{"lab":{"_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","address":"ul. Aleja Piastów 4B/34, 44-193 Knurów","categories":["environment","construction","water"],"city":"Knurów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":29,"name":"IK EKO IWONA KOPIŃSKA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1855.pdf"],"scope_summary":"","search_text":"ik eko iwona kopińska ul. aleja piastów 4b/34, 44-193 knurów environment materials other construction electronics metrology water","status":"active","updated_at":"2026-03-08T14:50:59.110Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:59.110Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201855,podmiot.html","fields_of_testing":[{"codes":"− C/33","pl":"− Badania chemiczne – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests - working environment (harmful factors - air)"},{"codes":"− G/33","pl":"− Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, drgania, oświetlenie, mikroklimat)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – noise, vibration, lighting, microclimate)"},{"codes":"− N/33/P","pl":"− Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling - working environment (harmful factors - air)"},{"codes":"− P/33","pl":"− Pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Sampling - working environment (harmful factors - air)"},{"codes":"− N/30/P","pl":"− Badania właściwości fizycznych i pobieranie próbek ścieków","en":"Tests of physical properties and sampling of sewage"}],"issue":{"no":"4","date":"24.11.2025"},"parse_date":"2026-07-20T07:09:30.646Z","parse_source":"script-pdfplumber","map_coord":[50.190812,18.624596],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":27,"construction":2,"water":2,"materials":1},"category_scores":{"environment":22.78,"construction":0.13,"water":0.13,"materials":0.03},"has_zh":true},"methods":[{"_id":"6a5dc9aaf1c10c8ce825a23c","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"},{"name":"substancje organiczne, w tym – frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym – frakcja torakalna – frakcja respirabilna"},{"name":"metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna"},{"name":"azbest – włókna respirabilne"},{"name":"sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne"}],"parameters_en":[{"name":"dust agents – inhalable fraction – respirable fraction"},{"name":"organic substances, including – inhalable fraction"},{"name":"inorganic substances, including – thoracic fraction – respirable fraction"},{"name":"metals and their compounds, including – inhalable fraction – respirable fraction"},{"name":"asbestos – respirable fibres"},{"name":"man-made mineral fibres, excluding refractory ceramic fibres – respirable fibres"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"technique_en":"Personal dosimetry method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja torakalna – frakcja respirabilna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nazbest – włókna respirabilne\nsztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja torakalna – frakcja respirabilna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nazbest – włókna respirabilne\nsztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja torakalna – frakcja respirabilna\nmetale i ich zwiazki, w tym – frakcja wdychalna – frakcja respirabilna\nazbest – wlokna respirabilne\nsztuczne wlokna mineralne, z wyjatkiem ogniotrwalych wlokien ceramicznych – wlokna respirabilne\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["materials","environment"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction inorganic substances, including – thoracic fraction – respirable fraction metals and their compounds, including – inhalable fraction – respirable fraction asbestos – respirable fibres man-made mineral fibres, excluding refractory ceramic fibres – respirable fibres PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因素 — 可吸入组分 — 呼吸性组分 有机物质，包括 — 可吸入组分 金属及其化合物，包括 — 可吸入组分 — 呼吸性组分 石棉 — 呼吸性纤维 人造矿物纤维，耐火陶瓷纤维除外 － 呼吸性纤维 PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"},{"name":"有机物质，包括 — 可吸入组分"},{"name":"substancje nieorganiczne, w tym – frakcja torakalna – frakcja respirabilna"},{"name":"金属及其化合物，包括 — 可吸入组分 — 呼吸性组分"},{"name":"石棉 — 呼吸性纤维"},{"name":"人造矿物纤维，耐火陶瓷纤维除外 － 呼吸性纤维"}]},{"_id":"6a5dc9aaf1c10c8ce825a23d","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Pobieranie próbek do oceny narażenia zawodowego na substancje nieorganiczne","methodology_en":"Sampling for occupational exposure assessment to inorganic substances","parameters":[],"parameters_en":[],"technique":"Metoda stacjonarna","techniques":["Metoda stacjonarna"],"technique_en":"Stationary method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na substancje nieorganiczne\nMetoda stacjonarna","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na substancje nieorganiczne\nMetoda stacjonarna PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na substancje nieorganiczne\nMetoda stacjonarna PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Sampling for occupational exposure assessment to inorganic substances Stationary method PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","search_zh":"工作场所环境 — 空气 定点测定法 PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","test_object_zh":"工作场所环境 — 空气","technique_zh":"定点测定法"},{"_id":"6a5dc9aaf1c10c8ce825a23e","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Wskaźnik narażenia (z obliczeń)","methodology_en":"Exposure index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5dc9aaf1c10c8ce825a23f","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie tlenku węgla","methodology_en":"Carbon monoxide concentration","parameters":[{"name":"Zakres","range":"(2,3 – 127) mg/m3"},{"name":"Zakres","range":"(2,0 – 110) ppm"}],"parameters_en":[{"name":"Range","range":"(2,3 – 127) mg/m3"},{"name":"Range","range":"(2,0 – 110) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 127) mg/m3\nZakres (2,0 – 110) ppm\nMetoda elektrochemiczna","reference":"PB-01 wydanie 5 z dnia 07.11.2024 r.","norm_bases":["PB-01 wydanie 5 z dnia 07.11.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 127) mg/m3\nZakres (2,0 – 110) ppm\nMetoda elektrochemiczna PB-01 wydanie 5 z dnia 07.11.2024 r. Srodowisko pracy - powietrze Stezenie tlenku wegla\nZakres:\nZakres (2,3 – 127) mg/m3\nZakres (2,0 – 110) ppm\nMetoda elektrochemiczna PB-01 wydanie 5 z dnia 07.11.2024 r.","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Carbon monoxide concentration Electrochemical method Range Range PB-01 wydanie 5 z dnia 07.11.2024 r.","parameters_zh":[{"name":"范围","range":"(2,3 – 127) mg/m3"},{"name":"范围","range":"(2,0 – 110) ppm"}],"search_zh":"工作场所环境 — 空气 一氧化碳浓度 电化学法 范围 范围 PB-01 wydanie 5 z dnia 07.11.2024 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"一氧化碳浓度"},{"_id":"6a5dc9aaf1c10c8ce825a240","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Wskaźniki narażenia (z obliczeń)","methodology_en":"Exposure indices (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźniki narażenia (z obliczeń)","reference":"PB-01 wydanie 5 z dnia 07.11.2024 r.","norm_bases":["PB-01 wydanie 5 z dnia 07.11.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Wskaźniki narażenia (z obliczeń) PB-01 wydanie 5 z dnia 07.11.2024 r. Srodowisko pracy - powietrze Wskazniki narazenia (z obliczen) PB-01 wydanie 5 z dnia 07.11.2024 r.","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Exposure indices (calculated) PB-01 wydanie 5 z dnia 07.11.2024 r.","search_zh":"工作场所环境 — 空气 暴露指数（计算值） PB-01 wydanie 5 z dnia 07.11.2024 r.","test_object_zh":"工作场所环境 — 空气","methodology_zh":"暴露指数（计算值）"},{"_id":"6a5dc9aaf1c10c8ce825a241","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie gazów","methodology_en":"Gas concentrations","parameters":[{"name":"tlenek azotu","range":"(0,25 – 6,2) mg/m3"},{"name":"Zakres","range":"(0,20 – 5,0) ppm"},{"name":"ditlenek azotu","range":"(0,19 – 1,9) mg/m3"},{"name":"(0,10 – 1,0) ppm"}],"parameters_en":[{"name":"nitrogen oxide","range":"(0,25 – 6,2) mg/m3"},{"name":"Range","range":"(0,20 – 5,0) ppm"},{"name":"nitrogen dioxide","range":"(0,19 – 1,9) mg/m3"},{"name":"(0,10 – 1,0) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie gazów\nZakres:\ntlenek azotu (0,25 – 6,2) mg/m3\nZakres (0,20 – 5,0) ppm\nditlenek azotu (0,19 – 1,9) mg/m3\n(0,10 – 1,0) ppm\nMetoda elektrochemiczna","reference":"PB-03 wydanie 4 z dnia 07.11.2024 r.","norm_bases":["PB-03 wydanie 4 z dnia 07.11.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie gazów\nZakres:\ntlenek azotu (0,25 – 6,2) mg/m3\nZakres (0,20 – 5,0) ppm\nditlenek azotu (0,19 – 1,9) mg/m3\n(0,10 – 1,0) ppm\nMetoda elektrochemiczna PB-03 wydanie 4 z dnia 07.11.2024 r. Srodowisko pracy - powietrze Stezenie gazow\nZakres:\ntlenek azotu (0,25 – 6,2) mg/m3\nZakres (0,20 – 5,0) ppm\nditlenek azotu (0,19 – 1,9) mg/m3\n(0,10 – 1,0) ppm\nMetoda elektrochemiczna PB-03 wydanie 4 z dnia 07.11.2024 r.","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Gas concentrations Electrochemical method nitrogen oxide Range nitrogen dioxide (0,10 – 1,0) ppm PB-03 wydanie 4 z dnia 07.11.2024 r.","parameters_zh":[{"name":"一氧化氮","range":"(0,25 – 6,2) mg/m3"},{"name":"范围","range":"(0,20 – 5,0) ppm"},{"name":"二氧化氮","range":"(0,19 – 1,9) mg/m3"},{"name":"(0,10 – 1,0) ppm"}],"search_zh":"工作场所环境 — 空气 气体浓度 电化学法 一氧化氮 范围 二氧化氮 PB-03 wydanie 4 z dnia 07.11.2024 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"气体浓度"},{"_id":"6a5dc9aaf1c10c8ce825a242","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Wskaźniki narażenia (z obliczeń)","methodology_en":"Exposure indices (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźniki narażenia (z obliczeń)","reference":"PB-03 wydanie 4 z dnia 07.11.2024 r.","norm_bases":["PB-03 wydanie 4 z dnia 07.11.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Wskaźniki narażenia (z obliczeń) PB-03 wydanie 4 z dnia 07.11.2024 r. Srodowisko pracy - powietrze Wskazniki narazenia (z obliczen) PB-03 wydanie 4 z dnia 07.11.2024 r.","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Exposure indices (calculated) PB-03 wydanie 4 z dnia 07.11.2024 r.","search_zh":"工作场所环境 — 空气 暴露指数（计算值） PB-03 wydanie 4 z dnia 07.11.2024 r.","test_object_zh":"工作场所环境 — 空气","methodology_zh":"暴露指数（计算值）"},{"_id":"6a5dc9aaf1c10c8ce825a243","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:","methodology_en":"Concentration of harmful dust agents - inhalable fraction:","parameters":[{"name":"Asfalt naftowy"},{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Sadza techniczna"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,2 – 17) mg/m3"}],"parameters_en":[{"name":"Petroleum bitumen"},{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Carbon black"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Range","range":"(0,2 – 17) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,2 – 17) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,2 – 17) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,2 – 17) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Concentration of harmful dust agents - inhalable fraction: Gravimetric method Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","parameters_zh":[{"name":"石油沥青"},{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,2 – 17) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分： 重量法 石油沥青 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分："},{"_id":"6a5dc9aaf1c10c8ce825a244","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:","methodology_en":"Concentration of harmful dust agents - respirable fraction:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,1 –10) mg/m3"}],"parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,1 –10) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,1 –10) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,1 –10) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nTalk\nWegiel (kamienny, brunatny)\nZakres (0,1 –10) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Concentration of harmful dust agents - respirable fraction: Gravimetric method Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,1 –10) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分： 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分："},{"_id":"6a5dc9aaf1c10c8ce825a245","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy – hałas","test_object_en":"Workplace environment – noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters":[{"name":"Zakres","range":"(40 – 136) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(50 – 136) dB"}],"parameters_en":[{"name":"Range","range":"(40 – 136) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(50 – 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (40 – 136) dB\nSzczytowy poziom dźwięku C\nZakres (50 – 136) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (40 – 136) dB\nSzczytowy poziom dźwięku C\nZakres (50 – 136) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (40 – 136) dB\nSzczytowy poziom dzwieku C\nZakres (50 – 136) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(40 – 136) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(50 – 136) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5dc9aaf1c10c8ce825a246","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy – hałas","test_object_en":"Workplace environment – noise","methodology":"Poziom ekspozycji na hałas odniesiony do:","methodology_en":"Noise exposure level referred to:","parameters":[{"name":"8-godzinnego dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5dc9aaf1c10c8ce825a247","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy – hałas ultradźwiękowy","test_object_en":"Workplace environment – ultrasonic noise","methodology":"Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz","methodology_en":"Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz","parameters":[{"name":"Zakres","range":"(50 – 136) dB"}],"parameters_en":[{"name":"Range","range":"(50 – 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz\nZakres (50 – 136) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-Z-01339:2020-12","norm_bases":["PN-Z-01339:2020-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – hałas ultradźwiękowy Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz\nZakres (50 – 136) dB\nMetoda pomiarowa bezpośrednia PN-Z-01339:2020-12 Srodowisko pracy – halas ultradzwiekowy Rownowazny poziom cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz Maksymalny poziom cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz\nZakres (50 – 136) dB\nMetoda pomiarowa bezposrednia PN-Z-01339:2020-12","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – ultrasonic noise Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Direct measurement method Range PN-Z-01339:2020-12","parameters_zh":[{"name":"范围","range":"(50 – 136) dB"}],"search_zh":"工作场所环境 — 超声噪声 中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级 中心频率自 10 kHz 至 40 kHz 的1/3倍频程最大声压级 直接测量法 范围 PN-Z-01339:2020-12","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 超声噪声","methodology_zh":"中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级 中心频率自 10 kHz 至 40 kHz 的1/3倍频程最大声压级"},{"_id":"6a5dc9aaf1c10c8ce825a248","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy – hałas ultradźwiękowy","test_object_en":"Workplace environment – ultrasonic noise","methodology":"Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesiony do:","methodology_en":"Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz referred to:","parameters":[{"name":"8 - godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesiony do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-Z-01339:2020-12","norm_bases":["PN-Z-01339:2020-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – hałas ultradźwiękowy Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesiony do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-Z-01339:2020-12 Srodowisko pracy – halas ultradzwiekowy Rownowazny poziom cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz odniesiony do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-Z-01339:2020-12","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – ultrasonic noise Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz referred to: an 8-hour daily working time the average weekly working time (calculated) PN-Z-01339:2020-12","parameters_zh":[{"name":"每日 8 小时工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 超声噪声 中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级，参照： 每日 8 小时工作时间 平均每周工作时间（计算值） PN-Z-01339:2020-12","test_object_zh":"工作场所环境 — 超声噪声","methodology_zh":"中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级，参照："},{"_id":"6a5dc9aaf1c10c8ce825a249","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment – indoor electric lighting","methodology":"Natężenie oświetlenia","methodology_en":"Illuminance","parameters":[{"name":"Zakres","range":"(5 – 9800) lx"}],"parameters_en":[{"name":"Range","range":"(5 – 9800) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie oświetlenia\nZakres (5 – 9800) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03 | PB-02 wydanie 2 z dnia 19.12.2022 r.","norm_bases":["PN-83/E-04040.03","PB-02 wydanie 2 z dnia 19.12.2022 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5 – 9800) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 | PB-02 wydanie 2 z dnia 19.12.2022 r. Srodowisko pracy – oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5 – 9800) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03 | PB-02 wydanie 2 z dnia 19.12.2022 r.","categories":["environment"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – indoor electric lighting Illuminance Direct measurement method Range PN-83/E-04040.03 | PB-02 wydanie 2 z dnia 19.12.2022 r.","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 9800) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 范围 PN-83/E-04040.03 | PB-02 wydanie 2 z dnia 19.12.2022 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a5dc9aaf1c10c8ce825a24a","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment – indoor electric lighting","methodology":"Równomierność oświetlenia (z obliczeń), Równomierność oświetlenia","methodology_en":"Illuminance uniformity (calculated), Illuminance uniformity","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia (z obliczeń), Równomierność oświetlenia","reference":"PN-83/E-04040.03 | PB-02 wydanie 2 z dnia 19.12.2022 r.","norm_bases":["PN-83/E-04040.03","PB-02 wydanie 2 z dnia 19.12.2022 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń), Równomierność oświetlenia PN-83/E-04040.03 | PB-02 wydanie 2 z dnia 19.12.2022 r. Srodowisko pracy – oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen), Rownomiernosc oswietlenia PN-83/E-04040.03 | PB-02 wydanie 2 z dnia 19.12.2022 r.","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – indoor electric lighting Illuminance uniformity (calculated), Illuminance uniformity PN-83/E-04040.03 | PB-02 wydanie 2 z dnia 19.12.2022 r.","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（由计算得出）、照度均匀度 PN-83/E-04040.03 | PB-02 wydanie 2 z dnia 19.12.2022 r.","test_object_zh":"工作场所环境 — 室内电气照明","methodology_zh":"照度均匀度（由计算得出）、照度均匀度"},{"_id":"6a5dc9aaf1c10c8ce825a24b","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie awaryjne","test_object_en":"Workplace environment – emergency lighting","methodology":"Natężenie oświetlenia","methodology_en":"Illuminance","parameters":[{"name":"Zakres","range":"(0,5 – 500) lx"}],"parameters_en":[{"name":"Range","range":"(0,5 – 500) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie oświetlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.7; 4.3 ; 4.4 ; 4.5 ; 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.7; 4.3 ; 4.4 ; 4.5 ; 5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – oświetlenie awaryjne Natężenie oświetlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezpośrednia PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.7; 4.3 ; 4.4 ; 4.5 ; 5 Srodowisko pracy – oswietlenie awaryjne Natezenie oswietlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezposrednia PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3-4.2.7; 4.3 ; 4.4 ; 4.5 ; 5","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – emergency lighting Illuminance Direct measurement method Range PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.7; 4.3 ; 4.4 ; 4.5 ; 5","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 – 500) lx"}],"search_zh":"工作场所环境 — 应急照明 照度 直接测量法 范围 PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.7; 4.3 ; 4.4 ; 4.5 ; 5","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a5dc9aaf1c10c8ce825a24c","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie awaryjne","test_object_en":"Workplace environment – emergency lighting","methodology":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","methodology_en":"Ratio of minimum to maximum illuminance (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.7; 4.3 ; 4.4 ; 4.5 ; 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.7; 4.3 ; 4.4 ; 4.5 ; 5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – oświetlenie awaryjne Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.7; 4.3 ; 4.4 ; 4.5 ; 5 Srodowisko pracy – oswietlenie awaryjne Stosunek minimalnego do maksymalnego natezenia oswietlenia (z obliczen) PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3-4.2.7; 4.3 ; 4.4 ; 4.5 ; 5","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – emergency lighting Ratio of minimum to maximum illuminance (calculated) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.7; 4.3 ; 4.4 ; 4.5 ; 5","methodology_zh":"最小与最大照度之比（计算值）","search_zh":"工作场所环境 — 应急照明 最小与最大照度之比（计算值） PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.7; 4.3 ; 4.4 ; 4.5 ; 5","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a5dc9aaf1c10c8ce825a24d","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","test_object_en":"Workplace environment – hand-arm vibration","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters":[{"name":"Zakres","range":"(0,3 – 100) m/s2"}],"parameters_en":[{"name":"Range","range":"(0,3 – 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,3 – 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,3 – 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,3 – 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,3 – 100) m/s2"}],"search_zh":"工作场所环境 — 手传振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a5dc9aaf1c10c8ce825a24e","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","test_object_en":"Workplace environment – hand-arm vibration","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","search_zh":"工作场所环境 — 手传振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 — 手传振动","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）"},{"_id":"6a5dc9aaf1c10c8ce825a24f","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","test_object_en":"Workplace environment – whole-body vibration","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters":[{"name":"Zakres","range":"(0,03 – 50) m/s2"}],"parameters_en":[{"name":"Range","range":"(0,03 – 50) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 – 50) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 – 50) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,03 – 50) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN 14253+A1:2011","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,03 – 50) m/s2"}],"search_zh":"工作场所环境 — 全身振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a5dc9aaf1c10c8ce825a250","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","test_object_en":"Workplace environment – whole-body vibration","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4 awx, 1.4 awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4 awx, 1.4 awy, awz) (z obliczeń)","methodology_en":"Daily exposure, expressed as the energy-equivalent for 8 hours of action root-mean-square, frequency-corrected vibration acceleration, dominant among the vibration accelerations determined for the three directional components taking into account the relevant factors (1.4 awx, 1.4 awy, awz), Exposure lasting 30 minutes and less, expressed as the root-mean-square, frequency-weighted vibration acceleration, dominant among the vibration accelerations determined for the three directional components taking into account the relevant factors (1.4 awx, 1.4 awy, awz) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4 awx, 1.4 awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4 awx, 1.4 awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4 awx, 1.4 awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4 awx, 1.4 awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4 awx, 1.4 awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4 awx, 1.4 awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – whole-body vibration Daily exposure, expressed as the energy-equivalent for 8 hours of action root-mean-square, frequency-corrected vibration acceleration, dominant among the vibration accelerations determined for the three directional components taking into account the relevant factors (1.4 awx, 1.4 awy, awz), Exposure lasting 30 minutes and less, expressed as the root-mean-square, frequency-weighted vibration acceleration, dominant among the vibration accelerations determined for the three directional components taking into account the relevant factors (1.4 awx, 1.4 awy, awz) (calculated) PN-EN 14253+A1:2011","search_zh":"工作场所环境 — 全身振动 日暴露量，以所测定振动加速度中占主导的频率计权有效振动加速度的8小时能量等效值表示 PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动","methodology_zh":"日暴露量，以所测定振动加速度中占主导的频率计权有效振动加速度的8小时能量等效值表示"},{"_id":"6a5dc9aaf1c10c8ce825a251","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","test_object_en":"Workplace environment – cold microclimate","methodology":"Temperatura powietrza","methodology_en":"Air temperature","parameters":[{"name":"Zakres","range":"(-30 – 10) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-30 – 10) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(25 – 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,4 – 10,0) m/s"}],"parameters_en":[{"name":"Range","range":"(-30 – 10) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-30 – 10) °C"},{"name":"Air humidity"},{"name":"Range","range":"(25 – 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,4 – 10,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 10) °C\nWilgotność powietrza\nZakres (25 – 90) %\nPrędkość powietrza\nZakres (0,4 – 10,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 10) °C\nWilgotność powietrza\nZakres (25 – 90) %\nPrędkość powietrza\nZakres (0,4 – 10,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy – mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 10) °C\nWilgotnosc powietrza\nZakres (25 – 90) %\nPredkosc powietrza\nZakres (0,4 – 10,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – cold microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-30 – 10) °C"},{"name":"黑球温度"},{"name":"范围","range":"(-30 – 10) °C"},{"name":"空气湿度"},{"name":"范围","range":"(25 – 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,4 – 10,0) m/s"}],"search_zh":"工作场所环境 — 低温微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a5dc9aaf1c10c8ce825a252","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","test_object_en":"Workplace environment – cold microclimate","methodology":"Wskaźnik tWC, Wskaźnik IREQmin, Wskaźnik IREQneutral (z obliczeń)","methodology_en":"tWC index, IREQmin index, IREQneutral index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik tWC, Wskaźnik IREQmin, Wskaźnik IREQneutral (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat zimny Wskaźnik tWC, Wskaźnik IREQmin, Wskaźnik IREQneutral (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy – mikroklimat zimny Wskaznik tWC, Wskaznik IREQmin, Wskaznik IREQneutral (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – cold microclimate tWC index, IREQmin index, IREQneutral index (calculated) PN-EN ISO 11079:2008","search_zh":"工作场所环境 — 低温微气候 tWC 指数、IREQmin 指数、IREQneutral 指数（由计算得出） PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 — 低温微气候","methodology_zh":"tWC 指数、IREQmin 指数、IREQneutral 指数（由计算得出）"},{"_id":"6a5dc9aaf1c10c8ce825a253","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","test_object_en":"Workplace environment – moderate microclimate","methodology":"Temperatura powietrza","methodology_en":"Air temperature","parameters":[{"name":"Zakres","range":"(10 – 30) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 40) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(25 – 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 1,0) m/s"}],"parameters_en":[{"name":"Range","range":"(10 – 30) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 – 40) °C"},{"name":"Air humidity"},{"name":"Range","range":"(25 – 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 1,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 30) °C\nTemperatura poczernionej kuli\nZakres (10 – 40) °C\nWilgotność powietrza\nZakres (25 – 90) %\nPrędkość powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 30) °C\nTemperatura poczernionej kuli\nZakres (10 – 40) °C\nWilgotność powietrza\nZakres (25 – 90) %\nPrędkość powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 30) °C\nTemperatura poczernionej kuli\nZakres (10 – 40) °C\nWilgotnosc powietrza\nZakres (25 – 90) %\nPredkosc powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – moderate microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 30) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 – 40) °C"},{"name":"空气湿度"},{"name":"范围","range":"(25 – 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 1,0) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a5dc9aaf1c10c8ce825a254","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","test_object_en":"Workplace environment – moderate microclimate","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","methodology_en":"PMV index, PPD index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy – mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 — 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a5dc9aaf1c10c8ce825a255","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","test_object_en":"Workplace environment – hot microclimate","methodology":"Temperatura powietrza","methodology_en":"Air temperature","parameters":[{"name":"Zakres","range":"(10 – 60) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(10 – 60) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 60) °C"}],"parameters_en":[{"name":"Range","range":"(10 – 60) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(10 – 60) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 – 60) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 60) °C\nTemperatura wilgotna naturalna\nZakres (10 – 60) °C\nTemperatura poczernionej kuli\nZakres (10 – 60) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (10 – 60) °C\nTemperatura wilgotna naturalna\nZakres (10 – 60) °C\nTemperatura poczernionej kuli\nZakres (10 – 60) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy – mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (10 – 60) °C\nTemperatura wilgotna naturalna\nZakres (10 – 60) °C\nTemperatura poczernionej kuli\nZakres (10 – 60) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 60) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(10 – 60) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 – 60) °C"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a5dc9aaf1c10c8ce825a256","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","test_object_en":"Workplace environment – hot microclimate","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","methodology_en":"WBGT index, WBGTeff index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy – mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a5dc9aaf1c10c8ce825a257","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Ścieki, Wody opadowe, Wody roztopowe","test_object_en":"Wastewater, Rainwater, Snowmelt water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura pobranej próbki ścieków, wód opadowych, wód roztopowych"},{"name":"Zakres","range":"(10,0 – 40,0) oC"}],"parameters_en":[{"name":"Temperature of the collected sample of wastewater, rainwater, snowmelt water"},{"name":"Range","range":"(10,0 – 40,0) oC"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków, wód opadowych, wód roztopowych\nZakres (10,0 – 40,0) oC\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Wody opadowe, Wody roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków, wód opadowych, wód roztopowych\nZakres (10,0 – 40,0) oC\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki, Wody opadowe, Wody roztopowe Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow, wod opadowych, wod roztopowych\nZakres (10,0 – 40,0) oC\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Rainwater, Snowmelt water Sampling for chemical and physical testing Manual method Temperature of the collected sample of wastewater, rainwater, snowmelt water Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"Temperatura pobranej próbki ścieków, wód opadowych, wód roztopowych"},{"name":"范围","range":"(10,0 – 40,0) oC"}],"search_zh":"废水、雨水、融雪水 化学与物理检测用样品采集 手工法 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手工法","test_object_zh":"废水、雨水、融雪水"},{"_id":"6a5dc9aaf1c10c8ce825a258","lab_id":"69ad52a3de79e566650fb9f9","country":"PL","accr_number":"AB 1855","accr_body":"PCA","test_object":"Ścieki, Wody opadowe, Wody roztopowe","test_object_en":"Wastewater, Rainwater, Snowmelt water","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Wody opadowe, Wody roztopowe pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki, Wody opadowe, Wody roztopowe pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Rainwater, Snowmelt water pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"废水、雨水、融雪水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"废水、雨水、融雪水"}],"has_pdf":true}