{"lab":{"_id":"69ad52a3de79e566650fb975","country":"PL","accr_number":"AB 1780","accr_body":"PCA","address":"ul. W. Bandrowskiego 16, 33-100 Tarnów, ODDZIAŁ WSPARCIA W WARSZAWIE, ul. Krucza 6/14","categories":["petro","water"],"city":"Tarnów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":18,"name":"POLSKA SPÓŁKA GAZOWNICTWA sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1780.pdf"],"scope_summary":"","search_text":"polska spółka gazownictwa sp. z o.o. ul. w. bandrowskiego 16, 33-100 tarnów, oddział wsparcia w warszawie, ul. krucza 6/14 petro other water metrology","status":"active","updated_at":"2026-03-08T14:50:54.815Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:54.815Z","location":{"type":"Point","coordinates":[20.9858,50.0121]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%201780,podmiot.html","fields_of_testing":[{"codes":"C/10/P","pl":"Badania chemiczne i pobieranie próbek paliw gazowych","en":"Chemical tests and sampling of gas fuels"},{"codes":"N/10/P","pl":"Badanie właściwości fizycznych i pobieranie próbek paliw gazowych","en":"Tests of physical properties and sampling of gas fuels"},{"codes":"M/13","pl":"Badania inne (procesowych chromatografów gazowych, procesowych analizatorów temperatury punktu rosy wody)","en":"Other tests (of process gas chromatographs, of process water dew point temperature analyzers)"}],"issue":{"no":"8","date":"09.01.2026"},"parse_date":"2026-07-20T07:09:29.380Z","parse_source":"script-pdfplumber","map_coord":[50.012378,20.988074],"map_geo":"nominatim-city","has_en":true,"category_counts":{"petro":14,"water":4,"other":2},"category_scores":{"petro":9.8,"water":0.8,"other":0.2},"has_zh":true},"methods":[{"_id":"6a5dc9a9f1c10c8ce8259f2c","lab_id":"69ad52a3de79e566650fb975","country":"PL","accr_number":"AB 1780","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","test_object_en":"Gaseous fuels: natural gas","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"ZLB-Kraków-01 Wydanie 6 z dnia 18.09.2023 r.","norm_bases":["ZLB-Kraków-01 Wydanie 6 z dnia 18.09.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny Pobieranie próbek do badań chemicznych i fizycznych ZLB-Kraków-01 Wydanie 6 z dnia 18.09.2023 r. Paliwa gazowe: gaz ziemny Pobieranie probek do badan chemicznych i fizycznych ZLB-Krakow-01 Wydanie 6 z dnia 18.09.2023 r.","categories":["petro"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gaseous fuels: natural gas Sampling for chemical and physical testing ZLB-Kraków-01 Wydanie 6 z dnia 18.09.2023 r.","methodology_zh":"化学与物理检测用样品采集","search_zh":"气体燃料：天然气 化学与物理检测用样品采集 ZLB-Kraków-01 Wydanie 6 z dnia 18.09.2023 r.","test_object_zh":"气体燃料：天然气"},{"_id":"6a5dc9a9f1c10c8ce8259f2d","lab_id":"69ad52a3de79e566650fb975","country":"PL","accr_number":"AB 1780","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","test_object_en":"Gaseous fuels: natural gas","methodology":"Skład gazu w zakresie podstawowym","methodology_en":"Gas composition in the basic range","parameters":[{"name":"C1","range":"(86,2 – 99,9) % mol"},{"name":"C2","range":"(0,01 – 7,5) % mol"},{"name":"C3","range":"(0,05 – 2,0) % mol"},{"name":"i-C4","range":"(0,005 – 0,4) % mol"},{"name":"n-C4","range":"(0,005 – 0,3) % mol"},{"name":"i-C5","range":"(0,003 – 0,2) % mol"},{"name":"n-C5","range":"(0,003 – 0,1) % mol"},{"name":"neo-C5","range":"(0,001 – 0,02) % mol"},{"name":"n-C6+","range":"(0,001 – 0,15) % mol"},{"name":"N2","range":"(0,15 – 3,5) %"},{"name":"CO2","range":"(0,05 – 1,5) %"},{"name":"O2","range":"(0,003 – 0,2) %"}],"parameters_en":[{"name":"C1","range":"(86,2 – 99,9) % mol"},{"name":"C2","range":"(0,01 – 7,5) % mol"},{"name":"C3","range":"(0,05 – 2,0) % mol"},{"name":"i-C4","range":"(0,005 – 0,4) % mol"},{"name":"n-C4","range":"(0,005 – 0,3) % mol"},{"name":"i-C5","range":"(0,003 – 0,2) % mol"},{"name":"n-C5","range":"(0,003 – 0,1) % mol"},{"name":"neo-C5","range":"(0,001 – 0,02) % mol"},{"name":"n-C6+","range":"(0,001 – 0,15) % mol"},{"name":"N2","range":"(0,15 – 3,5) %"},{"name":"CO2","range":"(0,05 – 1,5) %"},{"name":"O2","range":"(0,003 – 0,2) %"}],"technique":"Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","techniques":["Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)"],"technique_en":"Gas chromatography with thermal conductivity detection (GC-TCD)","computed":[],"computed_en":[],"activity":"Skład gazu w zakresie podstawowym\nZakres:\nC1 (86,2 – 99,9) % mol\nC2 (0,01 – 7,5) % mol\nC3 (0,05 – 2,0) % mol\ni-C4 (0,005 – 0,4) % mol\nn-C4 (0,005 – 0,3) % mol\ni-C5 (0,003 – 0,2) % mol\nn-C5 (0,003 – 0,1) % mol\nneo-C5 (0,001 – 0,02) % mol\nn-C6+ (0,001 – 0,15) % mol\nN2 (0,15 – 3,5) %\nCO2 (0,05 – 1,5) %\nO2 (0,003 – 0,2) %\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","reference":"ZLB-Kraków-02 Wydanie 7 z dnia 18.09.2024 r.","norm_bases":["ZLB-Kraków-02 Wydanie 7 z dnia 18.09.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny Skład gazu w zakresie podstawowym\nZakres:\nC1 (86,2 – 99,9) % mol\nC2 (0,01 – 7,5) % mol\nC3 (0,05 – 2,0) % mol\ni-C4 (0,005 – 0,4) % mol\nn-C4 (0,005 – 0,3) % mol\ni-C5 (0,003 – 0,2) % mol\nn-C5 (0,003 – 0,1) % mol\nneo-C5 (0,001 – 0,02) % mol\nn-C6+ (0,001 – 0,15) % mol\nN2 (0,15 – 3,5) %\nCO2 (0,05 – 1,5) %\nO2 (0,003 – 0,2) %\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) ZLB-Kraków-02 Wydanie 7 z dnia 18.09.2024 r. Paliwa gazowe: gaz ziemny Sklad gazu w zakresie podstawowym\nZakres:\nC1 (86,2 – 99,9) % mol\nC2 (0,01 – 7,5) % mol\nC3 (0,05 – 2,0) % mol\ni-C4 (0,005 – 0,4) % mol\nn-C4 (0,005 – 0,3) % mol\ni-C5 (0,003 – 0,2) % mol\nn-C5 (0,003 – 0,1) % mol\nneo-C5 (0,001 – 0,02) % mol\nn-C6+ (0,001 – 0,15) % mol\nN2 (0,15 – 3,5) %\nCO2 (0,05 – 1,5) %\nO2 (0,003 – 0,2) %\nMetoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) ZLB-Krakow-02 Wydanie 7 z dnia 18.09.2024 r.","categories":["petro"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gaseous fuels: natural gas Gas composition in the basic range Gas chromatography with thermal conductivity detection (GC-TCD) C1 C2 C3 i-C4 n-C4 i-C5 n-C5 neo-C5 n-C6+ N2 CO2 O2 ZLB-Kraków-02 Wydanie 7 z dnia 18.09.2024 r.","parameters_zh":[{"name":"C1","range":"(86,2 – 99,9) % mol"},{"name":"C2","range":"(0,01 – 7,5) % mol"},{"name":"C3","range":"(0,05 – 2,0) % mol"},{"name":"i-C4","range":"(0,005 – 0,4) % mol"},{"name":"n-C4","range":"(0,005 – 0,3) % mol"},{"name":"i-C5","range":"(0,003 – 0,2) % mol"},{"name":"n-C5","range":"(0,003 – 0,1) % mol"},{"name":"新戊烷（neo-C5）","range":"(0,001 – 0,02) % mol"},{"name":"n-C6+","range":"(0,001 – 0,15) % mol"},{"name":"N2","range":"(0,15 – 3,5) %"},{"name":"CO2","range":"(0,05 – 1,5) %"},{"name":"O2","range":"(0,003 – 0,2) %"}],"search_zh":"气体燃料：天然气 基本范围内的气体组成 气相色谱-热导检测法（GC-TCD） 新戊烷（neo-C5） CO2 O2 ZLB-Kraków-02 Wydanie 7 z dnia 18.09.2024 r.","technique_zh":"气相色谱-热导检测法（GC-TCD）","test_object_zh":"气体燃料：天然气","methodology_zh":"基本范围内的气体组成"},{"_id":"6a5dc9a9f1c10c8ce8259f2e","lab_id":"69ad52a3de79e566650fb975","country":"PL","accr_number":"AB 1780","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","test_object_en":"Gaseous fuels: natural gas","methodology":"Skład gazu w zakresie rozszerzonym","methodology_en":"Gas composition in the extended range","parameters":[{"name":"C1","range":"(86,2 – 99,9) % mol"},{"name":"C2","range":"(0,01 – 7,5) % mol"},{"name":"C3","range":"(0,05 – 2,0) % mol"},{"name":"i-C4","range":"(0,005 – 0,4) % mol"},{"name":"n-C4","range":"(0,005 – 0,3) % mol"},{"name":"i-C5","range":"(0,003 – 0,2) % mol"},{"name":"n-C5","range":"(0,003 – 0,1) % mol"},{"name":"neo-C5","range":"(0,001 – 0,02) % mol"},{"name":"n-C6+","range":"(0,001 – 0,15) % mol"},{"name":"N2","range":"(0,15 – 3,5) % mol"},{"name":"CO2","range":"(0,05 – 1,5) % mol"},{"name":"O2","range":"(0,003 – 0,2) % mol"},{"name":"H2","range":"(0,5 – 10,5) % mol"}],"parameters_en":[{"name":"C1","range":"(86,2 – 99,9) % mol"},{"name":"C2","range":"(0,01 – 7,5) % mol"},{"name":"C3","range":"(0,05 – 2,0) % mol"},{"name":"i-C4","range":"(0,005 – 0,4) % mol"},{"name":"n-C4","range":"(0,005 – 0,3) % mol"},{"name":"i-C5","range":"(0,003 – 0,2) % mol"},{"name":"n-C5","range":"(0,003 – 0,1) % mol"},{"name":"neo-C5","range":"(0,001 – 0,02) % mol"},{"name":"n-C6+","range":"(0,001 – 0,15) % mol"},{"name":"N2","range":"(0,15 – 3,5) % mol"},{"name":"CO2","range":"(0,05 – 1,5) % mol"},{"name":"O2","range":"(0,003 – 0,2) % mol"},{"name":"H2","range":"(0,5 – 10,5) % mol"}],"technique":"Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","techniques":["Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)"],"technique_en":"Gas chromatography with thermal conductivity detection (GC-TCD)","computed":[],"computed_en":[],"activity":"Skład gazu w zakresie rozszerzonym\nZakres:\nC1 (86,2 – 99,9) % mol\nC2 (0,01 – 7,5) % mol\nC3 (0,05 – 2,0) % mol\ni-C4 (0,005 – 0,4) % mol\nn-C4 (0,005 – 0,3) % mol\ni-C5 (0,003 – 0,2) % mol\nn-C5 (0,003 – 0,1) % mol\nneo-C5 (0,001 – 0,02) % mol\nn-C6+ (0,001 – 0,15) % mol\nN2 (0,15 – 3,5) % mol\nCO2 (0,05 – 1,5) % mol\nO2 (0,003 – 0,2) % mol\nH2 (0,5 – 10,5) % mol\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","reference":"ZLB-Kraków-10 Wydanie 1 z dnia 05.02.2024 r.","norm_bases":["ZLB-Kraków-10 Wydanie 1 z dnia 05.02.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny Skład gazu w zakresie rozszerzonym\nZakres:\nC1 (86,2 – 99,9) % mol\nC2 (0,01 – 7,5) % mol\nC3 (0,05 – 2,0) % mol\ni-C4 (0,005 – 0,4) % mol\nn-C4 (0,005 – 0,3) % mol\ni-C5 (0,003 – 0,2) % mol\nn-C5 (0,003 – 0,1) % mol\nneo-C5 (0,001 – 0,02) % mol\nn-C6+ (0,001 – 0,15) % mol\nN2 (0,15 – 3,5) % mol\nCO2 (0,05 – 1,5) % mol\nO2 (0,003 – 0,2) % mol\nH2 (0,5 – 10,5) % mol\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) ZLB-Kraków-10 Wydanie 1 z dnia 05.02.2024 r. Paliwa gazowe: gaz ziemny Sklad gazu w zakresie rozszerzonym\nZakres:\nC1 (86,2 – 99,9) % mol\nC2 (0,01 – 7,5) % mol\nC3 (0,05 – 2,0) % mol\ni-C4 (0,005 – 0,4) % mol\nn-C4 (0,005 – 0,3) % mol\ni-C5 (0,003 – 0,2) % mol\nn-C5 (0,003 – 0,1) % mol\nneo-C5 (0,001 – 0,02) % mol\nn-C6+ (0,001 – 0,15) % mol\nN2 (0,15 – 3,5) % mol\nCO2 (0,05 – 1,5) % mol\nO2 (0,003 – 0,2) % mol\nH2 (0,5 – 10,5) % mol\nMetoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) ZLB-Krakow-10 Wydanie 1 z dnia 05.02.2024 r.","categories":["petro"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gaseous fuels: natural gas Gas composition in the extended range Gas chromatography with thermal conductivity detection (GC-TCD) C1 C2 C3 i-C4 n-C4 i-C5 n-C5 neo-C5 n-C6+ N2 CO2 O2 H2 ZLB-Kraków-10 Wydanie 1 z dnia 05.02.2024 r.","parameters_zh":[{"name":"C1","range":"(86,2 – 99,9) % mol"},{"name":"C2","range":"(0,01 – 7,5) % mol"},{"name":"C3","range":"(0,05 – 2,0) % mol"},{"name":"i-C4","range":"(0,005 – 0,4) % mol"},{"name":"n-C4","range":"(0,005 – 0,3) % mol"},{"name":"i-C5","range":"(0,003 – 0,2) % mol"},{"name":"n-C5","range":"(0,003 – 0,1) % mol"},{"name":"新戊烷（neo-C5）","range":"(0,001 – 0,02) % mol"},{"name":"n-C6+","range":"(0,001 – 0,15) % mol"},{"name":"N2","range":"(0,15 – 3,5) % mol"},{"name":"CO2","range":"(0,05 – 1,5) % mol"},{"name":"O2","range":"(0,003 – 0,2) % mol"},{"name":"H2","range":"(0,5 – 10,5) % mol"}],"search_zh":"气体燃料：天然气 气相色谱-热导检测法（GC-TCD） 新戊烷（neo-C5） CO2 O2 ZLB-Kraków-10 Wydanie 1 z dnia 05.02.2024 r.","technique_zh":"气相色谱-热导检测法（GC-TCD）","test_object_zh":"气体燃料：天然气"},{"_id":"6a5dc9a9f1c10c8ce8259f2f","lab_id":"69ad52a3de79e566650fb975","country":"PL","accr_number":"AB 1780","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","test_object_en":"Gaseous fuels: natural gas","methodology":"Ciepło spalania, wartość opałowa, liczba Wobbego, gęstość względna (z obliczeń)","methodology_en":"Heat of combustion, net calorific value, Wobbe index, relative density (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania, wartość opałowa, liczba Wobbego, gęstość względna (z obliczeń)","reference":"PN-EN ISO 6976:2016-11","norm_bases":["PN-EN ISO 6976:2016-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny Ciepło spalania, wartość opałowa, liczba Wobbego, gęstość względna (z obliczeń) PN-EN ISO 6976:2016-11 Paliwa gazowe: gaz ziemny Cieplo spalania, wartosc opalowa, liczba Wobbego, gestosc wzgledna (z obliczen) PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gaseous fuels: natural gas Heat of combustion, net calorific value, Wobbe index, relative density (calculated) PN-EN ISO 6976:2016-11","search_zh":"气体燃料：天然气 PN-EN ISO 6976:2016-11","test_object_zh":"气体燃料：天然气"},{"_id":"6a5dc9a9f1c10c8ce8259f30","lab_id":"69ad52a3de79e566650fb975","country":"PL","accr_number":"AB 1780","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","test_object_en":"Gaseous fuels: natural gas","methodology":"Stężenie tetrahydrotiofenu (THT)","methodology_en":"Tetrahydrothiophene (THT) concentration","parameters":[{"name":"Zakres","range":"(10,50 – 73,70) mg/m3"}],"parameters_en":[{"name":"Range","range":"(10,50 – 73,70) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-fotometryczną (GC-FPD)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-fotometryczną (GC-FPD)"],"technique_en":"Gas chromatography with flame photometric detection (GC-FPD)","computed":[],"computed_en":[],"activity":"Stężenie tetrahydrotiofenu (THT)\nZakres (10,50 – 73,70) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-fotometryczną (GC-FPD)","reference":"ZLB-Kraków-03 Wydanie 7 z dnia 18.09.2024 r.","norm_bases":["ZLB-Kraków-03 Wydanie 7 z dnia 18.09.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny Stężenie tetrahydrotiofenu (THT)\nZakres (10,50 – 73,70) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-fotometryczną (GC-FPD) ZLB-Kraków-03 Wydanie 7 z dnia 18.09.2024 r. Paliwa gazowe: gaz ziemny Stezenie tetrahydrotiofenu (THT)\nZakres (10,50 – 73,70) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-fotometryczna (GC-FPD) ZLB-Krakow-03 Wydanie 7 z dnia 18.09.2024 r.","categories":["petro"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gaseous fuels: natural gas Tetrahydrothiophene (THT) concentration Gas chromatography with flame photometric detection (GC-FPD) Range ZLB-Kraków-03 Wydanie 7 z dnia 18.09.2024 r.","parameters_zh":[{"name":"范围","range":"(10,50 – 73,70) mg/m3"}],"search_zh":"气体燃料：天然气 四氢噻吩（THT）浓度 气相色谱-火焰光度检测法（GC-FPD） 范围 ZLB-Kraków-03 Wydanie 7 z dnia 18.09.2024 r.","test_object_zh":"气体燃料：天然气","technique_zh":"气相色谱-火焰光度检测法（GC-FPD）","methodology_zh":"四氢噻吩（THT）浓度"},{"_id":"6a5dc9a9f1c10c8ce8259f31","lab_id":"69ad52a3de79e566650fb975","country":"PL","accr_number":"AB 1780","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","test_object_en":"Gaseous fuels: natural gas","methodology":"Stężenie tetrahydrotiofenu (THT)","methodology_en":"Tetrahydrothiophene (THT) concentration","parameters":[{"name":"Zakres","range":"(10,50 – 73,70) mg/m3"}],"parameters_en":[{"name":"Range","range":"(10,50 – 73,70) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją pulsacyjno-płomieniowofotometryczną (GC-PFPD)","techniques":["Metoda chromatografii gazowej z detekcją pulsacyjno-płomieniowofotometryczną (GC-PFPD)"],"technique_en":"Gas chromatography with pulsed flame photometric detection (GC-PFPD)","computed":[],"computed_en":[],"activity":"Stężenie tetrahydrotiofenu (THT)\nZakres (10,50 – 73,70) mg/m3\nMetoda chromatografii gazowej z detekcją pulsacyjno-płomieniowofotometryczną (GC-PFPD)","reference":"ZLB-Kraków-03 Wydanie 7 z dnia 18.09.2024 r.","norm_bases":["ZLB-Kraków-03 Wydanie 7 z dnia 18.09.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny Stężenie tetrahydrotiofenu (THT)\nZakres (10,50 – 73,70) mg/m3\nMetoda chromatografii gazowej z detekcją pulsacyjno-płomieniowofotometryczną (GC-PFPD) ZLB-Kraków-03 Wydanie 7 z dnia 18.09.2024 r. Paliwa gazowe: gaz ziemny Stezenie tetrahydrotiofenu (THT)\nZakres (10,50 – 73,70) mg/m3\nMetoda chromatografii gazowej z detekcja pulsacyjno-plomieniowofotometryczna (GC-PFPD) ZLB-Krakow-03 Wydanie 7 z dnia 18.09.2024 r.","categories":["petro"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gaseous fuels: natural gas Tetrahydrothiophene (THT) concentration Gas chromatography with pulsed flame photometric detection (GC-PFPD) Range ZLB-Kraków-03 Wydanie 7 z dnia 18.09.2024 r.","parameters_zh":[{"name":"范围","range":"(10,50 – 73,70) mg/m3"}],"search_zh":"气体燃料：天然气 四氢噻吩（THT）浓度 范围 ZLB-Kraków-03 Wydanie 7 z dnia 18.09.2024 r.","test_object_zh":"气体燃料：天然气","methodology_zh":"四氢噻吩（THT）浓度"},{"_id":"6a5dc9a9f1c10c8ce8259f32","lab_id":"69ad52a3de79e566650fb975","country":"PL","accr_number":"AB 1780","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","test_object_en":"Gaseous fuels: natural gas","methodology":"Temperatura punktu rosy wody","methodology_en":"Water dew point temperature","parameters":[{"name":"Zakres","range":"((-50) – 5) °C"}],"parameters_en":[{"name":"Range","range":"((-50) – 5) °C"}],"technique":"Metoda kondensacji par na chłodzonej powierzchni lustra","techniques":["Metoda kondensacji par na chłodzonej powierzchni lustra"],"technique_en":"Vapour condensation on a chilled mirror surface method","computed":[],"computed_en":[],"activity":"Temperatura punktu rosy wody\nZakres ((-50) – 5) °C\nMetoda kondensacji par na chłodzonej powierzchni lustra","reference":"PN-EN ISO 6327:2010","norm_bases":["PN-EN ISO 6327:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny Temperatura punktu rosy wody\nZakres ((-50) – 5) °C\nMetoda kondensacji par na chłodzonej powierzchni lustra PN-EN ISO 6327:2010 Paliwa gazowe: gaz ziemny Temperatura punktu rosy wody\nZakres ((-50) – 5) °C\nMetoda kondensacji par na chlodzonej powierzchni lustra PN-EN ISO 6327:2010","categories":["petro","water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gaseous fuels: natural gas Water dew point temperature Vapour condensation on a chilled mirror surface method Range PN-EN ISO 6327:2010","parameters_zh":[{"name":"范围","range":"((-50) – 5) °C"}],"search_zh":"气体燃料：天然气 水露点温度 冷却镜面凝露法 范围 PN-EN ISO 6327:2010","test_object_zh":"气体燃料：天然气","methodology_zh":"水露点温度","technique_zh":"冷却镜面凝露法"},{"_id":"6a5dc9a9f1c10c8ce8259f33","lab_id":"69ad52a3de79e566650fb975","country":"PL","accr_number":"AB 1780","accr_body":"PCA","test_object":"Procesowe chromatografy gazowe","test_object_en":"Process gas chromatographs","methodology":"Kontrola pomiarowo-analityczna","methodology_en":"Measurement and analytical control","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Kontrola pomiarowo-analityczna","reference":"ST-IGG-0205:2023 pkt. 4.5.1","norm_bases":["ST-IGG-0205:2023 pkt. 4.5.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Procesowe chromatografy gazowe Kontrola pomiarowo-analityczna ST-IGG-0205:2023 pkt. 4.5.1 Procesowe chromatografy gazowe Kontrola pomiarowo-analityczna ST-IGG-0205:2023 pkt. 4.5.1","categories":["other"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Process gas chromatographs Measurement and analytical control ST-IGG-0205:2023 pkt. 4.5.1","methodology_zh":"测量与分析监控","search_zh":"测量与分析监控 ST-IGG-0205:2023 pkt. 4.5.1"},{"_id":"6a5dc9a9f1c10c8ce8259f34","lab_id":"69ad52a3de79e566650fb975","country":"PL","accr_number":"AB 1780","accr_body":"PCA","test_object":"Procesowe analizatory temperatury punktu rosy wody","test_object_en":"Process water dew point analysers","methodology":"Kontrola pomiarowo-analityczna","methodology_en":"Measurement and analytical control","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Kontrola pomiarowo-analityczna","reference":"ST-IGG-0209:2021 pkt 5,10.2","norm_bases":["ST-IGG-0209:2021 pkt 5,10.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Procesowe analizatory temperatury punktu rosy wody Kontrola pomiarowo-analityczna ST-IGG-0209:2021 pkt 5,10.2 Procesowe analizatory temperatury punktu rosy wody Kontrola pomiarowo-analityczna ST-IGG-0209:2021 pkt 5,10.2","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Process water dew point analysers Measurement and analytical control ST-IGG-0209:2021 pkt 5,10.2","methodology_zh":"测量与分析监控","search_zh":"测量与分析监控 ST-IGG-0209:2021 pkt 5,10.2"},{"_id":"6a5dc9a9f1c10c8ce8259f35","lab_id":"69ad52a3de79e566650fb975","country":"PL","accr_number":"AB 1780","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","test_object_en":"Gaseous fuels: natural gas","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"ZLB-Kraków-01 Wydanie 6 z dnia 18.09.2023 r.","norm_bases":["ZLB-Kraków-01 Wydanie 6 z dnia 18.09.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny Pobieranie próbek do badań chemicznych i fizycznych ZLB-Kraków-01 Wydanie 6 z dnia 18.09.2023 r. Paliwa gazowe: gaz ziemny Pobieranie probek do badan chemicznych i fizycznych ZLB-Krakow-01 Wydanie 6 z dnia 18.09.2023 r.","categories":["petro"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gaseous fuels: natural gas Sampling for chemical and physical testing ZLB-Kraków-01 Wydanie 6 z dnia 18.09.2023 r.","methodology_zh":"化学与物理检测用样品采集","search_zh":"气体燃料：天然气 化学与物理检测用样品采集 ZLB-Kraków-01 Wydanie 6 z dnia 18.09.2023 r.","test_object_zh":"气体燃料：天然气"},{"_id":"6a5dc9a9f1c10c8ce8259f36","lab_id":"69ad52a3de79e566650fb975","country":"PL","accr_number":"AB 1780","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","test_object_en":"Gaseous fuels: natural gas","methodology":"Skład gazu w zakresie podstawowym","methodology_en":"Gas composition in the basic range","parameters":[{"name":"C1","range":"(86,2 – 99,9) % mol"},{"name":"C2","range":"(0,01 – 7,5) % mol"},{"name":"C3","range":"(0,05 – 2,0) % mol"},{"name":"i-C4","range":"(0,005 – 0,4) % mol"},{"name":"n-C4","range":"(0,005 – 0,3) % mol"},{"name":"i-C5","range":"(0,003 – 0,2) % mol"},{"name":"n-C5","range":"(0,003 – 0,1) % mol"},{"name":"neo-C5","range":"(0,001 – 0,02) % mol"},{"name":"n-C6+","range":"(0,001 – 0,15) % mol"},{"name":"N2","range":"(0,15 – 3,5) %"},{"name":"CO2","range":"(0,05 – 1,5) %"},{"name":"O2","range":"(0,003 – 0,2) %"}],"parameters_en":[{"name":"C1","range":"(86,2 – 99,9) % mol"},{"name":"C2","range":"(0,01 – 7,5) % mol"},{"name":"C3","range":"(0,05 – 2,0) % mol"},{"name":"i-C4","range":"(0,005 – 0,4) % mol"},{"name":"n-C4","range":"(0,005 – 0,3) % mol"},{"name":"i-C5","range":"(0,003 – 0,2) % mol"},{"name":"n-C5","range":"(0,003 – 0,1) % mol"},{"name":"neo-C5","range":"(0,001 – 0,02) % mol"},{"name":"n-C6+","range":"(0,001 – 0,15) % mol"},{"name":"N2","range":"(0,15 – 3,5) %"},{"name":"CO2","range":"(0,05 – 1,5) %"},{"name":"O2","range":"(0,003 – 0,2) %"}],"technique":"Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","techniques":["Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)"],"technique_en":"Gas chromatography with thermal conductivity detection (GC-TCD)","computed":[],"computed_en":[],"activity":"Skład gazu w zakresie podstawowym\nZakres:\nC1 (86,2 – 99,9) % mol\nC2 (0,01 – 7,5) % mol\nC3 (0,05 – 2,0) % mol\ni-C4 (0,005 – 0,4) % mol\nn-C4 (0,005 – 0,3) % mol\ni-C5 (0,003 – 0,2) % mol\nn-C5 (0,003 – 0,1) % mol\nneo-C5 (0,001 – 0,02) % mol\nn-C6+ (0,001 – 0,15) % mol\nN2 (0,15 – 3,5) %\nCO2 (0,05 – 1,5) %\nO2 (0,003 – 0,2) %\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","reference":"ZLB-Kraków-02 Wydanie 7 z dnia 18.09.2024 r.","norm_bases":["ZLB-Kraków-02 Wydanie 7 z dnia 18.09.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny Skład gazu w zakresie podstawowym\nZakres:\nC1 (86,2 – 99,9) % mol\nC2 (0,01 – 7,5) % mol\nC3 (0,05 – 2,0) % mol\ni-C4 (0,005 – 0,4) % mol\nn-C4 (0,005 – 0,3) % mol\ni-C5 (0,003 – 0,2) % mol\nn-C5 (0,003 – 0,1) % mol\nneo-C5 (0,001 – 0,02) % mol\nn-C6+ (0,001 – 0,15) % mol\nN2 (0,15 – 3,5) %\nCO2 (0,05 – 1,5) %\nO2 (0,003 – 0,2) %\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) ZLB-Kraków-02 Wydanie 7 z dnia 18.09.2024 r. Paliwa gazowe: gaz ziemny Sklad gazu w zakresie podstawowym\nZakres:\nC1 (86,2 – 99,9) % mol\nC2 (0,01 – 7,5) % mol\nC3 (0,05 – 2,0) % mol\ni-C4 (0,005 – 0,4) % mol\nn-C4 (0,005 – 0,3) % mol\ni-C5 (0,003 – 0,2) % mol\nn-C5 (0,003 – 0,1) % mol\nneo-C5 (0,001 – 0,02) % mol\nn-C6+ (0,001 – 0,15) % mol\nN2 (0,15 – 3,5) %\nCO2 (0,05 – 1,5) %\nO2 (0,003 – 0,2) %\nMetoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) ZLB-Krakow-02 Wydanie 7 z dnia 18.09.2024 r.","categories":["petro"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gaseous fuels: natural gas Gas composition in the basic range Gas chromatography with thermal conductivity detection (GC-TCD) C1 C2 C3 i-C4 n-C4 i-C5 n-C5 neo-C5 n-C6+ N2 CO2 O2 ZLB-Kraków-02 Wydanie 7 z dnia 18.09.2024 r.","parameters_zh":[{"name":"C1","range":"(86,2 – 99,9) % mol"},{"name":"C2","range":"(0,01 – 7,5) % mol"},{"name":"C3","range":"(0,05 – 2,0) % mol"},{"name":"i-C4","range":"(0,005 – 0,4) % mol"},{"name":"n-C4","range":"(0,005 – 0,3) % mol"},{"name":"i-C5","range":"(0,003 – 0,2) % mol"},{"name":"n-C5","range":"(0,003 – 0,1) % mol"},{"name":"新戊烷（neo-C5）","range":"(0,001 – 0,02) % mol"},{"name":"n-C6+","range":"(0,001 – 0,15) % mol"},{"name":"N2","range":"(0,15 – 3,5) %"},{"name":"CO2","range":"(0,05 – 1,5) %"},{"name":"O2","range":"(0,003 – 0,2) %"}],"search_zh":"气体燃料：天然气 基本范围内的气体组成 气相色谱-热导检测法（GC-TCD） 新戊烷（neo-C5） CO2 O2 ZLB-Kraków-02 Wydanie 7 z dnia 18.09.2024 r.","technique_zh":"气相色谱-热导检测法（GC-TCD）","test_object_zh":"气体燃料：天然气","methodology_zh":"基本范围内的气体组成"},{"_id":"6a5dc9a9f1c10c8ce8259f37","lab_id":"69ad52a3de79e566650fb975","country":"PL","accr_number":"AB 1780","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","test_object_en":"Gaseous fuels: natural gas","methodology":"Ciepło spalania, wartość opałowa, liczba Wobbego, gęstość względna (z obliczeń)","methodology_en":"Heat of combustion, net calorific value, Wobbe index, relative density (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania, wartość opałowa, liczba Wobbego, gęstość względna (z obliczeń)","reference":"PN-EN ISO 6976:2016-11","norm_bases":["PN-EN ISO 6976:2016-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny Ciepło spalania, wartość opałowa, liczba Wobbego, gęstość względna (z obliczeń) PN-EN ISO 6976:2016-11 Paliwa gazowe: gaz ziemny Cieplo spalania, wartosc opalowa, liczba Wobbego, gestosc wzgledna (z obliczen) PN-EN ISO 6976:2016-11","categories":["petro"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gaseous fuels: natural gas Heat of combustion, net calorific value, Wobbe index, relative density (calculated) PN-EN ISO 6976:2016-11","search_zh":"气体燃料：天然气 PN-EN ISO 6976:2016-11","test_object_zh":"气体燃料：天然气"},{"_id":"6a5dc9a9f1c10c8ce8259f38","lab_id":"69ad52a3de79e566650fb975","country":"PL","accr_number":"AB 1780","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","test_object_en":"Gaseous fuels: natural gas","methodology":"Stężenie tetrahydrotiofenu (THT)","methodology_en":"Tetrahydrothiophene (THT) concentration","parameters":[{"name":"Zakres","range":"(10,50 – 73,70) mg/m3"}],"parameters_en":[{"name":"Range","range":"(10,50 – 73,70) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-fotometryczną (GC-FPD)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-fotometryczną (GC-FPD)"],"technique_en":"Gas chromatography with flame photometric detection (GC-FPD)","computed":[],"computed_en":[],"activity":"Stężenie tetrahydrotiofenu (THT)\nZakres (10,50 – 73,70) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-fotometryczną (GC-FPD)","reference":"ZLB-Kraków-03 Wydanie 7 z dnia 18.09.2024 r.","norm_bases":["ZLB-Kraków-03 Wydanie 7 z dnia 18.09.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny Stężenie tetrahydrotiofenu (THT)\nZakres (10,50 – 73,70) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-fotometryczną (GC-FPD) ZLB-Kraków-03 Wydanie 7 z dnia 18.09.2024 r. Paliwa gazowe: gaz ziemny Stezenie tetrahydrotiofenu (THT)\nZakres (10,50 – 73,70) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-fotometryczna (GC-FPD) ZLB-Krakow-03 Wydanie 7 z dnia 18.09.2024 r.","categories":["petro"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gaseous fuels: natural gas Tetrahydrothiophene (THT) concentration Gas chromatography with flame photometric detection (GC-FPD) Range ZLB-Kraków-03 Wydanie 7 z dnia 18.09.2024 r.","parameters_zh":[{"name":"范围","range":"(10,50 – 73,70) mg/m3"}],"search_zh":"气体燃料：天然气 四氢噻吩（THT）浓度 气相色谱-火焰光度检测法（GC-FPD） 范围 ZLB-Kraków-03 Wydanie 7 z dnia 18.09.2024 r.","test_object_zh":"气体燃料：天然气","technique_zh":"气相色谱-火焰光度检测法（GC-FPD）","methodology_zh":"四氢噻吩（THT）浓度"},{"_id":"6a5dc9a9f1c10c8ce8259f39","lab_id":"69ad52a3de79e566650fb975","country":"PL","accr_number":"AB 1780","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","test_object_en":"Gaseous fuels: natural gas","methodology":"Stężenie tetrahydrotiofenu (THT)","methodology_en":"Tetrahydrothiophene (THT) concentration","parameters":[{"name":"Zakres","range":"(10,50 – 73,70) mg/m3"}],"parameters_en":[{"name":"Range","range":"(10,50 – 73,70) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją pulsacyjno-płomieniowofotometryczną (GC-PFPD)","techniques":["Metoda chromatografii gazowej z detekcją pulsacyjno-płomieniowofotometryczną (GC-PFPD)"],"technique_en":"Gas chromatography with pulsed flame photometric detection (GC-PFPD)","computed":[],"computed_en":[],"activity":"Stężenie tetrahydrotiofenu (THT)\nZakres (10,50 – 73,70) mg/m3\nMetoda chromatografii gazowej z detekcją pulsacyjno-płomieniowofotometryczną (GC-PFPD)","reference":"ZLB-Kraków-03 Wydanie 7 z dnia 18.09.2024 r.","norm_bases":["ZLB-Kraków-03 Wydanie 7 z dnia 18.09.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny Stężenie tetrahydrotiofenu (THT)\nZakres (10,50 – 73,70) mg/m3\nMetoda chromatografii gazowej z detekcją pulsacyjno-płomieniowofotometryczną (GC-PFPD) ZLB-Kraków-03 Wydanie 7 z dnia 18.09.2024 r. Paliwa gazowe: gaz ziemny Stezenie tetrahydrotiofenu (THT)\nZakres (10,50 – 73,70) mg/m3\nMetoda chromatografii gazowej z detekcja pulsacyjno-plomieniowofotometryczna (GC-PFPD) ZLB-Krakow-03 Wydanie 7 z dnia 18.09.2024 r.","categories":["petro"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gaseous fuels: natural gas Tetrahydrothiophene (THT) concentration Gas chromatography with pulsed flame photometric detection (GC-PFPD) Range ZLB-Kraków-03 Wydanie 7 z dnia 18.09.2024 r.","parameters_zh":[{"name":"范围","range":"(10,50 – 73,70) mg/m3"}],"search_zh":"气体燃料：天然气 四氢噻吩（THT）浓度 范围 ZLB-Kraków-03 Wydanie 7 z dnia 18.09.2024 r.","test_object_zh":"气体燃料：天然气","methodology_zh":"四氢噻吩（THT）浓度"},{"_id":"6a5dc9a9f1c10c8ce8259f3a","lab_id":"69ad52a3de79e566650fb975","country":"PL","accr_number":"AB 1780","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","test_object_en":"Gaseous fuels: natural gas","methodology":"Temperatura punktu rosy wody","methodology_en":"Water dew point temperature","parameters":[{"name":"Zakres","range":"((-50) – 5) °C"}],"parameters_en":[{"name":"Range","range":"((-50) – 5) °C"}],"technique":"Metoda kondensacji par na chłodzonej powierzchni lustra","techniques":["Metoda kondensacji par na chłodzonej powierzchni lustra"],"technique_en":"Vapour condensation on a chilled mirror surface method","computed":[],"computed_en":[],"activity":"Temperatura punktu rosy wody\nZakres ((-50) – 5) °C\nMetoda kondensacji par na chłodzonej powierzchni lustra","reference":"PN-EN ISO 6327:2010","norm_bases":["PN-EN ISO 6327:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny Temperatura punktu rosy wody\nZakres ((-50) – 5) °C\nMetoda kondensacji par na chłodzonej powierzchni lustra PN-EN ISO 6327:2010 Paliwa gazowe: gaz ziemny Temperatura punktu rosy wody\nZakres ((-50) – 5) °C\nMetoda kondensacji par na chlodzonej powierzchni lustra PN-EN ISO 6327:2010","categories":["petro","water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gaseous fuels: natural gas Water dew point temperature Vapour condensation on a chilled mirror surface method Range PN-EN ISO 6327:2010","parameters_zh":[{"name":"范围","range":"((-50) – 5) °C"}],"search_zh":"气体燃料：天然气 水露点温度 冷却镜面凝露法 范围 PN-EN ISO 6327:2010","test_object_zh":"气体燃料：天然气","methodology_zh":"水露点温度","technique_zh":"冷却镜面凝露法"},{"_id":"6a5dc9a9f1c10c8ce8259f3b","lab_id":"69ad52a3de79e566650fb975","country":"PL","accr_number":"AB 1780","accr_body":"PCA","test_object":"Paliwa gazowe: gaz ziemny","test_object_en":"Gaseous fuels: natural gas","methodology":"Stężenie siarki całkowitej","methodology_en":"Total sulphur concentration","parameters":[{"name":"Zakres","range":"(1,30 – 42,46) mg/m3"}],"parameters_en":[{"name":"Range","range":"(1,30 – 42,46) mg/m3"}],"technique":"Metoda fluorescencji w nadfiolecie","techniques":["Metoda fluorescencji w nadfiolecie"],"technique_en":"Ultraviolet fluorescence method","computed":[],"computed_en":[],"activity":"Stężenie siarki całkowitej\nZakres (1,30 – 42,46) mg/m3\nMetoda fluorescencji w nadfiolecie","reference":"ZLB-Kraków-04 Wydanie 7 z dnia 18.09.2024 r.","norm_bases":["ZLB-Kraków-04 Wydanie 7 z dnia 18.09.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa gazowe: gaz ziemny Stężenie siarki całkowitej\nZakres (1,30 – 42,46) mg/m3\nMetoda fluorescencji w nadfiolecie ZLB-Kraków-04 Wydanie 7 z dnia 18.09.2024 r. Paliwa gazowe: gaz ziemny Stezenie siarki calkowitej\nZakres (1,30 – 42,46) mg/m3\nMetoda fluorescencji w nadfiolecie ZLB-Krakow-04 Wydanie 7 z dnia 18.09.2024 r.","categories":["petro"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gaseous fuels: natural gas Total sulphur concentration Ultraviolet fluorescence method Range ZLB-Kraków-04 Wydanie 7 z dnia 18.09.2024 r.","parameters_zh":[{"name":"范围","range":"(1,30 – 42,46) mg/m3"}],"search_zh":"气体燃料：天然气 紫外荧光法 范围 ZLB-Kraków-04 Wydanie 7 z dnia 18.09.2024 r.","technique_zh":"紫外荧光法","test_object_zh":"气体燃料：天然气"},{"_id":"6a5dc9a9f1c10c8ce8259f3c","lab_id":"69ad52a3de79e566650fb975","country":"PL","accr_number":"AB 1780","accr_body":"PCA","test_object":"Procesowe chromatografy gazowe","test_object_en":"Process gas chromatographs","methodology":"Kontrola pomiarowo-analityczna","methodology_en":"Measurement and analytical control","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Kontrola pomiarowo-analityczna","reference":"ST-IGG-0205:2023 pkt. 4.5.1","norm_bases":["ST-IGG-0205:2023 pkt. 4.5.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Procesowe chromatografy gazowe Kontrola pomiarowo-analityczna ST-IGG-0205:2023 pkt. 4.5.1 Procesowe chromatografy gazowe Kontrola pomiarowo-analityczna ST-IGG-0205:2023 pkt. 4.5.1","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Process gas chromatographs Measurement and analytical control ST-IGG-0205:2023 pkt. 4.5.1","methodology_zh":"测量与分析监控","search_zh":"测量与分析监控 ST-IGG-0205:2023 pkt. 4.5.1"},{"_id":"6a5dc9a9f1c10c8ce8259f3d","lab_id":"69ad52a3de79e566650fb975","country":"PL","accr_number":"AB 1780","accr_body":"PCA","test_object":"Procesowe analizatory temperatury punktu rosy wody","test_object_en":"Process water dew point analysers","methodology":"Kontrola pomiarowo-analityczna","methodology_en":"Measurement and analytical control","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Kontrola pomiarowo-analityczna","reference":"ST-IGG-0209:2021 pkt 5,10.2","norm_bases":["ST-IGG-0209:2021 pkt 5,10.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Procesowe analizatory temperatury punktu rosy wody Kontrola pomiarowo-analityczna ST-IGG-0209:2021 pkt 5,10.2 Procesowe analizatory temperatury punktu rosy wody Kontrola pomiarowo-analityczna ST-IGG-0209:2021 pkt 5,10.2","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Process water dew point analysers Measurement and analytical control ST-IGG-0209:2021 pkt 5,10.2","methodology_zh":"测量与分析监控","search_zh":"测量与分析监控 ST-IGG-0209:2021 pkt 5,10.2"}],"has_pdf":true}