{"lab":{"_id":"69ad52a3de79e566650fb95f","accr_number":"AB 1768","country":"PL","accr_body":"PCA","address":"plac T. Kościuszki 11, 41-902 Bytom, LABORATORIUM, ul. gen. W. Sikorskiego 5a, 41-922 Radzionków","categories":["water"],"city":"Radzionków","imported_at":"2026-03-08T10:42:43.265Z","methods_count":26,"name":"BYTOMSKIE WODOCIĄGI Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1768.pdf"],"scope_summary":"","search_text":"bytomskie wodociągi sp. z o.o. plac t. kościuszki 11, 41-902 bytom, laboratorium, ul. gen. w. sikorskiego 5a, 41-922 radzionków water other","status":"active","updated_at":"2026-03-08T14:50:53.724Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:53.724Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201768,podmiot.html","fields_of_testing":[{"codes":"C/28/P, C/30/P, C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków, osadów","en":"Chemical tests and sampling of water, sewage, sediments"},{"codes":"N/28/P, N/30/P, N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków, osadów","en":"Tests of physical properties and sampling of water, sewage, sediments"}],"issue":{"no":"8","date":"12.12.2025"},"parse_date":"2026-07-20T07:09:28.965Z","parse_source":"script-pdfplumber","map_coord":[50.400272,18.902625],"map_geo":"nominatim-city","has_en":true,"category_counts":{"water":26},"category_scores":{"water":26},"has_zh":true},"methods":[{"_id":"6a5dc9a8f1c10c8ce8259dd7","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura pobranej próbki ścieków"},{"name":"Zakres","range":"(1,0 – 40,0) °C"}],"parameters_en":[{"name":"Temperature of the collected wastewater sample"},{"name":"Range","range":"(1,0 – 40,0) °C"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"technique_en":"Manual method; Automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (1,0 – 40,0) °C\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (1,0 – 40,0) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow\nZakres (1,0 – 40,0) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Temperature of the collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采废水样品的温度"},{"name":"范围","range":"(1,0 – 40,0) °C"}],"search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a5dc9a8f1c10c8ce8259dd8","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Wody opadowe, wody roztopowe","test_object_en":"Rainwater, snowmelt water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody opadowe, wody roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11 Wody opadowe, wody roztopowe Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rainwater, snowmelt water Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11","methodology_zh":"化学与物理检测用样品采集","search_zh":"雨水、融雪水 化学与物理检测用样品采集 手工法 PN-ISO 5667-10:2021-11","test_object_zh":"雨水、融雪水","technique_zh":"手工法"},{"_id":"6a5dc9a8f1c10c8ce8259dd9","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody /pobranej próbki wody","methodology_en":"Sampling for chemical and physical testing Temperature of water /of the water sample taken","parameters":[{"name":"Zakres","range":"(1,0 – 40,0) °C"}],"parameters_en":[{"name":"Range","range":"(1,0 – 40,0) °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody /pobranej próbki wody\nZakres (1,0 – 40,0) °C","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5, 7.6, 8.2 | PN-77/C-04584","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5, 7.6, 8.2","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody /pobranej próbki wody\nZakres (1,0 – 40,0) °C PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5, 7.6, 8.2 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura wody /pobranej probki wody\nZakres (1,0 – 40,0) °C PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt. 7.5, 7.6, 8.2 | PN-77/C-04584","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for chemical and physical testing Temperature of water /of the water sample taken Range PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5, 7.6, 8.2 | PN-77/C-04584","parameters_zh":[{"name":"范围","range":"(1,0 – 40,0) °C"}],"search_zh":"水 范围 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5, 7.6, 8.2 | PN-77/C-04584","test_object_zh":"水"},{"_id":"6a5dc9a8f1c10c8ce8259dda","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a5dc9a8f1c10c8ce8259ddb","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr","methodology_en":"Chemical oxygen demand − COD-Cr","parameters":[{"name":"Zakres","range":"(10,0 – 10000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(10,0 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (10,0 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (10,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (10,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Chemical oxygen demand − COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(10,0 – 10000) mg/l O2"}],"search_zh":"水、废水 化学需氧量 － COD-Cr 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量 － COD-Cr"},{"_id":"6a5dc9a8f1c10c8ce8259ddc","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu − BZT5","methodology_en":"Biochemical oxygen demand − BOD5","parameters":[{"name":"Zakres","range":"(0,50 – 6,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,50 – 6,0) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda miareczkowa","reference":"P N-EN 1899-2:2002","norm_bases":["P N-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda miareczkowa P N-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda miareczkowa P N-EN 1899-2:2002","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical oxygen demand − BOD5 Titrimetric method Range P N-EN 1899-2:2002","parameters_zh":[{"name":"范围","range":"(0,50 – 6,0) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 滴定法 范围 P N-EN 1899-2:2002","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9a8f1c10c8ce8259ddd","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu − BZT5","methodology_en":"Biochemical oxygen demand − BOD5","parameters":[{"name":"Zakres","range":"(3 – 3500) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(3 – 3500) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (3 – 3500) mg/l O2\nMetoda miareczkowa","reference":"P N-EN ISO 5815-1:2019-12","norm_bases":["P N-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (3 – 3500) mg/l O2\nMetoda miareczkowa P N-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (3 – 3500) mg/l O2\nMetoda miareczkowa P N-EN ISO 5815-1:2019-12","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical oxygen demand − BOD5 Titrimetric method Range P N-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(3 – 3500) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 滴定法 范围 P N-EN ISO 5815-1:2019-12","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9a8f1c10c8ce8259dde","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,04 – 40,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,04 – 40,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,04 – 40,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,04 – 40,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,04 – 40,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 40,0) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9a8f1c10c8ce8259ddf","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (1,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (1,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie azotu amonowego\nZakres (1,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/l"}],"search_zh":"水、废水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a5dc9a8f1c10c8ce8259de0","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,010 – 10,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,010 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,010 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 10,0) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9a8f1c10c8ce8259de1","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,04 – 50,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,04 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres (0,04 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu azotanowego\nZakres (0,04 – 50,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, scieki Stezenie azotu azotanowego\nZakres (0,04 – 50,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576.08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 50,0) mg/l"}],"search_zh":"水、废水 硝态氮浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9a8f1c10c8ce8259de2","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (1,0 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (1,0 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a5dc9a8f1c10c8ce8259de3","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576.14","norm_bases":["PN-73/C-04576.14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576.14 Woda, scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576.14","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total nitrogen concentration (calculated) PN-73/C-04576.14","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PN-73/C-04576.14","test_object_zh":"水、废水"},{"_id":"6a5dc9a8f1c10c8ce8259de4","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie ortofosforanów","methodology_en":"Orthophosphate concentration","parameters":[{"name":"Zakres","range":"(0,040 – 20,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,040 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów\nZakres (0,040 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie ortofosforanów\nZakres (0,040 – 20,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010 Woda, scieki Stezenie ortofosforanow\nZakres (0,040 – 20,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,040 – 20,0) mg/l"}],"search_zh":"水、废水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt. 4 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a5dc9a8f1c10c8ce8259de5","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,040 – 50,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,040 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,040 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,040 – 50,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,040 – 50,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 50,0) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9a8f1c10c8ce8259de6","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(40,0 – 150) mg/l"}],"parameters_en":[{"name":"Range","range":"(40,0 – 150) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (40,0 – 150) mg/l\nMetoda spektrofotometryczna","reference":"PB-01 wydanie 02 z dnia 25.07.2025 | na podstawie testu kuwetowego Hach nr LCK 153","norm_bases":["PB-01 wydanie 02 z dnia 25.07.2025","na podstawie testu kuwetowego Hach nr LCK 153"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (40,0 – 150) mg/l\nMetoda spektrofotometryczna PB-01 wydanie 02 z dnia 25.07.2025 | na podstawie testu kuwetowego Hach nr LCK 153 Woda, scieki Stezenie siarczanow\nZakres (40,0 – 150) mg/l\nMetoda spektrofotometryczna PB-01 wydanie 02 z dnia 25.07.2025 | na podstawie testu kuwetowego Hach nr LCK 153","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Sulfate concentration Spectrophotometric method Range PB-01 wydanie 02 z dnia 25.07.2025 | na podstawie testu kuwetowego Hach nr LCK 153","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(40,0 – 150) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 分光光度法 范围 PB-01 wydanie 02 z dnia 25.07.2025 | na podstawie testu kuwetowego Hach nr LCK 153","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9a8f1c10c8ce8259de7","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(150 – 900) mg/l"}],"parameters_en":[{"name":"Range","range":"(150 – 900) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (150 – 900) mg/l\nMetoda spektrofotometryczna","reference":"PB-02 wydanie 02 z dnia 25.07.2025 | na podstawie testu kuwetowego Hach nr LCK 353","norm_bases":["PB-02 wydanie 02 z dnia 25.07.2025","na podstawie testu kuwetowego Hach nr LCK 353"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (150 – 900) mg/l\nMetoda spektrofotometryczna PB-02 wydanie 02 z dnia 25.07.2025 | na podstawie testu kuwetowego Hach nr LCK 353 Woda, scieki Stezenie siarczanow\nZakres (150 – 900) mg/l\nMetoda spektrofotometryczna PB-02 wydanie 02 z dnia 25.07.2025 | na podstawie testu kuwetowego Hach nr LCK 353","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Sulfate concentration Spectrophotometric method Range PB-02 wydanie 02 z dnia 25.07.2025 | na podstawie testu kuwetowego Hach nr LCK 353","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(150 – 900) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 分光光度法 范围 PB-02 wydanie 02 z dnia 25.07.2025 | na podstawie testu kuwetowego Hach nr LCK 353","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9a8f1c10c8ce8259de8","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/l"}],"search_zh":"水、废水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a5dc9a8f1c10c8ce8259de9","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Woda, ścieki (w tym, wody opadowe, wody roztopowe)","test_object_en":"Water, wastewater (including rainwater, snowmelt water)","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki (w tym, wody opadowe, wody roztopowe) Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki (w tym, wody opadowe, wody roztopowe) Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater (including rainwater, snowmelt water) Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法"},{"_id":"6a5dc9a8f1c10c8ce8259dea","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Pobieranie próbek do badań chemicznych, fizycznych","methodology_en":"Sampling for chemical, physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych, fizycznych PN-EN ISO 5667-13:2011 Osady sciekowe Pobieranie probek do badan chemicznych, fizycznych PN-EN ISO 5667-13:2011","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Sampling for chemical, physical testing PN-EN ISO 5667-13:2011","search_zh":"污泥 用于化学、物理检验的采样 PN-EN ISO 5667-13:2011","test_object_zh":"污泥","methodology_zh":"用于化学、物理检验的采样"},{"_id":"6a5dc9a8f1c10c8ce8259deb","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"pH – w H2O","methodology_en":"pH – in H2O","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda: potencjometryczna","techniques":["Metoda: potencjometryczna"],"technique_en":"Method: potentiometric","computed":[],"computed_en":[],"activity":"pH – w H2O\nZakres 2,0 – 12,0\nMetoda: potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe pH – w H2O\nZakres 2,0 – 12,0\nMetoda: potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH – w H2O\nZakres 2,0 – 12,0\nMetoda: potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge pH – in H2O Method: potentiometric Range PN-EN ISO 10390:2022-09","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"污泥 pH — 于 H2O 中 范围 PN-EN ISO 10390:2022-09","test_object_zh":"污泥","methodology_zh":"pH — 于 H2O 中"},{"_id":"6a5dc9a8f1c10c8ce8259dec","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość suchej pozostałości","methodology_en":"Dry residue content","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"},{"name":"Zawartość wody (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"},{"name":"Water content (calculated)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość suchej pozostałości\nZakres:\nZakres (0,5 – 99,5) %\nZawartość wody (z obliczeń)\nMetoda wagowa","reference":"PN-EN 15934:2013-02","norm_bases":["PN-EN 15934:2013-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość suchej pozostałości\nZakres:\nZakres (0,5 – 99,5) %\nZawartość wody (z obliczeń)\nMetoda wagowa PN-EN 15934:2013-02 Osady sciekowe Zawartosc suchej pozostalosci\nZakres:\nZakres (0,5 – 99,5) %\nZawartosc wody (z obliczen)\nMetoda wagowa PN-EN 15934:2013-02","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Dry residue content Gravimetric method Range Water content (calculated) PN-EN 15934:2013-02","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"},{"name":"水分含量（计算值）"}],"search_zh":"污泥 重量法 范围 水分含量（计算值） PN-EN 15934:2013-02","technique_zh":"重量法","test_object_zh":"污泥"},{"_id":"6a5dc9a8f1c10c8ce8259ded","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Straty podczas prażenia / pozostałość po prażeniu","methodology_en":"Loss on ignition / residue on ignition","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Straty podczas prażenia / pozostałość po prażeniu\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01 z wyłączeniem pkt 7.4, 8.2","norm_bases":["PN-EN 15935:2022-01 z wyłączeniem pkt 7.4, 8.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Straty podczas prażenia / pozostałość po prażeniu\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15935:2022-01 z wyłączeniem pkt 7.4, 8.2 Osady sciekowe Straty podczas prazenia / pozostalosc po prazeniu\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15935:2022-01 z wylaczeniem pkt 7.4, 8.2","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Loss on ignition / residue on ignition Gravimetric method Range PN-EN 15935:2022-01 z wyłączeniem pkt 7.4, 8.2","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"污泥 重量法 范围 PN-EN 15935:2022-01 z wyłączeniem pkt 7.4, 8.2","technique_zh":"重量法","test_object_zh":"污泥"},{"_id":"6a5dc9a8f1c10c8ce8259dee","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość azotu amonowego","methodology_en":"Ammonium nitrogen content","parameters":[{"name":"Zakres","range":"(0,50 – 10,0) %"}],"parameters_en":[{"name":"Range","range":"(0,50 – 10,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość azotu amonowego\nZakres (0,50 – 10,0) %\nMetoda miareczkowa","reference":"PN-EN 14671:2007 | PN-ISO 5664:2002","norm_bases":["PN-EN 14671:2007","PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość azotu amonowego\nZakres (0,50 – 10,0) %\nMetoda miareczkowa PN-EN 14671:2007 | PN-ISO 5664:2002 Osady sciekowe Zawartosc azotu amonowego\nZakres (0,50 – 10,0) %\nMetoda miareczkowa PN-EN 14671:2007 | PN-ISO 5664:2002","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Ammonium nitrogen content Titrimetric method Range PN-EN 14671:2007 | PN-ISO 5664:2002","parameters_zh":[{"name":"范围","range":"(0,50 – 10,0) %"}],"search_zh":"污泥 氨氮含量 滴定法 范围 PN-EN 14671:2007 | PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"氨氮含量"},{"_id":"6a5dc9a8f1c10c8ce8259def","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen content","parameters":[{"name":"Zakres","range":"(0,50 – 10,0) %"}],"parameters_en":[{"name":"Range","range":"(0,50 – 10,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość azotu Kjeldahla\nZakres (0,50 – 10,0) %\nMetoda miareczkowa","reference":"PN-EN 16169:2012","norm_bases":["PN-EN 16169:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość azotu Kjeldahla\nZakres (0,50 – 10,0) %\nMetoda miareczkowa PN-EN 16169:2012 Osady sciekowe Zawartosc azotu Kjeldahla\nZakres (0,50 – 10,0) %\nMetoda miareczkowa PN-EN 16169:2012","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Kjeldahl nitrogen content Titrimetric method Range PN-EN 16169:2012","parameters_zh":[{"name":"范围","range":"(0,50 – 10,0) %"}],"search_zh":"污泥 凯氏氮含量 滴定法 范围 PN-EN 16169:2012","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"凯氏氮含量"},{"_id":"6a5dc9a8f1c10c8ce8259df0","lab_id":"69ad52a3de79e566650fb95f","country":"PL","accr_number":"AB 1768","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość fosforu ogólnego","methodology_en":"Total phosphorus content","parameters":[{"name":"Zakres","range":"(0,50 – 5,0) %"}],"parameters_en":[{"name":"Range","range":"(0,50 – 5,0) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Zawartość fosforu ogólnego\nZakres (0,50 – 5,0) %\nMetoda spektrofotometryczna","reference":"PN-EN 14672:2006 | PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN 14672:2006","PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość fosforu ogólnego\nZakres (0,50 – 5,0) %\nMetoda spektrofotometryczna PN-EN 14672:2006 | PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010 Osady sciekowe Zawartosc fosforu ogolnego\nZakres (0,50 – 5,0) %\nMetoda spektrofotometryczna PN-EN 14672:2006 | PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Total phosphorus content Spectrophotometric method Range PN-EN 14672:2006 | PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,50 – 5,0) %"}],"search_zh":"污泥 总磷含量 分光光度法 范围 PN-EN 14672:2006 | PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污泥","methodology_zh":"总磷含量"}],"has_pdf":true}