{"lab":{"_id":"69ad52a3de79e566650fb94d","accr_number":"AB 1759","country":"PL","accr_body":"PCA","address":"LABORATORIUM CHEMICZNE, ul. Opata Hackiego 14, 81-213 Gdynia","categories":["water","environment"],"city":"Gdynia","imported_at":"2026-03-08T10:42:43.265Z","methods_count":20,"name":"OKRĘGOWE PRZEDSIĘBIORSTWO ENERGETYKI CIEPLNEJ Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1759.pdf"],"scope_summary":"","search_text":"okręgowe przedsiębiorstwo energetyki cieplnej sp. z o.o. laboratorium chemiczne, ul. opata hackiego 14, 81-213 gdynia water pharma electronics other environment","status":"active","updated_at":"2026-03-08T14:50:52.764Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:52.764Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201759,podmiot.html","fields_of_testing":[{"codes":"C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"C/36/P","pl":"Badania chemiczne i pobierania próbek gazów odlotowych","en":"Chemical tests and sampling of waste gases"},{"codes":"G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – gazy – gazy odlotowe","en":"Tests concerning environmental engineering (environmental and climatic) – gases - waste gases"},{"codes":"N/28","pl":"Badania właściwości fizycznych wody","en":"Tests of physical properties of water"},{"codes":"N/36/P","pl":"Badania właściwości fizycznych i pobieranie próbek gazów odlotowych","en":"Tests of physical properties and sampling of waste gases"}],"issue":{"no":"6","date":"04.11.2025"},"parse_date":"2026-07-20T07:09:28.735Z","parse_source":"script-pdfplumber","map_coord":[54.536682,18.487398],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":9,"other":7,"environment":4},"category_scores":{"water":4.05,"other":2.45,"environment":0.8},"has_zh":true},"methods":[{"_id":"6a5dc9a8f1c10c8ce8259d03","lab_id":"69ad52a3de79e566650fb94d","country":"PL","accr_number":"AB 1759","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水"},{"_id":"6a5dc9a8f1c10c8ce8259d04","lab_id":"69ad52a3de79e566650fb94d","country":"PL","accr_number":"AB 1759","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(25 – 1410) μS/cm"}],"parameters_en":[{"name":"Range","range":"(25 – 1410) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (25 – 1410) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Przewodność elektryczna właściwa\nZakres (25 – 1410) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa\nZakres (25 – 1410) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(25 – 1410) μS/cm"}],"search_zh":"水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水"},{"_id":"6a5dc9a8f1c10c8ce8259d05","lab_id":"69ad52a3de79e566650fb94d","country":"PL","accr_number":"AB 1759","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(0,10 – 2,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,10 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"I-10.03.04 wydanie 3 z dnia 11.10.2021 r. | na podstawie testu Nanocolor 1-36","norm_bases":["I-10.03.04 wydanie 3 z dnia 11.10.2021 r.","na podstawie testu Nanocolor 1-36"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie żelaza ogólnego\nZakres (0,10 – 2,0) mg/l\nMetoda spektrofotometryczna I-10.03.04 wydanie 3 z dnia 11.10.2021 r. | na podstawie testu Nanocolor 1-36 Woda Stezenie zelaza ogolnego\nZakres (0,10 – 2,0) mg/l\nMetoda spektrofotometryczna I-10.03.04 wydanie 3 z dnia 11.10.2021 r. | na podstawie testu Nanocolor 1-36","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total iron concentration Spectrophotometric method Range I-10.03.04 wydanie 3 z dnia 11.10.2021 r. | na podstawie testu Nanocolor 1-36","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 2,0) mg/l"}],"search_zh":"水 总铁浓度 分光光度法 范围 I-10.03.04 wydanie 3 z dnia 11.10.2021 r. | na podstawie testu Nanocolor 1-36","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a5dc9a8f1c10c8ce8259d06","lab_id":"69ad52a3de79e566650fb94d","country":"PL","accr_number":"AB 1759","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(0,5 – 50,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,5 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (0,5 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"I-10.03.03 wydanie 3 z dnia 11.10.2021 r. | na podstawie testu Nanocolor 0-21","norm_bases":["I-10.03.03 wydanie 3 z dnia 11.10.2021 r.","na podstawie testu Nanocolor 0-21"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chlorków\nZakres (0,5 – 50,0) mg/l\nMetoda spektrofotometryczna I-10.03.03 wydanie 3 z dnia 11.10.2021 r. | na podstawie testu Nanocolor 0-21 Woda Stezenie chlorkow\nZakres (0,5 – 50,0) mg/l\nMetoda spektrofotometryczna I-10.03.03 wydanie 3 z dnia 11.10.2021 r. | na podstawie testu Nanocolor 0-21","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Chloride concentration Spectrophotometric method Range I-10.03.03 wydanie 3 z dnia 11.10.2021 r. | na podstawie testu Nanocolor 0-21","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(0,5 – 50,0) mg/l"}],"search_zh":"水 氯化物浓度 分光光度法 范围 I-10.03.03 wydanie 3 z dnia 11.10.2021 r. | na podstawie testu Nanocolor 0-21","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a5dc9a8f1c10c8ce8259d07","lab_id":"69ad52a3de79e566650fb94d","country":"PL","accr_number":"AB 1759","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5 – 150) mg/l"}],"parameters_en":[{"name":"Range","range":"(5 – 150) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5 – 150) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chlorków\nZakres (5 – 150) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda Stezenie chlorkow\nZakres (5 – 150) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 – 150) mg/l"}],"search_zh":"水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a5dc9a8f1c10c8ce8259d08","lab_id":"69ad52a3de79e566650fb94d","country":"PL","accr_number":"AB 1759","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Twardość resztkowa","methodology_en":"Residual hardness","parameters":[{"name":"Zakres","range":"(0,025 – 0,150) mmol/l"}],"parameters_en":[{"name":"Range","range":"(0,025 – 0,150) mmol/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Twardość resztkowa\nZakres (0,025 – 0,150) mmol/l\nMetoda spektrofotometryczna","reference":"I-10.03.02 wydanie 4 z dnia 26.09.2025 r. | na podstawie testu Nanoclor 0-84","norm_bases":["I-10.03.02 wydanie 4 z dnia 26.09.2025 r.","na podstawie testu Nanoclor 0-84"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Twardość resztkowa\nZakres (0,025 – 0,150) mmol/l\nMetoda spektrofotometryczna I-10.03.02 wydanie 4 z dnia 26.09.2025 r. | na podstawie testu Nanoclor 0-84 Woda Twardosc resztkowa\nZakres (0,025 – 0,150) mmol/l\nMetoda spektrofotometryczna I-10.03.02 wydanie 4 z dnia 26.09.2025 r. | na podstawie testu Nanoclor 0-84","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Residual hardness Spectrophotometric method Range I-10.03.02 wydanie 4 z dnia 26.09.2025 r. | na podstawie testu Nanoclor 0-84","parameters_zh":[{"name":"范围","range":"(0,025 – 0,150) mmol/l"}],"search_zh":"水 分光光度法 范围 I-10.03.02 wydanie 4 z dnia 26.09.2025 r. | na podstawie testu Nanoclor 0-84","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a5dc9a8f1c10c8ce8259d09","lab_id":"69ad52a3de79e566650fb94d","country":"PL","accr_number":"AB 1759","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Twardość ogólna","methodology_en":"Total hardness","parameters":[{"name":"Zakres","range":"(0,15 – 1,8) mmol/l"}],"parameters_en":[{"name":"Range","range":"(0,15 – 1,8) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Twardość ogólna\nZakres (0,15 – 1,8) mmol/l\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Twardość ogólna\nZakres (0,15 – 1,8) mmol/l\nMetoda miareczkowa PN-ISO 6059:1999 Woda Twardosc ogolna\nZakres (0,15 – 1,8) mmol/l\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total hardness Titrimetric method Range PN-ISO 6059:1999","parameters_zh":[{"name":"范围","range":"(0,15 – 1,8) mmol/l"}],"search_zh":"水 总硬度 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水","methodology_zh":"总硬度"},{"_id":"6a5dc9a8f1c10c8ce8259d0a","lab_id":"69ad52a3de79e566650fb94d","country":"PL","accr_number":"AB 1759","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Zasadowość wobec fenoloftaleiny","methodology_en":"Alkalinity to phenolphthalein","parameters":[{"name":"Zakres","range":"(0,10 – 5,00) mmol/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 5,00) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zasadowość wobec fenoloftaleiny\nZakres (0,10 – 5,00) mmol/l\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001 +Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001 +Ap1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Zasadowość wobec fenoloftaleiny\nZakres (0,10 – 5,00) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001 +Ap1:2004 Woda Zasadowosc wobec fenoloftaleiny\nZakres (0,10 – 5,00) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001 +Ap1:2004","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Alkalinity to phenolphthalein Titrimetric method Range PN-EN ISO 9963-1:2001 +Ap1:2004","parameters_zh":[{"name":"范围","range":"(0,10 – 5,00) mmol/l"}],"search_zh":"水 滴定法 范围 PN-EN ISO 9963-1:2001 +Ap1:2004","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a5dc9a8f1c10c8ce8259d0b","lab_id":"69ad52a3de79e566650fb94d","country":"PL","accr_number":"AB 1759","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Zasadowość ogólna","methodology_en":"Total alkalinity","parameters":[{"name":"Zakres","range":"(0,10 – 5,00) mmol/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 5,00) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zasadowość ogólna\nZakres (0,10 – 5,00) mmol/l\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001 +Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001 +Ap1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Zasadowość ogólna\nZakres (0,10 – 5,00) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001 +Ap1:2004 Woda Zasadowosc ogolna\nZakres (0,10 – 5,00) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001 +Ap1:2004","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total alkalinity Titrimetric method Range PN-EN ISO 9963-1:2001 +Ap1:2004","parameters_zh":[{"name":"范围","range":"(0,10 – 5,00) mmol/l"}],"search_zh":"水 总碱度 滴定法 范围 PN-EN ISO 9963-1:2001 +Ap1:2004","technique_zh":"滴定法","test_object_zh":"水","methodology_zh":"总碱度"},{"_id":"6a5dc9a8f1c10c8ce8259d0c","lab_id":"69ad52a3de79e566650fb94d","country":"PL","accr_number":"AB 1759","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa","parameters":[],"parameters_en":[],"technique":"Metoda spiętrzania","techniques":["Metoda spiętrzania"],"technique_en":"Stagnation pressure method","computed":[],"computed_en":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nMetoda spiętrzania","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nMetoda spiętrzania PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa\nMetoda spietrzania PN-Z-04030-7:1994","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Stagnation pressure method PN-Z-04030-7:1994","search_zh":"废气 动压 > 10 Pa 时的气体体积流量 皮托管法 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"动压 > 10 Pa 时的气体体积流量","technique_zh":"皮托管法"},{"_id":"6a5dc9a8f1c10c8ce8259d0d","lab_id":"69ad52a3de79e566650fb94d","country":"PL","accr_number":"AB 1759","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-Z-04030-7:1994","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of dust concentration PN-Z-04030-7:1994","search_zh":"废气 粉尘浓度测定采样 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5dc9a8f1c10c8ce8259d0e","lab_id":"69ad52a3de79e566650fb94d","country":"PL","accr_number":"AB 1759","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(0,001 – 0,5) g/m3"}],"parameters_en":[{"name":"Range","range":"(0,001 – 0,5) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (0,001 – 0,5) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,001 – 0,5) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Gazy odlotowe Stezenie pylu\nZakres (0,001 – 0,5) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust concentration Gravimetric method Range PN-Z-04030-7:1994","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 0,5) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a5dc9a8f1c10c8ce8259d0f","lab_id":"69ad52a3de79e566650fb94d","country":"PL","accr_number":"AB 1759","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja pylu (z obliczen) PN-Z-04030-7:1994","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust emission (calculated) PN-Z-04030-7:1994","search_zh":"废气 粉尘排放量（计算值） PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5dc9a8f1c10c8ce8259d10","lab_id":"69ad52a3de79e566650fb94d","country":"PL","accr_number":"AB 1759","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku azotu, tlenków azotu","methodology_en":"Concentration of nitrogen monoxide, nitrogen oxides","parameters":[{"name":"NO","range":"(3,00 – 1600,00) mg/m3"},{"name":"NOx","range":"(4,00 – 2500,00) mg/m3"}],"parameters_en":[{"name":"NO","range":"(3,00 – 1600,00) mg/m3"},{"name":"NOx","range":"(4,00 – 2500,00) mg/m3"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"technique_en":"Chemiluminescence method","computed":[],"computed_en":[],"activity":"Stężenie tlenku azotu, tlenków azotu\nZakres:\nNO (3,00 – 1600,00) mg/m3\nNOx (4,00 – 2500,00) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-ISO 10396:2001 | PN-EN 14792:2017-04","norm_bases":["PN-ISO 10396:2001","PN-EN 14792:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku azotu, tlenków azotu\nZakres:\nNO (3,00 – 1600,00) mg/m3\nNOx (4,00 – 2500,00) mg/m3\nMetoda chemiluminescencyjna PN-ISO 10396:2001 | PN-EN 14792:2017-04 Gazy odlotowe Stezenie tlenku azotu, tlenkow azotu\nZakres:\nNO (3,00 – 1600,00) mg/m3\nNOx (4,00 – 2500,00) mg/m3\nMetoda chemiluminescencyjna PN-ISO 10396:2001 | PN-EN 14792:2017-04","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration of nitrogen monoxide, nitrogen oxides Chemiluminescence method NO NOx PN-ISO 10396:2001 | PN-EN 14792:2017-04","search_zh":"废气 一氧化氮、氮氧化物浓度 化学发光法 NO NOx PN-ISO 10396:2001 | PN-EN 14792:2017-04","test_object_zh":"废气","parameters_zh":[{"name":"NO","range":"(3,00 – 1600,00) mg/m3"},{"name":"NOx","range":"(4,00 – 2500,00) mg/m3"}],"technique_zh":"化学发光法","methodology_zh":"一氧化氮、氮氧化物浓度"},{"_id":"6a5dc9a8f1c10c8ce8259d11","lab_id":"69ad52a3de79e566650fb94d","country":"PL","accr_number":"AB 1759","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","methodology_en":"NO, NOx emission (NO and NO2 calculated as NO2) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","reference":"PN-ISO 10396:2001 | PN-EN 14792:2017-04","norm_bases":["PN-ISO 10396:2001","PN-EN 14792:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń) PN-ISO 10396:2001 | PN-EN 14792:2017-04 Gazy odlotowe Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczen) PN-ISO 10396:2001 | PN-EN 14792:2017-04","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases NO, NOx emission (NO and NO2 calculated as NO2) (calculated) PN-ISO 10396:2001 | PN-EN 14792:2017-04","search_zh":"废气 NO、NOx（NO 与 NO2 以 NO2 计）排放（由计算得出） PN-ISO 10396:2001 | PN-EN 14792:2017-04","test_object_zh":"废气","methodology_zh":"NO、NOx（NO 与 NO2 以 NO2 计）排放（由计算得出）"},{"_id":"6a5dc9a8f1c10c8ce8259d12","lab_id":"69ad52a3de79e566650fb94d","country":"PL","accr_number":"AB 1759","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie dwutlenku siarki, dwutlenku węgla","methodology_en":"Concentration of sulphur dioxide, carbon dioxide","parameters":[{"name":"SO2","range":"(3,00 – 1800,00) mg/m3"},{"name":"CO2","range":"(0,10 – 22,0) %"}],"parameters_en":[{"name":"SO2","range":"(3,00 – 1800,00) mg/m3"},{"name":"CO2","range":"(0,10 – 22,0) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie dwutlenku siarki, dwutlenku węgla\nZakres:\nSO2 (3,00 – 1800,00) mg/m3\nCO2 (0,10 – 22,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie dwutlenku siarki, dwutlenku węgla\nZakres:\nSO2 (3,00 – 1800,00) mg/m3\nCO2 (0,10 – 22,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 Gazy odlotowe Stezenie dwutlenku siarki, dwutlenku wegla\nZakres:\nSO2 (3,00 – 1800,00) mg/m3\nCO2 (0,10 – 22,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration of sulphur dioxide, carbon dioxide Non-dispersive infrared spectrometry (NDIR) SO2 CO2 PN-ISO 10396:2001","search_zh":"废气 非分散红外光谱法（NDIR） SO2 CO2 PN-ISO 10396:2001","test_object_zh":"废气","parameters_zh":[{"name":"SO2","range":"(3,00 – 1800,00) mg/m3"},{"name":"CO2","range":"(0,10 – 22,0) %"}],"technique_zh":"非分散红外光谱法（NDIR）"},{"_id":"6a5dc9a8f1c10c8ce8259d13","lab_id":"69ad52a3de79e566650fb94d","country":"PL","accr_number":"AB 1759","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja dwutlenku siarki, dwutlenku węgla (z obliczeń)","methodology_en":"Emission of sulphur dioxide, carbon dioxide (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja dwutlenku siarki, dwutlenku węgla (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja dwutlenku siarki, dwutlenku węgla (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja dwutlenku siarki, dwutlenku wegla (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of sulphur dioxide, carbon dioxide (calculated) PN-ISO 10396:2001","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5dc9a8f1c10c8ce8259d14","lab_id":"69ad52a3de79e566650fb94d","country":"PL","accr_number":"AB 1759","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku węgla, CO (2,00 – 1200,00) mg/m3","methodology_en":"Carbon monoxide concentration, CO (2,00 – 1200,00) mg/m3","parameters":[],"parameters_en":[],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla, CO (2,00 – 1200,00) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-ISO 10396:2001 | PN-EN 15058:2017-04","norm_bases":["PN-ISO 10396:2001","PN-EN 15058:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku węgla, CO (2,00 – 1200,00) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 | PN-EN 15058:2017-04 Gazy odlotowe Stezenie tlenku wegla, CO (2,00 – 1200,00) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 | PN-EN 15058:2017-04","categories":["other"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Carbon monoxide concentration, CO (2,00 – 1200,00) mg/m3 Non-dispersive infrared spectrometry (NDIR) PN-ISO 10396:2001 | PN-EN 15058:2017-04","search_zh":"废气 非分散红外光谱法（NDIR） PN-ISO 10396:2001 | PN-EN 15058:2017-04","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）"},{"_id":"6a5dc9a8f1c10c8ce8259d15","lab_id":"69ad52a3de79e566650fb94d","country":"PL","accr_number":"AB 1759","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja tlenku węgla (z obliczeń)","methodology_en":"Carbon monoxide emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja tlenku węgla (z obliczeń)","reference":"PN-ISO 10396:2001 | PN-EN 15058:2017-04","norm_bases":["PN-ISO 10396:2001","PN-EN 15058:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja tlenku węgla (z obliczeń) PN-ISO 10396:2001 | PN-EN 15058:2017-04 Gazy odlotowe Emisja tlenku wegla (z obliczen) PN-ISO 10396:2001 | PN-EN 15058:2017-04","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Carbon monoxide emission (calculated) PN-ISO 10396:2001 | PN-EN 15058:2017-04","search_zh":"废气 一氧化碳排放（由计算得出） PN-ISO 10396:2001 | PN-EN 15058:2017-04","test_object_zh":"废气","methodology_zh":"一氧化碳排放（由计算得出）"},{"_id":"6a5dc9a8f1c10c8ce8259d16","lab_id":"69ad52a3de79e566650fb94d","country":"PL","accr_number":"AB 1759","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenu","methodology_en":"Oxygen concentration","parameters":[{"name":"Zakres","range":"(0,5 – 21,0) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 21,0) %"}],"technique":"Metoda paramagnetyczna","techniques":["Metoda paramagnetyczna"],"technique_en":"Paramagnetic method","computed":[],"computed_en":[],"activity":"Stężenie tlenu\nZakres (0,5 – 21,0) %\nMetoda paramagnetyczna","reference":"PN-ISO 10396:2001 | PN-EN 14789:2017-04","norm_bases":["PN-ISO 10396:2001","PN-EN 14789:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenu\nZakres (0,5 – 21,0) %\nMetoda paramagnetyczna PN-ISO 10396:2001 | PN-EN 14789:2017-04 Gazy odlotowe Stezenie tlenu\nZakres (0,5 – 21,0) %\nMetoda paramagnetyczna PN-ISO 10396:2001 | PN-EN 14789:2017-04","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Oxygen concentration Paramagnetic method Range PN-ISO 10396:2001 | PN-EN 14789:2017-04","parameters_zh":[{"name":"范围","range":"(0,5 – 21,0) %"}],"search_zh":"废气 氧浓度 顺磁法 范围 PN-ISO 10396:2001 | PN-EN 14789:2017-04","test_object_zh":"废气","methodology_zh":"氧浓度","technique_zh":"顺磁法"}],"has_pdf":true}