{"lab":{"_id":"69ad52a3de79e566650fb9a1","accr_number":"AB 1803","country":"PL","accr_body":"PCA","address":"w Nowym Sączu, LABORATORIUM BADAWCZE MPEC NOWY SĄCZ, ul. J. Wiśniowieckiego 56","categories":["petro"],"city":"Nowy Sącz","imported_at":"2026-03-08T10:42:43.265Z","methods_count":8,"name":"MIEJSKIE PRZEDSIĘBIORSTWO ENERGETYKI CIEPLNEJ Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1803.pdf"],"scope_summary":"","search_text":"miejskie przedsiębiorstwo energetyki cieplnej sp. z o.o. w nowym sączu, laboratorium badawcze mpec nowy sącz, ul. j. wiśniowieckiego 56 petro other","status":"active","updated_at":"2026-03-08T14:50:56.372Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:56.372Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201803,podmiot.html","fields_of_testing":[{"codes":"N/10","pl":"Badania właściwości fizycznych paliw stałych","en":"Tests of physical properties of solid fuels"},{"codes":"C/10","pl":"Badania chemiczne paliw stałych","en":"Chemical tests of solid fuels"}],"issue":{"no":"3","date":"15.09.2025"},"parse_date":"2026-07-20T07:09:29.874Z","parse_source":"script-pdfplumber","map_coord":[49.624917,20.691346],"map_geo":"nominatim-city","has_en":true,"category_counts":{"petro":8},"category_scores":{"petro":8},"has_zh":true},"methods":[{"_id":"6a5dc9a9f1c10c8ce825a068","lab_id":"69ad52a3de79e566650fb9a1","country":"PL","accr_number":"AB 1803","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(3,0 – 25,0) %"}],"parameters_en":[{"name":"Range","range":"(3,0 – 25,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (3,0 – 25,0) %\nMetoda wagowa","reference":"PB-01 wersja 02 z dnia 20.08.2021 r.","norm_bases":["PB-01 wersja 02 z dnia 20.08.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej\nZakres (3,0 – 25,0) %\nMetoda wagowa PB-01 wersja 02 z dnia 20.08.2021 r. Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej\nZakres (3,0 – 25,0) %\nMetoda wagowa PB-01 wersja 02 z dnia 20.08.2021 r.","categories":["petro"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Total moisture content Gravimetric method Range PB-01 wersja 02 z dnia 20.08.2021 r.","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(3,0 – 25,0) %"}],"search_zh":"固体燃料：烟煤 全水分含量 重量法 范围 PB-01 wersja 02 z dnia 20.08.2021 r.","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9a9f1c10c8ce825a069","lab_id":"69ad52a3de79e566650fb9a1","country":"PL","accr_number":"AB 1803","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci w próbce analitycznej","methodology_en":"Moisture content in the analytical sample","parameters":[{"name":"Zakres","range":"(1,0 – 7,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 7,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 7,0) %\nMetoda wagowa","reference":"PB-01 wersja 02 z dnia 20.08.2021 r.","norm_bases":["PB-01 wersja 02 z dnia 20.08.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 7,0) %\nMetoda wagowa PB-01 wersja 02 z dnia 20.08.2021 r. Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (1,0 – 7,0) %\nMetoda wagowa PB-01 wersja 02 z dnia 20.08.2021 r.","categories":["petro"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Moisture content in the analytical sample Gravimetric method Range PB-01 wersja 02 z dnia 20.08.2021 r.","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 7,0) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 重量法 范围 PB-01 wersja 02 z dnia 20.08.2021 r.","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9a9f1c10c8ce825a06a","lab_id":"69ad52a3de79e566650fb9a1","country":"PL","accr_number":"AB 1803","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(3,0 – 60,0) %"}],"parameters_en":[{"name":"Range","range":"(3,0 – 60,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (3,0 – 60,0) %\nMetoda wagowa","reference":"PB-02 wersja 02 z dnia 20.08.2021 r.","norm_bases":["PB-02 wersja 02 z dnia 20.08.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (3,0 – 60,0) %\nMetoda wagowa PB-02 wersja 02 z dnia 20.08.2021 r. Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (3,0 – 60,0) %\nMetoda wagowa PB-02 wersja 02 z dnia 20.08.2021 r.","categories":["petro"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Ash content Gravimetric method Range PB-02 wersja 02 z dnia 20.08.2021 r.","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(3,0 – 60,0) %"}],"search_zh":"固体燃料：烟煤 灰分含量 重量法 范围 PB-02 wersja 02 z dnia 20.08.2021 r.","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9a9f1c10c8ce825a06b","lab_id":"69ad52a3de79e566650fb9a1","country":"PL","accr_number":"AB 1803","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Ciepło spalania","methodology_en":"Gross calorific value","parameters":[{"name":"Zakres","range":"(14000 – 35000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(14000 – 35000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"technique_en":"Calorimetric method","computed":[],"computed_en":[],"activity":"Ciepło spalania\nZakres:\nZakres (14000 – 35000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-81/G-04513","norm_bases":["PN-81/G-04513"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania\nZakres:\nZakres (14000 – 35000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-81/G-04513 Paliwa stale: wegiel kamienny Cieplo spalania\nZakres:\nZakres (14000 – 35000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-81/G-04513","categories":["petro"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-81/G-04513","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(14000 – 35000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：烟煤 高位发热量 量热法 范围 低位发热量（计算值） PN-81/G-04513","technique_zh":"量热法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9a9f1c10c8ce825a06c","lab_id":"69ad52a3de79e566650fb9a1","country":"PL","accr_number":"AB 1803","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(2,0 – 65,0) %"}],"parameters_en":[{"name":"Range","range":"(2,0 – 65,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (2,0 – 65,0) %\nMetoda wagowa","reference":"PB-01 wersja 02 z dnia 20.08.2021 r.","norm_bases":["PB-01 wersja 02 z dnia 20.08.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Zawartość wilgoci całkowitej\nZakres (2,0 – 65,0) %\nMetoda wagowa PB-01 wersja 02 z dnia 20.08.2021 r. Paliwa stale: biomasa stala - biopaliwo stale Zawartosc wilgoci calkowitej\nZakres (2,0 – 65,0) %\nMetoda wagowa PB-01 wersja 02 z dnia 20.08.2021 r.","categories":["petro"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass - solid biofuel Total moisture content Gravimetric method Range PB-01 wersja 02 z dnia 20.08.2021 r.","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(2,0 – 65,0) %"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 全水分含量 重量法 范围 PB-01 wersja 02 z dnia 20.08.2021 r.","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"},{"_id":"6a5dc9a9f1c10c8ce825a06d","lab_id":"69ad52a3de79e566650fb9a1","country":"PL","accr_number":"AB 1803","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology":"Zawartość wilgoci w próbce analitycznej","methodology_en":"Moisture content in the analytical sample","parameters":[{"name":"Zakres","range":"(1,0 – 10,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 10,0) %\nMetoda wagowa","reference":"PB-01 wersja 02 z dnia 20.08.2021 r.","norm_bases":["PB-01 wersja 02 z dnia 20.08.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 10,0) %\nMetoda wagowa PB-01 wersja 02 z dnia 20.08.2021 r. Paliwa stale: biomasa stala - biopaliwo stale Zawartosc wilgoci w probce analitycznej\nZakres (1,0 – 10,0) %\nMetoda wagowa PB-01 wersja 02 z dnia 20.08.2021 r.","categories":["petro"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass - solid biofuel Moisture content in the analytical sample Gravimetric method Range PB-01 wersja 02 z dnia 20.08.2021 r.","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 10,0) %"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 分析样品水分含量 重量法 范围 PB-01 wersja 02 z dnia 20.08.2021 r.","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"},{"_id":"6a5dc9a9f1c10c8ce825a06e","lab_id":"69ad52a3de79e566650fb9a1","country":"PL","accr_number":"AB 1803","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(0,2 – 35,0) %"}],"parameters_en":[{"name":"Range","range":"(0,2 – 35,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (0,2 – 35,0) %\nMetoda wagowa","reference":"PB-02 wersja 02 z dnia 20.08.2021 r.","norm_bases":["PB-02 wersja 02 z dnia 20.08.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Zawartość popiołu\nZakres (0,2 – 35,0) %\nMetoda wagowa PB-02 wersja 02 z dnia 20.08.2021 r. Paliwa stale: biomasa stala - biopaliwo stale Zawartosc popiolu\nZakres (0,2 – 35,0) %\nMetoda wagowa PB-02 wersja 02 z dnia 20.08.2021 r.","categories":["petro"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass - solid biofuel Ash content Gravimetric method Range PB-02 wersja 02 z dnia 20.08.2021 r.","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,2 – 35,0) %"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 灰分含量 重量法 范围 PB-02 wersja 02 z dnia 20.08.2021 r.","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"},{"_id":"6a5dc9a9f1c10c8ce825a06f","lab_id":"69ad52a3de79e566650fb9a1","country":"PL","accr_number":"AB 1803","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology":"Ciepło spalania","methodology_en":"Gross calorific value","parameters":[{"name":"Zakres","range":"(14000 – 30000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(14000 – 30000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"technique_en":"Calorimetric method","computed":[],"computed_en":[],"activity":"Ciepło spalania\nZakres:\nZakres (14000 – 30000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-81/G-04513","norm_bases":["PN-81/G-04513"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Ciepło spalania\nZakres:\nZakres (14000 – 30000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-81/G-04513 Paliwa stale: biomasa stala - biopaliwo stale Cieplo spalania\nZakres:\nZakres (14000 – 30000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-81/G-04513","categories":["petro"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass - solid biofuel Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-81/G-04513","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(14000 – 30000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 高位发热量 量热法 范围 低位发热量（计算值） PN-81/G-04513","technique_zh":"量热法","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"}],"has_pdf":true}