parameters_zh":[{"name":"范围","range":"(24 - 137) dB"},{"name":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Długookresowy średni poziom dźwięku A wyrażony wskaźnikami LDWN, LN (z obliczeń)"}],"search_zh":"一般环境 － 来自机场的噪声 A 计权等效声级 A 计权声暴露级 直接测量法 AKULAB 检测实验室有限责任公司 范围 Załącznik nr 1 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140, poz. 824) z wyłączeniem punktu H","technique_zh":"直接测量法","methodology_zh":"A 计权等效声级 A 计权声暴露级","lab_section_zh":"AKULAB 检测实验室有限责任公司","test_object_zh":"一般环境 － 来自机场的噪声"},{"_id":"6a7d7a950636ba417e41b6f0","lab_id":"69ad52a3de79e566650fba5d","country":"PL","accr_number":"AB 1906","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od lotnisk","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 - 137) dB"},{"name":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres:\nZakres (24 - 137) dB\nRównoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140, poz. 824) z wyłączeniem punktu H","norm_bases":["Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140, poz. 824) z wyłączeniem punktu H"],"lab_section":"Laboratorium Badawcze AKULAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od lotnisk Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres:\nZakres (24 - 137) dB\nRównoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)\nMetoda pomiarowa bezpośrednia Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140, poz. 824) z wyłączeniem punktu H Srodowisko ogolne - halas pochodzacy od lotnisk Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A\nZakres:\nZakres (24 - 137) dB\nRownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen)\nMetoda pomiarowa bezposrednia Zalacznik nr 2 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz.U. Nr 140, poz. 824) z wylaczeniem punktu H","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"AKULAB Sp. z o.o. Testing Laboratory","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(24 - 137) dB"},{"name":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)"}],"search_en":"General environment - noise from airports A-weighted equivalent sound level A-weighted sound exposure level Direct measurement method AKULAB Sp. z o.o. Testing Laboratory Range A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140, poz. 824) z wyłączeniem punktu H","technique_en":"Direct measurement method","test_object_en":"General environment - noise from airports","parameters_zh":[{"name":"范围","range":"(24 - 137) dB"},{"name":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）"}],"search_zh":"一般环境 － 来自机场的噪声 A 计权等效声级 A 计权声暴露级 直接测量法 AKULAB 检测实验室有限责任公司 范围 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140, poz. 824) z wyłączeniem punktu H","technique_zh":"直接测量法","methodology_zh":"A 计权等效声级 A 计权声暴露级","lab_section_zh":"AKULAB 检测实验室有限责任公司","test_object_zh":"一般环境 － 来自机场的噪声"},{"_id":"6a7d7a950636ba417e41b6f1","lab_id":"69ad52a3de79e566650fba5d","country":"PL","accr_number":"AB 1906","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 - 137) dB"},{"name":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)"}],"technique":"Metoda pomiaru bezpośredniego","techniques":["Metoda pomiaru bezpośredniego"],"computed":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres:\nZakres (24 - 137) dB\nRównoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)\nMetoda pomiaru bezpośredniego","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16 czerwca 2011 r. (Dz. U. Nr 140. poz. 824 i Nr 288 poz. 1697)","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16 czerwca 2011 r. (Dz. U. Nr 140. poz. 824 i Nr 288 poz. 1697)"],"lab_section":"Laboratorium Badawcze AKULAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres:\nZakres (24 - 137) dB\nRównoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)\nMetoda pomiaru bezpośredniego Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16 czerwca 2011 r. (Dz. U. Nr 140. poz. 824 i Nr 288 poz. 1697) Srodowisko ogolne − halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A\nZakres:\nZakres (24 - 137) dB\nRownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen)\nMetoda pomiaru bezposredniego Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16 czerwca 2011 r. (Dz. U. Nr 140. poz. 824 i Nr 288 poz. 1697)","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"AKULAB Sp. z o.o. Testing Laboratory","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(24 - 137) dB"},{"name":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)"}],"search_en":"General environment − noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level Direct measurement method AKULAB Sp. z o.o. Testing Laboratory Range A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16 czerwca 2011 r. (Dz. U. Nr 140. poz. 824 i Nr 288 poz. 1697)","technique_en":"Direct measurement method","test_object_en":"General environment − noise from roads, railway lines, tram lines","parameters_zh":[{"name":"范围","range":"(24 - 137) dB"},{"name":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）"}],"search_zh":"一般环境 − 来自道路、铁路线、有轨电车线的噪声 A 计权等效声级 A 计权声暴露级 直接测量法 AKULAB 检测实验室有限责任公司 范围 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16 czerwca 2011 r. (Dz. U. Nr 140. poz. 824 i Nr 288 poz. 1697)","methodology_zh":"A 计权等效声级 A 计权声暴露级","technique_zh":"直接测量法","test_object_zh":"一般环境 − 来自道路、铁路线、有轨电车线的噪声","lab_section_zh":"AKULAB 检测实验室有限责任公司"},{"_id":"6a7d7a950636ba417e41b6f2","lab_id":"69ad52a3de79e566650fba5d","country":"PL","accr_number":"AB 1906","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN","parameters":[],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN\nMetoda obliczeniowa","reference":"PN ISO 9613-2:2002 NMPB-Routes-2008 Schall 03 RMR/SRM II CNOSSOS-EU:2012 (dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r.. z poźn. zm.)","norm_bases":["PN ISO 9613-2:2002 NMPB-Routes-2008 Schall 03 RMR/SRM II CNOSSOS-EU:2012 (dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r.. z poźn. zm.)"],"lab_section":"Laboratorium Badawcze AKULAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN\nMetoda obliczeniowa PN ISO 9613-2:2002 NMPB-Routes-2008 Schall 03 RMR/SRM II CNOSSOS-EU:2012 (dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r.. z poźn. zm.) Srodowisko ogolne − halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN\nMetoda obliczeniowa PN ISO 9613-2:2002 NMPB-Routes-2008 Schall 03 RMR/SRM II CNOSSOS-EU:2012 (dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r.. z pozn. zm.)","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"AKULAB Sp. z o.o. Testing Laboratory","methodology_en":"Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN","search_en":"General environment − noise from roads, railway lines, tram lines Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN Calculation method AKULAB Sp. z o.o. Testing Laboratory PN ISO 9613-2:2002 NMPB-Routes-2008 Schall 03 RMR/SRM II CNOSSOS-EU:2012 (dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r.. z poźn. zm.)","technique_en":"Calculation method","test_object_en":"General environment − noise from roads, railway lines, tram lines","search_zh":"一般环境 − 来自道路、铁路线、有轨电车线的噪声 以 LAeqD 与 LAeqN 指标表示的参考时段 T 内的 A 计权等效声级 计算法 AKULAB 检测实验室有限责任公司 PN ISO 9613-2:2002 NMPB-Routes-2008 Schall 03 RMR/SRM II CNOSSOS-EU:2012 (dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r.. z poźn. zm.)","technique_zh":"计算法","test_object_zh":"一般环境 − 来自道路、铁路线、有轨电车线的噪声","methodology_zh":"以 LAeqD 与 LAeqN 指标表示的参考时段 T 内的 A 计权等效声级","lab_section_zh":"AKULAB 检测实验室有限责任公司"},{"_id":"6a7d7a950636ba417e41b6f3","lab_id":"69ad52a3de79e566650fba5d","country":"PL","accr_number":"AB 1906","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 - 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (24 - 137) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) | PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.)","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706)","PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.)"],"lab_section":"Laboratorium Badawcze AKULAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (24 - 137) dB\nMetoda pomiarowa bezpośrednia Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) | PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.) Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (24 - 137) dB\nMetoda pomiarowa bezposrednia Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) | PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z pozn. zm.)","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"AKULAB Sp. z o.o. Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(24 - 137) dB"}],"search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method AKULAB Sp. z o.o. Testing Laboratory Range Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) | PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.)","technique_en":"Direct measurement method","test_object_en":"General environment − noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(24 - 137) dB"}],"search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 AKULAB 检测实验室有限责任公司 范围 Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) | PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.)","technique_zh":"直接测量法","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声","lab_section_zh":"AKULAB 检测实验室有限责任公司"},{"_id":"6a7d7a950636ba417e41b6f4","lab_id":"69ad52a3de79e566650fba5d","country":"PL","accr_number":"AB 1906","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) | PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.)","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706)","PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.)"],"lab_section":"Laboratorium Badawcze AKULAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) | PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.) Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) | PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z pozn. zm.)","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"AKULAB Sp. z o.o. Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) AKULAB Sp. z o.o. Testing Laboratory Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) | PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.)","test_object_en":"General environment − noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） AKULAB 检测实验室有限责任公司 Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) | PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.)","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声","lab_section_zh":"AKULAB 检测实验室有限责任公司"},{"_id":"6a7d7a950636ba417e41b6f5","lab_id":"69ad52a3de79e566650fba5d","country":"PL","accr_number":"AB 1906","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN","parameters":[],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN\nMetoda obliczeniowa","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) | PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.)","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706)","PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.)"],"lab_section":"Laboratorium Badawcze AKULAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN\nMetoda obliczeniowa Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) | PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.) Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN\nMetoda obliczeniowa Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) | PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z pozn. zm.)","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"AKULAB Sp. z o.o. Testing Laboratory","methodology_en":"Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN","search_en":"General environment − noise from installations, equipment and industrial plants Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN Calculation method AKULAB Sp. z o.o. Testing Laboratory Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) | PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.)","technique_en":"Calculation method","test_object_en":"General environment − noise from installations, equipment and industrial plants","search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 以 LAeqD 与 LAeqN 指标表示的参考时段 T 内的 A 计权等效声级 计算法 AKULAB 检测实验室有限责任公司 Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) | PN ISO 9613-2:2002 CNOSSOS-EU:2012 (Dyrektywa Komisji UE 2015/996 z dnia 19 maja 2015 r. z późn. zm.)","technique_zh":"计算法","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声","methodology_zh":"以 LAeqD 与 LAeqN 指标表示的参考时段 T 内的 A 计权等效声级","lab_section_zh":"AKULAB 检测实验室有限责任公司"},{"_id":"6a7d7a950636ba417e41b6f6","lab_id":"69ad52a3de79e566650fba5d","country":"PL","accr_number":"AB 1906","accr_body":"PCA","test_object":"Maszyny i urządzenia - hałas","methodology":"Poziom ciśnienia akustycznego","parameters":[{"name":"skorygowany charakterystyką"},{"name":"częstotliwościową A"},{"name":"Zakres","range":"(24 -137) dB"},{"name":"Poziom mocy akustycznej (z obliczeń)"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Poziom ciśnienia akustycznego\nZakres:\nskorygowany charakterystyką\nczęstotliwościową A\nZakres (24 -137) dB\nPoziom mocy akustycznej (z obliczeń)\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 3746:2011 z wyłączeniem punktu 8.4","norm_bases":["PN-EN ISO 3746:2011 z wyłączeniem punktu 8.4"],"lab_section":"Laboratorium Badawcze AKULAB Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia - hałas Poziom ciśnienia akustycznego\nZakres:\nskorygowany charakterystyką\nczęstotliwościową A\nZakres (24 -137) dB\nPoziom mocy akustycznej (z obliczeń)\nMetoda pomiarowa bezpośrednia PN-EN ISO 3746:2011 z wyłączeniem punktu 8.4 Maszyny i urzadzenia - halas Poziom cisnienia akustycznego\nZakres:\nskorygowany charakterystyka\nczestotliwosciowa A\nZakres (24 -137) dB\nPoziom mocy akustycznej (z obliczen)\nMetoda pomiarowa bezposrednia PN-EN ISO 3746:2011 z wylaczeniem punktu 8.4","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"AKULAB Sp. z o.o. Testing Laboratory","methodology_en":"Sound pressure level","parameters_en":[{"name":"weighted with the characteristic"},{"name":"frequency weighting A"},{"name":"Range","range":"(24 -137) dB"},{"name":"Sound power level (calculated)"}],"search_en":"Machinery and equipment - noise Sound pressure level Direct measurement method AKULAB Sp. z o.o. Testing Laboratory weighted with the characteristic frequency weighting A Range Sound power level (calculated) PN-EN ISO 3746:2011 z wyłączeniem punktu 8.4","technique_en":"Direct measurement method","test_object_en":"Machinery and equipment - noise","parameters_zh":[{"name":"按特性计权"},{"name":"A 计权"},{"name":"范围","range":"(24 -137) dB"},{"name":"声功率级（计算值）"}],"search_zh":"机器与设备 — 噪声 声压级 直接测量法 AKULAB 检测实验室有限责任公司 按特性计权 A 计权 范围 声功率级（计算值） PN-EN ISO 3746:2011 z wyłączeniem punktu 8.4","technique_zh":"直接测量法","methodology_zh":"声压级","test_object_zh":"机器与设备 — 噪声","lab_section_zh":"AKULAB 检测实验室有限责任公司"}],"has_pdf":true}