{"lab":{"_id":"69ad52a3de79e566650fb97f","country":"PL","accr_number":"AB 1785","accr_body":"PCA","address":"„LECH” Sp. z o.o., ul. Kombatantów 4, 15-110 Białystok, ZAKŁAD UNIESZKODLIWIANIA ODPADÓW KOMUNALNYCH, ul. Gen. Wł. Andersa 40F","categories":["environment"],"city":"Białystok","imported_at":"2026-03-08T10:42:43.265Z","methods_count":11,"name":"PRZEDSIĘBIORSTWO USŁUGOWO-HANDLOWO-PRODUKCYJNE","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1785.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo usługowo-handlowo-produkcyjne „lech” sp. z o.o., ul. kombatantów 4, 15-110 białystok, zakład unieszkodliwiania odpadów komunalnych, ul. gen. wł. andersa 40f environment other","status":"active","updated_at":"2026-03-08T14:50:55.095Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:55.095Z","location":{"type":"Point","coordinates":[23.1688,53.1325]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201785,podmiot.html","fields_of_testing":[{"codes":"C/32/P","pl":"Badania chemiczne i pobieranie próbek odpadów","en":"Chemical tests and sampling of waste"},{"codes":"N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek odpadów","en":"Tests of physical properties and sampling of waste"}],"issue":{"no":"4","date":"06.03.2025"},"parse_date":"2026-07-20T07:09:29.462Z","parse_source":"script-pdfplumber","map_coord":[53.150762,23.159725],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":11},"category_scores":{"environment":11},"has_zh":true},"methods":[{"_id":"6a5dc9a9f1c10c8ce8259f4c","lab_id":"69ad52a3de79e566650fb97f","country":"PL","accr_number":"AB 1785","accr_body":"PCA","test_object":"Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99","test_object_en":"Waste code: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 21645:2021-09","norm_bases":["PN-EN ISO 21645:2021-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 21645:2021-09 Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 21645:2021-09","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Sampling for chemical and physical testing PN-EN ISO 21645:2021-09","methodology_zh":"化学与物理检测用样品采集","search_zh":"废物，代码：19 12 08、19 12 10、19 12 12、20 01 11、20 03 01、20 03 02、20 03 07、20 03 99 化学与物理检测用样品采集 PN-EN ISO 21645:2021-09","test_object_zh":"废物，代码：19 12 08、19 12 10、19 12 12、20 01 11、20 03 01、20 03 02、20 03 07、20 03 99"},{"_id":"6a5dc9a9f1c10c8ce8259f4d","lab_id":"69ad52a3de79e566650fb97f","country":"PL","accr_number":"AB 1785","accr_body":"PCA","test_object":"Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99","test_object_en":"Waste code: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(1,0 – 70,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 70,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (1,0 – 70,0) %\nMetoda wagowa","reference":"CEN/TS 15414-1:2010","norm_bases":["CEN/TS 15414-1:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Zawartość wilgoci całkowitej\nZakres (1,0 – 70,0) %\nMetoda wagowa CEN/TS 15414-1:2010 Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Zawartosc wilgoci calkowitej\nZakres (1,0 – 70,0) %\nMetoda wagowa CEN/TS 15414-1:2010","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Total moisture content Gravimetric method Range CEN/TS 15414-1:2010","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 70,0) %"}],"search_zh":"废物，代码：19 12 08、19 12 10、19 12 12、20 01 11、20 03 01、20 03 02、20 03 07、20 03 99 全水分含量 重量法 范围 CEN/TS 15414-1:2010","technique_zh":"重量法","test_object_zh":"废物，代码：19 12 08、19 12 10、19 12 12、20 01 11、20 03 01、20 03 02、20 03 07、20 03 99"},{"_id":"6a5dc9a9f1c10c8ce8259f4e","lab_id":"69ad52a3de79e566650fb97f","country":"PL","accr_number":"AB 1785","accr_body":"PCA","test_object":"Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99","test_object_en":"Waste code: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99","methodology":"Zawartość wilgoci w próbce analitycznej","methodology_en":"Moisture content in the analytical sample","parameters":[{"name":"Zakres","range":"(1,0 – 40,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 40,0) %\nMetoda wagowa","reference":"PN-EN ISO 21660-3:2021-08","norm_bases":["PN-EN ISO 21660-3:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 40,0) %\nMetoda wagowa PN-EN ISO 21660-3:2021-08 Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Zawartosc wilgoci w probce analitycznej\nZakres (1,0 – 40,0) %\nMetoda wagowa PN-EN ISO 21660-3:2021-08","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Moisture content in the analytical sample Gravimetric method Range PN-EN ISO 21660-3:2021-08","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 40,0) %"}],"search_zh":"废物，代码：19 12 08、19 12 10、19 12 12、20 01 11、20 03 01、20 03 02、20 03 07、20 03 99 分析样品水分含量 重量法 范围 PN-EN ISO 21660-3:2021-08","technique_zh":"重量法","test_object_zh":"废物，代码：19 12 08、19 12 10、19 12 12、20 01 11、20 03 01、20 03 02、20 03 07、20 03 99"},{"_id":"6a5dc9a9f1c10c8ce8259f4f","lab_id":"69ad52a3de79e566650fb97f","country":"PL","accr_number":"AB 1785","accr_body":"PCA","test_object":"Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99","test_object_en":"Waste code: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(1,0 – 70,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 70,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (1,0 – 70,0) %\nMetoda wagowa","reference":"PN-EN ISO 21656:2021-08","norm_bases":["PN-EN ISO 21656:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Zawartość popiołu\nZakres (1,0 – 70,0) %\nMetoda wagowa PN-EN ISO 21656:2021-08 Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Zawartosc popiolu\nZakres (1,0 – 70,0) %\nMetoda wagowa PN-EN ISO 21656:2021-08","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Ash content Gravimetric method Range PN-EN ISO 21656:2021-08","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 70,0) %"}],"search_zh":"废物，代码：19 12 08、19 12 10、19 12 12、20 01 11、20 03 01、20 03 02、20 03 07、20 03 99 灰分含量 重量法 范围 PN-EN ISO 21656:2021-08","technique_zh":"重量法","test_object_zh":"废物，代码：19 12 08、19 12 10、19 12 12、20 01 11、20 03 01、20 03 02、20 03 07、20 03 99"},{"_id":"6a5dc9a9f1c10c8ce8259f50","lab_id":"69ad52a3de79e566650fb97f","country":"PL","accr_number":"AB 1785","accr_body":"PCA","test_object":"Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99","test_object_en":"Waste code: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(4,00 – 80,0) %"}],"parameters_en":[{"name":"Range","range":"(4,00 – 80,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres (4,00 – 80,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Zawartość węgla całkowitego\nZakres (4,00 – 80,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 21663:2021-06 Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Zawartosc wegla calkowitego\nZakres (4,00 – 80,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 21663:2021-06","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Total carbon content High-temperature combustion with IR detection Range PN-EN ISO 21663:2021-06","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(4,00 – 80,0) %"}],"search_zh":"废物，代码：19 12 08、19 12 10、19 12 12、20 01 11、20 03 01、20 03 02、20 03 07、20 03 99 总碳含量 高温燃烧红外检测法 范围 PN-EN ISO 21663:2021-06","technique_zh":"高温燃烧红外检测法","test_object_zh":"废物，代码：19 12 08、19 12 10、19 12 12、20 01 11、20 03 01、20 03 02、20 03 07、20 03 99"},{"_id":"6a5dc9a9f1c10c8ce8259f51","lab_id":"69ad52a3de79e566650fb97f","country":"PL","accr_number":"AB 1785","accr_body":"PCA","test_object":"Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99","test_object_en":"Waste code: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99","methodology":"Zawartość wodoru","methodology_en":"Hydrogen content","parameters":[{"name":"Zakres","range":"(1,70 – 14,0) %"}],"parameters_en":[{"name":"Range","range":"(1,70 – 14,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość wodoru\nZakres (1,70 – 14,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Zawartość wodoru\nZakres (1,70 – 14,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 21663:2021-06 Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Zawartosc wodoru\nZakres (1,70 – 14,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 21663:2021-06","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Hydrogen content High-temperature combustion with IR detection Range PN-EN ISO 21663:2021-06","parameters_zh":[{"name":"范围","range":"(1,70 – 14,0) %"}],"search_zh":"废物，代码：19 12 08、19 12 10、19 12 12、20 01 11、20 03 01、20 03 02、20 03 07、20 03 99 氢含量 高温燃烧红外检测法 范围 PN-EN ISO 21663:2021-06","technique_zh":"高温燃烧红外检测法","methodology_zh":"氢含量","test_object_zh":"废物，代码：19 12 08、19 12 10、19 12 12、20 01 11、20 03 01、20 03 02、20 03 07、20 03 99"},{"_id":"6a5dc9a9f1c10c8ce8259f52","lab_id":"69ad52a3de79e566650fb97f","country":"PL","accr_number":"AB 1785","accr_body":"PCA","test_object":"Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99","test_object_en":"Waste code: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99","methodology":"Zawartość siarki całkowitej","methodology_en":"Total sulfur content","parameters":[{"name":"Zakres","range":"(0,20 – 2,20) %"}],"parameters_en":[{"name":"Range","range":"(0,20 – 2,20) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej\nZakres (0,20 – 2,20) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Zawartość siarki całkowitej\nZakres (0,20 – 2,20) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 21663:2021-06 Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Zawartosc siarki calkowitej\nZakres (0,20 – 2,20) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 21663:2021-06","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Total sulfur content High-temperature combustion with IR detection Range PN-EN ISO 21663:2021-06","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,20 – 2,20) %"}],"search_zh":"废物，代码：19 12 08、19 12 10、19 12 12、20 01 11、20 03 01、20 03 02、20 03 07、20 03 99 全硫含量 高温燃烧红外检测法 范围 PN-EN ISO 21663:2021-06","technique_zh":"高温燃烧红外检测法","test_object_zh":"废物，代码：19 12 08、19 12 10、19 12 12、20 01 11、20 03 01、20 03 02、20 03 07、20 03 99"},{"_id":"6a5dc9a9f1c10c8ce8259f53","lab_id":"69ad52a3de79e566650fb97f","country":"PL","accr_number":"AB 1785","accr_body":"PCA","test_object":"Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99","test_object_en":"Waste code: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99","methodology":"Ciepło spalania","methodology_en":"Gross calorific value","parameters":[{"name":"Zakres","range":"(3600 – 35 000) J/g"}],"parameters_en":[{"name":"Range","range":"(3600 – 35 000) J/g"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"technique_en":"Calorimetric method","computed":[],"computed_en":[],"activity":"Ciepło spalania\nZakres (3600 – 35 000) J/g\nMetoda kalorymetryczna","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Ciepło spalania\nZakres (3600 – 35 000) J/g\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12 Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Cieplo spalania\nZakres (3600 – 35 000) J/g\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Gross calorific value Calorimetric method Range PN-EN ISO 21654:2021-12","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(3600 – 35 000) J/g"}],"search_zh":"废物，代码：19 12 08、19 12 10、19 12 12、20 01 11、20 03 01、20 03 02、20 03 07、20 03 99 高位发热量 量热法 范围 PN-EN ISO 21654:2021-12","technique_zh":"量热法","test_object_zh":"废物，代码：19 12 08、19 12 10、19 12 12、20 01 11、20 03 01、20 03 02、20 03 07、20 03 99"},{"_id":"6a5dc9a9f1c10c8ce8259f54","lab_id":"69ad52a3de79e566650fb97f","country":"PL","accr_number":"AB 1785","accr_body":"PCA","test_object":"Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99","test_object_en":"Waste code: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99","methodology":"Wartość opałowa (z obliczeń)","methodology_en":"Net calorific value (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Wartość opałowa (z obliczeń) PN-EN ISO 21654:2021-12 Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Wartosc opalowa (z obliczen) PN-EN ISO 21654:2021-12","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Net calorific value (calculated) PN-EN ISO 21654:2021-12","methodology_zh":"低位发热量（计算值）","search_zh":"废物，代码：19 12 08、19 12 10、19 12 12、20 01 11、20 03 01、20 03 02、20 03 07、20 03 99 低位发热量（计算值） PN-EN ISO 21654:2021-12","test_object_zh":"废物，代码：19 12 08、19 12 10、19 12 12、20 01 11、20 03 01、20 03 02、20 03 07、20 03 99"},{"_id":"6a5dc9a9f1c10c8ce8259f55","lab_id":"69ad52a3de79e566650fb97f","country":"PL","accr_number":"AB 1785","accr_body":"PCA","test_object":"Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99","test_object_en":"Waste code: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99","methodology":"Zawartość wilgoci w próbce analitycznej","methodology_en":"Moisture content in the analytical sample","parameters":[{"name":"Zakres","range":"(1,0 – 20,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 20,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 20,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 21660-3:2021-08","norm_bases":["PN-EN ISO 21660-3:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 20,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 21660-3:2021-08 Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Zawartosc wilgoci w probce analitycznej\nZakres (1,0 – 20,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 21660-3:2021-08","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Moisture content in the analytical sample Thermogravimetric method (TGA) Range PN-EN ISO 21660-3:2021-08","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 20,0) %"}],"search_zh":"废物，代码：19 12 08、19 12 10、19 12 12、20 01 11、20 03 01、20 03 02、20 03 07、20 03 99 分析样品水分含量 热重法（TGA） 范围 PN-EN ISO 21660-3:2021-08","technique_zh":"热重法（TGA）","test_object_zh":"废物，代码：19 12 08、19 12 10、19 12 12、20 01 11、20 03 01、20 03 02、20 03 07、20 03 99"},{"_id":"6a5dc9a9f1c10c8ce8259f56","lab_id":"69ad52a3de79e566650fb97f","country":"PL","accr_number":"AB 1785","accr_body":"PCA","test_object":"Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99","test_object_en":"Waste code: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(1,0 – 70,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 70,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (1,0 – 70,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 21656:2021-08","norm_bases":["PN-EN ISO 21656:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Zawartość popiołu\nZakres (1,0 – 70,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 21656:2021-08 Odpady kod: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Zawartosc popiolu\nZakres (1,0 – 70,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 21656:2021-08","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 19 12 08, 19 12 10, 19 12 12, 20 01 11, 20 03 01, 20 03 02, 20 03 07, 20 03 99 Ash content Thermogravimetric method (TGA) Range PN-EN ISO 21656:2021-08","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 70,0) %"}],"search_zh":"废物，代码：19 12 08、19 12 10、19 12 12、20 01 11、20 03 01、20 03 02、20 03 07、20 03 99 灰分含量 热重法（TGA） 范围 PN-EN ISO 21656:2021-08","technique_zh":"热重法（TGA）","test_object_zh":"废物，代码：19 12 08、19 12 10、19 12 12、20 01 11、20 03 01、20 03 02、20 03 07、20 03 99"}],"has_pdf":true}