{"lab":{"_id":"69ad52a3de79e566650fb9b3","accr_number":"AB 1814","country":"PL","accr_body":"PCA","address":"LABORATORIUM WIODĄCE INŻYNIERII PRODUKTU, ul. Oławska 10, Wierzbice, AB xxx, 55-040 Kobierzyce","categories":["construction"],"city":"Kobierzyce","imported_at":"2026-03-08T10:42:43.265Z","methods_count":29,"name":"LEONI KABEL POLSKA SP. Z O.O.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1814.pdf"],"scope_summary":"","search_text":"leoni kabel polska sp. z o.o. laboratorium wiodące inżynierii produktu, ul. oławska 10, wierzbice, ab xxx, 55-040 kobierzyce other construction metrology environment","status":"active","updated_at":"2026-03-08T14:50:57.015Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:57.015Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201814,podmiot.html","fields_of_testing":[{"codes":"E/6","pl":"Badania elektryczne i elektroniczne wyrobów i wyposażenia elektrycznego","en":"Electric and electronic tests of electrical products and equipment"},{"codes":"N/6","pl":"Badania właściwości fizycznych wyrobów i wyposażenia elektrycznego","en":"Test of physical properties of electrical products and equipment"},{"codes":"J/6","pl":"Badania mechaniczne wyrobów i wyposażenia elektrycznego","en":"Mechanical test of electrical products and equipment"},{"codes":"J/21","pl":"Badania mechaniczne wyrobów z tworzyw sztucznych i gumy","en":"Mechanical tests of polymers and rubber products"}],"issue":{"no":"5","date":"01.12.2025"},"parse_date":"2026-07-20T07:09:30.077Z","parse_source":"script-pdfplumber","map_coord":[50.996666,16.983271],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":18,"construction":10,"environment":1},"category_scores":{"other":11.17,"construction":3.45,"environment":0.03},"has_zh":true},"methods":[{"_id":"6a5dc9aaf1c10c8ce825a0e5","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Średnica zewnętrzna kabla/ powłoki","methodology_en":"External diameter of the cable/ sheath","parameters":[{"name":"Zakres","range":"(0,01 - 25) mm"},{"name":"Cable outside diameter"},{"name":"Range","range":"(0,01 - 25) mm"}],"parameters_en":[{"name":"Range","range":"(0,01 - 25) mm"},{"name":"Cable outside diameter"},{"name":"Range","range":"(0,01 - 25) mm"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Średnica zewnętrzna kabla/ powłoki\nZakres:\nZakres (0,01 - 25) mm\nCable outside diameter\nRange (0,01 - 25) mm","reference":"ISO 6722-1:2011 + Cor.1:2012 (p. 5.1) | ISO 6722-2:2013 (p.5.1) | ISO 19642-2:2023-08 (p. 5.2.1, 6.2.1) | ISO 19642-3:2019-01 (p. 5.2.1) | ISO 19642-4:2019-01 (p. 5.2.1) | ISO 19642-5:2019-01 (p. 5.2.1) | ISO 19642-6:2019-01 (p. 5.2.1) | ISO 19642-7:2019-01 (p. 6.2.1) | ISO 19642-8:2019-01 (p. 6.2.1) | ISO 19642-9:2019-01 (p. 6.2.1) | ISO 19642-10:2019-01 (p. 6.2.1) | IEC 60811-203:2012-03 DIN/TS 70112-1:2024-03 (p. 7.4.2)","norm_bases":["ISO 6722-1:2011 + Cor.1:2012 (p. 5.1)","ISO 6722-2:2013 (p.5.1)","ISO 19642-2:2023-08 (p. 5.2.1, 6.2.1)","ISO 19642-3:2019-01 (p. 5.2.1)","ISO 19642-4:2019-01 (p. 5.2.1)","ISO 19642-5:2019-01 (p. 5.2.1)","ISO 19642-6:2019-01 (p. 5.2.1)","ISO 19642-7:2019-01 (p. 6.2.1)","ISO 19642-8:2019-01 (p. 6.2.1)","ISO 19642-9:2019-01 (p. 6.2.1)","ISO 19642-10:2019-01 (p. 6.2.1)","IEC 60811-203:2012-03 DIN/TS 70112-1:2024-03 (p. 7.4.2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Średnica zewnętrzna kabla/ powłoki\nZakres:\nZakres (0,01 - 25) mm\nCable outside diameter\nRange (0,01 - 25) mm ISO 6722-1:2011 + Cor.1:2012 (p. 5.1) | ISO 6722-2:2013 (p.5.1) | ISO 19642-2:2023-08 (p. 5.2.1, 6.2.1) | ISO 19642-3:2019-01 (p. 5.2.1) | ISO 19642-4:2019-01 (p. 5.2.1) | ISO 19642-5:2019-01 (p. 5.2.1) | ISO 19642-6:2019-01 (p. 5.2.1) | ISO 19642-7:2019-01 (p. 6.2.1) | ISO 19642-8:2019-01 (p. 6.2.1) | ISO 19642-9:2019-01 (p. 6.2.1) | ISO 19642-10:2019-01 (p. 6.2.1) | IEC 60811-203:2012-03 DIN/TS 70112-1:2024-03 (p. 7.4.2) Kable, Cables Srednica zewnetrzna kabla/ powloki\nZakres:\nZakres (0,01 - 25) mm\nCable outside diameter\nRange (0,01 - 25) mm ISO 6722-1:2011 + Cor.1:2012 (p. 5.1) | ISO 6722-2:2013 (p.5.1) | ISO 19642-2:2023-08 (p. 5.2.1, 6.2.1) | ISO 19642-3:2019-01 (p. 5.2.1) | ISO 19642-4:2019-01 (p. 5.2.1) | ISO 19642-5:2019-01 (p. 5.2.1) | ISO 19642-6:2019-01 (p. 5.2.1) | ISO 19642-7:2019-01 (p. 6.2.1) | ISO 19642-8:2019-01 (p. 6.2.1) | ISO 19642-9:2019-01 (p. 6.2.1) | ISO 19642-10:2019-01 (p. 6.2.1) | IEC 60811-203:2012-03 DIN/TS 70112-1:2024-03 (p. 7.4.2)","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables External diameter of the cable/ sheath Range Cable outside diameter Range ISO 6722-1:2011 + Cor.1:2012 (p. 5.1) | ISO 6722-2:2013 (p.5.1) | ISO 19642-2:2023-08 (p. 5.2.1, 6.2.1) | ISO 19642-3:2019-01 (p. 5.2.1) | ISO 19642-4:2019-01 (p. 5.2.1) | ISO 19642-5:2019-01 (p. 5.2.1) | ISO 19642-6:2019-01 (p. 5.2.1) | ISO 19642-7:2019-01 (p. 6.2.1) | ISO 19642-8:2019-01 (p. 6.2.1) | ISO 19642-9:2019-01 (p. 6.2.1) | ISO 19642-10:2019-01 (p. 6.2.1) | IEC 60811-203:2012-03 DIN/TS 70112-1:2024-03 (p. 7.4.2)","parameters_zh":[{"name":"范围","range":"(0,01 - 25) mm"},{"name":"Cable outside diameter"},{"name":"范围","range":"(0,01 - 25) mm"}],"search_zh":"电缆 范围 范围 ISO 6722-1:2011 + Cor.1:2012 (p. 5.1) | ISO 6722-2:2013 (p.5.1) | ISO 19642-2:2023-08 (p. 5.2.1, 6.2.1) | ISO 19642-3:2019-01 (p. 5.2.1) | ISO 19642-4:2019-01 (p. 5.2.1) | ISO 19642-5:2019-01 (p. 5.2.1) | ISO 19642-6:2019-01 (p. 5.2.1) | ISO 19642-7:2019-01 (p. 6.2.1) | ISO 19642-8:2019-01 (p. 6.2.1) | ISO 19642-9:2019-01 (p. 6.2.1) | ISO 19642-10:2019-01 (p. 6.2.1) | IEC 60811-203:2012-03 DIN/TS 70112-1:2024-03 (p. 7.4.2)","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a0e6","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Grubość izolacji / powłoki","methodology_en":"Thickness of insulation / coating","parameters":[{"name":"Zakres","range":"(0,01 - 25) mm"},{"name":"Insulation/sheath thickness"},{"name":"Range","range":"(0,01 - 25) mm"}],"parameters_en":[{"name":"Range","range":"(0,01 - 25) mm"},{"name":"Insulation/sheath thickness"},{"name":"Range","range":"(0,01 - 25) mm"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Grubość izolacji / powłoki\nZakres:\nZakres (0,01 - 25) mm\nInsulation/sheath thickness\nRange (0,01 - 25) mm","reference":"ISO 6722-1:2011 + Cor.1:2012 (p.5.2) | ISO 6722-2:2013 (p. 5.2) | ISO 19642-2:2023-08 (p. 5.2.2, 6.2.3) | ISO 19642-3:2019-01 (p. 5.2.2) | ISO 19642-4:2019-01 (p. 5.2.2) | ISO 19642-5:2019-01 (p. 5.2.2) | ISO 19642-6:2019-01 (p. 5.2.2) | ISO 19642-7:2019-01 (p. 6.2.3) | ISO 19642-8:2019-01 (p. 6.2.3) | ISO 19642-9:2019-01 (p. 6.2.3) | ISO 19642-10:2019-01 (p. 6.2.3) | IEC 60811-201:2012+AMD1:2017+AMD2:2023 | IEC 60811-202:2012+AMD1:2017+AMD2:2023 | IEC 60811-203:2012-03 DIN/TS 70112-1:2024-03 (p. 7.4.2)","norm_bases":["ISO 6722-1:2011 + Cor.1:2012 (p.5.2)","ISO 6722-2:2013 (p. 5.2)","ISO 19642-2:2023-08 (p. 5.2.2, 6.2.3)","ISO 19642-3:2019-01 (p. 5.2.2)","ISO 19642-4:2019-01 (p. 5.2.2)","ISO 19642-5:2019-01 (p. 5.2.2)","ISO 19642-6:2019-01 (p. 5.2.2)","ISO 19642-7:2019-01 (p. 6.2.3)","ISO 19642-8:2019-01 (p. 6.2.3)","ISO 19642-9:2019-01 (p. 6.2.3)","ISO 19642-10:2019-01 (p. 6.2.3)","IEC 60811-201:2012+AMD1:2017+AMD2:2023","IEC 60811-202:2012+AMD1:2017+AMD2:2023","IEC 60811-203:2012-03 DIN/TS 70112-1:2024-03 (p. 7.4.2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Grubość izolacji / powłoki\nZakres:\nZakres (0,01 - 25) mm\nInsulation/sheath thickness\nRange (0,01 - 25) mm ISO 6722-1:2011 + Cor.1:2012 (p.5.2) | ISO 6722-2:2013 (p. 5.2) | ISO 19642-2:2023-08 (p. 5.2.2, 6.2.3) | ISO 19642-3:2019-01 (p. 5.2.2) | ISO 19642-4:2019-01 (p. 5.2.2) | ISO 19642-5:2019-01 (p. 5.2.2) | ISO 19642-6:2019-01 (p. 5.2.2) | ISO 19642-7:2019-01 (p. 6.2.3) | ISO 19642-8:2019-01 (p. 6.2.3) | ISO 19642-9:2019-01 (p. 6.2.3) | ISO 19642-10:2019-01 (p. 6.2.3) | IEC 60811-201:2012+AMD1:2017+AMD2:2023 | IEC 60811-202:2012+AMD1:2017+AMD2:2023 | IEC 60811-203:2012-03 DIN/TS 70112-1:2024-03 (p. 7.4.2) Kable, Cables Grubosc izolacji / powloki\nZakres:\nZakres (0,01 - 25) mm\nInsulation/sheath thickness\nRange (0,01 - 25) mm ISO 6722-1:2011 + Cor.1:2012 (p.5.2) | ISO 6722-2:2013 (p. 5.2) | ISO 19642-2:2023-08 (p. 5.2.2, 6.2.3) | ISO 19642-3:2019-01 (p. 5.2.2) | ISO 19642-4:2019-01 (p. 5.2.2) | ISO 19642-5:2019-01 (p. 5.2.2) | ISO 19642-6:2019-01 (p. 5.2.2) | ISO 19642-7:2019-01 (p. 6.2.3) | ISO 19642-8:2019-01 (p. 6.2.3) | ISO 19642-9:2019-01 (p. 6.2.3) | ISO 19642-10:2019-01 (p. 6.2.3) | IEC 60811-201:2012+AMD1:2017+AMD2:2023 | IEC 60811-202:2012+AMD1:2017+AMD2:2023 | IEC 60811-203:2012-03 DIN/TS 70112-1:2024-03 (p. 7.4.2)","categories":["construction"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Thickness of insulation / coating Range Insulation/sheath thickness Range ISO 6722-1:2011 + Cor.1:2012 (p.5.2) | ISO 6722-2:2013 (p. 5.2) | ISO 19642-2:2023-08 (p. 5.2.2, 6.2.3) | ISO 19642-3:2019-01 (p. 5.2.2) | ISO 19642-4:2019-01 (p. 5.2.2) | ISO 19642-5:2019-01 (p. 5.2.2) | ISO 19642-6:2019-01 (p. 5.2.2) | ISO 19642-7:2019-01 (p. 6.2.3) | ISO 19642-8:2019-01 (p. 6.2.3) | ISO 19642-9:2019-01 (p. 6.2.3) | ISO 19642-10:2019-01 (p. 6.2.3) | IEC 60811-201:2012+AMD1:2017+AMD2:2023 | IEC 60811-202:2012+AMD1:2017+AMD2:2023 | IEC 60811-203:2012-03 DIN/TS 70112-1:2024-03 (p. 7.4.2)","parameters_zh":[{"name":"范围","range":"(0,01 - 25) mm"},{"name":"Insulation/sheath thickness"},{"name":"范围","range":"(0,01 - 25) mm"}],"search_zh":"电缆 范围 范围 ISO 6722-1:2011 + Cor.1:2012 (p.5.2) | ISO 6722-2:2013 (p. 5.2) | ISO 19642-2:2023-08 (p. 5.2.2, 6.2.3) | ISO 19642-3:2019-01 (p. 5.2.2) | ISO 19642-4:2019-01 (p. 5.2.2) | ISO 19642-5:2019-01 (p. 5.2.2) | ISO 19642-6:2019-01 (p. 5.2.2) | ISO 19642-7:2019-01 (p. 6.2.3) | ISO 19642-8:2019-01 (p. 6.2.3) | ISO 19642-9:2019-01 (p. 6.2.3) | ISO 19642-10:2019-01 (p. 6.2.3) | IEC 60811-201:2012+AMD1:2017+AMD2:2023 | IEC 60811-202:2012+AMD1:2017+AMD2:2023 | IEC 60811-203:2012-03 DIN/TS 70112-1:2024-03 (p. 7.4.2)","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a0e7","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Średnica przewodnika","methodology_en":"Conductor diameter","parameters":[{"name":"Zakres","range":"(0,01 - 25) mm"},{"name":"Conductor diameter"},{"name":"Range","range":"(0,01 - 25) mm"}],"parameters_en":[{"name":"Range","range":"(0,01 - 25) mm"},{"name":"Conductor diameter"},{"name":"Range","range":"(0,01 - 25) mm"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Średnica przewodnika\nZakres:\nZakres (0,01 - 25) mm\nConductor diameter\nRange (0,01 - 25) mm","reference":"ISO 6722-1:2011 + Cor.1:2012 (p. 5.3) | ISO 6722-2:2013 (p. 5.3.1) | ISO 19642-2:2023-08 (p. 5.2.3) | ISO 19642-3:2019-01 (p. 5.2.3) | ISO 19642-4:2019-01 (p. 5.2.3) | ISO 19642-5:2019-01 (p. 5.2.3) | ISO 19642-6:2019-01 (p. 5.2.3) | IEC 60811-203:2012-03 DIN/TS 70112-1:2024-03 (p. 7.4.3)","norm_bases":["ISO 6722-1:2011 + Cor.1:2012 (p. 5.3)","ISO 6722-2:2013 (p. 5.3.1)","ISO 19642-2:2023-08 (p. 5.2.3)","ISO 19642-3:2019-01 (p. 5.2.3)","ISO 19642-4:2019-01 (p. 5.2.3)","ISO 19642-5:2019-01 (p. 5.2.3)","ISO 19642-6:2019-01 (p. 5.2.3)","IEC 60811-203:2012-03 DIN/TS 70112-1:2024-03 (p. 7.4.3)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Średnica przewodnika\nZakres:\nZakres (0,01 - 25) mm\nConductor diameter\nRange (0,01 - 25) mm ISO 6722-1:2011 + Cor.1:2012 (p. 5.3) | ISO 6722-2:2013 (p. 5.3.1) | ISO 19642-2:2023-08 (p. 5.2.3) | ISO 19642-3:2019-01 (p. 5.2.3) | ISO 19642-4:2019-01 (p. 5.2.3) | ISO 19642-5:2019-01 (p. 5.2.3) | ISO 19642-6:2019-01 (p. 5.2.3) | IEC 60811-203:2012-03 DIN/TS 70112-1:2024-03 (p. 7.4.3) Kable, Cables Srednica przewodnika\nZakres:\nZakres (0,01 - 25) mm\nConductor diameter\nRange (0,01 - 25) mm ISO 6722-1:2011 + Cor.1:2012 (p. 5.3) | ISO 6722-2:2013 (p. 5.3.1) | ISO 19642-2:2023-08 (p. 5.2.3) | ISO 19642-3:2019-01 (p. 5.2.3) | ISO 19642-4:2019-01 (p. 5.2.3) | ISO 19642-5:2019-01 (p. 5.2.3) | ISO 19642-6:2019-01 (p. 5.2.3) | IEC 60811-203:2012-03 DIN/TS 70112-1:2024-03 (p. 7.4.3)","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Conductor diameter Range Conductor diameter Range ISO 6722-1:2011 + Cor.1:2012 (p. 5.3) | ISO 6722-2:2013 (p. 5.3.1) | ISO 19642-2:2023-08 (p. 5.2.3) | ISO 19642-3:2019-01 (p. 5.2.3) | ISO 19642-4:2019-01 (p. 5.2.3) | ISO 19642-5:2019-01 (p. 5.2.3) | ISO 19642-6:2019-01 (p. 5.2.3) | IEC 60811-203:2012-03 DIN/TS 70112-1:2024-03 (p. 7.4.3)","parameters_zh":[{"name":"范围","range":"(0,01 - 25) mm"},{"name":"Conductor diameter"},{"name":"范围","range":"(0,01 - 25) mm"}],"search_zh":"电缆 范围 范围 ISO 6722-1:2011 + Cor.1:2012 (p. 5.3) | ISO 6722-2:2013 (p. 5.3.1) | ISO 19642-2:2023-08 (p. 5.2.3) | ISO 19642-3:2019-01 (p. 5.2.3) | ISO 19642-4:2019-01 (p. 5.2.3) | ISO 19642-5:2019-01 (p. 5.2.3) | ISO 19642-6:2019-01 (p. 5.2.3) | IEC 60811-203:2012-03 DIN/TS 70112-1:2024-03 (p. 7.4.3)","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a0e8","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Powierzchnia przekroju przewodnika, Cross-sectional area (CSA)","methodology_en":"Conductor cross-sectional area (CSA)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Powierzchnia przekroju przewodnika, Cross-sectional area (CSA)","reference":"ISO 19642-2:2023-08 (p. 5.2.4) | ISO 19642-3:2019-01 (p. 5.2.4) | ISO 19642-4:2019-01 (p. 5.2.4) | ISO 19642-5:2019-01 (p. 5.2.4) | ISO 19642-6:2019-01 (p. 5.2.4) | ISO 6722-2:2013 (p. 5.3.2.2.2) Scope of accreditation No. AB 1814","norm_bases":["ISO 19642-2:2023-08 (p. 5.2.4)","ISO 19642-3:2019-01 (p. 5.2.4)","ISO 19642-4:2019-01 (p. 5.2.4)","ISO 19642-5:2019-01 (p. 5.2.4)","ISO 19642-6:2019-01 (p. 5.2.4)","ISO 6722-2:2013 (p. 5.3.2.2.2) Scope of accreditation No. AB 1814"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Powierzchnia przekroju przewodnika, Cross-sectional area (CSA) ISO 19642-2:2023-08 (p. 5.2.4) | ISO 19642-3:2019-01 (p. 5.2.4) | ISO 19642-4:2019-01 (p. 5.2.4) | ISO 19642-5:2019-01 (p. 5.2.4) | ISO 19642-6:2019-01 (p. 5.2.4) | ISO 6722-2:2013 (p. 5.3.2.2.2) Scope of accreditation No. AB 1814 Kable, Cables Powierzchnia przekroju przewodnika, Cross-sectional area (CSA) ISO 19642-2:2023-08 (p. 5.2.4) | ISO 19642-3:2019-01 (p. 5.2.4) | ISO 19642-4:2019-01 (p. 5.2.4) | ISO 19642-5:2019-01 (p. 5.2.4) | ISO 19642-6:2019-01 (p. 5.2.4) | ISO 6722-2:2013 (p. 5.3.2.2.2) Scope of accreditation No. AB 1814","categories":["other"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Conductor cross-sectional area (CSA) ISO 19642-2:2023-08 (p. 5.2.4) | ISO 19642-3:2019-01 (p. 5.2.4) | ISO 19642-4:2019-01 (p. 5.2.4) | ISO 19642-5:2019-01 (p. 5.2.4) | ISO 19642-6:2019-01 (p. 5.2.4) | ISO 6722-2:2013 (p. 5.3.2.2.2) Scope of accreditation No. AB 1814","search_zh":"电缆 ISO 19642-2:2023-08 (p. 5.2.4) | ISO 19642-3:2019-01 (p. 5.2.4) | ISO 19642-4:2019-01 (p. 5.2.4) | ISO 19642-5:2019-01 (p. 5.2.4) | ISO 19642-6:2019-01 (p. 5.2.4) | ISO 6722-2:2013 (p. 5.3.2.2.2) Scope of accreditation No. AB 1814","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a0e9","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Pomiar rezystancji:","methodology_en":"Resistance measurement:","parameters":[{"name":"przewodnika"},{"name":"ekranu"},{"name":"kabla skręconego"},{"name":"Zakres","range":"(0,1 – 200 000) mΩ/m"}],"parameters_en":[{"name":"conductor"},{"name":"screen"},{"name":"twisted cable"},{"name":"Range","range":"(0,1 – 200 000) mΩ/m"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pomiar rezystancji:\nZakres:\nprzewodnika\nekranu\nkabla skręconego\nZakres (0,1 – 200 000) mΩ/m","reference":"ISO 6722-1:2011 + Cor.1:2012 (p. 5.4) | ISO 19642-2:2023-08 (p. 5.3.1; p. 6.3.3.2) | ISO 19642-3:2019-01 (p. 5.3.1) | ISO 19642-4:2019-01 (p. 5.3.1) | ISO 19642-5:2019-01 (p. 5.3.1) | ISO 19642-6:2019-01 (p. 5.3.1) | ISO 19642-7:2019-01 (p. 6.3.3.2) | ISO 19642-8:2019-01 (p. 6.3.3.2) | ISO 19642-9:2019-01 (p. 6.3.3.2) | ISO 19642-10:2019-01 (p. 6.3.3.2) | IEC 60228:2004 VW 60306-1:2021-10 (p. 9.2.4) VW 60306-2:2021-11 (p. 9.2.4) VW 60306-4:2021-12 (p. 9.2.4) DIN/TS 70112-1:2024-03 (p. 7.4.4)","norm_bases":["ISO 6722-1:2011 + Cor.1:2012 (p. 5.4)","ISO 19642-2:2023-08 (p. 5.3.1; p. 6.3.3.2)","ISO 19642-3:2019-01 (p. 5.3.1)","ISO 19642-4:2019-01 (p. 5.3.1)","ISO 19642-5:2019-01 (p. 5.3.1)","ISO 19642-6:2019-01 (p. 5.3.1)","ISO 19642-7:2019-01 (p. 6.3.3.2)","ISO 19642-8:2019-01 (p. 6.3.3.2)","ISO 19642-9:2019-01 (p. 6.3.3.2)","ISO 19642-10:2019-01 (p. 6.3.3.2)","IEC 60228:2004 VW 60306-1:2021-10 (p. 9.2.4) VW 60306-2:2021-11 (p. 9.2.4) VW 60306-4:2021-12 (p. 9.2.4) DIN/TS 70112-1:2024-03 (p. 7.4.4)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Pomiar rezystancji:\nZakres:\nprzewodnika\nekranu\nkabla skręconego\nZakres (0,1 – 200 000) mΩ/m ISO 6722-1:2011 + Cor.1:2012 (p. 5.4) | ISO 19642-2:2023-08 (p. 5.3.1; p. 6.3.3.2) | ISO 19642-3:2019-01 (p. 5.3.1) | ISO 19642-4:2019-01 (p. 5.3.1) | ISO 19642-5:2019-01 (p. 5.3.1) | ISO 19642-6:2019-01 (p. 5.3.1) | ISO 19642-7:2019-01 (p. 6.3.3.2) | ISO 19642-8:2019-01 (p. 6.3.3.2) | ISO 19642-9:2019-01 (p. 6.3.3.2) | ISO 19642-10:2019-01 (p. 6.3.3.2) | IEC 60228:2004 VW 60306-1:2021-10 (p. 9.2.4) VW 60306-2:2021-11 (p. 9.2.4) VW 60306-4:2021-12 (p. 9.2.4) DIN/TS 70112-1:2024-03 (p. 7.4.4) Kable, Cables Pomiar rezystancji:\nZakres:\nprzewodnika\nekranu\nkabla skreconego\nZakres (0,1 – 200 000) mΩ/m ISO 6722-1:2011 + Cor.1:2012 (p. 5.4) | ISO 19642-2:2023-08 (p. 5.3.1; p. 6.3.3.2) | ISO 19642-3:2019-01 (p. 5.3.1) | ISO 19642-4:2019-01 (p. 5.3.1) | ISO 19642-5:2019-01 (p. 5.3.1) | ISO 19642-6:2019-01 (p. 5.3.1) | ISO 19642-7:2019-01 (p. 6.3.3.2) | ISO 19642-8:2019-01 (p. 6.3.3.2) | ISO 19642-9:2019-01 (p. 6.3.3.2) | ISO 19642-10:2019-01 (p. 6.3.3.2) | IEC 60228:2004 VW 60306-1:2021-10 (p. 9.2.4) VW 60306-2:2021-11 (p. 9.2.4) VW 60306-4:2021-12 (p. 9.2.4) DIN/TS 70112-1:2024-03 (p. 7.4.4)","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Resistance measurement: conductor screen twisted cable Range ISO 6722-1:2011 + Cor.1:2012 (p. 5.4) | ISO 19642-2:2023-08 (p. 5.3.1; p. 6.3.3.2) | ISO 19642-3:2019-01 (p. 5.3.1) | ISO 19642-4:2019-01 (p. 5.3.1) | ISO 19642-5:2019-01 (p. 5.3.1) | ISO 19642-6:2019-01 (p. 5.3.1) | ISO 19642-7:2019-01 (p. 6.3.3.2) | ISO 19642-8:2019-01 (p. 6.3.3.2) | ISO 19642-9:2019-01 (p. 6.3.3.2) | ISO 19642-10:2019-01 (p. 6.3.3.2) | IEC 60228:2004 VW 60306-1:2021-10 (p. 9.2.4) VW 60306-2:2021-11 (p. 9.2.4) VW 60306-4:2021-12 (p. 9.2.4) DIN/TS 70112-1:2024-03 (p. 7.4.4)","parameters_zh":[{"name":"przewodnika"},{"name":"ekranu"},{"name":"kabla skręconego"},{"name":"范围","range":"(0,1 – 200 000) mΩ/m"}],"search_zh":"电缆 范围 ISO 6722-1:2011 + Cor.1:2012 (p. 5.4) | ISO 19642-2:2023-08 (p. 5.3.1; p. 6.3.3.2) | ISO 19642-3:2019-01 (p. 5.3.1) | ISO 19642-4:2019-01 (p. 5.3.1) | ISO 19642-5:2019-01 (p. 5.3.1) | ISO 19642-6:2019-01 (p. 5.3.1) | ISO 19642-7:2019-01 (p. 6.3.3.2) | ISO 19642-8:2019-01 (p. 6.3.3.2) | ISO 19642-9:2019-01 (p. 6.3.3.2) | ISO 19642-10:2019-01 (p. 6.3.3.2) | IEC 60228:2004 VW 60306-1:2021-10 (p. 9.2.4) VW 60306-2:2021-11 (p. 9.2.4) VW 60306-4:2021-12 (p. 9.2.4) DIN/TS 70112-1:2024-03 (p. 7.4.4)","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a0ea","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Wytrzymałość napięciowa (30 minut)","methodology_en":"Voltage withstand (30 minutes)","parameters":[{"name":"Zakres","range":"(1 – 12) kV A.C. (50, 60Hz)"},{"name":"Zakres","range":"(1 – 16) kV D.C."},{"name":"Withstand voltage","range":"(30 min)"},{"name":"Range: (1 – 12) kV A.C.","range":"(50, 60Hz)"},{"name":"(1 – 16) kV D.C."}],"parameters_en":[{"name":"Range","range":"(1 – 12) kV A.C. (50, 60Hz)"},{"name":"Range","range":"(1 – 16) kV D.C."},{"name":"Withstand voltage","range":"(30 min)"},{"name":"Range: (1 – 12) kV A.C.","range":"(50, 60Hz)"},{"name":"(1 – 16) kV D.C."}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość napięciowa (30 minut)\nZakres:\nZakres (1 – 12) kV A.C. (50, 60Hz)\nZakres (1 – 16) kV D.C.\nWithstand voltage (30 min)\nRange: (1 – 12) kV A.C. (50, 60Hz)\n(1 – 16) kV D.C.","reference":"ISO 19642-2:2023-08 (p. 5.3.3) | ISO 19642-3:2019-01 (p. 5.3.3) | ISO 19642-4:2019-01 (p. 5.3.3) | ISO 19642-5:2019-01 (p. 5.3.3) | ISO 19642-6:2019-01 (p. 5.3.3) | ISO 6722-1:2011 + Cor.1:2012 (p. 5.5) | ISO 6722-2:2013 (p. 5.5) VW 60306-1:2021-10 (p. 9.6.2) VW 60306-2:2021-11 (p. 9.6.2) VW 60306-4:2021-12 (p. 9.6.2) DIN/TS 70112-1:2024-03 (p. 7.7.2)","norm_bases":["ISO 19642-2:2023-08 (p. 5.3.3)","ISO 19642-3:2019-01 (p. 5.3.3)","ISO 19642-4:2019-01 (p. 5.3.3)","ISO 19642-5:2019-01 (p. 5.3.3)","ISO 19642-6:2019-01 (p. 5.3.3)","ISO 6722-1:2011 + Cor.1:2012 (p. 5.5)","ISO 6722-2:2013 (p. 5.5) VW 60306-1:2021-10 (p. 9.6.2) VW 60306-2:2021-11 (p. 9.6.2) VW 60306-4:2021-12 (p. 9.6.2) DIN/TS 70112-1:2024-03 (p. 7.7.2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Wytrzymałość napięciowa (30 minut)\nZakres:\nZakres (1 – 12) kV A.C. (50, 60Hz)\nZakres (1 – 16) kV D.C.\nWithstand voltage (30 min)\nRange: (1 – 12) kV A.C. (50, 60Hz)\n(1 – 16) kV D.C. ISO 19642-2:2023-08 (p. 5.3.3) | ISO 19642-3:2019-01 (p. 5.3.3) | ISO 19642-4:2019-01 (p. 5.3.3) | ISO 19642-5:2019-01 (p. 5.3.3) | ISO 19642-6:2019-01 (p. 5.3.3) | ISO 6722-1:2011 + Cor.1:2012 (p. 5.5) | ISO 6722-2:2013 (p. 5.5) VW 60306-1:2021-10 (p. 9.6.2) VW 60306-2:2021-11 (p. 9.6.2) VW 60306-4:2021-12 (p. 9.6.2) DIN/TS 70112-1:2024-03 (p. 7.7.2) Kable, Cables Wytrzymalosc napieciowa (30 minut)\nZakres:\nZakres (1 – 12) kV A.C. (50, 60Hz)\nZakres (1 – 16) kV D.C.\nWithstand voltage (30 min)\nRange: (1 – 12) kV A.C. (50, 60Hz)\n(1 – 16) kV D.C. ISO 19642-2:2023-08 (p. 5.3.3) | ISO 19642-3:2019-01 (p. 5.3.3) | ISO 19642-4:2019-01 (p. 5.3.3) | ISO 19642-5:2019-01 (p. 5.3.3) | ISO 19642-6:2019-01 (p. 5.3.3) | ISO 6722-1:2011 + Cor.1:2012 (p. 5.5) | ISO 6722-2:2013 (p. 5.5) VW 60306-1:2021-10 (p. 9.6.2) VW 60306-2:2021-11 (p. 9.6.2) VW 60306-4:2021-12 (p. 9.6.2) DIN/TS 70112-1:2024-03 (p. 7.7.2)","categories":["other"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Voltage withstand (30 minutes) Range Range Withstand voltage Range: (1 – 12) kV A.C. (1 – 16) kV D.C. ISO 19642-2:2023-08 (p. 5.3.3) | ISO 19642-3:2019-01 (p. 5.3.3) | ISO 19642-4:2019-01 (p. 5.3.3) | ISO 19642-5:2019-01 (p. 5.3.3) | ISO 19642-6:2019-01 (p. 5.3.3) | ISO 6722-1:2011 + Cor.1:2012 (p. 5.5) | ISO 6722-2:2013 (p. 5.5) VW 60306-1:2021-10 (p. 9.6.2) VW 60306-2:2021-11 (p. 9.6.2) VW 60306-4:2021-12 (p. 9.6.2) DIN/TS 70112-1:2024-03 (p. 7.7.2)","parameters_zh":[{"name":"范围","range":"(1 – 12) kV A.C. (50, 60Hz)"},{"name":"范围","range":"(1 – 16) kV D.C."},{"name":"Withstand voltage","range":"(30 min)"},{"name":"Range: (1 – 12) kV A.C.","range":"(50, 60Hz)"},{"name":"(1 – 16) kV D.C."}],"search_zh":"电缆 范围 范围 ISO 19642-2:2023-08 (p. 5.3.3) | ISO 19642-3:2019-01 (p. 5.3.3) | ISO 19642-4:2019-01 (p. 5.3.3) | ISO 19642-5:2019-01 (p. 5.3.3) | ISO 19642-6:2019-01 (p. 5.3.3) | ISO 6722-1:2011 + Cor.1:2012 (p. 5.5) | ISO 6722-2:2013 (p. 5.5) VW 60306-1:2021-10 (p. 9.6.2) VW 60306-2:2021-11 (p. 9.6.2) VW 60306-4:2021-12 (p. 9.6.2) DIN/TS 70112-1:2024-03 (p. 7.7.2)","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a0eb","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Wytrzymałość napięciowa po testach środowiskowych (1 minuta)","methodology_en":"Voltage withstand after environmental tests (1 minute)","parameters":[{"name":"Zakres","range":"(1 – 12) kV A.C. (50, 60Hz)"},{"name":"Zakres","range":"(1 – 16) kV D.C."},{"name":"Withstand voltage after environmental"}],"parameters_en":[{"name":"Range","range":"(1 – 12) kV A.C. (50, 60Hz)"},{"name":"Range","range":"(1 – 16) kV D.C."},{"name":"Withstand voltage after environmental"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość napięciowa po testach środowiskowych (1 minuta)\nZakres:\nZakres (1 – 12) kV A.C. (50, 60Hz)\nZakres (1 – 16) kV D.C.\nWithstand voltage after environmental","reference":"ISO 19642-2:2023-08 (p. 5.3.4) | ISO 19642-2:2023-08 (p. 6.3.2) | ISO 19642-3:2019-01 (p. 5.3.4) | ISO 19642-4:2019-01 (p. 5.3.4) | ISO 19642-5:2019-01 (p. 5.3.4) | ISO 19642-6:2019-01 (p. 5.3.4) | ISO 19642-7:2019-01 (p. 6.3.2) | ISO 19642-8:2019-01 (p. 6.3.2) | ISO 19642-9:2019-01 (p. 6.3.2) | ISO 19642-10:2019-01 (p. 6.3.2) VW 60306-1:2021-10 (p. 9.6.3) VW 60306-2:2021-11 (p. 9.6.3) VW 60306-4:2021-12 (p. 9.6.3) DIN/TS 70112-1:2024-03 (p. 7.9.2)","norm_bases":["ISO 19642-2:2023-08 (p. 5.3.4)","ISO 19642-2:2023-08 (p. 6.3.2)","ISO 19642-3:2019-01 (p. 5.3.4)","ISO 19642-4:2019-01 (p. 5.3.4)","ISO 19642-5:2019-01 (p. 5.3.4)","ISO 19642-6:2019-01 (p. 5.3.4)","ISO 19642-7:2019-01 (p. 6.3.2)","ISO 19642-8:2019-01 (p. 6.3.2)","ISO 19642-9:2019-01 (p. 6.3.2)","ISO 19642-10:2019-01 (p. 6.3.2) VW 60306-1:2021-10 (p. 9.6.3) VW 60306-2:2021-11 (p. 9.6.3) VW 60306-4:2021-12 (p. 9.6.3) DIN/TS 70112-1:2024-03 (p. 7.9.2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Wytrzymałość napięciowa po testach środowiskowych (1 minuta)\nZakres:\nZakres (1 – 12) kV A.C. (50, 60Hz)\nZakres (1 – 16) kV D.C.\nWithstand voltage after environmental ISO 19642-2:2023-08 (p. 5.3.4) | ISO 19642-2:2023-08 (p. 6.3.2) | ISO 19642-3:2019-01 (p. 5.3.4) | ISO 19642-4:2019-01 (p. 5.3.4) | ISO 19642-5:2019-01 (p. 5.3.4) | ISO 19642-6:2019-01 (p. 5.3.4) | ISO 19642-7:2019-01 (p. 6.3.2) | ISO 19642-8:2019-01 (p. 6.3.2) | ISO 19642-9:2019-01 (p. 6.3.2) | ISO 19642-10:2019-01 (p. 6.3.2) VW 60306-1:2021-10 (p. 9.6.3) VW 60306-2:2021-11 (p. 9.6.3) VW 60306-4:2021-12 (p. 9.6.3) DIN/TS 70112-1:2024-03 (p. 7.9.2) Kable, Cables Wytrzymalosc napieciowa po testach srodowiskowych (1 minuta)\nZakres:\nZakres (1 – 12) kV A.C. (50, 60Hz)\nZakres (1 – 16) kV D.C.\nWithstand voltage after environmental ISO 19642-2:2023-08 (p. 5.3.4) | ISO 19642-2:2023-08 (p. 6.3.2) | ISO 19642-3:2019-01 (p. 5.3.4) | ISO 19642-4:2019-01 (p. 5.3.4) | ISO 19642-5:2019-01 (p. 5.3.4) | ISO 19642-6:2019-01 (p. 5.3.4) | ISO 19642-7:2019-01 (p. 6.3.2) | ISO 19642-8:2019-01 (p. 6.3.2) | ISO 19642-9:2019-01 (p. 6.3.2) | ISO 19642-10:2019-01 (p. 6.3.2) VW 60306-1:2021-10 (p. 9.6.3) VW 60306-2:2021-11 (p. 9.6.3) VW 60306-4:2021-12 (p. 9.6.3) DIN/TS 70112-1:2024-03 (p. 7.9.2)","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Voltage withstand after environmental tests (1 minute) Range Range Withstand voltage after environmental ISO 19642-2:2023-08 (p. 5.3.4) | ISO 19642-2:2023-08 (p. 6.3.2) | ISO 19642-3:2019-01 (p. 5.3.4) | ISO 19642-4:2019-01 (p. 5.3.4) | ISO 19642-5:2019-01 (p. 5.3.4) | ISO 19642-6:2019-01 (p. 5.3.4) | ISO 19642-7:2019-01 (p. 6.3.2) | ISO 19642-8:2019-01 (p. 6.3.2) | ISO 19642-9:2019-01 (p. 6.3.2) | ISO 19642-10:2019-01 (p. 6.3.2) VW 60306-1:2021-10 (p. 9.6.3) VW 60306-2:2021-11 (p. 9.6.3) VW 60306-4:2021-12 (p. 9.6.3) DIN/TS 70112-1:2024-03 (p. 7.9.2)","parameters_zh":[{"name":"范围","range":"(1 – 12) kV A.C. (50, 60Hz)"},{"name":"范围","range":"(1 – 16) kV D.C."},{"name":"Withstand voltage after environmental"}],"search_zh":"电缆 范围 范围 ISO 19642-2:2023-08 (p. 5.3.4) | ISO 19642-2:2023-08 (p. 6.3.2) | ISO 19642-3:2019-01 (p. 5.3.4) | ISO 19642-4:2019-01 (p. 5.3.4) | ISO 19642-5:2019-01 (p. 5.3.4) | ISO 19642-6:2019-01 (p. 5.3.4) | ISO 19642-7:2019-01 (p. 6.3.2) | ISO 19642-8:2019-01 (p. 6.3.2) | ISO 19642-9:2019-01 (p. 6.3.2) | ISO 19642-10:2019-01 (p. 6.3.2) VW 60306-1:2021-10 (p. 9.6.3) VW 60306-2:2021-11 (p. 9.6.3) VW 60306-4:2021-12 (p. 9.6.3) DIN/TS 70112-1:2024-03 (p. 7.9.2)","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a0ec","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Siła zrywająca gotowy kabel","methodology_en":"Breaking force of the finished cable","parameters":[{"name":"Maszyna wytrzymałościowa:"},{"name":"Zakres","range":"(0,2 – 2500) N"}],"parameters_en":[{"name":"Testing machine:"},{"name":"Range","range":"(0,2 – 2500) N"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła zrywająca gotowy kabel\nZakres:\nMaszyna wytrzymałościowa:\nZakres (0,2 – 2500) N","reference":"ISO 19642-2:2023-08 (p. 5.4.3) | ISO 19642-3:2019-01 (p. 5.4.3) | ISO 19642-4:2019-01 (p. 5.4.3) | ISO 19642-5:2019-01 (p. 5.4.3) | ISO 19642-6:2019-01 (p. 5.4.3) VW 60306-4:2021-12 (p. 9.3.5.2) Scope of accreditation No. AB 1814","norm_bases":["ISO 19642-2:2023-08 (p. 5.4.3)","ISO 19642-3:2019-01 (p. 5.4.3)","ISO 19642-4:2019-01 (p. 5.4.3)","ISO 19642-5:2019-01 (p. 5.4.3)","ISO 19642-6:2019-01 (p. 5.4.3) VW 60306-4:2021-12 (p. 9.3.5.2) Scope of accreditation No. AB 1814"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Siła zrywająca gotowy kabel\nZakres:\nMaszyna wytrzymałościowa:\nZakres (0,2 – 2500) N ISO 19642-2:2023-08 (p. 5.4.3) | ISO 19642-3:2019-01 (p. 5.4.3) | ISO 19642-4:2019-01 (p. 5.4.3) | ISO 19642-5:2019-01 (p. 5.4.3) | ISO 19642-6:2019-01 (p. 5.4.3) VW 60306-4:2021-12 (p. 9.3.5.2) Scope of accreditation No. AB 1814 Kable, Cables Sila zrywajaca gotowy kabel\nZakres:\nMaszyna wytrzymalosciowa:\nZakres (0,2 – 2500) N ISO 19642-2:2023-08 (p. 5.4.3) | ISO 19642-3:2019-01 (p. 5.4.3) | ISO 19642-4:2019-01 (p. 5.4.3) | ISO 19642-5:2019-01 (p. 5.4.3) | ISO 19642-6:2019-01 (p. 5.4.3) VW 60306-4:2021-12 (p. 9.3.5.2) Scope of accreditation No. AB 1814","categories":["other"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Breaking force of the finished cable Testing machine: Range ISO 19642-2:2023-08 (p. 5.4.3) | ISO 19642-3:2019-01 (p. 5.4.3) | ISO 19642-4:2019-01 (p. 5.4.3) | ISO 19642-5:2019-01 (p. 5.4.3) | ISO 19642-6:2019-01 (p. 5.4.3) VW 60306-4:2021-12 (p. 9.3.5.2) Scope of accreditation No. AB 1814","parameters_zh":[{"name":"材料试验机："},{"name":"范围","range":"(0,2 – 2500) N"}],"search_zh":"电缆 材料试验机： 范围 ISO 19642-2:2023-08 (p. 5.4.3) | ISO 19642-3:2019-01 (p. 5.4.3) | ISO 19642-4:2019-01 (p. 5.4.3) | ISO 19642-5:2019-01 (p. 5.4.3) | ISO 19642-6:2019-01 (p. 5.4.3) VW 60306-4:2021-12 (p. 9.3.5.2) Scope of accreditation No. AB 1814","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a0ed","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Odporność izolacji / powłoki kabla na przetarcie","methodology_en":"Resistance of cable insulation / sheath to abrasion","parameters":[{"name":"Zakres","range":"nominalne pole przekroju prze-"},{"name":"wodnika","range":"do 6 mm2"}],"parameters_en":[{"name":"Range","range":"nominalne pole przekroju prze-"},{"name":"wodnika","range":"do 6 mm2"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność izolacji / powłoki kabla na przetarcie\nZakres:\nZakres nominalne pole przekroju prze-\nwodnika do 6 mm2","reference":"ISO 19642-2:2023-08 (p. 5.4.2.5) | ISO 19642-3:2019-01 (p. 5.4.2.3) | ISO 19642-4:2019-01 (p. 5.4.2.3) | ISO 19642-5:2019-01 (p. 5.4.2.3) | ISO 19642-6:2019-01 (p. 5.4.2.3) | ISO 6722-1:2011; corr.1:2012 (p. 5.12.4.2) | ISO 6722-2:2013 (p. 5.12) VW 60306-1:2021-10 (p. 9.4.2) VW 60306-2:2021-11 (p. 9.4.2) VW 60306-4:2021-12 (p. 9.4.2) VW 75210-1:2024-08 (p. 9.4.2) DIN/TS 70112-1:2024-03 (p. 7.6.2)","norm_bases":["ISO 19642-2:2023-08 (p. 5.4.2.5)","ISO 19642-3:2019-01 (p. 5.4.2.3)","ISO 19642-4:2019-01 (p. 5.4.2.3)","ISO 19642-5:2019-01 (p. 5.4.2.3)","ISO 19642-6:2019-01 (p. 5.4.2.3)","ISO 6722-1:2011; corr.1:2012 (p. 5.12.4.2)","ISO 6722-2:2013 (p. 5.12) VW 60306-1:2021-10 (p. 9.4.2) VW 60306-2:2021-11 (p. 9.4.2) VW 60306-4:2021-12 (p. 9.4.2) VW 75210-1:2024-08 (p. 9.4.2) DIN/TS 70112-1:2024-03 (p. 7.6.2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Odporność izolacji / powłoki kabla na przetarcie\nZakres:\nZakres nominalne pole przekroju prze-\nwodnika do 6 mm2 ISO 19642-2:2023-08 (p. 5.4.2.5) | ISO 19642-3:2019-01 (p. 5.4.2.3) | ISO 19642-4:2019-01 (p. 5.4.2.3) | ISO 19642-5:2019-01 (p. 5.4.2.3) | ISO 19642-6:2019-01 (p. 5.4.2.3) | ISO 6722-1:2011; corr.1:2012 (p. 5.12.4.2) | ISO 6722-2:2013 (p. 5.12) VW 60306-1:2021-10 (p. 9.4.2) VW 60306-2:2021-11 (p. 9.4.2) VW 60306-4:2021-12 (p. 9.4.2) VW 75210-1:2024-08 (p. 9.4.2) DIN/TS 70112-1:2024-03 (p. 7.6.2) Kable, Cables Odpornosc izolacji / powloki kabla na przetarcie\nZakres:\nZakres nominalne pole przekroju prze-\nwodnika do 6 mm2 ISO 19642-2:2023-08 (p. 5.4.2.5) | ISO 19642-3:2019-01 (p. 5.4.2.3) | ISO 19642-4:2019-01 (p. 5.4.2.3) | ISO 19642-5:2019-01 (p. 5.4.2.3) | ISO 19642-6:2019-01 (p. 5.4.2.3) | ISO 6722-1:2011; corr.1:2012 (p. 5.12.4.2) | ISO 6722-2:2013 (p. 5.12) VW 60306-1:2021-10 (p. 9.4.2) VW 60306-2:2021-11 (p. 9.4.2) VW 60306-4:2021-12 (p. 9.4.2) VW 75210-1:2024-08 (p. 9.4.2) DIN/TS 70112-1:2024-03 (p. 7.6.2)","categories":["construction"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Resistance of cable insulation / sheath to abrasion Range wodnika ISO 19642-2:2023-08 (p. 5.4.2.5) | ISO 19642-3:2019-01 (p. 5.4.2.3) | ISO 19642-4:2019-01 (p. 5.4.2.3) | ISO 19642-5:2019-01 (p. 5.4.2.3) | ISO 19642-6:2019-01 (p. 5.4.2.3) | ISO 6722-1:2011; corr.1:2012 (p. 5.12.4.2) | ISO 6722-2:2013 (p. 5.12) VW 60306-1:2021-10 (p. 9.4.2) VW 60306-2:2021-11 (p. 9.4.2) VW 60306-4:2021-12 (p. 9.4.2) VW 75210-1:2024-08 (p. 9.4.2) DIN/TS 70112-1:2024-03 (p. 7.6.2)","parameters_zh":[{"name":"范围","range":"nominalne pole przekroju prze-"},{"name":"wodnika","range":"do 6 mm2"}],"search_zh":"电缆 范围 ISO 19642-2:2023-08 (p. 5.4.2.5) | ISO 19642-3:2019-01 (p. 5.4.2.3) | ISO 19642-4:2019-01 (p. 5.4.2.3) | ISO 19642-5:2019-01 (p. 5.4.2.3) | ISO 19642-6:2019-01 (p. 5.4.2.3) | ISO 6722-1:2011; corr.1:2012 (p. 5.12.4.2) | ISO 6722-2:2013 (p. 5.12) VW 60306-1:2021-10 (p. 9.4.2) VW 60306-2:2021-11 (p. 9.4.2) VW 60306-4:2021-12 (p. 9.4.2) VW 75210-1:2024-08 (p. 9.4.2) DIN/TS 70112-1:2024-03 (p. 7.6.2)","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a0ee","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Test nawijania kabla, Winding test","methodology_en":"Winding test","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Test nawijania kabla, Winding test","reference":"ISO 19642-2:2023-08 (p. 5.5.1) | ISO 19642-2:2023-08 (p. 6.5.1) | ISO 19642-3:2019-01 (p. 5.5.1) | ISO 19642-4:2019-01 (p. 5.5.1) | ISO 19642-5:2019-01 (p. 5.5.1) | ISO 19642-6:2019-01 (p. 5.5.1) | ISO 19642-7:2019-01 (p. 6.5.1) | ISO 19642-8:2019-01 (p. 6.5.1) | ISO 19642-9:2019-01 (p. 6.5.1) | ISO 19642-10:2019-01 (p. 6.5.1)","norm_bases":["ISO 19642-2:2023-08 (p. 5.5.1)","ISO 19642-2:2023-08 (p. 6.5.1)","ISO 19642-3:2019-01 (p. 5.5.1)","ISO 19642-4:2019-01 (p. 5.5.1)","ISO 19642-5:2019-01 (p. 5.5.1)","ISO 19642-6:2019-01 (p. 5.5.1)","ISO 19642-7:2019-01 (p. 6.5.1)","ISO 19642-8:2019-01 (p. 6.5.1)","ISO 19642-9:2019-01 (p. 6.5.1)","ISO 19642-10:2019-01 (p. 6.5.1)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Test nawijania kabla, Winding test ISO 19642-2:2023-08 (p. 5.5.1) | ISO 19642-2:2023-08 (p. 6.5.1) | ISO 19642-3:2019-01 (p. 5.5.1) | ISO 19642-4:2019-01 (p. 5.5.1) | ISO 19642-5:2019-01 (p. 5.5.1) | ISO 19642-6:2019-01 (p. 5.5.1) | ISO 19642-7:2019-01 (p. 6.5.1) | ISO 19642-8:2019-01 (p. 6.5.1) | ISO 19642-9:2019-01 (p. 6.5.1) | ISO 19642-10:2019-01 (p. 6.5.1) Kable, Cables Test nawijania kabla, Winding test ISO 19642-2:2023-08 (p. 5.5.1) | ISO 19642-2:2023-08 (p. 6.5.1) | ISO 19642-3:2019-01 (p. 5.5.1) | ISO 19642-4:2019-01 (p. 5.5.1) | ISO 19642-5:2019-01 (p. 5.5.1) | ISO 19642-6:2019-01 (p. 5.5.1) | ISO 19642-7:2019-01 (p. 6.5.1) | ISO 19642-8:2019-01 (p. 6.5.1) | ISO 19642-9:2019-01 (p. 6.5.1) | ISO 19642-10:2019-01 (p. 6.5.1)","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Winding test ISO 19642-2:2023-08 (p. 5.5.1) | ISO 19642-2:2023-08 (p. 6.5.1) | ISO 19642-3:2019-01 (p. 5.5.1) | ISO 19642-4:2019-01 (p. 5.5.1) | ISO 19642-5:2019-01 (p. 5.5.1) | ISO 19642-6:2019-01 (p. 5.5.1) | ISO 19642-7:2019-01 (p. 6.5.1) | ISO 19642-8:2019-01 (p. 6.5.1) | ISO 19642-9:2019-01 (p. 6.5.1) | ISO 19642-10:2019-01 (p. 6.5.1)","search_zh":"电缆 ISO 19642-2:2023-08 (p. 5.5.1) | ISO 19642-2:2023-08 (p. 6.5.1) | ISO 19642-3:2019-01 (p. 5.5.1) | ISO 19642-4:2019-01 (p. 5.5.1) | ISO 19642-5:2019-01 (p. 5.5.1) | ISO 19642-6:2019-01 (p. 5.5.1) | ISO 19642-7:2019-01 (p. 6.5.1) | ISO 19642-8:2019-01 (p. 6.5.1) | ISO 19642-9:2019-01 (p. 6.5.1) | ISO 19642-10:2019-01 (p. 6.5.1)","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a0ef","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Badania starzeniowe:","methodology_en":"Ageing tests:","parameters":[{"name":"długotrwałe starzenie kabla","range":"(3000 h)"},{"name":"krótkotrwałe starzenie kabla","range":"(240 h)"},{"name":"przeciążenie cieplne kabli"},{"name":"Piec","range":"do 225 °C (± 4 °C)"},{"name":"Zakres","range":"(1 – 12) kV A.C. (50, 60 Hz)"},{"name":"Zakres","range":"(1 – 16) kV D.C."},{"name":"long-term heat aging","range":"(3000 h)"},{"name":"short-term heat aging","range":"(240 h)"},{"name":"thermal overload Range: Aging oven: up to do 225 °C","range":"(± 4 °C)"},{"name":"(1 – 12) kV A.C.","range":"(50, 60 Hz)"},{"name":"(1 – 16) kV D.C"}],"parameters_en":[{"name":"long-term cable ageing","range":"(3000 h)"},{"name":"short-term cable ageing","range":"(240 h)"},{"name":"thermal overload of cables"},{"name":"Stove","range":"do 225 °C (± 4 °C)"},{"name":"Range","range":"(1 – 12) kV A.C. (50, 60 Hz)"},{"name":"Range","range":"(1 – 16) kV D.C."},{"name":"long-term heat aging","range":"(3000 h)"},{"name":"short-term heat aging","range":"(240 h)"},{"name":"thermal overload Range: Aging oven: up to do 225 °C","range":"(± 4 °C)"},{"name":"(1 – 12) kV A.C.","range":"(50, 60 Hz)"},{"name":"(1 – 16) kV D.C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania starzeniowe:\nZakres:\ndługotrwałe starzenie kabla (3000 h)\nkrótkotrwałe starzenie kabla (240 h)\nprzeciążenie cieplne kabli\nPiec do 225 °C (± 4 °C)\nZakres (1 – 12) kV A.C. (50, 60 Hz)\nZakres (1 – 16) kV D.C.\nlong-term heat aging (3000 h)\nshort-term heat aging (240 h)\nthermal overload Range: Aging oven: up to do 225 °C (± 4 °C)\n(1 – 12) kV A.C. (50, 60 Hz)\n(1 – 16) kV D.C","reference":"ISO 19642-2:2023-08 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-2:2023-08 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-3:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-4:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-5:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-6:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-7:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-8:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-9: 2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-10:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 6722-1:2011; corr.1:2012 (p. 5.13; 5.14; 5.15) | ISO 6722-2:2013 (p. 5.13; 5.14; 5.15) VW 60306-1:2021-10 (p. 9.7.6.1; 9.7.7; 9.7.8.1) VW 60306-2:2021-11 (p. 9.7.6.1; 9.7.7; 9.7.8.1) VW 60306-4:2021-12 (p. 9.7.6.1; 9.7.7; 9.7.8.1) VW 75210-1:2024-08 (p. 9.7.6.1; 9.7.7.1; 9.7.8.1) DIN/TS 70112-1:2024-03 (p. 7.8.6; 7.8.7, 7.8.8) Scope of accreditation No. AB 1814","norm_bases":["ISO 19642-2:2023-08 (p. 5.5.2; 5.5.3; 5.5.4)","ISO 19642-2:2023-08 (p. 6.5.2; 6.5.3; 6.5.4)","ISO 19642-3:2019-01 (p. 5.5.2; 5.5.3; 5.5.4)","ISO 19642-4:2019-01 (p. 5.5.2; 5.5.3; 5.5.4)","ISO 19642-5:2019-01 (p. 5.5.2; 5.5.3; 5.5.4)","ISO 19642-6:2019-01 (p. 5.5.2; 5.5.3; 5.5.4)","ISO 19642-7:2019-01 (p. 6.5.2; 6.5.3; 6.5.4)","ISO 19642-8:2019-01 (p. 6.5.2; 6.5.3; 6.5.4)","ISO 19642-9: 2019-01 (p. 6.5.2; 6.5.3; 6.5.4)","ISO 19642-10:2019-01 (p. 6.5.2; 6.5.3; 6.5.4)","ISO 6722-1:2011; corr.1:2012 (p. 5.13; 5.14; 5.15)","ISO 6722-2:2013 (p. 5.13; 5.14; 5.15) VW 60306-1:2021-10 (p. 9.7.6.1; 9.7.7; 9.7.8.1) VW 60306-2:2021-11 (p. 9.7.6.1; 9.7.7; 9.7.8.1) VW 60306-4:2021-12 (p. 9.7.6.1; 9.7.7; 9.7.8.1) VW 75210-1:2024-08 (p. 9.7.6.1; 9.7.7.1; 9.7.8.1) DIN/TS 70112-1:2024-03 (p. 7.8.6; 7.8.7, 7.8.8) Scope of accreditation No. AB 1814"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Badania starzeniowe:\nZakres:\ndługotrwałe starzenie kabla (3000 h)\nkrótkotrwałe starzenie kabla (240 h)\nprzeciążenie cieplne kabli\nPiec do 225 °C (± 4 °C)\nZakres (1 – 12) kV A.C. (50, 60 Hz)\nZakres (1 – 16) kV D.C.\nlong-term heat aging (3000 h)\nshort-term heat aging (240 h)\nthermal overload Range: Aging oven: up to do 225 °C (± 4 °C)\n(1 – 12) kV A.C. (50, 60 Hz)\n(1 – 16) kV D.C ISO 19642-2:2023-08 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-2:2023-08 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-3:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-4:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-5:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-6:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-7:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-8:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-9: 2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-10:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 6722-1:2011; corr.1:2012 (p. 5.13; 5.14; 5.15) | ISO 6722-2:2013 (p. 5.13; 5.14; 5.15) VW 60306-1:2021-10 (p. 9.7.6.1; 9.7.7; 9.7.8.1) VW 60306-2:2021-11 (p. 9.7.6.1; 9.7.7; 9.7.8.1) VW 60306-4:2021-12 (p. 9.7.6.1; 9.7.7; 9.7.8.1) VW 75210-1:2024-08 (p. 9.7.6.1; 9.7.7.1; 9.7.8.1) DIN/TS 70112-1:2024-03 (p. 7.8.6; 7.8.7, 7.8.8) Scope of accreditation No. AB 1814 Kable, Cables Badania starzeniowe:\nZakres:\ndlugotrwale starzenie kabla (3000 h)\nkrotkotrwale starzenie kabla (240 h)\nprzeciazenie cieplne kabli\nPiec do 225 °C (± 4 °C)\nZakres (1 – 12) kV A.C. (50, 60 Hz)\nZakres (1 – 16) kV D.C.\nlong-term heat aging (3000 h)\nshort-term heat aging (240 h)\nthermal overload Range: Aging oven: up to do 225 °C (± 4 °C)\n(1 – 12) kV A.C. (50, 60 Hz)\n(1 – 16) kV D.C ISO 19642-2:2023-08 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-2:2023-08 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-3:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-4:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-5:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-6:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-7:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-8:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-9: 2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-10:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 6722-1:2011; corr.1:2012 (p. 5.13; 5.14; 5.15) | ISO 6722-2:2013 (p. 5.13; 5.14; 5.15) VW 60306-1:2021-10 (p. 9.7.6.1; 9.7.7; 9.7.8.1) VW 60306-2:2021-11 (p. 9.7.6.1; 9.7.7; 9.7.8.1) VW 60306-4:2021-12 (p. 9.7.6.1; 9.7.7; 9.7.8.1) VW 75210-1:2024-08 (p. 9.7.6.1; 9.7.7.1; 9.7.8.1) DIN/TS 70112-1:2024-03 (p. 7.8.6; 7.8.7, 7.8.8) Scope of accreditation No. AB 1814","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Ageing tests: long-term cable ageing short-term cable ageing thermal overload of cables Stove Range Range long-term heat aging short-term heat aging thermal overload Range: Aging oven: up to do 225 °C (1 – 12) kV A.C. (1 – 16) kV D.C ISO 19642-2:2023-08 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-2:2023-08 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-3:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-4:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-5:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-6:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-7:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-8:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-9: 2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-10:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 6722-1:2011; corr.1:2012 (p. 5.13; 5.14; 5.15) | ISO 6722-2:2013 (p. 5.13; 5.14; 5.15) VW 60306-1:2021-10 (p. 9.7.6.1; 9.7.7; 9.7.8.1) VW 60306-2:2021-11 (p. 9.7.6.1; 9.7.7; 9.7.8.1) VW 60306-4:2021-12 (p. 9.7.6.1; 9.7.7; 9.7.8.1) VW 75210-1:2024-08 (p. 9.7.6.1; 9.7.7.1; 9.7.8.1) DIN/TS 70112-1:2024-03 (p. 7.8.6; 7.8.7, 7.8.8) Scope of accreditation No. AB 1814","parameters_zh":[{"name":"电缆长期老化","range":"(3000 h)"},{"name":"电缆短期老化","range":"(240 h)"},{"name":"电缆热过载"},{"name":"炉窑","range":"do 225 °C (± 4 °C)"},{"name":"范围","range":"(1 – 12) kV A.C. (50, 60 Hz)"},{"name":"范围","range":"(1 – 16) kV D.C."},{"name":"long-term heat aging","range":"(3000 h)"},{"name":"short-term heat aging","range":"(240 h)"},{"name":"thermal overload Range: Aging oven: up to do 225 °C","range":"(± 4 °C)"},{"name":"(1 – 12) kV A.C.","range":"(50, 60 Hz)"},{"name":"(1 – 16) kV D.C"}],"search_zh":"电缆 老化检验： 电缆长期老化 电缆短期老化 电缆热过载 炉窑 范围 范围 ISO 19642-2:2023-08 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-2:2023-08 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-3:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-4:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-5:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-6:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-7:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-8:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-9: 2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-10:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 6722-1:2011; corr.1:2012 (p. 5.13; 5.14; 5.15) | ISO 6722-2:2013 (p. 5.13; 5.14; 5.15) VW 60306-1:2021-10 (p. 9.7.6.1; 9.7.7; 9.7.8.1) VW 60306-2:2021-11 (p. 9.7.6.1; 9.7.7; 9.7.8.1) VW 60306-4:2021-12 (p. 9.7.6.1; 9.7.7; 9.7.8.1) VW 75210-1:2024-08 (p. 9.7.6.1; 9.7.7.1; 9.7.8.1) DIN/TS 70112-1:2024-03 (p. 7.8.6; 7.8.7, 7.8.8) Scope of accreditation No. AB 1814","test_object_zh":"电缆","methodology_zh":"老化检验："},{"_id":"6a5dc9aaf1c10c8ce825a0f0","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Ściągalność izolacji / powłoki kabla","methodology_en":"Strippability of cable insulation / sheath","parameters":[{"name":"Maszyna wytrzymałościowa:"},{"name":"Zakres","range":"(2 – 1000) N"},{"name":"Strip force Range:"}],"parameters_en":[{"name":"Testing machine:"},{"name":"Range","range":"(2 – 1000) N"},{"name":"Strip force Range:"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ściągalność izolacji / powłoki kabla\nZakres:\nMaszyna wytrzymałościowa:\nZakres (2 – 1000) N\nStrip force Range:","reference":"ISO 19642-2:2023-08 (p. 5.4.1) | ISO 19642-2:2023-08 (p. 6.4.1) | ISO 19642-3:2019-01 (p. 5.4.1) | ISO 19642-4:2019-01 (p. 5.4.1) | ISO 19642-5:2019-01 (p. 5.4.1) | ISO 19642-6:2019-01 (p. 5.4.1) | ISO 19642-7:2019-01 (p. 6.4.1) | ISO 19642-8:2019-01 (p. 6.4.1) | ISO 19642-9:2019-01 (p. 6.4.1) | ISO 19642-10:2019-01 (p. 6.4.1) | ISO 6722-1:2011; corr.1:2012 (p. 5.9) | ISO 6722-2:2013 (p. 5.9) VW 60306-1:2021-10 (p. 9.4.1) VW 60306-2:2021-11 (p. 9.4.1) VW 60306-4:2021-12 (p. 9.4.1) DIN/TS 70112-1:2024-03 (p. 7.6.1)","norm_bases":["ISO 19642-2:2023-08 (p. 5.4.1)","ISO 19642-2:2023-08 (p. 6.4.1)","ISO 19642-3:2019-01 (p. 5.4.1)","ISO 19642-4:2019-01 (p. 5.4.1)","ISO 19642-5:2019-01 (p. 5.4.1)","ISO 19642-6:2019-01 (p. 5.4.1)","ISO 19642-7:2019-01 (p. 6.4.1)","ISO 19642-8:2019-01 (p. 6.4.1)","ISO 19642-9:2019-01 (p. 6.4.1)","ISO 19642-10:2019-01 (p. 6.4.1)","ISO 6722-1:2011; corr.1:2012 (p. 5.9)","ISO 6722-2:2013 (p. 5.9) VW 60306-1:2021-10 (p. 9.4.1) VW 60306-2:2021-11 (p. 9.4.1) VW 60306-4:2021-12 (p. 9.4.1) DIN/TS 70112-1:2024-03 (p. 7.6.1)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Ściągalność izolacji / powłoki kabla\nZakres:\nMaszyna wytrzymałościowa:\nZakres (2 – 1000) N\nStrip force Range: ISO 19642-2:2023-08 (p. 5.4.1) | ISO 19642-2:2023-08 (p. 6.4.1) | ISO 19642-3:2019-01 (p. 5.4.1) | ISO 19642-4:2019-01 (p. 5.4.1) | ISO 19642-5:2019-01 (p. 5.4.1) | ISO 19642-6:2019-01 (p. 5.4.1) | ISO 19642-7:2019-01 (p. 6.4.1) | ISO 19642-8:2019-01 (p. 6.4.1) | ISO 19642-9:2019-01 (p. 6.4.1) | ISO 19642-10:2019-01 (p. 6.4.1) | ISO 6722-1:2011; corr.1:2012 (p. 5.9) | ISO 6722-2:2013 (p. 5.9) VW 60306-1:2021-10 (p. 9.4.1) VW 60306-2:2021-11 (p. 9.4.1) VW 60306-4:2021-12 (p. 9.4.1) DIN/TS 70112-1:2024-03 (p. 7.6.1) Kable, Cables Sciagalnosc izolacji / powloki kabla\nZakres:\nMaszyna wytrzymalosciowa:\nZakres (2 – 1000) N\nStrip force Range: ISO 19642-2:2023-08 (p. 5.4.1) | ISO 19642-2:2023-08 (p. 6.4.1) | ISO 19642-3:2019-01 (p. 5.4.1) | ISO 19642-4:2019-01 (p. 5.4.1) | ISO 19642-5:2019-01 (p. 5.4.1) | ISO 19642-6:2019-01 (p. 5.4.1) | ISO 19642-7:2019-01 (p. 6.4.1) | ISO 19642-8:2019-01 (p. 6.4.1) | ISO 19642-9:2019-01 (p. 6.4.1) | ISO 19642-10:2019-01 (p. 6.4.1) | ISO 6722-1:2011; corr.1:2012 (p. 5.9) | ISO 6722-2:2013 (p. 5.9) VW 60306-1:2021-10 (p. 9.4.1) VW 60306-2:2021-11 (p. 9.4.1) VW 60306-4:2021-12 (p. 9.4.1) DIN/TS 70112-1:2024-03 (p. 7.6.1)","categories":["construction"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Strippability of cable insulation / sheath Testing machine: Range Strip force Range: ISO 19642-2:2023-08 (p. 5.4.1) | ISO 19642-2:2023-08 (p. 6.4.1) | ISO 19642-3:2019-01 (p. 5.4.1) | ISO 19642-4:2019-01 (p. 5.4.1) | ISO 19642-5:2019-01 (p. 5.4.1) | ISO 19642-6:2019-01 (p. 5.4.1) | ISO 19642-7:2019-01 (p. 6.4.1) | ISO 19642-8:2019-01 (p. 6.4.1) | ISO 19642-9:2019-01 (p. 6.4.1) | ISO 19642-10:2019-01 (p. 6.4.1) | ISO 6722-1:2011; corr.1:2012 (p. 5.9) | ISO 6722-2:2013 (p. 5.9) VW 60306-1:2021-10 (p. 9.4.1) VW 60306-2:2021-11 (p. 9.4.1) VW 60306-4:2021-12 (p. 9.4.1) DIN/TS 70112-1:2024-03 (p. 7.6.1)","parameters_zh":[{"name":"材料试验机："},{"name":"范围","range":"(2 – 1000) N"},{"name":"Strip force Range:"}],"search_zh":"电缆 材料试验机： 范围 ISO 19642-2:2023-08 (p. 5.4.1) | ISO 19642-2:2023-08 (p. 6.4.1) | ISO 19642-3:2019-01 (p. 5.4.1) | ISO 19642-4:2019-01 (p. 5.4.1) | ISO 19642-5:2019-01 (p. 5.4.1) | ISO 19642-6:2019-01 (p. 5.4.1) | ISO 19642-7:2019-01 (p. 6.4.1) | ISO 19642-8:2019-01 (p. 6.4.1) | ISO 19642-9:2019-01 (p. 6.4.1) | ISO 19642-10:2019-01 (p. 6.4.1) | ISO 6722-1:2011; corr.1:2012 (p. 5.9) | ISO 6722-2:2013 (p. 5.9) VW 60306-1:2021-10 (p. 9.4.1) VW 60306-2:2021-11 (p. 9.4.1) VW 60306-4:2021-12 (p. 9.4.1) DIN/TS 70112-1:2024-03 (p. 7.6.1)","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a0f1","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Nawijanie kabla w niskiej temperaturze","methodology_en":"Cable winding at low temperature","parameters":[{"name":"Komora klimatyczna:"},{"name":"40 °C do 85 °C","range":"(± 2 °C)"},{"name":"Zakres","range":"(1 – 12) kV A.C. (50, 60Hz)"},{"name":"Zakres","range":"(1 – 16) kV D.C."},{"name":"Range:"},{"name":"40 °C do 85 °C","range":"(± 2 °C)"},{"name":"(1 – 12) kV A.C.","range":"(50, 60Hz)"},{"name":"(1 – 16) kV D.C."}],"parameters_en":[{"name":"Climatic chamber:"},{"name":"40 °C to 85 °C","range":"(± 2 °C)"},{"name":"Range","range":"(1 – 12) kV A.C. (50, 60Hz)"},{"name":"Range","range":"(1 – 16) kV D.C."},{"name":"Range:"},{"name":"40 °C to 85 °C","range":"(± 2 °C)"},{"name":"(1 – 12) kV A.C.","range":"(50, 60Hz)"},{"name":"(1 – 16) kV D.C."}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Nawijanie kabla w niskiej temperaturze\nZakres:\nKomora klimatyczna:\n40 °C do 85 °C (± 2 °C)\nZakres (1 – 12) kV A.C. (50, 60Hz)\nZakres (1 – 16) kV D.C.\nRange:\n40 °C do 85 °C (± 2 °C)\n(1 – 12) kV A.C. (50, 60Hz)\n(1 – 16) kV D.C.","reference":"ISO 19642-2:2023-08 (p. 5.5.7) | ISO 19642-2:2023-08 (p. 6.5.7) | ISO 19642-3:2019-01 (p. 5.5.7) | ISO 19642-4:2019-01 (p. 5.5.7) | ISO 19642-5:2019-01 (p. 5.5.7) | ISO 19642-6:2019-01 (p. 5.5.7) | ISO 19642-7:2019-01 (p. 6.5.7) | ISO 19642-8:2019-01 (p. 6.5.7) | ISO 19642-9:2019-01 (p. 6.5.7) | ISO 19642-10:2019-01 (p. 6.5.7) | ISO 6722-1:2011; corr.1:2012 (p. 5.10) | ISO 6722-2:2013 (p. 5.10) VW 60306-1:2021-10 (p. 9.7.9) VW 60306-2:2021-11 (p. 9.7.9) VW 60306-4:2021-12 (p. 9.7.9) DIN/TS 70112-1:2024-03 (p. 7.8.10)","norm_bases":["ISO 19642-2:2023-08 (p. 5.5.7)","ISO 19642-2:2023-08 (p. 6.5.7)","ISO 19642-3:2019-01 (p. 5.5.7)","ISO 19642-4:2019-01 (p. 5.5.7)","ISO 19642-5:2019-01 (p. 5.5.7)","ISO 19642-6:2019-01 (p. 5.5.7)","ISO 19642-7:2019-01 (p. 6.5.7)","ISO 19642-8:2019-01 (p. 6.5.7)","ISO 19642-9:2019-01 (p. 6.5.7)","ISO 19642-10:2019-01 (p. 6.5.7)","ISO 6722-1:2011; corr.1:2012 (p. 5.10)","ISO 6722-2:2013 (p. 5.10) VW 60306-1:2021-10 (p. 9.7.9) VW 60306-2:2021-11 (p. 9.7.9) VW 60306-4:2021-12 (p. 9.7.9) DIN/TS 70112-1:2024-03 (p. 7.8.10)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Nawijanie kabla w niskiej temperaturze\nZakres:\nKomora klimatyczna:\n40 °C do 85 °C (± 2 °C)\nZakres (1 – 12) kV A.C. (50, 60Hz)\nZakres (1 – 16) kV D.C.\nRange:\n40 °C do 85 °C (± 2 °C)\n(1 – 12) kV A.C. (50, 60Hz)\n(1 – 16) kV D.C. ISO 19642-2:2023-08 (p. 5.5.7) | ISO 19642-2:2023-08 (p. 6.5.7) | ISO 19642-3:2019-01 (p. 5.5.7) | ISO 19642-4:2019-01 (p. 5.5.7) | ISO 19642-5:2019-01 (p. 5.5.7) | ISO 19642-6:2019-01 (p. 5.5.7) | ISO 19642-7:2019-01 (p. 6.5.7) | ISO 19642-8:2019-01 (p. 6.5.7) | ISO 19642-9:2019-01 (p. 6.5.7) | ISO 19642-10:2019-01 (p. 6.5.7) | ISO 6722-1:2011; corr.1:2012 (p. 5.10) | ISO 6722-2:2013 (p. 5.10) VW 60306-1:2021-10 (p. 9.7.9) VW 60306-2:2021-11 (p. 9.7.9) VW 60306-4:2021-12 (p. 9.7.9) DIN/TS 70112-1:2024-03 (p. 7.8.10) Kable, Cables Nawijanie kabla w niskiej temperaturze\nZakres:\nKomora klimatyczna:\n40 °C do 85 °C (± 2 °C)\nZakres (1 – 12) kV A.C. (50, 60Hz)\nZakres (1 – 16) kV D.C.\nRange:\n40 °C do 85 °C (± 2 °C)\n(1 – 12) kV A.C. (50, 60Hz)\n(1 – 16) kV D.C. ISO 19642-2:2023-08 (p. 5.5.7) | ISO 19642-2:2023-08 (p. 6.5.7) | ISO 19642-3:2019-01 (p. 5.5.7) | ISO 19642-4:2019-01 (p. 5.5.7) | ISO 19642-5:2019-01 (p. 5.5.7) | ISO 19642-6:2019-01 (p. 5.5.7) | ISO 19642-7:2019-01 (p. 6.5.7) | ISO 19642-8:2019-01 (p. 6.5.7) | ISO 19642-9:2019-01 (p. 6.5.7) | ISO 19642-10:2019-01 (p. 6.5.7) | ISO 6722-1:2011; corr.1:2012 (p. 5.10) | ISO 6722-2:2013 (p. 5.10) VW 60306-1:2021-10 (p. 9.7.9) VW 60306-2:2021-11 (p. 9.7.9) VW 60306-4:2021-12 (p. 9.7.9) DIN/TS 70112-1:2024-03 (p. 7.8.10)","categories":["other"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Cable winding at low temperature Climatic chamber: 40 °C to 85 °C Range Range Range: 40 °C to 85 °C (1 – 12) kV A.C. (1 – 16) kV D.C. ISO 19642-2:2023-08 (p. 5.5.7) | ISO 19642-2:2023-08 (p. 6.5.7) | ISO 19642-3:2019-01 (p. 5.5.7) | ISO 19642-4:2019-01 (p. 5.5.7) | ISO 19642-5:2019-01 (p. 5.5.7) | ISO 19642-6:2019-01 (p. 5.5.7) | ISO 19642-7:2019-01 (p. 6.5.7) | ISO 19642-8:2019-01 (p. 6.5.7) | ISO 19642-9:2019-01 (p. 6.5.7) | ISO 19642-10:2019-01 (p. 6.5.7) | ISO 6722-1:2011; corr.1:2012 (p. 5.10) | ISO 6722-2:2013 (p. 5.10) VW 60306-1:2021-10 (p. 9.7.9) VW 60306-2:2021-11 (p. 9.7.9) VW 60306-4:2021-12 (p. 9.7.9) DIN/TS 70112-1:2024-03 (p. 7.8.10)","parameters_zh":[{"name":"Komora klimatyczna:"},{"name":"40 °C do 85 °C","range":"(± 2 °C)"},{"name":"范围","range":"(1 – 12) kV A.C. (50, 60Hz)"},{"name":"范围","range":"(1 – 16) kV D.C."},{"name":"Range:"},{"name":"40 °C do 85 °C","range":"(± 2 °C)"},{"name":"(1 – 12) kV A.C.","range":"(50, 60Hz)"},{"name":"(1 – 16) kV D.C."}],"search_zh":"电缆 范围 范围 ISO 19642-2:2023-08 (p. 5.5.7) | ISO 19642-2:2023-08 (p. 6.5.7) | ISO 19642-3:2019-01 (p. 5.5.7) | ISO 19642-4:2019-01 (p. 5.5.7) | ISO 19642-5:2019-01 (p. 5.5.7) | ISO 19642-6:2019-01 (p. 5.5.7) | ISO 19642-7:2019-01 (p. 6.5.7) | ISO 19642-8:2019-01 (p. 6.5.7) | ISO 19642-9:2019-01 (p. 6.5.7) | ISO 19642-10:2019-01 (p. 6.5.7) | ISO 6722-1:2011; corr.1:2012 (p. 5.10) | ISO 6722-2:2013 (p. 5.10) VW 60306-1:2021-10 (p. 9.7.9) VW 60306-2:2021-11 (p. 9.7.9) VW 60306-4:2021-12 (p. 9.7.9) DIN/TS 70112-1:2024-03 (p. 7.8.10)","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a0f2","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Owalność kabla","methodology_en":"Cable ovality","parameters":[{"name":"Średnica zewnętrzna kabla","range":"do 25 mm"},{"name":"Ovality Range:"}],"parameters_en":[{"name":"Cable outer diameter","range":"do 25 mm"},{"name":"Ovality Range:"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Owalność kabla\nZakres:\nŚrednica zewnętrzna kabla do 25 mm\nOvality Range:","reference":"ISO 19642-2:2023-08 (p. 6.2.2) | ISO 19642-7:2019-01 (p. 6.2.2) | ISO 19642-8 2019-01 (p. 6.2.2) | ISO 19642-9:2019-01 (p. 6.2.2) | ISO 19642-10:2019-01 (p. 6.2.2)","norm_bases":["ISO 19642-2:2023-08 (p. 6.2.2)","ISO 19642-7:2019-01 (p. 6.2.2)","ISO 19642-8 2019-01 (p. 6.2.2)","ISO 19642-9:2019-01 (p. 6.2.2)","ISO 19642-10:2019-01 (p. 6.2.2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Owalność kabla\nZakres:\nŚrednica zewnętrzna kabla do 25 mm\nOvality Range: ISO 19642-2:2023-08 (p. 6.2.2) | ISO 19642-7:2019-01 (p. 6.2.2) | ISO 19642-8 2019-01 (p. 6.2.2) | ISO 19642-9:2019-01 (p. 6.2.2) | ISO 19642-10:2019-01 (p. 6.2.2) Kable, Cables Owalnosc kabla\nZakres:\nSrednica zewnetrzna kabla do 25 mm\nOvality Range: ISO 19642-2:2023-08 (p. 6.2.2) | ISO 19642-7:2019-01 (p. 6.2.2) | ISO 19642-8 2019-01 (p. 6.2.2) | ISO 19642-9:2019-01 (p. 6.2.2) | ISO 19642-10:2019-01 (p. 6.2.2)","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Cable ovality Cable outer diameter Ovality Range: ISO 19642-2:2023-08 (p. 6.2.2) | ISO 19642-7:2019-01 (p. 6.2.2) | ISO 19642-8 2019-01 (p. 6.2.2) | ISO 19642-9:2019-01 (p. 6.2.2) | ISO 19642-10:2019-01 (p. 6.2.2)","search_zh":"电缆 ISO 19642-2:2023-08 (p. 6.2.2) | ISO 19642-7:2019-01 (p. 6.2.2) | ISO 19642-8 2019-01 (p. 6.2.2) | ISO 19642-9:2019-01 (p. 6.2.2) | ISO 19642-10:2019-01 (p. 6.2.2)","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a0f3","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Wskaźnik ściągalności izolacji (A-faktor/Sfaktor), Insulation strippability factor (A-factor)","methodology_en":"Insulation strippability factor (A-factor)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik ściągalności izolacji (A-faktor/Sfaktor), Insulation strippability factor (A-factor)","reference":"VW 60306-1:2021-10 (p. 9.2.5) | ISO 19642-2:2023-08 (Annex D) DIN/TS 70112-1:2024-03 (p. 7.4.5) Scope of accreditation No. AB 1814","norm_bases":["VW 60306-1:2021-10 (p. 9.2.5)","ISO 19642-2:2023-08 (Annex D) DIN/TS 70112-1:2024-03 (p. 7.4.5) Scope of accreditation No. AB 1814"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Wskaźnik ściągalności izolacji (A-faktor/Sfaktor), Insulation strippability factor (A-factor) VW 60306-1:2021-10 (p. 9.2.5) | ISO 19642-2:2023-08 (Annex D) DIN/TS 70112-1:2024-03 (p. 7.4.5) Scope of accreditation No. AB 1814 Kable, Cables Wskaznik sciagalnosci izolacji (A-faktor/Sfaktor), Insulation strippability factor (A-factor) VW 60306-1:2021-10 (p. 9.2.5) | ISO 19642-2:2023-08 (Annex D) DIN/TS 70112-1:2024-03 (p. 7.4.5) Scope of accreditation No. AB 1814","categories":["construction"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Insulation strippability factor (A-factor) VW 60306-1:2021-10 (p. 9.2.5) | ISO 19642-2:2023-08 (Annex D) DIN/TS 70112-1:2024-03 (p. 7.4.5) Scope of accreditation No. AB 1814","search_zh":"电缆 VW 60306-1:2021-10 (p. 9.2.5) | ISO 19642-2:2023-08 (Annex D) DIN/TS 70112-1:2024-03 (p. 7.4.5) Scope of accreditation No. AB 1814","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a0f4","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Określenie wytrzymałości na rozciąganie i wydłużenie przy zrywaniu:","methodology_en":"Determination of tensile strength and elongation at break:","parameters":[{"name":"w temperaturze pokojowej"},{"name":"po krótkotrwałym starzeniu"},{"name":"po długotrwałym starzeniu Maszyna wytrzymałościowa:"},{"name":"Zakres","range":"(0,2 – 2500) N"},{"name":"Ekstensometr","range":"(20 – 500) mm"}],"parameters_en":[{"name":"at room temperature"},{"name":"after short-term ageing"},{"name":"after long-term ageing Testing machine:"},{"name":"Range","range":"(0,2 – 2500) N"},{"name":"Extensometer","range":"(20 – 500) mm"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Określenie wytrzymałości na rozciąganie i wydłużenie przy zrywaniu:\nZakres:\nw temperaturze pokojowej\npo krótkotrwałym starzeniu\npo długotrwałym starzeniu Maszyna wytrzymałościowa:\nZakres (0,2 – 2500) N\nEkstensometr (20 – 500) mm","reference":"IEC 60811-401:2012-03+A1:2017 | IEC 60811-501:2012+AMD1:2018 +AMD2:2023 VW 60306-1:2021-10 (p. 9.3.4) VW 60306-2:2021-11 (p. 9.3.4) VW 60306-4:2021-12 (p. 9.3.4) VW 75210-1:2019-06 (p. 9.2.3) VW 75210-1:2024-08 (p. 9.3.5) DIN/TS 70112-1:2024-03 (p. 7.5.5)","norm_bases":["IEC 60811-401:2012-03+A1:2017","IEC 60811-501:2012+AMD1:2018 +AMD2:2023 VW 60306-1:2021-10 (p. 9.3.4) VW 60306-2:2021-11 (p. 9.3.4) VW 60306-4:2021-12 (p. 9.3.4) VW 75210-1:2019-06 (p. 9.2.3) VW 75210-1:2024-08 (p. 9.3.5) DIN/TS 70112-1:2024-03 (p. 7.5.5)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Określenie wytrzymałości na rozciąganie i wydłużenie przy zrywaniu:\nZakres:\nw temperaturze pokojowej\npo krótkotrwałym starzeniu\npo długotrwałym starzeniu Maszyna wytrzymałościowa:\nZakres (0,2 – 2500) N\nEkstensometr (20 – 500) mm IEC 60811-401:2012-03+A1:2017 | IEC 60811-501:2012+AMD1:2018 +AMD2:2023 VW 60306-1:2021-10 (p. 9.3.4) VW 60306-2:2021-11 (p. 9.3.4) VW 60306-4:2021-12 (p. 9.3.4) VW 75210-1:2019-06 (p. 9.2.3) VW 75210-1:2024-08 (p. 9.3.5) DIN/TS 70112-1:2024-03 (p. 7.5.5) Kable, Cables Okreslenie wytrzymalosci na rozciaganie i wydluzenie przy zrywaniu:\nZakres:\nw temperaturze pokojowej\npo krotkotrwalym starzeniu\npo dlugotrwalym starzeniu Maszyna wytrzymalosciowa:\nZakres (0,2 – 2500) N\nEkstensometr (20 – 500) mm IEC 60811-401:2012-03+A1:2017 | IEC 60811-501:2012+AMD1:2018 +AMD2:2023 VW 60306-1:2021-10 (p. 9.3.4) VW 60306-2:2021-11 (p. 9.3.4) VW 60306-4:2021-12 (p. 9.3.4) VW 75210-1:2019-06 (p. 9.2.3) VW 75210-1:2024-08 (p. 9.3.5) DIN/TS 70112-1:2024-03 (p. 7.5.5)","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Determination of tensile strength and elongation at break: at room temperature after short-term ageing after long-term ageing Testing machine: Range Extensometer IEC 60811-401:2012-03+A1:2017 | IEC 60811-501:2012+AMD1:2018 +AMD2:2023 VW 60306-1:2021-10 (p. 9.3.4) VW 60306-2:2021-11 (p. 9.3.4) VW 60306-4:2021-12 (p. 9.3.4) VW 75210-1:2019-06 (p. 9.2.3) VW 75210-1:2024-08 (p. 9.3.5) DIN/TS 70112-1:2024-03 (p. 7.5.5)","parameters_zh":[{"name":"室温下"},{"name":"po krótkotrwałym starzeniu"},{"name":"po długotrwałym starzeniu Maszyna wytrzymałościowa:"},{"name":"范围","range":"(0,2 – 2500) N"},{"name":"引伸计","range":"(20 – 500) mm"}],"search_zh":"电缆 室温下 范围 引伸计 IEC 60811-401:2012-03+A1:2017 | IEC 60811-501:2012+AMD1:2018 +AMD2:2023 VW 60306-1:2021-10 (p. 9.3.4) VW 60306-2:2021-11 (p. 9.3.4) VW 60306-4:2021-12 (p. 9.3.4) VW 75210-1:2019-06 (p. 9.2.3) VW 75210-1:2024-08 (p. 9.3.5) DIN/TS 70112-1:2024-03 (p. 7.5.5)","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a0f5","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Odporność izolacji / powłoki kabla na nacisk w wysokiej temperaturze","methodology_en":"Resistance of cable insulation / sheath to pressure at high temperature","parameters":[{"name":"Piec","range":"do 225 °C (± 4 °C)"},{"name":"Zakres","range":"(1 – 12) kV A.C. (50, 60 Hz)"},{"name":"1 – 16) kV D.C."}],"parameters_en":[{"name":"Stove","range":"do 225 °C (± 4 °C)"},{"name":"Range","range":"(1 – 12) kV A.C. (50, 60 Hz)"},{"name":"1 – 16) kV D.C."}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność izolacji / powłoki kabla na nacisk w wysokiej temperaturze\nZakres:\nPiec do 225 °C (± 4 °C)\nZakres (1 – 12) kV A.C. (50, 60 Hz)\n1 – 16) kV D.C.","reference":"ISO 19642-2:2023-08 (p. 5.5.5) | ISO 19642-3:2019-01 (p. 5.5.5) | ISO 19642-4:2019-01 (p. 5.5.5) | ISO 19642-5:2019-01 (p. 5.5.5) | ISO 19642-6:2019-01 (p. 5.5.5) | ISO 6722-1:2011; corr.1:2012 (p. 5.8) | ISO 6722-2:2013 (p. 5.8) VW 60306-1:2021-10 (p. 9.7.3) VW 60306-2:2021-11 (p. 9.7.3) VW 60306-4:2021-12 (p. 9.7.3) VW 75210-1:2024-08 (p. 9.7.3) VW 75210-2:2019-12 (p. 9.6.3) DIN/TS 70112-1:2024-03 (p. 7.8.3)","norm_bases":["ISO 19642-2:2023-08 (p. 5.5.5)","ISO 19642-3:2019-01 (p. 5.5.5)","ISO 19642-4:2019-01 (p. 5.5.5)","ISO 19642-5:2019-01 (p. 5.5.5)","ISO 19642-6:2019-01 (p. 5.5.5)","ISO 6722-1:2011; corr.1:2012 (p. 5.8)","ISO 6722-2:2013 (p. 5.8) VW 60306-1:2021-10 (p. 9.7.3) VW 60306-2:2021-11 (p. 9.7.3) VW 60306-4:2021-12 (p. 9.7.3) VW 75210-1:2024-08 (p. 9.7.3) VW 75210-2:2019-12 (p. 9.6.3) DIN/TS 70112-1:2024-03 (p. 7.8.3)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Odporność izolacji / powłoki kabla na nacisk w wysokiej temperaturze\nZakres:\nPiec do 225 °C (± 4 °C)\nZakres (1 – 12) kV A.C. (50, 60 Hz)\n1 – 16) kV D.C. ISO 19642-2:2023-08 (p. 5.5.5) | ISO 19642-3:2019-01 (p. 5.5.5) | ISO 19642-4:2019-01 (p. 5.5.5) | ISO 19642-5:2019-01 (p. 5.5.5) | ISO 19642-6:2019-01 (p. 5.5.5) | ISO 6722-1:2011; corr.1:2012 (p. 5.8) | ISO 6722-2:2013 (p. 5.8) VW 60306-1:2021-10 (p. 9.7.3) VW 60306-2:2021-11 (p. 9.7.3) VW 60306-4:2021-12 (p. 9.7.3) VW 75210-1:2024-08 (p. 9.7.3) VW 75210-2:2019-12 (p. 9.6.3) DIN/TS 70112-1:2024-03 (p. 7.8.3) Kable, Cables Odpornosc izolacji / powloki kabla na nacisk w wysokiej temperaturze\nZakres:\nPiec do 225 °C (± 4 °C)\nZakres (1 – 12) kV A.C. (50, 60 Hz)\n1 – 16) kV D.C. ISO 19642-2:2023-08 (p. 5.5.5) | ISO 19642-3:2019-01 (p. 5.5.5) | ISO 19642-4:2019-01 (p. 5.5.5) | ISO 19642-5:2019-01 (p. 5.5.5) | ISO 19642-6:2019-01 (p. 5.5.5) | ISO 6722-1:2011; corr.1:2012 (p. 5.8) | ISO 6722-2:2013 (p. 5.8) VW 60306-1:2021-10 (p. 9.7.3) VW 60306-2:2021-11 (p. 9.7.3) VW 60306-4:2021-12 (p. 9.7.3) VW 75210-1:2024-08 (p. 9.7.3) VW 75210-2:2019-12 (p. 9.6.3) DIN/TS 70112-1:2024-03 (p. 7.8.3)","categories":["construction"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Resistance of cable insulation / sheath to pressure at high temperature Stove Range 1 – 16) kV D.C. ISO 19642-2:2023-08 (p. 5.5.5) | ISO 19642-3:2019-01 (p. 5.5.5) | ISO 19642-4:2019-01 (p. 5.5.5) | ISO 19642-5:2019-01 (p. 5.5.5) | ISO 19642-6:2019-01 (p. 5.5.5) | ISO 6722-1:2011; corr.1:2012 (p. 5.8) | ISO 6722-2:2013 (p. 5.8) VW 60306-1:2021-10 (p. 9.7.3) VW 60306-2:2021-11 (p. 9.7.3) VW 60306-4:2021-12 (p. 9.7.3) VW 75210-1:2024-08 (p. 9.7.3) VW 75210-2:2019-12 (p. 9.6.3) DIN/TS 70112-1:2024-03 (p. 7.8.3)","parameters_zh":[{"name":"炉窑","range":"do 225 °C (± 4 °C)"},{"name":"范围","range":"(1 – 12) kV A.C. (50, 60 Hz)"},{"name":"1 – 16) kV D.C."}],"search_zh":"电缆 炉窑 范围 ISO 19642-2:2023-08 (p. 5.5.5) | ISO 19642-3:2019-01 (p. 5.5.5) | ISO 19642-4:2019-01 (p. 5.5.5) | ISO 19642-5:2019-01 (p. 5.5.5) | ISO 19642-6:2019-01 (p. 5.5.5) | ISO 6722-1:2011; corr.1:2012 (p. 5.8) | ISO 6722-2:2013 (p. 5.8) VW 60306-1:2021-10 (p. 9.7.3) VW 60306-2:2021-11 (p. 9.7.3) VW 60306-4:2021-12 (p. 9.7.3) VW 75210-1:2024-08 (p. 9.7.3) VW 75210-2:2019-12 (p. 9.6.3) DIN/TS 70112-1:2024-03 (p. 7.8.3)","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a0f6","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Gumy i wyroby gumowe","test_object_en":"Rubbers and rubber products","methodology":"Określenie wytrzymałości na rozciąganie i wydłużenie przy zrywaniu","methodology_en":"Determination of tensile strength and elongation at break","parameters":[{"name":"Próbki typ 2: wiosełka Maszyna wytrzymałościowa:"},{"name":"Zakres","range":"(0,2 - 2500) N"},{"name":"Ekstensometr","range":"(20 – 500) mm"}],"parameters_en":[{"name":"Specimens type 2: dumb-bells Testing machine:"},{"name":"Range","range":"(0,2 - 2500) N"},{"name":"Extensometer","range":"(20 – 500) mm"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Określenie wytrzymałości na rozciąganie i wydłużenie przy zrywaniu\nZakres:\nPróbki typ 2: wiosełka Maszyna wytrzymałościowa:\nZakres (0,2 - 2500) N\nEkstensometr (20 – 500) mm","reference":"ISO 37:2017-11","norm_bases":["ISO 37:2017-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gumy i wyroby gumowe Określenie wytrzymałości na rozciąganie i wydłużenie przy zrywaniu\nZakres:\nPróbki typ 2: wiosełka Maszyna wytrzymałościowa:\nZakres (0,2 - 2500) N\nEkstensometr (20 – 500) mm ISO 37:2017-11 Gumy i wyroby gumowe Okreslenie wytrzymalosci na rozciaganie i wydluzenie przy zrywaniu\nZakres:\nProbki typ 2: wioselka Maszyna wytrzymalosciowa:\nZakres (0,2 - 2500) N\nEkstensometr (20 – 500) mm ISO 37:2017-11","categories":["other"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rubbers and rubber products Determination of tensile strength and elongation at break Specimens type 2: dumb-bells Testing machine: Range Extensometer ISO 37:2017-11","parameters_zh":[{"name":"Próbki typ 2: wiosełka Maszyna wytrzymałościowa:"},{"name":"范围","range":"(0,2 - 2500) N"},{"name":"引伸计","range":"(20 – 500) mm"}],"search_zh":"范围 引伸计 ISO 37:2017-11"},{"_id":"6a5dc9aaf1c10c8ce825a0f7","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Odporność izolacji / powłoki kabla na nacięcie","methodology_en":"Resistance of the cable insulation / sheath to notching","parameters":[{"name":"Maszyna wytrzymałościowa:"},{"name":"Zakres","range":"(0,2 – 2500) N"}],"parameters_en":[{"name":"Testing machine:"},{"name":"Range","range":"(0,2 – 2500) N"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność izolacji / powłoki kabla na nacięcie\nZakres:\nMaszyna wytrzymałościowa:\nZakres (0,2 – 2500) N","reference":"VW 60306-1:2021-10 (p. 9.4.4) VW 60306-2:2021-11 (p. 9.4.4) VW 60306-4:2021-12 (p. 9.4.4) VW 75210-1:2024-08 (p. 9.4.4) VW 75210-2:2019-12 (p. 9.3.4) LV 112-1:2014-04 (p. 9.3.5) DIN/TS 70112-1:2024-03 (p. 7.6.4) Scope of accreditation No. AB 1814","norm_bases":["VW 60306-1:2021-10 (p. 9.4.4) VW 60306-2:2021-11 (p. 9.4.4) VW 60306-4:2021-12 (p. 9.4.4) VW 75210-1:2024-08 (p. 9.4.4) VW 75210-2:2019-12 (p. 9.3.4) LV 112-1:2014-04 (p. 9.3.5) DIN/TS 70112-1:2024-03 (p. 7.6.4) Scope of accreditation No. AB 1814"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Odporność izolacji / powłoki kabla na nacięcie\nZakres:\nMaszyna wytrzymałościowa:\nZakres (0,2 – 2500) N VW 60306-1:2021-10 (p. 9.4.4) VW 60306-2:2021-11 (p. 9.4.4) VW 60306-4:2021-12 (p. 9.4.4) VW 75210-1:2024-08 (p. 9.4.4) VW 75210-2:2019-12 (p. 9.3.4) LV 112-1:2014-04 (p. 9.3.5) DIN/TS 70112-1:2024-03 (p. 7.6.4) Scope of accreditation No. AB 1814 Kable, Cables Odpornosc izolacji / powloki kabla na naciecie\nZakres:\nMaszyna wytrzymalosciowa:\nZakres (0,2 – 2500) N VW 60306-1:2021-10 (p. 9.4.4) VW 60306-2:2021-11 (p. 9.4.4) VW 60306-4:2021-12 (p. 9.4.4) VW 75210-1:2024-08 (p. 9.4.4) VW 75210-2:2019-12 (p. 9.3.4) LV 112-1:2014-04 (p. 9.3.5) DIN/TS 70112-1:2024-03 (p. 7.6.4) Scope of accreditation No. AB 1814","categories":["construction"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Resistance of the cable insulation / sheath to notching Testing machine: Range VW 60306-1:2021-10 (p. 9.4.4) VW 60306-2:2021-11 (p. 9.4.4) VW 60306-4:2021-12 (p. 9.4.4) VW 75210-1:2024-08 (p. 9.4.4) VW 75210-2:2019-12 (p. 9.3.4) LV 112-1:2014-04 (p. 9.3.5) DIN/TS 70112-1:2024-03 (p. 7.6.4) Scope of accreditation No. AB 1814","parameters_zh":[{"name":"材料试验机："},{"name":"范围","range":"(0,2 – 2500) N"}],"search_zh":"电缆 材料试验机： 范围 VW 60306-1:2021-10 (p. 9.4.4) VW 60306-2:2021-11 (p. 9.4.4) VW 60306-4:2021-12 (p. 9.4.4) VW 75210-1:2024-08 (p. 9.4.4) VW 75210-2:2019-12 (p. 9.3.4) LV 112-1:2014-04 (p. 9.3.5) DIN/TS 70112-1:2024-03 (p. 7.6.4) Scope of accreditation No. AB 1814","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a0f8","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Możliwość ściągania izolacji","methodology_en":"Insulation strippability","parameters":[{"name":"Nominalne pole przekroju przewodnika"},{"name":"Zakres","range":"(0,09 - 6,0) mm2"},{"name":"Insulation stripping capability Range: Nominal cross-sectional area","range":"(0,09 - 6,0) mm2"}],"parameters_en":[{"name":"Nominal cross-sectional area of the conductor"},{"name":"Range","range":"(0,09 - 6,0) mm2"},{"name":"Insulation stripping capability Range: Nominal cross-sectional area","range":"(0,09 - 6,0) mm2"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Możliwość ściągania izolacji\nZakres:\nNominalne pole przekroju przewodnika\nZakres (0,09 - 6,0) mm2\nInsulation stripping capability Range: Nominal cross-sectional area (0,09 - 6,0) mm2","reference":"VW 60306-1:2021-10 (p. 9.4.1) VW 60306-2:2021-11 (p. 9.4.1) VW 60306-4:2021-12 (p. 9.4.1) VW 75210-1:2024-08 (p. 9.4.1)","norm_bases":["VW 60306-1:2021-10 (p. 9.4.1) VW 60306-2:2021-11 (p. 9.4.1) VW 60306-4:2021-12 (p. 9.4.1) VW 75210-1:2024-08 (p. 9.4.1)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Możliwość ściągania izolacji\nZakres:\nNominalne pole przekroju przewodnika\nZakres (0,09 - 6,0) mm2\nInsulation stripping capability Range: Nominal cross-sectional area (0,09 - 6,0) mm2 VW 60306-1:2021-10 (p. 9.4.1) VW 60306-2:2021-11 (p. 9.4.1) VW 60306-4:2021-12 (p. 9.4.1) VW 75210-1:2024-08 (p. 9.4.1) Kable, Cables Mozliwosc sciagania izolacji\nZakres:\nNominalne pole przekroju przewodnika\nZakres (0,09 - 6,0) mm2\nInsulation stripping capability Range: Nominal cross-sectional area (0,09 - 6,0) mm2 VW 60306-1:2021-10 (p. 9.4.1) VW 60306-2:2021-11 (p. 9.4.1) VW 60306-4:2021-12 (p. 9.4.1) VW 75210-1:2024-08 (p. 9.4.1)","categories":["construction"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Insulation strippability Nominal cross-sectional area of the conductor Range Insulation stripping capability Range: Nominal cross-sectional area VW 60306-1:2021-10 (p. 9.4.1) VW 60306-2:2021-11 (p. 9.4.1) VW 60306-4:2021-12 (p. 9.4.1) VW 75210-1:2024-08 (p. 9.4.1)","parameters_zh":[{"name":"Nominalne pole przekroju przewodnika"},{"name":"范围","range":"(0,09 - 6,0) mm2"},{"name":"Insulation stripping capability Range: Nominal cross-sectional area","range":"(0,09 - 6,0) mm2"}],"search_zh":"电缆 范围 VW 60306-1:2021-10 (p. 9.4.1) VW 60306-2:2021-11 (p. 9.4.1) VW 60306-4:2021-12 (p. 9.4.1) VW 75210-1:2024-08 (p. 9.4.1)","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a0f9","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Badania wizualne:","methodology_en":"Visual examinations:","parameters":[{"name":"oznakowanie kabla"},{"name":"kolor izolacji / powłoki"}],"parameters_en":[{"name":"cable marking"},{"name":"colour of insulation / sheath"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania wizualne:\nZakres:\noznakowanie kabla\nkolor izolacji / powłoki","reference":"VW 60306-1:2021-10 (p. 7.2) VW 60306-1:2021-10 (p. 7.3) VW 60306-1:2021-10 (p. 7.4.1) VW 60306-2:2021-11 (p. 7.2) VW 60306-2:2021-11 (p. 7.3) VW 60306-2:2021-11 (p. 7.4.1) VW 60306-4:2021-12 (p. 7.2) VW 60306-4:2021-12 (p. 7.3) VW 60306-4:2021-12 (p. 7.4.1) VW 75210-1:2024-08 (p.7.2) VW 75210-1:2024-08 (p.7.3) VW 75210-1:2024-08 (p.7.4.1) VW 75210-2:2019-12 (p. 7.2) VW 75210-2:2019-12 (p. 7.3) VW 75210-2:2019-12 (p. 7.4.1) DIN/TS 70112-1:2024-03 (p. 6.4.3) DIN/TS 70112-1:2024-03 (p. 7.2)","norm_bases":["VW 60306-1:2021-10 (p. 7.2) VW 60306-1:2021-10 (p. 7.3) VW 60306-1:2021-10 (p. 7.4.1) VW 60306-2:2021-11 (p. 7.2) VW 60306-2:2021-11 (p. 7.3) VW 60306-2:2021-11 (p. 7.4.1) VW 60306-4:2021-12 (p. 7.2) VW 60306-4:2021-12 (p. 7.3) VW 60306-4:2021-12 (p. 7.4.1) VW 75210-1:2024-08 (p.7.2) VW 75210-1:2024-08 (p.7.3) VW 75210-1:2024-08 (p.7.4.1) VW 75210-2:2019-12 (p. 7.2) VW 75210-2:2019-12 (p. 7.3) VW 75210-2:2019-12 (p. 7.4.1) DIN/TS 70112-1:2024-03 (p. 6.4.3) DIN/TS 70112-1:2024-03 (p. 7.2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Badania wizualne:\nZakres:\noznakowanie kabla\nkolor izolacji / powłoki VW 60306-1:2021-10 (p. 7.2) VW 60306-1:2021-10 (p. 7.3) VW 60306-1:2021-10 (p. 7.4.1) VW 60306-2:2021-11 (p. 7.2) VW 60306-2:2021-11 (p. 7.3) VW 60306-2:2021-11 (p. 7.4.1) VW 60306-4:2021-12 (p. 7.2) VW 60306-4:2021-12 (p. 7.3) VW 60306-4:2021-12 (p. 7.4.1) VW 75210-1:2024-08 (p.7.2) VW 75210-1:2024-08 (p.7.3) VW 75210-1:2024-08 (p.7.4.1) VW 75210-2:2019-12 (p. 7.2) VW 75210-2:2019-12 (p. 7.3) VW 75210-2:2019-12 (p. 7.4.1) DIN/TS 70112-1:2024-03 (p. 6.4.3) DIN/TS 70112-1:2024-03 (p. 7.2) Kable, Cables Badania wizualne:\nZakres:\noznakowanie kabla\nkolor izolacji / powloki VW 60306-1:2021-10 (p. 7.2) VW 60306-1:2021-10 (p. 7.3) VW 60306-1:2021-10 (p. 7.4.1) VW 60306-2:2021-11 (p. 7.2) VW 60306-2:2021-11 (p. 7.3) VW 60306-2:2021-11 (p. 7.4.1) VW 60306-4:2021-12 (p. 7.2) VW 60306-4:2021-12 (p. 7.3) VW 60306-4:2021-12 (p. 7.4.1) VW 75210-1:2024-08 (p.7.2) VW 75210-1:2024-08 (p.7.3) VW 75210-1:2024-08 (p.7.4.1) VW 75210-2:2019-12 (p. 7.2) VW 75210-2:2019-12 (p. 7.3) VW 75210-2:2019-12 (p. 7.4.1) DIN/TS 70112-1:2024-03 (p. 6.4.3) DIN/TS 70112-1:2024-03 (p. 7.2)","categories":["construction"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Visual examinations: cable marking colour of insulation / sheath VW 60306-1:2021-10 (p. 7.2) VW 60306-1:2021-10 (p. 7.3) VW 60306-1:2021-10 (p. 7.4.1) VW 60306-2:2021-11 (p. 7.2) VW 60306-2:2021-11 (p. 7.3) VW 60306-2:2021-11 (p. 7.4.1) VW 60306-4:2021-12 (p. 7.2) VW 60306-4:2021-12 (p. 7.3) VW 60306-4:2021-12 (p. 7.4.1) VW 75210-1:2024-08 (p.7.2) VW 75210-1:2024-08 (p.7.3) VW 75210-1:2024-08 (p.7.4.1) VW 75210-2:2019-12 (p. 7.2) VW 75210-2:2019-12 (p. 7.3) VW 75210-2:2019-12 (p. 7.4.1) DIN/TS 70112-1:2024-03 (p. 6.4.3) DIN/TS 70112-1:2024-03 (p. 7.2)","search_zh":"电缆 VW 60306-1:2021-10 (p. 7.2) VW 60306-1:2021-10 (p. 7.3) VW 60306-1:2021-10 (p. 7.4.1) VW 60306-2:2021-11 (p. 7.2) VW 60306-2:2021-11 (p. 7.3) VW 60306-2:2021-11 (p. 7.4.1) VW 60306-4:2021-12 (p. 7.2) VW 60306-4:2021-12 (p. 7.3) VW 60306-4:2021-12 (p. 7.4.1) VW 75210-1:2024-08 (p.7.2) VW 75210-1:2024-08 (p.7.3) VW 75210-1:2024-08 (p.7.4.1) VW 75210-2:2019-12 (p. 7.2) VW 75210-2:2019-12 (p. 7.3) VW 75210-2:2019-12 (p. 7.4.1) DIN/TS 70112-1:2024-03 (p. 6.4.3) DIN/TS 70112-1:2024-03 (p. 7.2)","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a0fa","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Stabilność termiczna PVC","methodology_en":"Thermal stability of PVC","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stabilność termiczna PVC","reference":"IEC 60811-405:2012-03 VW 60306-1:2021-10 (p. 9.3.3) VW 60306-2:2021-11 (p. 9.3.3) VW 60306-4:2021-12 (p. 9.3.3) VW 75210-1:2024-08 (p. 9.3.3) VW 75210-2:2019-12 (p. 9.2.2) DIN/TS 70112-1:2024-03 (p. 7.5.3)","norm_bases":["IEC 60811-405:2012-03 VW 60306-1:2021-10 (p. 9.3.3) VW 60306-2:2021-11 (p. 9.3.3) VW 60306-4:2021-12 (p. 9.3.3) VW 75210-1:2024-08 (p. 9.3.3) VW 75210-2:2019-12 (p. 9.2.2) DIN/TS 70112-1:2024-03 (p. 7.5.3)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Stabilność termiczna PVC IEC 60811-405:2012-03 VW 60306-1:2021-10 (p. 9.3.3) VW 60306-2:2021-11 (p. 9.3.3) VW 60306-4:2021-12 (p. 9.3.3) VW 75210-1:2024-08 (p. 9.3.3) VW 75210-2:2019-12 (p. 9.2.2) DIN/TS 70112-1:2024-03 (p. 7.5.3) Kable, Cables Stabilnosc termiczna PVC IEC 60811-405:2012-03 VW 60306-1:2021-10 (p. 9.3.3) VW 60306-2:2021-11 (p. 9.3.3) VW 60306-4:2021-12 (p. 9.3.3) VW 75210-1:2024-08 (p. 9.3.3) VW 75210-2:2019-12 (p. 9.2.2) DIN/TS 70112-1:2024-03 (p. 7.5.3)","categories":["other"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Thermal stability of PVC IEC 60811-405:2012-03 VW 60306-1:2021-10 (p. 9.3.3) VW 60306-2:2021-11 (p. 9.3.3) VW 60306-4:2021-12 (p. 9.3.3) VW 75210-1:2024-08 (p. 9.3.3) VW 75210-2:2019-12 (p. 9.2.2) DIN/TS 70112-1:2024-03 (p. 7.5.3)","search_zh":"电缆 IEC 60811-405:2012-03 VW 60306-1:2021-10 (p. 9.3.3) VW 60306-2:2021-11 (p. 9.3.3) VW 60306-4:2021-12 (p. 9.3.3) VW 75210-1:2024-08 (p. 9.3.3) VW 75210-2:2019-12 (p. 9.2.2) DIN/TS 70112-1:2024-03 (p. 7.5.3)","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a0fb","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Sprawdzenie wydłużenia trwałego w podwyższonej temperaturze tworzyw usieciowanych (Hot set test)","methodology_en":"Verification of permanent elongation at elevated temperature of cross-linked materials (Hot set test)","parameters":[{"name":"Piec","range":"do 250 °C (± 4 °C)"}],"parameters_en":[{"name":"Stove","range":"do 250 °C (± 4 °C)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawdzenie wydłużenia trwałego w podwyższonej temperaturze tworzyw usieciowanych (Hot set test)\nPiec do 250 °C (± 4 °C)","reference":"IEC 60811-507:2012-03 VW 60306-1:2021-10 ( p. 9.3.6) VW 60306-2:2021-11 ( p. 9.3.6) VW 60306-4:2021-12 ( p. 9.3.6) VW 75210-1:2024-08 (p. 9.3.7) VW 75210-2:2019-12 (p. 9.2.6) DIN/TS 70112-1:2024-03 (p. 7.5.8) Scope of accreditation No. AB 1814","norm_bases":["IEC 60811-507:2012-03 VW 60306-1:2021-10 ( p. 9.3.6) VW 60306-2:2021-11 ( p. 9.3.6) VW 60306-4:2021-12 ( p. 9.3.6) VW 75210-1:2024-08 (p. 9.3.7) VW 75210-2:2019-12 (p. 9.2.6) DIN/TS 70112-1:2024-03 (p. 7.5.8) Scope of accreditation No. AB 1814"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Sprawdzenie wydłużenia trwałego w podwyższonej temperaturze tworzyw usieciowanych (Hot set test)\nPiec do 250 °C (± 4 °C) IEC 60811-507:2012-03 VW 60306-1:2021-10 ( p. 9.3.6) VW 60306-2:2021-11 ( p. 9.3.6) VW 60306-4:2021-12 ( p. 9.3.6) VW 75210-1:2024-08 (p. 9.3.7) VW 75210-2:2019-12 (p. 9.2.6) DIN/TS 70112-1:2024-03 (p. 7.5.8) Scope of accreditation No. AB 1814 Kable, Cables Sprawdzenie wydluzenia trwalego w podwyzszonej temperaturze tworzyw usieciowanych (Hot set test)\nPiec do 250 °C (± 4 °C) IEC 60811-507:2012-03 VW 60306-1:2021-10 ( p. 9.3.6) VW 60306-2:2021-11 ( p. 9.3.6) VW 60306-4:2021-12 ( p. 9.3.6) VW 75210-1:2024-08 (p. 9.3.7) VW 75210-2:2019-12 (p. 9.2.6) DIN/TS 70112-1:2024-03 (p. 7.5.8) Scope of accreditation No. AB 1814","categories":["other"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Verification of permanent elongation at elevated temperature of cross-linked materials (Hot set test) Stove IEC 60811-507:2012-03 VW 60306-1:2021-10 ( p. 9.3.6) VW 60306-2:2021-11 ( p. 9.3.6) VW 60306-4:2021-12 ( p. 9.3.6) VW 75210-1:2024-08 (p. 9.3.7) VW 75210-2:2019-12 (p. 9.2.6) DIN/TS 70112-1:2024-03 (p. 7.5.8) Scope of accreditation No. AB 1814","search_zh":"电缆 炉窑 IEC 60811-507:2012-03 VW 60306-1:2021-10 ( p. 9.3.6) VW 60306-2:2021-11 ( p. 9.3.6) VW 60306-4:2021-12 ( p. 9.3.6) VW 75210-1:2024-08 (p. 9.3.7) VW 75210-2:2019-12 (p. 9.2.6) DIN/TS 70112-1:2024-03 (p. 7.5.8) Scope of accreditation No. AB 1814","test_object_zh":"电缆","parameters_zh":[{"name":"炉窑","range":"do 250 °C (± 4 °C)"}]},{"_id":"6a5dc9aaf1c10c8ce825a0fc","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Trwałość oznakowania powłoki /izolacji/ płaszcza","methodology_en":"Durability of marking of the coating /insulation/ sheath","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość oznakowania powłoki /izolacji/ płaszcza","reference":"ISO 19642-2:2023-08 (p. 5.5.12) | ISO 19642-2:2023-08 (p. 6.5.11) | ISO 19642-3:2019-01 (p. 5.5.12) | ISO 19642-4:2019-01 (p. 5.5.12) | ISO 19642-5:2019-01 (p. 5.5.12) | ISO 19642-6:2019-01 (p. 5.5.12) | ISO 19642-7:2019-01 (p. 6.5.11) | ISO 19642-8:2019-01 (p. 6.5.11) | ISO 19642-9:2019-01 (p. 6.5.11) | ISO 19642-10:2019-01 (p. 6.5.11) VW 60306-1:2021-10 (p. 9.7.11) VW 60306-2:2021-11 (p. 9.7.11) VW 60306-4:2021-12 (p. 9.7.11) VW 75209-1:2021-12 (p. 9.7.9) VW 75209-2:2021-12 (p. 9.7.10) VW 75210-1:2024-08 (p. 9.7.11) VW 75210-2:2019-12 (p. 9.6.10) | ISO 6722-1:2011; corr.1:2012 (p. 5.18) | ISO 6722-2:2013 (p. 5.18) DIN/TS 70112-1:2024-03 (p. 7.8.12)","norm_bases":["ISO 19642-2:2023-08 (p. 5.5.12)","ISO 19642-2:2023-08 (p. 6.5.11)","ISO 19642-3:2019-01 (p. 5.5.12)","ISO 19642-4:2019-01 (p. 5.5.12)","ISO 19642-5:2019-01 (p. 5.5.12)","ISO 19642-6:2019-01 (p. 5.5.12)","ISO 19642-7:2019-01 (p. 6.5.11)","ISO 19642-8:2019-01 (p. 6.5.11)","ISO 19642-9:2019-01 (p. 6.5.11)","ISO 19642-10:2019-01 (p. 6.5.11) VW 60306-1:2021-10 (p. 9.7.11) VW 60306-2:2021-11 (p. 9.7.11) VW 60306-4:2021-12 (p. 9.7.11) VW 75209-1:2021-12 (p. 9.7.9) VW 75209-2:2021-12 (p. 9.7.10) VW 75210-1:2024-08 (p. 9.7.11) VW 75210-2:2019-12 (p. 9.6.10)","ISO 6722-1:2011; corr.1:2012 (p. 5.18)","ISO 6722-2:2013 (p. 5.18) DIN/TS 70112-1:2024-03 (p. 7.8.12)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Trwałość oznakowania powłoki /izolacji/ płaszcza ISO 19642-2:2023-08 (p. 5.5.12) | ISO 19642-2:2023-08 (p. 6.5.11) | ISO 19642-3:2019-01 (p. 5.5.12) | ISO 19642-4:2019-01 (p. 5.5.12) | ISO 19642-5:2019-01 (p. 5.5.12) | ISO 19642-6:2019-01 (p. 5.5.12) | ISO 19642-7:2019-01 (p. 6.5.11) | ISO 19642-8:2019-01 (p. 6.5.11) | ISO 19642-9:2019-01 (p. 6.5.11) | ISO 19642-10:2019-01 (p. 6.5.11) VW 60306-1:2021-10 (p. 9.7.11) VW 60306-2:2021-11 (p. 9.7.11) VW 60306-4:2021-12 (p. 9.7.11) VW 75209-1:2021-12 (p. 9.7.9) VW 75209-2:2021-12 (p. 9.7.10) VW 75210-1:2024-08 (p. 9.7.11) VW 75210-2:2019-12 (p. 9.6.10) | ISO 6722-1:2011; corr.1:2012 (p. 5.18) | ISO 6722-2:2013 (p. 5.18) DIN/TS 70112-1:2024-03 (p. 7.8.12) Kable, Cables Trwalosc oznakowania powloki /izolacji/ plaszcza ISO 19642-2:2023-08 (p. 5.5.12) | ISO 19642-2:2023-08 (p. 6.5.11) | ISO 19642-3:2019-01 (p. 5.5.12) | ISO 19642-4:2019-01 (p. 5.5.12) | ISO 19642-5:2019-01 (p. 5.5.12) | ISO 19642-6:2019-01 (p. 5.5.12) | ISO 19642-7:2019-01 (p. 6.5.11) | ISO 19642-8:2019-01 (p. 6.5.11) | ISO 19642-9:2019-01 (p. 6.5.11) | ISO 19642-10:2019-01 (p. 6.5.11) VW 60306-1:2021-10 (p. 9.7.11) VW 60306-2:2021-11 (p. 9.7.11) VW 60306-4:2021-12 (p. 9.7.11) VW 75209-1:2021-12 (p. 9.7.9) VW 75209-2:2021-12 (p. 9.7.10) VW 75210-1:2024-08 (p. 9.7.11) VW 75210-2:2019-12 (p. 9.6.10) | ISO 6722-1:2011; corr.1:2012 (p. 5.18) | ISO 6722-2:2013 (p. 5.18) DIN/TS 70112-1:2024-03 (p. 7.8.12)","categories":["construction"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Durability of marking of the coating /insulation/ sheath ISO 19642-2:2023-08 (p. 5.5.12) | ISO 19642-2:2023-08 (p. 6.5.11) | ISO 19642-3:2019-01 (p. 5.5.12) | ISO 19642-4:2019-01 (p. 5.5.12) | ISO 19642-5:2019-01 (p. 5.5.12) | ISO 19642-6:2019-01 (p. 5.5.12) | ISO 19642-7:2019-01 (p. 6.5.11) | ISO 19642-8:2019-01 (p. 6.5.11) | ISO 19642-9:2019-01 (p. 6.5.11) | ISO 19642-10:2019-01 (p. 6.5.11) VW 60306-1:2021-10 (p. 9.7.11) VW 60306-2:2021-11 (p. 9.7.11) VW 60306-4:2021-12 (p. 9.7.11) VW 75209-1:2021-12 (p. 9.7.9) VW 75209-2:2021-12 (p. 9.7.10) VW 75210-1:2024-08 (p. 9.7.11) VW 75210-2:2019-12 (p. 9.6.10) | ISO 6722-1:2011; corr.1:2012 (p. 5.18) | ISO 6722-2:2013 (p. 5.18) DIN/TS 70112-1:2024-03 (p. 7.8.12)","search_zh":"电缆 ISO 19642-2:2023-08 (p. 5.5.12) | ISO 19642-2:2023-08 (p. 6.5.11) | ISO 19642-3:2019-01 (p. 5.5.12) | ISO 19642-4:2019-01 (p. 5.5.12) | ISO 19642-5:2019-01 (p. 5.5.12) | ISO 19642-6:2019-01 (p. 5.5.12) | ISO 19642-7:2019-01 (p. 6.5.11) | ISO 19642-8:2019-01 (p. 6.5.11) | ISO 19642-9:2019-01 (p. 6.5.11) | ISO 19642-10:2019-01 (p. 6.5.11) VW 60306-1:2021-10 (p. 9.7.11) VW 60306-2:2021-11 (p. 9.7.11) VW 60306-4:2021-12 (p. 9.7.11) VW 75209-1:2021-12 (p. 9.7.9) VW 75209-2:2021-12 (p. 9.7.10) VW 75210-1:2024-08 (p. 9.7.11) VW 75210-2:2019-12 (p. 9.6.10) | ISO 6722-1:2011; corr.1:2012 (p. 5.18) | ISO 6722-2:2013 (p. 5.18) DIN/TS 70112-1:2024-03 (p. 7.8.12)","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a0fd","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Odporność kabla na pękanie zmęczeniowe","methodology_en":"Resistance of the cable to fatigue cracking","parameters":[{"name":"Piec","range":"do 250 °C (± 4 °C)"}],"parameters_en":[{"name":"Stove","range":"do 250 °C (± 4 °C)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność kabla na pękanie zmęczeniowe\nPiec do 250 °C (± 4 °C)","reference":"ISO 19642-2:2023-08 (p. 5.5.13) | ISO 19642-3:2019-01 (p. 5.5.13) | ISO 19642-4:2019-01 (p. 5.5.13) | ISO 19642-5:2019-01 (p. 5.5.13) | ISO 19642-6:2019-01 (p. 5.5.13) VW 60306-1:2021-10 (p. 9.7.1) VW 60306-2:2021-11 (p. 9.7.1) VW 60306-4:2021-12 (p. 9.7.1) VW 75210-1:2024-08 (p. 9.7.1) VW 75210-2:2019-12 (p. 9.6.1) DIN/TS 70112-1:2024-03 (p. 7.8.1)","norm_bases":["ISO 19642-2:2023-08 (p. 5.5.13)","ISO 19642-3:2019-01 (p. 5.5.13)","ISO 19642-4:2019-01 (p. 5.5.13)","ISO 19642-5:2019-01 (p. 5.5.13)","ISO 19642-6:2019-01 (p. 5.5.13) VW 60306-1:2021-10 (p. 9.7.1) VW 60306-2:2021-11 (p. 9.7.1) VW 60306-4:2021-12 (p. 9.7.1) VW 75210-1:2024-08 (p. 9.7.1) VW 75210-2:2019-12 (p. 9.6.1) DIN/TS 70112-1:2024-03 (p. 7.8.1)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Odporność kabla na pękanie zmęczeniowe\nPiec do 250 °C (± 4 °C) ISO 19642-2:2023-08 (p. 5.5.13) | ISO 19642-3:2019-01 (p. 5.5.13) | ISO 19642-4:2019-01 (p. 5.5.13) | ISO 19642-5:2019-01 (p. 5.5.13) | ISO 19642-6:2019-01 (p. 5.5.13) VW 60306-1:2021-10 (p. 9.7.1) VW 60306-2:2021-11 (p. 9.7.1) VW 60306-4:2021-12 (p. 9.7.1) VW 75210-1:2024-08 (p. 9.7.1) VW 75210-2:2019-12 (p. 9.6.1) DIN/TS 70112-1:2024-03 (p. 7.8.1) Kable, Cables Odpornosc kabla na pekanie zmeczeniowe\nPiec do 250 °C (± 4 °C) ISO 19642-2:2023-08 (p. 5.5.13) | ISO 19642-3:2019-01 (p. 5.5.13) | ISO 19642-4:2019-01 (p. 5.5.13) | ISO 19642-5:2019-01 (p. 5.5.13) | ISO 19642-6:2019-01 (p. 5.5.13) VW 60306-1:2021-10 (p. 9.7.1) VW 60306-2:2021-11 (p. 9.7.1) VW 60306-4:2021-12 (p. 9.7.1) VW 75210-1:2024-08 (p. 9.7.1) VW 75210-2:2019-12 (p. 9.6.1) DIN/TS 70112-1:2024-03 (p. 7.8.1)","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Resistance of the cable to fatigue cracking Stove ISO 19642-2:2023-08 (p. 5.5.13) | ISO 19642-3:2019-01 (p. 5.5.13) | ISO 19642-4:2019-01 (p. 5.5.13) | ISO 19642-5:2019-01 (p. 5.5.13) | ISO 19642-6:2019-01 (p. 5.5.13) VW 60306-1:2021-10 (p. 9.7.1) VW 60306-2:2021-11 (p. 9.7.1) VW 60306-4:2021-12 (p. 9.7.1) VW 75210-1:2024-08 (p. 9.7.1) VW 75210-2:2019-12 (p. 9.6.1) DIN/TS 70112-1:2024-03 (p. 7.8.1)","search_zh":"电缆 炉窑 ISO 19642-2:2023-08 (p. 5.5.13) | ISO 19642-3:2019-01 (p. 5.5.13) | ISO 19642-4:2019-01 (p. 5.5.13) | ISO 19642-5:2019-01 (p. 5.5.13) | ISO 19642-6:2019-01 (p. 5.5.13) VW 60306-1:2021-10 (p. 9.7.1) VW 60306-2:2021-11 (p. 9.7.1) VW 60306-4:2021-12 (p. 9.7.1) VW 75210-1:2024-08 (p. 9.7.1) VW 75210-2:2019-12 (p. 9.6.1) DIN/TS 70112-1:2024-03 (p. 7.8.1)","test_object_zh":"电缆","parameters_zh":[{"name":"炉窑","range":"do 250 °C (± 4 °C)"}]},{"_id":"6a5dc9aaf1c10c8ce825a0fe","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Test elastyczności kabla","methodology_en":"Cable flexibility test","parameters":[{"name":"Kabel o średnicy zewnętrznej ≤ 28 mm Maszyna wytrzymałościowa:"},{"name":"Zakres","range":"(0,2 – 2500) N"}],"parameters_en":[{"name":"Cable with outer diameter ≤ 28 mm Testing machine:"},{"name":"Range","range":"(0,2 – 2500) N"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Test elastyczności kabla\nZakres:\nKabel o średnicy zewnętrznej ≤ 28 mm Maszyna wytrzymałościowa:\nZakres (0,2 – 2500) N","reference":"ISO 19642-2:2023-08 (p. 5.4.5) | ISO 19642-2:2023-08 (p. 6.4.3) | ISO 19642-3:2019-01 (p. 5.4.5) | ISO 19642-4:2019-01 (p. 5.4.5) | ISO 19642-5:2019-01 (p. 5.4.5) | ISO 19642-6:2019-01 (p. 5.4.5) | ISO 19642-7:2019-01 (p. 6.4.3) | ISO 19642-8:2019-01 (p. 6.4.3) | ISO 19642-9:2019-01 (p. 6.4.3) | ISO 19642-10:2019-01 (p. 6.4.3) DIN/TS 70112-1:2024-03 (p. 7.6.3) Scope of accreditation No. AB 1814","norm_bases":["ISO 19642-2:2023-08 (p. 5.4.5)","ISO 19642-2:2023-08 (p. 6.4.3)","ISO 19642-3:2019-01 (p. 5.4.5)","ISO 19642-4:2019-01 (p. 5.4.5)","ISO 19642-5:2019-01 (p. 5.4.5)","ISO 19642-6:2019-01 (p. 5.4.5)","ISO 19642-7:2019-01 (p. 6.4.3)","ISO 19642-8:2019-01 (p. 6.4.3)","ISO 19642-9:2019-01 (p. 6.4.3)","ISO 19642-10:2019-01 (p. 6.4.3) DIN/TS 70112-1:2024-03 (p. 7.6.3) Scope of accreditation No. AB 1814"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Test elastyczności kabla\nZakres:\nKabel o średnicy zewnętrznej ≤ 28 mm Maszyna wytrzymałościowa:\nZakres (0,2 – 2500) N ISO 19642-2:2023-08 (p. 5.4.5) | ISO 19642-2:2023-08 (p. 6.4.3) | ISO 19642-3:2019-01 (p. 5.4.5) | ISO 19642-4:2019-01 (p. 5.4.5) | ISO 19642-5:2019-01 (p. 5.4.5) | ISO 19642-6:2019-01 (p. 5.4.5) | ISO 19642-7:2019-01 (p. 6.4.3) | ISO 19642-8:2019-01 (p. 6.4.3) | ISO 19642-9:2019-01 (p. 6.4.3) | ISO 19642-10:2019-01 (p. 6.4.3) DIN/TS 70112-1:2024-03 (p. 7.6.3) Scope of accreditation No. AB 1814 Kable, Cables Test elastycznosci kabla\nZakres:\nKabel o srednicy zewnetrznej ≤ 28 mm Maszyna wytrzymalosciowa:\nZakres (0,2 – 2500) N ISO 19642-2:2023-08 (p. 5.4.5) | ISO 19642-2:2023-08 (p. 6.4.3) | ISO 19642-3:2019-01 (p. 5.4.5) | ISO 19642-4:2019-01 (p. 5.4.5) | ISO 19642-5:2019-01 (p. 5.4.5) | ISO 19642-6:2019-01 (p. 5.4.5) | ISO 19642-7:2019-01 (p. 6.4.3) | ISO 19642-8:2019-01 (p. 6.4.3) | ISO 19642-9:2019-01 (p. 6.4.3) | ISO 19642-10:2019-01 (p. 6.4.3) DIN/TS 70112-1:2024-03 (p. 7.6.3) Scope of accreditation No. AB 1814","categories":["other"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Cable flexibility test Cable with outer diameter ≤ 28 mm Testing machine: Range ISO 19642-2:2023-08 (p. 5.4.5) | ISO 19642-2:2023-08 (p. 6.4.3) | ISO 19642-3:2019-01 (p. 5.4.5) | ISO 19642-4:2019-01 (p. 5.4.5) | ISO 19642-5:2019-01 (p. 5.4.5) | ISO 19642-6:2019-01 (p. 5.4.5) | ISO 19642-7:2019-01 (p. 6.4.3) | ISO 19642-8:2019-01 (p. 6.4.3) | ISO 19642-9:2019-01 (p. 6.4.3) | ISO 19642-10:2019-01 (p. 6.4.3) DIN/TS 70112-1:2024-03 (p. 7.6.3) Scope of accreditation No. AB 1814","parameters_zh":[{"name":"Kabel o średnicy zewnętrznej ≤ 28 mm Maszyna wytrzymałościowa:"},{"name":"范围","range":"(0,2 – 2500) N"}],"search_zh":"电缆 范围 ISO 19642-2:2023-08 (p. 5.4.5) | ISO 19642-2:2023-08 (p. 6.4.3) | ISO 19642-3:2019-01 (p. 5.4.5) | ISO 19642-4:2019-01 (p. 5.4.5) | ISO 19642-5:2019-01 (p. 5.4.5) | ISO 19642-6:2019-01 (p. 5.4.5) | ISO 19642-7:2019-01 (p. 6.4.3) | ISO 19642-8:2019-01 (p. 6.4.3) | ISO 19642-9:2019-01 (p. 6.4.3) | ISO 19642-10:2019-01 (p. 6.4.3) DIN/TS 70112-1:2024-03 (p. 7.6.3) Scope of accreditation No. AB 1814","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a0ff","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Skurcz izolacji / powłoki kabla pod wpływem ciepła","methodology_en":"Heat shrinkage of the cable insulation / sheath","parameters":[{"name":"Zakres","range":"(0,01-25) mm"},{"name":"Piec","range":"do 250°C (± 4°C)"}],"parameters_en":[{"name":"Range","range":"(0,01-25) mm"},{"name":"Stove","range":"do 250°C (± 4°C)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Skurcz izolacji / powłoki kabla pod wpływem ciepła\nZakres:\nZakres (0,01-25) mm\nPiec do 250°C (± 4°C)","reference":"ISO 19642-2:2023-08 (p. 5.5.6) | ISO 19642-2:2023-08 (p. 6.5.6) | ISO 19642-3:2019-01 (p. 5.5.6) | ISO 19642-4:2019-01 (p. 5.5.6) | ISO 19642-5:2019-01 (p. 5.5.6) | ISO 19642-6:2019-01 (p. 5.5.6) | ISO 19642-7:2019-01 (p. 6.5.6) | ISO 19642-8:2019-01 (p. 6.5.6) | ISO 19642-9:2019-01 (p. 6.5.6) | ISO 19642-10:2019-01 (p. 6.5.6) VW 60306-1:2021-10 (p. 9.7.2) VW 60306-2:2021-11 (p. 9.7.2) VW 60306-4:2021-12 (p. 9.7.2) VW 75210-1:2024-08 (p. 9.7.2) VW 75210-2:2019-12 (p. 9.6.2) DIN/TS 70112-1:2024-03 (p. 7.8.2)","norm_bases":["ISO 19642-2:2023-08 (p. 5.5.6)","ISO 19642-2:2023-08 (p. 6.5.6)","ISO 19642-3:2019-01 (p. 5.5.6)","ISO 19642-4:2019-01 (p. 5.5.6)","ISO 19642-5:2019-01 (p. 5.5.6)","ISO 19642-6:2019-01 (p. 5.5.6)","ISO 19642-7:2019-01 (p. 6.5.6)","ISO 19642-8:2019-01 (p. 6.5.6)","ISO 19642-9:2019-01 (p. 6.5.6)","ISO 19642-10:2019-01 (p. 6.5.6) VW 60306-1:2021-10 (p. 9.7.2) VW 60306-2:2021-11 (p. 9.7.2) VW 60306-4:2021-12 (p. 9.7.2) VW 75210-1:2024-08 (p. 9.7.2) VW 75210-2:2019-12 (p. 9.6.2) DIN/TS 70112-1:2024-03 (p. 7.8.2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Skurcz izolacji / powłoki kabla pod wpływem ciepła\nZakres:\nZakres (0,01-25) mm\nPiec do 250°C (± 4°C) ISO 19642-2:2023-08 (p. 5.5.6) | ISO 19642-2:2023-08 (p. 6.5.6) | ISO 19642-3:2019-01 (p. 5.5.6) | ISO 19642-4:2019-01 (p. 5.5.6) | ISO 19642-5:2019-01 (p. 5.5.6) | ISO 19642-6:2019-01 (p. 5.5.6) | ISO 19642-7:2019-01 (p. 6.5.6) | ISO 19642-8:2019-01 (p. 6.5.6) | ISO 19642-9:2019-01 (p. 6.5.6) | ISO 19642-10:2019-01 (p. 6.5.6) VW 60306-1:2021-10 (p. 9.7.2) VW 60306-2:2021-11 (p. 9.7.2) VW 60306-4:2021-12 (p. 9.7.2) VW 75210-1:2024-08 (p. 9.7.2) VW 75210-2:2019-12 (p. 9.6.2) DIN/TS 70112-1:2024-03 (p. 7.8.2) Kable, Cables Skurcz izolacji / powloki kabla pod wplywem ciepla\nZakres:\nZakres (0,01-25) mm\nPiec do 250°C (± 4°C) ISO 19642-2:2023-08 (p. 5.5.6) | ISO 19642-2:2023-08 (p. 6.5.6) | ISO 19642-3:2019-01 (p. 5.5.6) | ISO 19642-4:2019-01 (p. 5.5.6) | ISO 19642-5:2019-01 (p. 5.5.6) | ISO 19642-6:2019-01 (p. 5.5.6) | ISO 19642-7:2019-01 (p. 6.5.6) | ISO 19642-8:2019-01 (p. 6.5.6) | ISO 19642-9:2019-01 (p. 6.5.6) | ISO 19642-10:2019-01 (p. 6.5.6) VW 60306-1:2021-10 (p. 9.7.2) VW 60306-2:2021-11 (p. 9.7.2) VW 60306-4:2021-12 (p. 9.7.2) VW 75210-1:2024-08 (p. 9.7.2) VW 75210-2:2019-12 (p. 9.6.2) DIN/TS 70112-1:2024-03 (p. 7.8.2)","categories":["construction"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Heat shrinkage of the cable insulation / sheath Range Stove ISO 19642-2:2023-08 (p. 5.5.6) | ISO 19642-2:2023-08 (p. 6.5.6) | ISO 19642-3:2019-01 (p. 5.5.6) | ISO 19642-4:2019-01 (p. 5.5.6) | ISO 19642-5:2019-01 (p. 5.5.6) | ISO 19642-6:2019-01 (p. 5.5.6) | ISO 19642-7:2019-01 (p. 6.5.6) | ISO 19642-8:2019-01 (p. 6.5.6) | ISO 19642-9:2019-01 (p. 6.5.6) | ISO 19642-10:2019-01 (p. 6.5.6) VW 60306-1:2021-10 (p. 9.7.2) VW 60306-2:2021-11 (p. 9.7.2) VW 60306-4:2021-12 (p. 9.7.2) VW 75210-1:2024-08 (p. 9.7.2) VW 75210-2:2019-12 (p. 9.6.2) DIN/TS 70112-1:2024-03 (p. 7.8.2)","parameters_zh":[{"name":"范围","range":"(0,01-25) mm"},{"name":"炉窑","range":"do 250°C (± 4°C)"}],"search_zh":"电缆 范围 炉窑 ISO 19642-2:2023-08 (p. 5.5.6) | ISO 19642-2:2023-08 (p. 6.5.6) | ISO 19642-3:2019-01 (p. 5.5.6) | ISO 19642-4:2019-01 (p. 5.5.6) | ISO 19642-5:2019-01 (p. 5.5.6) | ISO 19642-6:2019-01 (p. 5.5.6) | ISO 19642-7:2019-01 (p. 6.5.6) | ISO 19642-8:2019-01 (p. 6.5.6) | ISO 19642-9:2019-01 (p. 6.5.6) | ISO 19642-10:2019-01 (p. 6.5.6) VW 60306-1:2021-10 (p. 9.7.2) VW 60306-2:2021-11 (p. 9.7.2) VW 60306-4:2021-12 (p. 9.7.2) VW 75210-1:2024-08 (p. 9.7.2) VW 75210-2:2019-12 (p. 9.6.2) DIN/TS 70112-1:2024-03 (p. 7.8.2)","test_object_zh":"电缆"},{"_id":"6a5dc9aaf1c10c8ce825a100","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Odporność na chemikalia i kwas akumulatorowy","methodology_en":"Resistance to chemicals and battery acid","parameters":[{"name":"Piec","range":"do 250°C (± 4 °C)"}],"parameters_en":[{"name":"Stove","range":"do 250°C (± 4 °C)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na chemikalia i kwas akumulatorowy\nPiec do 250°C (± 4 °C)","reference":"ISO 19642-2:2023-08 (p. 5.5.11) | ISO 19642-2:2023-08 (p. 6.5.10) | ISO 19642-3:2019-01 (p. 5.5.11) | ISO 19642-4:2019-01 (p. 5.5.11) | ISO 19642-5:2019-01 (p. 5.5.11) | ISO 19642-6:2019-01 (p. 5.5.11) | ISO 19642-7:2019-01 (p. 6.5.10) | ISO 19642-8:2019-01 (p. 6.5.10) | ISO 19642-9:2019-01 (p. 6.5.10) | ISO 19642-10:2019-01 (p. 6.5.10) VW 60306-1:2021-10 (p. 9.9) VW 60306-2:2021-11 (p. 9.9) VW 60306-4:2021-12 (p. 9.9) DIN/TS 70112-1:2024-03 (p. 7.9.1)","norm_bases":["ISO 19642-2:2023-08 (p. 5.5.11)","ISO 19642-2:2023-08 (p. 6.5.10)","ISO 19642-3:2019-01 (p. 5.5.11)","ISO 19642-4:2019-01 (p. 5.5.11)","ISO 19642-5:2019-01 (p. 5.5.11)","ISO 19642-6:2019-01 (p. 5.5.11)","ISO 19642-7:2019-01 (p. 6.5.10)","ISO 19642-8:2019-01 (p. 6.5.10)","ISO 19642-9:2019-01 (p. 6.5.10)","ISO 19642-10:2019-01 (p. 6.5.10) VW 60306-1:2021-10 (p. 9.9) VW 60306-2:2021-11 (p. 9.9) VW 60306-4:2021-12 (p. 9.9) DIN/TS 70112-1:2024-03 (p. 7.9.1)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Odporność na chemikalia i kwas akumulatorowy\nPiec do 250°C (± 4 °C) ISO 19642-2:2023-08 (p. 5.5.11) | ISO 19642-2:2023-08 (p. 6.5.10) | ISO 19642-3:2019-01 (p. 5.5.11) | ISO 19642-4:2019-01 (p. 5.5.11) | ISO 19642-5:2019-01 (p. 5.5.11) | ISO 19642-6:2019-01 (p. 5.5.11) | ISO 19642-7:2019-01 (p. 6.5.10) | ISO 19642-8:2019-01 (p. 6.5.10) | ISO 19642-9:2019-01 (p. 6.5.10) | ISO 19642-10:2019-01 (p. 6.5.10) VW 60306-1:2021-10 (p. 9.9) VW 60306-2:2021-11 (p. 9.9) VW 60306-4:2021-12 (p. 9.9) DIN/TS 70112-1:2024-03 (p. 7.9.1) Kable, Cables Odpornosc na chemikalia i kwas akumulatorowy\nPiec do 250°C (± 4 °C) ISO 19642-2:2023-08 (p. 5.5.11) | ISO 19642-2:2023-08 (p. 6.5.10) | ISO 19642-3:2019-01 (p. 5.5.11) | ISO 19642-4:2019-01 (p. 5.5.11) | ISO 19642-5:2019-01 (p. 5.5.11) | ISO 19642-6:2019-01 (p. 5.5.11) | ISO 19642-7:2019-01 (p. 6.5.10) | ISO 19642-8:2019-01 (p. 6.5.10) | ISO 19642-9:2019-01 (p. 6.5.10) | ISO 19642-10:2019-01 (p. 6.5.10) VW 60306-1:2021-10 (p. 9.9) VW 60306-2:2021-11 (p. 9.9) VW 60306-4:2021-12 (p. 9.9) DIN/TS 70112-1:2024-03 (p. 7.9.1)","categories":["other"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Resistance to chemicals and battery acid Stove ISO 19642-2:2023-08 (p. 5.5.11) | ISO 19642-2:2023-08 (p. 6.5.10) | ISO 19642-3:2019-01 (p. 5.5.11) | ISO 19642-4:2019-01 (p. 5.5.11) | ISO 19642-5:2019-01 (p. 5.5.11) | ISO 19642-6:2019-01 (p. 5.5.11) | ISO 19642-7:2019-01 (p. 6.5.10) | ISO 19642-8:2019-01 (p. 6.5.10) | ISO 19642-9:2019-01 (p. 6.5.10) | ISO 19642-10:2019-01 (p. 6.5.10) VW 60306-1:2021-10 (p. 9.9) VW 60306-2:2021-11 (p. 9.9) VW 60306-4:2021-12 (p. 9.9) DIN/TS 70112-1:2024-03 (p. 7.9.1)","search_zh":"电缆 炉窑 ISO 19642-2:2023-08 (p. 5.5.11) | ISO 19642-2:2023-08 (p. 6.5.10) | ISO 19642-3:2019-01 (p. 5.5.11) | ISO 19642-4:2019-01 (p. 5.5.11) | ISO 19642-5:2019-01 (p. 5.5.11) | ISO 19642-6:2019-01 (p. 5.5.11) | ISO 19642-7:2019-01 (p. 6.5.10) | ISO 19642-8:2019-01 (p. 6.5.10) | ISO 19642-9:2019-01 (p. 6.5.10) | ISO 19642-10:2019-01 (p. 6.5.10) VW 60306-1:2021-10 (p. 9.9) VW 60306-2:2021-11 (p. 9.9) VW 60306-4:2021-12 (p. 9.9) DIN/TS 70112-1:2024-03 (p. 7.9.1)","test_object_zh":"电缆","parameters_zh":[{"name":"炉窑","range":"do 250°C (± 4 °C)"}]},{"_id":"6a5dc9aaf1c10c8ce825a101","lab_id":"69ad52a3de79e566650fb9b3","country":"PL","accr_number":"AB 1814","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Średnica pojedynczego drutu","methodology_en":"Diameter of a single wire","parameters":[{"name":"Zakres","range":"(0,0500 – 0,8000) mm"}],"parameters_en":[{"name":"Range","range":"(0,0500 – 0,8000) mm"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Średnica pojedynczego drutu\nZakres (0,0500 – 0,8000) mm","reference":"ASTM B3-13 (p. 6.3); | ASTM B33-00 (p. 6.3) Scope of accreditation No. AB 1814","norm_bases":["ASTM B3-13 (p. 6.3);","ASTM B33-00 (p. 6.3) Scope of accreditation No. AB 1814"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Średnica pojedynczego drutu\nZakres (0,0500 – 0,8000) mm ASTM B3-13 (p. 6.3); | ASTM B33-00 (p. 6.3) Scope of accreditation No. AB 1814 Kable, Cables Srednica pojedynczego drutu\nZakres (0,0500 – 0,8000) mm ASTM B3-13 (p. 6.3); | ASTM B33-00 (p. 6.3) Scope of accreditation No. AB 1814","categories":["other"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Diameter of a single wire Range ASTM B3-13 (p. 6.3); | ASTM B33-00 (p. 6.3) Scope of accreditation No. AB 1814","parameters_zh":[{"name":"范围","range":"(0,0500 – 0,8000) mm"}],"search_zh":"电缆 范围 ASTM B3-13 (p. 6.3); | ASTM B33-00 (p. 6.3) Scope of accreditation No. AB 1814","test_object_zh":"电缆"}],"has_pdf":true}