{"lab":{"_id":"69ad52a3de79e566650fba11","accr_number":"AB 1867","country":"PL","accr_body":"PCA","address":"ul. Malwowa 6, Bolechówko, 62-005 Owińska","categories":["construction","water"],"city":"Owińska","imported_at":"2026-03-08T10:42:43.265Z","methods_count":7,"name":"FIRMA GEOLOGICZNA FELKEL & GUŚ SP. Z O.O.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1867.pdf"],"scope_summary":"","search_text":"firma geologiczna felkel & guś sp. z o.o. ul. malwowa 6, bolechówko, 62-005 owińska construction other water","status":"active","updated_at":"2026-03-08T14:50:59.822Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:59.822Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201867,podmiot.html","fields_of_testing":[{"codes":"J/5/P","pl":"Badania mechaniczne i pobieranie próbek wyrobów i materiałów budowlanych","en":"Mechanical tests and sampling of building products and materials"},{"codes":"J/5","pl":"Badania mechaniczne wyrobów i materiałów budowlanych","en":"Mechanical tests of building products and materials"},{"codes":"N/5/P","pl":"Badania właściwości fizycznych i pobieranie próbek wyrobów i materiałów budowlanych","en":"Tests of physical properties and sampling of building products and materials"},{"codes":"N/5","pl":"Badania właściwości fizycznych wyrobów i materiałów budowlanych","en":"Tests of physical properties of building products and materials"},{"codes":"P/5","pl":"Pobieranie próbek wyrobów i materiałów budowlanych","en":"Sampling of building products and materials"}],"issue":{"no":"1","date":"03.07.2023"},"parse_date":"2026-07-20T07:09:30.868Z","parse_source":"script-pdfplumber","map_coord":[52.513926,16.972517],"map_geo":"nominatim-city","has_zh":true,"has_en":true,"category_counts":{"construction":7,"water":2},"category_scores":{"construction":5.44,"water":0.44}},"methods":[{"_id":"6a5dc9aaf1c10c8ce825a2c7","lab_id":"69ad52a3de79e566650fba11","country":"PL","accr_number":"AB 1867","accr_body":"PCA","test_object":"Mieszanka betonowa","test_object_en":"Fresh concrete","methodology":"Konsystencja","methodology_en":"Consistency","parameters":[],"parameters_en":[],"technique":"Metoda opadu stożka","techniques":["Metoda opadu stożka"],"technique_en":"Slump test method","computed":[],"computed_en":[],"activity":"Konsystencja\nMetoda opadu stożka","reference":"PN-EN 12350-2:2019-07","norm_bases":["PN-EN 12350-2:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mieszanka betonowa Konsystencja\nMetoda opadu stożka PN-EN 12350-2:2019-07 Mieszanka betonowa Konsystencja\nMetoda opadu stozka PN-EN 12350-2:2019-07","categories":["construction"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"稠度","search_zh":"混凝土拌合物 稠度 坍落度法 PN-EN 12350-2:2019-07","technique_zh":"坍落度法","test_object_zh":"混凝土拌合物","search_en":"Fresh concrete Consistency Slump test method PN-EN 12350-2:2019-07"},{"_id":"6a5dc9aaf1c10c8ce825a2c8","lab_id":"69ad52a3de79e566650fba11","country":"PL","accr_number":"AB 1867","accr_body":"PCA","test_object":"Mieszanka betonowa","test_object_en":"Fresh concrete","methodology":"Zawartość powietrza","methodology_en":"Air content","parameters":[],"parameters_en":[],"technique":"Metoda ciśnieniomierza","techniques":["Metoda ciśnieniomierza"],"technique_en":"Pressure gauge method","computed":[],"computed_en":[],"activity":"Zawartość powietrza\nMetoda ciśnieniomierza","reference":"PN-EN 12350-7:2019-08","norm_bases":["PN-EN 12350-7:2019-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mieszanka betonowa Zawartość powietrza\nMetoda ciśnieniomierza PN-EN 12350-7:2019-08 Mieszanka betonowa Zawartosc powietrza\nMetoda cisnieniomierza PN-EN 12350-7:2019-08","categories":["construction"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"含气量","search_zh":"混凝土拌合物 含气量 压力计法 PN-EN 12350-7:2019-08","technique_zh":"压力计法","test_object_zh":"混凝土拌合物","search_en":"Fresh concrete Air content Pressure gauge method PN-EN 12350-7:2019-08"},{"_id":"6a5dc9aaf1c10c8ce825a2c9","lab_id":"69ad52a3de79e566650fba11","country":"PL","accr_number":"AB 1867","accr_body":"PCA","test_object":"Mieszanka betonowa","test_object_en":"Fresh concrete","methodology":"Pobieranie próbek","methodology_en":"Sampling","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek","reference":"PN-EN 12350-1:2019-07","norm_bases":["PN-EN 12350-1:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mieszanka betonowa Pobieranie próbek PN-EN 12350-1:2019-07 Mieszanka betonowa Pobieranie probek PN-EN 12350-1:2019-07","categories":["construction"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"样品采集","search_zh":"混凝土拌合物 样品采集 PN-EN 12350-1:2019-07","test_object_zh":"混凝土拌合物","search_en":"Fresh concrete Sampling PN-EN 12350-1:2019-07"},{"_id":"6a5dc9aaf1c10c8ce825a2ca","lab_id":"69ad52a3de79e566650fba11","country":"PL","accr_number":"AB 1867","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres","range":"(100 - 3000) kN"}],"parameters_en":[{"name":"Range","range":"(100 - 3000) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres (100 - 3000) kN","reference":"PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12390-3:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Wytrzymałość na ściskanie\nZakres (100 - 3000) kN PN-EN 12390-3:2019-07 Beton Wytrzymalosc na sciskanie\nZakres (100 - 3000) kN PN-EN 12390-3:2019-07","categories":["construction"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(100 - 3000) kN"}],"search_zh":"混凝土 抗压强度 范围 PN-EN 12390-3:2019-07","test_object_zh":"混凝土","search_en":"Concrete Compressive strength Range PN-EN 12390-3:2019-07"},{"_id":"6a5dc9aaf1c10c8ce825a2cb","lab_id":"69ad52a3de79e566650fba11","country":"PL","accr_number":"AB 1867","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Gęstość","methodology_en":"Density","parameters":[],"parameters_en":[],"technique":"Metoda objętościowo-wagowa","techniques":["Metoda objętościowo-wagowa"],"technique_en":"Volumetric-gravimetric method","computed":[],"computed_en":[],"activity":"Gęstość\nMetoda objętościowo-wagowa","reference":"PN-EN 12390-7:2019-08 z wyłączeniem p. 6.5 | PN-EN 12390-7:2019-08/AC:2021-01","norm_bases":["PN-EN 12390-7:2019-08 z wyłączeniem p. 6.5","PN-EN 12390-7:2019-08/AC:2021-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Gęstość\nMetoda objętościowo-wagowa PN-EN 12390-7:2019-08 z wyłączeniem p. 6.5 | PN-EN 12390-7:2019-08/AC:2021-01 Beton Gestosc\nMetoda objetosciowo-wagowa PN-EN 12390-7:2019-08 z wylaczeniem p. 6.5 | PN-EN 12390-7:2019-08/AC:2021-01","categories":["construction"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"密度","search_zh":"混凝土 密度 容量-重量法 PN-EN 12390-7:2019-08 z wyłączeniem p. 6.5 | PN-EN 12390-7:2019-08/AC:2021-01","technique_zh":"容量-重量法","test_object_zh":"混凝土","search_en":"Concrete Density Volumetric-gravimetric method PN-EN 12390-7:2019-08 z wyłączeniem p. 6.5 | PN-EN 12390-7:2019-08/AC:2021-01"},{"_id":"6a5dc9aaf1c10c8ce825a2cc","lab_id":"69ad52a3de79e566650fba11","country":"PL","accr_number":"AB 1867","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Przepuszczalność wody","methodology_en":"Water permeability","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność wody","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Przepuszczalność wody PN-88/B-06250 Beton Przepuszczalnosc wody PN-88/B-06250","categories":["water","construction"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"透水性","search_zh":"混凝土 透水性 PN-88/B-06250","test_object_zh":"混凝土","search_en":"Concrete Water permeability PN-88/B-06250"},{"_id":"6a5dc9aaf1c10c8ce825a2cd","lab_id":"69ad52a3de79e566650fba11","country":"PL","accr_number":"AB 1867","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Głębokość penetracji wody pod ciśnieniem","methodology_en":"Depth of penetration of water under pressure","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Głębokość penetracji wody pod ciśnieniem","reference":"PN-EN 12390-8:2019-08","norm_bases":["PN-EN 12390-8:2019-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Głębokość penetracji wody pod ciśnieniem PN-EN 12390-8:2019-08 Beton Glebokosc penetracji wody pod cisnieniem PN-EN 12390-8:2019-08","categories":["water","construction"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","methodology_zh":"压力水渗透深度","search_zh":"混凝土 压力水渗透深度 PN-EN 12390-8:2019-08","test_object_zh":"混凝土","search_en":"Concrete Depth of penetration of water under pressure PN-EN 12390-8:2019-08"}],"has_pdf":true}