{"lab":{"_id":"69ad52a3de79e566650fb961","accr_number":"AB 1769","country":"PL","accr_body":"PCA","address":"ul. Waryńskiego 1, 78-400 Szczecinek","categories":["construction","materials","environment"],"city":"Szczecinek","imported_at":"2026-03-08T10:42:43.265Z","methods_count":3,"name":"KRONOSPAN POLSKA Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1769.pdf"],"scope_summary":"","search_text":"kronospan polska sp. z o.o. ul. waryńskiego 1, 78-400 szczecinek materials environment construction other metrology","status":"active","updated_at":"2026-03-08T14:50:53.770Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:53.770Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201769,podmiot.html","fields_of_testing":[{"codes":"C5; C/8; C/11","pl":"Badania chemiczne wyrobów i materiałów budowlanych, wyrobów i materiałów konstrukcyjnych, mebli","en":"Chemical tests of building products and materials, construction products and materials, furniture."}],"issue":{"no":"4","date":"08.01.2025"},"parse_date":"2026-07-20T07:09:57.090Z","parse_source":"script-pdfplumber","map_coord":[53.692665,16.708325],"map_geo":"nominatim-street","has_en":true,"category_counts":{"construction":3,"materials":3,"environment":3},"category_scores":{"construction":1,"materials":1,"environment":1},"has_zh":true},"methods":[{"_id":"6a5dc9c5f1c10c8ce82602c6","lab_id":"69ad52a3de79e566650fb961","country":"PL","accr_number":"AB 1769","accr_body":"PCA","test_object":"Wyroby i materiały budowlane, Wyroby i materiały konstrukcyjne, Meble","test_object_en":"Building products and materials, Structural products and materials, Furniture","methodology":"Emisja formaldehydu w warunkach dynamicznych (duża i mała komora)","methodology_en":"Formaldehyde emission under dynamic conditions (large and small chamber)","parameters":[{"name":"Zakres","range":"(0,005 – 0,600) mg/m3"},{"name":"Zakres","range":"(0,004 – 0,483) ppm"}],"parameters_en":[{"name":"Range","range":"(0,005 – 0,600) mg/m3"},{"name":"Range","range":"(0,004 – 0,483) ppm"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","computed":[],"computed_en":[],"activity":"Emisja formaldehydu w warunkach dynamicznych (duża i mała komora)\nZakres:\nZakres (0,005 – 0,600) mg/m3\nZakres (0,004 – 0,483) ppm\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"PN-EN 16516+A1:2020-12","norm_bases":["PN-EN 16516+A1:2020-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i materiały budowlane, Wyroby i materiały konstrukcyjne, Meble Emisja formaldehydu w warunkach dynamicznych (duża i mała komora)\nZakres:\nZakres (0,005 – 0,600) mg/m3\nZakres (0,004 – 0,483) ppm\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) PN-EN 16516+A1:2020-12 Wyroby i materialy budowlane, Wyroby i materialy konstrukcyjne, Meble Emisja formaldehydu w warunkach dynamicznych (duza i mala komora)\nZakres:\nZakres (0,005 – 0,600) mg/m3\nZakres (0,004 – 0,483) ppm\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) PN-EN 16516+A1:2020-12","categories":["materials","environment","construction"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Building products and materials, Structural products and materials, Furniture Formaldehyde emission under dynamic conditions (large and small chamber) High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Range Range PN-EN 16516+A1:2020-12","parameters_zh":[{"name":"范围","range":"(0,005 – 0,600) mg/m3"},{"name":"范围","range":"(0,004 – 0,483) ppm"}],"search_zh":"建筑制品与材料、结构制品与材料、家具 动态条件下的甲醛释放量（大舱与小舱法） 高效液相色谱-分光光度检测法（HPLC-UV） 范围 范围 PN-EN 16516+A1:2020-12","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）","methodology_zh":"动态条件下的甲醛释放量（大舱与小舱法）","test_object_zh":"建筑制品与材料、结构制品与材料、家具"},{"_id":"6a5dc9c5f1c10c8ce82602c7","lab_id":"69ad52a3de79e566650fb961","country":"PL","accr_number":"AB 1769","accr_body":"PCA","test_object":"Wyroby i materiały budowlane, Wyroby i materiały konstrukcyjne, Meble","test_object_en":"Building products and materials, Structural products and materials, Furniture","methodology":"Emisja formaldehydu w warunkach dynamicznych (duża i mała komora)","methodology_en":"Formaldehyde emission under dynamic conditions (large and small chamber)","parameters":[{"name":"Zakres","range":"(0,003 – 0,349) mg/m3"},{"name":"Zakres","range":"(0,002 – 0,284) ppm"}],"parameters_en":[{"name":"Range","range":"(0,003 – 0,349) mg/m3"},{"name":"Range","range":"(0,002 – 0,284) ppm"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Emisja formaldehydu w warunkach dynamicznych (duża i mała komora)\nZakres:\nZakres (0,003 – 0,349) mg/m3\nZakres (0,002 – 0,284) ppm\nMetoda spektrofotometryczna","reference":"PN-EN 717-1:2006","norm_bases":["PN-EN 717-1:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i materiały budowlane, Wyroby i materiały konstrukcyjne, Meble Emisja formaldehydu w warunkach dynamicznych (duża i mała komora)\nZakres:\nZakres (0,003 – 0,349) mg/m3\nZakres (0,002 – 0,284) ppm\nMetoda spektrofotometryczna PN-EN 717-1:2006 Wyroby i materialy budowlane, Wyroby i materialy konstrukcyjne, Meble Emisja formaldehydu w warunkach dynamicznych (duza i mala komora)\nZakres:\nZakres (0,003 – 0,349) mg/m3\nZakres (0,002 – 0,284) ppm\nMetoda spektrofotometryczna PN-EN 717-1:2006","categories":["materials","environment","construction"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Building products and materials, Structural products and materials, Furniture Formaldehyde emission under dynamic conditions (large and small chamber) Spectrophotometric method Range Range PN-EN 717-1:2006","parameters_zh":[{"name":"范围","range":"(0,003 – 0,349) mg/m3"},{"name":"范围","range":"(0,002 – 0,284) ppm"}],"search_zh":"建筑制品与材料、结构制品与材料、家具 动态条件下的甲醛释放量（大舱与小舱法） 分光光度法 范围 范围 PN-EN 717-1:2006","technique_zh":"分光光度法","methodology_zh":"动态条件下的甲醛释放量（大舱与小舱法）","test_object_zh":"建筑制品与材料、结构制品与材料、家具"},{"_id":"6a5dc9c5f1c10c8ce82602c8","lab_id":"69ad52a3de79e566650fb961","country":"PL","accr_number":"AB 1769","accr_body":"PCA","test_object":"Wyroby i materiały budowlane, Wyroby i materiały konstrukcyjne, Meble","test_object_en":"Building products and materials, Structural products and materials, Furniture","methodology":"Emisja formaldehydu w warunkach dynamicznych (mała komora)","methodology_en":"Formaldehyde emission under dynamic conditions (small chamber)","parameters":[{"name":"Zakres","range":"(0,003 - 0,349) mg/m3"},{"name":"Zakres","range":"(0,002 - 0,284) ppm"},{"name":"Formaldehyde emission in dynamic ASTM D6007-14 conditions (small"}],"parameters_en":[{"name":"Range","range":"(0,003 - 0,349) mg/m3"},{"name":"Range","range":"(0,002 - 0,284) ppm"},{"name":"Formaldehyde emission in dynamic ASTM D6007-14 conditions (small"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Emisja formaldehydu w warunkach dynamicznych (mała komora)\nZakres:\nZakres (0,003 - 0,349) mg/m3\nZakres (0,002 - 0,284) ppm\nFormaldehyde emission in dynamic ASTM D6007-14 conditions (small\nMetoda spektrofotometryczna","reference":"ASTM D6007-14","norm_bases":["ASTM D6007-14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i materiały budowlane, Wyroby i materiały konstrukcyjne, Meble Emisja formaldehydu w warunkach dynamicznych (mała komora)\nZakres:\nZakres (0,003 - 0,349) mg/m3\nZakres (0,002 - 0,284) ppm\nFormaldehyde emission in dynamic ASTM D6007-14 conditions (small\nMetoda spektrofotometryczna ASTM D6007-14 Wyroby i materialy budowlane, Wyroby i materialy konstrukcyjne, Meble Emisja formaldehydu w warunkach dynamicznych (mala komora)\nZakres:\nZakres (0,003 - 0,349) mg/m3\nZakres (0,002 - 0,284) ppm\nFormaldehyde emission in dynamic ASTM D6007-14 conditions (small\nMetoda spektrofotometryczna ASTM D6007-14","categories":["materials","environment","construction"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Building products and materials, Structural products and materials, Furniture Formaldehyde emission under dynamic conditions (small chamber) Spectrophotometric method Range Range Formaldehyde emission in dynamic ASTM D6007-14 conditions (small ASTM D6007-14","parameters_zh":[{"name":"范围","range":"(0,003 - 0,349) mg/m3"},{"name":"范围","range":"(0,002 - 0,284) ppm"},{"name":"Formaldehyde emission in dynamic ASTM D6007-14 conditions (small"}],"search_zh":"建筑制品与材料、结构制品与材料、家具 动态条件下的甲醛释放量（小舱法） 分光光度法 范围 范围 ASTM D6007-14","technique_zh":"分光光度法","methodology_zh":"动态条件下的甲醛释放量（小舱法）","test_object_zh":"建筑制品与材料、结构制品与材料、家具"}],"has_pdf":true}