{"lab":{"_id":"69ad52a3de79e566650fba59","country":"PL","accr_number":"AB 1904","accr_body":"PCA","address":"LABORATORIUM BADAWCZE KRZYSZTOF TABIŚ, ul. Stefana Żeromskiego 12, 58-160 Świebodzice","categories":["construction","materials","water"],"city":"Świebodzice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":4,"name":"AQUAPOL POLSKA CPV","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1904.pdf"],"scope_summary":"","search_text":"aquapol polska cpv laboratorium badawcze krzysztof tabiś, ul. stefana żeromskiego 12, 58-160 świebodzice materials construction other water food","status":"active","updated_at":"2026-03-08T14:51:02.020Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:02.020Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201904,podmiot.html","fields_of_testing":[{"codes":"C/5","pl":"Badania chemiczne materiałów budowlanych","en":"Chemical tests of building materials"},{"codes":"N/5","pl":"Badania właściwości fizycznych materiałów budowlanych","en":"Tests of physical properties of building materials"}],"issue":{"no":"2","date":"20.09.2024"},"parse_date":"2026-07-20T07:09:31.465Z","parse_source":"script-pdfplumber","map_coord":[50.85961,16.321601],"map_geo":"nominatim-street","has_en":true,"category_counts":{"construction":4,"materials":4,"water":1},"category_scores":{"construction":1.78,"materials":1.78,"water":0.11},"has_zh":true},"methods":[{"_id":"6a5dc9abf1c10c8ce825a47d","lab_id":"69ad52a3de79e566650fba59","country":"PL","accr_number":"AB 1904","accr_body":"PCA","test_object":"Materiały budowlane - próbki (zwierciny) pobrane z obiektów budowlanych, Building Materials: - samples (drill cuttings) taken","test_object_en":"Building Materials: - samples (drill cuttings) taken","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"azotany","range":"(0,30 - 140) mg/l"},{"name":"chlorki","range":"(0,50 - 100) mg/l"},{"name":"siarczany","range":"(1,00 - 450) mg/l"},{"name":"Zawartość anionów (z obliczeń)"}],"parameters_en":[{"name":"nitrates","range":"(0,30 - 140) mg/l"},{"name":"chlorides","range":"(0,50 - 100) mg/l"},{"name":"sulfates","range":"(1,00 - 450) mg/l"},{"name":"Anion content (calculated)"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nZakres:\nazotany (0,30 - 140) mg/l\nchlorki (0,50 - 100) mg/l\nsiarczany (1,00 - 450) mg/l\nZawartość anionów (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN 16455:2014-12","norm_bases":["PN-EN 16455:2014-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały budowlane - próbki (zwierciny) pobrane z obiektów budowlanych, Building Materials: - samples (drill cuttings) taken Stężenie anionów\nZakres:\nazotany (0,30 - 140) mg/l\nchlorki (0,50 - 100) mg/l\nsiarczany (1,00 - 450) mg/l\nZawartość anionów (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN 16455:2014-12 Materialy budowlane - probki (zwierciny) pobrane z obiektow budowlanych, Building Materials: - samples (drill cuttings) taken Stezenie anionow\nZakres:\nazotany (0,30 - 140) mg/l\nchlorki (0,50 - 100) mg/l\nsiarczany (1,00 - 450) mg/l\nZawartosc anionow (z obliczen)\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN 16455:2014-12","categories":["materials","construction"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Building Materials: - samples (drill cuttings) taken Anion concentrations Ion chromatography with conductometric detection (IC-CD) nitrates chlorides sulfates Anion content (calculated) PN-EN 16455:2014-12","methodology_zh":"阴离子浓度","search_zh":"阴离子浓度 离子色谱-电导检测法（IC-CD） 硝酸盐 氯化物 硫酸盐 阴离子含量（由计算得出） PN-EN 16455:2014-12","technique_zh":"离子色谱-电导检测法（IC-CD）","parameters_zh":[{"name":"硝酸盐","range":"(0,30 - 140) mg/l"},{"name":"氯化物","range":"(0,50 - 100) mg/l"},{"name":"硫酸盐","range":"(1,00 - 450) mg/l"},{"name":"阴离子含量（由计算得出）"}]},{"_id":"6a5dc9abf1c10c8ce825a47e","lab_id":"69ad52a3de79e566650fba59","country":"PL","accr_number":"AB 1904","accr_body":"PCA","test_object":"Materiały budowlane - próbki (zwierciny) pobrane z obiektów budowlanych, Building Materials: - samples (drill cuttings) taken","test_object_en":"Building Materials: - samples (drill cuttings) taken","methodology":"Zawartość wody","methodology_en":"Water content","parameters":[{"name":"Zakres","range":"(1,00 - 10,00) %"},{"name":"Water content"},{"name":"Scope","range":"(1,00 – 10,00) %"},{"name":"Volumetric Karl Fisher titration"}],"parameters_en":[{"name":"Range","range":"(1,00 - 10,00) %"},{"name":"Water content"},{"name":"Scope","range":"(1,00 – 10,00) %"},{"name":"Volumetric Karl Fisher titration"}],"technique":"Metoda miareczkowania wolumetrycznego Karla Fishera (V-KFT)","techniques":["Metoda miareczkowania wolumetrycznego Karla Fishera (V-KFT)"],"technique_en":"Karl Fisher volumetric titration method (V-KFT)","computed":[],"computed_en":[],"activity":"Zawartość wody\nZakres:\nZakres (1,00 - 10,00) %\nWater content\nScope (1,00 – 10,00) %\nVolumetric Karl Fisher titration\nMetoda miareczkowania wolumetrycznego Karla Fishera (V-KFT)","reference":"PN-EN 16682:2017-05","norm_bases":["PN-EN 16682:2017-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały budowlane - próbki (zwierciny) pobrane z obiektów budowlanych, Building Materials: - samples (drill cuttings) taken Zawartość wody\nZakres:\nZakres (1,00 - 10,00) %\nWater content\nScope (1,00 – 10,00) %\nVolumetric Karl Fisher titration\nMetoda miareczkowania wolumetrycznego Karla Fishera (V-KFT) PN-EN 16682:2017-05 Materialy budowlane - probki (zwierciny) pobrane z obiektow budowlanych, Building Materials: - samples (drill cuttings) taken Zawartosc wody\nZakres:\nZakres (1,00 - 10,00) %\nWater content\nScope (1,00 – 10,00) %\nVolumetric Karl Fisher titration\nMetoda miareczkowania wolumetrycznego Karla Fishera (V-KFT) PN-EN 16682:2017-05","categories":["materials","water","construction"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Building Materials: - samples (drill cuttings) taken Water content Karl Fisher volumetric titration method (V-KFT) Range Water content Scope Volumetric Karl Fisher titration PN-EN 16682:2017-05","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(1,00 - 10,00) %"},{"name":"含水量 / Water content"},{"name":"范围","range":"(1,00 – 10,00) %"},{"name":"Volumetric Karl Fisher titration"}],"search_zh":"水分含量 范围 含水量 / Water content 范围 PN-EN 16682:2017-05"},{"_id":"6a5dc9abf1c10c8ce825a47f","lab_id":"69ad52a3de79e566650fba59","country":"PL","accr_number":"AB 1904","accr_body":"PCA","test_object":"Materiały budowlane - próbki (fragmenty) pobrane z obiektów budowlanych, Building Materials:","test_object_en":"Building materials - samples (fragments) taken from building structures","methodology":"Wilgotność sorpcyjna","methodology_en":"Sorption moisture content","parameters":[{"name":"Zakres","range":"(0,01 - 20,00) %"},{"name":"Sorption moisture"},{"name":"Scope","range":"(0,01 – 20,00) %"}],"parameters_en":[{"name":"Range","range":"(0,01 - 20,00) %"},{"name":"Sorption moisture"},{"name":"Scope","range":"(0,01 – 20,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Wilgotność sorpcyjna\nZakres:\nZakres (0,01 - 20,00) %\nSorption moisture\nScope (0,01 – 20,00) %\nMetoda wagowa","reference":"ŐNORM B 3355:2017","norm_bases":["ŐNORM B 3355:2017"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały budowlane - próbki (fragmenty) pobrane z obiektów budowlanych, Building Materials: Wilgotność sorpcyjna\nZakres:\nZakres (0,01 - 20,00) %\nSorption moisture\nScope (0,01 – 20,00) %\nMetoda wagowa ŐNORM B 3355:2017 Materialy budowlane - probki (fragmenty) pobrane z obiektow budowlanych, Building Materials: Wilgotnosc sorpcyjna\nZakres:\nZakres (0,01 - 20,00) %\nSorption moisture\nScope (0,01 – 20,00) %\nMetoda wagowa ONORM B 3355:2017","categories":["materials","construction"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Building materials - samples (fragments) taken from building structures Sorption moisture content Gravimetric method Range Sorption moisture Scope ŐNORM B 3355:2017","parameters_zh":[{"name":"范围","range":"(0,01 - 20,00) %"},{"name":"Sorption moisture"},{"name":"范围","range":"(0,01 – 20,00) %"}],"search_zh":"重量法 范围 范围 ŐNORM B 3355:2017","technique_zh":"重量法"},{"_id":"6a5dc9abf1c10c8ce825a480","lab_id":"69ad52a3de79e566650fba59","country":"PL","accr_number":"AB 1904","accr_body":"PCA","test_object":"Materiały budowlane - próbki (zwierciny, fragmenty) pobrane z obiektów budowlanych, Building Materials: - samples (drill cuttings,","test_object_en":"Building materials - samples (drill cuttings, fragments) taken from building structures","methodology":"Wilgotność masowa","methodology_en":"Mass moisture content","parameters":[{"name":"Zakres","range":"(0,01 - 50,00) %"},{"name":"Mass moisture"},{"name":"Scope","range":"(0,01 – 50,00) %"}],"parameters_en":[{"name":"Range","range":"(0,01 - 50,00) %"},{"name":"Mass moisture"},{"name":"Scope","range":"(0,01 – 50,00) %"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Wilgotność masowa\nZakres:\nZakres (0,01 - 50,00) %\nMass moisture\nScope (0,01 – 50,00) %\nMetoda grawimetryczna","reference":"PN-EN ISO 12570:2002","norm_bases":["PN-EN ISO 12570:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały budowlane - próbki (zwierciny, fragmenty) pobrane z obiektów budowlanych, Building Materials: - samples (drill cuttings, Wilgotność masowa\nZakres:\nZakres (0,01 - 50,00) %\nMass moisture\nScope (0,01 – 50,00) %\nMetoda grawimetryczna PN-EN ISO 12570:2002 Materialy budowlane - probki (zwierciny, fragmenty) pobrane z obiektow budowlanych, Building Materials: - samples (drill cuttings, Wilgotnosc masowa\nZakres:\nZakres (0,01 - 50,00) %\nMass moisture\nScope (0,01 – 50,00) %\nMetoda grawimetryczna PN-EN ISO 12570:2002","categories":["materials","construction"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Building materials - samples (drill cuttings, fragments) taken from building structures Mass moisture content Gravimetric method Range Mass moisture Scope PN-EN ISO 12570:2002","parameters_zh":[{"name":"范围","range":"(0,01 - 50,00) %"},{"name":"Mass moisture"},{"name":"范围","range":"(0,01 – 50,00) %"}],"search_zh":"重量法 范围 范围 PN-EN ISO 12570:2002","technique_zh":"重量法"}],"has_pdf":true}