{"lab":{"_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","address":"Laboratorium Kontroli Jakości Mikrobiologia, ul. Vetterów 5, 20-277 Lublin","categories":["microbiology","construction"],"city":"Lublin","imported_at":"2026-03-08T10:42:43.265Z","methods_count":25,"name":"BioMaxima S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1863.pdf"],"scope_summary":"","search_text":"biomaxima s.a. laboratorium kontroli jakości mikrobiologia, ul. vetterów 5, 20-277 lublin construction microbiology pharma other automotive water food","status":"active","updated_at":"2026-03-08T14:50:59.631Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T15:21:26.258Z","location":{"type":"Point","coordinates":[22.5684,51.2465]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201863,podmiot.html","fields_of_testing":[{"codes":"K/17","pl":"Badania mikrobiologiczne wyrobów innych (pożywki mikrobiologiczne)","en":"Microbiological tests of other products (microbiological culture media)","de":"Mikrobiologische Prüfungen sonstiger Erzeugnisse (mikrobiologische Nährmedien)","zh":"其他产品（微生物培养基）的微生物检测","cs":"Mikrobiologické zkoušky jiných výrobků (mikrobiologické živné půdy)"}],"issue":{"no":"3","date":"30.07.2026"},"parse_date":"2026-08-17T15:21:26.258Z","parse_source":"agent-claude-code","map_coord":[51.223833,22.642332],"map_geo":"nominatim-street","lab_locations":[{"code":null,"name":"BioMaxima S.A.","street":"ul. Vetterów 5","postal_code":"20-277","city":"Lublin","is_hq":true,"address":"ul. Vetterów 5, 20-277 Lublin","site":"20-277|vetterów5"},{"code":null,"name":"Laboratorium Kontroli Jakości Mikrobiologia","street":"ul. Vetterów 5","postal_code":"20-277","city":"Lublin","is_hq":false,"address":"ul. Vetterów 5, 20-277 Lublin","site":"20-277|vetterów5"}],"scope_format":"PCA::pracownie+siatka6","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/9964b4324c092809cde2caf005ff0abe/AB%201863.pdf","has_en":true,"category_counts":{"microbiology":21,"construction":12,"other":2,"water":1},"category_scores":{"microbiology":12.25,"construction":4,"other":0.11,"water":0.03},"has_zh":true,"lab_locations_en":[{"code":null,"name":"BioMaxima S.A.","street":"ul. Vetterów 5","postal_code":"20-277","city":"Lublin","is_hq":true,"address":"ul. Vetterów 5, 20-277 Lublin","site":"20-277|vetterów5"},{"code":null,"name":"Microbiology Quality Control Laboratory","street":"ul. Vetterów 5","postal_code":"20-277","city":"Lublin","is_hq":false,"address":"ul. Vetterów 5, 20-277 Lublin","site":"20-277|vetterów5"}],"has_de":true,"lab_locations_de":[{"code":null,"name":"BioMaxima S.A.","street":"ul. Vetterów 5","postal_code":"20-277","city":"Lublin","is_hq":true,"address":"ul. Vetterów 5, 20-277 Lublin","site":"20-277|vetterów5"},{"code":null,"name":"Qualitätskontrolllabor Mikrobiologie","street":"ul. Vetterów 5","postal_code":"20-277","city":"Lublin","is_hq":false,"address":"ul. Vetterów 5, 20-277 Lublin","site":"20-277|vetterów5"}],"lab_locations_zh":[{"code":null,"name":"BioMaxima S.A.","street":"ul. Vetterów 5","postal_code":"20-277","city":"Lublin","is_hq":true,"address":"ul. Vetterów 5, 20-277 Lublin","site":"20-277|vetterów5"},{"code":null,"name":"质量控制实验室 微生物","street":"ul. Vetterów 5","postal_code":"20-277","city":"Lublin","is_hq":false,"address":"ul. Vetterów 5, 20-277 Lublin","site":"20-277|vetterów5"}],"has_cs":true,"lab_locations_cs":[{"code":null,"name":"BioMaxima S.A.","street":"ul. Vetterów 5","postal_code":"20-277","city":"Lublin","is_hq":true,"address":"ul. Vetterów 5, 20-277 Lublin","site":"20-277|vetterów5"},{"code":null,"name":"Laboratoř kontroly kvality Mikrobiologie","street":"ul. Vetterów 5","postal_code":"20-277","city":"Lublin","is_hq":false,"address":"ul. Vetterów 5, 20-277 Lublin","site":"20-277|vetterów5"}],"pelny_cs":true},"methods":[{"_id":"6a8326f6884ede9a1b2c5138","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka agarowa wybiórczo-różnicująca stosowana do izolacji i identyfikacji drobnoustrojów, XLD LAB-AGAR™, Salmonella Shigella LAB-AGAR™, BGA LAB-AGAR™ acc. to ISO 6579, Chromogenic Candida LAB-AGARTM, Chromogenic KPC Mod. LAB-AGAR™, Chromogenic ESBL Mod. LAB-AGAR™, Chromogenic Strepto B LAB-AGAR™, Chromogenic MRSA LAB-AGAR™, Chromogenic S. aureus Modified LAB-AGAR™, Yersinia CIN LAB-AGAR™, Palcam Listeria LAB-AGAR™, CHROMagar™ Salmonella PLUS, Chromogenic VRE LAB-AGAR™","methodology":"Żyzność","parameters":[{"name":"Żyzność","range":null}],"technique":"Metoda jakościowa, płytkowa (posiew rysowy, redukcyjny)","techniques":["Metoda jakościowa, płytkowa (posiew rysowy, redukcyjny)"],"computed":[],"activity":"Żyzność\nMetoda jakościowa, płytkowa (posiew rysowy, redukcyjny)","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 6579","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10","ISO 6579"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka agarowa wybiórczo-różnicująca stosowana do izolacji i identyfikacji drobnoustrojów, XLD LAB-AGAR™, Salmonella Shigella LAB-AGAR™, BGA LAB-AGAR™ acc. to ISO 6579, Chromogenic Candida LAB-AGARTM, Chromogenic KPC Mod. LAB-AGAR™, Chromogenic ESBL Mod. LAB-AGAR™, Chromogenic Strepto B LAB-AGAR™, Chromogenic MRSA LAB-AGAR™, Chromogenic S. aureus Modified LAB-AGAR™, Yersinia CIN LAB-AGAR™, Palcam Listeria LAB-AGAR™, CHROMagar™ Salmonella PLUS, Chromogenic VRE LAB-AGAR™ Żyzność\nMetoda jakościowa, płytkowa (posiew rysowy, redukcyjny) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 6579 Pozywka agarowa wybiorczo-roznicujaca stosowana do izolacji i identyfikacji drobnoustrojow, XLD LAB-AGAR™, Salmonella Shigella LAB-AGAR™, BGA LAB-AGAR™ acc. to ISO 6579, Chromogenic Candida LAB-AGARTM, Chromogenic KPC Mod. LAB-AGAR™, Chromogenic ESBL Mod. LAB-AGAR™, Chromogenic Strepto B LAB-AGAR™, Chromogenic MRSA LAB-AGAR™, Chromogenic S. aureus Modified LAB-AGAR™, Yersinia CIN LAB-AGAR™, Palcam Listeria LAB-AGAR™, CHROMagar™ Salmonella PLUS, Chromogenic VRE LAB-AGAR™ Zyznosc\nMetoda jakosciowa, plytkowa (posiew rysowy, redukcyjny) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 6579","categories":["microbiology","construction"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fertility","parameters_en":[{"name":"Fertility","range":null}],"search_en":"Selective-differential agar medium used for the isolation and identification of microorganisms, XLD LAB-AGAR™, Salmonella Shigella LAB-AGAR™, BGA LAB-AGAR™ acc. to ISO 6579, Chromogenic Candida LAB-AGARTM, Chromogenic KPC Mod. LAB-AGAR™, Chromogenic ESBL Mod. LAB-AGAR™, Chromogenic Strepto B LAB-AGAR™, Chromogenic MRSA LAB-AGAR™, Chromogenic S. aureus Modified LAB-AGAR™, Yersinia CIN LAB-AGAR™, Palcam Listeria LAB-AGAR™, CHROMagar™ Salmonella PLUS, Chromogenic VRE LAB-AGAR™ Fertility Qualitative plate method (streak plate, reductive streak) Microbiology Quality Control Laboratory Qualitative plate method (streak plate, reductive streak) Fertility PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 6579","technique_en":"Qualitative plate method (streak plate, reductive streak)","methodology_zh":"肥力","parameters_zh":[{"name":"肥力","range":null}],"search_zh":"用于微生物分离和鉴定的选择性鉴别琼脂培养基， XLD LAB-AGAR™, Salmonella Shigella LAB-AGAR™, BGA LAB-AGAR™ acc. to ISO 6579, Chromogenic Candida LAB-AGARTM, Chromogenic KPC Mod. LAB-AGAR™, Chromogenic ESBL Mod. LAB-AGAR™, Chromogenic Strepto B LAB-AGAR™, Chromogenic MRSA LAB-AGAR™, Chromogenic S. aureus Modified LAB-AGAR™, Yersinia CIN LAB-AGAR™, Palcam Listeria LAB-AGAR™, CHROMagar™ Salmonella PLUS, Chromogenic VRE LAB-AGAR™ 肥力 定性平板法（划线、稀释接种） 质量控制实验室 微生物 定性平板法（划线、稀释接种） 肥力 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 6579","technique_zh":"定性平板法（划线、稀释接种）","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Qualitative plate method (streak plate, reductive streak)"],"test_object_en":"Selective-differential agar medium used for the isolation and identification of microorganisms, XLD LAB-AGAR™, Salmonella Shigella LAB-AGAR™, BGA LAB-AGAR™ acc. to ISO 6579, Chromogenic Candida LAB-AGARTM, Chromogenic KPC Mod. LAB-AGAR™, Chromogenic ESBL Mod. LAB-AGAR™, Chromogenic Strepto B LAB-AGAR™, Chromogenic MRSA LAB-AGAR™, Chromogenic S. aureus Modified LAB-AGAR™, Yersinia CIN LAB-AGAR™, Palcam Listeria LAB-AGAR™, CHROMagar™ Salmonella PLUS, Chromogenic VRE LAB-AGAR™","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Bodenfruchtbarkeit","parameters_de":[{"name":"Bodenfruchtbarkeit","range":null}],"search_de":"Selektiv-differenzierender Agarnährboden zur Isolierung und Identifizierung von Mikroorganismen, XLD LAB-AGAR™, Salmonella Shigella LAB-AGAR™, BGA LAB-AGAR™ acc. to ISO 6579, Chromogenic Candida LAB-AGARTM, Chromogenic KPC Mod. LAB-AGAR™, Chromogenic ESBL Mod. LAB-AGAR™, Chromogenic Strepto B LAB-AGAR™, Chromogenic MRSA LAB-AGAR™, Chromogenic S. aureus Modified LAB-AGAR™, Yersinia CIN LAB-AGAR™, Palcam Listeria LAB-AGAR™, CHROMagar™ Salmonella PLUS, Chromogenic VRE LAB-AGAR™ Bodenfruchtbarkeit Qualitatives Verfahren, Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren) Qualitätskontrolllabor Mikrobiologie Qualitatives Verfahren, Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren) Bodenfruchtbarkeit PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 6579","technique_de":"Qualitatives Verfahren, Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren)","techniques_de":["Qualitatives Verfahren, Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren)"],"test_object_de":"Selektiv-differenzierender Agarnährboden zur Isolierung und Identifizierung von Mikroorganismen, XLD LAB-AGAR™, Salmonella Shigella LAB-AGAR™, BGA LAB-AGAR™ acc. to ISO 6579, Chromogenic Candida LAB-AGARTM, Chromogenic KPC Mod. LAB-AGAR™, Chromogenic ESBL Mod. LAB-AGAR™, Chromogenic Strepto B LAB-AGAR™, Chromogenic MRSA LAB-AGAR™, Chromogenic S. aureus Modified LAB-AGAR™, Yersinia CIN LAB-AGAR™, Palcam Listeria LAB-AGAR™, CHROMagar™ Salmonella PLUS, Chromogenic VRE LAB-AGAR™","lab_section_zh":"质量控制实验室 微生物","techniques_zh":["定性平板法（划线、稀释接种）"],"test_object_zh":"用于微生物分离和鉴定的选择性鉴别琼脂培养基， XLD LAB-AGAR™, Salmonella Shigella LAB-AGAR™, BGA LAB-AGAR™ acc. to ISO 6579, Chromogenic Candida LAB-AGARTM, Chromogenic KPC Mod. LAB-AGAR™, Chromogenic ESBL Mod. LAB-AGAR™, Chromogenic Strepto B LAB-AGAR™, Chromogenic MRSA LAB-AGAR™, Chromogenic S. aureus Modified LAB-AGAR™, Yersinia CIN LAB-AGAR™, Palcam Listeria LAB-AGAR™, CHROMagar™ Salmonella PLUS, Chromogenic VRE LAB-AGAR™","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Úrodnost","parameters_cs":[{"name":"Úrodnost","range":null}],"search_cs":"Selektivně-diferenciační agarová živná půda používaná k izolaci a identifikaci mikroorganismů, XLD LAB-AGAR™, Salmonella Shigella LAB-AGAR™, BGA LAB-AGAR™ acc. to ISO 6579, Chromogenic Candida LAB-AGARTM, Chromogenic KPC Mod. LAB-AGAR™, Chromogenic ESBL Mod. LAB-AGAR™, Chromogenic Strepto B LAB-AGAR™, Chromogenic MRSA LAB-AGAR™, Chromogenic S. aureus Modified LAB-AGAR™, Yersinia CIN LAB-AGAR™, Palcam Listeria LAB-AGAR™, CHROMagar™ Salmonella PLUS, Chromogenic VRE LAB-AGAR™ Úrodnost Kvalitativní metoda, plotnová (křížový roztěr, redukční) Laboratoř kontroly kvality Mikrobiologie Kvalitativní metoda, plotnová (křížový roztěr, redukční) Úrodnost PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 6579","technique_cs":"Kvalitativní metoda, plotnová (křížový roztěr, redukční)","techniques_cs":["Kvalitativní metoda, plotnová (křížový roztěr, redukční)"],"test_object_cs":"Selektivně-diferenciační agarová živná půda používaná k izolaci a identifikaci mikroorganismů, XLD LAB-AGAR™, Salmonella Shigella LAB-AGAR™, BGA LAB-AGAR™ acc. to ISO 6579, Chromogenic Candida LAB-AGARTM, Chromogenic KPC Mod. LAB-AGAR™, Chromogenic ESBL Mod. LAB-AGAR™, Chromogenic Strepto B LAB-AGAR™, Chromogenic MRSA LAB-AGAR™, Chromogenic S. aureus Modified LAB-AGAR™, Yersinia CIN LAB-AGAR™, Palcam Listeria LAB-AGAR™, CHROMagar™ Salmonella PLUS, Chromogenic VRE LAB-AGAR™"},{"_id":"6a8326f6884ede9a1b2c5139","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka agarowa wybiórczo-różnicująca stosowana do izolacji i identyfikacji drobnoustrojów, XLD LAB-AGAR™, Salmonella Shigella LAB-AGAR™, BGA LAB-AGAR™ acc. to ISO 6579, Chromogenic Candida LAB-AGARTM, Chromogenic KPC Mod. LAB-AGAR™, Chromogenic ESBL Mod. LAB-AGAR™, Chromogenic Strepto B LAB-AGAR™, Chromogenic MRSA LAB-AGAR™, Chromogenic S. aureus Modified LAB-AGAR™, Yersinia CIN LAB-AGAR™, Palcam Listeria LAB-AGAR™, CHROMagar™ Salmonella PLUS, Chromogenic VRE LAB-AGAR™","methodology":"Selektywność","parameters":[{"name":"Selektywność","range":null}],"technique":"Metoda jakościowa, płytkowa (posiew rysowy)","techniques":["Metoda jakościowa, płytkowa (posiew rysowy)"],"computed":[],"activity":"Selektywność\nMetoda jakościowa, płytkowa (posiew rysowy)","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 6579","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10","ISO 6579"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka agarowa wybiórczo-różnicująca stosowana do izolacji i identyfikacji drobnoustrojów, XLD LAB-AGAR™, Salmonella Shigella LAB-AGAR™, BGA LAB-AGAR™ acc. to ISO 6579, Chromogenic Candida LAB-AGARTM, Chromogenic KPC Mod. LAB-AGAR™, Chromogenic ESBL Mod. LAB-AGAR™, Chromogenic Strepto B LAB-AGAR™, Chromogenic MRSA LAB-AGAR™, Chromogenic S. aureus Modified LAB-AGAR™, Yersinia CIN LAB-AGAR™, Palcam Listeria LAB-AGAR™, CHROMagar™ Salmonella PLUS, Chromogenic VRE LAB-AGAR™ Selektywność\nMetoda jakościowa, płytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 6579 Pozywka agarowa wybiorczo-roznicujaca stosowana do izolacji i identyfikacji drobnoustrojow, XLD LAB-AGAR™, Salmonella Shigella LAB-AGAR™, BGA LAB-AGAR™ acc. to ISO 6579, Chromogenic Candida LAB-AGARTM, Chromogenic KPC Mod. LAB-AGAR™, Chromogenic ESBL Mod. LAB-AGAR™, Chromogenic Strepto B LAB-AGAR™, Chromogenic MRSA LAB-AGAR™, Chromogenic S. aureus Modified LAB-AGAR™, Yersinia CIN LAB-AGAR™, Palcam Listeria LAB-AGAR™, CHROMagar™ Salmonella PLUS, Chromogenic VRE LAB-AGAR™ Selektywnosc\nMetoda jakosciowa, plytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 6579","categories":["microbiology","construction"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Selectivity","parameters_en":[{"name":"Selectivity","range":null}],"search_en":"Selective-differential agar medium used for the isolation and identification of microorganisms, XLD LAB-AGAR™, Salmonella Shigella LAB-AGAR™, BGA LAB-AGAR™ acc. to ISO 6579, Chromogenic Candida LAB-AGARTM, Chromogenic KPC Mod. LAB-AGAR™, Chromogenic ESBL Mod. LAB-AGAR™, Chromogenic Strepto B LAB-AGAR™, Chromogenic MRSA LAB-AGAR™, Chromogenic S. aureus Modified LAB-AGAR™, Yersinia CIN LAB-AGAR™, Palcam Listeria LAB-AGAR™, CHROMagar™ Salmonella PLUS, Chromogenic VRE LAB-AGAR™ Selectivity Qualitative plate method (streak plate) Microbiology Quality Control Laboratory Qualitative plate method (streak plate) Selectivity PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 6579","technique_en":"Qualitative plate method (streak plate)","methodology_zh":"选择性","parameters_zh":[{"name":"选择性","range":null}],"search_zh":"用于微生物分离和鉴定的选择性鉴别琼脂培养基， XLD LAB-AGAR™, Salmonella Shigella LAB-AGAR™, BGA LAB-AGAR™ acc. to ISO 6579, Chromogenic Candida LAB-AGARTM, Chromogenic KPC Mod. LAB-AGAR™, Chromogenic ESBL Mod. LAB-AGAR™, Chromogenic Strepto B LAB-AGAR™, Chromogenic MRSA LAB-AGAR™, Chromogenic S. aureus Modified LAB-AGAR™, Yersinia CIN LAB-AGAR™, Palcam Listeria LAB-AGAR™, CHROMagar™ Salmonella PLUS, Chromogenic VRE LAB-AGAR™ 选择性 定性平板法（划线接种） 质量控制实验室 微生物 定性平板法（划线接种） 选择性 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 6579","technique_zh":"定性平板法（划线接种）","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Qualitative plate method (streak plate)"],"test_object_en":"Selective-differential agar medium used for the isolation and identification of microorganisms, XLD LAB-AGAR™, Salmonella Shigella LAB-AGAR™, BGA LAB-AGAR™ acc. to ISO 6579, Chromogenic Candida LAB-AGARTM, Chromogenic KPC Mod. LAB-AGAR™, Chromogenic ESBL Mod. LAB-AGAR™, Chromogenic Strepto B LAB-AGAR™, Chromogenic MRSA LAB-AGAR™, Chromogenic S. aureus Modified LAB-AGAR™, Yersinia CIN LAB-AGAR™, Palcam Listeria LAB-AGAR™, CHROMagar™ Salmonella PLUS, Chromogenic VRE LAB-AGAR™","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Selektivität","parameters_de":[{"name":"Selektivität","range":null}],"search_de":"Selektiv-differenzierender Agarnährboden zur Isolierung und Identifizierung von Mikroorganismen, XLD LAB-AGAR™, Salmonella Shigella LAB-AGAR™, BGA LAB-AGAR™ acc. to ISO 6579, Chromogenic Candida LAB-AGARTM, Chromogenic KPC Mod. LAB-AGAR™, Chromogenic ESBL Mod. LAB-AGAR™, Chromogenic Strepto B LAB-AGAR™, Chromogenic MRSA LAB-AGAR™, Chromogenic S. aureus Modified LAB-AGAR™, Yersinia CIN LAB-AGAR™, Palcam Listeria LAB-AGAR™, CHROMagar™ Salmonella PLUS, Chromogenic VRE LAB-AGAR™ Selektivität Qualitatives Verfahren, Plattenverfahren (Ausstrichverfahren) Qualitätskontrolllabor Mikrobiologie Qualitatives Verfahren, Plattenverfahren (Ausstrichverfahren) Selektivität PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 6579","technique_de":"Qualitatives Verfahren, Plattenverfahren (Ausstrichverfahren)","techniques_de":["Qualitatives Verfahren, Plattenverfahren (Ausstrichverfahren)"],"test_object_de":"Selektiv-differenzierender Agarnährboden zur Isolierung und Identifizierung von Mikroorganismen, XLD LAB-AGAR™, Salmonella Shigella LAB-AGAR™, BGA LAB-AGAR™ acc. to ISO 6579, Chromogenic Candida LAB-AGARTM, Chromogenic KPC Mod. LAB-AGAR™, Chromogenic ESBL Mod. LAB-AGAR™, Chromogenic Strepto B LAB-AGAR™, Chromogenic MRSA LAB-AGAR™, Chromogenic S. aureus Modified LAB-AGAR™, Yersinia CIN LAB-AGAR™, Palcam Listeria LAB-AGAR™, CHROMagar™ Salmonella PLUS, Chromogenic VRE LAB-AGAR™","lab_section_zh":"质量控制实验室 微生物","techniques_zh":["定性平板法（划线接种）"],"test_object_zh":"用于微生物分离和鉴定的选择性鉴别琼脂培养基， XLD LAB-AGAR™, Salmonella Shigella LAB-AGAR™, BGA LAB-AGAR™ acc. to ISO 6579, Chromogenic Candida LAB-AGARTM, Chromogenic KPC Mod. LAB-AGAR™, Chromogenic ESBL Mod. LAB-AGAR™, Chromogenic Strepto B LAB-AGAR™, Chromogenic MRSA LAB-AGAR™, Chromogenic S. aureus Modified LAB-AGAR™, Yersinia CIN LAB-AGAR™, Palcam Listeria LAB-AGAR™, CHROMagar™ Salmonella PLUS, Chromogenic VRE LAB-AGAR™","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Selektivita","parameters_cs":[{"name":"Selektivita","range":null}],"search_cs":"Selektivně-diferenciační agarová živná půda používaná k izolaci a identifikaci mikroorganismů, XLD LAB-AGAR™, Salmonella Shigella LAB-AGAR™, BGA LAB-AGAR™ acc. to ISO 6579, Chromogenic Candida LAB-AGARTM, Chromogenic KPC Mod. LAB-AGAR™, Chromogenic ESBL Mod. LAB-AGAR™, Chromogenic Strepto B LAB-AGAR™, Chromogenic MRSA LAB-AGAR™, Chromogenic S. aureus Modified LAB-AGAR™, Yersinia CIN LAB-AGAR™, Palcam Listeria LAB-AGAR™, CHROMagar™ Salmonella PLUS, Chromogenic VRE LAB-AGAR™ Selektivita Kvalitativní metoda, plotnová (křížový roztěr) Laboratoř kontroly kvality Mikrobiologie Kvalitativní metoda, plotnová (křížový roztěr) Selektivita PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 6579","technique_cs":"Kvalitativní metoda, plotnová (křížový roztěr)","techniques_cs":["Kvalitativní metoda, plotnová (křížový roztěr)"],"test_object_cs":"Selektivně-diferenciační agarová živná půda používaná k izolaci a identifikaci mikroorganismů, XLD LAB-AGAR™, Salmonella Shigella LAB-AGAR™, BGA LAB-AGAR™ acc. to ISO 6579, Chromogenic Candida LAB-AGARTM, Chromogenic KPC Mod. LAB-AGAR™, Chromogenic ESBL Mod. LAB-AGAR™, Chromogenic Strepto B LAB-AGAR™, Chromogenic MRSA LAB-AGAR™, Chromogenic S. aureus Modified LAB-AGAR™, Yersinia CIN LAB-AGAR™, Palcam Listeria LAB-AGAR™, CHROMagar™ Salmonella PLUS, Chromogenic VRE LAB-AGAR™"},{"_id":"6a8326f6884ede9a1b2c513a","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka agarowa wybiórczo-różnicująca stosowana do izolacji i identyfikacji drobnoustrojów, Mannitol Salt LAB-AGAR™","methodology":"Żyzność","parameters":[{"name":"Żyzność","range":null}],"technique":"Metoda ilościowa, posiew powierzchniowy","techniques":["Metoda ilościowa, posiew powierzchniowy"],"computed":[],"activity":"Żyzność\nMetoda ilościowa, posiew powierzchniowy","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka agarowa wybiórczo-różnicująca stosowana do izolacji i identyfikacji drobnoustrojów, Mannitol Salt LAB-AGAR™ Żyzność\nMetoda ilościowa, posiew powierzchniowy PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 Pozywka agarowa wybiorczo-roznicujaca stosowana do izolacji i identyfikacji drobnoustrojow, Mannitol Salt LAB-AGAR™ Zyznosc\nMetoda ilosciowa, posiew powierzchniowy PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","categories":["construction","microbiology"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fertility","parameters_en":[{"name":"Fertility","range":null}],"search_en":"Selective-differential agar medium used for the isolation and identification of microorganisms, Mannitol Salt LAB-AGAR™ Fertility Quantitative method, spread plate Microbiology Quality Control Laboratory Quantitative method, spread plate Fertility PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_en":"Quantitative method, spread plate","methodology_zh":"肥力","parameters_zh":[{"name":"肥力","range":null}],"search_zh":"用于微生物分离和鉴定的选择性鉴别琼脂培养基，Mannitol Salt LAB-AGAR™ 肥力 定量法，表面涂布 质量控制实验室 微生物 定量法，表面涂布 肥力 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_zh":"定量法，表面涂布","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Quantitative method, spread plate"],"test_object_en":"Selective-differential agar medium used for the isolation and identification of microorganisms, Mannitol Salt LAB-AGAR™","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Bodenfruchtbarkeit","parameters_de":[{"name":"Bodenfruchtbarkeit","range":null}],"search_de":"Selektiv-differenzierender Agarnährboden zur Isolierung und Identifizierung von Mikroorganismen, Mannitol Salt LAB-AGAR™ Bodenfruchtbarkeit Quantitatives Verfahren, Oberflächenverfahren Qualitätskontrolllabor Mikrobiologie Quantitatives Verfahren, Oberflächenverfahren Bodenfruchtbarkeit PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_de":"Quantitatives Verfahren, Oberflächenverfahren","techniques_de":["Quantitatives Verfahren, Oberflächenverfahren"],"test_object_de":"Selektiv-differenzierender Agarnährboden zur Isolierung und Identifizierung von Mikroorganismen, Mannitol Salt LAB-AGAR™","lab_section_zh":"质量控制实验室 微生物","techniques_zh":["定量法，表面涂布"],"test_object_zh":"用于微生物分离和鉴定的选择性鉴别琼脂培养基，Mannitol Salt LAB-AGAR™","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Úrodnost","parameters_cs":[{"name":"Úrodnost","range":null}],"search_cs":"Selektivně-diferenciační agarová živná půda používaná k izolaci a identifikaci mikroorganismů, Mannitol Salt LAB-AGAR™ Úrodnost Kvantitativní metoda, roztěr na povrch Laboratoř kontroly kvality Mikrobiologie Kvantitativní metoda, roztěr na povrch Úrodnost PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_cs":"Kvantitativní metoda, roztěr na povrch","techniques_cs":["Kvantitativní metoda, roztěr na povrch"],"test_object_cs":"Selektivně-diferenciační agarová živná půda používaná k izolaci a identifikaci mikroorganismů, Mannitol Salt LAB-AGAR™"},{"_id":"6a8326f6884ede9a1b2c513b","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka agarowa wybiórczo-różnicująca stosowana do izolacji i identyfikacji drobnoustrojów, Mannitol Salt LAB-AGAR™","methodology":"Specyficzność","parameters":[{"name":"Specyficzność","range":null}],"technique":"Metoda jakościowa płytkowa (posiew rysowy, redukcyjny)","techniques":["Metoda jakościowa płytkowa (posiew rysowy, redukcyjny)"],"computed":[],"activity":"Specyficzność\nMetoda jakościowa płytkowa (posiew rysowy, redukcyjny)","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka agarowa wybiórczo-różnicująca stosowana do izolacji i identyfikacji drobnoustrojów, Mannitol Salt LAB-AGAR™ Specyficzność\nMetoda jakościowa płytkowa (posiew rysowy, redukcyjny) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 Pozywka agarowa wybiorczo-roznicujaca stosowana do izolacji i identyfikacji drobnoustrojow, Mannitol Salt LAB-AGAR™ Specyficznosc\nMetoda jakosciowa plytkowa (posiew rysowy, redukcyjny) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","categories":["construction","microbiology"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specificity","parameters_en":[{"name":"Specificity","range":null}],"search_en":"Selective-differential agar medium used for the isolation and identification of microorganisms, Mannitol Salt LAB-AGAR™ Specificity Qualitative plate method (streak plate, reductive streak) Microbiology Quality Control Laboratory Qualitative plate method (streak plate, reductive streak) Specificity PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_en":"Qualitative plate method (streak plate, reductive streak)","methodology_zh":"特异性","parameters_zh":[{"name":"特异性","range":null}],"search_zh":"用于微生物分离和鉴定的选择性鉴别琼脂培养基，Mannitol Salt LAB-AGAR™ 特异性 定性平板法（划线、稀释接种） 质量控制实验室 微生物 定性平板法（划线、稀释接种） 特异性 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_zh":"定性平板法（划线、稀释接种）","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Qualitative plate method (streak plate, reductive streak)"],"test_object_en":"Selective-differential agar medium used for the isolation and identification of microorganisms, Mannitol Salt LAB-AGAR™","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Spezifität","parameters_de":[{"name":"Spezifität","range":null}],"search_de":"Selektiv-differenzierender Agarnährboden zur Isolierung und Identifizierung von Mikroorganismen, Mannitol Salt LAB-AGAR™ Spezifität Qualitatives Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren) Qualitätskontrolllabor Mikrobiologie Qualitatives Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren) Spezifität PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_de":"Qualitatives Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren)","techniques_de":["Qualitatives Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren)"],"test_object_de":"Selektiv-differenzierender Agarnährboden zur Isolierung und Identifizierung von Mikroorganismen, Mannitol Salt LAB-AGAR™","lab_section_zh":"质量控制实验室 微生物","techniques_zh":["定性平板法（划线、稀释接种）"],"test_object_zh":"用于微生物分离和鉴定的选择性鉴别琼脂培养基，Mannitol Salt LAB-AGAR™","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Specificita","parameters_cs":[{"name":"Specificita","range":null}],"search_cs":"Selektivně-diferenciační agarová živná půda používaná k izolaci a identifikaci mikroorganismů, Mannitol Salt LAB-AGAR™ Specificita Kvalitativní plotnová metoda (křížový roztěr, redukční) Laboratoř kontroly kvality Mikrobiologie Kvalitativní plotnová metoda (křížový roztěr, redukční) Specificita PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_cs":"Kvalitativní plotnová metoda (křížový roztěr, redukční)","techniques_cs":["Kvalitativní plotnová metoda (křížový roztěr, redukční)"],"test_object_cs":"Selektivně-diferenciační agarová živná půda používaná k izolaci a identifikaci mikroorganismů, Mannitol Salt LAB-AGAR™"},{"_id":"6a8326f6884ede9a1b2c513c","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka agarowa wybiórczo-różnicująca stosowana do izolacji i identyfikacji drobnoustrojów, Mannitol Salt LAB-AGAR™","methodology":"Selektywność","parameters":[{"name":"Selektywność","range":null}],"technique":"Metoda jakościowa płytkowa (posiew rysowy)","techniques":["Metoda jakościowa płytkowa (posiew rysowy)"],"computed":[],"activity":"Selektywność\nMetoda jakościowa płytkowa (posiew rysowy)","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka agarowa wybiórczo-różnicująca stosowana do izolacji i identyfikacji drobnoustrojów, Mannitol Salt LAB-AGAR™ Selektywność\nMetoda jakościowa płytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 Pozywka agarowa wybiorczo-roznicujaca stosowana do izolacji i identyfikacji drobnoustrojow, Mannitol Salt LAB-AGAR™ Selektywnosc\nMetoda jakosciowa plytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","categories":["construction","microbiology"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Selectivity","parameters_en":[{"name":"Selectivity","range":null}],"search_en":"Selective-differential agar medium used for the isolation and identification of microorganisms, Mannitol Salt LAB-AGAR™ Selectivity Qualitative plate method (streak plate) Microbiology Quality Control Laboratory Qualitative plate method (streak plate) Selectivity PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_en":"Qualitative plate method (streak plate)","methodology_zh":"选择性","parameters_zh":[{"name":"选择性","range":null}],"search_zh":"用于微生物分离和鉴定的选择性鉴别琼脂培养基，Mannitol Salt LAB-AGAR™ 选择性 定性平板法（划线接种） 质量控制实验室 微生物 定性平板法（划线接种） 选择性 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_zh":"定性平板法（划线接种）","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Qualitative plate method (streak plate)"],"test_object_en":"Selective-differential agar medium used for the isolation and identification of microorganisms, Mannitol Salt LAB-AGAR™","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Selektivität","parameters_de":[{"name":"Selektivität","range":null}],"search_de":"Selektiv-differenzierender Agarnährboden zur Isolierung und Identifizierung von Mikroorganismen, Mannitol Salt LAB-AGAR™ Selektivität Qualitatives Plattenverfahren (Ausstrichverfahren) Qualitätskontrolllabor Mikrobiologie Qualitatives Plattenverfahren (Ausstrichverfahren) Selektivität PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_de":"Qualitatives Plattenverfahren (Ausstrichverfahren)","techniques_de":["Qualitatives Plattenverfahren (Ausstrichverfahren)"],"test_object_de":"Selektiv-differenzierender Agarnährboden zur Isolierung und Identifizierung von Mikroorganismen, Mannitol Salt LAB-AGAR™","lab_section_zh":"质量控制实验室 微生物","techniques_zh":["定性平板法（划线接种）"],"test_object_zh":"用于微生物分离和鉴定的选择性鉴别琼脂培养基，Mannitol Salt LAB-AGAR™","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Selektivita","parameters_cs":[{"name":"Selektivita","range":null}],"search_cs":"Selektivně-diferenciační agarová živná půda používaná k izolaci a identifikaci mikroorganismů, Mannitol Salt LAB-AGAR™ Selektivita Kvalitativní plotnová metoda (křížový roztěr) Laboratoř kontroly kvality Mikrobiologie Kvalitativní plotnová metoda (křížový roztěr) Selektivita PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_cs":"Kvalitativní plotnová metoda (křížový roztěr)","techniques_cs":["Kvalitativní plotnová metoda (křížový roztěr)"],"test_object_cs":"Selektivně-diferenciační agarová živná půda používaná k izolaci a identifikaci mikroorganismů, Mannitol Salt LAB-AGAR™"},{"_id":"6a8326f6884ede9a1b2c513d","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka agarowa selektywna stosowana do oznaczania liczby drobnoustrojów, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™","methodology":"Żyzność","parameters":[{"name":"Żyzność","range":null}],"technique":"Metoda ilościowa, posiew powierzchniowy","techniques":["Metoda ilościowa, posiew powierzchniowy"],"computed":[],"activity":"Żyzność\nMetoda ilościowa, posiew powierzchniowy","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 11290","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10","ISO 11290"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka agarowa selektywna stosowana do oznaczania liczby drobnoustrojów, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™ Żyzność\nMetoda ilościowa, posiew powierzchniowy PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 11290 Pozywka agarowa selektywna stosowana do oznaczania liczby drobnoustrojow, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™ Zyznosc\nMetoda ilosciowa, posiew powierzchniowy PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 11290","categories":["microbiology"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fertility","parameters_en":[{"name":"Fertility","range":null}],"search_en":"Selective agar medium used for the enumeration of microorganisms, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™ Fertility Quantitative method, spread plate Microbiology Quality Control Laboratory Quantitative method, spread plate Fertility PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 11290","technique_en":"Quantitative method, spread plate","methodology_zh":"肥力","parameters_zh":[{"name":"肥力","range":null}],"search_zh":"用于微生物计数的选择性琼脂培养基，Chromogenic TBX LAB-AGARTM、Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290、Baird Parker LAB -AGAR™、Bacillus cereus LAB -AGAR™ 肥力 定量法，表面涂布 质量控制实验室 微生物 定量法，表面涂布 肥力 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 11290","technique_zh":"定量法，表面涂布","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Quantitative method, spread plate"],"test_object_en":"Selective agar medium used for the enumeration of microorganisms, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Bodenfruchtbarkeit","parameters_de":[{"name":"Bodenfruchtbarkeit","range":null}],"search_de":"Selektiver Agarnährboden zur Bestimmung der Keimzahl, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™ Bodenfruchtbarkeit Quantitatives Verfahren, Oberflächenverfahren Qualitätskontrolllabor Mikrobiologie Quantitatives Verfahren, Oberflächenverfahren Bodenfruchtbarkeit PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 11290","technique_de":"Quantitatives Verfahren, Oberflächenverfahren","techniques_de":["Quantitatives Verfahren, Oberflächenverfahren"],"test_object_de":"Selektiver Agarnährboden zur Bestimmung der Keimzahl, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™","lab_section_zh":"质量控制实验室 微生物","techniques_zh":["定量法，表面涂布"],"test_object_zh":"用于微生物计数的选择性琼脂培养基，Chromogenic TBX LAB-AGARTM、Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290、Baird Parker LAB -AGAR™、Bacillus cereus LAB -AGAR™","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Úrodnost","parameters_cs":[{"name":"Úrodnost","range":null}],"search_cs":"Selektivní agarová živná půda používaná ke stanovení počtu mikroorganismů, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™ Úrodnost Kvantitativní metoda, roztěr na povrch Laboratoř kontroly kvality Mikrobiologie Kvantitativní metoda, roztěr na povrch Úrodnost PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 11290","technique_cs":"Kvantitativní metoda, roztěr na povrch","techniques_cs":["Kvantitativní metoda, roztěr na povrch"],"test_object_cs":"Selektivní agarová živná půda používaná ke stanovení počtu mikroorganismů, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™"},{"_id":"6a8326f6884ede9a1b2c513e","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka agarowa selektywna stosowana do oznaczania liczby drobnoustrojów, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™","methodology":"Specyficzność","parameters":[{"name":"Specyficzność","range":null}],"technique":"Metoda jakościowa płytkowa (posiew rysowy, redukcyjny)","techniques":["Metoda jakościowa płytkowa (posiew rysowy, redukcyjny)"],"computed":[],"activity":"Specyficzność\nMetoda jakościowa płytkowa (posiew rysowy, redukcyjny)","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 11290","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10","ISO 11290"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka agarowa selektywna stosowana do oznaczania liczby drobnoustrojów, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™ Specyficzność\nMetoda jakościowa płytkowa (posiew rysowy, redukcyjny) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 11290 Pozywka agarowa selektywna stosowana do oznaczania liczby drobnoustrojow, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™ Specyficznosc\nMetoda jakosciowa plytkowa (posiew rysowy, redukcyjny) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 11290","categories":["microbiology"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specificity","parameters_en":[{"name":"Specificity","range":null}],"search_en":"Selective agar medium used for the enumeration of microorganisms, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™ Specificity Qualitative plate method (streak plate, reductive streak) Microbiology Quality Control Laboratory Qualitative plate method (streak plate, reductive streak) Specificity PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 11290","technique_en":"Qualitative plate method (streak plate, reductive streak)","methodology_zh":"特异性","parameters_zh":[{"name":"特异性","range":null}],"search_zh":"用于微生物计数的选择性琼脂培养基，Chromogenic TBX LAB-AGARTM、Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290、Baird Parker LAB -AGAR™、Bacillus cereus LAB -AGAR™ 特异性 定性平板法（划线、稀释接种） 质量控制实验室 微生物 定性平板法（划线、稀释接种） 特异性 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 11290","technique_zh":"定性平板法（划线、稀释接种）","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Qualitative plate method (streak plate, reductive streak)"],"test_object_en":"Selective agar medium used for the enumeration of microorganisms, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Spezifität","parameters_de":[{"name":"Spezifität","range":null}],"search_de":"Selektiver Agarnährboden zur Bestimmung der Keimzahl, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™ Spezifität Qualitatives Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren) Qualitätskontrolllabor Mikrobiologie Qualitatives Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren) Spezifität PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 11290","technique_de":"Qualitatives Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren)","techniques_de":["Qualitatives Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren)"],"test_object_de":"Selektiver Agarnährboden zur Bestimmung der Keimzahl, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™","lab_section_zh":"质量控制实验室 微生物","techniques_zh":["定性平板法（划线、稀释接种）"],"test_object_zh":"用于微生物计数的选择性琼脂培养基，Chromogenic TBX LAB-AGARTM、Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290、Baird Parker LAB -AGAR™、Bacillus cereus LAB -AGAR™","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Specificita","parameters_cs":[{"name":"Specificita","range":null}],"search_cs":"Selektivní agarová živná půda používaná ke stanovení počtu mikroorganismů, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™ Specificita Kvalitativní plotnová metoda (křížový roztěr, redukční) Laboratoř kontroly kvality Mikrobiologie Kvalitativní plotnová metoda (křížový roztěr, redukční) Specificita PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 11290","technique_cs":"Kvalitativní plotnová metoda (křížový roztěr, redukční)","techniques_cs":["Kvalitativní plotnová metoda (křížový roztěr, redukční)"],"test_object_cs":"Selektivní agarová živná půda používaná ke stanovení počtu mikroorganismů, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™"},{"_id":"6a8326f6884ede9a1b2c513f","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka agarowa selektywna stosowana do oznaczania liczby drobnoustrojów, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™","methodology":"Selektywność","parameters":[{"name":"Selektywność","range":null}],"technique":"Metoda jakościowa płytkowa (posiew rysowy)","techniques":["Metoda jakościowa płytkowa (posiew rysowy)"],"computed":[],"activity":"Selektywność\nMetoda jakościowa płytkowa (posiew rysowy)","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 11290","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10","ISO 11290"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka agarowa selektywna stosowana do oznaczania liczby drobnoustrojów, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™ Selektywność\nMetoda jakościowa płytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 11290 Pozywka agarowa selektywna stosowana do oznaczania liczby drobnoustrojow, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™ Selektywnosc\nMetoda jakosciowa plytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 11290","categories":["microbiology"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Selectivity","parameters_en":[{"name":"Selectivity","range":null}],"search_en":"Selective agar medium used for the enumeration of microorganisms, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™ Selectivity Qualitative plate method (streak plate) Microbiology Quality Control Laboratory Qualitative plate method (streak plate) Selectivity PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 11290","technique_en":"Qualitative plate method (streak plate)","methodology_zh":"选择性","parameters_zh":[{"name":"选择性","range":null}],"search_zh":"用于微生物计数的选择性琼脂培养基，Chromogenic TBX LAB-AGARTM、Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290、Baird Parker LAB -AGAR™、Bacillus cereus LAB -AGAR™ 选择性 定性平板法（划线接种） 质量控制实验室 微生物 定性平板法（划线接种） 选择性 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 11290","technique_zh":"定性平板法（划线接种）","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Qualitative plate method (streak plate)"],"test_object_en":"Selective agar medium used for the enumeration of microorganisms, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Selektivität","parameters_de":[{"name":"Selektivität","range":null}],"search_de":"Selektiver Agarnährboden zur Bestimmung der Keimzahl, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™ Selektivität Qualitatives Plattenverfahren (Ausstrichverfahren) Qualitätskontrolllabor Mikrobiologie Qualitatives Plattenverfahren (Ausstrichverfahren) Selektivität PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 11290","technique_de":"Qualitatives Plattenverfahren (Ausstrichverfahren)","techniques_de":["Qualitatives Plattenverfahren (Ausstrichverfahren)"],"test_object_de":"Selektiver Agarnährboden zur Bestimmung der Keimzahl, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™","lab_section_zh":"质量控制实验室 微生物","techniques_zh":["定性平板法（划线接种）"],"test_object_zh":"用于微生物计数的选择性琼脂培养基，Chromogenic TBX LAB-AGARTM、Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290、Baird Parker LAB -AGAR™、Bacillus cereus LAB -AGAR™","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Selektivita","parameters_cs":[{"name":"Selektivita","range":null}],"search_cs":"Selektivní agarová živná půda používaná ke stanovení počtu mikroorganismů, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™ Selektivita Kvalitativní plotnová metoda (křížový roztěr) Laboratoř kontroly kvality Mikrobiologie Kvalitativní plotnová metoda (křížový roztěr) Selektivita PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 11290","technique_cs":"Kvalitativní plotnová metoda (křížový roztěr)","techniques_cs":["Kvalitativní plotnová metoda (křížový roztěr)"],"test_object_cs":"Selektivní agarová živná půda používaná ke stanovení počtu mikroorganismů, Chromogenic TBX LAB-AGARTM, Chromogenic Listeria LAB-AGAR™ acc. to ISO 11290, Baird Parker LAB -AGAR™, Bacillus cereus LAB -AGAR™"},{"_id":"6a8326f6884ede9a1b2c5140","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka agarowa selektywna stosowana do oznaczania liczby drobnoustrojów, Cetrimide LAB-AGAR™, CCDA LAB -AGAR™, MacConkey LAB-AGAR™, DRBC LAB -AGAR™","methodology":"Żyzność","parameters":[{"name":"Żyzność","range":null}],"technique":"Metoda ilościowa, posiew powierzchniowy","techniques":["Metoda ilościowa, posiew powierzchniowy"],"computed":[],"activity":"Żyzność\nMetoda ilościowa, posiew powierzchniowy","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka agarowa selektywna stosowana do oznaczania liczby drobnoustrojów, Cetrimide LAB-AGAR™, CCDA LAB -AGAR™, MacConkey LAB-AGAR™, DRBC LAB -AGAR™ Żyzność\nMetoda ilościowa, posiew powierzchniowy PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 Pozywka agarowa selektywna stosowana do oznaczania liczby drobnoustrojow, Cetrimide LAB-AGAR™, CCDA LAB -AGAR™, MacConkey LAB-AGAR™, DRBC LAB -AGAR™ Zyznosc\nMetoda ilosciowa, posiew powierzchniowy PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","categories":["microbiology"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fertility","parameters_en":[{"name":"Fertility","range":null}],"search_en":"Selective agar medium used for the enumeration of microorganisms, Cetrimide LAB-AGAR™, CCDA LAB -AGAR™, MacConkey LAB-AGAR™, DRBC LAB -AGAR™ Fertility Quantitative method, spread plate Microbiology Quality Control Laboratory Quantitative method, spread plate Fertility PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_en":"Quantitative method, spread plate","methodology_zh":"肥力","parameters_zh":[{"name":"肥力","range":null}],"search_zh":"用于微生物计数的选择性琼脂培养基，Cetrimide LAB-AGAR™、CCDA LAB -AGAR™、MacConkey LAB-AGAR™、DRBC LAB -AGAR™ 肥力 定量法，表面涂布 质量控制实验室 微生物 定量法，表面涂布 肥力 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_zh":"定量法，表面涂布","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Quantitative method, spread plate"],"test_object_en":"Selective agar medium used for the enumeration of microorganisms, Cetrimide LAB-AGAR™, CCDA LAB -AGAR™, MacConkey LAB-AGAR™, DRBC LAB -AGAR™","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Bodenfruchtbarkeit","parameters_de":[{"name":"Bodenfruchtbarkeit","range":null}],"search_de":"Selektiver Agarnährboden zur Bestimmung der Keimzahl, Cetrimide LAB-AGAR™, CCDA LAB -AGAR™, MacConkey LAB-AGAR™, DRBC LAB -AGAR™ Bodenfruchtbarkeit Quantitatives Verfahren, Oberflächenverfahren Qualitätskontrolllabor Mikrobiologie Quantitatives Verfahren, Oberflächenverfahren Bodenfruchtbarkeit PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_de":"Quantitatives Verfahren, Oberflächenverfahren","techniques_de":["Quantitatives Verfahren, Oberflächenverfahren"],"test_object_de":"Selektiver Agarnährboden zur Bestimmung der Keimzahl, Cetrimide LAB-AGAR™, CCDA LAB -AGAR™, MacConkey LAB-AGAR™, DRBC LAB -AGAR™","lab_section_zh":"质量控制实验室 微生物","techniques_zh":["定量法，表面涂布"],"test_object_zh":"用于微生物计数的选择性琼脂培养基，Cetrimide LAB-AGAR™、CCDA LAB -AGAR™、MacConkey LAB-AGAR™、DRBC LAB -AGAR™","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Úrodnost","parameters_cs":[{"name":"Úrodnost","range":null}],"search_cs":"Selektivní agarová živná půda používaná ke stanovení počtu mikroorganismů, Cetrimide LAB-AGAR™, CCDA LAB -AGAR™, MacConkey LAB-AGAR™, DRBC LAB -AGAR™ Úrodnost Kvantitativní metoda, roztěr na povrch Laboratoř kontroly kvality Mikrobiologie Kvantitativní metoda, roztěr na povrch Úrodnost PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_cs":"Kvantitativní metoda, roztěr na povrch","techniques_cs":["Kvantitativní metoda, roztěr na povrch"],"test_object_cs":"Selektivní agarová živná půda používaná ke stanovení počtu mikroorganismů, Cetrimide LAB-AGAR™, CCDA LAB -AGAR™, MacConkey LAB-AGAR™, DRBC LAB -AGAR™"},{"_id":"6a8326f6884ede9a1b2c5141","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka agarowa selektywna stosowana do oznaczania liczby drobnoustrojów, Cetrimide LAB-AGAR™, CCDA LAB -AGAR™, MacConkey LAB-AGAR™, DRBC LAB -AGAR™","methodology":"Selektywność","parameters":[{"name":"Selektywność","range":null}],"technique":"Metoda jakościowa płytkowa (posiew rysowy)","techniques":["Metoda jakościowa płytkowa (posiew rysowy)"],"computed":[],"activity":"Selektywność\nMetoda jakościowa płytkowa (posiew rysowy)","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka agarowa selektywna stosowana do oznaczania liczby drobnoustrojów, Cetrimide LAB-AGAR™, CCDA LAB -AGAR™, MacConkey LAB-AGAR™, DRBC LAB -AGAR™ Selektywność\nMetoda jakościowa płytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 Pozywka agarowa selektywna stosowana do oznaczania liczby drobnoustrojow, Cetrimide LAB-AGAR™, CCDA LAB -AGAR™, MacConkey LAB-AGAR™, DRBC LAB -AGAR™ Selektywnosc\nMetoda jakosciowa plytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","categories":["microbiology"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Selectivity","parameters_en":[{"name":"Selectivity","range":null}],"search_en":"Selective agar medium used for the enumeration of microorganisms, Cetrimide LAB-AGAR™, CCDA LAB -AGAR™, MacConkey LAB-AGAR™, DRBC LAB -AGAR™ Selectivity Qualitative plate method (streak plate) Microbiology Quality Control Laboratory Qualitative plate method (streak plate) Selectivity PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_en":"Qualitative plate method (streak plate)","methodology_zh":"选择性","parameters_zh":[{"name":"选择性","range":null}],"search_zh":"用于微生物计数的选择性琼脂培养基，Cetrimide LAB-AGAR™、CCDA LAB -AGAR™、MacConkey LAB-AGAR™、DRBC LAB -AGAR™ 选择性 定性平板法（划线接种） 质量控制实验室 微生物 定性平板法（划线接种） 选择性 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_zh":"定性平板法（划线接种）","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Qualitative plate method (streak plate)"],"test_object_en":"Selective agar medium used for the enumeration of microorganisms, Cetrimide LAB-AGAR™, CCDA LAB -AGAR™, MacConkey LAB-AGAR™, DRBC LAB -AGAR™","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Selektivität","parameters_de":[{"name":"Selektivität","range":null}],"search_de":"Selektiver Agarnährboden zur Bestimmung der Keimzahl, Cetrimide LAB-AGAR™, CCDA LAB -AGAR™, MacConkey LAB-AGAR™, DRBC LAB -AGAR™ Selektivität Qualitatives Plattenverfahren (Ausstrichverfahren) Qualitätskontrolllabor Mikrobiologie Qualitatives Plattenverfahren (Ausstrichverfahren) Selektivität PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_de":"Qualitatives Plattenverfahren (Ausstrichverfahren)","techniques_de":["Qualitatives Plattenverfahren (Ausstrichverfahren)"],"test_object_de":"Selektiver Agarnährboden zur Bestimmung der Keimzahl, Cetrimide LAB-AGAR™, CCDA LAB -AGAR™, MacConkey LAB-AGAR™, DRBC LAB -AGAR™","lab_section_zh":"质量控制实验室 微生物","techniques_zh":["定性平板法（划线接种）"],"test_object_zh":"用于微生物计数的选择性琼脂培养基，Cetrimide LAB-AGAR™、CCDA LAB -AGAR™、MacConkey LAB-AGAR™、DRBC LAB -AGAR™","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Selektivita","parameters_cs":[{"name":"Selektivita","range":null}],"search_cs":"Selektivní agarová živná půda používaná ke stanovení počtu mikroorganismů, Cetrimide LAB-AGAR™, CCDA LAB -AGAR™, MacConkey LAB-AGAR™, DRBC LAB -AGAR™ Selektivita Kvalitativní plotnová metoda (křížový roztěr) Laboratoř kontroly kvality Mikrobiologie Kvalitativní plotnová metoda (křížový roztěr) Selektivita PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_cs":"Kvalitativní plotnová metoda (křížový roztěr)","techniques_cs":["Kvalitativní plotnová metoda (křížový roztěr)"],"test_object_cs":"Selektivní agarová živná půda používaná ke stanovení počtu mikroorganismů, Cetrimide LAB-AGAR™, CCDA LAB -AGAR™, MacConkey LAB-AGAR™, DRBC LAB -AGAR™"},{"_id":"6a8326f6884ede9a1b2c5142","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka agarowa selektywna stosowana do izolacji drobnoustrojów, Sabouraud Dextrose with Chloramphenicol and Gentamicin LAB-AGAR™","methodology":"Żyzność","parameters":[{"name":"Żyzność","range":null}],"technique":"Metoda jakościowa, płytkowa (posiew rysowy, redukcyjny)","techniques":["Metoda jakościowa, płytkowa (posiew rysowy, redukcyjny)"],"computed":[],"activity":"Żyzność\nMetoda jakościowa, płytkowa (posiew rysowy, redukcyjny)","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka agarowa selektywna stosowana do izolacji drobnoustrojów, Sabouraud Dextrose with Chloramphenicol and Gentamicin LAB-AGAR™ Żyzność\nMetoda jakościowa, płytkowa (posiew rysowy, redukcyjny) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 Pozywka agarowa selektywna stosowana do izolacji drobnoustrojow, Sabouraud Dextrose with Chloramphenicol and Gentamicin LAB-AGAR™ Zyznosc\nMetoda jakosciowa, plytkowa (posiew rysowy, redukcyjny) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","categories":["construction","microbiology"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fertility","parameters_en":[{"name":"Fertility","range":null}],"search_en":"Selective agar medium used for the isolation of microorganisms, Sabouraud Dextrose with Chloramphenicol and Gentamicin LAB-AGAR™ Fertility Qualitative plate method (streak plate, reductive streak) Microbiology Quality Control Laboratory Qualitative plate method (streak plate, reductive streak) Fertility PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_en":"Qualitative plate method (streak plate, reductive streak)","methodology_zh":"肥力","parameters_zh":[{"name":"肥力","range":null}],"search_zh":"用于微生物分离的选择性琼脂培养基，Sabouraud Dextrose with Chloramphenicol and Gentamicin LAB-AGAR™ 肥力 定性平板法（划线、稀释接种） 质量控制实验室 微生物 定性平板法（划线、稀释接种） 肥力 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_zh":"定性平板法（划线、稀释接种）","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Qualitative plate method (streak plate, reductive streak)"],"test_object_en":"Selective agar medium used for the isolation of microorganisms, Sabouraud Dextrose with Chloramphenicol and Gentamicin LAB-AGAR™","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Bodenfruchtbarkeit","parameters_de":[{"name":"Bodenfruchtbarkeit","range":null}],"search_de":"Selektiver Agarnährboden zur Isolierung von Mikroorganismen, Sabouraud Dextrose with Chloramphenicol and Gentamicin LAB-AGAR™ Bodenfruchtbarkeit Qualitatives Verfahren, Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren) Qualitätskontrolllabor Mikrobiologie Qualitatives Verfahren, Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren) Bodenfruchtbarkeit PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_de":"Qualitatives Verfahren, Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren)","techniques_de":["Qualitatives Verfahren, Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren)"],"test_object_de":"Selektiver Agarnährboden zur Isolierung von Mikroorganismen, Sabouraud Dextrose with Chloramphenicol and Gentamicin LAB-AGAR™","lab_section_zh":"质量控制实验室 微生物","techniques_zh":["定性平板法（划线、稀释接种）"],"test_object_zh":"用于微生物分离的选择性琼脂培养基，Sabouraud Dextrose with Chloramphenicol and Gentamicin LAB-AGAR™","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Úrodnost","parameters_cs":[{"name":"Úrodnost","range":null}],"search_cs":"Selektivní agarová živná půda používaná k izolaci mikroorganismů, Sabouraud Dextrose with Chloramphenicol and Gentamicin LAB-AGAR™ Úrodnost Kvalitativní metoda, plotnová (křížový roztěr, redukční) Laboratoř kontroly kvality Mikrobiologie Kvalitativní metoda, plotnová (křížový roztěr, redukční) Úrodnost PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_cs":"Kvalitativní metoda, plotnová (křížový roztěr, redukční)","techniques_cs":["Kvalitativní metoda, plotnová (křížový roztěr, redukční)"],"test_object_cs":"Selektivní agarová živná půda používaná k izolaci mikroorganismů, Sabouraud Dextrose with Chloramphenicol and Gentamicin LAB-AGAR™"},{"_id":"6a8326f6884ede9a1b2c5143","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka agarowa selektywna stosowana do izolacji drobnoustrojów, Sabouraud Dextrose with Chloramphenicol and Gentamicin LAB-AGAR™","methodology":"Selektywność","parameters":[{"name":"Selektywność","range":null}],"technique":"Metoda jakościowa, płytkowa (posiew rysowy)","techniques":["Metoda jakościowa, płytkowa (posiew rysowy)"],"computed":[],"activity":"Selektywność\nMetoda jakościowa, płytkowa (posiew rysowy)","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka agarowa selektywna stosowana do izolacji drobnoustrojów, Sabouraud Dextrose with Chloramphenicol and Gentamicin LAB-AGAR™ Selektywność\nMetoda jakościowa, płytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 Pozywka agarowa selektywna stosowana do izolacji drobnoustrojow, Sabouraud Dextrose with Chloramphenicol and Gentamicin LAB-AGAR™ Selektywnosc\nMetoda jakosciowa, plytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","categories":["construction","microbiology"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Selectivity","parameters_en":[{"name":"Selectivity","range":null}],"search_en":"Selective agar medium used for the isolation of microorganisms, Sabouraud Dextrose with Chloramphenicol and Gentamicin LAB-AGAR™ Selectivity Qualitative plate method (streak plate) Microbiology Quality Control Laboratory Qualitative plate method (streak plate) Selectivity PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_en":"Qualitative plate method (streak plate)","methodology_zh":"选择性","parameters_zh":[{"name":"选择性","range":null}],"search_zh":"用于微生物分离的选择性琼脂培养基，Sabouraud Dextrose with Chloramphenicol and Gentamicin LAB-AGAR™ 选择性 定性平板法（划线接种） 质量控制实验室 微生物 定性平板法（划线接种） 选择性 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_zh":"定性平板法（划线接种）","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Qualitative plate method (streak plate)"],"test_object_en":"Selective agar medium used for the isolation of microorganisms, Sabouraud Dextrose with Chloramphenicol and Gentamicin LAB-AGAR™","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Selektivität","parameters_de":[{"name":"Selektivität","range":null}],"search_de":"Selektiver Agarnährboden zur Isolierung von Mikroorganismen, Sabouraud Dextrose with Chloramphenicol and Gentamicin LAB-AGAR™ Selektivität Qualitatives Verfahren, Plattenverfahren (Ausstrichverfahren) Qualitätskontrolllabor Mikrobiologie Qualitatives Verfahren, Plattenverfahren (Ausstrichverfahren) Selektivität PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_de":"Qualitatives Verfahren, Plattenverfahren (Ausstrichverfahren)","techniques_de":["Qualitatives Verfahren, Plattenverfahren (Ausstrichverfahren)"],"test_object_de":"Selektiver Agarnährboden zur Isolierung von Mikroorganismen, Sabouraud Dextrose with Chloramphenicol and Gentamicin LAB-AGAR™","lab_section_zh":"质量控制实验室 微生物","techniques_zh":["定性平板法（划线接种）"],"test_object_zh":"用于微生物分离的选择性琼脂培养基，Sabouraud Dextrose with Chloramphenicol and Gentamicin LAB-AGAR™","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Selektivita","parameters_cs":[{"name":"Selektivita","range":null}],"search_cs":"Selektivní agarová živná půda používaná k izolaci mikroorganismů, Sabouraud Dextrose with Chloramphenicol and Gentamicin LAB-AGAR™ Selektivita Kvalitativní metoda, plotnová (křížový roztěr) Laboratoř kontroly kvality Mikrobiologie Kvalitativní metoda, plotnová (křížový roztěr) Selektivita PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_cs":"Kvalitativní metoda, plotnová (křížový roztěr)","techniques_cs":["Kvalitativní metoda, plotnová (křížový roztěr)"],"test_object_cs":"Selektivní agarová živná půda používaná k izolaci mikroorganismů, Sabouraud Dextrose with Chloramphenicol and Gentamicin LAB-AGAR™"},{"_id":"6a8326f6884ede9a1b2c5144","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka selektywna agarowa stosowana w metodzie filtracji membranowej, Pseudomonas CN LAB-AGAR™, Legionella GVPC LAB-AGAR™, TSC LAB-AGAR™, Slanetz and Bartley LAB-AGAR™","methodology":"Żyzność","parameters":[{"name":"Żyzność","range":null}],"technique":"Metoda ilościowa, płytkowa (filtracja membranowa)","techniques":["Metoda ilościowa, płytkowa (filtracja membranowa)"],"computed":[],"activity":"Żyzność\nMetoda ilościowa, płytkowa (filtracja membranowa)","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka selektywna agarowa stosowana w metodzie filtracji membranowej, Pseudomonas CN LAB-AGAR™, Legionella GVPC LAB-AGAR™, TSC LAB-AGAR™, Slanetz and Bartley LAB-AGAR™ Żyzność\nMetoda ilościowa, płytkowa (filtracja membranowa) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 Pozywka selektywna agarowa stosowana w metodzie filtracji membranowej, Pseudomonas CN LAB-AGAR™, Legionella GVPC LAB-AGAR™, TSC LAB-AGAR™, Slanetz and Bartley LAB-AGAR™ Zyznosc\nMetoda ilosciowa, plytkowa (filtracja membranowa) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","categories":["microbiology"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fertility","parameters_en":[{"name":"Fertility","range":null}],"search_en":"Selective agar medium used in the membrane filtration method, Pseudomonas CN LAB-AGAR™, Legionella GVPC LAB-AGAR™, TSC LAB-AGAR™, Slanetz and Bartley LAB-AGAR™ Fertility Quantitative plate method (membrane filtration) Microbiology Quality Control Laboratory Quantitative plate method (membrane filtration) Fertility PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_en":"Quantitative plate method (membrane filtration)","methodology_zh":"肥力","parameters_zh":[{"name":"肥力","range":null}],"search_zh":"用于膜过滤法的选择性琼脂培养基，Pseudomonas CN LAB-AGAR™、Legionella GVPC LAB-AGAR™、TSC LAB-AGAR™、Slanetz and Bartley LAB-AGAR™ 肥力 定量平板法（膜过滤） 质量控制实验室 微生物 定量平板法（膜过滤） 肥力 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_zh":"定量平板法（膜过滤）","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Quantitative plate method (membrane filtration)"],"test_object_en":"Selective agar medium used in the membrane filtration method, Pseudomonas CN LAB-AGAR™, Legionella GVPC LAB-AGAR™, TSC LAB-AGAR™, Slanetz and Bartley LAB-AGAR™","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Bodenfruchtbarkeit","parameters_de":[{"name":"Bodenfruchtbarkeit","range":null}],"search_de":"Selektiver Agarnährboden für das Membranfiltrationsverfahren, Pseudomonas CN LAB-AGAR™, Legionella GVPC LAB-AGAR™, TSC LAB-AGAR™, Slanetz and Bartley LAB-AGAR™ Bodenfruchtbarkeit Quantitatives Verfahren, Plattenverfahren (Membranfiltration) Qualitätskontrolllabor Mikrobiologie Quantitatives Verfahren, Plattenverfahren (Membranfiltration) Bodenfruchtbarkeit PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_de":"Quantitatives Verfahren, Plattenverfahren (Membranfiltration)","techniques_de":["Quantitatives Verfahren, Plattenverfahren (Membranfiltration)"],"test_object_de":"Selektiver Agarnährboden für das Membranfiltrationsverfahren, Pseudomonas CN LAB-AGAR™, Legionella GVPC LAB-AGAR™, TSC LAB-AGAR™, Slanetz and Bartley LAB-AGAR™","lab_section_zh":"质量控制实验室 微生物","techniques_zh":["定量平板法（膜过滤）"],"test_object_zh":"用于膜过滤法的选择性琼脂培养基，Pseudomonas CN LAB-AGAR™、Legionella GVPC LAB-AGAR™、TSC LAB-AGAR™、Slanetz and Bartley LAB-AGAR™","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Úrodnost","parameters_cs":[{"name":"Úrodnost","range":null}],"search_cs":"Selektivní agarová živná půda používaná v metodě membránové filtrace, Pseudomonas CN LAB-AGAR™, Legionella GVPC LAB-AGAR™, TSC LAB-AGAR™, Slanetz and Bartley LAB-AGAR™ Úrodnost Kvantitativní metoda, plotnová (membránová filtrace) Laboratoř kontroly kvality Mikrobiologie Kvantitativní metoda, plotnová (membránová filtrace) Úrodnost PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_cs":"Kvantitativní metoda, plotnová (membránová filtrace)","techniques_cs":["Kvantitativní metoda, plotnová (membránová filtrace)"],"test_object_cs":"Selektivní agarová živná půda používaná v metodě membránové filtrace, Pseudomonas CN LAB-AGAR™, Legionella GVPC LAB-AGAR™, TSC LAB-AGAR™, Slanetz and Bartley LAB-AGAR™"},{"_id":"6a8326f6884ede9a1b2c5145","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka selektywna agarowa stosowana w metodzie filtracji membranowej, Pseudomonas CN LAB-AGAR™, Legionella GVPC LAB-AGAR™, TSC LAB-AGAR™, Slanetz and Bartley LAB-AGAR™","methodology":"Selektywność","parameters":[{"name":"Selektywność","range":null}],"technique":"Metoda jakościowa płytkowa (posiew rysowy)","techniques":["Metoda jakościowa płytkowa (posiew rysowy)"],"computed":[],"activity":"Selektywność\nMetoda jakościowa płytkowa (posiew rysowy)","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka selektywna agarowa stosowana w metodzie filtracji membranowej, Pseudomonas CN LAB-AGAR™, Legionella GVPC LAB-AGAR™, TSC LAB-AGAR™, Slanetz and Bartley LAB-AGAR™ Selektywność\nMetoda jakościowa płytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 Pozywka selektywna agarowa stosowana w metodzie filtracji membranowej, Pseudomonas CN LAB-AGAR™, Legionella GVPC LAB-AGAR™, TSC LAB-AGAR™, Slanetz and Bartley LAB-AGAR™ Selektywnosc\nMetoda jakosciowa plytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","categories":["microbiology"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Selectivity","parameters_en":[{"name":"Selectivity","range":null}],"search_en":"Selective agar medium used in the membrane filtration method, Pseudomonas CN LAB-AGAR™, Legionella GVPC LAB-AGAR™, TSC LAB-AGAR™, Slanetz and Bartley LAB-AGAR™ Selectivity Qualitative plate method (streak plate) Microbiology Quality Control Laboratory Qualitative plate method (streak plate) Selectivity PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_en":"Qualitative plate method (streak plate)","methodology_zh":"选择性","parameters_zh":[{"name":"选择性","range":null}],"search_zh":"用于膜过滤法的选择性琼脂培养基，Pseudomonas CN LAB-AGAR™、Legionella GVPC LAB-AGAR™、TSC LAB-AGAR™、Slanetz and Bartley LAB-AGAR™ 选择性 定性平板法（划线接种） 质量控制实验室 微生物 定性平板法（划线接种） 选择性 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_zh":"定性平板法（划线接种）","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Qualitative plate method (streak plate)"],"test_object_en":"Selective agar medium used in the membrane filtration method, Pseudomonas CN LAB-AGAR™, Legionella GVPC LAB-AGAR™, TSC LAB-AGAR™, Slanetz and Bartley LAB-AGAR™","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Selektivität","parameters_de":[{"name":"Selektivität","range":null}],"search_de":"Selektiver Agarnährboden für das Membranfiltrationsverfahren, Pseudomonas CN LAB-AGAR™, Legionella GVPC LAB-AGAR™, TSC LAB-AGAR™, Slanetz and Bartley LAB-AGAR™ Selektivität Qualitatives Plattenverfahren (Ausstrichverfahren) Qualitätskontrolllabor Mikrobiologie Qualitatives Plattenverfahren (Ausstrichverfahren) Selektivität PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_de":"Qualitatives Plattenverfahren (Ausstrichverfahren)","techniques_de":["Qualitatives Plattenverfahren (Ausstrichverfahren)"],"test_object_de":"Selektiver Agarnährboden für das Membranfiltrationsverfahren, Pseudomonas CN LAB-AGAR™, Legionella GVPC LAB-AGAR™, TSC LAB-AGAR™, Slanetz and Bartley LAB-AGAR™","lab_section_zh":"质量控制实验室 微生物","techniques_zh":["定性平板法（划线接种）"],"test_object_zh":"用于膜过滤法的选择性琼脂培养基，Pseudomonas CN LAB-AGAR™、Legionella GVPC LAB-AGAR™、TSC LAB-AGAR™、Slanetz and Bartley LAB-AGAR™","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Selektivita","parameters_cs":[{"name":"Selektivita","range":null}],"search_cs":"Selektivní agarová živná půda používaná v metodě membránové filtrace, Pseudomonas CN LAB-AGAR™, Legionella GVPC LAB-AGAR™, TSC LAB-AGAR™, Slanetz and Bartley LAB-AGAR™ Selektivita Kvalitativní plotnová metoda (křížový roztěr) Laboratoř kontroly kvality Mikrobiologie Kvalitativní plotnová metoda (křížový roztěr) Selektivita PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_cs":"Kvalitativní plotnová metoda (křížový roztěr)","techniques_cs":["Kvalitativní plotnová metoda (křížový roztěr)"],"test_object_cs":"Selektivní agarová živná půda používaná v metodě membránové filtrace, Pseudomonas CN LAB-AGAR™, Legionella GVPC LAB-AGAR™, TSC LAB-AGAR™, Slanetz and Bartley LAB-AGAR™"},{"_id":"6a8326f6884ede9a1b2c5146","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka agarowa nieselektywna stosowana do izolacji drobnoustrojów, Legionella BCYE LAB-AGAR ™","methodology":"Żyzność","parameters":[{"name":"Żyzność","range":null}],"technique":"Metoda ilościowa, płytkowa (filtracja membranowa)","techniques":["Metoda ilościowa, płytkowa (filtracja membranowa)"],"computed":[],"activity":"Żyzność\nMetoda ilościowa, płytkowa (filtracja membranowa)","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka agarowa nieselektywna stosowana do izolacji drobnoustrojów, Legionella BCYE LAB-AGAR ™ Żyzność\nMetoda ilościowa, płytkowa (filtracja membranowa) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 Pozywka agarowa nieselektywna stosowana do izolacji drobnoustrojow, Legionella BCYE LAB-AGAR ™ Zyznosc\nMetoda ilosciowa, plytkowa (filtracja membranowa) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","categories":["microbiology","construction"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fertility","parameters_en":[{"name":"Fertility","range":null}],"search_en":"Non-selective agar medium used for the isolation of microorganisms, Legionella BCYE LAB-AGAR ™ Fertility Quantitative plate method (membrane filtration) Microbiology Quality Control Laboratory Quantitative plate method (membrane filtration) Fertility PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_en":"Quantitative plate method (membrane filtration)","methodology_zh":"肥力","parameters_zh":[{"name":"肥力","range":null}],"search_zh":"用于微生物分离的非选择性琼脂培养基，Legionella BCYE LAB-AGAR ™ 肥力 定量平板法（膜过滤） 质量控制实验室 微生物 定量平板法（膜过滤） 肥力 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_zh":"定量平板法（膜过滤）","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Quantitative plate method (membrane filtration)"],"test_object_en":"Non-selective agar medium used for the isolation of microorganisms, Legionella BCYE LAB-AGAR ™","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Bodenfruchtbarkeit","parameters_de":[{"name":"Bodenfruchtbarkeit","range":null}],"search_de":"Nichtselektiver Agarnährboden zur Isolierung von Mikroorganismen, Legionella BCYE LAB-AGAR ™ Bodenfruchtbarkeit Quantitatives Verfahren, Plattenverfahren (Membranfiltration) Qualitätskontrolllabor Mikrobiologie Quantitatives Verfahren, Plattenverfahren (Membranfiltration) Bodenfruchtbarkeit PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_de":"Quantitatives Verfahren, Plattenverfahren (Membranfiltration)","techniques_de":["Quantitatives Verfahren, Plattenverfahren (Membranfiltration)"],"test_object_de":"Nichtselektiver Agarnährboden zur Isolierung von Mikroorganismen, Legionella BCYE LAB-AGAR ™","lab_section_zh":"质量控制实验室 微生物","techniques_zh":["定量平板法（膜过滤）"],"test_object_zh":"用于微生物分离的非选择性琼脂培养基，Legionella BCYE LAB-AGAR ™","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Úrodnost","parameters_cs":[{"name":"Úrodnost","range":null}],"search_cs":"Neselektivní agarová živná půda používaná k izolaci mikroorganismů, Legionella BCYE LAB-AGAR ™ Úrodnost Kvantitativní metoda, plotnová (membránová filtrace) Laboratoř kontroly kvality Mikrobiologie Kvantitativní metoda, plotnová (membránová filtrace) Úrodnost PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_cs":"Kvantitativní metoda, plotnová (membránová filtrace)","techniques_cs":["Kvantitativní metoda, plotnová (membránová filtrace)"],"test_object_cs":"Neselektivní agarová živná půda používaná k izolaci mikroorganismů, Legionella BCYE LAB-AGAR ™"},{"_id":"6a8326f6884ede9a1b2c5147","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka agarowa nieselektywna stosowana do izolacji drobnoustrojów, Legionella BCYE LAB-AGAR ™","methodology":"Specyficzność","parameters":[{"name":"Specyficzność","range":null}],"technique":"Metoda jakościowa, płytkowa (posiew rysowy, redukcyjny)","techniques":["Metoda jakościowa, płytkowa (posiew rysowy, redukcyjny)"],"computed":[],"activity":"Specyficzność\nMetoda jakościowa, płytkowa (posiew rysowy, redukcyjny)","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka agarowa nieselektywna stosowana do izolacji drobnoustrojów, Legionella BCYE LAB-AGAR ™ Specyficzność\nMetoda jakościowa, płytkowa (posiew rysowy, redukcyjny) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 Pozywka agarowa nieselektywna stosowana do izolacji drobnoustrojow, Legionella BCYE LAB-AGAR ™ Specyficznosc\nMetoda jakosciowa, plytkowa (posiew rysowy, redukcyjny) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","categories":["microbiology","construction"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specificity","parameters_en":[{"name":"Specificity","range":null}],"search_en":"Non-selective agar medium used for the isolation of microorganisms, Legionella BCYE LAB-AGAR ™ Specificity Qualitative plate method (streak plate, reductive streak) Microbiology Quality Control Laboratory Qualitative plate method (streak plate, reductive streak) Specificity PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_en":"Qualitative plate method (streak plate, reductive streak)","methodology_zh":"特异性","parameters_zh":[{"name":"特异性","range":null}],"search_zh":"用于微生物分离的非选择性琼脂培养基，Legionella BCYE LAB-AGAR ™ 特异性 定性平板法（划线、稀释接种） 质量控制实验室 微生物 定性平板法（划线、稀释接种） 特异性 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_zh":"定性平板法（划线、稀释接种）","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Qualitative plate method (streak plate, reductive streak)"],"test_object_en":"Non-selective agar medium used for the isolation of microorganisms, Legionella BCYE LAB-AGAR ™","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Spezifität","parameters_de":[{"name":"Spezifität","range":null}],"search_de":"Nichtselektiver Agarnährboden zur Isolierung von Mikroorganismen, Legionella BCYE LAB-AGAR ™ Spezifität Qualitatives Verfahren, Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren) Qualitätskontrolllabor Mikrobiologie Qualitatives Verfahren, Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren) Spezifität PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_de":"Qualitatives Verfahren, Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren)","techniques_de":["Qualitatives Verfahren, Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren)"],"test_object_de":"Nichtselektiver Agarnährboden zur Isolierung von Mikroorganismen, Legionella BCYE LAB-AGAR ™","lab_section_zh":"质量控制实验室 微生物","techniques_zh":["定性平板法（划线、稀释接种）"],"test_object_zh":"用于微生物分离的非选择性琼脂培养基，Legionella BCYE LAB-AGAR ™","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Specificita","parameters_cs":[{"name":"Specificita","range":null}],"search_cs":"Neselektivní agarová živná půda používaná k izolaci mikroorganismů, Legionella BCYE LAB-AGAR ™ Specificita Kvalitativní metoda, plotnová (křížový roztěr, redukční) Laboratoř kontroly kvality Mikrobiologie Kvalitativní metoda, plotnová (křížový roztěr, redukční) Specificita PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_cs":"Kvalitativní metoda, plotnová (křížový roztěr, redukční)","techniques_cs":["Kvalitativní metoda, plotnová (křížový roztěr, redukční)"],"test_object_cs":"Neselektivní agarová živná půda používaná k izolaci mikroorganismů, Legionella BCYE LAB-AGAR ™"},{"_id":"6a8326f6884ede9a1b2c5148","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka selektywna agarowa stosowana w metodzie filtracji membranowej, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1","methodology":"Żyzność","parameters":[{"name":"Żyzność","range":null}],"technique":"Metoda ilościowa, płytkowa (filtracja membranowa)","techniques":["Metoda ilościowa, płytkowa (filtracja membranowa)"],"computed":[],"activity":"Żyzność\nMetoda ilościowa, płytkowa (filtracja membranowa)","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 9308-1","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10","ISO 9308-1"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka selektywna agarowa stosowana w metodzie filtracji membranowej, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1 Żyzność\nMetoda ilościowa, płytkowa (filtracja membranowa) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 9308-1 Pozywka selektywna agarowa stosowana w metodzie filtracji membranowej, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1 Zyznosc\nMetoda ilosciowa, plytkowa (filtracja membranowa) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 9308-1","categories":["microbiology"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fertility","parameters_en":[{"name":"Fertility","range":null}],"search_en":"Selective agar medium used in the membrane filtration method, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1 Fertility Quantitative plate method (membrane filtration) Microbiology Quality Control Laboratory Quantitative plate method (membrane filtration) Fertility PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 9308-1","technique_en":"Quantitative plate method (membrane filtration)","methodology_zh":"肥力","parameters_zh":[{"name":"肥力","range":null}],"search_zh":"用于膜过滤法的选择性琼脂培养基，Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1 肥力 定量平板法（膜过滤） 质量控制实验室 微生物 定量平板法（膜过滤） 肥力 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 9308-1","technique_zh":"定量平板法（膜过滤）","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Quantitative plate method (membrane filtration)"],"test_object_en":"Selective agar medium used in the membrane filtration method, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Bodenfruchtbarkeit","parameters_de":[{"name":"Bodenfruchtbarkeit","range":null}],"search_de":"Selektiver Agarnährboden für das Membranfiltrationsverfahren, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1 Bodenfruchtbarkeit Quantitatives Verfahren, Plattenverfahren (Membranfiltration) Qualitätskontrolllabor Mikrobiologie Quantitatives Verfahren, Plattenverfahren (Membranfiltration) Bodenfruchtbarkeit PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 9308-1","technique_de":"Quantitatives Verfahren, Plattenverfahren (Membranfiltration)","techniques_de":["Quantitatives Verfahren, Plattenverfahren (Membranfiltration)"],"test_object_de":"Selektiver Agarnährboden für das Membranfiltrationsverfahren, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1","lab_section_zh":"质量控制实验室 微生物","techniques_zh":["定量平板法（膜过滤）"],"test_object_zh":"用于膜过滤法的选择性琼脂培养基，Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Úrodnost","parameters_cs":[{"name":"Úrodnost","range":null}],"search_cs":"Selektivní agarová živná půda používaná v metodě membránové filtrace, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1 Úrodnost Kvantitativní metoda, plotnová (membránová filtrace) Laboratoř kontroly kvality Mikrobiologie Kvantitativní metoda, plotnová (membránová filtrace) Úrodnost PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 9308-1","technique_cs":"Kvantitativní metoda, plotnová (membránová filtrace)","techniques_cs":["Kvantitativní metoda, plotnová (membránová filtrace)"],"test_object_cs":"Selektivní agarová živná půda používaná v metodě membránové filtrace, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1"},{"_id":"6a8326f6884ede9a1b2c5149","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka selektywna agarowa stosowana w metodzie filtracji membranowej, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1","methodology":"Specyficzność","parameters":[{"name":"Specyficzność","range":null}],"technique":"Metoda jakościowa płytkowa (posiew rysowy, redukcyjny)","techniques":["Metoda jakościowa płytkowa (posiew rysowy, redukcyjny)"],"computed":[],"activity":"Specyficzność\nMetoda jakościowa płytkowa (posiew rysowy, redukcyjny)","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 9308-1","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10","ISO 9308-1"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka selektywna agarowa stosowana w metodzie filtracji membranowej, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1 Specyficzność\nMetoda jakościowa płytkowa (posiew rysowy, redukcyjny) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 9308-1 Pozywka selektywna agarowa stosowana w metodzie filtracji membranowej, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1 Specyficznosc\nMetoda jakosciowa plytkowa (posiew rysowy, redukcyjny) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 9308-1","categories":["microbiology"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specificity","parameters_en":[{"name":"Specificity","range":null}],"search_en":"Selective agar medium used in the membrane filtration method, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1 Specificity Qualitative plate method (streak plate, reductive streak) Microbiology Quality Control Laboratory Qualitative plate method (streak plate, reductive streak) Specificity PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 9308-1","technique_en":"Qualitative plate method (streak plate, reductive streak)","methodology_zh":"特异性","parameters_zh":[{"name":"特异性","range":null}],"search_zh":"用于膜过滤法的选择性琼脂培养基，Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1 特异性 定性平板法（划线、稀释接种） 质量控制实验室 微生物 定性平板法（划线、稀释接种） 特异性 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 9308-1","technique_zh":"定性平板法（划线、稀释接种）","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Qualitative plate method (streak plate, reductive streak)"],"test_object_en":"Selective agar medium used in the membrane filtration method, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Spezifität","parameters_de":[{"name":"Spezifität","range":null}],"search_de":"Selektiver Agarnährboden für das Membranfiltrationsverfahren, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1 Spezifität Qualitatives Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren) Qualitätskontrolllabor Mikrobiologie Qualitatives Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren) Spezifität PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 9308-1","technique_de":"Qualitatives Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren)","techniques_de":["Qualitatives Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren)"],"test_object_de":"Selektiver Agarnährboden für das Membranfiltrationsverfahren, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1","lab_section_zh":"质量控制实验室 微生物","techniques_zh":["定性平板法（划线、稀释接种）"],"test_object_zh":"用于膜过滤法的选择性琼脂培养基，Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Specificita","parameters_cs":[{"name":"Specificita","range":null}],"search_cs":"Selektivní agarová živná půda používaná v metodě membránové filtrace, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1 Specificita Kvalitativní plotnová metoda (křížový roztěr, redukční) Laboratoř kontroly kvality Mikrobiologie Kvalitativní plotnová metoda (křížový roztěr, redukční) Specificita PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 9308-1","technique_cs":"Kvalitativní plotnová metoda (křížový roztěr, redukční)","techniques_cs":["Kvalitativní plotnová metoda (křížový roztěr, redukční)"],"test_object_cs":"Selektivní agarová živná půda používaná v metodě membránové filtrace, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1"},{"_id":"6a8326f6884ede9a1b2c514a","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka selektywna agarowa stosowana w metodzie filtracji membranowej, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1","methodology":"Selektywność","parameters":[{"name":"Selektywność","range":null}],"technique":"Metoda jakościowa płytkowa (posiew rysowy)","techniques":["Metoda jakościowa płytkowa (posiew rysowy)"],"computed":[],"activity":"Selektywność\nMetoda jakościowa płytkowa (posiew rysowy)","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 9308-1","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10","ISO 9308-1"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka selektywna agarowa stosowana w metodzie filtracji membranowej, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1 Selektywność\nMetoda jakościowa płytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 9308-1 Pozywka selektywna agarowa stosowana w metodzie filtracji membranowej, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1 Selektywnosc\nMetoda jakosciowa plytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 9308-1","categories":["microbiology"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Selectivity","parameters_en":[{"name":"Selectivity","range":null}],"search_en":"Selective agar medium used in the membrane filtration method, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1 Selectivity Qualitative plate method (streak plate) Microbiology Quality Control Laboratory Qualitative plate method (streak plate) Selectivity PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 9308-1","technique_en":"Qualitative plate method (streak plate)","methodology_zh":"选择性","parameters_zh":[{"name":"选择性","range":null}],"search_zh":"用于膜过滤法的选择性琼脂培养基，Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1 选择性 定性平板法（划线接种） 质量控制实验室 微生物 定性平板法（划线接种） 选择性 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 9308-1","technique_zh":"定性平板法（划线接种）","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Qualitative plate method (streak plate)"],"test_object_en":"Selective agar medium used in the membrane filtration method, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Selektivität","parameters_de":[{"name":"Selektivität","range":null}],"search_de":"Selektiver Agarnährboden für das Membranfiltrationsverfahren, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1 Selektivität Qualitatives Plattenverfahren (Ausstrichverfahren) Qualitätskontrolllabor Mikrobiologie Qualitatives Plattenverfahren (Ausstrichverfahren) Selektivität PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 9308-1","technique_de":"Qualitatives Plattenverfahren (Ausstrichverfahren)","techniques_de":["Qualitatives Plattenverfahren (Ausstrichverfahren)"],"test_object_de":"Selektiver Agarnährboden für das Membranfiltrationsverfahren, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1","lab_section_zh":"质量控制实验室 微生物","techniques_zh":["定性平板法（划线接种）"],"test_object_zh":"用于膜过滤法的选择性琼脂培养基，Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Selektivita","parameters_cs":[{"name":"Selektivita","range":null}],"search_cs":"Selektivní agarová živná půda používaná v metodě membránové filtrace, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1 Selektivita Kvalitativní plotnová metoda (křížový roztěr) Laboratoř kontroly kvality Mikrobiologie Kvalitativní plotnová metoda (křížový roztěr) Selektivita PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 | ISO 9308-1","technique_cs":"Kvalitativní plotnová metoda (křížový roztěr)","techniques_cs":["Kvalitativní plotnová metoda (křížový roztěr)"],"test_object_cs":"Selektivní agarová živná půda používaná v metodě membránové filtrace, Chromogenic Coliform LAB-AGAR acc. to ISO 9308-1"},{"_id":"6a8326f6884ede9a1b2c514b","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka agarowa nieselektywna stosowana do izolacji drobnoustrojów, Schaedler LAB-AGAR™ +5%SB, Chocolate LAB-AGAR™ + PV, Columbia LAB-AGAR™ + 5% SB, Blood LAB-AGAR™+ 5% SB","methodology":"Żyzność","parameters":[{"name":"Żyzność","range":null}],"technique":"Metoda jakościowa, płytkowa (posiew rysowy, redukcyjny)","techniques":["Metoda jakościowa, płytkowa (posiew rysowy, redukcyjny)"],"computed":[],"activity":"Żyzność\nMetoda jakościowa, płytkowa (posiew rysowy, redukcyjny)","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka agarowa nieselektywna stosowana do izolacji drobnoustrojów, Schaedler LAB-AGAR™ +5%SB, Chocolate LAB-AGAR™ + PV, Columbia LAB-AGAR™ + 5% SB, Blood LAB-AGAR™+ 5% SB Żyzność\nMetoda jakościowa, płytkowa (posiew rysowy, redukcyjny) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 Pozywka agarowa nieselektywna stosowana do izolacji drobnoustrojow, Schaedler LAB-AGAR™ +5%SB, Chocolate LAB-AGAR™ + PV, Columbia LAB-AGAR™ + 5% SB, Blood LAB-AGAR™+ 5% SB Zyznosc\nMetoda jakosciowa, plytkowa (posiew rysowy, redukcyjny) PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","categories":["construction","microbiology"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fertility","parameters_en":[{"name":"Fertility","range":null}],"search_en":"Non-selective agar medium used for the isolation of microorganisms, Schaedler LAB-AGAR™ +5%SB, Chocolate LAB-AGAR™ + PV, Columbia LAB-AGAR™ + 5% SB, Blood LAB-AGAR™+ 5% SB Fertility Qualitative plate method (streak plate, reductive streak) Microbiology Quality Control Laboratory Qualitative plate method (streak plate, reductive streak) Fertility PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_en":"Qualitative plate method (streak plate, reductive streak)","methodology_zh":"肥力","parameters_zh":[{"name":"肥力","range":null}],"search_zh":"用于微生物分离的非选择性琼脂培养基，Schaedler LAB-AGAR™ +5%SB, Chocolate LAB-AGAR™ + PV, Columbia LAB-AGAR™ + 5% SB, Blood LAB-AGAR™+ 5% SB 肥力 定性平板法（划线、稀释接种） 质量控制实验室 微生物 定性平板法（划线、稀释接种） 肥力 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_zh":"定性平板法（划线、稀释接种）","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Qualitative plate method (streak plate, reductive streak)"],"test_object_en":"Non-selective agar medium used for the isolation of microorganisms, Schaedler LAB-AGAR™ +5%SB, Chocolate LAB-AGAR™ + PV, Columbia LAB-AGAR™ + 5% SB, Blood LAB-AGAR™+ 5% SB","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Bodenfruchtbarkeit","parameters_de":[{"name":"Bodenfruchtbarkeit","range":null}],"search_de":"Nichtselektiver Agarnährboden zur Isolierung von Mikroorganismen, Schaedler LAB-AGAR™ +5%SB, Chocolate LAB-AGAR™ + PV, Columbia LAB-AGAR™ + 5% SB, Blood LAB-AGAR™+ 5% SB Bodenfruchtbarkeit Qualitatives Verfahren, Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren) Qualitätskontrolllabor Mikrobiologie Qualitatives Verfahren, Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren) Bodenfruchtbarkeit PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_de":"Qualitatives Verfahren, Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren)","techniques_de":["Qualitatives Verfahren, Plattenverfahren (Ausstrich-, Verdünnungsausstrichverfahren)"],"test_object_de":"Nichtselektiver Agarnährboden zur Isolierung von Mikroorganismen, Schaedler LAB-AGAR™ +5%SB, Chocolate LAB-AGAR™ + PV, Columbia LAB-AGAR™ + 5% SB, Blood LAB-AGAR™+ 5% SB","lab_section_zh":"质量控制实验室 微生物","techniques_zh":["定性平板法（划线、稀释接种）"],"test_object_zh":"用于微生物分离的非选择性琼脂培养基，Schaedler LAB-AGAR™ +5%SB, Chocolate LAB-AGAR™ + PV, Columbia LAB-AGAR™ + 5% SB, Blood LAB-AGAR™+ 5% SB","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Úrodnost","parameters_cs":[{"name":"Úrodnost","range":null}],"search_cs":"Neselektivní agarová živná půda používaná k izolaci mikroorganismů, Schaedler LAB-AGAR™ +5%SB, Chocolate LAB-AGAR™ + PV, Columbia LAB-AGAR™ + 5% SB, Blood LAB-AGAR™+ 5% SB Úrodnost Kvalitativní metoda, plotnová (křížový roztěr, redukční) Laboratoř kontroly kvality Mikrobiologie Kvalitativní metoda, plotnová (křížový roztěr, redukční) Úrodnost PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_cs":"Kvalitativní metoda, plotnová (křížový roztěr, redukční)","techniques_cs":["Kvalitativní metoda, plotnová (křížový roztěr, redukční)"],"test_object_cs":"Neselektivní agarová živná půda používaná k izolaci mikroorganismů, Schaedler LAB-AGAR™ +5%SB, Chocolate LAB-AGAR™ + PV, Columbia LAB-AGAR™ + 5% SB, Blood LAB-AGAR™+ 5% SB"},{"_id":"6a8326f6884ede9a1b2c514c","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka agarowa nieselektywna stosowana do izolacji drobnoustrojów, Trypticasein Soy LAB-AGAR™, Plate Count LAB-AGAR™","methodology":"Żyzność","parameters":[{"name":"Żyzność","range":null}],"technique":"Metoda ilościowa, posiew powierzchniowy","techniques":["Metoda ilościowa, posiew powierzchniowy"],"computed":[],"activity":"Żyzność\nMetoda ilościowa, posiew powierzchniowy","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka agarowa nieselektywna stosowana do izolacji drobnoustrojów, Trypticasein Soy LAB-AGAR™, Plate Count LAB-AGAR™ Żyzność\nMetoda ilościowa, posiew powierzchniowy PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 Pozywka agarowa nieselektywna stosowana do izolacji drobnoustrojow, Trypticasein Soy LAB-AGAR™, Plate Count LAB-AGAR™ Zyznosc\nMetoda ilosciowa, posiew powierzchniowy PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","categories":["construction","microbiology"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fertility","parameters_en":[{"name":"Fertility","range":null}],"search_en":"Non-selective agar medium used for the isolation of microorganisms, Trypticasein Soy LAB-AGAR™, Plate Count LAB-AGAR™ Fertility Quantitative method, spread plate Microbiology Quality Control Laboratory Quantitative method, spread plate Fertility PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_en":"Quantitative method, spread plate","methodology_zh":"肥力","parameters_zh":[{"name":"肥力","range":null}],"search_zh":"用于微生物分离的非选择性琼脂培养基，Trypticasein Soy LAB-AGAR™, Plate Count LAB-AGAR™ 肥力 定量法，表面涂布 质量控制实验室 微生物 定量法，表面涂布 肥力 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_zh":"定量法，表面涂布","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Quantitative method, spread plate"],"test_object_en":"Non-selective agar medium used for the isolation of microorganisms, Trypticasein Soy LAB-AGAR™, Plate Count LAB-AGAR™","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Bodenfruchtbarkeit","parameters_de":[{"name":"Bodenfruchtbarkeit","range":null}],"search_de":"Nichtselektiver Agarnährboden zur Isolierung von Mikroorganismen, Trypticasein Soy LAB-AGAR™, Plate Count LAB-AGAR™ Bodenfruchtbarkeit Quantitatives Verfahren, Oberflächenverfahren Qualitätskontrolllabor Mikrobiologie Quantitatives Verfahren, Oberflächenverfahren Bodenfruchtbarkeit PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_de":"Quantitatives Verfahren, Oberflächenverfahren","techniques_de":["Quantitatives Verfahren, Oberflächenverfahren"],"test_object_de":"Nichtselektiver Agarnährboden zur Isolierung von Mikroorganismen, Trypticasein Soy LAB-AGAR™, Plate Count LAB-AGAR™","lab_section_zh":"质量控制实验室 微生物","techniques_zh":["定量法，表面涂布"],"test_object_zh":"用于微生物分离的非选择性琼脂培养基，Trypticasein Soy LAB-AGAR™, Plate Count LAB-AGAR™","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Úrodnost","parameters_cs":[{"name":"Úrodnost","range":null}],"search_cs":"Neselektivní agarová živná půda používaná k izolaci mikroorganismů, Trypticasein Soy LAB-AGAR™, Plate Count LAB-AGAR™ Úrodnost Kvantitativní metoda, roztěr na povrch Laboratoř kontroly kvality Mikrobiologie Kvantitativní metoda, roztěr na povrch Úrodnost PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_cs":"Kvantitativní metoda, roztěr na povrch","techniques_cs":["Kvantitativní metoda, roztěr na povrch"],"test_object_cs":"Neselektivní agarová živná půda používaná k izolaci mikroorganismů, Trypticasein Soy LAB-AGAR™, Plate Count LAB-AGAR™"},{"_id":"6a8326f6884ede9a1b2c514d","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka płynna nieselektywna, Buffered Peptone Water, Brain Heart Infusion Broth, Thioglycollate Fluid Medium, Trypticasein Soy Broth, L.T. 100 Broth","methodology":"Żyzność","parameters":[{"name":"Żyzność","range":null}],"technique":"Metoda jakościowa probówkowa","techniques":["Metoda jakościowa probówkowa"],"computed":[],"activity":"Żyzność\nMetoda jakościowa probówkowa","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka płynna nieselektywna, Buffered Peptone Water, Brain Heart Infusion Broth, Thioglycollate Fluid Medium, Trypticasein Soy Broth, L.T. 100 Broth Żyzność\nMetoda jakościowa probówkowa PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 Pozywka plynna nieselektywna, Buffered Peptone Water, Brain Heart Infusion Broth, Thioglycollate Fluid Medium, Trypticasein Soy Broth, L.T. 100 Broth Zyznosc\nMetoda jakosciowa probowkowa PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fertility","parameters_en":[{"name":"Fertility","range":null}],"search_en":"Non-selective liquid medium, Buffered Peptone Water, Brain Heart Infusion Broth, Thioglycollate Fluid Medium, Trypticasein Soy Broth, L.T. 100 Broth Fertility Qualitative tube method Microbiology Quality Control Laboratory Qualitative tube method Fertility PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_en":"Qualitative tube method","methodology_zh":"肥力","parameters_zh":[{"name":"肥力","range":null}],"search_zh":"非选择性液体培养基，Buffered Peptone Water, Brain Heart Infusion Broth, Thioglycollate Fluid Medium, Trypticasein Soy Broth, L.T. 100 Broth 肥力 定性试管法 质量控制实验室 微生物 定性试管法 肥力 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Qualitative tube method"],"test_object_en":"Non-selective liquid medium, Buffered Peptone Water, Brain Heart Infusion Broth, Thioglycollate Fluid Medium, Trypticasein Soy Broth, L.T. 100 Broth","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Bodenfruchtbarkeit","parameters_de":[{"name":"Bodenfruchtbarkeit","range":null}],"search_de":"Nichtselektives flüssiges Nährmedium, Buffered Peptone Water, Brain Heart Infusion Broth, Thioglycollate Fluid Medium, Trypticasein Soy Broth, L.T. 100 Broth Bodenfruchtbarkeit Qualitatives Röhrchenverfahren Qualitätskontrolllabor Mikrobiologie Qualitatives Röhrchenverfahren Bodenfruchtbarkeit PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_de":"Qualitatives Röhrchenverfahren","techniques_de":["Qualitatives Röhrchenverfahren"],"test_object_de":"Nichtselektives flüssiges Nährmedium, Buffered Peptone Water, Brain Heart Infusion Broth, Thioglycollate Fluid Medium, Trypticasein Soy Broth, L.T. 100 Broth","lab_section_zh":"质量控制实验室 微生物","technique_zh":"定性试管法","techniques_zh":["定性试管法"],"test_object_zh":"非选择性液体培养基，Buffered Peptone Water, Brain Heart Infusion Broth, Thioglycollate Fluid Medium, Trypticasein Soy Broth, L.T. 100 Broth","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Úrodnost","parameters_cs":[{"name":"Úrodnost","range":null}],"search_cs":"Tekutá neselektivní živná půda, Buffered Peptone Water, Brain Heart Infusion Broth, Thioglycollate Fluid Medium, Trypticasein Soy Broth, L.T. 100 Broth Úrodnost Kvalitativní zkumavková metoda Laboratoř kontroly kvality Mikrobiologie Kvalitativní zkumavková metoda Úrodnost PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_cs":"Kvalitativní zkumavková metoda","techniques_cs":["Kvalitativní zkumavková metoda"],"test_object_cs":"Tekutá neselektivní živná půda, Buffered Peptone Water, Brain Heart Infusion Broth, Thioglycollate Fluid Medium, Trypticasein Soy Broth, L.T. 100 Broth"},{"_id":"6a8326f6884ede9a1b2c514e","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka płynna selektywno-namnażająca, MKTTn Broth, Rappaport Vassiliadis Soy Broth, Fraser Broth, Half Fraser Broth","methodology":"Żyzność","parameters":[{"name":"Żyzność","range":null}],"technique":"Metoda jakościowa, probówkowa","techniques":["Metoda jakościowa, probówkowa"],"computed":[],"activity":"Żyzność\nMetoda jakościowa, probówkowa","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka płynna selektywno-namnażająca, MKTTn Broth, Rappaport Vassiliadis Soy Broth, Fraser Broth, Half Fraser Broth Żyzność\nMetoda jakościowa, probówkowa PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 Pozywka plynna selektywno-namnazajaca, MKTTn Broth, Rappaport Vassiliadis Soy Broth, Fraser Broth, Half Fraser Broth Zyznosc\nMetoda jakosciowa, probowkowa PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fertility","parameters_en":[{"name":"Fertility","range":null}],"search_en":"Selective enrichment liquid medium, MKTTn Broth, Rappaport Vassiliadis Soy Broth, Fraser Broth, Half Fraser Broth Fertility Qualitative method, tube Microbiology Quality Control Laboratory Qualitative method, tube Fertility PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_en":"Qualitative method, tube","methodology_zh":"肥力","parameters_zh":[{"name":"肥力","range":null}],"search_zh":"选择性增菌液体培养基，MKTTn Broth、Rappaport Vassiliadis Soy Broth、Fraser Broth、Half Fraser Broth 肥力 定性法，试管法 质量控制实验室 微生物 定性法，试管法 肥力 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Qualitative method, tube"],"test_object_en":"Selective enrichment liquid medium, MKTTn Broth, Rappaport Vassiliadis Soy Broth, Fraser Broth, Half Fraser Broth","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Bodenfruchtbarkeit","parameters_de":[{"name":"Bodenfruchtbarkeit","range":null}],"search_de":"Selektives flüssiges Anreicherungsmedium, MKTTn Broth, Rappaport Vassiliadis Soy Broth, Fraser Broth, Half Fraser Broth Bodenfruchtbarkeit Qualitatives Verfahren, Röhrchenverfahren Qualitätskontrolllabor Mikrobiologie Qualitatives Verfahren, Röhrchenverfahren Bodenfruchtbarkeit PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_de":"Qualitatives Verfahren, Röhrchenverfahren","techniques_de":["Qualitatives Verfahren, Röhrchenverfahren"],"test_object_de":"Selektives flüssiges Anreicherungsmedium, MKTTn Broth, Rappaport Vassiliadis Soy Broth, Fraser Broth, Half Fraser Broth","lab_section_zh":"质量控制实验室 微生物","technique_zh":"定性法，试管法","techniques_zh":["定性法，试管法"],"test_object_zh":"选择性增菌液体培养基，MKTTn Broth、Rappaport Vassiliadis Soy Broth、Fraser Broth、Half Fraser Broth","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Úrodnost","parameters_cs":[{"name":"Úrodnost","range":null}],"search_cs":"Tekutá selektivně-pomnožovací živná půda, MKTTn Broth, Rappaport Vassiliadis Soy Broth, Fraser Broth, Half Fraser Broth Úrodnost Kvalitativní metoda, zkumavková Laboratoř kontroly kvality Mikrobiologie Kvalitativní metoda, zkumavková Úrodnost PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_cs":"Kvalitativní metoda, zkumavková","techniques_cs":["Kvalitativní metoda, zkumavková"],"test_object_cs":"Tekutá selektivně-pomnožovací živná půda, MKTTn Broth, Rappaport Vassiliadis Soy Broth, Fraser Broth, Half Fraser Broth"},{"_id":"6a8326f6884ede9a1b2c514f","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka płynna selektywno-namnażająca, MKTTn Broth, Rappaport Vassiliadis Soy Broth, Fraser Broth, Half Fraser Broth","methodology":"Selektywność","parameters":[{"name":"Selektywność","range":null}],"technique":"Metoda jakościowa, probówkowa","techniques":["Metoda jakościowa, probówkowa"],"computed":[],"activity":"Selektywność\nMetoda jakościowa, probówkowa","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka płynna selektywno-namnażająca, MKTTn Broth, Rappaport Vassiliadis Soy Broth, Fraser Broth, Half Fraser Broth Selektywność\nMetoda jakościowa, probówkowa PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 Pozywka plynna selektywno-namnazajaca, MKTTn Broth, Rappaport Vassiliadis Soy Broth, Fraser Broth, Half Fraser Broth Selektywnosc\nMetoda jakosciowa, probowkowa PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Selectivity","parameters_en":[{"name":"Selectivity","range":null}],"search_en":"Selective enrichment liquid medium, MKTTn Broth, Rappaport Vassiliadis Soy Broth, Fraser Broth, Half Fraser Broth Selectivity Qualitative method, tube Microbiology Quality Control Laboratory Qualitative method, tube Selectivity PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_en":"Qualitative method, tube","methodology_zh":"选择性","parameters_zh":[{"name":"选择性","range":null}],"search_zh":"选择性增菌液体培养基，MKTTn Broth、Rappaport Vassiliadis Soy Broth、Fraser Broth、Half Fraser Broth 选择性 定性法，试管法 质量控制实验室 微生物 定性法，试管法 选择性 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Qualitative method, tube"],"test_object_en":"Selective enrichment liquid medium, MKTTn Broth, Rappaport Vassiliadis Soy Broth, Fraser Broth, Half Fraser Broth","lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Selektivität","parameters_de":[{"name":"Selektivität","range":null}],"search_de":"Selektives flüssiges Anreicherungsmedium, MKTTn Broth, Rappaport Vassiliadis Soy Broth, Fraser Broth, Half Fraser Broth Selektivität Qualitatives Verfahren, Röhrchenverfahren Qualitätskontrolllabor Mikrobiologie Qualitatives Verfahren, Röhrchenverfahren Selektivität PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_de":"Qualitatives Verfahren, Röhrchenverfahren","techniques_de":["Qualitatives Verfahren, Röhrchenverfahren"],"test_object_de":"Selektives flüssiges Anreicherungsmedium, MKTTn Broth, Rappaport Vassiliadis Soy Broth, Fraser Broth, Half Fraser Broth","lab_section_zh":"质量控制实验室 微生物","technique_zh":"定性法，试管法","techniques_zh":["定性法，试管法"],"test_object_zh":"选择性增菌液体培养基，MKTTn Broth、Rappaport Vassiliadis Soy Broth、Fraser Broth、Half Fraser Broth","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","methodology_cs":"Selektivita","parameters_cs":[{"name":"Selektivita","range":null}],"search_cs":"Tekutá selektivně-pomnožovací živná půda, MKTTn Broth, Rappaport Vassiliadis Soy Broth, Fraser Broth, Half Fraser Broth Selektivita Kvalitativní metoda, zkumavková Laboratoř kontroly kvality Mikrobiologie Kvalitativní metoda, zkumavková Selektivita PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_cs":"Kvalitativní metoda, zkumavková","techniques_cs":["Kvalitativní metoda, zkumavková"],"test_object_cs":"Tekutá selektivně-pomnožovací živná půda, MKTTn Broth, Rappaport Vassiliadis Soy Broth, Fraser Broth, Half Fraser Broth"},{"_id":"6a8326f6884ede9a1b2c5150","lab_id":"69ad52a3de79e566650fba09","country":"PL","accr_number":"AB 1863","accr_body":"PCA","test_object":"Pożywka agarowa stosowana do izolacji drożdży i pleśni, Sabouraud Dextrose LAB-AGARTM","methodology":"Żyzność:","parameters":[{"name":"Żyzność","range":null}],"technique":"Metoda ilościowa, płytkowa, posiew powierzchniowy","techniques":["Metoda ilościowa, płytkowa, posiew powierzchniowy"],"computed":[],"activity":"Żyzność:\nŻyzność\nMetoda ilościowa, płytkowa, posiew powierzchniowy","reference":"PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","norm_bases":["PN-EN ISO 11133:2014-07","PN-EN ISO 11133:2014-07/ A1 2018-04","PN-EN ISO 11133:2014-07/ A2:2020-10"],"lab_section":"Laboratorium Kontroli Jakości Mikrobiologia","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pożywka agarowa stosowana do izolacji drożdży i pleśni, Sabouraud Dextrose LAB-AGARTM Żyzność:\nŻyzność\nMetoda ilościowa, płytkowa, posiew powierzchniowy PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10 Pozywka agarowa stosowana do izolacji drozdzy i plesni, Sabouraud Dextrose LAB-AGARTM Zyznosc:\nZyznosc\nMetoda ilosciowa, plytkowa, posiew powierzchniowy PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","categories":["construction"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fertility:","parameters_en":[{"name":"Fertility","range":null}],"search_en":"Agar medium used for the isolation of yeasts and moulds, Sabouraud Dextrose LAB-AGARTM Fertility: Quantitative, plate method, surface plating Microbiology Quality Control Laboratory Quantitative, plate method, surface plating Fertility PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_en":"Quantitative, plate method, surface plating","test_object_en":"Agar medium used for the isolation of yeasts and moulds, Sabouraud Dextrose LAB-AGARTM","parameters_zh":[{"name":"肥力","range":null}],"search_zh":"用于酵母和霉菌分离的琼脂培养基，Sabouraud Dextrose LAB-AGARTM 肥力： 定量法，平板法，表面涂布 质量控制实验室 微生物 定量法，平板法，表面涂布 肥力 PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","lab_section_en":"Microbiology Quality Control Laboratory","techniques_en":["Quantitative, plate method, surface plating"],"lab_section_de":"Qualitätskontrolllabor Mikrobiologie","methodology_de":"Bodenfruchtbarkeit:","parameters_de":[{"name":"Bodenfruchtbarkeit","range":null}],"search_de":"Agarnährboden zur Isolierung von Hefen und Schimmelpilzen, Sabouraud Dextrose LAB-AGARTM Bodenfruchtbarkeit: Quantitatives Verfahren, Plattenverfahren, Oberflächenverfahren Qualitätskontrolllabor Mikrobiologie Quantitatives Verfahren, Plattenverfahren, Oberflächenverfahren Bodenfruchtbarkeit PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","technique_de":"Quantitatives Verfahren, Plattenverfahren, Oberflächenverfahren","techniques_de":["Quantitatives Verfahren, Plattenverfahren, Oberflächenverfahren"],"test_object_de":"Agarnährboden zur Isolierung von Hefen und Schimmelpilzen, Sabouraud Dextrose LAB-AGARTM","lab_section_zh":"质量控制实验室 微生物","methodology_zh":"肥力：","technique_zh":"定量法，平板法，表面涂布","techniques_zh":["定量法，平板法，表面涂布"],"test_object_zh":"用于酵母和霉菌分离的琼脂培养基，Sabouraud Dextrose LAB-AGARTM","lab_section_cs":"Laboratoř kontroly kvality Mikrobiologie","parameters_cs":[{"name":"Úrodnost","range":null}],"search_cs":"Agarová živná půda používaná k izolaci kvasinek a plísní, Sabouraud Dextrose LAB-AGARTM Produktivita: Kvantitativní metoda, plotnová, roztěr na povrch Laboratoř kontroly kvality Mikrobiologie Kvantitativní metoda, plotnová, roztěr na povrch Úrodnost PN-EN ISO 11133:2014-07 | PN-EN ISO 11133:2014-07/ A1 2018-04 | PN-EN ISO 11133:2014-07/ A2:2020-10","methodology_cs":"Produktivita:","technique_cs":"Kvantitativní metoda, plotnová, roztěr na povrch","techniques_cs":["Kvantitativní metoda, plotnová, roztěr na povrch"],"test_object_cs":"Agarová živná půda používaná k izolaci kvasinek a plísní, Sabouraud Dextrose LAB-AGARTM"}],"has_pdf":true}