{"lab":{"_id":"69ad52a3de79e566650fb9f1","accr_number":"AB 1851","country":"PL","accr_body":"PCA","address":"Laboratorium Budowlane LABET, ul. Spokojna 10, 05-532 Baniocha","categories":["construction","water"],"city":"Baniocha","imported_at":"2026-03-08T10:42:43.265Z","methods_count":10,"name":"LABET Sp z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1851.pdf"],"scope_summary":"","search_text":"labet sp z o.o. laboratorium budowlane labet, ul. spokojna 10, 05-532 baniocha construction other water materials food","status":"active","updated_at":"2026-03-08T14:50:58.829Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:58.829Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201851,podmiot.html","fields_of_testing":[{"codes":"J/5/P","pl":"Badania mechaniczne i pobieranie próbek materiałów i wyrobów budowlanych","en":"Mechanical tests and sampling of building materials and products"},{"codes":"N/5/P","pl":"Badania właściwości fizycznych i pobieranie próbek materiałów i wyrobów budowlanych","en":"Tests of physical properties and sampling of building materials and products"},{"codes":"N/5","pl":"Badania właściwości fizycznych wyrobów budowlanych","en":"Tests of physical properties of building products"},{"codes":"N/31","pl":"Badania właściwości fizycznych gruntów","en":"Tests of physical properties of ground"},{"codes":"P/5","pl":"Pobieranie próbek materiałów i wyrobów budowlanych","en":"Sampling of building materials and products"}],"issue":{"no":"3","date":"30.01.2026"},"parse_date":"2026-07-20T07:09:30.548Z","parse_source":"script-pdfplumber","map_coord":[52.012603,21.127465],"map_geo":"nominatim-street","has_en":true,"category_counts":{"construction":8,"other":2,"water":2},"category_scores":{"construction":5.33,"other":0.33,"water":0.33},"has_zh":true},"methods":[{"_id":"6a5dc9aaf1c10c8ce825a1f7","lab_id":"69ad52a3de79e566650fb9f1","country":"PL","accr_number":"AB 1851","accr_body":"PCA","test_object":"Mieszanka betonowa","test_object_en":"Fresh concrete","methodology":"Konsystencja","methodology_en":"Consistency","parameters":[],"parameters_en":[],"technique":"Metoda opadu stożka","techniques":["Metoda opadu stożka"],"technique_en":"Slump test method","computed":[],"computed_en":[],"activity":"Konsystencja\nMetoda opadu stożka","reference":"PN-EN 12350-2:2019-07","norm_bases":["PN-EN 12350-2:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mieszanka betonowa Konsystencja\nMetoda opadu stożka PN-EN 12350-2:2019-07 Mieszanka betonowa Konsystencja\nMetoda opadu stozka PN-EN 12350-2:2019-07","categories":["construction"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fresh concrete Consistency Slump test method PN-EN 12350-2:2019-07","methodology_zh":"稠度","search_zh":"混凝土拌合物 稠度 坍落度法 PN-EN 12350-2:2019-07","technique_zh":"坍落度法","test_object_zh":"混凝土拌合物"},{"_id":"6a5dc9aaf1c10c8ce825a1f8","lab_id":"69ad52a3de79e566650fb9f1","country":"PL","accr_number":"AB 1851","accr_body":"PCA","test_object":"Mieszanka betonowa","test_object_en":"Fresh concrete","methodology":"Pobieranie próbek","methodology_en":"Sampling","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek","reference":"PN-EN 12350-1:2019-07 | PN-EN 12350-1:2019-07/Ap1:2022-06","norm_bases":["PN-EN 12350-1:2019-07","PN-EN 12350-1:2019-07/Ap1:2022-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mieszanka betonowa Pobieranie próbek PN-EN 12350-1:2019-07 | PN-EN 12350-1:2019-07/Ap1:2022-06 Mieszanka betonowa Pobieranie probek PN-EN 12350-1:2019-07 | PN-EN 12350-1:2019-07/Ap1:2022-06","categories":["construction"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Fresh concrete Sampling PN-EN 12350-1:2019-07 | PN-EN 12350-1:2019-07/Ap1:2022-06","methodology_zh":"样品采集","search_zh":"混凝土拌合物 样品采集 PN-EN 12350-1:2019-07 | PN-EN 12350-1:2019-07/Ap1:2022-06","test_object_zh":"混凝土拌合物"},{"_id":"6a5dc9aaf1c10c8ce825a1f9","lab_id":"69ad52a3de79e566650fb9f1","country":"PL","accr_number":"AB 1851","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Głębokość penetracji wody pod ciśnieniem","methodology_en":"Depth of penetration of water under pressure","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Głębokość penetracji wody pod ciśnieniem","reference":"PN-EN 12390-8:2019-08","norm_bases":["PN-EN 12390-8:2019-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Głębokość penetracji wody pod ciśnieniem PN-EN 12390-8:2019-08 Beton Glebokosc penetracji wody pod cisnieniem PN-EN 12390-8:2019-08","categories":["water","construction"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete Depth of penetration of water under pressure PN-EN 12390-8:2019-08","methodology_zh":"压力水渗透深度","search_zh":"混凝土 压力水渗透深度 PN-EN 12390-8:2019-08","test_object_zh":"混凝土"},{"_id":"6a5dc9aaf1c10c8ce825a1fa","lab_id":"69ad52a3de79e566650fb9f1","country":"PL","accr_number":"AB 1851","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Wytrzymałość na ściskanie","methodology_en":"Compressive strength","parameters":[{"name":"Zakres","range":"(100 - 3000) kN"}],"parameters_en":[{"name":"Range","range":"(100 - 3000) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na ściskanie\nZakres (100 - 3000) kN","reference":"PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12390-3:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Wytrzymałość na ściskanie\nZakres (100 - 3000) kN PN-EN 12390-3:2019-07 Beton Wytrzymalosc na sciskanie\nZakres (100 - 3000) kN PN-EN 12390-3:2019-07","categories":["construction"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete Compressive strength Range PN-EN 12390-3:2019-07","methodology_zh":"抗压强度","parameters_zh":[{"name":"范围","range":"(100 - 3000) kN"}],"search_zh":"混凝土 抗压强度 范围 PN-EN 12390-3:2019-07","test_object_zh":"混凝土"},{"_id":"6a5dc9aaf1c10c8ce825a1fb","lab_id":"69ad52a3de79e566650fb9f1","country":"PL","accr_number":"AB 1851","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Nasiąkliwość","methodology_en":"Water absorption","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Nasiąkliwość","reference":"PN-88/B-06250 p. 6.4","norm_bases":["PN-88/B-06250 p. 6.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Nasiąkliwość PN-88/B-06250 p. 6.4 Beton Nasiakliwosc PN-88/B-06250 p. 6.4","categories":["construction"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete Water absorption PN-88/B-06250 p. 6.4","methodology_zh":"吸水率","search_zh":"混凝土 吸水率 PN-88/B-06250 p. 6.4","test_object_zh":"混凝土"},{"_id":"6a5dc9aaf1c10c8ce825a1fc","lab_id":"69ad52a3de79e566650fb9f1","country":"PL","accr_number":"AB 1851","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Przepuszczalność wody","methodology_en":"Water permeability","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność wody","reference":"PN-88/B-06250 p. 6.6","norm_bases":["PN-88/B-06250 p. 6.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Przepuszczalność wody PN-88/B-06250 p. 6.6 Beton Przepuszczalnosc wody PN-88/B-06250 p. 6.6","categories":["water","construction"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete Water permeability PN-88/B-06250 p. 6.6","methodology_zh":"透水性","search_zh":"混凝土 透水性 PN-88/B-06250 p. 6.6","test_object_zh":"混凝土"},{"_id":"6a5dc9aaf1c10c8ce825a1fd","lab_id":"69ad52a3de79e566650fb9f1","country":"PL","accr_number":"AB 1851","accr_body":"PCA","test_object":"Beton","test_object_en":"Concrete","methodology":"Odporność na działanie mrozu","methodology_en":"Resistance to freezing","parameters":[],"parameters_en":[],"technique":"Metoda zwykła","techniques":["Metoda zwykła"],"technique_en":"Ordinary method","computed":[],"computed_en":[],"activity":"Odporność na działanie mrozu\nMetoda zwykła","reference":"PN-B-06265:2022-08 Załącznik N | PN-88/B-06250","norm_bases":["PN-B-06265:2022-08 Załącznik N","PN-88/B-06250"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Beton Odporność na działanie mrozu\nMetoda zwykła PN-B-06265:2022-08 Załącznik N | PN-88/B-06250 Beton Odpornosc na dzialanie mrozu\nMetoda zwykla PN-B-06265:2022-08 Zalacznik N | PN-88/B-06250","categories":["construction"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Concrete Resistance to freezing Ordinary method PN-B-06265:2022-08 Załącznik N | PN-88/B-06250","methodology_zh":"抗冻性","search_zh":"混凝土 抗冻性 常规法 PN-B-06265:2022-08 Załącznik N | PN-88/B-06250","test_object_zh":"混凝土","technique_zh":"常规法"},{"_id":"6a5dc9aaf1c10c8ce825a1fe","lab_id":"69ad52a3de79e566650fb9f1","country":"PL","accr_number":"AB 1851","accr_body":"PCA","test_object":"Prefabrykaty betonowe","test_object_en":"Precast concrete products","methodology":"Nasiąkliwość","methodology_en":"Water absorption","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Nasiąkliwość","reference":"PN-EN 13369:2018-05 Załącznik F","norm_bases":["PN-EN 13369:2018-05 Załącznik F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Prefabrykaty betonowe Nasiąkliwość PN-EN 13369:2018-05 Załącznik F Prefabrykaty betonowe Nasiakliwosc PN-EN 13369:2018-05 Zalacznik F","categories":["construction"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Precast concrete products Water absorption PN-EN 13369:2018-05 Załącznik F","methodology_zh":"吸水率","search_zh":"吸水率 PN-EN 13369:2018-05 Załącznik F"},{"_id":"6a5dc9aaf1c10c8ce825a1ff","lab_id":"69ad52a3de79e566650fb9f1","country":"PL","accr_number":"AB 1851","accr_body":"PCA","test_object":"Podłoże gruntowe","test_object_en":"Subsoil","methodology":"Moduł odkształcenia","methodology_en":"Deformation modulus","parameters":[{"name":"Zakres","range":"(0,02 - 0,45) MPa"}],"parameters_en":[{"name":"Range","range":"(0,02 - 0,45) MPa"}],"technique":"Metoda obciążeń płytą VSS","techniques":["Metoda obciążeń płytą VSS"],"technique_en":"VSS plate loading method","computed":[],"computed_en":[],"activity":"Moduł odkształcenia\nZakres (0,02 - 0,45) MPa\nMetoda obciążeń płytą VSS","reference":"PN-S-02205:1998","norm_bases":["PN-S-02205:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podłoże gruntowe Moduł odkształcenia\nZakres (0,02 - 0,45) MPa\nMetoda obciążeń płytą VSS PN-S-02205:1998 Podloze gruntowe Modul odksztalcenia\nZakres (0,02 - 0,45) MPa\nMetoda obciazen plyta VSS PN-S-02205:1998","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Subsoil Deformation modulus VSS plate loading method Range PN-S-02205:1998","parameters_zh":[{"name":"范围","range":"(0,02 - 0,45) MPa"}],"search_zh":"变形模量 VSS 平板荷载法 范围 PN-S-02205:1998","methodology_zh":"变形模量","technique_zh":"VSS 平板荷载法"},{"_id":"6a5dc9aaf1c10c8ce825a200","lab_id":"69ad52a3de79e566650fb9f1","country":"PL","accr_number":"AB 1851","accr_body":"PCA","test_object":"Podłoże gruntowe","test_object_en":"Subsoil","methodology":"Stopień zagęszczenia","methodology_en":"Degree of compaction","parameters":[{"name":"ID =","range":"(0,33 - 1,03)"},{"name":"DPL"}],"parameters_en":[{"name":"ID =","range":"(0,33 - 1,03)"},{"name":"DPL"}],"technique":"Metoda sondą dynamiczną lekką","techniques":["Metoda sondą dynamiczną lekką"],"technique_en":"Light dynamic probe method","computed":[],"computed_en":[],"activity":"Stopień zagęszczenia\nZakres:\nID = (0,33 - 1,03)\nDPL\nMetoda sondą dynamiczną lekką","reference":"PN-B-04452:2002 Warunki techniczne utrzymania podtorza kolejowego Id–3 (zał. 2 do Zarządzenia nr 9/2009 Zarządu PKP PLK S.A. z dnia 04.05.2009 r.)","norm_bases":["PN-B-04452:2002 Warunki techniczne utrzymania podtorza kolejowego Id–3 (zał. 2 do Zarządzenia nr 9/2009 Zarządu PKP PLK S.A. z dnia 04.05.2009 r.)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podłoże gruntowe Stopień zagęszczenia\nZakres:\nID = (0,33 - 1,03)\nDPL\nMetoda sondą dynamiczną lekką PN-B-04452:2002 Warunki techniczne utrzymania podtorza kolejowego Id–3 (zał. 2 do Zarządzenia nr 9/2009 Zarządu PKP PLK S.A. z dnia 04.05.2009 r.) Podloze gruntowe Stopien zageszczenia\nZakres:\nID = (0,33 - 1,03)\nDPL\nMetoda sonda dynamiczna lekka PN-B-04452:2002 Warunki techniczne utrzymania podtorza kolejowego Id–3 (zal. 2 do Zarzadzenia nr 9/2009 Zarzadu PKP PLK S.A. z dnia 04.05.2009 r.)","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Subsoil Degree of compaction Light dynamic probe method ID = DPL PN-B-04452:2002 Warunki techniczne utrzymania podtorza kolejowego Id–3 (zał. 2 do Zarządzenia nr 9/2009 Zarządu PKP PLK S.A. z dnia 04.05.2009 r.)","methodology_zh":"密实度","search_zh":"密实度 PN-B-04452:2002 Warunki techniczne utrzymania podtorza kolejowego Id–3 (zał. 2 do Zarządzenia nr 9/2009 Zarządu PKP PLK S.A. z dnia 04.05.2009 r.)"}],"has_pdf":true}