{"lab":{"_id":"69ad52a3de79e566650fb993","country":"PL","accr_number":"AB 1795","accr_body":"PCA","address":"LABORATORIUM HIGIENY PRACY, ul. Stefana Okrzei 18, 64-920 Piła","categories":["environment","construction"],"city":"Piła","imported_at":"2026-03-08T10:42:43.265Z","methods_count":18,"name":"TECHNI-LAB Maciej Pszczoła","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1795.pdf"],"scope_summary":"","search_text":"techni-lab maciej pszczoła laboratorium higieny pracy, ul. stefana okrzei 18, 64-920 piła environment materials construction electronics other metrology","status":"active","updated_at":"2026-03-08T14:50:55.784Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:03:56.156Z","location":{"type":"Point","coordinates":[16.7385,53.151]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201795,podmiot.html","fields_of_testing":[{"codes":"C/33","pl":"Badania chemiczne – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests - working environment (harmful factors - air),"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, oświetlenie, drgania, mikroklimat)","en":"Tests concerning environmental engineering (environmental and climatic) - working environment (harmful and nuisance factors - noise, lighting, vibration, microclimate),"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling - working environment (harmful factors - air)"},{"codes":"P/33","pl":"Pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Sampling - working environment (harmful factors - air)"}],"issue":{"no":"7","date":"10.06.2026"},"parse_date":"2026-08-13T08:03:56.156Z","parse_source":"agent-claude-code","map_coord":[53.149352,16.727805],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM HIGIENY PRACY","address":"ul. Stefana Okrzei 18, 64-920 Piła","city":"Piła","postal":"64-920"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/06658afa489deb2de9254c0e599caf5c/AB%201795.pdf","has_en":true,"category_counts":{"environment":18,"construction":2,"materials":1},"category_scores":{"environment":15.43,"construction":0.19,"materials":0.05},"has_zh":true},"methods":[{"_id":"6a7d7a6c0636ba417e41b4f0","lab_id":"69ad52a3de79e566650fb993","country":"PL","accr_number":"AB 1795","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"},{"name":"substancje organiczne,"},{"name":"substancje nieorganiczne – frakcja wdychalna – frakcja respirabilna"},{"name":"metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne,\nsubstancje nieorganiczne – frakcja wdychalna – frakcja respirabilna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002 + Az1:2004"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne,\nsubstancje nieorganiczne – frakcja wdychalna – frakcja respirabilna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne,\nsubstancje nieorganiczne – frakcja wdychalna – frakcja respirabilna\nmetale i ich zwiazki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 + Az1:2004","categories":["materials","environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents – inhalable fraction – respirable fraction"},{"name":"organic substances,"},{"name":"inorganic substances – inhalable fraction – respirable fraction"},{"name":"metals and their compounds, including – inhalable fraction – respirable fraction"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents – inhalable fraction – respirable fraction organic substances, inorganic substances – inhalable fraction – respirable fraction metals and their compounds, including – inhalable fraction – respirable fraction PN-Z-04008-7:2002 + Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment – air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因素 — 可吸入组分 — 呼吸性组分 有机物质， 金属及其化合物，包括 — 可吸入组分 — 呼吸性组分 PN-Z-04008-7:2002 + Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"},{"name":"有机物质，"},{"name":"substancje nieorganiczne – frakcja wdychalna – frakcja respirabilna"},{"name":"金属及其化合物，包括 — 可吸入组分 — 呼吸性组分"}]},{"_id":"6a7d7a6c0636ba417e41b4f1","lab_id":"69ad52a3de79e566650fb993","country":"PL","accr_number":"AB 1795","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002 + Az1:2004"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 + Az1:2004","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment – air Exposure index (calculated) PN-Z-04008-7:2002 + Az1:2004","test_object_en":"Workplace environment – air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002 + Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a7d7a6c0636ba417e41b4f2","lab_id":"69ad52a3de79e566650fb993","country":"PL","accr_number":"AB 1795","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Sadza techniczna"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,18 – 16) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,18 – 16) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,18 – 16) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,18 – 16) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents - inhalable fraction:","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Carbon black"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Range","range":"(0,18 – 16) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents - inhalable fraction: Gravimetric method Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,18 – 16) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分： 重量法 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分："},{"_id":"6a7d7a6c0636ba417e41b4f3","lab_id":"69ad52a3de79e566650fb993","country":"PL","accr_number":"AB 1795","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,16 – 15) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,16 – 15) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,16 – 15) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nTalk\nWegiel (kamienny, brunatny)\nZakres (0,16 – 15) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents - respirable fraction:","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,16 – 15) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents - respirable fraction: Gravimetric method Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,16 – 15) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害健康的粉尘因子浓度 － 呼吸性粉尘： 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害健康的粉尘因子浓度 － 呼吸性粉尘："},{"_id":"6a7d7a6c0636ba417e41b4f4","lab_id":"69ad52a3de79e566650fb993","country":"PL","accr_number":"AB 1795","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie gazów","parameters":[{"name":"CO","range":"(2,3 – 232) mg/m3"},{"name":"Zakres","range":"(2 – 200) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie gazów\nZakres:\nCO (2,3 – 232) mg/m3\nZakres (2 – 200) ppm\nMetoda elektrochemiczna","reference":"Procedura Badawcza PB-02, wydanie 2 z dnia 23.03.2026 r.","norm_bases":["Procedura Badawcza PB-02, wydanie 2 z dnia 23.03.2026 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie gazów\nZakres:\nCO (2,3 – 232) mg/m3\nZakres (2 – 200) ppm\nMetoda elektrochemiczna Procedura Badawcza PB-02, wydanie 2 z dnia 23.03.2026 r. Srodowisko pracy − powietrze Stezenie gazow\nZakres:\nCO (2,3 – 232) mg/m3\nZakres (2 – 200) ppm\nMetoda elektrochemiczna Procedura Badawcza PB-02, wydanie 2 z dnia 23.03.2026 r.","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas concentrations","parameters_en":[{"name":"CO","range":"(2,3 – 232) mg/m3"},{"name":"Range","range":"(2 – 200) ppm"}],"search_en":"Workplace environment − air Gas concentrations Electrochemical method CO Range Procedura Badawcza PB-02, wydanie 2 z dnia 23.03.2026 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"CO","range":"(2,3 – 232) mg/m3"},{"name":"范围","range":"(2 – 200) ppm"}],"search_zh":"工作环境 − 空气 气体浓度 电化学法 CO 范围 Procedura Badawcza PB-02, wydanie 2 z dnia 23.03.2026 r.","technique_zh":"电化学法","test_object_zh":"工作环境 − 空气","methodology_zh":"气体浓度"},{"_id":"6a7d7a6c0636ba417e41b4f5","lab_id":"69ad52a3de79e566650fb993","country":"PL","accr_number":"AB 1795","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Wskaźniki narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźniki narażenia (z obliczeń)","reference":"Procedura Badawcza PB-02, wydanie 2 z dnia 23.03.2026 r.","norm_bases":["Procedura Badawcza PB-02, wydanie 2 z dnia 23.03.2026 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Wskaźniki narażenia (z obliczeń) Procedura Badawcza PB-02, wydanie 2 z dnia 23.03.2026 r. Srodowisko pracy − powietrze Wskazniki narazenia (z obliczen) Procedura Badawcza PB-02, wydanie 2 z dnia 23.03.2026 r.","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure indices (calculated)","search_en":"Workplace environment − air Exposure indices (calculated) Procedura Badawcza PB-02, wydanie 2 z dnia 23.03.2026 r.","test_object_en":"Workplace environment − air","search_zh":"工作环境 − 空气 暴露指数（计算值） Procedura Badawcza PB-02, wydanie 2 z dnia 23.03.2026 r.","test_object_zh":"工作环境 − 空气","methodology_zh":"暴露指数（计算值）"},{"_id":"6a7d7a6c0636ba417e41b4f6","lab_id":"69ad52a3de79e566650fb993","country":"PL","accr_number":"AB 1795","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Szczytowy poziom dźwięku C","parameters":[{"name":"Zakres","range":"(29 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Szczytowy poziom dźwięku C\nZakres (29 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 – punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 – punkt 11"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Szczytowy poziom dźwięku C\nZakres (29 – 135) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 – punkt 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A Szczytowy poziom dzwieku C\nZakres (29 – 135) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 - punkt 10 i strategie 3 – punkt 11","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level C-weighted peak sound level","parameters_en":[{"name":"Range","range":"(29 – 135) dB"}],"search_en":"Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level C-weighted peak sound level Direct measurement method Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 – punkt 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise","parameters_zh":[{"name":"范围","range":"(29 – 135) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 C 计权峰值声级 直接测量法 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 – punkt 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","methodology_zh":"A 计权等效声级 A 计权最大声级 C 计权峰值声级"},{"_id":"6a7d7a6c0636ba417e41b4f7","lab_id":"69ad52a3de79e566650fb993","country":"PL","accr_number":"AB 1795","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 – punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 – punkt 11"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 – punkt 11 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 - punkt 10 i strategie 3 – punkt 11","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment – noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 – punkt 11","test_object_en":"Workplace environment – noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 – punkt 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a7d7a6c0636ba417e41b4f8","lab_id":"69ad52a3de79e566650fb993","country":"PL","accr_number":"AB 1795","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 5 000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03 | PB-01 wydanie 2 z dnia 20.04.2021 r.","norm_bases":["PN-83/E-04040.03","PB-01 wydanie 2 z dnia 20.04.2021 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 | PB-01 wydanie 2 z dnia 20.04.2021 r. Srodowisko pracy − oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03 | PB-01 wydanie 2 z dnia 20.04.2021 r.","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 – 5 000) lx"}],"search_en":"Workplace environment − indoor electric lighting Illuminance Direct measurement method Range PN-83/E-04040.03 | PB-01 wydanie 2 z dnia 20.04.2021 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 5 000) lx"}],"search_zh":"工作场所环境 − 室内电气照明 照度 直接测量法 范围 PN-83/E-04040.03 | PB-01 wydanie 2 z dnia 20.04.2021 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 室内电气照明"},{"_id":"6a7d7a6c0636ba417e41b4f9","lab_id":"69ad52a3de79e566650fb993","country":"PL","accr_number":"AB 1795","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03 | PB-01 wydanie 2 z dnia 20.04.2021 r.","norm_bases":["PN-83/E-04040.03","PB-01 wydanie 2 z dnia 20.04.2021 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 | PB-01 wydanie 2 z dnia 20.04.2021 r. Srodowisko pracy − oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03 | PB-01 wydanie 2 z dnia 20.04.2021 r.","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment − indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03 | PB-01 wydanie 2 z dnia 20.04.2021 r.","test_object_en":"Workplace environment − indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 − 室内电气照明 照度均匀度（计算值） PN-83/E-04040.03 | PB-01 wydanie 2 z dnia 20.04.2021 r.","test_object_zh":"工作场所环境 − 室内电气照明"},{"_id":"6a7d7a6c0636ba417e41b4fa","lab_id":"69ad52a3de79e566650fb993","country":"PL","accr_number":"AB 1795","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(0 – 30) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(0 – 30) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 – 80) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (0 – 30) °C\nTemperatura poczernionej kuli\nZakres (0 – 30) °C\nWilgotność powietrza\nZakres (20 – 80) %\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (0 – 30) °C\nTemperatura poczernionej kuli\nZakres (0 – 30) °C\nWilgotność powietrza\nZakres (20 – 80) %\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (0 – 30) °C\nTemperatura poczernionej kuli\nZakres (0 – 30) °C\nWilgotnosc powietrza\nZakres (20 – 80) %\nPredkosc powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(0 – 30) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(0 – 30) °C"},{"name":"Air humidity"},{"name":"Range","range":"(20 – 80) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 5,0) m/s"}],"search_en":"Workplace environment - moderate microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2006+Ap2:2016-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment - moderate microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(0 – 30) °C"},{"name":"黑球温度"},{"name":"范围","range":"(0 – 30) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20 – 80) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 5,0) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006+Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a7d7a6c0636ba417e41b4fb","lab_id":"69ad52a3de79e566650fb993","country":"PL","accr_number":"AB 1795","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PMV index, PPD index (calculated)","search_en":"Workplace environment - moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006+Ap2:2016-04","test_object_en":"Workplace environment - moderate microclimate","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 — 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2006+Ap2:2016-04","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a7d7a6c0636ba417e41b4fc","lab_id":"69ad52a3de79e566650fb993","country":"PL","accr_number":"AB 1795","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 – 50) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(10 – 50) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 50) °C"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 50) °C\nTemperatura wilgotna naturalna\nZakres (10 – 50) °C\nTemperatura poczernionej kuli\nZakres (10 – 50) °C\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 7243:2018-01 | PN-EN ISO 7243:2018-01/ Ap2:2020-04","norm_bases":["PN-EN 7243:2018-01","PN-EN ISO 7243:2018-01/ Ap2:2020-04"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (10 – 50) °C\nTemperatura wilgotna naturalna\nZakres (10 – 50) °C\nTemperatura poczernionej kuli\nZakres (10 – 50) °C\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN 7243:2018-01 | PN-EN ISO 7243:2018-01/ Ap2:2020-04 Srodowisko pracy - mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (10 – 50) °C\nTemperatura wilgotna naturalna\nZakres (10 – 50) °C\nTemperatura poczernionej kuli\nZakres (10 – 50) °C\nPredkosc powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezposrednia PN-EN 7243:2018-01 | PN-EN ISO 7243:2018-01/ Ap2:2020-04","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 – 50) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(10 – 50) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 – 50) °C"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 5,0) m/s"}],"search_en":"Workplace environment - hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range Air velocity Range PN-EN 7243:2018-01 | PN-EN ISO 7243:2018-01/ Ap2:2020-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 50) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(10 – 50) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 – 50) °C"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 5,0) m/s"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 空气流速 范围 PN-EN 7243:2018-01 | PN-EN ISO 7243:2018-01/ Ap2:2020-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a7d7a6c0636ba417e41b4fd","lab_id":"69ad52a3de79e566650fb993","country":"PL","accr_number":"AB 1795","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN 7243:2018-01 | PN-EN ISO 7243:2018-01/ Ap2:2020-04","norm_bases":["PN-EN 7243:2018-01","PN-EN ISO 7243:2018-01/ Ap2:2020-04"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN 7243:2018-01 | PN-EN ISO 7243:2018-01/ Ap2:2020-04 Srodowisko pracy - mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN 7243:2018-01 | PN-EN ISO 7243:2018-01/ Ap2:2020-04","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"Workplace environment - hot microclimate WBGT index, WBGTeff index (calculated) PN-EN 7243:2018-01 | PN-EN ISO 7243:2018-01/ Ap2:2020-04","test_object_en":"Workplace environment - hot microclimate","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PN-EN 7243:2018-01 | PN-EN ISO 7243:2018-01/ Ap2:2020-04","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a7d7a6c0636ba417e41b4fe","lab_id":"69ad52a3de79e566650fb993","country":"PL","accr_number":"AB 1795","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,64 − 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,64 − 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN-ISO 5349-2:2004/ A1:2015-11","norm_bases":["PN-EN-ISO 5349-1:2004","PN-EN-ISO 5349-2:2004","PN-EN-ISO 5349-2:2004/ A1:2015-11"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,64 − 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN-ISO 5349-2:2004/ A1:2015-11 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,64 − 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN-ISO 5349-2:2004/ A1:2015-11","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,64 − 100) m/s2"}],"search_en":"Workplace environment - hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN-ISO 5349-2:2004/ A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,64 − 100) m/s2"}],"search_zh":"工作场所环境 — 手传振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN-ISO 5349-2:2004/ A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a7d7a6c0636ba417e41b4ff","lab_id":"69ad52a3de79e566650fb993","country":"PL","accr_number":"AB 1795","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN-ISO 5349-2:2004/ A1:2015-11","norm_bases":["PN-EN-ISO 5349-1:2004","PN-EN-ISO 5349-2:2004","PN-EN-ISO 5349-2:2004/ A1:2015-11"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN-ISO 5349-2:2004/ A1:2015-11 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN-ISO 5349-2:2004/ A1:2015-11","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment - hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN-ISO 5349-2:2004/ A1:2015-11","test_object_en":"Workplace environment - hand-arm vibration","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）","search_zh":"工作场所环境 — 手传振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN-ISO 5349-2:2004/ A1:2015-11","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a7d7a6c0636ba417e41b500","lab_id":"69ad52a3de79e566650fb993","country":"PL","accr_number":"AB 1795","accr_body":"PCA","test_object":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,10 − 20) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,10 − 20) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,10 − 20) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy - drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,10 − 20) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,10 − 20) m/s2"}],"search_en":"Workplace environment - whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment - whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,10 − 20) m/s2"}],"search_zh":"工作场所环境 — 全身振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a7d7a6c0636ba417e41b501","lab_id":"69ad52a3de79e566650fb993","country":"PL","accr_number":"AB 1795","accr_body":"PCA","test_object":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy - drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz) (calculated)","search_en":"Workplace environment - whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz) (calculated) PN-EN 14253+A1:2011","test_object_en":"Workplace environment - whole-body vibration","search_zh":"工作场所环境 — 全身振动 日暴露量，以考虑相应系数后三个方向分量（1,4awx、1,4awy、awz）所测定的振动加速度中占主导的频率计权有效振动加速度的8小时能量等效值表示；持续30分钟及以下的暴露量，以考虑相应系数后三个方向分量（1,4awx、1,4awy、awz）所测定的振动加速度中占主导的频率计权有效振动加速度表示（由计算得出） PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动","methodology_zh":"日暴露量，以考虑相应系数后三个方向分量（1,4awx、1,4awy、awz）所测定的振动加速度中占主导的频率计权有效振动加速度的8小时能量等效值表示；持续30分钟及以下的暴露量，以考虑相应系数后三个方向分量（1,4awx、1,4awy、awz）所测定的振动加速度中占主导的频率计权有效振动加速度表示（由计算得出）"}],"has_pdf":true}