{"lab":{"_id":"69ad52a3de79e566650fb94b","accr_number":"AB 1758","country":"PL","accr_body":"PCA","address":"SPARK-LAB Sp. z o.o., al. Zwycięstwa 96/98, 81-451 Gdynia","categories":["electronics","pharma","automotive"],"city":"Gdynia","imported_at":"2026-03-08T10:42:43.265Z","methods_count":7,"name":"LABORATORIUM ANALIZ CHEMICZNYCH","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1758.pdf"],"scope_summary":"","search_text":"laboratorium analiz chemicznych spark-lab sp. z o.o., al. zwycięstwa 96/98, 81-451 gdynia other electronics food pharma environment","status":"active","updated_at":"2026-03-08T14:50:52.704Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:52.704Z","location":{"type":"Point","coordinates":[18.5305,54.5189]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201758,podmiot.html","fields_of_testing":[{"codes":"C/1; C/17; C/22; C/24; C/42","pl":"Badania chemiczne produktów rolnych, wyrobów innych, żywności, wyrobów tytoniowych, kosmetyków","en":"Chemical tests of agricultural products, other products, food, tobacco products, cosmetics"},{"codes":"N/17","pl":"Badania fizyczne wyrobów innych","en":"Tests of physical properties of other products"}],"issue":{"no":"6","date":"19.09.2025"},"parse_date":"2026-07-20T07:09:56.897Z","parse_source":"script-pdfplumber","map_coord":[54.494843,18.538421],"map_geo":"nominatim-street","has_en":true,"category_counts":{"electronics":6,"pharma":1,"automotive":1},"category_scores":{"electronics":4.5,"pharma":0.13,"automotive":0.13},"has_zh":true},"methods":[{"_id":"6a5dc9c4f1c10c8ce8260246","lab_id":"69ad52a3de79e566650fb94b","country":"PL","accr_number":"AB 1758","accr_body":"PCA","test_object":"Płyny do uzupełniania papierosów elektronicznych (e-liquid)","test_object_en":"Refill liquids for electronic cigarettes (e-liquid)","methodology":"Zawartość nikotyny","methodology_en":"Nicotine content","parameters":[{"name":"Zakres","range":"(2,77 - 32,92) mg/g"}],"parameters_en":[{"name":"Range","range":"(2,77 - 32,92) mg/g"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Zawartość nikotyny\nZakres (2,77 - 32,92) mg/g\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)","reference":"PN-EN ISO 20714:2022-05","norm_bases":["PN-EN ISO 20714:2022-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyny do uzupełniania papierosów elektronicznych (e-liquid) Zawartość nikotyny\nZakres (2,77 - 32,92) mg/g\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID) PN-EN ISO 20714:2022-05 Plyny do uzupelniania papierosow elektronicznych (e-liquid) Zawartosc nikotyny\nZakres (2,77 - 32,92) mg/g\nMetoda chromatografii gazowej z detekcja plomieniowo - jonizacyjna (GC-FID) PN-EN ISO 20714:2022-05","categories":["electronics"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Refill liquids for electronic cigarettes (e-liquid) Nicotine content Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 20714:2022-05","methodology_zh":"尼古丁含量","parameters_zh":[{"name":"范围","range":"(2,77 - 32,92) mg/g"}],"search_zh":"电子烟补充液（e-liquid） 尼古丁含量 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-EN ISO 20714:2022-05","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"电子烟补充液（e-liquid）"},{"_id":"6a5dc9c4f1c10c8ce8260247","lab_id":"69ad52a3de79e566650fb94b","country":"PL","accr_number":"AB 1758","accr_body":"PCA","test_object":"Płyny do uzupełniania papierosów elektronicznych (e-liquid)","test_object_en":"Refill liquids for electronic cigarettes (e-liquid)","methodology":"Zawartość glikolu propylenowego","methodology_en":"Propylene glycol content","parameters":[{"name":"Zakres","range":"(178,4 - 862,1) mg/g"}],"parameters_en":[{"name":"Range","range":"(178,4 - 862,1) mg/g"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Zawartość glikolu propylenowego\nZakres (178,4 - 862,1) mg/g\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)","reference":"PN-EN ISO 20714:2022-05","norm_bases":["PN-EN ISO 20714:2022-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyny do uzupełniania papierosów elektronicznych (e-liquid) Zawartość glikolu propylenowego\nZakres (178,4 - 862,1) mg/g\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID) PN-EN ISO 20714:2022-05 Plyny do uzupelniania papierosow elektronicznych (e-liquid) Zawartosc glikolu propylenowego\nZakres (178,4 - 862,1) mg/g\nMetoda chromatografii gazowej z detekcja plomieniowo - jonizacyjna (GC-FID) PN-EN ISO 20714:2022-05","categories":["electronics"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Refill liquids for electronic cigarettes (e-liquid) Propylene glycol content Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 20714:2022-05","parameters_zh":[{"name":"范围","range":"(178,4 - 862,1) mg/g"}],"search_zh":"电子烟补充液（e-liquid） 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-EN ISO 20714:2022-05","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"电子烟补充液（e-liquid）"},{"_id":"6a5dc9c4f1c10c8ce8260248","lab_id":"69ad52a3de79e566650fb94b","country":"PL","accr_number":"AB 1758","accr_body":"PCA","test_object":"Płyny do uzupełniania papierosów elektronicznych (e-liquid)","test_object_en":"Refill liquids for electronic cigarettes (e-liquid)","methodology":"Zawartość gliceryny","methodology_en":"Glycerine content","parameters":[{"name":"Zakres","range":"(98,8 - 782,5) mg/g"}],"parameters_en":[{"name":"Range","range":"(98,8 - 782,5) mg/g"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Zawartość gliceryny\nZakres (98,8 - 782,5) mg/g\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)","reference":"PN-EN ISO 20714:2022-05","norm_bases":["PN-EN ISO 20714:2022-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyny do uzupełniania papierosów elektronicznych (e-liquid) Zawartość gliceryny\nZakres (98,8 - 782,5) mg/g\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID) PN-EN ISO 20714:2022-05 Plyny do uzupelniania papierosow elektronicznych (e-liquid) Zawartosc gliceryny\nZakres (98,8 - 782,5) mg/g\nMetoda chromatografii gazowej z detekcja plomieniowo - jonizacyjna (GC-FID) PN-EN ISO 20714:2022-05","categories":["electronics"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Refill liquids for electronic cigarettes (e-liquid) Glycerine content Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 20714:2022-05","parameters_zh":[{"name":"范围","range":"(98,8 - 782,5) mg/g"}],"search_zh":"电子烟补充液（e-liquid） 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-EN ISO 20714:2022-05","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"电子烟补充液（e-liquid）"},{"_id":"6a5dc9c4f1c10c8ce8260249","lab_id":"69ad52a3de79e566650fb94b","country":"PL","accr_number":"AB 1758","accr_body":"PCA","test_object":"Kosmetyki: Lakiery hybrydowe, Żele, Akrylożele","test_object_en":"Cosmetics: Hybrid nail polishes, Gels, Acrylic gels","methodology":"Zawartość tlenku","methodology_en":"Oxide content","parameters":[{"name":"trimetylobenzoilodifenylofosfiny (TPO)"},{"name":"Zakres","range":"(0,01 - 25,00) %"}],"parameters_en":[{"name":"trimethylbenzoyldiphenylphosphine (TPO)"},{"name":"Range","range":"(0,01 - 25,00) %"}],"technique":"Metoda chromatografii cieczowej z detekcją matrycą fotodiodową (HPLC-PDA)","techniques":["Metoda chromatografii cieczowej z detekcją matrycą fotodiodową (HPLC-PDA)"],"technique_en":"Liquid chromatography with photodiode array detection (HPLC-PDA)","computed":[],"computed_en":[],"activity":"Zawartość tlenku\nZakres:\ntrimetylobenzoilodifenylofosfiny (TPO)\nZakres (0,01 - 25,00) %\nMetoda chromatografii cieczowej z detekcją matrycą fotodiodową (HPLC-PDA)","reference":"SL/2025/019 wyd. 1 z dnia 09.06.2025","norm_bases":["SL/2025/019 wyd. 1 z dnia 09.06.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kosmetyki: Lakiery hybrydowe, Żele, Akrylożele Zawartość tlenku\nZakres:\ntrimetylobenzoilodifenylofosfiny (TPO)\nZakres (0,01 - 25,00) %\nMetoda chromatografii cieczowej z detekcją matrycą fotodiodową (HPLC-PDA) SL/2025/019 wyd. 1 z dnia 09.06.2025 Kosmetyki: Lakiery hybrydowe, Zele, Akrylozele Zawartosc tlenku\nZakres:\ntrimetylobenzoilodifenylofosfiny (TPO)\nZakres (0,01 - 25,00) %\nMetoda chromatografii cieczowej z detekcja matryca fotodiodowa (HPLC-PDA) SL/2025/019 wyd. 1 z dnia 09.06.2025","categories":["automotive","pharma"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cosmetics: Hybrid nail polishes, Gels, Acrylic gels Oxide content Liquid chromatography with photodiode array detection (HPLC-PDA) trimethylbenzoyldiphenylphosphine (TPO) Range SL/2025/019 wyd. 1 z dnia 09.06.2025","parameters_zh":[{"name":"trimetylobenzoilodifenylofosfiny (TPO)"},{"name":"范围","range":"(0,01 - 25,00) %"}],"search_zh":"范围 SL/2025/019 wyd. 1 z dnia 09.06.2025"},{"_id":"6a5dc9c4f1c10c8ce826024a","lab_id":"69ad52a3de79e566650fb94b","country":"PL","accr_number":"AB 1758","accr_body":"PCA","test_object":"Pojemnik na e-liquid do papierosów elektronicznych","test_object_en":"E-liquid container for electronic cigarettes","methodology":"Pojemność","methodology_en":"Capacity","parameters":[{"name":"Zakres","range":"(0 – 12) ml"}],"parameters_en":[{"name":"Range","range":"(0 – 12) ml"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Pojemność\nZakres (0 – 12) ml\nMetoda wagowa","reference":"CEN/TS 17287:2019 Annex B","norm_bases":["CEN/TS 17287:2019 Annex B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pojemnik na e-liquid do papierosów elektronicznych Pojemność\nZakres (0 – 12) ml\nMetoda wagowa CEN/TS 17287:2019 Annex B Pojemnik na e-liquid do papierosow elektronicznych Pojemnosc\nZakres (0 – 12) ml\nMetoda wagowa CEN/TS 17287:2019 Annex B","categories":["electronics"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"E-liquid container for electronic cigarettes Capacity Gravimetric method Range CEN/TS 17287:2019 Annex B","parameters_zh":[{"name":"范围","range":"(0 – 12) ml"}],"search_zh":"容量 重量法 范围 CEN/TS 17287:2019 Annex B","technique_zh":"重量法","methodology_zh":"容量"},{"_id":"6a5dc9c4f1c10c8ce826024b","lab_id":"69ad52a3de79e566650fb94b","country":"PL","accr_number":"AB 1758","accr_body":"PCA","test_object":"Płyny do uzupełniania papierosów elektronicznych (e-liquid) E, Surowce i wyroby tytoniowe E","test_object_en":"Refill liquids for electronic cigarettes (e-liquid) E, Tobacco raw materials and products E","methodology":"Zawartość nikotyny","methodology_en":"Nicotine content","parameters":[{"name":"Zawartość soli nikotyny (z obliczeń)"}],"parameters_en":[{"name":"Nicotine salt content (calculated)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Zawartość nikotyny\nZawartość soli nikotyny (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyny do uzupełniania papierosów elektronicznych (e-liquid) E, Surowce i wyroby tytoniowe E Zawartość nikotyny\nZawartość soli nikotyny (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID) Procedury badawcze Plyny do uzupelniania papierosow elektronicznych (e-liquid) E, Surowce i wyroby tytoniowe E Zawartosc nikotyny\nZawartosc soli nikotyny (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo - jonizacyjna (GC-FID) Procedury badawcze","categories":["electronics"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Refill liquids for electronic cigarettes (e-liquid) E, Tobacco raw materials and products E Nicotine content Gas chromatography with flame ionization detection (GC-FID) Nicotine salt content (calculated) Procedury badawcze","methodology_zh":"尼古丁含量","search_zh":"尼古丁含量 气相色谱-火焰离子化检测法（GC-FID） Procedury badawcze","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）"},{"_id":"6a5dc9c4f1c10c8ce826024c","lab_id":"69ad52a3de79e566650fb94b","country":"PL","accr_number":"AB 1758","accr_body":"PCA","test_object":"Płyny do uzupełniania papierosów elektronicznych (e-liquid) E, Surowce konopne E, Produkty z dodatkiem konopi i/lub izolatów konopnych E","test_object_en":"Refill liquids for electronic cigarettes (e-liquid) E, Hemp raw materials E, Products with added hemp and/or hemp isolates E","methodology":"Zawartość kannabinoidów","methodology_en":"Cannabinoid content","parameters":[],"parameters_en":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją z matrycą diodową i tandemową spektrometrią mas (LC-PDA-MS/MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją z matrycą diodową i tandemową spektrometrią mas (LC-PDA-MS/MS)"],"technique_en":"High-performance liquid chromatography with diode array detection and tandem mass spectrometry (LC-PDA-MS/MS)","computed":[],"computed_en":[],"activity":"Zawartość kannabinoidów\nMetoda wysokosprawnej chromatografii cieczowej z detekcją z matrycą diodową i tandemową spektrometrią mas (LC-PDA-MS/MS)","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Płyny do uzupełniania papierosów elektronicznych (e-liquid) E, Surowce konopne E, Produkty z dodatkiem konopi i/lub izolatów konopnych E Zawartość kannabinoidów\nMetoda wysokosprawnej chromatografii cieczowej z detekcją z matrycą diodową i tandemową spektrometrią mas (LC-PDA-MS/MS) Procedury badawcze Plyny do uzupelniania papierosow elektronicznych (e-liquid) E, Surowce konopne E, Produkty z dodatkiem konopi i/lub izolatow konopnych E Zawartosc kannabinoidow\nMetoda wysokosprawnej chromatografii cieczowej z detekcja z matryca diodowa i tandemowa spektrometria mas (LC-PDA-MS/MS) Procedury badawcze","categories":["electronics"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Refill liquids for electronic cigarettes (e-liquid) E, Hemp raw materials E, Products with added hemp and/or hemp isolates E Cannabinoid content High-performance liquid chromatography with diode array detection and tandem mass spectrometry (LC-PDA-MS/MS) Procedury badawcze","methodology_zh":"大麻素含量","search_zh":"大麻素含量 Procedury badawcze"}],"has_pdf":true}