{"lab":{"_id":"69ad52a3de79e566650fba41","accr_number":"AB 1892","country":"PL","accr_body":"PCA","address":"WOJCIECH MATCZAK, ul. Kasztanowa 19, 87-100 Toruń","categories":["construction"],"city":"Toruń","imported_at":"2026-03-08T10:42:43.265Z","methods_count":2,"name":"INŻYNIERIA BUDOWNICTWA – FORUM","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1892.pdf"],"scope_summary":"","search_text":"inżynieria budownictwa – forum wojciech matczak, ul. kasztanowa 19, 87-100 toruń construction other","status":"active","updated_at":"2026-03-08T14:51:01.256Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:01.256Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201892,podmiot.html","fields_of_testing":[{"codes":"J/5","pl":"Badania mechaniczne – wyroby i materiały budowlane","en":"Mechanical tests - building products and materials"},{"codes":"N/5","pl":"Badania właściwości fizycznych – wyroby i materiały budowlane","en":"Tests of physical properties - building products and materials"}],"issue":{"no":"1","date":"19.01.2024"},"parse_date":"2026-07-20T07:09:31.265Z","parse_source":"script-pdfplumber","map_coord":[53.029109,18.647729],"map_geo":"nominatim-street","has_en":true,"category_counts":{"construction":2},"category_scores":{"construction":2},"has_zh":true},"methods":[{"_id":"6a5dc9abf1c10c8ce825a3d2","lab_id":"69ad52a3de79e566650fba41","country":"PL","accr_number":"AB 1892","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres siły","range":"(100 - 2000) kN"}],"parameters_en":[{"name":"Force range","range":"(100 - 2000) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres siły (100 - 2000) kN","reference":"PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12390-3:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Wytrzymałość na ściskanie\nZakres siły (100 - 2000) kN PN-EN 12390-3:2019-07 Beton Wytrzymalosc na sciskanie\nZakres sily (100 - 2000) kN PN-EN 12390-3:2019-07","categories":["construction"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete Compressive strength Force range PN-EN 12390-3:2019-07","methodology_zh":"抗压强度","parameters_zh":[{"name":"力值范围","range":"(100 - 2000) kN"}],"search_zh":"混凝土 抗压强度 力值范围 PN-EN 12390-3:2019-07","test_object_zh":"混凝土"},{"_id":"6a5dc9abf1c10c8ce825a3d3","lab_id":"69ad52a3de79e566650fba41","country":"PL","accr_number":"AB 1892","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Gęstość","methodology_en":"Density","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość","reference":"PN-EN 12390-7:2019-08 z wyłączeniem p. 6.5 | PN-EN 12390-7:2019-08/AC:2021-01","norm_bases":["PN-EN 12390-7:2019-08 z wyłączeniem p. 6.5","PN-EN 12390-7:2019-08/AC:2021-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Gęstość PN-EN 12390-7:2019-08 z wyłączeniem p. 6.5 | PN-EN 12390-7:2019-08/AC:2021-01 Beton Gestosc PN-EN 12390-7:2019-08 z wylaczeniem p. 6.5 | PN-EN 12390-7:2019-08/AC:2021-01","categories":["construction"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete Density PN-EN 12390-7:2019-08 z wyłączeniem p. 6.5 | PN-EN 12390-7:2019-08/AC:2021-01","methodology_zh":"密度","search_zh":"混凝土 密度 PN-EN 12390-7:2019-08 z wyłączeniem p. 6.5 | PN-EN 12390-7:2019-08/AC:2021-01","test_object_zh":"混凝土"}],"has_pdf":true}