{"lab":{"_id":"69ad52a3de79e566650fb9ef","accr_number":"AB 1850","country":"PL","accr_body":"PCA","address":"w Wyszkowie, ul. Komunalna 1, 07-200 Wyszków, DZIAŁ LABORATORIUM, ul. Komunalna 12","categories":["water","microbiology"],"city":"Wyszków","imported_at":"2026-03-08T10:42:43.265Z","methods_count":18,"name":"PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1850.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo wodociągów i kanalizacji sp. z o.o. w wyszkowie, ul. komunalna 1, 07-200 wyszków, dział laboratorium, ul. komunalna 12 water microbiology other pharma electronics","status":"active","updated_at":"2026-03-08T14:50:58.776Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:58.776Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201850,podmiot.html","fields_of_testing":[{"codes":"C/29/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Chemical tests and sampling of drinking water"},{"codes":"N/29/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi","en":"Tests of physical properties and sampling of drinking water"},{"codes":"K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests and sampling of drinking water"}],"issue":{"no":"4","date":"07.10.2025"},"parse_date":"2026-07-20T07:09:30.525Z","parse_source":"script-pdfplumber","map_coord":[52.609749,21.454817],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":18,"microbiology":3},"category_scores":{"water":15.43,"microbiology":0.43},"has_zh":true},"methods":[{"_id":"6a5dc9aaf1c10c8ce825a1e5","lab_id":"69ad52a3de79e566650fb9ef","country":"PL","accr_number":"AB 1850","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a1e6","lab_id":"69ad52a3de79e566650fb9ef","country":"PL","accr_number":"AB 1850","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a1e7","lab_id":"69ad52a3de79e566650fb9ef","country":"PL","accr_number":"AB 1850","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","methodology_en":"Most probable number, Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda NPL (Test Colilert 18)","techniques":["Metoda NPL (Test Colilert 18)"],"technique_en":"MPN method (Colilert 18 Test)","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL (Test Colilert 18)","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL (Test Colilert 18) PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL (Test Colilert 18) PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Most probable number, Escherichia coli MPN method (Colilert 18 Test) PN-EN ISO 9308-2:2014-06","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）最可能数（MPN） MPN 法（Colilert 18 测试） PN-EN ISO 9308-2:2014-06","test_object_zh":"生活饮用水","technique_zh":"MPN 法（Colilert 18 测试）"},{"_id":"6a5dc9aaf1c10c8ce825a1e8","lab_id":"69ad52a3de79e566650fb9ef","country":"PL","accr_number":"AB 1850","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","methodology_en":"Most probable number of coliform bacteria","parameters":[],"parameters_en":[],"technique":"Metoda NPL (Test Colilert 18)","techniques":["Metoda NPL (Test Colilert 18)"],"technique_en":"MPN method (Colilert 18 Test)","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL (Test Colilert 18)","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL (Test Colilert 18) PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL (Test Colilert 18) PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Most probable number of coliform bacteria MPN method (Colilert 18 Test) PN-EN ISO 9308-2:2014-06","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"生活饮用水 大肠菌群最可能数（MPN） MPN 法（Colilert 18 测试） PN-EN ISO 9308-2:2014-06","test_object_zh":"生活饮用水","technique_zh":"MPN 法（Colilert 18 测试）"},{"_id":"6a5dc9aaf1c10c8ce825a1e9","lab_id":"69ad52a3de79e566650fb9ef","country":"PL","accr_number":"AB 1850","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Najbardziej prawdopodobna liczba enterokoków","methodology_en":"Most probable number of enterococci","parameters":[],"parameters_en":[],"technique":"Metoda NPL (Test Enterolert DW)","techniques":["Metoda NPL (Test Enterolert DW)"],"technique_en":"MPN method (Enterolert DW test)","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba enterokoków\nMetoda NPL (Test Enterolert DW)","reference":"Instrukcja producenta testu Enterolert-DW firmy IDEXX wyd. 06-18085-10 z 2025 r.","norm_bases":["Instrukcja producenta testu Enterolert-DW firmy IDEXX wyd. 06-18085-10 z 2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba enterokoków\nMetoda NPL (Test Enterolert DW) Instrukcja producenta testu Enterolert-DW firmy IDEXX wyd. 06-18085-10 z 2025 r. Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba enterokokow\nMetoda NPL (Test Enterolert DW) Instrukcja producenta testu Enterolert-DW firmy IDEXX wyd. 06-18085-10 z 2025 r.","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Most probable number of enterococci MPN method (Enterolert DW test) Instrukcja producenta testu Enterolert-DW firmy IDEXX wyd. 06-18085-10 z 2025 r.","search_zh":"生活饮用水 肠球菌最可能数 Instrukcja producenta testu Enterolert-DW firmy IDEXX wyd. 06-18085-10 z 2025 r.","test_object_zh":"生活饮用水","methodology_zh":"肠球菌最可能数"},{"_id":"6a5dc9aaf1c10c8ce825a1ea","lab_id":"69ad52a3de79e566650fb9ef","country":"PL","accr_number":"AB 1850","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(4 - 100) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(4 - 100) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (4 - 100) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 p.6 +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 p.6 +Ap1:2015-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (4 - 100) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 p.6 +Ap1:2015-06 Woda do spozycia przez ludzi Barwa\nZakres (4 - 100) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 p.6 +Ap1:2015-06","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012 p.6 +Ap1:2015-06","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(4 - 100) mg/l Pt"}],"search_zh":"生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 p.6 +Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a1eb","lab_id":"69ad52a3de79e566650fb9ef","country":"PL","accr_number":"AB 1850","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,20 - 50) NTU"}],"parameters_en":[{"name":"Range","range":"(0,20 - 50) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,20 - 50) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,20 - 50) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,20 - 50) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 - 50) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a1ec","lab_id":"69ad52a3de79e566650fb9ef","country":"PL","accr_number":"AB 1850","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 - 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 - 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 - 10,0"}],"search_zh":"生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a1ed","lab_id":"69ad52a3de79e566650fb9ef","country":"PL","accr_number":"AB 1850","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(0,020 - 10) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,020 - 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,020 - 10) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 p. 7.1.1 +Ap.1:2016-06","norm_bases":["PN-ISO 6332:2001 p. 7.1.1 +Ap.1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (0,020 - 10) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 p. 7.1.1 +Ap.1:2016-06 Woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (0,020 - 10) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 p. 7.1.1 +Ap.1:2016-06","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001 p. 7.1.1 +Ap.1:2016-06","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,020 - 10) mg/l"}],"search_zh":"生活饮用水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001 p. 7.1.1 +Ap.1:2016-06","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a1ee","lab_id":"69ad52a3de79e566650fb9ef","country":"PL","accr_number":"AB 1850","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(10 - 450) μg/l"}],"parameters_en":[{"name":"Range","range":"(10 - 450) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (10 - 450) μg/l\nMetoda spektrofotometryczna","reference":"Instrukcja producenta testu NANOCOLOR Mangan LR, nr kat. 918126, firmy Macherey-Nagel z 01.2023 r.","norm_bases":["Instrukcja producenta testu NANOCOLOR Mangan LR, nr kat. 918126, firmy Macherey-Nagel z 01.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (10 - 450) μg/l\nMetoda spektrofotometryczna Instrukcja producenta testu NANOCOLOR Mangan LR, nr kat. 918126, firmy Macherey-Nagel z 01.2023 r. Woda do spozycia przez ludzi Stezenie manganu\nZakres (10 - 450) μg/l\nMetoda spektrofotometryczna Instrukcja producenta testu NANOCOLOR Mangan LR, nr kat. 918126, firmy Macherey-Nagel z 01.2023 r.","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Manganese concentration Spectrophotometric method Range Instrukcja producenta testu NANOCOLOR Mangan LR, nr kat. 918126, firmy Macherey-Nagel z 01.2023 r.","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(10 - 450) μg/l"}],"search_zh":"生活饮用水 锰浓度 分光光度法 范围 Instrukcja producenta testu NANOCOLOR Mangan LR, nr kat. 918126, firmy Macherey-Nagel z 01.2023 r.","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a1ef","lab_id":"69ad52a3de79e566650fb9ef","country":"PL","accr_number":"AB 1850","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters":[{"name":"Zakres","range":"(20 - 600) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(20 - 600) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (20 - 600) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (20 - 600) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (20 - 600) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(20 - 600) mg/l CaCO3"}],"search_zh":"生活饮用水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a1f0","lab_id":"69ad52a3de79e566650fb9ef","country":"PL","accr_number":"AB 1850","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie jonu amonowego","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,040-2,50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,040-2,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego\nZakres (0,040-2,50) mg/l\nMetoda spektrofotometryczna","reference":"Instrukcja producenta testu LCK 304 firmy HACH wyd. 1 z 10.2019 r.","norm_bases":["Instrukcja producenta testu LCK 304 firmy HACH wyd. 1 z 10.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,040-2,50) mg/l\nMetoda spektrofotometryczna Instrukcja producenta testu LCK 304 firmy HACH wyd. 1 z 10.2019 r. Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,040-2,50) mg/l\nMetoda spektrofotometryczna Instrukcja producenta testu LCK 304 firmy HACH wyd. 1 z 10.2019 r.","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Ammonium ion concentration Spectrophotometric method Range Instrukcja producenta testu LCK 304 firmy HACH wyd. 1 z 10.2019 r.","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,040-2,50) mg/l"}],"search_zh":"生活饮用水 铵离子浓度 分光光度法 范围 Instrukcja producenta testu LCK 304 firmy HACH wyd. 1 z 10.2019 r.","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a1f1","lab_id":"69ad52a3de79e566650fb9ef","country":"PL","accr_number":"AB 1850","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(0,177 - 221) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,177 - 221) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres (0,177 - 221) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576-08","norm_bases":["PN-82/C-04576-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,177 - 221) mg/l\nMetoda spektrofotometryczna PN-82/C-04576-08 Woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,177 - 221) mg/l\nMetoda spektrofotometryczna PN-82/C-04576-08","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Nitrate concentration Spectrophotometric method Range PN-82/C-04576-08","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,177 - 221) mg/l"}],"search_zh":"生活饮用水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576-08","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a1f2","lab_id":"69ad52a3de79e566650fb9ef","country":"PL","accr_number":"AB 1850","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie azotynów","methodology_en":"Nitrite concentration","parameters":[{"name":"Zakres","range":"(0,010 - 16) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,010 - 16) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotynów\nZakres (0,010 - 16) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,010 - 16) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,010 - 16) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,010 - 16) mg/l"}],"search_zh":"生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a1f3","lab_id":"69ad52a3de79e566650fb9ef","country":"PL","accr_number":"AB 1850","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5 - 400) mg/l"}],"parameters_en":[{"name":"Range","range":"(5 - 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5 - 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie chlorków\nZakres (5 - 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5 - 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 - 400) mg/l"}],"search_zh":"生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a1f4","lab_id":"69ad52a3de79e566650fb9ef","country":"PL","accr_number":"AB 1850","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(147-2770) μS/cm"}],"parameters_en":[{"name":"Range","range":"(147-2770) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (147-2770) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (147-2770) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (147-2770) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(147-2770) μS/cm"}],"search_zh":"生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a1f5","lab_id":"69ad52a3de79e566650fb9ef","country":"PL","accr_number":"AB 1850","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie jonu amonowego","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,050 - 10,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,050 - 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego\nZakres (0,050 - 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,050 - 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,050 - 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,050 - 10,0) mg/l"}],"search_zh":"生活饮用水 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9aaf1c10c8ce825a1f6","lab_id":"69ad52a3de79e566650fb9ef","country":"PL","accr_number":"AB 1850","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Utlenialność (Indeks nadmanganianowy)","methodology_en":"Oxidability (Permanganate index)","parameters":[{"name":"Zakres","range":"(0,50 - 10,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,50 - 10,0) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Utlenialność (Indeks nadmanganianowy)\nZakres (0,50 - 10,0) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Utlenialność (Indeks nadmanganianowy)\nZakres (0,50 - 10,0) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda do spozycia przez ludzi Utlenialnosc (Indeks nadmanganianowy)\nZakres (0,50 - 10,0) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Oxidability (Permanganate index) Titrimetric method Range PN-EN ISO 8467:2001","parameters_zh":[{"name":"范围","range":"(0,50 - 10,0) mg/l O2"}],"search_zh":"生活饮用水 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"生活饮用水"}],"has_pdf":true}