{"lab":{"_id":"69ad52a3de79e566650fb9d7","accr_number":"AB 1832","country":"PL","accr_body":"PCA","address":"- PAŃSTWOWY INSTYTUT BADAWCZY ODDZIAŁ SOŚNICOWICE, LABORATORIUM BADANIA JAKOŚCI ŚRODKÓW OCHRONY ROŚLIN, ul. Gliwicka 29","categories":["other"],"city":"Sośnicowice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":11,"name":"INSTYTUT OCHRONY ROŚLIN","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1832.pdf"],"scope_summary":"","search_text":"instytut ochrony roślin - państwowy instytut badawczy oddział sośnicowice, laboratorium badania jakości środków ochrony roślin, ul. gliwicka 29 other metrology food","status":"active","updated_at":"2026-03-08T14:50:58.000Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T15:13:42.949Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201832,podmiot.html","fields_of_testing":[{"codes":"C/56","pl":"Badania chemiczne środków ochrony roślin","en":"Chemical tests of plant protection products"},{"codes":"N/56","pl":"Badania właściwości fizycznych środków ochrony roślin","en":"Tests of physical properties of plant protection products"}],"issue":{"no":"7","date":"09.04.2026"},"parse_date":"2026-08-17T15:13:42.949Z","parse_source":"agent-claude-code","map_coord":[50.27029,18.541051],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BADANIA JAKOŚCI ŚRODKÓW OCHRONY ROŚLIN","address":"ul. Gliwicka 29","city":"Sośnicowice","postal":"44-153"}],"scope_format":"PCA::pracownie+elastyczny+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/db90c1fca6060b0e806cfcbf2b2fea32/AB%201832.pdf","has_en":true,"category_counts":{"other":11},"category_scores":{"other":11},"has_zh":true},"methods":[{"_id":"6a832526884ede9a1b2c4ff7","lab_id":"69ad52a3de79e566650fb9d7","country":"PL","accr_number":"AB 1832","accr_body":"PCA","test_object":"Środki ochrony roślin","methodology":"Gęstość","parameters":[{"name":"Zakres","range":"(0,8 - 1,5) g/ml"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość\nZakres (0,8 - 1,5) g/ml\nMetoda oscylacyjna","reference":"PB-04 wyd.1 z dnia 23.09.2021","norm_bases":["PB-04 wyd.1 z dnia 23.09.2021"],"lab_section":"Laboratorium Badania Jakości Środków Ochrony Roślin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki ochrony roślin Gęstość\nZakres (0,8 - 1,5) g/ml\nMetoda oscylacyjna PB-04 wyd.1 z dnia 23.09.2021 Srodki ochrony roslin Gestosc\nZakres (0,8 - 1,5) g/ml\nMetoda oscylacyjna PB-04 wyd.1 z dnia 23.09.2021","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density","parameters_en":[{"name":"Range","range":"(0,8 - 1,5) g/ml"}],"search_en":"Plant protection products Density Oscillation method Range PB-04 wyd.1 z dnia 23.09.2021","technique_en":"Oscillation method","test_object_en":"Plant protection products","methodology_zh":"密度","parameters_zh":[{"name":"范围","range":"(0,8 - 1,5) g/ml"}],"search_zh":"植物保护产品 密度 振荡法 范围 PB-04 wyd.1 z dnia 23.09.2021","technique_zh":"振荡法","test_object_zh":"植物保护产品"},{"_id":"6a832526884ede9a1b2c4ff8","lab_id":"69ad52a3de79e566650fb9d7","country":"PL","accr_number":"AB 1832","accr_body":"PCA","test_object":"Środki ochrony roślin","methodology":"pH","parameters":[{"name":"Zakres","range":"(2 - 12)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (2 - 12)\nMetoda potencjometryczna","reference":"PB-02 wyd.3 z dnia 27.02.2023","norm_bases":["PB-02 wyd.3 z dnia 27.02.2023"],"lab_section":"Laboratorium Badania Jakości Środków Ochrony Roślin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki ochrony roślin pH\nZakres (2 - 12)\nMetoda potencjometryczna PB-02 wyd.3 z dnia 27.02.2023 Srodki ochrony roslin pH\nZakres (2 - 12)\nMetoda potencjometryczna PB-02 wyd.3 z dnia 27.02.2023","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(2 - 12)"}],"search_en":"Plant protection products pH Potentiometric method Range PB-02 wyd.3 z dnia 27.02.2023","technique_en":"Potentiometric method","test_object_en":"Plant protection products","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(2 - 12)"}],"search_zh":"植物保护产品 pH 值 电位法 范围 PB-02 wyd.3 z dnia 27.02.2023","technique_zh":"电位法","test_object_zh":"植物保护产品"},{"_id":"6a832526884ede9a1b2c4ff9","lab_id":"69ad52a3de79e566650fb9d7","country":"PL","accr_number":"AB 1832","accr_body":"PCA","test_object":"Środki ochrony roślin","methodology":"Pozostałość na sicie mokrym o wymiarze oczek 0,075 mm","parameters":[{"name":"Zakres","range":"(0,1 – 15)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Pozostałość na sicie mokrym o wymiarze oczek 0,075 mm\nZakres (0,1 – 15)%\nMetoda wagowa","reference":"PB-06 wyd.2 z dnia 16.12.2025","norm_bases":["PB-06 wyd.2 z dnia 16.12.2025"],"lab_section":"Laboratorium Badania Jakości Środków Ochrony Roślin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki ochrony roślin Pozostałość na sicie mokrym o wymiarze oczek 0,075 mm\nZakres (0,1 – 15)%\nMetoda wagowa PB-06 wyd.2 z dnia 16.12.2025 Srodki ochrony roslin Pozostalosc na sicie mokrym o wymiarze oczek 0,075 mm\nZakres (0,1 – 15)%\nMetoda wagowa PB-06 wyd.2 z dnia 16.12.2025","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Residue on a wet sieve with 0,075 mm mesh","parameters_en":[{"name":"Range","range":"(0,1 – 15)%"}],"search_en":"Plant protection products Residue on a wet sieve with 0,075 mm mesh Gravimetric method Range PB-06 wyd.2 z dnia 16.12.2025","technique_en":"Gravimetric method","test_object_en":"Plant protection products","parameters_zh":[{"name":"范围","range":"(0,1 – 15)%"}],"search_zh":"植物保护产品 重量法 范围 PB-06 wyd.2 z dnia 16.12.2025","technique_zh":"重量法","test_object_zh":"植物保护产品"},{"_id":"6a832526884ede9a1b2c4ffa","lab_id":"69ad52a3de79e566650fb9d7","country":"PL","accr_number":"AB 1832","accr_body":"PCA","test_object":"Środki ochrony roślin","methodology":"Trwałość piany","parameters":[{"name":"Zakres","range":"(0 - 70) ml"}],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Trwałość piany\nZakres (0 - 70) ml\nMetoda objętościowa","reference":"PB-05 wyd.1 z dnia 19.07.2021","norm_bases":["PB-05 wyd.1 z dnia 19.07.2021"],"lab_section":"Laboratorium Badania Jakości Środków Ochrony Roślin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki ochrony roślin Trwałość piany\nZakres (0 - 70) ml\nMetoda objętościowa PB-05 wyd.1 z dnia 19.07.2021 Srodki ochrony roslin Trwalosc piany\nZakres (0 - 70) ml\nMetoda objetosciowa PB-05 wyd.1 z dnia 19.07.2021","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Foam stability","parameters_en":[{"name":"Range","range":"(0 - 70) ml"}],"search_en":"Plant protection products Foam stability Volumetric method Range PB-05 wyd.1 z dnia 19.07.2021","technique_en":"Volumetric method","test_object_en":"Plant protection products","parameters_zh":[{"name":"范围","range":"(0 - 70) ml"}],"search_zh":"植物保护产品 容量法 范围 PB-05 wyd.1 z dnia 19.07.2021","technique_zh":"容量法","test_object_zh":"植物保护产品"},{"_id":"6a832526884ede9a1b2c4ffb","lab_id":"69ad52a3de79e566650fb9d7","country":"PL","accr_number":"AB 1832","accr_body":"PCA","test_object":"Środki ochrony roślin","methodology":"Zawartość/stężenie czterochlorku węgla","parameters":[{"name":"Zakres","range":"(0,02 – 1,40) g/kg"},{"name":"Zakres","range":"(0,02 – 2,10) g/l"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Zawartość/stężenie czterochlorku węgla\nZakres:\nZakres (0,02 – 1,40) g/kg\nZakres (0,02 – 2,10) g/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PB-21 wyd.2 z dnia 16.12.2025","norm_bases":["PB-21 wyd.2 z dnia 16.12.2025"],"lab_section":"Laboratorium Badania Jakości Środków Ochrony Roślin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki ochrony roślin Zawartość/stężenie czterochlorku węgla\nZakres:\nZakres (0,02 – 1,40) g/kg\nZakres (0,02 – 2,10) g/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PB-21 wyd.2 z dnia 16.12.2025 Srodki ochrony roslin Zawartosc/stezenie czterochlorku wegla\nZakres:\nZakres (0,02 – 1,40) g/kg\nZakres (0,02 – 2,10) g/l\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PB-21 wyd.2 z dnia 16.12.2025","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content/concentration of carbon tetrachloride","parameters_en":[{"name":"Range","range":"(0,02 – 1,40) g/kg"},{"name":"Range","range":"(0,02 – 2,10) g/l"}],"search_en":"Plant protection products Content/concentration of carbon tetrachloride Gas chromatography with electron capture detection (GC-ECD) Range Range PB-21 wyd.2 z dnia 16.12.2025","technique_en":"Gas chromatography with electron capture detection (GC-ECD)","test_object_en":"Plant protection products","parameters_zh":[{"name":"范围","range":"(0,02 – 1,40) g/kg"},{"name":"范围","range":"(0,02 – 2,10) g/l"}],"search_zh":"植物保护产品 气相色谱-电子捕获检测法（GC-ECD） 范围 范围 PB-21 wyd.2 z dnia 16.12.2025","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"植物保护产品"},{"_id":"6a832526884ede9a1b2c4ffc","lab_id":"69ad52a3de79e566650fb9d7","country":"PL","accr_number":"AB 1832","accr_body":"PCA","test_object":"Środki ochrony roślin","methodology":"Zawartość/stężenie toluenu","parameters":[{"name":"Zakres","range":"(0,02 – 2,80) g/kg"},{"name":"Zakres","range":"(0,02 – 4,20) g/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość/stężenie toluenu\nZakres:\nZakres (0,02 – 2,80) g/kg\nZakres (0,02 – 4,20) g/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-21 wyd.2 z dnia 16.12.2025","norm_bases":["PB-21 wyd.2 z dnia 16.12.2025"],"lab_section":"Laboratorium Badania Jakości Środków Ochrony Roślin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki ochrony roślin Zawartość/stężenie toluenu\nZakres:\nZakres (0,02 – 2,80) g/kg\nZakres (0,02 – 4,20) g/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-21 wyd.2 z dnia 16.12.2025 Srodki ochrony roslin Zawartosc/stezenie toluenu\nZakres:\nZakres (0,02 – 2,80) g/kg\nZakres (0,02 – 4,20) g/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-21 wyd.2 z dnia 16.12.2025","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content/concentration of toluene","parameters_en":[{"name":"Range","range":"(0,02 – 2,80) g/kg"},{"name":"Range","range":"(0,02 – 4,20) g/l"}],"search_en":"Plant protection products Content/concentration of toluene Gas chromatography with flame ionization detection (GC-FID) Range Range PB-21 wyd.2 z dnia 16.12.2025","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Plant protection products","parameters_zh":[{"name":"范围","range":"(0,02 – 2,80) g/kg"},{"name":"范围","range":"(0,02 – 4,20) g/l"}],"search_zh":"植物保护产品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PB-21 wyd.2 z dnia 16.12.2025","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"植物保护产品"},{"_id":"6a832526884ede9a1b2c4ffd","lab_id":"69ad52a3de79e566650fb9d7","country":"PL","accr_number":"AB 1832","accr_body":"PCA","test_object":"Środki ochrony roślin","methodology":"Kwasowość/zasadowość","parameters":[{"name":"Zakres","range":"(0,02 – 29) %"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Kwasowość/zasadowość\nZakres (0,02 – 29) %\nMetoda miareczkowania potencjometrycznego","reference":"PB-08 wyd.3 z dnia 27.02.2023","norm_bases":["PB-08 wyd.3 z dnia 27.02.2023"],"lab_section":"Laboratorium Badania Jakości Środków Ochrony Roślin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki ochrony roślin Kwasowość/zasadowość\nZakres (0,02 – 29) %\nMetoda miareczkowania potencjometrycznego PB-08 wyd.3 z dnia 27.02.2023 Srodki ochrony roslin Kwasowosc/zasadowosc\nZakres (0,02 – 29) %\nMetoda miareczkowania potencjometrycznego PB-08 wyd.3 z dnia 27.02.2023","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acidity/alkalinity","parameters_en":[{"name":"Range","range":"(0,02 – 29) %"}],"search_en":"Plant protection products Acidity/alkalinity Potentiometric titration method Range PB-08 wyd.3 z dnia 27.02.2023","technique_en":"Potentiometric titration method","test_object_en":"Plant protection products","parameters_zh":[{"name":"范围","range":"(0,02 – 29) %"}],"search_zh":"植物保护产品 电位滴定法 范围 PB-08 wyd.3 z dnia 27.02.2023","technique_zh":"电位滴定法","test_object_zh":"植物保护产品"},{"_id":"6a832526884ede9a1b2c4ffe","lab_id":"69ad52a3de79e566650fb9d7","country":"PL","accr_number":"AB 1832","accr_body":"PCA","test_object":"Środki ochrony roślin","methodology":"Zawieszalność","parameters":[{"name":"Zakres","range":"(29 – 109) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawieszalność\nZakres (29 – 109) %\nMetoda wagowa","reference":"PB-07 wyd.2 z dnia 23.01.2023","norm_bases":["PB-07 wyd.2 z dnia 23.01.2023"],"lab_section":"Laboratorium Badania Jakości Środków Ochrony Roślin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki ochrony roślin Zawieszalność\nZakres (29 – 109) %\nMetoda wagowa PB-07 wyd.2 z dnia 23.01.2023 Srodki ochrony roslin Zawieszalnosc\nZakres (29 – 109) %\nMetoda wagowa PB-07 wyd.2 z dnia 23.01.2023","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Suspensibility","parameters_en":[{"name":"Range","range":"(29 – 109) %"}],"search_en":"Plant protection products Suspensibility Gravimetric method Range PB-07 wyd.2 z dnia 23.01.2023","technique_en":"Gravimetric method","test_object_en":"Plant protection products","parameters_zh":[{"name":"范围","range":"(29 – 109) %"}],"search_zh":"植物保护产品 重量法 范围 PB-07 wyd.2 z dnia 23.01.2023","technique_zh":"重量法","test_object_zh":"植物保护产品"},{"_id":"6a832526884ede9a1b2c4fff","lab_id":"69ad52a3de79e566650fb9d7","country":"PL","accr_number":"AB 1832","accr_body":"PCA","test_object":"Środki ochrony roślin","methodology":"Zwilżalność","parameters":[{"name":"Zakres","range":"(1 - 110) s"}],"technique":"Metoda pomiaru czasu","techniques":["Metoda pomiaru czasu"],"computed":[],"activity":"Zwilżalność\nZakres (1 - 110) s\nMetoda pomiaru czasu","reference":"PB-10 wyd.1 z dnia 23.09.2021","norm_bases":["PB-10 wyd.1 z dnia 23.09.2021"],"lab_section":"Laboratorium Badania Jakości Środków Ochrony Roślin","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środki ochrony roślin Zwilżalność\nZakres (1 - 110) s\nMetoda pomiaru czasu PB-10 wyd.1 z dnia 23.09.2021 Srodki ochrony roslin Zwilzalnosc\nZakres (1 - 110) s\nMetoda pomiaru czasu PB-10 wyd.1 z dnia 23.09.2021","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Wettability","parameters_en":[{"name":"Range","range":"(1 - 110) s"}],"search_en":"Plant protection products Wettability Time measurement method Range PB-10 wyd.1 z dnia 23.09.2021","technique_en":"Time measurement method","test_object_en":"Plant protection products","parameters_zh":[{"name":"范围","range":"(1 - 110) s"}],"search_zh":"植物保护产品 范围 PB-10 wyd.1 z dnia 23.09.2021","test_object_zh":"植物保护产品"},{"_id":"6a832526884ede9a1b2c5000","lab_id":"69ad52a3de79e566650fb9d7","country":"PL","accr_number":"AB 1832","accr_body":"PCA","test_object":"Środki ochrony roślin E","methodology":"Zawartość/stężenie substancji czynnych oraz innych składników środków ochrony roślin","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość/stężenie substancji czynnych oraz innych składników środków ochrony roślin\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-01 wyd.3 z dnia 16.12.2025","norm_bases":["PB-01 wyd.3 z dnia 16.12.2025"],"lab_section":"Laboratorium Badania Jakości Środków Ochrony Roślin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środki ochrony roślin E Zawartość/stężenie substancji czynnych oraz innych składników środków ochrony roślin\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-01 wyd.3 z dnia 16.12.2025 Srodki ochrony roslin E Zawartosc/stezenie substancji czynnych oraz innych skladnikow srodkow ochrony roslin\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-01 wyd.3 z dnia 16.12.2025","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content/concentration of active substances and other components of plant protection products","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Plant protection products E Content/concentration of active substances and other components of plant protection products Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. PB-01 wyd.3 z dnia 16.12.2025","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Plant protection products E","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 PB-01 wyd.3 z dnia 16.12.2025","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a832526884ede9a1b2c5001","lab_id":"69ad52a3de79e566650fb9d7","country":"PL","accr_number":"AB 1832","accr_body":"PCA","test_object":"Środki ochrony roślin E","methodology":"Zawartość/stężenie substancji czynnych oraz innych składników środków ochrony roślin","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-DAD)"],"computed":[],"activity":"Zawartość/stężenie substancji czynnych oraz innych składników środków ochrony roślin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-DAD)","reference":"PB-29 wyd.4 z dnia 16.12.2025","norm_bases":["PB-29 wyd.4 z dnia 16.12.2025"],"lab_section":"Laboratorium Badania Jakości Środków Ochrony Roślin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Środki ochrony roślin E Zawartość/stężenie substancji czynnych oraz innych składników środków ochrony roślin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-DAD) PB-29 wyd.4 z dnia 16.12.2025 Srodki ochrony roslin E Zawartosc/stezenie substancji czynnych oraz innych skladnikow srodkow ochrony roslin\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-DAD) PB-29 wyd.4 z dnia 16.12.2025","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content/concentration of active substances and other components of plant protection products","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body.","search_en":"Plant protection products E Content/concentration of active substances and other components of plant protection products High-performance liquid chromatography with spectrophotometric detection (HPLC-DAD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. PB-29 wyd.4 z dnia 16.12.2025","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-DAD)","test_object_en":"Plant protection products E","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。","search_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供。 PB-29 wyd.4 z dnia 16.12.2025"}],"has_pdf":true}