{"lab":{"_id":"69ad52a3de79e566650fba13","accr_number":"AB 1868","country":"PL","accr_body":"PCA","address":"ul. Duńska 9, 54-427 Wrocław","categories":["water","microbiology","food","pharma"],"city":"Wrocław","imported_at":"2026-03-08T10:42:43.265Z","methods_count":61,"name":"EKOLABOS Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1868.pdf"],"scope_summary":"","search_text":"ekolabos sp. z o.o. ul. duńska 9, 54-427 wrocław pharma electronics other water microbiology automotive food","status":"active","updated_at":"2026-03-08T14:50:59.913Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T15:20:38.557Z","location":{"type":"Point","coordinates":[17.0385,51.1079]},"email_confidence":"high","email_mx":true,"email_source":"https://ekolabos.pl/en/contact/","fields_of_testing":[{"codes":"C/28; C/29","pl":"Badania chemiczne wody, wody do spożycia przez ludzi","en":"Chemical tests of water, drinking water"},{"codes":"N/28; N/29","pl":"Badania właściwości fizycznych wody, wody do spożycia przez ludzi","en":"Tests of physical properties of water, drinking water"},{"codes":"K/4; K/22; K/28; K/29; K/42","pl":"Badania mikrobiologiczne wyrobów chemicznych, żywności, wody, wody do spożycia przez ludzi, kosmetyków,","en":"Microbiological tests of chemical products, food, water, drinking water, cosmetics"},{"codes":"P/28; P/29","pl":"Pobieranie próbek wody, wody do spożycia przez ludzi","en":"Sampling of water, drinking water"}],"issue":{"no":"6","date":"04.05.2026"},"parse_date":"2026-08-17T15:20:38.557Z","parse_source":"agent-claude-code","map_coord":[51.110257,16.973625],"map_geo":"nominatim-street","lab_locations":[{"name":"Pracownia Fizykochemii","address":"ul. Duńska 9","city":"Wrocław","postal":"54-427"},{"name":"Pracownia Mikrobiologii","address":"ul. Duńska 9","city":"Wrocław","postal":"54-427"},{"name":"Dział Obsługi Klienta","address":"ul. Muchoborska 16","city":"Wrocław","postal":"54-424"}],"scope_format":"PCA::pracownie+elastyczny+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/f1a80fafcda9a545941ed2d05e30afb4/AB%201868.pdf","has_en":true,"category_counts":{"water":39,"microbiology":20,"food":16,"pharma":6,"other":2},"category_scores":{"water":18.33,"microbiology":4.82,"food":3.08,"pharma":0.43,"other":0.05},"has_zh":true,"lab_locations_zh":[{"name":"Pracownia Fizykochemii","address":"ul. Duńska 9","city":"Wrocław","postal":"54-427"},{"name":"微生物室","address":"ul. Duńska 9","city":"Wrocław","postal":"54-427"},{"name":"Dział Obsługi Klienta","address":"ul. Muchoborska 16","city":"Wrocław","postal":"54-424"}]},"methods":[{"_id":"6a8326c6884ede9a1b2c50b4","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(100 − 2500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 − 2500) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888","norm_bases":["PN-EN 27888"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Fizykochemii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Przewodność elektryczna właściwa\nZakres (100 − 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888 Woda E, Woda do spozycia przez ludzi E Przewodnosc elektryczna wlasciwa\nZakres (100 − 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(100 − 2500) μS/cm"}],"search_en":"Water E, Water intended for human consumption E Electrical conductivity Conductometric method Range PN-EN 27888","technique_en":"Conductometric method","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 − 2500) μS/cm"}],"search_zh":"水 E、生活饮用水 E 电导率 电导法 范围 PN-EN 27888","technique_zh":"电导法","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a8326c6884ede9a1b2c50b5","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 − 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 − 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523","norm_bases":["PN-EN ISO 10523"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Fizykochemii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E pH\nZakres 2,0 − 10,0\nMetoda potencjometryczna PN-EN ISO 10523 Woda E, Woda do spozycia przez ludzi E pH\nZakres 2,0 − 10,0\nMetoda potencjometryczna PN-EN ISO 10523","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 − 10,0"}],"search_en":"Water E, Water intended for human consumption E pH Potentiometric method Range PN-EN ISO 10523","technique_en":"Potentiometric method","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 − 10,0"}],"search_zh":"水 E、生活饮用水 E pH 值 电位法 范围 PN-EN ISO 10523","technique_zh":"电位法","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a8326c6884ede9a1b2c50b6","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 − 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 − 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1","norm_bases":["PN-EN ISO 7027-1"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Fizykochemii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Mętność\nZakres (0,20 − 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1 Woda E, Woda do spozycia przez ludzi E Metnosc\nZakres (0,20 − 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 − 100) NTU"}],"search_en":"Water E, Water intended for human consumption E Turbidity Nephelometric method Range PN-EN ISO 7027-1","technique_en":"Nephelometric method","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 − 100) NTU"}],"search_zh":"水 E、生活饮用水 E 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1","technique_zh":"浊度法（散射法）","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a8326c6884ede9a1b2c50b7","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,10 − 3,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,10 − 3,5) mg/l\nMetoda spektrofotometryczna","reference":"PB-01 na podstawie testu Merck 1.14752.0001","norm_bases":["PB-01 na podstawie testu Merck 1.14752.0001"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Fizykochemii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Stężenie jonu amonowego\nZakres (0,10 − 3,5) mg/l\nMetoda spektrofotometryczna PB-01 na podstawie testu Merck 1.14752.0001 Woda E, Woda do spozycia przez ludzi E Stezenie jonu amonowego\nZakres (0,10 − 3,5) mg/l\nMetoda spektrofotometryczna PB-01 na podstawie testu Merck 1.14752.0001","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,10 − 3,5) mg/l"}],"search_en":"Water E, Water intended for human consumption E Ammonium ion concentration Spectrophotometric method Range PB-01 na podstawie testu Merck 1.14752.0001","technique_en":"Spectrophotometric method","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,10 − 3,5) mg/l"}],"search_zh":"水 E、生活饮用水 E 铵离子浓度 分光光度法 范围 PB-01 na podstawie testu Merck 1.14752.0001","technique_zh":"分光光度法","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a8326c6884ede9a1b2c50b8","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(5,0 − 80) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (5,0 − 80) mg/l\nMetoda spektrofotometryczna","reference":"PB-02 na podstawie testu Merck 1.14773.0001","norm_bases":["PB-02 na podstawie testu Merck 1.14773.0001"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Fizykochemii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Stężenie azotanów\nZakres (5,0 − 80) mg/l\nMetoda spektrofotometryczna PB-02 na podstawie testu Merck 1.14773.0001 Woda E, Woda do spozycia przez ludzi E Stezenie azotanow\nZakres (5,0 − 80) mg/l\nMetoda spektrofotometryczna PB-02 na podstawie testu Merck 1.14773.0001","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(5,0 − 80) mg/l"}],"search_en":"Water E, Water intended for human consumption E Nitrate concentration Spectrophotometric method Range PB-02 na podstawie testu Merck 1.14773.0001","technique_en":"Spectrophotometric method","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(5,0 − 80) mg/l"}],"search_zh":"水 E、生活饮用水 E 硝酸盐浓度 分光光度法 范围 PB-02 na podstawie testu Merck 1.14773.0001","technique_zh":"分光光度法","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a8326c6884ede9a1b2c50b9","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,10 − 0,60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,10 − 0,60) mg/l\nMetoda spektrofotometryczna","reference":"PB-03 na podstawie testu Merck 1.14776.0001","norm_bases":["PB-03 na podstawie testu Merck 1.14776.0001"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Fizykochemii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Stężenie azotynów\nZakres (0,10 − 0,60) mg/l\nMetoda spektrofotometryczna PB-03 na podstawie testu Merck 1.14776.0001 Woda E, Woda do spozycia przez ludzi E Stezenie azotynow\nZakres (0,10 − 0,60) mg/l\nMetoda spektrofotometryczna PB-03 na podstawie testu Merck 1.14776.0001","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,10 − 0,60) mg/l"}],"search_en":"Water E, Water intended for human consumption E Nitrite concentration Spectrophotometric method Range PB-03 na podstawie testu Merck 1.14776.0001","technique_en":"Spectrophotometric method","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,10 − 0,60) mg/l"}],"search_zh":"水 E、生活饮用水 E 亚硝酸盐浓度 分光光度法 范围 PB-03 na podstawie testu Merck 1.14776.0001","technique_zh":"分光光度法","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a8326c6884ede9a1b2c50ba","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,010 − 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,010 − 20) mg/l\nMetoda spektrofotometryczna","reference":"PB-04 na podstawie testu Merck 1.01846.0001","norm_bases":["PB-04 na podstawie testu Merck 1.01846.0001"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Fizykochemii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Stężenie manganu\nZakres (0,010 − 20) mg/l\nMetoda spektrofotometryczna PB-04 na podstawie testu Merck 1.01846.0001 Woda E, Woda do spozycia przez ludzi E Stezenie manganu\nZakres (0,010 − 20) mg/l\nMetoda spektrofotometryczna PB-04 na podstawie testu Merck 1.01846.0001","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,010 − 20) mg/l"}],"search_en":"Water E, Water intended for human consumption E Manganese concentration Spectrophotometric method Range PB-04 na podstawie testu Merck 1.01846.0001","technique_en":"Spectrophotometric method","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,010 − 20) mg/l"}],"search_zh":"水 E、生活饮用水 E 锰浓度 分光光度法 范围 PB-04 na podstawie testu Merck 1.01846.0001","technique_zh":"分光光度法","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a8326c6884ede9a1b2c50bb","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,020 − 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,020 − 50) mg/l\nMetoda spektrofotometryczna","reference":"PB-05 na podstawie testu Merck 1.14761.0001","norm_bases":["PB-05 na podstawie testu Merck 1.14761.0001"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Fizykochemii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Stężenie żelaza\nZakres (0,020 − 50) mg/l\nMetoda spektrofotometryczna PB-05 na podstawie testu Merck 1.14761.0001 Woda E, Woda do spozycia przez ludzi E Stezenie zelaza\nZakres (0,020 − 50) mg/l\nMetoda spektrofotometryczna PB-05 na podstawie testu Merck 1.14761.0001","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,020 − 50) mg/l"}],"search_en":"Water E, Water intended for human consumption E Iron concentration Spectrophotometric method Range PB-05 na podstawie testu Merck 1.14761.0001","technique_en":"Spectrophotometric method","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,020 − 50) mg/l"}],"search_zh":"水 E、生活饮用水 E 铁浓度 分光光度法 范围 PB-05 na podstawie testu Merck 1.14761.0001","technique_zh":"分光光度法","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a8326c6884ede9a1b2c50bc","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(10 − 250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chlorków\nZakres (10 − 250) mg/l\nMetoda spektrofotometryczna","reference":"PB-06 na podstawie testu Merck 1.14897.0001","norm_bases":["PB-06 na podstawie testu Merck 1.14897.0001"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Fizykochemii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Stężenie chlorków\nZakres (10 − 250) mg/l\nMetoda spektrofotometryczna PB-06 na podstawie testu Merck 1.14897.0001 Woda E, Woda do spozycia przez ludzi E Stezenie chlorkow\nZakres (10 − 250) mg/l\nMetoda spektrofotometryczna PB-06 na podstawie testu Merck 1.14897.0001","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(10 − 250) mg/l"}],"search_en":"Water E, Water intended for human consumption E Chloride concentration Spectrophotometric method Range PB-06 na podstawie testu Merck 1.14897.0001","technique_en":"Spectrophotometric method","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(10 − 250) mg/l"}],"search_zh":"水 E、生活饮用水 E 氯化物浓度 分光光度法 范围 PB-06 na podstawie testu Merck 1.14897.0001","technique_zh":"分光光度法","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a8326c6884ede9a1b2c50bd","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 − 250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 − 250) mg/l\nMetoda spektrofotometryczna","reference":"PB-07 na podstawie testu Merck 1.02537.0001","norm_bases":["PB-07 na podstawie testu Merck 1.02537.0001"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Fizykochemii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Stężenie siarczanów\nZakres (10 − 250) mg/l\nMetoda spektrofotometryczna PB-07 na podstawie testu Merck 1.02537.0001 Woda E, Woda do spozycia przez ludzi E Stezenie siarczanow\nZakres (10 − 250) mg/l\nMetoda spektrofotometryczna PB-07 na podstawie testu Merck 1.02537.0001","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 − 250) mg/l"}],"search_en":"Water E, Water intended for human consumption E Sulfate concentration Spectrophotometric method Range PB-07 na podstawie testu Merck 1.02537.0001","technique_en":"Spectrophotometric method","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 − 250) mg/l"}],"search_zh":"水 E、生活饮用水 E 硫酸盐浓度 分光光度法 范围 PB-07 na podstawie testu Merck 1.02537.0001","technique_zh":"分光光度法","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a8326c6884ede9a1b2c50be","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Stężenie sumaryczne wapnia i magnezu","parameters":[{"name":"Zakres","range":"(10 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie sumaryczne wapnia i magnezu\nZakres (10 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059","norm_bases":["PN-ISO 6059"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Fizykochemii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Stężenie sumaryczne wapnia i magnezu\nZakres (10 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059 Woda E, Woda do spozycia przez ludzi E Stezenie sumaryczne wapnia i magnezu\nZakres (10 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total concentration of calcium and magnesium","parameters_en":[{"name":"Range","range":"(10 – 500) mg/l CaCO3"}],"search_en":"Water E, Water intended for human consumption E Total concentration of calcium and magnesium Titrimetric method Range PN-ISO 6059","technique_en":"Titrimetric method","test_object_en":"Water E, Water intended for human consumption E","parameters_zh":[{"name":"范围","range":"(10 – 500) mg/l CaCO3"}],"search_zh":"水 E、生活饮用水 E 滴定法 范围 PN-ISO 6059","technique_zh":"滴定法","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a8326c6884ede9a1b2c50bf","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(2,0 − 320) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres (2,0 − 320) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058","norm_bases":["PN-ISO 6058"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Fizykochemii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Stężenie wapnia\nZakres (2,0 − 320) mg/l\nMetoda miareczkowa PN-ISO 6058 Woda E, Woda do spozycia przez ludzi E Stezenie wapnia\nZakres (2,0 − 320) mg/l\nMetoda miareczkowa PN-ISO 6058","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(2,0 − 320) mg/l"}],"search_en":"Water E, Water intended for human consumption E Calcium concentration Titrimetric method Range PN-ISO 6058","technique_en":"Titrimetric method","test_object_en":"Water E, Water intended for human consumption E","parameters_zh":[{"name":"范围","range":"(2,0 − 320) mg/l"}],"search_zh":"水 E、生活饮用水 E 钙浓度 滴定法 范围 PN-ISO 6058","technique_zh":"滴定法","methodology_zh":"钙浓度","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a8326c6884ede9a1b2c50c0","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Stężenie magnezu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C-04554-4 Zał.A","norm_bases":["PN-C-04554-4 Zał.A"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Fizykochemii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Stężenie magnezu (z obliczeń) PN-C-04554-4 Zał.A Woda E, Woda do spozycia przez ludzi E Stezenie magnezu (z obliczen) PN-C-04554-4 Zal.A","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnesium concentration (calculated)","search_en":"Water E, Water intended for human consumption E Magnesium concentration (calculated) PN-C-04554-4 Zał.A","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"镁浓度（计算值）","search_zh":"水 E、生活饮用水 E 镁浓度（计算值） PN-C-04554-4 Zał.A","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a8326c6884ede9a1b2c50c1","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50-10) mg/lO2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50-10) mg/lO2\nMetoda miareczkowa","reference":"PN-EN ISO 8467","norm_bases":["PN-EN ISO 8467"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Fizykochemii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Indeks nadmanganianowy\nZakres (0,50-10) mg/lO2\nMetoda miareczkowa PN-EN ISO 8467 Woda E, Woda do spozycia przez ludzi E Indeks nadmanganianowy\nZakres (0,50-10) mg/lO2\nMetoda miareczkowa PN-EN ISO 8467","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50-10) mg/lO2"}],"search_en":"Water E, Water intended for human consumption E Permanganate index Titrimetric method Range PN-EN ISO 8467","technique_en":"Titrimetric method","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50-10) mg/lO2"}],"search_zh":"水 E、生活饮用水 E 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467","technique_zh":"滴定法","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a8326c6884ede9a1b2c50c2","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Ogólna liczba mikroorganizmów w temperaturze 22°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 22°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222","norm_bases":["PN-EN ISO 6222"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Ogólna liczba mikroorganizmów w temperaturze 22°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222 Woda E, Woda do spozycia przez ludzi E Ogolna liczba mikroorganizmow w temperaturze 22°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total microorganism count at a temperature of 22°C","search_en":"Water E, Water intended for human consumption E Total microorganism count at a temperature of 22°C Plate method (pour plate) PN-EN ISO 6222","technique_en":"Plate method (pour plate)","test_object_en":"Water E, Water intended for human consumption E","search_zh":"水 E、生活饮用水 E 22°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222","technique_zh":"平板法（倾注培养）","test_object_zh":"水 E、生活饮用水 E","methodology_zh":"22°C 微生物总数"},{"_id":"6a8326c6884ede9a1b2c50c3","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Ogólna liczba mikroorganizmów w temperaturze 36°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222","norm_bases":["PN-EN ISO 6222"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Ogólna liczba mikroorganizmów w temperaturze 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222 Woda E, Woda do spozycia przez ludzi E Ogolna liczba mikroorganizmow w temperaturze 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total microorganism count at 36°C","search_en":"Water E, Water intended for human consumption E Total microorganism count at 36°C Plate method (pour plate) PN-EN ISO 6222","technique_en":"Plate method (pour plate)","test_object_en":"Water E, Water intended for human consumption E","search_zh":"水 E、生活饮用水 E 36°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222","technique_zh":"平板法（倾注培养）","test_object_zh":"水 E、生活饮用水 E","methodology_zh":"36°C 微生物总数"},{"_id":"6a8326c6884ede9a1b2c50c4","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2","norm_bases":["PN-EN ISO 7899-2"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2 Woda E, Woda do spozycia przez ludzi E Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water E, Water intended for human consumption E Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2","technique_en":"Membrane filtration method","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"粪肠球菌计数","search_zh":"水 E、生活饮用水 E 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2","technique_zh":"膜过滤法","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a8326c6884ede9a1b2c50c5","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1","norm_bases":["PN-EN ISO 9308-1"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1 Woda E, Woda do spozycia przez ludzi E Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1","categories":["water","microbiology"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water E, Water intended for human consumption E Escherichia coli count Membrane filtration method PN-EN ISO 9308-1","technique_en":"Membrane filtration method","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水 E、生活饮用水 E 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1","technique_zh":"膜过滤法","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a8326c6884ede9a1b2c50c6","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1","norm_bases":["PN-EN ISO 9308-1"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1 Woda E, Woda do spozycia przez ludzi E Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1","categories":["water","microbiology"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water E, Water intended for human consumption E Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1","technique_en":"Membrane filtration method","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"大肠菌群计数","search_zh":"水 E、生活饮用水 E 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1","technique_zh":"膜过滤法","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a8326c6884ede9a1b2c50c7","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Liczba Clostridium perfringens (łącznie ze sporami)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189","norm_bases":["PN-EN ISO 14189"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189 Woda E, Woda do spozycia przez ludzi E Liczba Clostridium perfringens (lacznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Clostridium perfringens count (including spores)","search_en":"Water E, Water intended for human consumption E Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189","technique_en":"Membrane filtration method","test_object_en":"Water E, Water intended for human consumption E","search_zh":"水 E、生活饮用水 E 产气荚膜梭菌计数（含芽孢） 膜过滤法 PN-EN ISO 14189","technique_zh":"膜过滤法","methodology_zh":"产气荚膜梭菌计数（含芽孢）","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a8326c6884ede9a1b2c50c8","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266","norm_bases":["PN-EN ISO 16266"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266 Woda E, Woda do spozycia przez ludzi E Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water E, Water intended for human consumption E Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266","technique_en":"Membrane filtration method","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"铜绿假单胞菌计数","search_zh":"水 E、生活饮用水 E 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266","technique_zh":"膜过滤法","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a8326c6884ede9a1b2c50c9","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Liczba bakterii Legionella sp., Matryca A: Procedura 5 (pożywka BCYE), Procedura 7 (pożywka GVPC), Matryca B: Procedura 6 (pożywka GVPC)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Legionella sp., Matryca A: Procedura 5 (pożywka BCYE), Procedura 7 (pożywka GVPC), Matryca B: Procedura 6 (pożywka GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731","norm_bases":["PN-EN ISO 11731"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Liczba bakterii Legionella sp., Matryca A: Procedura 5 (pożywka BCYE), Procedura 7 (pożywka GVPC), Matryca B: Procedura 6 (pożywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731 Woda E, Woda do spozycia przez ludzi E Liczba bakterii Legionella sp., Matryca A: Procedura 5 (pozywka BCYE), Procedura 7 (pozywka GVPC), Matryca B: Procedura 6 (pozywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731","categories":["microbiology","water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Legionella sp. count, Matrix A: Procedure 5 (BCYE medium), Procedure 7 (GVPC medium), Matrix B: Procedure 6 (GVPC medium)","search_en":"Water E, Water intended for human consumption E Legionella sp. count, Matrix A: Procedure 5 (BCYE medium), Procedure 7 (GVPC medium), Matrix B: Procedure 6 (GVPC medium) Membrane filtration method PN-EN ISO 11731","technique_en":"Membrane filtration method","test_object_en":"Water E, Water intended for human consumption E","search_zh":"水 E、生活饮用水 E 膜过滤法 PN-EN ISO 11731","technique_zh":"膜过滤法","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a8326c6884ede9a1b2c50ca","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Liczba Staphylococcus aureus","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Staphylococcus aureus\nMetoda filtracji membranowej","reference":"PN-Z-11001-3 Zał. A","norm_bases":["PN-Z-11001-3 Zał. A"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Liczba Staphylococcus aureus\nMetoda filtracji membranowej PN-Z-11001-3 Zał. A Woda E, Woda do spozycia przez ludzi E Liczba Staphylococcus aureus\nMetoda filtracji membranowej PN-Z-11001-3 Zal. A","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Staphylococcus aureus count","search_en":"Water E, Water intended for human consumption E Staphylococcus aureus count Membrane filtration method PN-Z-11001-3 Zał. A","technique_en":"Membrane filtration method","test_object_en":"Water E, Water intended for human consumption E","search_zh":"水 E、生活饮用水 E 金黄色葡萄球菌数 膜过滤法 PN-Z-11001-3 Zał. A","technique_zh":"膜过滤法","test_object_zh":"水 E、生活饮用水 E","methodology_zh":"金黄色葡萄球菌数"},{"_id":"6a8326c6884ede9a1b2c50cb","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda na pływalniach E","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266","norm_bases":["PN-EN ISO 16266"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda na pływalniach E Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266 Woda na plywalniach E Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Swimming pool water E Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water E","methodology_zh":"铜绿假单胞菌计数","search_zh":"游泳池水 E 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266","technique_zh":"膜过滤法","test_object_zh":"游泳池水 E"},{"_id":"6a8326c6884ede9a1b2c50cc","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda na pływalniach E","methodology":"Ogólna liczba mikroorganizmów w temperaturze 36°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222","norm_bases":["PN-EN ISO 6222"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda na pływalniach E Ogólna liczba mikroorganizmów w temperaturze 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222 Woda na plywalniach E Ogolna liczba mikroorganizmow w temperaturze 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total microorganism count at 36°C","search_en":"Swimming pool water E Total microorganism count at 36°C Plate method (pour plate) PN-EN ISO 6222","technique_en":"Plate method (pour plate)","test_object_en":"Swimming pool water E","search_zh":"游泳池水 E 36°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222","technique_zh":"平板法（倾注培养）","test_object_zh":"游泳池水 E","methodology_zh":"36°C 微生物总数"},{"_id":"6a8326c6884ede9a1b2c50cd","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda na pływalniach E","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1","norm_bases":["PN-EN ISO 9308-1"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda na pływalniach E Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1 Woda na plywalniach E Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1","categories":["water","microbiology"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Swimming pool water E Escherichia coli count Membrane filtration method PN-EN ISO 9308-1","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water E","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"游泳池水 E 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1","technique_zh":"膜过滤法","test_object_zh":"游泳池水 E"},{"_id":"6a8326c6884ede9a1b2c50ce","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda na pływalniach E","methodology":"Liczba bakterii Legionella sp., Matryca A: Procedura 5 (pożywka BCYE), Procedura 7(pożywka GVPC)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Legionella sp., Matryca A: Procedura 5 (pożywka BCYE), Procedura 7(pożywka GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731","norm_bases":["PN-EN ISO 11731"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda na pływalniach E Liczba bakterii Legionella sp., Matryca A: Procedura 5 (pożywka BCYE), Procedura 7(pożywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731 Woda na plywalniach E Liczba bakterii Legionella sp., Matryca A: Procedura 5 (pozywka BCYE), Procedura 7(pozywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731","categories":["microbiology","water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Legionella sp. count, Matrix A: Procedure 5 (BCYE medium), Procedure 7 (GVPC medium)","search_en":"Swimming pool water E Legionella sp. count, Matrix A: Procedure 5 (BCYE medium), Procedure 7 (GVPC medium) Membrane filtration method PN-EN ISO 11731","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water E","search_zh":"游泳池水 E 膜过滤法 PN-EN ISO 11731","technique_zh":"膜过滤法","test_object_zh":"游泳池水 E"},{"_id":"6a8326c6884ede9a1b2c50cf","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda na pływalniach E","methodology":"Liczba Staphylococcus aureus","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Staphylococcus aureus\nMetoda filtracji membranowej","reference":"PN-Z-11001-3 Zał. A","norm_bases":["PN-Z-11001-3 Zał. A"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda na pływalniach E Liczba Staphylococcus aureus\nMetoda filtracji membranowej PN-Z-11001-3 Zał. A Woda na plywalniach E Liczba Staphylococcus aureus\nMetoda filtracji membranowej PN-Z-11001-3 Zal. A","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Staphylococcus aureus count","search_en":"Swimming pool water E Staphylococcus aureus count Membrane filtration method PN-Z-11001-3 Zał. A","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water E","search_zh":"游泳池水 E 金黄色葡萄球菌数 膜过滤法 PN-Z-11001-3 Zał. A","technique_zh":"膜过滤法","test_object_zh":"游泳池水 E","methodology_zh":"金黄色葡萄球菌数"},{"_id":"6a8326c6884ede9a1b2c50d0","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność Salmonella spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1","norm_bases":["PN-EN ISO 6579-1"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1 Zywnosc E Obecnosc Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1","categories":["microbiology","food"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp.","search_en":"Food E Presence of Salmonella spp. Culture method with biochemical and serological confirmation PN-EN ISO 6579-1","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Food E","methodology_zh":"沙门氏菌属（Salmonella spp.）的检出","search_zh":"食品 E 沙门氏菌属（Salmonella spp.）的检出 培养法结合生化与血清学确认 PN-EN ISO 6579-1","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"食品 E"},{"_id":"6a8326c6884ede9a1b2c50d1","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność Listeria monocytogenes","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 11290-1","norm_bases":["PN-EN ISO 11290-1"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1 Zywnosc E Obecnosc Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1","categories":["food","microbiology"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Listeria monocytogenes","search_en":"Food E Presence of Listeria monocytogenes Culture method with biochemical confirmation PN-EN ISO 11290-1","technique_en":"Culture method with biochemical confirmation","test_object_en":"Food E","search_zh":"食品 E 单核细胞增生李斯特氏菌的检出 培养法结合生化确认 PN-EN ISO 11290-1","technique_zh":"培养法结合生化确认","test_object_zh":"食品 E","methodology_zh":"单核细胞增生李斯特氏菌的检出"},{"_id":"6a8326c6884ede9a1b2c50d2","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba bakterii grupy coli w 37°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii grupy coli w 37°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 4832","norm_bases":["PN-ISO 4832"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba bakterii grupy coli w 37°C\nMetoda płytkowa (posiew wgłębny) PN-ISO 4832 Zywnosc E Liczba bakterii grupy coli w 37°C\nMetoda plytkowa (posiew wglebny) PN-ISO 4832","categories":["food","microbiology"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count at 37°C","search_en":"Food E Coliform bacteria count at 37°C Plate method (pour plate) PN-ISO 4832","technique_en":"Plate method (pour plate)","test_object_en":"Food E","search_zh":"食品 E 平板法（倾注培养） PN-ISO 4832","technique_zh":"平板法（倾注培养）","test_object_zh":"食品 E"},{"_id":"6a8326c6884ede9a1b2c50d3","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba Enterobacteriaceae w 37°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba Enterobacteriaceae w 37°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 21528-2","norm_bases":["PN-EN ISO 21528-2"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba Enterobacteriaceae w 37°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 21528-2 Zywnosc E Liczba Enterobacteriaceae w 37°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 21528-2","categories":["food"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Enterobacteriaceae count at 37°C","search_en":"Food E Enterobacteriaceae count at 37°C Plate method (pour plate) PN-EN ISO 21528-2","technique_en":"Plate method (pour plate)","test_object_en":"Food E","search_zh":"食品 E 37°C 肠杆菌科计数 平板法（倾注培养） PN-EN ISO 21528-2","technique_zh":"平板法（倾注培养）","test_object_zh":"食品 E","methodology_zh":"37°C 肠杆菌科计数"},{"_id":"6a8326c6884ede9a1b2c50d4","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba β-glukuronidazo-dodatnich Escherichia coli","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba β-glukuronidazo-dodatnich Escherichia coli\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 16649-2","norm_bases":["PN-ISO 16649-2"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba β-glukuronidazo-dodatnich Escherichia coli\nMetoda płytkowa (posiew wgłębny) PN-ISO 16649-2 Zywnosc E Liczba β-glukuronidazo-dodatnich Escherichia coli\nMetoda plytkowa (posiew wglebny) PN-ISO 16649-2","categories":["food","microbiology"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of β-glucuronidase-positive Escherichia coli","search_en":"Food E Count of β-glucuronidase-positive Escherichia coli Plate method (pour plate) PN-ISO 16649-2","technique_en":"Plate method (pour plate)","test_object_en":"Food E","search_zh":"食品 E 平板法（倾注培养） PN-ISO 16649-2","technique_zh":"平板法（倾注培养）","test_object_zh":"食品 E"},{"_id":"6a8326c6884ede9a1b2c50d5","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Żywność E","methodology":"Ogólna liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 4833-1","norm_bases":["PN-EN ISO 4833-1"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Ogólna liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 4833-1 Zywnosc E Ogolna liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) PN-EN ISO 4833-1","categories":["food","microbiology"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count","search_en":"Food E Total viable count Plate method (pour plate) PN-EN ISO 4833-1","technique_en":"Plate method (pour plate)","test_object_en":"Food E","methodology_zh":"微生物总数","search_zh":"食品 E 微生物总数 平板法（倾注培养） PN-EN ISO 4833-1","technique_zh":"平板法（倾注培养）","test_object_zh":"食品 E"},{"_id":"6a8326c6884ede9a1b2c50d6","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba Listeria monocytogenes","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba Listeria monocytogenes\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 11290-2","norm_bases":["PN-EN ISO 11290-2"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba Listeria monocytogenes\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 11290-2 Zywnosc E Liczba Listeria monocytogenes\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 11290-2","categories":["food","microbiology"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Listeria monocytogenes count","search_en":"Food E Listeria monocytogenes count Plate method (spread plate) PN-EN ISO 11290-2","technique_en":"Plate method (spread plate)","test_object_en":"Food E","search_zh":"食品 E 单核细胞增生李斯特氏菌计数 平板法（表面涂布） PN-EN ISO 11290-2","technique_zh":"平板法（表面涂布）","test_object_zh":"食品 E","methodology_zh":"单核细胞增生李斯特氏菌计数"},{"_id":"6a8326c6884ede9a1b2c50d7","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba gronkowców koagulazododatnich (Staphylococcus aureus i innych gatunków)","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba gronkowców koagulazododatnich (Staphylococcus aureus i innych gatunków)\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 6888-1","norm_bases":["PN-EN ISO 6888-1"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba gronkowców koagulazododatnich (Staphylococcus aureus i innych gatunków)\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 6888-1 Zywnosc E Liczba gronkowcow koagulazododatnich (Staphylococcus aureus i innych gatunkow)\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 6888-1","categories":["food"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coagulase-positive staphylococci count (Staphylococcus aureus and other species)","search_en":"Food E Coagulase-positive staphylococci count (Staphylococcus aureus and other species) Plate method (spread plate) PN-EN ISO 6888-1","technique_en":"Plate method (spread plate)","test_object_en":"Food E","search_zh":"食品 E 凝固酶阳性葡萄球菌计数（金黄色葡萄球菌及其他菌种） 平板法（表面涂布） PN-EN ISO 6888-1","technique_zh":"平板法（表面涂布）","test_object_zh":"食品 E","methodology_zh":"凝固酶阳性葡萄球菌计数（金黄色葡萄球菌及其他菌种）"},{"_id":"6a8326c6884ede9a1b2c50d8","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Żywność o aktywności wody wyższej niż 0,95 E","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-ISO 21527-1","norm_bases":["PN-ISO 21527-1"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność o aktywności wody wyższej niż 0,95 E Liczba drożdży i pleśni\nMetoda płytkowa (posiew powierzchniowy) PN-ISO 21527-1 Zywnosc o aktywnosci wody wyzszej niz 0,95 E Liczba drozdzy i plesni\nMetoda plytkowa (posiew powierzchniowy) PN-ISO 21527-1","categories":["water","food"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Food with water activity higher than 0,95 E Yeast and mould count Plate method (spread plate) PN-ISO 21527-1","technique_en":"Plate method (spread plate)","test_object_en":"Food with water activity higher than 0,95 E","methodology_zh":"酵母菌与霉菌计数","search_zh":"酵母菌与霉菌计数 平板法（表面涂布） PN-ISO 21527-1","technique_zh":"平板法（表面涂布）"},{"_id":"6a8326c6884ede9a1b2c50d9","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Żywność o aktywności wody niższej lub równiej 0,95 E","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-ISO 21527-2","norm_bases":["PN-ISO 21527-2"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność o aktywności wody niższej lub równiej 0,95 E Liczba drożdży i pleśni\nMetoda płytkowa (posiew powierzchniowy) PN-ISO 21527-2 Zywnosc o aktywnosci wody nizszej lub rowniej 0,95 E Liczba drozdzy i plesni\nMetoda plytkowa (posiew powierzchniowy) PN-ISO 21527-2","categories":["water","food"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Food with a water activity lower than or equal to 0,95 E Yeast and mould count Plate method (spread plate) PN-ISO 21527-2","technique_en":"Plate method (spread plate)","test_object_en":"Food with a water activity lower than or equal to 0,95 E","methodology_zh":"酵母菌与霉菌计数","search_zh":"酵母菌与霉菌计数 平板法（表面涂布） PN-ISO 21527-2","technique_zh":"平板法（表面涂布）"},{"_id":"6a8326c6884ede9a1b2c50da","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Mleko i produkty mleczne E","methodology":"Liczba bakterii grupy coli w 30°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii grupy coli w 30°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 4832","norm_bases":["PN-ISO 4832"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Mleko i produkty mleczne E Liczba bakterii grupy coli w 30°C\nMetoda płytkowa (posiew wgłębny) PN-ISO 4832 Mleko i produkty mleczne E Liczba bakterii grupy coli w 30°C\nMetoda plytkowa (posiew wglebny) PN-ISO 4832","categories":["food","microbiology"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count at 30°C","search_en":"Milk and dairy products E Coliform bacteria count at 30°C Plate method (pour plate) PN-ISO 4832","technique_en":"Plate method (pour plate)","test_object_en":"Milk and dairy products E","search_zh":"乳与乳制品 E 平板法（倾注培养） PN-ISO 4832","technique_zh":"平板法（倾注培养）","test_object_zh":"乳与乳制品 E"},{"_id":"6a8326c6884ede9a1b2c50db","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Mleko i produkty mleczne E","methodology":"Obecność Salmonella spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1","norm_bases":["PN-EN ISO 6579-1"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Mleko i produkty mleczne E Obecność Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1 Mleko i produkty mleczne E Obecnosc Salmonella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1","categories":["microbiology","food"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella spp.","search_en":"Milk and dairy products E Presence of Salmonella spp. Culture method with biochemical and serological confirmation PN-EN ISO 6579-1","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Milk and dairy products E","methodology_zh":"沙门氏菌属（Salmonella spp.）的检出","search_zh":"乳与乳制品 E 沙门氏菌属（Salmonella spp.）的检出 培养法结合生化与血清学确认 PN-EN ISO 6579-1","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"乳与乳制品 E"},{"_id":"6a8326c6884ede9a1b2c50dc","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Mleko i produkty mleczne E","methodology":"Liczba Enterobacteriaceae w 37°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba Enterobacteriaceae w 37°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 21528-2","norm_bases":["PN-EN ISO 21528-2"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Mleko i produkty mleczne E Liczba Enterobacteriaceae w 37°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 21528-2 Mleko i produkty mleczne E Liczba Enterobacteriaceae w 37°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 21528-2","categories":["food"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Enterobacteriaceae count at 37°C","search_en":"Milk and dairy products E Enterobacteriaceae count at 37°C Plate method (pour plate) PN-EN ISO 21528-2","technique_en":"Plate method (pour plate)","test_object_en":"Milk and dairy products E","search_zh":"乳与乳制品 E 37°C 肠杆菌科计数 平板法（倾注培养） PN-EN ISO 21528-2","technique_zh":"平板法（倾注培养）","test_object_zh":"乳与乳制品 E","methodology_zh":"37°C 肠杆菌科计数"},{"_id":"6a8326c6884ede9a1b2c50dd","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Mleko i produkty mleczne E","methodology":"Obecność Listeria monocytogenes","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 11290-1","norm_bases":["PN-EN ISO 11290-1"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Mleko i produkty mleczne E Obecność Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1 Mleko i produkty mleczne E Obecnosc Listeria monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1","categories":["food","microbiology"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Listeria monocytogenes","search_en":"Milk and dairy products E Presence of Listeria monocytogenes Culture method with biochemical confirmation PN-EN ISO 11290-1","technique_en":"Culture method with biochemical confirmation","test_object_en":"Milk and dairy products E","search_zh":"乳与乳制品 E 单核细胞增生李斯特氏菌的检出 培养法结合生化确认 PN-EN ISO 11290-1","technique_zh":"培养法结合生化确认","methodology_zh":"单核细胞增生李斯特氏菌的检出","test_object_zh":"乳与乳制品 E"},{"_id":"6a8326c6884ede9a1b2c50de","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Mleko i produkty mleczne E","methodology":"Liczba β-glukuronidazo-dodatnich Escherichia coli","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba β-glukuronidazo-dodatnich Escherichia coli\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 16649-2","norm_bases":["PN-ISO 16649-2"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Mleko i produkty mleczne E Liczba β-glukuronidazo-dodatnich Escherichia coli\nMetoda płytkowa (posiew wgłębny) PN-ISO 16649-2 Mleko i produkty mleczne E Liczba β-glukuronidazo-dodatnich Escherichia coli\nMetoda plytkowa (posiew wglebny) PN-ISO 16649-2","categories":["food","microbiology"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of β-glucuronidase-positive Escherichia coli","search_en":"Milk and dairy products E Count of β-glucuronidase-positive Escherichia coli Plate method (pour plate) PN-ISO 16649-2","technique_en":"Plate method (pour plate)","test_object_en":"Milk and dairy products E","search_zh":"乳与乳制品 E 平板法（倾注培养） PN-ISO 16649-2","technique_zh":"平板法（倾注培养）","test_object_zh":"乳与乳制品 E"},{"_id":"6a8326c6884ede9a1b2c50df","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Mleko i produkty mleczne E","methodology":"Ogólna liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 4833-1","norm_bases":["PN-EN ISO 4833-1"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Mleko i produkty mleczne E Ogólna liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 4833-1 Mleko i produkty mleczne E Ogolna liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) PN-EN ISO 4833-1","categories":["food","microbiology"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count","search_en":"Milk and dairy products E Total viable count Plate method (pour plate) PN-EN ISO 4833-1","technique_en":"Plate method (pour plate)","test_object_en":"Milk and dairy products E","methodology_zh":"微生物总数","search_zh":"乳与乳制品 E 微生物总数 平板法（倾注培养） PN-EN ISO 4833-1","technique_zh":"平板法（倾注培养）","test_object_zh":"乳与乳制品 E"},{"_id":"6a8326c6884ede9a1b2c50e0","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Kosmetyki E","methodology":"Liczba mezofilnych bakterii tlenowych","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba mezofilnych bakterii tlenowych\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 21149","norm_bases":["PN-EN ISO 21149"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Kosmetyki E Liczba mezofilnych bakterii tlenowych\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 21149 Kosmetyki E Liczba mezofilnych bakterii tlenowych\nMetoda plytkowa (posiew wglebny) PN-EN ISO 21149","categories":["microbiology","pharma"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mesophilic aerobic bacteria count","search_en":"Cosmetics E Mesophilic aerobic bacteria count Plate method (pour plate) PN-EN ISO 21149","technique_en":"Plate method (pour plate)","test_object_en":"Cosmetics E","methodology_zh":"嗜温需氧菌计数","search_zh":"化妆品 E 嗜温需氧菌计数 平板法（倾注培养） PN-EN ISO 21149","technique_zh":"平板法（倾注培养）","test_object_zh":"化妆品 E"},{"_id":"6a8326c6884ede9a1b2c50e1","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Kosmetyki E","methodology":"Liczba drożdży i pleśni","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drożdży i pleśni\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 16212","norm_bases":["PN-EN ISO 16212"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Kosmetyki E Liczba drożdży i pleśni\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 16212 Kosmetyki E Liczba drozdzy i plesni\nMetoda plytkowa (posiew wglebny) PN-EN ISO 16212","categories":["pharma"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Yeast and mould count","search_en":"Cosmetics E Yeast and mould count Plate method (pour plate) PN-EN ISO 16212","technique_en":"Plate method (pour plate)","test_object_en":"Cosmetics E","methodology_zh":"酵母菌与霉菌计数","search_zh":"化妆品 E 酵母菌与霉菌计数 平板法（倾注培养） PN-EN ISO 16212","technique_zh":"平板法（倾注培养）","test_object_zh":"化妆品 E"},{"_id":"6a8326c6884ede9a1b2c50e2","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Kosmetyki E","methodology":"Obecność Candida albicans","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Candida albicans\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 18416","norm_bases":["PN-EN ISO 18416"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Kosmetyki E Obecność Candida albicans\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 18416 Kosmetyki E Obecnosc Candida albicans\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 18416","categories":["pharma"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Candida albicans","search_en":"Cosmetics E Presence of Candida albicans Culture method with biochemical confirmation PN-EN ISO 18416","technique_en":"Culture method with biochemical confirmation","test_object_en":"Cosmetics E","methodology_zh":"白色念珠菌（Candida albicans）检出","search_zh":"化妆品 E 白色念珠菌（Candida albicans）检出 培养法结合生化确认 PN-EN ISO 18416","technique_zh":"培养法结合生化确认","test_object_zh":"化妆品 E"},{"_id":"6a8326c6884ede9a1b2c50e3","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Kosmetyki E","methodology":"Obecność Pseudomonas aeruginosa","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Pseudomonas aeruginosa\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 22717","norm_bases":["PN-EN ISO 22717"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Kosmetyki E Obecność Pseudomonas aeruginosa\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 22717 Kosmetyki E Obecnosc Pseudomonas aeruginosa\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 22717","categories":["pharma"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Pseudomonas aeruginosa","search_en":"Cosmetics E Presence of Pseudomonas aeruginosa Culture method with biochemical confirmation PN-EN ISO 22717","technique_en":"Culture method with biochemical confirmation","test_object_en":"Cosmetics E","methodology_zh":"铜绿假单胞菌（Pseudomonas aeruginosa）检出","search_zh":"化妆品 E 铜绿假单胞菌（Pseudomonas aeruginosa）检出 培养法结合生化确认 PN-EN ISO 22717","technique_zh":"培养法结合生化确认","test_object_zh":"化妆品 E"},{"_id":"6a8326c6884ede9a1b2c50e4","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Kosmetyki E","methodology":"Obecność Escherichia coli","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Escherichia coli\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 21150","norm_bases":["PN-EN ISO 21150"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Kosmetyki E Obecność Escherichia coli\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 21150 Kosmetyki E Obecnosc Escherichia coli\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 21150","categories":["microbiology","pharma"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Escherichia coli","search_en":"Cosmetics E Presence of Escherichia coli Culture method with biochemical confirmation PN-EN ISO 21150","technique_en":"Culture method with biochemical confirmation","test_object_en":"Cosmetics E","methodology_zh":"大肠埃希氏菌（Escherichia coli）检出","search_zh":"化妆品 E 大肠埃希氏菌（Escherichia coli）检出 培养法结合生化确认 PN-EN ISO 21150","technique_zh":"培养法结合生化确认","test_object_zh":"化妆品 E"},{"_id":"6a8326c6884ede9a1b2c50e5","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Kosmetyki E","methodology":"Obecność Staphylococcus aureus","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Staphylococcus aureus\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 22718","norm_bases":["PN-EN ISO 22718"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Kosmetyki E Obecność Staphylococcus aureus\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 22718 Kosmetyki E Obecnosc Staphylococcus aureus\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 22718","categories":["pharma"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Staphylococcus aureus","search_en":"Cosmetics E Presence of Staphylococcus aureus Culture method with biochemical confirmation PN-EN ISO 22718","technique_en":"Culture method with biochemical confirmation","test_object_en":"Cosmetics E","methodology_zh":"金黄色葡萄球菌（Staphylococcus aureus）检出","search_zh":"化妆品 E 金黄色葡萄球菌（Staphylococcus aureus）检出 培养法结合生化确认 PN-EN ISO 22718","technique_zh":"培养法结合生化确认","test_object_zh":"化妆品 E"},{"_id":"6a8326c6884ede9a1b2c50e6","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Chemiczne środki dezynfekcyjne i antyseptyczne E","methodology":"Działanie bakteriobójcze środków dezynfekcyjnych i antyseptycznych","parameters":[],"technique":"Metoda badania: ilościowa zawiesinowa, płytkowa (posiew wgłębny)","techniques":["Metoda badania: ilościowa zawiesinowa, płytkowa (posiew wgłębny)"],"computed":[],"activity":"Działanie bakteriobójcze środków dezynfekcyjnych i antyseptycznych\nMetoda badania: ilościowa zawiesinowa, płytkowa (posiew wgłębny)","reference":"PN-EN 1276","norm_bases":["PN-EN 1276"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Chemiczne środki dezynfekcyjne i antyseptyczne E Działanie bakteriobójcze środków dezynfekcyjnych i antyseptycznych\nMetoda badania: ilościowa zawiesinowa, płytkowa (posiew wgłębny) PN-EN 1276 Chemiczne srodki dezynfekcyjne i antyseptyczne E Dzialanie bakteriobojcze srodkow dezynfekcyjnych i antyseptycznych\nMetoda badania: ilosciowa zawiesinowa, plytkowa (posiew wglebny) PN-EN 1276","categories":["other"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Chemical disinfectants and antiseptics E Test method: quantitative suspension, plate (pour plate) PN-EN 1276","technique_en":"Test method: quantitative suspension, plate (pour plate)","test_object_en":"Chemical disinfectants and antiseptics E","search_zh":"化学消毒剂与防腐剂 E PN-EN 1276","test_object_zh":"化学消毒剂与防腐剂 E"},{"_id":"6a8326c6884ede9a1b2c50e7","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Chemiczne środki dezynfekcyjne i antyseptyczne E","methodology":"Działanie grzybobójcze środków dezynfekcyjnych i antyseptycznych","parameters":[],"technique":"Metoda badania: ilościowa zawiesinowa, płytkowa (posiew wgłębny)","techniques":["Metoda badania: ilościowa zawiesinowa, płytkowa (posiew wgłębny)"],"computed":[],"activity":"Działanie grzybobójcze środków dezynfekcyjnych i antyseptycznych\nMetoda badania: ilościowa zawiesinowa, płytkowa (posiew wgłębny)","reference":"PN-EN 1650","norm_bases":["PN-EN 1650"],"lab_section":"EKOLABOS Sp. z o.o.; Pracownia Mikrobiologii","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Chemiczne środki dezynfekcyjne i antyseptyczne E Działanie grzybobójcze środków dezynfekcyjnych i antyseptycznych\nMetoda badania: ilościowa zawiesinowa, płytkowa (posiew wgłębny) PN-EN 1650 Chemiczne srodki dezynfekcyjne i antyseptyczne E Dzialanie grzybobojcze srodkow dezynfekcyjnych i antyseptycznych\nMetoda badania: ilosciowa zawiesinowa, plytkowa (posiew wglebny) PN-EN 1650","categories":["other"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fungicidal activity of disinfectants and antiseptics","search_en":"Chemical disinfectants and antiseptics E Fungicidal activity of disinfectants and antiseptics Test method: quantitative suspension, plate (pour plate) PN-EN 1650","technique_en":"Test method: quantitative suspension, plate (pour plate)","test_object_en":"Chemical disinfectants and antiseptics E","search_zh":"化学消毒剂与防腐剂 E PN-EN 1650","test_object_zh":"化学消毒剂与防腐剂 E"},{"_id":"6a8326c6884ede9a1b2c50e8","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5","norm_bases":["PN-ISO 5667-5"],"lab_section":"EKOLABOS Sp. z o.o.; Dział Obsługi Klienta","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5 Woda E, Woda do spozycia przez ludzi E Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water E, Water intended for human consumption E Sampling for chemical and physical testing PN-ISO 5667-5","test_object_en":"Water E, Water intended for human consumption E","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 E、生活饮用水 E 化学与物理检测用样品采集 PN-ISO 5667-5","test_object_zh":"水 E、生活饮用水 E"},{"_id":"6a8326c6884ede9a1b2c50e9","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E","methodology":"Pobieranie próbek do analiz mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do analiz mikrobiologicznych","reference":"PN-EN ISO 19458 z wyłączeniem pkt 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458 z wyłączeniem pkt 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6"],"lab_section":"EKOLABOS Sp. z o.o.; Dział Obsługi Klienta","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E Pobieranie próbek do analiz mikrobiologicznych PN-EN ISO 19458 z wyłączeniem pkt 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6 Woda E, Woda do spozycia przez ludzi E Pobieranie probek do analiz mikrobiologicznych PN-EN ISO 19458 z wylaczeniem pkt 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological analyses","search_en":"Water E, Water intended for human consumption E Sampling for microbiological analyses PN-EN ISO 19458 z wyłączeniem pkt 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_en":"Water E, Water intended for human consumption E","search_zh":"水 E、生活饮用水 E 用于微生物分析的采样 PN-EN ISO 19458 z wyłączeniem pkt 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_zh":"水 E、生活饮用水 E","methodology_zh":"用于微生物分析的采样"},{"_id":"6a8326c6884ede9a1b2c50ea","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda na pływalni E","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5 | PO-08/I-02","norm_bases":["PN-ISO 5667-5","PO-08/I-02"],"lab_section":"EKOLABOS Sp. z o.o.; Dział Obsługi Klienta","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda na pływalni E Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5 | PO-08/I-02 Woda na plywalni E Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5 | PO-08/I-02","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Swimming pool water E Sampling for chemical and physical testing PN-ISO 5667-5 | PO-08/I-02","test_object_en":"Swimming pool water E","methodology_zh":"化学与物理检测用样品采集","search_zh":"游泳池水 E 化学与物理检测用样品采集 PN-ISO 5667-5 | PO-08/I-02","test_object_zh":"游泳池水 E"},{"_id":"6a8326c6884ede9a1b2c50eb","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda na pływalni E","methodology":"Pobieranie próbek do analiz mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do analiz mikrobiologicznych","reference":"PN-EN ISO 19458 pkt 4.4.3","norm_bases":["PN-EN ISO 19458 pkt 4.4.3"],"lab_section":"EKOLABOS Sp. z o.o.; Dział Obsługi Klienta","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda na pływalni E Pobieranie próbek do analiz mikrobiologicznych PN-EN ISO 19458 pkt 4.4.3 Woda na plywalni E Pobieranie probek do analiz mikrobiologicznych PN-EN ISO 19458 pkt 4.4.3","categories":["water","microbiology"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological analyses","search_en":"Swimming pool water E Sampling for microbiological analyses PN-EN ISO 19458 pkt 4.4.3","test_object_en":"Swimming pool water E","methodology_zh":"用于微生物分析的采样","search_zh":"游泳池水 E 用于微生物分析的采样 PN-EN ISO 19458 pkt 4.4.3","test_object_zh":"游泳池水 E"},{"_id":"6a8326c6884ede9a1b2c50ec","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda E, Woda do spożycia przez ludzi E, Woda na pływalni E","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,10 – 3,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,10 – 3,0) mg/l\nMetoda spektrofotometryczna","reference":"Test Merck 1.00599.0001","norm_bases":["Test Merck 1.00599.0001"],"lab_section":"EKOLABOS Sp. z o.o.; Dział Obsługi Klienta","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E, Woda do spożycia przez ludzi E, Woda na pływalni E Stężenie chloru wolnego\nZakres (0,10 – 3,0) mg/l\nMetoda spektrofotometryczna Test Merck 1.00599.0001 Woda E, Woda do spozycia przez ludzi E, Woda na plywalni E Stezenie chloru wolnego\nZakres (0,10 – 3,0) mg/l\nMetoda spektrofotometryczna Test Merck 1.00599.0001","categories":["water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,10 – 3,0) mg/l"}],"search_en":"Water E, Water intended for human consumption E, Swimming pool water E Free chlorine concentration Spectrophotometric method Range Test Merck 1.00599.0001","technique_en":"Spectrophotometric method","test_object_en":"Water E, Water intended for human consumption E, Swimming pool water E","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 3,0) mg/l"}],"search_zh":"游离氯浓度 分光光度法 范围 Test Merck 1.00599.0001","technique_zh":"分光光度法"},{"_id":"6a8326c6884ede9a1b2c50ed","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda na pływalni E","methodology":"Stężenie chloru ogólnego","parameters":[{"name":"Zakres","range":"(0,10 – 3,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru ogólnego\nZakres (0,10 – 3,0) mg/l\nMetoda spektrofotometryczna","reference":"Test Merck 1.00599.0001","norm_bases":["Test Merck 1.00599.0001"],"lab_section":"EKOLABOS Sp. z o.o.; Dział Obsługi Klienta","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda na pływalni E Stężenie chloru ogólnego\nZakres (0,10 – 3,0) mg/l\nMetoda spektrofotometryczna Test Merck 1.00599.0001 Woda na plywalni E Stezenie chloru ogolnego\nZakres (0,10 – 3,0) mg/l\nMetoda spektrofotometryczna Test Merck 1.00599.0001","categories":["water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chlorine concentration","parameters_en":[{"name":"Range","range":"(0,10 – 3,0) mg/l"}],"search_en":"Swimming pool water E Total chlorine concentration Spectrophotometric method Range Test Merck 1.00599.0001","technique_en":"Spectrophotometric method","test_object_en":"Swimming pool water E","parameters_zh":[{"name":"范围","range":"(0,10 – 3,0) mg/l"}],"search_zh":"游泳池水 E 总氯浓度 分光光度法 范围 Test Merck 1.00599.0001","technique_zh":"分光光度法","methodology_zh":"总氯浓度","test_object_zh":"游泳池水 E"},{"_id":"6a8326c6884ede9a1b2c50ee","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda na pływalni E","methodology":"Stężenie chloru związanego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloru związanego (z obliczeń)","reference":"Test Merck 1.00599.0001","norm_bases":["Test Merck 1.00599.0001"],"lab_section":"EKOLABOS Sp. z o.o.; Dział Obsługi Klienta","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda na pływalni E Stężenie chloru związanego (z obliczeń) Test Merck 1.00599.0001 Woda na plywalni E Stezenie chloru zwiazanego (z obliczen) Test Merck 1.00599.0001","categories":["water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Combined chlorine concentration (calculated)","search_en":"Swimming pool water E Combined chlorine concentration (calculated) Test Merck 1.00599.0001","test_object_en":"Swimming pool water E","methodology_zh":"化合氯浓度（计算值）","search_zh":"游泳池水 E 化合氯浓度（计算值） Test Merck 1.00599.0001","test_object_zh":"游泳池水 E"},{"_id":"6a8326c6884ede9a1b2c50ef","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda na pływalni E","methodology":"Potencjał utleniająco – redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl","parameters":[{"name":"Zakres","range":"(200 – 800) mV"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Potencjał utleniająco – redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (200 – 800) mV\nMetoda potencjometryczna","reference":"PB-25","norm_bases":["PB-25"],"lab_section":"EKOLABOS Sp. z o.o.; Dział Obsługi Klienta","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda na pływalni E Potencjał utleniająco – redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (200 – 800) mV\nMetoda potencjometryczna PB-25 Woda na plywalni E Potencjal utleniajaco – redukujacy (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (200 – 800) mV\nMetoda potencjometryczna PB-25","categories":["water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation-reduction (redox) potential ref. to Ag/AgCl 3,5 mol/l KCl","parameters_en":[{"name":"Range","range":"(200 – 800) mV"}],"search_en":"Swimming pool water E Oxidation-reduction (redox) potential ref. to Ag/AgCl 3,5 mol/l KCl Potentiometric method Range PB-25","technique_en":"Potentiometric method","test_object_en":"Swimming pool water E","parameters_zh":[{"name":"范围","range":"(200 – 800) mV"}],"search_zh":"游泳池水 E 电位法 范围 PB-25","technique_zh":"电位法","test_object_zh":"游泳池水 E"},{"_id":"6a8326c6884ede9a1b2c50f0","lab_id":"69ad52a3de79e566650fba13","country":"PL","accr_number":"AB 1868","accr_body":"PCA","test_object":"Woda na pływalni E","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523","norm_bases":["PN-EN ISO 10523"],"lab_section":"EKOLABOS Sp. z o.o.; Dział Obsługi Klienta","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji udostępniana jest publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda na pływalni E pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523 Woda na plywalni E pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523","categories":["water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 10,0"}],"search_en":"Swimming pool water E pH Potentiometric method Range PN-EN ISO 10523","technique_en":"Potentiometric method","test_object_en":"Swimming pool water E","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 10,0"}],"search_zh":"游泳池水 E pH 值 电位法 范围 PN-EN ISO 10523","technique_zh":"电位法","test_object_zh":"游泳池水 E"}],"has_pdf":true}