{"lab":{"_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","address":"CENTRE, ul. K. Leskiego 7, 01-499 Warszawa","categories":["water","environment","construction","materials"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":24,"name":"CENTRALNY OŚRODEK ANALIZY SKAŻEŃ / CBRN AREA CONTROL","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1857.pdf"],"scope_summary":"","search_text":"centralny ośrodek analizy skażeń / cbrn area control centre, ul. k. leskiego 7, 01-499 warszawa water metrology electronics pharma automotive other","status":"active","updated_at":"2026-03-08T14:50:59.276Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T15:26:05.346Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201857,podmiot.html","fields_of_testing":[{"codes":"C/4; C/8; C/17; C/21; C/28; C/31","pl":"Badania chemiczne wyrobów chemicznych, wyrobów i materiałów konstrukcyjnych, wyrobów innych, wyrobów z tworzyw sztucznych i gumy, wody, gleby","en":"Chemical tests of chemical products, construction products and materials, other products, plastic and rubber products, water, soil"},{"codes":"O/1; O/28; O/31","pl":"Badania radiochemiczne i promieniowania produktów rolnych, wody, gleby","en":"Radiochemical tests and tests of radiation of agricultural products, water, soil"},{"table_columns_pl":"Przedmiot badań/wyrób; Rodzaj działalności/badane cechy/metoda; Dokumenty odniesienia","table_columns_en":"Material/product tested; Type of activity/parameter/characteristic tested; Reference documents"}],"issue":{"no":"6","date":"29.04.2026"},"parse_date":"2026-08-17T15:26:05.346Z","parse_source":"agent-claude-code","map_coord":[52.262141,20.876217],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium Chemiczne / Chemical Laboratory","address":"ul. K. Leskiego 7, 01-499 Warszawa","city":"Warszawa","postal":"01-499"},{"name":"Sekcja Chemiczna / Chemical Section","address":"ul. K. Leskiego 7, 01-499 Warszawa","city":"Warszawa","postal":"01-499"},{"name":"Zespół Laboratoryjny Typu „CH” / 'CH' Laboratory Team","address":"ul. K. Leskiego 7, 01-499 Warszawa","city":"Warszawa","postal":"01-499"},{"name":"Laboratorium Radiometryczne / Radiometric Laboratory","address":"ul. K. Leskiego 7, 01-499 Warszawa","city":"Warszawa","postal":"01-499"},{"name":"Sekcja Radiometryczna / Radiometric Section","address":"ul. K. Leskiego 7, 01-499 Warszawa","city":"Warszawa","postal":"01-499"},{"name":"Zespół Laboratoryjny Typu „R” / 'R' Laboratory Team","address":"ul. K. Leskiego 7, 01-499 Warszawa","city":"Warszawa","postal":"01-499"}],"scope_format":"PCA::pracownie+elastyczny+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/35afed26c32b09fd38bd492177cfe75d/AB%201857.pdf","has_zh":true,"has_en":true,"category_counts":{"other":8,"water":6,"environment":6,"construction":2,"materials":2},"category_scores":{"other":2.67,"water":1.5,"environment":1.5,"construction":0.17,"materials":0.17},"lab_locations_zh":[{"name":"化学实验室 / Chemical Laboratory","address":"ul. K. Leskiego 7, 01-499 Warszawa","city":"Warszawa","postal":"01-499"},{"name":"Sekcja Chemiczna / Chemical Section","address":"ul. K. Leskiego 7, 01-499 Warszawa","city":"Warszawa","postal":"01-499"},{"name":"Zespół Laboratoryjny Typu „CH” / 'CH' Laboratory Team","address":"ul. K. Leskiego 7, 01-499 Warszawa","city":"Warszawa","postal":"01-499"},{"name":"Laboratorium Radiometryczne / Radiometric Laboratory","address":"ul. K. Leskiego 7, 01-499 Warszawa","city":"Warszawa","postal":"01-499"},{"name":"Sekcja Radiometryczna / Radiometric Section","address":"ul. K. Leskiego 7, 01-499 Warszawa","city":"Warszawa","postal":"01-499"},{"name":"Zespół Laboratoryjny Typu „R” / 'R' Laboratory Team","address":"ul. K. Leskiego 7, 01-499 Warszawa","city":"Warszawa","postal":"01-499"}]},"methods":[{"_id":"6a83280d884ede9a1b2c51e5","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Woda E / Water E","methodology":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","parameters":[{"name":"Zakres wykrywanych jonów / Range of detected ions","range":"(40–500) m/z"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST"],"computed":[],"activity":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","reference":"Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-03 / Instruction I-03 | Instrukcja I-05 / Instruction I-05","norm_bases":["Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland","Instrukcja I-03 / Instruction I-03","Instrukcja I-05 / Instruction I-05"],"lab_section":"Wydział Laboratoryjny / Laboratory Department; Laboratorium Chemiczne / Chemical Laboratory","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","flexible":false,"search_text":"Woda E / Water E Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-03 / Instruction I-03 | Instrukcja I-05 / Instruction I-05 Woda E / Water E Identyfikacja zwiazkow chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badan, Produkcji, Skladowania i Uzycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasow sporzadzonej w Paryzu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonow / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-03 / Instruction I-03 | Instrukcja I-05 / Instruction I-05","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"检出离子范围 / Range of detected ions","range":"(40–500) m/z"}],"search_zh":"水 E / Water E 按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993. 气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST 实验室处 / Laboratory Department；化学实验室 / Chemical Laboratory E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. 检出离子范围 / Range of detected ions Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-03 / Instruction I-03 | Instrukcja I-05 / Instruction I-05","lab_section_zh":"实验室处 / Laboratory Department；化学实验室 / Chemical Laboratory","methodology_zh":"按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","technique_zh":"气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","test_object_zh":"水 E / Water E"},{"_id":"6a83280d884ede9a1b2c51e6","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Ciecze organiczne E / Organic liquids E","methodology":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","parameters":[{"name":"Zakres wykrywanych jonów / Range of detected ions","range":"(40–500) m/z"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST"],"computed":[],"activity":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","reference":"Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-02 / Instruction I-02 | Instrukcja I-05 / Instruction I-05","norm_bases":["Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland","Instrukcja I-02 / Instruction I-02","Instrukcja I-05 / Instruction I-05"],"lab_section":"Wydział Laboratoryjny / Laboratory Department; Laboratorium Chemiczne / Chemical Laboratory","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","flexible":false,"search_text":"Ciecze organiczne E / Organic liquids E Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-02 / Instruction I-02 | Instrukcja I-05 / Instruction I-05 Ciecze organiczne E / Organic liquids E Identyfikacja zwiazkow chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badan, Produkcji, Skladowania i Uzycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasow sporzadzonej w Paryzu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonow / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-02 / Instruction I-02 | Instrukcja I-05 / Instruction I-05","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"检出离子范围 / Range of detected ions","range":"(40–500) m/z"}],"search_zh":"有机液体 E / Organic liquids E 按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993. 气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST 实验室处 / Laboratory Department；化学实验室 / Chemical Laboratory E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. 检出离子范围 / Range of detected ions Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-02 / Instruction I-02 | Instrukcja I-05 / Instruction I-05","lab_section_zh":"实验室处 / Laboratory Department；化学实验室 / Chemical Laboratory","methodology_zh":"按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","technique_zh":"气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","test_object_zh":"有机液体 E / Organic liquids E"},{"_id":"6a83280d884ede9a1b2c51e7","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Gleba E / Soil E","methodology":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","parameters":[{"name":"Zakres wykrywanych jonów / Range of detected ions","range":"(40–500) m/z"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST"],"computed":[],"activity":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","reference":"Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","norm_bases":["Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland","Instrukcja I-04 / Instruction I-04","Instrukcja I-05 / Instruction I-05"],"lab_section":"Wydział Laboratoryjny / Laboratory Department; Laboratorium Chemiczne / Chemical Laboratory","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","flexible":false,"search_text":"Gleba E / Soil E Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05 Gleba E / Soil E Identyfikacja zwiazkow chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badan, Produkcji, Skladowania i Uzycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasow sporzadzonej w Paryzu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonow / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"检出离子范围 / Range of detected ions","range":"(40–500) m/z"}],"search_zh":"土壤 E / Soil E 按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993. 气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST 实验室处 / Laboratory Department；化学实验室 / Chemical Laboratory E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. 检出离子范围 / Range of detected ions Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","lab_section_zh":"实验室处 / Laboratory Department；化学实验室 / Chemical Laboratory","methodology_zh":"按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","technique_zh":"气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","test_object_zh":"土壤 E / Soil E"},{"_id":"6a83280d884ede9a1b2c51e8","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Beton E / Concrete E","methodology":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","parameters":[{"name":"Zakres wykrywanych jonów / Range of detected ions","range":"(40–500) m/z"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST"],"computed":[],"activity":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","reference":"Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","norm_bases":["Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland","Instrukcja I-04 / Instruction I-04","Instrukcja I-05 / Instruction I-05"],"lab_section":"Wydział Laboratoryjny / Laboratory Department; Laboratorium Chemiczne / Chemical Laboratory","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","flexible":false,"search_text":"Beton E / Concrete E Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05 Beton E / Concrete E Identyfikacja zwiazkow chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badan, Produkcji, Skladowania i Uzycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasow sporzadzonej w Paryzu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonow / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","categories":["construction"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"检出离子范围 / Range of detected ions","range":"(40–500) m/z"}],"search_zh":"混凝土 E / Concrete E 按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993. 气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST 实验室处 / Laboratory Department；化学实验室 / Chemical Laboratory E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. 检出离子范围 / Range of detected ions Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","lab_section_zh":"实验室处 / Laboratory Department；化学实验室 / Chemical Laboratory","methodology_zh":"按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","technique_zh":"气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","test_object_zh":"混凝土 E / Concrete E"},{"_id":"6a83280d884ede9a1b2c51e9","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych i gumy E / Plastic and rubber products E","methodology":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","parameters":[{"name":"Zakres wykrywanych jonów / Range of detected ions","range":"(40–500) m/z"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST"],"computed":[],"activity":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","reference":"Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","norm_bases":["Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland","Instrukcja I-04 / Instruction I-04","Instrukcja I-05 / Instruction I-05"],"lab_section":"Wydział Laboratoryjny / Laboratory Department; Laboratorium Chemiczne / Chemical Laboratory","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","flexible":false,"search_text":"Wyroby z tworzyw sztucznych i gumy E / Plastic and rubber products E Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05 Wyroby z tworzyw sztucznych i gumy E / Plastic and rubber products E Identyfikacja zwiazkow chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badan, Produkcji, Skladowania i Uzycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasow sporzadzonej w Paryzu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonow / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","categories":["materials"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"检出离子范围 / Range of detected ions","range":"(40–500) m/z"}],"search_zh":"塑料与橡胶制品 E / Plastic and rubber products E 按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993. 气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST 实验室处 / Laboratory Department；化学实验室 / Chemical Laboratory E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. 检出离子范围 / Range of detected ions Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","lab_section_zh":"实验室处 / Laboratory Department；化学实验室 / Chemical Laboratory","methodology_zh":"按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","technique_zh":"气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","test_object_zh":"塑料与橡胶制品 E / Plastic and rubber products E"},{"_id":"6a83280d884ede9a1b2c51ea","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Próbki inne – wymazy z powierzchni stałych E / Other samples - wipe from solid surfaces E","methodology":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","parameters":[{"name":"Zakres wykrywanych jonów / Range of detected ions","range":"(40–500) m/z"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST"],"computed":[],"activity":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","reference":"Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","norm_bases":["Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland","Instrukcja I-04 / Instruction I-04","Instrukcja I-05 / Instruction I-05"],"lab_section":"Wydział Laboratoryjny / Laboratory Department; Laboratorium Chemiczne / Chemical Laboratory","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","flexible":false,"search_text":"Próbki inne – wymazy z powierzchni stałych E / Other samples - wipe from solid surfaces E Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05 Probki inne – wymazy z powierzchni stalych E / Other samples - wipe from solid surfaces E Identyfikacja zwiazkow chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badan, Produkcji, Skladowania i Uzycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasow sporzadzonej w Paryzu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonow / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"检出离子范围 / Range of detected ions","range":"(40–500) m/z"}],"search_zh":"其他样品 – 固体表面拭子 E / Other samples - wipe from solid surfaces E 按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993. 气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST 实验室处 / Laboratory Department；化学实验室 / Chemical Laboratory E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. 检出离子范围 / Range of detected ions Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","lab_section_zh":"实验室处 / Laboratory Department；化学实验室 / Chemical Laboratory","methodology_zh":"按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","technique_zh":"气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","test_object_zh":"其他样品 – 固体表面拭子 E / Other samples - wipe from solid surfaces E"},{"_id":"6a83280d884ede9a1b2c51eb","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Woda E / Water E","methodology":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","parameters":[{"name":"Zakres wykrywanych jonów / Range of detected ions","range":"(40–500) m/z"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST"],"computed":[],"activity":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","reference":"Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-03 / Instruction I-03 | Instrukcja I-05 / Instruction I-05","norm_bases":["Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland","Instrukcja I-03 / Instruction I-03","Instrukcja I-05 / Instruction I-05"],"lab_section":"Wydział Reagowania / Response Department; Sekcja Chemiczna / Chemical Section; Zespół Laboratoryjny Typu „CH” / 'CH' Laboratory Team; (Badania wykonywane w miejscu wskazanym przez zleceniodawcę / Testing performed at the place indicated by the client); Badania wykonywane poza siedzibą laboratorium / Testing performed off-site","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","flexible":false,"search_text":"Woda E / Water E Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-03 / Instruction I-03 | Instrukcja I-05 / Instruction I-05 Woda E / Water E Identyfikacja zwiazkow chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badan, Produkcji, Skladowania i Uzycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasow sporzadzonej w Paryzu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonow / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-03 / Instruction I-03 | Instrukcja I-05 / Instruction I-05","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"检出离子范围 / Range of detected ions","range":"(40–500) m/z"}],"search_zh":"水 E / Water E 按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993. 气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST 应急处 / Response Department；化学科 / Chemical Section；「CH」型实验室小组 / 'CH' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client）；在实验室驻地以外开展的检测 / Testing performed off-site E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. 检出离子范围 / Range of detected ions Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-03 / Instruction I-03 | Instrukcja I-05 / Instruction I-05","lab_section_zh":"应急处 / Response Department；化学科 / Chemical Section；「CH」型实验室小组 / 'CH' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client）；在实验室驻地以外开展的检测 / Testing performed off-site","methodology_zh":"按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","technique_zh":"气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","test_object_zh":"水 E / Water E"},{"_id":"6a83280d884ede9a1b2c51ec","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Ciecze organiczne E / Organic liquids E","methodology":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","parameters":[{"name":"Zakres wykrywanych jonów / Range of detected ions","range":"(40–500) m/z"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST"],"computed":[],"activity":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","reference":"Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-02 / Instruction I-02 | Instrukcja I-05 / Instruction I-05","norm_bases":["Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland","Instrukcja I-02 / Instruction I-02","Instrukcja I-05 / Instruction I-05"],"lab_section":"Wydział Reagowania / Response Department; Sekcja Chemiczna / Chemical Section; Zespół Laboratoryjny Typu „CH” / 'CH' Laboratory Team; (Badania wykonywane w miejscu wskazanym przez zleceniodawcę / Testing performed at the place indicated by the client); Badania wykonywane poza siedzibą laboratorium / Testing performed off-site","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","flexible":false,"search_text":"Ciecze organiczne E / Organic liquids E Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-02 / Instruction I-02 | Instrukcja I-05 / Instruction I-05 Ciecze organiczne E / Organic liquids E Identyfikacja zwiazkow chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badan, Produkcji, Skladowania i Uzycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasow sporzadzonej w Paryzu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonow / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-02 / Instruction I-02 | Instrukcja I-05 / Instruction I-05","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"检出离子范围 / Range of detected ions","range":"(40–500) m/z"}],"search_zh":"有机液体 E / Organic liquids E 按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993. 气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST 应急处 / Response Department；化学科 / Chemical Section；「CH」型实验室小组 / 'CH' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client）；在实验室驻地以外开展的检测 / Testing performed off-site E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. 检出离子范围 / Range of detected ions Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-02 / Instruction I-02 | Instrukcja I-05 / Instruction I-05","lab_section_zh":"应急处 / Response Department；化学科 / Chemical Section；「CH」型实验室小组 / 'CH' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client）；在实验室驻地以外开展的检测 / Testing performed off-site","methodology_zh":"按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","technique_zh":"气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","test_object_zh":"有机液体 E / Organic liquids E"},{"_id":"6a83280d884ede9a1b2c51ed","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Gleba E / Soil E","methodology":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","parameters":[{"name":"Zakres wykrywanych jonów / Range of detected ions","range":"(40–500) m/z"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST"],"computed":[],"activity":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","reference":"Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","norm_bases":["Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland","Instrukcja I-04 / Instruction I-04","Instrukcja I-05 / Instruction I-05"],"lab_section":"Wydział Reagowania / Response Department; Sekcja Chemiczna / Chemical Section; Zespół Laboratoryjny Typu „CH” / 'CH' Laboratory Team; (Badania wykonywane w miejscu wskazanym przez zleceniodawcę / Testing performed at the place indicated by the client); Badania wykonywane poza siedzibą laboratorium / Testing performed off-site","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","flexible":false,"search_text":"Gleba E / Soil E Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05 Gleba E / Soil E Identyfikacja zwiazkow chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badan, Produkcji, Skladowania i Uzycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasow sporzadzonej w Paryzu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonow / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"检出离子范围 / Range of detected ions","range":"(40–500) m/z"}],"search_zh":"土壤 E / Soil E 按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993. 气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST 应急处 / Response Department；化学科 / Chemical Section；「CH」型实验室小组 / 'CH' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client）；在实验室驻地以外开展的检测 / Testing performed off-site E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. 检出离子范围 / Range of detected ions Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","lab_section_zh":"应急处 / Response Department；化学科 / Chemical Section；「CH」型实验室小组 / 'CH' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client）；在实验室驻地以外开展的检测 / Testing performed off-site","methodology_zh":"按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","technique_zh":"气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","test_object_zh":"土壤 E / Soil E"},{"_id":"6a83280d884ede9a1b2c51ee","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Beton E / Concrete E","methodology":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","parameters":[{"name":"Zakres wykrywanych jonów / Range of detected ions","range":"(40–500) m/z"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST"],"computed":[],"activity":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","reference":"Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","norm_bases":["Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland","Instrukcja I-04 / Instruction I-04","Instrukcja I-05 / Instruction I-05"],"lab_section":"Wydział Reagowania / Response Department; Sekcja Chemiczna / Chemical Section; Zespół Laboratoryjny Typu „CH” / 'CH' Laboratory Team; (Badania wykonywane w miejscu wskazanym przez zleceniodawcę / Testing performed at the place indicated by the client); Badania wykonywane poza siedzibą laboratorium / Testing performed off-site","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","flexible":false,"search_text":"Beton E / Concrete E Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05 Beton E / Concrete E Identyfikacja zwiazkow chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badan, Produkcji, Skladowania i Uzycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasow sporzadzonej w Paryzu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonow / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","categories":["construction"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"检出离子范围 / Range of detected ions","range":"(40–500) m/z"}],"search_zh":"混凝土 E / Concrete E 按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993. 气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST 应急处 / Response Department；化学科 / Chemical Section；「CH」型实验室小组 / 'CH' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client）；在实验室驻地以外开展的检测 / Testing performed off-site E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. 检出离子范围 / Range of detected ions Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","lab_section_zh":"应急处 / Response Department；化学科 / Chemical Section；「CH」型实验室小组 / 'CH' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client）；在实验室驻地以外开展的检测 / Testing performed off-site","methodology_zh":"按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","technique_zh":"气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","test_object_zh":"混凝土 E / Concrete E"},{"_id":"6a83280d884ede9a1b2c51ef","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Wyroby z tworzyw sztucznych i gumy E / Plastic and rubber products E","methodology":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","parameters":[{"name":"Zakres wykrywanych jonów / Range of detected ions","range":"(40–500) m/z"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST"],"computed":[],"activity":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","reference":"Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","norm_bases":["Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland","Instrukcja I-04 / Instruction I-04","Instrukcja I-05 / Instruction I-05"],"lab_section":"Wydział Reagowania / Response Department; Sekcja Chemiczna / Chemical Section; Zespół Laboratoryjny Typu „CH” / 'CH' Laboratory Team; (Badania wykonywane w miejscu wskazanym przez zleceniodawcę / Testing performed at the place indicated by the client); Badania wykonywane poza siedzibą laboratorium / Testing performed off-site","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","flexible":false,"search_text":"Wyroby z tworzyw sztucznych i gumy E / Plastic and rubber products E Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05 Wyroby z tworzyw sztucznych i gumy E / Plastic and rubber products E Identyfikacja zwiazkow chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badan, Produkcji, Skladowania i Uzycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasow sporzadzonej w Paryzu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonow / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","categories":["materials"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"检出离子范围 / Range of detected ions","range":"(40–500) m/z"}],"search_zh":"塑料与橡胶制品 E / Plastic and rubber products E 按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993. 气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST 应急处 / Response Department；化学科 / Chemical Section；「CH」型实验室小组 / 'CH' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client）；在实验室驻地以外开展的检测 / Testing performed off-site E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. 检出离子范围 / Range of detected ions Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","lab_section_zh":"应急处 / Response Department；化学科 / Chemical Section；「CH」型实验室小组 / 'CH' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client）；在实验室驻地以外开展的检测 / Testing performed off-site","methodology_zh":"按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","technique_zh":"气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","test_object_zh":"塑料与橡胶制品 E / Plastic and rubber products E"},{"_id":"6a83280d884ede9a1b2c51f0","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Próbki inne – wymazy z powierzchni stałych E / Other samples - wipe from solid surfaces E","methodology":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","parameters":[{"name":"Zakres wykrywanych jonów / Range of detected ions","range":"(40–500) m/z"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST"],"computed":[],"activity":"Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","reference":"Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","norm_bases":["Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland","Instrukcja I-04 / Instruction I-04","Instrukcja I-05 / Instruction I-05"],"lab_section":"Wydział Reagowania / Response Department; Sekcja Chemiczna / Chemical Section; Zespół Laboratoryjny Typu „CH” / 'CH' Laboratory Team; (Badania wykonywane w miejscu wskazanym przez zleceniodawcę / Testing performed at the place indicated by the client); Badania wykonywane poza siedzibą laboratorium / Testing performed off-site","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","flexible":false,"search_text":"Próbki inne – wymazy z powierzchni stałych E / Other samples - wipe from solid surfaces E Identyfikacja związków chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badań, Produkcji, Składowania i Użycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasów sporządzonej w Paryżu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonów / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05 Probki inne – wymazy z powierzchni stalych E / Other samples - wipe from solid surfaces E Identyfikacja zwiazkow chemicznych zgodnie z wykazem 1,2,3 Konwencji o Zakazie Prowadzenia Badan, Produkcji, Skladowania i Uzycia Broni Chemicznej oraz o Zniszczeniu Jej Zapasow sporzadzonej w Paryzu dnia 13.01.1993 r. / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.\nZakres wykrywanych jonow / Range of detected ions (40–500) m/z\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) z zastosowaniem jonizacji elektronowej (EI) z wykorzystaniem bibliotek widm mas OCAD, VGWD, NIST / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","categories":["other"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"检出离子范围 / Range of detected ions","range":"(40–500) m/z"}],"search_zh":"其他样品 – 固体表面拭子 E / Other samples - wipe from solid surfaces E 按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993. 气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST 应急处 / Response Department；化学科 / Chemical Section；「CH」型实验室小组 / 'CH' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client）；在实验室驻地以外开展的检测 / Testing performed off-site E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity. 检出离子范围 / Range of detected ions Recommended operating procedures for analysis in the verification of chemical disarmament – University of Helsinki, Finland | Instrukcja I-04 / Instruction I-04 | Instrukcja I-05 / Instruction I-05","lab_section_zh":"应急处 / Response Department；化学科 / Chemical Section；「CH」型实验室小组 / 'CH' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client）；在实验室驻地以外开展的检测 / Testing performed off-site","methodology_zh":"按照 1993 年 1 月 13 日于巴黎签署的《关于禁止发展、生产、储存和使用化学武器及销毁此种武器的公约》附表 1、2、3 进行化学品鉴定 / Identification of chemical compounds in accordance with Schedule 1,2,3 of the Convention on the Prohibition of the Development, Production, Stockpiling and Use of Chemical Weapons and on their Destruction, signed in Paris on 13.01.1993.","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供或应要求提供。 / Flexible scope of accreditation. The scope flexibility includes the elements indicated in the DA-10 document for the scope of accreditation of testing laboratories. The list of activities carried out under the flexible scope of accreditation is made publicly available or upon request by the accredited entity.","technique_zh":"气相色谱-质谱法（GC-MS），采用电子电离（EI）并借助 OCAD、VGWD、NIST 质谱谱库 / Gas chromatography method with mass spectrometry detection (GC-MS) using electron ionization (EI) using mass spectral libraries OCAD, VGWD, NIST","test_object_zh":"其他样品 – 固体表面拭子 E / Other samples - wipe from solid surfaces E"},{"_id":"6a83280d884ede9a1b2c51f1","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Produkty rolne / Agricultural products","methodology":"Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV","parameters":[{"name":"Zakres / Range","range":"(0,01 – 40) kBq/kg"}],"technique":"Metoda spektrometrii promieniowania gamma / Gamma-ray spectrometry","techniques":["Metoda spektrometrii promieniowania gamma / Gamma-ray spectrometry"],"computed":[],"activity":"Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV\nZakres / Range (0,01 – 40) kBq/kg\nMetoda spektrometrii promieniowania gamma / Gamma-ray spectrometry","reference":"I-09 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","norm_bases":["I-09 wydanie 1 z dnia 24.10.2025","I-11 wydanie 1 z dnia 24.10.2025"],"lab_section":"Wydział Laboratoryjny / Laboratory Department; Laboratorium Radiometryczne / Radiometric Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty rolne / Agricultural products Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV\nZakres / Range (0,01 – 40) kBq/kg\nMetoda spektrometrii promieniowania gamma / Gamma-ray spectrometry I-09 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025 Produkty rolne / Agricultural products Stezenie radionuklidow gamma promieniotworczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV\nZakres / Range (0,01 – 40) kBq/kg\nMetoda spektrometrii promieniowania gamma / Gamma-ray spectrometry I-09 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","categories":["other"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围 / Range","range":"(0,01 – 40) kBq/kg"}],"search_zh":"农产品 / Agricultural products 40 – 3000 keV 能量范围内伽马放射性核素的活度浓度 / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV 伽马能谱法 / Gamma-ray spectrometry 实验室处 / Laboratory Department；放射测量实验室 / Radiometric Laboratory 范围 / Range I-09 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","lab_section_zh":"实验室处 / Laboratory Department；放射测量实验室 / Radiometric Laboratory","methodology_zh":"40 – 3000 keV 能量范围内伽马放射性核素的活度浓度 / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV","technique_zh":"伽马能谱法 / Gamma-ray spectrometry","test_object_zh":"农产品 / Agricultural products","parameters_en":[{"name":"Range","range":"(0,01 – 40) kBq/kg"}],"search_en":"Range I-09 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025"},{"_id":"6a83280d884ede9a1b2c51f2","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Produkty rolne / Agricultural products","methodology":"Stężenie radionuklidów gamma promieniotwórczych (z obliczeń) / Activity concentration of gamma-emitting radionuclides (calculation)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie radionuklidów gamma promieniotwórczych (z obliczeń) / Activity concentration of gamma-emitting radionuclides (calculation)","reference":"I-09 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","norm_bases":["I-09 wydanie 1 z dnia 24.10.2025","I-11 wydanie 1 z dnia 24.10.2025"],"lab_section":"Wydział Laboratoryjny / Laboratory Department; Laboratorium Radiometryczne / Radiometric Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty rolne / Agricultural products Stężenie radionuklidów gamma promieniotwórczych (z obliczeń) / Activity concentration of gamma-emitting radionuclides (calculation) I-09 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025 Produkty rolne / Agricultural products Stezenie radionuklidow gamma promieniotworczych (z obliczen) / Activity concentration of gamma-emitting radionuclides (calculation) I-09 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"实验室处 / Laboratory Department；放射测量实验室 / Radiometric Laboratory","methodology_zh":"伽马放射性核素活度浓度（计算得出） / Activity concentration of gamma-emitting radionuclides (calculation)","search_zh":"农产品 / Agricultural products 伽马放射性核素活度浓度（计算得出） / Activity concentration of gamma-emitting radionuclides (calculation) 实验室处 / Laboratory Department；放射测量实验室 / Radiometric Laboratory I-09 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","test_object_zh":"农产品 / Agricultural products"},{"_id":"6a83280d884ede9a1b2c51f3","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Woda / Water","methodology":"Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV","parameters":[{"name":"Zakres / Range","range":"(0,01 – 40) kBq/dm3"}],"technique":"Metoda spektrometrii promieniowania gamma / Gamma-ray spectrometry","techniques":["Metoda spektrometrii promieniowania gamma / Gamma-ray spectrometry"],"computed":[],"activity":"Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV\nZakres / Range (0,01 – 40) kBq/dm3\nMetoda spektrometrii promieniowania gamma / Gamma-ray spectrometry","reference":"I-08 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","norm_bases":["I-08 wydanie 1 z dnia 24.10.2025","I-11 wydanie 1 z dnia 24.10.2025"],"lab_section":"Wydział Laboratoryjny / Laboratory Department; Laboratorium Radiometryczne / Radiometric Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda / Water Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV\nZakres / Range (0,01 – 40) kBq/dm3\nMetoda spektrometrii promieniowania gamma / Gamma-ray spectrometry I-08 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025 Woda / Water Stezenie radionuklidow gamma promieniotworczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV\nZakres / Range (0,01 – 40) kBq/dm3\nMetoda spektrometrii promieniowania gamma / Gamma-ray spectrometry I-08 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围 / Range","range":"(0,01 – 40) kBq/dm3"}],"search_zh":"水 / Water 40 – 3000 keV 能量范围内伽马放射性核素的活度浓度 / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV 伽马能谱法 / Gamma-ray spectrometry 实验室处 / Laboratory Department；放射测量实验室 / Radiometric Laboratory 范围 / Range I-08 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","lab_section_zh":"实验室处 / Laboratory Department；放射测量实验室 / Radiometric Laboratory","methodology_zh":"40 – 3000 keV 能量范围内伽马放射性核素的活度浓度 / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV","technique_zh":"伽马能谱法 / Gamma-ray spectrometry","test_object_zh":"水 / Water","parameters_en":[{"name":"Range","range":"(0,01 – 40) kBq/dm3"}],"search_en":"Range I-08 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025"},{"_id":"6a83280d884ede9a1b2c51f4","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Woda / Water","methodology":"Stężenie radionuklidów gamma promieniotwórczych (z obliczeń) / Activity concentration of gamma-emitting radionuclides (calculation)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie radionuklidów gamma promieniotwórczych (z obliczeń) / Activity concentration of gamma-emitting radionuclides (calculation)","reference":"I-08 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","norm_bases":["I-08 wydanie 1 z dnia 24.10.2025","I-11 wydanie 1 z dnia 24.10.2025"],"lab_section":"Wydział Laboratoryjny / Laboratory Department; Laboratorium Radiometryczne / Radiometric Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda / Water Stężenie radionuklidów gamma promieniotwórczych (z obliczeń) / Activity concentration of gamma-emitting radionuclides (calculation) I-08 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025 Woda / Water Stezenie radionuklidow gamma promieniotworczych (z obliczen) / Activity concentration of gamma-emitting radionuclides (calculation) I-08 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"实验室处 / Laboratory Department；放射测量实验室 / Radiometric Laboratory","methodology_zh":"伽马放射性核素活度浓度（计算得出） / Activity concentration of gamma-emitting radionuclides (calculation)","search_zh":"水 / Water 伽马放射性核素活度浓度（计算得出） / Activity concentration of gamma-emitting radionuclides (calculation) 实验室处 / Laboratory Department；放射测量实验室 / Radiometric Laboratory I-08 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","test_object_zh":"水 / Water"},{"_id":"6a83280d884ede9a1b2c51f5","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Gleba / Soil","methodology":"Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV","parameters":[{"name":"Zakres / Range","range":"(0,01 – 40) kBq/kg"}],"technique":"Metoda spektrometrii promieniowania gamma / Gamma-ray spectrometry","techniques":["Metoda spektrometrii promieniowania gamma / Gamma-ray spectrometry"],"computed":[],"activity":"Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV\nZakres / Range (0,01 – 40) kBq/kg\nMetoda spektrometrii promieniowania gamma / Gamma-ray spectrometry","reference":"I-10 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","norm_bases":["I-10 wydanie 1 z dnia 24.10.2025","I-11 wydanie 1 z dnia 24.10.2025"],"lab_section":"Wydział Laboratoryjny / Laboratory Department; Laboratorium Radiometryczne / Radiometric Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba / Soil Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV\nZakres / Range (0,01 – 40) kBq/kg\nMetoda spektrometrii promieniowania gamma / Gamma-ray spectrometry I-10 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025 Gleba / Soil Stezenie radionuklidow gamma promieniotworczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV\nZakres / Range (0,01 – 40) kBq/kg\nMetoda spektrometrii promieniowania gamma / Gamma-ray spectrometry I-10 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围 / Range","range":"(0,01 – 40) kBq/kg"}],"search_zh":"土壤 / Soil 40 – 3000 keV 能量范围内伽马放射性核素的活度浓度 / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV 伽马能谱法 / Gamma-ray spectrometry 实验室处 / Laboratory Department；放射测量实验室 / Radiometric Laboratory 范围 / Range I-10 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","lab_section_zh":"实验室处 / Laboratory Department；放射测量实验室 / Radiometric Laboratory","methodology_zh":"40 – 3000 keV 能量范围内伽马放射性核素的活度浓度 / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV","technique_zh":"伽马能谱法 / Gamma-ray spectrometry","test_object_zh":"土壤 / Soil","parameters_en":[{"name":"Range","range":"(0,01 – 40) kBq/kg"}],"search_en":"Range I-10 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025"},{"_id":"6a83280d884ede9a1b2c51f6","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Gleba / Soil","methodology":"Stężenie radionuklidów gamma promieniotwórczych (z obliczeń) / Activity concentration of gamma-emitting radionuclides (calculation)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie radionuklidów gamma promieniotwórczych (z obliczeń) / Activity concentration of gamma-emitting radionuclides (calculation)","reference":"I-10 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","norm_bases":["I-10 wydanie 1 z dnia 24.10.2025","I-11 wydanie 1 z dnia 24.10.2025"],"lab_section":"Wydział Laboratoryjny / Laboratory Department; Laboratorium Radiometryczne / Radiometric Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba / Soil Stężenie radionuklidów gamma promieniotwórczych (z obliczeń) / Activity concentration of gamma-emitting radionuclides (calculation) I-10 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025 Gleba / Soil Stezenie radionuklidow gamma promieniotworczych (z obliczen) / Activity concentration of gamma-emitting radionuclides (calculation) I-10 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"实验室处 / Laboratory Department；放射测量实验室 / Radiometric Laboratory","methodology_zh":"伽马放射性核素活度浓度（计算得出） / Activity concentration of gamma-emitting radionuclides (calculation)","search_zh":"土壤 / Soil 伽马放射性核素活度浓度（计算得出） / Activity concentration of gamma-emitting radionuclides (calculation) 实验室处 / Laboratory Department；放射测量实验室 / Radiometric Laboratory I-10 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","test_object_zh":"土壤 / Soil"},{"_id":"6a83280d884ede9a1b2c51f7","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Produkty rolne / Agricultural products","methodology":"Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV","parameters":[{"name":"Zakres / Range","range":"(0,01 – 40) kBq/kg"}],"technique":"Metoda spektrometrii promieniowania gamma / Gamma-ray spectrometry","techniques":["Metoda spektrometrii promieniowania gamma / Gamma-ray spectrometry"],"computed":[],"activity":"Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV\nZakres / Range (0,01 – 40) kBq/kg\nMetoda spektrometrii promieniowania gamma / Gamma-ray spectrometry","reference":"I-09 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","norm_bases":["I-09 wydanie 1 z dnia 24.10.2025","I-11 wydanie 1 z dnia 24.10.2025"],"lab_section":"Wydział Reagowania / Response Department; Sekcja Radiometryczna / Radiometric Section; Zespół Laboratoryjny Typu „R” / 'R' Laboratory Team; (Badania wykonywane w miejscu wskazanym przez zleceniodawcę / Testing performed at the place indicated by the client)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty rolne / Agricultural products Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV\nZakres / Range (0,01 – 40) kBq/kg\nMetoda spektrometrii promieniowania gamma / Gamma-ray spectrometry I-09 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025 Produkty rolne / Agricultural products Stezenie radionuklidow gamma promieniotworczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV\nZakres / Range (0,01 – 40) kBq/kg\nMetoda spektrometrii promieniowania gamma / Gamma-ray spectrometry I-09 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","categories":["other"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围 / Range","range":"(0,01 – 40) kBq/kg"}],"search_zh":"农产品 / Agricultural products 40 – 3000 keV 能量范围内伽马放射性核素的活度浓度 / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV 伽马能谱法 / Gamma-ray spectrometry 应急处 / Response Department；放射测量科 / Radiometric Section；「R」型实验室小组 / 'R' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client） 范围 / Range I-09 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","lab_section_zh":"应急处 / Response Department；放射测量科 / Radiometric Section；「R」型实验室小组 / 'R' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client）","methodology_zh":"40 – 3000 keV 能量范围内伽马放射性核素的活度浓度 / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV","technique_zh":"伽马能谱法 / Gamma-ray spectrometry","test_object_zh":"农产品 / Agricultural products","parameters_en":[{"name":"Range","range":"(0,01 – 40) kBq/kg"}],"search_en":"Range I-09 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025"},{"_id":"6a83280d884ede9a1b2c51f8","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Produkty rolne / Agricultural products","methodology":"Stężenie radionuklidów gamma promieniotwórczych (z obliczeń) / Activity concentration of gamma-emitting radionuclides (calculation)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie radionuklidów gamma promieniotwórczych (z obliczeń) / Activity concentration of gamma-emitting radionuclides (calculation)","reference":"I-09 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","norm_bases":["I-09 wydanie 1 z dnia 24.10.2025","I-11 wydanie 1 z dnia 24.10.2025"],"lab_section":"Wydział Reagowania / Response Department; Sekcja Radiometryczna / Radiometric Section; Zespół Laboratoryjny Typu „R” / 'R' Laboratory Team; (Badania wykonywane w miejscu wskazanym przez zleceniodawcę / Testing performed at the place indicated by the client)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Produkty rolne / Agricultural products Stężenie radionuklidów gamma promieniotwórczych (z obliczeń) / Activity concentration of gamma-emitting radionuclides (calculation) I-09 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025 Produkty rolne / Agricultural products Stezenie radionuklidow gamma promieniotworczych (z obliczen) / Activity concentration of gamma-emitting radionuclides (calculation) I-09 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","categories":["other"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"应急处 / Response Department；放射测量科 / Radiometric Section；「R」型实验室小组 / 'R' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client）","methodology_zh":"伽马放射性核素活度浓度（计算得出） / Activity concentration of gamma-emitting radionuclides (calculation)","search_zh":"农产品 / Agricultural products 伽马放射性核素活度浓度（计算得出） / Activity concentration of gamma-emitting radionuclides (calculation) 应急处 / Response Department；放射测量科 / Radiometric Section；「R」型实验室小组 / 'R' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client） I-09 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","test_object_zh":"农产品 / Agricultural products"},{"_id":"6a83280d884ede9a1b2c51f9","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Woda / Water","methodology":"Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV","parameters":[{"name":"Zakres / Range","range":"(0,01 – 40) kBq/dm3"}],"technique":"Metoda spektrometrii promieniowania gamma / Gamma-ray spectrometry","techniques":["Metoda spektrometrii promieniowania gamma / Gamma-ray spectrometry"],"computed":[],"activity":"Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV\nZakres / Range (0,01 – 40) kBq/dm3\nMetoda spektrometrii promieniowania gamma / Gamma-ray spectrometry","reference":"I-08 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","norm_bases":["I-08 wydanie 1 z dnia 24.10.2025","I-11 wydanie 1 z dnia 24.10.2025"],"lab_section":"Wydział Reagowania / Response Department; Sekcja Radiometryczna / Radiometric Section; Zespół Laboratoryjny Typu „R” / 'R' Laboratory Team; (Badania wykonywane w miejscu wskazanym przez zleceniodawcę / Testing performed at the place indicated by the client)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda / Water Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV\nZakres / Range (0,01 – 40) kBq/dm3\nMetoda spektrometrii promieniowania gamma / Gamma-ray spectrometry I-08 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025 Woda / Water Stezenie radionuklidow gamma promieniotworczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV\nZakres / Range (0,01 – 40) kBq/dm3\nMetoda spektrometrii promieniowania gamma / Gamma-ray spectrometry I-08 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围 / Range","range":"(0,01 – 40) kBq/dm3"}],"search_zh":"水 / Water 40 – 3000 keV 能量范围内伽马放射性核素的活度浓度 / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV 伽马能谱法 / Gamma-ray spectrometry 应急处 / Response Department；放射测量科 / Radiometric Section；「R」型实验室小组 / 'R' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client） 范围 / Range I-08 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","lab_section_zh":"应急处 / Response Department；放射测量科 / Radiometric Section；「R」型实验室小组 / 'R' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client）","methodology_zh":"40 – 3000 keV 能量范围内伽马放射性核素的活度浓度 / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV","technique_zh":"伽马能谱法 / Gamma-ray spectrometry","test_object_zh":"水 / Water","parameters_en":[{"name":"Range","range":"(0,01 – 40) kBq/dm3"}],"search_en":"Range I-08 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025"},{"_id":"6a83280d884ede9a1b2c51fa","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Woda / Water","methodology":"Stężenie radionuklidów gamma promieniotwórczych (z obliczeń) / Activity concentration of gamma-emitting radionuclides (calculation)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie radionuklidów gamma promieniotwórczych (z obliczeń) / Activity concentration of gamma-emitting radionuclides (calculation)","reference":"I-08 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","norm_bases":["I-08 wydanie 1 z dnia 24.10.2025","I-11 wydanie 1 z dnia 24.10.2025"],"lab_section":"Wydział Reagowania / Response Department; Sekcja Radiometryczna / Radiometric Section; Zespół Laboratoryjny Typu „R” / 'R' Laboratory Team; (Badania wykonywane w miejscu wskazanym przez zleceniodawcę / Testing performed at the place indicated by the client)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda / Water Stężenie radionuklidów gamma promieniotwórczych (z obliczeń) / Activity concentration of gamma-emitting radionuclides (calculation) I-08 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025 Woda / Water Stezenie radionuklidow gamma promieniotworczych (z obliczen) / Activity concentration of gamma-emitting radionuclides (calculation) I-08 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"应急处 / Response Department；放射测量科 / Radiometric Section；「R」型实验室小组 / 'R' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client）","methodology_zh":"伽马放射性核素活度浓度（计算得出） / Activity concentration of gamma-emitting radionuclides (calculation)","search_zh":"水 / Water 伽马放射性核素活度浓度（计算得出） / Activity concentration of gamma-emitting radionuclides (calculation) 应急处 / Response Department；放射测量科 / Radiometric Section；「R」型实验室小组 / 'R' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client） I-08 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","test_object_zh":"水 / Water"},{"_id":"6a83280d884ede9a1b2c51fb","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Gleba / Soil","methodology":"Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV","parameters":[{"name":"Zakres / Range","range":"(0,01 – 40) kBq/kg"}],"technique":"Metoda spektrometrii promieniowania gamma / Gamma-ray spectrometry","techniques":["Metoda spektrometrii promieniowania gamma / Gamma-ray spectrometry"],"computed":[],"activity":"Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV\nZakres / Range (0,01 – 40) kBq/kg\nMetoda spektrometrii promieniowania gamma / Gamma-ray spectrometry","reference":"I-10 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","norm_bases":["I-10 wydanie 1 z dnia 24.10.2025","I-11 wydanie 1 z dnia 24.10.2025"],"lab_section":"Wydział Reagowania / Response Department; Sekcja Radiometryczna / Radiometric Section; Zespół Laboratoryjny Typu „R” / 'R' Laboratory Team; (Badania wykonywane w miejscu wskazanym przez zleceniodawcę / Testing performed at the place indicated by the client)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba / Soil Stężenie radionuklidów gamma promieniotwórczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV\nZakres / Range (0,01 – 40) kBq/kg\nMetoda spektrometrii promieniowania gamma / Gamma-ray spectrometry I-10 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025 Gleba / Soil Stezenie radionuklidow gamma promieniotworczych w zakresie energii: 40 – 3000 keV / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV\nZakres / Range (0,01 – 40) kBq/kg\nMetoda spektrometrii promieniowania gamma / Gamma-ray spectrometry I-10 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围 / Range","range":"(0,01 – 40) kBq/kg"}],"search_zh":"土壤 / Soil 40 – 3000 keV 能量范围内伽马放射性核素的活度浓度 / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV 伽马能谱法 / Gamma-ray spectrometry 应急处 / Response Department；放射测量科 / Radiometric Section；「R」型实验室小组 / 'R' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client） 范围 / Range I-10 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","lab_section_zh":"应急处 / Response Department；放射测量科 / Radiometric Section；「R」型实验室小组 / 'R' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client）","methodology_zh":"40 – 3000 keV 能量范围内伽马放射性核素的活度浓度 / Activity concentration of gamma-emitting radionuclides in energy range 40 – 3000 keV","technique_zh":"伽马能谱法 / Gamma-ray spectrometry","test_object_zh":"土壤 / Soil","parameters_en":[{"name":"Range","range":"(0,01 – 40) kBq/kg"}],"search_en":"Range I-10 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025"},{"_id":"6a83280d884ede9a1b2c51fc","lab_id":"69ad52a3de79e566650fb9fd","country":"PL","accr_number":"AB 1857","accr_body":"PCA","test_object":"Gleba / Soil","methodology":"Stężenie radionuklidów gamma promieniotwórczych (z obliczeń) / Activity concentration of gamma-emitting radionuclides (calculation)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie radionuklidów gamma promieniotwórczych (z obliczeń) / Activity concentration of gamma-emitting radionuclides (calculation)","reference":"I-10 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","norm_bases":["I-10 wydanie 1 z dnia 24.10.2025","I-11 wydanie 1 z dnia 24.10.2025"],"lab_section":"Wydział Reagowania / Response Department; Sekcja Radiometryczna / Radiometric Section; Zespół Laboratoryjny Typu „R” / 'R' Laboratory Team; (Badania wykonywane w miejscu wskazanym przez zleceniodawcę / Testing performed at the place indicated by the client)","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba / Soil Stężenie radionuklidów gamma promieniotwórczych (z obliczeń) / Activity concentration of gamma-emitting radionuclides (calculation) I-10 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025 Gleba / Soil Stezenie radionuklidow gamma promieniotworczych (z obliczen) / Activity concentration of gamma-emitting radionuclides (calculation) I-10 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"应急处 / Response Department；放射测量科 / Radiometric Section；「R」型实验室小组 / 'R' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client）","methodology_zh":"伽马放射性核素活度浓度（计算得出） / Activity concentration of gamma-emitting radionuclides (calculation)","search_zh":"土壤 / Soil 伽马放射性核素活度浓度（计算得出） / Activity concentration of gamma-emitting radionuclides (calculation) 应急处 / Response Department；放射测量科 / Radiometric Section；「R」型实验室小组 / 'R' Laboratory Team；（在委托方指定地点开展的检测 / Testing performed at the place indicated by the client） I-10 wydanie 1 z dnia 24.10.2025 | I-11 wydanie 1 z dnia 24.10.2025","test_object_zh":"土壤 / Soil"}],"has_pdf":true}