{"lab":{"_id":"69ad52a3de79e566650fb159","accr_number":"AB 177","country":"PL","accr_body":"PCA","address":"ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W SZCZECINIE, ul. Wały Chrobrego 4","categories":["water","materials"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":85,"name":"GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_177.pdf"],"scope_summary":"","search_text":"główny inspektorat ochrony środowiska ul. chmielna 132/134, 00-805 warszawa, centralne laboratorium badawcze, oddział w szczecinie, ul. wały chrobrego 4 water other pharma electronics environment metrology petro materials food","status":"active","updated_at":"2026-03-08T14:50:53.884Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T14:59:14.634Z","location":{"type":"Point","coordinates":[21.0122,52.2297]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20177,podmiot.html","needs_review":true,"review_reason":"e-mail niepewny (low) — zweryfikuj","fields_of_testing":[{"codes":"C/28/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków","en":"Chemical tests and sampling of water, sewage"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas, pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise, electromagnetic field)"},{"codes":"N/28/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków","en":"Tests of physical properties and sampling of water, sewage"}],"issue":{"no":"28","date":"06.05.2026"},"parse_date":"2026-08-17T14:59:14.634Z","parse_source":"agent-claude-code","map_coord":[52.227738,20.992749],"map_geo":"nominatim-street","lab_locations":[{"name":"ODDZIAŁ W SZCZECINIE","address":"ul. Wały Chrobrego 4","city":null,"postal":null},{"name":"Pracownia Terenowa","address":"ul. Wały Chrobrego 4, 70-502 Szczecin","city":"Szczecin","postal":"70-502"},{"name":"Pracownia w Szczecinie","address":"ul. Wały Chrobrego 4, 70-502 Szczecin","city":"Szczecin","postal":"70-502"},{"name":"Pracownia w Koszalinie","address":"ul. Zgoda 23, 75-553 Koszalin","city":"Koszalin","postal":"75-553"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/e02d24d47d96ad707655de3ce5c8c1e2/AB%20177.pdf","has_en":true,"category_counts":{"water":81,"materials":7,"environment":4,"petro":1},"category_scores":{"water":70.55,"materials":0.53,"environment":0.17,"petro":0.01},"has_zh":true},"methods":[{"_id":"6a8321c2884ede9a1b2c4d37","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 z wyłączeniem p.9.2 i 9.4 | PN-ISO 5667-9:2005 | PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3","norm_bases":["PN-ISO 5667-4:2017-10","PN-EN ISO 5667-6:2016-12 z wyłączeniem p.9.2 i 9.4","PN-ISO 5667-9:2005","PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 z wyłączeniem p.9.2 i 9.4 | PN-ISO 5667-9:2005 | PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3 Woda Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 z wylaczeniem p.9.2 i 9.4 | PN-ISO 5667-9:2005 | PN-ISO 5667-11:2017-10 z wylaczeniem p. 5.2, 6.1.2, 6.2, 6.3","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 z wyłączeniem p.9.2 i 9.4 | PN-ISO 5667-9:2005 | PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3","test_object_en":"Water","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 z wyłączeniem p.9.2 i 9.4 | PN-ISO 5667-9:2005 | PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3","test_object_zh":"水"},{"_id":"6a8321c2884ede9a1b2c4d38","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (0 – 50,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura\nZakres (0 – 50,0) °C PN-77/C-04584 Woda Temperatura\nZakres (0 – 50,0) °C PN-77/C-04584","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(0 – 50,0) °C"}],"search_en":"Water Temperature Range PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0 – 50,0) °C"}],"search_zh":"水 温度 范围 PN-77/C-04584","test_object_zh":"水","methodology_zh":"温度"},{"_id":"6a8321c2884ede9a1b2c4d39","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5 – 20) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 – 20) mg/l O2\nMetoda optyczna","reference":"ISO 17289:2014","norm_bases":["ISO 17289:2014"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie tlenu rozpuszczonego\nZakres (0,5 – 20) mg/l O2\nMetoda optyczna ISO 17289:2014 Woda Stezenie tlenu rozpuszczonego\nZakres (0,5 – 20) mg/l O2\nMetoda optyczna ISO 17289:2014","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 20) mg/l O2"}],"search_en":"Water Dissolved oxygen concentration Optical method Range ISO 17289:2014","technique_en":"Optical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,5 – 20) mg/l O2"}],"search_zh":"水 溶解氧浓度 光学法 范围 ISO 17289:2014","technique_zh":"光学法","test_object_zh":"水","methodology_zh":"溶解氧浓度"},{"_id":"6a8321c2884ede9a1b2c4d3a","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5 – 20) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 – 20) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie tlenu rozpuszczonego\nZakres (0,5 – 20) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda Stezenie tlenu rozpuszczonego\nZakres (0,5 – 20) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 20) mg/l O2"}],"search_en":"Water Dissolved oxygen concentration Electrochemical method Range PN-EN ISO 5814:2013-04","technique_en":"Electrochemical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,5 – 20) mg/l O2"}],"search_zh":"水 溶解氧浓度 电化学法 范围 PN-EN ISO 5814:2013-04","technique_zh":"电化学法","test_object_zh":"水","methodology_zh":"溶解氧浓度"},{"_id":"6a8321c2884ede9a1b2c4d3b","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method PN-ISO 5667-10:2021-11","technique_en":"Manual and automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手工与自动法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"手工与自动法"},{"_id":"6a8321c2884ede9a1b2c4d3c","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (0 – 50,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura\nZakres (0 – 50,0) °C PN-77/C-04584 Scieki Temperatura\nZakres (0 – 50,0) °C PN-77/C-04584","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(0 – 50,0) °C"}],"search_en":"Wastewater Temperature Range PN-77/C-04584","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0 – 50,0) °C"}],"search_zh":"污水 温度 范围 PN-77/C-04584","test_object_zh":"污水","methodology_zh":"温度"},{"_id":"6a8321c2884ede9a1b2c4d3d","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10,0 – 13 000) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10,0 – 13 000) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres (10,0 – 13 000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres (10,0 – 13 000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10,0 – 13 000) µS/cm"}],"search_en":"Water, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10,0 – 13 000) µS/cm"}],"search_zh":"水、废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水"},{"_id":"6a8321c2884ede9a1b2c4d3e","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Water, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a8321c2884ede9a1b2c4d3f","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7 września 2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7 września 2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezpośrednia Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7 września 2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (24 – 135) dB\nMetoda pomiarowa bezposrednia Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 7 wrzesnia 2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(24 – 135) dB"}],"search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7 września 2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(24 – 135) dB"}],"search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7 września 2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a8321c2884ede9a1b2c4d40","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7 września 2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7 września 2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7 września 2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 7 wrzesnia 2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7 września 2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7 września 2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a8321c2884ede9a1b2c4d41","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 10 MHz do 60 GHz"},{"name":"Zakres","range":"(0,5 – 300) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 MHz do 60 GHz\nZakres (0,5 – 300) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 MHz do 60 GHz\nZakres (0,5 – 300) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 MHz do 60 GHz\nZakres (0,5 – 300) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range","range":"od 10 MHz do 60 GHz"},{"name":"Range","range":"(0,5 – 300) V/m"}],"search_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Electric field strength: Direct measurement method in the frequency range Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations: broadband measurements","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围","range":"od 10 MHz do 60 GHz"},{"name":"范围","range":"(0,5 – 300) V/m"}],"search_zh":"电场强度： 直接测量法 频率范围 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法"},{"_id":"6a8321c2884ede9a1b2c4d42","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 10 MHz do 60 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 MHz do 60 GHz\n(z obliczeń)","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 10 MHz do 60 GHz\n(z obliczeń) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 10 MHz do 60 GHz\n(z obliczen) Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 10 MHz do 60 GHz"},{"name":"(calculated)"}],"search_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Magnetic field strength: in the frequency range (calculated) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations: broadband measurements","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 10 MHz do 60 GHz"},{"name":"（计算得出）"}],"search_zh":"磁场强度： 频率范围 （计算得出） Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"},{"_id":"6a8321c2884ede9a1b2c4d43","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,001 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,001 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu azotynowego\nZakres (0,001 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda Stezenie azotu azotynowego\nZakres (0,001 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,001 – 10,0) mg/l"}],"search_en":"Water Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 10,0) mg/l"}],"search_zh":"水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a8321c2884ede9a1b2c4d44","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotynów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotynów (z obliczeń)","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotynów (z obliczeń) PN-EN 26777:1999 Woda Stezenie azotynow (z obliczen) PN-EN 26777:1999","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration (calculated)","search_en":"Water Nitrite concentration (calculated) PN-EN 26777:1999","test_object_en":"Water","search_zh":"水 亚硝酸盐浓度（由计算得出） PN-EN 26777:1999","test_object_zh":"水","methodology_zh":"亚硝酸盐浓度（由计算得出）"},{"_id":"6a8321c2884ede9a1b2c4d45","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(0,25 – 100) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (0,25 – 100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 11905-1:2001","norm_bases":["PN-EN ISO 11905-1:2001"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu ogólnego\nZakres (0,25 – 100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 11905-1:2001 Woda Stezenie azotu ogolnego\nZakres (0,25 – 100) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 11905-1:2001","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,25 – 100) mg/l"}],"search_en":"Water Total nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 11905-1:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(0,25 – 100) mg/l"}],"search_zh":"水 总氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 11905-1:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水"},{"_id":"6a8321c2884ede9a1b2c4d46","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie rozpuszczonych jonów","parameters":[{"name":"chlorki","range":"(1,0 – 1000) mg/l"},{"name":"azotany","range":"(0,50 – 300) mg/l"},{"name":"siarczany","range":"(1,0 – 1000) mg/l"},{"name":"fluorki","range":"(0,10 – 10) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie rozpuszczonych jonów\nZakres:\nchlorki (1,0 – 1000) mg/l\nazotany (0,50 – 300) mg/l\nsiarczany (1,0 – 1000) mg/l\nfluorki (0,10 – 10) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","norm_bases":["PN-EN ISO 10304-1:2009","PN-EN ISO 10304-1:2009/AC:2012"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie rozpuszczonych jonów\nZakres:\nchlorki (1,0 – 1000) mg/l\nazotany (0,50 – 300) mg/l\nsiarczany (1,0 – 1000) mg/l\nfluorki (0,10 – 10) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012 Woda Stezenie rozpuszczonych jonow\nZakres:\nchlorki (1,0 – 1000) mg/l\nazotany (0,50 – 300) mg/l\nsiarczany (1,0 – 1000) mg/l\nfluorki (0,10 – 10) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved ion concentration","parameters_en":[{"name":"chlorides","range":"(1,0 – 1000) mg/l"},{"name":"nitrates","range":"(0,50 – 300) mg/l"},{"name":"sulfates","range":"(1,0 – 1000) mg/l"},{"name":"fluorides","range":"(0,10 – 10) mg/l"}],"search_en":"Water Dissolved ion concentration Ion chromatography with conductometric detection (IC-CD) chlorides nitrates sulfates fluorides PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water","search_zh":"水 溶解性离子浓度 离子色谱-电导检测法（IC-CD） 氯化物 硝酸盐 硫酸盐 氟化物 PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水","parameters_zh":[{"name":"氯化物","range":"(1,0 – 1000) mg/l"},{"name":"硝酸盐","range":"(0,50 – 300) mg/l"},{"name":"硫酸盐","range":"(1,0 – 1000) mg/l"},{"name":"氟化物","range":"(0,10 – 10) mg/l"}],"methodology_zh":"溶解性离子浓度"},{"_id":"6a8321c2884ede9a1b2c4d47","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu azotanowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu azotanowego (z obliczeń)","reference":"PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","norm_bases":["PN-EN ISO 10304-1:2009","PN-EN ISO 10304-1:2009/AC:2012"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu azotanowego (z obliczeń) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012 Woda Stezenie azotu azotanowego (z obliczen) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration (calculated)","search_en":"Water Nitrate nitrogen concentration (calculated) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","test_object_en":"Water","search_zh":"水 硝酸盐氮浓度（由计算得出） PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","test_object_zh":"水","methodology_zh":"硝酸盐氮浓度（由计算得出）"},{"_id":"6a8321c2884ede9a1b2c4d48","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie rozpuszczonych jonów","parameters":[{"name":"potas","range":"(0,50 – 100) mg/l"},{"name":"sód","range":"(1,0 – 500) mg/l"},{"name":"magnez","range":"(1,0 – 100) mg/l"},{"name":"wapń","range":"(2,0 – 500) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie rozpuszczonych jonów\nZakres:\npotas (0,50 – 100) mg/l\nsód (1,0 – 500) mg/l\nmagnez (1,0 – 100) mg/l\nwapń (2,0 – 500) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 14911:2002","norm_bases":["PN-EN ISO 14911:2002"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie rozpuszczonych jonów\nZakres:\npotas (0,50 – 100) mg/l\nsód (1,0 – 500) mg/l\nmagnez (1,0 – 100) mg/l\nwapń (2,0 – 500) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 14911:2002 Woda Stezenie rozpuszczonych jonow\nZakres:\npotas (0,50 – 100) mg/l\nsod (1,0 – 500) mg/l\nmagnez (1,0 – 100) mg/l\nwapn (2,0 – 500) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 14911:2002","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved ion concentration","parameters_en":[{"name":"potassium","range":"(0,50 – 100) mg/l"},{"name":"sodium","range":"(1,0 – 500) mg/l"},{"name":"magnesium","range":"(1,0 – 100) mg/l"},{"name":"calcium","range":"(2,0 – 500) mg/l"}],"search_en":"Water Dissolved ion concentration Ion chromatography with conductometric detection (IC-CD) potassium sodium magnesium calcium PN-EN ISO 14911:2002","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water","search_zh":"水 溶解性离子浓度 离子色谱-电导检测法（IC-CD） 钾 钠 镁 钙 PN-EN ISO 14911:2002","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水","parameters_zh":[{"name":"钾","range":"(0,50 – 100) mg/l"},{"name":"钠","range":"(1,0 – 500) mg/l"},{"name":"镁","range":"(1,0 – 100) mg/l"},{"name":"钙","range":"(2,0 – 500) mg/l"}],"methodology_zh":"溶解性离子浓度"},{"_id":"6a8321c2884ede9a1b2c4d49","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie metali","parameters":[{"name":"bar","range":"(0,020 – 10) mg/l"},{"name":"bor","range":"(0,100 – 10) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie metali\nZakres:\nbar (0,020 – 10) mg/l\nbor (0,100 – 10) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie metali\nZakres:\nbar (0,020 – 10) mg/l\nbor (0,100 – 10) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda Stezenie metali\nZakres:\nbar (0,020 – 10) mg/l\nbor (0,100 – 10) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["materials","water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"barium","range":"(0,020 – 10) mg/l"},{"name":"boron","range":"(0,100 – 10) mg/l"}],"search_en":"Water Metal concentrations Inductively coupled plasma optical emission spectrometry (ICP-OES) barium boron PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water","methodology_zh":"金属浓度","search_zh":"水 金属浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 钡 硼 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水","parameters_zh":[{"name":"钡","range":"(0,020 – 10) mg/l"},{"name":"硼","range":"(0,100 – 10) mg/l"}]},{"_id":"6a8321c2884ede9a1b2c4d4a","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie metali","parameters":[{"name":"arsen","range":"(0,001 – 5) mg/l"},{"name":"selen","range":"(0,002 – 5) mg/l"},{"name":"kadm","range":"(0,000024 – 10) mg/l"},{"name":"ołów","range":"(0,00036 – 10) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie metali\nZakres:\narsen (0,001 – 5) mg/l\nselen (0,002 – 5) mg/l\nkadm (0,000024 – 10) mg/l\nołów (0,00036 – 10) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie metali\nZakres:\narsen (0,001 – 5) mg/l\nselen (0,002 – 5) mg/l\nkadm (0,000024 – 10) mg/l\nołów (0,00036 – 10) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda Stezenie metali\nZakres:\narsen (0,001 – 5) mg/l\nselen (0,002 – 5) mg/l\nkadm (0,000024 – 10) mg/l\nolow (0,00036 – 10) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["materials","water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"arsenic","range":"(0,001 – 5) mg/l"},{"name":"selenium","range":"(0,002 – 5) mg/l"},{"name":"cadmium","range":"(0,000024 – 10) mg/l"},{"name":"lead","range":"(0,00036 – 10) mg/l"}],"search_en":"Water Metal concentrations Electrothermal atomization atomic absorption spectrometry (ETAAS) arsenic selenium cadmium lead PN-EN ISO 15586:2005","technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","test_object_en":"Water","methodology_zh":"金属浓度","parameters_zh":[{"name":"砷","range":"(0,001 – 5) mg/l"},{"name":"硒","range":"(0,002 – 5) mg/l"},{"name":"镉","range":"(0,000024 – 10) mg/l"},{"name":"铅","range":"(0,00036 – 10) mg/l"}],"search_zh":"水 金属浓度 电热原子化原子吸收光谱法（ETAAS） 砷 硒 镉 铅 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"水"},{"_id":"6a8321c2884ede9a1b2c4d4b","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie metali","parameters":[{"name":"kadm","range":"(0,000024 – 10) mg/l"},{"name":"ołów","range":"(0,00036 – 10) mg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nkadm (0,000024 – 10) mg/l\nołów (0,00036 – 10) mg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2: 2024-4","norm_bases":["PN-EN ISO 17294-2: 2024-4"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie metali\nZakres:\nkadm (0,000024 – 10) mg/l\nołów (0,00036 – 10) mg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2: 2024-4 Woda Stezenie metali\nZakres:\nkadm (0,000024 – 10) mg/l\nolow (0,00036 – 10) mg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2: 2024-4","categories":["materials","water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"cadmium","range":"(0,000024 – 10) mg/l"},{"name":"lead","range":"(0,00036 – 10) mg/l"}],"search_en":"Water Metal concentrations Inductively coupled plasma mass spectrometry (ICP-MS) cadmium lead PN-EN ISO 17294-2: 2024-4","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Water","methodology_zh":"金属浓度","parameters_zh":[{"name":"镉","range":"(0,000024 – 10) mg/l"},{"name":"铅","range":"(0,00036 – 10) mg/l"}],"search_zh":"水 金属浓度 电感耦合等离子体质谱法（ICP-MS） 镉 铅 PN-EN ISO 17294-2: 2024-4","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"水"},{"_id":"6a8321c2884ede9a1b2c4d4c","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,01 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,01 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 rozdz. 7 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 rozdz. 7","PN-EN ISO 6878:2006/Ap1:2010","PN-EN ISO 6878:2006/Ap2:2010"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie fosforu ogólnego\nZakres (0,01 – 50) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 rozdz. 7 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010 Woda Stezenie fosforu ogolnego\nZakres (0,01 – 50) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 rozdz. 7 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,01 – 50) mg/l"}],"search_en":"Water Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 rozdz. 7 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 50) mg/l"}],"search_zh":"水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 rozdz. 7 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a8321c2884ede9a1b2c4d4d","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie metali","parameters":[{"name":"kadm","range":"(0,0001 – 10) mg/l"},{"name":"ołów","range":"(0,001 – 10) mg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nkadm (0,0001 – 10) mg/l\nołów (0,001 – 10) mg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2: 2024-4","norm_bases":["PN-EN ISO 17294-2: 2024-4"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie metali\nZakres:\nkadm (0,0001 – 10) mg/l\nołów (0,001 – 10) mg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2: 2024-4 Scieki Stezenie metali\nZakres:\nkadm (0,0001 – 10) mg/l\nolow (0,001 – 10) mg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2: 2024-4","categories":["materials","water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"cadmium","range":"(0,0001 – 10) mg/l"},{"name":"lead","range":"(0,001 – 10) mg/l"}],"search_en":"Wastewater Metal concentrations Inductively coupled plasma mass spectrometry (ICP-MS) cadmium lead PN-EN ISO 17294-2: 2024-4","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Wastewater","methodology_zh":"金属浓度","parameters_zh":[{"name":"镉","range":"(0,0001 – 10) mg/l"},{"name":"铅","range":"(0,001 – 10) mg/l"}],"search_zh":"污水 金属浓度 电感耦合等离子体质谱法（ICP-MS） 镉 铅 PN-EN ISO 17294-2: 2024-4","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"污水"},{"_id":"6a8321c2884ede9a1b2c4d4e","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie metali","parameters":[{"name":"kadm","range":"(0,0001 – 10) mg/l"},{"name":"ołów","range":"(0,001 – 10) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nkadm (0,0001 – 10) mg/l\nołów (0,001 – 10) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie metali\nZakres:\nkadm (0,0001 – 10) mg/l\nołów (0,001 – 10) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Scieki Stezenie metali\nZakres:\nkadm (0,0001 – 10) mg/l\nolow (0,001 – 10) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["materials","water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"cadmium","range":"(0,0001 – 10) mg/l"},{"name":"lead","range":"(0,001 – 10) mg/l"}],"search_en":"Wastewater Metal concentrations Electrothermal atomization atomic absorption spectrometry (ETAAS) cadmium lead PN-EN ISO 15586:2005","technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","test_object_en":"Wastewater","methodology_zh":"金属浓度","parameters_zh":[{"name":"镉","range":"(0,0001 – 10) mg/l"},{"name":"铅","range":"(0,001 – 10) mg/l"}],"search_zh":"污水 金属浓度 电热原子化原子吸收光谱法（ETAAS） 镉 铅 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"污水"},{"_id":"6a8321c2884ede9a1b2c4d4f","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,0030 – 5,0) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,0030 – 5,0) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14402:2004 p. 4","norm_bases":["PN-EN ISO 14402:2004 p. 4"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks fenolowy\nZakres (0,0030 – 5,0) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 14402:2004 p. 4 Woda, scieki Indeks fenolowy\nZakres (0,0030 – 5,0) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 14402:2004 p. 4","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,0030 – 5,0) mg/l"}],"search_en":"Water, wastewater Phenol index Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 14402:2004 p. 4","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,0030 – 5,0) mg/l"}],"search_zh":"水、废水 酚指数 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 14402:2004 p. 4","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、废水","methodology_zh":"酚指数"},{"_id":"6a8321c2884ede9a1b2c4d50","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,3 – 100) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,3 – 100) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (0,3 – 100) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (0,3 – 100) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,3 – 100) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,3 – 100) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a8321c2884ede9a1b2c4d51","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie lotnych związków organicznych (VOC)","parameters":[{"name":"Trichloroetylen","range":"(1,0 – 100) µg/l"},{"name":"Tetrachloroetylen","range":"(1,0 – 100) µg/l"},{"name":"Trichlorometan","range":"( 0,5 – 100) µg/l"},{"name":"Benzen","range":"(1,0 – 100) µg/l"},{"name":"Toluen","range":"(1,0 – 100) µg/l"},{"name":"m,p-Ksylen","range":"(2,0 – 200) µg/l"},{"name":"o-Ksylen","range":"(1,0 – 100) µg/l"},{"name":"1,2- Dichloroetan","range":"(1,0 – 100) µg/l"},{"name":"Heksachlorobutadien","range":"(0,18 – 100) µg/l"}],"technique":"Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","techniques":["Metoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)"],"computed":[],"activity":"Stężenie lotnych związków organicznych (VOC)\nZakres:\nTrichloroetylen (1,0 – 100) µg/l\nTetrachloroetylen (1,0 – 100) µg/l\nTrichlorometan ( 0,5 – 100) µg/l\nBenzen (1,0 – 100) µg/l\nToluen (1,0 – 100) µg/l\nm,p-Ksylen (2,0 – 200) µg/l\no-Ksylen (1,0 – 100) µg/l\n1,2- Dichloroetan (1,0 – 100) µg/l\nHeksachlorobutadien (0,18 – 100) µg/l\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie lotnych związków organicznych (VOC)\nZakres:\nTrichloroetylen (1,0 – 100) µg/l\nTetrachloroetylen (1,0 – 100) µg/l\nTrichlorometan ( 0,5 – 100) µg/l\nBenzen (1,0 – 100) µg/l\nToluen (1,0 – 100) µg/l\nm,p-Ksylen (2,0 – 200) µg/l\no-Ksylen (1,0 – 100) µg/l\n1,2- Dichloroetan (1,0 – 100) µg/l\nHeksachlorobutadien (0,18 – 100) µg/l\nMetoda chromatografii gazowej z techniką wyłapywania i wypłukiwania (Purge&Trap) i detekcją spektrometrią mas (P&T GC-MS) PN-EN ISO 15680:2008 Woda, scieki Stezenie lotnych zwiazkow organicznych (VOC)\nZakres:\nTrichloroetylen (1,0 – 100) µg/l\nTetrachloroetylen (1,0 – 100) µg/l\nTrichlorometan ( 0,5 – 100) µg/l\nBenzen (1,0 – 100) µg/l\nToluen (1,0 – 100) µg/l\nm,p-Ksylen (2,0 – 200) µg/l\no-Ksylen (1,0 – 100) µg/l\n1,2- Dichloroetan (1,0 – 100) µg/l\nHeksachlorobutadien (0,18 – 100) µg/l\nMetoda chromatografii gazowej z technika wylapywania i wyplukiwania (Purge&Trap) i detekcja spektrometria mas (P&T GC-MS) PN-EN ISO 15680:2008","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile organic compound (VOC) concentration","parameters_en":[{"name":"Trichloroethylene","range":"(1,0 – 100) µg/l"},{"name":"Tetrachloroethylene","range":"(1,0 – 100) µg/l"},{"name":"Trichloromethane","range":"( 0,5 – 100) µg/l"},{"name":"Benzene","range":"(1,0 – 100) µg/l"},{"name":"Toluene","range":"(1,0 – 100) µg/l"},{"name":"m,p-Xylene","range":"(2,0 – 200) µg/l"},{"name":"o-Xylene","range":"(1,0 – 100) µg/l"},{"name":"1,2- Dichloroetan","range":"(1,0 – 100) µg/l"},{"name":"Hexachlorobutadiene","range":"(0,18 – 100) µg/l"}],"search_en":"Water, wastewater Volatile organic compound (VOC) concentration Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS) Trichloroethylene Tetrachloroethylene Trichloromethane Benzene Toluene m,p-Xylene o-Xylene Hexachlorobutadiene PN-EN ISO 15680:2008","technique_en":"Gas chromatography with purge and trap technique (Purge&Trap) and mass spectrometry detection (P&T GC-MS)","test_object_en":"Water, wastewater","search_zh":"水、废水 挥发性有机化合物（VOC）浓度 吹扫捕集气相色谱-质谱法（P&T GC-MS） 三氯甲烷 苯 甲苯 邻二甲苯 六氯丁二烯 PN-EN ISO 15680:2008","test_object_zh":"水、废水","parameters_zh":[{"name":"Trichloroetylen","range":"(1,0 – 100) µg/l"},{"name":"Tetrachloroetylen","range":"(1,0 – 100) µg/l"},{"name":"三氯甲烷","range":"( 0,5 – 100) µg/l"},{"name":"苯","range":"(1,0 – 100) µg/l"},{"name":"甲苯","range":"(1,0 – 100) µg/l"},{"name":"m,p-Ksylen","range":"(2,0 – 200) µg/l"},{"name":"邻二甲苯","range":"(1,0 – 100) µg/l"},{"name":"1,2- Dichloroetan","range":"(1,0 – 100) µg/l"},{"name":"六氯丁二烯","range":"(0,18 – 100) µg/l"}],"technique_zh":"吹扫捕集气相色谱-质谱法（P&T GC-MS）","methodology_zh":"挥发性有机化合物（VOC）浓度"},{"_id":"6a8321c2884ede9a1b2c4d52","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotanowego i azotu azotynowego (suma)","parameters":[{"name":"Zakres","range":"(0,10 – 500) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu azotanowego i azotu azotynowego (suma)\nZakres (0,10 – 500) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotanowego i azotu azotynowego (suma)\nZakres (0,10 – 500) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda, scieki Stezenie azotu azotanowego i azotu azotynowego (suma)\nZakres (0,10 – 500) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen and nitrite nitrogen concentration (sum)","parameters_en":[{"name":"Range","range":"(0,10 – 500) mg/l"}],"search_en":"Water, wastewater Nitrate nitrogen and nitrite nitrogen concentration (sum) Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 500) mg/l"}],"search_zh":"水、废水 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、废水"},{"_id":"6a8321c2884ede9a1b2c4d53","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,0010 – 100) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,0010 – 100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,0010 – 100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda, scieki Stezenie azotu azotynowego\nZakres (0,0010 – 100) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,0010 – 100) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,0010 – 100) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、废水"},{"_id":"6a8321c2884ede9a1b2c4d54","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotanowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu azotanowego (z obliczeń)","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotanowego (z obliczeń) PN-EN ISO 13395:2001 Woda, scieki Stezenie azotu azotanowego (z obliczen) PN-EN ISO 13395:2001","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration (calculated)","search_en":"Water, wastewater Nitrate nitrogen concentration (calculated) PN-EN ISO 13395:2001","test_object_en":"Water, wastewater","search_zh":"水、废水 硝酸盐氮浓度（由计算得出） PN-EN ISO 13395:2001","test_object_zh":"水、废水","methodology_zh":"硝酸盐氮浓度（由计算得出）"},{"_id":"6a8321c2884ede9a1b2c4d55","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotanów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotanów (z obliczeń)","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotanów (z obliczeń) PN-EN ISO 13395:2001 Woda, scieki Stezenie azotanow (z obliczen) PN-EN ISO 13395:2001","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration (calculated)","search_en":"Water, wastewater Nitrate concentration (calculated) PN-EN ISO 13395:2001","test_object_en":"Water, wastewater","search_zh":"水、废水 硝酸盐浓度（由计算得出） PN-EN ISO 13395:2001","test_object_zh":"水、废水","methodology_zh":"硝酸盐浓度（由计算得出）"},{"_id":"6a8321c2884ede9a1b2c4d56","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotynów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotynów (z obliczeń)","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotynów (z obliczeń) PN-EN ISO 13395:2001 Woda, scieki Stezenie azotynow (z obliczen) PN-EN ISO 13395:2001","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration (calculated)","search_en":"Water, wastewater Nitrite concentration (calculated) PN-EN ISO 13395:2001","test_object_en":"Water, wastewater","search_zh":"水、废水 亚硝酸盐浓度（由计算得出） PN-EN ISO 13395:2001","test_object_zh":"水、废水","methodology_zh":"亚硝酸盐浓度（由计算得出）"},{"_id":"6a8321c2884ede9a1b2c4d57","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,01 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,01 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,01 – 100) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,01 – 100) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,01 – 100) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 100) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a8321c2884ede9a1b2c4d58","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie jonu amonowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie jonu amonowego (z obliczeń)","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie jonu amonowego (z obliczeń) PN-ISO 7150-1:2002 Woda, scieki Stezenie jonu amonowego (z obliczen) PN-ISO 7150-1:2002","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration (calculated)","search_en":"Water, wastewater Ammonium ion concentration (calculated) PN-ISO 7150-1:2002","test_object_en":"Water, wastewater","search_zh":"水、废水 铵离子浓度（由计算得出） PN-ISO 7150-1:2002","test_object_zh":"水、废水","methodology_zh":"铵离子浓度（由计算得出）"},{"_id":"6a8321c2884ede9a1b2c4d59","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie amoniaku (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie amoniaku (z obliczeń)","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie amoniaku (z obliczeń) PN-ISO 7150-1:2002 Woda, scieki Stezenie amoniaku (z obliczen) PN-ISO 7150-1:2002","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia concentration (calculated)","search_en":"Water, wastewater Ammonia concentration (calculated) PN-ISO 7150-1:2002","test_object_en":"Water, wastewater","search_zh":"水、废水 氨浓度（由计算得出） PN-ISO 7150-1:2002","test_object_zh":"水、废水","methodology_zh":"氨浓度（由计算得出）"},{"_id":"6a8321c2884ede9a1b2c4d5a","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,010 – 10) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,010 – 10) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 11732:2007","norm_bases":["PN-EN ISO 11732:2007"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,010 – 10) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 11732:2007 Woda, scieki Stezenie azotu amonowego\nZakres (0,010 – 10) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 11732:2007","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,010 – 10) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 11732:2007","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 10) mg/l"}],"search_zh":"水、废水 氨氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 11732:2007","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、废水"},{"_id":"6a8321c2884ede9a1b2c4d5b","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie jonu amonowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie jonu amonowego (z obliczeń)","reference":"PN-EN ISO 11732:2007","norm_bases":["PN-EN ISO 11732:2007"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie jonu amonowego (z obliczeń) PN-EN ISO 11732:2007 Woda, scieki Stezenie jonu amonowego (z obliczen) PN-EN ISO 11732:2007","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration (calculated)","search_en":"Water, wastewater Ammonium ion concentration (calculated) PN-EN ISO 11732:2007","test_object_en":"Water, wastewater","search_zh":"水、废水 铵离子浓度（由计算得出） PN-EN ISO 11732:2007","test_object_zh":"水、废水","methodology_zh":"铵离子浓度（由计算得出）"},{"_id":"6a8321c2884ede9a1b2c4d5c","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie amoniaku (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie amoniaku (z obliczeń)","reference":"PN-EN ISO 11732:2007","norm_bases":["PN-EN ISO 11732:2007"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie amoniaku (z obliczeń) PN-EN ISO 11732:2007 Woda, scieki Stezenie amoniaku (z obliczen) PN-EN ISO 11732:2007","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia concentration (calculated)","search_en":"Water, wastewater Ammonia concentration (calculated) PN-EN ISO 11732:2007","test_object_en":"Water, wastewater","search_zh":"水、废水 氨浓度（由计算得出） PN-EN ISO 11732:2007","test_object_zh":"水、废水","methodology_zh":"氨浓度（由计算得出）"},{"_id":"6a8321c2884ede9a1b2c4d5d","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-26/CLB wyd.1 z dnia 16.01.2026r.","norm_bases":["PB-26/CLB wyd.1 z dnia 16.01.2026r."],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PB-26/CLB wyd.1 z dnia 16.01.2026r. Woda, scieki Stezenie azotu ogolnego (z obliczen) PB-26/CLB wyd.1 z dnia 16.01.2026r.","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, wastewater Total nitrogen concentration (calculated) PB-26/CLB wyd.1 z dnia 16.01.2026r.","test_object_en":"Water, wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PB-26/CLB wyd.1 z dnia 16.01.2026r.","test_object_zh":"水、废水"},{"_id":"6a8321c2884ede9a1b2c4d5e","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 5000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 – 5000) mg/l"}],"search_en":"Water, wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 5000) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a8321c2884ede9a1b2c4d5f","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(1 – 6000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a8321c2884ede9a1b2c4d60","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(0,6 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,6 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,6 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,6 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(0,6 – 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,6 – 6,0) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a8321c2884ede9a1b2c4d61","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,03 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,03 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 rozdz. 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 rozdz. 8","PN-EN ISO 6878:2006/Ap1:2010","PN-EN ISO 6878:2006/Ap2:2010"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,03 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 rozdz. 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,03 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 rozdz. 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,03 – 100) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 rozdz. 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,03 – 100) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 rozdz. 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a8321c2884ede9a1b2c4d62","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie ortofosforanów rozpuszczonych","parameters":[{"name":"Zakres","range":"(0,030 – 300) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie ortofosforanów rozpuszczonych\nZakres (0,030 – 300) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 15681-2:2019-02","norm_bases":["PN-EN ISO 15681-2:2019-02"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie ortofosforanów rozpuszczonych\nZakres (0,030 – 300) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 15681-2:2019-02 Woda, scieki Stezenie ortofosforanow rozpuszczonych\nZakres (0,030 – 300) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 15681-2:2019-02","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,030 – 300) mg/l"}],"search_en":"Water, wastewater Dissolved orthophosphate concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 15681-2:2019-02","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,030 – 300) mg/l"}],"search_zh":"水、废水 溶解性正磷酸盐浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 15681-2:2019-02","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、废水","methodology_zh":"溶解性正磷酸盐浓度"},{"_id":"6a8321c2884ede9a1b2c4d63","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(5 – 2000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (5 – 2000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (5 – 2000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (5 – 2000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(5 – 2000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(5 – 2000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a8321c2884ede9a1b2c4d64","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks oleju mineralnego / węglowodory ropopochodne C10-C40","parameters":[{"name":"Zakres","range":"(0,05 – 100) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego / węglowodory ropopochodne C10-C40\nZakres (0,05 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks oleju mineralnego / węglowodory ropopochodne C10-C40\nZakres (0,05 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki Indeks oleju mineralnego / weglowodory ropopochodne C10-C40\nZakres (0,05 – 100) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index / petroleum hydrocarbons C10-C40","parameters_en":[{"name":"Range","range":"(0,05 – 100) mg/l"}],"search_en":"Water, wastewater Mineral oil index / petroleum hydrocarbons C10-C40 Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,05 – 100) mg/l"}],"search_zh":"水、废水 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、废水"},{"_id":"6a8321c2884ede9a1b2c4d65","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie ortofosforanów rozpuszczonych","parameters":[{"name":"Zakres","range":"(0,03 – 300) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów rozpuszczonych\nZakres (0,03 – 300) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 rozdz. 4 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 rozdz. 4","PN-EN ISO 6878:2006/Ap1:2010","PN-EN ISO 6878:2006/Ap2:2010"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie ortofosforanów rozpuszczonych\nZakres (0,03 – 300) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 rozdz. 4 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010 Woda, scieki Stezenie ortofosforanow rozpuszczonych\nZakres (0,03 – 300) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 rozdz. 4 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,03 – 300) mg/l"}],"search_en":"Water, wastewater Dissolved orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 rozdz. 4 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,03 – 300) mg/l"}],"search_zh":"水、废水 溶解性正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 rozdz. 4 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"溶解性正磷酸盐浓度"},{"_id":"6a8321c2884ede9a1b2c4d66","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie metali","parameters":[{"name":"chrom","range":"(0,001 – 10) mg/l"},{"name":"glin","range":"(0,005 – 10) mg/l"},{"name":"mangan","range":"(0,001 – 10) mg/l"},{"name":"miedź","range":"(0,001 – 10) mg/l"},{"name":"nikiel","range":"(0,001 – 10) mg/l"},{"name":"żelazo","range":"(0,005 – 10) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nchrom (0,001 – 10) mg/l\nglin (0,005 – 10) mg/l\nmangan (0,001 – 10) mg/l\nmiedź (0,001 – 10) mg/l\nnikiel (0,001 – 10) mg/l\nżelazo (0,005 – 10) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie metali\nZakres:\nchrom (0,001 – 10) mg/l\nglin (0,005 – 10) mg/l\nmangan (0,001 – 10) mg/l\nmiedź (0,001 – 10) mg/l\nnikiel (0,001 – 10) mg/l\nżelazo (0,005 – 10) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda, scieki Stezenie metali\nZakres:\nchrom (0,001 – 10) mg/l\nglin (0,005 – 10) mg/l\nmangan (0,001 – 10) mg/l\nmiedz (0,001 – 10) mg/l\nnikiel (0,001 – 10) mg/l\nzelazo (0,005 – 10) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["materials","water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"chromium","range":"(0,001 – 10) mg/l"},{"name":"aluminium","range":"(0,005 – 10) mg/l"},{"name":"manganese","range":"(0,001 – 10) mg/l"},{"name":"copper","range":"(0,001 – 10) mg/l"},{"name":"nickel","range":"(0,001 – 10) mg/l"},{"name":"iron","range":"(0,005 – 10) mg/l"}],"search_en":"Water, wastewater Metal concentrations Electrothermal atomization atomic absorption spectrometry (ETAAS) chromium aluminium manganese copper nickel iron PN-EN ISO 15586:2005","technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","test_object_en":"Water, wastewater","methodology_zh":"金属浓度","parameters_zh":[{"name":"铬","range":"(0,001 – 10) mg/l"},{"name":"铝","range":"(0,005 – 10) mg/l"},{"name":"锰","range":"(0,001 – 10) mg/l"},{"name":"铜","range":"(0,001 – 10) mg/l"},{"name":"镍","range":"(0,001 – 10) mg/l"},{"name":"铁","range":"(0,005 – 10) mg/l"}],"search_zh":"水、废水 金属浓度 电热原子化原子吸收光谱法（ETAAS） 铬 铝 锰 铜 镍 铁 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"水、废水"},{"_id":"6a8321c2884ede9a1b2c4d67","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie ogólnego węgla organicznego","parameters":[{"name":"Zakres","range":"(2,0 – 200) mg/l"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego\nZakres (2,0 – 200) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie ogólnego węgla organicznego\nZakres (2,0 – 200) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999 Woda, scieki Stezenie ogolnego wegla organicznego\nZakres (2,0 – 200) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon concentration","parameters_en":[{"name":"Range","range":"(2,0 – 200) mg/l"}],"search_en":"Water, wastewater Total organic carbon concentration Spectrometry method in the infrared range IR Range PN-EN 1484:1999","technique_en":"Spectrometry method in the infrared range IR","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(2,0 – 200) mg/l"}],"search_zh":"水、废水 总有机碳浓度 红外光谱法 IR 范围 PN-EN 1484:1999","test_object_zh":"水、废水","technique_zh":"红外光谱法 IR","methodology_zh":"总有机碳浓度"},{"_id":"6a8321c2884ede9a1b2c4d68","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 3000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 3000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 3000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a8321c2884ede9a1b2c4d69","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie pierwiastków","parameters":[{"name":"cynku","range":"(0,0050 – 100) mg/l"},{"name":"żelaza","range":"(0,050 – 100) mg/l"},{"name":"manganu","range":"(0,0050 – 100) mg/l"},{"name":"fosforu ogólnego","range":"(0,010 – 20) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\ncynku (0,0050 – 100) mg/l\nżelaza (0,050 – 100) mg/l\nmanganu (0,0050 – 100) mg/l\nfosforu ogólnego (0,010 – 20) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie pierwiastków\nZakres:\ncynku (0,0050 – 100) mg/l\nżelaza (0,050 – 100) mg/l\nmanganu (0,0050 – 100) mg/l\nfosforu ogólnego (0,010 – 20) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie pierwiastkow\nZakres:\ncynku (0,0050 – 100) mg/l\nzelaza (0,050 – 100) mg/l\nmanganu (0,0050 – 100) mg/l\nfosforu ogolnego (0,010 – 20) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"zinc","range":"(0,0050 – 100) mg/l"},{"name":"iron","range":"(0,050 – 100) mg/l"},{"name":"manganese","range":"(0,0050 – 100) mg/l"},{"name":"total phosphorus","range":"(0,010 – 20) mg/l"}],"search_en":"Water, wastewater Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) zinc iron manganese total phosphorus PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, wastewater","methodology_zh":"元素浓度","search_zh":"水、废水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 锌 铁 锰 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、废水","parameters_zh":[{"name":"锌","range":"(0,0050 – 100) mg/l"},{"name":"铁","range":"(0,050 – 100) mg/l"},{"name":"锰","range":"(0,0050 – 100) mg/l"},{"name":"fosforu ogólnego","range":"(0,010 – 20) mg/l"}]},{"_id":"6a8321c2884ede9a1b2c4d6a","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,013 – 100) µg/l"}],"technique":"Metoda atomowej spektrometrii fluorescencyjnej (AFS)","techniques":["Metoda atomowej spektrometrii fluorescencyjnej (AFS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,013 – 100) µg/l\nMetoda atomowej spektrometrii fluorescencyjnej (AFS)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie rtęci\nZakres (0,013 – 100) µg/l\nMetoda atomowej spektrometrii fluorescencyjnej (AFS) PN-EN ISO 17852:2009 Woda, scieki Stezenie rteci\nZakres (0,013 – 100) µg/l\nMetoda atomowej spektrometrii fluorescencyjnej (AFS) PN-EN ISO 17852:2009","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,013 – 100) µg/l"}],"search_en":"Water, wastewater Mercury concentration Atomic fluorescence spectrometry (AFS) Range PN-EN ISO 17852:2009","technique_en":"Atomic fluorescence spectrometry (AFS)","test_object_en":"Water, wastewater","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,013 – 100) µg/l"}],"search_zh":"水、废水 汞浓度 原子荧光光谱法（AFS） 范围 PN-EN ISO 17852:2009","test_object_zh":"水、废水","technique_zh":"原子荧光光谱法（AFS）"},{"_id":"6a8321c2884ede9a1b2c4d6b","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie metali","parameters":[{"name":"kobalt","range":"(0,010 – 1,0) mg/l"},{"name":"molibden","range":"(0,010 – 1,0) mg/l"},{"name":"wanad","range":"(0,010 – 2,0) mg/l"},{"name":"beryl","range":"(0,00020 – 1,0) mg/l"},{"name":"srebro","range":"(0,0010 – 0,1) mg/l"},{"name":"tal","range":"(0,0005 – 1,0) mg/l"},{"name":"antymon","range":"(0,0005 – 0,5) mg/l"},{"name":"miedź","range":"(0,0010 – 10) mg/l"},{"name":"chrom","range":"(0,0010 – 10) mg/l"},{"name":"nikiel","range":"(0,0010 – 10) mg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nkobalt (0,010 – 1,0) mg/l\nmolibden (0,010 – 1,0) mg/l\nwanad (0,010 – 2,0) mg/l\nberyl (0,00020 – 1,0) mg/l\nsrebro (0,0010 – 0,1) mg/l\ntal (0,0005 – 1,0) mg/l\nantymon (0,0005 – 0,5) mg/l\nmiedź (0,0010 – 10) mg/l\nchrom (0,0010 – 10) mg/l\nnikiel (0,0010 – 10) mg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2: 2024-4","norm_bases":["PN-EN ISO 17294-2: 2024-4"],"lab_section":"Pracownia w Szczecinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie metali\nZakres:\nkobalt (0,010 – 1,0) mg/l\nmolibden (0,010 – 1,0) mg/l\nwanad (0,010 – 2,0) mg/l\nberyl (0,00020 – 1,0) mg/l\nsrebro (0,0010 – 0,1) mg/l\ntal (0,0005 – 1,0) mg/l\nantymon (0,0005 – 0,5) mg/l\nmiedź (0,0010 – 10) mg/l\nchrom (0,0010 – 10) mg/l\nnikiel (0,0010 – 10) mg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2: 2024-4 Woda, scieki Stezenie metali\nZakres:\nkobalt (0,010 – 1,0) mg/l\nmolibden (0,010 – 1,0) mg/l\nwanad (0,010 – 2,0) mg/l\nberyl (0,00020 – 1,0) mg/l\nsrebro (0,0010 – 0,1) mg/l\ntal (0,0005 – 1,0) mg/l\nantymon (0,0005 – 0,5) mg/l\nmiedz (0,0010 – 10) mg/l\nchrom (0,0010 – 10) mg/l\nnikiel (0,0010 – 10) mg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2: 2024-4","categories":["materials","water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"cobalt","range":"(0,010 – 1,0) mg/l"},{"name":"molybdenum","range":"(0,010 – 1,0) mg/l"},{"name":"vanadium","range":"(0,010 – 2,0) mg/l"},{"name":"beryllium","range":"(0,00020 – 1,0) mg/l"},{"name":"silver","range":"(0,0010 – 0,1) mg/l"},{"name":"thallium","range":"(0,0005 – 1,0) mg/l"},{"name":"antimony","range":"(0,0005 – 0,5) mg/l"},{"name":"copper","range":"(0,0010 – 10) mg/l"},{"name":"chromium","range":"(0,0010 – 10) mg/l"},{"name":"nickel","range":"(0,0010 – 10) mg/l"}],"search_en":"Water, wastewater Metal concentrations Inductively coupled plasma mass spectrometry (ICP-MS) cobalt molybdenum vanadium beryllium silver thallium antimony copper chromium nickel PN-EN ISO 17294-2: 2024-4","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Water, wastewater","methodology_zh":"金属浓度","parameters_zh":[{"name":"钴","range":"(0,010 – 1,0) mg/l"},{"name":"钼","range":"(0,010 – 1,0) mg/l"},{"name":"钒","range":"(0,010 – 2,0) mg/l"},{"name":"铍","range":"(0,00020 – 1,0) mg/l"},{"name":"银","range":"(0,0010 – 0,1) mg/l"},{"name":"铊","range":"(0,0005 – 1,0) mg/l"},{"name":"锑","range":"(0,0005 – 0,5) mg/l"},{"name":"铜","range":"(0,0010 – 10) mg/l"},{"name":"铬","range":"(0,0010 – 10) mg/l"},{"name":"镍","range":"(0,0010 – 10) mg/l"}],"search_zh":"水、废水 金属浓度 电感耦合等离子体质谱法（ICP-MS） 钴 钼 钒 铍 银 铊 锑 铜 铬 镍 PN-EN ISO 17294-2: 2024-4","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"水、废水"},{"_id":"6a8321c2884ede9a1b2c4d6c","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,001 – 2,5) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,001 – 2,5) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu azotynowego\nZakres (0,001 – 2,5) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda Stezenie azotu azotynowego\nZakres (0,001 – 2,5) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,001 – 2,5) mg/l"}],"search_en":"Water Nitrite nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 2,5) mg/l"}],"search_zh":"水 亚硝态氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水"},{"_id":"6a8321c2884ede9a1b2c4d6d","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie rozpuszczonych jonów","parameters":[{"name":"azotany","range":"(0,44 – 50,0) mg/l"},{"name":"fluorki","range":"(0,10 – 10,0) mg/l"},{"name":"siarczany","range":"(2,5 – 100) mg/l"},{"name":"chlorki","range":"(1,0 – 300) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie rozpuszczonych jonów\nZakres:\nazotany (0,44 – 50,0) mg/l\nfluorki (0,10 – 10,0) mg/l\nsiarczany (2,5 – 100) mg/l\nchlorki (1,0 – 300) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","norm_bases":["PN-EN ISO 10304-1:2009","PN-EN ISO 10304-1:2009/AC:2012"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie rozpuszczonych jonów\nZakres:\nazotany (0,44 – 50,0) mg/l\nfluorki (0,10 – 10,0) mg/l\nsiarczany (2,5 – 100) mg/l\nchlorki (1,0 – 300) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012 Woda Stezenie rozpuszczonych jonow\nZakres:\nazotany (0,44 – 50,0) mg/l\nfluorki (0,10 – 10,0) mg/l\nsiarczany (2,5 – 100) mg/l\nchlorki (1,0 – 300) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved ion concentration","parameters_en":[{"name":"nitrates","range":"(0,44 – 50,0) mg/l"},{"name":"fluorides","range":"(0,10 – 10,0) mg/l"},{"name":"sulfates","range":"(2,5 – 100) mg/l"},{"name":"chlorides","range":"(1,0 – 300) mg/l"}],"search_en":"Water Dissolved ion concentration Ion chromatography with conductometric detection (IC-CD) nitrates fluorides sulfates chlorides PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water","search_zh":"水 溶解性离子浓度 离子色谱-电导检测法（IC-CD） 硝酸盐 氟化物 硫酸盐 氯化物 PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水","parameters_zh":[{"name":"硝酸盐","range":"(0,44 – 50,0) mg/l"},{"name":"氟化物","range":"(0,10 – 10,0) mg/l"},{"name":"硫酸盐","range":"(2,5 – 100) mg/l"},{"name":"氯化物","range":"(1,0 – 300) mg/l"}],"methodology_zh":"溶解性离子浓度"},{"_id":"6a8321c2884ede9a1b2c4d6e","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu azotanowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu azotanowego (z obliczeń)","reference":"PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","norm_bases":["PN-EN ISO 10304-1:2009","PN-EN ISO 10304-1:2009/AC:2012"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu azotanowego (z obliczeń) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012 Woda Stezenie azotu azotanowego (z obliczen) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","categories":["water"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration (calculated)","search_en":"Water Nitrate nitrogen concentration (calculated) PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","test_object_en":"Water","search_zh":"水 硝酸盐氮浓度（由计算得出） PN-EN ISO 10304-1:2009 | PN-EN ISO 10304-1:2009/AC:2012","test_object_zh":"水","methodology_zh":"硝酸盐氮浓度（由计算得出）"},{"_id":"6a8321c2884ede9a1b2c4d6f","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(0,03 – 200) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (0,03 – 200) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 11905-1:2001","norm_bases":["PN-EN ISO 11905-1:2001"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu ogólnego\nZakres (0,03 – 200) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 11905-1:2001 Woda Stezenie azotu ogolnego\nZakres (0,03 – 200) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 11905-1:2001","categories":["water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,03 – 200) mg/l"}],"search_en":"Water Total nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 11905-1:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(0,03 – 200) mg/l"}],"search_zh":"水 总氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 11905-1:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水"},{"_id":"6a8321c2884ede9a1b2c4d70","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"search_en":"Water Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a8321c2884ede9a1b2c4d71","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda","methodology":"Sumaryczne stężenie wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(5 – 500) mg/l CaCO3"},{"name":"Zakres","range":"(0,05 – 5) mmol/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczne stężenie wapnia i magnezu (twardość ogólna)\nZakres:\nZakres (5 – 500) mg/l CaCO3\nZakres (0,05 – 5) mmol/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Sumaryczne stężenie wapnia i magnezu (twardość ogólna)\nZakres:\nZakres (5 – 500) mg/l CaCO3\nZakres (0,05 – 5) mmol/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczne stezenie wapnia i magnezu (twardosc ogolna)\nZakres:\nZakres (5 – 500) mg/l CaCO3\nZakres (0,05 – 5) mmol/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total concentration of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(5 – 500) mg/l CaCO3"},{"name":"Range","range":"(0,05 – 5) mmol/l CaCO3"}],"search_en":"Water Total concentration of calcium and magnesium (total hardness) Titrimetric method Range Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(5 – 500) mg/l CaCO3"},{"name":"范围","range":"(0,05 – 5) mmol/l CaCO3"}],"search_zh":"水 钙与镁的总浓度（总硬度） 滴定法 范围 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水","methodology_zh":"钙与镁的总浓度（总硬度）"},{"_id":"6a8321c2884ede9a1b2c4d72","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda","methodology":"Zasadowość","parameters":[{"name":"Zakres","range":"(20 – 1000) mg/l CaCO3"},{"name":"Zakres","range":"(0,2 – 10) mmol/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość\nZakres:\nZakres (20 – 1000) mg/l CaCO3\nZakres (0,2 – 10) mmol/l CaCO3\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001/Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001","PN-EN ISO 9963-1:2001/Ap1:2004"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Zasadowość\nZakres:\nZakres (20 – 1000) mg/l CaCO3\nZakres (0,2 – 10) mmol/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001/Ap1:2004 Woda Zasadowosc\nZakres:\nZakres (20 – 1000) mg/l CaCO3\nZakres (0,2 – 10) mmol/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001/Ap1:2004","categories":["water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Alkalinity","parameters_en":[{"name":"Range","range":"(20 – 1000) mg/l CaCO3"},{"name":"Range","range":"(0,2 – 10) mmol/l CaCO3"}],"search_en":"Water Alkalinity Titrimetric method Range Range PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001/Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(20 – 1000) mg/l CaCO3"},{"name":"范围","range":"(0,2 – 10) mmol/l CaCO3"}],"search_zh":"水 碱度 滴定法 范围 范围 PN-EN ISO 9963-1:2001 | PN-EN ISO 9963-1:2001/Ap1:2004","technique_zh":"滴定法","test_object_zh":"水","methodology_zh":"碱度"},{"_id":"6a8321c2884ede9a1b2c4d73","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,3 – 10) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,3 – 10) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu Kjeldahla\nZakres (0,3 – 10) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda Stezenie azotu Kjeldahla\nZakres (0,3 – 10) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,3 – 10) mg/l"}],"search_en":"Water Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,3 – 10) mg/l"}],"search_zh":"水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a8321c2884ede9a1b2c4d74","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,10 – 250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,10 – 250) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,10 – 250) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Scieki Stezenie azotu azotanowego\nZakres (0,10 – 250) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,10 – 250) mg/l"}],"search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 250) mg/l"}],"search_zh":"污水 硝态氮浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a8321c2884ede9a1b2c4d75","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotanów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotanów (z obliczeń)","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotanów (z obliczeń) PN-82/C-04576.08 Scieki Stezenie azotanow (z obliczen) PN-82/C-04576.08","categories":["water"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration (calculated)","search_en":"Wastewater Nitrate concentration (calculated) PN-82/C-04576.08","test_object_en":"Wastewater","search_zh":"污水 硝酸盐浓度（由计算得出） PN-82/C-04576.08","test_object_zh":"污水","methodology_zh":"硝酸盐浓度（由计算得出）"},{"_id":"6a8321c2884ede9a1b2c4d76","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1,0 – 100) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,0 – 100) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (1,0 – 100) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla\nZakres (1,0 – 100) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 100) mg/l"}],"search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 100) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a8321c2884ede9a1b2c4d77","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,005 – 25) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,005 – 25) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres (0,005 – 25) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Scieki Stezenie azotu azotynowego\nZakres (0,005 – 25) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,005 – 25) mg/l"}],"search_en":"Wastewater Nitrite nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,005 – 25) mg/l"}],"search_zh":"污水 亚硝态氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"污水"},{"_id":"6a8321c2884ede9a1b2c4d78","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,010 – 100) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,010 – 100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 11732:2007","norm_bases":["PN-EN ISO 11732:2007"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,010 – 100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 11732:2007 Woda, scieki Stezenie azotu amonowego\nZakres (0,010 – 100) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 11732:2007","categories":["water"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,010 – 100) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 11732:2007","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 100) mg/l"}],"search_zh":"水、废水 氨氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 11732:2007","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、废水"},{"_id":"6a8321c2884ede9a1b2c4d79","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie jonu amonowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie jonu amonowego (z obliczeń)","reference":"PN-EN ISO 11732:2007","norm_bases":["PN-EN ISO 11732:2007"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie jonu amonowego (z obliczeń) PN-EN ISO 11732:2007 Woda, scieki Stezenie jonu amonowego (z obliczen) PN-EN ISO 11732:2007","categories":["water"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration (calculated)","search_en":"Water, wastewater Ammonium ion concentration (calculated) PN-EN ISO 11732:2007","test_object_en":"Water, wastewater","search_zh":"水、废水 铵离子浓度（由计算得出） PN-EN ISO 11732:2007","test_object_zh":"水、废水","methodology_zh":"铵离子浓度（由计算得出）"},{"_id":"6a8321c2884ede9a1b2c4d7a","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,05 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,05 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,05 – 100) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,05 – 100) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,05 – 100) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 100) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a8321c2884ede9a1b2c4d7b","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie jonu amonowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie jonu amonowego (z obliczeń)","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie jonu amonowego (z obliczeń) PN-ISO 7150-1:2002 Woda, scieki Stezenie jonu amonowego (z obliczen) PN-ISO 7150-1:2002","categories":["water"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration (calculated)","search_en":"Water, wastewater Ammonium ion concentration (calculated) PN-ISO 7150-1:2002","test_object_en":"Water, wastewater","search_zh":"水、废水 铵离子浓度（由计算得出） PN-ISO 7150-1:2002","test_object_zh":"水、废水","methodology_zh":"铵离子浓度（由计算得出）"},{"_id":"6a8321c2884ede9a1b2c4d7c","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotanowego i azotu azotynowego (suma)","parameters":[{"name":"Zakres","range":"(0,10 – 200) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu azotanowego i azotu azotynowego (suma)\nZakres (0,10 – 200) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotanowego i azotu azotynowego (suma)\nZakres (0,10 – 200) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda, scieki Stezenie azotu azotanowego i azotu azotynowego (suma)\nZakres (0,10 – 200) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen and nitrite nitrogen concentration (sum)","parameters_en":[{"name":"Range","range":"(0,10 – 200) mg/l"}],"search_en":"Water, wastewater Nitrate nitrogen and nitrite nitrogen concentration (sum) Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 200) mg/l"}],"search_zh":"水、废水 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、废水"},{"_id":"6a8321c2884ede9a1b2c4d7d","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotanowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu azotanowego (z obliczeń)","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotanowego (z obliczeń) PN-EN ISO 13395:2001 Woda, scieki Stezenie azotu azotanowego (z obliczen) PN-EN ISO 13395:2001","categories":["water"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration (calculated)","search_en":"Water, wastewater Nitrate nitrogen concentration (calculated) PN-EN ISO 13395:2001","test_object_en":"Water, wastewater","search_zh":"水、废水 硝酸盐氮浓度（由计算得出） PN-EN ISO 13395:2001","test_object_zh":"水、废水","methodology_zh":"硝酸盐氮浓度（由计算得出）"},{"_id":"6a8321c2884ede9a1b2c4d7e","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotanów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotanów (z obliczeń)","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotanów (z obliczeń) PN-EN ISO 13395:2001 Woda, scieki Stezenie azotanow (z obliczen) PN-EN ISO 13395:2001","categories":["water"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration (calculated)","search_en":"Water, wastewater Nitrate concentration (calculated) PN-EN ISO 13395:2001","test_object_en":"Water, wastewater","search_zh":"水、废水 硝酸盐浓度（由计算得出） PN-EN ISO 13395:2001","test_object_zh":"水、废水","methodology_zh":"硝酸盐浓度（由计算得出）"},{"_id":"6a8321c2884ede9a1b2c4d7f","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotynów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotynów (z obliczeń)","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotynów (z obliczeń) PN-EN ISO 13395:2001 Woda, scieki Stezenie azotynow (z obliczen) PN-EN ISO 13395:2001","categories":["water"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration (calculated)","search_en":"Water, wastewater Nitrite concentration (calculated) PN-EN ISO 13395:2001","test_object_en":"Water, wastewater","search_zh":"水、废水 亚硝酸盐浓度（由计算得出） PN-EN ISO 13395:2001","test_object_zh":"水、废水","methodology_zh":"亚硝酸盐浓度（由计算得出）"},{"_id":"6a8321c2884ede9a1b2c4d80","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,001 – 2,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,001 – 2,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,001 – 2,5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,001 – 2,5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,001 – 2,5) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 2,5) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a8321c2884ede9a1b2c4d81","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotynów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotynów (z obliczeń)","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotynów (z obliczeń) PN-EN 26777:1999 Woda, scieki Stezenie azotynow (z obliczen) PN-EN 26777:1999","categories":["water"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration (calculated)","search_en":"Water, wastewater Nitrite concentration (calculated) PN-EN 26777:1999","test_object_en":"Water, wastewater","search_zh":"水、废水 亚硝酸盐浓度（由计算得出） PN-EN 26777:1999","test_object_zh":"水、废水","methodology_zh":"亚硝酸盐浓度（由计算得出）"},{"_id":"6a8321c2884ede9a1b2c4d82","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576.14","norm_bases":["PN-73/C-04576.14"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576.14 Woda, scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576.14","categories":["water"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, wastewater Total nitrogen concentration (calculated) PN-73/C-04576.14","test_object_en":"Water, wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PN-73/C-04576.14","test_object_zh":"水、废水"},{"_id":"6a8321c2884ede9a1b2c4d83","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(1 – 6000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a8321c2884ede9a1b2c4d84","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(4,0 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (4,0 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (4,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (4,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(4,0 – 10000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(4,0 – 10000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a8321c2884ede9a1b2c4d85","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 10000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 10000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (5,0 – 10000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (5,0 – 10000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 10000) mg/l"}],"search_en":"Water, wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 10000) mg/l"}],"search_zh":"水、废水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a8321c2884ede9a1b2c4d86","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu","parameters":[{"name":"Zakres","range":"(0,005 – 200,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu\nZakres (0,005 – 200,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p. 7 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p. 7","PN-EN ISO 6878:2006/Ap1:2010","PN-EN ISO 6878:2006/Ap2:2010"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu\nZakres (0,005 – 200,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 7 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010 Woda, scieki Stezenie fosforu\nZakres (0,005 – 200,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 7 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","categories":["water"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,005 – 200,0) mg/l"}],"search_en":"Water, wastewater Phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 p. 7 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,005 – 200,0) mg/l"}],"search_zh":"水、废水 磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 p. 7 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"磷浓度"},{"_id":"6a8321c2884ede9a1b2c4d87","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie ortofosforanów","parameters":[{"name":"Zakres","range":"(0,015 – 25,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów\nZakres (0,015 – 25,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p. 4 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p. 4","PN-EN ISO 6878:2006/Ap1:2010","PN-EN ISO 6878:2006/Ap2:2010"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie ortofosforanów\nZakres (0,015 – 25,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 4 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010 Woda, scieki Stezenie ortofosforanow\nZakres (0,015 – 25,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 4 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","categories":["water"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,015 – 25,0) mg/l"}],"search_en":"Water, wastewater Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 p. 4 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,015 – 25,0) mg/l"}],"search_zh":"水、废水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 p. 4 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a8321c2884ede9a1b2c4d88","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 5000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 – 5000) mg/l"}],"search_en":"Water, wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 5000) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a8321c2884ede9a1b2c4d89","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie substancji rozpuszczonych","parameters":[{"name":"Zakres","range":"(1 – 3000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji rozpuszczonych\nZakres (1 – 3000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie substancji rozpuszczonych\nZakres (1 – 3000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda, scieki Stezenie substancji rozpuszczonych\nZakres (1 – 3000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved solids concentration","parameters_en":[{"name":"Range","range":"(1 – 3000) mg/l"}],"search_en":"Water, wastewater Dissolved solids concentration Gravimetric method Range PN-EN 15216:2022-03","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(1 – 3000) mg/l"}],"search_zh":"水、废水 溶解性物质浓度 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"溶解性物质浓度"},{"_id":"6a8321c2884ede9a1b2c4d8a","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(2 – 200) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres (2 – 200) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie wapnia\nZakres (2 – 200) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, scieki Stezenie wapnia\nZakres (2 – 200) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(2 – 200) mg/l"}],"search_en":"Water, wastewater Calcium concentration Titrimetric method Range PN-ISO 6058:1999","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(2 – 200) mg/l"}],"search_zh":"水、废水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"钙浓度"},{"_id":"6a8321c2884ede9a1b2c4d8b","lab_id":"69ad52a3de79e566650fb159","country":"PL","accr_number":"AB 177","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 3000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007","norm_bases":["PN-EN 872:2007","PN-EN 872:2007/Ap1:2007"],"lab_section":"Pracownia w Koszalinie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007","categories":["water"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 3000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 3000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"}],"has_pdf":true}