{"lab":{"_id":"69ad52a3de79e566650fb98d","accr_number":"AB 1792","country":"PL","accr_body":"PCA","address":"BFL FIRE TESTING LABORATORY, ul. Banińska 8, 80-209 Tuchom","categories":["water"],"city":"Tuchom","imported_at":"2026-03-08T10:42:43.265Z","methods_count":30,"name":"BALTIC FIRE LABORATORY Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1792.pdf"],"scope_summary":"","search_text":"baltic fire laboratory sp. z o.o. bfl fire testing laboratory, ul. banińska 8, 80-209 tuchom materials other water environment metrology","status":"active","updated_at":"2026-03-08T14:50:55.583Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T15:11:52.500Z","email_confidence":"high","email_mx":true,"email_source":"https://www.bafilab.com/","fields_of_testing":[{"codes":"H/17","pl":"Badania ogniowe wyrobów innych","en":"Fire tests of other products"}],"issue":{"no":"9","date":"30.06.2026"},"parse_date":"2026-08-17T15:11:52.500Z","parse_source":"agent-claude-code","map_coord":[54.419979,18.384784],"map_geo":"nominatim-street","scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/a0b9de04ff19d311bb8c3fb7848d3620/AB%201792.pdf","has_en":true,"category_counts":{"water":21,"other":9,"materials":1},"category_scores":{"water":14.23,"other":2.61,"materials":0.03},"has_zh":true},"methods":[{"_id":"6a8324b8884ede9a1b2c4f67","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist","methodology":"Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression","parameters":[{"name":"Temperatura / Temperature"},{"name":"Stężenie (O2) / Concentration (O2)"},{"name":"Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)"},{"name":"Ciśnienie / Pressure"},{"name":"Czas / Time"},{"name":"Obszar uszkodzenia, % / Damaged area, %"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time\nObszar uszkodzenia, % / Damaged area, %","reference":"IMO Res. A.800(19) ze zmianami w IMO MSC.265(84) Appendix 2 / IMO Res. A.800(19) with amendments as set out in IMO MSC.265(84) Appendix 2 | PN-EN 14972-1:2021, Annex A | PN-EN 14972-3:2022-01 | PN EN 14972-4:2024 | PN-EN 14972-10:2022-09 | UL 2167 (2021) p. 44, 45, 46, 48, 49, 50 | VdS 3883-1:2020-06 | VdS 3883-2:2020-06 | VdS 3883-5:2020-06 | FM Approval Standard Class 5560:2021 Appendix P","norm_bases":["IMO Res. A.800(19) ze zmianami w IMO MSC.265(84) Appendix 2 / IMO Res. A.800(19) with amendments as set out in IMO MSC.265(84) Appendix 2","PN-EN 14972-1:2021, Annex A","PN-EN 14972-3:2022-01","PN EN 14972-4:2024","PN-EN 14972-10:2022-09","UL 2167 (2021) p. 44, 45, 46, 48, 49, 50","VdS 3883-1:2020-06","VdS 3883-2:2020-06","VdS 3883-5:2020-06","FM Approval Standard Class 5560:2021 Appendix P"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time\nObszar uszkodzenia, % / Damaged area, % IMO Res. A.800(19) ze zmianami w IMO MSC.265(84) Appendix 2 / IMO Res. A.800(19) with amendments as set out in IMO MSC.265(84) Appendix 2 | PN-EN 14972-1:2021, Annex A | PN-EN 14972-3:2022-01 | PN EN 14972-4:2024 | PN-EN 14972-10:2022-09 | UL 2167 (2021) p. 44, 45, 46, 48, 49, 50 | VdS 3883-1:2020-06 | VdS 3883-2:2020-06 | VdS 3883-5:2020-06 | FM Approval Standard Class 5560:2021 Appendix P Stale wodne systemy przeciwpozarowe - mgla wodna / Fixed water-based firefighting systems - water mist Skutecznosc gaszenia i tlumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nTemperatura / Temperature\nStezenie (O2) / Concentration (O2)\nObjetosciowe natezenie przeplywu (metoda bezposrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCisnienie / Pressure\nCzas / Time\nObszar uszkodzenia, % / Damaged area, % IMO Res. A.800(19) ze zmianami w IMO MSC.265(84) Appendix 2 / IMO Res. A.800(19) with amendments as set out in IMO MSC.265(84) Appendix 2 | PN-EN 14972-1:2021, Annex A | PN-EN 14972-3:2022-01 | PN EN 14972-4:2024 | PN-EN 14972-10:2022-09 | UL 2167 (2021) p. 44, 45, 46, 48, 49, 50 | VdS 3883-1:2020-06 | VdS 3883-2:2020-06 | VdS 3883-5:2020-06 | FM Approval Standard Class 5560:2021 Appendix P","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents IMO Res. A.800(19) ze zmianami w IMO MSC.265(84) Appendix 2 / IMO Res. A.800(19) with amendments as set out in IMO MSC.265(84) Appendix 2 | PN-EN 14972-1:2021, Annex A | PN-EN 14972-3:2022-01 | PN EN 14972-4:2024 | PN-EN 14972-10:2022-09 | UL 2167 (2021) p. 44, 45, 46, 48, 49, 50 | VdS 3883-1:2020-06 | VdS 3883-2:2020-06 | VdS 3883-5:2020-06 | FM Approval Standard Class 5560:2021 Appendix P"},{"_id":"6a8324b8884ede9a1b2c4f68","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist","methodology":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment","parameters":[{"name":"Temperatura / Temperature"},{"name":"Stężenie (O2) / Concentration (O2)"},{"name":"Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)"},{"name":"Ciśnienie / Pressure"},{"name":"Czas / Time"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time","reference":"IMO MSC/Circ.1165 Appendix B ze zmianami w IMO MSC.1/Circ.1269 oraz IMO MSC.1/Circ.1386 / IMO MSC/Circ.1165 Appendix B with amendments as set out in IMO MSC.1/Circ.1269 and in IMO MSC.1/Circ.1386 | UL 2167 (2021) p. 43 | FM Approval Standard Class 5560:2021 Appendix E | FM Approval Standard Class 5560:2021 Appendix F | PN-EN 14972-8:2020-06 | PN-EN 14972-14:2022-02 | PN-EN 14972-15:2022-02 | PN-EN 14972-9:2020-06","norm_bases":["IMO MSC/Circ.1165 Appendix B ze zmianami w IMO MSC.1/Circ.1269 oraz IMO MSC.1/Circ.1386 / IMO MSC/Circ.1165 Appendix B with amendments as set out in IMO MSC.1/Circ.1269 and in IMO MSC.1/Circ.1386","UL 2167 (2021) p. 43","FM Approval Standard Class 5560:2021 Appendix E","FM Approval Standard Class 5560:2021 Appendix F","PN-EN 14972-8:2020-06","PN-EN 14972-14:2022-02","PN-EN 14972-15:2022-02","PN-EN 14972-9:2020-06"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time IMO MSC/Circ.1165 Appendix B ze zmianami w IMO MSC.1/Circ.1269 oraz IMO MSC.1/Circ.1386 / IMO MSC/Circ.1165 Appendix B with amendments as set out in IMO MSC.1/Circ.1269 and in IMO MSC.1/Circ.1386 | UL 2167 (2021) p. 43 | FM Approval Standard Class 5560:2021 Appendix E | FM Approval Standard Class 5560:2021 Appendix F | PN-EN 14972-8:2020-06 | PN-EN 14972-14:2022-02 | PN-EN 14972-15:2022-02 | PN-EN 14972-9:2020-06 Stale wodne systemy przeciwpozarowe - mgla wodna / Fixed water-based firefighting systems - water mist Skutecznosc gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStezenie (O2) / Concentration (O2)\nObjetosciowe natezenie przeplywu (metoda bezposrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCisnienie / Pressure\nCzas / Time IMO MSC/Circ.1165 Appendix B ze zmianami w IMO MSC.1/Circ.1269 oraz IMO MSC.1/Circ.1386 / IMO MSC/Circ.1165 Appendix B with amendments as set out in IMO MSC.1/Circ.1269 and in IMO MSC.1/Circ.1386 | UL 2167 (2021) p. 43 | FM Approval Standard Class 5560:2021 Appendix E | FM Approval Standard Class 5560:2021 Appendix F | PN-EN 14972-8:2020-06 | PN-EN 14972-14:2022-02 | PN-EN 14972-15:2022-02 | PN-EN 14972-9:2020-06","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents IMO MSC/Circ.1165 Appendix B ze zmianami w IMO MSC.1/Circ.1269 oraz IMO MSC.1/Circ.1386 / IMO MSC/Circ.1165 Appendix B with amendments as set out in IMO MSC.1/Circ.1269 and in IMO MSC.1/Circ.1386 | UL 2167 (2021) p. 43 | FM Approval Standard Class 5560:2021 Appendix E | FM Approval Standard Class 5560:2021 Appendix F | PN-EN 14972-8:2020-06 | PN-EN 14972-14:2022-02 | PN-EN 14972-15:2022-02 | PN-EN 14972-9:2020-06"},{"_id":"6a8324b8884ede9a1b2c4f69","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist","methodology":"Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression","parameters":[{"name":"Temperatura / Temperature"},{"name":"Stężenie (O2) / Concentration (O2)"},{"name":"Stężenie (CO) / Concentration (CO)"},{"name":"Stężenie (CO2) / Concentration (CO2)"},{"name":"Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)"},{"name":"Ciśnienie / Pressure"},{"name":"Czas / Time"},{"name":"Obszar uszkodzenia, % / Damaged area, %"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nStężenie (CO) / Concentration (CO)\nStężenie (CO2) / Concentration (CO2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time\nObszar uszkodzenia, % / Damaged area, %","reference":"PN EN 14972-7:2024","norm_bases":["PN EN 14972-7:2024"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nStężenie (CO) / Concentration (CO)\nStężenie (CO2) / Concentration (CO2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time\nObszar uszkodzenia, % / Damaged area, % PN EN 14972-7:2024 Stale wodne systemy przeciwpozarowe - mgla wodna / Fixed water-based firefighting systems - water mist Skutecznosc gaszenia i tlumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nTemperatura / Temperature\nStezenie (O2) / Concentration (O2)\nStezenie (CO) / Concentration (CO)\nStezenie (CO2) / Concentration (CO2)\nObjetosciowe natezenie przeplywu (metoda bezposrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCisnienie / Pressure\nCzas / Time\nObszar uszkodzenia, % / Damaged area, % PN EN 14972-7:2024","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents PN EN 14972-7:2024"},{"_id":"6a8324b8884ede9a1b2c4f6a","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist","methodology":"Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression","parameters":[{"name":"Rozprzestrzeniane się płomienia / Flame spread"},{"name":"Temperatura / Temperature"},{"name":"Stężenie (O2) / Concentration (O2)"},{"name":"Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)"},{"name":"Ciśnienie / Pressure"},{"name":"Czas / Time"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nRozprzestrzeniane się płomienia / Flame spread\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time","reference":"IMO MSC.1/Circ.1268","norm_bases":["IMO MSC.1/Circ.1268"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nRozprzestrzeniane się płomienia / Flame spread\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time IMO MSC.1/Circ.1268 Stale wodne systemy przeciwpozarowe - mgla wodna / Fixed water-based firefighting systems - water mist Skutecznosc gaszenia i tlumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nRozprzestrzeniane sie plomienia / Flame spread\nTemperatura / Temperature\nStezenie (O2) / Concentration (O2)\nObjetosciowe natezenie przeplywu (metoda bezposrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCisnienie / Pressure\nCzas / Time IMO MSC.1/Circ.1268","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents IMO MSC.1/Circ.1268"},{"_id":"6a8324b8884ede9a1b2c4f6b","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist","methodology":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment","parameters":[{"name":"Rozprzestrzeniane się płomienia / Flame Spread"},{"name":"Temperatura / Temperature"},{"name":"Stężenie (O2) / Concentration (O2)"},{"name":"Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)"},{"name":"Ciśnienie / Pressure"},{"name":"Czas / Time"},{"name":"Zakres","range":"t > 1 s"},{"name":"Range","range":"t > 1s"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nRozprzestrzeniane się płomienia / Flame Spread\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time\nZakres t > 1 s\nRange t > 1s","reference":"IMO MSC.1/Circ.1387 Appendix","norm_bases":["IMO MSC.1/Circ.1387 Appendix"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nRozprzestrzeniane się płomienia / Flame Spread\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time\nZakres t > 1 s\nRange t > 1s IMO MSC.1/Circ.1387 Appendix Stale wodne systemy przeciwpozarowe - mgla wodna / Fixed water-based firefighting systems - water mist Skutecznosc gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nRozprzestrzeniane sie plomienia / Flame Spread\nTemperatura / Temperature\nStezenie (O2) / Concentration (O2)\nObjetosciowe natezenie przeplywu (metoda bezposrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCisnienie / Pressure\nCzas / Time\nZakres t > 1 s\nRange t > 1s IMO MSC.1/Circ.1387 Appendix","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Rozprzestrzeniane się płomienia / Flame Spread"},{"name":"Temperatura / Temperature"},{"name":"Stężenie (O2) / Concentration (O2)"},{"name":"Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)"},{"name":"Ciśnienie / Pressure"},{"name":"Czas / Time"},{"name":"Range","range":"t > 1 s"},{"name":"Range","range":"t > 1s"}],"search_en":"Range Range Type of activity/ parameter/ characteristic tested Reference documents IMO MSC.1/Circ.1387 Appendix","parameters_zh":[{"name":"Rozprzestrzeniane się płomienia / Flame Spread"},{"name":"Temperatura / Temperature"},{"name":"Stężenie (O2) / Concentration (O2)"},{"name":"Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)"},{"name":"Ciśnienie / Pressure"},{"name":"Czas / Time"},{"name":"范围","range":"t > 1 s"},{"name":"范围","range":"t > 1s"}],"search_zh":"范围 范围 IMO MSC.1/Circ.1387 Appendix"},{"_id":"6a8324b8884ede9a1b2c4f6c","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist","methodology":"Skuteczność tłumienia ognia / Effectiveness of fire extinguishment","parameters":[{"name":"Rozprzestrzeniane się płomienia / Flame spread"},{"name":"Temperatura / Temperature"},{"name":"Stężenie (O2) / Concentration (O2)"},{"name":"Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)"},{"name":"Ciśnienie / Pressure"},{"name":"Czas / Time"},{"name":"Obszar uszkodzenia, % / Damaged area, %"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność tłumienia ognia / Effectiveness of fire extinguishment\nZakres:\nRozprzestrzeniane się płomienia / Flame spread\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time\nObszar uszkodzenia, % / Damaged area, %","reference":"IMO MSC.1/Circ.1430/Rev.03 Appendix | VdS 3883-4:2020-06 | PN-EN 14972-5:2024","norm_bases":["IMO MSC.1/Circ.1430/Rev.03 Appendix","VdS 3883-4:2020-06","PN-EN 14972-5:2024"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist Skuteczność tłumienia ognia / Effectiveness of fire extinguishment\nZakres:\nRozprzestrzeniane się płomienia / Flame spread\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time\nObszar uszkodzenia, % / Damaged area, % IMO MSC.1/Circ.1430/Rev.03 Appendix | VdS 3883-4:2020-06 | PN-EN 14972-5:2024 Stale wodne systemy przeciwpozarowe - mgla wodna / Fixed water-based firefighting systems - water mist Skutecznosc tlumienia ognia / Effectiveness of fire extinguishment\nZakres:\nRozprzestrzeniane sie plomienia / Flame spread\nTemperatura / Temperature\nStezenie (O2) / Concentration (O2)\nObjetosciowe natezenie przeplywu (metoda bezposrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCisnienie / Pressure\nCzas / Time\nObszar uszkodzenia, % / Damaged area, % IMO MSC.1/Circ.1430/Rev.03 Appendix | VdS 3883-4:2020-06 | PN-EN 14972-5:2024","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents IMO MSC.1/Circ.1430/Rev.03 Appendix | VdS 3883-4:2020-06 | PN-EN 14972-5:2024"},{"_id":"6a8324b8884ede9a1b2c4f6d","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Stałe wodne systemy przeciwpożarowe – systemy rurowe / Fixed water-based firefighting systems – piping systems","methodology":"Rozprzestrzeniane się płomienia / Flame Spread","parameters":[{"name":"Temperatura / Temperature"},{"name":"Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)"},{"name":"Ciśnienie / Pressure"},{"name":"Czas / Time"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Rozprzestrzeniane się płomienia / Flame Spread\nZakres:\nTemperatura / Temperature\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time","reference":"A.753(18) GUIDELINES FOR THE APPLICATION OF PLASTIC PIPES ON SHIPS","norm_bases":["A.753(18) GUIDELINES FOR THE APPLICATION OF PLASTIC PIPES ON SHIPS"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe wodne systemy przeciwpożarowe – systemy rurowe / Fixed water-based firefighting systems – piping systems Rozprzestrzeniane się płomienia / Flame Spread\nZakres:\nTemperatura / Temperature\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time A.753(18) GUIDELINES FOR THE APPLICATION OF PLASTIC PIPES ON SHIPS Stale wodne systemy przeciwpozarowe – systemy rurowe / Fixed water-based firefighting systems – piping systems Rozprzestrzeniane sie plomienia / Flame Spread\nZakres:\nTemperatura / Temperature\nObjetosciowe natezenie przeplywu (metoda bezposrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCisnienie / Pressure\nCzas / Time A.753(18) GUIDELINES FOR THE APPLICATION OF PLASTIC PIPES ON SHIPS","categories":["water","materials"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents A.753(18) GUIDELINES FOR THE APPLICATION OF PLASTIC PIPES ON SHIPS"},{"_id":"6a8324b8884ede9a1b2c4f6e","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist","methodology":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment","parameters":[{"name":"Rozprzestrzeniane się płomienia / Flame spread"},{"name":"Temperatura / Temperature"},{"name":"Stężenie (O2) / Concentration (O2)"},{"name":"Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)"},{"name":"Ciśnienie / Pressure"},{"name":"Czas / Time"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nRozprzestrzeniane się płomienia / Flame spread\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time","reference":"FM Approval Standard Class 5560:2021 Appendix M | FM Approval Standard Class 5560:2021 Appendix N","norm_bases":["FM Approval Standard Class 5560:2021 Appendix M","FM Approval Standard Class 5560:2021 Appendix N"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nRozprzestrzeniane się płomienia / Flame spread\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time FM Approval Standard Class 5560:2021 Appendix M | FM Approval Standard Class 5560:2021 Appendix N Stale wodne systemy przeciwpozarowe - mgla wodna / Fixed water-based firefighting systems - water mist Skutecznosc gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nRozprzestrzeniane sie plomienia / Flame spread\nTemperatura / Temperature\nStezenie (O2) / Concentration (O2)\nObjetosciowe natezenie przeplywu (metoda bezposrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCisnienie / Pressure\nCzas / Time FM Approval Standard Class 5560:2021 Appendix M | FM Approval Standard Class 5560:2021 Appendix N","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents FM Approval Standard Class 5560:2021 Appendix M | FM Approval Standard Class 5560:2021 Appendix N"},{"_id":"6a8324b8884ede9a1b2c4f6f","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist","methodology":"Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression","parameters":[{"name":"Temperatura / Temperature"},{"name":"Stężenie (O2) / Concentration (O2)"},{"name":"Objętościowe natężenie przepływu (metoda wagowa, metoda bezpośrednia) / Volumetric flow rate (direct method, weight method)"},{"name":"Ciśnienie / Pressure"},{"name":"Czas / Time"},{"name":"Obszar uszkodzenia, % / Damaged area, %"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda wagowa, metoda bezpośrednia) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time\nObszar uszkodzenia, % / Damaged area, %","reference":"VdS 3883-3:2020-06 | PN-EN 14972-6:2023-10","norm_bases":["VdS 3883-3:2020-06","PN-EN 14972-6:2023-10"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda wagowa, metoda bezpośrednia) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time\nObszar uszkodzenia, % / Damaged area, % VdS 3883-3:2020-06 | PN-EN 14972-6:2023-10 Stale wodne systemy przeciwpozarowe - mgla wodna / Fixed water-based firefighting systems - water mist Skutecznosc gaszenia i tlumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nTemperatura / Temperature\nStezenie (O2) / Concentration (O2)\nObjetosciowe natezenie przeplywu (metoda wagowa, metoda bezposrednia) / Volumetric flow rate (direct method, weight method)\nCisnienie / Pressure\nCzas / Time\nObszar uszkodzenia, % / Damaged area, % VdS 3883-3:2020-06 | PN-EN 14972-6:2023-10","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents VdS 3883-3:2020-06 | PN-EN 14972-6:2023-10"},{"_id":"6a8324b8884ede9a1b2c4f70","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist","methodology":"Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression","parameters":[{"name":"Temperatura / Temperature"},{"name":"Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)"},{"name":"Ciśnienie / Pressure"},{"name":"Czas / Time"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nTemperatura / Temperature\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time","reference":"VdS 3883-6:2020-06 | BS EN 14972-17:2025 | UL 2167 (2021) p. 47 | UL 2167A (2024) p. 23","norm_bases":["VdS 3883-6:2020-06","BS EN 14972-17:2025","UL 2167 (2021) p. 47","UL 2167A (2024) p. 23"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nTemperatura / Temperature\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time VdS 3883-6:2020-06 | BS EN 14972-17:2025 | UL 2167 (2021) p. 47 | UL 2167A (2024) p. 23 Stale wodne systemy przeciwpozarowe - mgla wodna / Fixed water-based firefighting systems - water mist Skutecznosc gaszenia i tlumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nTemperatura / Temperature\nObjetosciowe natezenie przeplywu (metoda bezposrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCisnienie / Pressure\nCzas / Time VdS 3883-6:2020-06 | BS EN 14972-17:2025 | UL 2167 (2021) p. 47 | UL 2167A (2024) p. 23","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents VdS 3883-6:2020-06 | BS EN 14972-17:2025 | UL 2167 (2021) p. 47 | UL 2167A (2024) p. 23"},{"_id":"6a8324b8884ede9a1b2c4f71","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist","methodology":"Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression","parameters":[{"name":"Temperatura / Temperature"},{"name":"Stężenie (O2) / Concentration (O2)"},{"name":"Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)"},{"name":"Ciśnienie / Pressure"},{"name":"Czas / Time"},{"name":"Obszar uszkodzenia, % / Damaged area, %"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time\nObszar uszkodzenia, % / Damaged area, %","reference":"VdS 3883-7:2020-06","norm_bases":["VdS 3883-7:2020-06"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time\nObszar uszkodzenia, % / Damaged area, % VdS 3883-7:2020-06 Stale wodne systemy przeciwpozarowe - mgla wodna / Fixed water-based firefighting systems - water mist Skutecznosc gaszenia i tlumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nTemperatura / Temperature\nStezenie (O2) / Concentration (O2)\nObjetosciowe natezenie przeplywu (metoda bezposrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCisnienie / Pressure\nCzas / Time\nObszar uszkodzenia, % / Damaged area, % VdS 3883-7:2020-06","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents VdS 3883-7:2020-06"},{"_id":"6a8324b8884ede9a1b2c4f72","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist","methodology":"Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression","parameters":[{"name":"Temperatura / Temperature"},{"name":"Stężenie (O2) / Concentration (O2)"},{"name":"Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)"},{"name":"Ciśnienie / Pressure"},{"name":"Czas / Time"},{"name":"Obszar uszkodzenia, % / Damaged area, %"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time\nObszar uszkodzenia, % / Damaged area, %","reference":"VdS 3883-8:2020-06 | PN EN 14972-11:2023-10","norm_bases":["VdS 3883-8:2020-06","PN EN 14972-11:2023-10"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time\nObszar uszkodzenia, % / Damaged area, % VdS 3883-8:2020-06 | PN EN 14972-11:2023-10 Stale wodne systemy przeciwpozarowe - mgla wodna / Fixed water-based firefighting systems - water mist Skutecznosc gaszenia i tlumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nTemperatura / Temperature\nStezenie (O2) / Concentration (O2)\nObjetosciowe natezenie przeplywu (metoda bezposrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCisnienie / Pressure\nCzas / Time\nObszar uszkodzenia, % / Damaged area, % VdS 3883-8:2020-06 | PN EN 14972-11:2023-10","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents VdS 3883-8:2020-06 | PN EN 14972-11:2023-10"},{"_id":"6a8324b8884ede9a1b2c4f73","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Aerosolowe systemy przeciwpożarowe, Generatory aerosolu / Fixed aerosol firefighting systems, Aerosol generators","methodology":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment","parameters":[{"name":"Temperatura / Temperature"},{"name":"Stężenie (O2) / Concentration (O2)"},{"name":"Stężenie (CO) / Concentration (CO)"},{"name":"Stężenie (CO2) / Concentration (CO2)"},{"name":"Ciśnienie (Pa) / Pressure (Pa)"},{"name":"Pomiar masy / Mass measurement"},{"name":"Czas / Time"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nStężenie (CO) / Concentration (CO)\nStężenie (CO2) / Concentration (CO2)\nCiśnienie (Pa) / Pressure (Pa)\nPomiar masy / Mass measurement\nCzas / Time","reference":"IMO MSC.1/Circ.1270 | ISO 15779:2011 Annex D","norm_bases":["IMO MSC.1/Circ.1270","ISO 15779:2011 Annex D"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Aerosolowe systemy przeciwpożarowe, Generatory aerosolu / Fixed aerosol firefighting systems, Aerosol generators Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nStężenie (CO) / Concentration (CO)\nStężenie (CO2) / Concentration (CO2)\nCiśnienie (Pa) / Pressure (Pa)\nPomiar masy / Mass measurement\nCzas / Time IMO MSC.1/Circ.1270 | ISO 15779:2011 Annex D Aerosolowe systemy przeciwpozarowe, Generatory aerosolu / Fixed aerosol firefighting systems, Aerosol generators Skutecznosc gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStezenie (O2) / Concentration (O2)\nStezenie (CO) / Concentration (CO)\nStezenie (CO2) / Concentration (CO2)\nCisnienie (Pa) / Pressure (Pa)\nPomiar masy / Mass measurement\nCzas / Time IMO MSC.1/Circ.1270 | ISO 15779:2011 Annex D","categories":["other"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents IMO MSC.1/Circ.1270 | ISO 15779:2011 Annex D"},{"_id":"6a8324b8884ede9a1b2c4f74","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Aerosolowe systemy przeciwpożarowe, Generatory aerosolu / Fixed aerosol firefighting systems, Aerosol generators","methodology":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment","parameters":[{"name":"Temperatura / Temperature"},{"name":"Stężenie (O2) / Concentration (O2)"},{"name":"Czas / Time"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nCzas / Time","reference":"UL2775 (2022) p. 49, 50, 51, 52","norm_bases":["UL2775 (2022) p. 49, 50, 51, 52"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Aerosolowe systemy przeciwpożarowe, Generatory aerosolu / Fixed aerosol firefighting systems, Aerosol generators Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nCzas / Time UL2775 (2022) p. 49, 50, 51, 52 Aerosolowe systemy przeciwpozarowe, Generatory aerosolu / Fixed aerosol firefighting systems, Aerosol generators Skutecznosc gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStezenie (O2) / Concentration (O2)\nCzas / Time UL2775 (2022) p. 49, 50, 51, 52","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents UL2775 (2022) p. 49, 50, 51, 52"},{"_id":"6a8324b8884ede9a1b2c4f75","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist","methodology":"Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression","parameters":[{"name":"Temperatura / Temperature"},{"name":"Stężenie (O2) / Concentration (O2)"},{"name":"Stężenie (CO) / Concentration (CO)"},{"name":"Stężenie (CO2) / Concentration (CO2)"},{"name":"Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)"},{"name":"Ciśnienie / Pressure"},{"name":"Czas / Time"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nStężenie (CO) / Concentration (CO)\nStężenie (CO2) / Concentration (CO2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time","reference":"ARGE Guideline - Part 2:2018 Rev. 4.1 p. 3.2, 3.3","norm_bases":["ARGE Guideline - Part 2:2018 Rev. 4.1 p. 3.2, 3.3"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist Skuteczność gaszenia i tłumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nStężenie (CO) / Concentration (CO)\nStężenie (CO2) / Concentration (CO2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time ARGE Guideline - Part 2:2018 Rev. 4.1 p. 3.2, 3.3 Stale wodne systemy przeciwpozarowe - mgla wodna / Fixed water-based firefighting systems - water mist Skutecznosc gaszenia i tlumienia ognia / Effectiveness of fire extinguishment and suppression\nZakres:\nTemperatura / Temperature\nStezenie (O2) / Concentration (O2)\nStezenie (CO) / Concentration (CO)\nStezenie (CO2) / Concentration (CO2)\nObjetosciowe natezenie przeplywu (metoda bezposrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCisnienie / Pressure\nCzas / Time ARGE Guideline - Part 2:2018 Rev. 4.1 p. 3.2, 3.3","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents ARGE Guideline - Part 2:2018 Rev. 4.1 p. 3.2, 3.3"},{"_id":"6a8324b8884ede9a1b2c4f76","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist","methodology":"Skuteczność tłumienia ognia / Effectiveness of fire suppression","parameters":[{"name":"Temperatura / Temperature"},{"name":"Stężenie tlenu Stężenie (O2) / Concentration (O2)"},{"name":"Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)"},{"name":"Ciśnienie / Pressure"},{"name":"Czas / Time"},{"name":"Stopień uszkodzenia, % / Degree of damage, %"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność tłumienia ognia / Effectiveness of fire suppression\nZakres:\nTemperatura / Temperature\nStężenie tlenu Stężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time\nStopień uszkodzenia, % / Degree of damage, %","reference":"Procedura badawcza BFL TP-02 ver. 4 z 13.08.2021 / BFL TP-02 test procedure ver.4 of 13.08.2021 | PN-EN 14972-1:2021, Annex A","norm_bases":["Procedura badawcza BFL TP-02 ver. 4 z 13.08.2021 / BFL TP-02 test procedure ver.4 of 13.08.2021","PN-EN 14972-1:2021, Annex A"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist Skuteczność tłumienia ognia / Effectiveness of fire suppression\nZakres:\nTemperatura / Temperature\nStężenie tlenu Stężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time\nStopień uszkodzenia, % / Degree of damage, % Procedura badawcza BFL TP-02 ver. 4 z 13.08.2021 / BFL TP-02 test procedure ver.4 of 13.08.2021 | PN-EN 14972-1:2021, Annex A Stale wodne systemy przeciwpozarowe - mgla wodna / Fixed water-based firefighting systems - water mist Skutecznosc tlumienia ognia / Effectiveness of fire suppression\nZakres:\nTemperatura / Temperature\nStezenie tlenu Stezenie (O2) / Concentration (O2)\nObjetosciowe natezenie przeplywu (metoda bezposrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCisnienie / Pressure\nCzas / Time\nStopien uszkodzenia, % / Degree of damage, % Procedura badawcza BFL TP-02 ver. 4 z 13.08.2021 / BFL TP-02 test procedure ver.4 of 13.08.2021 | PN-EN 14972-1:2021, Annex A","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents Procedura badawcza BFL TP-02 ver. 4 z 13.08.2021 / BFL TP-02 test procedure ver.4 of 13.08.2021 | PN-EN 14972-1:2021, Annex A"},{"_id":"6a8324b8884ede9a1b2c4f77","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Gazowe systemy przeciwpożarowe - czyste środki gaśnicze / Fixed gas extinguishing firefighting systems - clean extinguishing agent","methodology":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment","parameters":[{"name":"Temperatura / Temperature"},{"name":"Stężenie (O2) / Concentration (O2)"},{"name":"Stężenie (CO) / Concentration (CO)"},{"name":"Stężenie (CO2) / Concentration (CO2)"},{"name":"Ciśnienie (Pa) / Pressure (Pa)"},{"name":"Pomiar masy / Mass measurement"},{"name":"Czas / Time"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nStężenie (CO) / Concentration (CO)\nStężenie (CO2) / Concentration (CO2)\nCiśnienie (Pa) / Pressure (Pa)\nPomiar masy / Mass measurement\nCzas / Time","reference":"NCC71 - 1.1.2021 Chapter 2","norm_bases":["NCC71 - 1.1.2021 Chapter 2"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazowe systemy przeciwpożarowe - czyste środki gaśnicze / Fixed gas extinguishing firefighting systems - clean extinguishing agent Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nStężenie (CO) / Concentration (CO)\nStężenie (CO2) / Concentration (CO2)\nCiśnienie (Pa) / Pressure (Pa)\nPomiar masy / Mass measurement\nCzas / Time NCC71 - 1.1.2021 Chapter 2 Gazowe systemy przeciwpozarowe - czyste srodki gasnicze / Fixed gas extinguishing firefighting systems - clean extinguishing agent Skutecznosc gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStezenie (O2) / Concentration (O2)\nStezenie (CO) / Concentration (CO)\nStezenie (CO2) / Concentration (CO2)\nCisnienie (Pa) / Pressure (Pa)\nPomiar masy / Mass measurement\nCzas / Time NCC71 - 1.1.2021 Chapter 2","categories":["other"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents NCC71 - 1.1.2021 Chapter 2"},{"_id":"6a8324b8884ede9a1b2c4f78","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Gazowe systemy przeciwpożarowe - czyste środki gaśnicze / Fixed gas extinguishing firefighting systems - clean extinguishing agent","methodology":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment","parameters":[{"name":"Temperatura / Temperature"},{"name":"Stężenie (O2) / Concentration (O2)"},{"name":"Ciśnienie (Pa) / Pressure (Pa)"},{"name":"Pomiar masy / Mass measurement"},{"name":"Czas / Time"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nCiśnienie (Pa) / Pressure (Pa)\nPomiar masy / Mass measurement\nCzas / Time","reference":"ISO 14520-1:2023 Annex C | UL2166 (2021) p. 35, 36 ,37 | FM Approval Standard Class 5600:2023 Chapter 4.1","norm_bases":["ISO 14520-1:2023 Annex C","UL2166 (2021) p. 35, 36 ,37","FM Approval Standard Class 5600:2023 Chapter 4.1"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazowe systemy przeciwpożarowe - czyste środki gaśnicze / Fixed gas extinguishing firefighting systems - clean extinguishing agent Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nCiśnienie (Pa) / Pressure (Pa)\nPomiar masy / Mass measurement\nCzas / Time ISO 14520-1:2023 Annex C | UL2166 (2021) p. 35, 36 ,37 | FM Approval Standard Class 5600:2023 Chapter 4.1 Gazowe systemy przeciwpozarowe - czyste srodki gasnicze / Fixed gas extinguishing firefighting systems - clean extinguishing agent Skutecznosc gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStezenie (O2) / Concentration (O2)\nCisnienie (Pa) / Pressure (Pa)\nPomiar masy / Mass measurement\nCzas / Time ISO 14520-1:2023 Annex C | UL2166 (2021) p. 35, 36 ,37 | FM Approval Standard Class 5600:2023 Chapter 4.1","categories":["other"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents ISO 14520-1:2023 Annex C | UL2166 (2021) p. 35, 36 ,37 | FM Approval Standard Class 5600:2023 Chapter 4.1"},{"_id":"6a8324b8884ede9a1b2c4f79","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Pianowe systemy przeciwpożarowe, Koncentraty pianowe / Foam fire protection systems, Foam concentrates","methodology":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment","parameters":[{"name":"Temperatura / Temperature"},{"name":"Czas / Time"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nCzas / Time","reference":"MSC.1/Circ.1312 p. 3.9 | UL 162 (2021) p. 11, 12 | FM Approval Standard Class 5130:2021 chapter 4.2, 4.3, 4.7","norm_bases":["MSC.1/Circ.1312 p. 3.9","UL 162 (2021) p. 11, 12","FM Approval Standard Class 5130:2021 chapter 4.2, 4.3, 4.7"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pianowe systemy przeciwpożarowe, Koncentraty pianowe / Foam fire protection systems, Foam concentrates Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nCzas / Time MSC.1/Circ.1312 p. 3.9 | UL 162 (2021) p. 11, 12 | FM Approval Standard Class 5130:2021 chapter 4.2, 4.3, 4.7 Pianowe systemy przeciwpozarowe, Koncentraty pianowe / Foam fire protection systems, Foam concentrates Skutecznosc gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nCzas / Time MSC.1/Circ.1312 p. 3.9 | UL 162 (2021) p. 11, 12 | FM Approval Standard Class 5130:2021 chapter 4.2, 4.3, 4.7","categories":["other"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents MSC.1/Circ.1312 p. 3.9 | UL 162 (2021) p. 11, 12 | FM Approval Standard Class 5130:2021 chapter 4.2, 4.3, 4.7"},{"_id":"6a8324b8884ede9a1b2c4f7a","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Pianowe systemy przeciwpożarowe, Koncentraty pianowe / Foam fire protection systems, Foam concentrates","methodology":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment","parameters":[{"name":"Temperatura / Temperature"},{"name":"Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)"},{"name":"Ciśnienie / Pressure"},{"name":"Czas / Time"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time","reference":"IMO MSC.1/Circ 1271 Appendix 2","norm_bases":["IMO MSC.1/Circ 1271 Appendix 2"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pianowe systemy przeciwpożarowe, Koncentraty pianowe / Foam fire protection systems, Foam concentrates Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time IMO MSC.1/Circ 1271 Appendix 2 Pianowe systemy przeciwpozarowe, Koncentraty pianowe / Foam fire protection systems, Foam concentrates Skutecznosc gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nObjetosciowe natezenie przeplywu (metoda bezposrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCisnienie / Pressure\nCzas / Time IMO MSC.1/Circ 1271 Appendix 2","categories":["other"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents IMO MSC.1/Circ 1271 Appendix 2"},{"_id":"6a8324b8884ede9a1b2c4f7b","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Pianowe systemy przeciwpożarowe, Koncentraty pianowe / Foam fire protection systems, Foam concentrates","methodology":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment","parameters":[{"name":"Temperatura / Temperature"},{"name":"Czas / Time"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nCzas / Time","reference":"EN 1568-1:2018 Appendix G | EN 1568-1:2018 Appendix H | EN 1568-2:2018 Appendix G | EN 1568-2:2018 Appendix H | EN 1568-3:2018 Appendix G | EN 1568-3:2018 Appendix H | EN 1568-4:2018 Appendix G | EN 1568-4:2018 Appendix H","norm_bases":["EN 1568-1:2018 Appendix G","EN 1568-1:2018 Appendix H","EN 1568-2:2018 Appendix G","EN 1568-2:2018 Appendix H","EN 1568-3:2018 Appendix G","EN 1568-3:2018 Appendix H","EN 1568-4:2018 Appendix G","EN 1568-4:2018 Appendix H"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pianowe systemy przeciwpożarowe, Koncentraty pianowe / Foam fire protection systems, Foam concentrates Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nCzas / Time EN 1568-1:2018 Appendix G | EN 1568-1:2018 Appendix H | EN 1568-2:2018 Appendix G | EN 1568-2:2018 Appendix H | EN 1568-3:2018 Appendix G | EN 1568-3:2018 Appendix H | EN 1568-4:2018 Appendix G | EN 1568-4:2018 Appendix H Pianowe systemy przeciwpozarowe, Koncentraty pianowe / Foam fire protection systems, Foam concentrates Skutecznosc gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nCzas / Time EN 1568-1:2018 Appendix G | EN 1568-1:2018 Appendix H | EN 1568-2:2018 Appendix G | EN 1568-2:2018 Appendix H | EN 1568-3:2018 Appendix G | EN 1568-3:2018 Appendix H | EN 1568-4:2018 Appendix G | EN 1568-4:2018 Appendix H","categories":["other"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents EN 1568-1:2018 Appendix G | EN 1568-1:2018 Appendix H | EN 1568-2:2018 Appendix G | EN 1568-2:2018 Appendix H | EN 1568-3:2018 Appendix G | EN 1568-3:2018 Appendix H | EN 1568-4:2018 Appendix G | EN 1568-4:2018 Appendix H"},{"_id":"6a8324b8884ede9a1b2c4f7c","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist","methodology":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment","parameters":[{"name":"Temperatura / Temperature"},{"name":"Stężenie (O2) / Concentration (O2)"},{"name":"Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)"},{"name":"Ciśnienie / Pressure"},{"name":"Czas / Time"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time","reference":"EN 14972-12:2023","norm_bases":["EN 14972-12:2023"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time EN 14972-12:2023 Stale wodne systemy przeciwpozarowe - mgla wodna / Fixed water-based firefighting systems - water mist Skutecznosc gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStezenie (O2) / Concentration (O2)\nObjetosciowe natezenie przeplywu (metoda bezposrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCisnienie / Pressure\nCzas / Time EN 14972-12:2023","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents EN 14972-12:2023"},{"_id":"6a8324b8884ede9a1b2c4f7d","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist","methodology":"Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)","parameters":[{"name":"Temperatura / Temperature"},{"name":"Ciśnienie / Pressure"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nZakres:\nTemperatura / Temperature\nCiśnienie / Pressure","reference":"IMO MSC/Circ.1165 p. 4.10","norm_bases":["IMO MSC/Circ.1165 p. 4.10"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nZakres:\nTemperatura / Temperature\nCiśnienie / Pressure IMO MSC/Circ.1165 p. 4.10 Stale wodne systemy przeciwpozarowe - mgla wodna / Fixed water-based firefighting systems - water mist Objetosciowe natezenie przeplywu (metoda bezposrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nZakres:\nTemperatura / Temperature\nCisnienie / Pressure IMO MSC/Circ.1165 p. 4.10","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents IMO MSC/Circ.1165 p. 4.10"},{"_id":"6a8324b8884ede9a1b2c4f7e","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist","methodology":"Objętościowe natężenie przepływu / Volumetric flow rate","parameters":[{"name":"Ciśnienie / Pressure"},{"name":"Pole powierzchni / Surface area"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Objętościowe natężenie przepływu / Volumetric flow rate\nZakres:\nCiśnienie / Pressure\nPole powierzchni / Surface area","reference":"PN-EN 17450-1","norm_bases":["PN-EN 17450-1"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist Objętościowe natężenie przepływu / Volumetric flow rate\nZakres:\nCiśnienie / Pressure\nPole powierzchni / Surface area PN-EN 17450-1 Stale wodne systemy przeciwpozarowe - mgla wodna / Fixed water-based firefighting systems - water mist Objetosciowe natezenie przeplywu / Volumetric flow rate\nZakres:\nCisnienie / Pressure\nPole powierzchni / Surface area PN-EN 17450-1","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents PN-EN 17450-1"},{"_id":"6a8324b8884ede9a1b2c4f7f","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist","methodology":"Funkcjonalność dyszy / Nozzle functionality","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Funkcjonalność dyszy / Nozzle functionality","reference":"PN-EN 17450-2 Annex A | PN-EN 17450-2 Annex B | PN-EN 17450-2 Annex C.1 | PN-EN 17450-2 Annex C.4","norm_bases":["PN-EN 17450-2 Annex A","PN-EN 17450-2 Annex B","PN-EN 17450-2 Annex C.1","PN-EN 17450-2 Annex C.4"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist Funkcjonalność dyszy / Nozzle functionality PN-EN 17450-2 Annex A | PN-EN 17450-2 Annex B | PN-EN 17450-2 Annex C.1 | PN-EN 17450-2 Annex C.4 Stale wodne systemy przeciwpozarowe - mgla wodna / Fixed water-based firefighting systems - water mist Funkcjonalnosc dyszy / Nozzle functionality PN-EN 17450-2 Annex A | PN-EN 17450-2 Annex B | PN-EN 17450-2 Annex C.1 | PN-EN 17450-2 Annex C.4","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents PN-EN 17450-2 Annex A | PN-EN 17450-2 Annex B | PN-EN 17450-2 Annex C.1 | PN-EN 17450-2 Annex C.4"},{"_id":"6a8324b8884ede9a1b2c4f80","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist","methodology":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment","parameters":[{"name":"Temperatura / Temperature"},{"name":"Stężenie (O2) / Concentration (O2)"},{"name":"Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)"},{"name":"Ciśnienie / Pressure"},{"name":"Czas / Time"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time","reference":"PN-EN 14972-16","norm_bases":["PN-EN 14972-16"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time PN-EN 14972-16 Stale wodne systemy przeciwpozarowe - mgla wodna / Fixed water-based firefighting systems - water mist Skutecznosc gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStezenie (O2) / Concentration (O2)\nObjetosciowe natezenie przeplywu (metoda bezposrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCisnienie / Pressure\nCzas / Time PN-EN 14972-16","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents PN-EN 14972-16"},{"_id":"6a8324b8884ede9a1b2c4f81","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist","methodology":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment","parameters":[{"name":"Temperatura / Temperature"},{"name":"Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)"},{"name":"Ciśnienie / Pressure"},{"name":"Czas / Time"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time","reference":"ISO 15371:2015 | PN-EN 17446:2021","norm_bases":["ISO 15371:2015","PN-EN 17446:2021"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time ISO 15371:2015 | PN-EN 17446:2021 Stale wodne systemy przeciwpozarowe - mgla wodna / Fixed water-based firefighting systems - water mist Skutecznosc gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nObjetosciowe natezenie przeplywu (metoda bezposrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCisnienie / Pressure\nCzas / Time ISO 15371:2015 | PN-EN 17446:2021","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents ISO 15371:2015 | PN-EN 17446:2021"},{"_id":"6a8324b8884ede9a1b2c4f82","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist","methodology":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment","parameters":[{"name":"Temperatura / Temperature"},{"name":"Stężenie (O2) / Concentration (O2)"},{"name":"Stężenie (CO) / Concentration (CO)"},{"name":"Stężenie (CO2) / Concentration (CO2)"},{"name":"Objętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)"},{"name":"Ciśnienie / Pressure"},{"name":"Czas / Time"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nStężenie (CO) / Concentration (CO)\nStężenie (CO2) / Concentration (CO2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time","reference":"FM Approval Standard Class 5560:2021 Appendix A | FM Approval Standard Class 5560:2021 Appendix B | FM Approval Standard Class 5560:2021 Appendix C | FM Approval Standard Class 5560:2021 Appendix D | FM Approval Standard Class 5560:2021 Appendix I | JH-C077-E-RP-001","norm_bases":["FM Approval Standard Class 5560:2021 Appendix A","FM Approval Standard Class 5560:2021 Appendix B","FM Approval Standard Class 5560:2021 Appendix C","FM Approval Standard Class 5560:2021 Appendix D","FM Approval Standard Class 5560:2021 Appendix I","JH-C077-E-RP-001"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stałe wodne systemy przeciwpożarowe - mgła wodna / Fixed water-based firefighting systems - water mist Skuteczność gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStężenie (O2) / Concentration (O2)\nStężenie (CO) / Concentration (CO)\nStężenie (CO2) / Concentration (CO2)\nObjętościowe natężenie przepływu (metoda bezpośrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCiśnienie / Pressure\nCzas / Time FM Approval Standard Class 5560:2021 Appendix A | FM Approval Standard Class 5560:2021 Appendix B | FM Approval Standard Class 5560:2021 Appendix C | FM Approval Standard Class 5560:2021 Appendix D | FM Approval Standard Class 5560:2021 Appendix I | JH-C077-E-RP-001 Stale wodne systemy przeciwpozarowe - mgla wodna / Fixed water-based firefighting systems - water mist Skutecznosc gaszenia ognia / Effectiveness of fire extinguishment\nZakres:\nTemperatura / Temperature\nStezenie (O2) / Concentration (O2)\nStezenie (CO) / Concentration (CO)\nStezenie (CO2) / Concentration (CO2)\nObjetosciowe natezenie przeplywu (metoda bezposrednia, metoda wagowa) / Volumetric flow rate (direct method, weight method)\nCisnienie / Pressure\nCzas / Time FM Approval Standard Class 5560:2021 Appendix A | FM Approval Standard Class 5560:2021 Appendix B | FM Approval Standard Class 5560:2021 Appendix C | FM Approval Standard Class 5560:2021 Appendix D | FM Approval Standard Class 5560:2021 Appendix I | JH-C077-E-RP-001","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents FM Approval Standard Class 5560:2021 Appendix A | FM Approval Standard Class 5560:2021 Appendix B | FM Approval Standard Class 5560:2021 Appendix C | FM Approval Standard Class 5560:2021 Appendix D | FM Approval Standard Class 5560:2021 Appendix I | JH-C077-E-RP-001"},{"_id":"6a8324b8884ede9a1b2c4f83","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Gaśnice przenośne / Portable fire extinguishers","methodology":"Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy A / Minimum extinguishing efficiency – class A fire rating","parameters":[{"name":"Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy B / Minimum extinguishing efficiency – class B fire rating"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy A / Minimum extinguishing efficiency – class A fire rating\nMinimalna skuteczność gaśnicza – ocena pożaru testowego grupy B / Minimum extinguishing efficiency – class B fire rating","reference":"PN-EN 3-7:2008 (Appendix I)","norm_bases":["PN-EN 3-7:2008 (Appendix I)"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przenośne / Portable fire extinguishers Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy A / Minimum extinguishing efficiency – class A fire rating\nMinimalna skuteczność gaśnicza – ocena pożaru testowego grupy B / Minimum extinguishing efficiency – class B fire rating PN-EN 3-7:2008 (Appendix I) Gasnice przenosne / Portable fire extinguishers Minimalna skutecznosc gasnicza – ocena pozaru testowego grupy A / Minimum extinguishing efficiency – class A fire rating\nMinimalna skutecznosc gasnicza – ocena pozaru testowego grupy B / Minimum extinguishing efficiency – class B fire rating PN-EN 3-7:2008 (Appendix I)","categories":["other"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"methodology_en":"Minimum extinguishing efficiency – class A fire rating","parameters_en":[{"name":"Minimum extinguishing efficiency – class B fire rating"}],"search_en":"Portable fire extinguishers Minimum extinguishing efficiency – class A fire rating Minimum extinguishing efficiency – class B fire rating Type of activity/ parameter/ characteristic tested Reference documents PN-EN 3-7:2008 (Appendix I)","test_object_en":"Portable fire extinguishers","search_zh":"手提式灭火器 PN-EN 3-7:2008 (Appendix I)","test_object_zh":"手提式灭火器"},{"_id":"6a8324b8884ede9a1b2c4f84","lab_id":"69ad52a3de79e566650fb98d","country":"PL","accr_number":"AB 1792","accr_body":"PCA","test_object":"Gaśnice przewoźne / Mobile fire extinguishers","methodology":"Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy A / Minimum extinguishing efficiency – class A fire rating","parameters":[{"name":"Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy B / Minimum extinguishing efficiency – class B fire rating"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Materiał/product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy A / Minimum extinguishing efficiency – class A fire rating\nMinimalna skuteczność gaśnicza – ocena pożaru testowego grupy B / Minimum extinguishing efficiency – class B fire rating","reference":"PN-EN 1866-1:2010 (chapter 8)","norm_bases":["PN-EN 1866-1:2010 (chapter 8)"],"lab_section":"BFL Fire Testing Laboratory","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gaśnice przewoźne / Mobile fire extinguishers Minimalna skuteczność gaśnicza – ocena pożaru testowego grupy A / Minimum extinguishing efficiency – class A fire rating\nMinimalna skuteczność gaśnicza – ocena pożaru testowego grupy B / Minimum extinguishing efficiency – class B fire rating PN-EN 1866-1:2010 (chapter 8) Gasnice przewozne / Mobile fire extinguishers Minimalna skutecznosc gasnicza – ocena pozaru testowego grupy A / Minimum extinguishing efficiency – class A fire rating\nMinimalna skutecznosc gasnicza – ocena pozaru testowego grupy B / Minimum extinguishing efficiency – class B fire rating PN-EN 1866-1:2010 (chapter 8)","categories":["other"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Materiał/product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"methodology_en":"Minimum extinguishing efficiency – class A fire rating","parameters_en":[{"name":"Minimum extinguishing efficiency – class B fire rating"}],"search_en":"Minimum extinguishing efficiency – class A fire rating Minimum extinguishing efficiency – class B fire rating Type of activity/ parameter/ characteristic tested Reference documents PN-EN 1866-1:2010 (chapter 8)"}],"has_pdf":true}