{"lab":{"_id":"69ad52a3de79e566650fb96d","accr_number":"AB 1776","country":"PL","accr_body":"PCA","address":"SPS PV&T LABORATORY, ul. Podgórki Tynieckie 2; 30-399 Kraków","categories":["electronics","construction"],"city":"Kraków","imported_at":"2026-03-08T10:42:43.265Z","methods_count":97,"name":"APTIV SERVICES POLAND SPÓŁKA AKCYJNA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1776.pdf"],"scope_summary":"","search_text":"aptiv services poland spółka akcyjna sps pv&t laboratory, ul. podgórki tynieckie 2; 30-399 kraków materials other electronics pharma automotive metrology construction water environment petro food","status":"active","updated_at":"2026-03-08T14:50:54.567Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:54.567Z","location":{"type":"Point","coordinates":[19.945,50.0647]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%201776,podmiot.html","fields_of_testing":[{"codes":"E/6","pl":"Badania elektryczne i elektroniczne wyrobów i wyposażenia elektrycznego","en":"Electric and electronic tests of electrical products and equipment"},{"codes":"H/6","pl":"Badania ogniowe wyrobów i wyposażenia elektrycznego","en":"Fire tests of electrical products and equipment"},{"codes":"J/6","pl":"Badania mechaniczne wyrobów i wyposażenia elektrycznego","en":"Mechanical tests of electrical products and equipment"},{"codes":"N/6","pl":"Badania właściwości fizycznych wyrobów i wyposażenia elektrycznego","en":"Tests of physical properties of electrical products and equipment"},{"codes":"F/6","pl":"Badania kompatybilności elektromagnetycznej (EMC wyrobów i wyposażenia elektrycznego","en":"Tests of physical properties of electrical products and equipment"}],"issue":{"no":"7","date":"04.03.2026"},"parse_date":"2026-07-20T07:09:29.199Z","parse_source":"script-pdfplumber","map_coord":[49.99832,19.851638],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":54,"electronics":33,"construction":10,"environment":3,"materials":2,"food":1,"water":1},"category_scores":{"other":28.04,"electronics":10.47,"construction":0.96,"environment":0.09,"materials":0.04,"food":0.01,"water":0.01},"has_zh":true},"methods":[{"_id":"6a5dc9a9f1c10c8ce8259e98","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Badania wizualne, manualne i funkcjonalne","methodology_en":"Visual, manual and functional testing","parameters":[{"name":"powiększenie","range":"do 500 x"}],"parameters_en":[{"name":"magnification","range":"do 500 x"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania wizualne, manualne i funkcjonalne\npowiększenie do 500 x","reference":"IEC 60512-1-1:2002 | ISO 8092-2:2005-12-01 (p. 4.2) | ISO 8092-2:2023-09 (p. 4.2) | ISO 8092-5:2021-01 (p. 4.2, 4.5) | ISO 19072-2:2019-12 (p. 4.2) | ISO 19072-2:2007-10-01 (p. 4.2) VW 75174:2018-10 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2; P 0.1; P 6.2; P 6.3; P 14.2; L 8.1; L 5.1; L 5.2; L 15.1; L 18.1; L 19.8; L 20.4; P 21.1; L 23.2) VW 80332:2024-01 (TG 0, TG 1) LV 214:2010-03 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) GS 95006-7-1:2016-03 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) GS 95006-7-1:2021-11 (E 0.1 z wyłączeniem oceny w paragrafie 6.18.3; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.4) MBN 10384:2010-11 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) SAE/USCAR-2:2020-02 (p. 5.1.7, 5.1.8) SAE/USCAR-2:2022-06 (p. 5.1.7, 5.1.8) SAE/USCAR-2:2024-12 (p. 5.1.7, 5.1.8) SAE/USCAR-21:2020-01 (p. 4.2; 4.3) A 009 000 04 99:2013-07 (p. 3.1; 3.11; 3.12) Audi Prufmatrix:2017-02-15 MVL 9 902 1040 Delphi 33330950:2016-10-04 (p. 2.1; 5.3.5) MVL 9 902 10 40 Aptiv 33330950-INS01:2022-05-09 (p. 5.3.2; 5.3.3) MVL 9 902 10 40 Aptiv 33330950-INS02:2022-05-09 (p. 2.1; 3.2) Scope of accreditation No. AB 1776","norm_bases":["IEC 60512-1-1:2002","ISO 8092-2:2005-12-01 (p. 4.2)","ISO 8092-2:2023-09 (p. 4.2)","ISO 8092-5:2021-01 (p. 4.2, 4.5)","ISO 19072-2:2019-12 (p. 4.2)","ISO 19072-2:2007-10-01 (p. 4.2) VW 75174:2018-10 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2; P 0.1; P 6.2; P 6.3; P 14.2; L 8.1; L 5.1; L 5.2; L 15.1; L 18.1; L 19.8; L 20.4; P 21.1; L 23.2) VW 80332:2024-01 (TG 0, TG 1) LV 214:2010-03 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) GS 95006-7-1:2016-03 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) GS 95006-7-1:2021-11 (E 0.1 z wyłączeniem oceny w paragrafie 6.18.3; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.4) MBN 10384:2010-11 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) SAE/USCAR-2:2020-02 (p. 5.1.7, 5.1.8) SAE/USCAR-2:2022-06 (p. 5.1.7, 5.1.8) SAE/USCAR-2:2024-12 (p. 5.1.7, 5.1.8) SAE/USCAR-21:2020-01 (p. 4.2; 4.3) A 009 000 04 99:2013-07 (p. 3.1; 3.11; 3.12) Audi Prufmatrix:2017-02-15 MVL 9 902 1040 Delphi 33330950:2016-10-04 (p. 2.1; 5.3.5) MVL 9 902 10 40 Aptiv 33330950-INS01:2022-05-09 (p. 5.3.2; 5.3.3) MVL 9 902 10 40 Aptiv 33330950-INS02:2022-05-09 (p. 2.1; 3.2) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Badania wizualne, manualne i funkcjonalne\npowiększenie do 500 x IEC 60512-1-1:2002 | ISO 8092-2:2005-12-01 (p. 4.2) | ISO 8092-2:2023-09 (p. 4.2) | ISO 8092-5:2021-01 (p. 4.2, 4.5) | ISO 19072-2:2019-12 (p. 4.2) | ISO 19072-2:2007-10-01 (p. 4.2) VW 75174:2018-10 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2; P 0.1; P 6.2; P 6.3; P 14.2; L 8.1; L 5.1; L 5.2; L 15.1; L 18.1; L 19.8; L 20.4; P 21.1; L 23.2) VW 80332:2024-01 (TG 0, TG 1) LV 214:2010-03 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) GS 95006-7-1:2016-03 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) GS 95006-7-1:2021-11 (E 0.1 z wyłączeniem oceny w paragrafie 6.18.3; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.4) MBN 10384:2010-11 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) SAE/USCAR-2:2020-02 (p. 5.1.7, 5.1.8) SAE/USCAR-2:2022-06 (p. 5.1.7, 5.1.8) SAE/USCAR-2:2024-12 (p. 5.1.7, 5.1.8) SAE/USCAR-21:2020-01 (p. 4.2; 4.3) A 009 000 04 99:2013-07 (p. 3.1; 3.11; 3.12) Audi Prufmatrix:2017-02-15 MVL 9 902 1040 Delphi 33330950:2016-10-04 (p. 2.1; 5.3.5) MVL 9 902 10 40 Aptiv 33330950-INS01:2022-05-09 (p. 5.3.2; 5.3.3) MVL 9 902 10 40 Aptiv 33330950-INS02:2022-05-09 (p. 2.1; 3.2) Scope of accreditation No. AB 1776 Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Badania wizualne, manualne i funkcjonalne\npowiekszenie do 500 x IEC 60512-1-1:2002 | ISO 8092-2:2005-12-01 (p. 4.2) | ISO 8092-2:2023-09 (p. 4.2) | ISO 8092-5:2021-01 (p. 4.2, 4.5) | ISO 19072-2:2019-12 (p. 4.2) | ISO 19072-2:2007-10-01 (p. 4.2) VW 75174:2018-10 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2; P 0.1; P 6.2; P 6.3; P 14.2; L 8.1; L 5.1; L 5.2; L 15.1; L 18.1; L 19.8; L 20.4; P 21.1; L 23.2) VW 80332:2024-01 (TG 0, TG 1) LV 214:2010-03 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) GS 95006-7-1:2016-03 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) GS 95006-7-1:2021-11 (E 0.1 z wylaczeniem oceny w paragrafie 6.18.3; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.4) MBN 10384:2010-11 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) SAE/USCAR-2:2020-02 (p. 5.1.7, 5.1.8) SAE/USCAR-2:2022-06 (p. 5.1.7, 5.1.8) SAE/USCAR-2:2024-12 (p. 5.1.7, 5.1.8) SAE/USCAR-21:2020-01 (p. 4.2; 4.3) A 009 000 04 99:2013-07 (p. 3.1; 3.11; 3.12) Audi Prufmatrix:2017-02-15 MVL 9 902 1040 Delphi 33330950:2016-10-04 (p. 2.1; 5.3.5) MVL 9 902 10 40 Aptiv 33330950-INS01:2022-05-09 (p. 5.3.2; 5.3.3) MVL 9 902 10 40 Aptiv 33330950-INS02:2022-05-09 (p. 2.1; 3.2) Scope of accreditation No. AB 1776","categories":["electronics"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Visual, manual and functional testing magnification IEC 60512-1-1:2002 | ISO 8092-2:2005-12-01 (p. 4.2) | ISO 8092-2:2023-09 (p. 4.2) | ISO 8092-5:2021-01 (p. 4.2, 4.5) | ISO 19072-2:2019-12 (p. 4.2) | ISO 19072-2:2007-10-01 (p. 4.2) VW 75174:2018-10 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2; P 0.1; P 6.2; P 6.3; P 14.2; L 8.1; L 5.1; L 5.2; L 15.1; L 18.1; L 19.8; L 20.4; P 21.1; L 23.2) VW 80332:2024-01 (TG 0, TG 1) LV 214:2010-03 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) GS 95006-7-1:2016-03 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) GS 95006-7-1:2021-11 (E 0.1 z wyłączeniem oceny w paragrafie 6.18.3; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.4) MBN 10384:2010-11 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) SAE/USCAR-2:2020-02 (p. 5.1.7, 5.1.8) SAE/USCAR-2:2022-06 (p. 5.1.7, 5.1.8) SAE/USCAR-2:2024-12 (p. 5.1.7, 5.1.8) SAE/USCAR-21:2020-01 (p. 4.2; 4.3) A 009 000 04 99:2013-07 (p. 3.1; 3.11; 3.12) Audi Prufmatrix:2017-02-15 MVL 9 902 1040 Delphi 33330950:2016-10-04 (p. 2.1; 5.3.5) MVL 9 902 10 40 Aptiv 33330950-INS01:2022-05-09 (p. 5.3.2; 5.3.3) MVL 9 902 10 40 Aptiv 33330950-INS02:2022-05-09 (p. 2.1; 3.2) Scope of accreditation No. AB 1776","search_zh":"汽车电气与电子设备的部件/组件 IEC 60512-1-1:2002 | ISO 8092-2:2005-12-01 (p. 4.2) | ISO 8092-2:2023-09 (p. 4.2) | ISO 8092-5:2021-01 (p. 4.2, 4.5) | ISO 19072-2:2019-12 (p. 4.2) | ISO 19072-2:2007-10-01 (p. 4.2) VW 75174:2018-10 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2; P 0.1; P 6.2; P 6.3; P 14.2; L 8.1; L 5.1; L 5.2; L 15.1; L 18.1; L 19.8; L 20.4; P 21.1; L 23.2) VW 80332:2024-01 (TG 0, TG 1) LV 214:2010-03 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) GS 95006-7-1:2016-03 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) GS 95006-7-1:2021-11 (E 0.1 z wyłączeniem oceny w paragrafie 6.18.3; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.4) MBN 10384:2010-11 (p. E 0.1; E 6.2; E 6.3; E 14.2; B 8.1; B 5.1; B 5.2; B 15.1; B 18.1; B 19.0; B 19.8; B 20.4; E 21.1; B 23.2) SAE/USCAR-2:2020-02 (p. 5.1.7, 5.1.8) SAE/USCAR-2:2022-06 (p. 5.1.7, 5.1.8) SAE/USCAR-2:2024-12 (p. 5.1.7, 5.1.8) SAE/USCAR-21:2020-01 (p. 4.2; 4.3) A 009 000 04 99:2013-07 (p. 3.1; 3.11; 3.12) Audi Prufmatrix:2017-02-15 MVL 9 902 1040 Delphi 33330950:2016-10-04 (p. 2.1; 5.3.5) MVL 9 902 10 40 Aptiv 33330950-INS01:2022-05-09 (p. 5.3.2; 5.3.3) MVL 9 902 10 40 Aptiv 33330950-INS02:2022-05-09 (p. 2.1; 3.2) Scope of accreditation No. AB 1776","test_object_zh":"汽车电气与电子设备的部件/组件"},{"_id":"6a5dc9a9f1c10c8ce8259e99","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Pomiar rezystancji, spadku napięcia i ciągłości obwodu","methodology_en":"Measurement of resistance, voltage drop and circuit continuity","parameters":[{"name":"Napięcie","range":"0,01 mV - 100 V"},{"name":"Natężenie","range":"do 250 A"},{"name":"Metoda miliwoltowa"},{"name":"Metoda prądowa"},{"name":"Monitorowanie mikro-przerw"}],"parameters_en":[{"name":"Voltage","range":"0,01 mV - 100 V"},{"name":"Intensity","range":"do 250 A"},{"name":"Millivolt method"},{"name":"Current method"},{"name":"Monitoring of micro-interruptions"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pomiar rezystancji, spadku napięcia i ciągłości obwodu\nZakres:\nNapięcie 0,01 mV - 100 V\nNatężenie do 250 A\nMetoda miliwoltowa\nMetoda prądowa\nMonitorowanie mikro-przerw","reference":"IEC 60512-2-1:2002 | IEC 60512-2-2:2003 VW 75174:2018-10 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0; P 0.2; P 0.2.1; P 0.2.2; P 14.0) LV 214:2010-03 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) GS 95006-7-1:2016-03 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) GS 95006-7-1:2021-11 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) MBN 10384:2010-11 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) SAE/USCAR-2:2020-02 (p. 5.1.9; 5.3.1; 5.3.2) SAE/USCAR-2:2022-06 (p. 5.1.9, 5.3.1, 5.3.2) SAE/USCAR-2:2024-12 (p. 5.1.9, 5.3.1, 5.3.2) SAE/USCAR-21:2020-01 (p. 4.5.2; 4.5.3; 4.5.6) VW 80302:2013-03 (p. E 0.2.3) VW 80332:2017-09 (p. E 0.2.3) VW 80332:2019-01 (p. E 0.2.3) VW 80332:2021-02 (p. E 0.2.3) VW 80332:2024-01 (TG 0) (?) MBN LV 215:2017-08 (p. E 0.2.3) A 009 000 04 99:2013-07 (p. 3.8) VW 60307:2019-11 (p.7.2.2)","norm_bases":["IEC 60512-2-1:2002","IEC 60512-2-2:2003 VW 75174:2018-10 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0; P 0.2; P 0.2.1; P 0.2.2; P 14.0) LV 214:2010-03 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) GS 95006-7-1:2016-03 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) GS 95006-7-1:2021-11 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) MBN 10384:2010-11 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) SAE/USCAR-2:2020-02 (p. 5.1.9; 5.3.1; 5.3.2) SAE/USCAR-2:2022-06 (p. 5.1.9, 5.3.1, 5.3.2) SAE/USCAR-2:2024-12 (p. 5.1.9, 5.3.1, 5.3.2) SAE/USCAR-21:2020-01 (p. 4.5.2; 4.5.3; 4.5.6) VW 80302:2013-03 (p. E 0.2.3) VW 80332:2017-09 (p. E 0.2.3) VW 80332:2019-01 (p. E 0.2.3) VW 80332:2021-02 (p. E 0.2.3) VW 80332:2024-01 (TG 0) (?) MBN LV 215:2017-08 (p. E 0.2.3) A 009 000 04 99:2013-07 (p. 3.8) VW 60307:2019-11 (p.7.2.2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Pomiar rezystancji, spadku napięcia i ciągłości obwodu\nZakres:\nNapięcie 0,01 mV - 100 V\nNatężenie do 250 A\nMetoda miliwoltowa\nMetoda prądowa\nMonitorowanie mikro-przerw IEC 60512-2-1:2002 | IEC 60512-2-2:2003 VW 75174:2018-10 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0; P 0.2; P 0.2.1; P 0.2.2; P 14.0) LV 214:2010-03 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) GS 95006-7-1:2016-03 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) GS 95006-7-1:2021-11 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) MBN 10384:2010-11 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) SAE/USCAR-2:2020-02 (p. 5.1.9; 5.3.1; 5.3.2) SAE/USCAR-2:2022-06 (p. 5.1.9, 5.3.1, 5.3.2) SAE/USCAR-2:2024-12 (p. 5.1.9, 5.3.1, 5.3.2) SAE/USCAR-21:2020-01 (p. 4.5.2; 4.5.3; 4.5.6) VW 80302:2013-03 (p. E 0.2.3) VW 80332:2017-09 (p. E 0.2.3) VW 80332:2019-01 (p. E 0.2.3) VW 80332:2021-02 (p. E 0.2.3) VW 80332:2024-01 (TG 0) (?) MBN LV 215:2017-08 (p. E 0.2.3) A 009 000 04 99:2013-07 (p. 3.8) VW 60307:2019-11 (p.7.2.2) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Pomiar rezystancji, spadku napiecia i ciaglosci obwodu\nZakres:\nNapiecie 0,01 mV - 100 V\nNatezenie do 250 A\nMetoda miliwoltowa\nMetoda pradowa\nMonitorowanie mikro-przerw IEC 60512-2-1:2002 | IEC 60512-2-2:2003 VW 75174:2018-10 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0; P 0.2; P 0.2.1; P 0.2.2; P 14.0) LV 214:2010-03 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) GS 95006-7-1:2016-03 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) GS 95006-7-1:2021-11 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) MBN 10384:2010-11 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) SAE/USCAR-2:2020-02 (p. 5.1.9; 5.3.1; 5.3.2) SAE/USCAR-2:2022-06 (p. 5.1.9, 5.3.1, 5.3.2) SAE/USCAR-2:2024-12 (p. 5.1.9, 5.3.1, 5.3.2) SAE/USCAR-21:2020-01 (p. 4.5.2; 4.5.3; 4.5.6) VW 80302:2013-03 (p. E 0.2.3) VW 80332:2017-09 (p. E 0.2.3) VW 80332:2019-01 (p. E 0.2.3) VW 80332:2021-02 (p. E 0.2.3) VW 80332:2024-01 (TG 0) (?) MBN LV 215:2017-08 (p. E 0.2.3) A 009 000 04 99:2013-07 (p. 3.8) VW 60307:2019-11 (p.7.2.2)","categories":["electronics"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Measurement of resistance, voltage drop and circuit continuity Voltage Intensity Millivolt method Current method Monitoring of micro-interruptions IEC 60512-2-1:2002 | IEC 60512-2-2:2003 VW 75174:2018-10 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0; P 0.2; P 0.2.1; P 0.2.2; P 14.0) LV 214:2010-03 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) GS 95006-7-1:2016-03 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) GS 95006-7-1:2021-11 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) MBN 10384:2010-11 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) SAE/USCAR-2:2020-02 (p. 5.1.9; 5.3.1; 5.3.2) SAE/USCAR-2:2022-06 (p. 5.1.9, 5.3.1, 5.3.2) SAE/USCAR-2:2024-12 (p. 5.1.9, 5.3.1, 5.3.2) SAE/USCAR-21:2020-01 (p. 4.5.2; 4.5.3; 4.5.6) VW 80302:2013-03 (p. E 0.2.3) VW 80332:2017-09 (p. E 0.2.3) VW 80332:2019-01 (p. E 0.2.3) VW 80332:2021-02 (p. E 0.2.3) VW 80332:2024-01 (TG 0) (?) MBN LV 215:2017-08 (p. E 0.2.3) A 009 000 04 99:2013-07 (p. 3.8) VW 60307:2019-11 (p.7.2.2)","search_zh":"汽车电气与电子设备的部件/组件 电压 IEC 60512-2-1:2002 | IEC 60512-2-2:2003 VW 75174:2018-10 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0; P 0.2; P 0.2.1; P 0.2.2; P 14.0) LV 214:2010-03 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) GS 95006-7-1:2016-03 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) GS 95006-7-1:2021-11 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) MBN 10384:2010-11 (p. E 0.2; E 0.2.1; E 0.2.2; E 14.0) SAE/USCAR-2:2020-02 (p. 5.1.9; 5.3.1; 5.3.2) SAE/USCAR-2:2022-06 (p. 5.1.9, 5.3.1, 5.3.2) SAE/USCAR-2:2024-12 (p. 5.1.9, 5.3.1, 5.3.2) SAE/USCAR-21:2020-01 (p. 4.5.2; 4.5.3; 4.5.6) VW 80302:2013-03 (p. E 0.2.3) VW 80332:2017-09 (p. E 0.2.3) VW 80332:2019-01 (p. E 0.2.3) VW 80332:2021-02 (p. E 0.2.3) VW 80332:2024-01 (TG 0) (?) MBN LV 215:2017-08 (p. E 0.2.3) A 009 000 04 99:2013-07 (p. 3.8) VW 60307:2019-11 (p.7.2.2)","test_object_zh":"汽车电气与电子设备的部件/组件","parameters_zh":[{"name":"电压","range":"0,01 mV - 100 V"},{"name":"Natężenie","range":"do 250 A"},{"name":"Metoda miliwoltowa"},{"name":"Metoda prądowa"},{"name":"Monitorowanie mikro-przerw"}]},{"_id":"6a5dc9a9f1c10c8ce8259e9a","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Pomiar rezystancji izolacji i wytrzymałości dielektrycznej","methodology_en":"Measurement of insulation resistance and dielectric strength","parameters":[{"name":"Rezystancja","range":"2 kΩ - 998 GΩ"},{"name":"Napięcie","range":"(1 - 2500) V"},{"name":"Zakres (dotyczy obiektów do badań typu zgrzewy USW):"},{"name":"Rezystancja","range":"2 kΩ - 998 GΩ"},{"name":"Napięcie","range":"(1 - 1000) V"}],"parameters_en":[{"name":"Resistance","range":"2 kΩ - 998 GΩ"},{"name":"Voltage","range":"(1 - 2500) V"},{"name":"Range (applies to test objects of the USW weld type):"},{"name":"Resistance","range":"2 kΩ - 998 GΩ"},{"name":"Voltage","range":"(1 - 1000) V"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pomiar rezystancji izolacji i wytrzymałości dielektrycznej\nZakres:\nRezystancja 2 kΩ - 998 GΩ\nNapięcie (1 - 2500) V\nZakres (dotyczy obiektów do badań typu zgrzewy USW):\nRezystancja 2 kΩ - 998 GΩ\nNapięcie (1 - 1000) V","reference":"IEC 60512-3-1:2002 | IEC 60664-1:2020 (p. 6.8) | ISO 8092-2:2005-12-01 (4.12) | ISO 8092-2:2023-09 (6.4) | ISO 19072-2:2019-12 (p. 4.10) VW 75174:2018-10 (p. E 0.3; P 0.3) LV 214:2010-03 (p. E 0.3) GS 95006-7-1:2016-03 (p. E 0.3) GS 95006-7-1:2021-11 (p. E 0.3) MBN 10384:2010-11 (p. E 0.3) SAE/USCAR-2:2020-02 (p. 5.5.1) SAE/USCAR-2:2022-06 (p. 5.5.1) SAE/USCAR-2:2024-12 (p. 5.5.1) SAE/USCAR-37:2008-08 (p. 5.5.1; 5.5.2) VW 80302:2013-03 (p. E 0.3; E 0.4) VW 80332:2017-09 (p. E 0.3; E 0.4) VW 80332:2019-01 (p. E 0.3; E 0.4) VW 80332:2021-02 (p. E 0.3; E 0.4) VW 80332:2024-01 (TG 0) A 009 000 04 99:2013-07 (p. 3.10) MBN LV 215:2017-08 (p. E 0.3; E 0.4) Scope of accreditation No. AB 1776","norm_bases":["IEC 60512-3-1:2002","IEC 60664-1:2020 (p. 6.8)","ISO 8092-2:2005-12-01 (4.12)","ISO 8092-2:2023-09 (6.4)","ISO 19072-2:2019-12 (p. 4.10) VW 75174:2018-10 (p. E 0.3; P 0.3) LV 214:2010-03 (p. E 0.3) GS 95006-7-1:2016-03 (p. E 0.3) GS 95006-7-1:2021-11 (p. E 0.3) MBN 10384:2010-11 (p. E 0.3) SAE/USCAR-2:2020-02 (p. 5.5.1) SAE/USCAR-2:2022-06 (p. 5.5.1) SAE/USCAR-2:2024-12 (p. 5.5.1) SAE/USCAR-37:2008-08 (p. 5.5.1; 5.5.2) VW 80302:2013-03 (p. E 0.3; E 0.4) VW 80332:2017-09 (p. E 0.3; E 0.4) VW 80332:2019-01 (p. E 0.3; E 0.4) VW 80332:2021-02 (p. E 0.3; E 0.4) VW 80332:2024-01 (TG 0) A 009 000 04 99:2013-07 (p. 3.10) MBN LV 215:2017-08 (p. E 0.3; E 0.4) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Pomiar rezystancji izolacji i wytrzymałości dielektrycznej\nZakres:\nRezystancja 2 kΩ - 998 GΩ\nNapięcie (1 - 2500) V\nZakres (dotyczy obiektów do badań typu zgrzewy USW):\nRezystancja 2 kΩ - 998 GΩ\nNapięcie (1 - 1000) V IEC 60512-3-1:2002 | IEC 60664-1:2020 (p. 6.8) | ISO 8092-2:2005-12-01 (4.12) | ISO 8092-2:2023-09 (6.4) | ISO 19072-2:2019-12 (p. 4.10) VW 75174:2018-10 (p. E 0.3; P 0.3) LV 214:2010-03 (p. E 0.3) GS 95006-7-1:2016-03 (p. E 0.3) GS 95006-7-1:2021-11 (p. E 0.3) MBN 10384:2010-11 (p. E 0.3) SAE/USCAR-2:2020-02 (p. 5.5.1) SAE/USCAR-2:2022-06 (p. 5.5.1) SAE/USCAR-2:2024-12 (p. 5.5.1) SAE/USCAR-37:2008-08 (p. 5.5.1; 5.5.2) VW 80302:2013-03 (p. E 0.3; E 0.4) VW 80332:2017-09 (p. E 0.3; E 0.4) VW 80332:2019-01 (p. E 0.3; E 0.4) VW 80332:2021-02 (p. E 0.3; E 0.4) VW 80332:2024-01 (TG 0) A 009 000 04 99:2013-07 (p. 3.10) MBN LV 215:2017-08 (p. E 0.3; E 0.4) Scope of accreditation No. AB 1776 Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Pomiar rezystancji izolacji i wytrzymalosci dielektrycznej\nZakres:\nRezystancja 2 kΩ - 998 GΩ\nNapiecie (1 - 2500) V\nZakres (dotyczy obiektow do badan typu zgrzewy USW):\nRezystancja 2 kΩ - 998 GΩ\nNapiecie (1 - 1000) V IEC 60512-3-1:2002 | IEC 60664-1:2020 (p. 6.8) | ISO 8092-2:2005-12-01 (4.12) | ISO 8092-2:2023-09 (6.4) | ISO 19072-2:2019-12 (p. 4.10) VW 75174:2018-10 (p. E 0.3; P 0.3) LV 214:2010-03 (p. E 0.3) GS 95006-7-1:2016-03 (p. E 0.3) GS 95006-7-1:2021-11 (p. E 0.3) MBN 10384:2010-11 (p. E 0.3) SAE/USCAR-2:2020-02 (p. 5.5.1) SAE/USCAR-2:2022-06 (p. 5.5.1) SAE/USCAR-2:2024-12 (p. 5.5.1) SAE/USCAR-37:2008-08 (p. 5.5.1; 5.5.2) VW 80302:2013-03 (p. E 0.3; E 0.4) VW 80332:2017-09 (p. E 0.3; E 0.4) VW 80332:2019-01 (p. E 0.3; E 0.4) VW 80332:2021-02 (p. E 0.3; E 0.4) VW 80332:2024-01 (TG 0) A 009 000 04 99:2013-07 (p. 3.10) MBN LV 215:2017-08 (p. E 0.3; E 0.4) Scope of accreditation No. AB 1776","categories":["construction","electronics"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Measurement of insulation resistance and dielectric strength Resistance Voltage Range (applies to test objects of the USW weld type): Resistance Voltage IEC 60512-3-1:2002 | IEC 60664-1:2020 (p. 6.8) | ISO 8092-2:2005-12-01 (4.12) | ISO 8092-2:2023-09 (6.4) | ISO 19072-2:2019-12 (p. 4.10) VW 75174:2018-10 (p. E 0.3; P 0.3) LV 214:2010-03 (p. E 0.3) GS 95006-7-1:2016-03 (p. E 0.3) GS 95006-7-1:2021-11 (p. E 0.3) MBN 10384:2010-11 (p. E 0.3) SAE/USCAR-2:2020-02 (p. 5.5.1) SAE/USCAR-2:2022-06 (p. 5.5.1) SAE/USCAR-2:2024-12 (p. 5.5.1) SAE/USCAR-37:2008-08 (p. 5.5.1; 5.5.2) VW 80302:2013-03 (p. E 0.3; E 0.4) VW 80332:2017-09 (p. E 0.3; E 0.4) VW 80332:2019-01 (p. E 0.3; E 0.4) VW 80332:2021-02 (p. E 0.3; E 0.4) VW 80332:2024-01 (TG 0) A 009 000 04 99:2013-07 (p. 3.10) MBN LV 215:2017-08 (p. E 0.3; E 0.4) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"电阻","range":"2 kΩ - 998 GΩ"},{"name":"电压","range":"(1 - 2500) V"},{"name":"Zakres (dotyczy obiektów do badań typu zgrzewy USW):"},{"name":"电阻","range":"2 kΩ - 998 GΩ"},{"name":"电压","range":"(1 - 1000) V"}],"search_zh":"汽车电气与电子设备的部件/组件 电阻 电压 电阻 电压 IEC 60512-3-1:2002 | IEC 60664-1:2020 (p. 6.8) | ISO 8092-2:2005-12-01 (4.12) | ISO 8092-2:2023-09 (6.4) | ISO 19072-2:2019-12 (p. 4.10) VW 75174:2018-10 (p. E 0.3; P 0.3) LV 214:2010-03 (p. E 0.3) GS 95006-7-1:2016-03 (p. E 0.3) GS 95006-7-1:2021-11 (p. E 0.3) MBN 10384:2010-11 (p. E 0.3) SAE/USCAR-2:2020-02 (p. 5.5.1) SAE/USCAR-2:2022-06 (p. 5.5.1) SAE/USCAR-2:2024-12 (p. 5.5.1) SAE/USCAR-37:2008-08 (p. 5.5.1; 5.5.2) VW 80302:2013-03 (p. E 0.3; E 0.4) VW 80332:2017-09 (p. E 0.3; E 0.4) VW 80332:2019-01 (p. E 0.3; E 0.4) VW 80332:2021-02 (p. E 0.3; E 0.4) VW 80332:2024-01 (TG 0) A 009 000 04 99:2013-07 (p. 3.10) MBN LV 215:2017-08 (p. E 0.3; E 0.4) Scope of accreditation No. AB 1776","test_object_zh":"汽车电气与电子设备的部件/组件"},{"_id":"6a5dc9a9f1c10c8ce8259e9b","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Pomiar długości","methodology_en":"Length measurement","parameters":[{"name":"Zakres","range":"(0,2 - 250) mm"},{"name":"Length measurement"},{"name":"Range","range":"(0,2 - 250) mm"}],"parameters_en":[{"name":"Range","range":"(0,2 - 250) mm"},{"name":"Length measurement"},{"name":"Range","range":"(0,2 - 250) mm"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pomiar długości\nZakres:\nZakres (0,2 - 250) mm\nLength measurement\nRange (0,2 - 250) mm","reference":"IEC 60512-1-2:2002 VW 75174:2018-10 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1; P 1.1; P 1.2; P 5.1; P 14.2; P 4.1) VW 80332:2024-01 (TG 1, TG 4) LV 214:2010-03 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) GS 95006-7-1:2016-03 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) GS 95006-7-1:2021-11 (p. E 1.1; E 1.2; E 4.1; E 5.1; E 14.2) MBN 10384:2010-11 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) A 009 000 04 99:2013-07 (p. 3.2)","norm_bases":["IEC 60512-1-2:2002 VW 75174:2018-10 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1; P 1.1; P 1.2; P 5.1; P 14.2; P 4.1) VW 80332:2024-01 (TG 1, TG 4) LV 214:2010-03 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) GS 95006-7-1:2016-03 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) GS 95006-7-1:2021-11 (p. E 1.1; E 1.2; E 4.1; E 5.1; E 14.2) MBN 10384:2010-11 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) A 009 000 04 99:2013-07 (p. 3.2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Pomiar długości\nZakres:\nZakres (0,2 - 250) mm\nLength measurement\nRange (0,2 - 250) mm IEC 60512-1-2:2002 VW 75174:2018-10 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1; P 1.1; P 1.2; P 5.1; P 14.2; P 4.1) VW 80332:2024-01 (TG 1, TG 4) LV 214:2010-03 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) GS 95006-7-1:2016-03 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) GS 95006-7-1:2021-11 (p. E 1.1; E 1.2; E 4.1; E 5.1; E 14.2) MBN 10384:2010-11 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) A 009 000 04 99:2013-07 (p. 3.2) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Pomiar dlugosci\nZakres:\nZakres (0,2 - 250) mm\nLength measurement\nRange (0,2 - 250) mm IEC 60512-1-2:2002 VW 75174:2018-10 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1; P 1.1; P 1.2; P 5.1; P 14.2; P 4.1) VW 80332:2024-01 (TG 1, TG 4) LV 214:2010-03 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) GS 95006-7-1:2016-03 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) GS 95006-7-1:2021-11 (p. E 1.1; E 1.2; E 4.1; E 5.1; E 14.2) MBN 10384:2010-11 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) A 009 000 04 99:2013-07 (p. 3.2)","categories":["electronics"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Length measurement Range Length measurement Range IEC 60512-1-2:2002 VW 75174:2018-10 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1; P 1.1; P 1.2; P 5.1; P 14.2; P 4.1) VW 80332:2024-01 (TG 1, TG 4) LV 214:2010-03 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) GS 95006-7-1:2016-03 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) GS 95006-7-1:2021-11 (p. E 1.1; E 1.2; E 4.1; E 5.1; E 14.2) MBN 10384:2010-11 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) A 009 000 04 99:2013-07 (p. 3.2)","parameters_zh":[{"name":"范围","range":"(0,2 - 250) mm"},{"name":"Length measurement"},{"name":"范围","range":"(0,2 - 250) mm"}],"search_zh":"汽车电气与电子设备的部件/组件 范围 范围 IEC 60512-1-2:2002 VW 75174:2018-10 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1; P 1.1; P 1.2; P 5.1; P 14.2; P 4.1) VW 80332:2024-01 (TG 1, TG 4) LV 214:2010-03 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) GS 95006-7-1:2016-03 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) GS 95006-7-1:2021-11 (p. E 1.1; E 1.2; E 4.1; E 5.1; E 14.2) MBN 10384:2010-11 (p. E 1.1; E 1.2; E 5.1; E 14.2; E 4.1) A 009 000 04 99:2013-07 (p. 3.2)","test_object_zh":"汽车电气与电子设备的部件/组件"},{"_id":"6a5dc9a9f1c10c8ce8259e9c","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Weryfikacja oznaczeń na powierzchni terminali i tworzyw sztucznych oraz ocena wizualna","methodology_en":"Verification of markings on the surface of terminals and plastics and visual assessment","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Weryfikacja oznaczeń na powierzchni terminali i tworzyw sztucznych oraz ocena wizualna","reference":"VW 75174:2018-10 (TG 2; TG 3) VW 80332:2024-01 (TG 2; TG 3) LV 214:2010-03 (PG 2, PG 3) GS 95006-7-1:2016-03 (PG 2; PG 3) GS 95006-7-1:2021-11 (PG 2; PG 3) MBN 10384:2010-11 (PG 2; PG 3)","norm_bases":["VW 75174:2018-10 (TG 2; TG 3) VW 80332:2024-01 (TG 2; TG 3) LV 214:2010-03 (PG 2, PG 3) GS 95006-7-1:2016-03 (PG 2; PG 3) GS 95006-7-1:2021-11 (PG 2; PG 3) MBN 10384:2010-11 (PG 2; PG 3)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Weryfikacja oznaczeń na powierzchni terminali i tworzyw sztucznych oraz ocena wizualna VW 75174:2018-10 (TG 2; TG 3) VW 80332:2024-01 (TG 2; TG 3) LV 214:2010-03 (PG 2, PG 3) GS 95006-7-1:2016-03 (PG 2; PG 3) GS 95006-7-1:2021-11 (PG 2; PG 3) MBN 10384:2010-11 (PG 2; PG 3) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Weryfikacja oznaczen na powierzchni terminali i tworzyw sztucznych oraz ocena wizualna VW 75174:2018-10 (TG 2; TG 3) VW 80332:2024-01 (TG 2; TG 3) LV 214:2010-03 (PG 2, PG 3) GS 95006-7-1:2016-03 (PG 2; PG 3) GS 95006-7-1:2021-11 (PG 2; PG 3) MBN 10384:2010-11 (PG 2; PG 3)","categories":["electronics"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Verification of markings on the surface of terminals and plastics and visual assessment VW 75174:2018-10 (TG 2; TG 3) VW 80332:2024-01 (TG 2; TG 3) LV 214:2010-03 (PG 2, PG 3) GS 95006-7-1:2016-03 (PG 2; PG 3) GS 95006-7-1:2021-11 (PG 2; PG 3) MBN 10384:2010-11 (PG 2; PG 3)","search_zh":"汽车电气与电子设备的部件/组件 VW 75174:2018-10 (TG 2; TG 3) VW 80332:2024-01 (TG 2; TG 3) LV 214:2010-03 (PG 2, PG 3) GS 95006-7-1:2016-03 (PG 2; PG 3) GS 95006-7-1:2021-11 (PG 2; PG 3) MBN 10384:2010-11 (PG 2; PG 3)","test_object_zh":"汽车电气与电子设备的部件/组件"},{"_id":"6a5dc9a9f1c10c8ce8259e9d","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów oraz materiały do ich wytwarzania","test_object_en":"Components/assemblies of automotive electrical and electronic equipment and materials for their manufacture","methodology":"Pomiar grubości powłoki","methodology_en":"Coating thickness measurement","parameters":[{"name":"Coating thickness measurement"}],"parameters_en":[{"name":"Coating thickness measurement"}],"technique":"Metoda fluorescencji rentgenowskiej","techniques":["Metoda fluorescencji rentgenowskiej"],"technique_en":"X-ray fluorescence method","computed":[],"computed_en":[],"activity":"Pomiar grubości powłoki\nCoating thickness measurement\nMetoda fluorescencji rentgenowskiej","reference":"EN ISO 3497:2000 | PN-EN ISO 3497:2004","norm_bases":["EN ISO 3497:2000","PN-EN ISO 3497:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów oraz materiały do ich wytwarzania Pomiar grubości powłoki\nCoating thickness measurement\nMetoda fluorescencji rentgenowskiej EN ISO 3497:2000 | PN-EN ISO 3497:2004 Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow oraz materialy do ich wytwarzania Pomiar grubosci powloki\nCoating thickness measurement\nMetoda fluorescencji rentgenowskiej EN ISO 3497:2000 | PN-EN ISO 3497:2004","categories":["materials","electronics"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment and materials for their manufacture Coating thickness measurement X-ray fluorescence method Coating thickness measurement EN ISO 3497:2000 | PN-EN ISO 3497:2004"},{"_id":"6a5dc9a9f1c10c8ce8259e9e","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów oraz materiały do ich wytwarzania","test_object_en":"Components/assemblies of automotive electrical and electronic equipment and materials for their manufacture","methodology":"Morfologia powierzchni i mikrostruktura.","methodology_en":"Surface morphology and microstructure.","parameters":[],"parameters_en":[],"technique":"Metoda skaningowej mikroskopii elektronowej z jakościową analizą składu chemicznego w mikroobszarach (SEM/EDS)","techniques":["Metoda skaningowej mikroskopii elektronowej z jakościową analizą składu chemicznego w mikroobszarach (SEM/EDS)"],"technique_en":"Scanning electron microscopy method with qualitative analysis of chemical composition in microareas (SEM/EDS)","computed":[],"computed_en":[],"activity":"Morfologia powierzchni i mikrostruktura.\nMetoda skaningowej mikroskopii elektronowej z jakościową analizą składu chemicznego w mikroobszarach (SEM/EDS)","reference":"EAEP_4-4_PE-TCK_01-01-A62_PL wyd 2 z dnia 19.12.2025 * Scope of accreditation No. AB 1776","norm_bases":["EAEP_4-4_PE-TCK_01-01-A62_PL wyd 2 z dnia 19.12.2025 * Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów oraz materiały do ich wytwarzania Morfologia powierzchni i mikrostruktura.\nMetoda skaningowej mikroskopii elektronowej z jakościową analizą składu chemicznego w mikroobszarach (SEM/EDS) EAEP_4-4_PE-TCK_01-01-A62_PL wyd 2 z dnia 19.12.2025 * Scope of accreditation No. AB 1776 Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow oraz materialy do ich wytwarzania Morfologia powierzchni i mikrostruktura.\nMetoda skaningowej mikroskopii elektronowej z jakosciowa analiza skladu chemicznego w mikroobszarach (SEM/EDS) EAEP_4-4_PE-TCK_01-01-A62_PL wyd 2 z dnia 19.12.2025 * Scope of accreditation No. AB 1776","categories":["materials","electronics"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment and materials for their manufacture Surface morphology and microstructure. Scanning electron microscopy method with qualitative analysis of chemical composition in microareas (SEM/EDS) EAEP_4-4_PE-TCK_01-01-A62_PL wyd 2 z dnia 19.12.2025 * Scope of accreditation No. AB 1776"},{"_id":"6a5dc9a9f1c10c8ce8259e9f","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Odporność na działanie temperatur","methodology_en":"Resistance to the action of temperatures","parameters":[{"name":"Zakres","range":"(-40 - 200) °C (± 2 °C)"},{"name":"starzenie w suchym gorącu"},{"name":"Zakres","range":"(80 - 200) °C"}],"parameters_en":[{"name":"Range","range":"(-40 - 200) °C (± 2 °C)"},{"name":"ageing in dry heat"},{"name":"Range","range":"(80 - 200) °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie temperatur\nZakres:\nZakres (-40 - 200) °C (± 2 °C)\nstarzenie w suchym gorącu\nZakres (80 - 200) °C","reference":"IEC 60068-2-2:2007 | IEC 60068-2-1:2007 VW 75174:2018-10 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 31.1; B 28.1; B 20.3; L 5.3; L 19.3; L 20.1; L 20.5; L 21.1; L 31.1; L 28.1; L 20.3) LV 214:2010-03 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) GS 95006-7-1:2016-03 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) GS 95006-7-1:2021-11 (p. B 5.3; B 19.3; B 20.1; B 20.3; B 20.5; B 21.1; B 28.1) MBN 10384:2010-11 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) VW 50554 – 2 SAE/USCAR-2:2020-02 (p. 5.6.3) SAE/USCAR-2:2022-06 (p. 5.6.3) SAE/USCAR-2:2024-12 (p. 5.6.3) VW 80332:2017-09 (PG 21) VW 80332:2019-01 (PG 21) VW 80332:2021-02 (PG 21) VW 80332:2024-01 (TG 20; TG 21) MBN LV 215:2017-08 (PG 21) A 009 000 04 99:2013-07 (p. 3.10; B 19.3) VW 60307:2019-11 (p. 7.2.5)","norm_bases":["IEC 60068-2-2:2007","IEC 60068-2-1:2007 VW 75174:2018-10 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 31.1; B 28.1; B 20.3; L 5.3; L 19.3; L 20.1; L 20.5; L 21.1; L 31.1; L 28.1; L 20.3) LV 214:2010-03 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) GS 95006-7-1:2016-03 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) GS 95006-7-1:2021-11 (p. B 5.3; B 19.3; B 20.1; B 20.3; B 20.5; B 21.1; B 28.1) MBN 10384:2010-11 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) VW 50554 – 2 SAE/USCAR-2:2020-02 (p. 5.6.3) SAE/USCAR-2:2022-06 (p. 5.6.3) SAE/USCAR-2:2024-12 (p. 5.6.3) VW 80332:2017-09 (PG 21) VW 80332:2019-01 (PG 21) VW 80332:2021-02 (PG 21) VW 80332:2024-01 (TG 20; TG 21) MBN LV 215:2017-08 (PG 21) A 009 000 04 99:2013-07 (p. 3.10; B 19.3) VW 60307:2019-11 (p. 7.2.5)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Odporność na działanie temperatur\nZakres:\nZakres (-40 - 200) °C (± 2 °C)\nstarzenie w suchym gorącu\nZakres (80 - 200) °C IEC 60068-2-2:2007 | IEC 60068-2-1:2007 VW 75174:2018-10 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 31.1; B 28.1; B 20.3; L 5.3; L 19.3; L 20.1; L 20.5; L 21.1; L 31.1; L 28.1; L 20.3) LV 214:2010-03 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) GS 95006-7-1:2016-03 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) GS 95006-7-1:2021-11 (p. B 5.3; B 19.3; B 20.1; B 20.3; B 20.5; B 21.1; B 28.1) MBN 10384:2010-11 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) VW 50554 – 2 SAE/USCAR-2:2020-02 (p. 5.6.3) SAE/USCAR-2:2022-06 (p. 5.6.3) SAE/USCAR-2:2024-12 (p. 5.6.3) VW 80332:2017-09 (PG 21) VW 80332:2019-01 (PG 21) VW 80332:2021-02 (PG 21) VW 80332:2024-01 (TG 20; TG 21) MBN LV 215:2017-08 (PG 21) A 009 000 04 99:2013-07 (p. 3.10; B 19.3) VW 60307:2019-11 (p. 7.2.5) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Odpornosc na dzialanie temperatur\nZakres:\nZakres (-40 - 200) °C (± 2 °C)\nstarzenie w suchym goracu\nZakres (80 - 200) °C IEC 60068-2-2:2007 | IEC 60068-2-1:2007 VW 75174:2018-10 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 31.1; B 28.1; B 20.3; L 5.3; L 19.3; L 20.1; L 20.5; L 21.1; L 31.1; L 28.1; L 20.3) LV 214:2010-03 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) GS 95006-7-1:2016-03 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) GS 95006-7-1:2021-11 (p. B 5.3; B 19.3; B 20.1; B 20.3; B 20.5; B 21.1; B 28.1) MBN 10384:2010-11 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) VW 50554 – 2 SAE/USCAR-2:2020-02 (p. 5.6.3) SAE/USCAR-2:2022-06 (p. 5.6.3) SAE/USCAR-2:2024-12 (p. 5.6.3) VW 80332:2017-09 (PG 21) VW 80332:2019-01 (PG 21) VW 80332:2021-02 (PG 21) VW 80332:2024-01 (TG 20; TG 21) MBN LV 215:2017-08 (PG 21) A 009 000 04 99:2013-07 (p. 3.10; B 19.3) VW 60307:2019-11 (p. 7.2.5)","categories":["electronics"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Resistance to the action of temperatures Range ageing in dry heat Range IEC 60068-2-2:2007 | IEC 60068-2-1:2007 VW 75174:2018-10 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 31.1; B 28.1; B 20.3; L 5.3; L 19.3; L 20.1; L 20.5; L 21.1; L 31.1; L 28.1; L 20.3) LV 214:2010-03 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) GS 95006-7-1:2016-03 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) GS 95006-7-1:2021-11 (p. B 5.3; B 19.3; B 20.1; B 20.3; B 20.5; B 21.1; B 28.1) MBN 10384:2010-11 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) VW 50554 – 2 SAE/USCAR-2:2020-02 (p. 5.6.3) SAE/USCAR-2:2022-06 (p. 5.6.3) SAE/USCAR-2:2024-12 (p. 5.6.3) VW 80332:2017-09 (PG 21) VW 80332:2019-01 (PG 21) VW 80332:2021-02 (PG 21) VW 80332:2024-01 (TG 20; TG 21) MBN LV 215:2017-08 (PG 21) A 009 000 04 99:2013-07 (p. 3.10; B 19.3) VW 60307:2019-11 (p. 7.2.5)","parameters_zh":[{"name":"范围","range":"(-40 - 200) °C (± 2 °C)"},{"name":"starzenie w suchym gorącu"},{"name":"范围","range":"(80 - 200) °C"}],"search_zh":"汽车电气与电子设备的部件/组件 范围 范围 IEC 60068-2-2:2007 | IEC 60068-2-1:2007 VW 75174:2018-10 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 31.1; B 28.1; B 20.3; L 5.3; L 19.3; L 20.1; L 20.5; L 21.1; L 31.1; L 28.1; L 20.3) LV 214:2010-03 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) GS 95006-7-1:2016-03 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) GS 95006-7-1:2021-11 (p. B 5.3; B 19.3; B 20.1; B 20.3; B 20.5; B 21.1; B 28.1) MBN 10384:2010-11 (p. B 5.3; B 19.3; B 20.1; B 20.5; B 21.1; B 28.1; B 20.3) VW 50554 – 2 SAE/USCAR-2:2020-02 (p. 5.6.3) SAE/USCAR-2:2022-06 (p. 5.6.3) SAE/USCAR-2:2024-12 (p. 5.6.3) VW 80332:2017-09 (PG 21) VW 80332:2019-01 (PG 21) VW 80332:2021-02 (PG 21) VW 80332:2024-01 (TG 20; TG 21) MBN LV 215:2017-08 (PG 21) A 009 000 04 99:2013-07 (p. 3.10; B 19.3) VW 60307:2019-11 (p. 7.2.5)","test_object_zh":"汽车电气与电子设备的部件/组件"},{"_id":"6a5dc9a9f1c10c8ce8259ea0","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Odporność na działanie temperatury i wilgoci","methodology_en":"Resistance to temperature and humidity","parameters":[{"name":"Temperatura","range":"(23 - 85) °C"},{"name":"Wilgotność","range":"(50 - 95) % RH"}],"parameters_en":[{"name":"Temperature","range":"(23 - 85) °C"},{"name":"Humidity","range":"(50 - 95) % RH"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na działanie temperatury i wilgoci\nZakres:\nTemperatura (23 - 85) °C\nWilgotność (50 - 95) % RH","reference":"IEC 60068-2-30:2005 | IEC 60068-2-78:2012-10 VW 75174:2018-10 (p. B 15.3; B 19.5; B 20.2; L 15.3; L 19.5; L 20.2) LV 214:2010-03 (p. B 15.3, B 19.5, B 20.2) GS 95006-7-1:2016-03 (p. B 15.3, B 19.5, B 20.2) GS 95006-7-1:2021-11 (p. B 15.3; B 19.5; B 20.2) MBN 10384:2010-11 (p. B 15.3, B 19.5, B 20.2) SAE/USCAR-2:2020-02 (p. 5.6.2) SAE/USCAR-2:2022-06 (p. 5.6.2) SAE/USCAR-2:2024-12 (p. 5.6.2) SAE/USCAR-21:2020-01 (p. 4.5.4) Scope of accreditation No. AB 1776","norm_bases":["IEC 60068-2-30:2005","IEC 60068-2-78:2012-10 VW 75174:2018-10 (p. B 15.3; B 19.5; B 20.2; L 15.3; L 19.5; L 20.2) LV 214:2010-03 (p. B 15.3, B 19.5, B 20.2) GS 95006-7-1:2016-03 (p. B 15.3, B 19.5, B 20.2) GS 95006-7-1:2021-11 (p. B 15.3; B 19.5; B 20.2) MBN 10384:2010-11 (p. B 15.3, B 19.5, B 20.2) SAE/USCAR-2:2020-02 (p. 5.6.2) SAE/USCAR-2:2022-06 (p. 5.6.2) SAE/USCAR-2:2024-12 (p. 5.6.2) SAE/USCAR-21:2020-01 (p. 4.5.4) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Odporność na działanie temperatury i wilgoci\nZakres:\nTemperatura (23 - 85) °C\nWilgotność (50 - 95) % RH IEC 60068-2-30:2005 | IEC 60068-2-78:2012-10 VW 75174:2018-10 (p. B 15.3; B 19.5; B 20.2; L 15.3; L 19.5; L 20.2) LV 214:2010-03 (p. B 15.3, B 19.5, B 20.2) GS 95006-7-1:2016-03 (p. B 15.3, B 19.5, B 20.2) GS 95006-7-1:2021-11 (p. B 15.3; B 19.5; B 20.2) MBN 10384:2010-11 (p. B 15.3, B 19.5, B 20.2) SAE/USCAR-2:2020-02 (p. 5.6.2) SAE/USCAR-2:2022-06 (p. 5.6.2) SAE/USCAR-2:2024-12 (p. 5.6.2) SAE/USCAR-21:2020-01 (p. 4.5.4) Scope of accreditation No. AB 1776 Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Odpornosc na dzialanie temperatury i wilgoci\nZakres:\nTemperatura (23 - 85) °C\nWilgotnosc (50 - 95) % RH IEC 60068-2-30:2005 | IEC 60068-2-78:2012-10 VW 75174:2018-10 (p. B 15.3; B 19.5; B 20.2; L 15.3; L 19.5; L 20.2) LV 214:2010-03 (p. B 15.3, B 19.5, B 20.2) GS 95006-7-1:2016-03 (p. B 15.3, B 19.5, B 20.2) GS 95006-7-1:2021-11 (p. B 15.3; B 19.5; B 20.2) MBN 10384:2010-11 (p. B 15.3, B 19.5, B 20.2) SAE/USCAR-2:2020-02 (p. 5.6.2) SAE/USCAR-2:2022-06 (p. 5.6.2) SAE/USCAR-2:2024-12 (p. 5.6.2) SAE/USCAR-21:2020-01 (p. 4.5.4) Scope of accreditation No. AB 1776","categories":["electronics"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Resistance to temperature and humidity Temperature Humidity IEC 60068-2-30:2005 | IEC 60068-2-78:2012-10 VW 75174:2018-10 (p. B 15.3; B 19.5; B 20.2; L 15.3; L 19.5; L 20.2) LV 214:2010-03 (p. B 15.3, B 19.5, B 20.2) GS 95006-7-1:2016-03 (p. B 15.3, B 19.5, B 20.2) GS 95006-7-1:2021-11 (p. B 15.3; B 19.5; B 20.2) MBN 10384:2010-11 (p. B 15.3, B 19.5, B 20.2) SAE/USCAR-2:2020-02 (p. 5.6.2) SAE/USCAR-2:2022-06 (p. 5.6.2) SAE/USCAR-2:2024-12 (p. 5.6.2) SAE/USCAR-21:2020-01 (p. 4.5.4) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"温度","range":"(23 - 85) °C"},{"name":"湿度","range":"(50 - 95) % RH"}],"search_zh":"汽车电气与电子设备的部件/组件 温度 湿度 IEC 60068-2-30:2005 | IEC 60068-2-78:2012-10 VW 75174:2018-10 (p. B 15.3; B 19.5; B 20.2; L 15.3; L 19.5; L 20.2) LV 214:2010-03 (p. B 15.3, B 19.5, B 20.2) GS 95006-7-1:2016-03 (p. B 15.3, B 19.5, B 20.2) GS 95006-7-1:2021-11 (p. B 15.3; B 19.5; B 20.2) MBN 10384:2010-11 (p. B 15.3, B 19.5, B 20.2) SAE/USCAR-2:2020-02 (p. 5.6.2) SAE/USCAR-2:2022-06 (p. 5.6.2) SAE/USCAR-2:2024-12 (p. 5.6.2) SAE/USCAR-21:2020-01 (p. 4.5.4) Scope of accreditation No. AB 1776","test_object_zh":"汽车电气与电子设备的部件/组件"},{"_id":"6a5dc9a9f1c10c8ce8259ea1","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Odporność na cykliczne zmiany temperatury","methodology_en":"Resistance to cyclic temperature changes","parameters":[{"name":"Zakres","range":"(-40 - 175) °C (± 2 °C)"}],"parameters_en":[{"name":"Range","range":"(-40 - 175) °C (± 2 °C)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na cykliczne zmiany temperatury\nZakres (-40 - 175) °C (± 2 °C)","reference":"IEC 60068-2-14:2009 (Test Na, Nb) VW 75174:2018-10 (p. B 19.1; B 19.2; L 19.1; L 19.2) VW 80332:2024-01 (TG 19) LV 214:2010-03 (p. B 19.1; B 19.2) GS 95006-7-1:2016-03 (p. B 19.1; B 19.2) GS 95006-7-1:2021-11 (p. B 19.1; B 19.2) MBN 10384:2010-11 (p. B 19.1; B 19.2) SAE/USCAR-2:2020-02 (p. 5.6.1) SAE/USCAR-2:2022-06 (p. 5.6.1) SAE/USCAR-2:2024-12 (p. 5.6.1) SAE/USCAR-21:2020-01 (p. 4.5.5) A 009 000 04 99:2013-07 (p. 3.10) VW 60307:2019-11 (p. 7.2.3)","norm_bases":["IEC 60068-2-14:2009 (Test Na, Nb) VW 75174:2018-10 (p. B 19.1; B 19.2; L 19.1; L 19.2) VW 80332:2024-01 (TG 19) LV 214:2010-03 (p. B 19.1; B 19.2) GS 95006-7-1:2016-03 (p. B 19.1; B 19.2) GS 95006-7-1:2021-11 (p. B 19.1; B 19.2) MBN 10384:2010-11 (p. B 19.1; B 19.2) SAE/USCAR-2:2020-02 (p. 5.6.1) SAE/USCAR-2:2022-06 (p. 5.6.1) SAE/USCAR-2:2024-12 (p. 5.6.1) SAE/USCAR-21:2020-01 (p. 4.5.5) A 009 000 04 99:2013-07 (p. 3.10) VW 60307:2019-11 (p. 7.2.3)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Odporność na cykliczne zmiany temperatury\nZakres (-40 - 175) °C (± 2 °C) IEC 60068-2-14:2009 (Test Na, Nb) VW 75174:2018-10 (p. B 19.1; B 19.2; L 19.1; L 19.2) VW 80332:2024-01 (TG 19) LV 214:2010-03 (p. B 19.1; B 19.2) GS 95006-7-1:2016-03 (p. B 19.1; B 19.2) GS 95006-7-1:2021-11 (p. B 19.1; B 19.2) MBN 10384:2010-11 (p. B 19.1; B 19.2) SAE/USCAR-2:2020-02 (p. 5.6.1) SAE/USCAR-2:2022-06 (p. 5.6.1) SAE/USCAR-2:2024-12 (p. 5.6.1) SAE/USCAR-21:2020-01 (p. 4.5.5) A 009 000 04 99:2013-07 (p. 3.10) VW 60307:2019-11 (p. 7.2.3) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Odpornosc na cykliczne zmiany temperatury\nZakres (-40 - 175) °C (± 2 °C) IEC 60068-2-14:2009 (Test Na, Nb) VW 75174:2018-10 (p. B 19.1; B 19.2; L 19.1; L 19.2) VW 80332:2024-01 (TG 19) LV 214:2010-03 (p. B 19.1; B 19.2) GS 95006-7-1:2016-03 (p. B 19.1; B 19.2) GS 95006-7-1:2021-11 (p. B 19.1; B 19.2) MBN 10384:2010-11 (p. B 19.1; B 19.2) SAE/USCAR-2:2020-02 (p. 5.6.1) SAE/USCAR-2:2022-06 (p. 5.6.1) SAE/USCAR-2:2024-12 (p. 5.6.1) SAE/USCAR-21:2020-01 (p. 4.5.5) A 009 000 04 99:2013-07 (p. 3.10) VW 60307:2019-11 (p. 7.2.3)","categories":["electronics"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Resistance to cyclic temperature changes Range IEC 60068-2-14:2009 (Test Na, Nb) VW 75174:2018-10 (p. B 19.1; B 19.2; L 19.1; L 19.2) VW 80332:2024-01 (TG 19) LV 214:2010-03 (p. B 19.1; B 19.2) GS 95006-7-1:2016-03 (p. B 19.1; B 19.2) GS 95006-7-1:2021-11 (p. B 19.1; B 19.2) MBN 10384:2010-11 (p. B 19.1; B 19.2) SAE/USCAR-2:2020-02 (p. 5.6.1) SAE/USCAR-2:2022-06 (p. 5.6.1) SAE/USCAR-2:2024-12 (p. 5.6.1) SAE/USCAR-21:2020-01 (p. 4.5.5) A 009 000 04 99:2013-07 (p. 3.10) VW 60307:2019-11 (p. 7.2.3)","parameters_zh":[{"name":"范围","range":"(-40 - 175) °C (± 2 °C)"}],"search_zh":"汽车电气与电子设备的部件/组件 耐温度循环变化性 范围 IEC 60068-2-14:2009 (Test Na, Nb) VW 75174:2018-10 (p. B 19.1; B 19.2; L 19.1; L 19.2) VW 80332:2024-01 (TG 19) LV 214:2010-03 (p. B 19.1; B 19.2) GS 95006-7-1:2016-03 (p. B 19.1; B 19.2) GS 95006-7-1:2021-11 (p. B 19.1; B 19.2) MBN 10384:2010-11 (p. B 19.1; B 19.2) SAE/USCAR-2:2020-02 (p. 5.6.1) SAE/USCAR-2:2022-06 (p. 5.6.1) SAE/USCAR-2:2024-12 (p. 5.6.1) SAE/USCAR-21:2020-01 (p. 4.5.5) A 009 000 04 99:2013-07 (p. 3.10) VW 60307:2019-11 (p. 7.2.3)","test_object_zh":"汽车电气与电子设备的部件/组件","methodology_zh":"耐温度循环变化性"},{"_id":"6a5dc9a9f1c10c8ce8259ea2","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Odporność na uszkodzenia mechaniczne","methodology_en":"Resistance to mechanical damage","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uszkodzenia mechaniczne","reference":"IEC 60068-2-31:2008 VW 75174:2018-10 (TG 6) VW 80332:2024-01 (TG 6) LV 214:2010-03 (PG 6) GS 95006-7-1:2016-03 (PG 6) GS 95006-7-1:2021-11 (PG 6) MBN 10384:2010-11 (PG 6) SAE/USCAR-2:2020-02 (p. 5.4.8) SAE/USCAR-2:2022-06 (p. 5.4.8) SAE/USCAR-2:2024-12 (p. 5.4.8) VW 80302:2013-03 Scope of accreditation No. AB 1776","norm_bases":["IEC 60068-2-31:2008 VW 75174:2018-10 (TG 6) VW 80332:2024-01 (TG 6) LV 214:2010-03 (PG 6) GS 95006-7-1:2016-03 (PG 6) GS 95006-7-1:2021-11 (PG 6) MBN 10384:2010-11 (PG 6) SAE/USCAR-2:2020-02 (p. 5.4.8) SAE/USCAR-2:2022-06 (p. 5.4.8) SAE/USCAR-2:2024-12 (p. 5.4.8) VW 80302:2013-03 Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Odporność na uszkodzenia mechaniczne IEC 60068-2-31:2008 VW 75174:2018-10 (TG 6) VW 80332:2024-01 (TG 6) LV 214:2010-03 (PG 6) GS 95006-7-1:2016-03 (PG 6) GS 95006-7-1:2021-11 (PG 6) MBN 10384:2010-11 (PG 6) SAE/USCAR-2:2020-02 (p. 5.4.8) SAE/USCAR-2:2022-06 (p. 5.4.8) SAE/USCAR-2:2024-12 (p. 5.4.8) VW 80302:2013-03 Scope of accreditation No. AB 1776 Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Odpornosc na uszkodzenia mechaniczne IEC 60068-2-31:2008 VW 75174:2018-10 (TG 6) VW 80332:2024-01 (TG 6) LV 214:2010-03 (PG 6) GS 95006-7-1:2016-03 (PG 6) GS 95006-7-1:2021-11 (PG 6) MBN 10384:2010-11 (PG 6) SAE/USCAR-2:2020-02 (p. 5.4.8) SAE/USCAR-2:2022-06 (p. 5.4.8) SAE/USCAR-2:2024-12 (p. 5.4.8) VW 80302:2013-03 Scope of accreditation No. AB 1776","categories":["electronics"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Resistance to mechanical damage IEC 60068-2-31:2008 VW 75174:2018-10 (TG 6) VW 80332:2024-01 (TG 6) LV 214:2010-03 (PG 6) GS 95006-7-1:2016-03 (PG 6) GS 95006-7-1:2021-11 (PG 6) MBN 10384:2010-11 (PG 6) SAE/USCAR-2:2020-02 (p. 5.4.8) SAE/USCAR-2:2022-06 (p. 5.4.8) SAE/USCAR-2:2024-12 (p. 5.4.8) VW 80302:2013-03 Scope of accreditation No. AB 1776","search_zh":"汽车电气与电子设备的部件/组件 IEC 60068-2-31:2008 VW 75174:2018-10 (TG 6) VW 80332:2024-01 (TG 6) LV 214:2010-03 (PG 6) GS 95006-7-1:2016-03 (PG 6) GS 95006-7-1:2021-11 (PG 6) MBN 10384:2010-11 (PG 6) SAE/USCAR-2:2020-02 (p. 5.4.8) SAE/USCAR-2:2022-06 (p. 5.4.8) SAE/USCAR-2:2024-12 (p. 5.4.8) VW 80302:2013-03 Scope of accreditation No. AB 1776","test_object_zh":"汽车电气与电子设备的部件/组件"},{"_id":"6a5dc9a9f1c10c8ce8259ea3","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Badania mechaniczne na złączach","methodology_en":"Mechanical tests on joints","parameters":[{"name":"elektrycznych."},{"name":"Siła:"},{"name":"zrywania,"},{"name":"wyrywania,"},{"name":"wciskania/wkładania i wyjmowania,"},{"name":"wypychania;"},{"name":"otwierania i zamykania,"},{"name":"łączenia i rozłączania,"},{"name":"włączania i wyłączania,"},{"name":"utrzymania,"},{"name":"polaryzacji,"},{"name":"kodowania,"},{"name":"manewrowania."},{"name":"rozrywania pod kątem prostym"},{"name":"rozrywania osiowego"},{"name":"Zakres","range":"0,1 N - 20 kN"},{"name":"Zakres","range":"0,1 N - 3 kN (dotyczy obiektów"},{"name":"do badań typu zgrzewy USW)"}],"parameters_en":[{"name":"electrical."},{"name":"Force:"},{"name":"breaking,"},{"name":"pull-out,"},{"name":"pushing in/inserting and withdrawing,"},{"name":"pushing out;"},{"name":"opening and closing,"},{"name":"making and breaking,"},{"name":"switching on and off,"},{"name":"maintenance,"},{"name":"polarisation,"},{"name":"coding,"},{"name":"manoeuvring."},{"name":"tearing at right angles"},{"name":"axial tearing"},{"name":"Range","range":"0,1 N - 20 kN"},{"name":"Range","range":"0,1 N - 3 kN (dotyczy obiektów"},{"name":"for type testing of USW welds)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania mechaniczne na złączach\nZakres:\nelektrycznych.\nSiła:\nzrywania,\nwyrywania,\nwciskania/wkładania i wyjmowania,\nwypychania;\notwierania i zamykania,\nłączenia i rozłączania,\nwłączania i wyłączania,\nutrzymania,\npolaryzacji,\nkodowania,\nmanewrowania.\nrozrywania pod kątem prostym\nrozrywania osiowego\nZakres 0,1 N - 20 kN\nZakres 0,1 N - 3 kN (dotyczy obiektów\ndo badań typu zgrzewy USW)","reference":"IEC 60512-13-5:2006 | IEC 60512-15-6:2008 | ISO 8092-2:2005-12-01 (p. 4.3) | ISO 8092-2:2023:2023-09 (p. 5.1, 5.2, 5.4) | ISO 19072-2:2019-12 (p. 4.3; 4.4) | ISO 19072-2:2007-10-01 (p. 4.3; 4.4) VW 75174: 2018-10 (E 6.4; P 6.4; TG 7, TG 8, TG 10, TG 11, TG 31) LV 214:2010-03 (E 6.4; PG 7, PG 8, PG 10, PG 11) GS 95006-7-1:2016-03 (E 6.4; PG 7, PG 8, PG 10, PG 11) GS 95006-7-1:2021-11 (E 6.4; PG 7, PG 8, PG 10, PG 11) MBN 10384:2010-11 (E 6.4; PG 7, PG 8, PG 10, PG 11) SAE/USCAR-2:2020-02 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) SAE/USCAR-2:2022-06 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) SAE/USCAR-2:2024-12 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) SAE/USCAR-21:2020-01 VW 80332:2017-09 (PG 8; PG 10; PG 11) VW 80332:2019-01 (PG 8; PG 10; PG 11) VW 80332:2021-02 (PG 7; PG 8; PG 10; PG 11) VW 80332:2024-01 (TG 7; TG 8; TG 10; TG 11) MBN LV 215:2017-08 (PG 8; PG 10; PG 11) A 009 000 04 99:2013-07 (p. 3.4: E 11s.1; E 11s.2) VW 60307:2019-11 (p.7.1.2, 7.1.3) Audi Prufmatrix:2017-02-15 MVL 9 902 1040 Delphi 33330950:2016-10-04 (p. 3.1; 3.2) MVL 9 902 10 40 Aptiv 33330950-INS01:2022-05-09 (p. 5.3.1; 5.3.2) MVL 9 902 10 40 Aptiv 33330950-INS02:2022-05-09 (p. 3.1; 3.2) Scope of accreditation No. AB 1776","norm_bases":["IEC 60512-13-5:2006","IEC 60512-15-6:2008","ISO 8092-2:2005-12-01 (p. 4.3)","ISO 8092-2:2023:2023-09 (p. 5.1, 5.2, 5.4)","ISO 19072-2:2019-12 (p. 4.3; 4.4)","ISO 19072-2:2007-10-01 (p. 4.3; 4.4) VW 75174: 2018-10 (E 6.4; P 6.4; TG 7, TG 8, TG 10, TG 11, TG 31) LV 214:2010-03 (E 6.4; PG 7, PG 8, PG 10, PG 11) GS 95006-7-1:2016-03 (E 6.4; PG 7, PG 8, PG 10, PG 11) GS 95006-7-1:2021-11 (E 6.4; PG 7, PG 8, PG 10, PG 11) MBN 10384:2010-11 (E 6.4; PG 7, PG 8, PG 10, PG 11) SAE/USCAR-2:2020-02 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) SAE/USCAR-2:2022-06 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) SAE/USCAR-2:2024-12 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) SAE/USCAR-21:2020-01 VW 80332:2017-09 (PG 8; PG 10; PG 11) VW 80332:2019-01 (PG 8; PG 10; PG 11) VW 80332:2021-02 (PG 7; PG 8; PG 10; PG 11) VW 80332:2024-01 (TG 7; TG 8; TG 10; TG 11) MBN LV 215:2017-08 (PG 8; PG 10; PG 11) A 009 000 04 99:2013-07 (p. 3.4: E 11s.1; E 11s.2) VW 60307:2019-11 (p.7.1.2, 7.1.3) Audi Prufmatrix:2017-02-15 MVL 9 902 1040 Delphi 33330950:2016-10-04 (p. 3.1; 3.2) MVL 9 902 10 40 Aptiv 33330950-INS01:2022-05-09 (p. 5.3.1; 5.3.2) MVL 9 902 10 40 Aptiv 33330950-INS02:2022-05-09 (p. 3.1; 3.2) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Badania mechaniczne na złączach\nZakres:\nelektrycznych.\nSiła:\nzrywania,\nwyrywania,\nwciskania/wkładania i wyjmowania,\nwypychania;\notwierania i zamykania,\nłączenia i rozłączania,\nwłączania i wyłączania,\nutrzymania,\npolaryzacji,\nkodowania,\nmanewrowania.\nrozrywania pod kątem prostym\nrozrywania osiowego\nZakres 0,1 N - 20 kN\nZakres 0,1 N - 3 kN (dotyczy obiektów\ndo badań typu zgrzewy USW) IEC 60512-13-5:2006 | IEC 60512-15-6:2008 | ISO 8092-2:2005-12-01 (p. 4.3) | ISO 8092-2:2023:2023-09 (p. 5.1, 5.2, 5.4) | ISO 19072-2:2019-12 (p. 4.3; 4.4) | ISO 19072-2:2007-10-01 (p. 4.3; 4.4) VW 75174: 2018-10 (E 6.4; P 6.4; TG 7, TG 8, TG 10, TG 11, TG 31) LV 214:2010-03 (E 6.4; PG 7, PG 8, PG 10, PG 11) GS 95006-7-1:2016-03 (E 6.4; PG 7, PG 8, PG 10, PG 11) GS 95006-7-1:2021-11 (E 6.4; PG 7, PG 8, PG 10, PG 11) MBN 10384:2010-11 (E 6.4; PG 7, PG 8, PG 10, PG 11) SAE/USCAR-2:2020-02 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) SAE/USCAR-2:2022-06 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) SAE/USCAR-2:2024-12 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) SAE/USCAR-21:2020-01 VW 80332:2017-09 (PG 8; PG 10; PG 11) VW 80332:2019-01 (PG 8; PG 10; PG 11) VW 80332:2021-02 (PG 7; PG 8; PG 10; PG 11) VW 80332:2024-01 (TG 7; TG 8; TG 10; TG 11) MBN LV 215:2017-08 (PG 8; PG 10; PG 11) A 009 000 04 99:2013-07 (p. 3.4: E 11s.1; E 11s.2) VW 60307:2019-11 (p.7.1.2, 7.1.3) Audi Prufmatrix:2017-02-15 MVL 9 902 1040 Delphi 33330950:2016-10-04 (p. 3.1; 3.2) MVL 9 902 10 40 Aptiv 33330950-INS01:2022-05-09 (p. 5.3.1; 5.3.2) MVL 9 902 10 40 Aptiv 33330950-INS02:2022-05-09 (p. 3.1; 3.2) Scope of accreditation No. AB 1776 Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Badania mechaniczne na zlaczach\nZakres:\nelektrycznych.\nSila:\nzrywania,\nwyrywania,\nwciskania/wkladania i wyjmowania,\nwypychania;\notwierania i zamykania,\nlaczenia i rozlaczania,\nwlaczania i wylaczania,\nutrzymania,\npolaryzacji,\nkodowania,\nmanewrowania.\nrozrywania pod katem prostym\nrozrywania osiowego\nZakres 0,1 N - 20 kN\nZakres 0,1 N - 3 kN (dotyczy obiektow\ndo badan typu zgrzewy USW) IEC 60512-13-5:2006 | IEC 60512-15-6:2008 | ISO 8092-2:2005-12-01 (p. 4.3) | ISO 8092-2:2023:2023-09 (p. 5.1, 5.2, 5.4) | ISO 19072-2:2019-12 (p. 4.3; 4.4) | ISO 19072-2:2007-10-01 (p. 4.3; 4.4) VW 75174: 2018-10 (E 6.4; P 6.4; TG 7, TG 8, TG 10, TG 11, TG 31) LV 214:2010-03 (E 6.4; PG 7, PG 8, PG 10, PG 11) GS 95006-7-1:2016-03 (E 6.4; PG 7, PG 8, PG 10, PG 11) GS 95006-7-1:2021-11 (E 6.4; PG 7, PG 8, PG 10, PG 11) MBN 10384:2010-11 (E 6.4; PG 7, PG 8, PG 10, PG 11) SAE/USCAR-2:2020-02 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) SAE/USCAR-2:2022-06 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) SAE/USCAR-2:2024-12 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) SAE/USCAR-21:2020-01 VW 80332:2017-09 (PG 8; PG 10; PG 11) VW 80332:2019-01 (PG 8; PG 10; PG 11) VW 80332:2021-02 (PG 7; PG 8; PG 10; PG 11) VW 80332:2024-01 (TG 7; TG 8; TG 10; TG 11) MBN LV 215:2017-08 (PG 8; PG 10; PG 11) A 009 000 04 99:2013-07 (p. 3.4: E 11s.1; E 11s.2) VW 60307:2019-11 (p.7.1.2, 7.1.3) Audi Prufmatrix:2017-02-15 MVL 9 902 1040 Delphi 33330950:2016-10-04 (p. 3.1; 3.2) MVL 9 902 10 40 Aptiv 33330950-INS01:2022-05-09 (p. 5.3.1; 5.3.2) MVL 9 902 10 40 Aptiv 33330950-INS02:2022-05-09 (p. 3.1; 3.2) Scope of accreditation No. AB 1776","categories":["electronics"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Mechanical tests on joints electrical. Force: breaking, pull-out, pushing in/inserting and withdrawing, pushing out; opening and closing, making and breaking, switching on and off, maintenance, polarisation, coding, manoeuvring. tearing at right angles axial tearing Range Range for type testing of USW welds) IEC 60512-13-5:2006 | IEC 60512-15-6:2008 | ISO 8092-2:2005-12-01 (p. 4.3) | ISO 8092-2:2023:2023-09 (p. 5.1, 5.2, 5.4) | ISO 19072-2:2019-12 (p. 4.3; 4.4) | ISO 19072-2:2007-10-01 (p. 4.3; 4.4) VW 75174: 2018-10 (E 6.4; P 6.4; TG 7, TG 8, TG 10, TG 11, TG 31) LV 214:2010-03 (E 6.4; PG 7, PG 8, PG 10, PG 11) GS 95006-7-1:2016-03 (E 6.4; PG 7, PG 8, PG 10, PG 11) GS 95006-7-1:2021-11 (E 6.4; PG 7, PG 8, PG 10, PG 11) MBN 10384:2010-11 (E 6.4; PG 7, PG 8, PG 10, PG 11) SAE/USCAR-2:2020-02 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) SAE/USCAR-2:2022-06 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) SAE/USCAR-2:2024-12 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) SAE/USCAR-21:2020-01 VW 80332:2017-09 (PG 8; PG 10; PG 11) VW 80332:2019-01 (PG 8; PG 10; PG 11) VW 80332:2021-02 (PG 7; PG 8; PG 10; PG 11) VW 80332:2024-01 (TG 7; TG 8; TG 10; TG 11) MBN LV 215:2017-08 (PG 8; PG 10; PG 11) A 009 000 04 99:2013-07 (p. 3.4: E 11s.1; E 11s.2) VW 60307:2019-11 (p.7.1.2, 7.1.3) Audi Prufmatrix:2017-02-15 MVL 9 902 1040 Delphi 33330950:2016-10-04 (p. 3.1; 3.2) MVL 9 902 10 40 Aptiv 33330950-INS01:2022-05-09 (p. 5.3.1; 5.3.2) MVL 9 902 10 40 Aptiv 33330950-INS02:2022-05-09 (p. 3.1; 3.2) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"elektrycznych."},{"name":"Siła:"},{"name":"zrywania,"},{"name":"wyrywania,"},{"name":"wciskania/wkładania i wyjmowania,"},{"name":"wypychania;"},{"name":"otwierania i zamykania,"},{"name":"łączenia i rozłączania,"},{"name":"włączania i wyłączania,"},{"name":"utrzymania,"},{"name":"polaryzacji,"},{"name":"kodowania,"},{"name":"manewrowania."},{"name":"rozrywania pod kątem prostym"},{"name":"rozrywania osiowego"},{"name":"范围","range":"0,1 N - 20 kN"},{"name":"范围","range":"0,1 N - 3 kN (dotyczy obiektów"},{"name":"do badań typu zgrzewy USW)"}],"search_zh":"汽车电气与电子设备的部件/组件 范围 范围 IEC 60512-13-5:2006 | IEC 60512-15-6:2008 | ISO 8092-2:2005-12-01 (p. 4.3) | ISO 8092-2:2023:2023-09 (p. 5.1, 5.2, 5.4) | ISO 19072-2:2019-12 (p. 4.3; 4.4) | ISO 19072-2:2007-10-01 (p. 4.3; 4.4) VW 75174: 2018-10 (E 6.4; P 6.4; TG 7, TG 8, TG 10, TG 11, TG 31) LV 214:2010-03 (E 6.4; PG 7, PG 8, PG 10, PG 11) GS 95006-7-1:2016-03 (E 6.4; PG 7, PG 8, PG 10, PG 11) GS 95006-7-1:2021-11 (E 6.4; PG 7, PG 8, PG 10, PG 11) MBN 10384:2010-11 (E 6.4; PG 7, PG 8, PG 10, PG 11) SAE/USCAR-2:2020-02 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) SAE/USCAR-2:2022-06 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) SAE/USCAR-2:2024-12 (p. 5.2.1; 5.2.2; 5.4.1; 5.4.2; 5.4.3; 5.4.4.; 5.4.5; 5.4.9; 5.4.10; 5.4.11; 5.4.12; 5.4.14; 5.7.1) SAE/USCAR-21:2020-01 VW 80332:2017-09 (PG 8; PG 10; PG 11) VW 80332:2019-01 (PG 8; PG 10; PG 11) VW 80332:2021-02 (PG 7; PG 8; PG 10; PG 11) VW 80332:2024-01 (TG 7; TG 8; TG 10; TG 11) MBN LV 215:2017-08 (PG 8; PG 10; PG 11) A 009 000 04 99:2013-07 (p. 3.4: E 11s.1; E 11s.2) VW 60307:2019-11 (p.7.1.2, 7.1.3) Audi Prufmatrix:2017-02-15 MVL 9 902 1040 Delphi 33330950:2016-10-04 (p. 3.1; 3.2) MVL 9 902 10 40 Aptiv 33330950-INS01:2022-05-09 (p. 5.3.1; 5.3.2) MVL 9 902 10 40 Aptiv 33330950-INS02:2022-05-09 (p. 3.1; 3.2) Scope of accreditation No. AB 1776","test_object_zh":"汽车电气与电子设备的部件/组件"},{"_id":"6a5dc9a9f1c10c8ce8259ea4","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Badanie obciążalności prądowej","methodology_en":"Current-carrying capacity testing","parameters":[{"name":"Natężenie prądu","range":"do 1000 A"},{"name":"Temperatura obiektu","range":"do 200°C"},{"name":"Przyrost temperatury w funkcji natężenia prądu"},{"name":"Obciążalność prądowa w funkcji temperatury"},{"name":"Termiczna stała czasowa"}],"parameters_en":[{"name":"Electric current","range":"do 1000 A"},{"name":"Object temperature","range":"do 200°C"},{"name":"Temperature rise as a function of current"},{"name":"Current-carrying capacity as a function of temperature"},{"name":"Thermal time constant"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badanie obciążalności prądowej\nZakres:\nNatężenie prądu do 1000 A\nTemperatura obiektu do 200°C\nPrzyrost temperatury w funkcji natężenia prądu\nObciążalność prądowa w funkcji temperatury\nTermiczna stała czasowa","reference":"IEC 60512-5-1:2002 | IEC 60512-5-2:2002 VW 75174:2018-10 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1; P 12.1; P 13.1; P 12.2; P 13.2; P 14.1) LV 214:2010-03 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) GS 95006-7-1:2016-03, (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) GS 95006-7-1:2021-11 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) MBN 10384:2010-11 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) SAE/USCAR-2:2020-02 (p. 5.3.3) SAE/USCAR-2:2022-06 (p. 5.3.3) SAE/USCAR-2:2024-12 (p. 5.3.3) VW 80332:2017-09 (PG 12; PG 13; PG 14) VW 80332:2019-01 (PG 12; PG 13; PG 14) VW 80332:2021-02 (PG 12; PG 13; PG 14) VW 80332:2024-01 (TG 12; TG 13; TG 14) MBN LV 215:2017-08 (PG 12; PG 13; PG 14)","norm_bases":["IEC 60512-5-1:2002","IEC 60512-5-2:2002 VW 75174:2018-10 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1; P 12.1; P 13.1; P 12.2; P 13.2; P 14.1) LV 214:2010-03 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) GS 95006-7-1:2016-03, (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) GS 95006-7-1:2021-11 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) MBN 10384:2010-11 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) SAE/USCAR-2:2020-02 (p. 5.3.3) SAE/USCAR-2:2022-06 (p. 5.3.3) SAE/USCAR-2:2024-12 (p. 5.3.3) VW 80332:2017-09 (PG 12; PG 13; PG 14) VW 80332:2019-01 (PG 12; PG 13; PG 14) VW 80332:2021-02 (PG 12; PG 13; PG 14) VW 80332:2024-01 (TG 12; TG 13; TG 14) MBN LV 215:2017-08 (PG 12; PG 13; PG 14)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Badanie obciążalności prądowej\nZakres:\nNatężenie prądu do 1000 A\nTemperatura obiektu do 200°C\nPrzyrost temperatury w funkcji natężenia prądu\nObciążalność prądowa w funkcji temperatury\nTermiczna stała czasowa IEC 60512-5-1:2002 | IEC 60512-5-2:2002 VW 75174:2018-10 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1; P 12.1; P 13.1; P 12.2; P 13.2; P 14.1) LV 214:2010-03 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) GS 95006-7-1:2016-03, (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) GS 95006-7-1:2021-11 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) MBN 10384:2010-11 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) SAE/USCAR-2:2020-02 (p. 5.3.3) SAE/USCAR-2:2022-06 (p. 5.3.3) SAE/USCAR-2:2024-12 (p. 5.3.3) VW 80332:2017-09 (PG 12; PG 13; PG 14) VW 80332:2019-01 (PG 12; PG 13; PG 14) VW 80332:2021-02 (PG 12; PG 13; PG 14) VW 80332:2024-01 (TG 12; TG 13; TG 14) MBN LV 215:2017-08 (PG 12; PG 13; PG 14) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Badanie obciazalnosci pradowej\nZakres:\nNatezenie pradu do 1000 A\nTemperatura obiektu do 200°C\nPrzyrost temperatury w funkcji natezenia pradu\nObciazalnosc pradowa w funkcji temperatury\nTermiczna stala czasowa IEC 60512-5-1:2002 | IEC 60512-5-2:2002 VW 75174:2018-10 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1; P 12.1; P 13.1; P 12.2; P 13.2; P 14.1) LV 214:2010-03 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) GS 95006-7-1:2016-03, (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) GS 95006-7-1:2021-11 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) MBN 10384:2010-11 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) SAE/USCAR-2:2020-02 (p. 5.3.3) SAE/USCAR-2:2022-06 (p. 5.3.3) SAE/USCAR-2:2024-12 (p. 5.3.3) VW 80332:2017-09 (PG 12; PG 13; PG 14) VW 80332:2019-01 (PG 12; PG 13; PG 14) VW 80332:2021-02 (PG 12; PG 13; PG 14) VW 80332:2024-01 (TG 12; TG 13; TG 14) MBN LV 215:2017-08 (PG 12; PG 13; PG 14)","categories":["electronics"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Current-carrying capacity testing Electric current Object temperature Temperature rise as a function of current Current-carrying capacity as a function of temperature Thermal time constant IEC 60512-5-1:2002 | IEC 60512-5-2:2002 VW 75174:2018-10 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1; P 12.1; P 13.1; P 12.2; P 13.2; P 14.1) LV 214:2010-03 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) GS 95006-7-1:2016-03, (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) GS 95006-7-1:2021-11 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) MBN 10384:2010-11 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) SAE/USCAR-2:2020-02 (p. 5.3.3) SAE/USCAR-2:2022-06 (p. 5.3.3) SAE/USCAR-2:2024-12 (p. 5.3.3) VW 80332:2017-09 (PG 12; PG 13; PG 14) VW 80332:2019-01 (PG 12; PG 13; PG 14) VW 80332:2021-02 (PG 12; PG 13; PG 14) VW 80332:2024-01 (TG 12; TG 13; TG 14) MBN LV 215:2017-08 (PG 12; PG 13; PG 14)","search_zh":"汽车电气与电子设备的部件/组件 IEC 60512-5-1:2002 | IEC 60512-5-2:2002 VW 75174:2018-10 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1; P 12.1; P 13.1; P 12.2; P 13.2; P 14.1) LV 214:2010-03 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) GS 95006-7-1:2016-03, (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) GS 95006-7-1:2021-11 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) MBN 10384:2010-11 (p. E 12.1; E 13.1; E 12.2; E 13.2; E 14.1) SAE/USCAR-2:2020-02 (p. 5.3.3) SAE/USCAR-2:2022-06 (p. 5.3.3) SAE/USCAR-2:2024-12 (p. 5.3.3) VW 80332:2017-09 (PG 12; PG 13; PG 14) VW 80332:2019-01 (PG 12; PG 13; PG 14) VW 80332:2021-02 (PG 12; PG 13; PG 14) VW 80332:2024-01 (TG 12; TG 13; TG 14) MBN LV 215:2017-08 (PG 12; PG 13; PG 14)","test_object_zh":"汽车电气与电子设备的部件/组件"},{"_id":"6a5dc9a9f1c10c8ce8259ea5","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Wytrzymałość temperaturowo-prądowa","methodology_en":"Temperature-current endurance","parameters":[{"name":"Temperatura środowiska: (-40 - 175) °C","range":"(± 2 °C)"},{"name":"Temperatura obiektu","range":"do 200 °C"},{"name":"Natężenie prądu","range":"do 1000 A"}],"parameters_en":[{"name":"Ambient temperature: (-40 - 175) °C","range":"(± 2 °C)"},{"name":"Object temperature","range":"do 200 °C"},{"name":"Electric current","range":"do 1000 A"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość temperaturowo-prądowa\nZakres:\nTemperatura środowiska: (-40 - 175) °C (± 2 °C)\nTemperatura obiektu do 200 °C\nNatężenie prądu do 1000 A","reference":"VW 75174:2018-10 (p. B 15.2; L 15.2) LV 214:2010-03 (p. B 15.2) GS 95006-7-1:2016-03 (p. B 15.2) GS 95006-7-1:2021-11 (p. B 15.2) MBN 10384:2010-11 (p. B 15.2) SAE/USCAR-2:2020-02 (p. 5.3.4) SAE/USCAR-2:2022-06 (p. 5.3.4) SAE/USCAR-2:2024-12 (p. 5.3.4) SAE/USCAR-21:2020-01 (p. 4.5.1) VW 80332:2017-09 (PG 15) VW 80332:2019-01 (PG 15) VW 80332:2021-02 (PG 15) VW 80332:2024-01 (TG 15) MBN LV 215:2017-08 (PG 15) Scope of accreditation No. AB 1776","norm_bases":["VW 75174:2018-10 (p. B 15.2; L 15.2) LV 214:2010-03 (p. B 15.2) GS 95006-7-1:2016-03 (p. B 15.2) GS 95006-7-1:2021-11 (p. B 15.2) MBN 10384:2010-11 (p. B 15.2) SAE/USCAR-2:2020-02 (p. 5.3.4) SAE/USCAR-2:2022-06 (p. 5.3.4) SAE/USCAR-2:2024-12 (p. 5.3.4) SAE/USCAR-21:2020-01 (p. 4.5.1) VW 80332:2017-09 (PG 15) VW 80332:2019-01 (PG 15) VW 80332:2021-02 (PG 15) VW 80332:2024-01 (TG 15) MBN LV 215:2017-08 (PG 15) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Wytrzymałość temperaturowo-prądowa\nZakres:\nTemperatura środowiska: (-40 - 175) °C (± 2 °C)\nTemperatura obiektu do 200 °C\nNatężenie prądu do 1000 A VW 75174:2018-10 (p. B 15.2; L 15.2) LV 214:2010-03 (p. B 15.2) GS 95006-7-1:2016-03 (p. B 15.2) GS 95006-7-1:2021-11 (p. B 15.2) MBN 10384:2010-11 (p. B 15.2) SAE/USCAR-2:2020-02 (p. 5.3.4) SAE/USCAR-2:2022-06 (p. 5.3.4) SAE/USCAR-2:2024-12 (p. 5.3.4) SAE/USCAR-21:2020-01 (p. 4.5.1) VW 80332:2017-09 (PG 15) VW 80332:2019-01 (PG 15) VW 80332:2021-02 (PG 15) VW 80332:2024-01 (TG 15) MBN LV 215:2017-08 (PG 15) Scope of accreditation No. AB 1776 Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Wytrzymalosc temperaturowo-pradowa\nZakres:\nTemperatura srodowiska: (-40 - 175) °C (± 2 °C)\nTemperatura obiektu do 200 °C\nNatezenie pradu do 1000 A VW 75174:2018-10 (p. B 15.2; L 15.2) LV 214:2010-03 (p. B 15.2) GS 95006-7-1:2016-03 (p. B 15.2) GS 95006-7-1:2021-11 (p. B 15.2) MBN 10384:2010-11 (p. B 15.2) SAE/USCAR-2:2020-02 (p. 5.3.4) SAE/USCAR-2:2022-06 (p. 5.3.4) SAE/USCAR-2:2024-12 (p. 5.3.4) SAE/USCAR-21:2020-01 (p. 4.5.1) VW 80332:2017-09 (PG 15) VW 80332:2019-01 (PG 15) VW 80332:2021-02 (PG 15) VW 80332:2024-01 (TG 15) MBN LV 215:2017-08 (PG 15) Scope of accreditation No. AB 1776","categories":["environment","electronics"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Temperature-current endurance Ambient temperature: (-40 - 175) °C Object temperature Electric current VW 75174:2018-10 (p. B 15.2; L 15.2) LV 214:2010-03 (p. B 15.2) GS 95006-7-1:2016-03 (p. B 15.2) GS 95006-7-1:2021-11 (p. B 15.2) MBN 10384:2010-11 (p. B 15.2) SAE/USCAR-2:2020-02 (p. 5.3.4) SAE/USCAR-2:2022-06 (p. 5.3.4) SAE/USCAR-2:2024-12 (p. 5.3.4) SAE/USCAR-21:2020-01 (p. 4.5.1) VW 80332:2017-09 (PG 15) VW 80332:2019-01 (PG 15) VW 80332:2021-02 (PG 15) VW 80332:2024-01 (TG 15) MBN LV 215:2017-08 (PG 15) Scope of accreditation No. AB 1776","search_zh":"汽车电气与电子设备的部件/组件 VW 75174:2018-10 (p. B 15.2; L 15.2) LV 214:2010-03 (p. B 15.2) GS 95006-7-1:2016-03 (p. B 15.2) GS 95006-7-1:2021-11 (p. B 15.2) MBN 10384:2010-11 (p. B 15.2) SAE/USCAR-2:2020-02 (p. 5.3.4) SAE/USCAR-2:2022-06 (p. 5.3.4) SAE/USCAR-2:2024-12 (p. 5.3.4) SAE/USCAR-21:2020-01 (p. 4.5.1) VW 80332:2017-09 (PG 15) VW 80332:2019-01 (PG 15) VW 80332:2021-02 (PG 15) VW 80332:2024-01 (TG 15) MBN LV 215:2017-08 (PG 15) Scope of accreditation No. AB 1776","test_object_zh":"汽车电气与电子设备的部件/组件"},{"_id":"6a5dc9a9f1c10c8ce8259ea6","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Badania wibracyjne","methodology_en":"Vibration testing","parameters":[{"name":"Częstotliwość","range":"(5 – 2500) Hz"},{"name":"Przemieszczenie","range":"do 62 mm (p-p)"},{"name":"Przyśpieszenie: amax:"},{"name":"Wibracje sinusoidalne do 50 g (peak)"},{"name":"Udary mechaniczne do 100 g (peak)"},{"name":"Wibracje przypadkowe"}],"parameters_en":[{"name":"Frequency","range":"(5 – 2500) Hz"},{"name":"Displacement","range":"do 62 mm (p-p)"},{"name":"Acceleration: amax:"},{"name":"Sinusoidal vibration up to 50 g (peak)"},{"name":"Mechanical shocks up to 100 g (peak)"},{"name":"Random vibration"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania wibracyjne\nZakres:\nCzęstotliwość (5 – 2500) Hz\nPrzemieszczenie do 62 mm (p-p)\nPrzyśpieszenie: amax:\nWibracje sinusoidalne do 50 g (peak)\nUdary mechaniczne do 100 g (peak)\nWibracje przypadkowe","reference":"IEC 60068-2-6:2007 | IEC 60068-2-64:2008 | IEC 60068-2-64:2019-10 | IEC 60068-2-27:2009 VW 75174:2018-10 (p. B 19.6; B 19.7; L 19.6; L 19.7; TG 17) LV 214:2010-03 (p. B 19.6; B 19.7; PG 17) GS 95006-7-1:2016-03 (p. B 19.6; B 19.7; PG 17) GS 95006-7-1:2021-11 (p. B 19.6; B 19.7; PG 17) MBN 10384:2010-11 (p. B 19.6; B 19.7; PG 17) SAE/USCAR-2:2020-02 (p. 5.4.6) SAE/USCAR-2:2022-06 (p. 5.4.6) SAE/USCAR-2:2024-12 (p. 5.4.6) VW 80332:2017-09 (PG 17) VW 80332:2019-01 (PG 17) VW 80332:2021-02 (PG 17) VW 80332:2024-01 (TG 17) MBN LV 215:2017-08 (PG 17) A 009 000 04 99:2013-07","norm_bases":["IEC 60068-2-6:2007","IEC 60068-2-64:2008","IEC 60068-2-64:2019-10","IEC 60068-2-27:2009 VW 75174:2018-10 (p. B 19.6; B 19.7; L 19.6; L 19.7; TG 17) LV 214:2010-03 (p. B 19.6; B 19.7; PG 17) GS 95006-7-1:2016-03 (p. B 19.6; B 19.7; PG 17) GS 95006-7-1:2021-11 (p. B 19.6; B 19.7; PG 17) MBN 10384:2010-11 (p. B 19.6; B 19.7; PG 17) SAE/USCAR-2:2020-02 (p. 5.4.6) SAE/USCAR-2:2022-06 (p. 5.4.6) SAE/USCAR-2:2024-12 (p. 5.4.6) VW 80332:2017-09 (PG 17) VW 80332:2019-01 (PG 17) VW 80332:2021-02 (PG 17) VW 80332:2024-01 (TG 17) MBN LV 215:2017-08 (PG 17) A 009 000 04 99:2013-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Badania wibracyjne\nZakres:\nCzęstotliwość (5 – 2500) Hz\nPrzemieszczenie do 62 mm (p-p)\nPrzyśpieszenie: amax:\nWibracje sinusoidalne do 50 g (peak)\nUdary mechaniczne do 100 g (peak)\nWibracje przypadkowe IEC 60068-2-6:2007 | IEC 60068-2-64:2008 | IEC 60068-2-64:2019-10 | IEC 60068-2-27:2009 VW 75174:2018-10 (p. B 19.6; B 19.7; L 19.6; L 19.7; TG 17) LV 214:2010-03 (p. B 19.6; B 19.7; PG 17) GS 95006-7-1:2016-03 (p. B 19.6; B 19.7; PG 17) GS 95006-7-1:2021-11 (p. B 19.6; B 19.7; PG 17) MBN 10384:2010-11 (p. B 19.6; B 19.7; PG 17) SAE/USCAR-2:2020-02 (p. 5.4.6) SAE/USCAR-2:2022-06 (p. 5.4.6) SAE/USCAR-2:2024-12 (p. 5.4.6) VW 80332:2017-09 (PG 17) VW 80332:2019-01 (PG 17) VW 80332:2021-02 (PG 17) VW 80332:2024-01 (TG 17) MBN LV 215:2017-08 (PG 17) A 009 000 04 99:2013-07 Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Badania wibracyjne\nZakres:\nCzestotliwosc (5 – 2500) Hz\nPrzemieszczenie do 62 mm (p-p)\nPrzyspieszenie: amax:\nWibracje sinusoidalne do 50 g (peak)\nUdary mechaniczne do 100 g (peak)\nWibracje przypadkowe IEC 60068-2-6:2007 | IEC 60068-2-64:2008 | IEC 60068-2-64:2019-10 | IEC 60068-2-27:2009 VW 75174:2018-10 (p. B 19.6; B 19.7; L 19.6; L 19.7; TG 17) LV 214:2010-03 (p. B 19.6; B 19.7; PG 17) GS 95006-7-1:2016-03 (p. B 19.6; B 19.7; PG 17) GS 95006-7-1:2021-11 (p. B 19.6; B 19.7; PG 17) MBN 10384:2010-11 (p. B 19.6; B 19.7; PG 17) SAE/USCAR-2:2020-02 (p. 5.4.6) SAE/USCAR-2:2022-06 (p. 5.4.6) SAE/USCAR-2:2024-12 (p. 5.4.6) VW 80332:2017-09 (PG 17) VW 80332:2019-01 (PG 17) VW 80332:2021-02 (PG 17) VW 80332:2024-01 (TG 17) MBN LV 215:2017-08 (PG 17) A 009 000 04 99:2013-07","categories":["electronics"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Vibration testing Frequency Displacement Acceleration: amax: Sinusoidal vibration up to 50 g (peak) Mechanical shocks up to 100 g (peak) Random vibration IEC 60068-2-6:2007 | IEC 60068-2-64:2008 | IEC 60068-2-64:2019-10 | IEC 60068-2-27:2009 VW 75174:2018-10 (p. B 19.6; B 19.7; L 19.6; L 19.7; TG 17) LV 214:2010-03 (p. B 19.6; B 19.7; PG 17) GS 95006-7-1:2016-03 (p. B 19.6; B 19.7; PG 17) GS 95006-7-1:2021-11 (p. B 19.6; B 19.7; PG 17) MBN 10384:2010-11 (p. B 19.6; B 19.7; PG 17) SAE/USCAR-2:2020-02 (p. 5.4.6) SAE/USCAR-2:2022-06 (p. 5.4.6) SAE/USCAR-2:2024-12 (p. 5.4.6) VW 80332:2017-09 (PG 17) VW 80332:2019-01 (PG 17) VW 80332:2021-02 (PG 17) VW 80332:2024-01 (TG 17) MBN LV 215:2017-08 (PG 17) A 009 000 04 99:2013-07","parameters_zh":[{"name":"频率","range":"(5 – 2500) Hz"},{"name":"位移","range":"do 62 mm (p-p)"},{"name":"Przyśpieszenie: amax:"},{"name":"Wibracje sinusoidalne do 50 g (peak)"},{"name":"Udary mechaniczne do 100 g (peak)"},{"name":"Wibracje przypadkowe"}],"search_zh":"汽车电气与电子设备的部件/组件 频率 位移 IEC 60068-2-6:2007 | IEC 60068-2-64:2008 | IEC 60068-2-64:2019-10 | IEC 60068-2-27:2009 VW 75174:2018-10 (p. B 19.6; B 19.7; L 19.6; L 19.7; TG 17) LV 214:2010-03 (p. B 19.6; B 19.7; PG 17) GS 95006-7-1:2016-03 (p. B 19.6; B 19.7; PG 17) GS 95006-7-1:2021-11 (p. B 19.6; B 19.7; PG 17) MBN 10384:2010-11 (p. B 19.6; B 19.7; PG 17) SAE/USCAR-2:2020-02 (p. 5.4.6) SAE/USCAR-2:2022-06 (p. 5.4.6) SAE/USCAR-2:2024-12 (p. 5.4.6) VW 80332:2017-09 (PG 17) VW 80332:2019-01 (PG 17) VW 80332:2021-02 (PG 17) VW 80332:2024-01 (TG 17) MBN LV 215:2017-08 (PG 17) A 009 000 04 99:2013-07","test_object_zh":"汽车电气与电子设备的部件/组件"},{"_id":"6a5dc9a9f1c10c8ce8259ea7","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Odporność na środki chemiczne","methodology_en":"Resistance to chemical agents","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na środki chemiczne","reference":"VW 75174:2018-10 (p. B 22.1A; B 22.1B; B 24.1; L 22.1A; L 22.1B; L 24.1) VW 80332:2024-01 (TG 22) LV 214:2010-03 (p. B 22.1A; B 22.1B; B 24.1) GS 95006-7-1:2016-03 (p. B 22.1A; B 22.1B; B 24.1) GS 95006-7-1:2021-11 (p. B 22.1) MBN 10384:2010-11 (p. B 22.1A; B 22.1B; B 24.1) SAE/USCAR-2:2020-02 (p. 5.6.4) SAE/USCAR-2:2022-06 (p. 5.6.4) SAE/USCAR-2:2024-12 (p. 5.6.4) MBN LV 215:2017-08 (PG 22B)","norm_bases":["VW 75174:2018-10 (p. B 22.1A; B 22.1B; B 24.1; L 22.1A; L 22.1B; L 24.1) VW 80332:2024-01 (TG 22) LV 214:2010-03 (p. B 22.1A; B 22.1B; B 24.1) GS 95006-7-1:2016-03 (p. B 22.1A; B 22.1B; B 24.1) GS 95006-7-1:2021-11 (p. B 22.1) MBN 10384:2010-11 (p. B 22.1A; B 22.1B; B 24.1) SAE/USCAR-2:2020-02 (p. 5.6.4) SAE/USCAR-2:2022-06 (p. 5.6.4) SAE/USCAR-2:2024-12 (p. 5.6.4) MBN LV 215:2017-08 (PG 22B)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Odporność na środki chemiczne VW 75174:2018-10 (p. B 22.1A; B 22.1B; B 24.1; L 22.1A; L 22.1B; L 24.1) VW 80332:2024-01 (TG 22) LV 214:2010-03 (p. B 22.1A; B 22.1B; B 24.1) GS 95006-7-1:2016-03 (p. B 22.1A; B 22.1B; B 24.1) GS 95006-7-1:2021-11 (p. B 22.1) MBN 10384:2010-11 (p. B 22.1A; B 22.1B; B 24.1) SAE/USCAR-2:2020-02 (p. 5.6.4) SAE/USCAR-2:2022-06 (p. 5.6.4) SAE/USCAR-2:2024-12 (p. 5.6.4) MBN LV 215:2017-08 (PG 22B) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Odpornosc na srodki chemiczne VW 75174:2018-10 (p. B 22.1A; B 22.1B; B 24.1; L 22.1A; L 22.1B; L 24.1) VW 80332:2024-01 (TG 22) LV 214:2010-03 (p. B 22.1A; B 22.1B; B 24.1) GS 95006-7-1:2016-03 (p. B 22.1A; B 22.1B; B 24.1) GS 95006-7-1:2021-11 (p. B 22.1) MBN 10384:2010-11 (p. B 22.1A; B 22.1B; B 24.1) SAE/USCAR-2:2020-02 (p. 5.6.4) SAE/USCAR-2:2022-06 (p. 5.6.4) SAE/USCAR-2:2024-12 (p. 5.6.4) MBN LV 215:2017-08 (PG 22B)","categories":["electronics"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Resistance to chemical agents VW 75174:2018-10 (p. B 22.1A; B 22.1B; B 24.1; L 22.1A; L 22.1B; L 24.1) VW 80332:2024-01 (TG 22) LV 214:2010-03 (p. B 22.1A; B 22.1B; B 24.1) GS 95006-7-1:2016-03 (p. B 22.1A; B 22.1B; B 24.1) GS 95006-7-1:2021-11 (p. B 22.1) MBN 10384:2010-11 (p. B 22.1A; B 22.1B; B 24.1) SAE/USCAR-2:2020-02 (p. 5.6.4) SAE/USCAR-2:2022-06 (p. 5.6.4) SAE/USCAR-2:2024-12 (p. 5.6.4) MBN LV 215:2017-08 (PG 22B)","search_zh":"汽车电气与电子设备的部件/组件 VW 75174:2018-10 (p. B 22.1A; B 22.1B; B 24.1; L 22.1A; L 22.1B; L 24.1) VW 80332:2024-01 (TG 22) LV 214:2010-03 (p. B 22.1A; B 22.1B; B 24.1) GS 95006-7-1:2016-03 (p. B 22.1A; B 22.1B; B 24.1) GS 95006-7-1:2021-11 (p. B 22.1) MBN 10384:2010-11 (p. B 22.1A; B 22.1B; B 24.1) SAE/USCAR-2:2020-02 (p. 5.6.4) SAE/USCAR-2:2022-06 (p. 5.6.4) SAE/USCAR-2:2024-12 (p. 5.6.4) MBN LV 215:2017-08 (PG 22B)","test_object_zh":"汽车电气与电子设备的部件/组件"},{"_id":"6a5dc9a9f1c10c8ce8259ea8","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Badanie szczelności / zanurzenie przy różnicy ciśnień","methodology_en":"Tightness test / immersion under a pressure difference","parameters":[{"name":"Ciśnienie","range":"0 - 1 bar (± 0,001 bar)"},{"name":"Ciśnienie","range":"1 - 10 bar (± 0,01 bar)"}],"parameters_en":[{"name":"Pressure","range":"0 - 1 bar (± 0,001 bar)"},{"name":"Pressure","range":"1 - 10 bar (± 0,01 bar)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badanie szczelności / zanurzenie przy różnicy ciśnień\nZakres:\nCiśnienie 0 - 1 bar (± 0,001 bar)\nCiśnienie 1 - 10 bar (± 0,01 bar)","reference":"IEC 60512-14-5:2006 | IEC 60068-2-13:1983 VW 75174:2018-10 (p. B 23.1; L 23.1) VW 80332:2024-01 (TG 23) LV 214:2010-03 (p. B 23.1) GS 95006-7-1:2016-03 (p. B 23.1) GS 95006-7-1:2021-11 (p. B 23.3) MBN 10384:2010-11 (p. B 23.1) SAE/USCAR-2:2020-02 (p. 5.6.6) SAE/USCAR-2:2022-06 (p. 5.6.6) SAE/USCAR-2:2024-12 (p. 5.6.6) A 009 000 04 99:2013-07 (p. 3.10: B 23.k1) Scope of accreditation No. AB 1776","norm_bases":["IEC 60512-14-5:2006","IEC 60068-2-13:1983 VW 75174:2018-10 (p. B 23.1; L 23.1) VW 80332:2024-01 (TG 23) LV 214:2010-03 (p. B 23.1) GS 95006-7-1:2016-03 (p. B 23.1) GS 95006-7-1:2021-11 (p. B 23.3) MBN 10384:2010-11 (p. B 23.1) SAE/USCAR-2:2020-02 (p. 5.6.6) SAE/USCAR-2:2022-06 (p. 5.6.6) SAE/USCAR-2:2024-12 (p. 5.6.6) A 009 000 04 99:2013-07 (p. 3.10: B 23.k1) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Badanie szczelności / zanurzenie przy różnicy ciśnień\nZakres:\nCiśnienie 0 - 1 bar (± 0,001 bar)\nCiśnienie 1 - 10 bar (± 0,01 bar) IEC 60512-14-5:2006 | IEC 60068-2-13:1983 VW 75174:2018-10 (p. B 23.1; L 23.1) VW 80332:2024-01 (TG 23) LV 214:2010-03 (p. B 23.1) GS 95006-7-1:2016-03 (p. B 23.1) GS 95006-7-1:2021-11 (p. B 23.3) MBN 10384:2010-11 (p. B 23.1) SAE/USCAR-2:2020-02 (p. 5.6.6) SAE/USCAR-2:2022-06 (p. 5.6.6) SAE/USCAR-2:2024-12 (p. 5.6.6) A 009 000 04 99:2013-07 (p. 3.10: B 23.k1) Scope of accreditation No. AB 1776 Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Badanie szczelnosci / zanurzenie przy roznicy cisnien\nZakres:\nCisnienie 0 - 1 bar (± 0,001 bar)\nCisnienie 1 - 10 bar (± 0,01 bar) IEC 60512-14-5:2006 | IEC 60068-2-13:1983 VW 75174:2018-10 (p. B 23.1; L 23.1) VW 80332:2024-01 (TG 23) LV 214:2010-03 (p. B 23.1) GS 95006-7-1:2016-03 (p. B 23.1) GS 95006-7-1:2021-11 (p. B 23.3) MBN 10384:2010-11 (p. B 23.1) SAE/USCAR-2:2020-02 (p. 5.6.6) SAE/USCAR-2:2022-06 (p. 5.6.6) SAE/USCAR-2:2024-12 (p. 5.6.6) A 009 000 04 99:2013-07 (p. 3.10: B 23.k1) Scope of accreditation No. AB 1776","categories":["electronics"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Tightness test / immersion under a pressure difference Pressure Pressure IEC 60512-14-5:2006 | IEC 60068-2-13:1983 VW 75174:2018-10 (p. B 23.1; L 23.1) VW 80332:2024-01 (TG 23) LV 214:2010-03 (p. B 23.1) GS 95006-7-1:2016-03 (p. B 23.1) GS 95006-7-1:2021-11 (p. B 23.3) MBN 10384:2010-11 (p. B 23.1) SAE/USCAR-2:2020-02 (p. 5.6.6) SAE/USCAR-2:2022-06 (p. 5.6.6) SAE/USCAR-2:2024-12 (p. 5.6.6) A 009 000 04 99:2013-07 (p. 3.10: B 23.k1) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"压力","range":"0 - 1 bar (± 0,001 bar)"},{"name":"压力","range":"1 - 10 bar (± 0,01 bar)"}],"search_zh":"汽车电气与电子设备的部件/组件 压力 压力 IEC 60512-14-5:2006 | IEC 60068-2-13:1983 VW 75174:2018-10 (p. B 23.1; L 23.1) VW 80332:2024-01 (TG 23) LV 214:2010-03 (p. B 23.1) GS 95006-7-1:2016-03 (p. B 23.1) GS 95006-7-1:2021-11 (p. B 23.3) MBN 10384:2010-11 (p. B 23.1) SAE/USCAR-2:2020-02 (p. 5.6.6) SAE/USCAR-2:2022-06 (p. 5.6.6) SAE/USCAR-2:2024-12 (p. 5.6.6) A 009 000 04 99:2013-07 (p. 3.10: B 23.k1) Scope of accreditation No. AB 1776","test_object_zh":"汽车电气与电子设备的部件/组件"},{"_id":"6a5dc9a9f1c10c8ce8259ea9","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Zanurzenie z szokiem termicznym","methodology_en":"Immersion with thermal shock","parameters":[{"name":"Temperatura","range":"do 200 °C (± 2 °C)"},{"name":"Thermal shock immersion Range:"}],"parameters_en":[{"name":"Temperature","range":"do 200 °C (± 2 °C)"},{"name":"Thermal shock immersion Range:"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zanurzenie z szokiem termicznym\nZakres:\nTemperatura do 200 °C (± 2 °C)\nThermal shock immersion Range:","reference":"VW 75174:2018-10 (p. B 23.3; L 23.3) LV 214:2010-03 (p. B 23.3) GS 95006-7-1:2016-03 (p. B 23.3) GS 95006-7-1:2021-11 (p. B 23.5) MBN 10384:2010-11 (p. B 23.3) SAE/USCAR-2:2020-02 (p. 5.6.5) SAE/USCAR-2:2022-06 (p. 5.6.5) SAE/USCAR-2:2024-12 (p. 5.6.5)","norm_bases":["VW 75174:2018-10 (p. B 23.3; L 23.3) LV 214:2010-03 (p. B 23.3) GS 95006-7-1:2016-03 (p. B 23.3) GS 95006-7-1:2021-11 (p. B 23.5) MBN 10384:2010-11 (p. B 23.3) SAE/USCAR-2:2020-02 (p. 5.6.5) SAE/USCAR-2:2022-06 (p. 5.6.5) SAE/USCAR-2:2024-12 (p. 5.6.5)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Zanurzenie z szokiem termicznym\nZakres:\nTemperatura do 200 °C (± 2 °C)\nThermal shock immersion Range: VW 75174:2018-10 (p. B 23.3; L 23.3) LV 214:2010-03 (p. B 23.3) GS 95006-7-1:2016-03 (p. B 23.3) GS 95006-7-1:2021-11 (p. B 23.5) MBN 10384:2010-11 (p. B 23.3) SAE/USCAR-2:2020-02 (p. 5.6.5) SAE/USCAR-2:2022-06 (p. 5.6.5) SAE/USCAR-2:2024-12 (p. 5.6.5) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Zanurzenie z szokiem termicznym\nZakres:\nTemperatura do 200 °C (± 2 °C)\nThermal shock immersion Range: VW 75174:2018-10 (p. B 23.3; L 23.3) LV 214:2010-03 (p. B 23.3) GS 95006-7-1:2016-03 (p. B 23.3) GS 95006-7-1:2021-11 (p. B 23.5) MBN 10384:2010-11 (p. B 23.3) SAE/USCAR-2:2020-02 (p. 5.6.5) SAE/USCAR-2:2022-06 (p. 5.6.5) SAE/USCAR-2:2024-12 (p. 5.6.5)","categories":["electronics"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Immersion with thermal shock Temperature Thermal shock immersion Range: VW 75174:2018-10 (p. B 23.3; L 23.3) LV 214:2010-03 (p. B 23.3) GS 95006-7-1:2016-03 (p. B 23.3) GS 95006-7-1:2021-11 (p. B 23.5) MBN 10384:2010-11 (p. B 23.3) SAE/USCAR-2:2020-02 (p. 5.6.5) SAE/USCAR-2:2022-06 (p. 5.6.5) SAE/USCAR-2:2024-12 (p. 5.6.5)","parameters_zh":[{"name":"温度","range":"do 200 °C (± 2 °C)"},{"name":"Thermal shock immersion Range:"}],"search_zh":"汽车电气与电子设备的部件/组件 温度 VW 75174:2018-10 (p. B 23.3; L 23.3) LV 214:2010-03 (p. B 23.3) GS 95006-7-1:2016-03 (p. B 23.3) GS 95006-7-1:2021-11 (p. B 23.5) MBN 10384:2010-11 (p. B 23.3) SAE/USCAR-2:2020-02 (p. 5.6.5) SAE/USCAR-2:2022-06 (p. 5.6.5) SAE/USCAR-2:2024-12 (p. 5.6.5)","test_object_zh":"汽车电气与电子设备的部件/组件"},{"_id":"6a5dc9a9f1c10c8ce8259eaa","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Badanie szczelności / ochrona przed dostępem pyłu","methodology_en":"Tightness test / protection against ingress of dust","parameters":[],"parameters_en":[],"technique":"Metoda IP5KX, IP6KX","techniques":["Metoda IP5KX, IP6KX"],"technique_en":"IP5KX, IP6KX method","computed":[],"computed_en":[],"activity":"Badanie szczelności / ochrona przed dostępem pyłu\nMetoda IP5KX, IP6KX","reference":"ISO 20653:2013 | ISO 20653:2023 VW 80332:2017-09 (PG 49A) VW 80332:2019-01 (PG 49A) VW 80332:2021-02 (PG 49A) VW 80332:2024-01 (TG 49A)","norm_bases":["ISO 20653:2013","ISO 20653:2023 VW 80332:2017-09 (PG 49A) VW 80332:2019-01 (PG 49A) VW 80332:2021-02 (PG 49A) VW 80332:2024-01 (TG 49A)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Badanie szczelności / ochrona przed dostępem pyłu\nMetoda IP5KX, IP6KX ISO 20653:2013 | ISO 20653:2023 VW 80332:2017-09 (PG 49A) VW 80332:2019-01 (PG 49A) VW 80332:2021-02 (PG 49A) VW 80332:2024-01 (TG 49A) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Badanie szczelnosci / ochrona przed dostepem pylu\nMetoda IP5KX, IP6KX ISO 20653:2013 | ISO 20653:2023 VW 80332:2017-09 (PG 49A) VW 80332:2019-01 (PG 49A) VW 80332:2021-02 (PG 49A) VW 80332:2024-01 (TG 49A)","categories":["electronics"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Tightness test / protection against ingress of dust IP5KX, IP6KX method ISO 20653:2013 | ISO 20653:2023 VW 80332:2017-09 (PG 49A) VW 80332:2019-01 (PG 49A) VW 80332:2021-02 (PG 49A) VW 80332:2024-01 (TG 49A)","search_zh":"汽车电气与电子设备的部件/组件 ISO 20653:2013 | ISO 20653:2023 VW 80332:2017-09 (PG 49A) VW 80332:2019-01 (PG 49A) VW 80332:2021-02 (PG 49A) VW 80332:2024-01 (TG 49A)","test_object_zh":"汽车电气与电子设备的部件/组件"},{"_id":"6a5dc9a9f1c10c8ce8259eab","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Badanie szczelności / ochrona przed dostępem wody, Stopień ochrony: IPX4, IPX4K, IPX9K, IPX6, IPX6K","methodology_en":"Tightness test / protection against ingress of water, Degree of protection: IPX4, IPX4K, IPX9K, IPX6, IPX6K","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badanie szczelności / ochrona przed dostępem wody, Stopień ochrony: IPX4, IPX4K, IPX9K, IPX6, IPX6K","reference":"ISO 20653:2013 | ISO 20653:2023 VW 75174:2018-10 (p. B 23.4; L 23.4) LV 214:2010-03 (p. B 23.4) GS 95006-7-1:2016-03 (p. B 23.4) GS 95006-7-1:2021-11 (p. B 23.8, B 23.6 ) MBN 10384:2010-11 (p. B 23.4) SAE/USCAR-2:2020-02 (p. 5.6.7) SAE/USCAR-2:2022-06 (p. 5.6.7) SAE/USCAR-2:2024-12 (p. 5.6.7)","norm_bases":["ISO 20653:2013","ISO 20653:2023 VW 75174:2018-10 (p. B 23.4; L 23.4) LV 214:2010-03 (p. B 23.4) GS 95006-7-1:2016-03 (p. B 23.4) GS 95006-7-1:2021-11 (p. B 23.8, B 23.6 ) MBN 10384:2010-11 (p. B 23.4) SAE/USCAR-2:2020-02 (p. 5.6.7) SAE/USCAR-2:2022-06 (p. 5.6.7) SAE/USCAR-2:2024-12 (p. 5.6.7)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Badanie szczelności / ochrona przed dostępem wody, Stopień ochrony: IPX4, IPX4K, IPX9K, IPX6, IPX6K ISO 20653:2013 | ISO 20653:2023 VW 75174:2018-10 (p. B 23.4; L 23.4) LV 214:2010-03 (p. B 23.4) GS 95006-7-1:2016-03 (p. B 23.4) GS 95006-7-1:2021-11 (p. B 23.8, B 23.6 ) MBN 10384:2010-11 (p. B 23.4) SAE/USCAR-2:2020-02 (p. 5.6.7) SAE/USCAR-2:2022-06 (p. 5.6.7) SAE/USCAR-2:2024-12 (p. 5.6.7) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Badanie szczelnosci / ochrona przed dostepem wody, Stopien ochrony: IPX4, IPX4K, IPX9K, IPX6, IPX6K ISO 20653:2013 | ISO 20653:2023 VW 75174:2018-10 (p. B 23.4; L 23.4) LV 214:2010-03 (p. B 23.4) GS 95006-7-1:2016-03 (p. B 23.4) GS 95006-7-1:2021-11 (p. B 23.8, B 23.6 ) MBN 10384:2010-11 (p. B 23.4) SAE/USCAR-2:2020-02 (p. 5.6.7) SAE/USCAR-2:2022-06 (p. 5.6.7) SAE/USCAR-2:2024-12 (p. 5.6.7)","categories":["water","electronics"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Tightness test / protection against ingress of water, Degree of protection: IPX4, IPX4K, IPX9K, IPX6, IPX6K ISO 20653:2013 | ISO 20653:2023 VW 75174:2018-10 (p. B 23.4; L 23.4) LV 214:2010-03 (p. B 23.4) GS 95006-7-1:2016-03 (p. B 23.4) GS 95006-7-1:2021-11 (p. B 23.8, B 23.6 ) MBN 10384:2010-11 (p. B 23.4) SAE/USCAR-2:2020-02 (p. 5.6.7) SAE/USCAR-2:2022-06 (p. 5.6.7) SAE/USCAR-2:2024-12 (p. 5.6.7)","search_zh":"汽车电气与电子设备的部件/组件 ISO 20653:2013 | ISO 20653:2023 VW 75174:2018-10 (p. B 23.4; L 23.4) LV 214:2010-03 (p. B 23.4) GS 95006-7-1:2016-03 (p. B 23.4) GS 95006-7-1:2021-11 (p. B 23.8, B 23.6 ) MBN 10384:2010-11 (p. B 23.4) SAE/USCAR-2:2020-02 (p. 5.6.7) SAE/USCAR-2:2022-06 (p. 5.6.7) SAE/USCAR-2:2024-12 (p. 5.6.7)","test_object_zh":"汽车电气与电子设备的部件/组件"},{"_id":"6a5dc9a9f1c10c8ce8259eac","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Dźwięk blokowania / łączenia","methodology_en":"Locking / coupling sound","parameters":[{"name":"Zakres","range":"(5 – 10) kHz (± 1 dB);"},{"name":"Zakres","range":"(3,15 – 20) kHz (± 3 dB)"}],"parameters_en":[{"name":"Range","range":"(5 – 10) kHz (± 1 dB);"},{"name":"Range","range":"(3,15 – 20) kHz (± 3 dB)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Dźwięk blokowania / łączenia\nZakres:\nZakres (5 – 10) kHz (± 1 dB);\nZakres (3,15 – 20) kHz (± 3 dB)","reference":"VW 75174:2018-10 (p. E 28.1; P 28.1) VW 80332:2024-01 (TG 28) LV 214:2010-03 (p. E 28.1) GS 95006-7-1:2016-03 (p. E 28.1) GS 95006-7-1:2021-11 (p. E 28.1) MBN 10384:2010-11 (p. E 28.1) SAE/USCAR-2:2020-02 (p. 5.4.7) SAE/USCAR-2:2022-06 (p. 5.4.7) SAE/USCAR-2:2024-12 (p. 5.4.7)","norm_bases":["VW 75174:2018-10 (p. E 28.1; P 28.1) VW 80332:2024-01 (TG 28) LV 214:2010-03 (p. E 28.1) GS 95006-7-1:2016-03 (p. E 28.1) GS 95006-7-1:2021-11 (p. E 28.1) MBN 10384:2010-11 (p. E 28.1) SAE/USCAR-2:2020-02 (p. 5.4.7) SAE/USCAR-2:2022-06 (p. 5.4.7) SAE/USCAR-2:2024-12 (p. 5.4.7)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Dźwięk blokowania / łączenia\nZakres:\nZakres (5 – 10) kHz (± 1 dB);\nZakres (3,15 – 20) kHz (± 3 dB) VW 75174:2018-10 (p. E 28.1; P 28.1) VW 80332:2024-01 (TG 28) LV 214:2010-03 (p. E 28.1) GS 95006-7-1:2016-03 (p. E 28.1) GS 95006-7-1:2021-11 (p. E 28.1) MBN 10384:2010-11 (p. E 28.1) SAE/USCAR-2:2020-02 (p. 5.4.7) SAE/USCAR-2:2022-06 (p. 5.4.7) SAE/USCAR-2:2024-12 (p. 5.4.7) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Dzwiek blokowania / laczenia\nZakres:\nZakres (5 – 10) kHz (± 1 dB);\nZakres (3,15 – 20) kHz (± 3 dB) VW 75174:2018-10 (p. E 28.1; P 28.1) VW 80332:2024-01 (TG 28) LV 214:2010-03 (p. E 28.1) GS 95006-7-1:2016-03 (p. E 28.1) GS 95006-7-1:2021-11 (p. E 28.1) MBN 10384:2010-11 (p. E 28.1) SAE/USCAR-2:2020-02 (p. 5.4.7) SAE/USCAR-2:2022-06 (p. 5.4.7) SAE/USCAR-2:2024-12 (p. 5.4.7)","categories":["electronics"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Locking / coupling sound Range Range VW 75174:2018-10 (p. E 28.1; P 28.1) VW 80332:2024-01 (TG 28) LV 214:2010-03 (p. E 28.1) GS 95006-7-1:2016-03 (p. E 28.1) GS 95006-7-1:2021-11 (p. E 28.1) MBN 10384:2010-11 (p. E 28.1) SAE/USCAR-2:2020-02 (p. 5.4.7) SAE/USCAR-2:2022-06 (p. 5.4.7) SAE/USCAR-2:2024-12 (p. 5.4.7)","parameters_zh":[{"name":"范围","range":"(5 – 10) kHz (± 1 dB);"},{"name":"范围","range":"(3,15 – 20) kHz (± 3 dB)"}],"search_zh":"汽车电气与电子设备的部件/组件 范围 范围 VW 75174:2018-10 (p. E 28.1; P 28.1) VW 80332:2024-01 (TG 28) LV 214:2010-03 (p. E 28.1) GS 95006-7-1:2016-03 (p. E 28.1) GS 95006-7-1:2021-11 (p. E 28.1) MBN 10384:2010-11 (p. E 28.1) SAE/USCAR-2:2020-02 (p. 5.4.7) SAE/USCAR-2:2022-06 (p. 5.4.7) SAE/USCAR-2:2024-12 (p. 5.4.7)","test_object_zh":"汽车电气与电子设备的部件/组件"},{"_id":"6a5dc9a9f1c10c8ce8259ead","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Ciśnienie pmax wypchnięcia zaślepki","methodology_en":"Pressure pmax for ejection of the blanking plug","parameters":[{"name":"Ciśnienie","range":"(0 - 1) bar ± 0,001 bar"},{"name":"Ciśnienie","range":"(1 - 10) bar ± 0,01 bar"}],"parameters_en":[{"name":"Pressure","range":"(0 - 1) bar ± 0,001 bar"},{"name":"Pressure","range":"(1 - 10) bar ± 0,01 bar"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciśnienie pmax wypchnięcia zaślepki\nZakres:\nCiśnienie (0 - 1) bar ± 0,001 bar\nCiśnienie (1 - 10) bar ± 0,01 bar","reference":"VW 75174:2018-10 (p. E 29.2; P 29.2) LV 214:2010-03 (p. E 29.2) GS 95006-7-1:2016-03 (p. E 29.2) GS 95006-7-1:2021-11 (p. E 29.3) MBN 10384:2010-11 (p. E 29.2)","norm_bases":["VW 75174:2018-10 (p. E 29.2; P 29.2) LV 214:2010-03 (p. E 29.2) GS 95006-7-1:2016-03 (p. E 29.2) GS 95006-7-1:2021-11 (p. E 29.3) MBN 10384:2010-11 (p. E 29.2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Ciśnienie pmax wypchnięcia zaślepki\nZakres:\nCiśnienie (0 - 1) bar ± 0,001 bar\nCiśnienie (1 - 10) bar ± 0,01 bar VW 75174:2018-10 (p. E 29.2; P 29.2) LV 214:2010-03 (p. E 29.2) GS 95006-7-1:2016-03 (p. E 29.2) GS 95006-7-1:2021-11 (p. E 29.3) MBN 10384:2010-11 (p. E 29.2) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Cisnienie pmax wypchniecia zaslepki\nZakres:\nCisnienie (0 - 1) bar ± 0,001 bar\nCisnienie (1 - 10) bar ± 0,01 bar VW 75174:2018-10 (p. E 29.2; P 29.2) LV 214:2010-03 (p. E 29.2) GS 95006-7-1:2016-03 (p. E 29.2) GS 95006-7-1:2021-11 (p. E 29.3) MBN 10384:2010-11 (p. E 29.2)","categories":["electronics"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Pressure pmax for ejection of the blanking plug Pressure Pressure VW 75174:2018-10 (p. E 29.2; P 29.2) LV 214:2010-03 (p. E 29.2) GS 95006-7-1:2016-03 (p. E 29.2) GS 95006-7-1:2021-11 (p. E 29.3) MBN 10384:2010-11 (p. E 29.2)","parameters_zh":[{"name":"压力","range":"(0 - 1) bar ± 0,001 bar"},{"name":"压力","range":"(1 - 10) bar ± 0,01 bar"}],"search_zh":"汽车电气与电子设备的部件/组件 压力 压力 VW 75174:2018-10 (p. E 29.2; P 29.2) LV 214:2010-03 (p. E 29.2) GS 95006-7-1:2016-03 (p. E 29.2) GS 95006-7-1:2021-11 (p. E 29.3) MBN 10384:2010-11 (p. E 29.2)","test_object_zh":"汽车电气与电子设备的部件/组件"},{"_id":"6a5dc9a9f1c10c8ce8259eae","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Badanie odporności na jednostajne zginanie (SMBT)","methodology_en":"Testing of resistance to uniform bending (SMBT)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badanie odporności na jednostajne zginanie (SMBT)","reference":"VW 75174-2:2020-02 VW 60330:2013-12 (p. 5.1.1) GS 95006-7-2:2008-03 MBN 10384-2:2007-12 Scope of accreditation No. AB 1776","norm_bases":["VW 75174-2:2020-02 VW 60330:2013-12 (p. 5.1.1) GS 95006-7-2:2008-03 MBN 10384-2:2007-12 Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Badanie odporności na jednostajne zginanie (SMBT) VW 75174-2:2020-02 VW 60330:2013-12 (p. 5.1.1) GS 95006-7-2:2008-03 MBN 10384-2:2007-12 Scope of accreditation No. AB 1776 Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Badanie odpornosci na jednostajne zginanie (SMBT) VW 75174-2:2020-02 VW 60330:2013-12 (p. 5.1.1) GS 95006-7-2:2008-03 MBN 10384-2:2007-12 Scope of accreditation No. AB 1776","categories":["electronics"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Testing of resistance to uniform bending (SMBT) VW 75174-2:2020-02 VW 60330:2013-12 (p. 5.1.1) GS 95006-7-2:2008-03 MBN 10384-2:2007-12 Scope of accreditation No. AB 1776","search_zh":"汽车电气与电子设备的部件/组件 VW 75174-2:2020-02 VW 60330:2013-12 (p. 5.1.1) GS 95006-7-2:2008-03 MBN 10384-2:2007-12 Scope of accreditation No. AB 1776","test_object_zh":"汽车电气与电子设备的部件/组件"},{"_id":"6a5dc9a9f1c10c8ce8259eaf","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Odporność na cykliczne zmiany środowiska: obojętna mgła solna i warunki klimatyczne.","methodology_en":"Resistance to cyclic environmental changes: neutral salt spray and climatic conditions.","parameters":[{"name":"Temperatura","range":"(16 – 70) °C ± 2 °C"},{"name":"Wilgotność względna:"},{"name":"Zakres","range":"23 °C ± 2 °C / 50 % RH ± 5 % RH"},{"name":"40 °C ± 2 °C / 93 % RH ± 5 % RH 50 °C ± 2 °C / 95 % RH ± 5 % RH 60 °C ± 2 °C / 20 % RH ± 5 % RH"},{"name":"Mgła solna","range":"35 °C ± 2 °C"}],"parameters_en":[{"name":"Temperature","range":"(16 – 70) °C ± 2 °C"},{"name":"Relative humidity:"},{"name":"Range","range":"23 °C ± 2 °C / 50 % RH ± 5 % RH"},{"name":"40 °C ± 2 °C / 93 % RH ± 5 % RH 50 °C ± 2 °C / 95 % RH ± 5 % RH 60 °C ± 2 °C / 20 % RH ± 5 % RH"},{"name":"Salt spray","range":"35 °C ± 2 °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na cykliczne zmiany środowiska: obojętna mgła solna i warunki klimatyczne.\nZakres:\nTemperatura (16 – 70) °C ± 2 °C\nWilgotność względna:\nZakres 23 °C ± 2 °C / 50 % RH ± 5 % RH\n40 °C ± 2 °C / 93 % RH ± 5 % RH 50 °C ± 2 °C / 95 % RH ± 5 % RH 60 °C ± 2 °C / 20 % RH ± 5 % RH\nMgła solna 35 °C ± 2 °C","reference":"IEC 60068-2-52:2017 | IEC 60068-2-52:1996 | ISO 9227:2017-03 (z wyłączeniem punktów 5.2.3 i 5.2.4) | ISO 9227:2022-11 (z wyłączeniem punktów 5.2.3 i 5.2.4) VW 75174:2018-10 (p. B 18.2; B 18.3; L 18.2; L 18.3) VW 80332:2024-01 (TG 18C) LV 214:2010-03 (p. B 18.2; B 18.3) GS 95006-7-1:2016-03 (p. B 18.2; B 18.3) GS 95006-7-1:2021-11(p. B 18.2; B 18.3) MBN 10384:2010-11 (p. B 18.2) MBN LV 215:2017-08 (p. PG 18C) A 009 000 04 99:2013-07 (p. 3.9)","norm_bases":["IEC 60068-2-52:2017","IEC 60068-2-52:1996","ISO 9227:2017-03 (z wyłączeniem punktów 5.2.3 i 5.2.4)","ISO 9227:2022-11 (z wyłączeniem punktów 5.2.3 i 5.2.4) VW 75174:2018-10 (p. B 18.2; B 18.3; L 18.2; L 18.3) VW 80332:2024-01 (TG 18C) LV 214:2010-03 (p. B 18.2; B 18.3) GS 95006-7-1:2016-03 (p. B 18.2; B 18.3) GS 95006-7-1:2021-11(p. B 18.2; B 18.3) MBN 10384:2010-11 (p. B 18.2) MBN LV 215:2017-08 (p. PG 18C) A 009 000 04 99:2013-07 (p. 3.9)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Odporność na cykliczne zmiany środowiska: obojętna mgła solna i warunki klimatyczne.\nZakres:\nTemperatura (16 – 70) °C ± 2 °C\nWilgotność względna:\nZakres 23 °C ± 2 °C / 50 % RH ± 5 % RH\n40 °C ± 2 °C / 93 % RH ± 5 % RH 50 °C ± 2 °C / 95 % RH ± 5 % RH 60 °C ± 2 °C / 20 % RH ± 5 % RH\nMgła solna 35 °C ± 2 °C IEC 60068-2-52:2017 | IEC 60068-2-52:1996 | ISO 9227:2017-03 (z wyłączeniem punktów 5.2.3 i 5.2.4) | ISO 9227:2022-11 (z wyłączeniem punktów 5.2.3 i 5.2.4) VW 75174:2018-10 (p. B 18.2; B 18.3; L 18.2; L 18.3) VW 80332:2024-01 (TG 18C) LV 214:2010-03 (p. B 18.2; B 18.3) GS 95006-7-1:2016-03 (p. B 18.2; B 18.3) GS 95006-7-1:2021-11(p. B 18.2; B 18.3) MBN 10384:2010-11 (p. B 18.2) MBN LV 215:2017-08 (p. PG 18C) A 009 000 04 99:2013-07 (p. 3.9) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Odpornosc na cykliczne zmiany srodowiska: obojetna mgla solna i warunki klimatyczne.\nZakres:\nTemperatura (16 – 70) °C ± 2 °C\nWilgotnosc wzgledna:\nZakres 23 °C ± 2 °C / 50 % RH ± 5 % RH\n40 °C ± 2 °C / 93 % RH ± 5 % RH 50 °C ± 2 °C / 95 % RH ± 5 % RH 60 °C ± 2 °C / 20 % RH ± 5 % RH\nMgla solna 35 °C ± 2 °C IEC 60068-2-52:2017 | IEC 60068-2-52:1996 | ISO 9227:2017-03 (z wylaczeniem punktow 5.2.3 i 5.2.4) | ISO 9227:2022-11 (z wylaczeniem punktow 5.2.3 i 5.2.4) VW 75174:2018-10 (p. B 18.2; B 18.3; L 18.2; L 18.3) VW 80332:2024-01 (TG 18C) LV 214:2010-03 (p. B 18.2; B 18.3) GS 95006-7-1:2016-03 (p. B 18.2; B 18.3) GS 95006-7-1:2021-11(p. B 18.2; B 18.3) MBN 10384:2010-11 (p. B 18.2) MBN LV 215:2017-08 (p. PG 18C) A 009 000 04 99:2013-07 (p. 3.9)","categories":["environment","electronics"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Resistance to cyclic environmental changes: neutral salt spray and climatic conditions. Temperature Relative humidity: Range 40 °C ± 2 °C / 93 % RH ± 5 % RH 50 °C ± 2 °C / 95 % RH ± 5 % RH 60 °C ± 2 °C / 20 % RH ± 5 % RH Salt spray IEC 60068-2-52:2017 | IEC 60068-2-52:1996 | ISO 9227:2017-03 (z wyłączeniem punktów 5.2.3 i 5.2.4) | ISO 9227:2022-11 (z wyłączeniem punktów 5.2.3 i 5.2.4) VW 75174:2018-10 (p. B 18.2; B 18.3; L 18.2; L 18.3) VW 80332:2024-01 (TG 18C) LV 214:2010-03 (p. B 18.2; B 18.3) GS 95006-7-1:2016-03 (p. B 18.2; B 18.3) GS 95006-7-1:2021-11(p. B 18.2; B 18.3) MBN 10384:2010-11 (p. B 18.2) MBN LV 215:2017-08 (p. PG 18C) A 009 000 04 99:2013-07 (p. 3.9)","parameters_zh":[{"name":"温度","range":"(16 – 70) °C ± 2 °C"},{"name":"Wilgotność względna:"},{"name":"范围","range":"23 °C ± 2 °C / 50 % RH ± 5 % RH"},{"name":"40 °C ± 2 °C / 93 % RH ± 5 % RH 50 °C ± 2 °C / 95 % RH ± 5 % RH 60 °C ± 2 °C / 20 % RH ± 5 % RH"},{"name":"Mgła solna","range":"35 °C ± 2 °C"}],"search_zh":"汽车电气与电子设备的部件/组件 温度 范围 IEC 60068-2-52:2017 | IEC 60068-2-52:1996 | ISO 9227:2017-03 (z wyłączeniem punktów 5.2.3 i 5.2.4) | ISO 9227:2022-11 (z wyłączeniem punktów 5.2.3 i 5.2.4) VW 75174:2018-10 (p. B 18.2; B 18.3; L 18.2; L 18.3) VW 80332:2024-01 (TG 18C) LV 214:2010-03 (p. B 18.2; B 18.3) GS 95006-7-1:2016-03 (p. B 18.2; B 18.3) GS 95006-7-1:2021-11(p. B 18.2; B 18.3) MBN 10384:2010-11 (p. B 18.2) MBN LV 215:2017-08 (p. PG 18C) A 009 000 04 99:2013-07 (p. 3.9)","test_object_zh":"汽车电气与电子设备的部件/组件"},{"_id":"6a5dc9a9f1c10c8ce8259eb0","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Badania integralności sygnałów","methodology_en":"Signal integrity tests","parameters":[{"name":"Straty wtrąceniowe"},{"name":"Straty wtrąceniowe (tryb wspólny)"},{"name":"Częstotliwość","range":"1 MHz - 20 GHz"}],"parameters_en":[{"name":"Insertion loss"},{"name":"Insertion loss (common mode)"},{"name":"Frequency","range":"1 MHz - 20 GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania integralności sygnałów\nZakres:\nStraty wtrąceniowe\nStraty wtrąceniowe (tryb wspólny)\nCzęstotliwość 1 MHz - 20 GHz","reference":"1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) | EN 50289-1-8 (p. 4.3 (Method C) only) LAH.85E.035.D:2022-08 (p. 6.5.5.2.1 E-01) LAH.V03.825.E:2023-02 (p. 6.5.1 E-08) VW 75206-1:2020-11 (p. 6.2) LAH.V03.825:2020-02 (p. 6.5.1.3 E-01) LAH.V03.825.E:2023-02 (p. 6.5.1 E-01)","norm_bases":["1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2)","EN 50289-1-8 (p. 4.3 (Method C) only) LAH.85E.035.D:2022-08 (p. 6.5.5.2.1 E-01) LAH.V03.825.E:2023-02 (p. 6.5.1 E-08) VW 75206-1:2020-11 (p. 6.2) LAH.V03.825:2020-02 (p. 6.5.1.3 E-01) LAH.V03.825.E:2023-02 (p. 6.5.1 E-01)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Badania integralności sygnałów\nZakres:\nStraty wtrąceniowe\nStraty wtrąceniowe (tryb wspólny)\nCzęstotliwość 1 MHz - 20 GHz 1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) | EN 50289-1-8 (p. 4.3 (Method C) only) LAH.85E.035.D:2022-08 (p. 6.5.5.2.1 E-01) LAH.V03.825.E:2023-02 (p. 6.5.1 E-08) VW 75206-1:2020-11 (p. 6.2) LAH.V03.825:2020-02 (p. 6.5.1.3 E-01) LAH.V03.825.E:2023-02 (p. 6.5.1 E-01) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Badania integralnosci sygnalow\nZakres:\nStraty wtraceniowe\nStraty wtraceniowe (tryb wspolny)\nCzestotliwosc 1 MHz - 20 GHz 1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) | EN 50289-1-8 (p. 4.3 (Method C) only) LAH.85E.035.D:2022-08 (p. 6.5.5.2.1 E-01) LAH.V03.825.E:2023-02 (p. 6.5.1 E-08) VW 75206-1:2020-11 (p. 6.2) LAH.V03.825:2020-02 (p. 6.5.1.3 E-01) LAH.V03.825.E:2023-02 (p. 6.5.1 E-01)","categories":["electronics"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Signal integrity tests Insertion loss Insertion loss (common mode) Frequency 1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) | EN 50289-1-8 (p. 4.3 (Method C) only) LAH.85E.035.D:2022-08 (p. 6.5.5.2.1 E-01) LAH.V03.825.E:2023-02 (p. 6.5.1 E-08) VW 75206-1:2020-11 (p. 6.2) LAH.V03.825:2020-02 (p. 6.5.1.3 E-01) LAH.V03.825.E:2023-02 (p. 6.5.1 E-01)","parameters_zh":[{"name":"Straty wtrąceniowe"},{"name":"Straty wtrąceniowe (tryb wspólny)"},{"name":"频率","range":"1 MHz - 20 GHz"}],"search_zh":"汽车电气与电子设备的部件/组件 信号完整性检验 频率 1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) | EN 50289-1-8 (p. 4.3 (Method C) only) LAH.85E.035.D:2022-08 (p. 6.5.5.2.1 E-01) LAH.V03.825.E:2023-02 (p. 6.5.1 E-08) VW 75206-1:2020-11 (p. 6.2) LAH.V03.825:2020-02 (p. 6.5.1.3 E-01) LAH.V03.825.E:2023-02 (p. 6.5.1 E-01)","test_object_zh":"汽车电气与电子设备的部件/组件","methodology_zh":"信号完整性检验"},{"_id":"6a5dc9a9f1c10c8ce8259eb1","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Badania integralności sygnałów","methodology_en":"Signal integrity tests","parameters":[{"name":"Straty odbiciowe (bramkowane)"},{"name":"Straty odbiciowe (niebramkowane)"},{"name":"Straty odbiciowe (relatywne)"},{"name":"Straty odbiciowe (bezwzględne)"},{"name":"Częstotliwość","range":"1 MHz - 20 GHz"}],"parameters_en":[{"name":"Return loss (gated)"},{"name":"Return loss (ungated)"},{"name":"Return loss (relative)"},{"name":"Return loss (absolute)"},{"name":"Frequency","range":"1 MHz - 20 GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania integralności sygnałów\nZakres:\nStraty odbiciowe (bramkowane)\nStraty odbiciowe (niebramkowane)\nStraty odbiciowe (relatywne)\nStraty odbiciowe (bezwzględne)\nCzęstotliwość 1 MHz - 20 GHz","reference":"LAH.V03.825:2020-02 (p. 6.5.1.4.1 E-02) LAH.V03.825:2020-02 (p. 6.5.1.4.2 E-03) | EN 50289-1-11:2016 (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) VW 75206-2:2022-09 (p. 12.9) LAH.85E.035.D:2022-08 (p. 6.5.5.2.1 E-02b) LAH.V03.825.E:2023-02 (p. 6.5.1 E-02) LAH.85E.035.D:2022-08 (p. 6.5.5.2.1 E-02a) LAH.85E.035.B:2021-11 (Measurement setup RF parameters reflection) Scope of accreditation No. AB 1776","norm_bases":["LAH.V03.825:2020-02 (p. 6.5.1.4.1 E-02) LAH.V03.825:2020-02 (p. 6.5.1.4.2 E-03)","EN 50289-1-11:2016 (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) VW 75206-2:2022-09 (p. 12.9) LAH.85E.035.D:2022-08 (p. 6.5.5.2.1 E-02b) LAH.V03.825.E:2023-02 (p. 6.5.1 E-02) LAH.85E.035.D:2022-08 (p. 6.5.5.2.1 E-02a) LAH.85E.035.B:2021-11 (Measurement setup RF parameters reflection) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Badania integralności sygnałów\nZakres:\nStraty odbiciowe (bramkowane)\nStraty odbiciowe (niebramkowane)\nStraty odbiciowe (relatywne)\nStraty odbiciowe (bezwzględne)\nCzęstotliwość 1 MHz - 20 GHz LAH.V03.825:2020-02 (p. 6.5.1.4.1 E-02) LAH.V03.825:2020-02 (p. 6.5.1.4.2 E-03) | EN 50289-1-11:2016 (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) VW 75206-2:2022-09 (p. 12.9) LAH.85E.035.D:2022-08 (p. 6.5.5.2.1 E-02b) LAH.V03.825.E:2023-02 (p. 6.5.1 E-02) LAH.85E.035.D:2022-08 (p. 6.5.5.2.1 E-02a) LAH.85E.035.B:2021-11 (Measurement setup RF parameters reflection) Scope of accreditation No. AB 1776 Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Badania integralnosci sygnalow\nZakres:\nStraty odbiciowe (bramkowane)\nStraty odbiciowe (niebramkowane)\nStraty odbiciowe (relatywne)\nStraty odbiciowe (bezwzgledne)\nCzestotliwosc 1 MHz - 20 GHz LAH.V03.825:2020-02 (p. 6.5.1.4.1 E-02) LAH.V03.825:2020-02 (p. 6.5.1.4.2 E-03) | EN 50289-1-11:2016 (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) VW 75206-2:2022-09 (p. 12.9) LAH.85E.035.D:2022-08 (p. 6.5.5.2.1 E-02b) LAH.V03.825.E:2023-02 (p. 6.5.1 E-02) LAH.85E.035.D:2022-08 (p. 6.5.5.2.1 E-02a) LAH.85E.035.B:2021-11 (Measurement setup RF parameters reflection) Scope of accreditation No. AB 1776","categories":["electronics"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Signal integrity tests Return loss (gated) Return loss (ungated) Return loss (relative) Return loss (absolute) Frequency LAH.V03.825:2020-02 (p. 6.5.1.4.1 E-02) LAH.V03.825:2020-02 (p. 6.5.1.4.2 E-03) | EN 50289-1-11:2016 (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) VW 75206-2:2022-09 (p. 12.9) LAH.85E.035.D:2022-08 (p. 6.5.5.2.1 E-02b) LAH.V03.825.E:2023-02 (p. 6.5.1 E-02) LAH.85E.035.D:2022-08 (p. 6.5.5.2.1 E-02a) LAH.85E.035.B:2021-11 (Measurement setup RF parameters reflection) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"Straty odbiciowe (bramkowane)"},{"name":"Straty odbiciowe (niebramkowane)"},{"name":"Straty odbiciowe (relatywne)"},{"name":"Straty odbiciowe (bezwzględne)"},{"name":"频率","range":"1 MHz - 20 GHz"}],"search_zh":"汽车电气与电子设备的部件/组件 信号完整性检验 频率 LAH.V03.825:2020-02 (p. 6.5.1.4.1 E-02) LAH.V03.825:2020-02 (p. 6.5.1.4.2 E-03) | EN 50289-1-11:2016 (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) VW 75206-2:2022-09 (p. 12.9) LAH.85E.035.D:2022-08 (p. 6.5.5.2.1 E-02b) LAH.V03.825.E:2023-02 (p. 6.5.1 E-02) LAH.85E.035.D:2022-08 (p. 6.5.5.2.1 E-02a) LAH.85E.035.B:2021-11 (Measurement setup RF parameters reflection) Scope of accreditation No. AB 1776","test_object_zh":"汽车电气与电子设备的部件/组件","methodology_zh":"信号完整性检验"},{"_id":"6a5dc9a9f1c10c8ce8259eb2","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Badania integralności sygnałów","methodology_en":"Signal integrity tests","parameters":[{"name":"Konwersja trybu sygnału: Tłumienie konwersji podłużnej"},{"name":"Tłumienie transferu konwersji podłużnej"},{"name":"Częstotliwość","range":"1 MHz - 1 GHz"}],"parameters_en":[{"name":"Signal mode conversion: Longitudinal conversion loss"},{"name":"Longitudinal conversion transfer loss"},{"name":"Frequency","range":"1 MHz - 1 GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania integralności sygnałów\nZakres:\nKonwersja trybu sygnału: Tłumienie konwersji podłużnej\nTłumienie transferu konwersji podłużnej\nCzęstotliwość 1 MHz - 1 GHz","reference":"1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) LAH.V03.825.E:2023-02 (p. 6.5.1 E-03)","norm_bases":["1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) LAH.V03.825.E:2023-02 (p. 6.5.1 E-03)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Badania integralności sygnałów\nZakres:\nKonwersja trybu sygnału: Tłumienie konwersji podłużnej\nTłumienie transferu konwersji podłużnej\nCzęstotliwość 1 MHz - 1 GHz 1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) LAH.V03.825.E:2023-02 (p. 6.5.1 E-03) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Badania integralnosci sygnalow\nZakres:\nKonwersja trybu sygnalu: Tlumienie konwersji podluznej\nTlumienie transferu konwersji podluznej\nCzestotliwosc 1 MHz - 1 GHz 1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) LAH.V03.825.E:2023-02 (p. 6.5.1 E-03)","categories":["electronics"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Signal integrity tests Signal mode conversion: Longitudinal conversion loss Longitudinal conversion transfer loss Frequency 1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) LAH.V03.825.E:2023-02 (p. 6.5.1 E-03)","parameters_zh":[{"name":"Konwersja trybu sygnału: Tłumienie konwersji podłużnej"},{"name":"Tłumienie transferu konwersji podłużnej"},{"name":"频率","range":"1 MHz - 1 GHz"}],"search_zh":"汽车电气与电子设备的部件/组件 信号完整性检验 频率 1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) LAH.V03.825.E:2023-02 (p. 6.5.1 E-03)","test_object_zh":"汽车电气与电子设备的部件/组件","methodology_zh":"信号完整性检验"},{"_id":"6a5dc9a9f1c10c8ce8259eb3","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Badania integralności sygnałów","methodology_en":"Signal integrity tests","parameters":[{"name":"Opóźnienie propagacji"},{"name":"Częstotliwość","range":"1 MHz - 1 GHz"}],"parameters_en":[{"name":"Propagation delay"},{"name":"Frequency","range":"1 MHz - 1 GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania integralności sygnałów\nZakres:\nOpóźnienie propagacji\nCzęstotliwość 1 MHz - 1 GHz","reference":"1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) LAH.V03.825.E:2023-02 (p. 6.5.1 E-04)","norm_bases":["1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) LAH.V03.825.E:2023-02 (p. 6.5.1 E-04)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Badania integralności sygnałów\nZakres:\nOpóźnienie propagacji\nCzęstotliwość 1 MHz - 1 GHz 1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) LAH.V03.825.E:2023-02 (p. 6.5.1 E-04) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Badania integralnosci sygnalow\nZakres:\nOpoznienie propagacji\nCzestotliwosc 1 MHz - 1 GHz 1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) LAH.V03.825.E:2023-02 (p. 6.5.1 E-04)","categories":["electronics"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Signal integrity tests Propagation delay Frequency 1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) LAH.V03.825.E:2023-02 (p. 6.5.1 E-04)","parameters_zh":[{"name":"Opóźnienie propagacji"},{"name":"频率","range":"1 MHz - 1 GHz"}],"search_zh":"汽车电气与电子设备的部件/组件 信号完整性检验 频率 1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) LAH.V03.825.E:2023-02 (p. 6.5.1 E-04)","test_object_zh":"汽车电气与电子设备的部件/组件","methodology_zh":"信号完整性检验"},{"_id":"6a5dc9a9f1c10c8ce8259eb4","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Badania integralności sygnałów","methodology_en":"Signal integrity tests","parameters":[{"name":"Impedancja charakterystyczna w trybie różnicowym"},{"name":"Częstotliwość","range":"1 MHz - 2 GHz"}],"parameters_en":[{"name":"Characteristic impedance in differential mode"},{"name":"Frequency","range":"1 MHz - 2 GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania integralności sygnałów\nZakres:\nImpedancja charakterystyczna w trybie różnicowym\nCzęstotliwość 1 MHz - 2 GHz","reference":"1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) LAH.V03.825.E:2023-02 (p. 6.5.1 E-05a) LAH.V03.825.E:2023-02 (p. 6.5.1 E-05b)","norm_bases":["1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) LAH.V03.825.E:2023-02 (p. 6.5.1 E-05a) LAH.V03.825.E:2023-02 (p. 6.5.1 E-05b)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Badania integralności sygnałów\nZakres:\nImpedancja charakterystyczna w trybie różnicowym\nCzęstotliwość 1 MHz - 2 GHz 1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) LAH.V03.825.E:2023-02 (p. 6.5.1 E-05a) LAH.V03.825.E:2023-02 (p. 6.5.1 E-05b) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Badania integralnosci sygnalow\nZakres:\nImpedancja charakterystyczna w trybie roznicowym\nCzestotliwosc 1 MHz - 2 GHz 1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) LAH.V03.825.E:2023-02 (p. 6.5.1 E-05a) LAH.V03.825.E:2023-02 (p. 6.5.1 E-05b)","categories":["electronics"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Signal integrity tests Characteristic impedance in differential mode Frequency 1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) LAH.V03.825.E:2023-02 (p. 6.5.1 E-05a) LAH.V03.825.E:2023-02 (p. 6.5.1 E-05b)","parameters_zh":[{"name":"Impedancja charakterystyczna w trybie różnicowym"},{"name":"频率","range":"1 MHz - 2 GHz"}],"search_zh":"汽车电气与电子设备的部件/组件 信号完整性检验 频率 1000BASE-T1 Link Segment Type A ver. 2.3 (UTP) (p. 5.2) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2) LAH.V03.825.E:2023-02 (p. 6.5.1 E-05a) LAH.V03.825.E:2023-02 (p. 6.5.1 E-05b)","test_object_zh":"汽车电气与电子设备的部件/组件","methodology_zh":"信号完整性检验"},{"_id":"6a5dc9a9f1c10c8ce8259eb5","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów","test_object_en":"Components/assemblies of automotive electrical and electronic equipment","methodology":"Badania kompatybilności elektromagnetycznej","methodology_en":"Electromagnetic compatibility testing","parameters":[{"name":"Tłumienność ekranowania"},{"name":"Tłumienność sprzężeniowa"},{"name":"Częstotliwość","range":"30 MHz - 7,5 GHz"},{"name":"Electromagnetic Compatibility (EMC)"}],"parameters_en":[{"name":"Screening attenuation"},{"name":"Coupling attenuation"},{"name":"Frequency","range":"30 MHz - 7,5 GHz"},{"name":"Electromagnetic Compatibility (EMC)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania kompatybilności elektromagnetycznej\nZakres:\nTłumienność ekranowania\nTłumienność sprzężeniowa\nCzęstotliwość 30 MHz - 7,5 GHz\nElectromagnetic Compatibility (EMC)","reference":"IEC 62153-4-4:2015 Ed.02 | IEC 62153-4-7 Ed. 3.0 b:2021 | IEC 62153-4-15 Ed. 2.0 b:20211000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.1.3) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2.4) LAH.85E.035.D:2022-08 (p. 6.5.5.2.2 E-03) LAH.V03.825:2020-02 (p. 6.5.1.5 E-04) LAH.85E.035.B:2021-11 (Recording of the RF parameters shielding and coupling attenuation) LAH.V03.825.E:2023-02 (p. 6.5.1 E-08)","norm_bases":["IEC 62153-4-4:2015 Ed.02","IEC 62153-4-7 Ed. 3.0 b:2021","IEC 62153-4-15 Ed. 2.0 b:20211000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.1.3) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2.4) LAH.85E.035.D:2022-08 (p. 6.5.5.2.2 E-03) LAH.V03.825:2020-02 (p. 6.5.1.5 E-04) LAH.85E.035.B:2021-11 (Recording of the RF parameters shielding and coupling attenuation) LAH.V03.825.E:2023-02 (p. 6.5.1 E-08)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elementy/zespoły wyposażenia elektrycznego i elektronicznego samochodów Badania kompatybilności elektromagnetycznej\nZakres:\nTłumienność ekranowania\nTłumienność sprzężeniowa\nCzęstotliwość 30 MHz - 7,5 GHz\nElectromagnetic Compatibility (EMC) IEC 62153-4-4:2015 Ed.02 | IEC 62153-4-7 Ed. 3.0 b:2021 | IEC 62153-4-15 Ed. 2.0 b:20211000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.1.3) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2.4) LAH.85E.035.D:2022-08 (p. 6.5.5.2.2 E-03) LAH.V03.825:2020-02 (p. 6.5.1.5 E-04) LAH.85E.035.B:2021-11 (Recording of the RF parameters shielding and coupling attenuation) LAH.V03.825.E:2023-02 (p. 6.5.1 E-08) Elementy/zespoly wyposazenia elektrycznego i elektronicznego samochodow Badania kompatybilnosci elektromagnetycznej\nZakres:\nTlumiennosc ekranowania\nTlumiennosc sprzezeniowa\nCzestotliwosc 30 MHz - 7,5 GHz\nElectromagnetic Compatibility (EMC) IEC 62153-4-4:2015 Ed.02 | IEC 62153-4-7 Ed. 3.0 b:2021 | IEC 62153-4-15 Ed. 2.0 b:20211000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.1.3) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2.4) LAH.85E.035.D:2022-08 (p. 6.5.5.2.2 E-03) LAH.V03.825:2020-02 (p. 6.5.1.5 E-04) LAH.85E.035.B:2021-11 (Recording of the RF parameters shielding and coupling attenuation) LAH.V03.825.E:2023-02 (p. 6.5.1 E-08)","categories":["electronics"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Components/assemblies of automotive electrical and electronic equipment Electromagnetic compatibility testing Screening attenuation Coupling attenuation Frequency Electromagnetic Compatibility (EMC) IEC 62153-4-4:2015 Ed.02 | IEC 62153-4-7 Ed. 3.0 b:2021 | IEC 62153-4-15 Ed. 2.0 b:20211000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.1.3) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2.4) LAH.85E.035.D:2022-08 (p. 6.5.5.2.2 E-03) LAH.V03.825:2020-02 (p. 6.5.1.5 E-04) LAH.85E.035.B:2021-11 (Recording of the RF parameters shielding and coupling attenuation) LAH.V03.825.E:2023-02 (p. 6.5.1 E-08)","parameters_zh":[{"name":"Tłumienność ekranowania"},{"name":"Tłumienność sprzężeniowa"},{"name":"频率","range":"30 MHz - 7,5 GHz"},{"name":"电磁兼容（EMC）/ Electromagnetic Compatibility (EMC)"}],"search_zh":"汽车电气与电子设备的部件/组件 电磁兼容检验 频率 电磁兼容（EMC）/ Electromagnetic Compatibility (EMC) IEC 62153-4-4:2015 Ed.02 | IEC 62153-4-7 Ed. 3.0 b:2021 | IEC 62153-4-15 Ed. 2.0 b:20211000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.1.3) 1000BASE-T1 Link Segment Type A ver. 2.0 (STP) (p. 5.2.4) LAH.85E.035.D:2022-08 (p. 6.5.5.2.2 E-03) LAH.V03.825:2020-02 (p. 6.5.1.5 E-04) LAH.85E.035.B:2021-11 (Recording of the RF parameters shielding and coupling attenuation) LAH.V03.825.E:2023-02 (p. 6.5.1 E-08)","test_object_zh":"汽车电气与电子设备的部件/组件","methodology_zh":"电磁兼容检验"},{"_id":"6a5dc9a9f1c10c8ce8259eb6","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Badania integralności sygnałów","methodology_en":"Signal integrity tests","parameters":[{"name":"Straty wtrąceniowe"},{"name":"Częstotliwość","range":"100 kHz - 6000 MHz s"}],"parameters_en":[{"name":"Insertion loss"},{"name":"Frequency","range":"100 kHz - 6000 MHz s"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania integralności sygnałów\nZakres:\nStraty wtrąceniowe\nCzęstotliwość 100 kHz - 6000 MHz s","reference":"EN 50289-1-8:2017 (z wyłączeniem par. 4.1, 4.4) VW 75206-1:2020-11 (par. 6.2) VW 75206-2:2022-09 (p. 12.4) Scope of accreditation No. AB 1776","norm_bases":["EN 50289-1-8:2017 (z wyłączeniem par. 4.1, 4.4) VW 75206-1:2020-11 (par. 6.2) VW 75206-2:2022-09 (p. 12.4) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Badania integralności sygnałów\nZakres:\nStraty wtrąceniowe\nCzęstotliwość 100 kHz - 6000 MHz s EN 50289-1-8:2017 (z wyłączeniem par. 4.1, 4.4) VW 75206-1:2020-11 (par. 6.2) VW 75206-2:2022-09 (p. 12.4) Scope of accreditation No. AB 1776 Kable, Cables Badania integralnosci sygnalow\nZakres:\nStraty wtraceniowe\nCzestotliwosc 100 kHz - 6000 MHz s EN 50289-1-8:2017 (z wylaczeniem par. 4.1, 4.4) VW 75206-1:2020-11 (par. 6.2) VW 75206-2:2022-09 (p. 12.4) Scope of accreditation No. AB 1776","categories":["other"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Signal integrity tests Insertion loss Frequency EN 50289-1-8:2017 (z wyłączeniem par. 4.1, 4.4) VW 75206-1:2020-11 (par. 6.2) VW 75206-2:2022-09 (p. 12.4) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"Straty wtrąceniowe"},{"name":"频率","range":"100 kHz - 6000 MHz s"}],"search_zh":"电缆 信号完整性检验 频率 EN 50289-1-8:2017 (z wyłączeniem par. 4.1, 4.4) VW 75206-1:2020-11 (par. 6.2) VW 75206-2:2022-09 (p. 12.4) Scope of accreditation No. AB 1776","test_object_zh":"电缆","methodology_zh":"信号完整性检验"},{"_id":"6a5dc9a9f1c10c8ce8259eb7","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Pomiar pojemności elektrycznej, indukcyjności jednostkowej","methodology_en":"Measurement of capacitance, unit inductance","parameters":[{"name":"Pojemność"},{"name":"Pojemność efektywna"},{"name":"Pojemność magistrali"},{"name":"Pojemność jednostkowa"},{"name":"Pojemność niesymetryczna"},{"name":"Częstotliwość: 1 kHz"}],"parameters_en":[{"name":"Capacity"},{"name":"Effective capacitance"},{"name":"Bus capacitance"},{"name":"Capacitance per unit length"},{"name":"Unbalanced capacitance"},{"name":"Frequency: 1 kHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pomiar pojemności elektrycznej, indukcyjności jednostkowej\nZakres:\nPojemność\nPojemność efektywna\nPojemność magistrali\nPojemność jednostkowa\nPojemność niesymetryczna\nCzęstotliwość: 1 kHz","reference":"ISO 4141-1:2019 (p. 6.3) | EN 50289-1-5:2001 VW 75206-1:2020-11 (p. 6.3.1) VW 75206-2:2022-09 (p. 11.4.2, 11.4.3, 11.6)","norm_bases":["ISO 4141-1:2019 (p. 6.3)","EN 50289-1-5:2001 VW 75206-1:2020-11 (p. 6.3.1) VW 75206-2:2022-09 (p. 11.4.2, 11.4.3, 11.6)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Pomiar pojemności elektrycznej, indukcyjności jednostkowej\nZakres:\nPojemność\nPojemność efektywna\nPojemność magistrali\nPojemność jednostkowa\nPojemność niesymetryczna\nCzęstotliwość: 1 kHz ISO 4141-1:2019 (p. 6.3) | EN 50289-1-5:2001 VW 75206-1:2020-11 (p. 6.3.1) VW 75206-2:2022-09 (p. 11.4.2, 11.4.3, 11.6) Kable, Cables Pomiar pojemnosci elektrycznej, indukcyjnosci jednostkowej\nZakres:\nPojemnosc\nPojemnosc efektywna\nPojemnosc magistrali\nPojemnosc jednostkowa\nPojemnosc niesymetryczna\nCzestotliwosc: 1 kHz ISO 4141-1:2019 (p. 6.3) | EN 50289-1-5:2001 VW 75206-1:2020-11 (p. 6.3.1) VW 75206-2:2022-09 (p. 11.4.2, 11.4.3, 11.6)","categories":["other"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Measurement of capacitance, unit inductance Capacity Effective capacitance Bus capacitance Capacitance per unit length Unbalanced capacitance Frequency: 1 kHz ISO 4141-1:2019 (p. 6.3) | EN 50289-1-5:2001 VW 75206-1:2020-11 (p. 6.3.1) VW 75206-2:2022-09 (p. 11.4.2, 11.4.3, 11.6)","search_zh":"电缆 容量 ISO 4141-1:2019 (p. 6.3) | EN 50289-1-5:2001 VW 75206-1:2020-11 (p. 6.3.1) VW 75206-2:2022-09 (p. 11.4.2, 11.4.3, 11.6)","test_object_zh":"电缆","parameters_zh":[{"name":"容量"},{"name":"Pojemność efektywna"},{"name":"Pojemność magistrali"},{"name":"Pojemność jednostkowa"},{"name":"Pojemność niesymetryczna"},{"name":"Częstotliwość: 1 kHz"}]},{"_id":"6a5dc9a9f1c10c8ce8259eb8","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Pomiar pojemności elektrycznej, indukcyjności jednostkowej","methodology_en":"Measurement of capacitance, unit inductance","parameters":[{"name":"Indukcyjność jednostkowa"},{"name":"Częstotliwość","range":"50 Hz - 1 kHz"}],"parameters_en":[{"name":"Unit inductance"},{"name":"Frequency","range":"50 Hz - 1 kHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pomiar pojemności elektrycznej, indukcyjności jednostkowej\nZakres:\nIndukcyjność jednostkowa\nCzęstotliwość 50 Hz - 1 kHz","reference":"EN 50289-1-12:2005 VW 75206-2:2022-09 (p. 11.7)","norm_bases":["EN 50289-1-12:2005 VW 75206-2:2022-09 (p. 11.7)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Pomiar pojemności elektrycznej, indukcyjności jednostkowej\nZakres:\nIndukcyjność jednostkowa\nCzęstotliwość 50 Hz - 1 kHz EN 50289-1-12:2005 VW 75206-2:2022-09 (p. 11.7) Kable, Cables Pomiar pojemnosci elektrycznej, indukcyjnosci jednostkowej\nZakres:\nIndukcyjnosc jednostkowa\nCzestotliwosc 50 Hz - 1 kHz EN 50289-1-12:2005 VW 75206-2:2022-09 (p. 11.7)","categories":["other"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Measurement of capacitance, unit inductance Unit inductance Frequency EN 50289-1-12:2005 VW 75206-2:2022-09 (p. 11.7)","parameters_zh":[{"name":"Indukcyjność jednostkowa"},{"name":"频率","range":"50 Hz - 1 kHz"}],"search_zh":"电缆 频率 EN 50289-1-12:2005 VW 75206-2:2022-09 (p. 11.7)","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259eb9","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Badania integralności sygnałów","methodology_en":"Signal integrity tests","parameters":[{"name":"Prędkość oraz czas propagacji"},{"name":"Częstotliwość","range":"100 kHz - 6000 MHz"}],"parameters_en":[{"name":"Propagation velocity and time"},{"name":"Frequency","range":"100 kHz - 6000 MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania integralności sygnałów\nZakres:\nPrędkość oraz czas propagacji\nCzęstotliwość 100 kHz - 6000 MHz","reference":"EN 50289-1-7:2001 VW 75206-1:2020-11 (p. 6.3.2) VW 75206-2:2022-09 (p. 12.2)","norm_bases":["EN 50289-1-7:2001 VW 75206-1:2020-11 (p. 6.3.2) VW 75206-2:2022-09 (p. 12.2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Badania integralności sygnałów\nZakres:\nPrędkość oraz czas propagacji\nCzęstotliwość 100 kHz - 6000 MHz EN 50289-1-7:2001 VW 75206-1:2020-11 (p. 6.3.2) VW 75206-2:2022-09 (p. 12.2) Kable, Cables Badania integralnosci sygnalow\nZakres:\nPredkosc oraz czas propagacji\nCzestotliwosc 100 kHz - 6000 MHz EN 50289-1-7:2001 VW 75206-1:2020-11 (p. 6.3.2) VW 75206-2:2022-09 (p. 12.2)","categories":["other"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Signal integrity tests Propagation velocity and time Frequency EN 50289-1-7:2001 VW 75206-1:2020-11 (p. 6.3.2) VW 75206-2:2022-09 (p. 12.2)","parameters_zh":[{"name":"Prędkość oraz czas propagacji"},{"name":"频率","range":"100 kHz - 6000 MHz"}],"search_zh":"电缆 信号完整性检验 频率 EN 50289-1-7:2001 VW 75206-1:2020-11 (p. 6.3.2) VW 75206-2:2022-09 (p. 12.2)","test_object_zh":"电缆","methodology_zh":"信号完整性检验"},{"_id":"6a5dc9a9f1c10c8ce8259eba","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Badania integralności sygnałów","methodology_en":"Signal integrity tests","parameters":[{"name":"Różnica w czasie propagacji pomiędzy parami"},{"name":"Częstotliwość","range":"100 kHz - 2500 MHz"}],"parameters_en":[{"name":"Difference in propagation time between pairs"},{"name":"Frequency","range":"100 kHz - 2500 MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania integralności sygnałów\nZakres:\nRóżnica w czasie propagacji pomiędzy parami\nCzęstotliwość 100 kHz - 2500 MHz","reference":"EN 50289-1-7:2001 VW 75206-2:2022-09 (p. 11.7) Scope of accreditation No. AB 1776","norm_bases":["EN 50289-1-7:2001 VW 75206-2:2022-09 (p. 11.7) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Badania integralności sygnałów\nZakres:\nRóżnica w czasie propagacji pomiędzy parami\nCzęstotliwość 100 kHz - 2500 MHz EN 50289-1-7:2001 VW 75206-2:2022-09 (p. 11.7) Scope of accreditation No. AB 1776 Kable, Cables Badania integralnosci sygnalow\nZakres:\nRoznica w czasie propagacji pomiedzy parami\nCzestotliwosc 100 kHz - 2500 MHz EN 50289-1-7:2001 VW 75206-2:2022-09 (p. 11.7) Scope of accreditation No. AB 1776","categories":["other"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Signal integrity tests Difference in propagation time between pairs Frequency EN 50289-1-7:2001 VW 75206-2:2022-09 (p. 11.7) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"Różnica w czasie propagacji pomiędzy parami"},{"name":"频率","range":"100 kHz - 2500 MHz"}],"search_zh":"电缆 信号完整性检验 频率 EN 50289-1-7:2001 VW 75206-2:2022-09 (p. 11.7) Scope of accreditation No. AB 1776","test_object_zh":"电缆","methodology_zh":"信号完整性检验"},{"_id":"6a5dc9a9f1c10c8ce8259ebb","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Badania integralności sygnałów","methodology_en":"Signal integrity tests","parameters":[{"name":"Różnica w czasie propagacji w obrębie jednej pary"},{"name":"Częstotliwość","range":"100 kHz - 5500 MHz"}],"parameters_en":[{"name":"Difference in propagation time within one pair"},{"name":"Frequency","range":"100 kHz - 5500 MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania integralności sygnałów\nZakres:\nRóżnica w czasie propagacji w obrębie jednej pary\nCzęstotliwość 100 kHz - 5500 MHz","reference":"EN 50289-1-7:2001 VW 75206-2:2022-09 (p. 11.7)","norm_bases":["EN 50289-1-7:2001 VW 75206-2:2022-09 (p. 11.7)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Badania integralności sygnałów\nZakres:\nRóżnica w czasie propagacji w obrębie jednej pary\nCzęstotliwość 100 kHz - 5500 MHz EN 50289-1-7:2001 VW 75206-2:2022-09 (p. 11.7) Kable, Cables Badania integralnosci sygnalow\nZakres:\nRoznica w czasie propagacji w obrebie jednej pary\nCzestotliwosc 100 kHz - 5500 MHz EN 50289-1-7:2001 VW 75206-2:2022-09 (p. 11.7)","categories":["other"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Signal integrity tests Difference in propagation time within one pair Frequency EN 50289-1-7:2001 VW 75206-2:2022-09 (p. 11.7)","parameters_zh":[{"name":"Różnica w czasie propagacji w obrębie jednej pary"},{"name":"频率","range":"100 kHz - 5500 MHz"}],"search_zh":"电缆 信号完整性检验 频率 EN 50289-1-7:2001 VW 75206-2:2022-09 (p. 11.7)","test_object_zh":"电缆","methodology_zh":"信号完整性检验"},{"_id":"6a5dc9a9f1c10c8ce8259ebc","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Badania integralności sygnałów","methodology_en":"Signal integrity tests","parameters":[{"name":"Wyznaczenie impedancji charakterystycznej na podstawie pojemności elektrycznej i prędkości propagacji"},{"name":"Częstotliwość","range":"100 kHz - 6000 MHz"}],"parameters_en":[{"name":"Determination of the characteristic impedance based on the electrical capacitance and propagation velocity"},{"name":"Frequency","range":"100 kHz - 6000 MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania integralności sygnałów\nZakres:\nWyznaczenie impedancji charakterystycznej na podstawie pojemności elektrycznej i prędkości propagacji\nCzęstotliwość 100 kHz - 6000 MHz","reference":"EN 50289-1-11:2016 (E) (z wyłączeniem p. 5.1) VW 75206-1:2020-11 (p. 6.3.3) VW 75206-2:2022-09 (p. 12.8.1)","norm_bases":["EN 50289-1-11:2016 (E) (z wyłączeniem p. 5.1) VW 75206-1:2020-11 (p. 6.3.3) VW 75206-2:2022-09 (p. 12.8.1)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Badania integralności sygnałów\nZakres:\nWyznaczenie impedancji charakterystycznej na podstawie pojemności elektrycznej i prędkości propagacji\nCzęstotliwość 100 kHz - 6000 MHz EN 50289-1-11:2016 (E) (z wyłączeniem p. 5.1) VW 75206-1:2020-11 (p. 6.3.3) VW 75206-2:2022-09 (p. 12.8.1) Kable, Cables Badania integralnosci sygnalow\nZakres:\nWyznaczenie impedancji charakterystycznej na podstawie pojemnosci elektrycznej i predkosci propagacji\nCzestotliwosc 100 kHz - 6000 MHz EN 50289-1-11:2016 (E) (z wylaczeniem p. 5.1) VW 75206-1:2020-11 (p. 6.3.3) VW 75206-2:2022-09 (p. 12.8.1)","categories":["other"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Signal integrity tests Determination of the characteristic impedance based on the electrical capacitance and propagation velocity Frequency EN 50289-1-11:2016 (E) (z wyłączeniem p. 5.1) VW 75206-1:2020-11 (p. 6.3.3) VW 75206-2:2022-09 (p. 12.8.1)","parameters_zh":[{"name":"Wyznaczenie impedancji charakterystycznej na podstawie pojemności elektrycznej i prędkości propagacji"},{"name":"频率","range":"100 kHz - 6000 MHz"}],"search_zh":"电缆 信号完整性检验 频率 EN 50289-1-11:2016 (E) (z wyłączeniem p. 5.1) VW 75206-1:2020-11 (p. 6.3.3) VW 75206-2:2022-09 (p. 12.8.1)","test_object_zh":"电缆","methodology_zh":"信号完整性检验"},{"_id":"6a5dc9a9f1c10c8ce8259ebd","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Badania integralności sygnałów","methodology_en":"Signal integrity tests","parameters":[{"name":"Straty odbiciowe"},{"name":"Częstotliwość","range":"100 kHz - 6000 MHz"}],"parameters_en":[{"name":"Return loss"},{"name":"Frequency","range":"100 kHz - 6000 MHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania integralności sygnałów\nZakres:\nStraty odbiciowe\nCzęstotliwość 100 kHz - 6000 MHz","reference":"EN 50289-1-11:2016 (E) (z wyłączeniem p. 5.1) VW 75206-1:2020-11 (p. 6.4) VW 75206-2:2022-09 (p. 12.9)","norm_bases":["EN 50289-1-11:2016 (E) (z wyłączeniem p. 5.1) VW 75206-1:2020-11 (p. 6.4) VW 75206-2:2022-09 (p. 12.9)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Badania integralności sygnałów\nZakres:\nStraty odbiciowe\nCzęstotliwość 100 kHz - 6000 MHz EN 50289-1-11:2016 (E) (z wyłączeniem p. 5.1) VW 75206-1:2020-11 (p. 6.4) VW 75206-2:2022-09 (p. 12.9) Kable, Cables Badania integralnosci sygnalow\nZakres:\nStraty odbiciowe\nCzestotliwosc 100 kHz - 6000 MHz EN 50289-1-11:2016 (E) (z wylaczeniem p. 5.1) VW 75206-1:2020-11 (p. 6.4) VW 75206-2:2022-09 (p. 12.9)","categories":["other"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Signal integrity tests Return loss Frequency EN 50289-1-11:2016 (E) (z wyłączeniem p. 5.1) VW 75206-1:2020-11 (p. 6.4) VW 75206-2:2022-09 (p. 12.9)","parameters_zh":[{"name":"Straty odbiciowe"},{"name":"频率","range":"100 kHz - 6000 MHz"}],"search_zh":"电缆 信号完整性检验 频率 EN 50289-1-11:2016 (E) (z wyłączeniem p. 5.1) VW 75206-1:2020-11 (p. 6.4) VW 75206-2:2022-09 (p. 12.9)","test_object_zh":"电缆","methodology_zh":"信号完整性检验"},{"_id":"6a5dc9a9f1c10c8ce8259ebe","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Badania integralności sygnałów","methodology_en":"Signal integrity tests","parameters":[{"name":"Tłumienność niesymetrii (konwersja trybu sygnału):"},{"name":"Straty konwersji wzdłużnej"},{"name":"Straty transferu konwersji wzdłużnej"},{"name":"Częstotliwość","range":"100 kHz - 3 GHz"}],"parameters_en":[{"name":"Unbalance attenuation (signal mode conversion):"},{"name":"Longitudinal conversion loss"},{"name":"Longitudinal conversion transfer loss"},{"name":"Frequency","range":"100 kHz - 3 GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania integralności sygnałów\nZakres:\nTłumienność niesymetrii (konwersja trybu sygnału):\nStraty konwersji wzdłużnej\nStraty transferu konwersji wzdłużnej\nCzęstotliwość 100 kHz - 3 GHz","reference":"EN 50289-1-9:2017 (E) (z wyłączeniem p. 4.1) VW 75206-2:2022-09 (p. 12.5) Scope of accreditation No. AB 1776","norm_bases":["EN 50289-1-9:2017 (E) (z wyłączeniem p. 4.1) VW 75206-2:2022-09 (p. 12.5) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Badania integralności sygnałów\nZakres:\nTłumienność niesymetrii (konwersja trybu sygnału):\nStraty konwersji wzdłużnej\nStraty transferu konwersji wzdłużnej\nCzęstotliwość 100 kHz - 3 GHz EN 50289-1-9:2017 (E) (z wyłączeniem p. 4.1) VW 75206-2:2022-09 (p. 12.5) Scope of accreditation No. AB 1776 Kable, Cables Badania integralnosci sygnalow\nZakres:\nTlumiennosc niesymetrii (konwersja trybu sygnalu):\nStraty konwersji wzdluznej\nStraty transferu konwersji wzdluznej\nCzestotliwosc 100 kHz - 3 GHz EN 50289-1-9:2017 (E) (z wylaczeniem p. 4.1) VW 75206-2:2022-09 (p. 12.5) Scope of accreditation No. AB 1776","categories":["other"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Signal integrity tests Unbalance attenuation (signal mode conversion): Longitudinal conversion loss Longitudinal conversion transfer loss Frequency EN 50289-1-9:2017 (E) (z wyłączeniem p. 4.1) VW 75206-2:2022-09 (p. 12.5) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"Tłumienność niesymetrii (konwersja trybu sygnału):"},{"name":"Straty konwersji wzdłużnej"},{"name":"Straty transferu konwersji wzdłużnej"},{"name":"频率","range":"100 kHz - 3 GHz"}],"search_zh":"电缆 信号完整性检验 频率 EN 50289-1-9:2017 (E) (z wyłączeniem p. 4.1) VW 75206-2:2022-09 (p. 12.5) Scope of accreditation No. AB 1776","test_object_zh":"电缆","methodology_zh":"信号完整性检验"},{"_id":"6a5dc9a9f1c10c8ce8259ebf","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Badania integralności sygnałów","methodology_en":"Signal integrity tests","parameters":[{"name":"Wyznaczenie impedancji charakterystycznej z użyciem reflektometru w domenie czasu"},{"name":"Częstotliwość","range":"1 MHz - 10 GHz"}],"parameters_en":[{"name":"Determination of the characteristic impedance using a time domain reflectometer"},{"name":"Frequency","range":"1 MHz - 10 GHz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania integralności sygnałów\nZakres:\nWyznaczenie impedancji charakterystycznej z użyciem reflektometru w domenie czasu\nCzęstotliwość 1 MHz - 10 GHz","reference":"VW 75206-1:2020-11 (p. 7.5.5) VW 75206-2:2022-09 (p. 10.4, 12.8.2)","norm_bases":["VW 75206-1:2020-11 (p. 7.5.5) VW 75206-2:2022-09 (p. 10.4, 12.8.2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Badania integralności sygnałów\nZakres:\nWyznaczenie impedancji charakterystycznej z użyciem reflektometru w domenie czasu\nCzęstotliwość 1 MHz - 10 GHz VW 75206-1:2020-11 (p. 7.5.5) VW 75206-2:2022-09 (p. 10.4, 12.8.2) Kable, Cables Badania integralnosci sygnalow\nZakres:\nWyznaczenie impedancji charakterystycznej z uzyciem reflektometru w domenie czasu\nCzestotliwosc 1 MHz - 10 GHz VW 75206-1:2020-11 (p. 7.5.5) VW 75206-2:2022-09 (p. 10.4, 12.8.2)","categories":["other"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Signal integrity tests Determination of the characteristic impedance using a time domain reflectometer Frequency VW 75206-1:2020-11 (p. 7.5.5) VW 75206-2:2022-09 (p. 10.4, 12.8.2)","parameters_zh":[{"name":"Wyznaczenie impedancji charakterystycznej z użyciem reflektometru w domenie czasu"},{"name":"频率","range":"1 MHz - 10 GHz"}],"search_zh":"电缆 信号完整性检验 频率 VW 75206-1:2020-11 (p. 7.5.5) VW 75206-2:2022-09 (p. 10.4, 12.8.2)","test_object_zh":"电缆","methodology_zh":"信号完整性检验"},{"_id":"6a5dc9a9f1c10c8ce8259ec0","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Badania kompatybilności elektromagnetycznej","methodology_en":"Electromagnetic compatibility testing","parameters":[{"name":"Tłumienność sprzężeniowa"},{"name":"Częstotliwość","range":"30 MHz - 5500 MHz"},{"name":"Electromagnetic Compatibility (EMC)"}],"parameters_en":[{"name":"Coupling attenuation"},{"name":"Frequency","range":"30 MHz - 5500 MHz"},{"name":"Electromagnetic Compatibility (EMC)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania kompatybilności elektromagnetycznej\nZakres:\nTłumienność sprzężeniowa\nCzęstotliwość 30 MHz - 5500 MHz\nElectromagnetic Compatibility (EMC)","reference":"IEC 62153-4-9 Ed. 2.0 b:2018 (z wyłączeniem procedury B (7.2)) VW 75206-2:2022-09 (p. 12.10)","norm_bases":["IEC 62153-4-9 Ed. 2.0 b:2018 (z wyłączeniem procedury B (7.2)) VW 75206-2:2022-09 (p. 12.10)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Badania kompatybilności elektromagnetycznej\nZakres:\nTłumienność sprzężeniowa\nCzęstotliwość 30 MHz - 5500 MHz\nElectromagnetic Compatibility (EMC) IEC 62153-4-9 Ed. 2.0 b:2018 (z wyłączeniem procedury B (7.2)) VW 75206-2:2022-09 (p. 12.10) Kable, Cables Badania kompatybilnosci elektromagnetycznej\nZakres:\nTlumiennosc sprzezeniowa\nCzestotliwosc 30 MHz - 5500 MHz\nElectromagnetic Compatibility (EMC) IEC 62153-4-9 Ed. 2.0 b:2018 (z wylaczeniem procedury B (7.2)) VW 75206-2:2022-09 (p. 12.10)","categories":["electronics"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Electromagnetic compatibility testing Coupling attenuation Frequency Electromagnetic Compatibility (EMC) IEC 62153-4-9 Ed. 2.0 b:2018 (z wyłączeniem procedury B (7.2)) VW 75206-2:2022-09 (p. 12.10)","parameters_zh":[{"name":"Tłumienność sprzężeniowa"},{"name":"频率","range":"30 MHz - 5500 MHz"},{"name":"电磁兼容（EMC）/ Electromagnetic Compatibility (EMC)"}],"search_zh":"电缆 电磁兼容检验 频率 电磁兼容（EMC）/ Electromagnetic Compatibility (EMC) IEC 62153-4-9 Ed. 2.0 b:2018 (z wyłączeniem procedury B (7.2)) VW 75206-2:2022-09 (p. 12.10)","test_object_zh":"电缆","methodology_zh":"电磁兼容检验"},{"_id":"6a5dc9a9f1c10c8ce8259ec1","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Badania kompatybilności elektromagnetycznej","methodology_en":"Electromagnetic compatibility testing","parameters":[{"name":"Impedancja przejściowa"},{"name":"Częstotliwość","range":"10 kHz - 62,5 MHz"},{"name":"Electromagnetic Compatibility (EMC)"}],"parameters_en":[{"name":"Transfer impedance"},{"name":"Frequency","range":"10 kHz - 62,5 MHz"},{"name":"Electromagnetic Compatibility (EMC)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania kompatybilności elektromagnetycznej\nZakres:\nImpedancja przejściowa\nCzęstotliwość 10 kHz - 62,5 MHz\nElectromagnetic Compatibility (EMC)","reference":"IEC 62153-4-3 Ed. 2.0 b:2013 (z wyłączeniem metody A (p. 6) oraz metody \"milked on braid\" (Annex C). VW 75206-1:2020-11 (p. 6.5) VW 75206-2:2022-09 (p. 6.6)","norm_bases":["IEC 62153-4-3 Ed. 2.0 b:2013 (z wyłączeniem metody A (p. 6) oraz metody \"milked on braid\" (Annex C). VW 75206-1:2020-11 (p. 6.5) VW 75206-2:2022-09 (p. 6.6)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Badania kompatybilności elektromagnetycznej\nZakres:\nImpedancja przejściowa\nCzęstotliwość 10 kHz - 62,5 MHz\nElectromagnetic Compatibility (EMC) IEC 62153-4-3 Ed. 2.0 b:2013 (z wyłączeniem metody A (p. 6) oraz metody \"milked on braid\" (Annex C). VW 75206-1:2020-11 (p. 6.5) VW 75206-2:2022-09 (p. 6.6) Kable, Cables Badania kompatybilnosci elektromagnetycznej\nZakres:\nImpedancja przejsciowa\nCzestotliwosc 10 kHz - 62,5 MHz\nElectromagnetic Compatibility (EMC) IEC 62153-4-3 Ed. 2.0 b:2013 (z wylaczeniem metody A (p. 6) oraz metody \"milked on braid\" (Annex C). VW 75206-1:2020-11 (p. 6.5) VW 75206-2:2022-09 (p. 6.6)","categories":["electronics","food"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Electromagnetic compatibility testing Transfer impedance Frequency Electromagnetic Compatibility (EMC) IEC 62153-4-3 Ed. 2.0 b:2013 (z wyłączeniem metody A (p. 6) oraz metody \"milked on braid\" (Annex C). VW 75206-1:2020-11 (p. 6.5) VW 75206-2:2022-09 (p. 6.6)","parameters_zh":[{"name":"Impedancja przejściowa"},{"name":"频率","range":"10 kHz - 62,5 MHz"},{"name":"电磁兼容（EMC）/ Electromagnetic Compatibility (EMC)"}],"search_zh":"电缆 电磁兼容检验 频率 电磁兼容（EMC）/ Electromagnetic Compatibility (EMC) IEC 62153-4-3 Ed. 2.0 b:2013 (z wyłączeniem metody A (p. 6) oraz metody \"milked on braid\" (Annex C). VW 75206-1:2020-11 (p. 6.5) VW 75206-2:2022-09 (p. 6.6)","test_object_zh":"电缆","methodology_zh":"电磁兼容检验"},{"_id":"6a5dc9a9f1c10c8ce8259ec2","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Badania kompatybilności elektromagnetycznej","methodology_en":"Electromagnetic compatibility testing","parameters":[{"name":"Tłumienność ekranowania"},{"name":"Częstotliwość","range":"30 MHz - 6000 MHz"},{"name":"Electromagnetic Compatibility (EMC)"}],"parameters_en":[{"name":"Screening attenuation"},{"name":"Frequency","range":"30 MHz - 6000 MHz"},{"name":"Electromagnetic Compatibility (EMC)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania kompatybilności elektromagnetycznej\nZakres:\nTłumienność ekranowania\nCzęstotliwość 30 MHz - 6000 MHz\nElectromagnetic Compatibility (EMC)","reference":"IEC 62153-4-4 Ed. 2.0 b:2015 | EN 50289-1-6:2002 (p. 8) VW 75206-1:2020-11 (p. 6.6) VW 75206-2:2022-09 (p. 12.12) Scope of accreditation No. AB 1776","norm_bases":["IEC 62153-4-4 Ed. 2.0 b:2015","EN 50289-1-6:2002 (p. 8) VW 75206-1:2020-11 (p. 6.6) VW 75206-2:2022-09 (p. 12.12) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Badania kompatybilności elektromagnetycznej\nZakres:\nTłumienność ekranowania\nCzęstotliwość 30 MHz - 6000 MHz\nElectromagnetic Compatibility (EMC) IEC 62153-4-4 Ed. 2.0 b:2015 | EN 50289-1-6:2002 (p. 8) VW 75206-1:2020-11 (p. 6.6) VW 75206-2:2022-09 (p. 12.12) Scope of accreditation No. AB 1776 Kable, Cables Badania kompatybilnosci elektromagnetycznej\nZakres:\nTlumiennosc ekranowania\nCzestotliwosc 30 MHz - 6000 MHz\nElectromagnetic Compatibility (EMC) IEC 62153-4-4 Ed. 2.0 b:2015 | EN 50289-1-6:2002 (p. 8) VW 75206-1:2020-11 (p. 6.6) VW 75206-2:2022-09 (p. 12.12) Scope of accreditation No. AB 1776","categories":["electronics"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Electromagnetic compatibility testing Screening attenuation Frequency Electromagnetic Compatibility (EMC) IEC 62153-4-4 Ed. 2.0 b:2015 | EN 50289-1-6:2002 (p. 8) VW 75206-1:2020-11 (p. 6.6) VW 75206-2:2022-09 (p. 12.12) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"Tłumienność ekranowania"},{"name":"频率","range":"30 MHz - 6000 MHz"},{"name":"电磁兼容（EMC）/ Electromagnetic Compatibility (EMC)"}],"search_zh":"电缆 电磁兼容检验 频率 电磁兼容（EMC）/ Electromagnetic Compatibility (EMC) IEC 62153-4-4 Ed. 2.0 b:2015 | EN 50289-1-6:2002 (p. 8) VW 75206-1:2020-11 (p. 6.6) VW 75206-2:2022-09 (p. 12.12) Scope of accreditation No. AB 1776","test_object_zh":"电缆","methodology_zh":"电磁兼容检验"},{"_id":"6a5dc9a9f1c10c8ce8259ec3","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Średnica zewnętrzna kabla / powłoki","methodology_en":"External diameter of the cable / sheath","parameters":[{"name":"Zakres","range":"0,01 mm do 40 mm"},{"name":"Cable outside diameter Range:"}],"parameters_en":[{"name":"Range","range":"0,01 mm do 40 mm"},{"name":"Cable outside diameter Range:"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Średnica zewnętrzna kabla / powłoki\nZakres:\nZakres 0,01 mm do 40 mm\nCable outside diameter Range:","reference":"ISO 19642-2:2019-01 (p. 5.1.2; 6.1.1) | ISO 19642-2:2023 (p. 5.2.1, 6.2.1) | ISO 19642-3:2019-01 (p. 5.2.1) | ISO 19642-4:2019-01 (p. 5.2.1) | ISO 19642-5:2019-01 (p. 5.2.1) | ISO 19642-6:2019-01 (p. 5.2.1) | ISO 19642-7:2019-01 (p. 6.2.1) | ISO 19642-8:2019-01 (p. 6.2.1) | ISO 19642-9:2019-01 (p. 6.2.1) | ISO 19642-10:2019-01 (p. 6.2.1) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.1) | ISO 6722-2:2013-12-01 (p. 5.1) | ISO 14572:2011-10 (p. 5.1) LV 112-1:2013-04 (p. 9.1.1) LV 112-1:2014-04 (p. 9.1.1) LV 112-2:2007-11 (p. 8.1) LV 112-2:2013-04 (p. 9.1.1) VW 60306-1:2018-09-01 (p. 9.1.1) VW 60306-1:2021-10 (p. 9.2.2) VW 60306-2:2013-04 (p. 9.1.1) VW 60306-2:2021-11 (p. 9.2.2) VW 60306-4:2021-12 (p. 9.2.2) MBN LV 112-1:2016-03 (p. 9.1.1) MBN 50112-1:2023-06 (p. 12.1.2) MBN LV 112-2:2012-01 (p. 8.1) MBN 50112-2: 2023-05 (p. 12.1) MBN 50112-4: 2024-06 (p. 12.1.2) GS 95007-1-1:2013-05 (p. 9.1.1) GS 95007-1-2:2013-05 (p. 9.1.1) Scope of accreditation No. AB 1776","norm_bases":["ISO 19642-2:2019-01 (p. 5.1.2; 6.1.1)","ISO 19642-2:2023 (p. 5.2.1, 6.2.1)","ISO 19642-3:2019-01 (p. 5.2.1)","ISO 19642-4:2019-01 (p. 5.2.1)","ISO 19642-5:2019-01 (p. 5.2.1)","ISO 19642-6:2019-01 (p. 5.2.1)","ISO 19642-7:2019-01 (p. 6.2.1)","ISO 19642-8:2019-01 (p. 6.2.1)","ISO 19642-9:2019-01 (p. 6.2.1)","ISO 19642-10:2019-01 (p. 6.2.1)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.1)","ISO 6722-2:2013-12-01 (p. 5.1)","ISO 14572:2011-10 (p. 5.1) LV 112-1:2013-04 (p. 9.1.1) LV 112-1:2014-04 (p. 9.1.1) LV 112-2:2007-11 (p. 8.1) LV 112-2:2013-04 (p. 9.1.1) VW 60306-1:2018-09-01 (p. 9.1.1) VW 60306-1:2021-10 (p. 9.2.2) VW 60306-2:2013-04 (p. 9.1.1) VW 60306-2:2021-11 (p. 9.2.2) VW 60306-4:2021-12 (p. 9.2.2) MBN LV 112-1:2016-03 (p. 9.1.1) MBN 50112-1:2023-06 (p. 12.1.2) MBN LV 112-2:2012-01 (p. 8.1) MBN 50112-2: 2023-05 (p. 12.1) MBN 50112-4: 2024-06 (p. 12.1.2) GS 95007-1-1:2013-05 (p. 9.1.1) GS 95007-1-2:2013-05 (p. 9.1.1) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Średnica zewnętrzna kabla / powłoki\nZakres:\nZakres 0,01 mm do 40 mm\nCable outside diameter Range: ISO 19642-2:2019-01 (p. 5.1.2; 6.1.1) | ISO 19642-2:2023 (p. 5.2.1, 6.2.1) | ISO 19642-3:2019-01 (p. 5.2.1) | ISO 19642-4:2019-01 (p. 5.2.1) | ISO 19642-5:2019-01 (p. 5.2.1) | ISO 19642-6:2019-01 (p. 5.2.1) | ISO 19642-7:2019-01 (p. 6.2.1) | ISO 19642-8:2019-01 (p. 6.2.1) | ISO 19642-9:2019-01 (p. 6.2.1) | ISO 19642-10:2019-01 (p. 6.2.1) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.1) | ISO 6722-2:2013-12-01 (p. 5.1) | ISO 14572:2011-10 (p. 5.1) LV 112-1:2013-04 (p. 9.1.1) LV 112-1:2014-04 (p. 9.1.1) LV 112-2:2007-11 (p. 8.1) LV 112-2:2013-04 (p. 9.1.1) VW 60306-1:2018-09-01 (p. 9.1.1) VW 60306-1:2021-10 (p. 9.2.2) VW 60306-2:2013-04 (p. 9.1.1) VW 60306-2:2021-11 (p. 9.2.2) VW 60306-4:2021-12 (p. 9.2.2) MBN LV 112-1:2016-03 (p. 9.1.1) MBN 50112-1:2023-06 (p. 12.1.2) MBN LV 112-2:2012-01 (p. 8.1) MBN 50112-2: 2023-05 (p. 12.1) MBN 50112-4: 2024-06 (p. 12.1.2) GS 95007-1-1:2013-05 (p. 9.1.1) GS 95007-1-2:2013-05 (p. 9.1.1) Scope of accreditation No. AB 1776 Kable, Cables Srednica zewnetrzna kabla / powloki\nZakres:\nZakres 0,01 mm do 40 mm\nCable outside diameter Range: ISO 19642-2:2019-01 (p. 5.1.2; 6.1.1) | ISO 19642-2:2023 (p. 5.2.1, 6.2.1) | ISO 19642-3:2019-01 (p. 5.2.1) | ISO 19642-4:2019-01 (p. 5.2.1) | ISO 19642-5:2019-01 (p. 5.2.1) | ISO 19642-6:2019-01 (p. 5.2.1) | ISO 19642-7:2019-01 (p. 6.2.1) | ISO 19642-8:2019-01 (p. 6.2.1) | ISO 19642-9:2019-01 (p. 6.2.1) | ISO 19642-10:2019-01 (p. 6.2.1) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.1) | ISO 6722-2:2013-12-01 (p. 5.1) | ISO 14572:2011-10 (p. 5.1) LV 112-1:2013-04 (p. 9.1.1) LV 112-1:2014-04 (p. 9.1.1) LV 112-2:2007-11 (p. 8.1) LV 112-2:2013-04 (p. 9.1.1) VW 60306-1:2018-09-01 (p. 9.1.1) VW 60306-1:2021-10 (p. 9.2.2) VW 60306-2:2013-04 (p. 9.1.1) VW 60306-2:2021-11 (p. 9.2.2) VW 60306-4:2021-12 (p. 9.2.2) MBN LV 112-1:2016-03 (p. 9.1.1) MBN 50112-1:2023-06 (p. 12.1.2) MBN LV 112-2:2012-01 (p. 8.1) MBN 50112-2: 2023-05 (p. 12.1) MBN 50112-4: 2024-06 (p. 12.1.2) GS 95007-1-1:2013-05 (p. 9.1.1) GS 95007-1-2:2013-05 (p. 9.1.1) Scope of accreditation No. AB 1776","categories":["other"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables External diameter of the cable / sheath Range Cable outside diameter Range: ISO 19642-2:2019-01 (p. 5.1.2; 6.1.1) | ISO 19642-2:2023 (p. 5.2.1, 6.2.1) | ISO 19642-3:2019-01 (p. 5.2.1) | ISO 19642-4:2019-01 (p. 5.2.1) | ISO 19642-5:2019-01 (p. 5.2.1) | ISO 19642-6:2019-01 (p. 5.2.1) | ISO 19642-7:2019-01 (p. 6.2.1) | ISO 19642-8:2019-01 (p. 6.2.1) | ISO 19642-9:2019-01 (p. 6.2.1) | ISO 19642-10:2019-01 (p. 6.2.1) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.1) | ISO 6722-2:2013-12-01 (p. 5.1) | ISO 14572:2011-10 (p. 5.1) LV 112-1:2013-04 (p. 9.1.1) LV 112-1:2014-04 (p. 9.1.1) LV 112-2:2007-11 (p. 8.1) LV 112-2:2013-04 (p. 9.1.1) VW 60306-1:2018-09-01 (p. 9.1.1) VW 60306-1:2021-10 (p. 9.2.2) VW 60306-2:2013-04 (p. 9.1.1) VW 60306-2:2021-11 (p. 9.2.2) VW 60306-4:2021-12 (p. 9.2.2) MBN LV 112-1:2016-03 (p. 9.1.1) MBN 50112-1:2023-06 (p. 12.1.2) MBN LV 112-2:2012-01 (p. 8.1) MBN 50112-2: 2023-05 (p. 12.1) MBN 50112-4: 2024-06 (p. 12.1.2) GS 95007-1-1:2013-05 (p. 9.1.1) GS 95007-1-2:2013-05 (p. 9.1.1) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"范围","range":"0,01 mm do 40 mm"},{"name":"Cable outside diameter Range:"}],"search_zh":"电缆 范围 ISO 19642-2:2019-01 (p. 5.1.2; 6.1.1) | ISO 19642-2:2023 (p. 5.2.1, 6.2.1) | ISO 19642-3:2019-01 (p. 5.2.1) | ISO 19642-4:2019-01 (p. 5.2.1) | ISO 19642-5:2019-01 (p. 5.2.1) | ISO 19642-6:2019-01 (p. 5.2.1) | ISO 19642-7:2019-01 (p. 6.2.1) | ISO 19642-8:2019-01 (p. 6.2.1) | ISO 19642-9:2019-01 (p. 6.2.1) | ISO 19642-10:2019-01 (p. 6.2.1) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.1) | ISO 6722-2:2013-12-01 (p. 5.1) | ISO 14572:2011-10 (p. 5.1) LV 112-1:2013-04 (p. 9.1.1) LV 112-1:2014-04 (p. 9.1.1) LV 112-2:2007-11 (p. 8.1) LV 112-2:2013-04 (p. 9.1.1) VW 60306-1:2018-09-01 (p. 9.1.1) VW 60306-1:2021-10 (p. 9.2.2) VW 60306-2:2013-04 (p. 9.1.1) VW 60306-2:2021-11 (p. 9.2.2) VW 60306-4:2021-12 (p. 9.2.2) MBN LV 112-1:2016-03 (p. 9.1.1) MBN 50112-1:2023-06 (p. 12.1.2) MBN LV 112-2:2012-01 (p. 8.1) MBN 50112-2: 2023-05 (p. 12.1) MBN 50112-4: 2024-06 (p. 12.1.2) GS 95007-1-1:2013-05 (p. 9.1.1) GS 95007-1-2:2013-05 (p. 9.1.1) Scope of accreditation No. AB 1776","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ec4","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Grubość izolacji / powłoki","methodology_en":"Thickness of insulation / coating","parameters":[{"name":"Zakres","range":"(0,01 - 40) mm"},{"name":"Insulation thickness Range:","range":"(0,01 - 40) mm"}],"parameters_en":[{"name":"Range","range":"(0,01 - 40) mm"},{"name":"Insulation thickness Range:","range":"(0,01 - 40) mm"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Grubość izolacji / powłoki\nZakres:\nZakres (0,01 - 40) mm\nInsulation thickness Range: (0,01 - 40) mm","reference":"IEC 60811-201:2012 | IEC 60811-201:2012-03/AMD1:2017-07 | IEC 60811-201:2012-03/AMD2:2023-11 | IEC 60811-202:2012 | IEC 60811-202:2012-03/AMD1:2017-07 | IEC 60811-202:2012-03/AMD2:2023-11 | ISO 19642-2:2019-01 (p. 5.1.3, 6.1.3) | ISO 19642-2:2023 (p. 5.2.2; 6.2.3) | ISO 19642-3:2019-01 (p. 5.2.2) | ISO 19642-4:2019-01 (p. 5.2.2) | ISO 19642-5:2019-01 (p. 5.2.2) | ISO 19642-6:2019-01 (p. 5.2.2) | ISO 19642-7:2019-01 (p. 6.2.3) | ISO 19642-8:2019-01 (p. 6.2.3) | ISO 19642-9:2019-01 (p. 6.2.3) | ISO 19642-10:2019-01 (p. 6.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.2) | ISO 6722-2:2013-12-01 (p. 5.2) | ISO 14572:2011-10 (p. 5.3) LV 112-1:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) LV 112-1:2014-04 (p. 9.1.1; 9.1.4; 9.1.5) LV 112-2:2007-11 (p. 8.1, 8.2.3) LV 112-2:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) VW 60306-1:2018-09-01 (p. 9.1.1) VW 60306-1:2021-10 (p. 9.2.2) VW 60306-2:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) VW 60306-2:2021-11 (p. 9.2.2; 9.2.5) VW 60306-4:2021-12 (p. 9.2.2) MBN LV 112-1:2016-03 (p. 9.1.1, 9.1.4, 9.1.5) MBN 50112-1:2023-06 (p. 12.1.2; 12.1.5; 12.1.6) MBN LV 112-2:2012-01 (p. 8.1, 8.2.3) MBN 50112-2: 2023-05 (p. 12.1; 12.2.3) MBN 50112-4: 2024-06 (p. 12.1.2; 12.1.5; 12.1.6) GS 95007-1-1:2013-05 (p. 9.1.1, 9.1.4, 9.1.5) GS 95007-1-2:2013-05 (p. 9.1.1, 9.1.4, 9.1.5) Scope of accreditation No. AB 1776","norm_bases":["IEC 60811-201:2012","IEC 60811-201:2012-03/AMD1:2017-07","IEC 60811-201:2012-03/AMD2:2023-11","IEC 60811-202:2012","IEC 60811-202:2012-03/AMD1:2017-07","IEC 60811-202:2012-03/AMD2:2023-11","ISO 19642-2:2019-01 (p. 5.1.3, 6.1.3)","ISO 19642-2:2023 (p. 5.2.2; 6.2.3)","ISO 19642-3:2019-01 (p. 5.2.2)","ISO 19642-4:2019-01 (p. 5.2.2)","ISO 19642-5:2019-01 (p. 5.2.2)","ISO 19642-6:2019-01 (p. 5.2.2)","ISO 19642-7:2019-01 (p. 6.2.3)","ISO 19642-8:2019-01 (p. 6.2.3)","ISO 19642-9:2019-01 (p. 6.2.3)","ISO 19642-10:2019-01 (p. 6.2.3)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.2)","ISO 6722-2:2013-12-01 (p. 5.2)","ISO 14572:2011-10 (p. 5.3) LV 112-1:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) LV 112-1:2014-04 (p. 9.1.1; 9.1.4; 9.1.5) LV 112-2:2007-11 (p. 8.1, 8.2.3) LV 112-2:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) VW 60306-1:2018-09-01 (p. 9.1.1) VW 60306-1:2021-10 (p. 9.2.2) VW 60306-2:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) VW 60306-2:2021-11 (p. 9.2.2; 9.2.5) VW 60306-4:2021-12 (p. 9.2.2) MBN LV 112-1:2016-03 (p. 9.1.1, 9.1.4, 9.1.5) MBN 50112-1:2023-06 (p. 12.1.2; 12.1.5; 12.1.6) MBN LV 112-2:2012-01 (p. 8.1, 8.2.3) MBN 50112-2: 2023-05 (p. 12.1; 12.2.3) MBN 50112-4: 2024-06 (p. 12.1.2; 12.1.5; 12.1.6) GS 95007-1-1:2013-05 (p. 9.1.1, 9.1.4, 9.1.5) GS 95007-1-2:2013-05 (p. 9.1.1, 9.1.4, 9.1.5) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Grubość izolacji / powłoki\nZakres:\nZakres (0,01 - 40) mm\nInsulation thickness Range: (0,01 - 40) mm IEC 60811-201:2012 | IEC 60811-201:2012-03/AMD1:2017-07 | IEC 60811-201:2012-03/AMD2:2023-11 | IEC 60811-202:2012 | IEC 60811-202:2012-03/AMD1:2017-07 | IEC 60811-202:2012-03/AMD2:2023-11 | ISO 19642-2:2019-01 (p. 5.1.3, 6.1.3) | ISO 19642-2:2023 (p. 5.2.2; 6.2.3) | ISO 19642-3:2019-01 (p. 5.2.2) | ISO 19642-4:2019-01 (p. 5.2.2) | ISO 19642-5:2019-01 (p. 5.2.2) | ISO 19642-6:2019-01 (p. 5.2.2) | ISO 19642-7:2019-01 (p. 6.2.3) | ISO 19642-8:2019-01 (p. 6.2.3) | ISO 19642-9:2019-01 (p. 6.2.3) | ISO 19642-10:2019-01 (p. 6.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.2) | ISO 6722-2:2013-12-01 (p. 5.2) | ISO 14572:2011-10 (p. 5.3) LV 112-1:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) LV 112-1:2014-04 (p. 9.1.1; 9.1.4; 9.1.5) LV 112-2:2007-11 (p. 8.1, 8.2.3) LV 112-2:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) VW 60306-1:2018-09-01 (p. 9.1.1) VW 60306-1:2021-10 (p. 9.2.2) VW 60306-2:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) VW 60306-2:2021-11 (p. 9.2.2; 9.2.5) VW 60306-4:2021-12 (p. 9.2.2) MBN LV 112-1:2016-03 (p. 9.1.1, 9.1.4, 9.1.5) MBN 50112-1:2023-06 (p. 12.1.2; 12.1.5; 12.1.6) MBN LV 112-2:2012-01 (p. 8.1, 8.2.3) MBN 50112-2: 2023-05 (p. 12.1; 12.2.3) MBN 50112-4: 2024-06 (p. 12.1.2; 12.1.5; 12.1.6) GS 95007-1-1:2013-05 (p. 9.1.1, 9.1.4, 9.1.5) GS 95007-1-2:2013-05 (p. 9.1.1, 9.1.4, 9.1.5) Scope of accreditation No. AB 1776 Kable, Cables Grubosc izolacji / powloki\nZakres:\nZakres (0,01 - 40) mm\nInsulation thickness Range: (0,01 - 40) mm IEC 60811-201:2012 | IEC 60811-201:2012-03/AMD1:2017-07 | IEC 60811-201:2012-03/AMD2:2023-11 | IEC 60811-202:2012 | IEC 60811-202:2012-03/AMD1:2017-07 | IEC 60811-202:2012-03/AMD2:2023-11 | ISO 19642-2:2019-01 (p. 5.1.3, 6.1.3) | ISO 19642-2:2023 (p. 5.2.2; 6.2.3) | ISO 19642-3:2019-01 (p. 5.2.2) | ISO 19642-4:2019-01 (p. 5.2.2) | ISO 19642-5:2019-01 (p. 5.2.2) | ISO 19642-6:2019-01 (p. 5.2.2) | ISO 19642-7:2019-01 (p. 6.2.3) | ISO 19642-8:2019-01 (p. 6.2.3) | ISO 19642-9:2019-01 (p. 6.2.3) | ISO 19642-10:2019-01 (p. 6.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.2) | ISO 6722-2:2013-12-01 (p. 5.2) | ISO 14572:2011-10 (p. 5.3) LV 112-1:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) LV 112-1:2014-04 (p. 9.1.1; 9.1.4; 9.1.5) LV 112-2:2007-11 (p. 8.1, 8.2.3) LV 112-2:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) VW 60306-1:2018-09-01 (p. 9.1.1) VW 60306-1:2021-10 (p. 9.2.2) VW 60306-2:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) VW 60306-2:2021-11 (p. 9.2.2; 9.2.5) VW 60306-4:2021-12 (p. 9.2.2) MBN LV 112-1:2016-03 (p. 9.1.1, 9.1.4, 9.1.5) MBN 50112-1:2023-06 (p. 12.1.2; 12.1.5; 12.1.6) MBN LV 112-2:2012-01 (p. 8.1, 8.2.3) MBN 50112-2: 2023-05 (p. 12.1; 12.2.3) MBN 50112-4: 2024-06 (p. 12.1.2; 12.1.5; 12.1.6) GS 95007-1-1:2013-05 (p. 9.1.1, 9.1.4, 9.1.5) GS 95007-1-2:2013-05 (p. 9.1.1, 9.1.4, 9.1.5) Scope of accreditation No. AB 1776","categories":["construction"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Thickness of insulation / coating Range Insulation thickness Range: IEC 60811-201:2012 | IEC 60811-201:2012-03/AMD1:2017-07 | IEC 60811-201:2012-03/AMD2:2023-11 | IEC 60811-202:2012 | IEC 60811-202:2012-03/AMD1:2017-07 | IEC 60811-202:2012-03/AMD2:2023-11 | ISO 19642-2:2019-01 (p. 5.1.3, 6.1.3) | ISO 19642-2:2023 (p. 5.2.2; 6.2.3) | ISO 19642-3:2019-01 (p. 5.2.2) | ISO 19642-4:2019-01 (p. 5.2.2) | ISO 19642-5:2019-01 (p. 5.2.2) | ISO 19642-6:2019-01 (p. 5.2.2) | ISO 19642-7:2019-01 (p. 6.2.3) | ISO 19642-8:2019-01 (p. 6.2.3) | ISO 19642-9:2019-01 (p. 6.2.3) | ISO 19642-10:2019-01 (p. 6.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.2) | ISO 6722-2:2013-12-01 (p. 5.2) | ISO 14572:2011-10 (p. 5.3) LV 112-1:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) LV 112-1:2014-04 (p. 9.1.1; 9.1.4; 9.1.5) LV 112-2:2007-11 (p. 8.1, 8.2.3) LV 112-2:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) VW 60306-1:2018-09-01 (p. 9.1.1) VW 60306-1:2021-10 (p. 9.2.2) VW 60306-2:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) VW 60306-2:2021-11 (p. 9.2.2; 9.2.5) VW 60306-4:2021-12 (p. 9.2.2) MBN LV 112-1:2016-03 (p. 9.1.1, 9.1.4, 9.1.5) MBN 50112-1:2023-06 (p. 12.1.2; 12.1.5; 12.1.6) MBN LV 112-2:2012-01 (p. 8.1, 8.2.3) MBN 50112-2: 2023-05 (p. 12.1; 12.2.3) MBN 50112-4: 2024-06 (p. 12.1.2; 12.1.5; 12.1.6) GS 95007-1-1:2013-05 (p. 9.1.1, 9.1.4, 9.1.5) GS 95007-1-2:2013-05 (p. 9.1.1, 9.1.4, 9.1.5) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"范围","range":"(0,01 - 40) mm"},{"name":"Insulation thickness Range:","range":"(0,01 - 40) mm"}],"search_zh":"电缆 范围 IEC 60811-201:2012 | IEC 60811-201:2012-03/AMD1:2017-07 | IEC 60811-201:2012-03/AMD2:2023-11 | IEC 60811-202:2012 | IEC 60811-202:2012-03/AMD1:2017-07 | IEC 60811-202:2012-03/AMD2:2023-11 | ISO 19642-2:2019-01 (p. 5.1.3, 6.1.3) | ISO 19642-2:2023 (p. 5.2.2; 6.2.3) | ISO 19642-3:2019-01 (p. 5.2.2) | ISO 19642-4:2019-01 (p. 5.2.2) | ISO 19642-5:2019-01 (p. 5.2.2) | ISO 19642-6:2019-01 (p. 5.2.2) | ISO 19642-7:2019-01 (p. 6.2.3) | ISO 19642-8:2019-01 (p. 6.2.3) | ISO 19642-9:2019-01 (p. 6.2.3) | ISO 19642-10:2019-01 (p. 6.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.2) | ISO 6722-2:2013-12-01 (p. 5.2) | ISO 14572:2011-10 (p. 5.3) LV 112-1:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) LV 112-1:2014-04 (p. 9.1.1; 9.1.4; 9.1.5) LV 112-2:2007-11 (p. 8.1, 8.2.3) LV 112-2:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) VW 60306-1:2018-09-01 (p. 9.1.1) VW 60306-1:2021-10 (p. 9.2.2) VW 60306-2:2013-04 (p. 9.1.1, 9.1.4, 9.1.5) VW 60306-2:2021-11 (p. 9.2.2; 9.2.5) VW 60306-4:2021-12 (p. 9.2.2) MBN LV 112-1:2016-03 (p. 9.1.1, 9.1.4, 9.1.5) MBN 50112-1:2023-06 (p. 12.1.2; 12.1.5; 12.1.6) MBN LV 112-2:2012-01 (p. 8.1, 8.2.3) MBN 50112-2: 2023-05 (p. 12.1; 12.2.3) MBN 50112-4: 2024-06 (p. 12.1.2; 12.1.5; 12.1.6) GS 95007-1-1:2013-05 (p. 9.1.1, 9.1.4, 9.1.5) GS 95007-1-2:2013-05 (p. 9.1.1, 9.1.4, 9.1.5) Scope of accreditation No. AB 1776","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ec5","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Średnica przewodnika","methodology_en":"Conductor diameter","parameters":[{"name":"Zakres","range":"(0,01 - 40) mm"},{"name":"Conductor diameter Range:","range":"(0,01 - 40) mm"}],"parameters_en":[{"name":"Range","range":"(0,01 - 40) mm"},{"name":"Conductor diameter Range:","range":"(0,01 - 40) mm"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Średnica przewodnika\nZakres:\nZakres (0,01 - 40) mm\nConductor diameter Range: (0,01 - 40) mm","reference":"ISO 19642-2:2019-01 (p. 5.1.4) | ISO 19642-2:2023 (p. 5.2.3) | ISO 19642-3:2019-01 (p. 5.2.3) | ISO 19642-4:2019-01 (p. 5.2.3) | ISO 19642-5:2019-01 (p. 5.2.3) | ISO 19642-6:2019-01 (p. 5.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.3) | ISO 6722-2:2013-12-01 (p. 5.3.1) LV 112-1:2013-04 (p. 9.1.2) LV 112-1:2014-04 (p. 9.1.2) LV 112-2:2007-11 (p. 8.1) VW 60306-1:2018-09-01 (p. 9.1.2) VW 60306-1:2021-10 (p. 9.2.3) VW 60306-2:2013-04 (p. 9.1.2) VW 60306-2:2021-11 (p. 9.2.3) VW 60306-4:2021-12 (p. 9.2.3) MBN LV 112-1:2016-03 (p. 9.1.2) MBN 50112-1:2023-06 (p. 12.1.3) MBN LV 112-2:2012-01 (p. 8.1) MBN 50112-2: 2023-05 (p. 12.1) MBN 50112-4: 2024-06 (p. 12.1.3; 12.1.3.1) GS 95007-1-1:2013-05 (p. 9.1.2)","norm_bases":["ISO 19642-2:2019-01 (p. 5.1.4)","ISO 19642-2:2023 (p. 5.2.3)","ISO 19642-3:2019-01 (p. 5.2.3)","ISO 19642-4:2019-01 (p. 5.2.3)","ISO 19642-5:2019-01 (p. 5.2.3)","ISO 19642-6:2019-01 (p. 5.2.3)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.3)","ISO 6722-2:2013-12-01 (p. 5.3.1) LV 112-1:2013-04 (p. 9.1.2) LV 112-1:2014-04 (p. 9.1.2) LV 112-2:2007-11 (p. 8.1) VW 60306-1:2018-09-01 (p. 9.1.2) VW 60306-1:2021-10 (p. 9.2.3) VW 60306-2:2013-04 (p. 9.1.2) VW 60306-2:2021-11 (p. 9.2.3) VW 60306-4:2021-12 (p. 9.2.3) MBN LV 112-1:2016-03 (p. 9.1.2) MBN 50112-1:2023-06 (p. 12.1.3) MBN LV 112-2:2012-01 (p. 8.1) MBN 50112-2: 2023-05 (p. 12.1) MBN 50112-4: 2024-06 (p. 12.1.3; 12.1.3.1) GS 95007-1-1:2013-05 (p. 9.1.2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Średnica przewodnika\nZakres:\nZakres (0,01 - 40) mm\nConductor diameter Range: (0,01 - 40) mm ISO 19642-2:2019-01 (p. 5.1.4) | ISO 19642-2:2023 (p. 5.2.3) | ISO 19642-3:2019-01 (p. 5.2.3) | ISO 19642-4:2019-01 (p. 5.2.3) | ISO 19642-5:2019-01 (p. 5.2.3) | ISO 19642-6:2019-01 (p. 5.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.3) | ISO 6722-2:2013-12-01 (p. 5.3.1) LV 112-1:2013-04 (p. 9.1.2) LV 112-1:2014-04 (p. 9.1.2) LV 112-2:2007-11 (p. 8.1) VW 60306-1:2018-09-01 (p. 9.1.2) VW 60306-1:2021-10 (p. 9.2.3) VW 60306-2:2013-04 (p. 9.1.2) VW 60306-2:2021-11 (p. 9.2.3) VW 60306-4:2021-12 (p. 9.2.3) MBN LV 112-1:2016-03 (p. 9.1.2) MBN 50112-1:2023-06 (p. 12.1.3) MBN LV 112-2:2012-01 (p. 8.1) MBN 50112-2: 2023-05 (p. 12.1) MBN 50112-4: 2024-06 (p. 12.1.3; 12.1.3.1) GS 95007-1-1:2013-05 (p. 9.1.2) Kable, Cables Srednica przewodnika\nZakres:\nZakres (0,01 - 40) mm\nConductor diameter Range: (0,01 - 40) mm ISO 19642-2:2019-01 (p. 5.1.4) | ISO 19642-2:2023 (p. 5.2.3) | ISO 19642-3:2019-01 (p. 5.2.3) | ISO 19642-4:2019-01 (p. 5.2.3) | ISO 19642-5:2019-01 (p. 5.2.3) | ISO 19642-6:2019-01 (p. 5.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.3) | ISO 6722-2:2013-12-01 (p. 5.3.1) LV 112-1:2013-04 (p. 9.1.2) LV 112-1:2014-04 (p. 9.1.2) LV 112-2:2007-11 (p. 8.1) VW 60306-1:2018-09-01 (p. 9.1.2) VW 60306-1:2021-10 (p. 9.2.3) VW 60306-2:2013-04 (p. 9.1.2) VW 60306-2:2021-11 (p. 9.2.3) VW 60306-4:2021-12 (p. 9.2.3) MBN LV 112-1:2016-03 (p. 9.1.2) MBN 50112-1:2023-06 (p. 12.1.3) MBN LV 112-2:2012-01 (p. 8.1) MBN 50112-2: 2023-05 (p. 12.1) MBN 50112-4: 2024-06 (p. 12.1.3; 12.1.3.1) GS 95007-1-1:2013-05 (p. 9.1.2)","categories":["other"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Conductor diameter Range Conductor diameter Range: ISO 19642-2:2019-01 (p. 5.1.4) | ISO 19642-2:2023 (p. 5.2.3) | ISO 19642-3:2019-01 (p. 5.2.3) | ISO 19642-4:2019-01 (p. 5.2.3) | ISO 19642-5:2019-01 (p. 5.2.3) | ISO 19642-6:2019-01 (p. 5.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.3) | ISO 6722-2:2013-12-01 (p. 5.3.1) LV 112-1:2013-04 (p. 9.1.2) LV 112-1:2014-04 (p. 9.1.2) LV 112-2:2007-11 (p. 8.1) VW 60306-1:2018-09-01 (p. 9.1.2) VW 60306-1:2021-10 (p. 9.2.3) VW 60306-2:2013-04 (p. 9.1.2) VW 60306-2:2021-11 (p. 9.2.3) VW 60306-4:2021-12 (p. 9.2.3) MBN LV 112-1:2016-03 (p. 9.1.2) MBN 50112-1:2023-06 (p. 12.1.3) MBN LV 112-2:2012-01 (p. 8.1) MBN 50112-2: 2023-05 (p. 12.1) MBN 50112-4: 2024-06 (p. 12.1.3; 12.1.3.1) GS 95007-1-1:2013-05 (p. 9.1.2)","parameters_zh":[{"name":"范围","range":"(0,01 - 40) mm"},{"name":"Conductor diameter Range:","range":"(0,01 - 40) mm"}],"search_zh":"电缆 范围 ISO 19642-2:2019-01 (p. 5.1.4) | ISO 19642-2:2023 (p. 5.2.3) | ISO 19642-3:2019-01 (p. 5.2.3) | ISO 19642-4:2019-01 (p. 5.2.3) | ISO 19642-5:2019-01 (p. 5.2.3) | ISO 19642-6:2019-01 (p. 5.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.3) | ISO 6722-2:2013-12-01 (p. 5.3.1) LV 112-1:2013-04 (p. 9.1.2) LV 112-1:2014-04 (p. 9.1.2) LV 112-2:2007-11 (p. 8.1) VW 60306-1:2018-09-01 (p. 9.1.2) VW 60306-1:2021-10 (p. 9.2.3) VW 60306-2:2013-04 (p. 9.1.2) VW 60306-2:2021-11 (p. 9.2.3) VW 60306-4:2021-12 (p. 9.2.3) MBN LV 112-1:2016-03 (p. 9.1.2) MBN 50112-1:2023-06 (p. 12.1.3) MBN LV 112-2:2012-01 (p. 8.1) MBN 50112-2: 2023-05 (p. 12.1) MBN 50112-4: 2024-06 (p. 12.1.3; 12.1.3.1) GS 95007-1-1:2013-05 (p. 9.1.2)","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ec6","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Powierzchnia przekroju, Cross-sectional area (CSA)","methodology_en":"Cross-sectional area (CSA)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Powierzchnia przekroju, Cross-sectional area (CSA)","reference":"ISO 19642-2:2019-01 (p. 5.1.5) | ISO 19642-2:2023 (p. 5.2.4) | ISO 19642-3:2019-01 (p. 5.2.4) | ISO 19642-4:2019-01 (p. 5.2.4) | ISO 19642-5:2019-01 (p. 5.2.4) | ISO 19642-6:2019-01 (p. 5.2.4) | ISO 6722-2:2013-12-01 (p. 5.3.2) Scope of accreditation No. AB 1776","norm_bases":["ISO 19642-2:2019-01 (p. 5.1.5)","ISO 19642-2:2023 (p. 5.2.4)","ISO 19642-3:2019-01 (p. 5.2.4)","ISO 19642-4:2019-01 (p. 5.2.4)","ISO 19642-5:2019-01 (p. 5.2.4)","ISO 19642-6:2019-01 (p. 5.2.4)","ISO 6722-2:2013-12-01 (p. 5.3.2) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Powierzchnia przekroju, Cross-sectional area (CSA) ISO 19642-2:2019-01 (p. 5.1.5) | ISO 19642-2:2023 (p. 5.2.4) | ISO 19642-3:2019-01 (p. 5.2.4) | ISO 19642-4:2019-01 (p. 5.2.4) | ISO 19642-5:2019-01 (p. 5.2.4) | ISO 19642-6:2019-01 (p. 5.2.4) | ISO 6722-2:2013-12-01 (p. 5.3.2) Scope of accreditation No. AB 1776 Kable, Cables Powierzchnia przekroju, Cross-sectional area (CSA) ISO 19642-2:2019-01 (p. 5.1.5) | ISO 19642-2:2023 (p. 5.2.4) | ISO 19642-3:2019-01 (p. 5.2.4) | ISO 19642-4:2019-01 (p. 5.2.4) | ISO 19642-5:2019-01 (p. 5.2.4) | ISO 19642-6:2019-01 (p. 5.2.4) | ISO 6722-2:2013-12-01 (p. 5.3.2) Scope of accreditation No. AB 1776","categories":["other"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Cross-sectional area (CSA) ISO 19642-2:2019-01 (p. 5.1.5) | ISO 19642-2:2023 (p. 5.2.4) | ISO 19642-3:2019-01 (p. 5.2.4) | ISO 19642-4:2019-01 (p. 5.2.4) | ISO 19642-5:2019-01 (p. 5.2.4) | ISO 19642-6:2019-01 (p. 5.2.4) | ISO 6722-2:2013-12-01 (p. 5.3.2) Scope of accreditation No. AB 1776","search_zh":"电缆 ISO 19642-2:2019-01 (p. 5.1.5) | ISO 19642-2:2023 (p. 5.2.4) | ISO 19642-3:2019-01 (p. 5.2.4) | ISO 19642-4:2019-01 (p. 5.2.4) | ISO 19642-5:2019-01 (p. 5.2.4) | ISO 19642-6:2019-01 (p. 5.2.4) | ISO 6722-2:2013-12-01 (p. 5.3.2) Scope of accreditation No. AB 1776","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ec7","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Pomiar rezystancji:","methodology_en":"Resistance measurement:","parameters":[{"name":"przewodnika"},{"name":"ekranu"},{"name":"kabla skręconego"},{"name":"Miliomomierz","range":"10 μΩ do 10 kΩ"}],"parameters_en":[{"name":"conductor"},{"name":"screen"},{"name":"twisted cable"},{"name":"Milliohmmeter","range":"10 μΩ do 10 kΩ"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pomiar rezystancji:\nZakres:\nprzewodnika\nekranu\nkabla skręconego\nMiliomomierz 10 μΩ do 10 kΩ","reference":"ISO 19642-2:2019-01 (p. 5.2.1; 6.2.3.2) | ISO 19642-2:2023 (p. 5.3.1; 6.3.3.2) | ISO 19642-3:2019-01 (p. 5.3.1) | ISO 19642-4:2019-01 (p. 5.3.1) | ISO 19642-5:2019-01 (p. 5.3.1) | ISO 19642-6:2019-01 (p. 5.3.1) | ISO 19642-7:2019-01 (p. 6.3.3.2) | ISO 19642-8:2019-01 (p. 6.3.3.2) | ISO 19642-9:2019-01 (p. 6.3.3.2) | ISO 19642-10:2019-01 (p. 6.3.3.2) | ISO 6722-1:2011-10-15, corr.1:2012-09-15 (p. 5.4) | ISO 6722-2:2013-12-01 (p. 5.4) | ISO 14572:2011-10 (p. 5.6.2) LV 112-1:2013-04 (p. 9.1.3) LV 112-1:2014-04 (p. 9.1.3) LV 112-2:2007-11 (p. 8.2) LV 112-2:2013-04 (p. 9.1.3) LV 122:2015-05 (p. 11.4.1) LV 122:2016-02 (p. 11.5.1) VW 75205:2019-11 (p. 11.4.1) VW 75205:2023-05 (p. 11.4.1) VW 75205:2024-04 (p. 11.5.1) VW 60306-1:2018-09-01 (p. 9.1.3) VW 60306-1:2021-10 (p. 9.2.4) VW 60306-2:2013-04 (p. 9.1.3) VW 60306-2:2021-11 (p. 9.2.4) VW 60306-4:2021-12 (p. 9.2.4) MBN LV 112-1:2016-03 (p. 9.1.3) MBN 50112-1:2023-06 (p. 12.1.4) MBN LV 112-2:2012-01 (p. 8.2) MBN 50112-2: 2023-05 (p. 12.2) MBN LV 122:2017-06 (p. 11.5.1) MBN 50122:2023-07 (p. 13.5.1) MBN 50112-4:2024-06 (p. 12.1.4) GS 95007-1-1:2013-05 (p. 9.1.3) GS 95007-1-2:2013-05 (p. 9.1.3) GS 95007-1-5:2015-07 (p. 11.4.1) Scope of accreditation No. AB 1776","norm_bases":["ISO 19642-2:2019-01 (p. 5.2.1; 6.2.3.2)","ISO 19642-2:2023 (p. 5.3.1; 6.3.3.2)","ISO 19642-3:2019-01 (p. 5.3.1)","ISO 19642-4:2019-01 (p. 5.3.1)","ISO 19642-5:2019-01 (p. 5.3.1)","ISO 19642-6:2019-01 (p. 5.3.1)","ISO 19642-7:2019-01 (p. 6.3.3.2)","ISO 19642-8:2019-01 (p. 6.3.3.2)","ISO 19642-9:2019-01 (p. 6.3.3.2)","ISO 19642-10:2019-01 (p. 6.3.3.2)","ISO 6722-1:2011-10-15, corr.1:2012-09-15 (p. 5.4)","ISO 6722-2:2013-12-01 (p. 5.4)","ISO 14572:2011-10 (p. 5.6.2) LV 112-1:2013-04 (p. 9.1.3) LV 112-1:2014-04 (p. 9.1.3) LV 112-2:2007-11 (p. 8.2) LV 112-2:2013-04 (p. 9.1.3) LV 122:2015-05 (p. 11.4.1) LV 122:2016-02 (p. 11.5.1) VW 75205:2019-11 (p. 11.4.1) VW 75205:2023-05 (p. 11.4.1) VW 75205:2024-04 (p. 11.5.1) VW 60306-1:2018-09-01 (p. 9.1.3) VW 60306-1:2021-10 (p. 9.2.4) VW 60306-2:2013-04 (p. 9.1.3) VW 60306-2:2021-11 (p. 9.2.4) VW 60306-4:2021-12 (p. 9.2.4) MBN LV 112-1:2016-03 (p. 9.1.3) MBN 50112-1:2023-06 (p. 12.1.4) MBN LV 112-2:2012-01 (p. 8.2) MBN 50112-2: 2023-05 (p. 12.2) MBN LV 122:2017-06 (p. 11.5.1) MBN 50122:2023-07 (p. 13.5.1) MBN 50112-4:2024-06 (p. 12.1.4) GS 95007-1-1:2013-05 (p. 9.1.3) GS 95007-1-2:2013-05 (p. 9.1.3) GS 95007-1-5:2015-07 (p. 11.4.1) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Pomiar rezystancji:\nZakres:\nprzewodnika\nekranu\nkabla skręconego\nMiliomomierz 10 μΩ do 10 kΩ ISO 19642-2:2019-01 (p. 5.2.1; 6.2.3.2) | ISO 19642-2:2023 (p. 5.3.1; 6.3.3.2) | ISO 19642-3:2019-01 (p. 5.3.1) | ISO 19642-4:2019-01 (p. 5.3.1) | ISO 19642-5:2019-01 (p. 5.3.1) | ISO 19642-6:2019-01 (p. 5.3.1) | ISO 19642-7:2019-01 (p. 6.3.3.2) | ISO 19642-8:2019-01 (p. 6.3.3.2) | ISO 19642-9:2019-01 (p. 6.3.3.2) | ISO 19642-10:2019-01 (p. 6.3.3.2) | ISO 6722-1:2011-10-15, corr.1:2012-09-15 (p. 5.4) | ISO 6722-2:2013-12-01 (p. 5.4) | ISO 14572:2011-10 (p. 5.6.2) LV 112-1:2013-04 (p. 9.1.3) LV 112-1:2014-04 (p. 9.1.3) LV 112-2:2007-11 (p. 8.2) LV 112-2:2013-04 (p. 9.1.3) LV 122:2015-05 (p. 11.4.1) LV 122:2016-02 (p. 11.5.1) VW 75205:2019-11 (p. 11.4.1) VW 75205:2023-05 (p. 11.4.1) VW 75205:2024-04 (p. 11.5.1) VW 60306-1:2018-09-01 (p. 9.1.3) VW 60306-1:2021-10 (p. 9.2.4) VW 60306-2:2013-04 (p. 9.1.3) VW 60306-2:2021-11 (p. 9.2.4) VW 60306-4:2021-12 (p. 9.2.4) MBN LV 112-1:2016-03 (p. 9.1.3) MBN 50112-1:2023-06 (p. 12.1.4) MBN LV 112-2:2012-01 (p. 8.2) MBN 50112-2: 2023-05 (p. 12.2) MBN LV 122:2017-06 (p. 11.5.1) MBN 50122:2023-07 (p. 13.5.1) MBN 50112-4:2024-06 (p. 12.1.4) GS 95007-1-1:2013-05 (p. 9.1.3) GS 95007-1-2:2013-05 (p. 9.1.3) GS 95007-1-5:2015-07 (p. 11.4.1) Scope of accreditation No. AB 1776 Kable, Cables Pomiar rezystancji:\nZakres:\nprzewodnika\nekranu\nkabla skreconego\nMiliomomierz 10 μΩ do 10 kΩ ISO 19642-2:2019-01 (p. 5.2.1; 6.2.3.2) | ISO 19642-2:2023 (p. 5.3.1; 6.3.3.2) | ISO 19642-3:2019-01 (p. 5.3.1) | ISO 19642-4:2019-01 (p. 5.3.1) | ISO 19642-5:2019-01 (p. 5.3.1) | ISO 19642-6:2019-01 (p. 5.3.1) | ISO 19642-7:2019-01 (p. 6.3.3.2) | ISO 19642-8:2019-01 (p. 6.3.3.2) | ISO 19642-9:2019-01 (p. 6.3.3.2) | ISO 19642-10:2019-01 (p. 6.3.3.2) | ISO 6722-1:2011-10-15, corr.1:2012-09-15 (p. 5.4) | ISO 6722-2:2013-12-01 (p. 5.4) | ISO 14572:2011-10 (p. 5.6.2) LV 112-1:2013-04 (p. 9.1.3) LV 112-1:2014-04 (p. 9.1.3) LV 112-2:2007-11 (p. 8.2) LV 112-2:2013-04 (p. 9.1.3) LV 122:2015-05 (p. 11.4.1) LV 122:2016-02 (p. 11.5.1) VW 75205:2019-11 (p. 11.4.1) VW 75205:2023-05 (p. 11.4.1) VW 75205:2024-04 (p. 11.5.1) VW 60306-1:2018-09-01 (p. 9.1.3) VW 60306-1:2021-10 (p. 9.2.4) VW 60306-2:2013-04 (p. 9.1.3) VW 60306-2:2021-11 (p. 9.2.4) VW 60306-4:2021-12 (p. 9.2.4) MBN LV 112-1:2016-03 (p. 9.1.3) MBN 50112-1:2023-06 (p. 12.1.4) MBN LV 112-2:2012-01 (p. 8.2) MBN 50112-2: 2023-05 (p. 12.2) MBN LV 122:2017-06 (p. 11.5.1) MBN 50122:2023-07 (p. 13.5.1) MBN 50112-4:2024-06 (p. 12.1.4) GS 95007-1-1:2013-05 (p. 9.1.3) GS 95007-1-2:2013-05 (p. 9.1.3) GS 95007-1-5:2015-07 (p. 11.4.1) Scope of accreditation No. AB 1776","categories":["other"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Resistance measurement: conductor screen twisted cable Milliohmmeter ISO 19642-2:2019-01 (p. 5.2.1; 6.2.3.2) | ISO 19642-2:2023 (p. 5.3.1; 6.3.3.2) | ISO 19642-3:2019-01 (p. 5.3.1) | ISO 19642-4:2019-01 (p. 5.3.1) | ISO 19642-5:2019-01 (p. 5.3.1) | ISO 19642-6:2019-01 (p. 5.3.1) | ISO 19642-7:2019-01 (p. 6.3.3.2) | ISO 19642-8:2019-01 (p. 6.3.3.2) | ISO 19642-9:2019-01 (p. 6.3.3.2) | ISO 19642-10:2019-01 (p. 6.3.3.2) | ISO 6722-1:2011-10-15, corr.1:2012-09-15 (p. 5.4) | ISO 6722-2:2013-12-01 (p. 5.4) | ISO 14572:2011-10 (p. 5.6.2) LV 112-1:2013-04 (p. 9.1.3) LV 112-1:2014-04 (p. 9.1.3) LV 112-2:2007-11 (p. 8.2) LV 112-2:2013-04 (p. 9.1.3) LV 122:2015-05 (p. 11.4.1) LV 122:2016-02 (p. 11.5.1) VW 75205:2019-11 (p. 11.4.1) VW 75205:2023-05 (p. 11.4.1) VW 75205:2024-04 (p. 11.5.1) VW 60306-1:2018-09-01 (p. 9.1.3) VW 60306-1:2021-10 (p. 9.2.4) VW 60306-2:2013-04 (p. 9.1.3) VW 60306-2:2021-11 (p. 9.2.4) VW 60306-4:2021-12 (p. 9.2.4) MBN LV 112-1:2016-03 (p. 9.1.3) MBN 50112-1:2023-06 (p. 12.1.4) MBN LV 112-2:2012-01 (p. 8.2) MBN 50112-2: 2023-05 (p. 12.2) MBN LV 122:2017-06 (p. 11.5.1) MBN 50122:2023-07 (p. 13.5.1) MBN 50112-4:2024-06 (p. 12.1.4) GS 95007-1-1:2013-05 (p. 9.1.3) GS 95007-1-2:2013-05 (p. 9.1.3) GS 95007-1-5:2015-07 (p. 11.4.1) Scope of accreditation No. AB 1776","search_zh":"电缆 ISO 19642-2:2019-01 (p. 5.2.1; 6.2.3.2) | ISO 19642-2:2023 (p. 5.3.1; 6.3.3.2) | ISO 19642-3:2019-01 (p. 5.3.1) | ISO 19642-4:2019-01 (p. 5.3.1) | ISO 19642-5:2019-01 (p. 5.3.1) | ISO 19642-6:2019-01 (p. 5.3.1) | ISO 19642-7:2019-01 (p. 6.3.3.2) | ISO 19642-8:2019-01 (p. 6.3.3.2) | ISO 19642-9:2019-01 (p. 6.3.3.2) | ISO 19642-10:2019-01 (p. 6.3.3.2) | ISO 6722-1:2011-10-15, corr.1:2012-09-15 (p. 5.4) | ISO 6722-2:2013-12-01 (p. 5.4) | ISO 14572:2011-10 (p. 5.6.2) LV 112-1:2013-04 (p. 9.1.3) LV 112-1:2014-04 (p. 9.1.3) LV 112-2:2007-11 (p. 8.2) LV 112-2:2013-04 (p. 9.1.3) LV 122:2015-05 (p. 11.4.1) LV 122:2016-02 (p. 11.5.1) VW 75205:2019-11 (p. 11.4.1) VW 75205:2023-05 (p. 11.4.1) VW 75205:2024-04 (p. 11.5.1) VW 60306-1:2018-09-01 (p. 9.1.3) VW 60306-1:2021-10 (p. 9.2.4) VW 60306-2:2013-04 (p. 9.1.3) VW 60306-2:2021-11 (p. 9.2.4) VW 60306-4:2021-12 (p. 9.2.4) MBN LV 112-1:2016-03 (p. 9.1.3) MBN 50112-1:2023-06 (p. 12.1.4) MBN LV 112-2:2012-01 (p. 8.2) MBN 50112-2: 2023-05 (p. 12.2) MBN LV 122:2017-06 (p. 11.5.1) MBN 50122:2023-07 (p. 13.5.1) MBN 50112-4:2024-06 (p. 12.1.4) GS 95007-1-1:2013-05 (p. 9.1.3) GS 95007-1-2:2013-05 (p. 9.1.3) GS 95007-1-5:2015-07 (p. 11.4.1) Scope of accreditation No. AB 1776","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ec8","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Wytrzymałość napięciowa (30 minut)","methodology_en":"Voltage withstand (30 minutes)","parameters":[{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"5 kV do 10 kV A.C.","range":"(50 Hz)"},{"name":"0,5 kV do 6 kV D.C. Withstand voltage","range":"(30 min)"},{"name":"Range: 0,5 kV to 5 kV A.C.","range":"(50 Hz, 60 Hz)"},{"name":"5 kV do 10 kV A.C.","range":"(50 Hz)"}],"parameters_en":[{"name":"Range","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"5 kV to 10 kV A.C.","range":"(50 Hz)"},{"name":"0,5 kV to 6 kV D.C. Withstand voltage","range":"(30 min)"},{"name":"Range: 0,5 kV to 5 kV A.C.","range":"(50 Hz, 60 Hz)"},{"name":"5 kV to 10 kV A.C.","range":"(50 Hz)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość napięciowa (30 minut)\nZakres:\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n5 kV do 10 kV A.C. (50 Hz)\n0,5 kV do 6 kV D.C. Withstand voltage (30 min)\nRange: 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\n5 kV do 10 kV A.C. (50 Hz)","reference":"ISO 19642-2:2019-01 (p. 5.2.3) | ISO 19642-2:2023 (p. 5.3.3) | ISO 19642-3:2019-01 (p. 5.3.3) | ISO 19642-4:2019-01 (p. 5.3.3) | ISO 19642-5:2019-01 (p. 5.3.3) | ISO 19642-6:2019-01 (p. 5.3.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.5) | ISO 6722-2 2013-12-01 (p. 5.5) LV 112-1:2013-04 (p. 9.5.2) LV 112-1:2014-04 (p. 9.5.2) LV 112-2:2007-11 (p. 8.6) LV 112-2:2013-04 (p. 9.5.2) LV 122:2015-05 (p. 11.4.3) LV 122:2016-02 (p. 11.5.3) LV 212-1:2015-01 (p. 9.5.3) LV 212-2:2015-01 (9.5.2) LV 212-2:2015-01 (p. 9.5.3) LV 216-1:2015-07 (p. 9.5.2) LV 216-2:2017-02 (p. 9.5.2) VW 60306-1:2018-09-01 (p. 9.5.2) VW 60306-1:2021-10 (p. 9.6.2) VW 60306-2:2013-04 (p. 9.5.2) VW 60306-2:2021-11 (p. 9.6.2) VW 60306-4:2021-12 (p. 9.6.2) VW 75205:2019-11 (p. 11.4.3) VW 75205:2023-05 (p. 11.4.3) VW 75205:2024-04 (p. 11.5.3) VW 75209-1:2015-01 (p. 9.5.2) VW 75209-2:2015-01 (p. 9.5.2) VW 75209-2:2015-01 (p. 9.5.2) VW 75209-2:2021-12 (p. 9.6.1) VW 75210-1:2023-06 (p. 9.6.2) VW 75210-1:2024-08 (p. 9.6.2) VW 75210-2:2023-06 (p. 9.6.2) MBN LV 112-1:2016-03 (p. 9.5.2) MBN 50112-1:2023-06 (p. 12.5.2) MBN LV 112-2:2012-01 (p. 8.6) MBN 50112-2: 2023-05 (p. 12.6) MBN 50216-1:2023-07 (p. 12.6.2) MBN LV 122:2017-06 (p. 11.5.3) MBN 50122:2023-07 (p. 13.5.3) MBN LV 212-1:2017-08 (p. 9.5.3) MBN LV 216-2:2017-07 (p. 9.5.2) MBN 50112-4:2024-06 (p. 12.5.2) GS 95007-1-1:2013-05 (p. 9.5.2) GS 95007-1-2:2013-05 (p. 9.5.2) GS 95007-6-1:2016-03 (p. 9.5.2) GS 95007-6-2:2017-04 (p. 9.5.2) GS 95007-1-5:2015-07 (p. 11.4.3) GS 95007-3-1:2015-08 (p. 9.5.3) GS 95007-3-2:2015-09 (p. 9.5.2; 9.5.3) Scope of accreditation No. AB 1776","norm_bases":["ISO 19642-2:2019-01 (p. 5.2.3)","ISO 19642-2:2023 (p. 5.3.3)","ISO 19642-3:2019-01 (p. 5.3.3)","ISO 19642-4:2019-01 (p. 5.3.3)","ISO 19642-5:2019-01 (p. 5.3.3)","ISO 19642-6:2019-01 (p. 5.3.3)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.5)","ISO 6722-2 2013-12-01 (p. 5.5) LV 112-1:2013-04 (p. 9.5.2) LV 112-1:2014-04 (p. 9.5.2) LV 112-2:2007-11 (p. 8.6) LV 112-2:2013-04 (p. 9.5.2) LV 122:2015-05 (p. 11.4.3) LV 122:2016-02 (p. 11.5.3) LV 212-1:2015-01 (p. 9.5.3) LV 212-2:2015-01 (9.5.2) LV 212-2:2015-01 (p. 9.5.3) LV 216-1:2015-07 (p. 9.5.2) LV 216-2:2017-02 (p. 9.5.2) VW 60306-1:2018-09-01 (p. 9.5.2) VW 60306-1:2021-10 (p. 9.6.2) VW 60306-2:2013-04 (p. 9.5.2) VW 60306-2:2021-11 (p. 9.6.2) VW 60306-4:2021-12 (p. 9.6.2) VW 75205:2019-11 (p. 11.4.3) VW 75205:2023-05 (p. 11.4.3) VW 75205:2024-04 (p. 11.5.3) VW 75209-1:2015-01 (p. 9.5.2) VW 75209-2:2015-01 (p. 9.5.2) VW 75209-2:2015-01 (p. 9.5.2) VW 75209-2:2021-12 (p. 9.6.1) VW 75210-1:2023-06 (p. 9.6.2) VW 75210-1:2024-08 (p. 9.6.2) VW 75210-2:2023-06 (p. 9.6.2) MBN LV 112-1:2016-03 (p. 9.5.2) MBN 50112-1:2023-06 (p. 12.5.2) MBN LV 112-2:2012-01 (p. 8.6) MBN 50112-2: 2023-05 (p. 12.6) MBN 50216-1:2023-07 (p. 12.6.2) MBN LV 122:2017-06 (p. 11.5.3) MBN 50122:2023-07 (p. 13.5.3) MBN LV 212-1:2017-08 (p. 9.5.3) MBN LV 216-2:2017-07 (p. 9.5.2) MBN 50112-4:2024-06 (p. 12.5.2) GS 95007-1-1:2013-05 (p. 9.5.2) GS 95007-1-2:2013-05 (p. 9.5.2) GS 95007-6-1:2016-03 (p. 9.5.2) GS 95007-6-2:2017-04 (p. 9.5.2) GS 95007-1-5:2015-07 (p. 11.4.3) GS 95007-3-1:2015-08 (p. 9.5.3) GS 95007-3-2:2015-09 (p. 9.5.2; 9.5.3) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Wytrzymałość napięciowa (30 minut)\nZakres:\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n5 kV do 10 kV A.C. (50 Hz)\n0,5 kV do 6 kV D.C. Withstand voltage (30 min)\nRange: 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\n5 kV do 10 kV A.C. (50 Hz) ISO 19642-2:2019-01 (p. 5.2.3) | ISO 19642-2:2023 (p. 5.3.3) | ISO 19642-3:2019-01 (p. 5.3.3) | ISO 19642-4:2019-01 (p. 5.3.3) | ISO 19642-5:2019-01 (p. 5.3.3) | ISO 19642-6:2019-01 (p. 5.3.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.5) | ISO 6722-2 2013-12-01 (p. 5.5) LV 112-1:2013-04 (p. 9.5.2) LV 112-1:2014-04 (p. 9.5.2) LV 112-2:2007-11 (p. 8.6) LV 112-2:2013-04 (p. 9.5.2) LV 122:2015-05 (p. 11.4.3) LV 122:2016-02 (p. 11.5.3) LV 212-1:2015-01 (p. 9.5.3) LV 212-2:2015-01 (9.5.2) LV 212-2:2015-01 (p. 9.5.3) LV 216-1:2015-07 (p. 9.5.2) LV 216-2:2017-02 (p. 9.5.2) VW 60306-1:2018-09-01 (p. 9.5.2) VW 60306-1:2021-10 (p. 9.6.2) VW 60306-2:2013-04 (p. 9.5.2) VW 60306-2:2021-11 (p. 9.6.2) VW 60306-4:2021-12 (p. 9.6.2) VW 75205:2019-11 (p. 11.4.3) VW 75205:2023-05 (p. 11.4.3) VW 75205:2024-04 (p. 11.5.3) VW 75209-1:2015-01 (p. 9.5.2) VW 75209-2:2015-01 (p. 9.5.2) VW 75209-2:2015-01 (p. 9.5.2) VW 75209-2:2021-12 (p. 9.6.1) VW 75210-1:2023-06 (p. 9.6.2) VW 75210-1:2024-08 (p. 9.6.2) VW 75210-2:2023-06 (p. 9.6.2) MBN LV 112-1:2016-03 (p. 9.5.2) MBN 50112-1:2023-06 (p. 12.5.2) MBN LV 112-2:2012-01 (p. 8.6) MBN 50112-2: 2023-05 (p. 12.6) MBN 50216-1:2023-07 (p. 12.6.2) MBN LV 122:2017-06 (p. 11.5.3) MBN 50122:2023-07 (p. 13.5.3) MBN LV 212-1:2017-08 (p. 9.5.3) MBN LV 216-2:2017-07 (p. 9.5.2) MBN 50112-4:2024-06 (p. 12.5.2) GS 95007-1-1:2013-05 (p. 9.5.2) GS 95007-1-2:2013-05 (p. 9.5.2) GS 95007-6-1:2016-03 (p. 9.5.2) GS 95007-6-2:2017-04 (p. 9.5.2) GS 95007-1-5:2015-07 (p. 11.4.3) GS 95007-3-1:2015-08 (p. 9.5.3) GS 95007-3-2:2015-09 (p. 9.5.2; 9.5.3) Scope of accreditation No. AB 1776 Kable, Cables Wytrzymalosc napieciowa (30 minut)\nZakres:\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n5 kV do 10 kV A.C. (50 Hz)\n0,5 kV do 6 kV D.C. Withstand voltage (30 min)\nRange: 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\n5 kV do 10 kV A.C. (50 Hz) ISO 19642-2:2019-01 (p. 5.2.3) | ISO 19642-2:2023 (p. 5.3.3) | ISO 19642-3:2019-01 (p. 5.3.3) | ISO 19642-4:2019-01 (p. 5.3.3) | ISO 19642-5:2019-01 (p. 5.3.3) | ISO 19642-6:2019-01 (p. 5.3.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.5) | ISO 6722-2 2013-12-01 (p. 5.5) LV 112-1:2013-04 (p. 9.5.2) LV 112-1:2014-04 (p. 9.5.2) LV 112-2:2007-11 (p. 8.6) LV 112-2:2013-04 (p. 9.5.2) LV 122:2015-05 (p. 11.4.3) LV 122:2016-02 (p. 11.5.3) LV 212-1:2015-01 (p. 9.5.3) LV 212-2:2015-01 (9.5.2) LV 212-2:2015-01 (p. 9.5.3) LV 216-1:2015-07 (p. 9.5.2) LV 216-2:2017-02 (p. 9.5.2) VW 60306-1:2018-09-01 (p. 9.5.2) VW 60306-1:2021-10 (p. 9.6.2) VW 60306-2:2013-04 (p. 9.5.2) VW 60306-2:2021-11 (p. 9.6.2) VW 60306-4:2021-12 (p. 9.6.2) VW 75205:2019-11 (p. 11.4.3) VW 75205:2023-05 (p. 11.4.3) VW 75205:2024-04 (p. 11.5.3) VW 75209-1:2015-01 (p. 9.5.2) VW 75209-2:2015-01 (p. 9.5.2) VW 75209-2:2015-01 (p. 9.5.2) VW 75209-2:2021-12 (p. 9.6.1) VW 75210-1:2023-06 (p. 9.6.2) VW 75210-1:2024-08 (p. 9.6.2) VW 75210-2:2023-06 (p. 9.6.2) MBN LV 112-1:2016-03 (p. 9.5.2) MBN 50112-1:2023-06 (p. 12.5.2) MBN LV 112-2:2012-01 (p. 8.6) MBN 50112-2: 2023-05 (p. 12.6) MBN 50216-1:2023-07 (p. 12.6.2) MBN LV 122:2017-06 (p. 11.5.3) MBN 50122:2023-07 (p. 13.5.3) MBN LV 212-1:2017-08 (p. 9.5.3) MBN LV 216-2:2017-07 (p. 9.5.2) MBN 50112-4:2024-06 (p. 12.5.2) GS 95007-1-1:2013-05 (p. 9.5.2) GS 95007-1-2:2013-05 (p. 9.5.2) GS 95007-6-1:2016-03 (p. 9.5.2) GS 95007-6-2:2017-04 (p. 9.5.2) GS 95007-1-5:2015-07 (p. 11.4.3) GS 95007-3-1:2015-08 (p. 9.5.3) GS 95007-3-2:2015-09 (p. 9.5.2; 9.5.3) Scope of accreditation No. AB 1776","categories":["other"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Voltage withstand (30 minutes) Range 5 kV to 10 kV A.C. 0,5 kV to 6 kV D.C. Withstand voltage Range: 0,5 kV to 5 kV A.C. 5 kV to 10 kV A.C. ISO 19642-2:2019-01 (p. 5.2.3) | ISO 19642-2:2023 (p. 5.3.3) | ISO 19642-3:2019-01 (p. 5.3.3) | ISO 19642-4:2019-01 (p. 5.3.3) | ISO 19642-5:2019-01 (p. 5.3.3) | ISO 19642-6:2019-01 (p. 5.3.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.5) | ISO 6722-2 2013-12-01 (p. 5.5) LV 112-1:2013-04 (p. 9.5.2) LV 112-1:2014-04 (p. 9.5.2) LV 112-2:2007-11 (p. 8.6) LV 112-2:2013-04 (p. 9.5.2) LV 122:2015-05 (p. 11.4.3) LV 122:2016-02 (p. 11.5.3) LV 212-1:2015-01 (p. 9.5.3) LV 212-2:2015-01 (9.5.2) LV 212-2:2015-01 (p. 9.5.3) LV 216-1:2015-07 (p. 9.5.2) LV 216-2:2017-02 (p. 9.5.2) VW 60306-1:2018-09-01 (p. 9.5.2) VW 60306-1:2021-10 (p. 9.6.2) VW 60306-2:2013-04 (p. 9.5.2) VW 60306-2:2021-11 (p. 9.6.2) VW 60306-4:2021-12 (p. 9.6.2) VW 75205:2019-11 (p. 11.4.3) VW 75205:2023-05 (p. 11.4.3) VW 75205:2024-04 (p. 11.5.3) VW 75209-1:2015-01 (p. 9.5.2) VW 75209-2:2015-01 (p. 9.5.2) VW 75209-2:2015-01 (p. 9.5.2) VW 75209-2:2021-12 (p. 9.6.1) VW 75210-1:2023-06 (p. 9.6.2) VW 75210-1:2024-08 (p. 9.6.2) VW 75210-2:2023-06 (p. 9.6.2) MBN LV 112-1:2016-03 (p. 9.5.2) MBN 50112-1:2023-06 (p. 12.5.2) MBN LV 112-2:2012-01 (p. 8.6) MBN 50112-2: 2023-05 (p. 12.6) MBN 50216-1:2023-07 (p. 12.6.2) MBN LV 122:2017-06 (p. 11.5.3) MBN 50122:2023-07 (p. 13.5.3) MBN LV 212-1:2017-08 (p. 9.5.3) MBN LV 216-2:2017-07 (p. 9.5.2) MBN 50112-4:2024-06 (p. 12.5.2) GS 95007-1-1:2013-05 (p. 9.5.2) GS 95007-1-2:2013-05 (p. 9.5.2) GS 95007-6-1:2016-03 (p. 9.5.2) GS 95007-6-2:2017-04 (p. 9.5.2) GS 95007-1-5:2015-07 (p. 11.4.3) GS 95007-3-1:2015-08 (p. 9.5.3) GS 95007-3-2:2015-09 (p. 9.5.2; 9.5.3) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"范围","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"5 kV do 10 kV A.C.","range":"(50 Hz)"},{"name":"0,5 kV do 6 kV D.C. Withstand voltage","range":"(30 min)"},{"name":"Range: 0,5 kV to 5 kV A.C.","range":"(50 Hz, 60 Hz)"},{"name":"5 kV do 10 kV A.C.","range":"(50 Hz)"}],"search_zh":"电缆 范围 ISO 19642-2:2019-01 (p. 5.2.3) | ISO 19642-2:2023 (p. 5.3.3) | ISO 19642-3:2019-01 (p. 5.3.3) | ISO 19642-4:2019-01 (p. 5.3.3) | ISO 19642-5:2019-01 (p. 5.3.3) | ISO 19642-6:2019-01 (p. 5.3.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.5) | ISO 6722-2 2013-12-01 (p. 5.5) LV 112-1:2013-04 (p. 9.5.2) LV 112-1:2014-04 (p. 9.5.2) LV 112-2:2007-11 (p. 8.6) LV 112-2:2013-04 (p. 9.5.2) LV 122:2015-05 (p. 11.4.3) LV 122:2016-02 (p. 11.5.3) LV 212-1:2015-01 (p. 9.5.3) LV 212-2:2015-01 (9.5.2) LV 212-2:2015-01 (p. 9.5.3) LV 216-1:2015-07 (p. 9.5.2) LV 216-2:2017-02 (p. 9.5.2) VW 60306-1:2018-09-01 (p. 9.5.2) VW 60306-1:2021-10 (p. 9.6.2) VW 60306-2:2013-04 (p. 9.5.2) VW 60306-2:2021-11 (p. 9.6.2) VW 60306-4:2021-12 (p. 9.6.2) VW 75205:2019-11 (p. 11.4.3) VW 75205:2023-05 (p. 11.4.3) VW 75205:2024-04 (p. 11.5.3) VW 75209-1:2015-01 (p. 9.5.2) VW 75209-2:2015-01 (p. 9.5.2) VW 75209-2:2015-01 (p. 9.5.2) VW 75209-2:2021-12 (p. 9.6.1) VW 75210-1:2023-06 (p. 9.6.2) VW 75210-1:2024-08 (p. 9.6.2) VW 75210-2:2023-06 (p. 9.6.2) MBN LV 112-1:2016-03 (p. 9.5.2) MBN 50112-1:2023-06 (p. 12.5.2) MBN LV 112-2:2012-01 (p. 8.6) MBN 50112-2: 2023-05 (p. 12.6) MBN 50216-1:2023-07 (p. 12.6.2) MBN LV 122:2017-06 (p. 11.5.3) MBN 50122:2023-07 (p. 13.5.3) MBN LV 212-1:2017-08 (p. 9.5.3) MBN LV 216-2:2017-07 (p. 9.5.2) MBN 50112-4:2024-06 (p. 12.5.2) GS 95007-1-1:2013-05 (p. 9.5.2) GS 95007-1-2:2013-05 (p. 9.5.2) GS 95007-6-1:2016-03 (p. 9.5.2) GS 95007-6-2:2017-04 (p. 9.5.2) GS 95007-1-5:2015-07 (p. 11.4.3) GS 95007-3-1:2015-08 (p. 9.5.3) GS 95007-3-2:2015-09 (p. 9.5.2; 9.5.3) Scope of accreditation No. AB 1776","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ec9","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Wytrzymałość napięciowa po testach środowiskowych (1 minuta)","methodology_en":"Voltage withstand after environmental tests (1 minute)","parameters":[{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"5 kV do 10 kV A.C.","range":"(50 Hz)"},{"name":"0,5 kV do 6 kV D.C. Withstand voltage after environmental testing","range":"(1 minute)"},{"name":"Range: 0,5 kV to 5 kV A.C.","range":"(50 Hz, 60 Hz)"},{"name":"5 kV do 10 kV A.C.","range":"(50 Hz)"}],"parameters_en":[{"name":"Range","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"5 kV to 10 kV A.C.","range":"(50 Hz)"},{"name":"0,5 kV to 6 kV D.C. Withstand voltage after environmental testing","range":"(1 minute)"},{"name":"Range: 0,5 kV to 5 kV A.C.","range":"(50 Hz, 60 Hz)"},{"name":"5 kV to 10 kV A.C.","range":"(50 Hz)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość napięciowa po testach środowiskowych (1 minuta)\nZakres:\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n5 kV do 10 kV A.C. (50 Hz)\n0,5 kV do 6 kV D.C. Withstand voltage after environmental testing (1 minute)\nRange: 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\n5 kV do 10 kV A.C. (50 Hz)","reference":"ISO 19642-2:2019-01 (p. 5.2.4; 6.2.2) | ISO 19642-2:2023 (p. 5.3.4; 6.3.2) | ISO 19642-3:2019-01 (p. 5.3.4) | ISO 19642-4:2019-01 (p. 5.3.4) | ISO 19642-5:2019-01 (p. 5.3.4) | ISO 19642-6:2019-01 (p. 5.3.4) | ISO 19642-7:2019-01 (p. 6.3.2) | ISO 19642-8:2019-01 (p. 6.3.2) | ISO 19642-9:2019-01 (p. 6.3.2) | ISO 19642-10:2019-01 (p. 6.3.2) | ISO 14572:2011-10 (p. 5.5) LV 112-1:2013-04 (p. 9.5.3) LV 112-1:2014-04 (p. 9.5.3) LV 112-2:2007-11 (p. 8.6) LV 112-2:2013-04 (p. 9.5.3) LV 122:2015-05 (p. 11.4.4) LV 122:2016-02 (p. 11.5.4) LV 216-1:2015-07 (p. 9.5.3) LV 216-2:2017-02 (p. 9.5.3) VW 60306-1:2018-09-01 (p. 9.5.3) VW 60306-1:2021-10 (p. 9.6.3) VW 60306-2:2013-04 (p. 9.5.3) VW 60306-2:2021-11 (p. 9.6.3) VW 60306-4:2021-12 (p. 9.6.3) VW 75209-1:2015-01 (p. 9.5.3) VW 75209-1:2021-12 (p. 9.6.2) VW 75209-2:2015-01 (p. 9.5.3) VW 75209-2:2021-12 (p. 9.6.2) VW 75210-1:2023-06 (p. 9.6.3) VW 75210-1:2024-08 (p. 9.6.3) VW 75210-2:2023-06 (p. 9.6.3) MBN LV 112-1:2016-03 (p. 9.5.3) MBN 50112-1:2023-06 (p. 12.5.3) MBN LV 112-2:2012-01 (p. 8.6) MBN 50112-2: 2023-05 (p. 12.6) MBN 50216-1:2023-07 (p. 12.6.3) MBN LV 122:2017-06 (p. 11.5.4) MBN 50122:2023-07 (p. 13.5.4) MBN 50212-1:2023-04 (p. 12.6.3) MBN LV 216-2:2017-07 (p. 9.5.3) MBN 50112-4:2024-06 (p. 12.5.3) GS 95007-1-1:2013-05 (p. 9.5.3) GS 95007-1-2:2013-05 (p. 9.5.3) GS 95007-1-5:2015-07 (p. 11.4.4) GS 95007-6-1:2016-03 (p. 9.5.3) GS 95007-6-2:2017-04 (p. 9.5.3) Scope of accreditation No. AB 1776","norm_bases":["ISO 19642-2:2019-01 (p. 5.2.4; 6.2.2)","ISO 19642-2:2023 (p. 5.3.4; 6.3.2)","ISO 19642-3:2019-01 (p. 5.3.4)","ISO 19642-4:2019-01 (p. 5.3.4)","ISO 19642-5:2019-01 (p. 5.3.4)","ISO 19642-6:2019-01 (p. 5.3.4)","ISO 19642-7:2019-01 (p. 6.3.2)","ISO 19642-8:2019-01 (p. 6.3.2)","ISO 19642-9:2019-01 (p. 6.3.2)","ISO 19642-10:2019-01 (p. 6.3.2)","ISO 14572:2011-10 (p. 5.5) LV 112-1:2013-04 (p. 9.5.3) LV 112-1:2014-04 (p. 9.5.3) LV 112-2:2007-11 (p. 8.6) LV 112-2:2013-04 (p. 9.5.3) LV 122:2015-05 (p. 11.4.4) LV 122:2016-02 (p. 11.5.4) LV 216-1:2015-07 (p. 9.5.3) LV 216-2:2017-02 (p. 9.5.3) VW 60306-1:2018-09-01 (p. 9.5.3) VW 60306-1:2021-10 (p. 9.6.3) VW 60306-2:2013-04 (p. 9.5.3) VW 60306-2:2021-11 (p. 9.6.3) VW 60306-4:2021-12 (p. 9.6.3) VW 75209-1:2015-01 (p. 9.5.3) VW 75209-1:2021-12 (p. 9.6.2) VW 75209-2:2015-01 (p. 9.5.3) VW 75209-2:2021-12 (p. 9.6.2) VW 75210-1:2023-06 (p. 9.6.3) VW 75210-1:2024-08 (p. 9.6.3) VW 75210-2:2023-06 (p. 9.6.3) MBN LV 112-1:2016-03 (p. 9.5.3) MBN 50112-1:2023-06 (p. 12.5.3) MBN LV 112-2:2012-01 (p. 8.6) MBN 50112-2: 2023-05 (p. 12.6) MBN 50216-1:2023-07 (p. 12.6.3) MBN LV 122:2017-06 (p. 11.5.4) MBN 50122:2023-07 (p. 13.5.4) MBN 50212-1:2023-04 (p. 12.6.3) MBN LV 216-2:2017-07 (p. 9.5.3) MBN 50112-4:2024-06 (p. 12.5.3) GS 95007-1-1:2013-05 (p. 9.5.3) GS 95007-1-2:2013-05 (p. 9.5.3) GS 95007-1-5:2015-07 (p. 11.4.4) GS 95007-6-1:2016-03 (p. 9.5.3) GS 95007-6-2:2017-04 (p. 9.5.3) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Wytrzymałość napięciowa po testach środowiskowych (1 minuta)\nZakres:\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n5 kV do 10 kV A.C. (50 Hz)\n0,5 kV do 6 kV D.C. Withstand voltage after environmental testing (1 minute)\nRange: 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\n5 kV do 10 kV A.C. (50 Hz) ISO 19642-2:2019-01 (p. 5.2.4; 6.2.2) | ISO 19642-2:2023 (p. 5.3.4; 6.3.2) | ISO 19642-3:2019-01 (p. 5.3.4) | ISO 19642-4:2019-01 (p. 5.3.4) | ISO 19642-5:2019-01 (p. 5.3.4) | ISO 19642-6:2019-01 (p. 5.3.4) | ISO 19642-7:2019-01 (p. 6.3.2) | ISO 19642-8:2019-01 (p. 6.3.2) | ISO 19642-9:2019-01 (p. 6.3.2) | ISO 19642-10:2019-01 (p. 6.3.2) | ISO 14572:2011-10 (p. 5.5) LV 112-1:2013-04 (p. 9.5.3) LV 112-1:2014-04 (p. 9.5.3) LV 112-2:2007-11 (p. 8.6) LV 112-2:2013-04 (p. 9.5.3) LV 122:2015-05 (p. 11.4.4) LV 122:2016-02 (p. 11.5.4) LV 216-1:2015-07 (p. 9.5.3) LV 216-2:2017-02 (p. 9.5.3) VW 60306-1:2018-09-01 (p. 9.5.3) VW 60306-1:2021-10 (p. 9.6.3) VW 60306-2:2013-04 (p. 9.5.3) VW 60306-2:2021-11 (p. 9.6.3) VW 60306-4:2021-12 (p. 9.6.3) VW 75209-1:2015-01 (p. 9.5.3) VW 75209-1:2021-12 (p. 9.6.2) VW 75209-2:2015-01 (p. 9.5.3) VW 75209-2:2021-12 (p. 9.6.2) VW 75210-1:2023-06 (p. 9.6.3) VW 75210-1:2024-08 (p. 9.6.3) VW 75210-2:2023-06 (p. 9.6.3) MBN LV 112-1:2016-03 (p. 9.5.3) MBN 50112-1:2023-06 (p. 12.5.3) MBN LV 112-2:2012-01 (p. 8.6) MBN 50112-2: 2023-05 (p. 12.6) MBN 50216-1:2023-07 (p. 12.6.3) MBN LV 122:2017-06 (p. 11.5.4) MBN 50122:2023-07 (p. 13.5.4) MBN 50212-1:2023-04 (p. 12.6.3) MBN LV 216-2:2017-07 (p. 9.5.3) MBN 50112-4:2024-06 (p. 12.5.3) GS 95007-1-1:2013-05 (p. 9.5.3) GS 95007-1-2:2013-05 (p. 9.5.3) GS 95007-1-5:2015-07 (p. 11.4.4) GS 95007-6-1:2016-03 (p. 9.5.3) GS 95007-6-2:2017-04 (p. 9.5.3) Scope of accreditation No. AB 1776 Kable, Cables Wytrzymalosc napieciowa po testach srodowiskowych (1 minuta)\nZakres:\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n5 kV do 10 kV A.C. (50 Hz)\n0,5 kV do 6 kV D.C. Withstand voltage after environmental testing (1 minute)\nRange: 0,5 kV to 5 kV A.C. (50 Hz, 60 Hz)\n5 kV do 10 kV A.C. (50 Hz) ISO 19642-2:2019-01 (p. 5.2.4; 6.2.2) | ISO 19642-2:2023 (p. 5.3.4; 6.3.2) | ISO 19642-3:2019-01 (p. 5.3.4) | ISO 19642-4:2019-01 (p. 5.3.4) | ISO 19642-5:2019-01 (p. 5.3.4) | ISO 19642-6:2019-01 (p. 5.3.4) | ISO 19642-7:2019-01 (p. 6.3.2) | ISO 19642-8:2019-01 (p. 6.3.2) | ISO 19642-9:2019-01 (p. 6.3.2) | ISO 19642-10:2019-01 (p. 6.3.2) | ISO 14572:2011-10 (p. 5.5) LV 112-1:2013-04 (p. 9.5.3) LV 112-1:2014-04 (p. 9.5.3) LV 112-2:2007-11 (p. 8.6) LV 112-2:2013-04 (p. 9.5.3) LV 122:2015-05 (p. 11.4.4) LV 122:2016-02 (p. 11.5.4) LV 216-1:2015-07 (p. 9.5.3) LV 216-2:2017-02 (p. 9.5.3) VW 60306-1:2018-09-01 (p. 9.5.3) VW 60306-1:2021-10 (p. 9.6.3) VW 60306-2:2013-04 (p. 9.5.3) VW 60306-2:2021-11 (p. 9.6.3) VW 60306-4:2021-12 (p. 9.6.3) VW 75209-1:2015-01 (p. 9.5.3) VW 75209-1:2021-12 (p. 9.6.2) VW 75209-2:2015-01 (p. 9.5.3) VW 75209-2:2021-12 (p. 9.6.2) VW 75210-1:2023-06 (p. 9.6.3) VW 75210-1:2024-08 (p. 9.6.3) VW 75210-2:2023-06 (p. 9.6.3) MBN LV 112-1:2016-03 (p. 9.5.3) MBN 50112-1:2023-06 (p. 12.5.3) MBN LV 112-2:2012-01 (p. 8.6) MBN 50112-2: 2023-05 (p. 12.6) MBN 50216-1:2023-07 (p. 12.6.3) MBN LV 122:2017-06 (p. 11.5.4) MBN 50122:2023-07 (p. 13.5.4) MBN 50212-1:2023-04 (p. 12.6.3) MBN LV 216-2:2017-07 (p. 9.5.3) MBN 50112-4:2024-06 (p. 12.5.3) GS 95007-1-1:2013-05 (p. 9.5.3) GS 95007-1-2:2013-05 (p. 9.5.3) GS 95007-1-5:2015-07 (p. 11.4.4) GS 95007-6-1:2016-03 (p. 9.5.3) GS 95007-6-2:2017-04 (p. 9.5.3) Scope of accreditation No. AB 1776","categories":["environment"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Voltage withstand after environmental tests (1 minute) Range 5 kV to 10 kV A.C. 0,5 kV to 6 kV D.C. Withstand voltage after environmental testing Range: 0,5 kV to 5 kV A.C. 5 kV to 10 kV A.C. ISO 19642-2:2019-01 (p. 5.2.4; 6.2.2) | ISO 19642-2:2023 (p. 5.3.4; 6.3.2) | ISO 19642-3:2019-01 (p. 5.3.4) | ISO 19642-4:2019-01 (p. 5.3.4) | ISO 19642-5:2019-01 (p. 5.3.4) | ISO 19642-6:2019-01 (p. 5.3.4) | ISO 19642-7:2019-01 (p. 6.3.2) | ISO 19642-8:2019-01 (p. 6.3.2) | ISO 19642-9:2019-01 (p. 6.3.2) | ISO 19642-10:2019-01 (p. 6.3.2) | ISO 14572:2011-10 (p. 5.5) LV 112-1:2013-04 (p. 9.5.3) LV 112-1:2014-04 (p. 9.5.3) LV 112-2:2007-11 (p. 8.6) LV 112-2:2013-04 (p. 9.5.3) LV 122:2015-05 (p. 11.4.4) LV 122:2016-02 (p. 11.5.4) LV 216-1:2015-07 (p. 9.5.3) LV 216-2:2017-02 (p. 9.5.3) VW 60306-1:2018-09-01 (p. 9.5.3) VW 60306-1:2021-10 (p. 9.6.3) VW 60306-2:2013-04 (p. 9.5.3) VW 60306-2:2021-11 (p. 9.6.3) VW 60306-4:2021-12 (p. 9.6.3) VW 75209-1:2015-01 (p. 9.5.3) VW 75209-1:2021-12 (p. 9.6.2) VW 75209-2:2015-01 (p. 9.5.3) VW 75209-2:2021-12 (p. 9.6.2) VW 75210-1:2023-06 (p. 9.6.3) VW 75210-1:2024-08 (p. 9.6.3) VW 75210-2:2023-06 (p. 9.6.3) MBN LV 112-1:2016-03 (p. 9.5.3) MBN 50112-1:2023-06 (p. 12.5.3) MBN LV 112-2:2012-01 (p. 8.6) MBN 50112-2: 2023-05 (p. 12.6) MBN 50216-1:2023-07 (p. 12.6.3) MBN LV 122:2017-06 (p. 11.5.4) MBN 50122:2023-07 (p. 13.5.4) MBN 50212-1:2023-04 (p. 12.6.3) MBN LV 216-2:2017-07 (p. 9.5.3) MBN 50112-4:2024-06 (p. 12.5.3) GS 95007-1-1:2013-05 (p. 9.5.3) GS 95007-1-2:2013-05 (p. 9.5.3) GS 95007-1-5:2015-07 (p. 11.4.4) GS 95007-6-1:2016-03 (p. 9.5.3) GS 95007-6-2:2017-04 (p. 9.5.3) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"范围","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"5 kV do 10 kV A.C.","range":"(50 Hz)"},{"name":"0,5 kV do 6 kV D.C. Withstand voltage after environmental testing","range":"(1 minute)"},{"name":"Range: 0,5 kV to 5 kV A.C.","range":"(50 Hz, 60 Hz)"},{"name":"5 kV do 10 kV A.C.","range":"(50 Hz)"}],"search_zh":"电缆 范围 ISO 19642-2:2019-01 (p. 5.2.4; 6.2.2) | ISO 19642-2:2023 (p. 5.3.4; 6.3.2) | ISO 19642-3:2019-01 (p. 5.3.4) | ISO 19642-4:2019-01 (p. 5.3.4) | ISO 19642-5:2019-01 (p. 5.3.4) | ISO 19642-6:2019-01 (p. 5.3.4) | ISO 19642-7:2019-01 (p. 6.3.2) | ISO 19642-8:2019-01 (p. 6.3.2) | ISO 19642-9:2019-01 (p. 6.3.2) | ISO 19642-10:2019-01 (p. 6.3.2) | ISO 14572:2011-10 (p. 5.5) LV 112-1:2013-04 (p. 9.5.3) LV 112-1:2014-04 (p. 9.5.3) LV 112-2:2007-11 (p. 8.6) LV 112-2:2013-04 (p. 9.5.3) LV 122:2015-05 (p. 11.4.4) LV 122:2016-02 (p. 11.5.4) LV 216-1:2015-07 (p. 9.5.3) LV 216-2:2017-02 (p. 9.5.3) VW 60306-1:2018-09-01 (p. 9.5.3) VW 60306-1:2021-10 (p. 9.6.3) VW 60306-2:2013-04 (p. 9.5.3) VW 60306-2:2021-11 (p. 9.6.3) VW 60306-4:2021-12 (p. 9.6.3) VW 75209-1:2015-01 (p. 9.5.3) VW 75209-1:2021-12 (p. 9.6.2) VW 75209-2:2015-01 (p. 9.5.3) VW 75209-2:2021-12 (p. 9.6.2) VW 75210-1:2023-06 (p. 9.6.3) VW 75210-1:2024-08 (p. 9.6.3) VW 75210-2:2023-06 (p. 9.6.3) MBN LV 112-1:2016-03 (p. 9.5.3) MBN 50112-1:2023-06 (p. 12.5.3) MBN LV 112-2:2012-01 (p. 8.6) MBN 50112-2: 2023-05 (p. 12.6) MBN 50216-1:2023-07 (p. 12.6.3) MBN LV 122:2017-06 (p. 11.5.4) MBN 50122:2023-07 (p. 13.5.4) MBN 50212-1:2023-04 (p. 12.6.3) MBN LV 216-2:2017-07 (p. 9.5.3) MBN 50112-4:2024-06 (p. 12.5.3) GS 95007-1-1:2013-05 (p. 9.5.3) GS 95007-1-2:2013-05 (p. 9.5.3) GS 95007-1-5:2015-07 (p. 11.4.4) GS 95007-6-1:2016-03 (p. 9.5.3) GS 95007-6-2:2017-04 (p. 9.5.3) Scope of accreditation No. AB 1776","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259eca","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Rezystywność izolacji / powłoki","methodology_en":"Resistivity of the insulation / sheath","parameters":[{"name":"Napięcie","range":"(1 - 1000) V D.C."},{"name":"Rezystancja","range":"2 kΩ - 1000 GΩ"},{"name":"Temperatura","range":"do 90°C"},{"name":"Insulation volume resistivity Range:"},{"name":"Voltage","range":"(1 V - 1000) V DC"}],"parameters_en":[{"name":"Voltage","range":"(1 - 1000) V D.C."},{"name":"Resistance","range":"2 kΩ - 1000 GΩ"},{"name":"Temperature","range":"do 90°C"},{"name":"Insulation volume resistivity Range:"},{"name":"Voltage","range":"(1 V - 1000) V DC"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystywność izolacji / powłoki\nZakres:\nNapięcie (1 - 1000) V D.C.\nRezystancja 2 kΩ - 1000 GΩ\nTemperatura do 90°C\nInsulation volume resistivity Range:\nVoltage (1 V - 1000) V DC","reference":"ISO 19642-2:2019-01 (p. 5.2.6) | ISO 19642-2:2023 (p. 5.3.6) | ISO 19642-3:2019-01 (p. 5.3.6) | ISO 19642-4:2019-01 (p. 5.3.6) | ISO 19642-5:2019-01 (p. 5.3.6) | ISO 19642-6:2019-01 (p. 5.3.6) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.7) | ISO 6722-2:2013-12-01 (p. 5.7) LV 112-1:2013-04 (p. 9.5.1) LV 112-1:2014-04 (p. 9.5.1) LV 112-2:2007-11 (p. 8.6) LV 112-2:2013-04 (p. 9.5.1) LV 212-2:2015-01 (p. 9.5.1) LV 216-1:2015-07 (p. 9.5.1) LV 216-2:2017-02 (p. 9.5.1) VW 60306-1:2018-09-01 (p. 9.5.1) VW 60306-1:2021-10 (p. 9.6.1) VW 60306-2:2013-04 (p. 9.5.1) VW 60306-2:2021-11 (p. 9.6.1) VW 60306-4:2021-12 (p. 9.6.1) VW 75205:2019-11 (p. 11.4.2) VW 75205:2023-05 (p. 11.4.2) VW 75205:2024-04 (p. 11.5.2) VW 75209-1:2015-01 (p. 9.5.1) VW 75209-2:2015-01 (p. 9.5.1) VW 75209-2:2021-12 (p. 9.6) VW 75210-1:2023-06 (p. 9.6.1) VW 75210-1:2024-08 (p. 9.6.1) VW 75210-2:2023-06 (p. 9.6.1) MBN LV 112-1:2016-03 (p. 9.5.1) MBN 50112-1:2023-06 (p. 12.5.1) MBN LV 112-2:2012-01 (p. 8.6) MBN 50112-2: 2023-05 (p. 12.6) MBN 50216-1:2023-07 (p. 12.6.1) MBN LV 216-2:2017-07 (p. 9.5.1) MBN 50112-4:2024-06 (p. 12.5.1) GS 95007-1-1:2013-05 (p. 9.5.1) GS 95007-1-2:2013-05 (p. 9.5.1) GS 95007-3-2:2015-09 (p. 9.5.1) GS 95007-6-1:2016-03 (p. 9.5.1) GS 95007-6-2:2017-04 (p. 9.5.1) Scope of accreditation No. AB 1776","norm_bases":["ISO 19642-2:2019-01 (p. 5.2.6)","ISO 19642-2:2023 (p. 5.3.6)","ISO 19642-3:2019-01 (p. 5.3.6)","ISO 19642-4:2019-01 (p. 5.3.6)","ISO 19642-5:2019-01 (p. 5.3.6)","ISO 19642-6:2019-01 (p. 5.3.6)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.7)","ISO 6722-2:2013-12-01 (p. 5.7) LV 112-1:2013-04 (p. 9.5.1) LV 112-1:2014-04 (p. 9.5.1) LV 112-2:2007-11 (p. 8.6) LV 112-2:2013-04 (p. 9.5.1) LV 212-2:2015-01 (p. 9.5.1) LV 216-1:2015-07 (p. 9.5.1) LV 216-2:2017-02 (p. 9.5.1) VW 60306-1:2018-09-01 (p. 9.5.1) VW 60306-1:2021-10 (p. 9.6.1) VW 60306-2:2013-04 (p. 9.5.1) VW 60306-2:2021-11 (p. 9.6.1) VW 60306-4:2021-12 (p. 9.6.1) VW 75205:2019-11 (p. 11.4.2) VW 75205:2023-05 (p. 11.4.2) VW 75205:2024-04 (p. 11.5.2) VW 75209-1:2015-01 (p. 9.5.1) VW 75209-2:2015-01 (p. 9.5.1) VW 75209-2:2021-12 (p. 9.6) VW 75210-1:2023-06 (p. 9.6.1) VW 75210-1:2024-08 (p. 9.6.1) VW 75210-2:2023-06 (p. 9.6.1) MBN LV 112-1:2016-03 (p. 9.5.1) MBN 50112-1:2023-06 (p. 12.5.1) MBN LV 112-2:2012-01 (p. 8.6) MBN 50112-2: 2023-05 (p. 12.6) MBN 50216-1:2023-07 (p. 12.6.1) MBN LV 216-2:2017-07 (p. 9.5.1) MBN 50112-4:2024-06 (p. 12.5.1) GS 95007-1-1:2013-05 (p. 9.5.1) GS 95007-1-2:2013-05 (p. 9.5.1) GS 95007-3-2:2015-09 (p. 9.5.1) GS 95007-6-1:2016-03 (p. 9.5.1) GS 95007-6-2:2017-04 (p. 9.5.1) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Rezystywność izolacji / powłoki\nZakres:\nNapięcie (1 - 1000) V D.C.\nRezystancja 2 kΩ - 1000 GΩ\nTemperatura do 90°C\nInsulation volume resistivity Range:\nVoltage (1 V - 1000) V DC ISO 19642-2:2019-01 (p. 5.2.6) | ISO 19642-2:2023 (p. 5.3.6) | ISO 19642-3:2019-01 (p. 5.3.6) | ISO 19642-4:2019-01 (p. 5.3.6) | ISO 19642-5:2019-01 (p. 5.3.6) | ISO 19642-6:2019-01 (p. 5.3.6) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.7) | ISO 6722-2:2013-12-01 (p. 5.7) LV 112-1:2013-04 (p. 9.5.1) LV 112-1:2014-04 (p. 9.5.1) LV 112-2:2007-11 (p. 8.6) LV 112-2:2013-04 (p. 9.5.1) LV 212-2:2015-01 (p. 9.5.1) LV 216-1:2015-07 (p. 9.5.1) LV 216-2:2017-02 (p. 9.5.1) VW 60306-1:2018-09-01 (p. 9.5.1) VW 60306-1:2021-10 (p. 9.6.1) VW 60306-2:2013-04 (p. 9.5.1) VW 60306-2:2021-11 (p. 9.6.1) VW 60306-4:2021-12 (p. 9.6.1) VW 75205:2019-11 (p. 11.4.2) VW 75205:2023-05 (p. 11.4.2) VW 75205:2024-04 (p. 11.5.2) VW 75209-1:2015-01 (p. 9.5.1) VW 75209-2:2015-01 (p. 9.5.1) VW 75209-2:2021-12 (p. 9.6) VW 75210-1:2023-06 (p. 9.6.1) VW 75210-1:2024-08 (p. 9.6.1) VW 75210-2:2023-06 (p. 9.6.1) MBN LV 112-1:2016-03 (p. 9.5.1) MBN 50112-1:2023-06 (p. 12.5.1) MBN LV 112-2:2012-01 (p. 8.6) MBN 50112-2: 2023-05 (p. 12.6) MBN 50216-1:2023-07 (p. 12.6.1) MBN LV 216-2:2017-07 (p. 9.5.1) MBN 50112-4:2024-06 (p. 12.5.1) GS 95007-1-1:2013-05 (p. 9.5.1) GS 95007-1-2:2013-05 (p. 9.5.1) GS 95007-3-2:2015-09 (p. 9.5.1) GS 95007-6-1:2016-03 (p. 9.5.1) GS 95007-6-2:2017-04 (p. 9.5.1) Scope of accreditation No. AB 1776 Kable, Cables Rezystywnosc izolacji / powloki\nZakres:\nNapiecie (1 - 1000) V D.C.\nRezystancja 2 kΩ - 1000 GΩ\nTemperatura do 90°C\nInsulation volume resistivity Range:\nVoltage (1 V - 1000) V DC ISO 19642-2:2019-01 (p. 5.2.6) | ISO 19642-2:2023 (p. 5.3.6) | ISO 19642-3:2019-01 (p. 5.3.6) | ISO 19642-4:2019-01 (p. 5.3.6) | ISO 19642-5:2019-01 (p. 5.3.6) | ISO 19642-6:2019-01 (p. 5.3.6) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.7) | ISO 6722-2:2013-12-01 (p. 5.7) LV 112-1:2013-04 (p. 9.5.1) LV 112-1:2014-04 (p. 9.5.1) LV 112-2:2007-11 (p. 8.6) LV 112-2:2013-04 (p. 9.5.1) LV 212-2:2015-01 (p. 9.5.1) LV 216-1:2015-07 (p. 9.5.1) LV 216-2:2017-02 (p. 9.5.1) VW 60306-1:2018-09-01 (p. 9.5.1) VW 60306-1:2021-10 (p. 9.6.1) VW 60306-2:2013-04 (p. 9.5.1) VW 60306-2:2021-11 (p. 9.6.1) VW 60306-4:2021-12 (p. 9.6.1) VW 75205:2019-11 (p. 11.4.2) VW 75205:2023-05 (p. 11.4.2) VW 75205:2024-04 (p. 11.5.2) VW 75209-1:2015-01 (p. 9.5.1) VW 75209-2:2015-01 (p. 9.5.1) VW 75209-2:2021-12 (p. 9.6) VW 75210-1:2023-06 (p. 9.6.1) VW 75210-1:2024-08 (p. 9.6.1) VW 75210-2:2023-06 (p. 9.6.1) MBN LV 112-1:2016-03 (p. 9.5.1) MBN 50112-1:2023-06 (p. 12.5.1) MBN LV 112-2:2012-01 (p. 8.6) MBN 50112-2: 2023-05 (p. 12.6) MBN 50216-1:2023-07 (p. 12.6.1) MBN LV 216-2:2017-07 (p. 9.5.1) MBN 50112-4:2024-06 (p. 12.5.1) GS 95007-1-1:2013-05 (p. 9.5.1) GS 95007-1-2:2013-05 (p. 9.5.1) GS 95007-3-2:2015-09 (p. 9.5.1) GS 95007-6-1:2016-03 (p. 9.5.1) GS 95007-6-2:2017-04 (p. 9.5.1) Scope of accreditation No. AB 1776","categories":["construction"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Resistivity of the insulation / sheath Voltage Resistance Temperature Insulation volume resistivity Range: Voltage ISO 19642-2:2019-01 (p. 5.2.6) | ISO 19642-2:2023 (p. 5.3.6) | ISO 19642-3:2019-01 (p. 5.3.6) | ISO 19642-4:2019-01 (p. 5.3.6) | ISO 19642-5:2019-01 (p. 5.3.6) | ISO 19642-6:2019-01 (p. 5.3.6) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.7) | ISO 6722-2:2013-12-01 (p. 5.7) LV 112-1:2013-04 (p. 9.5.1) LV 112-1:2014-04 (p. 9.5.1) LV 112-2:2007-11 (p. 8.6) LV 112-2:2013-04 (p. 9.5.1) LV 212-2:2015-01 (p. 9.5.1) LV 216-1:2015-07 (p. 9.5.1) LV 216-2:2017-02 (p. 9.5.1) VW 60306-1:2018-09-01 (p. 9.5.1) VW 60306-1:2021-10 (p. 9.6.1) VW 60306-2:2013-04 (p. 9.5.1) VW 60306-2:2021-11 (p. 9.6.1) VW 60306-4:2021-12 (p. 9.6.1) VW 75205:2019-11 (p. 11.4.2) VW 75205:2023-05 (p. 11.4.2) VW 75205:2024-04 (p. 11.5.2) VW 75209-1:2015-01 (p. 9.5.1) VW 75209-2:2015-01 (p. 9.5.1) VW 75209-2:2021-12 (p. 9.6) VW 75210-1:2023-06 (p. 9.6.1) VW 75210-1:2024-08 (p. 9.6.1) VW 75210-2:2023-06 (p. 9.6.1) MBN LV 112-1:2016-03 (p. 9.5.1) MBN 50112-1:2023-06 (p. 12.5.1) MBN LV 112-2:2012-01 (p. 8.6) MBN 50112-2: 2023-05 (p. 12.6) MBN 50216-1:2023-07 (p. 12.6.1) MBN LV 216-2:2017-07 (p. 9.5.1) MBN 50112-4:2024-06 (p. 12.5.1) GS 95007-1-1:2013-05 (p. 9.5.1) GS 95007-1-2:2013-05 (p. 9.5.1) GS 95007-3-2:2015-09 (p. 9.5.1) GS 95007-6-1:2016-03 (p. 9.5.1) GS 95007-6-2:2017-04 (p. 9.5.1) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"电压","range":"(1 - 1000) V D.C."},{"name":"电阻","range":"2 kΩ - 1000 GΩ"},{"name":"温度","range":"do 90°C"},{"name":"Insulation volume resistivity Range:"},{"name":"Voltage","range":"(1 V - 1000) V DC"}],"search_zh":"电缆 电压 电阻 温度 ISO 19642-2:2019-01 (p. 5.2.6) | ISO 19642-2:2023 (p. 5.3.6) | ISO 19642-3:2019-01 (p. 5.3.6) | ISO 19642-4:2019-01 (p. 5.3.6) | ISO 19642-5:2019-01 (p. 5.3.6) | ISO 19642-6:2019-01 (p. 5.3.6) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.7) | ISO 6722-2:2013-12-01 (p. 5.7) LV 112-1:2013-04 (p. 9.5.1) LV 112-1:2014-04 (p. 9.5.1) LV 112-2:2007-11 (p. 8.6) LV 112-2:2013-04 (p. 9.5.1) LV 212-2:2015-01 (p. 9.5.1) LV 216-1:2015-07 (p. 9.5.1) LV 216-2:2017-02 (p. 9.5.1) VW 60306-1:2018-09-01 (p. 9.5.1) VW 60306-1:2021-10 (p. 9.6.1) VW 60306-2:2013-04 (p. 9.5.1) VW 60306-2:2021-11 (p. 9.6.1) VW 60306-4:2021-12 (p. 9.6.1) VW 75205:2019-11 (p. 11.4.2) VW 75205:2023-05 (p. 11.4.2) VW 75205:2024-04 (p. 11.5.2) VW 75209-1:2015-01 (p. 9.5.1) VW 75209-2:2015-01 (p. 9.5.1) VW 75209-2:2021-12 (p. 9.6) VW 75210-1:2023-06 (p. 9.6.1) VW 75210-1:2024-08 (p. 9.6.1) VW 75210-2:2023-06 (p. 9.6.1) MBN LV 112-1:2016-03 (p. 9.5.1) MBN 50112-1:2023-06 (p. 12.5.1) MBN LV 112-2:2012-01 (p. 8.6) MBN 50112-2: 2023-05 (p. 12.6) MBN 50216-1:2023-07 (p. 12.6.1) MBN LV 216-2:2017-07 (p. 9.5.1) MBN 50112-4:2024-06 (p. 12.5.1) GS 95007-1-1:2013-05 (p. 9.5.1) GS 95007-1-2:2013-05 (p. 9.5.1) GS 95007-3-2:2015-09 (p. 9.5.1) GS 95007-6-1:2016-03 (p. 9.5.1) GS 95007-6-2:2017-04 (p. 9.5.1) Scope of accreditation No. AB 1776","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ecb","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Ściągalność izolacji / powłoki / ekranu kabla","methodology_en":"Strippability of cable insulation / sheath / screen","parameters":[{"name":"Maszyna wytrzymałościowa","range":"do 20 kN"},{"name":"Strip force Range:"}],"parameters_en":[{"name":"Testing machine","range":"do 20 kN"},{"name":"Strip force Range:"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ściągalność izolacji / powłoki / ekranu kabla\nZakres:\nMaszyna wytrzymałościowa do 20 kN\nStrip force Range:","reference":"ISO 19642-2:2019-01 (p. 5.3.1, 6.3.1) | ISO 19642-2:2023 (p. 5.4.1; 6.4.1; 6.4.7) | ISO 19642-3:2019-01 (p. 5.4.1) | ISO 19642-4:2019-01 (p. 5.4.1) | ISO 19642-5:2019-01 (p. 5.4.1) | ISO 19642-6:2019-01 (p. 5.4.1) | ISO 19642-7:2019-01 (p. 6.4.1) | ISO 19642-8:2019-01 (p. 6.4.1) | ISO 19642-9:2019-01 (p. 6.4.1) | ISO 19642-10:2019-01 (p. 6.4.1) | ISO 6722-1:2011-10-15 ; corr.1:2012-09-15 (p. 5.9) | ISO 6722-2:2013-12-01 (p. 5.9) | ISO 14572:2011-10 (p. 5.8) LV 112-1:2013-04 (p. 9.3.1) LV 112-1:2014-04 (p. 9.4) LV 112-2:2007-11 (p. 8.4.1) LV 112-2:2013-04 (p. 9.3.1) LV 212-1:2015-01 (p. 9.3.1) LV 212-2:2015-01 (p. 9.3.1) LV 216-1:2015-07 (p. 9.3.1) LV 216-2:2017-02 (p. 9.3.1) VW 60306-1:2018-09-01 (p. 9.3.1) VW 60306-1:2021-10 (p. 9.4.1) VW 60306-2:2013-04 (p. 9.3.1) VW 60306-2:2021-11 (p. 9.4.1) VW 60306-4:2021-12 (p. 9.4.1) VW 75209-1:2015-01 (p. 9.3.1) VW 75209-1:2021-12 (p. 9.4.1) VW 75209-2:2015-01 (p. 9.3.1) VW 75209-2:2021-12 (p. 9.6.2) VW 75210-1:2023-06 (p. 9.4.1) VW 75210-1:2024-08 (p. 9.4.1) VW 75210-2:2023-06 (p. 9.4.1) MBN LV 112-1:2016-03 (p. 9.3.1) MBN 50112-1:2023-06 (p. 12.3.2) MBN LV 112-2:2012-01 (p. 8.4.1) MBN 50112-2:2023-05 (p. 12.4.1) MBN 50216-1:2023-07 (p. 12.4.2) MBN LV 212-1:2017-08 (p. 9.3.1) MBN 50212-1:2023-04 (p. 12.4.1) MBN LV 216-2:2017-07 (p. 9.3.1) MBN 50112-4:2024-06 (p. 12.3.2) GS 95007-1-1:2013-05 (p. 9.3.1) GS 95007-1-2:2013-05 (p. 9.3.1) GS 95007-3-1:2015-08 (p. 9.3.1) GS 95007-3-2:2015-09 (p. 9.3.1) GS 95007-6-1:2016-03 (p. 9.3.1) GS 95007-6-2:2017-04 (p. 9.3.1) Scope of accreditation No. AB 1776","norm_bases":["ISO 19642-2:2019-01 (p. 5.3.1, 6.3.1)","ISO 19642-2:2023 (p. 5.4.1; 6.4.1; 6.4.7)","ISO 19642-3:2019-01 (p. 5.4.1)","ISO 19642-4:2019-01 (p. 5.4.1)","ISO 19642-5:2019-01 (p. 5.4.1)","ISO 19642-6:2019-01 (p. 5.4.1)","ISO 19642-7:2019-01 (p. 6.4.1)","ISO 19642-8:2019-01 (p. 6.4.1)","ISO 19642-9:2019-01 (p. 6.4.1)","ISO 19642-10:2019-01 (p. 6.4.1)","ISO 6722-1:2011-10-15 ; corr.1:2012-09-15 (p. 5.9)","ISO 6722-2:2013-12-01 (p. 5.9)","ISO 14572:2011-10 (p. 5.8) LV 112-1:2013-04 (p. 9.3.1) LV 112-1:2014-04 (p. 9.4) LV 112-2:2007-11 (p. 8.4.1) LV 112-2:2013-04 (p. 9.3.1) LV 212-1:2015-01 (p. 9.3.1) LV 212-2:2015-01 (p. 9.3.1) LV 216-1:2015-07 (p. 9.3.1) LV 216-2:2017-02 (p. 9.3.1) VW 60306-1:2018-09-01 (p. 9.3.1) VW 60306-1:2021-10 (p. 9.4.1) VW 60306-2:2013-04 (p. 9.3.1) VW 60306-2:2021-11 (p. 9.4.1) VW 60306-4:2021-12 (p. 9.4.1) VW 75209-1:2015-01 (p. 9.3.1) VW 75209-1:2021-12 (p. 9.4.1) VW 75209-2:2015-01 (p. 9.3.1) VW 75209-2:2021-12 (p. 9.6.2) VW 75210-1:2023-06 (p. 9.4.1) VW 75210-1:2024-08 (p. 9.4.1) VW 75210-2:2023-06 (p. 9.4.1) MBN LV 112-1:2016-03 (p. 9.3.1) MBN 50112-1:2023-06 (p. 12.3.2) MBN LV 112-2:2012-01 (p. 8.4.1) MBN 50112-2:2023-05 (p. 12.4.1) MBN 50216-1:2023-07 (p. 12.4.2) MBN LV 212-1:2017-08 (p. 9.3.1) MBN 50212-1:2023-04 (p. 12.4.1) MBN LV 216-2:2017-07 (p. 9.3.1) MBN 50112-4:2024-06 (p. 12.3.2) GS 95007-1-1:2013-05 (p. 9.3.1) GS 95007-1-2:2013-05 (p. 9.3.1) GS 95007-3-1:2015-08 (p. 9.3.1) GS 95007-3-2:2015-09 (p. 9.3.1) GS 95007-6-1:2016-03 (p. 9.3.1) GS 95007-6-2:2017-04 (p. 9.3.1) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Ściągalność izolacji / powłoki / ekranu kabla\nZakres:\nMaszyna wytrzymałościowa do 20 kN\nStrip force Range: ISO 19642-2:2019-01 (p. 5.3.1, 6.3.1) | ISO 19642-2:2023 (p. 5.4.1; 6.4.1; 6.4.7) | ISO 19642-3:2019-01 (p. 5.4.1) | ISO 19642-4:2019-01 (p. 5.4.1) | ISO 19642-5:2019-01 (p. 5.4.1) | ISO 19642-6:2019-01 (p. 5.4.1) | ISO 19642-7:2019-01 (p. 6.4.1) | ISO 19642-8:2019-01 (p. 6.4.1) | ISO 19642-9:2019-01 (p. 6.4.1) | ISO 19642-10:2019-01 (p. 6.4.1) | ISO 6722-1:2011-10-15 ; corr.1:2012-09-15 (p. 5.9) | ISO 6722-2:2013-12-01 (p. 5.9) | ISO 14572:2011-10 (p. 5.8) LV 112-1:2013-04 (p. 9.3.1) LV 112-1:2014-04 (p. 9.4) LV 112-2:2007-11 (p. 8.4.1) LV 112-2:2013-04 (p. 9.3.1) LV 212-1:2015-01 (p. 9.3.1) LV 212-2:2015-01 (p. 9.3.1) LV 216-1:2015-07 (p. 9.3.1) LV 216-2:2017-02 (p. 9.3.1) VW 60306-1:2018-09-01 (p. 9.3.1) VW 60306-1:2021-10 (p. 9.4.1) VW 60306-2:2013-04 (p. 9.3.1) VW 60306-2:2021-11 (p. 9.4.1) VW 60306-4:2021-12 (p. 9.4.1) VW 75209-1:2015-01 (p. 9.3.1) VW 75209-1:2021-12 (p. 9.4.1) VW 75209-2:2015-01 (p. 9.3.1) VW 75209-2:2021-12 (p. 9.6.2) VW 75210-1:2023-06 (p. 9.4.1) VW 75210-1:2024-08 (p. 9.4.1) VW 75210-2:2023-06 (p. 9.4.1) MBN LV 112-1:2016-03 (p. 9.3.1) MBN 50112-1:2023-06 (p. 12.3.2) MBN LV 112-2:2012-01 (p. 8.4.1) MBN 50112-2:2023-05 (p. 12.4.1) MBN 50216-1:2023-07 (p. 12.4.2) MBN LV 212-1:2017-08 (p. 9.3.1) MBN 50212-1:2023-04 (p. 12.4.1) MBN LV 216-2:2017-07 (p. 9.3.1) MBN 50112-4:2024-06 (p. 12.3.2) GS 95007-1-1:2013-05 (p. 9.3.1) GS 95007-1-2:2013-05 (p. 9.3.1) GS 95007-3-1:2015-08 (p. 9.3.1) GS 95007-3-2:2015-09 (p. 9.3.1) GS 95007-6-1:2016-03 (p. 9.3.1) GS 95007-6-2:2017-04 (p. 9.3.1) Scope of accreditation No. AB 1776 Kable, Cables Sciagalnosc izolacji / powloki / ekranu kabla\nZakres:\nMaszyna wytrzymalosciowa do 20 kN\nStrip force Range: ISO 19642-2:2019-01 (p. 5.3.1, 6.3.1) | ISO 19642-2:2023 (p. 5.4.1; 6.4.1; 6.4.7) | ISO 19642-3:2019-01 (p. 5.4.1) | ISO 19642-4:2019-01 (p. 5.4.1) | ISO 19642-5:2019-01 (p. 5.4.1) | ISO 19642-6:2019-01 (p. 5.4.1) | ISO 19642-7:2019-01 (p. 6.4.1) | ISO 19642-8:2019-01 (p. 6.4.1) | ISO 19642-9:2019-01 (p. 6.4.1) | ISO 19642-10:2019-01 (p. 6.4.1) | ISO 6722-1:2011-10-15 ; corr.1:2012-09-15 (p. 5.9) | ISO 6722-2:2013-12-01 (p. 5.9) | ISO 14572:2011-10 (p. 5.8) LV 112-1:2013-04 (p. 9.3.1) LV 112-1:2014-04 (p. 9.4) LV 112-2:2007-11 (p. 8.4.1) LV 112-2:2013-04 (p. 9.3.1) LV 212-1:2015-01 (p. 9.3.1) LV 212-2:2015-01 (p. 9.3.1) LV 216-1:2015-07 (p. 9.3.1) LV 216-2:2017-02 (p. 9.3.1) VW 60306-1:2018-09-01 (p. 9.3.1) VW 60306-1:2021-10 (p. 9.4.1) VW 60306-2:2013-04 (p. 9.3.1) VW 60306-2:2021-11 (p. 9.4.1) VW 60306-4:2021-12 (p. 9.4.1) VW 75209-1:2015-01 (p. 9.3.1) VW 75209-1:2021-12 (p. 9.4.1) VW 75209-2:2015-01 (p. 9.3.1) VW 75209-2:2021-12 (p. 9.6.2) VW 75210-1:2023-06 (p. 9.4.1) VW 75210-1:2024-08 (p. 9.4.1) VW 75210-2:2023-06 (p. 9.4.1) MBN LV 112-1:2016-03 (p. 9.3.1) MBN 50112-1:2023-06 (p. 12.3.2) MBN LV 112-2:2012-01 (p. 8.4.1) MBN 50112-2:2023-05 (p. 12.4.1) MBN 50216-1:2023-07 (p. 12.4.2) MBN LV 212-1:2017-08 (p. 9.3.1) MBN 50212-1:2023-04 (p. 12.4.1) MBN LV 216-2:2017-07 (p. 9.3.1) MBN 50112-4:2024-06 (p. 12.3.2) GS 95007-1-1:2013-05 (p. 9.3.1) GS 95007-1-2:2013-05 (p. 9.3.1) GS 95007-3-1:2015-08 (p. 9.3.1) GS 95007-3-2:2015-09 (p. 9.3.1) GS 95007-6-1:2016-03 (p. 9.3.1) GS 95007-6-2:2017-04 (p. 9.3.1) Scope of accreditation No. AB 1776","categories":["construction"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Strippability of cable insulation / sheath / screen Testing machine Strip force Range: ISO 19642-2:2019-01 (p. 5.3.1, 6.3.1) | ISO 19642-2:2023 (p. 5.4.1; 6.4.1; 6.4.7) | ISO 19642-3:2019-01 (p. 5.4.1) | ISO 19642-4:2019-01 (p. 5.4.1) | ISO 19642-5:2019-01 (p. 5.4.1) | ISO 19642-6:2019-01 (p. 5.4.1) | ISO 19642-7:2019-01 (p. 6.4.1) | ISO 19642-8:2019-01 (p. 6.4.1) | ISO 19642-9:2019-01 (p. 6.4.1) | ISO 19642-10:2019-01 (p. 6.4.1) | ISO 6722-1:2011-10-15 ; corr.1:2012-09-15 (p. 5.9) | ISO 6722-2:2013-12-01 (p. 5.9) | ISO 14572:2011-10 (p. 5.8) LV 112-1:2013-04 (p. 9.3.1) LV 112-1:2014-04 (p. 9.4) LV 112-2:2007-11 (p. 8.4.1) LV 112-2:2013-04 (p. 9.3.1) LV 212-1:2015-01 (p. 9.3.1) LV 212-2:2015-01 (p. 9.3.1) LV 216-1:2015-07 (p. 9.3.1) LV 216-2:2017-02 (p. 9.3.1) VW 60306-1:2018-09-01 (p. 9.3.1) VW 60306-1:2021-10 (p. 9.4.1) VW 60306-2:2013-04 (p. 9.3.1) VW 60306-2:2021-11 (p. 9.4.1) VW 60306-4:2021-12 (p. 9.4.1) VW 75209-1:2015-01 (p. 9.3.1) VW 75209-1:2021-12 (p. 9.4.1) VW 75209-2:2015-01 (p. 9.3.1) VW 75209-2:2021-12 (p. 9.6.2) VW 75210-1:2023-06 (p. 9.4.1) VW 75210-1:2024-08 (p. 9.4.1) VW 75210-2:2023-06 (p. 9.4.1) MBN LV 112-1:2016-03 (p. 9.3.1) MBN 50112-1:2023-06 (p. 12.3.2) MBN LV 112-2:2012-01 (p. 8.4.1) MBN 50112-2:2023-05 (p. 12.4.1) MBN 50216-1:2023-07 (p. 12.4.2) MBN LV 212-1:2017-08 (p. 9.3.1) MBN 50212-1:2023-04 (p. 12.4.1) MBN LV 216-2:2017-07 (p. 9.3.1) MBN 50112-4:2024-06 (p. 12.3.2) GS 95007-1-1:2013-05 (p. 9.3.1) GS 95007-1-2:2013-05 (p. 9.3.1) GS 95007-3-1:2015-08 (p. 9.3.1) GS 95007-3-2:2015-09 (p. 9.3.1) GS 95007-6-1:2016-03 (p. 9.3.1) GS 95007-6-2:2017-04 (p. 9.3.1) Scope of accreditation No. AB 1776","search_zh":"电缆 材料试验机 ISO 19642-2:2019-01 (p. 5.3.1, 6.3.1) | ISO 19642-2:2023 (p. 5.4.1; 6.4.1; 6.4.7) | ISO 19642-3:2019-01 (p. 5.4.1) | ISO 19642-4:2019-01 (p. 5.4.1) | ISO 19642-5:2019-01 (p. 5.4.1) | ISO 19642-6:2019-01 (p. 5.4.1) | ISO 19642-7:2019-01 (p. 6.4.1) | ISO 19642-8:2019-01 (p. 6.4.1) | ISO 19642-9:2019-01 (p. 6.4.1) | ISO 19642-10:2019-01 (p. 6.4.1) | ISO 6722-1:2011-10-15 ; corr.1:2012-09-15 (p. 5.9) | ISO 6722-2:2013-12-01 (p. 5.9) | ISO 14572:2011-10 (p. 5.8) LV 112-1:2013-04 (p. 9.3.1) LV 112-1:2014-04 (p. 9.4) LV 112-2:2007-11 (p. 8.4.1) LV 112-2:2013-04 (p. 9.3.1) LV 212-1:2015-01 (p. 9.3.1) LV 212-2:2015-01 (p. 9.3.1) LV 216-1:2015-07 (p. 9.3.1) LV 216-2:2017-02 (p. 9.3.1) VW 60306-1:2018-09-01 (p. 9.3.1) VW 60306-1:2021-10 (p. 9.4.1) VW 60306-2:2013-04 (p. 9.3.1) VW 60306-2:2021-11 (p. 9.4.1) VW 60306-4:2021-12 (p. 9.4.1) VW 75209-1:2015-01 (p. 9.3.1) VW 75209-1:2021-12 (p. 9.4.1) VW 75209-2:2015-01 (p. 9.3.1) VW 75209-2:2021-12 (p. 9.6.2) VW 75210-1:2023-06 (p. 9.4.1) VW 75210-1:2024-08 (p. 9.4.1) VW 75210-2:2023-06 (p. 9.4.1) MBN LV 112-1:2016-03 (p. 9.3.1) MBN 50112-1:2023-06 (p. 12.3.2) MBN LV 112-2:2012-01 (p. 8.4.1) MBN 50112-2:2023-05 (p. 12.4.1) MBN 50216-1:2023-07 (p. 12.4.2) MBN LV 212-1:2017-08 (p. 9.3.1) MBN 50212-1:2023-04 (p. 12.4.1) MBN LV 216-2:2017-07 (p. 9.3.1) MBN 50112-4:2024-06 (p. 12.3.2) GS 95007-1-1:2013-05 (p. 9.3.1) GS 95007-1-2:2013-05 (p. 9.3.1) GS 95007-3-1:2015-08 (p. 9.3.1) GS 95007-3-2:2015-09 (p. 9.3.1) GS 95007-6-1:2016-03 (p. 9.3.1) GS 95007-6-2:2017-04 (p. 9.3.1) Scope of accreditation No. AB 1776","test_object_zh":"电缆","parameters_zh":[{"name":"材料试验机","range":"do 20 kN"},{"name":"Strip force Range:"}]},{"_id":"6a5dc9a9f1c10c8ce8259ecc","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Odporność izolacji / powłoki kabla na przetarcie","methodology_en":"Resistance of cable insulation / sheath to abrasion","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność izolacji / powłoki kabla na przetarcie","reference":"ISO 19642-2 2019-01 (p. 5.3.2.5) | ISO 19642-2:2023 (p. 5.4.2.5; 6.4.8.6) | ISO 19642-3:2019-01 (p. 5.4.2.3) | ISO 19642-4:2019-01 (p. 5.4.2.3) | ISO 19642-5:2019-01 (p. 5.4.2.3) | ISO 19642-6:2019-01 (p. 5.4.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.12.4.2) | ISO 6722-2:2013-12-01 (p. 5.12) LV 112-1:2013-04 (p. 9.3.2) LV 112-1:2014-04 (p. 9.3.2) LV 112-2:2007-11 (p. 8.4.2) LV 112-2:2013-04 (p. 9.3.2) LV 212-1:2015-01 (p. 9.3.2) LV 216-1:2015-07 (p. 9.3.2) LV 212-2:2015-01 (p. 9.3.2) LV 216-2:2017-02 (p. 9.3.2) VW 60306-1:2018-09-01 (p. 9.3.2) VW 60306-1:2021-10 (p. 9.4.2) VW 60306-2:2013-04 (p. 9.3.2) VW 60306-2:2021-11 (p. 9.4.2) VW 60306-4:2021-12 (p. 9.4.2) VW 75209-1:2015-01 (p. 9.3.2) VW 75209-1:2021-12 (p. 9.4.2) VW 75209-2:2015-01 (p. 9.3.2) VW 75209-2:2021-12 (p. 9.4.1) VW 75210-1:2023-06 (p. 9.4.2) VW 75210-1:2024-08 (p. 9.4.2) VW 75210-2:2023-06 (p. 9.4.2) MBN LV 112-1:2016-03 (p. 9.3.2) MBN 50112-1:2023-06 (p. 12.3.3) MBN LV 112-2:2012-01 (p. 8.4.2) MBN 50112-2:2023-05 (p. 12.4.2) MBN 50216-1:2023-07 (p. 12.4.3) MBN LV 212-1:2017-08 (p. 9.3.2) MBN 50212-1:2023-04 (p. 12.4.2) MBN LV 216-2:2017-07 (p. 9.3.2) MBN 50112-4:2024-06 (p. 12.3.3) GS 95007-1-1:2013-05 (p. 9.3.2) GS 95007-1-2:2013-05 (p. 9.3.2) GS 95007-3-1:2015-08 (p. 9.3.2) GS 95007-3-2:2015-09 (p. 9.3.2) GS 95007-6-1:2016-03 (p. 9.3.2) GS 95007-6-2:2017-04 (p. 9.3.2)","norm_bases":["ISO 19642-2 2019-01 (p. 5.3.2.5)","ISO 19642-2:2023 (p. 5.4.2.5; 6.4.8.6)","ISO 19642-3:2019-01 (p. 5.4.2.3)","ISO 19642-4:2019-01 (p. 5.4.2.3)","ISO 19642-5:2019-01 (p. 5.4.2.3)","ISO 19642-6:2019-01 (p. 5.4.2.3)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.12.4.2)","ISO 6722-2:2013-12-01 (p. 5.12) LV 112-1:2013-04 (p. 9.3.2) LV 112-1:2014-04 (p. 9.3.2) LV 112-2:2007-11 (p. 8.4.2) LV 112-2:2013-04 (p. 9.3.2) LV 212-1:2015-01 (p. 9.3.2) LV 216-1:2015-07 (p. 9.3.2) LV 212-2:2015-01 (p. 9.3.2) LV 216-2:2017-02 (p. 9.3.2) VW 60306-1:2018-09-01 (p. 9.3.2) VW 60306-1:2021-10 (p. 9.4.2) VW 60306-2:2013-04 (p. 9.3.2) VW 60306-2:2021-11 (p. 9.4.2) VW 60306-4:2021-12 (p. 9.4.2) VW 75209-1:2015-01 (p. 9.3.2) VW 75209-1:2021-12 (p. 9.4.2) VW 75209-2:2015-01 (p. 9.3.2) VW 75209-2:2021-12 (p. 9.4.1) VW 75210-1:2023-06 (p. 9.4.2) VW 75210-1:2024-08 (p. 9.4.2) VW 75210-2:2023-06 (p. 9.4.2) MBN LV 112-1:2016-03 (p. 9.3.2) MBN 50112-1:2023-06 (p. 12.3.3) MBN LV 112-2:2012-01 (p. 8.4.2) MBN 50112-2:2023-05 (p. 12.4.2) MBN 50216-1:2023-07 (p. 12.4.3) MBN LV 212-1:2017-08 (p. 9.3.2) MBN 50212-1:2023-04 (p. 12.4.2) MBN LV 216-2:2017-07 (p. 9.3.2) MBN 50112-4:2024-06 (p. 12.3.3) GS 95007-1-1:2013-05 (p. 9.3.2) GS 95007-1-2:2013-05 (p. 9.3.2) GS 95007-3-1:2015-08 (p. 9.3.2) GS 95007-3-2:2015-09 (p. 9.3.2) GS 95007-6-1:2016-03 (p. 9.3.2) GS 95007-6-2:2017-04 (p. 9.3.2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Odporność izolacji / powłoki kabla na przetarcie ISO 19642-2 2019-01 (p. 5.3.2.5) | ISO 19642-2:2023 (p. 5.4.2.5; 6.4.8.6) | ISO 19642-3:2019-01 (p. 5.4.2.3) | ISO 19642-4:2019-01 (p. 5.4.2.3) | ISO 19642-5:2019-01 (p. 5.4.2.3) | ISO 19642-6:2019-01 (p. 5.4.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.12.4.2) | ISO 6722-2:2013-12-01 (p. 5.12) LV 112-1:2013-04 (p. 9.3.2) LV 112-1:2014-04 (p. 9.3.2) LV 112-2:2007-11 (p. 8.4.2) LV 112-2:2013-04 (p. 9.3.2) LV 212-1:2015-01 (p. 9.3.2) LV 216-1:2015-07 (p. 9.3.2) LV 212-2:2015-01 (p. 9.3.2) LV 216-2:2017-02 (p. 9.3.2) VW 60306-1:2018-09-01 (p. 9.3.2) VW 60306-1:2021-10 (p. 9.4.2) VW 60306-2:2013-04 (p. 9.3.2) VW 60306-2:2021-11 (p. 9.4.2) VW 60306-4:2021-12 (p. 9.4.2) VW 75209-1:2015-01 (p. 9.3.2) VW 75209-1:2021-12 (p. 9.4.2) VW 75209-2:2015-01 (p. 9.3.2) VW 75209-2:2021-12 (p. 9.4.1) VW 75210-1:2023-06 (p. 9.4.2) VW 75210-1:2024-08 (p. 9.4.2) VW 75210-2:2023-06 (p. 9.4.2) MBN LV 112-1:2016-03 (p. 9.3.2) MBN 50112-1:2023-06 (p. 12.3.3) MBN LV 112-2:2012-01 (p. 8.4.2) MBN 50112-2:2023-05 (p. 12.4.2) MBN 50216-1:2023-07 (p. 12.4.3) MBN LV 212-1:2017-08 (p. 9.3.2) MBN 50212-1:2023-04 (p. 12.4.2) MBN LV 216-2:2017-07 (p. 9.3.2) MBN 50112-4:2024-06 (p. 12.3.3) GS 95007-1-1:2013-05 (p. 9.3.2) GS 95007-1-2:2013-05 (p. 9.3.2) GS 95007-3-1:2015-08 (p. 9.3.2) GS 95007-3-2:2015-09 (p. 9.3.2) GS 95007-6-1:2016-03 (p. 9.3.2) GS 95007-6-2:2017-04 (p. 9.3.2) Kable, Cables Odpornosc izolacji / powloki kabla na przetarcie ISO 19642-2 2019-01 (p. 5.3.2.5) | ISO 19642-2:2023 (p. 5.4.2.5; 6.4.8.6) | ISO 19642-3:2019-01 (p. 5.4.2.3) | ISO 19642-4:2019-01 (p. 5.4.2.3) | ISO 19642-5:2019-01 (p. 5.4.2.3) | ISO 19642-6:2019-01 (p. 5.4.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.12.4.2) | ISO 6722-2:2013-12-01 (p. 5.12) LV 112-1:2013-04 (p. 9.3.2) LV 112-1:2014-04 (p. 9.3.2) LV 112-2:2007-11 (p. 8.4.2) LV 112-2:2013-04 (p. 9.3.2) LV 212-1:2015-01 (p. 9.3.2) LV 216-1:2015-07 (p. 9.3.2) LV 212-2:2015-01 (p. 9.3.2) LV 216-2:2017-02 (p. 9.3.2) VW 60306-1:2018-09-01 (p. 9.3.2) VW 60306-1:2021-10 (p. 9.4.2) VW 60306-2:2013-04 (p. 9.3.2) VW 60306-2:2021-11 (p. 9.4.2) VW 60306-4:2021-12 (p. 9.4.2) VW 75209-1:2015-01 (p. 9.3.2) VW 75209-1:2021-12 (p. 9.4.2) VW 75209-2:2015-01 (p. 9.3.2) VW 75209-2:2021-12 (p. 9.4.1) VW 75210-1:2023-06 (p. 9.4.2) VW 75210-1:2024-08 (p. 9.4.2) VW 75210-2:2023-06 (p. 9.4.2) MBN LV 112-1:2016-03 (p. 9.3.2) MBN 50112-1:2023-06 (p. 12.3.3) MBN LV 112-2:2012-01 (p. 8.4.2) MBN 50112-2:2023-05 (p. 12.4.2) MBN 50216-1:2023-07 (p. 12.4.3) MBN LV 212-1:2017-08 (p. 9.3.2) MBN 50212-1:2023-04 (p. 12.4.2) MBN LV 216-2:2017-07 (p. 9.3.2) MBN 50112-4:2024-06 (p. 12.3.3) GS 95007-1-1:2013-05 (p. 9.3.2) GS 95007-1-2:2013-05 (p. 9.3.2) GS 95007-3-1:2015-08 (p. 9.3.2) GS 95007-3-2:2015-09 (p. 9.3.2) GS 95007-6-1:2016-03 (p. 9.3.2) GS 95007-6-2:2017-04 (p. 9.3.2)","categories":["construction"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Resistance of cable insulation / sheath to abrasion ISO 19642-2 2019-01 (p. 5.3.2.5) | ISO 19642-2:2023 (p. 5.4.2.5; 6.4.8.6) | ISO 19642-3:2019-01 (p. 5.4.2.3) | ISO 19642-4:2019-01 (p. 5.4.2.3) | ISO 19642-5:2019-01 (p. 5.4.2.3) | ISO 19642-6:2019-01 (p. 5.4.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.12.4.2) | ISO 6722-2:2013-12-01 (p. 5.12) LV 112-1:2013-04 (p. 9.3.2) LV 112-1:2014-04 (p. 9.3.2) LV 112-2:2007-11 (p. 8.4.2) LV 112-2:2013-04 (p. 9.3.2) LV 212-1:2015-01 (p. 9.3.2) LV 216-1:2015-07 (p. 9.3.2) LV 212-2:2015-01 (p. 9.3.2) LV 216-2:2017-02 (p. 9.3.2) VW 60306-1:2018-09-01 (p. 9.3.2) VW 60306-1:2021-10 (p. 9.4.2) VW 60306-2:2013-04 (p. 9.3.2) VW 60306-2:2021-11 (p. 9.4.2) VW 60306-4:2021-12 (p. 9.4.2) VW 75209-1:2015-01 (p. 9.3.2) VW 75209-1:2021-12 (p. 9.4.2) VW 75209-2:2015-01 (p. 9.3.2) VW 75209-2:2021-12 (p. 9.4.1) VW 75210-1:2023-06 (p. 9.4.2) VW 75210-1:2024-08 (p. 9.4.2) VW 75210-2:2023-06 (p. 9.4.2) MBN LV 112-1:2016-03 (p. 9.3.2) MBN 50112-1:2023-06 (p. 12.3.3) MBN LV 112-2:2012-01 (p. 8.4.2) MBN 50112-2:2023-05 (p. 12.4.2) MBN 50216-1:2023-07 (p. 12.4.3) MBN LV 212-1:2017-08 (p. 9.3.2) MBN 50212-1:2023-04 (p. 12.4.2) MBN LV 216-2:2017-07 (p. 9.3.2) MBN 50112-4:2024-06 (p. 12.3.3) GS 95007-1-1:2013-05 (p. 9.3.2) GS 95007-1-2:2013-05 (p. 9.3.2) GS 95007-3-1:2015-08 (p. 9.3.2) GS 95007-3-2:2015-09 (p. 9.3.2) GS 95007-6-1:2016-03 (p. 9.3.2) GS 95007-6-2:2017-04 (p. 9.3.2)","search_zh":"电缆 ISO 19642-2 2019-01 (p. 5.3.2.5) | ISO 19642-2:2023 (p. 5.4.2.5; 6.4.8.6) | ISO 19642-3:2019-01 (p. 5.4.2.3) | ISO 19642-4:2019-01 (p. 5.4.2.3) | ISO 19642-5:2019-01 (p. 5.4.2.3) | ISO 19642-6:2019-01 (p. 5.4.2.3) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.12.4.2) | ISO 6722-2:2013-12-01 (p. 5.12) LV 112-1:2013-04 (p. 9.3.2) LV 112-1:2014-04 (p. 9.3.2) LV 112-2:2007-11 (p. 8.4.2) LV 112-2:2013-04 (p. 9.3.2) LV 212-1:2015-01 (p. 9.3.2) LV 216-1:2015-07 (p. 9.3.2) LV 212-2:2015-01 (p. 9.3.2) LV 216-2:2017-02 (p. 9.3.2) VW 60306-1:2018-09-01 (p. 9.3.2) VW 60306-1:2021-10 (p. 9.4.2) VW 60306-2:2013-04 (p. 9.3.2) VW 60306-2:2021-11 (p. 9.4.2) VW 60306-4:2021-12 (p. 9.4.2) VW 75209-1:2015-01 (p. 9.3.2) VW 75209-1:2021-12 (p. 9.4.2) VW 75209-2:2015-01 (p. 9.3.2) VW 75209-2:2021-12 (p. 9.4.1) VW 75210-1:2023-06 (p. 9.4.2) VW 75210-1:2024-08 (p. 9.4.2) VW 75210-2:2023-06 (p. 9.4.2) MBN LV 112-1:2016-03 (p. 9.3.2) MBN 50112-1:2023-06 (p. 12.3.3) MBN LV 112-2:2012-01 (p. 8.4.2) MBN 50112-2:2023-05 (p. 12.4.2) MBN 50216-1:2023-07 (p. 12.4.3) MBN LV 212-1:2017-08 (p. 9.3.2) MBN 50212-1:2023-04 (p. 12.4.2) MBN LV 216-2:2017-07 (p. 9.3.2) MBN 50112-4:2024-06 (p. 12.3.3) GS 95007-1-1:2013-05 (p. 9.3.2) GS 95007-1-2:2013-05 (p. 9.3.2) GS 95007-3-1:2015-08 (p. 9.3.2) GS 95007-3-2:2015-09 (p. 9.3.2) GS 95007-6-1:2016-03 (p. 9.3.2) GS 95007-6-2:2017-04 (p. 9.3.2)","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ecd","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Siła zrywająca gotowy kabel","methodology_en":"Breaking force of the finished cable","parameters":[{"name":"Maszyna wytrzymałościowa","range":"do 20 kN"}],"parameters_en":[{"name":"Testing machine","range":"do 20 kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła zrywająca gotowy kabel\nMaszyna wytrzymałościowa do 20 kN","reference":"ISO 19642-2:2019-01 (p. 5.3.3) | ISO 19642-2:2023 (p. 5.4.3) | ISO 19642-3:2019-01 (p. 5.4.3) | ISO 19642-4:2019-01 (p. 5.4.3) | ISO 19642-5:2019-01 (p. 5.4.3) | ISO 19642-6:2019-01 (p. 5.4.3) Scope of accreditation No. AB 1776","norm_bases":["ISO 19642-2:2019-01 (p. 5.3.3)","ISO 19642-2:2023 (p. 5.4.3)","ISO 19642-3:2019-01 (p. 5.4.3)","ISO 19642-4:2019-01 (p. 5.4.3)","ISO 19642-5:2019-01 (p. 5.4.3)","ISO 19642-6:2019-01 (p. 5.4.3) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Siła zrywająca gotowy kabel\nMaszyna wytrzymałościowa do 20 kN ISO 19642-2:2019-01 (p. 5.3.3) | ISO 19642-2:2023 (p. 5.4.3) | ISO 19642-3:2019-01 (p. 5.4.3) | ISO 19642-4:2019-01 (p. 5.4.3) | ISO 19642-5:2019-01 (p. 5.4.3) | ISO 19642-6:2019-01 (p. 5.4.3) Scope of accreditation No. AB 1776 Kable, Cables Sila zrywajaca gotowy kabel\nMaszyna wytrzymalosciowa do 20 kN ISO 19642-2:2019-01 (p. 5.3.3) | ISO 19642-2:2023 (p. 5.4.3) | ISO 19642-3:2019-01 (p. 5.4.3) | ISO 19642-4:2019-01 (p. 5.4.3) | ISO 19642-5:2019-01 (p. 5.4.3) | ISO 19642-6:2019-01 (p. 5.4.3) Scope of accreditation No. AB 1776","categories":["other"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Breaking force of the finished cable Testing machine ISO 19642-2:2019-01 (p. 5.3.3) | ISO 19642-2:2023 (p. 5.4.3) | ISO 19642-3:2019-01 (p. 5.4.3) | ISO 19642-4:2019-01 (p. 5.4.3) | ISO 19642-5:2019-01 (p. 5.4.3) | ISO 19642-6:2019-01 (p. 5.4.3) Scope of accreditation No. AB 1776","search_zh":"电缆 材料试验机 ISO 19642-2:2019-01 (p. 5.3.3) | ISO 19642-2:2023 (p. 5.4.3) | ISO 19642-3:2019-01 (p. 5.4.3) | ISO 19642-4:2019-01 (p. 5.4.3) | ISO 19642-5:2019-01 (p. 5.4.3) | ISO 19642-6:2019-01 (p. 5.4.3) Scope of accreditation No. AB 1776","test_object_zh":"电缆","parameters_zh":[{"name":"材料试验机","range":"do 20 kN"}]},{"_id":"6a5dc9a9f1c10c8ce8259ece","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Test elastyczności kabla","methodology_en":"Cable flexibility test","parameters":[{"name":"kable o średnicy zewnętrznej ≤ 28 mm"}],"parameters_en":[{"name":"cables with outer diameter ≤ 28 mm"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Test elastyczności kabla\nkable o średnicy zewnętrznej ≤ 28 mm","reference":"ISO 19642-2:2019-01 (p. 5.3.5; 6.3.3) | ISO 19642-2:2023 (p. 5.4.5; 6.4.3) | ISO 19642-3:2019-01 (p. 5.4.5) | ISO 19642-4:2019-01 (p. 5.4.5) | ISO 19642-5:2019-01 (p. 5.4.5) | ISO 19642-6:2019-01 (p. 5.4.5) | ISO 19642-7:2019-01 (p. 6.4.3) | ISO 19642-8:2019-01 (p. 6.4.3) | ISO 19642-9:2019-01 (p. 6.4.3) | ISO 19642-10:2019-01 (p. 6.4.3)","norm_bases":["ISO 19642-2:2019-01 (p. 5.3.5; 6.3.3)","ISO 19642-2:2023 (p. 5.4.5; 6.4.3)","ISO 19642-3:2019-01 (p. 5.4.5)","ISO 19642-4:2019-01 (p. 5.4.5)","ISO 19642-5:2019-01 (p. 5.4.5)","ISO 19642-6:2019-01 (p. 5.4.5)","ISO 19642-7:2019-01 (p. 6.4.3)","ISO 19642-8:2019-01 (p. 6.4.3)","ISO 19642-9:2019-01 (p. 6.4.3)","ISO 19642-10:2019-01 (p. 6.4.3)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Test elastyczności kabla\nkable o średnicy zewnętrznej ≤ 28 mm ISO 19642-2:2019-01 (p. 5.3.5; 6.3.3) | ISO 19642-2:2023 (p. 5.4.5; 6.4.3) | ISO 19642-3:2019-01 (p. 5.4.5) | ISO 19642-4:2019-01 (p. 5.4.5) | ISO 19642-5:2019-01 (p. 5.4.5) | ISO 19642-6:2019-01 (p. 5.4.5) | ISO 19642-7:2019-01 (p. 6.4.3) | ISO 19642-8:2019-01 (p. 6.4.3) | ISO 19642-9:2019-01 (p. 6.4.3) | ISO 19642-10:2019-01 (p. 6.4.3) Kable, Cables Test elastycznosci kabla\nkable o srednicy zewnetrznej ≤ 28 mm ISO 19642-2:2019-01 (p. 5.3.5; 6.3.3) | ISO 19642-2:2023 (p. 5.4.5; 6.4.3) | ISO 19642-3:2019-01 (p. 5.4.5) | ISO 19642-4:2019-01 (p. 5.4.5) | ISO 19642-5:2019-01 (p. 5.4.5) | ISO 19642-6:2019-01 (p. 5.4.5) | ISO 19642-7:2019-01 (p. 6.4.3) | ISO 19642-8:2019-01 (p. 6.4.3) | ISO 19642-9:2019-01 (p. 6.4.3) | ISO 19642-10:2019-01 (p. 6.4.3)","categories":["other"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Cable flexibility test cables with outer diameter ≤ 28 mm ISO 19642-2:2019-01 (p. 5.3.5; 6.3.3) | ISO 19642-2:2023 (p. 5.4.5; 6.4.3) | ISO 19642-3:2019-01 (p. 5.4.5) | ISO 19642-4:2019-01 (p. 5.4.5) | ISO 19642-5:2019-01 (p. 5.4.5) | ISO 19642-6:2019-01 (p. 5.4.5) | ISO 19642-7:2019-01 (p. 6.4.3) | ISO 19642-8:2019-01 (p. 6.4.3) | ISO 19642-9:2019-01 (p. 6.4.3) | ISO 19642-10:2019-01 (p. 6.4.3)","search_zh":"电缆 ISO 19642-2:2019-01 (p. 5.3.5; 6.3.3) | ISO 19642-2:2023 (p. 5.4.5; 6.4.3) | ISO 19642-3:2019-01 (p. 5.4.5) | ISO 19642-4:2019-01 (p. 5.4.5) | ISO 19642-5:2019-01 (p. 5.4.5) | ISO 19642-6:2019-01 (p. 5.4.5) | ISO 19642-7:2019-01 (p. 6.4.3) | ISO 19642-8:2019-01 (p. 6.4.3) | ISO 19642-9:2019-01 (p. 6.4.3) | ISO 19642-10:2019-01 (p. 6.4.3)","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ecf","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Test nawijania kabla","methodology_en":"Cable winding test","parameters":[{"name":"Komora klimatyczna: - 40 °C","range":"do 125 °C"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV do 6 kV D.C."}],"parameters_en":[{"name":"Climatic chamber: - 40 °C","range":"do 125 °C"},{"name":"Range","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Test nawijania kabla\nZakres:\nKomora klimatyczna: - 40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C.","reference":"ISO 19642-2:2019-01 (p. 5.4.1; 6.4.1) | ISO 19642-2:2023 (p. 5.5.1; 6.5.1) | ISO 19642-3:2019-01 (p. 5.5.1) | ISO 19642-4:2019-01 (p. 5.5.1) | ISO 19642-5:2019-01 (p. 5.5.1) | ISO 19642-6:2019-01 (p. 5.5.1) | ISO 19642-7:2019-01 (p. 6.5.1) | ISO 19642-8:2019-01 (p. 6.5.1) | ISO 19642-9:2019-01 (p. 6.5.1) | ISO 19642-10:2019-01 (p. 6.5.1)","norm_bases":["ISO 19642-2:2019-01 (p. 5.4.1; 6.4.1)","ISO 19642-2:2023 (p. 5.5.1; 6.5.1)","ISO 19642-3:2019-01 (p. 5.5.1)","ISO 19642-4:2019-01 (p. 5.5.1)","ISO 19642-5:2019-01 (p. 5.5.1)","ISO 19642-6:2019-01 (p. 5.5.1)","ISO 19642-7:2019-01 (p. 6.5.1)","ISO 19642-8:2019-01 (p. 6.5.1)","ISO 19642-9:2019-01 (p. 6.5.1)","ISO 19642-10:2019-01 (p. 6.5.1)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Test nawijania kabla\nZakres:\nKomora klimatyczna: - 40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. ISO 19642-2:2019-01 (p. 5.4.1; 6.4.1) | ISO 19642-2:2023 (p. 5.5.1; 6.5.1) | ISO 19642-3:2019-01 (p. 5.5.1) | ISO 19642-4:2019-01 (p. 5.5.1) | ISO 19642-5:2019-01 (p. 5.5.1) | ISO 19642-6:2019-01 (p. 5.5.1) | ISO 19642-7:2019-01 (p. 6.5.1) | ISO 19642-8:2019-01 (p. 6.5.1) | ISO 19642-9:2019-01 (p. 6.5.1) | ISO 19642-10:2019-01 (p. 6.5.1) Kable, Cables Test nawijania kabla\nZakres:\nKomora klimatyczna: - 40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. ISO 19642-2:2019-01 (p. 5.4.1; 6.4.1) | ISO 19642-2:2023 (p. 5.5.1; 6.5.1) | ISO 19642-3:2019-01 (p. 5.5.1) | ISO 19642-4:2019-01 (p. 5.5.1) | ISO 19642-5:2019-01 (p. 5.5.1) | ISO 19642-6:2019-01 (p. 5.5.1) | ISO 19642-7:2019-01 (p. 6.5.1) | ISO 19642-8:2019-01 (p. 6.5.1) | ISO 19642-9:2019-01 (p. 6.5.1) | ISO 19642-10:2019-01 (p. 6.5.1)","categories":["other"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Cable winding test Climatic chamber: - 40 °C Range 0,5 kV to 6 kV D.C. ISO 19642-2:2019-01 (p. 5.4.1; 6.4.1) | ISO 19642-2:2023 (p. 5.5.1; 6.5.1) | ISO 19642-3:2019-01 (p. 5.5.1) | ISO 19642-4:2019-01 (p. 5.5.1) | ISO 19642-5:2019-01 (p. 5.5.1) | ISO 19642-6:2019-01 (p. 5.5.1) | ISO 19642-7:2019-01 (p. 6.5.1) | ISO 19642-8:2019-01 (p. 6.5.1) | ISO 19642-9:2019-01 (p. 6.5.1) | ISO 19642-10:2019-01 (p. 6.5.1)","parameters_zh":[{"name":"气候试验箱：- 40 °C","range":"do 125 °C"},{"name":"范围","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV do 6 kV D.C."}],"search_zh":"电缆 气候试验箱：- 40 °C 范围 ISO 19642-2:2019-01 (p. 5.4.1; 6.4.1) | ISO 19642-2:2023 (p. 5.5.1; 6.5.1) | ISO 19642-3:2019-01 (p. 5.5.1) | ISO 19642-4:2019-01 (p. 5.5.1) | ISO 19642-5:2019-01 (p. 5.5.1) | ISO 19642-6:2019-01 (p. 5.5.1) | ISO 19642-7:2019-01 (p. 6.5.1) | ISO 19642-8:2019-01 (p. 6.5.1) | ISO 19642-9:2019-01 (p. 6.5.1) | ISO 19642-10:2019-01 (p. 6.5.1)","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ed0","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Badania starzeniowe:","methodology_en":"Ageing tests:","parameters":[{"name":"długotrwałe starzenie kabla","range":"(3000 h)"},{"name":"krótkotrwałe starzenie kabla","range":"(240 h)"},{"name":"przeciążenie cieplne kabli"},{"name":"starzenie krótkotrwałe PVC"},{"name":"Piec","range":"do 200 °C (± 2 °C)"},{"name":"Komora klimatyczna: - 40 °C","range":"do 125 °C"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV do 6 kV D.C."}],"parameters_en":[{"name":"long-term cable ageing","range":"(3000 h)"},{"name":"short-term cable ageing","range":"(240 h)"},{"name":"thermal overload of cables"},{"name":"short-term ageing of PVC"},{"name":"Stove","range":"do 200 °C (± 2 °C)"},{"name":"Climatic chamber: - 40 °C","range":"do 125 °C"},{"name":"Range","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania starzeniowe:\nZakres:\ndługotrwałe starzenie kabla (3000 h)\nkrótkotrwałe starzenie kabla (240 h)\nprzeciążenie cieplne kabli\nstarzenie krótkotrwałe PVC\nPiec do 200 °C (± 2 °C)\nKomora klimatyczna: - 40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C.","reference":"ISO 19642-2:2019-01 (p. 5.4.2; 5.4.3; 5.4.4; 6.4.2; 6.4.3; 6.4.4) | ISO 19642-2:2023 (p. 5.5.2; 5.5.3; 5.5.4; 6.5.2; 6.5.3; 6.5.4) | ISO 19642-3:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-4:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-5:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-6:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-7:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-8:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-9: 2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-10:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.13; 5.14; 5.15) | ISO 6722-2:2013-12-01 (p. 5.13; 5.14; 5.15) | ISO 14572:2011-10 (p. 5.13; 5.14; 5.15) LV 112-1:2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1; 9.6.6) LV 112-1:2014-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1; 9.7.6) LV 112-2:2007-11 (p. 8.7.6; 8.7.5; 8.7.7) LV 112-2: 2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) LV 122:2015-05 (p. 11.5.1.1; 11.5.1.2) LV 122:2016-02 (p. 11.5.5; 11.5.5.2) LV 212-1:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) LV 212-2:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) LV 216-1:2015-07 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) LV 216-2:2017-02 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) Scope of accreditation No. AB 1776","norm_bases":["ISO 19642-2:2019-01 (p. 5.4.2; 5.4.3; 5.4.4; 6.4.2; 6.4.3; 6.4.4)","ISO 19642-2:2023 (p. 5.5.2; 5.5.3; 5.5.4; 6.5.2; 6.5.3; 6.5.4)","ISO 19642-3:2019-01 (p. 5.5.2; 5.5.3; 5.5.4)","ISO 19642-4:2019-01 (p. 5.5.2; 5.5.3; 5.5.4)","ISO 19642-5:2019-01 (p. 5.5.2; 5.5.3; 5.5.4)","ISO 19642-6:2019-01 (p. 5.5.2; 5.5.3; 5.5.4)","ISO 19642-7:2019-01 (p. 6.5.2; 6.5.3; 6.5.4)","ISO 19642-8:2019-01 (p. 6.5.2; 6.5.3; 6.5.4)","ISO 19642-9: 2019-01 (p. 6.5.2; 6.5.3; 6.5.4)","ISO 19642-10:2019-01 (p. 6.5.2; 6.5.3; 6.5.4)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.13; 5.14; 5.15)","ISO 6722-2:2013-12-01 (p. 5.13; 5.14; 5.15)","ISO 14572:2011-10 (p. 5.13; 5.14; 5.15) LV 112-1:2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1; 9.6.6) LV 112-1:2014-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1; 9.7.6) LV 112-2:2007-11 (p. 8.7.6; 8.7.5; 8.7.7) LV 112-2: 2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) LV 122:2015-05 (p. 11.5.1.1; 11.5.1.2) LV 122:2016-02 (p. 11.5.5; 11.5.5.2) LV 212-1:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) LV 212-2:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) LV 216-1:2015-07 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) LV 216-2:2017-02 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Badania starzeniowe:\nZakres:\ndługotrwałe starzenie kabla (3000 h)\nkrótkotrwałe starzenie kabla (240 h)\nprzeciążenie cieplne kabli\nstarzenie krótkotrwałe PVC\nPiec do 200 °C (± 2 °C)\nKomora klimatyczna: - 40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. ISO 19642-2:2019-01 (p. 5.4.2; 5.4.3; 5.4.4; 6.4.2; 6.4.3; 6.4.4) | ISO 19642-2:2023 (p. 5.5.2; 5.5.3; 5.5.4; 6.5.2; 6.5.3; 6.5.4) | ISO 19642-3:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-4:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-5:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-6:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-7:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-8:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-9: 2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-10:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.13; 5.14; 5.15) | ISO 6722-2:2013-12-01 (p. 5.13; 5.14; 5.15) | ISO 14572:2011-10 (p. 5.13; 5.14; 5.15) LV 112-1:2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1; 9.6.6) LV 112-1:2014-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1; 9.7.6) LV 112-2:2007-11 (p. 8.7.6; 8.7.5; 8.7.7) LV 112-2: 2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) LV 122:2015-05 (p. 11.5.1.1; 11.5.1.2) LV 122:2016-02 (p. 11.5.5; 11.5.5.2) LV 212-1:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) LV 212-2:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) LV 216-1:2015-07 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) LV 216-2:2017-02 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) Scope of accreditation No. AB 1776 Kable, Cables Badania starzeniowe:\nZakres:\ndlugotrwale starzenie kabla (3000 h)\nkrotkotrwale starzenie kabla (240 h)\nprzeciazenie cieplne kabli\nstarzenie krotkotrwale PVC\nPiec do 200 °C (± 2 °C)\nKomora klimatyczna: - 40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. ISO 19642-2:2019-01 (p. 5.4.2; 5.4.3; 5.4.4; 6.4.2; 6.4.3; 6.4.4) | ISO 19642-2:2023 (p. 5.5.2; 5.5.3; 5.5.4; 6.5.2; 6.5.3; 6.5.4) | ISO 19642-3:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-4:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-5:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-6:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-7:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-8:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-9: 2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-10:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.13; 5.14; 5.15) | ISO 6722-2:2013-12-01 (p. 5.13; 5.14; 5.15) | ISO 14572:2011-10 (p. 5.13; 5.14; 5.15) LV 112-1:2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1; 9.6.6) LV 112-1:2014-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1; 9.7.6) LV 112-2:2007-11 (p. 8.7.6; 8.7.5; 8.7.7) LV 112-2: 2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) LV 122:2015-05 (p. 11.5.1.1; 11.5.1.2) LV 122:2016-02 (p. 11.5.5; 11.5.5.2) LV 212-1:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) LV 212-2:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) LV 216-1:2015-07 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) LV 216-2:2017-02 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) Scope of accreditation No. AB 1776","categories":["other"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Ageing tests: long-term cable ageing short-term cable ageing thermal overload of cables short-term ageing of PVC Stove Climatic chamber: - 40 °C Range 0,5 kV to 6 kV D.C. ISO 19642-2:2019-01 (p. 5.4.2; 5.4.3; 5.4.4; 6.4.2; 6.4.3; 6.4.4) | ISO 19642-2:2023 (p. 5.5.2; 5.5.3; 5.5.4; 6.5.2; 6.5.3; 6.5.4) | ISO 19642-3:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-4:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-5:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-6:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-7:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-8:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-9: 2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-10:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.13; 5.14; 5.15) | ISO 6722-2:2013-12-01 (p. 5.13; 5.14; 5.15) | ISO 14572:2011-10 (p. 5.13; 5.14; 5.15) LV 112-1:2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1; 9.6.6) LV 112-1:2014-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1; 9.7.6) LV 112-2:2007-11 (p. 8.7.6; 8.7.5; 8.7.7) LV 112-2: 2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) LV 122:2015-05 (p. 11.5.1.1; 11.5.1.2) LV 122:2016-02 (p. 11.5.5; 11.5.5.2) LV 212-1:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) LV 212-2:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) LV 216-1:2015-07 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) LV 216-2:2017-02 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"电缆长期老化","range":"(3000 h)"},{"name":"电缆短期老化","range":"(240 h)"},{"name":"电缆热过载"},{"name":"starzenie krótkotrwałe PVC"},{"name":"炉窑","range":"do 200 °C (± 2 °C)"},{"name":"气候试验箱：- 40 °C","range":"do 125 °C"},{"name":"范围","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV do 6 kV D.C."}],"search_zh":"电缆 老化检验： 电缆长期老化 电缆短期老化 电缆热过载 炉窑 气候试验箱：- 40 °C 范围 ISO 19642-2:2019-01 (p. 5.4.2; 5.4.3; 5.4.4; 6.4.2; 6.4.3; 6.4.4) | ISO 19642-2:2023 (p. 5.5.2; 5.5.3; 5.5.4; 6.5.2; 6.5.3; 6.5.4) | ISO 19642-3:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-4:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-5:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-6:2019-01 (p. 5.5.2; 5.5.3; 5.5.4) | ISO 19642-7:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-8:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-9: 2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 19642-10:2019-01 (p. 6.5.2; 6.5.3; 6.5.4) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.13; 5.14; 5.15) | ISO 6722-2:2013-12-01 (p. 5.13; 5.14; 5.15) | ISO 14572:2011-10 (p. 5.13; 5.14; 5.15) LV 112-1:2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1; 9.6.6) LV 112-1:2014-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1; 9.7.6) LV 112-2:2007-11 (p. 8.7.6; 8.7.5; 8.7.7) LV 112-2: 2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) LV 122:2015-05 (p. 11.5.1.1; 11.5.1.2) LV 122:2016-02 (p. 11.5.5; 11.5.5.2) LV 212-1:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) LV 212-2:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) LV 216-1:2015-07 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) LV 216-2:2017-02 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) Scope of accreditation No. AB 1776","test_object_zh":"电缆","methodology_zh":"老化检验："},{"_id":"6a5dc9a9f1c10c8ce8259ed1","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"","methodology_en":null,"parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"","reference":"VW 60306-1:2018-09-01 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) VW 60306-1:2021-10 (p. 9.7.7; 9.7.6.1; 9.7.7.2; 9.7.8; 9.7.8.2) VW 60306-2:2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) VW 60306-2:2021-11 (p. 9.7.7; 9.7.7.2; 9.7.6.1; 9.7.8; 9.7.8.2) VW 60306-4:2021-12 (p. 9.7.6.1; 9.7.7; 9.7.7.2; 9.7.8; 9.7.8.2)","norm_bases":["VW 60306-1:2018-09-01 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) VW 60306-1:2021-10 (p. 9.7.7; 9.7.6.1; 9.7.7.2; 9.7.8; 9.7.8.2) VW 60306-2:2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) VW 60306-2:2021-11 (p. 9.7.7; 9.7.7.2; 9.7.6.1; 9.7.8; 9.7.8.2) VW 60306-4:2021-12 (p. 9.7.6.1; 9.7.7; 9.7.7.2; 9.7.8; 9.7.8.2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables VW 60306-1:2018-09-01 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) VW 60306-1:2021-10 (p. 9.7.7; 9.7.6.1; 9.7.7.2; 9.7.8; 9.7.8.2) VW 60306-2:2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) VW 60306-2:2021-11 (p. 9.7.7; 9.7.7.2; 9.7.6.1; 9.7.8; 9.7.8.2) VW 60306-4:2021-12 (p. 9.7.6.1; 9.7.7; 9.7.7.2; 9.7.8; 9.7.8.2) Kable, Cables VW 60306-1:2018-09-01 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) VW 60306-1:2021-10 (p. 9.7.7; 9.7.6.1; 9.7.7.2; 9.7.8; 9.7.8.2) VW 60306-2:2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) VW 60306-2:2021-11 (p. 9.7.7; 9.7.7.2; 9.7.6.1; 9.7.8; 9.7.8.2) VW 60306-4:2021-12 (p. 9.7.6.1; 9.7.7; 9.7.7.2; 9.7.8; 9.7.8.2)","categories":["other"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables VW 60306-1:2018-09-01 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) VW 60306-1:2021-10 (p. 9.7.7; 9.7.6.1; 9.7.7.2; 9.7.8; 9.7.8.2) VW 60306-2:2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) VW 60306-2:2021-11 (p. 9.7.7; 9.7.7.2; 9.7.6.1; 9.7.8; 9.7.8.2) VW 60306-4:2021-12 (p. 9.7.6.1; 9.7.7; 9.7.7.2; 9.7.8; 9.7.8.2)","search_zh":"电缆 VW 60306-1:2018-09-01 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) VW 60306-1:2021-10 (p. 9.7.7; 9.7.6.1; 9.7.7.2; 9.7.8; 9.7.8.2) VW 60306-2:2013-04 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) VW 60306-2:2021-11 (p. 9.7.7; 9.7.7.2; 9.7.6.1; 9.7.8; 9.7.8.2) VW 60306-4:2021-12 (p. 9.7.6.1; 9.7.7; 9.7.7.2; 9.7.8; 9.7.8.2)","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ed2","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Badania starzeniowe:","methodology_en":"Ageing tests:","parameters":[{"name":"długotrwałe starzenie kabla","range":"(3000 h)"},{"name":"krótkotrwałe starzenie kabla","range":"(240 h)"},{"name":"przeciążenie cieplne kabli"},{"name":"starzenie krótkotrwałe PVC"},{"name":"Piec","range":"do 200 °C (± 2 °C)"},{"name":"Komora klimatyczna: - 40 °C","range":"do 125 °C"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV do 6 kV D.C."}],"parameters_en":[{"name":"long-term cable ageing","range":"(3000 h)"},{"name":"short-term cable ageing","range":"(240 h)"},{"name":"thermal overload of cables"},{"name":"short-term ageing of PVC"},{"name":"Stove","range":"do 200 °C (± 2 °C)"},{"name":"Climatic chamber: - 40 °C","range":"do 125 °C"},{"name":"Range","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania starzeniowe:\nZakres:\ndługotrwałe starzenie kabla (3000 h)\nkrótkotrwałe starzenie kabla (240 h)\nprzeciążenie cieplne kabli\nstarzenie krótkotrwałe PVC\nPiec do 200 °C (± 2 °C)\nKomora klimatyczna: - 40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C.","reference":"VW 75205:2019-11 (p. 11.5.1.1; 11.5.1.2) VW 75205:2023-05 (p. 11.5.1.1; 11.5.1.2) VW 75205:2024-04 (p. 11.6.1.1; 11.6.1.2) VW 75209-1:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) VW 75209-1:2021-12 (p. 9.7.5; 9.7.5.2; 9.7.4; 9.7.6; 9.7.6.2) VW 75209-2:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) VW 75209-2:2021-12 (p.9.7.4; 9.7.5.2; 9.7.3; 9.7.6; 9.7.6.2; 9.7.5) VW 75210-1:2023-06 (p. 9.7.6; 9.7.6.1; 9.7.6.2; 9.7.7; 9.7.8; 9.7.8.1) VW 75210-1:2024-08 (p. 9.7.6, 9.7.6.1; 9.7.6.2; 9.7.7; 9.7.7.1; 9.7.8; 9.7.8.1) VW 75210-2:2023-06 (p. 9.7.5; 9.7.6; 9.7.7; 9.7.7.1) MBN LV 112-1:2016-03 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) MBN LV 122:2017-06 (p. 11.5.5; 11.5.5.2) MBN 50122:2023-07 (p. 13.5.5; 13.5.5.2) MBN LV 212-1:2017-08 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) MBN 50212-1:2023-04 (p. 12.7.5; 12.7.6; 12.7.6.1; 12.7.6.2; 12.7.7; 12.7.7.1; 12.7.7.2) MBN LV 216-2:2017-07 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) GS 95007-1-1:2013-05 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) GS 95007-1-2:2013-05 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) GS 95007-1-5:2015-07 (p. 11.5.1.1; 11.5.1.2) GS 95007-3-1:2015-08 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) GS 95007-3-2:2015-09 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) GS 95007-6-1:2016-03 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) GS 95007-6-2:2017-04 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) MBN 50112-1:2023-06 (12.6.6.1; 12.6.7.1; 12.6.7.2; 12.6.8.1; 12.6.8.2) Scope of accreditation No. AB 1776","norm_bases":["VW 75205:2019-11 (p. 11.5.1.1; 11.5.1.2) VW 75205:2023-05 (p. 11.5.1.1; 11.5.1.2) VW 75205:2024-04 (p. 11.6.1.1; 11.6.1.2) VW 75209-1:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) VW 75209-1:2021-12 (p. 9.7.5; 9.7.5.2; 9.7.4; 9.7.6; 9.7.6.2) VW 75209-2:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) VW 75209-2:2021-12 (p.9.7.4; 9.7.5.2; 9.7.3; 9.7.6; 9.7.6.2; 9.7.5) VW 75210-1:2023-06 (p. 9.7.6; 9.7.6.1; 9.7.6.2; 9.7.7; 9.7.8; 9.7.8.1) VW 75210-1:2024-08 (p. 9.7.6, 9.7.6.1; 9.7.6.2; 9.7.7; 9.7.7.1; 9.7.8; 9.7.8.1) VW 75210-2:2023-06 (p. 9.7.5; 9.7.6; 9.7.7; 9.7.7.1) MBN LV 112-1:2016-03 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) MBN LV 122:2017-06 (p. 11.5.5; 11.5.5.2) MBN 50122:2023-07 (p. 13.5.5; 13.5.5.2) MBN LV 212-1:2017-08 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) MBN 50212-1:2023-04 (p. 12.7.5; 12.7.6; 12.7.6.1; 12.7.6.2; 12.7.7; 12.7.7.1; 12.7.7.2) MBN LV 216-2:2017-07 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) GS 95007-1-1:2013-05 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) GS 95007-1-2:2013-05 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) GS 95007-1-5:2015-07 (p. 11.5.1.1; 11.5.1.2) GS 95007-3-1:2015-08 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) GS 95007-3-2:2015-09 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) GS 95007-6-1:2016-03 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) GS 95007-6-2:2017-04 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) MBN 50112-1:2023-06 (12.6.6.1; 12.6.7.1; 12.6.7.2; 12.6.8.1; 12.6.8.2) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Badania starzeniowe:\nZakres:\ndługotrwałe starzenie kabla (3000 h)\nkrótkotrwałe starzenie kabla (240 h)\nprzeciążenie cieplne kabli\nstarzenie krótkotrwałe PVC\nPiec do 200 °C (± 2 °C)\nKomora klimatyczna: - 40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. VW 75205:2019-11 (p. 11.5.1.1; 11.5.1.2) VW 75205:2023-05 (p. 11.5.1.1; 11.5.1.2) VW 75205:2024-04 (p. 11.6.1.1; 11.6.1.2) VW 75209-1:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) VW 75209-1:2021-12 (p. 9.7.5; 9.7.5.2; 9.7.4; 9.7.6; 9.7.6.2) VW 75209-2:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) VW 75209-2:2021-12 (p.9.7.4; 9.7.5.2; 9.7.3; 9.7.6; 9.7.6.2; 9.7.5) VW 75210-1:2023-06 (p. 9.7.6; 9.7.6.1; 9.7.6.2; 9.7.7; 9.7.8; 9.7.8.1) VW 75210-1:2024-08 (p. 9.7.6, 9.7.6.1; 9.7.6.2; 9.7.7; 9.7.7.1; 9.7.8; 9.7.8.1) VW 75210-2:2023-06 (p. 9.7.5; 9.7.6; 9.7.7; 9.7.7.1) MBN LV 112-1:2016-03 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) MBN LV 122:2017-06 (p. 11.5.5; 11.5.5.2) MBN 50122:2023-07 (p. 13.5.5; 13.5.5.2) MBN LV 212-1:2017-08 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) MBN 50212-1:2023-04 (p. 12.7.5; 12.7.6; 12.7.6.1; 12.7.6.2; 12.7.7; 12.7.7.1; 12.7.7.2) MBN LV 216-2:2017-07 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) GS 95007-1-1:2013-05 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) GS 95007-1-2:2013-05 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) GS 95007-1-5:2015-07 (p. 11.5.1.1; 11.5.1.2) GS 95007-3-1:2015-08 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) GS 95007-3-2:2015-09 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) GS 95007-6-1:2016-03 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) GS 95007-6-2:2017-04 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) MBN 50112-1:2023-06 (12.6.6.1; 12.6.7.1; 12.6.7.2; 12.6.8.1; 12.6.8.2) Scope of accreditation No. AB 1776 Kable, Cables Badania starzeniowe:\nZakres:\ndlugotrwale starzenie kabla (3000 h)\nkrotkotrwale starzenie kabla (240 h)\nprzeciazenie cieplne kabli\nstarzenie krotkotrwale PVC\nPiec do 200 °C (± 2 °C)\nKomora klimatyczna: - 40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. VW 75205:2019-11 (p. 11.5.1.1; 11.5.1.2) VW 75205:2023-05 (p. 11.5.1.1; 11.5.1.2) VW 75205:2024-04 (p. 11.6.1.1; 11.6.1.2) VW 75209-1:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) VW 75209-1:2021-12 (p. 9.7.5; 9.7.5.2; 9.7.4; 9.7.6; 9.7.6.2) VW 75209-2:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) VW 75209-2:2021-12 (p.9.7.4; 9.7.5.2; 9.7.3; 9.7.6; 9.7.6.2; 9.7.5) VW 75210-1:2023-06 (p. 9.7.6; 9.7.6.1; 9.7.6.2; 9.7.7; 9.7.8; 9.7.8.1) VW 75210-1:2024-08 (p. 9.7.6, 9.7.6.1; 9.7.6.2; 9.7.7; 9.7.7.1; 9.7.8; 9.7.8.1) VW 75210-2:2023-06 (p. 9.7.5; 9.7.6; 9.7.7; 9.7.7.1) MBN LV 112-1:2016-03 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) MBN LV 122:2017-06 (p. 11.5.5; 11.5.5.2) MBN 50122:2023-07 (p. 13.5.5; 13.5.5.2) MBN LV 212-1:2017-08 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) MBN 50212-1:2023-04 (p. 12.7.5; 12.7.6; 12.7.6.1; 12.7.6.2; 12.7.7; 12.7.7.1; 12.7.7.2) MBN LV 216-2:2017-07 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) GS 95007-1-1:2013-05 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) GS 95007-1-2:2013-05 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) GS 95007-1-5:2015-07 (p. 11.5.1.1; 11.5.1.2) GS 95007-3-1:2015-08 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) GS 95007-3-2:2015-09 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) GS 95007-6-1:2016-03 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) GS 95007-6-2:2017-04 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) MBN 50112-1:2023-06 (12.6.6.1; 12.6.7.1; 12.6.7.2; 12.6.8.1; 12.6.8.2) Scope of accreditation No. AB 1776","categories":["other"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Ageing tests: long-term cable ageing short-term cable ageing thermal overload of cables short-term ageing of PVC Stove Climatic chamber: - 40 °C Range 0,5 kV to 6 kV D.C. VW 75205:2019-11 (p. 11.5.1.1; 11.5.1.2) VW 75205:2023-05 (p. 11.5.1.1; 11.5.1.2) VW 75205:2024-04 (p. 11.6.1.1; 11.6.1.2) VW 75209-1:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) VW 75209-1:2021-12 (p. 9.7.5; 9.7.5.2; 9.7.4; 9.7.6; 9.7.6.2) VW 75209-2:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) VW 75209-2:2021-12 (p.9.7.4; 9.7.5.2; 9.7.3; 9.7.6; 9.7.6.2; 9.7.5) VW 75210-1:2023-06 (p. 9.7.6; 9.7.6.1; 9.7.6.2; 9.7.7; 9.7.8; 9.7.8.1) VW 75210-1:2024-08 (p. 9.7.6, 9.7.6.1; 9.7.6.2; 9.7.7; 9.7.7.1; 9.7.8; 9.7.8.1) VW 75210-2:2023-06 (p. 9.7.5; 9.7.6; 9.7.7; 9.7.7.1) MBN LV 112-1:2016-03 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) MBN LV 122:2017-06 (p. 11.5.5; 11.5.5.2) MBN 50122:2023-07 (p. 13.5.5; 13.5.5.2) MBN LV 212-1:2017-08 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) MBN 50212-1:2023-04 (p. 12.7.5; 12.7.6; 12.7.6.1; 12.7.6.2; 12.7.7; 12.7.7.1; 12.7.7.2) MBN LV 216-2:2017-07 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) GS 95007-1-1:2013-05 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) GS 95007-1-2:2013-05 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) GS 95007-1-5:2015-07 (p. 11.5.1.1; 11.5.1.2) GS 95007-3-1:2015-08 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) GS 95007-3-2:2015-09 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) GS 95007-6-1:2016-03 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) GS 95007-6-2:2017-04 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) MBN 50112-1:2023-06 (12.6.6.1; 12.6.7.1; 12.6.7.2; 12.6.8.1; 12.6.8.2) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"电缆长期老化","range":"(3000 h)"},{"name":"电缆短期老化","range":"(240 h)"},{"name":"电缆热过载"},{"name":"starzenie krótkotrwałe PVC"},{"name":"炉窑","range":"do 200 °C (± 2 °C)"},{"name":"气候试验箱：- 40 °C","range":"do 125 °C"},{"name":"范围","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV do 6 kV D.C."}],"search_zh":"电缆 老化检验： 电缆长期老化 电缆短期老化 电缆热过载 炉窑 气候试验箱：- 40 °C 范围 VW 75205:2019-11 (p. 11.5.1.1; 11.5.1.2) VW 75205:2023-05 (p. 11.5.1.1; 11.5.1.2) VW 75205:2024-04 (p. 11.6.1.1; 11.6.1.2) VW 75209-1:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) VW 75209-1:2021-12 (p. 9.7.5; 9.7.5.2; 9.7.4; 9.7.6; 9.7.6.2) VW 75209-2:2015-01 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) VW 75209-2:2021-12 (p.9.7.4; 9.7.5.2; 9.7.3; 9.7.6; 9.7.6.2; 9.7.5) VW 75210-1:2023-06 (p. 9.7.6; 9.7.6.1; 9.7.6.2; 9.7.7; 9.7.8; 9.7.8.1) VW 75210-1:2024-08 (p. 9.7.6, 9.7.6.1; 9.7.6.2; 9.7.7; 9.7.7.1; 9.7.8; 9.7.8.1) VW 75210-2:2023-06 (p. 9.7.5; 9.7.6; 9.7.7; 9.7.7.1) MBN LV 112-1:2016-03 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) MBN LV 122:2017-06 (p. 11.5.5; 11.5.5.2) MBN 50122:2023-07 (p. 13.5.5; 13.5.5.2) MBN LV 212-1:2017-08 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) MBN 50212-1:2023-04 (p. 12.7.5; 12.7.6; 12.7.6.1; 12.7.6.2; 12.7.7; 12.7.7.1; 12.7.7.2) MBN LV 216-2:2017-07 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) GS 95007-1-1:2013-05 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) GS 95007-1-2:2013-05 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) GS 95007-1-5:2015-07 (p. 11.5.1.1; 11.5.1.2) GS 95007-3-1:2015-08 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) GS 95007-3-2:2015-09 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) GS 95007-6-1:2016-03 (p. 9.6.7; 9.6.7.1; 9.6.6.1; 9.6.8; 9.6.8.1) GS 95007-6-2:2017-04 (p. 9.6.6; 9.6.6.1; 9.6.5; 9.6.7; 9.6.7.1) MBN 50112-1:2023-06 (12.6.6.1; 12.6.7.1; 12.6.7.2; 12.6.8.1; 12.6.8.2) Scope of accreditation No. AB 1776","test_object_zh":"电缆","methodology_zh":"老化检验："},{"_id":"6a5dc9a9f1c10c8ce8259ed3","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"","methodology_en":null,"parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"","reference":"MBN 50112-2:2023-05 (p. 12.7.5; 12.7.6; 12.7.7) MBN 50216-1:2023-07 (p. 12.7.5; 12.7.5.2; 12.7.6; 12.7.6.1; 12.7.6.2; 12.7.7; 12.7.7.1) MBN 50112-4:2024-06 (p. 12.6; 12.6.7.1; 12.6.8.1)","norm_bases":["MBN 50112-2:2023-05 (p. 12.7.5; 12.7.6; 12.7.7) MBN 50216-1:2023-07 (p. 12.7.5; 12.7.5.2; 12.7.6; 12.7.6.1; 12.7.6.2; 12.7.7; 12.7.7.1) MBN 50112-4:2024-06 (p. 12.6; 12.6.7.1; 12.6.8.1)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables MBN 50112-2:2023-05 (p. 12.7.5; 12.7.6; 12.7.7) MBN 50216-1:2023-07 (p. 12.7.5; 12.7.5.2; 12.7.6; 12.7.6.1; 12.7.6.2; 12.7.7; 12.7.7.1) MBN 50112-4:2024-06 (p. 12.6; 12.6.7.1; 12.6.8.1) Kable, Cables MBN 50112-2:2023-05 (p. 12.7.5; 12.7.6; 12.7.7) MBN 50216-1:2023-07 (p. 12.7.5; 12.7.5.2; 12.7.6; 12.7.6.1; 12.7.6.2; 12.7.7; 12.7.7.1) MBN 50112-4:2024-06 (p. 12.6; 12.6.7.1; 12.6.8.1)","categories":["other"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables MBN 50112-2:2023-05 (p. 12.7.5; 12.7.6; 12.7.7) MBN 50216-1:2023-07 (p. 12.7.5; 12.7.5.2; 12.7.6; 12.7.6.1; 12.7.6.2; 12.7.7; 12.7.7.1) MBN 50112-4:2024-06 (p. 12.6; 12.6.7.1; 12.6.8.1)","search_zh":"电缆 MBN 50112-2:2023-05 (p. 12.7.5; 12.7.6; 12.7.7) MBN 50216-1:2023-07 (p. 12.7.5; 12.7.5.2; 12.7.6; 12.7.6.1; 12.7.6.2; 12.7.7; 12.7.7.1) MBN 50112-4:2024-06 (p. 12.6; 12.6.7.1; 12.6.8.1)","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ed4","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Odporność izolacji / powłoki kabla na nacisk w wysokiej temperaturze","methodology_en":"Resistance of cable insulation / sheath to pressure at high temperature","parameters":[{"name":"Piec","range":"do 200°C (± 2°C)"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV do 6 kV D.C."}],"parameters_en":[{"name":"Stove","range":"do 200°C (± 2°C)"},{"name":"Range","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność izolacji / powłoki kabla na nacisk w wysokiej temperaturze\nZakres:\nPiec do 200°C (± 2°C)\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C.","reference":"IEC 60811-508:2012 (p. 4.4) | IEC 60811-508:2012-03/AMD1:2017-07 (p. 4.4.1) | IEC 60811-508:2012-03/AMD2:2023-11 (p. 4.4) | ISO 19642-2:2019-01 (p. 5.4.5; 6.4.5) | ISO 19642-2:2023 (p. 5.5.5; 6.5.5) | ISO 19642-3:2019-01 (p. 5.5.5) | ISO 19642-4:2019-01 (p. 5.5.5) | ISO 19642-5:2019-01 (p. 5.5.5) | ISO 19642-6:2019-01 (p. 5.5.5) | ISO 19642-7:2019-01 (p. 6.5.5) | ISO 19642-8:2019-01 (p. 6.5.5) | ISO 19642-9:2019-01 (p. 6.5.5) | ISO 19642-10:2019-01 (p. 6.5.5) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.8) | ISO 6722-2:2013-12-01 (p. 5.8) | ISO 14572:2011-10 (p. 5.7) LV 112-1:2013-04 (p. 9.6.3) LV 112-1:2014-04 (p. 9.6.3) LV 112-2:2007-11 (p. 8.7.3) LV 112-2:2013-04 (p. 9.6.3) LV 212-1:2015-01 (p. 9.6.3) LV 212-2:2015-01 (p. 9.6.3) LV 216-1:2015-07 (p. 9.6.3) LV 216-2:2017-02 (p. 9.6.3) VW 60306-1:2018-09-01 (p. 9.6.3) VW 60306-1:2021-10 (p. 9.7.3) VW 60306-2:2013-04 (p. 9.6.3) VW 60306-2:2021-11 (p. 9.7.3) VW 60306-4:2021-12 (p. 9.7.3) VW 75209-1:2015-01 (p. 9.6.3) VW 75209-1:2021-12 (p. 9.7.2) VW 75209-2:2015-01 (p. 9.6.3) VW 75209-2:2021-12 (p. 9.7.1) VW 75210-1:2023-06 (p. 9.7.3) VW 75210-1:2024-08 (p. 9.7.3) VW 75210-2:2023-06 (p. 9.7.3) MBN LV 112-1:2016-03 (p. 9.6.3) MBN 50112-1:2023-06 (p. 12.6.3) MBN LV 112-2:2012-01 (p. 8.7.3) MBN 50112-2:2023-05 (p. 12.7.3) MBN 50216-1:2023-07 (p. 12.7.3) MBN LV 212-1:2017-08 (p. 9.6.3) MBN 50212-1:2023-04 (p. 12.7.3) MBN LV 216-2:2017-07 (p. 9.6.3) MBN 50112-4:2024-06 (p. 12.6.3) Scope of accreditation No. AB 1776","norm_bases":["IEC 60811-508:2012 (p. 4.4)","IEC 60811-508:2012-03/AMD1:2017-07 (p. 4.4.1)","IEC 60811-508:2012-03/AMD2:2023-11 (p. 4.4)","ISO 19642-2:2019-01 (p. 5.4.5; 6.4.5)","ISO 19642-2:2023 (p. 5.5.5; 6.5.5)","ISO 19642-3:2019-01 (p. 5.5.5)","ISO 19642-4:2019-01 (p. 5.5.5)","ISO 19642-5:2019-01 (p. 5.5.5)","ISO 19642-6:2019-01 (p. 5.5.5)","ISO 19642-7:2019-01 (p. 6.5.5)","ISO 19642-8:2019-01 (p. 6.5.5)","ISO 19642-9:2019-01 (p. 6.5.5)","ISO 19642-10:2019-01 (p. 6.5.5)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.8)","ISO 6722-2:2013-12-01 (p. 5.8)","ISO 14572:2011-10 (p. 5.7) LV 112-1:2013-04 (p. 9.6.3) LV 112-1:2014-04 (p. 9.6.3) LV 112-2:2007-11 (p. 8.7.3) LV 112-2:2013-04 (p. 9.6.3) LV 212-1:2015-01 (p. 9.6.3) LV 212-2:2015-01 (p. 9.6.3) LV 216-1:2015-07 (p. 9.6.3) LV 216-2:2017-02 (p. 9.6.3) VW 60306-1:2018-09-01 (p. 9.6.3) VW 60306-1:2021-10 (p. 9.7.3) VW 60306-2:2013-04 (p. 9.6.3) VW 60306-2:2021-11 (p. 9.7.3) VW 60306-4:2021-12 (p. 9.7.3) VW 75209-1:2015-01 (p. 9.6.3) VW 75209-1:2021-12 (p. 9.7.2) VW 75209-2:2015-01 (p. 9.6.3) VW 75209-2:2021-12 (p. 9.7.1) VW 75210-1:2023-06 (p. 9.7.3) VW 75210-1:2024-08 (p. 9.7.3) VW 75210-2:2023-06 (p. 9.7.3) MBN LV 112-1:2016-03 (p. 9.6.3) MBN 50112-1:2023-06 (p. 12.6.3) MBN LV 112-2:2012-01 (p. 8.7.3) MBN 50112-2:2023-05 (p. 12.7.3) MBN 50216-1:2023-07 (p. 12.7.3) MBN LV 212-1:2017-08 (p. 9.6.3) MBN 50212-1:2023-04 (p. 12.7.3) MBN LV 216-2:2017-07 (p. 9.6.3) MBN 50112-4:2024-06 (p. 12.6.3) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Odporność izolacji / powłoki kabla na nacisk w wysokiej temperaturze\nZakres:\nPiec do 200°C (± 2°C)\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. IEC 60811-508:2012 (p. 4.4) | IEC 60811-508:2012-03/AMD1:2017-07 (p. 4.4.1) | IEC 60811-508:2012-03/AMD2:2023-11 (p. 4.4) | ISO 19642-2:2019-01 (p. 5.4.5; 6.4.5) | ISO 19642-2:2023 (p. 5.5.5; 6.5.5) | ISO 19642-3:2019-01 (p. 5.5.5) | ISO 19642-4:2019-01 (p. 5.5.5) | ISO 19642-5:2019-01 (p. 5.5.5) | ISO 19642-6:2019-01 (p. 5.5.5) | ISO 19642-7:2019-01 (p. 6.5.5) | ISO 19642-8:2019-01 (p. 6.5.5) | ISO 19642-9:2019-01 (p. 6.5.5) | ISO 19642-10:2019-01 (p. 6.5.5) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.8) | ISO 6722-2:2013-12-01 (p. 5.8) | ISO 14572:2011-10 (p. 5.7) LV 112-1:2013-04 (p. 9.6.3) LV 112-1:2014-04 (p. 9.6.3) LV 112-2:2007-11 (p. 8.7.3) LV 112-2:2013-04 (p. 9.6.3) LV 212-1:2015-01 (p. 9.6.3) LV 212-2:2015-01 (p. 9.6.3) LV 216-1:2015-07 (p. 9.6.3) LV 216-2:2017-02 (p. 9.6.3) VW 60306-1:2018-09-01 (p. 9.6.3) VW 60306-1:2021-10 (p. 9.7.3) VW 60306-2:2013-04 (p. 9.6.3) VW 60306-2:2021-11 (p. 9.7.3) VW 60306-4:2021-12 (p. 9.7.3) VW 75209-1:2015-01 (p. 9.6.3) VW 75209-1:2021-12 (p. 9.7.2) VW 75209-2:2015-01 (p. 9.6.3) VW 75209-2:2021-12 (p. 9.7.1) VW 75210-1:2023-06 (p. 9.7.3) VW 75210-1:2024-08 (p. 9.7.3) VW 75210-2:2023-06 (p. 9.7.3) MBN LV 112-1:2016-03 (p. 9.6.3) MBN 50112-1:2023-06 (p. 12.6.3) MBN LV 112-2:2012-01 (p. 8.7.3) MBN 50112-2:2023-05 (p. 12.7.3) MBN 50216-1:2023-07 (p. 12.7.3) MBN LV 212-1:2017-08 (p. 9.6.3) MBN 50212-1:2023-04 (p. 12.7.3) MBN LV 216-2:2017-07 (p. 9.6.3) MBN 50112-4:2024-06 (p. 12.6.3) Scope of accreditation No. AB 1776 Kable, Cables Odpornosc izolacji / powloki kabla na nacisk w wysokiej temperaturze\nZakres:\nPiec do 200°C (± 2°C)\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. IEC 60811-508:2012 (p. 4.4) | IEC 60811-508:2012-03/AMD1:2017-07 (p. 4.4.1) | IEC 60811-508:2012-03/AMD2:2023-11 (p. 4.4) | ISO 19642-2:2019-01 (p. 5.4.5; 6.4.5) | ISO 19642-2:2023 (p. 5.5.5; 6.5.5) | ISO 19642-3:2019-01 (p. 5.5.5) | ISO 19642-4:2019-01 (p. 5.5.5) | ISO 19642-5:2019-01 (p. 5.5.5) | ISO 19642-6:2019-01 (p. 5.5.5) | ISO 19642-7:2019-01 (p. 6.5.5) | ISO 19642-8:2019-01 (p. 6.5.5) | ISO 19642-9:2019-01 (p. 6.5.5) | ISO 19642-10:2019-01 (p. 6.5.5) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.8) | ISO 6722-2:2013-12-01 (p. 5.8) | ISO 14572:2011-10 (p. 5.7) LV 112-1:2013-04 (p. 9.6.3) LV 112-1:2014-04 (p. 9.6.3) LV 112-2:2007-11 (p. 8.7.3) LV 112-2:2013-04 (p. 9.6.3) LV 212-1:2015-01 (p. 9.6.3) LV 212-2:2015-01 (p. 9.6.3) LV 216-1:2015-07 (p. 9.6.3) LV 216-2:2017-02 (p. 9.6.3) VW 60306-1:2018-09-01 (p. 9.6.3) VW 60306-1:2021-10 (p. 9.7.3) VW 60306-2:2013-04 (p. 9.6.3) VW 60306-2:2021-11 (p. 9.7.3) VW 60306-4:2021-12 (p. 9.7.3) VW 75209-1:2015-01 (p. 9.6.3) VW 75209-1:2021-12 (p. 9.7.2) VW 75209-2:2015-01 (p. 9.6.3) VW 75209-2:2021-12 (p. 9.7.1) VW 75210-1:2023-06 (p. 9.7.3) VW 75210-1:2024-08 (p. 9.7.3) VW 75210-2:2023-06 (p. 9.7.3) MBN LV 112-1:2016-03 (p. 9.6.3) MBN 50112-1:2023-06 (p. 12.6.3) MBN LV 112-2:2012-01 (p. 8.7.3) MBN 50112-2:2023-05 (p. 12.7.3) MBN 50216-1:2023-07 (p. 12.7.3) MBN LV 212-1:2017-08 (p. 9.6.3) MBN 50212-1:2023-04 (p. 12.7.3) MBN LV 216-2:2017-07 (p. 9.6.3) MBN 50112-4:2024-06 (p. 12.6.3) Scope of accreditation No. AB 1776","categories":["construction"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Resistance of cable insulation / sheath to pressure at high temperature Stove Range 0,5 kV to 6 kV D.C. IEC 60811-508:2012 (p. 4.4) | IEC 60811-508:2012-03/AMD1:2017-07 (p. 4.4.1) | IEC 60811-508:2012-03/AMD2:2023-11 (p. 4.4) | ISO 19642-2:2019-01 (p. 5.4.5; 6.4.5) | ISO 19642-2:2023 (p. 5.5.5; 6.5.5) | ISO 19642-3:2019-01 (p. 5.5.5) | ISO 19642-4:2019-01 (p. 5.5.5) | ISO 19642-5:2019-01 (p. 5.5.5) | ISO 19642-6:2019-01 (p. 5.5.5) | ISO 19642-7:2019-01 (p. 6.5.5) | ISO 19642-8:2019-01 (p. 6.5.5) | ISO 19642-9:2019-01 (p. 6.5.5) | ISO 19642-10:2019-01 (p. 6.5.5) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.8) | ISO 6722-2:2013-12-01 (p. 5.8) | ISO 14572:2011-10 (p. 5.7) LV 112-1:2013-04 (p. 9.6.3) LV 112-1:2014-04 (p. 9.6.3) LV 112-2:2007-11 (p. 8.7.3) LV 112-2:2013-04 (p. 9.6.3) LV 212-1:2015-01 (p. 9.6.3) LV 212-2:2015-01 (p. 9.6.3) LV 216-1:2015-07 (p. 9.6.3) LV 216-2:2017-02 (p. 9.6.3) VW 60306-1:2018-09-01 (p. 9.6.3) VW 60306-1:2021-10 (p. 9.7.3) VW 60306-2:2013-04 (p. 9.6.3) VW 60306-2:2021-11 (p. 9.7.3) VW 60306-4:2021-12 (p. 9.7.3) VW 75209-1:2015-01 (p. 9.6.3) VW 75209-1:2021-12 (p. 9.7.2) VW 75209-2:2015-01 (p. 9.6.3) VW 75209-2:2021-12 (p. 9.7.1) VW 75210-1:2023-06 (p. 9.7.3) VW 75210-1:2024-08 (p. 9.7.3) VW 75210-2:2023-06 (p. 9.7.3) MBN LV 112-1:2016-03 (p. 9.6.3) MBN 50112-1:2023-06 (p. 12.6.3) MBN LV 112-2:2012-01 (p. 8.7.3) MBN 50112-2:2023-05 (p. 12.7.3) MBN 50216-1:2023-07 (p. 12.7.3) MBN LV 212-1:2017-08 (p. 9.6.3) MBN 50212-1:2023-04 (p. 12.7.3) MBN LV 216-2:2017-07 (p. 9.6.3) MBN 50112-4:2024-06 (p. 12.6.3) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"炉窑","range":"do 200°C (± 2°C)"},{"name":"范围","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV do 6 kV D.C."}],"search_zh":"电缆 炉窑 范围 IEC 60811-508:2012 (p. 4.4) | IEC 60811-508:2012-03/AMD1:2017-07 (p. 4.4.1) | IEC 60811-508:2012-03/AMD2:2023-11 (p. 4.4) | ISO 19642-2:2019-01 (p. 5.4.5; 6.4.5) | ISO 19642-2:2023 (p. 5.5.5; 6.5.5) | ISO 19642-3:2019-01 (p. 5.5.5) | ISO 19642-4:2019-01 (p. 5.5.5) | ISO 19642-5:2019-01 (p. 5.5.5) | ISO 19642-6:2019-01 (p. 5.5.5) | ISO 19642-7:2019-01 (p. 6.5.5) | ISO 19642-8:2019-01 (p. 6.5.5) | ISO 19642-9:2019-01 (p. 6.5.5) | ISO 19642-10:2019-01 (p. 6.5.5) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.8) | ISO 6722-2:2013-12-01 (p. 5.8) | ISO 14572:2011-10 (p. 5.7) LV 112-1:2013-04 (p. 9.6.3) LV 112-1:2014-04 (p. 9.6.3) LV 112-2:2007-11 (p. 8.7.3) LV 112-2:2013-04 (p. 9.6.3) LV 212-1:2015-01 (p. 9.6.3) LV 212-2:2015-01 (p. 9.6.3) LV 216-1:2015-07 (p. 9.6.3) LV 216-2:2017-02 (p. 9.6.3) VW 60306-1:2018-09-01 (p. 9.6.3) VW 60306-1:2021-10 (p. 9.7.3) VW 60306-2:2013-04 (p. 9.6.3) VW 60306-2:2021-11 (p. 9.7.3) VW 60306-4:2021-12 (p. 9.7.3) VW 75209-1:2015-01 (p. 9.6.3) VW 75209-1:2021-12 (p. 9.7.2) VW 75209-2:2015-01 (p. 9.6.3) VW 75209-2:2021-12 (p. 9.7.1) VW 75210-1:2023-06 (p. 9.7.3) VW 75210-1:2024-08 (p. 9.7.3) VW 75210-2:2023-06 (p. 9.7.3) MBN LV 112-1:2016-03 (p. 9.6.3) MBN 50112-1:2023-06 (p. 12.6.3) MBN LV 112-2:2012-01 (p. 8.7.3) MBN 50112-2:2023-05 (p. 12.7.3) MBN 50216-1:2023-07 (p. 12.7.3) MBN LV 212-1:2017-08 (p. 9.6.3) MBN 50212-1:2023-04 (p. 12.7.3) MBN LV 216-2:2017-07 (p. 9.6.3) MBN 50112-4:2024-06 (p. 12.6.3) Scope of accreditation No. AB 1776","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ed5","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"","methodology_en":null,"parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"","reference":"GS 95007-1-1:2013-05 (p. 9.6.3) GS 95007-1-2:2013-05 (p. 9.6.3) GS 95007-3-1:2015-08 (p. 9.6.3) GS 95007-3-2:2015-09 (p. 9.6.3) GS 95007-6-1:2016-03 (p. 9.6.3) GS 95007-6-2:2017-04 (p. 9.6.3)","norm_bases":["GS 95007-1-1:2013-05 (p. 9.6.3) GS 95007-1-2:2013-05 (p. 9.6.3) GS 95007-3-1:2015-08 (p. 9.6.3) GS 95007-3-2:2015-09 (p. 9.6.3) GS 95007-6-1:2016-03 (p. 9.6.3) GS 95007-6-2:2017-04 (p. 9.6.3)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables GS 95007-1-1:2013-05 (p. 9.6.3) GS 95007-1-2:2013-05 (p. 9.6.3) GS 95007-3-1:2015-08 (p. 9.6.3) GS 95007-3-2:2015-09 (p. 9.6.3) GS 95007-6-1:2016-03 (p. 9.6.3) GS 95007-6-2:2017-04 (p. 9.6.3) Kable, Cables GS 95007-1-1:2013-05 (p. 9.6.3) GS 95007-1-2:2013-05 (p. 9.6.3) GS 95007-3-1:2015-08 (p. 9.6.3) GS 95007-3-2:2015-09 (p. 9.6.3) GS 95007-6-1:2016-03 (p. 9.6.3) GS 95007-6-2:2017-04 (p. 9.6.3)","categories":["other"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables GS 95007-1-1:2013-05 (p. 9.6.3) GS 95007-1-2:2013-05 (p. 9.6.3) GS 95007-3-1:2015-08 (p. 9.6.3) GS 95007-3-2:2015-09 (p. 9.6.3) GS 95007-6-1:2016-03 (p. 9.6.3) GS 95007-6-2:2017-04 (p. 9.6.3)","search_zh":"电缆 GS 95007-1-1:2013-05 (p. 9.6.3) GS 95007-1-2:2013-05 (p. 9.6.3) GS 95007-3-1:2015-08 (p. 9.6.3) GS 95007-3-2:2015-09 (p. 9.6.3) GS 95007-6-1:2016-03 (p. 9.6.3) GS 95007-6-2:2017-04 (p. 9.6.3)","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ed6","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Skurcz izolacji / powłoki kabla pod wpływem ciepła","methodology_en":"Heat shrinkage of the cable insulation / sheath","parameters":[{"name":"Piec","range":"do 200°C (± 2°C)"},{"name":"Cable insulation / sheath shrinkage"}],"parameters_en":[{"name":"Stove","range":"do 200°C (± 2°C)"},{"name":"Cable insulation / sheath shrinkage"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Skurcz izolacji / powłoki kabla pod wpływem ciepła\nZakres:\nPiec do 200°C (± 2°C)\nCable insulation / sheath shrinkage","reference":"ISO 19642-2:2019-01 (p. 5.4.6; 6.4.6) | ISO 19642-2:2023 (p. 5.5.6; 6.5.6) | ISO 19642-3:2019-01 (p. 5.5.6) | ISO 19642-4:2019-01 (p. 5.5.6) | ISO 19642-5:2019-01 (p. 5.5.6) | ISO 19642-6:2019-01 (p. 5.5.6) | ISO 19642-7:2019-01 (p. 6.5.6) | ISO 19642-8:2019-01 (p. 6.5.6) | ISO 19642-9:2019-01 (p. 6.5.6) | ISO 19642-10:2019-01 (p. 6.5.6) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.16) | ISO 6722-2:2013-12-01 (p. 5.16) | ISO 14572:2011-10 (p. 5.16) LV 112-1:2013-04 (p. 9.6.2) LV 112-1:2014-04 (p. 9.6.2) LV 112-2:2007-11 (p. 8.7.2) LV 112-2:2013-04 (p. 9.6.2) LV 212-1:2015-01 (p. 9.6.2) LV 212-2:2015-01 (p. 9.6.2) LV 216-1:2015-07 (p. 9.6.2) LV 216-2:2017-02 (p. 9.6.2) VW 60306-1:2018-09-01 (p. 9.6.2) VW 60306-1:2021-10 (p. 9.7.2) VW 60306-2:2013-04 (p. 9.6.2) VW 60306-2:2021-11 (p. 9.7.2) VW 60306-4:2021-12 (p. 9.7.2) VW 75209-1:2015-01 (p. 9.6.2) VW 75209-1:2021-12 (p. 9.7.1) VW 75209-2:2015-01 (p. 9.6.2) VW 75209-2:2021-12 (p. 9.7) VW 75210-1:2023-06 (p. 9.7.2) VW 75210-1:2024-08 (p. 9.7.2) VW 75210-2:2023-06 (p. 9.7.2) MBN LV 112-1:2016-03 (p. 9.6.2) MBN 50112-1:2023-06 (p. 12.6.2) MBN LV 112-2:2012-01 (p. 8.7.2) MBN 50112-2:2023-05 (p. 12.7.2) MBN 50216-1:2023-07 (p. 12.7.2) MBN LV 212-1:2017-08 (p. 9.6.2) MBN 50212-1:2023-04 (p. 12.7.2) MBN LV 216-2:2017-07 (p. 9.6.2) MBN 50112-4:2024-06 (p. 12.6.2) GS 95007-1-1:2013-05 (p. 9.6.2) GS 95007-1-2:2013-05 (p. 9.6.2) GS 95007-3-1:2015-08 (p. 9.6.2) GS 95007-3-2:2015-09 (p. 9.6.2) GS 95007-6-1:2016-03 (p. 9.6.2) GS 95007-6-2:2017-04 (p. 9.6.2) Scope of accreditation No. AB 1776","norm_bases":["ISO 19642-2:2019-01 (p. 5.4.6; 6.4.6)","ISO 19642-2:2023 (p. 5.5.6; 6.5.6)","ISO 19642-3:2019-01 (p. 5.5.6)","ISO 19642-4:2019-01 (p. 5.5.6)","ISO 19642-5:2019-01 (p. 5.5.6)","ISO 19642-6:2019-01 (p. 5.5.6)","ISO 19642-7:2019-01 (p. 6.5.6)","ISO 19642-8:2019-01 (p. 6.5.6)","ISO 19642-9:2019-01 (p. 6.5.6)","ISO 19642-10:2019-01 (p. 6.5.6)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.16)","ISO 6722-2:2013-12-01 (p. 5.16)","ISO 14572:2011-10 (p. 5.16) LV 112-1:2013-04 (p. 9.6.2) LV 112-1:2014-04 (p. 9.6.2) LV 112-2:2007-11 (p. 8.7.2) LV 112-2:2013-04 (p. 9.6.2) LV 212-1:2015-01 (p. 9.6.2) LV 212-2:2015-01 (p. 9.6.2) LV 216-1:2015-07 (p. 9.6.2) LV 216-2:2017-02 (p. 9.6.2) VW 60306-1:2018-09-01 (p. 9.6.2) VW 60306-1:2021-10 (p. 9.7.2) VW 60306-2:2013-04 (p. 9.6.2) VW 60306-2:2021-11 (p. 9.7.2) VW 60306-4:2021-12 (p. 9.7.2) VW 75209-1:2015-01 (p. 9.6.2) VW 75209-1:2021-12 (p. 9.7.1) VW 75209-2:2015-01 (p. 9.6.2) VW 75209-2:2021-12 (p. 9.7) VW 75210-1:2023-06 (p. 9.7.2) VW 75210-1:2024-08 (p. 9.7.2) VW 75210-2:2023-06 (p. 9.7.2) MBN LV 112-1:2016-03 (p. 9.6.2) MBN 50112-1:2023-06 (p. 12.6.2) MBN LV 112-2:2012-01 (p. 8.7.2) MBN 50112-2:2023-05 (p. 12.7.2) MBN 50216-1:2023-07 (p. 12.7.2) MBN LV 212-1:2017-08 (p. 9.6.2) MBN 50212-1:2023-04 (p. 12.7.2) MBN LV 216-2:2017-07 (p. 9.6.2) MBN 50112-4:2024-06 (p. 12.6.2) GS 95007-1-1:2013-05 (p. 9.6.2) GS 95007-1-2:2013-05 (p. 9.6.2) GS 95007-3-1:2015-08 (p. 9.6.2) GS 95007-3-2:2015-09 (p. 9.6.2) GS 95007-6-1:2016-03 (p. 9.6.2) GS 95007-6-2:2017-04 (p. 9.6.2) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Skurcz izolacji / powłoki kabla pod wpływem ciepła\nZakres:\nPiec do 200°C (± 2°C)\nCable insulation / sheath shrinkage ISO 19642-2:2019-01 (p. 5.4.6; 6.4.6) | ISO 19642-2:2023 (p. 5.5.6; 6.5.6) | ISO 19642-3:2019-01 (p. 5.5.6) | ISO 19642-4:2019-01 (p. 5.5.6) | ISO 19642-5:2019-01 (p. 5.5.6) | ISO 19642-6:2019-01 (p. 5.5.6) | ISO 19642-7:2019-01 (p. 6.5.6) | ISO 19642-8:2019-01 (p. 6.5.6) | ISO 19642-9:2019-01 (p. 6.5.6) | ISO 19642-10:2019-01 (p. 6.5.6) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.16) | ISO 6722-2:2013-12-01 (p. 5.16) | ISO 14572:2011-10 (p. 5.16) LV 112-1:2013-04 (p. 9.6.2) LV 112-1:2014-04 (p. 9.6.2) LV 112-2:2007-11 (p. 8.7.2) LV 112-2:2013-04 (p. 9.6.2) LV 212-1:2015-01 (p. 9.6.2) LV 212-2:2015-01 (p. 9.6.2) LV 216-1:2015-07 (p. 9.6.2) LV 216-2:2017-02 (p. 9.6.2) VW 60306-1:2018-09-01 (p. 9.6.2) VW 60306-1:2021-10 (p. 9.7.2) VW 60306-2:2013-04 (p. 9.6.2) VW 60306-2:2021-11 (p. 9.7.2) VW 60306-4:2021-12 (p. 9.7.2) VW 75209-1:2015-01 (p. 9.6.2) VW 75209-1:2021-12 (p. 9.7.1) VW 75209-2:2015-01 (p. 9.6.2) VW 75209-2:2021-12 (p. 9.7) VW 75210-1:2023-06 (p. 9.7.2) VW 75210-1:2024-08 (p. 9.7.2) VW 75210-2:2023-06 (p. 9.7.2) MBN LV 112-1:2016-03 (p. 9.6.2) MBN 50112-1:2023-06 (p. 12.6.2) MBN LV 112-2:2012-01 (p. 8.7.2) MBN 50112-2:2023-05 (p. 12.7.2) MBN 50216-1:2023-07 (p. 12.7.2) MBN LV 212-1:2017-08 (p. 9.6.2) MBN 50212-1:2023-04 (p. 12.7.2) MBN LV 216-2:2017-07 (p. 9.6.2) MBN 50112-4:2024-06 (p. 12.6.2) GS 95007-1-1:2013-05 (p. 9.6.2) GS 95007-1-2:2013-05 (p. 9.6.2) GS 95007-3-1:2015-08 (p. 9.6.2) GS 95007-3-2:2015-09 (p. 9.6.2) GS 95007-6-1:2016-03 (p. 9.6.2) GS 95007-6-2:2017-04 (p. 9.6.2) Scope of accreditation No. AB 1776 Kable, Cables Skurcz izolacji / powloki kabla pod wplywem ciepla\nZakres:\nPiec do 200°C (± 2°C)\nCable insulation / sheath shrinkage ISO 19642-2:2019-01 (p. 5.4.6; 6.4.6) | ISO 19642-2:2023 (p. 5.5.6; 6.5.6) | ISO 19642-3:2019-01 (p. 5.5.6) | ISO 19642-4:2019-01 (p. 5.5.6) | ISO 19642-5:2019-01 (p. 5.5.6) | ISO 19642-6:2019-01 (p. 5.5.6) | ISO 19642-7:2019-01 (p. 6.5.6) | ISO 19642-8:2019-01 (p. 6.5.6) | ISO 19642-9:2019-01 (p. 6.5.6) | ISO 19642-10:2019-01 (p. 6.5.6) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.16) | ISO 6722-2:2013-12-01 (p. 5.16) | ISO 14572:2011-10 (p. 5.16) LV 112-1:2013-04 (p. 9.6.2) LV 112-1:2014-04 (p. 9.6.2) LV 112-2:2007-11 (p. 8.7.2) LV 112-2:2013-04 (p. 9.6.2) LV 212-1:2015-01 (p. 9.6.2) LV 212-2:2015-01 (p. 9.6.2) LV 216-1:2015-07 (p. 9.6.2) LV 216-2:2017-02 (p. 9.6.2) VW 60306-1:2018-09-01 (p. 9.6.2) VW 60306-1:2021-10 (p. 9.7.2) VW 60306-2:2013-04 (p. 9.6.2) VW 60306-2:2021-11 (p. 9.7.2) VW 60306-4:2021-12 (p. 9.7.2) VW 75209-1:2015-01 (p. 9.6.2) VW 75209-1:2021-12 (p. 9.7.1) VW 75209-2:2015-01 (p. 9.6.2) VW 75209-2:2021-12 (p. 9.7) VW 75210-1:2023-06 (p. 9.7.2) VW 75210-1:2024-08 (p. 9.7.2) VW 75210-2:2023-06 (p. 9.7.2) MBN LV 112-1:2016-03 (p. 9.6.2) MBN 50112-1:2023-06 (p. 12.6.2) MBN LV 112-2:2012-01 (p. 8.7.2) MBN 50112-2:2023-05 (p. 12.7.2) MBN 50216-1:2023-07 (p. 12.7.2) MBN LV 212-1:2017-08 (p. 9.6.2) MBN 50212-1:2023-04 (p. 12.7.2) MBN LV 216-2:2017-07 (p. 9.6.2) MBN 50112-4:2024-06 (p. 12.6.2) GS 95007-1-1:2013-05 (p. 9.6.2) GS 95007-1-2:2013-05 (p. 9.6.2) GS 95007-3-1:2015-08 (p. 9.6.2) GS 95007-3-2:2015-09 (p. 9.6.2) GS 95007-6-1:2016-03 (p. 9.6.2) GS 95007-6-2:2017-04 (p. 9.6.2) Scope of accreditation No. AB 1776","categories":["construction"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Heat shrinkage of the cable insulation / sheath Stove Cable insulation / sheath shrinkage ISO 19642-2:2019-01 (p. 5.4.6; 6.4.6) | ISO 19642-2:2023 (p. 5.5.6; 6.5.6) | ISO 19642-3:2019-01 (p. 5.5.6) | ISO 19642-4:2019-01 (p. 5.5.6) | ISO 19642-5:2019-01 (p. 5.5.6) | ISO 19642-6:2019-01 (p. 5.5.6) | ISO 19642-7:2019-01 (p. 6.5.6) | ISO 19642-8:2019-01 (p. 6.5.6) | ISO 19642-9:2019-01 (p. 6.5.6) | ISO 19642-10:2019-01 (p. 6.5.6) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.16) | ISO 6722-2:2013-12-01 (p. 5.16) | ISO 14572:2011-10 (p. 5.16) LV 112-1:2013-04 (p. 9.6.2) LV 112-1:2014-04 (p. 9.6.2) LV 112-2:2007-11 (p. 8.7.2) LV 112-2:2013-04 (p. 9.6.2) LV 212-1:2015-01 (p. 9.6.2) LV 212-2:2015-01 (p. 9.6.2) LV 216-1:2015-07 (p. 9.6.2) LV 216-2:2017-02 (p. 9.6.2) VW 60306-1:2018-09-01 (p. 9.6.2) VW 60306-1:2021-10 (p. 9.7.2) VW 60306-2:2013-04 (p. 9.6.2) VW 60306-2:2021-11 (p. 9.7.2) VW 60306-4:2021-12 (p. 9.7.2) VW 75209-1:2015-01 (p. 9.6.2) VW 75209-1:2021-12 (p. 9.7.1) VW 75209-2:2015-01 (p. 9.6.2) VW 75209-2:2021-12 (p. 9.7) VW 75210-1:2023-06 (p. 9.7.2) VW 75210-1:2024-08 (p. 9.7.2) VW 75210-2:2023-06 (p. 9.7.2) MBN LV 112-1:2016-03 (p. 9.6.2) MBN 50112-1:2023-06 (p. 12.6.2) MBN LV 112-2:2012-01 (p. 8.7.2) MBN 50112-2:2023-05 (p. 12.7.2) MBN 50216-1:2023-07 (p. 12.7.2) MBN LV 212-1:2017-08 (p. 9.6.2) MBN 50212-1:2023-04 (p. 12.7.2) MBN LV 216-2:2017-07 (p. 9.6.2) MBN 50112-4:2024-06 (p. 12.6.2) GS 95007-1-1:2013-05 (p. 9.6.2) GS 95007-1-2:2013-05 (p. 9.6.2) GS 95007-3-1:2015-08 (p. 9.6.2) GS 95007-3-2:2015-09 (p. 9.6.2) GS 95007-6-1:2016-03 (p. 9.6.2) GS 95007-6-2:2017-04 (p. 9.6.2) Scope of accreditation No. AB 1776","search_zh":"电缆 炉窑 ISO 19642-2:2019-01 (p. 5.4.6; 6.4.6) | ISO 19642-2:2023 (p. 5.5.6; 6.5.6) | ISO 19642-3:2019-01 (p. 5.5.6) | ISO 19642-4:2019-01 (p. 5.5.6) | ISO 19642-5:2019-01 (p. 5.5.6) | ISO 19642-6:2019-01 (p. 5.5.6) | ISO 19642-7:2019-01 (p. 6.5.6) | ISO 19642-8:2019-01 (p. 6.5.6) | ISO 19642-9:2019-01 (p. 6.5.6) | ISO 19642-10:2019-01 (p. 6.5.6) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.16) | ISO 6722-2:2013-12-01 (p. 5.16) | ISO 14572:2011-10 (p. 5.16) LV 112-1:2013-04 (p. 9.6.2) LV 112-1:2014-04 (p. 9.6.2) LV 112-2:2007-11 (p. 8.7.2) LV 112-2:2013-04 (p. 9.6.2) LV 212-1:2015-01 (p. 9.6.2) LV 212-2:2015-01 (p. 9.6.2) LV 216-1:2015-07 (p. 9.6.2) LV 216-2:2017-02 (p. 9.6.2) VW 60306-1:2018-09-01 (p. 9.6.2) VW 60306-1:2021-10 (p. 9.7.2) VW 60306-2:2013-04 (p. 9.6.2) VW 60306-2:2021-11 (p. 9.7.2) VW 60306-4:2021-12 (p. 9.7.2) VW 75209-1:2015-01 (p. 9.6.2) VW 75209-1:2021-12 (p. 9.7.1) VW 75209-2:2015-01 (p. 9.6.2) VW 75209-2:2021-12 (p. 9.7) VW 75210-1:2023-06 (p. 9.7.2) VW 75210-1:2024-08 (p. 9.7.2) VW 75210-2:2023-06 (p. 9.7.2) MBN LV 112-1:2016-03 (p. 9.6.2) MBN 50112-1:2023-06 (p. 12.6.2) MBN LV 112-2:2012-01 (p. 8.7.2) MBN 50112-2:2023-05 (p. 12.7.2) MBN 50216-1:2023-07 (p. 12.7.2) MBN LV 212-1:2017-08 (p. 9.6.2) MBN 50212-1:2023-04 (p. 12.7.2) MBN LV 216-2:2017-07 (p. 9.6.2) MBN 50112-4:2024-06 (p. 12.6.2) GS 95007-1-1:2013-05 (p. 9.6.2) GS 95007-1-2:2013-05 (p. 9.6.2) GS 95007-3-1:2015-08 (p. 9.6.2) GS 95007-3-2:2015-09 (p. 9.6.2) GS 95007-6-1:2016-03 (p. 9.6.2) GS 95007-6-2:2017-04 (p. 9.6.2) Scope of accreditation No. AB 1776","test_object_zh":"电缆","parameters_zh":[{"name":"炉窑","range":"do 200°C (± 2°C)"},{"name":"Cable insulation / sheath shrinkage"}]},{"_id":"6a5dc9a9f1c10c8ce8259ed7","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Nawijanie kabla w niskiej temperaturze","methodology_en":"Cable winding at low temperature","parameters":[{"name":"Komora klimatyczna","range":"-40 °C do 125 °C"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV do 6 kV D.C."}],"parameters_en":[{"name":"Climatic chamber","range":"-40 °C do 125 °C"},{"name":"Range","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Nawijanie kabla w niskiej temperaturze\nZakres:\nKomora klimatyczna -40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C.","reference":"ISO 19642-2:2019-01 (p. 5.4.7; 6.4.7) | ISO 19642-2:2023 (p. 5.5.7; 6.5.7) | ISO 19642-3:2019-01 (p. 5.5.7) | ISO 19642-4:2019-01 (p. 5.5.7) | ISO 19642-5:2019-01 (p. 5.5.7) | ISO 19642-6:2019-01 (p. 5.5.7) | ISO 19642-7:2019-01 (p. 6.5.7) | ISO 19642-8:2019-01 (p. 6.5.7) | ISO 19642-9:2019-01 (p. 6.5.7) | ISO 19642-10:2019-01 (p. 6.5.7) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.10) | ISO 6722-2:2013-12-01 (p. 5.10) | ISO 14572:2011-10 (p. 5.10) LV 112-1:2013-04 (p. 9.6.9) LV 112-1:2014-04 (p. 9.6.9) LV 112-2:2007-11 (p. 8.7.8) LV 112-2:2013-04 (p. 9.6.9) LV 122:2015-05 (p. 11.5.2) LV 122:2016-02 (p. 11.5.6) LV 212-1:2015-01 (p. 9.6.8) LV 212-2:2015-01 (p. 9.6.8) LV 216-1:2015-07 (p. 9.6.9) LV 216-2:2017-02 (p. 9.6.8) VW 60306-1:2018-09-01 (p. 9.6.9) VW 60306-1:2021-10 (p. 9.7.9) VW 60306-2:2013-04 (p. 9.6.9) VW 60306-2:2021-11 (p. 9.7.9) VW 60306-4:2021-12 (p. 9.7.9) VW 75205:2019-11 (p. 11.5.2) VW 75205:2023-05 (p. 11.5.2) VW 75205:2024-04 (p. 11.6.2) VW 75209-1:2015-01 (p. 9.6.8) VW 75209-1:2021-12 (p. 9.7.7) VW 75209-2:2015-01 (p. 9.6.8) VW 75209-2:2021-12 (p. 9.7.7) VW 75210-1:2023-06 (p. 9.7.9) VW 75210-1:2024-08 (p. 9.7.9) VW 75210-2:2023-06 (p. 9.7.8) MBN LV 112-1:2016-03 (p. 9.6.9) MBN 50112-1:2023-06 (p. 12.6.9) MBN LV 112-2:2012-01 (p. 8.7.8) MBN 50112-2:2023-05 (p. 12.7.8) MBN 50216-1:2023-07 (p. 12.7.8) MBN LV 122:2017-06 (p. 11.5.6) MBN 50122:2023-07 (p. 13.5.6) MBN LV 212-1:2017-08 (p. 9.6.8) MBN 50212-1:2023-04 (p. 12.7.8) MBN LV 216-2:2017-07 (p. 9.6.8) MBN 50112-4:2024-06 (p. 12.6.9) GS 95007-1-1:2013-05 (p. 9.6.9) GS 95007-1-2:2013-05 (p. 9.6.9) GS 95007-1-5:2015-07 (p. 11.5.2) GS 95007-3-1:2015-08 (p. 9.6.8) GS 95007-3-2:2015-09 (p. 9.6.8) Scope of accreditation No. AB 1776","norm_bases":["ISO 19642-2:2019-01 (p. 5.4.7; 6.4.7)","ISO 19642-2:2023 (p. 5.5.7; 6.5.7)","ISO 19642-3:2019-01 (p. 5.5.7)","ISO 19642-4:2019-01 (p. 5.5.7)","ISO 19642-5:2019-01 (p. 5.5.7)","ISO 19642-6:2019-01 (p. 5.5.7)","ISO 19642-7:2019-01 (p. 6.5.7)","ISO 19642-8:2019-01 (p. 6.5.7)","ISO 19642-9:2019-01 (p. 6.5.7)","ISO 19642-10:2019-01 (p. 6.5.7)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.10)","ISO 6722-2:2013-12-01 (p. 5.10)","ISO 14572:2011-10 (p. 5.10) LV 112-1:2013-04 (p. 9.6.9) LV 112-1:2014-04 (p. 9.6.9) LV 112-2:2007-11 (p. 8.7.8) LV 112-2:2013-04 (p. 9.6.9) LV 122:2015-05 (p. 11.5.2) LV 122:2016-02 (p. 11.5.6) LV 212-1:2015-01 (p. 9.6.8) LV 212-2:2015-01 (p. 9.6.8) LV 216-1:2015-07 (p. 9.6.9) LV 216-2:2017-02 (p. 9.6.8) VW 60306-1:2018-09-01 (p. 9.6.9) VW 60306-1:2021-10 (p. 9.7.9) VW 60306-2:2013-04 (p. 9.6.9) VW 60306-2:2021-11 (p. 9.7.9) VW 60306-4:2021-12 (p. 9.7.9) VW 75205:2019-11 (p. 11.5.2) VW 75205:2023-05 (p. 11.5.2) VW 75205:2024-04 (p. 11.6.2) VW 75209-1:2015-01 (p. 9.6.8) VW 75209-1:2021-12 (p. 9.7.7) VW 75209-2:2015-01 (p. 9.6.8) VW 75209-2:2021-12 (p. 9.7.7) VW 75210-1:2023-06 (p. 9.7.9) VW 75210-1:2024-08 (p. 9.7.9) VW 75210-2:2023-06 (p. 9.7.8) MBN LV 112-1:2016-03 (p. 9.6.9) MBN 50112-1:2023-06 (p. 12.6.9) MBN LV 112-2:2012-01 (p. 8.7.8) MBN 50112-2:2023-05 (p. 12.7.8) MBN 50216-1:2023-07 (p. 12.7.8) MBN LV 122:2017-06 (p. 11.5.6) MBN 50122:2023-07 (p. 13.5.6) MBN LV 212-1:2017-08 (p. 9.6.8) MBN 50212-1:2023-04 (p. 12.7.8) MBN LV 216-2:2017-07 (p. 9.6.8) MBN 50112-4:2024-06 (p. 12.6.9) GS 95007-1-1:2013-05 (p. 9.6.9) GS 95007-1-2:2013-05 (p. 9.6.9) GS 95007-1-5:2015-07 (p. 11.5.2) GS 95007-3-1:2015-08 (p. 9.6.8) GS 95007-3-2:2015-09 (p. 9.6.8) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Nawijanie kabla w niskiej temperaturze\nZakres:\nKomora klimatyczna -40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. ISO 19642-2:2019-01 (p. 5.4.7; 6.4.7) | ISO 19642-2:2023 (p. 5.5.7; 6.5.7) | ISO 19642-3:2019-01 (p. 5.5.7) | ISO 19642-4:2019-01 (p. 5.5.7) | ISO 19642-5:2019-01 (p. 5.5.7) | ISO 19642-6:2019-01 (p. 5.5.7) | ISO 19642-7:2019-01 (p. 6.5.7) | ISO 19642-8:2019-01 (p. 6.5.7) | ISO 19642-9:2019-01 (p. 6.5.7) | ISO 19642-10:2019-01 (p. 6.5.7) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.10) | ISO 6722-2:2013-12-01 (p. 5.10) | ISO 14572:2011-10 (p. 5.10) LV 112-1:2013-04 (p. 9.6.9) LV 112-1:2014-04 (p. 9.6.9) LV 112-2:2007-11 (p. 8.7.8) LV 112-2:2013-04 (p. 9.6.9) LV 122:2015-05 (p. 11.5.2) LV 122:2016-02 (p. 11.5.6) LV 212-1:2015-01 (p. 9.6.8) LV 212-2:2015-01 (p. 9.6.8) LV 216-1:2015-07 (p. 9.6.9) LV 216-2:2017-02 (p. 9.6.8) VW 60306-1:2018-09-01 (p. 9.6.9) VW 60306-1:2021-10 (p. 9.7.9) VW 60306-2:2013-04 (p. 9.6.9) VW 60306-2:2021-11 (p. 9.7.9) VW 60306-4:2021-12 (p. 9.7.9) VW 75205:2019-11 (p. 11.5.2) VW 75205:2023-05 (p. 11.5.2) VW 75205:2024-04 (p. 11.6.2) VW 75209-1:2015-01 (p. 9.6.8) VW 75209-1:2021-12 (p. 9.7.7) VW 75209-2:2015-01 (p. 9.6.8) VW 75209-2:2021-12 (p. 9.7.7) VW 75210-1:2023-06 (p. 9.7.9) VW 75210-1:2024-08 (p. 9.7.9) VW 75210-2:2023-06 (p. 9.7.8) MBN LV 112-1:2016-03 (p. 9.6.9) MBN 50112-1:2023-06 (p. 12.6.9) MBN LV 112-2:2012-01 (p. 8.7.8) MBN 50112-2:2023-05 (p. 12.7.8) MBN 50216-1:2023-07 (p. 12.7.8) MBN LV 122:2017-06 (p. 11.5.6) MBN 50122:2023-07 (p. 13.5.6) MBN LV 212-1:2017-08 (p. 9.6.8) MBN 50212-1:2023-04 (p. 12.7.8) MBN LV 216-2:2017-07 (p. 9.6.8) MBN 50112-4:2024-06 (p. 12.6.9) GS 95007-1-1:2013-05 (p. 9.6.9) GS 95007-1-2:2013-05 (p. 9.6.9) GS 95007-1-5:2015-07 (p. 11.5.2) GS 95007-3-1:2015-08 (p. 9.6.8) GS 95007-3-2:2015-09 (p. 9.6.8) Scope of accreditation No. AB 1776 Kable, Cables Nawijanie kabla w niskiej temperaturze\nZakres:\nKomora klimatyczna -40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. ISO 19642-2:2019-01 (p. 5.4.7; 6.4.7) | ISO 19642-2:2023 (p. 5.5.7; 6.5.7) | ISO 19642-3:2019-01 (p. 5.5.7) | ISO 19642-4:2019-01 (p. 5.5.7) | ISO 19642-5:2019-01 (p. 5.5.7) | ISO 19642-6:2019-01 (p. 5.5.7) | ISO 19642-7:2019-01 (p. 6.5.7) | ISO 19642-8:2019-01 (p. 6.5.7) | ISO 19642-9:2019-01 (p. 6.5.7) | ISO 19642-10:2019-01 (p. 6.5.7) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.10) | ISO 6722-2:2013-12-01 (p. 5.10) | ISO 14572:2011-10 (p. 5.10) LV 112-1:2013-04 (p. 9.6.9) LV 112-1:2014-04 (p. 9.6.9) LV 112-2:2007-11 (p. 8.7.8) LV 112-2:2013-04 (p. 9.6.9) LV 122:2015-05 (p. 11.5.2) LV 122:2016-02 (p. 11.5.6) LV 212-1:2015-01 (p. 9.6.8) LV 212-2:2015-01 (p. 9.6.8) LV 216-1:2015-07 (p. 9.6.9) LV 216-2:2017-02 (p. 9.6.8) VW 60306-1:2018-09-01 (p. 9.6.9) VW 60306-1:2021-10 (p. 9.7.9) VW 60306-2:2013-04 (p. 9.6.9) VW 60306-2:2021-11 (p. 9.7.9) VW 60306-4:2021-12 (p. 9.7.9) VW 75205:2019-11 (p. 11.5.2) VW 75205:2023-05 (p. 11.5.2) VW 75205:2024-04 (p. 11.6.2) VW 75209-1:2015-01 (p. 9.6.8) VW 75209-1:2021-12 (p. 9.7.7) VW 75209-2:2015-01 (p. 9.6.8) VW 75209-2:2021-12 (p. 9.7.7) VW 75210-1:2023-06 (p. 9.7.9) VW 75210-1:2024-08 (p. 9.7.9) VW 75210-2:2023-06 (p. 9.7.8) MBN LV 112-1:2016-03 (p. 9.6.9) MBN 50112-1:2023-06 (p. 12.6.9) MBN LV 112-2:2012-01 (p. 8.7.8) MBN 50112-2:2023-05 (p. 12.7.8) MBN 50216-1:2023-07 (p. 12.7.8) MBN LV 122:2017-06 (p. 11.5.6) MBN 50122:2023-07 (p. 13.5.6) MBN LV 212-1:2017-08 (p. 9.6.8) MBN 50212-1:2023-04 (p. 12.7.8) MBN LV 216-2:2017-07 (p. 9.6.8) MBN 50112-4:2024-06 (p. 12.6.9) GS 95007-1-1:2013-05 (p. 9.6.9) GS 95007-1-2:2013-05 (p. 9.6.9) GS 95007-1-5:2015-07 (p. 11.5.2) GS 95007-3-1:2015-08 (p. 9.6.8) GS 95007-3-2:2015-09 (p. 9.6.8) Scope of accreditation No. AB 1776","categories":["other"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Cable winding at low temperature Climatic chamber Range 0,5 kV to 6 kV D.C. ISO 19642-2:2019-01 (p. 5.4.7; 6.4.7) | ISO 19642-2:2023 (p. 5.5.7; 6.5.7) | ISO 19642-3:2019-01 (p. 5.5.7) | ISO 19642-4:2019-01 (p. 5.5.7) | ISO 19642-5:2019-01 (p. 5.5.7) | ISO 19642-6:2019-01 (p. 5.5.7) | ISO 19642-7:2019-01 (p. 6.5.7) | ISO 19642-8:2019-01 (p. 6.5.7) | ISO 19642-9:2019-01 (p. 6.5.7) | ISO 19642-10:2019-01 (p. 6.5.7) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.10) | ISO 6722-2:2013-12-01 (p. 5.10) | ISO 14572:2011-10 (p. 5.10) LV 112-1:2013-04 (p. 9.6.9) LV 112-1:2014-04 (p. 9.6.9) LV 112-2:2007-11 (p. 8.7.8) LV 112-2:2013-04 (p. 9.6.9) LV 122:2015-05 (p. 11.5.2) LV 122:2016-02 (p. 11.5.6) LV 212-1:2015-01 (p. 9.6.8) LV 212-2:2015-01 (p. 9.6.8) LV 216-1:2015-07 (p. 9.6.9) LV 216-2:2017-02 (p. 9.6.8) VW 60306-1:2018-09-01 (p. 9.6.9) VW 60306-1:2021-10 (p. 9.7.9) VW 60306-2:2013-04 (p. 9.6.9) VW 60306-2:2021-11 (p. 9.7.9) VW 60306-4:2021-12 (p. 9.7.9) VW 75205:2019-11 (p. 11.5.2) VW 75205:2023-05 (p. 11.5.2) VW 75205:2024-04 (p. 11.6.2) VW 75209-1:2015-01 (p. 9.6.8) VW 75209-1:2021-12 (p. 9.7.7) VW 75209-2:2015-01 (p. 9.6.8) VW 75209-2:2021-12 (p. 9.7.7) VW 75210-1:2023-06 (p. 9.7.9) VW 75210-1:2024-08 (p. 9.7.9) VW 75210-2:2023-06 (p. 9.7.8) MBN LV 112-1:2016-03 (p. 9.6.9) MBN 50112-1:2023-06 (p. 12.6.9) MBN LV 112-2:2012-01 (p. 8.7.8) MBN 50112-2:2023-05 (p. 12.7.8) MBN 50216-1:2023-07 (p. 12.7.8) MBN LV 122:2017-06 (p. 11.5.6) MBN 50122:2023-07 (p. 13.5.6) MBN LV 212-1:2017-08 (p. 9.6.8) MBN 50212-1:2023-04 (p. 12.7.8) MBN LV 216-2:2017-07 (p. 9.6.8) MBN 50112-4:2024-06 (p. 12.6.9) GS 95007-1-1:2013-05 (p. 9.6.9) GS 95007-1-2:2013-05 (p. 9.6.9) GS 95007-1-5:2015-07 (p. 11.5.2) GS 95007-3-1:2015-08 (p. 9.6.8) GS 95007-3-2:2015-09 (p. 9.6.8) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"气候试验箱","range":"-40 °C do 125 °C"},{"name":"范围","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV do 6 kV D.C."}],"search_zh":"电缆 气候试验箱 范围 ISO 19642-2:2019-01 (p. 5.4.7; 6.4.7) | ISO 19642-2:2023 (p. 5.5.7; 6.5.7) | ISO 19642-3:2019-01 (p. 5.5.7) | ISO 19642-4:2019-01 (p. 5.5.7) | ISO 19642-5:2019-01 (p. 5.5.7) | ISO 19642-6:2019-01 (p. 5.5.7) | ISO 19642-7:2019-01 (p. 6.5.7) | ISO 19642-8:2019-01 (p. 6.5.7) | ISO 19642-9:2019-01 (p. 6.5.7) | ISO 19642-10:2019-01 (p. 6.5.7) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.10) | ISO 6722-2:2013-12-01 (p. 5.10) | ISO 14572:2011-10 (p. 5.10) LV 112-1:2013-04 (p. 9.6.9) LV 112-1:2014-04 (p. 9.6.9) LV 112-2:2007-11 (p. 8.7.8) LV 112-2:2013-04 (p. 9.6.9) LV 122:2015-05 (p. 11.5.2) LV 122:2016-02 (p. 11.5.6) LV 212-1:2015-01 (p. 9.6.8) LV 212-2:2015-01 (p. 9.6.8) LV 216-1:2015-07 (p. 9.6.9) LV 216-2:2017-02 (p. 9.6.8) VW 60306-1:2018-09-01 (p. 9.6.9) VW 60306-1:2021-10 (p. 9.7.9) VW 60306-2:2013-04 (p. 9.6.9) VW 60306-2:2021-11 (p. 9.7.9) VW 60306-4:2021-12 (p. 9.7.9) VW 75205:2019-11 (p. 11.5.2) VW 75205:2023-05 (p. 11.5.2) VW 75205:2024-04 (p. 11.6.2) VW 75209-1:2015-01 (p. 9.6.8) VW 75209-1:2021-12 (p. 9.7.7) VW 75209-2:2015-01 (p. 9.6.8) VW 75209-2:2021-12 (p. 9.7.7) VW 75210-1:2023-06 (p. 9.7.9) VW 75210-1:2024-08 (p. 9.7.9) VW 75210-2:2023-06 (p. 9.7.8) MBN LV 112-1:2016-03 (p. 9.6.9) MBN 50112-1:2023-06 (p. 12.6.9) MBN LV 112-2:2012-01 (p. 8.7.8) MBN 50112-2:2023-05 (p. 12.7.8) MBN 50216-1:2023-07 (p. 12.7.8) MBN LV 122:2017-06 (p. 11.5.6) MBN 50122:2023-07 (p. 13.5.6) MBN LV 212-1:2017-08 (p. 9.6.8) MBN 50212-1:2023-04 (p. 12.7.8) MBN LV 216-2:2017-07 (p. 9.6.8) MBN 50112-4:2024-06 (p. 12.6.9) GS 95007-1-1:2013-05 (p. 9.6.9) GS 95007-1-2:2013-05 (p. 9.6.9) GS 95007-1-5:2015-07 (p. 11.5.2) GS 95007-3-1:2015-08 (p. 9.6.8) GS 95007-3-2:2015-09 (p. 9.6.8) Scope of accreditation No. AB 1776","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ed8","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"","methodology_en":null,"parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"","reference":"GS 95007-6-1:2016-03 (p. 9.6.9) GS 95007-6-2:2017-04 (p. 9.6.8)","norm_bases":["GS 95007-6-1:2016-03 (p. 9.6.9) GS 95007-6-2:2017-04 (p. 9.6.8)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables GS 95007-6-1:2016-03 (p. 9.6.9) GS 95007-6-2:2017-04 (p. 9.6.8) Kable, Cables GS 95007-6-1:2016-03 (p. 9.6.9) GS 95007-6-2:2017-04 (p. 9.6.8)","categories":["other"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables GS 95007-6-1:2016-03 (p. 9.6.9) GS 95007-6-2:2017-04 (p. 9.6.8)","search_zh":"电缆 GS 95007-6-1:2016-03 (p. 9.6.9) GS 95007-6-2:2017-04 (p. 9.6.8)","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ed9","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Uderzenie kabla w niskiej temperaturze","methodology_en":"Impact on the cable at low temperature","parameters":[{"name":"Komora klimatyczna","range":"-40 °C do 175 °C"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV do 6 kV D.C. Cold impact Range:"}],"parameters_en":[{"name":"Climatic chamber","range":"-40 °C do 175 °C"},{"name":"Range","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV to 6 kV D.C. Cold impact Range:"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Uderzenie kabla w niskiej temperaturze\nZakres:\nKomora klimatyczna -40 °C do 175 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. Cold impact Range:","reference":"ISO 19642-2:2019-01 (p. 5.4.8; 6.4.8) | ISO 19642-2:2023 (p. 5.5.8; 6.5.8) | ISO 19642-3:2019-01 (p. 5.5.8) | ISO 19642-4:2019-01 (p. 5.5.8) | ISO 19642-5:2019-01 (p. 5.5.8) | ISO 19642-6:2019-01 (p. 5.5.8) | ISO 19642-7:2019-01 (p. 6.5.8) | ISO 19642-8:2019-01 (p. 6.5.8) | ISO 19642-9:2019-01 (p. 6.5.8) | ISO 19642-10:2019-01 (p. 6.5.8) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.11) | ISO 6722-2:2013-12-01 (p. 5.11) | ISO 14572:2011-10 (p. 5.11) LV 112-1:2013-04 (p. 9.6.10) LV 112-1:2014-04 (p. 9.6.10) LV 112-2:2007-11 (p. 8.7.9) LV 112-2:2013-04 (p. 9.6.10) LV 212-1:2015-01 (p. 9.6.9) LV 212-2:2015-01 (p. 9.6.9) LV 216-1:2015-07 (p. 9.6.10) LV 216-2:2017-02 (p. 9.6.9) VW 60306-1:2018-09-01 (p. 9.6.10) VW 60306-1:2021-10 (p. 9.7.10) VW 60306-2:2013-04 (p. 9.6.10) VW 60306-2:2021-11 (p. 9.7.10) VW 60306-4:2021-12 (p. 9.7.10) VW 75209-1:2015-01 (p. 9.6.9) VW 75209-1:2021-12 (p. 9.7.8) VW 75209-2:2015-01 (p. 9.6.9) VW 75209-2:2021-12 (p. 9.7.8) VW 75210-1:2023-06 (p. 9.7.10) VW 75210-1:2024-08 (p. 9.7.10) VW 75210-2:2023-06 (p. 9.7.9) MBN LV 112-1:2016-03 (p. 9.6.10) MBN 50112-1:2023-06 (p. 12.6.10) MBN LV 112-2:2012-01 (p. 8.7.9) MBN 50112-2:2023-05 (p. 12.7.9) MBN 50216-1:2023-07 (p. 12.7.9) MBN LV 212-1:2017-08 (p. 9.6.9) MBN 50212-1:2023-04 (p. 12.7.9) MBN LV 216-2:2017-07 (p. 9.6.9) MBN 50112-4:2024-06 (p. 12.6.10) GS 95007-1-1:2013-05 (p. 9.6.10) GS 95007-1-2:2013-05 (p. 9.6.10) GS 95007-3-1:2015-08 (p. 9.6.9) GS 95007-3-2:2015-09 (p. 9.6.9) GS 95007-6-1:2016-03 (p. 9.6.10) GS 95007-6-2:2017-04 (p. 9.6.9) Scope of accreditation No. AB 1776","norm_bases":["ISO 19642-2:2019-01 (p. 5.4.8; 6.4.8)","ISO 19642-2:2023 (p. 5.5.8; 6.5.8)","ISO 19642-3:2019-01 (p. 5.5.8)","ISO 19642-4:2019-01 (p. 5.5.8)","ISO 19642-5:2019-01 (p. 5.5.8)","ISO 19642-6:2019-01 (p. 5.5.8)","ISO 19642-7:2019-01 (p. 6.5.8)","ISO 19642-8:2019-01 (p. 6.5.8)","ISO 19642-9:2019-01 (p. 6.5.8)","ISO 19642-10:2019-01 (p. 6.5.8)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.11)","ISO 6722-2:2013-12-01 (p. 5.11)","ISO 14572:2011-10 (p. 5.11) LV 112-1:2013-04 (p. 9.6.10) LV 112-1:2014-04 (p. 9.6.10) LV 112-2:2007-11 (p. 8.7.9) LV 112-2:2013-04 (p. 9.6.10) LV 212-1:2015-01 (p. 9.6.9) LV 212-2:2015-01 (p. 9.6.9) LV 216-1:2015-07 (p. 9.6.10) LV 216-2:2017-02 (p. 9.6.9) VW 60306-1:2018-09-01 (p. 9.6.10) VW 60306-1:2021-10 (p. 9.7.10) VW 60306-2:2013-04 (p. 9.6.10) VW 60306-2:2021-11 (p. 9.7.10) VW 60306-4:2021-12 (p. 9.7.10) VW 75209-1:2015-01 (p. 9.6.9) VW 75209-1:2021-12 (p. 9.7.8) VW 75209-2:2015-01 (p. 9.6.9) VW 75209-2:2021-12 (p. 9.7.8) VW 75210-1:2023-06 (p. 9.7.10) VW 75210-1:2024-08 (p. 9.7.10) VW 75210-2:2023-06 (p. 9.7.9) MBN LV 112-1:2016-03 (p. 9.6.10) MBN 50112-1:2023-06 (p. 12.6.10) MBN LV 112-2:2012-01 (p. 8.7.9) MBN 50112-2:2023-05 (p. 12.7.9) MBN 50216-1:2023-07 (p. 12.7.9) MBN LV 212-1:2017-08 (p. 9.6.9) MBN 50212-1:2023-04 (p. 12.7.9) MBN LV 216-2:2017-07 (p. 9.6.9) MBN 50112-4:2024-06 (p. 12.6.10) GS 95007-1-1:2013-05 (p. 9.6.10) GS 95007-1-2:2013-05 (p. 9.6.10) GS 95007-3-1:2015-08 (p. 9.6.9) GS 95007-3-2:2015-09 (p. 9.6.9) GS 95007-6-1:2016-03 (p. 9.6.10) GS 95007-6-2:2017-04 (p. 9.6.9) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Uderzenie kabla w niskiej temperaturze\nZakres:\nKomora klimatyczna -40 °C do 175 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. Cold impact Range: ISO 19642-2:2019-01 (p. 5.4.8; 6.4.8) | ISO 19642-2:2023 (p. 5.5.8; 6.5.8) | ISO 19642-3:2019-01 (p. 5.5.8) | ISO 19642-4:2019-01 (p. 5.5.8) | ISO 19642-5:2019-01 (p. 5.5.8) | ISO 19642-6:2019-01 (p. 5.5.8) | ISO 19642-7:2019-01 (p. 6.5.8) | ISO 19642-8:2019-01 (p. 6.5.8) | ISO 19642-9:2019-01 (p. 6.5.8) | ISO 19642-10:2019-01 (p. 6.5.8) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.11) | ISO 6722-2:2013-12-01 (p. 5.11) | ISO 14572:2011-10 (p. 5.11) LV 112-1:2013-04 (p. 9.6.10) LV 112-1:2014-04 (p. 9.6.10) LV 112-2:2007-11 (p. 8.7.9) LV 112-2:2013-04 (p. 9.6.10) LV 212-1:2015-01 (p. 9.6.9) LV 212-2:2015-01 (p. 9.6.9) LV 216-1:2015-07 (p. 9.6.10) LV 216-2:2017-02 (p. 9.6.9) VW 60306-1:2018-09-01 (p. 9.6.10) VW 60306-1:2021-10 (p. 9.7.10) VW 60306-2:2013-04 (p. 9.6.10) VW 60306-2:2021-11 (p. 9.7.10) VW 60306-4:2021-12 (p. 9.7.10) VW 75209-1:2015-01 (p. 9.6.9) VW 75209-1:2021-12 (p. 9.7.8) VW 75209-2:2015-01 (p. 9.6.9) VW 75209-2:2021-12 (p. 9.7.8) VW 75210-1:2023-06 (p. 9.7.10) VW 75210-1:2024-08 (p. 9.7.10) VW 75210-2:2023-06 (p. 9.7.9) MBN LV 112-1:2016-03 (p. 9.6.10) MBN 50112-1:2023-06 (p. 12.6.10) MBN LV 112-2:2012-01 (p. 8.7.9) MBN 50112-2:2023-05 (p. 12.7.9) MBN 50216-1:2023-07 (p. 12.7.9) MBN LV 212-1:2017-08 (p. 9.6.9) MBN 50212-1:2023-04 (p. 12.7.9) MBN LV 216-2:2017-07 (p. 9.6.9) MBN 50112-4:2024-06 (p. 12.6.10) GS 95007-1-1:2013-05 (p. 9.6.10) GS 95007-1-2:2013-05 (p. 9.6.10) GS 95007-3-1:2015-08 (p. 9.6.9) GS 95007-3-2:2015-09 (p. 9.6.9) GS 95007-6-1:2016-03 (p. 9.6.10) GS 95007-6-2:2017-04 (p. 9.6.9) Scope of accreditation No. AB 1776 Kable, Cables Uderzenie kabla w niskiej temperaturze\nZakres:\nKomora klimatyczna -40 °C do 175 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. Cold impact Range: ISO 19642-2:2019-01 (p. 5.4.8; 6.4.8) | ISO 19642-2:2023 (p. 5.5.8; 6.5.8) | ISO 19642-3:2019-01 (p. 5.5.8) | ISO 19642-4:2019-01 (p. 5.5.8) | ISO 19642-5:2019-01 (p. 5.5.8) | ISO 19642-6:2019-01 (p. 5.5.8) | ISO 19642-7:2019-01 (p. 6.5.8) | ISO 19642-8:2019-01 (p. 6.5.8) | ISO 19642-9:2019-01 (p. 6.5.8) | ISO 19642-10:2019-01 (p. 6.5.8) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.11) | ISO 6722-2:2013-12-01 (p. 5.11) | ISO 14572:2011-10 (p. 5.11) LV 112-1:2013-04 (p. 9.6.10) LV 112-1:2014-04 (p. 9.6.10) LV 112-2:2007-11 (p. 8.7.9) LV 112-2:2013-04 (p. 9.6.10) LV 212-1:2015-01 (p. 9.6.9) LV 212-2:2015-01 (p. 9.6.9) LV 216-1:2015-07 (p. 9.6.10) LV 216-2:2017-02 (p. 9.6.9) VW 60306-1:2018-09-01 (p. 9.6.10) VW 60306-1:2021-10 (p. 9.7.10) VW 60306-2:2013-04 (p. 9.6.10) VW 60306-2:2021-11 (p. 9.7.10) VW 60306-4:2021-12 (p. 9.7.10) VW 75209-1:2015-01 (p. 9.6.9) VW 75209-1:2021-12 (p. 9.7.8) VW 75209-2:2015-01 (p. 9.6.9) VW 75209-2:2021-12 (p. 9.7.8) VW 75210-1:2023-06 (p. 9.7.10) VW 75210-1:2024-08 (p. 9.7.10) VW 75210-2:2023-06 (p. 9.7.9) MBN LV 112-1:2016-03 (p. 9.6.10) MBN 50112-1:2023-06 (p. 12.6.10) MBN LV 112-2:2012-01 (p. 8.7.9) MBN 50112-2:2023-05 (p. 12.7.9) MBN 50216-1:2023-07 (p. 12.7.9) MBN LV 212-1:2017-08 (p. 9.6.9) MBN 50212-1:2023-04 (p. 12.7.9) MBN LV 216-2:2017-07 (p. 9.6.9) MBN 50112-4:2024-06 (p. 12.6.10) GS 95007-1-1:2013-05 (p. 9.6.10) GS 95007-1-2:2013-05 (p. 9.6.10) GS 95007-3-1:2015-08 (p. 9.6.9) GS 95007-3-2:2015-09 (p. 9.6.9) GS 95007-6-1:2016-03 (p. 9.6.10) GS 95007-6-2:2017-04 (p. 9.6.9) Scope of accreditation No. AB 1776","categories":["other"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Impact on the cable at low temperature Climatic chamber Range 0,5 kV to 6 kV D.C. Cold impact Range: ISO 19642-2:2019-01 (p. 5.4.8; 6.4.8) | ISO 19642-2:2023 (p. 5.5.8; 6.5.8) | ISO 19642-3:2019-01 (p. 5.5.8) | ISO 19642-4:2019-01 (p. 5.5.8) | ISO 19642-5:2019-01 (p. 5.5.8) | ISO 19642-6:2019-01 (p. 5.5.8) | ISO 19642-7:2019-01 (p. 6.5.8) | ISO 19642-8:2019-01 (p. 6.5.8) | ISO 19642-9:2019-01 (p. 6.5.8) | ISO 19642-10:2019-01 (p. 6.5.8) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.11) | ISO 6722-2:2013-12-01 (p. 5.11) | ISO 14572:2011-10 (p. 5.11) LV 112-1:2013-04 (p. 9.6.10) LV 112-1:2014-04 (p. 9.6.10) LV 112-2:2007-11 (p. 8.7.9) LV 112-2:2013-04 (p. 9.6.10) LV 212-1:2015-01 (p. 9.6.9) LV 212-2:2015-01 (p. 9.6.9) LV 216-1:2015-07 (p. 9.6.10) LV 216-2:2017-02 (p. 9.6.9) VW 60306-1:2018-09-01 (p. 9.6.10) VW 60306-1:2021-10 (p. 9.7.10) VW 60306-2:2013-04 (p. 9.6.10) VW 60306-2:2021-11 (p. 9.7.10) VW 60306-4:2021-12 (p. 9.7.10) VW 75209-1:2015-01 (p. 9.6.9) VW 75209-1:2021-12 (p. 9.7.8) VW 75209-2:2015-01 (p. 9.6.9) VW 75209-2:2021-12 (p. 9.7.8) VW 75210-1:2023-06 (p. 9.7.10) VW 75210-1:2024-08 (p. 9.7.10) VW 75210-2:2023-06 (p. 9.7.9) MBN LV 112-1:2016-03 (p. 9.6.10) MBN 50112-1:2023-06 (p. 12.6.10) MBN LV 112-2:2012-01 (p. 8.7.9) MBN 50112-2:2023-05 (p. 12.7.9) MBN 50216-1:2023-07 (p. 12.7.9) MBN LV 212-1:2017-08 (p. 9.6.9) MBN 50212-1:2023-04 (p. 12.7.9) MBN LV 216-2:2017-07 (p. 9.6.9) MBN 50112-4:2024-06 (p. 12.6.10) GS 95007-1-1:2013-05 (p. 9.6.10) GS 95007-1-2:2013-05 (p. 9.6.10) GS 95007-3-1:2015-08 (p. 9.6.9) GS 95007-3-2:2015-09 (p. 9.6.9) GS 95007-6-1:2016-03 (p. 9.6.10) GS 95007-6-2:2017-04 (p. 9.6.9) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"气候试验箱","range":"-40 °C do 175 °C"},{"name":"范围","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV do 6 kV D.C. Cold impact Range:"}],"search_zh":"电缆 气候试验箱 范围 ISO 19642-2:2019-01 (p. 5.4.8; 6.4.8) | ISO 19642-2:2023 (p. 5.5.8; 6.5.8) | ISO 19642-3:2019-01 (p. 5.5.8) | ISO 19642-4:2019-01 (p. 5.5.8) | ISO 19642-5:2019-01 (p. 5.5.8) | ISO 19642-6:2019-01 (p. 5.5.8) | ISO 19642-7:2019-01 (p. 6.5.8) | ISO 19642-8:2019-01 (p. 6.5.8) | ISO 19642-9:2019-01 (p. 6.5.8) | ISO 19642-10:2019-01 (p. 6.5.8) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.11) | ISO 6722-2:2013-12-01 (p. 5.11) | ISO 14572:2011-10 (p. 5.11) LV 112-1:2013-04 (p. 9.6.10) LV 112-1:2014-04 (p. 9.6.10) LV 112-2:2007-11 (p. 8.7.9) LV 112-2:2013-04 (p. 9.6.10) LV 212-1:2015-01 (p. 9.6.9) LV 212-2:2015-01 (p. 9.6.9) LV 216-1:2015-07 (p. 9.6.10) LV 216-2:2017-02 (p. 9.6.9) VW 60306-1:2018-09-01 (p. 9.6.10) VW 60306-1:2021-10 (p. 9.7.10) VW 60306-2:2013-04 (p. 9.6.10) VW 60306-2:2021-11 (p. 9.7.10) VW 60306-4:2021-12 (p. 9.7.10) VW 75209-1:2015-01 (p. 9.6.9) VW 75209-1:2021-12 (p. 9.7.8) VW 75209-2:2015-01 (p. 9.6.9) VW 75209-2:2021-12 (p. 9.7.8) VW 75210-1:2023-06 (p. 9.7.10) VW 75210-1:2024-08 (p. 9.7.10) VW 75210-2:2023-06 (p. 9.7.9) MBN LV 112-1:2016-03 (p. 9.6.10) MBN 50112-1:2023-06 (p. 12.6.10) MBN LV 112-2:2012-01 (p. 8.7.9) MBN 50112-2:2023-05 (p. 12.7.9) MBN 50216-1:2023-07 (p. 12.7.9) MBN LV 212-1:2017-08 (p. 9.6.9) MBN 50212-1:2023-04 (p. 12.7.9) MBN LV 216-2:2017-07 (p. 9.6.9) MBN 50112-4:2024-06 (p. 12.6.10) GS 95007-1-1:2013-05 (p. 9.6.10) GS 95007-1-2:2013-05 (p. 9.6.10) GS 95007-3-1:2015-08 (p. 9.6.9) GS 95007-3-2:2015-09 (p. 9.6.9) GS 95007-6-1:2016-03 (p. 9.6.10) GS 95007-6-2:2017-04 (p. 9.6.9) Scope of accreditation No. AB 1776","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259eda","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Cykliczne zmiany temperatury i wilgotności","methodology_en":"Cyclic temperature and humidity changes","parameters":[{"name":"Komora klimatyczna","range":"-40°C do 175°C,"},{"name":"(90 ±10) % RH"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV do 6 kV D.C."}],"parameters_en":[{"name":"Climatic chamber","range":"-40°C do 175°C,"},{"name":"(90 ±10) % RH"},{"name":"Range","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Cykliczne zmiany temperatury i wilgotności\nZakres:\nKomora klimatyczna -40°C do 175°C,\n(90 ±10) % RH\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C.","reference":"ISO 19642-2:2019-01 (p. 5.4.9; 6.4.9) | ISO 19642-2:2023 (p. 5.5.9; 6.5.9) | ISO 19642-3:2019-01 (p. 5.5.9) | ISO 19642-4:2019-01 (p. 5.5.9) | ISO 19642-5:2019-01 (p. 5.5.9) | ISO 19642-6:2019-01 (p. 5.5.9) | ISO 19642-7:2019-01 (p. 6.5.9) | ISO 19642-8:2019-01 (p. 6.5.9) | ISO 19642-9:2019-01 (p. 6.5.9) | ISO 19642-10:2019-01 (p. 6.5.9) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.21) | ISO 6722-2:2013-12-01 (p. 5.21) | ISO 14572:2011-10 (p. 5.20)","norm_bases":["ISO 19642-2:2019-01 (p. 5.4.9; 6.4.9)","ISO 19642-2:2023 (p. 5.5.9; 6.5.9)","ISO 19642-3:2019-01 (p. 5.5.9)","ISO 19642-4:2019-01 (p. 5.5.9)","ISO 19642-5:2019-01 (p. 5.5.9)","ISO 19642-6:2019-01 (p. 5.5.9)","ISO 19642-7:2019-01 (p. 6.5.9)","ISO 19642-8:2019-01 (p. 6.5.9)","ISO 19642-9:2019-01 (p. 6.5.9)","ISO 19642-10:2019-01 (p. 6.5.9)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.21)","ISO 6722-2:2013-12-01 (p. 5.21)","ISO 14572:2011-10 (p. 5.20)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Cykliczne zmiany temperatury i wilgotności\nZakres:\nKomora klimatyczna -40°C do 175°C,\n(90 ±10) % RH\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. ISO 19642-2:2019-01 (p. 5.4.9; 6.4.9) | ISO 19642-2:2023 (p. 5.5.9; 6.5.9) | ISO 19642-3:2019-01 (p. 5.5.9) | ISO 19642-4:2019-01 (p. 5.5.9) | ISO 19642-5:2019-01 (p. 5.5.9) | ISO 19642-6:2019-01 (p. 5.5.9) | ISO 19642-7:2019-01 (p. 6.5.9) | ISO 19642-8:2019-01 (p. 6.5.9) | ISO 19642-9:2019-01 (p. 6.5.9) | ISO 19642-10:2019-01 (p. 6.5.9) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.21) | ISO 6722-2:2013-12-01 (p. 5.21) | ISO 14572:2011-10 (p. 5.20) Kable, Cables Cykliczne zmiany temperatury i wilgotnosci\nZakres:\nKomora klimatyczna -40°C do 175°C,\n(90 ±10) % RH\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. ISO 19642-2:2019-01 (p. 5.4.9; 6.4.9) | ISO 19642-2:2023 (p. 5.5.9; 6.5.9) | ISO 19642-3:2019-01 (p. 5.5.9) | ISO 19642-4:2019-01 (p. 5.5.9) | ISO 19642-5:2019-01 (p. 5.5.9) | ISO 19642-6:2019-01 (p. 5.5.9) | ISO 19642-7:2019-01 (p. 6.5.9) | ISO 19642-8:2019-01 (p. 6.5.9) | ISO 19642-9:2019-01 (p. 6.5.9) | ISO 19642-10:2019-01 (p. 6.5.9) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.21) | ISO 6722-2:2013-12-01 (p. 5.21) | ISO 14572:2011-10 (p. 5.20)","categories":["other"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Cyclic temperature and humidity changes Climatic chamber (90 ±10) % RH Range 0,5 kV to 6 kV D.C. ISO 19642-2:2019-01 (p. 5.4.9; 6.4.9) | ISO 19642-2:2023 (p. 5.5.9; 6.5.9) | ISO 19642-3:2019-01 (p. 5.5.9) | ISO 19642-4:2019-01 (p. 5.5.9) | ISO 19642-5:2019-01 (p. 5.5.9) | ISO 19642-6:2019-01 (p. 5.5.9) | ISO 19642-7:2019-01 (p. 6.5.9) | ISO 19642-8:2019-01 (p. 6.5.9) | ISO 19642-9:2019-01 (p. 6.5.9) | ISO 19642-10:2019-01 (p. 6.5.9) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.21) | ISO 6722-2:2013-12-01 (p. 5.21) | ISO 14572:2011-10 (p. 5.20)","parameters_zh":[{"name":"气候试验箱","range":"-40°C do 175°C,"},{"name":"(90 ±10) % RH"},{"name":"范围","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV do 6 kV D.C."}],"search_zh":"电缆 气候试验箱 范围 ISO 19642-2:2019-01 (p. 5.4.9; 6.4.9) | ISO 19642-2:2023 (p. 5.5.9; 6.5.9) | ISO 19642-3:2019-01 (p. 5.5.9) | ISO 19642-4:2019-01 (p. 5.5.9) | ISO 19642-5:2019-01 (p. 5.5.9) | ISO 19642-6:2019-01 (p. 5.5.9) | ISO 19642-7:2019-01 (p. 6.5.9) | ISO 19642-8:2019-01 (p. 6.5.9) | ISO 19642-9:2019-01 (p. 6.5.9) | ISO 19642-10:2019-01 (p. 6.5.9) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.21) | ISO 6722-2:2013-12-01 (p. 5.21) | ISO 14572:2011-10 (p. 5.20)","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259edb","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"","methodology_en":null,"parameters":[{"name":"Odporność na gorącą wodę"},{"name":"Właściwości elektryczne podczas starzenia w wodzie"},{"name":"Napięcie","range":"1 V do 1000 V D.C."},{"name":"Rezystancja","range":"2 kΩ - 1000 GΩ"},{"name":"Łaźnia: temperatura","range":"do 90°C"}],"parameters_en":[{"name":"Resistance to hot water"},{"name":"Electrical properties during ageing in water"},{"name":"Voltage","range":"1 V do 1000 V D.C."},{"name":"Resistance","range":"2 kΩ - 1000 GΩ"},{"name":"Bath: temperature","range":"do 90°C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"\nZakres:\nOdporność na gorącą wodę\nWłaściwości elektryczne podczas starzenia w wodzie\nNapięcie 1 V do 1000 V D.C.\nRezystancja 2 kΩ - 1000 GΩ\nŁaźnia: temperatura do 90°C","reference":"ISO 19642-2:2019-01 (p. 5.4.10) | ISO 19642-2:2023 (p. 5.5.10) | ISO 19642-3:2019-01 (p. 5.5.10) | ISO 19642-4:2019-01 (p. 5.5.10) | ISO 19642-5:2019-01 (p. 5.5.10) | ISO 19642-6:2019-01 (p. 5.5.10) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.20) | ISO 6722-2:2013-12-01 (p. 5.20) LV 112-1:2013-04 (p. 9.6.14) LV 112-1:2014-04 (p. 9.6.14) LV 112-2:2007-11 (p. 8.7.13) LV 112-2:2013-04 (p. 9.6.14) LV 122:2015-05 (p. 11.6) LV 122:2016-02 (p. 11.6) LV 212-1:2015-01 (p. 9.6.12) LV 212-2:2015-01 (p. 9.6.12) LV 216-1:2015-07 (p. 9.6.14) VW 60306-1:2018-09-01 (p. 9.6.14) VW 60306-1:2021-10 (p. 9.7.14) VW 60306-2:2013-04 (p. 9.6.14) VW 60306-2:2021-11 (p. 9.7.14) VW 60306-4:2021-12 (p. 9.7.14) VW 75205:2019-11 (p. 11.6) VW 75205:2023-05 (p. 11.6) VW 75205:2024-04 (p. 11.7) VW 75209-1:2015-01 (p. 9.6.12) VW 75209-2:2015-01 (p. 9.6.12) VW 75209-2:2021-12 (p. 9.7.11) VW 75210-1:2023-06 (p. 9.7.14) VW 75210-1:2024-08 (p. 9.7.14) MBN LV 112-1:2016-03 (p. 9.6.14) MBN 50112-1:2023-06 (p. 12.6.14) MBN LV 112-2:2012-01 (p. 8.7.13) MBN 50112-2:2023-05 (p. 12.7.13) MBN 50216-1:2023-07 (p. 12.7.13) MBN LV 122:2017-06 (p. 11.6) Scope of accreditation No. AB 1776","norm_bases":["ISO 19642-2:2019-01 (p. 5.4.10)","ISO 19642-2:2023 (p. 5.5.10)","ISO 19642-3:2019-01 (p. 5.5.10)","ISO 19642-4:2019-01 (p. 5.5.10)","ISO 19642-5:2019-01 (p. 5.5.10)","ISO 19642-6:2019-01 (p. 5.5.10)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.20)","ISO 6722-2:2013-12-01 (p. 5.20) LV 112-1:2013-04 (p. 9.6.14) LV 112-1:2014-04 (p. 9.6.14) LV 112-2:2007-11 (p. 8.7.13) LV 112-2:2013-04 (p. 9.6.14) LV 122:2015-05 (p. 11.6) LV 122:2016-02 (p. 11.6) LV 212-1:2015-01 (p. 9.6.12) LV 212-2:2015-01 (p. 9.6.12) LV 216-1:2015-07 (p. 9.6.14) VW 60306-1:2018-09-01 (p. 9.6.14) VW 60306-1:2021-10 (p. 9.7.14) VW 60306-2:2013-04 (p. 9.6.14) VW 60306-2:2021-11 (p. 9.7.14) VW 60306-4:2021-12 (p. 9.7.14) VW 75205:2019-11 (p. 11.6) VW 75205:2023-05 (p. 11.6) VW 75205:2024-04 (p. 11.7) VW 75209-1:2015-01 (p. 9.6.12) VW 75209-2:2015-01 (p. 9.6.12) VW 75209-2:2021-12 (p. 9.7.11) VW 75210-1:2023-06 (p. 9.7.14) VW 75210-1:2024-08 (p. 9.7.14) MBN LV 112-1:2016-03 (p. 9.6.14) MBN 50112-1:2023-06 (p. 12.6.14) MBN LV 112-2:2012-01 (p. 8.7.13) MBN 50112-2:2023-05 (p. 12.7.13) MBN 50216-1:2023-07 (p. 12.7.13) MBN LV 122:2017-06 (p. 11.6) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables \nZakres:\nOdporność na gorącą wodę\nWłaściwości elektryczne podczas starzenia w wodzie\nNapięcie 1 V do 1000 V D.C.\nRezystancja 2 kΩ - 1000 GΩ\nŁaźnia: temperatura do 90°C ISO 19642-2:2019-01 (p. 5.4.10) | ISO 19642-2:2023 (p. 5.5.10) | ISO 19642-3:2019-01 (p. 5.5.10) | ISO 19642-4:2019-01 (p. 5.5.10) | ISO 19642-5:2019-01 (p. 5.5.10) | ISO 19642-6:2019-01 (p. 5.5.10) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.20) | ISO 6722-2:2013-12-01 (p. 5.20) LV 112-1:2013-04 (p. 9.6.14) LV 112-1:2014-04 (p. 9.6.14) LV 112-2:2007-11 (p. 8.7.13) LV 112-2:2013-04 (p. 9.6.14) LV 122:2015-05 (p. 11.6) LV 122:2016-02 (p. 11.6) LV 212-1:2015-01 (p. 9.6.12) LV 212-2:2015-01 (p. 9.6.12) LV 216-1:2015-07 (p. 9.6.14) VW 60306-1:2018-09-01 (p. 9.6.14) VW 60306-1:2021-10 (p. 9.7.14) VW 60306-2:2013-04 (p. 9.6.14) VW 60306-2:2021-11 (p. 9.7.14) VW 60306-4:2021-12 (p. 9.7.14) VW 75205:2019-11 (p. 11.6) VW 75205:2023-05 (p. 11.6) VW 75205:2024-04 (p. 11.7) VW 75209-1:2015-01 (p. 9.6.12) VW 75209-2:2015-01 (p. 9.6.12) VW 75209-2:2021-12 (p. 9.7.11) VW 75210-1:2023-06 (p. 9.7.14) VW 75210-1:2024-08 (p. 9.7.14) MBN LV 112-1:2016-03 (p. 9.6.14) MBN 50112-1:2023-06 (p. 12.6.14) MBN LV 112-2:2012-01 (p. 8.7.13) MBN 50112-2:2023-05 (p. 12.7.13) MBN 50216-1:2023-07 (p. 12.7.13) MBN LV 122:2017-06 (p. 11.6) Scope of accreditation No. AB 1776 Kable, Cables \nZakres:\nOdpornosc na goraca wode\nWlasciwosci elektryczne podczas starzenia w wodzie\nNapiecie 1 V do 1000 V D.C.\nRezystancja 2 kΩ - 1000 GΩ\nLaznia: temperatura do 90°C ISO 19642-2:2019-01 (p. 5.4.10) | ISO 19642-2:2023 (p. 5.5.10) | ISO 19642-3:2019-01 (p. 5.5.10) | ISO 19642-4:2019-01 (p. 5.5.10) | ISO 19642-5:2019-01 (p. 5.5.10) | ISO 19642-6:2019-01 (p. 5.5.10) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.20) | ISO 6722-2:2013-12-01 (p. 5.20) LV 112-1:2013-04 (p. 9.6.14) LV 112-1:2014-04 (p. 9.6.14) LV 112-2:2007-11 (p. 8.7.13) LV 112-2:2013-04 (p. 9.6.14) LV 122:2015-05 (p. 11.6) LV 122:2016-02 (p. 11.6) LV 212-1:2015-01 (p. 9.6.12) LV 212-2:2015-01 (p. 9.6.12) LV 216-1:2015-07 (p. 9.6.14) VW 60306-1:2018-09-01 (p. 9.6.14) VW 60306-1:2021-10 (p. 9.7.14) VW 60306-2:2013-04 (p. 9.6.14) VW 60306-2:2021-11 (p. 9.7.14) VW 60306-4:2021-12 (p. 9.7.14) VW 75205:2019-11 (p. 11.6) VW 75205:2023-05 (p. 11.6) VW 75205:2024-04 (p. 11.7) VW 75209-1:2015-01 (p. 9.6.12) VW 75209-2:2015-01 (p. 9.6.12) VW 75209-2:2021-12 (p. 9.7.11) VW 75210-1:2023-06 (p. 9.7.14) VW 75210-1:2024-08 (p. 9.7.14) MBN LV 112-1:2016-03 (p. 9.6.14) MBN 50112-1:2023-06 (p. 12.6.14) MBN LV 112-2:2012-01 (p. 8.7.13) MBN 50112-2:2023-05 (p. 12.7.13) MBN 50216-1:2023-07 (p. 12.7.13) MBN LV 122:2017-06 (p. 11.6) Scope of accreditation No. AB 1776","categories":["other"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Resistance to hot water Electrical properties during ageing in water Voltage Resistance Bath: temperature ISO 19642-2:2019-01 (p. 5.4.10) | ISO 19642-2:2023 (p. 5.5.10) | ISO 19642-3:2019-01 (p. 5.5.10) | ISO 19642-4:2019-01 (p. 5.5.10) | ISO 19642-5:2019-01 (p. 5.5.10) | ISO 19642-6:2019-01 (p. 5.5.10) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.20) | ISO 6722-2:2013-12-01 (p. 5.20) LV 112-1:2013-04 (p. 9.6.14) LV 112-1:2014-04 (p. 9.6.14) LV 112-2:2007-11 (p. 8.7.13) LV 112-2:2013-04 (p. 9.6.14) LV 122:2015-05 (p. 11.6) LV 122:2016-02 (p. 11.6) LV 212-1:2015-01 (p. 9.6.12) LV 212-2:2015-01 (p. 9.6.12) LV 216-1:2015-07 (p. 9.6.14) VW 60306-1:2018-09-01 (p. 9.6.14) VW 60306-1:2021-10 (p. 9.7.14) VW 60306-2:2013-04 (p. 9.6.14) VW 60306-2:2021-11 (p. 9.7.14) VW 60306-4:2021-12 (p. 9.7.14) VW 75205:2019-11 (p. 11.6) VW 75205:2023-05 (p. 11.6) VW 75205:2024-04 (p. 11.7) VW 75209-1:2015-01 (p. 9.6.12) VW 75209-2:2015-01 (p. 9.6.12) VW 75209-2:2021-12 (p. 9.7.11) VW 75210-1:2023-06 (p. 9.7.14) VW 75210-1:2024-08 (p. 9.7.14) MBN LV 112-1:2016-03 (p. 9.6.14) MBN 50112-1:2023-06 (p. 12.6.14) MBN LV 112-2:2012-01 (p. 8.7.13) MBN 50112-2:2023-05 (p. 12.7.13) MBN 50216-1:2023-07 (p. 12.7.13) MBN LV 122:2017-06 (p. 11.6) Scope of accreditation No. AB 1776","search_zh":"电缆 电压 电阻 ISO 19642-2:2019-01 (p. 5.4.10) | ISO 19642-2:2023 (p. 5.5.10) | ISO 19642-3:2019-01 (p. 5.5.10) | ISO 19642-4:2019-01 (p. 5.5.10) | ISO 19642-5:2019-01 (p. 5.5.10) | ISO 19642-6:2019-01 (p. 5.5.10) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.20) | ISO 6722-2:2013-12-01 (p. 5.20) LV 112-1:2013-04 (p. 9.6.14) LV 112-1:2014-04 (p. 9.6.14) LV 112-2:2007-11 (p. 8.7.13) LV 112-2:2013-04 (p. 9.6.14) LV 122:2015-05 (p. 11.6) LV 122:2016-02 (p. 11.6) LV 212-1:2015-01 (p. 9.6.12) LV 212-2:2015-01 (p. 9.6.12) LV 216-1:2015-07 (p. 9.6.14) VW 60306-1:2018-09-01 (p. 9.6.14) VW 60306-1:2021-10 (p. 9.7.14) VW 60306-2:2013-04 (p. 9.6.14) VW 60306-2:2021-11 (p. 9.7.14) VW 60306-4:2021-12 (p. 9.7.14) VW 75205:2019-11 (p. 11.6) VW 75205:2023-05 (p. 11.6) VW 75205:2024-04 (p. 11.7) VW 75209-1:2015-01 (p. 9.6.12) VW 75209-2:2015-01 (p. 9.6.12) VW 75209-2:2021-12 (p. 9.7.11) VW 75210-1:2023-06 (p. 9.7.14) VW 75210-1:2024-08 (p. 9.7.14) MBN LV 112-1:2016-03 (p. 9.6.14) MBN 50112-1:2023-06 (p. 12.6.14) MBN LV 112-2:2012-01 (p. 8.7.13) MBN 50112-2:2023-05 (p. 12.7.13) MBN 50216-1:2023-07 (p. 12.7.13) MBN LV 122:2017-06 (p. 11.6) Scope of accreditation No. AB 1776","test_object_zh":"电缆","parameters_zh":[{"name":"Odporność na gorącą wodę"},{"name":"Właściwości elektryczne podczas starzenia w wodzie"},{"name":"电压","range":"1 V do 1000 V D.C."},{"name":"电阻","range":"2 kΩ - 1000 GΩ"},{"name":"Łaźnia: temperatura","range":"do 90°C"}]},{"_id":"6a5dc9a9f1c10c8ce8259edc","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"","methodology_en":null,"parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"","reference":"MBN 50122:2023-07 (p. 13.6) MBN LV 212-1:2017-08 (p. 9.6.12) MBN 50112-4:2024-06 (p. 12.6.14) GS 95007-1-1:2013-05 (p. 9.6.14) GS 95007-1-2:2013-05 (p. 9.6.14) GS 95007-1-5:2015-07 (p. 11.6) GS 95007-3-1:2015-08 (p. 9.6.12) GS 95007-3-2:2015-09 (p. 9.6.12) GS 95007-6-1:2016-03 (p. 9.6.14)","norm_bases":["MBN 50122:2023-07 (p. 13.6) MBN LV 212-1:2017-08 (p. 9.6.12) MBN 50112-4:2024-06 (p. 12.6.14) GS 95007-1-1:2013-05 (p. 9.6.14) GS 95007-1-2:2013-05 (p. 9.6.14) GS 95007-1-5:2015-07 (p. 11.6) GS 95007-3-1:2015-08 (p. 9.6.12) GS 95007-3-2:2015-09 (p. 9.6.12) GS 95007-6-1:2016-03 (p. 9.6.14)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables MBN 50122:2023-07 (p. 13.6) MBN LV 212-1:2017-08 (p. 9.6.12) MBN 50112-4:2024-06 (p. 12.6.14) GS 95007-1-1:2013-05 (p. 9.6.14) GS 95007-1-2:2013-05 (p. 9.6.14) GS 95007-1-5:2015-07 (p. 11.6) GS 95007-3-1:2015-08 (p. 9.6.12) GS 95007-3-2:2015-09 (p. 9.6.12) GS 95007-6-1:2016-03 (p. 9.6.14) Kable, Cables MBN 50122:2023-07 (p. 13.6) MBN LV 212-1:2017-08 (p. 9.6.12) MBN 50112-4:2024-06 (p. 12.6.14) GS 95007-1-1:2013-05 (p. 9.6.14) GS 95007-1-2:2013-05 (p. 9.6.14) GS 95007-1-5:2015-07 (p. 11.6) GS 95007-3-1:2015-08 (p. 9.6.12) GS 95007-3-2:2015-09 (p. 9.6.12) GS 95007-6-1:2016-03 (p. 9.6.14)","categories":["other"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables MBN 50122:2023-07 (p. 13.6) MBN LV 212-1:2017-08 (p. 9.6.12) MBN 50112-4:2024-06 (p. 12.6.14) GS 95007-1-1:2013-05 (p. 9.6.14) GS 95007-1-2:2013-05 (p. 9.6.14) GS 95007-1-5:2015-07 (p. 11.6) GS 95007-3-1:2015-08 (p. 9.6.12) GS 95007-3-2:2015-09 (p. 9.6.12) GS 95007-6-1:2016-03 (p. 9.6.14)","search_zh":"电缆 MBN 50122:2023-07 (p. 13.6) MBN LV 212-1:2017-08 (p. 9.6.12) MBN 50112-4:2024-06 (p. 12.6.14) GS 95007-1-1:2013-05 (p. 9.6.14) GS 95007-1-2:2013-05 (p. 9.6.14) GS 95007-1-5:2015-07 (p. 11.6) GS 95007-3-1:2015-08 (p. 9.6.12) GS 95007-3-2:2015-09 (p. 9.6.12) GS 95007-6-1:2016-03 (p. 9.6.14)","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259edd","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Odporność na chemikalia i kwas akumulatorowy","methodology_en":"Resistance to chemicals and battery acid","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na chemikalia i kwas akumulatorowy","reference":"ISO 19642-2:2019-01 (p. 5.4.11; 6.4.10) | ISO 19642-2:2023 (p. 5.5.11; 6.5.10) | ISO 19642-3:2019-01 (p. 5.5.11) | ISO 19642-4:2019-01 (p. 5.5.11) | ISO 19642-5:2019-01 (p. 5.5.11) | ISO 19642-6:2019-01 (p. 5.5.11) | ISO 19642-7:2019-01 (p. 6.5.10) | ISO 19642-8:2019-01 (p. 6.5.10) | ISO 19642-9:2019-01 (p. 6.5.10) | ISO 19642-10:2019-01 (p. 6.5.10) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.17.3; 5.17.4; 5.17.5) | ISO 6722-2:2013-12-01 (p. 5.17) | ISO 14572:2011-10 (p. 5.17) LV 112-1:2013-04 (p. 9.8.1) LV 112-1:2014-04 (p. 9.8.1) LV 112-2:2007-11 (p. 8.9.1) LV 112-2:2013-04 (p. 9.8.1) LV 212-1:2015-01 (p. 9.8.1) LV 212-2:2015-01 (p. 9.8.1) LV 216-1:2015-07 (p. 9.8.1) LV 216-2:2017-02 (p. 9.8.1) VW 60306-1:2018-09-01 (p. 9.8.1) VW 60306-1:2021-10 (p. 9.9) VW 60306-2:2013-04 (p. 9.8.1) VW 60306-2:2021-11 (p. 9.9) VW 60306-4:2021-12 (p. 9.9) VW 75209-1:2015-01 (p. 9.8.1) VW 75209-1:2021-12 (p. 9.9) VW 75209-2:2015-01 (p. 9.8.1) VW 75209-2:2021-12 (p. 9.9) MBN LV 112-1:2016-03 (p. 9.8.1) MBN 50112-1:2023-06 (p. 12.8.2) MBN LV 112-2:2012-01 (p. 8.9.1) MBN 50112-2: 2023-05 (p. 12.9.1) MBN 50216-1:2023-07 (p. 12.9.1) MBN LV 212-1:2017-08 (p. 9.8.1) MBN 50212-1:2023-04 (p. 12.9.2) MBN LV 216-2:2017-07 (p. 9.8.1) MBN 50112-4:2024-06 (p. 12.8.2) GS 95007-1-1:2013-05 (p. 9.8.1) GS 95007-1-2:2013-05 (p. 9.8.1) GS 95007-3-1:2015-08 (p. 9.8.1) GS 95007-3-2:2015-09 (p. 9.8.1) GS 95007-6-1:2016-03 (p. 9.8.1) GS 95007-6-2:2017-04 (p. 9.8.1) Scope of accreditation No. AB 1776","norm_bases":["ISO 19642-2:2019-01 (p. 5.4.11; 6.4.10)","ISO 19642-2:2023 (p. 5.5.11; 6.5.10)","ISO 19642-3:2019-01 (p. 5.5.11)","ISO 19642-4:2019-01 (p. 5.5.11)","ISO 19642-5:2019-01 (p. 5.5.11)","ISO 19642-6:2019-01 (p. 5.5.11)","ISO 19642-7:2019-01 (p. 6.5.10)","ISO 19642-8:2019-01 (p. 6.5.10)","ISO 19642-9:2019-01 (p. 6.5.10)","ISO 19642-10:2019-01 (p. 6.5.10)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.17.3; 5.17.4; 5.17.5)","ISO 6722-2:2013-12-01 (p. 5.17)","ISO 14572:2011-10 (p. 5.17) LV 112-1:2013-04 (p. 9.8.1) LV 112-1:2014-04 (p. 9.8.1) LV 112-2:2007-11 (p. 8.9.1) LV 112-2:2013-04 (p. 9.8.1) LV 212-1:2015-01 (p. 9.8.1) LV 212-2:2015-01 (p. 9.8.1) LV 216-1:2015-07 (p. 9.8.1) LV 216-2:2017-02 (p. 9.8.1) VW 60306-1:2018-09-01 (p. 9.8.1) VW 60306-1:2021-10 (p. 9.9) VW 60306-2:2013-04 (p. 9.8.1) VW 60306-2:2021-11 (p. 9.9) VW 60306-4:2021-12 (p. 9.9) VW 75209-1:2015-01 (p. 9.8.1) VW 75209-1:2021-12 (p. 9.9) VW 75209-2:2015-01 (p. 9.8.1) VW 75209-2:2021-12 (p. 9.9) MBN LV 112-1:2016-03 (p. 9.8.1) MBN 50112-1:2023-06 (p. 12.8.2) MBN LV 112-2:2012-01 (p. 8.9.1) MBN 50112-2: 2023-05 (p. 12.9.1) MBN 50216-1:2023-07 (p. 12.9.1) MBN LV 212-1:2017-08 (p. 9.8.1) MBN 50212-1:2023-04 (p. 12.9.2) MBN LV 216-2:2017-07 (p. 9.8.1) MBN 50112-4:2024-06 (p. 12.8.2) GS 95007-1-1:2013-05 (p. 9.8.1) GS 95007-1-2:2013-05 (p. 9.8.1) GS 95007-3-1:2015-08 (p. 9.8.1) GS 95007-3-2:2015-09 (p. 9.8.1) GS 95007-6-1:2016-03 (p. 9.8.1) GS 95007-6-2:2017-04 (p. 9.8.1) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Odporność na chemikalia i kwas akumulatorowy ISO 19642-2:2019-01 (p. 5.4.11; 6.4.10) | ISO 19642-2:2023 (p. 5.5.11; 6.5.10) | ISO 19642-3:2019-01 (p. 5.5.11) | ISO 19642-4:2019-01 (p. 5.5.11) | ISO 19642-5:2019-01 (p. 5.5.11) | ISO 19642-6:2019-01 (p. 5.5.11) | ISO 19642-7:2019-01 (p. 6.5.10) | ISO 19642-8:2019-01 (p. 6.5.10) | ISO 19642-9:2019-01 (p. 6.5.10) | ISO 19642-10:2019-01 (p. 6.5.10) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.17.3; 5.17.4; 5.17.5) | ISO 6722-2:2013-12-01 (p. 5.17) | ISO 14572:2011-10 (p. 5.17) LV 112-1:2013-04 (p. 9.8.1) LV 112-1:2014-04 (p. 9.8.1) LV 112-2:2007-11 (p. 8.9.1) LV 112-2:2013-04 (p. 9.8.1) LV 212-1:2015-01 (p. 9.8.1) LV 212-2:2015-01 (p. 9.8.1) LV 216-1:2015-07 (p. 9.8.1) LV 216-2:2017-02 (p. 9.8.1) VW 60306-1:2018-09-01 (p. 9.8.1) VW 60306-1:2021-10 (p. 9.9) VW 60306-2:2013-04 (p. 9.8.1) VW 60306-2:2021-11 (p. 9.9) VW 60306-4:2021-12 (p. 9.9) VW 75209-1:2015-01 (p. 9.8.1) VW 75209-1:2021-12 (p. 9.9) VW 75209-2:2015-01 (p. 9.8.1) VW 75209-2:2021-12 (p. 9.9) MBN LV 112-1:2016-03 (p. 9.8.1) MBN 50112-1:2023-06 (p. 12.8.2) MBN LV 112-2:2012-01 (p. 8.9.1) MBN 50112-2: 2023-05 (p. 12.9.1) MBN 50216-1:2023-07 (p. 12.9.1) MBN LV 212-1:2017-08 (p. 9.8.1) MBN 50212-1:2023-04 (p. 12.9.2) MBN LV 216-2:2017-07 (p. 9.8.1) MBN 50112-4:2024-06 (p. 12.8.2) GS 95007-1-1:2013-05 (p. 9.8.1) GS 95007-1-2:2013-05 (p. 9.8.1) GS 95007-3-1:2015-08 (p. 9.8.1) GS 95007-3-2:2015-09 (p. 9.8.1) GS 95007-6-1:2016-03 (p. 9.8.1) GS 95007-6-2:2017-04 (p. 9.8.1) Scope of accreditation No. AB 1776 Kable, Cables Odpornosc na chemikalia i kwas akumulatorowy ISO 19642-2:2019-01 (p. 5.4.11; 6.4.10) | ISO 19642-2:2023 (p. 5.5.11; 6.5.10) | ISO 19642-3:2019-01 (p. 5.5.11) | ISO 19642-4:2019-01 (p. 5.5.11) | ISO 19642-5:2019-01 (p. 5.5.11) | ISO 19642-6:2019-01 (p. 5.5.11) | ISO 19642-7:2019-01 (p. 6.5.10) | ISO 19642-8:2019-01 (p. 6.5.10) | ISO 19642-9:2019-01 (p. 6.5.10) | ISO 19642-10:2019-01 (p. 6.5.10) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.17.3; 5.17.4; 5.17.5) | ISO 6722-2:2013-12-01 (p. 5.17) | ISO 14572:2011-10 (p. 5.17) LV 112-1:2013-04 (p. 9.8.1) LV 112-1:2014-04 (p. 9.8.1) LV 112-2:2007-11 (p. 8.9.1) LV 112-2:2013-04 (p. 9.8.1) LV 212-1:2015-01 (p. 9.8.1) LV 212-2:2015-01 (p. 9.8.1) LV 216-1:2015-07 (p. 9.8.1) LV 216-2:2017-02 (p. 9.8.1) VW 60306-1:2018-09-01 (p. 9.8.1) VW 60306-1:2021-10 (p. 9.9) VW 60306-2:2013-04 (p. 9.8.1) VW 60306-2:2021-11 (p. 9.9) VW 60306-4:2021-12 (p. 9.9) VW 75209-1:2015-01 (p. 9.8.1) VW 75209-1:2021-12 (p. 9.9) VW 75209-2:2015-01 (p. 9.8.1) VW 75209-2:2021-12 (p. 9.9) MBN LV 112-1:2016-03 (p. 9.8.1) MBN 50112-1:2023-06 (p. 12.8.2) MBN LV 112-2:2012-01 (p. 8.9.1) MBN 50112-2: 2023-05 (p. 12.9.1) MBN 50216-1:2023-07 (p. 12.9.1) MBN LV 212-1:2017-08 (p. 9.8.1) MBN 50212-1:2023-04 (p. 12.9.2) MBN LV 216-2:2017-07 (p. 9.8.1) MBN 50112-4:2024-06 (p. 12.8.2) GS 95007-1-1:2013-05 (p. 9.8.1) GS 95007-1-2:2013-05 (p. 9.8.1) GS 95007-3-1:2015-08 (p. 9.8.1) GS 95007-3-2:2015-09 (p. 9.8.1) GS 95007-6-1:2016-03 (p. 9.8.1) GS 95007-6-2:2017-04 (p. 9.8.1) Scope of accreditation No. AB 1776","categories":["other"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Resistance to chemicals and battery acid ISO 19642-2:2019-01 (p. 5.4.11; 6.4.10) | ISO 19642-2:2023 (p. 5.5.11; 6.5.10) | ISO 19642-3:2019-01 (p. 5.5.11) | ISO 19642-4:2019-01 (p. 5.5.11) | ISO 19642-5:2019-01 (p. 5.5.11) | ISO 19642-6:2019-01 (p. 5.5.11) | ISO 19642-7:2019-01 (p. 6.5.10) | ISO 19642-8:2019-01 (p. 6.5.10) | ISO 19642-9:2019-01 (p. 6.5.10) | ISO 19642-10:2019-01 (p. 6.5.10) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.17.3; 5.17.4; 5.17.5) | ISO 6722-2:2013-12-01 (p. 5.17) | ISO 14572:2011-10 (p. 5.17) LV 112-1:2013-04 (p. 9.8.1) LV 112-1:2014-04 (p. 9.8.1) LV 112-2:2007-11 (p. 8.9.1) LV 112-2:2013-04 (p. 9.8.1) LV 212-1:2015-01 (p. 9.8.1) LV 212-2:2015-01 (p. 9.8.1) LV 216-1:2015-07 (p. 9.8.1) LV 216-2:2017-02 (p. 9.8.1) VW 60306-1:2018-09-01 (p. 9.8.1) VW 60306-1:2021-10 (p. 9.9) VW 60306-2:2013-04 (p. 9.8.1) VW 60306-2:2021-11 (p. 9.9) VW 60306-4:2021-12 (p. 9.9) VW 75209-1:2015-01 (p. 9.8.1) VW 75209-1:2021-12 (p. 9.9) VW 75209-2:2015-01 (p. 9.8.1) VW 75209-2:2021-12 (p. 9.9) MBN LV 112-1:2016-03 (p. 9.8.1) MBN 50112-1:2023-06 (p. 12.8.2) MBN LV 112-2:2012-01 (p. 8.9.1) MBN 50112-2: 2023-05 (p. 12.9.1) MBN 50216-1:2023-07 (p. 12.9.1) MBN LV 212-1:2017-08 (p. 9.8.1) MBN 50212-1:2023-04 (p. 12.9.2) MBN LV 216-2:2017-07 (p. 9.8.1) MBN 50112-4:2024-06 (p. 12.8.2) GS 95007-1-1:2013-05 (p. 9.8.1) GS 95007-1-2:2013-05 (p. 9.8.1) GS 95007-3-1:2015-08 (p. 9.8.1) GS 95007-3-2:2015-09 (p. 9.8.1) GS 95007-6-1:2016-03 (p. 9.8.1) GS 95007-6-2:2017-04 (p. 9.8.1) Scope of accreditation No. AB 1776","search_zh":"电缆 ISO 19642-2:2019-01 (p. 5.4.11; 6.4.10) | ISO 19642-2:2023 (p. 5.5.11; 6.5.10) | ISO 19642-3:2019-01 (p. 5.5.11) | ISO 19642-4:2019-01 (p. 5.5.11) | ISO 19642-5:2019-01 (p. 5.5.11) | ISO 19642-6:2019-01 (p. 5.5.11) | ISO 19642-7:2019-01 (p. 6.5.10) | ISO 19642-8:2019-01 (p. 6.5.10) | ISO 19642-9:2019-01 (p. 6.5.10) | ISO 19642-10:2019-01 (p. 6.5.10) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.17.3; 5.17.4; 5.17.5) | ISO 6722-2:2013-12-01 (p. 5.17) | ISO 14572:2011-10 (p. 5.17) LV 112-1:2013-04 (p. 9.8.1) LV 112-1:2014-04 (p. 9.8.1) LV 112-2:2007-11 (p. 8.9.1) LV 112-2:2013-04 (p. 9.8.1) LV 212-1:2015-01 (p. 9.8.1) LV 212-2:2015-01 (p. 9.8.1) LV 216-1:2015-07 (p. 9.8.1) LV 216-2:2017-02 (p. 9.8.1) VW 60306-1:2018-09-01 (p. 9.8.1) VW 60306-1:2021-10 (p. 9.9) VW 60306-2:2013-04 (p. 9.8.1) VW 60306-2:2021-11 (p. 9.9) VW 60306-4:2021-12 (p. 9.9) VW 75209-1:2015-01 (p. 9.8.1) VW 75209-1:2021-12 (p. 9.9) VW 75209-2:2015-01 (p. 9.8.1) VW 75209-2:2021-12 (p. 9.9) MBN LV 112-1:2016-03 (p. 9.8.1) MBN 50112-1:2023-06 (p. 12.8.2) MBN LV 112-2:2012-01 (p. 8.9.1) MBN 50112-2: 2023-05 (p. 12.9.1) MBN 50216-1:2023-07 (p. 12.9.1) MBN LV 212-1:2017-08 (p. 9.8.1) MBN 50212-1:2023-04 (p. 12.9.2) MBN LV 216-2:2017-07 (p. 9.8.1) MBN 50112-4:2024-06 (p. 12.8.2) GS 95007-1-1:2013-05 (p. 9.8.1) GS 95007-1-2:2013-05 (p. 9.8.1) GS 95007-3-1:2015-08 (p. 9.8.1) GS 95007-3-2:2015-09 (p. 9.8.1) GS 95007-6-1:2016-03 (p. 9.8.1) GS 95007-6-2:2017-04 (p. 9.8.1) Scope of accreditation No. AB 1776","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ede","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Odporności na pękanie zmęczeniowe","methodology_en":"Resistance to fatigue cracking","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporności na pękanie zmęczeniowe","reference":"ISO 19642-2:2019-01 (p. 5.4.13) | ISO 19642-2:2023 (p. 5.5.13) | ISO 19642-3:2019-01 (p. 5.5.13) | ISO 19642-4:2019-01 (p. 5.5.13) | ISO 19642-5:2019-01 (p. 5.5.13) | ISO 19642-6:2019-01 (p. 5.5.13) LV 112-1:2013-04 (p. 9.6.1) LV 112-1:2014-04 (p. 9.6.1) LV 112-2:2007-11 (p. 8.7.1) LV 112-2:2013-04 (p. 9.6.1) LV 212-2:2015-01 (p. 9.6.1) LV 216-1:2015-07 (p. 9.6.1) LV 216-2:2017-02 (p. 9.6.1) VW 60306-1:2018-09-01 (p. 9.6.1) VW 60306-1:2021-10 (p. 9.7.1) VW 60306-2:2013-04 (p. 9.6.1) VW 60306-2:2021-11 (p. 9.7.1) VW 60306-4:2021-12 (p. 9.7.1) VW 75209-2:2015-01 (p. 9.6.1) VW 75210-1:2023-06 (p. 9.7.1) VW 75210-1:2024-08 (p. 9.7.1) VW 75210-2:2023-06 (p. 9.7.1) MBN LV 112-1:2016-03 (p. 9.6.1) MBN 50112-1:2023-06 (p. 12.6.1) MBN LV 112-2:2012-01 (p. 8.7.1) MBN 50112-2: 2023-05 (p. 12.7.1) MBN 50216-1:2023-07 (p. 12.7.1) MBN LV 216-2:2017-07 (p. 9.6.1) MBN 50112-4:2024-06 (p. 12.6.1) GS 95007-1-1:2013-05 (p. 9.6.1) GS 95007-1-2:2013-05 (p. 9.6.1) GS 95007-3-2:2015-09 (p. 9.6.1) GS 95007-6-1:2016-03 (p. 9.6.1) GS 95007-6-2:2017-04 (p. 9.6.1)","norm_bases":["ISO 19642-2:2019-01 (p. 5.4.13)","ISO 19642-2:2023 (p. 5.5.13)","ISO 19642-3:2019-01 (p. 5.5.13)","ISO 19642-4:2019-01 (p. 5.5.13)","ISO 19642-5:2019-01 (p. 5.5.13)","ISO 19642-6:2019-01 (p. 5.5.13) LV 112-1:2013-04 (p. 9.6.1) LV 112-1:2014-04 (p. 9.6.1) LV 112-2:2007-11 (p. 8.7.1) LV 112-2:2013-04 (p. 9.6.1) LV 212-2:2015-01 (p. 9.6.1) LV 216-1:2015-07 (p. 9.6.1) LV 216-2:2017-02 (p. 9.6.1) VW 60306-1:2018-09-01 (p. 9.6.1) VW 60306-1:2021-10 (p. 9.7.1) VW 60306-2:2013-04 (p. 9.6.1) VW 60306-2:2021-11 (p. 9.7.1) VW 60306-4:2021-12 (p. 9.7.1) VW 75209-2:2015-01 (p. 9.6.1) VW 75210-1:2023-06 (p. 9.7.1) VW 75210-1:2024-08 (p. 9.7.1) VW 75210-2:2023-06 (p. 9.7.1) MBN LV 112-1:2016-03 (p. 9.6.1) MBN 50112-1:2023-06 (p. 12.6.1) MBN LV 112-2:2012-01 (p. 8.7.1) MBN 50112-2: 2023-05 (p. 12.7.1) MBN 50216-1:2023-07 (p. 12.7.1) MBN LV 216-2:2017-07 (p. 9.6.1) MBN 50112-4:2024-06 (p. 12.6.1) GS 95007-1-1:2013-05 (p. 9.6.1) GS 95007-1-2:2013-05 (p. 9.6.1) GS 95007-3-2:2015-09 (p. 9.6.1) GS 95007-6-1:2016-03 (p. 9.6.1) GS 95007-6-2:2017-04 (p. 9.6.1)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Odporności na pękanie zmęczeniowe ISO 19642-2:2019-01 (p. 5.4.13) | ISO 19642-2:2023 (p. 5.5.13) | ISO 19642-3:2019-01 (p. 5.5.13) | ISO 19642-4:2019-01 (p. 5.5.13) | ISO 19642-5:2019-01 (p. 5.5.13) | ISO 19642-6:2019-01 (p. 5.5.13) LV 112-1:2013-04 (p. 9.6.1) LV 112-1:2014-04 (p. 9.6.1) LV 112-2:2007-11 (p. 8.7.1) LV 112-2:2013-04 (p. 9.6.1) LV 212-2:2015-01 (p. 9.6.1) LV 216-1:2015-07 (p. 9.6.1) LV 216-2:2017-02 (p. 9.6.1) VW 60306-1:2018-09-01 (p. 9.6.1) VW 60306-1:2021-10 (p. 9.7.1) VW 60306-2:2013-04 (p. 9.6.1) VW 60306-2:2021-11 (p. 9.7.1) VW 60306-4:2021-12 (p. 9.7.1) VW 75209-2:2015-01 (p. 9.6.1) VW 75210-1:2023-06 (p. 9.7.1) VW 75210-1:2024-08 (p. 9.7.1) VW 75210-2:2023-06 (p. 9.7.1) MBN LV 112-1:2016-03 (p. 9.6.1) MBN 50112-1:2023-06 (p. 12.6.1) MBN LV 112-2:2012-01 (p. 8.7.1) MBN 50112-2: 2023-05 (p. 12.7.1) MBN 50216-1:2023-07 (p. 12.7.1) MBN LV 216-2:2017-07 (p. 9.6.1) MBN 50112-4:2024-06 (p. 12.6.1) GS 95007-1-1:2013-05 (p. 9.6.1) GS 95007-1-2:2013-05 (p. 9.6.1) GS 95007-3-2:2015-09 (p. 9.6.1) GS 95007-6-1:2016-03 (p. 9.6.1) GS 95007-6-2:2017-04 (p. 9.6.1) Kable, Cables Odpornosci na pekanie zmeczeniowe ISO 19642-2:2019-01 (p. 5.4.13) | ISO 19642-2:2023 (p. 5.5.13) | ISO 19642-3:2019-01 (p. 5.5.13) | ISO 19642-4:2019-01 (p. 5.5.13) | ISO 19642-5:2019-01 (p. 5.5.13) | ISO 19642-6:2019-01 (p. 5.5.13) LV 112-1:2013-04 (p. 9.6.1) LV 112-1:2014-04 (p. 9.6.1) LV 112-2:2007-11 (p. 8.7.1) LV 112-2:2013-04 (p. 9.6.1) LV 212-2:2015-01 (p. 9.6.1) LV 216-1:2015-07 (p. 9.6.1) LV 216-2:2017-02 (p. 9.6.1) VW 60306-1:2018-09-01 (p. 9.6.1) VW 60306-1:2021-10 (p. 9.7.1) VW 60306-2:2013-04 (p. 9.6.1) VW 60306-2:2021-11 (p. 9.7.1) VW 60306-4:2021-12 (p. 9.7.1) VW 75209-2:2015-01 (p. 9.6.1) VW 75210-1:2023-06 (p. 9.7.1) VW 75210-1:2024-08 (p. 9.7.1) VW 75210-2:2023-06 (p. 9.7.1) MBN LV 112-1:2016-03 (p. 9.6.1) MBN 50112-1:2023-06 (p. 12.6.1) MBN LV 112-2:2012-01 (p. 8.7.1) MBN 50112-2: 2023-05 (p. 12.7.1) MBN 50216-1:2023-07 (p. 12.7.1) MBN LV 216-2:2017-07 (p. 9.6.1) MBN 50112-4:2024-06 (p. 12.6.1) GS 95007-1-1:2013-05 (p. 9.6.1) GS 95007-1-2:2013-05 (p. 9.6.1) GS 95007-3-2:2015-09 (p. 9.6.1) GS 95007-6-1:2016-03 (p. 9.6.1) GS 95007-6-2:2017-04 (p. 9.6.1)","categories":["other"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Resistance to fatigue cracking ISO 19642-2:2019-01 (p. 5.4.13) | ISO 19642-2:2023 (p. 5.5.13) | ISO 19642-3:2019-01 (p. 5.5.13) | ISO 19642-4:2019-01 (p. 5.5.13) | ISO 19642-5:2019-01 (p. 5.5.13) | ISO 19642-6:2019-01 (p. 5.5.13) LV 112-1:2013-04 (p. 9.6.1) LV 112-1:2014-04 (p. 9.6.1) LV 112-2:2007-11 (p. 8.7.1) LV 112-2:2013-04 (p. 9.6.1) LV 212-2:2015-01 (p. 9.6.1) LV 216-1:2015-07 (p. 9.6.1) LV 216-2:2017-02 (p. 9.6.1) VW 60306-1:2018-09-01 (p. 9.6.1) VW 60306-1:2021-10 (p. 9.7.1) VW 60306-2:2013-04 (p. 9.6.1) VW 60306-2:2021-11 (p. 9.7.1) VW 60306-4:2021-12 (p. 9.7.1) VW 75209-2:2015-01 (p. 9.6.1) VW 75210-1:2023-06 (p. 9.7.1) VW 75210-1:2024-08 (p. 9.7.1) VW 75210-2:2023-06 (p. 9.7.1) MBN LV 112-1:2016-03 (p. 9.6.1) MBN 50112-1:2023-06 (p. 12.6.1) MBN LV 112-2:2012-01 (p. 8.7.1) MBN 50112-2: 2023-05 (p. 12.7.1) MBN 50216-1:2023-07 (p. 12.7.1) MBN LV 216-2:2017-07 (p. 9.6.1) MBN 50112-4:2024-06 (p. 12.6.1) GS 95007-1-1:2013-05 (p. 9.6.1) GS 95007-1-2:2013-05 (p. 9.6.1) GS 95007-3-2:2015-09 (p. 9.6.1) GS 95007-6-1:2016-03 (p. 9.6.1) GS 95007-6-2:2017-04 (p. 9.6.1)","search_zh":"电缆 ISO 19642-2:2019-01 (p. 5.4.13) | ISO 19642-2:2023 (p. 5.5.13) | ISO 19642-3:2019-01 (p. 5.5.13) | ISO 19642-4:2019-01 (p. 5.5.13) | ISO 19642-5:2019-01 (p. 5.5.13) | ISO 19642-6:2019-01 (p. 5.5.13) LV 112-1:2013-04 (p. 9.6.1) LV 112-1:2014-04 (p. 9.6.1) LV 112-2:2007-11 (p. 8.7.1) LV 112-2:2013-04 (p. 9.6.1) LV 212-2:2015-01 (p. 9.6.1) LV 216-1:2015-07 (p. 9.6.1) LV 216-2:2017-02 (p. 9.6.1) VW 60306-1:2018-09-01 (p. 9.6.1) VW 60306-1:2021-10 (p. 9.7.1) VW 60306-2:2013-04 (p. 9.6.1) VW 60306-2:2021-11 (p. 9.7.1) VW 60306-4:2021-12 (p. 9.7.1) VW 75209-2:2015-01 (p. 9.6.1) VW 75210-1:2023-06 (p. 9.7.1) VW 75210-1:2024-08 (p. 9.7.1) VW 75210-2:2023-06 (p. 9.7.1) MBN LV 112-1:2016-03 (p. 9.6.1) MBN 50112-1:2023-06 (p. 12.6.1) MBN LV 112-2:2012-01 (p. 8.7.1) MBN 50112-2: 2023-05 (p. 12.7.1) MBN 50216-1:2023-07 (p. 12.7.1) MBN LV 216-2:2017-07 (p. 9.6.1) MBN 50112-4:2024-06 (p. 12.6.1) GS 95007-1-1:2013-05 (p. 9.6.1) GS 95007-1-2:2013-05 (p. 9.6.1) GS 95007-3-2:2015-09 (p. 9.6.1) GS 95007-6-1:2016-03 (p. 9.6.1) GS 95007-6-2:2017-04 (p. 9.6.1)","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259edf","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Odporność kabla na rozprzestrzenianie ognia","methodology_en":"Resistance of the cable to flame spread","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność kabla na rozprzestrzenianie ognia","reference":"ISO 19642-2:2019-01 (p. 5.4.15; 6.4.14) | ISO 19642-2:2023 (p. 5.5.14; 6.5.14) | ISO 19642-3:2019-01 (p. 5.5.15) | ISO 19642-4:2019-01 (p. 5.5.15) | ISO 19642-5:2019-01 (p. 5.5.15) | ISO 19642-6:2019-01 (p. 5.5.15) | ISO 19642-7:2019-01 (p. 6.5.14) | ISO 19642-8:2019-01 (p. 6.5.14) | ISO 19642-9:2019-01 (p. 6.5.14) | ISO 19642-10:2019-01 (p. 6.5.14) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.22) | ISO 6722-2:2013-12-01 (p. 5.22) | ISO 14572:2011-10 (p. 5.21) LV 112-1:2013-04 (p. 9.4) LV 112-1:2014-04 (p. 9.4) LV 112-2:2007-11 (p. 8.5) LV 112-2:2013-04 (p. 9.4) LV 122:2015-05 (p. 11.3) LV 122:2016-02 (p. 11.4) LV 212-1:2015-01 (p. 9.4) Scope of accreditation No. AB 1776","norm_bases":["ISO 19642-2:2019-01 (p. 5.4.15; 6.4.14)","ISO 19642-2:2023 (p. 5.5.14; 6.5.14)","ISO 19642-3:2019-01 (p. 5.5.15)","ISO 19642-4:2019-01 (p. 5.5.15)","ISO 19642-5:2019-01 (p. 5.5.15)","ISO 19642-6:2019-01 (p. 5.5.15)","ISO 19642-7:2019-01 (p. 6.5.14)","ISO 19642-8:2019-01 (p. 6.5.14)","ISO 19642-9:2019-01 (p. 6.5.14)","ISO 19642-10:2019-01 (p. 6.5.14)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.22)","ISO 6722-2:2013-12-01 (p. 5.22)","ISO 14572:2011-10 (p. 5.21) LV 112-1:2013-04 (p. 9.4) LV 112-1:2014-04 (p. 9.4) LV 112-2:2007-11 (p. 8.5) LV 112-2:2013-04 (p. 9.4) LV 122:2015-05 (p. 11.3) LV 122:2016-02 (p. 11.4) LV 212-1:2015-01 (p. 9.4) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Odporność kabla na rozprzestrzenianie ognia ISO 19642-2:2019-01 (p. 5.4.15; 6.4.14) | ISO 19642-2:2023 (p. 5.5.14; 6.5.14) | ISO 19642-3:2019-01 (p. 5.5.15) | ISO 19642-4:2019-01 (p. 5.5.15) | ISO 19642-5:2019-01 (p. 5.5.15) | ISO 19642-6:2019-01 (p. 5.5.15) | ISO 19642-7:2019-01 (p. 6.5.14) | ISO 19642-8:2019-01 (p. 6.5.14) | ISO 19642-9:2019-01 (p. 6.5.14) | ISO 19642-10:2019-01 (p. 6.5.14) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.22) | ISO 6722-2:2013-12-01 (p. 5.22) | ISO 14572:2011-10 (p. 5.21) LV 112-1:2013-04 (p. 9.4) LV 112-1:2014-04 (p. 9.4) LV 112-2:2007-11 (p. 8.5) LV 112-2:2013-04 (p. 9.4) LV 122:2015-05 (p. 11.3) LV 122:2016-02 (p. 11.4) LV 212-1:2015-01 (p. 9.4) Scope of accreditation No. AB 1776 Kable, Cables Odpornosc kabla na rozprzestrzenianie ognia ISO 19642-2:2019-01 (p. 5.4.15; 6.4.14) | ISO 19642-2:2023 (p. 5.5.14; 6.5.14) | ISO 19642-3:2019-01 (p. 5.5.15) | ISO 19642-4:2019-01 (p. 5.5.15) | ISO 19642-5:2019-01 (p. 5.5.15) | ISO 19642-6:2019-01 (p. 5.5.15) | ISO 19642-7:2019-01 (p. 6.5.14) | ISO 19642-8:2019-01 (p. 6.5.14) | ISO 19642-9:2019-01 (p. 6.5.14) | ISO 19642-10:2019-01 (p. 6.5.14) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.22) | ISO 6722-2:2013-12-01 (p. 5.22) | ISO 14572:2011-10 (p. 5.21) LV 112-1:2013-04 (p. 9.4) LV 112-1:2014-04 (p. 9.4) LV 112-2:2007-11 (p. 8.5) LV 112-2:2013-04 (p. 9.4) LV 122:2015-05 (p. 11.3) LV 122:2016-02 (p. 11.4) LV 212-1:2015-01 (p. 9.4) Scope of accreditation No. AB 1776","categories":["other"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Resistance of the cable to flame spread ISO 19642-2:2019-01 (p. 5.4.15; 6.4.14) | ISO 19642-2:2023 (p. 5.5.14; 6.5.14) | ISO 19642-3:2019-01 (p. 5.5.15) | ISO 19642-4:2019-01 (p. 5.5.15) | ISO 19642-5:2019-01 (p. 5.5.15) | ISO 19642-6:2019-01 (p. 5.5.15) | ISO 19642-7:2019-01 (p. 6.5.14) | ISO 19642-8:2019-01 (p. 6.5.14) | ISO 19642-9:2019-01 (p. 6.5.14) | ISO 19642-10:2019-01 (p. 6.5.14) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.22) | ISO 6722-2:2013-12-01 (p. 5.22) | ISO 14572:2011-10 (p. 5.21) LV 112-1:2013-04 (p. 9.4) LV 112-1:2014-04 (p. 9.4) LV 112-2:2007-11 (p. 8.5) LV 112-2:2013-04 (p. 9.4) LV 122:2015-05 (p. 11.3) LV 122:2016-02 (p. 11.4) LV 212-1:2015-01 (p. 9.4) Scope of accreditation No. AB 1776","search_zh":"电缆 ISO 19642-2:2019-01 (p. 5.4.15; 6.4.14) | ISO 19642-2:2023 (p. 5.5.14; 6.5.14) | ISO 19642-3:2019-01 (p. 5.5.15) | ISO 19642-4:2019-01 (p. 5.5.15) | ISO 19642-5:2019-01 (p. 5.5.15) | ISO 19642-6:2019-01 (p. 5.5.15) | ISO 19642-7:2019-01 (p. 6.5.14) | ISO 19642-8:2019-01 (p. 6.5.14) | ISO 19642-9:2019-01 (p. 6.5.14) | ISO 19642-10:2019-01 (p. 6.5.14) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.22) | ISO 6722-2:2013-12-01 (p. 5.22) | ISO 14572:2011-10 (p. 5.21) LV 112-1:2013-04 (p. 9.4) LV 112-1:2014-04 (p. 9.4) LV 112-2:2007-11 (p. 8.5) LV 112-2:2013-04 (p. 9.4) LV 122:2015-05 (p. 11.3) LV 122:2016-02 (p. 11.4) LV 212-1:2015-01 (p. 9.4) Scope of accreditation No. AB 1776","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ee0","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"","methodology_en":null,"parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"","reference":"LV 216-1:2015-07 (p. 9.4) LV 212-2:2015-01 (p. 9.4) LV 216-2:2017-02 (p. 9.4) VW 60306-1:2018-09-01 (p. 9.4) VW 60306-1:2021-10 (p. 9.5) VW 60306-2:2013-04 (p. 9.4) VW 60306-2:2021-11 (p. 9.5) VW 60306-4:2021-12 (p. 9.5) VW 75205:2019-11 (p. 11.3) VW 75205:2023-05 (p. 11.3) VW 75205:2024-04 (p. 11.4) VW 75209-1:2015-01 (p. 9.4) VW 75209-1:2021-12 (p. 9.5) VW 75209-2:2015-01 (p. 9.4) VW 75209-2:2021-12 (p. 9.4.4) VW 75210-1:2023-06 (p. 9.5) VW 75210-1:2024-08 (p. 9.5) VW 75210-2:2023-06 (p. 9.5) MBN LV 112-1:2016-03 (p. 9.4) MBN 50112-1:2023-06 (p. 12.4) MBN LV 112-2:2012-01 (p. 8.5) MBN 50112-2:2023-05 (p. 12.5) MBN 50216-1:2023-07 (p. 12.5) MBN LV 122:2017-06 (p. 11.4) MBN 50122:2023-07 (p. 13.4) MBN LV 212-1:2017-08 (p. 9.4) MBN 50212-1:2023-04 (p. 12.5) MBN LV 216-2:2017-07 (p. 9.4) MBN 50112-4:2024-06 (p. 12.4) GS 95007-1-1:2013-05 (p. 9.4) GS 95007-1-2:2013-05 (p. 9.4) GS 95007-1-5:2015-07 (p. 11.3) GS 95007-3-1:2015-08 (p. 9.4) GS 95007-3-2:2015-09 (p. 9.4) GS 95007-6-1:2016-03 (p. 9.4) GS 95007-6-2:2017-04 (p. 9.4) Scope of accreditation No. AB 1776","norm_bases":["LV 216-1:2015-07 (p. 9.4) LV 212-2:2015-01 (p. 9.4) LV 216-2:2017-02 (p. 9.4) VW 60306-1:2018-09-01 (p. 9.4) VW 60306-1:2021-10 (p. 9.5) VW 60306-2:2013-04 (p. 9.4) VW 60306-2:2021-11 (p. 9.5) VW 60306-4:2021-12 (p. 9.5) VW 75205:2019-11 (p. 11.3) VW 75205:2023-05 (p. 11.3) VW 75205:2024-04 (p. 11.4) VW 75209-1:2015-01 (p. 9.4) VW 75209-1:2021-12 (p. 9.5) VW 75209-2:2015-01 (p. 9.4) VW 75209-2:2021-12 (p. 9.4.4) VW 75210-1:2023-06 (p. 9.5) VW 75210-1:2024-08 (p. 9.5) VW 75210-2:2023-06 (p. 9.5) MBN LV 112-1:2016-03 (p. 9.4) MBN 50112-1:2023-06 (p. 12.4) MBN LV 112-2:2012-01 (p. 8.5) MBN 50112-2:2023-05 (p. 12.5) MBN 50216-1:2023-07 (p. 12.5) MBN LV 122:2017-06 (p. 11.4) MBN 50122:2023-07 (p. 13.4) MBN LV 212-1:2017-08 (p. 9.4) MBN 50212-1:2023-04 (p. 12.5) MBN LV 216-2:2017-07 (p. 9.4) MBN 50112-4:2024-06 (p. 12.4) GS 95007-1-1:2013-05 (p. 9.4) GS 95007-1-2:2013-05 (p. 9.4) GS 95007-1-5:2015-07 (p. 11.3) GS 95007-3-1:2015-08 (p. 9.4) GS 95007-3-2:2015-09 (p. 9.4) GS 95007-6-1:2016-03 (p. 9.4) GS 95007-6-2:2017-04 (p. 9.4) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables LV 216-1:2015-07 (p. 9.4) LV 212-2:2015-01 (p. 9.4) LV 216-2:2017-02 (p. 9.4) VW 60306-1:2018-09-01 (p. 9.4) VW 60306-1:2021-10 (p. 9.5) VW 60306-2:2013-04 (p. 9.4) VW 60306-2:2021-11 (p. 9.5) VW 60306-4:2021-12 (p. 9.5) VW 75205:2019-11 (p. 11.3) VW 75205:2023-05 (p. 11.3) VW 75205:2024-04 (p. 11.4) VW 75209-1:2015-01 (p. 9.4) VW 75209-1:2021-12 (p. 9.5) VW 75209-2:2015-01 (p. 9.4) VW 75209-2:2021-12 (p. 9.4.4) VW 75210-1:2023-06 (p. 9.5) VW 75210-1:2024-08 (p. 9.5) VW 75210-2:2023-06 (p. 9.5) MBN LV 112-1:2016-03 (p. 9.4) MBN 50112-1:2023-06 (p. 12.4) MBN LV 112-2:2012-01 (p. 8.5) MBN 50112-2:2023-05 (p. 12.5) MBN 50216-1:2023-07 (p. 12.5) MBN LV 122:2017-06 (p. 11.4) MBN 50122:2023-07 (p. 13.4) MBN LV 212-1:2017-08 (p. 9.4) MBN 50212-1:2023-04 (p. 12.5) MBN LV 216-2:2017-07 (p. 9.4) MBN 50112-4:2024-06 (p. 12.4) GS 95007-1-1:2013-05 (p. 9.4) GS 95007-1-2:2013-05 (p. 9.4) GS 95007-1-5:2015-07 (p. 11.3) GS 95007-3-1:2015-08 (p. 9.4) GS 95007-3-2:2015-09 (p. 9.4) GS 95007-6-1:2016-03 (p. 9.4) GS 95007-6-2:2017-04 (p. 9.4) Scope of accreditation No. AB 1776 Kable, Cables LV 216-1:2015-07 (p. 9.4) LV 212-2:2015-01 (p. 9.4) LV 216-2:2017-02 (p. 9.4) VW 60306-1:2018-09-01 (p. 9.4) VW 60306-1:2021-10 (p. 9.5) VW 60306-2:2013-04 (p. 9.4) VW 60306-2:2021-11 (p. 9.5) VW 60306-4:2021-12 (p. 9.5) VW 75205:2019-11 (p. 11.3) VW 75205:2023-05 (p. 11.3) VW 75205:2024-04 (p. 11.4) VW 75209-1:2015-01 (p. 9.4) VW 75209-1:2021-12 (p. 9.5) VW 75209-2:2015-01 (p. 9.4) VW 75209-2:2021-12 (p. 9.4.4) VW 75210-1:2023-06 (p. 9.5) VW 75210-1:2024-08 (p. 9.5) VW 75210-2:2023-06 (p. 9.5) MBN LV 112-1:2016-03 (p. 9.4) MBN 50112-1:2023-06 (p. 12.4) MBN LV 112-2:2012-01 (p. 8.5) MBN 50112-2:2023-05 (p. 12.5) MBN 50216-1:2023-07 (p. 12.5) MBN LV 122:2017-06 (p. 11.4) MBN 50122:2023-07 (p. 13.4) MBN LV 212-1:2017-08 (p. 9.4) MBN 50212-1:2023-04 (p. 12.5) MBN LV 216-2:2017-07 (p. 9.4) MBN 50112-4:2024-06 (p. 12.4) GS 95007-1-1:2013-05 (p. 9.4) GS 95007-1-2:2013-05 (p. 9.4) GS 95007-1-5:2015-07 (p. 11.3) GS 95007-3-1:2015-08 (p. 9.4) GS 95007-3-2:2015-09 (p. 9.4) GS 95007-6-1:2016-03 (p. 9.4) GS 95007-6-2:2017-04 (p. 9.4) Scope of accreditation No. AB 1776","categories":["other"],"row_index":72,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables LV 216-1:2015-07 (p. 9.4) LV 212-2:2015-01 (p. 9.4) LV 216-2:2017-02 (p. 9.4) VW 60306-1:2018-09-01 (p. 9.4) VW 60306-1:2021-10 (p. 9.5) VW 60306-2:2013-04 (p. 9.4) VW 60306-2:2021-11 (p. 9.5) VW 60306-4:2021-12 (p. 9.5) VW 75205:2019-11 (p. 11.3) VW 75205:2023-05 (p. 11.3) VW 75205:2024-04 (p. 11.4) VW 75209-1:2015-01 (p. 9.4) VW 75209-1:2021-12 (p. 9.5) VW 75209-2:2015-01 (p. 9.4) VW 75209-2:2021-12 (p. 9.4.4) VW 75210-1:2023-06 (p. 9.5) VW 75210-1:2024-08 (p. 9.5) VW 75210-2:2023-06 (p. 9.5) MBN LV 112-1:2016-03 (p. 9.4) MBN 50112-1:2023-06 (p. 12.4) MBN LV 112-2:2012-01 (p. 8.5) MBN 50112-2:2023-05 (p. 12.5) MBN 50216-1:2023-07 (p. 12.5) MBN LV 122:2017-06 (p. 11.4) MBN 50122:2023-07 (p. 13.4) MBN LV 212-1:2017-08 (p. 9.4) MBN 50212-1:2023-04 (p. 12.5) MBN LV 216-2:2017-07 (p. 9.4) MBN 50112-4:2024-06 (p. 12.4) GS 95007-1-1:2013-05 (p. 9.4) GS 95007-1-2:2013-05 (p. 9.4) GS 95007-1-5:2015-07 (p. 11.3) GS 95007-3-1:2015-08 (p. 9.4) GS 95007-3-2:2015-09 (p. 9.4) GS 95007-6-1:2016-03 (p. 9.4) GS 95007-6-2:2017-04 (p. 9.4) Scope of accreditation No. AB 1776","search_zh":"电缆 LV 216-1:2015-07 (p. 9.4) LV 212-2:2015-01 (p. 9.4) LV 216-2:2017-02 (p. 9.4) VW 60306-1:2018-09-01 (p. 9.4) VW 60306-1:2021-10 (p. 9.5) VW 60306-2:2013-04 (p. 9.4) VW 60306-2:2021-11 (p. 9.5) VW 60306-4:2021-12 (p. 9.5) VW 75205:2019-11 (p. 11.3) VW 75205:2023-05 (p. 11.3) VW 75205:2024-04 (p. 11.4) VW 75209-1:2015-01 (p. 9.4) VW 75209-1:2021-12 (p. 9.5) VW 75209-2:2015-01 (p. 9.4) VW 75209-2:2021-12 (p. 9.4.4) VW 75210-1:2023-06 (p. 9.5) VW 75210-1:2024-08 (p. 9.5) VW 75210-2:2023-06 (p. 9.5) MBN LV 112-1:2016-03 (p. 9.4) MBN 50112-1:2023-06 (p. 12.4) MBN LV 112-2:2012-01 (p. 8.5) MBN 50112-2:2023-05 (p. 12.5) MBN 50216-1:2023-07 (p. 12.5) MBN LV 122:2017-06 (p. 11.4) MBN 50122:2023-07 (p. 13.4) MBN LV 212-1:2017-08 (p. 9.4) MBN 50212-1:2023-04 (p. 12.5) MBN LV 216-2:2017-07 (p. 9.4) MBN 50112-4:2024-06 (p. 12.4) GS 95007-1-1:2013-05 (p. 9.4) GS 95007-1-2:2013-05 (p. 9.4) GS 95007-1-5:2015-07 (p. 11.3) GS 95007-3-1:2015-08 (p. 9.4) GS 95007-3-2:2015-09 (p. 9.4) GS 95007-6-1:2016-03 (p. 9.4) GS 95007-6-2:2017-04 (p. 9.4) Scope of accreditation No. AB 1776","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ee1","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Owalność kabla","methodology_en":"Cable ovality","parameters":[{"name":"Średnica zewnętrzna kabla ≤ 25 mm Ovality Range: Cable outer diameter ≤ 25 mm"}],"parameters_en":[{"name":"Ovality Range: Cable outer diameter ≤ 25 mm"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Owalność kabla\nŚrednica zewnętrzna kabla ≤ 25 mm Ovality Range: Cable outer diameter ≤ 25 mm","reference":"ISO 19642-2:2019-01 (p. 6.1.2) | ISO 19642-2:2023 (p. 6.2.2) | ISO 19642-7:2019-01 (p. 6.2.2) | ISO 19642-8 2019-01 (p. 6.2.2) | ISO 19642-9:2019-01 (p. 6.2.2) | ISO 19642-10:2019-01 (p. 6.2.2) | ISO 14572:2011-10 (p. 5.2) LV 212-1:2015-01 (p. 9.1.1) LV 212-2:2015-01 (p. 9.1.1) LV 216-2:2017-02 (p. 9.1.1) VW 75209-1:2015-01 (p. 9.1.1) VW 75209-1:2021-12 (p. 9.2.2) VW 75209-2:2015-01 (p. 9.1.1) VW 75209-2:2021-12 (p. 9.2.2) VW 75210-1:2024-08 (p. 9.2.2) VW 75210-2:2023-06 (p. 9.2.1) MBN LV 212-1:2017-08 (p. 9.1.1) MBN 50212-1:2023-04 (p. 12.2.2) MBN LV 216-2:2017-07 (p. 9.1.1) GS 95007-3-1:2015-08 (p. 9.1.1) GS 95007-3-2:2015-09 (p. 9.1.1) GS 95007-6-2:2017-04 (p. 9.1.1)","norm_bases":["ISO 19642-2:2019-01 (p. 6.1.2)","ISO 19642-2:2023 (p. 6.2.2)","ISO 19642-7:2019-01 (p. 6.2.2)","ISO 19642-8 2019-01 (p. 6.2.2)","ISO 19642-9:2019-01 (p. 6.2.2)","ISO 19642-10:2019-01 (p. 6.2.2)","ISO 14572:2011-10 (p. 5.2) LV 212-1:2015-01 (p. 9.1.1) LV 212-2:2015-01 (p. 9.1.1) LV 216-2:2017-02 (p. 9.1.1) VW 75209-1:2015-01 (p. 9.1.1) VW 75209-1:2021-12 (p. 9.2.2) VW 75209-2:2015-01 (p. 9.1.1) VW 75209-2:2021-12 (p. 9.2.2) VW 75210-1:2024-08 (p. 9.2.2) VW 75210-2:2023-06 (p. 9.2.1) MBN LV 212-1:2017-08 (p. 9.1.1) MBN 50212-1:2023-04 (p. 12.2.2) MBN LV 216-2:2017-07 (p. 9.1.1) GS 95007-3-1:2015-08 (p. 9.1.1) GS 95007-3-2:2015-09 (p. 9.1.1) GS 95007-6-2:2017-04 (p. 9.1.1)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Owalność kabla\nŚrednica zewnętrzna kabla ≤ 25 mm Ovality Range: Cable outer diameter ≤ 25 mm ISO 19642-2:2019-01 (p. 6.1.2) | ISO 19642-2:2023 (p. 6.2.2) | ISO 19642-7:2019-01 (p. 6.2.2) | ISO 19642-8 2019-01 (p. 6.2.2) | ISO 19642-9:2019-01 (p. 6.2.2) | ISO 19642-10:2019-01 (p. 6.2.2) | ISO 14572:2011-10 (p. 5.2) LV 212-1:2015-01 (p. 9.1.1) LV 212-2:2015-01 (p. 9.1.1) LV 216-2:2017-02 (p. 9.1.1) VW 75209-1:2015-01 (p. 9.1.1) VW 75209-1:2021-12 (p. 9.2.2) VW 75209-2:2015-01 (p. 9.1.1) VW 75209-2:2021-12 (p. 9.2.2) VW 75210-1:2024-08 (p. 9.2.2) VW 75210-2:2023-06 (p. 9.2.1) MBN LV 212-1:2017-08 (p. 9.1.1) MBN 50212-1:2023-04 (p. 12.2.2) MBN LV 216-2:2017-07 (p. 9.1.1) GS 95007-3-1:2015-08 (p. 9.1.1) GS 95007-3-2:2015-09 (p. 9.1.1) GS 95007-6-2:2017-04 (p. 9.1.1) Kable, Cables Owalnosc kabla\nSrednica zewnetrzna kabla ≤ 25 mm Ovality Range: Cable outer diameter ≤ 25 mm ISO 19642-2:2019-01 (p. 6.1.2) | ISO 19642-2:2023 (p. 6.2.2) | ISO 19642-7:2019-01 (p. 6.2.2) | ISO 19642-8 2019-01 (p. 6.2.2) | ISO 19642-9:2019-01 (p. 6.2.2) | ISO 19642-10:2019-01 (p. 6.2.2) | ISO 14572:2011-10 (p. 5.2) LV 212-1:2015-01 (p. 9.1.1) LV 212-2:2015-01 (p. 9.1.1) LV 216-2:2017-02 (p. 9.1.1) VW 75209-1:2015-01 (p. 9.1.1) VW 75209-1:2021-12 (p. 9.2.2) VW 75209-2:2015-01 (p. 9.1.1) VW 75209-2:2021-12 (p. 9.2.2) VW 75210-1:2024-08 (p. 9.2.2) VW 75210-2:2023-06 (p. 9.2.1) MBN LV 212-1:2017-08 (p. 9.1.1) MBN 50212-1:2023-04 (p. 12.2.2) MBN LV 216-2:2017-07 (p. 9.1.1) GS 95007-3-1:2015-08 (p. 9.1.1) GS 95007-3-2:2015-09 (p. 9.1.1) GS 95007-6-2:2017-04 (p. 9.1.1)","categories":["other"],"row_index":73,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Cable ovality Ovality Range: Cable outer diameter ≤ 25 mm ISO 19642-2:2019-01 (p. 6.1.2) | ISO 19642-2:2023 (p. 6.2.2) | ISO 19642-7:2019-01 (p. 6.2.2) | ISO 19642-8 2019-01 (p. 6.2.2) | ISO 19642-9:2019-01 (p. 6.2.2) | ISO 19642-10:2019-01 (p. 6.2.2) | ISO 14572:2011-10 (p. 5.2) LV 212-1:2015-01 (p. 9.1.1) LV 212-2:2015-01 (p. 9.1.1) LV 216-2:2017-02 (p. 9.1.1) VW 75209-1:2015-01 (p. 9.1.1) VW 75209-1:2021-12 (p. 9.2.2) VW 75209-2:2015-01 (p. 9.1.1) VW 75209-2:2021-12 (p. 9.2.2) VW 75210-1:2024-08 (p. 9.2.2) VW 75210-2:2023-06 (p. 9.2.1) MBN LV 212-1:2017-08 (p. 9.1.1) MBN 50212-1:2023-04 (p. 12.2.2) MBN LV 216-2:2017-07 (p. 9.1.1) GS 95007-3-1:2015-08 (p. 9.1.1) GS 95007-3-2:2015-09 (p. 9.1.1) GS 95007-6-2:2017-04 (p. 9.1.1)","search_zh":"电缆 ISO 19642-2:2019-01 (p. 6.1.2) | ISO 19642-2:2023 (p. 6.2.2) | ISO 19642-7:2019-01 (p. 6.2.2) | ISO 19642-8 2019-01 (p. 6.2.2) | ISO 19642-9:2019-01 (p. 6.2.2) | ISO 19642-10:2019-01 (p. 6.2.2) | ISO 14572:2011-10 (p. 5.2) LV 212-1:2015-01 (p. 9.1.1) LV 212-2:2015-01 (p. 9.1.1) LV 216-2:2017-02 (p. 9.1.1) VW 75209-1:2015-01 (p. 9.1.1) VW 75209-1:2021-12 (p. 9.2.2) VW 75209-2:2015-01 (p. 9.1.1) VW 75209-2:2021-12 (p. 9.2.2) VW 75210-1:2024-08 (p. 9.2.2) VW 75210-2:2023-06 (p. 9.2.1) MBN LV 212-1:2017-08 (p. 9.1.1) MBN 50212-1:2023-04 (p. 12.2.2) MBN LV 216-2:2017-07 (p. 9.1.1) GS 95007-3-1:2015-08 (p. 9.1.1) GS 95007-3-2:2015-09 (p. 9.1.1) GS 95007-6-2:2017-04 (p. 9.1.1)","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ee2","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Ciągłość elektryczna, Electrical continuity","methodology_en":"Electrical continuity","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciągłość elektryczna, Electrical continuity","reference":"ISO 19642-2:2019-01 (p. 6.2.1) | ISO 19642-2:2023 (p. 6.3.1) | ISO 19642-7:2019-01 (p. 6.3.1) | ISO 19642-8:2019-01 (p. 6.3.1) | ISO 19642-9:2019-01 (p. 6.3.1) | ISO 19642-10:2019-01 (p. 6.3.1) | ISO 14572:2011-10 (p. 5.4) Scope of accreditation No. AB 1776","norm_bases":["ISO 19642-2:2019-01 (p. 6.2.1)","ISO 19642-2:2023 (p. 6.3.1)","ISO 19642-7:2019-01 (p. 6.3.1)","ISO 19642-8:2019-01 (p. 6.3.1)","ISO 19642-9:2019-01 (p. 6.3.1)","ISO 19642-10:2019-01 (p. 6.3.1)","ISO 14572:2011-10 (p. 5.4) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Ciągłość elektryczna, Electrical continuity ISO 19642-2:2019-01 (p. 6.2.1) | ISO 19642-2:2023 (p. 6.3.1) | ISO 19642-7:2019-01 (p. 6.3.1) | ISO 19642-8:2019-01 (p. 6.3.1) | ISO 19642-9:2019-01 (p. 6.3.1) | ISO 19642-10:2019-01 (p. 6.3.1) | ISO 14572:2011-10 (p. 5.4) Scope of accreditation No. AB 1776 Kable, Cables Ciaglosc elektryczna, Electrical continuity ISO 19642-2:2019-01 (p. 6.2.1) | ISO 19642-2:2023 (p. 6.3.1) | ISO 19642-7:2019-01 (p. 6.3.1) | ISO 19642-8:2019-01 (p. 6.3.1) | ISO 19642-9:2019-01 (p. 6.3.1) | ISO 19642-10:2019-01 (p. 6.3.1) | ISO 14572:2011-10 (p. 5.4) Scope of accreditation No. AB 1776","categories":["other"],"row_index":74,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Electrical continuity ISO 19642-2:2019-01 (p. 6.2.1) | ISO 19642-2:2023 (p. 6.3.1) | ISO 19642-7:2019-01 (p. 6.3.1) | ISO 19642-8:2019-01 (p. 6.3.1) | ISO 19642-9:2019-01 (p. 6.3.1) | ISO 19642-10:2019-01 (p. 6.3.1) | ISO 14572:2011-10 (p. 5.4) Scope of accreditation No. AB 1776","search_zh":"电缆 ISO 19642-2:2019-01 (p. 6.2.1) | ISO 19642-2:2023 (p. 6.3.1) | ISO 19642-7:2019-01 (p. 6.3.1) | ISO 19642-8:2019-01 (p. 6.3.1) | ISO 19642-9:2019-01 (p. 6.3.1) | ISO 19642-10:2019-01 (p. 6.3.1) | ISO 14572:2011-10 (p. 5.4) Scope of accreditation No. AB 1776","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ee3","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Badania wizualne:","methodology_en":"Visual examinations:","parameters":[{"name":"kolor izolacji / powłoki"},{"name":"test wizualny kabla"},{"name":"kierunek skrętu żyły i kabli skręconych"},{"name":"Tablice kolorów RAL","range":"9005, 5017, 8003,"},{"name":"Zakres","range":"7000, 6018, 2003, 3000, 4005, 1013, 1021,"},{"name":"5015, 1001, 6016, 3015"}],"parameters_en":[{"name":"colour of insulation / sheath"},{"name":"visual test of the cable"},{"name":"lay direction of the conductor and stranded cables"},{"name":"RAL colour charts","range":"9005, 5017, 8003,"},{"name":"Range","range":"7000, 6018, 2003, 3000, 4005, 1013, 1021,"},{"name":"5015, 1001, 6016, 3015"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badania wizualne:\nZakres:\nkolor izolacji / powłoki\ntest wizualny kabla\nkierunek skrętu żyły i kabli skręconych\nTablice kolorów RAL 9005, 5017, 8003,\nZakres 7000, 6018, 2003, 3000, 4005, 1013, 1021,\n5015, 1001, 6016, 3015","reference":"LV 112-1:2013-04 (p. 7.3; 7.4.1) LV 112-2:2013-04 (p. 7.3; 7.4.1) LV 122:2015-05 (p. 9.4.1; 11.1.4) LV 122:2016-02 (p. 9.4.1; 11.2.4) LV 212-1:2015-01 (p. 7.3; 7.4.1) LV 212-2:2015-01 (p. 7.3; 7.4.1) LV 216-1:2015-07 (p. 7.3; 7.5.1) LV 216-2:2017-02 (p. 7.3; 7.5.1) VW 60306-1:2018-09-01 (p. 7.3; 7.4.1) VW 60306-1:2021-10 (p. 7.2; 7.3; 7.4.1) VW 60306-2:2013-04 (p. 7.3; 7.4.1) VW 60306-2:2021-11 (p. 7.3; 7.4.1) VW 60306-4:2021-12 (p. 7.2; 7.3; 7.4.1) VW 75205:2019-11 (p. 9.4.1; 11.1.4) VW 75205:2023-05 (p. 9.2; 9.4.1; 11.1.4) VW 75205:2024-04 (p. 11.2.5) VW 75209-1:2015-01 (p. 7.3; 7.4.1) VW 75209-1:2021-12 (p. 7.2; 7.3; 7.4.1) VW 75209-2:2015-01 (p. 7.3; 7.4.1) VW 75209-2:2021-12 (p. 7.2; 7.3; 7.4.1) VW 75210-1:2023-06 (p. 7.2; 7.3; 7.4.1) VW 75210-1:2024-08 (p. 7.2; 7.3; 7.4.1) VW 75210-2:2023-06 (p. 7.2; 7.3; 7.4.1) MBN LV 112-1:2016-03 (p. 7.3; 7.4.1) MBN 50112-1:2023-06 (p. 10.3; 10.4.2) MBN 50112-2: 2023-05 (p. 10.3; 10.4.1) MBN 50216-1:2023-07 (p. 10.3; 10.5.2) MBN LV 212-1:2017-08 (p. 7.3; 7.4.1) MBN 50212-1:2023-04 (p. 10.2; 10.3.1; 10.3.2; 10.4.2) MBN LV 122:2017-06 (p. 9.4.1; 11.2.4) MBN 50122:2023-07 (p. 11.4.1; 13.2.5) MBN LV 216-2:2017-07 (p. 7.3; 7.5.1) MBN 50112-4:2024-06 (p. 10.3; 10.4.2) GS 95007-1-1:2013-05 (p. 7.3; 7.4.1) GS 95007-1-2:2013-05 (p. 7.3; 7.4.1) GS 95007-1-5:2015-07 (p. 9.4.1; 11.1.4) GS 95007-3-1:2015-08 (p. 7.3; 7.4.1) GS 95007-3-2:2015-09 (p. 7.3; 7.4.1) GS 95007-6-1:2016-03 (p. 7.3; 7.5.1) GS 95007-6-2:2017-04 (p. 7.3; 7.5.1) | ISO 14572:2011-10 (p. 4.7) Scope of accreditation No. AB 1776","norm_bases":["LV 112-1:2013-04 (p. 7.3; 7.4.1) LV 112-2:2013-04 (p. 7.3; 7.4.1) LV 122:2015-05 (p. 9.4.1; 11.1.4) LV 122:2016-02 (p. 9.4.1; 11.2.4) LV 212-1:2015-01 (p. 7.3; 7.4.1) LV 212-2:2015-01 (p. 7.3; 7.4.1) LV 216-1:2015-07 (p. 7.3; 7.5.1) LV 216-2:2017-02 (p. 7.3; 7.5.1) VW 60306-1:2018-09-01 (p. 7.3; 7.4.1) VW 60306-1:2021-10 (p. 7.2; 7.3; 7.4.1) VW 60306-2:2013-04 (p. 7.3; 7.4.1) VW 60306-2:2021-11 (p. 7.3; 7.4.1) VW 60306-4:2021-12 (p. 7.2; 7.3; 7.4.1) VW 75205:2019-11 (p. 9.4.1; 11.1.4) VW 75205:2023-05 (p. 9.2; 9.4.1; 11.1.4) VW 75205:2024-04 (p. 11.2.5) VW 75209-1:2015-01 (p. 7.3; 7.4.1) VW 75209-1:2021-12 (p. 7.2; 7.3; 7.4.1) VW 75209-2:2015-01 (p. 7.3; 7.4.1) VW 75209-2:2021-12 (p. 7.2; 7.3; 7.4.1) VW 75210-1:2023-06 (p. 7.2; 7.3; 7.4.1) VW 75210-1:2024-08 (p. 7.2; 7.3; 7.4.1) VW 75210-2:2023-06 (p. 7.2; 7.3; 7.4.1) MBN LV 112-1:2016-03 (p. 7.3; 7.4.1) MBN 50112-1:2023-06 (p. 10.3; 10.4.2) MBN 50112-2: 2023-05 (p. 10.3; 10.4.1) MBN 50216-1:2023-07 (p. 10.3; 10.5.2) MBN LV 212-1:2017-08 (p. 7.3; 7.4.1) MBN 50212-1:2023-04 (p. 10.2; 10.3.1; 10.3.2; 10.4.2) MBN LV 122:2017-06 (p. 9.4.1; 11.2.4) MBN 50122:2023-07 (p. 11.4.1; 13.2.5) MBN LV 216-2:2017-07 (p. 7.3; 7.5.1) MBN 50112-4:2024-06 (p. 10.3; 10.4.2) GS 95007-1-1:2013-05 (p. 7.3; 7.4.1) GS 95007-1-2:2013-05 (p. 7.3; 7.4.1) GS 95007-1-5:2015-07 (p. 9.4.1; 11.1.4) GS 95007-3-1:2015-08 (p. 7.3; 7.4.1) GS 95007-3-2:2015-09 (p. 7.3; 7.4.1) GS 95007-6-1:2016-03 (p. 7.3; 7.5.1) GS 95007-6-2:2017-04 (p. 7.3; 7.5.1)","ISO 14572:2011-10 (p. 4.7) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Badania wizualne:\nZakres:\nkolor izolacji / powłoki\ntest wizualny kabla\nkierunek skrętu żyły i kabli skręconych\nTablice kolorów RAL 9005, 5017, 8003,\nZakres 7000, 6018, 2003, 3000, 4005, 1013, 1021,\n5015, 1001, 6016, 3015 LV 112-1:2013-04 (p. 7.3; 7.4.1) LV 112-2:2013-04 (p. 7.3; 7.4.1) LV 122:2015-05 (p. 9.4.1; 11.1.4) LV 122:2016-02 (p. 9.4.1; 11.2.4) LV 212-1:2015-01 (p. 7.3; 7.4.1) LV 212-2:2015-01 (p. 7.3; 7.4.1) LV 216-1:2015-07 (p. 7.3; 7.5.1) LV 216-2:2017-02 (p. 7.3; 7.5.1) VW 60306-1:2018-09-01 (p. 7.3; 7.4.1) VW 60306-1:2021-10 (p. 7.2; 7.3; 7.4.1) VW 60306-2:2013-04 (p. 7.3; 7.4.1) VW 60306-2:2021-11 (p. 7.3; 7.4.1) VW 60306-4:2021-12 (p. 7.2; 7.3; 7.4.1) VW 75205:2019-11 (p. 9.4.1; 11.1.4) VW 75205:2023-05 (p. 9.2; 9.4.1; 11.1.4) VW 75205:2024-04 (p. 11.2.5) VW 75209-1:2015-01 (p. 7.3; 7.4.1) VW 75209-1:2021-12 (p. 7.2; 7.3; 7.4.1) VW 75209-2:2015-01 (p. 7.3; 7.4.1) VW 75209-2:2021-12 (p. 7.2; 7.3; 7.4.1) VW 75210-1:2023-06 (p. 7.2; 7.3; 7.4.1) VW 75210-1:2024-08 (p. 7.2; 7.3; 7.4.1) VW 75210-2:2023-06 (p. 7.2; 7.3; 7.4.1) MBN LV 112-1:2016-03 (p. 7.3; 7.4.1) MBN 50112-1:2023-06 (p. 10.3; 10.4.2) MBN 50112-2: 2023-05 (p. 10.3; 10.4.1) MBN 50216-1:2023-07 (p. 10.3; 10.5.2) MBN LV 212-1:2017-08 (p. 7.3; 7.4.1) MBN 50212-1:2023-04 (p. 10.2; 10.3.1; 10.3.2; 10.4.2) MBN LV 122:2017-06 (p. 9.4.1; 11.2.4) MBN 50122:2023-07 (p. 11.4.1; 13.2.5) MBN LV 216-2:2017-07 (p. 7.3; 7.5.1) MBN 50112-4:2024-06 (p. 10.3; 10.4.2) GS 95007-1-1:2013-05 (p. 7.3; 7.4.1) GS 95007-1-2:2013-05 (p. 7.3; 7.4.1) GS 95007-1-5:2015-07 (p. 9.4.1; 11.1.4) GS 95007-3-1:2015-08 (p. 7.3; 7.4.1) GS 95007-3-2:2015-09 (p. 7.3; 7.4.1) GS 95007-6-1:2016-03 (p. 7.3; 7.5.1) GS 95007-6-2:2017-04 (p. 7.3; 7.5.1) | ISO 14572:2011-10 (p. 4.7) Scope of accreditation No. AB 1776 Kable, Cables Badania wizualne:\nZakres:\nkolor izolacji / powloki\ntest wizualny kabla\nkierunek skretu zyly i kabli skreconych\nTablice kolorow RAL 9005, 5017, 8003,\nZakres 7000, 6018, 2003, 3000, 4005, 1013, 1021,\n5015, 1001, 6016, 3015 LV 112-1:2013-04 (p. 7.3; 7.4.1) LV 112-2:2013-04 (p. 7.3; 7.4.1) LV 122:2015-05 (p. 9.4.1; 11.1.4) LV 122:2016-02 (p. 9.4.1; 11.2.4) LV 212-1:2015-01 (p. 7.3; 7.4.1) LV 212-2:2015-01 (p. 7.3; 7.4.1) LV 216-1:2015-07 (p. 7.3; 7.5.1) LV 216-2:2017-02 (p. 7.3; 7.5.1) VW 60306-1:2018-09-01 (p. 7.3; 7.4.1) VW 60306-1:2021-10 (p. 7.2; 7.3; 7.4.1) VW 60306-2:2013-04 (p. 7.3; 7.4.1) VW 60306-2:2021-11 (p. 7.3; 7.4.1) VW 60306-4:2021-12 (p. 7.2; 7.3; 7.4.1) VW 75205:2019-11 (p. 9.4.1; 11.1.4) VW 75205:2023-05 (p. 9.2; 9.4.1; 11.1.4) VW 75205:2024-04 (p. 11.2.5) VW 75209-1:2015-01 (p. 7.3; 7.4.1) VW 75209-1:2021-12 (p. 7.2; 7.3; 7.4.1) VW 75209-2:2015-01 (p. 7.3; 7.4.1) VW 75209-2:2021-12 (p. 7.2; 7.3; 7.4.1) VW 75210-1:2023-06 (p. 7.2; 7.3; 7.4.1) VW 75210-1:2024-08 (p. 7.2; 7.3; 7.4.1) VW 75210-2:2023-06 (p. 7.2; 7.3; 7.4.1) MBN LV 112-1:2016-03 (p. 7.3; 7.4.1) MBN 50112-1:2023-06 (p. 10.3; 10.4.2) MBN 50112-2: 2023-05 (p. 10.3; 10.4.1) MBN 50216-1:2023-07 (p. 10.3; 10.5.2) MBN LV 212-1:2017-08 (p. 7.3; 7.4.1) MBN 50212-1:2023-04 (p. 10.2; 10.3.1; 10.3.2; 10.4.2) MBN LV 122:2017-06 (p. 9.4.1; 11.2.4) MBN 50122:2023-07 (p. 11.4.1; 13.2.5) MBN LV 216-2:2017-07 (p. 7.3; 7.5.1) MBN 50112-4:2024-06 (p. 10.3; 10.4.2) GS 95007-1-1:2013-05 (p. 7.3; 7.4.1) GS 95007-1-2:2013-05 (p. 7.3; 7.4.1) GS 95007-1-5:2015-07 (p. 9.4.1; 11.1.4) GS 95007-3-1:2015-08 (p. 7.3; 7.4.1) GS 95007-3-2:2015-09 (p. 7.3; 7.4.1) GS 95007-6-1:2016-03 (p. 7.3; 7.5.1) GS 95007-6-2:2017-04 (p. 7.3; 7.5.1) | ISO 14572:2011-10 (p. 4.7) Scope of accreditation No. AB 1776","categories":["construction"],"row_index":75,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Visual examinations: colour of insulation / sheath visual test of the cable lay direction of the conductor and stranded cables RAL colour charts Range 5015, 1001, 6016, 3015 LV 112-1:2013-04 (p. 7.3; 7.4.1) LV 112-2:2013-04 (p. 7.3; 7.4.1) LV 122:2015-05 (p. 9.4.1; 11.1.4) LV 122:2016-02 (p. 9.4.1; 11.2.4) LV 212-1:2015-01 (p. 7.3; 7.4.1) LV 212-2:2015-01 (p. 7.3; 7.4.1) LV 216-1:2015-07 (p. 7.3; 7.5.1) LV 216-2:2017-02 (p. 7.3; 7.5.1) VW 60306-1:2018-09-01 (p. 7.3; 7.4.1) VW 60306-1:2021-10 (p. 7.2; 7.3; 7.4.1) VW 60306-2:2013-04 (p. 7.3; 7.4.1) VW 60306-2:2021-11 (p. 7.3; 7.4.1) VW 60306-4:2021-12 (p. 7.2; 7.3; 7.4.1) VW 75205:2019-11 (p. 9.4.1; 11.1.4) VW 75205:2023-05 (p. 9.2; 9.4.1; 11.1.4) VW 75205:2024-04 (p. 11.2.5) VW 75209-1:2015-01 (p. 7.3; 7.4.1) VW 75209-1:2021-12 (p. 7.2; 7.3; 7.4.1) VW 75209-2:2015-01 (p. 7.3; 7.4.1) VW 75209-2:2021-12 (p. 7.2; 7.3; 7.4.1) VW 75210-1:2023-06 (p. 7.2; 7.3; 7.4.1) VW 75210-1:2024-08 (p. 7.2; 7.3; 7.4.1) VW 75210-2:2023-06 (p. 7.2; 7.3; 7.4.1) MBN LV 112-1:2016-03 (p. 7.3; 7.4.1) MBN 50112-1:2023-06 (p. 10.3; 10.4.2) MBN 50112-2: 2023-05 (p. 10.3; 10.4.1) MBN 50216-1:2023-07 (p. 10.3; 10.5.2) MBN LV 212-1:2017-08 (p. 7.3; 7.4.1) MBN 50212-1:2023-04 (p. 10.2; 10.3.1; 10.3.2; 10.4.2) MBN LV 122:2017-06 (p. 9.4.1; 11.2.4) MBN 50122:2023-07 (p. 11.4.1; 13.2.5) MBN LV 216-2:2017-07 (p. 7.3; 7.5.1) MBN 50112-4:2024-06 (p. 10.3; 10.4.2) GS 95007-1-1:2013-05 (p. 7.3; 7.4.1) GS 95007-1-2:2013-05 (p. 7.3; 7.4.1) GS 95007-1-5:2015-07 (p. 9.4.1; 11.1.4) GS 95007-3-1:2015-08 (p. 7.3; 7.4.1) GS 95007-3-2:2015-09 (p. 7.3; 7.4.1) GS 95007-6-1:2016-03 (p. 7.3; 7.5.1) GS 95007-6-2:2017-04 (p. 7.3; 7.5.1) | ISO 14572:2011-10 (p. 4.7) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"kolor izolacji / powłoki"},{"name":"test wizualny kabla"},{"name":"kierunek skrętu żyły i kabli skręconych"},{"name":"Tablice kolorów RAL","range":"9005, 5017, 8003,"},{"name":"范围","range":"7000, 6018, 2003, 3000, 4005, 1013, 1021,"},{"name":"5015, 1001, 6016, 3015"}],"search_zh":"电缆 范围 LV 112-1:2013-04 (p. 7.3; 7.4.1) LV 112-2:2013-04 (p. 7.3; 7.4.1) LV 122:2015-05 (p. 9.4.1; 11.1.4) LV 122:2016-02 (p. 9.4.1; 11.2.4) LV 212-1:2015-01 (p. 7.3; 7.4.1) LV 212-2:2015-01 (p. 7.3; 7.4.1) LV 216-1:2015-07 (p. 7.3; 7.5.1) LV 216-2:2017-02 (p. 7.3; 7.5.1) VW 60306-1:2018-09-01 (p. 7.3; 7.4.1) VW 60306-1:2021-10 (p. 7.2; 7.3; 7.4.1) VW 60306-2:2013-04 (p. 7.3; 7.4.1) VW 60306-2:2021-11 (p. 7.3; 7.4.1) VW 60306-4:2021-12 (p. 7.2; 7.3; 7.4.1) VW 75205:2019-11 (p. 9.4.1; 11.1.4) VW 75205:2023-05 (p. 9.2; 9.4.1; 11.1.4) VW 75205:2024-04 (p. 11.2.5) VW 75209-1:2015-01 (p. 7.3; 7.4.1) VW 75209-1:2021-12 (p. 7.2; 7.3; 7.4.1) VW 75209-2:2015-01 (p. 7.3; 7.4.1) VW 75209-2:2021-12 (p. 7.2; 7.3; 7.4.1) VW 75210-1:2023-06 (p. 7.2; 7.3; 7.4.1) VW 75210-1:2024-08 (p. 7.2; 7.3; 7.4.1) VW 75210-2:2023-06 (p. 7.2; 7.3; 7.4.1) MBN LV 112-1:2016-03 (p. 7.3; 7.4.1) MBN 50112-1:2023-06 (p. 10.3; 10.4.2) MBN 50112-2: 2023-05 (p. 10.3; 10.4.1) MBN 50216-1:2023-07 (p. 10.3; 10.5.2) MBN LV 212-1:2017-08 (p. 7.3; 7.4.1) MBN 50212-1:2023-04 (p. 10.2; 10.3.1; 10.3.2; 10.4.2) MBN LV 122:2017-06 (p. 9.4.1; 11.2.4) MBN 50122:2023-07 (p. 11.4.1; 13.2.5) MBN LV 216-2:2017-07 (p. 7.3; 7.5.1) MBN 50112-4:2024-06 (p. 10.3; 10.4.2) GS 95007-1-1:2013-05 (p. 7.3; 7.4.1) GS 95007-1-2:2013-05 (p. 7.3; 7.4.1) GS 95007-1-5:2015-07 (p. 9.4.1; 11.1.4) GS 95007-3-1:2015-08 (p. 7.3; 7.4.1) GS 95007-3-2:2015-09 (p. 7.3; 7.4.1) GS 95007-6-1:2016-03 (p. 7.3; 7.5.1) GS 95007-6-2:2017-04 (p. 7.3; 7.5.1) | ISO 14572:2011-10 (p. 4.7) Scope of accreditation No. AB 1776","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ee4","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Określenie wytrzymałości na rozciąganie i wydłużenie przy zrywaniu:","methodology_en":"Determination of tensile strength and elongation at break:","parameters":[{"name":"w temperaturze pokojowej"},{"name":"po krótkotrwałym starzeniu"},{"name":"po długotrwałym starzeniu Maszyna wytrzymałościowa:","range":"do 20 kN,"},{"name":"Ekstensometr","range":"do 600 mm"}],"parameters_en":[{"name":"at room temperature"},{"name":"after short-term ageing"},{"name":"after long-term ageing Testing machine:","range":"do 20 kN,"},{"name":"Extensometer","range":"do 600 mm"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Określenie wytrzymałości na rozciąganie i wydłużenie przy zrywaniu:\nZakres:\nw temperaturze pokojowej\npo krótkotrwałym starzeniu\npo długotrwałym starzeniu Maszyna wytrzymałościowa: do 20 kN,\nEkstensometr do 600 mm","reference":"LV 112-1:2013-04 (p. 9.2.7; 9.6.7.3; 9.6.8.3) LV 112-1:2014-04 (p. 9.2.7; 9.6.7.3; 9.6.8.3) LV 112-2:2013-04 (p. 9.2; 9.6.7.3; 9.6.8.3) LV 212-1:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) LV 212-2:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) LV 216-1:2015-07 (p. 9.2.7; 9.6.7.3; 9.6.8.3) LV 216-2: 2017-02 (p. 9.2.7; 9.6.6.3; 9.6.7.3) VW 60306-1:2018-09-01 (p. 9.2.3) VW 60306-1:2021-10 (p. 9.3.4) VW 60306-2:2013-04 (p. 9.2; 9.6.7.3; 9.6.8.3) VW 60306-2:2021-11 (p. 9.3.4) VW 60306-4:2021-12 (p. 9.3.4) VW 75209-1:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) VW 75209-1:2021-12 (p. 9.3.4) VW 75209-2:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) VW 75209-2:2021-12 (p. 9.3.3) VW 75210-1:2023-06 (p. 9.3.5) VW 75210-1:2024-08 (p. 9.3.5) VW 75210-2:2023-06 (p. 9.3.5) MBN LV 112-1:2016-03 (p. 9.2.7; 9.6.7.3; 9.6.8.3) MBN 50112-1:2023-06 (p. 12.2.8; 12.6.7.4; 12.6.8.4) MBN 50216-1:2023-07 (p. 12.3.7; 12.7.6.4; 12.7.7.4) MBN LV 212-1:2017-08 MBN 50212-1:2023-04 (p. 12.3.8; 12.7.6.4; 12.7.8.4) (p. 9.2.7; 9.6.6.3; 9.6.7.3) MBN LV 216-2:2017-07 (p. 9.2.7; 9.6.6.3; 9.6.7.3) MBN 50112-4:2024-06 (p. 12.2.8; 12.2.8.1; 12.2.8.2; 12.6.7.3; 12.6.8.3) GS 95007-1-1:2013-05 (p. 9.2.7; 9.6.7.3; 9.6.8.3) GS 95007-1-2:2013-05 (p. 9.2; 9.6.7.3; 9.6.8.3) GS 95007-3-1:2015-08 (p. 9.2.7; 9.6.6.3; 9.6.7.3) GS 95007-3-2:2015-09 (p. 9.2.7; 9.6.6.3; 9.6.7.3) GS 95007-6-1:2016-03 (p. 9.2.7; 9.6.7.3; 9.6.8.3) GS 95007-6-2:2017-04 (p. 9.2.7; 9.6.6.3; 9.6.7.3) Scope of accreditation No. AB 1776","norm_bases":["LV 112-1:2013-04 (p. 9.2.7; 9.6.7.3; 9.6.8.3) LV 112-1:2014-04 (p. 9.2.7; 9.6.7.3; 9.6.8.3) LV 112-2:2013-04 (p. 9.2; 9.6.7.3; 9.6.8.3) LV 212-1:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) LV 212-2:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) LV 216-1:2015-07 (p. 9.2.7; 9.6.7.3; 9.6.8.3) LV 216-2: 2017-02 (p. 9.2.7; 9.6.6.3; 9.6.7.3) VW 60306-1:2018-09-01 (p. 9.2.3) VW 60306-1:2021-10 (p. 9.3.4) VW 60306-2:2013-04 (p. 9.2; 9.6.7.3; 9.6.8.3) VW 60306-2:2021-11 (p. 9.3.4) VW 60306-4:2021-12 (p. 9.3.4) VW 75209-1:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) VW 75209-1:2021-12 (p. 9.3.4) VW 75209-2:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) VW 75209-2:2021-12 (p. 9.3.3) VW 75210-1:2023-06 (p. 9.3.5) VW 75210-1:2024-08 (p. 9.3.5) VW 75210-2:2023-06 (p. 9.3.5) MBN LV 112-1:2016-03 (p. 9.2.7; 9.6.7.3; 9.6.8.3) MBN 50112-1:2023-06 (p. 12.2.8; 12.6.7.4; 12.6.8.4) MBN 50216-1:2023-07 (p. 12.3.7; 12.7.6.4; 12.7.7.4) MBN LV 212-1:2017-08 MBN 50212-1:2023-04 (p. 12.3.8; 12.7.6.4; 12.7.8.4) (p. 9.2.7; 9.6.6.3; 9.6.7.3) MBN LV 216-2:2017-07 (p. 9.2.7; 9.6.6.3; 9.6.7.3) MBN 50112-4:2024-06 (p. 12.2.8; 12.2.8.1; 12.2.8.2; 12.6.7.3; 12.6.8.3) GS 95007-1-1:2013-05 (p. 9.2.7; 9.6.7.3; 9.6.8.3) GS 95007-1-2:2013-05 (p. 9.2; 9.6.7.3; 9.6.8.3) GS 95007-3-1:2015-08 (p. 9.2.7; 9.6.6.3; 9.6.7.3) GS 95007-3-2:2015-09 (p. 9.2.7; 9.6.6.3; 9.6.7.3) GS 95007-6-1:2016-03 (p. 9.2.7; 9.6.7.3; 9.6.8.3) GS 95007-6-2:2017-04 (p. 9.2.7; 9.6.6.3; 9.6.7.3) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Określenie wytrzymałości na rozciąganie i wydłużenie przy zrywaniu:\nZakres:\nw temperaturze pokojowej\npo krótkotrwałym starzeniu\npo długotrwałym starzeniu Maszyna wytrzymałościowa: do 20 kN,\nEkstensometr do 600 mm LV 112-1:2013-04 (p. 9.2.7; 9.6.7.3; 9.6.8.3) LV 112-1:2014-04 (p. 9.2.7; 9.6.7.3; 9.6.8.3) LV 112-2:2013-04 (p. 9.2; 9.6.7.3; 9.6.8.3) LV 212-1:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) LV 212-2:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) LV 216-1:2015-07 (p. 9.2.7; 9.6.7.3; 9.6.8.3) LV 216-2: 2017-02 (p. 9.2.7; 9.6.6.3; 9.6.7.3) VW 60306-1:2018-09-01 (p. 9.2.3) VW 60306-1:2021-10 (p. 9.3.4) VW 60306-2:2013-04 (p. 9.2; 9.6.7.3; 9.6.8.3) VW 60306-2:2021-11 (p. 9.3.4) VW 60306-4:2021-12 (p. 9.3.4) VW 75209-1:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) VW 75209-1:2021-12 (p. 9.3.4) VW 75209-2:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) VW 75209-2:2021-12 (p. 9.3.3) VW 75210-1:2023-06 (p. 9.3.5) VW 75210-1:2024-08 (p. 9.3.5) VW 75210-2:2023-06 (p. 9.3.5) MBN LV 112-1:2016-03 (p. 9.2.7; 9.6.7.3; 9.6.8.3) MBN 50112-1:2023-06 (p. 12.2.8; 12.6.7.4; 12.6.8.4) MBN 50216-1:2023-07 (p. 12.3.7; 12.7.6.4; 12.7.7.4) MBN LV 212-1:2017-08 MBN 50212-1:2023-04 (p. 12.3.8; 12.7.6.4; 12.7.8.4) (p. 9.2.7; 9.6.6.3; 9.6.7.3) MBN LV 216-2:2017-07 (p. 9.2.7; 9.6.6.3; 9.6.7.3) MBN 50112-4:2024-06 (p. 12.2.8; 12.2.8.1; 12.2.8.2; 12.6.7.3; 12.6.8.3) GS 95007-1-1:2013-05 (p. 9.2.7; 9.6.7.3; 9.6.8.3) GS 95007-1-2:2013-05 (p. 9.2; 9.6.7.3; 9.6.8.3) GS 95007-3-1:2015-08 (p. 9.2.7; 9.6.6.3; 9.6.7.3) GS 95007-3-2:2015-09 (p. 9.2.7; 9.6.6.3; 9.6.7.3) GS 95007-6-1:2016-03 (p. 9.2.7; 9.6.7.3; 9.6.8.3) GS 95007-6-2:2017-04 (p. 9.2.7; 9.6.6.3; 9.6.7.3) Scope of accreditation No. AB 1776 Kable, Cables Okreslenie wytrzymalosci na rozciaganie i wydluzenie przy zrywaniu:\nZakres:\nw temperaturze pokojowej\npo krotkotrwalym starzeniu\npo dlugotrwalym starzeniu Maszyna wytrzymalosciowa: do 20 kN,\nEkstensometr do 600 mm LV 112-1:2013-04 (p. 9.2.7; 9.6.7.3; 9.6.8.3) LV 112-1:2014-04 (p. 9.2.7; 9.6.7.3; 9.6.8.3) LV 112-2:2013-04 (p. 9.2; 9.6.7.3; 9.6.8.3) LV 212-1:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) LV 212-2:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) LV 216-1:2015-07 (p. 9.2.7; 9.6.7.3; 9.6.8.3) LV 216-2: 2017-02 (p. 9.2.7; 9.6.6.3; 9.6.7.3) VW 60306-1:2018-09-01 (p. 9.2.3) VW 60306-1:2021-10 (p. 9.3.4) VW 60306-2:2013-04 (p. 9.2; 9.6.7.3; 9.6.8.3) VW 60306-2:2021-11 (p. 9.3.4) VW 60306-4:2021-12 (p. 9.3.4) VW 75209-1:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) VW 75209-1:2021-12 (p. 9.3.4) VW 75209-2:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) VW 75209-2:2021-12 (p. 9.3.3) VW 75210-1:2023-06 (p. 9.3.5) VW 75210-1:2024-08 (p. 9.3.5) VW 75210-2:2023-06 (p. 9.3.5) MBN LV 112-1:2016-03 (p. 9.2.7; 9.6.7.3; 9.6.8.3) MBN 50112-1:2023-06 (p. 12.2.8; 12.6.7.4; 12.6.8.4) MBN 50216-1:2023-07 (p. 12.3.7; 12.7.6.4; 12.7.7.4) MBN LV 212-1:2017-08 MBN 50212-1:2023-04 (p. 12.3.8; 12.7.6.4; 12.7.8.4) (p. 9.2.7; 9.6.6.3; 9.6.7.3) MBN LV 216-2:2017-07 (p. 9.2.7; 9.6.6.3; 9.6.7.3) MBN 50112-4:2024-06 (p. 12.2.8; 12.2.8.1; 12.2.8.2; 12.6.7.3; 12.6.8.3) GS 95007-1-1:2013-05 (p. 9.2.7; 9.6.7.3; 9.6.8.3) GS 95007-1-2:2013-05 (p. 9.2; 9.6.7.3; 9.6.8.3) GS 95007-3-1:2015-08 (p. 9.2.7; 9.6.6.3; 9.6.7.3) GS 95007-3-2:2015-09 (p. 9.2.7; 9.6.6.3; 9.6.7.3) GS 95007-6-1:2016-03 (p. 9.2.7; 9.6.7.3; 9.6.8.3) GS 95007-6-2:2017-04 (p. 9.2.7; 9.6.6.3; 9.6.7.3) Scope of accreditation No. AB 1776","categories":["other"],"row_index":76,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Determination of tensile strength and elongation at break: at room temperature after short-term ageing after long-term ageing Testing machine: Extensometer LV 112-1:2013-04 (p. 9.2.7; 9.6.7.3; 9.6.8.3) LV 112-1:2014-04 (p. 9.2.7; 9.6.7.3; 9.6.8.3) LV 112-2:2013-04 (p. 9.2; 9.6.7.3; 9.6.8.3) LV 212-1:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) LV 212-2:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) LV 216-1:2015-07 (p. 9.2.7; 9.6.7.3; 9.6.8.3) LV 216-2: 2017-02 (p. 9.2.7; 9.6.6.3; 9.6.7.3) VW 60306-1:2018-09-01 (p. 9.2.3) VW 60306-1:2021-10 (p. 9.3.4) VW 60306-2:2013-04 (p. 9.2; 9.6.7.3; 9.6.8.3) VW 60306-2:2021-11 (p. 9.3.4) VW 60306-4:2021-12 (p. 9.3.4) VW 75209-1:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) VW 75209-1:2021-12 (p. 9.3.4) VW 75209-2:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) VW 75209-2:2021-12 (p. 9.3.3) VW 75210-1:2023-06 (p. 9.3.5) VW 75210-1:2024-08 (p. 9.3.5) VW 75210-2:2023-06 (p. 9.3.5) MBN LV 112-1:2016-03 (p. 9.2.7; 9.6.7.3; 9.6.8.3) MBN 50112-1:2023-06 (p. 12.2.8; 12.6.7.4; 12.6.8.4) MBN 50216-1:2023-07 (p. 12.3.7; 12.7.6.4; 12.7.7.4) MBN LV 212-1:2017-08 MBN 50212-1:2023-04 (p. 12.3.8; 12.7.6.4; 12.7.8.4) (p. 9.2.7; 9.6.6.3; 9.6.7.3) MBN LV 216-2:2017-07 (p. 9.2.7; 9.6.6.3; 9.6.7.3) MBN 50112-4:2024-06 (p. 12.2.8; 12.2.8.1; 12.2.8.2; 12.6.7.3; 12.6.8.3) GS 95007-1-1:2013-05 (p. 9.2.7; 9.6.7.3; 9.6.8.3) GS 95007-1-2:2013-05 (p. 9.2; 9.6.7.3; 9.6.8.3) GS 95007-3-1:2015-08 (p. 9.2.7; 9.6.6.3; 9.6.7.3) GS 95007-3-2:2015-09 (p. 9.2.7; 9.6.6.3; 9.6.7.3) GS 95007-6-1:2016-03 (p. 9.2.7; 9.6.7.3; 9.6.8.3) GS 95007-6-2:2017-04 (p. 9.2.7; 9.6.6.3; 9.6.7.3) Scope of accreditation No. AB 1776","search_zh":"电缆 室温下 引伸计 LV 112-1:2013-04 (p. 9.2.7; 9.6.7.3; 9.6.8.3) LV 112-1:2014-04 (p. 9.2.7; 9.6.7.3; 9.6.8.3) LV 112-2:2013-04 (p. 9.2; 9.6.7.3; 9.6.8.3) LV 212-1:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) LV 212-2:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) LV 216-1:2015-07 (p. 9.2.7; 9.6.7.3; 9.6.8.3) LV 216-2: 2017-02 (p. 9.2.7; 9.6.6.3; 9.6.7.3) VW 60306-1:2018-09-01 (p. 9.2.3) VW 60306-1:2021-10 (p. 9.3.4) VW 60306-2:2013-04 (p. 9.2; 9.6.7.3; 9.6.8.3) VW 60306-2:2021-11 (p. 9.3.4) VW 60306-4:2021-12 (p. 9.3.4) VW 75209-1:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) VW 75209-1:2021-12 (p. 9.3.4) VW 75209-2:2015-01 (p. 9.2.7; 9.6.6.3; 9.6.7.3) VW 75209-2:2021-12 (p. 9.3.3) VW 75210-1:2023-06 (p. 9.3.5) VW 75210-1:2024-08 (p. 9.3.5) VW 75210-2:2023-06 (p. 9.3.5) MBN LV 112-1:2016-03 (p. 9.2.7; 9.6.7.3; 9.6.8.3) MBN 50112-1:2023-06 (p. 12.2.8; 12.6.7.4; 12.6.8.4) MBN 50216-1:2023-07 (p. 12.3.7; 12.7.6.4; 12.7.7.4) MBN LV 212-1:2017-08 MBN 50212-1:2023-04 (p. 12.3.8; 12.7.6.4; 12.7.8.4) (p. 9.2.7; 9.6.6.3; 9.6.7.3) MBN LV 216-2:2017-07 (p. 9.2.7; 9.6.6.3; 9.6.7.3) MBN 50112-4:2024-06 (p. 12.2.8; 12.2.8.1; 12.2.8.2; 12.6.7.3; 12.6.8.3) GS 95007-1-1:2013-05 (p. 9.2.7; 9.6.7.3; 9.6.8.3) GS 95007-1-2:2013-05 (p. 9.2; 9.6.7.3; 9.6.8.3) GS 95007-3-1:2015-08 (p. 9.2.7; 9.6.6.3; 9.6.7.3) GS 95007-3-2:2015-09 (p. 9.2.7; 9.6.6.3; 9.6.7.3) GS 95007-6-1:2016-03 (p. 9.2.7; 9.6.7.3; 9.6.8.3) GS 95007-6-2:2017-04 (p. 9.2.7; 9.6.6.3; 9.6.7.3) Scope of accreditation No. AB 1776","test_object_zh":"电缆","parameters_zh":[{"name":"室温下"},{"name":"po krótkotrwałym starzeniu"},{"name":"po długotrwałym starzeniu Maszyna wytrzymałościowa:","range":"do 20 kN,"},{"name":"引伸计","range":"do 600 mm"}]},{"_id":"6a5dc9a9f1c10c8ce8259ee5","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Wskaźnik ściągalności izolacji (A-faktor), Insulation strippability factor (A-factor)","methodology_en":"Insulation strippability factor (A-factor)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik ściągalności izolacji (A-faktor), Insulation strippability factor (A-factor)","reference":"VW 60306-1:2018-09-01 (p. 9.1.4) VW 60306-1:2021-10 (p. 9.2.5) VW 60306-4:2021-12 (p. 9.2.5)","norm_bases":["VW 60306-1:2018-09-01 (p. 9.1.4) VW 60306-1:2021-10 (p. 9.2.5) VW 60306-4:2021-12 (p. 9.2.5)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Wskaźnik ściągalności izolacji (A-faktor), Insulation strippability factor (A-factor) VW 60306-1:2018-09-01 (p. 9.1.4) VW 60306-1:2021-10 (p. 9.2.5) VW 60306-4:2021-12 (p. 9.2.5) Kable, Cables Wskaznik sciagalnosci izolacji (A-faktor), Insulation strippability factor (A-factor) VW 60306-1:2018-09-01 (p. 9.1.4) VW 60306-1:2021-10 (p. 9.2.5) VW 60306-4:2021-12 (p. 9.2.5)","categories":["construction"],"row_index":77,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Insulation strippability factor (A-factor) VW 60306-1:2018-09-01 (p. 9.1.4) VW 60306-1:2021-10 (p. 9.2.5) VW 60306-4:2021-12 (p. 9.2.5)","search_zh":"电缆 VW 60306-1:2018-09-01 (p. 9.1.4) VW 60306-1:2021-10 (p. 9.2.5) VW 60306-4:2021-12 (p. 9.2.5)","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ee6","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Wyznaczenie stopnia usieciowania","methodology_en":"Determination of the degree of cross-linking","parameters":[{"name":"Piec","range":"do 200 °C (± 2 °C)"}],"parameters_en":[{"name":"Stove","range":"do 200 °C (± 2 °C)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wyznaczenie stopnia usieciowania\nPiec do 200 °C (± 2 °C)","reference":"DIN EN 60811-507:2012-12 | DIN EN 60811-2-1:2002-09 LV 112-1:2013-04 (p. 9.2.9) LV 112-1:2014-04 (p. 9.2.9) LV 112-2:2013-04 (p. 9.2) LV 212-1:2015-01 (p. 9.2.9) LV 212-2:2015-01 (p. 9.2.9) LV 216-1:2015-07 (p. 9.2.9) LV 216-2:2017-02 (p. 9.2.9) VW 60306-1:2018-09-01 (p. 9.2.5) VW 60306-1:2021-10 (p. 9.3.6) VW 60306-2:2013-04 (p. 9.2) VW 60306-2:2021-11 (p. 9.3.6) VW 60306-4:2021-12 (p. 9.3.6) VW 75209-1:2015-01 (p. 9.2.9) VW 75209-1:2021-12 (p. 9.3.6) VW 75209-2:2015-01 (p. 9.2.9) VW 75209-2:2021-12 (p. 9.3.5) VW 75210-1:2023-06 (p. 9.3.7) VW 75210-1:2024-08 (p. 9.3.7) VW 75210-2:2023-06 (p. 9.3.7) MBN LV 112-1:2016-03 (p. 9.2.9) MBN 50112-1:2023-06 (p. 12.2.10) MBN 50216-1:2023-07 (p. 12.3.10) MBN LV 212-1:2017-08 (p. 9.2.9) MBN 50212-1:2023-04 (p. 12.3.10) MBN LV 216-2:2017-07 (p. 9.2.9) MBN 50112-4:2024-06 (p. 12.2.10) GS 95007-1-1:2013-05 (p. 9.2.9) GS 95007-1-2:2013-05 (p. 9.2) GS 95007-3-1:2015-08 (p. 9.2.9) GS 95007-3-2:2015-09 (p. 9.2.9) GS 95007-6-1:2016-03 (p. 9.2.9) GS 95007-6-2:2017-04 (p. 9.2.9) Scope of accreditation No. AB 1776","norm_bases":["DIN EN 60811-507:2012-12","DIN EN 60811-2-1:2002-09 LV 112-1:2013-04 (p. 9.2.9) LV 112-1:2014-04 (p. 9.2.9) LV 112-2:2013-04 (p. 9.2) LV 212-1:2015-01 (p. 9.2.9) LV 212-2:2015-01 (p. 9.2.9) LV 216-1:2015-07 (p. 9.2.9) LV 216-2:2017-02 (p. 9.2.9) VW 60306-1:2018-09-01 (p. 9.2.5) VW 60306-1:2021-10 (p. 9.3.6) VW 60306-2:2013-04 (p. 9.2) VW 60306-2:2021-11 (p. 9.3.6) VW 60306-4:2021-12 (p. 9.3.6) VW 75209-1:2015-01 (p. 9.2.9) VW 75209-1:2021-12 (p. 9.3.6) VW 75209-2:2015-01 (p. 9.2.9) VW 75209-2:2021-12 (p. 9.3.5) VW 75210-1:2023-06 (p. 9.3.7) VW 75210-1:2024-08 (p. 9.3.7) VW 75210-2:2023-06 (p. 9.3.7) MBN LV 112-1:2016-03 (p. 9.2.9) MBN 50112-1:2023-06 (p. 12.2.10) MBN 50216-1:2023-07 (p. 12.3.10) MBN LV 212-1:2017-08 (p. 9.2.9) MBN 50212-1:2023-04 (p. 12.3.10) MBN LV 216-2:2017-07 (p. 9.2.9) MBN 50112-4:2024-06 (p. 12.2.10) GS 95007-1-1:2013-05 (p. 9.2.9) GS 95007-1-2:2013-05 (p. 9.2) GS 95007-3-1:2015-08 (p. 9.2.9) GS 95007-3-2:2015-09 (p. 9.2.9) GS 95007-6-1:2016-03 (p. 9.2.9) GS 95007-6-2:2017-04 (p. 9.2.9) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Wyznaczenie stopnia usieciowania\nPiec do 200 °C (± 2 °C) DIN EN 60811-507:2012-12 | DIN EN 60811-2-1:2002-09 LV 112-1:2013-04 (p. 9.2.9) LV 112-1:2014-04 (p. 9.2.9) LV 112-2:2013-04 (p. 9.2) LV 212-1:2015-01 (p. 9.2.9) LV 212-2:2015-01 (p. 9.2.9) LV 216-1:2015-07 (p. 9.2.9) LV 216-2:2017-02 (p. 9.2.9) VW 60306-1:2018-09-01 (p. 9.2.5) VW 60306-1:2021-10 (p. 9.3.6) VW 60306-2:2013-04 (p. 9.2) VW 60306-2:2021-11 (p. 9.3.6) VW 60306-4:2021-12 (p. 9.3.6) VW 75209-1:2015-01 (p. 9.2.9) VW 75209-1:2021-12 (p. 9.3.6) VW 75209-2:2015-01 (p. 9.2.9) VW 75209-2:2021-12 (p. 9.3.5) VW 75210-1:2023-06 (p. 9.3.7) VW 75210-1:2024-08 (p. 9.3.7) VW 75210-2:2023-06 (p. 9.3.7) MBN LV 112-1:2016-03 (p. 9.2.9) MBN 50112-1:2023-06 (p. 12.2.10) MBN 50216-1:2023-07 (p. 12.3.10) MBN LV 212-1:2017-08 (p. 9.2.9) MBN 50212-1:2023-04 (p. 12.3.10) MBN LV 216-2:2017-07 (p. 9.2.9) MBN 50112-4:2024-06 (p. 12.2.10) GS 95007-1-1:2013-05 (p. 9.2.9) GS 95007-1-2:2013-05 (p. 9.2) GS 95007-3-1:2015-08 (p. 9.2.9) GS 95007-3-2:2015-09 (p. 9.2.9) GS 95007-6-1:2016-03 (p. 9.2.9) GS 95007-6-2:2017-04 (p. 9.2.9) Scope of accreditation No. AB 1776 Kable, Cables Wyznaczenie stopnia usieciowania\nPiec do 200 °C (± 2 °C) DIN EN 60811-507:2012-12 | DIN EN 60811-2-1:2002-09 LV 112-1:2013-04 (p. 9.2.9) LV 112-1:2014-04 (p. 9.2.9) LV 112-2:2013-04 (p. 9.2) LV 212-1:2015-01 (p. 9.2.9) LV 212-2:2015-01 (p. 9.2.9) LV 216-1:2015-07 (p. 9.2.9) LV 216-2:2017-02 (p. 9.2.9) VW 60306-1:2018-09-01 (p. 9.2.5) VW 60306-1:2021-10 (p. 9.3.6) VW 60306-2:2013-04 (p. 9.2) VW 60306-2:2021-11 (p. 9.3.6) VW 60306-4:2021-12 (p. 9.3.6) VW 75209-1:2015-01 (p. 9.2.9) VW 75209-1:2021-12 (p. 9.3.6) VW 75209-2:2015-01 (p. 9.2.9) VW 75209-2:2021-12 (p. 9.3.5) VW 75210-1:2023-06 (p. 9.3.7) VW 75210-1:2024-08 (p. 9.3.7) VW 75210-2:2023-06 (p. 9.3.7) MBN LV 112-1:2016-03 (p. 9.2.9) MBN 50112-1:2023-06 (p. 12.2.10) MBN 50216-1:2023-07 (p. 12.3.10) MBN LV 212-1:2017-08 (p. 9.2.9) MBN 50212-1:2023-04 (p. 12.3.10) MBN LV 216-2:2017-07 (p. 9.2.9) MBN 50112-4:2024-06 (p. 12.2.10) GS 95007-1-1:2013-05 (p. 9.2.9) GS 95007-1-2:2013-05 (p. 9.2) GS 95007-3-1:2015-08 (p. 9.2.9) GS 95007-3-2:2015-09 (p. 9.2.9) GS 95007-6-1:2016-03 (p. 9.2.9) GS 95007-6-2:2017-04 (p. 9.2.9) Scope of accreditation No. AB 1776","categories":["other"],"row_index":78,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Determination of the degree of cross-linking Stove DIN EN 60811-507:2012-12 | DIN EN 60811-2-1:2002-09 LV 112-1:2013-04 (p. 9.2.9) LV 112-1:2014-04 (p. 9.2.9) LV 112-2:2013-04 (p. 9.2) LV 212-1:2015-01 (p. 9.2.9) LV 212-2:2015-01 (p. 9.2.9) LV 216-1:2015-07 (p. 9.2.9) LV 216-2:2017-02 (p. 9.2.9) VW 60306-1:2018-09-01 (p. 9.2.5) VW 60306-1:2021-10 (p. 9.3.6) VW 60306-2:2013-04 (p. 9.2) VW 60306-2:2021-11 (p. 9.3.6) VW 60306-4:2021-12 (p. 9.3.6) VW 75209-1:2015-01 (p. 9.2.9) VW 75209-1:2021-12 (p. 9.3.6) VW 75209-2:2015-01 (p. 9.2.9) VW 75209-2:2021-12 (p. 9.3.5) VW 75210-1:2023-06 (p. 9.3.7) VW 75210-1:2024-08 (p. 9.3.7) VW 75210-2:2023-06 (p. 9.3.7) MBN LV 112-1:2016-03 (p. 9.2.9) MBN 50112-1:2023-06 (p. 12.2.10) MBN 50216-1:2023-07 (p. 12.3.10) MBN LV 212-1:2017-08 (p. 9.2.9) MBN 50212-1:2023-04 (p. 12.3.10) MBN LV 216-2:2017-07 (p. 9.2.9) MBN 50112-4:2024-06 (p. 12.2.10) GS 95007-1-1:2013-05 (p. 9.2.9) GS 95007-1-2:2013-05 (p. 9.2) GS 95007-3-1:2015-08 (p. 9.2.9) GS 95007-3-2:2015-09 (p. 9.2.9) GS 95007-6-1:2016-03 (p. 9.2.9) GS 95007-6-2:2017-04 (p. 9.2.9) Scope of accreditation No. AB 1776","search_zh":"电缆 炉窑 DIN EN 60811-507:2012-12 | DIN EN 60811-2-1:2002-09 LV 112-1:2013-04 (p. 9.2.9) LV 112-1:2014-04 (p. 9.2.9) LV 112-2:2013-04 (p. 9.2) LV 212-1:2015-01 (p. 9.2.9) LV 212-2:2015-01 (p. 9.2.9) LV 216-1:2015-07 (p. 9.2.9) LV 216-2:2017-02 (p. 9.2.9) VW 60306-1:2018-09-01 (p. 9.2.5) VW 60306-1:2021-10 (p. 9.3.6) VW 60306-2:2013-04 (p. 9.2) VW 60306-2:2021-11 (p. 9.3.6) VW 60306-4:2021-12 (p. 9.3.6) VW 75209-1:2015-01 (p. 9.2.9) VW 75209-1:2021-12 (p. 9.3.6) VW 75209-2:2015-01 (p. 9.2.9) VW 75209-2:2021-12 (p. 9.3.5) VW 75210-1:2023-06 (p. 9.3.7) VW 75210-1:2024-08 (p. 9.3.7) VW 75210-2:2023-06 (p. 9.3.7) MBN LV 112-1:2016-03 (p. 9.2.9) MBN 50112-1:2023-06 (p. 12.2.10) MBN 50216-1:2023-07 (p. 12.3.10) MBN LV 212-1:2017-08 (p. 9.2.9) MBN 50212-1:2023-04 (p. 12.3.10) MBN LV 216-2:2017-07 (p. 9.2.9) MBN 50112-4:2024-06 (p. 12.2.10) GS 95007-1-1:2013-05 (p. 9.2.9) GS 95007-1-2:2013-05 (p. 9.2) GS 95007-3-1:2015-08 (p. 9.2.9) GS 95007-3-2:2015-09 (p. 9.2.9) GS 95007-6-1:2016-03 (p. 9.2.9) GS 95007-6-2:2017-04 (p. 9.2.9) Scope of accreditation No. AB 1776","test_object_zh":"电缆","parameters_zh":[{"name":"炉窑","range":"do 200 °C (± 2 °C)"}]},{"_id":"6a5dc9a9f1c10c8ce8259ee7","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Siła zginania kabla","methodology_en":"Cable bending force","parameters":[{"name":"Maszyna wytrzymałościowa","range":"do 20 kN"}],"parameters_en":[{"name":"Testing machine","range":"do 20 kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Siła zginania kabla\nMaszyna wytrzymałościowa do 20 kN","reference":"LV 112-1:2013-04 (p. 9.3.4) LV 112-1:2014-04 (p. 9.3.4) LV 112-2:2007-11 (p. 8.4.5) LV 112-2:2013-04 (p. 9.3.4) LV 212-1:2015-01 (p. 9.3.4) LV 212-2:2015-01 (p. 9.3.4) LV 216-1:2015-07 (p. 9.3.4) LV 216-2:2017-02 (p. 9.3.4) VW 60306-1:2018-09-01 (p. 9.3.3) VW 60306-1:2021-10 (p. 9.4.3) VW 60306-2:2013-04 (p. 9.3.4) VW 60306-2:2021-11 (p. 9.4.3) VW 60306-4:2021-12 (p. 9.4.3) VW 75209-1:2015-01 (p. 9.3.4) VW 75209-1:2021-12 (p. 9.4.3) VW 75209-2:2015-01 (p. 9.3.4) VW 75209-2:2021-12 (p. 9.4.2) VW 75210-1:2023-06 (p. 9.4.3) VW 75210-1:2024-08 (p. 9.4.3) VW 75210-2:2023-06 (p. 9.4.3) MBN LV 112-1:2016-03 (p. 9.3.4) MBN 50112-1:2023-06 (p. 12.3.5) MBN LV 112-2:2012-01 (p. 8.4.5) MBN 50112-2:2023-05 (p. 12.4.5) MBN 50216-1:2023-07 (p. 12.4.5) MBN LV 212-1:2017-08 (p. 9.3.4) MBN 50212-1:2023-04 (p. 12.4.4) MBN LV 216-2:2017-07 (p. 9.3.4) MBN 50112-4:2024-06 (p. 12.3.6) GS 95007-1-1:2013-05 (p. 9.3.4) GS 95007-1-2:2013-05 (p. 9.3.4) GS 95007-3-1:2015-08 (p. 9.3.4) GS 95007-3-2:2015-09 (p. 9.3.4) GS 95007-6-1:2016-03 (p. 9.3.4) GS 95007-6-2:2017-04 (p. 9.3.4) Scope of accreditation No. AB 1776","norm_bases":["LV 112-1:2013-04 (p. 9.3.4) LV 112-1:2014-04 (p. 9.3.4) LV 112-2:2007-11 (p. 8.4.5) LV 112-2:2013-04 (p. 9.3.4) LV 212-1:2015-01 (p. 9.3.4) LV 212-2:2015-01 (p. 9.3.4) LV 216-1:2015-07 (p. 9.3.4) LV 216-2:2017-02 (p. 9.3.4) VW 60306-1:2018-09-01 (p. 9.3.3) VW 60306-1:2021-10 (p. 9.4.3) VW 60306-2:2013-04 (p. 9.3.4) VW 60306-2:2021-11 (p. 9.4.3) VW 60306-4:2021-12 (p. 9.4.3) VW 75209-1:2015-01 (p. 9.3.4) VW 75209-1:2021-12 (p. 9.4.3) VW 75209-2:2015-01 (p. 9.3.4) VW 75209-2:2021-12 (p. 9.4.2) VW 75210-1:2023-06 (p. 9.4.3) VW 75210-1:2024-08 (p. 9.4.3) VW 75210-2:2023-06 (p. 9.4.3) MBN LV 112-1:2016-03 (p. 9.3.4) MBN 50112-1:2023-06 (p. 12.3.5) MBN LV 112-2:2012-01 (p. 8.4.5) MBN 50112-2:2023-05 (p. 12.4.5) MBN 50216-1:2023-07 (p. 12.4.5) MBN LV 212-1:2017-08 (p. 9.3.4) MBN 50212-1:2023-04 (p. 12.4.4) MBN LV 216-2:2017-07 (p. 9.3.4) MBN 50112-4:2024-06 (p. 12.3.6) GS 95007-1-1:2013-05 (p. 9.3.4) GS 95007-1-2:2013-05 (p. 9.3.4) GS 95007-3-1:2015-08 (p. 9.3.4) GS 95007-3-2:2015-09 (p. 9.3.4) GS 95007-6-1:2016-03 (p. 9.3.4) GS 95007-6-2:2017-04 (p. 9.3.4) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Siła zginania kabla\nMaszyna wytrzymałościowa do 20 kN LV 112-1:2013-04 (p. 9.3.4) LV 112-1:2014-04 (p. 9.3.4) LV 112-2:2007-11 (p. 8.4.5) LV 112-2:2013-04 (p. 9.3.4) LV 212-1:2015-01 (p. 9.3.4) LV 212-2:2015-01 (p. 9.3.4) LV 216-1:2015-07 (p. 9.3.4) LV 216-2:2017-02 (p. 9.3.4) VW 60306-1:2018-09-01 (p. 9.3.3) VW 60306-1:2021-10 (p. 9.4.3) VW 60306-2:2013-04 (p. 9.3.4) VW 60306-2:2021-11 (p. 9.4.3) VW 60306-4:2021-12 (p. 9.4.3) VW 75209-1:2015-01 (p. 9.3.4) VW 75209-1:2021-12 (p. 9.4.3) VW 75209-2:2015-01 (p. 9.3.4) VW 75209-2:2021-12 (p. 9.4.2) VW 75210-1:2023-06 (p. 9.4.3) VW 75210-1:2024-08 (p. 9.4.3) VW 75210-2:2023-06 (p. 9.4.3) MBN LV 112-1:2016-03 (p. 9.3.4) MBN 50112-1:2023-06 (p. 12.3.5) MBN LV 112-2:2012-01 (p. 8.4.5) MBN 50112-2:2023-05 (p. 12.4.5) MBN 50216-1:2023-07 (p. 12.4.5) MBN LV 212-1:2017-08 (p. 9.3.4) MBN 50212-1:2023-04 (p. 12.4.4) MBN LV 216-2:2017-07 (p. 9.3.4) MBN 50112-4:2024-06 (p. 12.3.6) GS 95007-1-1:2013-05 (p. 9.3.4) GS 95007-1-2:2013-05 (p. 9.3.4) GS 95007-3-1:2015-08 (p. 9.3.4) GS 95007-3-2:2015-09 (p. 9.3.4) GS 95007-6-1:2016-03 (p. 9.3.4) GS 95007-6-2:2017-04 (p. 9.3.4) Scope of accreditation No. AB 1776 Kable, Cables Sila zginania kabla\nMaszyna wytrzymalosciowa do 20 kN LV 112-1:2013-04 (p. 9.3.4) LV 112-1:2014-04 (p. 9.3.4) LV 112-2:2007-11 (p. 8.4.5) LV 112-2:2013-04 (p. 9.3.4) LV 212-1:2015-01 (p. 9.3.4) LV 212-2:2015-01 (p. 9.3.4) LV 216-1:2015-07 (p. 9.3.4) LV 216-2:2017-02 (p. 9.3.4) VW 60306-1:2018-09-01 (p. 9.3.3) VW 60306-1:2021-10 (p. 9.4.3) VW 60306-2:2013-04 (p. 9.3.4) VW 60306-2:2021-11 (p. 9.4.3) VW 60306-4:2021-12 (p. 9.4.3) VW 75209-1:2015-01 (p. 9.3.4) VW 75209-1:2021-12 (p. 9.4.3) VW 75209-2:2015-01 (p. 9.3.4) VW 75209-2:2021-12 (p. 9.4.2) VW 75210-1:2023-06 (p. 9.4.3) VW 75210-1:2024-08 (p. 9.4.3) VW 75210-2:2023-06 (p. 9.4.3) MBN LV 112-1:2016-03 (p. 9.3.4) MBN 50112-1:2023-06 (p. 12.3.5) MBN LV 112-2:2012-01 (p. 8.4.5) MBN 50112-2:2023-05 (p. 12.4.5) MBN 50216-1:2023-07 (p. 12.4.5) MBN LV 212-1:2017-08 (p. 9.3.4) MBN 50212-1:2023-04 (p. 12.4.4) MBN LV 216-2:2017-07 (p. 9.3.4) MBN 50112-4:2024-06 (p. 12.3.6) GS 95007-1-1:2013-05 (p. 9.3.4) GS 95007-1-2:2013-05 (p. 9.3.4) GS 95007-3-1:2015-08 (p. 9.3.4) GS 95007-3-2:2015-09 (p. 9.3.4) GS 95007-6-1:2016-03 (p. 9.3.4) GS 95007-6-2:2017-04 (p. 9.3.4) Scope of accreditation No. AB 1776","categories":["other"],"row_index":79,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Cable bending force Testing machine LV 112-1:2013-04 (p. 9.3.4) LV 112-1:2014-04 (p. 9.3.4) LV 112-2:2007-11 (p. 8.4.5) LV 112-2:2013-04 (p. 9.3.4) LV 212-1:2015-01 (p. 9.3.4) LV 212-2:2015-01 (p. 9.3.4) LV 216-1:2015-07 (p. 9.3.4) LV 216-2:2017-02 (p. 9.3.4) VW 60306-1:2018-09-01 (p. 9.3.3) VW 60306-1:2021-10 (p. 9.4.3) VW 60306-2:2013-04 (p. 9.3.4) VW 60306-2:2021-11 (p. 9.4.3) VW 60306-4:2021-12 (p. 9.4.3) VW 75209-1:2015-01 (p. 9.3.4) VW 75209-1:2021-12 (p. 9.4.3) VW 75209-2:2015-01 (p. 9.3.4) VW 75209-2:2021-12 (p. 9.4.2) VW 75210-1:2023-06 (p. 9.4.3) VW 75210-1:2024-08 (p. 9.4.3) VW 75210-2:2023-06 (p. 9.4.3) MBN LV 112-1:2016-03 (p. 9.3.4) MBN 50112-1:2023-06 (p. 12.3.5) MBN LV 112-2:2012-01 (p. 8.4.5) MBN 50112-2:2023-05 (p. 12.4.5) MBN 50216-1:2023-07 (p. 12.4.5) MBN LV 212-1:2017-08 (p. 9.3.4) MBN 50212-1:2023-04 (p. 12.4.4) MBN LV 216-2:2017-07 (p. 9.3.4) MBN 50112-4:2024-06 (p. 12.3.6) GS 95007-1-1:2013-05 (p. 9.3.4) GS 95007-1-2:2013-05 (p. 9.3.4) GS 95007-3-1:2015-08 (p. 9.3.4) GS 95007-3-2:2015-09 (p. 9.3.4) GS 95007-6-1:2016-03 (p. 9.3.4) GS 95007-6-2:2017-04 (p. 9.3.4) Scope of accreditation No. AB 1776","search_zh":"电缆 材料试验机 LV 112-1:2013-04 (p. 9.3.4) LV 112-1:2014-04 (p. 9.3.4) LV 112-2:2007-11 (p. 8.4.5) LV 112-2:2013-04 (p. 9.3.4) LV 212-1:2015-01 (p. 9.3.4) LV 212-2:2015-01 (p. 9.3.4) LV 216-1:2015-07 (p. 9.3.4) LV 216-2:2017-02 (p. 9.3.4) VW 60306-1:2018-09-01 (p. 9.3.3) VW 60306-1:2021-10 (p. 9.4.3) VW 60306-2:2013-04 (p. 9.3.4) VW 60306-2:2021-11 (p. 9.4.3) VW 60306-4:2021-12 (p. 9.4.3) VW 75209-1:2015-01 (p. 9.3.4) VW 75209-1:2021-12 (p. 9.4.3) VW 75209-2:2015-01 (p. 9.3.4) VW 75209-2:2021-12 (p. 9.4.2) VW 75210-1:2023-06 (p. 9.4.3) VW 75210-1:2024-08 (p. 9.4.3) VW 75210-2:2023-06 (p. 9.4.3) MBN LV 112-1:2016-03 (p. 9.3.4) MBN 50112-1:2023-06 (p. 12.3.5) MBN LV 112-2:2012-01 (p. 8.4.5) MBN 50112-2:2023-05 (p. 12.4.5) MBN 50216-1:2023-07 (p. 12.4.5) MBN LV 212-1:2017-08 (p. 9.3.4) MBN 50212-1:2023-04 (p. 12.4.4) MBN LV 216-2:2017-07 (p. 9.3.4) MBN 50112-4:2024-06 (p. 12.3.6) GS 95007-1-1:2013-05 (p. 9.3.4) GS 95007-1-2:2013-05 (p. 9.3.4) GS 95007-3-1:2015-08 (p. 9.3.4) GS 95007-3-2:2015-09 (p. 9.3.4) GS 95007-6-1:2016-03 (p. 9.3.4) GS 95007-6-2:2017-04 (p. 9.3.4) Scope of accreditation No. AB 1776","test_object_zh":"电缆","parameters_zh":[{"name":"材料试验机","range":"do 20 kN"}]},{"_id":"6a5dc9a9f1c10c8ce8259ee8","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Wytrzymałość izolacji / powłoki na nacięcie","methodology_en":"Resistance of the insulation / sheath to notching","parameters":[{"name":"Maszyna wytrzymałościowa","range":"do 20 kN"}],"parameters_en":[{"name":"Testing machine","range":"do 20 kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość izolacji / powłoki na nacięcie\nMaszyna wytrzymałościowa do 20 kN","reference":"LV 112-1:2013-04 (p. 9.3.5) LV 112-1:2014-04 (p. 9.3.5) LV 112-2:2007-11 (p. 8.4.6) LV 112-2:2013-04 (p. 9.3.5) LV 212-2:2015-01 (p. 9.3.5) LV 216-1:2015-07 (p. 9.3.5) LV 216-2:2017-02 (p. 9.3.5) VW 60306-1:2018-09-01 (p. 9.3.4) VW 60306-1:2021-10 (p. 9.4.4) VW 60306-2:2013-04 (p. 9.3.5) VW 60306-2:2021-11 (p. 9.4.4) VW 60306-4:2021-12 (p. 9.4.4) VW 75209-1:2015-01 (p. 9.3.5) VW 75209-2:2015-01 (p. 9.3.5) VW 75209-2:2021-12 (p. 9.4.3) VW 75210-1:2023-06 (p. 9.4.4) VW 75210-1:2024-08 (p. 9.4.4) VW 75210-2:2023-06 (p. 9.4.4) MBN LV 112-1:2016-03 (p. 9.3.5) MBN 50112-1:2023-06 (p. 12.3.6) MBN LV 112-2:2012-01 (p. 8.4.6) MBN 50112-2:2023-05 (p. 12.4.6) MBN 50216-1:2023-07 (p. 12.4.6) MBN LV 216-2:2017-07 (p. 9.3.5) MBN 50112-4:2024-06 (p. 12.3.7) GS 95007-1-1:2013-05 (p. 9.3.5) GS 95007-1-2:2013-05 (p. 9.3.5) GS 95007-3-2:2015-09 (p. 9.3.5) GS 95007-6-1:2016-03 (p. 9.3.5) GS 95007-6-2:2017-04 (p. 9.3.5)","norm_bases":["LV 112-1:2013-04 (p. 9.3.5) LV 112-1:2014-04 (p. 9.3.5) LV 112-2:2007-11 (p. 8.4.6) LV 112-2:2013-04 (p. 9.3.5) LV 212-2:2015-01 (p. 9.3.5) LV 216-1:2015-07 (p. 9.3.5) LV 216-2:2017-02 (p. 9.3.5) VW 60306-1:2018-09-01 (p. 9.3.4) VW 60306-1:2021-10 (p. 9.4.4) VW 60306-2:2013-04 (p. 9.3.5) VW 60306-2:2021-11 (p. 9.4.4) VW 60306-4:2021-12 (p. 9.4.4) VW 75209-1:2015-01 (p. 9.3.5) VW 75209-2:2015-01 (p. 9.3.5) VW 75209-2:2021-12 (p. 9.4.3) VW 75210-1:2023-06 (p. 9.4.4) VW 75210-1:2024-08 (p. 9.4.4) VW 75210-2:2023-06 (p. 9.4.4) MBN LV 112-1:2016-03 (p. 9.3.5) MBN 50112-1:2023-06 (p. 12.3.6) MBN LV 112-2:2012-01 (p. 8.4.6) MBN 50112-2:2023-05 (p. 12.4.6) MBN 50216-1:2023-07 (p. 12.4.6) MBN LV 216-2:2017-07 (p. 9.3.5) MBN 50112-4:2024-06 (p. 12.3.7) GS 95007-1-1:2013-05 (p. 9.3.5) GS 95007-1-2:2013-05 (p. 9.3.5) GS 95007-3-2:2015-09 (p. 9.3.5) GS 95007-6-1:2016-03 (p. 9.3.5) GS 95007-6-2:2017-04 (p. 9.3.5)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Wytrzymałość izolacji / powłoki na nacięcie\nMaszyna wytrzymałościowa do 20 kN LV 112-1:2013-04 (p. 9.3.5) LV 112-1:2014-04 (p. 9.3.5) LV 112-2:2007-11 (p. 8.4.6) LV 112-2:2013-04 (p. 9.3.5) LV 212-2:2015-01 (p. 9.3.5) LV 216-1:2015-07 (p. 9.3.5) LV 216-2:2017-02 (p. 9.3.5) VW 60306-1:2018-09-01 (p. 9.3.4) VW 60306-1:2021-10 (p. 9.4.4) VW 60306-2:2013-04 (p. 9.3.5) VW 60306-2:2021-11 (p. 9.4.4) VW 60306-4:2021-12 (p. 9.4.4) VW 75209-1:2015-01 (p. 9.3.5) VW 75209-2:2015-01 (p. 9.3.5) VW 75209-2:2021-12 (p. 9.4.3) VW 75210-1:2023-06 (p. 9.4.4) VW 75210-1:2024-08 (p. 9.4.4) VW 75210-2:2023-06 (p. 9.4.4) MBN LV 112-1:2016-03 (p. 9.3.5) MBN 50112-1:2023-06 (p. 12.3.6) MBN LV 112-2:2012-01 (p. 8.4.6) MBN 50112-2:2023-05 (p. 12.4.6) MBN 50216-1:2023-07 (p. 12.4.6) MBN LV 216-2:2017-07 (p. 9.3.5) MBN 50112-4:2024-06 (p. 12.3.7) GS 95007-1-1:2013-05 (p. 9.3.5) GS 95007-1-2:2013-05 (p. 9.3.5) GS 95007-3-2:2015-09 (p. 9.3.5) GS 95007-6-1:2016-03 (p. 9.3.5) GS 95007-6-2:2017-04 (p. 9.3.5) Kable, Cables Wytrzymalosc izolacji / powloki na naciecie\nMaszyna wytrzymalosciowa do 20 kN LV 112-1:2013-04 (p. 9.3.5) LV 112-1:2014-04 (p. 9.3.5) LV 112-2:2007-11 (p. 8.4.6) LV 112-2:2013-04 (p. 9.3.5) LV 212-2:2015-01 (p. 9.3.5) LV 216-1:2015-07 (p. 9.3.5) LV 216-2:2017-02 (p. 9.3.5) VW 60306-1:2018-09-01 (p. 9.3.4) VW 60306-1:2021-10 (p. 9.4.4) VW 60306-2:2013-04 (p. 9.3.5) VW 60306-2:2021-11 (p. 9.4.4) VW 60306-4:2021-12 (p. 9.4.4) VW 75209-1:2015-01 (p. 9.3.5) VW 75209-2:2015-01 (p. 9.3.5) VW 75209-2:2021-12 (p. 9.4.3) VW 75210-1:2023-06 (p. 9.4.4) VW 75210-1:2024-08 (p. 9.4.4) VW 75210-2:2023-06 (p. 9.4.4) MBN LV 112-1:2016-03 (p. 9.3.5) MBN 50112-1:2023-06 (p. 12.3.6) MBN LV 112-2:2012-01 (p. 8.4.6) MBN 50112-2:2023-05 (p. 12.4.6) MBN 50216-1:2023-07 (p. 12.4.6) MBN LV 216-2:2017-07 (p. 9.3.5) MBN 50112-4:2024-06 (p. 12.3.7) GS 95007-1-1:2013-05 (p. 9.3.5) GS 95007-1-2:2013-05 (p. 9.3.5) GS 95007-3-2:2015-09 (p. 9.3.5) GS 95007-6-1:2016-03 (p. 9.3.5) GS 95007-6-2:2017-04 (p. 9.3.5)","categories":["construction"],"row_index":80,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Resistance of the insulation / sheath to notching Testing machine LV 112-1:2013-04 (p. 9.3.5) LV 112-1:2014-04 (p. 9.3.5) LV 112-2:2007-11 (p. 8.4.6) LV 112-2:2013-04 (p. 9.3.5) LV 212-2:2015-01 (p. 9.3.5) LV 216-1:2015-07 (p. 9.3.5) LV 216-2:2017-02 (p. 9.3.5) VW 60306-1:2018-09-01 (p. 9.3.4) VW 60306-1:2021-10 (p. 9.4.4) VW 60306-2:2013-04 (p. 9.3.5) VW 60306-2:2021-11 (p. 9.4.4) VW 60306-4:2021-12 (p. 9.4.4) VW 75209-1:2015-01 (p. 9.3.5) VW 75209-2:2015-01 (p. 9.3.5) VW 75209-2:2021-12 (p. 9.4.3) VW 75210-1:2023-06 (p. 9.4.4) VW 75210-1:2024-08 (p. 9.4.4) VW 75210-2:2023-06 (p. 9.4.4) MBN LV 112-1:2016-03 (p. 9.3.5) MBN 50112-1:2023-06 (p. 12.3.6) MBN LV 112-2:2012-01 (p. 8.4.6) MBN 50112-2:2023-05 (p. 12.4.6) MBN 50216-1:2023-07 (p. 12.4.6) MBN LV 216-2:2017-07 (p. 9.3.5) MBN 50112-4:2024-06 (p. 12.3.7) GS 95007-1-1:2013-05 (p. 9.3.5) GS 95007-1-2:2013-05 (p. 9.3.5) GS 95007-3-2:2015-09 (p. 9.3.5) GS 95007-6-1:2016-03 (p. 9.3.5) GS 95007-6-2:2017-04 (p. 9.3.5)","search_zh":"电缆 材料试验机 LV 112-1:2013-04 (p. 9.3.5) LV 112-1:2014-04 (p. 9.3.5) LV 112-2:2007-11 (p. 8.4.6) LV 112-2:2013-04 (p. 9.3.5) LV 212-2:2015-01 (p. 9.3.5) LV 216-1:2015-07 (p. 9.3.5) LV 216-2:2017-02 (p. 9.3.5) VW 60306-1:2018-09-01 (p. 9.3.4) VW 60306-1:2021-10 (p. 9.4.4) VW 60306-2:2013-04 (p. 9.3.5) VW 60306-2:2021-11 (p. 9.4.4) VW 60306-4:2021-12 (p. 9.4.4) VW 75209-1:2015-01 (p. 9.3.5) VW 75209-2:2015-01 (p. 9.3.5) VW 75209-2:2021-12 (p. 9.4.3) VW 75210-1:2023-06 (p. 9.4.4) VW 75210-1:2024-08 (p. 9.4.4) VW 75210-2:2023-06 (p. 9.4.4) MBN LV 112-1:2016-03 (p. 9.3.5) MBN 50112-1:2023-06 (p. 12.3.6) MBN LV 112-2:2012-01 (p. 8.4.6) MBN 50112-2:2023-05 (p. 12.4.6) MBN 50216-1:2023-07 (p. 12.4.6) MBN LV 216-2:2017-07 (p. 9.3.5) MBN 50112-4:2024-06 (p. 12.3.7) GS 95007-1-1:2013-05 (p. 9.3.5) GS 95007-1-2:2013-05 (p. 9.3.5) GS 95007-3-2:2015-09 (p. 9.3.5) GS 95007-6-1:2016-03 (p. 9.3.5) GS 95007-6-2:2017-04 (p. 9.3.5)","test_object_zh":"电缆","parameters_zh":[{"name":"材料试验机","range":"do 20 kN"}]},{"_id":"6a5dc9a9f1c10c8ce8259ee9","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Stabilność termiczna w stanie nawinięcia","methodology_en":"Thermal stability in the wound state","parameters":[{"name":"Piec","range":"do 200 °C (± 2 °C)"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV do 6 kV D.C. Thermal stability in wound state Range:"}],"parameters_en":[{"name":"Stove","range":"do 200 °C (± 2 °C)"},{"name":"Range","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV to 6 kV D.C. Thermal stability in wound state Range:"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stabilność termiczna w stanie nawinięcia\nZakres:\nPiec do 200 °C (± 2 °C)\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. Thermal stability in wound state Range:","reference":"LV 112-1:2013-04 (p. 9.6.5) LV 112-1:2014-04 (p. 9.6.5) LV 112-2:2007-11 (p. 8.7.4) LV 112-2:2013-04 (p. 9.6.5) LV 216-1:2015-07 (p. 9.6.5) VW 60306-1:2018-09-01 (p. 9.6.5) VW 60306-1:2021-10 (p. 9.7.5) VW 60306-2:2013-04 (p. 9.6.5) VW 60306-2:2021-11 (p. 9.7.5) VW 60306-4:2021-12 (p. 9.7.5) VW 75210-1:2023-06 (p. 9.7.5) VW 75210-1:2024-08 (p. 9.7.5) MBN LV 112-1:2016-03 (p. 9.6.5) MBN 50112-1:2023-06 (p. 12.6.5) MBN LV 112-2:2012-01 (p. 8.7.4) MBN 50112-2:2023-05 (p. 12.7.4) MBN 50216-1:2023-07 (p. 12.7.4.1) MBN 50112-4:2024-06 (p. 12.6.5) GS 95007-1-1:2013-05 (p. 9.6.5) GS 95007-1-2:2013-05 (p. 9.6.5) GS 95007-6-1:2016-03 (p. 9.6.5) Scope of accreditation No. AB 1776","norm_bases":["LV 112-1:2013-04 (p. 9.6.5) LV 112-1:2014-04 (p. 9.6.5) LV 112-2:2007-11 (p. 8.7.4) LV 112-2:2013-04 (p. 9.6.5) LV 216-1:2015-07 (p. 9.6.5) VW 60306-1:2018-09-01 (p. 9.6.5) VW 60306-1:2021-10 (p. 9.7.5) VW 60306-2:2013-04 (p. 9.6.5) VW 60306-2:2021-11 (p. 9.7.5) VW 60306-4:2021-12 (p. 9.7.5) VW 75210-1:2023-06 (p. 9.7.5) VW 75210-1:2024-08 (p. 9.7.5) MBN LV 112-1:2016-03 (p. 9.6.5) MBN 50112-1:2023-06 (p. 12.6.5) MBN LV 112-2:2012-01 (p. 8.7.4) MBN 50112-2:2023-05 (p. 12.7.4) MBN 50216-1:2023-07 (p. 12.7.4.1) MBN 50112-4:2024-06 (p. 12.6.5) GS 95007-1-1:2013-05 (p. 9.6.5) GS 95007-1-2:2013-05 (p. 9.6.5) GS 95007-6-1:2016-03 (p. 9.6.5) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Stabilność termiczna w stanie nawinięcia\nZakres:\nPiec do 200 °C (± 2 °C)\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. Thermal stability in wound state Range: LV 112-1:2013-04 (p. 9.6.5) LV 112-1:2014-04 (p. 9.6.5) LV 112-2:2007-11 (p. 8.7.4) LV 112-2:2013-04 (p. 9.6.5) LV 216-1:2015-07 (p. 9.6.5) VW 60306-1:2018-09-01 (p. 9.6.5) VW 60306-1:2021-10 (p. 9.7.5) VW 60306-2:2013-04 (p. 9.6.5) VW 60306-2:2021-11 (p. 9.7.5) VW 60306-4:2021-12 (p. 9.7.5) VW 75210-1:2023-06 (p. 9.7.5) VW 75210-1:2024-08 (p. 9.7.5) MBN LV 112-1:2016-03 (p. 9.6.5) MBN 50112-1:2023-06 (p. 12.6.5) MBN LV 112-2:2012-01 (p. 8.7.4) MBN 50112-2:2023-05 (p. 12.7.4) MBN 50216-1:2023-07 (p. 12.7.4.1) MBN 50112-4:2024-06 (p. 12.6.5) GS 95007-1-1:2013-05 (p. 9.6.5) GS 95007-1-2:2013-05 (p. 9.6.5) GS 95007-6-1:2016-03 (p. 9.6.5) Scope of accreditation No. AB 1776 Kable, Cables Stabilnosc termiczna w stanie nawiniecia\nZakres:\nPiec do 200 °C (± 2 °C)\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. Thermal stability in wound state Range: LV 112-1:2013-04 (p. 9.6.5) LV 112-1:2014-04 (p. 9.6.5) LV 112-2:2007-11 (p. 8.7.4) LV 112-2:2013-04 (p. 9.6.5) LV 216-1:2015-07 (p. 9.6.5) VW 60306-1:2018-09-01 (p. 9.6.5) VW 60306-1:2021-10 (p. 9.7.5) VW 60306-2:2013-04 (p. 9.6.5) VW 60306-2:2021-11 (p. 9.7.5) VW 60306-4:2021-12 (p. 9.7.5) VW 75210-1:2023-06 (p. 9.7.5) VW 75210-1:2024-08 (p. 9.7.5) MBN LV 112-1:2016-03 (p. 9.6.5) MBN 50112-1:2023-06 (p. 12.6.5) MBN LV 112-2:2012-01 (p. 8.7.4) MBN 50112-2:2023-05 (p. 12.7.4) MBN 50216-1:2023-07 (p. 12.7.4.1) MBN 50112-4:2024-06 (p. 12.6.5) GS 95007-1-1:2013-05 (p. 9.6.5) GS 95007-1-2:2013-05 (p. 9.6.5) GS 95007-6-1:2016-03 (p. 9.6.5) Scope of accreditation No. AB 1776","categories":["other"],"row_index":81,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Thermal stability in the wound state Stove Range 0,5 kV to 6 kV D.C. Thermal stability in wound state Range: LV 112-1:2013-04 (p. 9.6.5) LV 112-1:2014-04 (p. 9.6.5) LV 112-2:2007-11 (p. 8.7.4) LV 112-2:2013-04 (p. 9.6.5) LV 216-1:2015-07 (p. 9.6.5) VW 60306-1:2018-09-01 (p. 9.6.5) VW 60306-1:2021-10 (p. 9.7.5) VW 60306-2:2013-04 (p. 9.6.5) VW 60306-2:2021-11 (p. 9.7.5) VW 60306-4:2021-12 (p. 9.7.5) VW 75210-1:2023-06 (p. 9.7.5) VW 75210-1:2024-08 (p. 9.7.5) MBN LV 112-1:2016-03 (p. 9.6.5) MBN 50112-1:2023-06 (p. 12.6.5) MBN LV 112-2:2012-01 (p. 8.7.4) MBN 50112-2:2023-05 (p. 12.7.4) MBN 50216-1:2023-07 (p. 12.7.4.1) MBN 50112-4:2024-06 (p. 12.6.5) GS 95007-1-1:2013-05 (p. 9.6.5) GS 95007-1-2:2013-05 (p. 9.6.5) GS 95007-6-1:2016-03 (p. 9.6.5) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"炉窑","range":"do 200 °C (± 2 °C)"},{"name":"范围","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV do 6 kV D.C. Thermal stability in wound state Range:"}],"search_zh":"电缆 炉窑 范围 LV 112-1:2013-04 (p. 9.6.5) LV 112-1:2014-04 (p. 9.6.5) LV 112-2:2007-11 (p. 8.7.4) LV 112-2:2013-04 (p. 9.6.5) LV 216-1:2015-07 (p. 9.6.5) VW 60306-1:2018-09-01 (p. 9.6.5) VW 60306-1:2021-10 (p. 9.7.5) VW 60306-2:2013-04 (p. 9.6.5) VW 60306-2:2021-11 (p. 9.7.5) VW 60306-4:2021-12 (p. 9.7.5) VW 75210-1:2023-06 (p. 9.7.5) VW 75210-1:2024-08 (p. 9.7.5) MBN LV 112-1:2016-03 (p. 9.6.5) MBN 50112-1:2023-06 (p. 12.6.5) MBN LV 112-2:2012-01 (p. 8.7.4) MBN 50112-2:2023-05 (p. 12.7.4) MBN 50216-1:2023-07 (p. 12.7.4.1) MBN 50112-4:2024-06 (p. 12.6.5) GS 95007-1-1:2013-05 (p. 9.6.5) GS 95007-1-2:2013-05 (p. 9.6.5) GS 95007-6-1:2016-03 (p. 9.6.5) Scope of accreditation No. AB 1776","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259eea","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Odporność kabla na ekstremalne przeciążenie cieplne","methodology_en":"Resistance of the cable to extreme thermal overload","parameters":[{"name":"Piec","range":"do 200 °C (± 2 °C)"},{"name":"Komora klimatyczna","range":"-40 °C do 125 °C"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV do 6 kV D.C. Extreme thermal overload Range:"}],"parameters_en":[{"name":"Stove","range":"do 200 °C (± 2 °C)"},{"name":"Climatic chamber","range":"-40 °C do 125 °C"},{"name":"Range","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV to 6 kV D.C. Extreme thermal overload Range:"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność kabla na ekstremalne przeciążenie cieplne\nZakres:\nPiec do 200 °C (± 2 °C)\nKomora klimatyczna -40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. Extreme thermal overload Range:","reference":"LV 112-1:2013-04 (p. 9.6.6.2) LV 112-1:2014-04 (p. 9.6.6.2) LV 112-2:2013-04 (p. 9.6.6.2) LV 216-1:2015-07 (p. 9.6.6.2) VW 60306-1:2018-09-01 (p. 9.6.6.2) VW 60306-1:2021-10 (p. 9.7.6.2) VW 60306-2:2013-04 (p. 9.6.6.2) VW 60306-2:2021-11 (p. 9.7.6.2) VW 60306-4:2021-12 (p. 9.7.6.2) VW 75210-1:2024-08 (p. 9.7.6, 9.7.6.2) MBN LV 112-1:2016-03 (p. 9.6.6.2) MBN 50112-1:2023-06 (p. 12.6.6.2) MBN 50216-1:2023-07 (p. 12.7.5.3) MBN 50112-4:2024-06 (p. 12.6.6) GS 95007-1-1:2013-05 (p. 9.6.6.2) GS 95007-1-2:2013-05 (p. 9.6.6.2) GS 95007-6-1:2016-03 (p. 9.6.6.2)","norm_bases":["LV 112-1:2013-04 (p. 9.6.6.2) LV 112-1:2014-04 (p. 9.6.6.2) LV 112-2:2013-04 (p. 9.6.6.2) LV 216-1:2015-07 (p. 9.6.6.2) VW 60306-1:2018-09-01 (p. 9.6.6.2) VW 60306-1:2021-10 (p. 9.7.6.2) VW 60306-2:2013-04 (p. 9.6.6.2) VW 60306-2:2021-11 (p. 9.7.6.2) VW 60306-4:2021-12 (p. 9.7.6.2) VW 75210-1:2024-08 (p. 9.7.6, 9.7.6.2) MBN LV 112-1:2016-03 (p. 9.6.6.2) MBN 50112-1:2023-06 (p. 12.6.6.2) MBN 50216-1:2023-07 (p. 12.7.5.3) MBN 50112-4:2024-06 (p. 12.6.6) GS 95007-1-1:2013-05 (p. 9.6.6.2) GS 95007-1-2:2013-05 (p. 9.6.6.2) GS 95007-6-1:2016-03 (p. 9.6.6.2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Odporność kabla na ekstremalne przeciążenie cieplne\nZakres:\nPiec do 200 °C (± 2 °C)\nKomora klimatyczna -40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. Extreme thermal overload Range: LV 112-1:2013-04 (p. 9.6.6.2) LV 112-1:2014-04 (p. 9.6.6.2) LV 112-2:2013-04 (p. 9.6.6.2) LV 216-1:2015-07 (p. 9.6.6.2) VW 60306-1:2018-09-01 (p. 9.6.6.2) VW 60306-1:2021-10 (p. 9.7.6.2) VW 60306-2:2013-04 (p. 9.6.6.2) VW 60306-2:2021-11 (p. 9.7.6.2) VW 60306-4:2021-12 (p. 9.7.6.2) VW 75210-1:2024-08 (p. 9.7.6, 9.7.6.2) MBN LV 112-1:2016-03 (p. 9.6.6.2) MBN 50112-1:2023-06 (p. 12.6.6.2) MBN 50216-1:2023-07 (p. 12.7.5.3) MBN 50112-4:2024-06 (p. 12.6.6) GS 95007-1-1:2013-05 (p. 9.6.6.2) GS 95007-1-2:2013-05 (p. 9.6.6.2) GS 95007-6-1:2016-03 (p. 9.6.6.2) Kable, Cables Odpornosc kabla na ekstremalne przeciazenie cieplne\nZakres:\nPiec do 200 °C (± 2 °C)\nKomora klimatyczna -40 °C do 125 °C\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. Extreme thermal overload Range: LV 112-1:2013-04 (p. 9.6.6.2) LV 112-1:2014-04 (p. 9.6.6.2) LV 112-2:2013-04 (p. 9.6.6.2) LV 216-1:2015-07 (p. 9.6.6.2) VW 60306-1:2018-09-01 (p. 9.6.6.2) VW 60306-1:2021-10 (p. 9.7.6.2) VW 60306-2:2013-04 (p. 9.6.6.2) VW 60306-2:2021-11 (p. 9.7.6.2) VW 60306-4:2021-12 (p. 9.7.6.2) VW 75210-1:2024-08 (p. 9.7.6, 9.7.6.2) MBN LV 112-1:2016-03 (p. 9.6.6.2) MBN 50112-1:2023-06 (p. 12.6.6.2) MBN 50216-1:2023-07 (p. 12.7.5.3) MBN 50112-4:2024-06 (p. 12.6.6) GS 95007-1-1:2013-05 (p. 9.6.6.2) GS 95007-1-2:2013-05 (p. 9.6.6.2) GS 95007-6-1:2016-03 (p. 9.6.6.2)","categories":["other"],"row_index":82,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Resistance of the cable to extreme thermal overload Stove Climatic chamber Range 0,5 kV to 6 kV D.C. Extreme thermal overload Range: LV 112-1:2013-04 (p. 9.6.6.2) LV 112-1:2014-04 (p. 9.6.6.2) LV 112-2:2013-04 (p. 9.6.6.2) LV 216-1:2015-07 (p. 9.6.6.2) VW 60306-1:2018-09-01 (p. 9.6.6.2) VW 60306-1:2021-10 (p. 9.7.6.2) VW 60306-2:2013-04 (p. 9.6.6.2) VW 60306-2:2021-11 (p. 9.7.6.2) VW 60306-4:2021-12 (p. 9.7.6.2) VW 75210-1:2024-08 (p. 9.7.6, 9.7.6.2) MBN LV 112-1:2016-03 (p. 9.6.6.2) MBN 50112-1:2023-06 (p. 12.6.6.2) MBN 50216-1:2023-07 (p. 12.7.5.3) MBN 50112-4:2024-06 (p. 12.6.6) GS 95007-1-1:2013-05 (p. 9.6.6.2) GS 95007-1-2:2013-05 (p. 9.6.6.2) GS 95007-6-1:2016-03 (p. 9.6.6.2)","parameters_zh":[{"name":"炉窑","range":"do 200 °C (± 2 °C)"},{"name":"气候试验箱","range":"-40 °C do 125 °C"},{"name":"范围","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV do 6 kV D.C. Extreme thermal overload Range:"}],"search_zh":"电缆 炉窑 气候试验箱 范围 LV 112-1:2013-04 (p. 9.6.6.2) LV 112-1:2014-04 (p. 9.6.6.2) LV 112-2:2013-04 (p. 9.6.6.2) LV 216-1:2015-07 (p. 9.6.6.2) VW 60306-1:2018-09-01 (p. 9.6.6.2) VW 60306-1:2021-10 (p. 9.7.6.2) VW 60306-2:2013-04 (p. 9.6.6.2) VW 60306-2:2021-11 (p. 9.7.6.2) VW 60306-4:2021-12 (p. 9.7.6.2) VW 75210-1:2024-08 (p. 9.7.6, 9.7.6.2) MBN LV 112-1:2016-03 (p. 9.6.6.2) MBN 50112-1:2023-06 (p. 12.6.6.2) MBN 50216-1:2023-07 (p. 12.7.5.3) MBN 50112-4:2024-06 (p. 12.6.6) GS 95007-1-1:2013-05 (p. 9.6.6.2) GS 95007-1-2:2013-05 (p. 9.6.6.2) GS 95007-6-1:2016-03 (p. 9.6.6.2)","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259eeb","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Minimalny dopuszczalny promień gięcia dla statycznego prowadzenia kabla","methodology_en":"Minimum permissible bending radius for static cable routing","parameters":[{"name":"Piec","range":"do 200 °C (± 2 °C)"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV do 6 kV D.C."}],"parameters_en":[{"name":"Stove","range":"do 200 °C (± 2 °C)"},{"name":"Range","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Minimalny dopuszczalny promień gięcia dla statycznego prowadzenia kabla\nZakres:\nPiec do 200 °C (± 2 °C)\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C.","reference":"LV 112-1:2013-04 (p. 9.6.8.4) LV 112-2:2013-04 (p. 9.6.8.4) LV 212-1:2015-01 (p. 9.6.7.4) LV 212-2:2015-01 (p. 9.6.7.4) LV 216-1:2015-07 (p. 9.6.8.4) VW 60306-1:2018-09-01 (p. 9.6.8.2) VW 60306-1:2021-10 (p. 9.7.8.3) VW 60306-2:2013-04 (p. 9.6.8.4) VW 60306-2:2021-11 (p. 9.7.8.3) VW 60306-4:2021-12 (p. 9.7.8.3) VW 75209-1:2015-01 (p. 9.6.7.4) VW 75209-1:2021-12 (p. 9.7.6.3) VW 75209-2:2015-01 (p. 9.6.7.4) VW 75209-2:2021-12 (p. 9.7.6.3) VW 75210-1:2023-06 (p. 9.7.8.2) VW 75210-1:2024-08 (p. 9.7.7, 9.7.7.2; 9.7.8; 9.7.8.2) MBN LV 112-1:2016-03 (p. 9.6.8.4) MBN 50112-1:2023-06 (p. 12.6.8.5) MBN 50212-1:2023-04 (p. 12.7.7.5) MBN 50216-1:2023-07 (p. 12.7.7.5) MBN 50112-4:2024-06 (p. 12.6.8.4) MBN LV 212-1:2017-08 (p. 9.6.7.4) GS 95007-1-1:2013-05 (p. 9.6.8.4) GS 95007-1-2:2013-05 (p. 9.6.8.4) GS 95007-3-1:2015-08 (p. 9.6.7.4) GS 95007-3-2:2015-09 (p. 9.6.7.4) GS 95007-6-1:2016-03 (p. 9.6.8.4) Scope of accreditation No. AB 1776","norm_bases":["LV 112-1:2013-04 (p. 9.6.8.4) LV 112-2:2013-04 (p. 9.6.8.4) LV 212-1:2015-01 (p. 9.6.7.4) LV 212-2:2015-01 (p. 9.6.7.4) LV 216-1:2015-07 (p. 9.6.8.4) VW 60306-1:2018-09-01 (p. 9.6.8.2) VW 60306-1:2021-10 (p. 9.7.8.3) VW 60306-2:2013-04 (p. 9.6.8.4) VW 60306-2:2021-11 (p. 9.7.8.3) VW 60306-4:2021-12 (p. 9.7.8.3) VW 75209-1:2015-01 (p. 9.6.7.4) VW 75209-1:2021-12 (p. 9.7.6.3) VW 75209-2:2015-01 (p. 9.6.7.4) VW 75209-2:2021-12 (p. 9.7.6.3) VW 75210-1:2023-06 (p. 9.7.8.2) VW 75210-1:2024-08 (p. 9.7.7, 9.7.7.2; 9.7.8; 9.7.8.2) MBN LV 112-1:2016-03 (p. 9.6.8.4) MBN 50112-1:2023-06 (p. 12.6.8.5) MBN 50212-1:2023-04 (p. 12.7.7.5) MBN 50216-1:2023-07 (p. 12.7.7.5) MBN 50112-4:2024-06 (p. 12.6.8.4) MBN LV 212-1:2017-08 (p. 9.6.7.4) GS 95007-1-1:2013-05 (p. 9.6.8.4) GS 95007-1-2:2013-05 (p. 9.6.8.4) GS 95007-3-1:2015-08 (p. 9.6.7.4) GS 95007-3-2:2015-09 (p. 9.6.7.4) GS 95007-6-1:2016-03 (p. 9.6.8.4) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Minimalny dopuszczalny promień gięcia dla statycznego prowadzenia kabla\nZakres:\nPiec do 200 °C (± 2 °C)\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. LV 112-1:2013-04 (p. 9.6.8.4) LV 112-2:2013-04 (p. 9.6.8.4) LV 212-1:2015-01 (p. 9.6.7.4) LV 212-2:2015-01 (p. 9.6.7.4) LV 216-1:2015-07 (p. 9.6.8.4) VW 60306-1:2018-09-01 (p. 9.6.8.2) VW 60306-1:2021-10 (p. 9.7.8.3) VW 60306-2:2013-04 (p. 9.6.8.4) VW 60306-2:2021-11 (p. 9.7.8.3) VW 60306-4:2021-12 (p. 9.7.8.3) VW 75209-1:2015-01 (p. 9.6.7.4) VW 75209-1:2021-12 (p. 9.7.6.3) VW 75209-2:2015-01 (p. 9.6.7.4) VW 75209-2:2021-12 (p. 9.7.6.3) VW 75210-1:2023-06 (p. 9.7.8.2) VW 75210-1:2024-08 (p. 9.7.7, 9.7.7.2; 9.7.8; 9.7.8.2) MBN LV 112-1:2016-03 (p. 9.6.8.4) MBN 50112-1:2023-06 (p. 12.6.8.5) MBN 50212-1:2023-04 (p. 12.7.7.5) MBN 50216-1:2023-07 (p. 12.7.7.5) MBN 50112-4:2024-06 (p. 12.6.8.4) MBN LV 212-1:2017-08 (p. 9.6.7.4) GS 95007-1-1:2013-05 (p. 9.6.8.4) GS 95007-1-2:2013-05 (p. 9.6.8.4) GS 95007-3-1:2015-08 (p. 9.6.7.4) GS 95007-3-2:2015-09 (p. 9.6.7.4) GS 95007-6-1:2016-03 (p. 9.6.8.4) Scope of accreditation No. AB 1776 Kable, Cables Minimalny dopuszczalny promien giecia dla statycznego prowadzenia kabla\nZakres:\nPiec do 200 °C (± 2 °C)\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. LV 112-1:2013-04 (p. 9.6.8.4) LV 112-2:2013-04 (p. 9.6.8.4) LV 212-1:2015-01 (p. 9.6.7.4) LV 212-2:2015-01 (p. 9.6.7.4) LV 216-1:2015-07 (p. 9.6.8.4) VW 60306-1:2018-09-01 (p. 9.6.8.2) VW 60306-1:2021-10 (p. 9.7.8.3) VW 60306-2:2013-04 (p. 9.6.8.4) VW 60306-2:2021-11 (p. 9.7.8.3) VW 60306-4:2021-12 (p. 9.7.8.3) VW 75209-1:2015-01 (p. 9.6.7.4) VW 75209-1:2021-12 (p. 9.7.6.3) VW 75209-2:2015-01 (p. 9.6.7.4) VW 75209-2:2021-12 (p. 9.7.6.3) VW 75210-1:2023-06 (p. 9.7.8.2) VW 75210-1:2024-08 (p. 9.7.7, 9.7.7.2; 9.7.8; 9.7.8.2) MBN LV 112-1:2016-03 (p. 9.6.8.4) MBN 50112-1:2023-06 (p. 12.6.8.5) MBN 50212-1:2023-04 (p. 12.7.7.5) MBN 50216-1:2023-07 (p. 12.7.7.5) MBN 50112-4:2024-06 (p. 12.6.8.4) MBN LV 212-1:2017-08 (p. 9.6.7.4) GS 95007-1-1:2013-05 (p. 9.6.8.4) GS 95007-1-2:2013-05 (p. 9.6.8.4) GS 95007-3-1:2015-08 (p. 9.6.7.4) GS 95007-3-2:2015-09 (p. 9.6.7.4) GS 95007-6-1:2016-03 (p. 9.6.8.4) Scope of accreditation No. AB 1776","categories":["other"],"row_index":83,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Minimum permissible bending radius for static cable routing Stove Range 0,5 kV to 6 kV D.C. LV 112-1:2013-04 (p. 9.6.8.4) LV 112-2:2013-04 (p. 9.6.8.4) LV 212-1:2015-01 (p. 9.6.7.4) LV 212-2:2015-01 (p. 9.6.7.4) LV 216-1:2015-07 (p. 9.6.8.4) VW 60306-1:2018-09-01 (p. 9.6.8.2) VW 60306-1:2021-10 (p. 9.7.8.3) VW 60306-2:2013-04 (p. 9.6.8.4) VW 60306-2:2021-11 (p. 9.7.8.3) VW 60306-4:2021-12 (p. 9.7.8.3) VW 75209-1:2015-01 (p. 9.6.7.4) VW 75209-1:2021-12 (p. 9.7.6.3) VW 75209-2:2015-01 (p. 9.6.7.4) VW 75209-2:2021-12 (p. 9.7.6.3) VW 75210-1:2023-06 (p. 9.7.8.2) VW 75210-1:2024-08 (p. 9.7.7, 9.7.7.2; 9.7.8; 9.7.8.2) MBN LV 112-1:2016-03 (p. 9.6.8.4) MBN 50112-1:2023-06 (p. 12.6.8.5) MBN 50212-1:2023-04 (p. 12.7.7.5) MBN 50216-1:2023-07 (p. 12.7.7.5) MBN 50112-4:2024-06 (p. 12.6.8.4) MBN LV 212-1:2017-08 (p. 9.6.7.4) GS 95007-1-1:2013-05 (p. 9.6.8.4) GS 95007-1-2:2013-05 (p. 9.6.8.4) GS 95007-3-1:2015-08 (p. 9.6.7.4) GS 95007-3-2:2015-09 (p. 9.6.7.4) GS 95007-6-1:2016-03 (p. 9.6.8.4) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"炉窑","range":"do 200 °C (± 2 °C)"},{"name":"范围","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV do 6 kV D.C."}],"search_zh":"电缆 炉窑 范围 LV 112-1:2013-04 (p. 9.6.8.4) LV 112-2:2013-04 (p. 9.6.8.4) LV 212-1:2015-01 (p. 9.6.7.4) LV 212-2:2015-01 (p. 9.6.7.4) LV 216-1:2015-07 (p. 9.6.8.4) VW 60306-1:2018-09-01 (p. 9.6.8.2) VW 60306-1:2021-10 (p. 9.7.8.3) VW 60306-2:2013-04 (p. 9.6.8.4) VW 60306-2:2021-11 (p. 9.7.8.3) VW 60306-4:2021-12 (p. 9.7.8.3) VW 75209-1:2015-01 (p. 9.6.7.4) VW 75209-1:2021-12 (p. 9.7.6.3) VW 75209-2:2015-01 (p. 9.6.7.4) VW 75209-2:2021-12 (p. 9.7.6.3) VW 75210-1:2023-06 (p. 9.7.8.2) VW 75210-1:2024-08 (p. 9.7.7, 9.7.7.2; 9.7.8; 9.7.8.2) MBN LV 112-1:2016-03 (p. 9.6.8.4) MBN 50112-1:2023-06 (p. 12.6.8.5) MBN 50212-1:2023-04 (p. 12.7.7.5) MBN 50216-1:2023-07 (p. 12.7.7.5) MBN 50112-4:2024-06 (p. 12.6.8.4) MBN LV 212-1:2017-08 (p. 9.6.7.4) GS 95007-1-1:2013-05 (p. 9.6.8.4) GS 95007-1-2:2013-05 (p. 9.6.8.4) GS 95007-3-1:2015-08 (p. 9.6.7.4) GS 95007-3-2:2015-09 (p. 9.6.7.4) GS 95007-6-1:2016-03 (p. 9.6.8.4) Scope of accreditation No. AB 1776","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259eec","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Odporność kabla na łamanie","methodology_en":"Resistance of the cable to breaking","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność kabla na łamanie","reference":"LV 112-1:2013-04 (p. 9.6.13) LV 112-1:2014-04 (p. 9.6.13) LV 112-2:2007-11 (p. 8.7.12) LV 112-2:2013-04 (p. 9.6.13) LV 216-1:2015-07 (p. 9.6.13) VW 60306-1:2018-09-01 (p. 9.6.13) VW 60306-1:2021-10 (p. 9.7.13) VW 60306-2:2013-04 (p. 9.6.13) VW 60306-2:2021-11 (p. 9.7.13) VW 60306-4:2021-12 (p. 9.7.13) VW 75210-1:2024-08 (p. 9.7.13) MBN LV 112-1:2016-03 (p. 9.6.13) MBN 50112-1:2023-06 (p. 12.6.13) MBN LV 112-2:2012-01 (p. 8.7.12) MBN 50112-2:2023-05 (p. 12.7.12) MBN 50216-1:2023-07 (p. 12.7.12) MBN 50112-4:2024-06 (p. 12.6.13) GS 95007-1-1:2013-05 (p. 9.6.13) GS 95007-1-2:2013-05 (p. 9.6.13) GS 95007-6-1:2016-03 (p. 9.6.13)","norm_bases":["LV 112-1:2013-04 (p. 9.6.13) LV 112-1:2014-04 (p. 9.6.13) LV 112-2:2007-11 (p. 8.7.12) LV 112-2:2013-04 (p. 9.6.13) LV 216-1:2015-07 (p. 9.6.13) VW 60306-1:2018-09-01 (p. 9.6.13) VW 60306-1:2021-10 (p. 9.7.13) VW 60306-2:2013-04 (p. 9.6.13) VW 60306-2:2021-11 (p. 9.7.13) VW 60306-4:2021-12 (p. 9.7.13) VW 75210-1:2024-08 (p. 9.7.13) MBN LV 112-1:2016-03 (p. 9.6.13) MBN 50112-1:2023-06 (p. 12.6.13) MBN LV 112-2:2012-01 (p. 8.7.12) MBN 50112-2:2023-05 (p. 12.7.12) MBN 50216-1:2023-07 (p. 12.7.12) MBN 50112-4:2024-06 (p. 12.6.13) GS 95007-1-1:2013-05 (p. 9.6.13) GS 95007-1-2:2013-05 (p. 9.6.13) GS 95007-6-1:2016-03 (p. 9.6.13)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Odporność kabla na łamanie LV 112-1:2013-04 (p. 9.6.13) LV 112-1:2014-04 (p. 9.6.13) LV 112-2:2007-11 (p. 8.7.12) LV 112-2:2013-04 (p. 9.6.13) LV 216-1:2015-07 (p. 9.6.13) VW 60306-1:2018-09-01 (p. 9.6.13) VW 60306-1:2021-10 (p. 9.7.13) VW 60306-2:2013-04 (p. 9.6.13) VW 60306-2:2021-11 (p. 9.7.13) VW 60306-4:2021-12 (p. 9.7.13) VW 75210-1:2024-08 (p. 9.7.13) MBN LV 112-1:2016-03 (p. 9.6.13) MBN 50112-1:2023-06 (p. 12.6.13) MBN LV 112-2:2012-01 (p. 8.7.12) MBN 50112-2:2023-05 (p. 12.7.12) MBN 50216-1:2023-07 (p. 12.7.12) MBN 50112-4:2024-06 (p. 12.6.13) GS 95007-1-1:2013-05 (p. 9.6.13) GS 95007-1-2:2013-05 (p. 9.6.13) GS 95007-6-1:2016-03 (p. 9.6.13) Kable, Cables Odpornosc kabla na lamanie LV 112-1:2013-04 (p. 9.6.13) LV 112-1:2014-04 (p. 9.6.13) LV 112-2:2007-11 (p. 8.7.12) LV 112-2:2013-04 (p. 9.6.13) LV 216-1:2015-07 (p. 9.6.13) VW 60306-1:2018-09-01 (p. 9.6.13) VW 60306-1:2021-10 (p. 9.7.13) VW 60306-2:2013-04 (p. 9.6.13) VW 60306-2:2021-11 (p. 9.7.13) VW 60306-4:2021-12 (p. 9.7.13) VW 75210-1:2024-08 (p. 9.7.13) MBN LV 112-1:2016-03 (p. 9.6.13) MBN 50112-1:2023-06 (p. 12.6.13) MBN LV 112-2:2012-01 (p. 8.7.12) MBN 50112-2:2023-05 (p. 12.7.12) MBN 50216-1:2023-07 (p. 12.7.12) MBN 50112-4:2024-06 (p. 12.6.13) GS 95007-1-1:2013-05 (p. 9.6.13) GS 95007-1-2:2013-05 (p. 9.6.13) GS 95007-6-1:2016-03 (p. 9.6.13)","categories":["other"],"row_index":84,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Resistance of the cable to breaking LV 112-1:2013-04 (p. 9.6.13) LV 112-1:2014-04 (p. 9.6.13) LV 112-2:2007-11 (p. 8.7.12) LV 112-2:2013-04 (p. 9.6.13) LV 216-1:2015-07 (p. 9.6.13) VW 60306-1:2018-09-01 (p. 9.6.13) VW 60306-1:2021-10 (p. 9.7.13) VW 60306-2:2013-04 (p. 9.6.13) VW 60306-2:2021-11 (p. 9.7.13) VW 60306-4:2021-12 (p. 9.7.13) VW 75210-1:2024-08 (p. 9.7.13) MBN LV 112-1:2016-03 (p. 9.6.13) MBN 50112-1:2023-06 (p. 12.6.13) MBN LV 112-2:2012-01 (p. 8.7.12) MBN 50112-2:2023-05 (p. 12.7.12) MBN 50216-1:2023-07 (p. 12.7.12) MBN 50112-4:2024-06 (p. 12.6.13) GS 95007-1-1:2013-05 (p. 9.6.13) GS 95007-1-2:2013-05 (p. 9.6.13) GS 95007-6-1:2016-03 (p. 9.6.13)","search_zh":"电缆 LV 112-1:2013-04 (p. 9.6.13) LV 112-1:2014-04 (p. 9.6.13) LV 112-2:2007-11 (p. 8.7.12) LV 112-2:2013-04 (p. 9.6.13) LV 216-1:2015-07 (p. 9.6.13) VW 60306-1:2018-09-01 (p. 9.6.13) VW 60306-1:2021-10 (p. 9.7.13) VW 60306-2:2013-04 (p. 9.6.13) VW 60306-2:2021-11 (p. 9.7.13) VW 60306-4:2021-12 (p. 9.7.13) VW 75210-1:2024-08 (p. 9.7.13) MBN LV 112-1:2016-03 (p. 9.6.13) MBN 50112-1:2023-06 (p. 12.6.13) MBN LV 112-2:2012-01 (p. 8.7.12) MBN 50112-2:2023-05 (p. 12.7.12) MBN 50216-1:2023-07 (p. 12.7.12) MBN 50112-4:2024-06 (p. 12.6.13) GS 95007-1-1:2013-05 (p. 9.6.13) GS 95007-1-2:2013-05 (p. 9.6.13) GS 95007-6-1:2016-03 (p. 9.6.13)","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259eed","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Stałe, wilgotne ciepło (hydroliza)","methodology_en":"Damp heat, steady state (hydrolysis)","parameters":[{"name":"Komora klimatyczna","range":"-40 °C do 175 °C,"},{"name":"(85 ±5) % RH"},{"name":"Zakres","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV do 6 kV D.C."}],"parameters_en":[{"name":"Climatic chamber","range":"-40 °C do 175 °C,"},{"name":"(85 ±5) % RH"},{"name":"Range","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV to 6 kV D.C."}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stałe, wilgotne ciepło (hydroliza)\nZakres:\nKomora klimatyczna -40 °C do 175 °C,\n(85 ±5) % RH\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C.","reference":"LV 112-1:2013-04 (p. 9.6.15) LV 112-1:2014-04 (p. 9.6.15) LV 112-2:2007-11 (p. 8.7.14) LV 112-2:2013-04 (p. 9.6.15) LV 212-1:2015-01 (p. 9.6.13) LV 212-2:2015-01 (p. 9.6.13) LV 216-1:2015-07 (p. 9.6.15) VW 60306-1:2018-09-01 (p. 9.6.15) VW 60306-1:2021-10 (p. 9.7.15) VW 60306-2:2013-04 (p. 9.6.15) VW 60306-2:2021-11 (p. 9.7.15) VW 60306-4:2021-12 (p. 9.7.15) VW 75209-1:2015-01 (p. 9.6.13) VW 75209-1:2021-12 (p. 9.7.11) VW 75209-2:2015-01 (p. 9.6.13) VW 75209-2:2021-12 (p. 9.7.12) VW 75210-1:2023-06 (p. 9.7.15) VW 75210-1:2024-08 (p. 9.7.15) VW 75210-2:2023-06 (p. 9.7.12) MBN LV 112-1:2016-03 (p. 9.6.15) MBN 50112-1:2023-06 (p. 12.6.15) MBN LV 112-2:2012-01 (p. 8.7.14) MBN 50112-2:2023-05 (p. 12.7.14) MBN 50216-1:2023-07 (p. 12.7.14) MBN LV 212-1:2017-08 (p. 9.6.13) MBN 50112-4:2024-06 (p. 12.6.15) MBN 50212-1:2023-04 (p. 12.7.13) GS 95007-1-1:2013-05 (p. 9.6.15) GS 95007-1-2:2013-05 (p. 9.6.15) GS 95007-3-1:2015-08 (p. 9.6.13) GS 95007-3-2:2015-09 (p. 9.6.13) GS 95007-6-1:2016-03 (p. 9.6.15) Scope of accreditation No. AB 1776","norm_bases":["LV 112-1:2013-04 (p. 9.6.15) LV 112-1:2014-04 (p. 9.6.15) LV 112-2:2007-11 (p. 8.7.14) LV 112-2:2013-04 (p. 9.6.15) LV 212-1:2015-01 (p. 9.6.13) LV 212-2:2015-01 (p. 9.6.13) LV 216-1:2015-07 (p. 9.6.15) VW 60306-1:2018-09-01 (p. 9.6.15) VW 60306-1:2021-10 (p. 9.7.15) VW 60306-2:2013-04 (p. 9.6.15) VW 60306-2:2021-11 (p. 9.7.15) VW 60306-4:2021-12 (p. 9.7.15) VW 75209-1:2015-01 (p. 9.6.13) VW 75209-1:2021-12 (p. 9.7.11) VW 75209-2:2015-01 (p. 9.6.13) VW 75209-2:2021-12 (p. 9.7.12) VW 75210-1:2023-06 (p. 9.7.15) VW 75210-1:2024-08 (p. 9.7.15) VW 75210-2:2023-06 (p. 9.7.12) MBN LV 112-1:2016-03 (p. 9.6.15) MBN 50112-1:2023-06 (p. 12.6.15) MBN LV 112-2:2012-01 (p. 8.7.14) MBN 50112-2:2023-05 (p. 12.7.14) MBN 50216-1:2023-07 (p. 12.7.14) MBN LV 212-1:2017-08 (p. 9.6.13) MBN 50112-4:2024-06 (p. 12.6.15) MBN 50212-1:2023-04 (p. 12.7.13) GS 95007-1-1:2013-05 (p. 9.6.15) GS 95007-1-2:2013-05 (p. 9.6.15) GS 95007-3-1:2015-08 (p. 9.6.13) GS 95007-3-2:2015-09 (p. 9.6.13) GS 95007-6-1:2016-03 (p. 9.6.15) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Stałe, wilgotne ciepło (hydroliza)\nZakres:\nKomora klimatyczna -40 °C do 175 °C,\n(85 ±5) % RH\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. LV 112-1:2013-04 (p. 9.6.15) LV 112-1:2014-04 (p. 9.6.15) LV 112-2:2007-11 (p. 8.7.14) LV 112-2:2013-04 (p. 9.6.15) LV 212-1:2015-01 (p. 9.6.13) LV 212-2:2015-01 (p. 9.6.13) LV 216-1:2015-07 (p. 9.6.15) VW 60306-1:2018-09-01 (p. 9.6.15) VW 60306-1:2021-10 (p. 9.7.15) VW 60306-2:2013-04 (p. 9.6.15) VW 60306-2:2021-11 (p. 9.7.15) VW 60306-4:2021-12 (p. 9.7.15) VW 75209-1:2015-01 (p. 9.6.13) VW 75209-1:2021-12 (p. 9.7.11) VW 75209-2:2015-01 (p. 9.6.13) VW 75209-2:2021-12 (p. 9.7.12) VW 75210-1:2023-06 (p. 9.7.15) VW 75210-1:2024-08 (p. 9.7.15) VW 75210-2:2023-06 (p. 9.7.12) MBN LV 112-1:2016-03 (p. 9.6.15) MBN 50112-1:2023-06 (p. 12.6.15) MBN LV 112-2:2012-01 (p. 8.7.14) MBN 50112-2:2023-05 (p. 12.7.14) MBN 50216-1:2023-07 (p. 12.7.14) MBN LV 212-1:2017-08 (p. 9.6.13) MBN 50112-4:2024-06 (p. 12.6.15) MBN 50212-1:2023-04 (p. 12.7.13) GS 95007-1-1:2013-05 (p. 9.6.15) GS 95007-1-2:2013-05 (p. 9.6.15) GS 95007-3-1:2015-08 (p. 9.6.13) GS 95007-3-2:2015-09 (p. 9.6.13) GS 95007-6-1:2016-03 (p. 9.6.15) Scope of accreditation No. AB 1776 Kable, Cables Stale, wilgotne cieplo (hydroliza)\nZakres:\nKomora klimatyczna -40 °C do 175 °C,\n(85 ±5) % RH\nZakres 0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)\n0,5 kV do 6 kV D.C. LV 112-1:2013-04 (p. 9.6.15) LV 112-1:2014-04 (p. 9.6.15) LV 112-2:2007-11 (p. 8.7.14) LV 112-2:2013-04 (p. 9.6.15) LV 212-1:2015-01 (p. 9.6.13) LV 212-2:2015-01 (p. 9.6.13) LV 216-1:2015-07 (p. 9.6.15) VW 60306-1:2018-09-01 (p. 9.6.15) VW 60306-1:2021-10 (p. 9.7.15) VW 60306-2:2013-04 (p. 9.6.15) VW 60306-2:2021-11 (p. 9.7.15) VW 60306-4:2021-12 (p. 9.7.15) VW 75209-1:2015-01 (p. 9.6.13) VW 75209-1:2021-12 (p. 9.7.11) VW 75209-2:2015-01 (p. 9.6.13) VW 75209-2:2021-12 (p. 9.7.12) VW 75210-1:2023-06 (p. 9.7.15) VW 75210-1:2024-08 (p. 9.7.15) VW 75210-2:2023-06 (p. 9.7.12) MBN LV 112-1:2016-03 (p. 9.6.15) MBN 50112-1:2023-06 (p. 12.6.15) MBN LV 112-2:2012-01 (p. 8.7.14) MBN 50112-2:2023-05 (p. 12.7.14) MBN 50216-1:2023-07 (p. 12.7.14) MBN LV 212-1:2017-08 (p. 9.6.13) MBN 50112-4:2024-06 (p. 12.6.15) MBN 50212-1:2023-04 (p. 12.7.13) GS 95007-1-1:2013-05 (p. 9.6.15) GS 95007-1-2:2013-05 (p. 9.6.15) GS 95007-3-1:2015-08 (p. 9.6.13) GS 95007-3-2:2015-09 (p. 9.6.13) GS 95007-6-1:2016-03 (p. 9.6.15) Scope of accreditation No. AB 1776","categories":["other"],"row_index":85,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Damp heat, steady state (hydrolysis) Climatic chamber (85 ±5) % RH Range 0,5 kV to 6 kV D.C. LV 112-1:2013-04 (p. 9.6.15) LV 112-1:2014-04 (p. 9.6.15) LV 112-2:2007-11 (p. 8.7.14) LV 112-2:2013-04 (p. 9.6.15) LV 212-1:2015-01 (p. 9.6.13) LV 212-2:2015-01 (p. 9.6.13) LV 216-1:2015-07 (p. 9.6.15) VW 60306-1:2018-09-01 (p. 9.6.15) VW 60306-1:2021-10 (p. 9.7.15) VW 60306-2:2013-04 (p. 9.6.15) VW 60306-2:2021-11 (p. 9.7.15) VW 60306-4:2021-12 (p. 9.7.15) VW 75209-1:2015-01 (p. 9.6.13) VW 75209-1:2021-12 (p. 9.7.11) VW 75209-2:2015-01 (p. 9.6.13) VW 75209-2:2021-12 (p. 9.7.12) VW 75210-1:2023-06 (p. 9.7.15) VW 75210-1:2024-08 (p. 9.7.15) VW 75210-2:2023-06 (p. 9.7.12) MBN LV 112-1:2016-03 (p. 9.6.15) MBN 50112-1:2023-06 (p. 12.6.15) MBN LV 112-2:2012-01 (p. 8.7.14) MBN 50112-2:2023-05 (p. 12.7.14) MBN 50216-1:2023-07 (p. 12.7.14) MBN LV 212-1:2017-08 (p. 9.6.13) MBN 50112-4:2024-06 (p. 12.6.15) MBN 50212-1:2023-04 (p. 12.7.13) GS 95007-1-1:2013-05 (p. 9.6.15) GS 95007-1-2:2013-05 (p. 9.6.15) GS 95007-3-1:2015-08 (p. 9.6.13) GS 95007-3-2:2015-09 (p. 9.6.13) GS 95007-6-1:2016-03 (p. 9.6.15) Scope of accreditation No. AB 1776","parameters_zh":[{"name":"气候试验箱","range":"-40 °C do 175 °C,"},{"name":"(85 ±5) % RH"},{"name":"范围","range":"0,5 kV do 5 kV A.C. (50 Hz, 60 Hz)"},{"name":"0,5 kV do 6 kV D.C."}],"search_zh":"电缆 气候试验箱 范围 LV 112-1:2013-04 (p. 9.6.15) LV 112-1:2014-04 (p. 9.6.15) LV 112-2:2007-11 (p. 8.7.14) LV 112-2:2013-04 (p. 9.6.15) LV 212-1:2015-01 (p. 9.6.13) LV 212-2:2015-01 (p. 9.6.13) LV 216-1:2015-07 (p. 9.6.15) VW 60306-1:2018-09-01 (p. 9.6.15) VW 60306-1:2021-10 (p. 9.7.15) VW 60306-2:2013-04 (p. 9.6.15) VW 60306-2:2021-11 (p. 9.7.15) VW 60306-4:2021-12 (p. 9.7.15) VW 75209-1:2015-01 (p. 9.6.13) VW 75209-1:2021-12 (p. 9.7.11) VW 75209-2:2015-01 (p. 9.6.13) VW 75209-2:2021-12 (p. 9.7.12) VW 75210-1:2023-06 (p. 9.7.15) VW 75210-1:2024-08 (p. 9.7.15) VW 75210-2:2023-06 (p. 9.7.12) MBN LV 112-1:2016-03 (p. 9.6.15) MBN 50112-1:2023-06 (p. 12.6.15) MBN LV 112-2:2012-01 (p. 8.7.14) MBN 50112-2:2023-05 (p. 12.7.14) MBN 50216-1:2023-07 (p. 12.7.14) MBN LV 212-1:2017-08 (p. 9.6.13) MBN 50112-4:2024-06 (p. 12.6.15) MBN 50212-1:2023-04 (p. 12.7.13) GS 95007-1-1:2013-05 (p. 9.6.15) GS 95007-1-2:2013-05 (p. 9.6.15) GS 95007-3-1:2015-08 (p. 9.6.13) GS 95007-3-2:2015-09 (p. 9.6.13) GS 95007-6-1:2016-03 (p. 9.6.15) Scope of accreditation No. AB 1776","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259eee","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Odporność kabla na chemikalia i taśmy","methodology_en":"Resistance of the cable to chemicals and tapes","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność kabla na chemikalia i taśmy","reference":"LV 112-1:2013-04 (p. 9.8.2) LV 112-1:2014-04 (p. 9.8.2) LV 112-2:2007-11 (p. 8.9.2) LV 112-2:2013-04 (p. 9.8.2) LV 212-1:2015-01 (p. 9.8.2) LV 212-2:2015-01 (p. 9.8.2) LV 216-1:2015-07 (p. 9.8.2) LV 216-2:2017-02 (p. 9.8.2) VW 60306-1:2018-09-01 (p. 9.8.2) VW 60306-1:2021-10 (p. 9.9) VW 60306-2:2013-04 (p. 9.8.2) VW 60306-2:2021-11 (p. 9.9) VW 75209-1:2015-01 (p. 9.8.2) VW 75209-2:2015-01 (p. 9.8.2) VW 75209-2:2021-12 (p. 9.9) VW 75210-1:2023-06 (p. 9.9) VW 75210-1:2024-08 (p. 9.9) VW 75210-2:2023-06 (p. 9.9) MBN LV 112-1:2016-03 (p. 9.8.2) MBN 50112-1:2023-06 (p. 12.8.3) MBN LV 112-2:2012-01 (p. 8.9.2) MBN 50112-2:2023-05 (p. 12.9.2) MBN 50216-1:2023-07 (p. 12.9.2) MBN LV 212-1:2017-08 (p. 9.8.2) MBN 50212-1:2023-04 (p. 12.9.3) MBN LV 216-2:2017-07 (p. 9.8.2) MBN 50112-4:2024-06 (p. 12.8.3) GS 95007-1-1:2013-05 (p. 9.8.2) GS 95007-1-2:2013-05 (p. 9.8.2) GS 95007-3-1:2015-08 (p. 9.8.2) GS 95007-3-2:2015-09 (p. 9.8.2) GS 95007-6-1:2016-03 (p. 9.8.2) GS 95007-6-2:2017-04 (p. 9.8.2) Scope of accreditation No. AB 1776","norm_bases":["LV 112-1:2013-04 (p. 9.8.2) LV 112-1:2014-04 (p. 9.8.2) LV 112-2:2007-11 (p. 8.9.2) LV 112-2:2013-04 (p. 9.8.2) LV 212-1:2015-01 (p. 9.8.2) LV 212-2:2015-01 (p. 9.8.2) LV 216-1:2015-07 (p. 9.8.2) LV 216-2:2017-02 (p. 9.8.2) VW 60306-1:2018-09-01 (p. 9.8.2) VW 60306-1:2021-10 (p. 9.9) VW 60306-2:2013-04 (p. 9.8.2) VW 60306-2:2021-11 (p. 9.9) VW 75209-1:2015-01 (p. 9.8.2) VW 75209-2:2015-01 (p. 9.8.2) VW 75209-2:2021-12 (p. 9.9) VW 75210-1:2023-06 (p. 9.9) VW 75210-1:2024-08 (p. 9.9) VW 75210-2:2023-06 (p. 9.9) MBN LV 112-1:2016-03 (p. 9.8.2) MBN 50112-1:2023-06 (p. 12.8.3) MBN LV 112-2:2012-01 (p. 8.9.2) MBN 50112-2:2023-05 (p. 12.9.2) MBN 50216-1:2023-07 (p. 12.9.2) MBN LV 212-1:2017-08 (p. 9.8.2) MBN 50212-1:2023-04 (p. 12.9.3) MBN LV 216-2:2017-07 (p. 9.8.2) MBN 50112-4:2024-06 (p. 12.8.3) GS 95007-1-1:2013-05 (p. 9.8.2) GS 95007-1-2:2013-05 (p. 9.8.2) GS 95007-3-1:2015-08 (p. 9.8.2) GS 95007-3-2:2015-09 (p. 9.8.2) GS 95007-6-1:2016-03 (p. 9.8.2) GS 95007-6-2:2017-04 (p. 9.8.2) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Odporność kabla na chemikalia i taśmy LV 112-1:2013-04 (p. 9.8.2) LV 112-1:2014-04 (p. 9.8.2) LV 112-2:2007-11 (p. 8.9.2) LV 112-2:2013-04 (p. 9.8.2) LV 212-1:2015-01 (p. 9.8.2) LV 212-2:2015-01 (p. 9.8.2) LV 216-1:2015-07 (p. 9.8.2) LV 216-2:2017-02 (p. 9.8.2) VW 60306-1:2018-09-01 (p. 9.8.2) VW 60306-1:2021-10 (p. 9.9) VW 60306-2:2013-04 (p. 9.8.2) VW 60306-2:2021-11 (p. 9.9) VW 75209-1:2015-01 (p. 9.8.2) VW 75209-2:2015-01 (p. 9.8.2) VW 75209-2:2021-12 (p. 9.9) VW 75210-1:2023-06 (p. 9.9) VW 75210-1:2024-08 (p. 9.9) VW 75210-2:2023-06 (p. 9.9) MBN LV 112-1:2016-03 (p. 9.8.2) MBN 50112-1:2023-06 (p. 12.8.3) MBN LV 112-2:2012-01 (p. 8.9.2) MBN 50112-2:2023-05 (p. 12.9.2) MBN 50216-1:2023-07 (p. 12.9.2) MBN LV 212-1:2017-08 (p. 9.8.2) MBN 50212-1:2023-04 (p. 12.9.3) MBN LV 216-2:2017-07 (p. 9.8.2) MBN 50112-4:2024-06 (p. 12.8.3) GS 95007-1-1:2013-05 (p. 9.8.2) GS 95007-1-2:2013-05 (p. 9.8.2) GS 95007-3-1:2015-08 (p. 9.8.2) GS 95007-3-2:2015-09 (p. 9.8.2) GS 95007-6-1:2016-03 (p. 9.8.2) GS 95007-6-2:2017-04 (p. 9.8.2) Scope of accreditation No. AB 1776 Kable, Cables Odpornosc kabla na chemikalia i tasmy LV 112-1:2013-04 (p. 9.8.2) LV 112-1:2014-04 (p. 9.8.2) LV 112-2:2007-11 (p. 8.9.2) LV 112-2:2013-04 (p. 9.8.2) LV 212-1:2015-01 (p. 9.8.2) LV 212-2:2015-01 (p. 9.8.2) LV 216-1:2015-07 (p. 9.8.2) LV 216-2:2017-02 (p. 9.8.2) VW 60306-1:2018-09-01 (p. 9.8.2) VW 60306-1:2021-10 (p. 9.9) VW 60306-2:2013-04 (p. 9.8.2) VW 60306-2:2021-11 (p. 9.9) VW 75209-1:2015-01 (p. 9.8.2) VW 75209-2:2015-01 (p. 9.8.2) VW 75209-2:2021-12 (p. 9.9) VW 75210-1:2023-06 (p. 9.9) VW 75210-1:2024-08 (p. 9.9) VW 75210-2:2023-06 (p. 9.9) MBN LV 112-1:2016-03 (p. 9.8.2) MBN 50112-1:2023-06 (p. 12.8.3) MBN LV 112-2:2012-01 (p. 8.9.2) MBN 50112-2:2023-05 (p. 12.9.2) MBN 50216-1:2023-07 (p. 12.9.2) MBN LV 212-1:2017-08 (p. 9.8.2) MBN 50212-1:2023-04 (p. 12.9.3) MBN LV 216-2:2017-07 (p. 9.8.2) MBN 50112-4:2024-06 (p. 12.8.3) GS 95007-1-1:2013-05 (p. 9.8.2) GS 95007-1-2:2013-05 (p. 9.8.2) GS 95007-3-1:2015-08 (p. 9.8.2) GS 95007-3-2:2015-09 (p. 9.8.2) GS 95007-6-1:2016-03 (p. 9.8.2) GS 95007-6-2:2017-04 (p. 9.8.2) Scope of accreditation No. AB 1776","categories":["other"],"row_index":86,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Resistance of the cable to chemicals and tapes LV 112-1:2013-04 (p. 9.8.2) LV 112-1:2014-04 (p. 9.8.2) LV 112-2:2007-11 (p. 8.9.2) LV 112-2:2013-04 (p. 9.8.2) LV 212-1:2015-01 (p. 9.8.2) LV 212-2:2015-01 (p. 9.8.2) LV 216-1:2015-07 (p. 9.8.2) LV 216-2:2017-02 (p. 9.8.2) VW 60306-1:2018-09-01 (p. 9.8.2) VW 60306-1:2021-10 (p. 9.9) VW 60306-2:2013-04 (p. 9.8.2) VW 60306-2:2021-11 (p. 9.9) VW 75209-1:2015-01 (p. 9.8.2) VW 75209-2:2015-01 (p. 9.8.2) VW 75209-2:2021-12 (p. 9.9) VW 75210-1:2023-06 (p. 9.9) VW 75210-1:2024-08 (p. 9.9) VW 75210-2:2023-06 (p. 9.9) MBN LV 112-1:2016-03 (p. 9.8.2) MBN 50112-1:2023-06 (p. 12.8.3) MBN LV 112-2:2012-01 (p. 8.9.2) MBN 50112-2:2023-05 (p. 12.9.2) MBN 50216-1:2023-07 (p. 12.9.2) MBN LV 212-1:2017-08 (p. 9.8.2) MBN 50212-1:2023-04 (p. 12.9.3) MBN LV 216-2:2017-07 (p. 9.8.2) MBN 50112-4:2024-06 (p. 12.8.3) GS 95007-1-1:2013-05 (p. 9.8.2) GS 95007-1-2:2013-05 (p. 9.8.2) GS 95007-3-1:2015-08 (p. 9.8.2) GS 95007-3-2:2015-09 (p. 9.8.2) GS 95007-6-1:2016-03 (p. 9.8.2) GS 95007-6-2:2017-04 (p. 9.8.2) Scope of accreditation No. AB 1776","search_zh":"电缆 LV 112-1:2013-04 (p. 9.8.2) LV 112-1:2014-04 (p. 9.8.2) LV 112-2:2007-11 (p. 8.9.2) LV 112-2:2013-04 (p. 9.8.2) LV 212-1:2015-01 (p. 9.8.2) LV 212-2:2015-01 (p. 9.8.2) LV 216-1:2015-07 (p. 9.8.2) LV 216-2:2017-02 (p. 9.8.2) VW 60306-1:2018-09-01 (p. 9.8.2) VW 60306-1:2021-10 (p. 9.9) VW 60306-2:2013-04 (p. 9.8.2) VW 60306-2:2021-11 (p. 9.9) VW 75209-1:2015-01 (p. 9.8.2) VW 75209-2:2015-01 (p. 9.8.2) VW 75209-2:2021-12 (p. 9.9) VW 75210-1:2023-06 (p. 9.9) VW 75210-1:2024-08 (p. 9.9) VW 75210-2:2023-06 (p. 9.9) MBN LV 112-1:2016-03 (p. 9.8.2) MBN 50112-1:2023-06 (p. 12.8.3) MBN LV 112-2:2012-01 (p. 8.9.2) MBN 50112-2:2023-05 (p. 12.9.2) MBN 50216-1:2023-07 (p. 12.9.2) MBN LV 212-1:2017-08 (p. 9.8.2) MBN 50212-1:2023-04 (p. 12.9.3) MBN LV 216-2:2017-07 (p. 9.8.2) MBN 50112-4:2024-06 (p. 12.8.3) GS 95007-1-1:2013-05 (p. 9.8.2) GS 95007-1-2:2013-05 (p. 9.8.2) GS 95007-3-1:2015-08 (p. 9.8.2) GS 95007-3-2:2015-09 (p. 9.8.2) GS 95007-6-1:2016-03 (p. 9.8.2) GS 95007-6-2:2017-04 (p. 9.8.2) Scope of accreditation No. AB 1776","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259eef","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Obrazowanie widma","methodology_en":"Spectrum imaging","parameters":[{"name":"Spectrum imaging Infrared spectroscopy (FTIR)"}],"parameters_en":[{"name":"Spectrum imaging Infrared spectroscopy (FTIR)"}],"technique":"Metoda spektroskopii w podczerwieni (FTIR)","techniques":["Metoda spektroskopii w podczerwieni (FTIR)"],"technique_en":"Infrared spectroscopy method (FTIR)","computed":[],"computed_en":[],"activity":"Obrazowanie widma\nSpectrum imaging Infrared spectroscopy (FTIR)\nMetoda spektroskopii w podczerwieni (FTIR)","reference":"LV 112-1:2013-04 (p. 9.2.6; 9.6.7.2; 9.6.8.2) LV 112-1:2014-04 (p. 9.2.6; 9.6.7.2; 9.6.8.2) LV 112-2:2007-11 (p. 8.3) LV 112-2:2013-04 (p. 9.2; 9.6.7.2; 9.6.8.2) LV 122:2015-05 (p. 11.2) LV 122:2016-02 (p. 11.3) LV 212-1:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) LV 212-2:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) LV 216-1:2015-07 (p. 9.2.6; 9.6.7.2; 9.6.8.2) LV 216-2:2017-02 (p. 9.2.6; 9.6.6.2; 9.6.7.2) VW 60306-1:2021-10 (p. 9.3.7) VW 60306-2:2013-04 (p. 9.2; 9.6.7.2; 9.6.8.2) VW 60306-2:2021-11 (p. 9.3.7) VW 60306-4:2021-12 (p. 9.3.7) VW 75205:2019-11 (p. 11.2) VW 75205:2023-05 (p. 11.2) VW 75205:2024-04 (p. 11.3) VW 75209-1:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) VW 75209-1:2021-12 (p. 9.3.7) VW 75209-2:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) VW 75209-2:2021-12 (p. 9.3.6) VW 75210-1:2023-06 (p. 9.3.4) VW 75210-1:2024-08 (p. 9.3.4) VW 75210-2:2023-06 (p. 9.3.4) MBN LV 112-1:2016-03 (p. 9.2.6; 9.6.7.2; 9.6.8.2) MBN 50112-1:2023-06 (p. 12.2.7; 12.6.7.3; 12.6.8.3) MBN LV 112-2:2012-01 (p. 8.3) MBN 50112-2:2023-05 (p. 12.3) MBN 50216-1:2023-07 (p. 12.3.7; 12.7.6.3; 12.7.7.3) MBN LV 122:2017-06 (p. 11.3) MBN 50122:2023-07 (p. 13.3) MBN LV 212-1:2017-08 (p. 9.2.6; 9.6.6.2; 9.6.7.2) MBN 50212-1:2023-04 (p. 12.3.7; 12.7.6.3; 12.7.7.3) MBN LV 216-2:2017-07 (p. 9.2.6; 9.6.6.2; 9.6.7.2) MBN 50112-4:2024-06 (p. 12.2.7; 12.6.7.2; 12.6.8.2) GS 95007-1-1:2013-05 (p. 9.2.6; 9.6.7.2; 9.6.8.2) GS 95007-1-2:2013-05 (p. 9.2; 9.6.7.2; 9.6.8.2) GS 95007-1-5:2015-07 (p. 11.2) GS 95007-3-1:2015-08 (p. 9.2.6; 9.6.6.2; 9.6.7.2) GS 95007-3-2:2015-09 (p. 9.2.6; 9.6.6.2; 9.6.7.2) GS 95007-6-1:2016-03 (p. 9.2.6; 9.6.7.2; 9.6.8.2) GS 95007-6-2:2017-04 (p. 9.2.6; 9.6.6.2; 9.6.7.2) Scope of accreditation No. AB 1776","norm_bases":["LV 112-1:2013-04 (p. 9.2.6; 9.6.7.2; 9.6.8.2) LV 112-1:2014-04 (p. 9.2.6; 9.6.7.2; 9.6.8.2) LV 112-2:2007-11 (p. 8.3) LV 112-2:2013-04 (p. 9.2; 9.6.7.2; 9.6.8.2) LV 122:2015-05 (p. 11.2) LV 122:2016-02 (p. 11.3) LV 212-1:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) LV 212-2:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) LV 216-1:2015-07 (p. 9.2.6; 9.6.7.2; 9.6.8.2) LV 216-2:2017-02 (p. 9.2.6; 9.6.6.2; 9.6.7.2) VW 60306-1:2021-10 (p. 9.3.7) VW 60306-2:2013-04 (p. 9.2; 9.6.7.2; 9.6.8.2) VW 60306-2:2021-11 (p. 9.3.7) VW 60306-4:2021-12 (p. 9.3.7) VW 75205:2019-11 (p. 11.2) VW 75205:2023-05 (p. 11.2) VW 75205:2024-04 (p. 11.3) VW 75209-1:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) VW 75209-1:2021-12 (p. 9.3.7) VW 75209-2:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) VW 75209-2:2021-12 (p. 9.3.6) VW 75210-1:2023-06 (p. 9.3.4) VW 75210-1:2024-08 (p. 9.3.4) VW 75210-2:2023-06 (p. 9.3.4) MBN LV 112-1:2016-03 (p. 9.2.6; 9.6.7.2; 9.6.8.2) MBN 50112-1:2023-06 (p. 12.2.7; 12.6.7.3; 12.6.8.3) MBN LV 112-2:2012-01 (p. 8.3) MBN 50112-2:2023-05 (p. 12.3) MBN 50216-1:2023-07 (p. 12.3.7; 12.7.6.3; 12.7.7.3) MBN LV 122:2017-06 (p. 11.3) MBN 50122:2023-07 (p. 13.3) MBN LV 212-1:2017-08 (p. 9.2.6; 9.6.6.2; 9.6.7.2) MBN 50212-1:2023-04 (p. 12.3.7; 12.7.6.3; 12.7.7.3) MBN LV 216-2:2017-07 (p. 9.2.6; 9.6.6.2; 9.6.7.2) MBN 50112-4:2024-06 (p. 12.2.7; 12.6.7.2; 12.6.8.2) GS 95007-1-1:2013-05 (p. 9.2.6; 9.6.7.2; 9.6.8.2) GS 95007-1-2:2013-05 (p. 9.2; 9.6.7.2; 9.6.8.2) GS 95007-1-5:2015-07 (p. 11.2) GS 95007-3-1:2015-08 (p. 9.2.6; 9.6.6.2; 9.6.7.2) GS 95007-3-2:2015-09 (p. 9.2.6; 9.6.6.2; 9.6.7.2) GS 95007-6-1:2016-03 (p. 9.2.6; 9.6.7.2; 9.6.8.2) GS 95007-6-2:2017-04 (p. 9.2.6; 9.6.6.2; 9.6.7.2) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Obrazowanie widma\nSpectrum imaging Infrared spectroscopy (FTIR)\nMetoda spektroskopii w podczerwieni (FTIR) LV 112-1:2013-04 (p. 9.2.6; 9.6.7.2; 9.6.8.2) LV 112-1:2014-04 (p. 9.2.6; 9.6.7.2; 9.6.8.2) LV 112-2:2007-11 (p. 8.3) LV 112-2:2013-04 (p. 9.2; 9.6.7.2; 9.6.8.2) LV 122:2015-05 (p. 11.2) LV 122:2016-02 (p. 11.3) LV 212-1:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) LV 212-2:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) LV 216-1:2015-07 (p. 9.2.6; 9.6.7.2; 9.6.8.2) LV 216-2:2017-02 (p. 9.2.6; 9.6.6.2; 9.6.7.2) VW 60306-1:2021-10 (p. 9.3.7) VW 60306-2:2013-04 (p. 9.2; 9.6.7.2; 9.6.8.2) VW 60306-2:2021-11 (p. 9.3.7) VW 60306-4:2021-12 (p. 9.3.7) VW 75205:2019-11 (p. 11.2) VW 75205:2023-05 (p. 11.2) VW 75205:2024-04 (p. 11.3) VW 75209-1:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) VW 75209-1:2021-12 (p. 9.3.7) VW 75209-2:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) VW 75209-2:2021-12 (p. 9.3.6) VW 75210-1:2023-06 (p. 9.3.4) VW 75210-1:2024-08 (p. 9.3.4) VW 75210-2:2023-06 (p. 9.3.4) MBN LV 112-1:2016-03 (p. 9.2.6; 9.6.7.2; 9.6.8.2) MBN 50112-1:2023-06 (p. 12.2.7; 12.6.7.3; 12.6.8.3) MBN LV 112-2:2012-01 (p. 8.3) MBN 50112-2:2023-05 (p. 12.3) MBN 50216-1:2023-07 (p. 12.3.7; 12.7.6.3; 12.7.7.3) MBN LV 122:2017-06 (p. 11.3) MBN 50122:2023-07 (p. 13.3) MBN LV 212-1:2017-08 (p. 9.2.6; 9.6.6.2; 9.6.7.2) MBN 50212-1:2023-04 (p. 12.3.7; 12.7.6.3; 12.7.7.3) MBN LV 216-2:2017-07 (p. 9.2.6; 9.6.6.2; 9.6.7.2) MBN 50112-4:2024-06 (p. 12.2.7; 12.6.7.2; 12.6.8.2) GS 95007-1-1:2013-05 (p. 9.2.6; 9.6.7.2; 9.6.8.2) GS 95007-1-2:2013-05 (p. 9.2; 9.6.7.2; 9.6.8.2) GS 95007-1-5:2015-07 (p. 11.2) GS 95007-3-1:2015-08 (p. 9.2.6; 9.6.6.2; 9.6.7.2) GS 95007-3-2:2015-09 (p. 9.2.6; 9.6.6.2; 9.6.7.2) GS 95007-6-1:2016-03 (p. 9.2.6; 9.6.7.2; 9.6.8.2) GS 95007-6-2:2017-04 (p. 9.2.6; 9.6.6.2; 9.6.7.2) Scope of accreditation No. AB 1776 Kable, Cables Obrazowanie widma\nSpectrum imaging Infrared spectroscopy (FTIR)\nMetoda spektroskopii w podczerwieni (FTIR) LV 112-1:2013-04 (p. 9.2.6; 9.6.7.2; 9.6.8.2) LV 112-1:2014-04 (p. 9.2.6; 9.6.7.2; 9.6.8.2) LV 112-2:2007-11 (p. 8.3) LV 112-2:2013-04 (p. 9.2; 9.6.7.2; 9.6.8.2) LV 122:2015-05 (p. 11.2) LV 122:2016-02 (p. 11.3) LV 212-1:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) LV 212-2:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) LV 216-1:2015-07 (p. 9.2.6; 9.6.7.2; 9.6.8.2) LV 216-2:2017-02 (p. 9.2.6; 9.6.6.2; 9.6.7.2) VW 60306-1:2021-10 (p. 9.3.7) VW 60306-2:2013-04 (p. 9.2; 9.6.7.2; 9.6.8.2) VW 60306-2:2021-11 (p. 9.3.7) VW 60306-4:2021-12 (p. 9.3.7) VW 75205:2019-11 (p. 11.2) VW 75205:2023-05 (p. 11.2) VW 75205:2024-04 (p. 11.3) VW 75209-1:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) VW 75209-1:2021-12 (p. 9.3.7) VW 75209-2:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) VW 75209-2:2021-12 (p. 9.3.6) VW 75210-1:2023-06 (p. 9.3.4) VW 75210-1:2024-08 (p. 9.3.4) VW 75210-2:2023-06 (p. 9.3.4) MBN LV 112-1:2016-03 (p. 9.2.6; 9.6.7.2; 9.6.8.2) MBN 50112-1:2023-06 (p. 12.2.7; 12.6.7.3; 12.6.8.3) MBN LV 112-2:2012-01 (p. 8.3) MBN 50112-2:2023-05 (p. 12.3) MBN 50216-1:2023-07 (p. 12.3.7; 12.7.6.3; 12.7.7.3) MBN LV 122:2017-06 (p. 11.3) MBN 50122:2023-07 (p. 13.3) MBN LV 212-1:2017-08 (p. 9.2.6; 9.6.6.2; 9.6.7.2) MBN 50212-1:2023-04 (p. 12.3.7; 12.7.6.3; 12.7.7.3) MBN LV 216-2:2017-07 (p. 9.2.6; 9.6.6.2; 9.6.7.2) MBN 50112-4:2024-06 (p. 12.2.7; 12.6.7.2; 12.6.8.2) GS 95007-1-1:2013-05 (p. 9.2.6; 9.6.7.2; 9.6.8.2) GS 95007-1-2:2013-05 (p. 9.2; 9.6.7.2; 9.6.8.2) GS 95007-1-5:2015-07 (p. 11.2) GS 95007-3-1:2015-08 (p. 9.2.6; 9.6.6.2; 9.6.7.2) GS 95007-3-2:2015-09 (p. 9.2.6; 9.6.6.2; 9.6.7.2) GS 95007-6-1:2016-03 (p. 9.2.6; 9.6.7.2; 9.6.8.2) GS 95007-6-2:2017-04 (p. 9.2.6; 9.6.6.2; 9.6.7.2) Scope of accreditation No. AB 1776","categories":["other"],"row_index":87,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Spectrum imaging Infrared spectroscopy method (FTIR) Spectrum imaging Infrared spectroscopy (FTIR) LV 112-1:2013-04 (p. 9.2.6; 9.6.7.2; 9.6.8.2) LV 112-1:2014-04 (p. 9.2.6; 9.6.7.2; 9.6.8.2) LV 112-2:2007-11 (p. 8.3) LV 112-2:2013-04 (p. 9.2; 9.6.7.2; 9.6.8.2) LV 122:2015-05 (p. 11.2) LV 122:2016-02 (p. 11.3) LV 212-1:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) LV 212-2:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) LV 216-1:2015-07 (p. 9.2.6; 9.6.7.2; 9.6.8.2) LV 216-2:2017-02 (p. 9.2.6; 9.6.6.2; 9.6.7.2) VW 60306-1:2021-10 (p. 9.3.7) VW 60306-2:2013-04 (p. 9.2; 9.6.7.2; 9.6.8.2) VW 60306-2:2021-11 (p. 9.3.7) VW 60306-4:2021-12 (p. 9.3.7) VW 75205:2019-11 (p. 11.2) VW 75205:2023-05 (p. 11.2) VW 75205:2024-04 (p. 11.3) VW 75209-1:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) VW 75209-1:2021-12 (p. 9.3.7) VW 75209-2:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) VW 75209-2:2021-12 (p. 9.3.6) VW 75210-1:2023-06 (p. 9.3.4) VW 75210-1:2024-08 (p. 9.3.4) VW 75210-2:2023-06 (p. 9.3.4) MBN LV 112-1:2016-03 (p. 9.2.6; 9.6.7.2; 9.6.8.2) MBN 50112-1:2023-06 (p. 12.2.7; 12.6.7.3; 12.6.8.3) MBN LV 112-2:2012-01 (p. 8.3) MBN 50112-2:2023-05 (p. 12.3) MBN 50216-1:2023-07 (p. 12.3.7; 12.7.6.3; 12.7.7.3) MBN LV 122:2017-06 (p. 11.3) MBN 50122:2023-07 (p. 13.3) MBN LV 212-1:2017-08 (p. 9.2.6; 9.6.6.2; 9.6.7.2) MBN 50212-1:2023-04 (p. 12.3.7; 12.7.6.3; 12.7.7.3) MBN LV 216-2:2017-07 (p. 9.2.6; 9.6.6.2; 9.6.7.2) MBN 50112-4:2024-06 (p. 12.2.7; 12.6.7.2; 12.6.8.2) GS 95007-1-1:2013-05 (p. 9.2.6; 9.6.7.2; 9.6.8.2) GS 95007-1-2:2013-05 (p. 9.2; 9.6.7.2; 9.6.8.2) GS 95007-1-5:2015-07 (p. 11.2) GS 95007-3-1:2015-08 (p. 9.2.6; 9.6.6.2; 9.6.7.2) GS 95007-3-2:2015-09 (p. 9.2.6; 9.6.6.2; 9.6.7.2) GS 95007-6-1:2016-03 (p. 9.2.6; 9.6.7.2; 9.6.8.2) GS 95007-6-2:2017-04 (p. 9.2.6; 9.6.6.2; 9.6.7.2) Scope of accreditation No. AB 1776","search_zh":"电缆 LV 112-1:2013-04 (p. 9.2.6; 9.6.7.2; 9.6.8.2) LV 112-1:2014-04 (p. 9.2.6; 9.6.7.2; 9.6.8.2) LV 112-2:2007-11 (p. 8.3) LV 112-2:2013-04 (p. 9.2; 9.6.7.2; 9.6.8.2) LV 122:2015-05 (p. 11.2) LV 122:2016-02 (p. 11.3) LV 212-1:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) LV 212-2:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) LV 216-1:2015-07 (p. 9.2.6; 9.6.7.2; 9.6.8.2) LV 216-2:2017-02 (p. 9.2.6; 9.6.6.2; 9.6.7.2) VW 60306-1:2021-10 (p. 9.3.7) VW 60306-2:2013-04 (p. 9.2; 9.6.7.2; 9.6.8.2) VW 60306-2:2021-11 (p. 9.3.7) VW 60306-4:2021-12 (p. 9.3.7) VW 75205:2019-11 (p. 11.2) VW 75205:2023-05 (p. 11.2) VW 75205:2024-04 (p. 11.3) VW 75209-1:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) VW 75209-1:2021-12 (p. 9.3.7) VW 75209-2:2015-01 (p. 9.2.6; 9.6.6.2; 9.6.7.2) VW 75209-2:2021-12 (p. 9.3.6) VW 75210-1:2023-06 (p. 9.3.4) VW 75210-1:2024-08 (p. 9.3.4) VW 75210-2:2023-06 (p. 9.3.4) MBN LV 112-1:2016-03 (p. 9.2.6; 9.6.7.2; 9.6.8.2) MBN 50112-1:2023-06 (p. 12.2.7; 12.6.7.3; 12.6.8.3) MBN LV 112-2:2012-01 (p. 8.3) MBN 50112-2:2023-05 (p. 12.3) MBN 50216-1:2023-07 (p. 12.3.7; 12.7.6.3; 12.7.7.3) MBN LV 122:2017-06 (p. 11.3) MBN 50122:2023-07 (p. 13.3) MBN LV 212-1:2017-08 (p. 9.2.6; 9.6.6.2; 9.6.7.2) MBN 50212-1:2023-04 (p. 12.3.7; 12.7.6.3; 12.7.7.3) MBN LV 216-2:2017-07 (p. 9.2.6; 9.6.6.2; 9.6.7.2) MBN 50112-4:2024-06 (p. 12.2.7; 12.6.7.2; 12.6.8.2) GS 95007-1-1:2013-05 (p. 9.2.6; 9.6.7.2; 9.6.8.2) GS 95007-1-2:2013-05 (p. 9.2; 9.6.7.2; 9.6.8.2) GS 95007-1-5:2015-07 (p. 11.2) GS 95007-3-1:2015-08 (p. 9.2.6; 9.6.6.2; 9.6.7.2) GS 95007-3-2:2015-09 (p. 9.2.6; 9.6.6.2; 9.6.7.2) GS 95007-6-1:2016-03 (p. 9.2.6; 9.6.7.2; 9.6.8.2) GS 95007-6-2:2017-04 (p. 9.2.6; 9.6.6.2; 9.6.7.2) Scope of accreditation No. AB 1776","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ef0","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Właściwości ślizgowe kabli","methodology_en":"Sliding properties of cables","parameters":[{"name":"Odważniki","range":"5 N, 10 N"},{"name":"Średnice rolek","range":"20 mm, 30 mm, 40 mm,"},{"name":"Zakres","range":"50 mm, 60 mm, 80 mm"}],"parameters_en":[{"name":"Weights","range":"5 N, 10 N"},{"name":"Roller diameters","range":"20 mm, 30 mm, 40 mm,"},{"name":"Range","range":"50 mm, 60 mm, 80 mm"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Właściwości ślizgowe kabli\nZakres:\nOdważniki 5 N, 10 N\nŚrednice rolek 20 mm, 30 mm, 40 mm,\nZakres 50 mm, 60 mm, 80 mm","reference":"LV 112-1:2013-04 (p. 9.3.3) LV 112-1:2014-04 (p. 9.3.3) LV 112-2:2007-11 (p. 8.4.4) LV 112-2:2013-04 (p. 9.3.3) LV 212-1:2015-01 (p. 9.3.3) LV 212-2:2015-01 (p. 9.3.3) LV 216-1:2015-07 (p. 9.3.3) LV 216-2:2017-02 (p. 9.3.3) VW 60306-2:2013-04 (p. 9.3.3) VW 75209-1:2015-01 (p. 9.3.3) VW 75209-2:2015-01 (p. 9.3.3) MBN LV 112-1:2016-03 (p. 9.3.3) MBN 50112-1:2023-06 (p. 12.3.4) MBN LV 112-2:2012-01 (p. 8.4.4) MBN 50112-2:2023-05 (p. 12.4.4) MBN 50216-1:2023-07 (p. 12.4.4) MBN LV 212-1:2017-08 (p. 9.3.3) MBN 50212-1:2023-04 (p. 12.4.3) MBN LV 216-2:2017-07 (p. 9.3.3) MBN 50112-4:2024-06 (p. 12.3.5) GS 95007-1-1:2013-05 (p. 9.3.3) GS 95007-1-2:2013-05 (p. 9.3.3) GS 95007-3-1:2015-08 (p. 9.3.3) GS 95007-3-2:2015-09 (p. 9.3.3) GS 95007-6-1:2016-03 (p. 9.3.3) GS 95007-6-2:2017-04 (p. 9.3.3)","norm_bases":["LV 112-1:2013-04 (p. 9.3.3) LV 112-1:2014-04 (p. 9.3.3) LV 112-2:2007-11 (p. 8.4.4) LV 112-2:2013-04 (p. 9.3.3) LV 212-1:2015-01 (p. 9.3.3) LV 212-2:2015-01 (p. 9.3.3) LV 216-1:2015-07 (p. 9.3.3) LV 216-2:2017-02 (p. 9.3.3) VW 60306-2:2013-04 (p. 9.3.3) VW 75209-1:2015-01 (p. 9.3.3) VW 75209-2:2015-01 (p. 9.3.3) MBN LV 112-1:2016-03 (p. 9.3.3) MBN 50112-1:2023-06 (p. 12.3.4) MBN LV 112-2:2012-01 (p. 8.4.4) MBN 50112-2:2023-05 (p. 12.4.4) MBN 50216-1:2023-07 (p. 12.4.4) MBN LV 212-1:2017-08 (p. 9.3.3) MBN 50212-1:2023-04 (p. 12.4.3) MBN LV 216-2:2017-07 (p. 9.3.3) MBN 50112-4:2024-06 (p. 12.3.5) GS 95007-1-1:2013-05 (p. 9.3.3) GS 95007-1-2:2013-05 (p. 9.3.3) GS 95007-3-1:2015-08 (p. 9.3.3) GS 95007-3-2:2015-09 (p. 9.3.3) GS 95007-6-1:2016-03 (p. 9.3.3) GS 95007-6-2:2017-04 (p. 9.3.3)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Właściwości ślizgowe kabli\nZakres:\nOdważniki 5 N, 10 N\nŚrednice rolek 20 mm, 30 mm, 40 mm,\nZakres 50 mm, 60 mm, 80 mm LV 112-1:2013-04 (p. 9.3.3) LV 112-1:2014-04 (p. 9.3.3) LV 112-2:2007-11 (p. 8.4.4) LV 112-2:2013-04 (p. 9.3.3) LV 212-1:2015-01 (p. 9.3.3) LV 212-2:2015-01 (p. 9.3.3) LV 216-1:2015-07 (p. 9.3.3) LV 216-2:2017-02 (p. 9.3.3) VW 60306-2:2013-04 (p. 9.3.3) VW 75209-1:2015-01 (p. 9.3.3) VW 75209-2:2015-01 (p. 9.3.3) MBN LV 112-1:2016-03 (p. 9.3.3) MBN 50112-1:2023-06 (p. 12.3.4) MBN LV 112-2:2012-01 (p. 8.4.4) MBN 50112-2:2023-05 (p. 12.4.4) MBN 50216-1:2023-07 (p. 12.4.4) MBN LV 212-1:2017-08 (p. 9.3.3) MBN 50212-1:2023-04 (p. 12.4.3) MBN LV 216-2:2017-07 (p. 9.3.3) MBN 50112-4:2024-06 (p. 12.3.5) GS 95007-1-1:2013-05 (p. 9.3.3) GS 95007-1-2:2013-05 (p. 9.3.3) GS 95007-3-1:2015-08 (p. 9.3.3) GS 95007-3-2:2015-09 (p. 9.3.3) GS 95007-6-1:2016-03 (p. 9.3.3) GS 95007-6-2:2017-04 (p. 9.3.3) Kable, Cables Wlasciwosci slizgowe kabli\nZakres:\nOdwazniki 5 N, 10 N\nSrednice rolek 20 mm, 30 mm, 40 mm,\nZakres 50 mm, 60 mm, 80 mm LV 112-1:2013-04 (p. 9.3.3) LV 112-1:2014-04 (p. 9.3.3) LV 112-2:2007-11 (p. 8.4.4) LV 112-2:2013-04 (p. 9.3.3) LV 212-1:2015-01 (p. 9.3.3) LV 212-2:2015-01 (p. 9.3.3) LV 216-1:2015-07 (p. 9.3.3) LV 216-2:2017-02 (p. 9.3.3) VW 60306-2:2013-04 (p. 9.3.3) VW 75209-1:2015-01 (p. 9.3.3) VW 75209-2:2015-01 (p. 9.3.3) MBN LV 112-1:2016-03 (p. 9.3.3) MBN 50112-1:2023-06 (p. 12.3.4) MBN LV 112-2:2012-01 (p. 8.4.4) MBN 50112-2:2023-05 (p. 12.4.4) MBN 50216-1:2023-07 (p. 12.4.4) MBN LV 212-1:2017-08 (p. 9.3.3) MBN 50212-1:2023-04 (p. 12.4.3) MBN LV 216-2:2017-07 (p. 9.3.3) MBN 50112-4:2024-06 (p. 12.3.5) GS 95007-1-1:2013-05 (p. 9.3.3) GS 95007-1-2:2013-05 (p. 9.3.3) GS 95007-3-1:2015-08 (p. 9.3.3) GS 95007-3-2:2015-09 (p. 9.3.3) GS 95007-6-1:2016-03 (p. 9.3.3) GS 95007-6-2:2017-04 (p. 9.3.3)","categories":["other"],"row_index":88,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Sliding properties of cables Weights Roller diameters Range LV 112-1:2013-04 (p. 9.3.3) LV 112-1:2014-04 (p. 9.3.3) LV 112-2:2007-11 (p. 8.4.4) LV 112-2:2013-04 (p. 9.3.3) LV 212-1:2015-01 (p. 9.3.3) LV 212-2:2015-01 (p. 9.3.3) LV 216-1:2015-07 (p. 9.3.3) LV 216-2:2017-02 (p. 9.3.3) VW 60306-2:2013-04 (p. 9.3.3) VW 75209-1:2015-01 (p. 9.3.3) VW 75209-2:2015-01 (p. 9.3.3) MBN LV 112-1:2016-03 (p. 9.3.3) MBN 50112-1:2023-06 (p. 12.3.4) MBN LV 112-2:2012-01 (p. 8.4.4) MBN 50112-2:2023-05 (p. 12.4.4) MBN 50216-1:2023-07 (p. 12.4.4) MBN LV 212-1:2017-08 (p. 9.3.3) MBN 50212-1:2023-04 (p. 12.4.3) MBN LV 216-2:2017-07 (p. 9.3.3) MBN 50112-4:2024-06 (p. 12.3.5) GS 95007-1-1:2013-05 (p. 9.3.3) GS 95007-1-2:2013-05 (p. 9.3.3) GS 95007-3-1:2015-08 (p. 9.3.3) GS 95007-3-2:2015-09 (p. 9.3.3) GS 95007-6-1:2016-03 (p. 9.3.3) GS 95007-6-2:2017-04 (p. 9.3.3)","parameters_zh":[{"name":"Odważniki","range":"5 N, 10 N"},{"name":"Średnice rolek","range":"20 mm, 30 mm, 40 mm,"},{"name":"范围","range":"50 mm, 60 mm, 80 mm"}],"search_zh":"电缆 范围 LV 112-1:2013-04 (p. 9.3.3) LV 112-1:2014-04 (p. 9.3.3) LV 112-2:2007-11 (p. 8.4.4) LV 112-2:2013-04 (p. 9.3.3) LV 212-1:2015-01 (p. 9.3.3) LV 212-2:2015-01 (p. 9.3.3) LV 216-1:2015-07 (p. 9.3.3) LV 216-2:2017-02 (p. 9.3.3) VW 60306-2:2013-04 (p. 9.3.3) VW 75209-1:2015-01 (p. 9.3.3) VW 75209-2:2015-01 (p. 9.3.3) MBN LV 112-1:2016-03 (p. 9.3.3) MBN 50112-1:2023-06 (p. 12.3.4) MBN LV 112-2:2012-01 (p. 8.4.4) MBN 50112-2:2023-05 (p. 12.4.4) MBN 50216-1:2023-07 (p. 12.4.4) MBN LV 212-1:2017-08 (p. 9.3.3) MBN 50212-1:2023-04 (p. 12.4.3) MBN LV 216-2:2017-07 (p. 9.3.3) MBN 50112-4:2024-06 (p. 12.3.5) GS 95007-1-1:2013-05 (p. 9.3.3) GS 95007-1-2:2013-05 (p. 9.3.3) GS 95007-3-1:2015-08 (p. 9.3.3) GS 95007-3-2:2015-09 (p. 9.3.3) GS 95007-6-1:2016-03 (p. 9.3.3) GS 95007-6-2:2017-04 (p. 9.3.3)","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ef1","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Sprawdzenie budowy kabla","methodology_en":"Verification of the cable construction","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Sprawdzenie budowy kabla","reference":"LV 212-1:2015-01 (p. 9.1) LV 212-2:2015-01 (p. 9.1) LV 216-1:2015-07 (p. 9.1) LV 216-2:2017-02 (p. 9.1) VW 75209-1:2015-01 (p. 9.1) VW 75209-1:2021-12 (p. 9.2.1) VW 75209-2:2015-01 (p. 9.1) VW 75210-1:2023-06 (p. 9.2) VW 75210-1:2024-08 (p. 9.2.1) VW 75210-2:2023-06 (p. 9.2.2) MBN LV 212-1:2017-08 (p. 9.1) MBN LV 216-2:2017-07 (p. 9.1) MBN 50216-1:2023-07 (p. 12.2) GS 95007-3-1:2015-08 (p. 9.1) GS 95007-3-2:2015-09 (p. 9.1) GS 95007-6-1:2016-03 (p. 9.1) GS 95007-6-2:2017-04 (p. 9.1)","norm_bases":["LV 212-1:2015-01 (p. 9.1) LV 212-2:2015-01 (p. 9.1) LV 216-1:2015-07 (p. 9.1) LV 216-2:2017-02 (p. 9.1) VW 75209-1:2015-01 (p. 9.1) VW 75209-1:2021-12 (p. 9.2.1) VW 75209-2:2015-01 (p. 9.1) VW 75210-1:2023-06 (p. 9.2) VW 75210-1:2024-08 (p. 9.2.1) VW 75210-2:2023-06 (p. 9.2.2) MBN LV 212-1:2017-08 (p. 9.1) MBN LV 216-2:2017-07 (p. 9.1) MBN 50216-1:2023-07 (p. 12.2) GS 95007-3-1:2015-08 (p. 9.1) GS 95007-3-2:2015-09 (p. 9.1) GS 95007-6-1:2016-03 (p. 9.1) GS 95007-6-2:2017-04 (p. 9.1)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Sprawdzenie budowy kabla LV 212-1:2015-01 (p. 9.1) LV 212-2:2015-01 (p. 9.1) LV 216-1:2015-07 (p. 9.1) LV 216-2:2017-02 (p. 9.1) VW 75209-1:2015-01 (p. 9.1) VW 75209-1:2021-12 (p. 9.2.1) VW 75209-2:2015-01 (p. 9.1) VW 75210-1:2023-06 (p. 9.2) VW 75210-1:2024-08 (p. 9.2.1) VW 75210-2:2023-06 (p. 9.2.2) MBN LV 212-1:2017-08 (p. 9.1) MBN LV 216-2:2017-07 (p. 9.1) MBN 50216-1:2023-07 (p. 12.2) GS 95007-3-1:2015-08 (p. 9.1) GS 95007-3-2:2015-09 (p. 9.1) GS 95007-6-1:2016-03 (p. 9.1) GS 95007-6-2:2017-04 (p. 9.1) Kable, Cables Sprawdzenie budowy kabla LV 212-1:2015-01 (p. 9.1) LV 212-2:2015-01 (p. 9.1) LV 216-1:2015-07 (p. 9.1) LV 216-2:2017-02 (p. 9.1) VW 75209-1:2015-01 (p. 9.1) VW 75209-1:2021-12 (p. 9.2.1) VW 75209-2:2015-01 (p. 9.1) VW 75210-1:2023-06 (p. 9.2) VW 75210-1:2024-08 (p. 9.2.1) VW 75210-2:2023-06 (p. 9.2.2) MBN LV 212-1:2017-08 (p. 9.1) MBN LV 216-2:2017-07 (p. 9.1) MBN 50216-1:2023-07 (p. 12.2) GS 95007-3-1:2015-08 (p. 9.1) GS 95007-3-2:2015-09 (p. 9.1) GS 95007-6-1:2016-03 (p. 9.1) GS 95007-6-2:2017-04 (p. 9.1)","categories":["other"],"row_index":89,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Verification of the cable construction LV 212-1:2015-01 (p. 9.1) LV 212-2:2015-01 (p. 9.1) LV 216-1:2015-07 (p. 9.1) LV 216-2:2017-02 (p. 9.1) VW 75209-1:2015-01 (p. 9.1) VW 75209-1:2021-12 (p. 9.2.1) VW 75209-2:2015-01 (p. 9.1) VW 75210-1:2023-06 (p. 9.2) VW 75210-1:2024-08 (p. 9.2.1) VW 75210-2:2023-06 (p. 9.2.2) MBN LV 212-1:2017-08 (p. 9.1) MBN LV 216-2:2017-07 (p. 9.1) MBN 50216-1:2023-07 (p. 12.2) GS 95007-3-1:2015-08 (p. 9.1) GS 95007-3-2:2015-09 (p. 9.1) GS 95007-6-1:2016-03 (p. 9.1) GS 95007-6-2:2017-04 (p. 9.1)","search_zh":"电缆 LV 212-1:2015-01 (p. 9.1) LV 212-2:2015-01 (p. 9.1) LV 216-1:2015-07 (p. 9.1) LV 216-2:2017-02 (p. 9.1) VW 75209-1:2015-01 (p. 9.1) VW 75209-1:2021-12 (p. 9.2.1) VW 75209-2:2015-01 (p. 9.1) VW 75210-1:2023-06 (p. 9.2) VW 75210-1:2024-08 (p. 9.2.1) VW 75210-2:2023-06 (p. 9.2.2) MBN LV 212-1:2017-08 (p. 9.1) MBN LV 216-2:2017-07 (p. 9.1) MBN 50216-1:2023-07 (p. 12.2) GS 95007-3-1:2015-08 (p. 9.1) GS 95007-3-2:2015-09 (p. 9.1) GS 95007-6-1:2016-03 (p. 9.1) GS 95007-6-2:2017-04 (p. 9.1)","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ef2","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Minimalna grubość ścianki kabli skręconych","methodology_en":"Minimum wall thickness of twisted cables","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Minimalna grubość ścianki kabli skręconych","reference":"LV 122:2015-05 (p. 11.1.1) LV 122:2016-02 (p. 11.2.1) VW 75205:2019-11 (p. 11.1.1) VW 75205:2024-04 (p. 11.2.2) VW 75205:2023-05 (p. 11.1.1) MBN LV 122:2017-06 (p. 11.2.1) MBN 50122:2023-07 (p. 13.2.2) GS 95007-1-5:2015-07 (p. 11.1.1) Scope of accreditation No. AB 1776","norm_bases":["LV 122:2015-05 (p. 11.1.1) LV 122:2016-02 (p. 11.2.1) VW 75205:2019-11 (p. 11.1.1) VW 75205:2024-04 (p. 11.2.2) VW 75205:2023-05 (p. 11.1.1) MBN LV 122:2017-06 (p. 11.2.1) MBN 50122:2023-07 (p. 13.2.2) GS 95007-1-5:2015-07 (p. 11.1.1) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Minimalna grubość ścianki kabli skręconych LV 122:2015-05 (p. 11.1.1) LV 122:2016-02 (p. 11.2.1) VW 75205:2019-11 (p. 11.1.1) VW 75205:2024-04 (p. 11.2.2) VW 75205:2023-05 (p. 11.1.1) MBN LV 122:2017-06 (p. 11.2.1) MBN 50122:2023-07 (p. 13.2.2) GS 95007-1-5:2015-07 (p. 11.1.1) Scope of accreditation No. AB 1776 Kable, Cables Minimalna grubosc scianki kabli skreconych LV 122:2015-05 (p. 11.1.1) LV 122:2016-02 (p. 11.2.1) VW 75205:2019-11 (p. 11.1.1) VW 75205:2024-04 (p. 11.2.2) VW 75205:2023-05 (p. 11.1.1) MBN LV 122:2017-06 (p. 11.2.1) MBN 50122:2023-07 (p. 13.2.2) GS 95007-1-5:2015-07 (p. 11.1.1) Scope of accreditation No. AB 1776","categories":["other"],"row_index":90,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Minimum wall thickness of twisted cables LV 122:2015-05 (p. 11.1.1) LV 122:2016-02 (p. 11.2.1) VW 75205:2019-11 (p. 11.1.1) VW 75205:2024-04 (p. 11.2.2) VW 75205:2023-05 (p. 11.1.1) MBN LV 122:2017-06 (p. 11.2.1) MBN 50122:2023-07 (p. 13.2.2) GS 95007-1-5:2015-07 (p. 11.1.1) Scope of accreditation No. AB 1776","search_zh":"电缆 LV 122:2015-05 (p. 11.1.1) LV 122:2016-02 (p. 11.2.1) VW 75205:2019-11 (p. 11.1.1) VW 75205:2024-04 (p. 11.2.2) VW 75205:2023-05 (p. 11.1.1) MBN LV 122:2017-06 (p. 11.2.1) MBN 50122:2023-07 (p. 13.2.2) GS 95007-1-5:2015-07 (p. 11.1.1) Scope of accreditation No. AB 1776","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ef3","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Średnica zewnętrzna kabli skręconych (kalkulowana)","methodology_en":"External diameter of stranded cables (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Średnica zewnętrzna kabli skręconych (kalkulowana)","reference":"LV 122:2015-05 (p. 11.1.2) LV 122:2016-02 (p. 11.2.2) VW 75205:2019-11 (p. 11.1.2) VW 75205:2023-05 (p. 11.1.2) VW 75205:2024-04 (p. 11.2.3) MBN LV 122:2017-06 (p. 11.2.2) MBN 50122:2023-07 (p. 13.2.3) GS 95007-1-5:2015-07 (p. 11.1.2)","norm_bases":["LV 122:2015-05 (p. 11.1.2) LV 122:2016-02 (p. 11.2.2) VW 75205:2019-11 (p. 11.1.2) VW 75205:2023-05 (p. 11.1.2) VW 75205:2024-04 (p. 11.2.3) MBN LV 122:2017-06 (p. 11.2.2) MBN 50122:2023-07 (p. 13.2.3) GS 95007-1-5:2015-07 (p. 11.1.2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Średnica zewnętrzna kabli skręconych (kalkulowana) LV 122:2015-05 (p. 11.1.2) LV 122:2016-02 (p. 11.2.2) VW 75205:2019-11 (p. 11.1.2) VW 75205:2023-05 (p. 11.1.2) VW 75205:2024-04 (p. 11.2.3) MBN LV 122:2017-06 (p. 11.2.2) MBN 50122:2023-07 (p. 13.2.3) GS 95007-1-5:2015-07 (p. 11.1.2) Kable, Cables Srednica zewnetrzna kabli skreconych (kalkulowana) LV 122:2015-05 (p. 11.1.2) LV 122:2016-02 (p. 11.2.2) VW 75205:2019-11 (p. 11.1.2) VW 75205:2023-05 (p. 11.1.2) VW 75205:2024-04 (p. 11.2.3) MBN LV 122:2017-06 (p. 11.2.2) MBN 50122:2023-07 (p. 13.2.3) GS 95007-1-5:2015-07 (p. 11.1.2)","categories":["other"],"row_index":91,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables External diameter of stranded cables (calculated) LV 122:2015-05 (p. 11.1.2) LV 122:2016-02 (p. 11.2.2) VW 75205:2019-11 (p. 11.1.2) VW 75205:2023-05 (p. 11.1.2) VW 75205:2024-04 (p. 11.2.3) MBN LV 122:2017-06 (p. 11.2.2) MBN 50122:2023-07 (p. 13.2.3) GS 95007-1-5:2015-07 (p. 11.1.2)","search_zh":"电缆 LV 122:2015-05 (p. 11.1.2) LV 122:2016-02 (p. 11.2.2) VW 75205:2019-11 (p. 11.1.2) VW 75205:2023-05 (p. 11.1.2) VW 75205:2024-04 (p. 11.2.3) MBN LV 122:2017-06 (p. 11.2.2) MBN 50122:2023-07 (p. 13.2.3) GS 95007-1-5:2015-07 (p. 11.1.2)","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ef4","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Długość skrętu, Lay length","methodology_en":"Lay length","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Długość skrętu, Lay length","reference":"ISO 19642-2:2023 (p. 6.2.5) LV 122:2015-05 (p. 11.1.3) LV 122:2016-02 (p. 11.2.3) VW 75205:2019-11 (p. 11.1.3) VW 75205:2023-05 (p. 11.1.3) VW 75205:2024-04 (p. 11.2.4) MBN LV 122:2017-06 (p. 11.2.3) MBN 50122:2023-07 (p. 13.2.4) GS 95007-1-5:2015-07 (p. 11.1.3)","norm_bases":["ISO 19642-2:2023 (p. 6.2.5) LV 122:2015-05 (p. 11.1.3) LV 122:2016-02 (p. 11.2.3) VW 75205:2019-11 (p. 11.1.3) VW 75205:2023-05 (p. 11.1.3) VW 75205:2024-04 (p. 11.2.4) MBN LV 122:2017-06 (p. 11.2.3) MBN 50122:2023-07 (p. 13.2.4) GS 95007-1-5:2015-07 (p. 11.1.3)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Długość skrętu, Lay length ISO 19642-2:2023 (p. 6.2.5) LV 122:2015-05 (p. 11.1.3) LV 122:2016-02 (p. 11.2.3) VW 75205:2019-11 (p. 11.1.3) VW 75205:2023-05 (p. 11.1.3) VW 75205:2024-04 (p. 11.2.4) MBN LV 122:2017-06 (p. 11.2.3) MBN 50122:2023-07 (p. 13.2.4) GS 95007-1-5:2015-07 (p. 11.1.3) Kable, Cables Dlugosc skretu, Lay length ISO 19642-2:2023 (p. 6.2.5) LV 122:2015-05 (p. 11.1.3) LV 122:2016-02 (p. 11.2.3) VW 75205:2019-11 (p. 11.1.3) VW 75205:2023-05 (p. 11.1.3) VW 75205:2024-04 (p. 11.2.4) MBN LV 122:2017-06 (p. 11.2.3) MBN 50122:2023-07 (p. 13.2.4) GS 95007-1-5:2015-07 (p. 11.1.3)","categories":["other"],"row_index":92,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Lay length ISO 19642-2:2023 (p. 6.2.5) LV 122:2015-05 (p. 11.1.3) LV 122:2016-02 (p. 11.2.3) VW 75205:2019-11 (p. 11.1.3) VW 75205:2023-05 (p. 11.1.3) VW 75205:2024-04 (p. 11.2.4) MBN LV 122:2017-06 (p. 11.2.3) MBN 50122:2023-07 (p. 13.2.4) GS 95007-1-5:2015-07 (p. 11.1.3)","search_zh":"电缆 ISO 19642-2:2023 (p. 6.2.5) LV 122:2015-05 (p. 11.1.3) LV 122:2016-02 (p. 11.2.3) VW 75205:2019-11 (p. 11.1.3) VW 75205:2023-05 (p. 11.1.3) VW 75205:2024-04 (p. 11.2.4) MBN LV 122:2017-06 (p. 11.2.3) MBN 50122:2023-07 (p. 13.2.4) GS 95007-1-5:2015-07 (p. 11.1.3)","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ef5","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Trwałość oznaczeń kabli","methodology_en":"Durability of cable markings","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Trwałość oznaczeń kabli","reference":"ISO 19642-2:2019-01 (p. 5.4.12; 6.4.11) | ISO 19642-2:2023 (p. 5.5.12; 6.5.11) | ISO 19642-3:2019-01 (p. 5.5.12) | ISO 19642-4:2019-01 (p. 5.5.12) | ISO 19642-5:2019-01 (p. 5.5.12) | ISO 19642-6:2019-01 (p. 5.5.12) | ISO 19642-7:2019-01 (p. 6.5.11) | ISO 19642-8:2019-01 (p. 6.5.11) | ISO 19642-9:2019-01 (p. 6.5.11) | ISO 19642-10:2019-01 (p. 6.5.11) | ISO 14572:2011-10 (p. 5.18) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.18) | ISO 6722-2:2013-12-01 (p. 5.18) LV 112-1:2013-04 (p. 9.6.11) LV 112-1:2014-04 (p. 9.6.11) LV 112-2:2007-11 (p. 8.7.10) LV 112-2:2013-04 (p. 9.6.11) LV 212-1:2015-01 (p. 9.6.10) LV 212-2:2015-01 (p. 9.6.10) LV 216-1:2015-07 (p. 9.6.11) LV 216-2:2017-02 (p. 9.6.10) VW 60306-1:2018-09-01 (p. 9.6.11) VW 60306-1:2021-10 (p. 9.7.11) VW 60306-2:2013-04 (p. 9.6.11) VW 60306-2:2021-11 (p. 9.7.11) VW 60306-4:2021-12 (p. 9.7.11) VW 75209-1:2015-01 (p. 9.6.10) VW 75209-1:2021-12 (p. 9.7.9) VW 75209-2:2015-01 (p. 9.6.10) VW 75209-2:2021-12 (p. 9.7.9) VW 75210-1:2023-06 (p. 9.7.11) VW 75210-1:2024-08 (p. 9.7.11) VW 75210-2:2023-06 (p. 9.7.10) MBN LV 112-1:2016-03 (p. 9.6.11) MBN 50112-1:2023-06 (p. 12.6.11) MBN LV 112-2:2012-01 (p. 8.7.10) MBN 50112-2: 2023-05 (p. 12.7.10) Scope of accreditation No. AB 1776","norm_bases":["ISO 19642-2:2019-01 (p. 5.4.12; 6.4.11)","ISO 19642-2:2023 (p. 5.5.12; 6.5.11)","ISO 19642-3:2019-01 (p. 5.5.12)","ISO 19642-4:2019-01 (p. 5.5.12)","ISO 19642-5:2019-01 (p. 5.5.12)","ISO 19642-6:2019-01 (p. 5.5.12)","ISO 19642-7:2019-01 (p. 6.5.11)","ISO 19642-8:2019-01 (p. 6.5.11)","ISO 19642-9:2019-01 (p. 6.5.11)","ISO 19642-10:2019-01 (p. 6.5.11)","ISO 14572:2011-10 (p. 5.18)","ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.18)","ISO 6722-2:2013-12-01 (p. 5.18) LV 112-1:2013-04 (p. 9.6.11) LV 112-1:2014-04 (p. 9.6.11) LV 112-2:2007-11 (p. 8.7.10) LV 112-2:2013-04 (p. 9.6.11) LV 212-1:2015-01 (p. 9.6.10) LV 212-2:2015-01 (p. 9.6.10) LV 216-1:2015-07 (p. 9.6.11) LV 216-2:2017-02 (p. 9.6.10) VW 60306-1:2018-09-01 (p. 9.6.11) VW 60306-1:2021-10 (p. 9.7.11) VW 60306-2:2013-04 (p. 9.6.11) VW 60306-2:2021-11 (p. 9.7.11) VW 60306-4:2021-12 (p. 9.7.11) VW 75209-1:2015-01 (p. 9.6.10) VW 75209-1:2021-12 (p. 9.7.9) VW 75209-2:2015-01 (p. 9.6.10) VW 75209-2:2021-12 (p. 9.7.9) VW 75210-1:2023-06 (p. 9.7.11) VW 75210-1:2024-08 (p. 9.7.11) VW 75210-2:2023-06 (p. 9.7.10) MBN LV 112-1:2016-03 (p. 9.6.11) MBN 50112-1:2023-06 (p. 12.6.11) MBN LV 112-2:2012-01 (p. 8.7.10) MBN 50112-2: 2023-05 (p. 12.7.10) Scope of accreditation No. AB 1776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Trwałość oznaczeń kabli ISO 19642-2:2019-01 (p. 5.4.12; 6.4.11) | ISO 19642-2:2023 (p. 5.5.12; 6.5.11) | ISO 19642-3:2019-01 (p. 5.5.12) | ISO 19642-4:2019-01 (p. 5.5.12) | ISO 19642-5:2019-01 (p. 5.5.12) | ISO 19642-6:2019-01 (p. 5.5.12) | ISO 19642-7:2019-01 (p. 6.5.11) | ISO 19642-8:2019-01 (p. 6.5.11) | ISO 19642-9:2019-01 (p. 6.5.11) | ISO 19642-10:2019-01 (p. 6.5.11) | ISO 14572:2011-10 (p. 5.18) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.18) | ISO 6722-2:2013-12-01 (p. 5.18) LV 112-1:2013-04 (p. 9.6.11) LV 112-1:2014-04 (p. 9.6.11) LV 112-2:2007-11 (p. 8.7.10) LV 112-2:2013-04 (p. 9.6.11) LV 212-1:2015-01 (p. 9.6.10) LV 212-2:2015-01 (p. 9.6.10) LV 216-1:2015-07 (p. 9.6.11) LV 216-2:2017-02 (p. 9.6.10) VW 60306-1:2018-09-01 (p. 9.6.11) VW 60306-1:2021-10 (p. 9.7.11) VW 60306-2:2013-04 (p. 9.6.11) VW 60306-2:2021-11 (p. 9.7.11) VW 60306-4:2021-12 (p. 9.7.11) VW 75209-1:2015-01 (p. 9.6.10) VW 75209-1:2021-12 (p. 9.7.9) VW 75209-2:2015-01 (p. 9.6.10) VW 75209-2:2021-12 (p. 9.7.9) VW 75210-1:2023-06 (p. 9.7.11) VW 75210-1:2024-08 (p. 9.7.11) VW 75210-2:2023-06 (p. 9.7.10) MBN LV 112-1:2016-03 (p. 9.6.11) MBN 50112-1:2023-06 (p. 12.6.11) MBN LV 112-2:2012-01 (p. 8.7.10) MBN 50112-2: 2023-05 (p. 12.7.10) Scope of accreditation No. AB 1776 Kable, Cables Trwalosc oznaczen kabli ISO 19642-2:2019-01 (p. 5.4.12; 6.4.11) | ISO 19642-2:2023 (p. 5.5.12; 6.5.11) | ISO 19642-3:2019-01 (p. 5.5.12) | ISO 19642-4:2019-01 (p. 5.5.12) | ISO 19642-5:2019-01 (p. 5.5.12) | ISO 19642-6:2019-01 (p. 5.5.12) | ISO 19642-7:2019-01 (p. 6.5.11) | ISO 19642-8:2019-01 (p. 6.5.11) | ISO 19642-9:2019-01 (p. 6.5.11) | ISO 19642-10:2019-01 (p. 6.5.11) | ISO 14572:2011-10 (p. 5.18) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.18) | ISO 6722-2:2013-12-01 (p. 5.18) LV 112-1:2013-04 (p. 9.6.11) LV 112-1:2014-04 (p. 9.6.11) LV 112-2:2007-11 (p. 8.7.10) LV 112-2:2013-04 (p. 9.6.11) LV 212-1:2015-01 (p. 9.6.10) LV 212-2:2015-01 (p. 9.6.10) LV 216-1:2015-07 (p. 9.6.11) LV 216-2:2017-02 (p. 9.6.10) VW 60306-1:2018-09-01 (p. 9.6.11) VW 60306-1:2021-10 (p. 9.7.11) VW 60306-2:2013-04 (p. 9.6.11) VW 60306-2:2021-11 (p. 9.7.11) VW 60306-4:2021-12 (p. 9.7.11) VW 75209-1:2015-01 (p. 9.6.10) VW 75209-1:2021-12 (p. 9.7.9) VW 75209-2:2015-01 (p. 9.6.10) VW 75209-2:2021-12 (p. 9.7.9) VW 75210-1:2023-06 (p. 9.7.11) VW 75210-1:2024-08 (p. 9.7.11) VW 75210-2:2023-06 (p. 9.7.10) MBN LV 112-1:2016-03 (p. 9.6.11) MBN 50112-1:2023-06 (p. 12.6.11) MBN LV 112-2:2012-01 (p. 8.7.10) MBN 50112-2: 2023-05 (p. 12.7.10) Scope of accreditation No. AB 1776","categories":["other"],"row_index":93,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Durability of cable markings ISO 19642-2:2019-01 (p. 5.4.12; 6.4.11) | ISO 19642-2:2023 (p. 5.5.12; 6.5.11) | ISO 19642-3:2019-01 (p. 5.5.12) | ISO 19642-4:2019-01 (p. 5.5.12) | ISO 19642-5:2019-01 (p. 5.5.12) | ISO 19642-6:2019-01 (p. 5.5.12) | ISO 19642-7:2019-01 (p. 6.5.11) | ISO 19642-8:2019-01 (p. 6.5.11) | ISO 19642-9:2019-01 (p. 6.5.11) | ISO 19642-10:2019-01 (p. 6.5.11) | ISO 14572:2011-10 (p. 5.18) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.18) | ISO 6722-2:2013-12-01 (p. 5.18) LV 112-1:2013-04 (p. 9.6.11) LV 112-1:2014-04 (p. 9.6.11) LV 112-2:2007-11 (p. 8.7.10) LV 112-2:2013-04 (p. 9.6.11) LV 212-1:2015-01 (p. 9.6.10) LV 212-2:2015-01 (p. 9.6.10) LV 216-1:2015-07 (p. 9.6.11) LV 216-2:2017-02 (p. 9.6.10) VW 60306-1:2018-09-01 (p. 9.6.11) VW 60306-1:2021-10 (p. 9.7.11) VW 60306-2:2013-04 (p. 9.6.11) VW 60306-2:2021-11 (p. 9.7.11) VW 60306-4:2021-12 (p. 9.7.11) VW 75209-1:2015-01 (p. 9.6.10) VW 75209-1:2021-12 (p. 9.7.9) VW 75209-2:2015-01 (p. 9.6.10) VW 75209-2:2021-12 (p. 9.7.9) VW 75210-1:2023-06 (p. 9.7.11) VW 75210-1:2024-08 (p. 9.7.11) VW 75210-2:2023-06 (p. 9.7.10) MBN LV 112-1:2016-03 (p. 9.6.11) MBN 50112-1:2023-06 (p. 12.6.11) MBN LV 112-2:2012-01 (p. 8.7.10) MBN 50112-2: 2023-05 (p. 12.7.10) Scope of accreditation No. AB 1776","search_zh":"电缆 ISO 19642-2:2019-01 (p. 5.4.12; 6.4.11) | ISO 19642-2:2023 (p. 5.5.12; 6.5.11) | ISO 19642-3:2019-01 (p. 5.5.12) | ISO 19642-4:2019-01 (p. 5.5.12) | ISO 19642-5:2019-01 (p. 5.5.12) | ISO 19642-6:2019-01 (p. 5.5.12) | ISO 19642-7:2019-01 (p. 6.5.11) | ISO 19642-8:2019-01 (p. 6.5.11) | ISO 19642-9:2019-01 (p. 6.5.11) | ISO 19642-10:2019-01 (p. 6.5.11) | ISO 14572:2011-10 (p. 5.18) | ISO 6722-1:2011-10-15; corr.1:2012-09-15 (p. 5.18) | ISO 6722-2:2013-12-01 (p. 5.18) LV 112-1:2013-04 (p. 9.6.11) LV 112-1:2014-04 (p. 9.6.11) LV 112-2:2007-11 (p. 8.7.10) LV 112-2:2013-04 (p. 9.6.11) LV 212-1:2015-01 (p. 9.6.10) LV 212-2:2015-01 (p. 9.6.10) LV 216-1:2015-07 (p. 9.6.11) LV 216-2:2017-02 (p. 9.6.10) VW 60306-1:2018-09-01 (p. 9.6.11) VW 60306-1:2021-10 (p. 9.7.11) VW 60306-2:2013-04 (p. 9.6.11) VW 60306-2:2021-11 (p. 9.7.11) VW 60306-4:2021-12 (p. 9.7.11) VW 75209-1:2015-01 (p. 9.6.10) VW 75209-1:2021-12 (p. 9.7.9) VW 75209-2:2015-01 (p. 9.6.10) VW 75209-2:2021-12 (p. 9.7.9) VW 75210-1:2023-06 (p. 9.7.11) VW 75210-1:2024-08 (p. 9.7.11) VW 75210-2:2023-06 (p. 9.7.10) MBN LV 112-1:2016-03 (p. 9.6.11) MBN 50112-1:2023-06 (p. 12.6.11) MBN LV 112-2:2012-01 (p. 8.7.10) MBN 50112-2: 2023-05 (p. 12.7.10) Scope of accreditation No. AB 1776","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ef6","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"","methodology_en":null,"parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"","reference":"MBN 50216-1:2023-07 (p. 12.7.10) MBN LV 212-1:2017-08 (p. 9.6.10) MBN 50212-1:2023-04 (p. 12.7.10) MBN LV 216-2:2017-07 (p. 9.6.10) MBN 50112-4:2024-06 (p. 12.6.11) GS 95007-1-1:2013-05 (p. 9.6.11) GS 95007-1-2:2013-05 (p. 9.6.11) GS 95007-3-1:2015-08 (p. 9.6.10) GS 95007-3-2:2015-09 (p. 9.6.10) GS 95007-6-1:2016-03 (p. 9.6.11) GS 95007-6-2:2017-04 (p. 9.6.10)","norm_bases":["MBN 50216-1:2023-07 (p. 12.7.10) MBN LV 212-1:2017-08 (p. 9.6.10) MBN 50212-1:2023-04 (p. 12.7.10) MBN LV 216-2:2017-07 (p. 9.6.10) MBN 50112-4:2024-06 (p. 12.6.11) GS 95007-1-1:2013-05 (p. 9.6.11) GS 95007-1-2:2013-05 (p. 9.6.11) GS 95007-3-1:2015-08 (p. 9.6.10) GS 95007-3-2:2015-09 (p. 9.6.10) GS 95007-6-1:2016-03 (p. 9.6.11) GS 95007-6-2:2017-04 (p. 9.6.10)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables MBN 50216-1:2023-07 (p. 12.7.10) MBN LV 212-1:2017-08 (p. 9.6.10) MBN 50212-1:2023-04 (p. 12.7.10) MBN LV 216-2:2017-07 (p. 9.6.10) MBN 50112-4:2024-06 (p. 12.6.11) GS 95007-1-1:2013-05 (p. 9.6.11) GS 95007-1-2:2013-05 (p. 9.6.11) GS 95007-3-1:2015-08 (p. 9.6.10) GS 95007-3-2:2015-09 (p. 9.6.10) GS 95007-6-1:2016-03 (p. 9.6.11) GS 95007-6-2:2017-04 (p. 9.6.10) Kable, Cables MBN 50216-1:2023-07 (p. 12.7.10) MBN LV 212-1:2017-08 (p. 9.6.10) MBN 50212-1:2023-04 (p. 12.7.10) MBN LV 216-2:2017-07 (p. 9.6.10) MBN 50112-4:2024-06 (p. 12.6.11) GS 95007-1-1:2013-05 (p. 9.6.11) GS 95007-1-2:2013-05 (p. 9.6.11) GS 95007-3-1:2015-08 (p. 9.6.10) GS 95007-3-2:2015-09 (p. 9.6.10) GS 95007-6-1:2016-03 (p. 9.6.11) GS 95007-6-2:2017-04 (p. 9.6.10)","categories":["other"],"row_index":94,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables MBN 50216-1:2023-07 (p. 12.7.10) MBN LV 212-1:2017-08 (p. 9.6.10) MBN 50212-1:2023-04 (p. 12.7.10) MBN LV 216-2:2017-07 (p. 9.6.10) MBN 50112-4:2024-06 (p. 12.6.11) GS 95007-1-1:2013-05 (p. 9.6.11) GS 95007-1-2:2013-05 (p. 9.6.11) GS 95007-3-1:2015-08 (p. 9.6.10) GS 95007-3-2:2015-09 (p. 9.6.10) GS 95007-6-1:2016-03 (p. 9.6.11) GS 95007-6-2:2017-04 (p. 9.6.10)","search_zh":"电缆 MBN 50216-1:2023-07 (p. 12.7.10) MBN LV 212-1:2017-08 (p. 9.6.10) MBN 50212-1:2023-04 (p. 12.7.10) MBN LV 216-2:2017-07 (p. 9.6.10) MBN 50112-4:2024-06 (p. 12.6.11) GS 95007-1-1:2013-05 (p. 9.6.11) GS 95007-1-2:2013-05 (p. 9.6.11) GS 95007-3-1:2015-08 (p. 9.6.10) GS 95007-3-2:2015-09 (p. 9.6.10) GS 95007-6-1:2016-03 (p. 9.6.11) GS 95007-6-2:2017-04 (p. 9.6.10)","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ef7","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Długość nieskręconych końców kabli","methodology_en":"Length of untwisted cable ends","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Długość nieskręconych końców kabli","reference":"LV 122:2015-05 (p. 11.1.7) LV 122:2016-02 (p. 11.2.7) VW 75205:2019-11 (p. 11.1.5) VW 75205:2023-05 (p. 11.1.5) VW 75205:2024-04 (p. 11.2.6) MBN LV 122:2017-06 (p. 11.2.7) MBN 50122:2023-07 (p. 13.2.8) GS 95007-1-5:2015-07 (p. 11.1.7)","norm_bases":["LV 122:2015-05 (p. 11.1.7) LV 122:2016-02 (p. 11.2.7) VW 75205:2019-11 (p. 11.1.5) VW 75205:2023-05 (p. 11.1.5) VW 75205:2024-04 (p. 11.2.6) MBN LV 122:2017-06 (p. 11.2.7) MBN 50122:2023-07 (p. 13.2.8) GS 95007-1-5:2015-07 (p. 11.1.7)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Długość nieskręconych końców kabli LV 122:2015-05 (p. 11.1.7) LV 122:2016-02 (p. 11.2.7) VW 75205:2019-11 (p. 11.1.5) VW 75205:2023-05 (p. 11.1.5) VW 75205:2024-04 (p. 11.2.6) MBN LV 122:2017-06 (p. 11.2.7) MBN 50122:2023-07 (p. 13.2.8) GS 95007-1-5:2015-07 (p. 11.1.7) Kable, Cables Dlugosc nieskreconych koncow kabli LV 122:2015-05 (p. 11.1.7) LV 122:2016-02 (p. 11.2.7) VW 75205:2019-11 (p. 11.1.5) VW 75205:2023-05 (p. 11.1.5) VW 75205:2024-04 (p. 11.2.6) MBN LV 122:2017-06 (p. 11.2.7) MBN 50122:2023-07 (p. 13.2.8) GS 95007-1-5:2015-07 (p. 11.1.7)","categories":["other"],"row_index":95,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Length of untwisted cable ends LV 122:2015-05 (p. 11.1.7) LV 122:2016-02 (p. 11.2.7) VW 75205:2019-11 (p. 11.1.5) VW 75205:2023-05 (p. 11.1.5) VW 75205:2024-04 (p. 11.2.6) MBN LV 122:2017-06 (p. 11.2.7) MBN 50122:2023-07 (p. 13.2.8) GS 95007-1-5:2015-07 (p. 11.1.7)","search_zh":"电缆 LV 122:2015-05 (p. 11.1.7) LV 122:2016-02 (p. 11.2.7) VW 75205:2019-11 (p. 11.1.5) VW 75205:2023-05 (p. 11.1.5) VW 75205:2024-04 (p. 11.2.6) MBN LV 122:2017-06 (p. 11.2.7) MBN 50122:2023-07 (p. 13.2.8) GS 95007-1-5:2015-07 (p. 11.1.7)","test_object_zh":"电缆"},{"_id":"6a5dc9a9f1c10c8ce8259ef8","lab_id":"69ad52a3de79e566650fb96d","country":"PL","accr_number":"AB 1776","accr_body":"PCA","test_object":"Kable, Cables","test_object_en":"Cables","methodology":"Stabilność termiczna PVC","methodology_en":"Thermal stability of PVC","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stabilność termiczna PVC","reference":"IEC 60811-405:2012 LV 112-1:2013-04 (p. 9.2.5) LV 112-1:2014-04 (p. 9.2.5) LV 112-2:2007-11 (p. 8.3) LV 112-2:2013-04 (p. 9.2) LV 212-1:2015-01 (p. 9.2.5) LV 212-2:2015-01 (p. 9.2.5) LV 216-1:2015-07 (p. 9.2.5) LV 216-2:2017-02 (p. 9.2.5) VW 60306-1:2018-09 (p. 9.2.2) VW 60306-1:2021-10 (p. 9.3.3) VW 60306-2:2013-04 (p. 9.2) VW 60306-2:2021-11 (p. 9.3.3) VW 60306-4:2021-12 (p. 9.3.3) VW 75209-1:2015-01 (p. 9.2.5) VW 75209-1:2021-12 (p. 9.3.3) VW 75209-2:2015-01 (p. 9.2.5) VW 75209-2:2021-12 (p. 9.3.3) VW 75210-1:2023-06 (p. 9.3.3) VW 75210-1:2024-08 (p. 9.3.3) VW 75210-2:2023-06 (p. 9.3.3) MBN LV 112-1:2016-03 (p. 9.2.5) MBN 50112-1:2023-06 (p. 12.2.6) MBN LV 112-2:2012-01 (p. 8.3) MBN 50112-2: 2023-05 (p. 12.3) MBN 50216-1:2023-07 (p. 12.3.6) MBN LV 212-1:2017-08 (p. 9.2.5) MBN 50212-1:2023-04 (p. 12.3.6) MBN LV 216-2:2017-07 (p. 9.2.5) MBN 50112-4:2024-06 (p. 12.2.6) GS 95007-1-1:2013-05 (p. 9.2.5) GS 95007-1-2:2013-05 (p. 9.2) GS 95007-3-1:2015-08 (p. 9.2.5) GS 95007-3-2:2015-09 (p. 9.2.5) GS 95007-6-1:2016-03 (p. 9.2.5) GS 95007-6-2:2017-04 (p. 9.2.5)","norm_bases":["IEC 60811-405:2012 LV 112-1:2013-04 (p. 9.2.5) LV 112-1:2014-04 (p. 9.2.5) LV 112-2:2007-11 (p. 8.3) LV 112-2:2013-04 (p. 9.2) LV 212-1:2015-01 (p. 9.2.5) LV 212-2:2015-01 (p. 9.2.5) LV 216-1:2015-07 (p. 9.2.5) LV 216-2:2017-02 (p. 9.2.5) VW 60306-1:2018-09 (p. 9.2.2) VW 60306-1:2021-10 (p. 9.3.3) VW 60306-2:2013-04 (p. 9.2) VW 60306-2:2021-11 (p. 9.3.3) VW 60306-4:2021-12 (p. 9.3.3) VW 75209-1:2015-01 (p. 9.2.5) VW 75209-1:2021-12 (p. 9.3.3) VW 75209-2:2015-01 (p. 9.2.5) VW 75209-2:2021-12 (p. 9.3.3) VW 75210-1:2023-06 (p. 9.3.3) VW 75210-1:2024-08 (p. 9.3.3) VW 75210-2:2023-06 (p. 9.3.3) MBN LV 112-1:2016-03 (p. 9.2.5) MBN 50112-1:2023-06 (p. 12.2.6) MBN LV 112-2:2012-01 (p. 8.3) MBN 50112-2: 2023-05 (p. 12.3) MBN 50216-1:2023-07 (p. 12.3.6) MBN LV 212-1:2017-08 (p. 9.2.5) MBN 50212-1:2023-04 (p. 12.3.6) MBN LV 216-2:2017-07 (p. 9.2.5) MBN 50112-4:2024-06 (p. 12.2.6) GS 95007-1-1:2013-05 (p. 9.2.5) GS 95007-1-2:2013-05 (p. 9.2) GS 95007-3-1:2015-08 (p. 9.2.5) GS 95007-3-2:2015-09 (p. 9.2.5) GS 95007-6-1:2016-03 (p. 9.2.5) GS 95007-6-2:2017-04 (p. 9.2.5)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kable, Cables Stabilność termiczna PVC IEC 60811-405:2012 LV 112-1:2013-04 (p. 9.2.5) LV 112-1:2014-04 (p. 9.2.5) LV 112-2:2007-11 (p. 8.3) LV 112-2:2013-04 (p. 9.2) LV 212-1:2015-01 (p. 9.2.5) LV 212-2:2015-01 (p. 9.2.5) LV 216-1:2015-07 (p. 9.2.5) LV 216-2:2017-02 (p. 9.2.5) VW 60306-1:2018-09 (p. 9.2.2) VW 60306-1:2021-10 (p. 9.3.3) VW 60306-2:2013-04 (p. 9.2) VW 60306-2:2021-11 (p. 9.3.3) VW 60306-4:2021-12 (p. 9.3.3) VW 75209-1:2015-01 (p. 9.2.5) VW 75209-1:2021-12 (p. 9.3.3) VW 75209-2:2015-01 (p. 9.2.5) VW 75209-2:2021-12 (p. 9.3.3) VW 75210-1:2023-06 (p. 9.3.3) VW 75210-1:2024-08 (p. 9.3.3) VW 75210-2:2023-06 (p. 9.3.3) MBN LV 112-1:2016-03 (p. 9.2.5) MBN 50112-1:2023-06 (p. 12.2.6) MBN LV 112-2:2012-01 (p. 8.3) MBN 50112-2: 2023-05 (p. 12.3) MBN 50216-1:2023-07 (p. 12.3.6) MBN LV 212-1:2017-08 (p. 9.2.5) MBN 50212-1:2023-04 (p. 12.3.6) MBN LV 216-2:2017-07 (p. 9.2.5) MBN 50112-4:2024-06 (p. 12.2.6) GS 95007-1-1:2013-05 (p. 9.2.5) GS 95007-1-2:2013-05 (p. 9.2) GS 95007-3-1:2015-08 (p. 9.2.5) GS 95007-3-2:2015-09 (p. 9.2.5) GS 95007-6-1:2016-03 (p. 9.2.5) GS 95007-6-2:2017-04 (p. 9.2.5) Kable, Cables Stabilnosc termiczna PVC IEC 60811-405:2012 LV 112-1:2013-04 (p. 9.2.5) LV 112-1:2014-04 (p. 9.2.5) LV 112-2:2007-11 (p. 8.3) LV 112-2:2013-04 (p. 9.2) LV 212-1:2015-01 (p. 9.2.5) LV 212-2:2015-01 (p. 9.2.5) LV 216-1:2015-07 (p. 9.2.5) LV 216-2:2017-02 (p. 9.2.5) VW 60306-1:2018-09 (p. 9.2.2) VW 60306-1:2021-10 (p. 9.3.3) VW 60306-2:2013-04 (p. 9.2) VW 60306-2:2021-11 (p. 9.3.3) VW 60306-4:2021-12 (p. 9.3.3) VW 75209-1:2015-01 (p. 9.2.5) VW 75209-1:2021-12 (p. 9.3.3) VW 75209-2:2015-01 (p. 9.2.5) VW 75209-2:2021-12 (p. 9.3.3) VW 75210-1:2023-06 (p. 9.3.3) VW 75210-1:2024-08 (p. 9.3.3) VW 75210-2:2023-06 (p. 9.3.3) MBN LV 112-1:2016-03 (p. 9.2.5) MBN 50112-1:2023-06 (p. 12.2.6) MBN LV 112-2:2012-01 (p. 8.3) MBN 50112-2: 2023-05 (p. 12.3) MBN 50216-1:2023-07 (p. 12.3.6) MBN LV 212-1:2017-08 (p. 9.2.5) MBN 50212-1:2023-04 (p. 12.3.6) MBN LV 216-2:2017-07 (p. 9.2.5) MBN 50112-4:2024-06 (p. 12.2.6) GS 95007-1-1:2013-05 (p. 9.2.5) GS 95007-1-2:2013-05 (p. 9.2) GS 95007-3-1:2015-08 (p. 9.2.5) GS 95007-3-2:2015-09 (p. 9.2.5) GS 95007-6-1:2016-03 (p. 9.2.5) GS 95007-6-2:2017-04 (p. 9.2.5)","categories":["other"],"row_index":96,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cables Thermal stability of PVC IEC 60811-405:2012 LV 112-1:2013-04 (p. 9.2.5) LV 112-1:2014-04 (p. 9.2.5) LV 112-2:2007-11 (p. 8.3) LV 112-2:2013-04 (p. 9.2) LV 212-1:2015-01 (p. 9.2.5) LV 212-2:2015-01 (p. 9.2.5) LV 216-1:2015-07 (p. 9.2.5) LV 216-2:2017-02 (p. 9.2.5) VW 60306-1:2018-09 (p. 9.2.2) VW 60306-1:2021-10 (p. 9.3.3) VW 60306-2:2013-04 (p. 9.2) VW 60306-2:2021-11 (p. 9.3.3) VW 60306-4:2021-12 (p. 9.3.3) VW 75209-1:2015-01 (p. 9.2.5) VW 75209-1:2021-12 (p. 9.3.3) VW 75209-2:2015-01 (p. 9.2.5) VW 75209-2:2021-12 (p. 9.3.3) VW 75210-1:2023-06 (p. 9.3.3) VW 75210-1:2024-08 (p. 9.3.3) VW 75210-2:2023-06 (p. 9.3.3) MBN LV 112-1:2016-03 (p. 9.2.5) MBN 50112-1:2023-06 (p. 12.2.6) MBN LV 112-2:2012-01 (p. 8.3) MBN 50112-2: 2023-05 (p. 12.3) MBN 50216-1:2023-07 (p. 12.3.6) MBN LV 212-1:2017-08 (p. 9.2.5) MBN 50212-1:2023-04 (p. 12.3.6) MBN LV 216-2:2017-07 (p. 9.2.5) MBN 50112-4:2024-06 (p. 12.2.6) GS 95007-1-1:2013-05 (p. 9.2.5) GS 95007-1-2:2013-05 (p. 9.2) GS 95007-3-1:2015-08 (p. 9.2.5) GS 95007-3-2:2015-09 (p. 9.2.5) GS 95007-6-1:2016-03 (p. 9.2.5) GS 95007-6-2:2017-04 (p. 9.2.5)","search_zh":"电缆 IEC 60811-405:2012 LV 112-1:2013-04 (p. 9.2.5) LV 112-1:2014-04 (p. 9.2.5) LV 112-2:2007-11 (p. 8.3) LV 112-2:2013-04 (p. 9.2) LV 212-1:2015-01 (p. 9.2.5) LV 212-2:2015-01 (p. 9.2.5) LV 216-1:2015-07 (p. 9.2.5) LV 216-2:2017-02 (p. 9.2.5) VW 60306-1:2018-09 (p. 9.2.2) VW 60306-1:2021-10 (p. 9.3.3) VW 60306-2:2013-04 (p. 9.2) VW 60306-2:2021-11 (p. 9.3.3) VW 60306-4:2021-12 (p. 9.3.3) VW 75209-1:2015-01 (p. 9.2.5) VW 75209-1:2021-12 (p. 9.3.3) VW 75209-2:2015-01 (p. 9.2.5) VW 75209-2:2021-12 (p. 9.3.3) VW 75210-1:2023-06 (p. 9.3.3) VW 75210-1:2024-08 (p. 9.3.3) VW 75210-2:2023-06 (p. 9.3.3) MBN LV 112-1:2016-03 (p. 9.2.5) MBN 50112-1:2023-06 (p. 12.2.6) MBN LV 112-2:2012-01 (p. 8.3) MBN 50112-2: 2023-05 (p. 12.3) MBN 50216-1:2023-07 (p. 12.3.6) MBN LV 212-1:2017-08 (p. 9.2.5) MBN 50212-1:2023-04 (p. 12.3.6) MBN LV 216-2:2017-07 (p. 9.2.5) MBN 50112-4:2024-06 (p. 12.2.6) GS 95007-1-1:2013-05 (p. 9.2.5) GS 95007-1-2:2013-05 (p. 9.2) GS 95007-3-1:2015-08 (p. 9.2.5) GS 95007-3-2:2015-09 (p. 9.2.5) GS 95007-6-1:2016-03 (p. 9.2.5) GS 95007-6-2:2017-04 (p. 9.2.5)","test_object_zh":"电缆"}],"has_pdf":true}