{"lab":{"_id":"69ad52a3de79e566650fb93b","accr_number":"AB 1749","country":"PL","accr_body":"PCA","address":"A. Wilczyńska-Piliszek, S. Piliszek, ul. gen. J. Sowińskiego 4/6, 80-143 Gdańsk, Instytut Analiz Środowiska, ul. gen. J. Sowińskiego 12/6, 80-143 Gdańsk","categories":["environment","construction"],"city":"Gdańsk","imported_at":"2026-03-08T10:42:43.265Z","methods_count":35,"name":"Firma Doradcza ISOTOP s.c.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1749.pdf"],"scope_summary":"","search_text":"firma doradcza isotop s.c. a. wilczyńska-piliszek, s. piliszek, ul. gen. j. sowińskiego 4/6, 80-143 gdańsk, instytut analiz środowiska, ul. gen. j. sowińskiego 12/6, 80-143 gdańsk environment other metrology pharma electronics materials automotive","status":"active","updated_at":"2026-03-08T14:50:52.222Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T15:09:06.148Z","email_confidence":"high","email_mx":true,"email_source":"https://isotop.pl/kontakt","fields_of_testing":[{"codes":"C/33","pl":"Badania chemiczne - powietrze","en":"Chemical tests – air"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czyn-niki szkodliwe i uciążliwe – hałas, hałas ultradźwiękowy, oświetlenie, drgania, mikroklimat, wyda-tek energetyczny, środki ochrony osobistej)","en":"Tests concerning environmental engineering (envi-ronmental and climatic) - working environment (harmful and nuisance factors – noise, ultrasonic noise, lighting, vibration, microclimate, energy expenditure, personal protection equipment)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas, oświetlenie)","en":"Tests concerning environmental engineering (environ-mental and climatic) - general environment (physical factors – noise, lighting)"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - po-wietrze)","en":"Tests of physical properties and sampling - working environment (harmful factors - air)"},{"codes":"P/33","pl":"Pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Sampling - working envi-ronment (harmful factors - air)"}],"issue":{"no":"9","date":"17.04.2026"},"parse_date":"2026-08-17T15:09:06.148Z","parse_source":"agent-claude-code","map_coord":[54.348291,18.654023],"map_geo":"nominatim-city","scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/0e1513d26f93a59c53d76417946b48c0/AB%201749.pdf","has_en":true,"category_counts":{"environment":35,"construction":2,"materials":1},"category_scores":{"environment":32.24,"construction":0.11,"materials":0.03},"has_zh":true},"methods":[{"_id":"6a832412884ede9a1b2c4f1b","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Szczytowy poziom dźwięku C","parameters":[{"name":"Równoważny poziom dźwięku A","range":"(27 - 137) dB"},{"name":"Maksymalny poziom dźwięku A","range":"(27 - 137) dB"},{"name":"Szczytowy poziom dźwięku C","range":"(50 - 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Szczytowy poziom dźwięku C\nZakres:\nRównoważny poziom dźwięku A (27 - 137) dB\nMaksymalny poziom dźwięku A (27 - 137) dB\nSzczytowy poziom dźwięku C (50 - 137) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11)","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11)"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Szczytowy poziom dźwięku C\nZakres:\nRównoważny poziom dźwięku A (27 - 137) dB\nMaksymalny poziom dźwięku A (27 - 137) dB\nSzczytowy poziom dźwięku C (50 - 137) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11) Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A Szczytowy poziom dzwieku C\nZakres:\nRownowazny poziom dzwieku A (27 - 137) dB\nMaksymalny poziom dzwieku A (27 - 137) dB\nSzczytowy poziom dzwieku C (50 - 137) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 (z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11)","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level C-weighted peak sound level","parameters_en":[{"name":"A-weighted equivalent sound pressure level","range":"(27 - 137) dB"},{"name":"Maximum A-weighted sound pressure level","range":"(27 - 137) dB"},{"name":"C-weighted peak sound pressure level","range":"(50 - 137) dB"}],"search_en":"Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level C-weighted peak sound level Direct measurement method A-weighted equivalent sound pressure level Maximum A-weighted sound pressure level C-weighted peak sound pressure level PN-N-01307:1994 | PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11)","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","parameters_zh":[{"name":"A 计权等效声级","range":"(27 - 137) dB"},{"name":"A 计权最大声级","range":"(27 - 137) dB"},{"name":"C 计权峰值声级","range":"(50 - 137) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 C 计权峰值声级 直接测量法 A 计权等效声级 A 计权最大声级 C 计权峰值声级 PN-N-01307:1994 | PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11)","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","methodology_zh":"A 计权等效声级 A 计权最大声级 C 计权峰值声级"},{"_id":"6a832412884ede9a1b2c4f1c","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do: - 8-godzinnego dobowego wymiaru czasu pracy (z obliczeń)","parameters":[{"name":"8-godzinnego dobowego wymiaru czasu pracy","range":null}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do: - 8-godzinnego dobowego wymiaru czasu pracy (z obliczeń)\n8-godzinnego dobowego wymiaru czasu pracy","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11)","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11)"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do: - 8-godzinnego dobowego wymiaru czasu pracy (z obliczeń)\n8-godzinnego dobowego wymiaru czasu pracy PN-N-01307:1994 | PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11) Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do: - 8-godzinnego dobowego wymiaru czasu pracy (z obliczen)\n8-godzinnego dobowego wymiaru czasu pracy PN-N-01307:1994 | PN-EN ISO 9612:2025-11 (z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11)","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level normalised to: - an 8-hour working day (calculated)","parameters_en":[{"name":"an 8-hour daily working time","range":null}],"search_en":"Workplace environment - noise Noise exposure level normalised to: - an 8-hour working day (calculated) an 8-hour daily working time PN-N-01307:1994 | PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11)","test_object_en":"Workplace environment - noise","search_zh":"工作场所环境 — 噪声 8 小时日工作时间 PN-N-01307:1994 | PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11)","test_object_zh":"工作场所环境 — 噪声","parameters_zh":[{"name":"8 小时日工作时间","range":null}]},{"_id":"6a832412884ede9a1b2c4f1d","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do: - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","parameters":[{"name":"przeciętnego tygodniowego wymiaru czasu pracy","range":null}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do: - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)\nprzeciętnego tygodniowego wymiaru czasu pracy","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11)","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11)"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do: - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)\nprzeciętnego tygodniowego wymiaru czasu pracy PN-N-01307:1994 | PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11) Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do: - przecietnego tygodniowego wymiaru czasu pracy (z obliczen)\nprzecietnego tygodniowego wymiaru czasu pracy PN-N-01307:1994 | PN-EN ISO 9612:2025-11 (z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11)","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"average weekly working time","range":null}],"search_en":"Workplace environment - noise average weekly working time PN-N-01307:1994 | PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11)","test_object_en":"Workplace environment - noise","search_zh":"工作场所环境 — 噪声 PN-N-01307:1994 | PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11)","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a832412884ede9a1b2c4f1e","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy - hałas (dobór ochronników słuchu)","methodology":"Równoważny poziom ciśnienia akustycznego w pasmach częstotliwo-ściowych oktawowych Równoważny poziom dźwięku A Równoważny poziom dźwięku C","parameters":[{"name":"Równoważny poziom ciśnienia akustycznego w pasmach częstotliwo-ściowych oktawowych","range":"(63 - 8000) Hz"},{"name":"Równoważny poziom dźwięku A","range":"(30 - 137) dB"},{"name":"Równoważny poziom dźwięku C","range":"(30 - 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom ciśnienia akustycznego w pasmach częstotliwo-ściowych oktawowych Równoważny poziom dźwięku A Równoważny poziom dźwięku C\nZakres:\nRównoważny poziom ciśnienia akustycznego w pasmach częstotliwo-ściowych oktawowych (63 - 8000) Hz\nRównoważny poziom dźwięku A (30 - 137) dB\nRównoważny poziom dźwięku C (30 - 137) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 z wyłączeniem metody SNR | PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11)","norm_bases":["PN-EN 458:2016-06","PN-EN ISO 4869-2:2018-12 z wyłączeniem metody SNR","PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11)"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas (dobór ochronników słuchu) Równoważny poziom ciśnienia akustycznego w pasmach częstotliwo-ściowych oktawowych Równoważny poziom dźwięku A Równoważny poziom dźwięku C\nZakres:\nRównoważny poziom ciśnienia akustycznego w pasmach częstotliwo-ściowych oktawowych (63 - 8000) Hz\nRównoważny poziom dźwięku A (30 - 137) dB\nRównoważny poziom dźwięku C (30 - 137) dB\nMetoda pomiarowa bezpośrednia PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 z wyłączeniem metody SNR | PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11) Srodowisko pracy - halas (dobor ochronnikow sluchu) Rownowazny poziom cisnienia akustycznego w pasmach czestotliwo-sciowych oktawowych Rownowazny poziom dzwieku A Rownowazny poziom dzwieku C\nZakres:\nRownowazny poziom cisnienia akustycznego w pasmach czestotliwo-sciowych oktawowych (63 - 8000) Hz\nRownowazny poziom dzwieku A (30 - 137) dB\nRownowazny poziom dzwieku C (30 - 137) dB\nMetoda pomiarowa bezposrednia PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 z wylaczeniem metody SNR | PN-EN ISO 9612:2025-11 (z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11)","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Równoważny poziom ciśnienia akustycznego w pasmach częstotliwo-ściowych oktawowych","range":"(63 - 8000) Hz"},{"name":"A-weighted equivalent sound pressure level","range":"(30 - 137) dB"},{"name":"Equivalent C-weighted sound level","range":"(30 - 137) dB"}],"search_en":"Workplace environment - noise (selection of hearing protectors) Direct measurement method A-weighted equivalent sound pressure level Equivalent C-weighted sound level PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 z wyłączeniem metody SNR | PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11)","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise (selection of hearing protectors)","parameters_zh":[{"name":"Równoważny poziom ciśnienia akustycznego w pasmach częstotliwo-ściowych oktawowych","range":"(63 - 8000) Hz"},{"name":"A 计权等效声级","range":"(30 - 137) dB"},{"name":"Równoważny poziom dźwięku C","range":"(30 - 137) dB"}],"search_zh":"直接测量法 A 计权等效声级 PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 z wyłączeniem metody SNR | PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11)","technique_zh":"直接测量法"},{"_id":"6a832412884ede9a1b2c4f1f","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy - hałas (dobór ochronników słuchu)","methodology":"Równoważny poziom dźwięku A pod ochronnikami słuchu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A pod ochronnikami słuchu (z obliczeń)","reference":"PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 z wyłączeniem metody SNR | PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11)","norm_bases":["PN-EN 458:2016-06","PN-EN ISO 4869-2:2018-12 z wyłączeniem metody SNR","PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11)"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas (dobór ochronników słuchu) Równoważny poziom dźwięku A pod ochronnikami słuchu (z obliczeń) PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 z wyłączeniem metody SNR | PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11) Srodowisko pracy - halas (dobor ochronnikow sluchu) Rownowazny poziom dzwieku A pod ochronnikami sluchu (z obliczen) PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 z wylaczeniem metody SNR | PN-EN ISO 9612:2025-11 (z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11)","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level under hearing protectors (calculated)","search_en":"Workplace environment - noise (selection of hearing protectors) A-weighted equivalent sound level under hearing protectors (calculated) PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 z wyłączeniem metody SNR | PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11)","test_object_en":"Workplace environment - noise (selection of hearing protectors)","methodology_zh":"佩戴听力护具下的 A 计权等效声级（由计算得出）","search_zh":"佩戴听力护具下的 A 计权等效声级（由计算得出） PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 z wyłączeniem metody SNR | PN-EN ISO 9612:2025-11 (z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11)"},{"_id":"6a832412884ede9a1b2c4f20","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy – hałas ultradźwiękowy","methodology":"Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz","parameters":[{"name":"Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz","range":"(55 – 159) dB"},{"name":"Maksymalny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz","range":"(55 – 159) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz\nZakres:\nRównoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz (55 – 159) dB\nMaksymalny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz (55 – 159) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-Z-01339:2020-12","norm_bases":["PN-Z-01339:2020-12"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas ultradźwiękowy Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz\nZakres:\nRównoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz (55 – 159) dB\nMaksymalny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz (55 – 159) dB\nMetoda pomiarowa bezpośrednia PN-Z-01339:2020-12 Srodowisko pracy – halas ultradzwiekowy Rownowazny poziom cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz Maksymalny poziom cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz\nZakres:\nRownowazny poziom cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz (55 – 159) dB\nMaksymalny poziom cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz (55 – 159) dB\nMetoda pomiarowa bezposrednia PN-Z-01339:2020-12","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz","parameters_en":[{"name":"Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz","range":"(55 – 159) dB"},{"name":"Maximum sound pressure level in third-octave bands with centre frequencies from 10 kHz to 40 kHz","range":"(55 – 159) dB"}],"search_en":"Workplace environment – ultrasonic noise Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Direct measurement method Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure level in third-octave bands with centre frequencies from 10 kHz to 40 kHz PN-Z-01339:2020-12","technique_en":"Direct measurement method","test_object_en":"Workplace environment – ultrasonic noise","search_zh":"工作场所环境 — 超声噪声 中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级 中心频率自 10 kHz 至 40 kHz 的1/3倍频程最大声压级 直接测量法 PN-Z-01339:2020-12","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 超声噪声","methodology_zh":"中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级 中心频率自 10 kHz 至 40 kHz 的1/3倍频程最大声压级"},{"_id":"6a832412884ede9a1b2c4f21","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy – hałas ultradźwiękowy","methodology":"Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do: - 8 - godz. dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","parameters":[{"name":"8 - godz. dobowego wymiaru czasu pracy","range":null},{"name":"przeciętnego tygodniowego wymiaru czasu pracy","range":null}],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do: - 8 - godz. dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy","reference":"PN-Z-01339:2020-12","norm_bases":["PN-Z-01339:2020-12"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas ultradźwiękowy Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do: - 8 - godz. dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy PN-Z-01339:2020-12 Srodowisko pracy – halas ultradzwiekowy Rownowazny poziom cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz odniesione do: - 8 - godz. dobowego wymiaru czasu pracy - przecietnego tygodniowego wymiaru czasu pracy (z obliczen)\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy PN-Z-01339:2020-12","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz referred to: - the 8-hour daily working time - the average weekly working time (calculated)","parameters_en":[{"name":"an 8-hour daily working time","range":null},{"name":"average weekly working time","range":null}],"search_en":"Workplace environment – ultrasonic noise Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz referred to: - the 8-hour daily working time - the average weekly working time (calculated) an 8-hour daily working time average weekly working time PN-Z-01339:2020-12","test_object_en":"Workplace environment – ultrasonic noise","search_zh":"工作场所环境 — 超声噪声 每日 8 小时工作时间 PN-Z-01339:2020-12","test_object_zh":"工作场所环境 — 超声噪声","parameters_zh":[{"name":"每日 8 小时工作时间","range":null},{"name":"przeciętnego tygodniowego wymiaru czasu pracy","range":null}]},{"_id":"6a832412884ede9a1b2c4f22","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysło-wych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Równoważny poziom dźwięku A","range":"(28 – 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres: (28 – 137) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysło-wych Równoważny poziom dźwięku A\nZakres: (28 – 137) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslo-wych Rownowazny poziom dzwieku A\nZakres: (28 – 137) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"A-weighted equivalent sound pressure level","range":"(28 – 137) dB"}],"search_en":"A-weighted equivalent sound pressure level Direct measurement method A-weighted equivalent sound pressure level Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","technique_en":"Direct measurement method","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"A 计权等效声级","range":"(28 – 137) dB"}],"search_zh":"A 计权等效声级 直接测量法 A 计权等效声级 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法"},{"_id":"6a832412884ede9a1b2c4f23","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysło-wych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaź-nikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaź-nikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysło-wych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaź-nikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslo-wych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaz-nikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a832412884ede9a1b2c4f24","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","range":"(0,03 – 25) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres: (0,03 – 25) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres: (0,03 – 25) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres: (0,03 – 25) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Frequency-weighted r.m.s. vibration acceleration","range":"(0,03 – 25) m/s2"}],"search_en":"Workplace environment – whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Frequency-weighted r.m.s. vibration acceleration PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment – whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"频率计权振动加速度有效值","range":"(0,03 – 25) m/s2"}],"search_zh":"工作场所环境 — 全身振动 频率计权振动加速度有效值 直接测量法 频率计权振动加速度有效值 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a832412884ede9a1b2c4f25","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w po-staci równoważnego energetycznie dla 8 godzin działania skutecznego, sko-rygowanego częstotliwościowo przy-spieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współ-czynników (1,4awx, 1,4awy, awz) Ekspozycja trwająca 30 minut i krócej wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspie-szenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współ-czynników (1,4awx, 1,4awy, awz) (z obliczeń)","parameters":[{"name":"Ekspozycja dzienna, wyrażona w po-staci równoważnego energetycznie dla 8 godzin działania skutecznego, sko-rygowanego częstotliwościowo przy-spieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współ-czynników (1,4awx, 1,4awy, awz)","range":null},{"name":"Ekspozycja trwająca 30 minut i krócej wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspie-szenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współ-czynników (1,4awx, 1,4awy, awz)","range":null}],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w po-staci równoważnego energetycznie dla 8 godzin działania skutecznego, sko-rygowanego częstotliwościowo przy-spieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współ-czynników (1,4awx, 1,4awy, awz) Ekspozycja trwająca 30 minut i krócej wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspie-szenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współ-czynników (1,4awx, 1,4awy, awz) (z obliczeń)\nZakres:\nEkspozycja dzienna, wyrażona w po-staci równoważnego energetycznie dla 8 godzin działania skutecznego, sko-rygowanego częstotliwościowo przy-spieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współ-czynników (1,4awx, 1,4awy, awz)\nEkspozycja trwająca 30 minut i krócej wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspie-szenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współ-czynników (1,4awx, 1,4awy, awz)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w po-staci równoważnego energetycznie dla 8 godzin działania skutecznego, sko-rygowanego częstotliwościowo przy-spieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współ-czynników (1,4awx, 1,4awy, awz) Ekspozycja trwająca 30 minut i krócej wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspie-szenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współ-czynników (1,4awx, 1,4awy, awz) (z obliczeń)\nZakres:\nEkspozycja dzienna, wyrażona w po-staci równoważnego energetycznie dla 8 godzin działania skutecznego, sko-rygowanego częstotliwościowo przy-spieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współ-czynników (1,4awx, 1,4awy, awz)\nEkspozycja trwająca 30 minut i krócej wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspie-szenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współ-czynników (1,4awx, 1,4awy, awz) PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w po-staci rownowaznego energetycznie dla 8 godzin dzialania skutecznego, sko-rygowanego czestotliwosciowo przy-spieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspol-czynnikow (1,4awx, 1,4awy, awz) Ekspozycja trwajaca 30 minut i krocej wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspie-szenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspol-czynnikow (1,4awx, 1,4awy, awz) (z obliczen)\nZakres:\nEkspozycja dzienna, wyrazona w po-staci rownowaznego energetycznie dla 8 godzin dzialania skutecznego, sko-rygowanego czestotliwosciowo przy-spieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspol-czynnikow (1,4awx, 1,4awy, awz)\nEkspozycja trwajaca 30 minut i krocej wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspie-szenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspol-czynnikow (1,4awx, 1,4awy, awz) PN-EN 14253+A1:2011","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Workplace environment – whole-body vibration PN-EN 14253+A1:2011","test_object_en":"Workplace environment – whole-body vibration","search_zh":"工作场所环境 — 全身振动 PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a832412884ede9a1b2c4f26","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","range":"(0,32 - 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres: (0,32 - 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres: (0,32 - 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres: (0,32 - 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Frequency-weighted r.m.s. vibration acceleration","range":"(0,32 - 100) m/s2"}],"search_en":"Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Frequency-weighted r.m.s. vibration acceleration PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"频率计权振动加速度有效值","range":"(0,32 - 100) m/s2"}],"search_zh":"工作场所环境 — 手传振动 频率计权振动加速度有效值 直接测量法 频率计权振动加速度有效值 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a832412884ede9a1b2c4f27","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w po-staci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych często-tliwościowo przyspieszeń drgań wy-znaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) Ekspozycja trwająca 30 minut i krócej wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwo-ściowo przyspieszeń drgań, wyzna-czonych dla trzech składowych kierun-kowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[{"name":"Ekspozycja dzienna, wyrażona w po-staci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych często-tliwościowo przyspieszeń drgań wy-znaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)","range":null},{"name":"Ekspozycja trwająca 30 minut i krócej wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwo-ściowo przyspieszeń drgań, wyzna-czonych dla trzech składowych kierun-kowych (ahwx, ahwy, ahwz)","range":null}],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w po-staci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych często-tliwościowo przyspieszeń drgań wy-znaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) Ekspozycja trwająca 30 minut i krócej wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwo-ściowo przyspieszeń drgań, wyzna-czonych dla trzech składowych kierun-kowych (ahwx, ahwy, ahwz) (z obliczeń)\nZakres:\nEkspozycja dzienna, wyrażona w po-staci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych często-tliwościowo przyspieszeń drgań wy-znaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)\nEkspozycja trwająca 30 minut i krócej wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwo-ściowo przyspieszeń drgań, wyzna-czonych dla trzech składowych kierun-kowych (ahwx, ahwy, ahwz)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w po-staci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych często-tliwościowo przyspieszeń drgań wy-znaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) Ekspozycja trwająca 30 minut i krócej wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwo-ściowo przyspieszeń drgań, wyzna-czonych dla trzech składowych kierun-kowych (ahwx, ahwy, ahwz) (z obliczeń)\nZakres:\nEkspozycja dzienna, wyrażona w po-staci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych często-tliwościowo przyspieszeń drgań wy-znaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)\nEkspozycja trwająca 30 minut i krócej wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwo-ściowo przyspieszeń drgań, wyzna-czonych dla trzech składowych kierun-kowych (ahwx, ahwy, ahwz) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w po-staci rownowaznej energetycznie dla 8 godzin dzialania sumy wektorowej skutecznych, skorygowanych czesto-tliwosciowo przyspieszen drgan wy-znaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) Ekspozycja trwajaca 30 minut i krocej wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwo-sciowo przyspieszen drgan, wyzna-czonych dla trzech skladowych kierun-kowych (ahwx, ahwy, ahwz) (z obliczen)\nZakres:\nEkspozycja dzienna, wyrazona w po-staci rownowaznej energetycznie dla 8 godzin dzialania sumy wektorowej skutecznych, skorygowanych czesto-tliwosciowo przyspieszen drgan wy-znaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz)\nEkspozycja trwajaca 30 minut i krocej wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwo-sciowo przyspieszen drgan, wyzna-czonych dla trzech skladowych kierun-kowych (ahwx, ahwy, ahwz) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Workplace environment – hand-arm vibration PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_en":"Workplace environment – hand-arm vibration","search_zh":"工作场所环境 — 手传振动 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a832412884ede9a1b2c4f28","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Natężenie oświetlenia","range":"(0,5 – 9800) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres: (0,5 – 9800) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres: (0,5 – 9800) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy − oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres: (0,5 – 9800) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Illuminance","range":"(0,5 – 9800) lx"}],"search_en":"Workplace environment − indoor electric lighting Illuminance Direct measurement method Illuminance PN-83/E-04040.03","technique_en":"Direct measurement method","test_object_en":"Workplace environment − indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"照度","range":"(0,5 – 9800) lx"}],"search_zh":"工作场所环境 − 室内电气照明 照度 直接测量法 照度 PN-83/E-04040.03","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 室内电气照明"},{"_id":"6a832412884ede9a1b2c4f29","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy − oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment − indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03","test_object_en":"Workplace environment − indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 − 室内电气照明 照度均匀度（计算值） PN-83/E-04040.03","test_object_zh":"工作场所环境 − 室内电气照明"},{"_id":"6a832412884ede9a1b2c4f2a","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy oraz środowisko ogólne − oświetlenie elektryczne na zewnątrz","methodology":"Natężenie oświetlenia","parameters":[{"name":"Natężenie oświetlenia","range":"(0,5 – 9800) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres: (0,5 – 9800) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy oraz środowisko ogólne − oświetlenie elektryczne na zewnątrz Natężenie oświetlenia\nZakres: (0,5 – 9800) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy oraz srodowisko ogolne − oswietlenie elektryczne na zewnatrz Natezenie oswietlenia\nZakres: (0,5 – 9800) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Illuminance","range":"(0,5 – 9800) lx"}],"search_en":"Workplace environment and general environment − outdoor electric lighting Illuminance Direct measurement method Illuminance PN-83/E-04040.03","technique_en":"Direct measurement method","test_object_en":"Workplace environment and general environment − outdoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"照度","range":"(0,5 – 9800) lx"}],"search_zh":"照度 直接测量法 照度 PN-83/E-04040.03","technique_zh":"直接测量法"},{"_id":"6a832412884ede9a1b2c4f2b","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy oraz środowisko ogólne − oświetlenie elektryczne na zewnątrz","methodology":"Równomierność oświetlenia Zróżnicowanie oświetlenia (z obliczeń)","parameters":[{"name":"Równomierność oświetlenia","range":null},{"name":"Zróżnicowanie oświetlenia","range":null}],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia Zróżnicowanie oświetlenia (z obliczeń)\nZakres:\nRównomierność oświetlenia\nZróżnicowanie oświetlenia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy oraz środowisko ogólne − oświetlenie elektryczne na zewnątrz Równomierność oświetlenia Zróżnicowanie oświetlenia (z obliczeń)\nZakres:\nRównomierność oświetlenia\nZróżnicowanie oświetlenia PN-83/E-04040.03 Srodowisko pracy oraz srodowisko ogolne − oswietlenie elektryczne na zewnatrz Rownomiernosc oswietlenia Zroznicowanie oswietlenia (z obliczen)\nZakres:\nRownomiernosc oswietlenia\nZroznicowanie oswietlenia PN-83/E-04040.03","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Illuminance uniformity","range":null},{"name":"Zróżnicowanie oświetlenia","range":null}],"search_en":"Workplace environment and general environment − outdoor electric lighting Illuminance uniformity PN-83/E-04040.03","test_object_en":"Workplace environment and general environment − outdoor electric lighting","parameters_zh":[{"name":"照度均匀度","range":null},{"name":"Zróżnicowanie oświetlenia","range":null}],"search_zh":"照度均匀度 PN-83/E-04040.03"},{"_id":"6a832412884ede9a1b2c4f2c","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie awaryjne","methodology":"Natężenie oświetlenia","parameters":[{"name":"Natężenie oświetlenia","range":"(0,5 – 500) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres: (0,5 – 500) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7","norm_bases":["PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie awaryjne Natężenie oświetlenia\nZakres: (0,5 – 500) lx\nMetoda pomiarowa bezpośrednia PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7 Srodowisko pracy − oswietlenie awaryjne Natezenie oswietlenia\nZakres: (0,5 – 500) lx\nMetoda pomiarowa bezposrednia PN-EN 1838:2025-05 z wylaczeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Illuminance","range":"(0,5 – 500) lx"}],"search_en":"Workplace environment − emergency lighting Illuminance Direct measurement method Illuminance PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7","technique_en":"Direct measurement method","test_object_en":"Workplace environment − emergency lighting","methodology_zh":"照度","parameters_zh":[{"name":"照度","range":"(0,5 – 500) lx"}],"search_zh":"工作环境 － 应急照明 照度 直接测量法 照度 PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7","technique_zh":"直接测量法","test_object_zh":"工作环境 － 应急照明"},{"_id":"6a832412884ede9a1b2c4f2d","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie awaryjne","methodology":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","reference":"PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7","norm_bases":["PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie awaryjne Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń) PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7 Srodowisko pracy − oswietlenie awaryjne Stosunek minimalnego do maksymalnego natezenia oswietlenia (z obliczen) PN-EN 1838:2025-05 z wylaczeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ratio of minimum to maximum illuminance (calculated)","search_en":"Workplace environment − emergency lighting Ratio of minimum to maximum illuminance (calculated) PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7","test_object_en":"Workplace environment − emergency lighting","methodology_zh":"最小与最大照度之比（计算值）","search_zh":"工作环境 － 应急照明 最小与最大照度之比（计算值） PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7","test_object_zh":"工作环境 － 应急照明"},{"_id":"6a832412884ede9a1b2c4f2e","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie awaryjne","methodology":"Czas załączania","parameters":[{"name":"Czas załączania","range":"(1 – 80) s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Czas załączania\nZakres: (1 – 80) s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7","norm_bases":["PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie awaryjne Czas załączania\nZakres: (1 – 80) s\nMetoda pomiarowa bezpośrednia PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7 Srodowisko pracy − oswietlenie awaryjne Czas zalaczania\nZakres: (1 – 80) s\nMetoda pomiarowa bezposrednia PN-EN 1838:2025-05 z wylaczeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Closing time","parameters_en":[{"name":"Closing time","range":"(1 – 80) s"}],"search_en":"Workplace environment − emergency lighting Closing time Direct measurement method Closing time PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7","technique_en":"Direct measurement method","test_object_en":"Workplace environment − emergency lighting","search_zh":"工作环境 － 应急照明 接通时间 直接测量法 接通时间 PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7","technique_zh":"直接测量法","test_object_zh":"工作环境 － 应急照明","methodology_zh":"接通时间","parameters_zh":[{"name":"接通时间","range":"(1 – 80) s"}]},{"_id":"6a832412884ede9a1b2c4f2f","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie awaryjne","methodology":"Czas działania","parameters":[{"name":"Czas działania","range":"(1 – 60) min"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Czas działania\nZakres: (1 – 60) min\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7","norm_bases":["PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie awaryjne Czas działania\nZakres: (1 – 60) min\nMetoda pomiarowa bezpośrednia PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7 Srodowisko pracy − oswietlenie awaryjne Czas dzialania\nZakres: (1 – 60) min\nMetoda pomiarowa bezposrednia PN-EN 1838:2025-05 z wylaczeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Operation time","parameters_en":[{"name":"Operation time","range":"(1 – 60) min"}],"search_en":"Workplace environment − emergency lighting Operation time Direct measurement method Operation time PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7","technique_en":"Direct measurement method","test_object_en":"Workplace environment − emergency lighting","search_zh":"工作环境 － 应急照明 直接测量法 PN-EN 1838:2025-05 z wyłączeniem pkt. 5.1.3-5.1.4, 5.1.7-5.1.8, 5.2.3-5.2.4, 5.2.7, 5.3.4 - 5.3.5, 5.3.7- 5.3.8, 6, 7","technique_zh":"直接测量法","test_object_zh":"工作环境 － 应急照明"},{"_id":"6a832412884ede9a1b2c4f30","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat umiarkowany","methodology":"Temperatura powietrza Temperatura poczernionej kuli Wilgotność powietrza Prędkość powietrza","parameters":[{"name":"Temperatura powietrza","range":"(5,0 - 40,0) °C"},{"name":"Temperatura poczernionej kuli","range":"(5,0 - 40,0) °C"},{"name":"Wilgotność powietrza","range":"(25,0 - 75,0) %"},{"name":"Prędkość powietrza","range":"(0,15 - 5,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza Temperatura poczernionej kuli Wilgotność powietrza Prędkość powietrza\nZakres:\nTemperatura powietrza (5,0 - 40,0) °C\nTemperatura poczernionej kuli (5,0 - 40,0) °C\nWilgotność powietrza (25,0 - 75,0) %\nPrędkość powietrza (0,15 - 5,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat umiarkowany Temperatura powietrza Temperatura poczernionej kuli Wilgotność powietrza Prędkość powietrza\nZakres:\nTemperatura powietrza (5,0 - 40,0) °C\nTemperatura poczernionej kuli (5,0 - 40,0) °C\nWilgotność powietrza (25,0 - 75,0) %\nPrędkość powietrza (0,15 - 5,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy − mikroklimat umiarkowany Temperatura powietrza Temperatura poczernionej kuli Wilgotnosc powietrza Predkosc powietrza\nZakres:\nTemperatura powietrza (5,0 - 40,0) °C\nTemperatura poczernionej kuli (5,0 - 40,0) °C\nWilgotnosc powietrza (25,0 - 75,0) %\nPredkosc powietrza (0,15 - 5,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Air temperature","range":"(5,0 - 40,0) °C"},{"name":"Black globe temperature","range":"(5,0 - 40,0) °C"},{"name":"Air humidity","range":"(25,0 - 75,0) %"},{"name":"Air velocity","range":"(0,15 - 5,0) m/s"}],"search_en":"Workplace environment − moderate microclimate Direct measurement method Air temperature Black globe temperature Air humidity Air velocity PN-EN ISO 7730:2006+Ap2:2016-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment − moderate microclimate","parameters_zh":[{"name":"空气温度","range":"(5,0 - 40,0) °C"},{"name":"黑球温度","range":"(5,0 - 40,0) °C"},{"name":"空气湿度","range":"(25,0 - 75,0) %"},{"name":"空气流速","range":"(0,15 - 5,0) m/s"}],"search_zh":"工作场所环境 − 中等微气候 直接测量法 空气温度 黑球温度 空气湿度 空气流速 PN-EN ISO 7730:2006+Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 中等微气候"},{"_id":"6a832412884ede9a1b2c4f31","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat umiarkowany","methodology":"Wskaźnik PMV Wskaźnik PPD (z obliczeń)","parameters":[{"name":"Wskaźnik PMV","range":null},{"name":"Wskaźnik PPD","range":null}],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV Wskaźnik PPD (z obliczeń)\nZakres:\nWskaźnik PMV\nWskaźnik PPD","reference":"PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat umiarkowany Wskaźnik PMV Wskaźnik PPD (z obliczeń)\nZakres:\nWskaźnik PMV\nWskaźnik PPD PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy − mikroklimat umiarkowany Wskaznik PMV Wskaznik PPD (z obliczen)\nZakres:\nWskaznik PMV\nWskaznik PPD PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PMV index PPD index (calculated)","parameters_en":[{"name":"PMV index","range":null},{"name":"Wskaźnik PPD","range":null}],"search_en":"Workplace environment − moderate microclimate PMV index PPD index (calculated) PMV index PN-EN ISO 7730:2006+Ap2:2016-04","test_object_en":"Workplace environment − moderate microclimate","search_zh":"工作场所环境 − 中等微气候 PMV 指数 PPD 指数（计算值） PMV 指数 PN-EN ISO 7730:2006+Ap2:2016-04","test_object_zh":"工作场所环境 − 中等微气候","methodology_zh":"PMV 指数 PPD 指数（计算值）","parameters_zh":[{"name":"PMV 指数","range":null},{"name":"Wskaźnik PPD","range":null}]},{"_id":"6a832412884ede9a1b2c4f32","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","methodology":"Temperatura powietrza Temperatura wilgotna naturalna Temperatura poczernionej kuli","parameters":[{"name":"Temperatura powietrza","range":"(15,0 - 60,0) °C"},{"name":"Temperatura wilgotna naturalna","range":"(15,0 - 60,0) °C"},{"name":"Temperatura poczernionej kuli","range":"(15,0 - 60,0) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza Temperatura wilgotna naturalna Temperatura poczernionej kuli\nZakres:\nTemperatura powietrza (15,0 - 60,0) °C\nTemperatura wilgotna naturalna (15,0 - 60,0) °C\nTemperatura poczernionej kuli (15,0 - 60,0) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01+Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01+Ap2:2020-04"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat gorący Temperatura powietrza Temperatura wilgotna naturalna Temperatura poczernionej kuli\nZakres:\nTemperatura powietrza (15,0 - 60,0) °C\nTemperatura wilgotna naturalna (15,0 - 60,0) °C\nTemperatura poczernionej kuli (15,0 - 60,0) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01+Ap2:2020-04 Srodowisko pracy − mikroklimat goracy Temperatura powietrza Temperatura wilgotna naturalna Temperatura poczernionej kuli\nZakres:\nTemperatura powietrza (15,0 - 60,0) °C\nTemperatura wilgotna naturalna (15,0 - 60,0) °C\nTemperatura poczernionej kuli (15,0 - 60,0) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01+Ap2:2020-04","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Air temperature","range":"(15,0 - 60,0) °C"},{"name":"Natural wet bulb temperature","range":"(15,0 - 60,0) °C"},{"name":"Black globe temperature","range":"(15,0 - 60,0) °C"}],"search_en":"Workplace environment − hot microclimate Direct measurement method Air temperature Natural wet bulb temperature Black globe temperature PN-EN ISO 7243:2018-01+Ap2:2020-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment − hot microclimate","parameters_zh":[{"name":"空气温度","range":"(15,0 - 60,0) °C"},{"name":"自然湿球温度","range":"(15,0 - 60,0) °C"},{"name":"黑球温度","range":"(15,0 - 60,0) °C"}],"search_zh":"工作场所环境 − 高温微气候 直接测量法 空气温度 自然湿球温度 黑球温度 PN-EN ISO 7243:2018-01+Ap2:2020-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 高温微气候"},{"_id":"6a832412884ede9a1b2c4f33","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","methodology":"Wskaźnik WBGT Wskaźnik WBGTeff (z obliczeń)","parameters":[{"name":"Wskaźnik WBGT","range":null},{"name":"Wskaźnik WBGTeff","range":null}],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT Wskaźnik WBGTeff (z obliczeń)\nZakres:\nWskaźnik WBGT\nWskaźnik WBGTeff","reference":"PN-EN ISO 7243:2018-01+Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01+Ap2:2020-04"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat gorący Wskaźnik WBGT Wskaźnik WBGTeff (z obliczeń)\nZakres:\nWskaźnik WBGT\nWskaźnik WBGTeff PN-EN ISO 7243:2018-01+Ap2:2020-04 Srodowisko pracy − mikroklimat goracy Wskaznik WBGT Wskaznik WBGTeff (z obliczen)\nZakres:\nWskaznik WBGT\nWskaznik WBGTeff PN-EN ISO 7243:2018-01+Ap2:2020-04","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"WBGT index WBGTeff index (calculated)","parameters_en":[{"name":"WBGT index","range":null},{"name":"Wskaźnik WBGTeff","range":null}],"search_en":"Workplace environment − hot microclimate WBGT index WBGTeff index (calculated) WBGT index PN-EN ISO 7243:2018-01+Ap2:2020-04","test_object_en":"Workplace environment − hot microclimate","search_zh":"工作场所环境 − 高温微气候 WBGT 指数 WBGTeff 指数（由计算得出） PN-EN ISO 7243:2018-01+Ap2:2020-04","test_object_zh":"工作场所环境 − 高温微气候","methodology_zh":"WBGT 指数 WBGTeff 指数（由计算得出）"},{"_id":"6a832412884ede9a1b2c4f34","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat zimny","methodology":"Temperatura powietrza Temperatura poczernionej kuli Wilgotność powietrza Prędkość powietrza","parameters":[{"name":"Temperatura powietrza","range":"(- 30,0 - 10,0) °C"},{"name":"Temperatura poczernionej kuli","range":"(- 30,0 - 15,0) °C"},{"name":"Wilgotność powietrza","range":"(25,0 - 75,0) %"},{"name":"Prędkość powietrza","range":"(0,15 - 5,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza Temperatura poczernionej kuli Wilgotność powietrza Prędkość powietrza\nZakres:\nTemperatura powietrza (- 30,0 - 10,0) °C\nTemperatura poczernionej kuli (- 30,0 - 15,0) °C\nWilgotność powietrza (25,0 - 75,0) %\nPrędkość powietrza (0,15 - 5,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat zimny Temperatura powietrza Temperatura poczernionej kuli Wilgotność powietrza Prędkość powietrza\nZakres:\nTemperatura powietrza (- 30,0 - 10,0) °C\nTemperatura poczernionej kuli (- 30,0 - 15,0) °C\nWilgotność powietrza (25,0 - 75,0) %\nPrędkość powietrza (0,15 - 5,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy − mikroklimat zimny Temperatura powietrza Temperatura poczernionej kuli Wilgotnosc powietrza Predkosc powietrza\nZakres:\nTemperatura powietrza (- 30,0 - 10,0) °C\nTemperatura poczernionej kuli (- 30,0 - 15,0) °C\nWilgotnosc powietrza (25,0 - 75,0) %\nPredkosc powietrza (0,15 - 5,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Air temperature","range":"(- 30,0 - 10,0) °C"},{"name":"Black globe temperature","range":"(- 30,0 - 15,0) °C"},{"name":"Air humidity","range":"(25,0 - 75,0) %"},{"name":"Air velocity","range":"(0,15 - 5,0) m/s"}],"search_en":"Workplace environment − cold microclimate Direct measurement method Air temperature Black globe temperature Air humidity Air velocity PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment − cold microclimate","parameters_zh":[{"name":"空气温度","range":"(- 30,0 - 10,0) °C"},{"name":"黑球温度","range":"(- 30,0 - 15,0) °C"},{"name":"空气湿度","range":"(25,0 - 75,0) %"},{"name":"空气流速","range":"(0,15 - 5,0) m/s"}],"search_zh":"工作场所环境 − 低温微气候 直接测量法 空气温度 黑球温度 空气湿度 空气流速 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 低温微气候"},{"_id":"6a832412884ede9a1b2c4f35","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat zimny","methodology":"Wskaźnik IREQmin Wskaźnik IREQneutral Wskaźnik tWC (z obliczeń)","parameters":[{"name":"Wskaźnik IREQmin","range":null},{"name":"Wskaźnik IREQneutral","range":null},{"name":"Wskaźnik tWC","range":null}],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin Wskaźnik IREQneutral Wskaźnik tWC (z obliczeń)\nZakres:\nWskaźnik IREQmin\nWskaźnik IREQneutral\nWskaźnik tWC","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat zimny Wskaźnik IREQmin Wskaźnik IREQneutral Wskaźnik tWC (z obliczeń)\nZakres:\nWskaźnik IREQmin\nWskaźnik IREQneutral\nWskaźnik tWC PN-EN ISO 11079:2008 Srodowisko pracy − mikroklimat zimny Wskaznik IREQmin Wskaznik IREQneutral Wskaznik tWC (z obliczen)\nZakres:\nWskaznik IREQmin\nWskaznik IREQneutral\nWskaznik tWC PN-EN ISO 11079:2008","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"IREQmin index IREQneutral index tWC index (calculated)","parameters_en":[{"name":"IREQmin index","range":null},{"name":"Wskaźnik IREQneutral","range":null},{"name":"tWC index","range":null}],"search_en":"Workplace environment − cold microclimate IREQmin index IREQneutral index tWC index (calculated) IREQmin index tWC index PN-EN ISO 11079:2008","test_object_en":"Workplace environment − cold microclimate","search_zh":"工作场所环境 − 低温微气候 PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 − 低温微气候"},{"_id":"6a832412884ede9a1b2c4f36","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy − wydatek energetyczny","methodology":"Temperatura powietrza Przepływ powietrza","parameters":[{"name":"Temperatura powietrza","range":"(0 - 50)˚C"},{"name":"Przepływ powietrza","range":"(10 - 60) dm3/min"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza Przepływ powietrza\nZakres:\nTemperatura powietrza (0 - 50)˚C\nPrzepływ powietrza (10 - 60) dm3/min\nMetoda pomiarowa bezpośrednia","reference":"PB-02 wydanie 1 z dnia 30.06.2020 r.","norm_bases":["PB-02 wydanie 1 z dnia 30.06.2020 r."],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − wydatek energetyczny Temperatura powietrza Przepływ powietrza\nZakres:\nTemperatura powietrza (0 - 50)˚C\nPrzepływ powietrza (10 - 60) dm3/min\nMetoda pomiarowa bezpośrednia PB-02 wydanie 1 z dnia 30.06.2020 r. Srodowisko pracy − wydatek energetyczny Temperatura powietrza Przeplyw powietrza\nZakres:\nTemperatura powietrza (0 - 50)˚C\nPrzeplyw powietrza (10 - 60) dm3/min\nMetoda pomiarowa bezposrednia PB-02 wydanie 1 z dnia 30.06.2020 r.","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Air temperature","range":"(0 - 50)˚C"},{"name":"Air flow","range":"(10 - 60) dm3/min"}],"search_en":"Workplace environment − energy expenditure Direct measurement method Air temperature Air flow PB-02 wydanie 1 z dnia 30.06.2020 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − energy expenditure","parameters_zh":[{"name":"空气温度","range":"(0 - 50)˚C"},{"name":"空气流量","range":"(10 - 60) dm3/min"}],"search_zh":"工作环境 － 能量代谢消耗 直接测量法 空气温度 空气流量 PB-02 wydanie 1 z dnia 30.06.2020 r.","technique_zh":"直接测量法","test_object_zh":"工作环境 － 能量代谢消耗"},{"_id":"6a832412884ede9a1b2c4f37","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy − wydatek energetyczny","methodology":"Wydatek energetyczny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wydatek energetyczny (z obliczeń)","reference":"PB-02 wydanie 1 z dnia 30.06.2020 r.","norm_bases":["PB-02 wydanie 1 z dnia 30.06.2020 r."],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − wydatek energetyczny Wydatek energetyczny (z obliczeń) PB-02 wydanie 1 z dnia 30.06.2020 r. Srodowisko pracy − wydatek energetyczny Wydatek energetyczny (z obliczen) PB-02 wydanie 1 z dnia 30.06.2020 r.","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Energy expenditure (calculated)","search_en":"Workplace environment − energy expenditure Energy expenditure (calculated) PB-02 wydanie 1 z dnia 30.06.2020 r.","test_object_en":"Workplace environment − energy expenditure","methodology_zh":"能量消耗（计算值）","search_zh":"工作环境 － 能量代谢消耗 能量消耗（计算值） PB-02 wydanie 1 z dnia 30.06.2020 r.","test_object_zh":"工作环境 － 能量代谢消耗"},{"_id":"6a832412884ede9a1b2c4f38","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie tlenku węgla","parameters":[{"name":"Stężenie tlenku węgla","range":"(2,3 - 580) mg/m3"},{"name":"Stężenie tlenku węgla","range":"(2 - 500) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenku węgla\nZakres:\nStężenie tlenku węgla (2,3 - 580) mg/m3\nStężenie tlenku węgla (2 - 500) ppm\nMetoda elektrochemiczna","reference":"PB-01, wydanie 2 z dnia 12.03.2025 r.","norm_bases":["PB-01, wydanie 2 z dnia 12.03.2025 r."],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie tlenku węgla\nZakres:\nStężenie tlenku węgla (2,3 - 580) mg/m3\nStężenie tlenku węgla (2 - 500) ppm\nMetoda elektrochemiczna PB-01, wydanie 2 z dnia 12.03.2025 r. Srodowisko pracy - powietrze Stezenie tlenku wegla\nZakres:\nStezenie tlenku wegla (2,3 - 580) mg/m3\nStezenie tlenku wegla (2 - 500) ppm\nMetoda elektrochemiczna PB-01, wydanie 2 z dnia 12.03.2025 r.","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon monoxide concentration","parameters_en":[{"name":"Carbon monoxide concentration","range":"(2,3 - 580) mg/m3"},{"name":"Carbon monoxide concentration","range":"(2 - 500) ppm"}],"search_en":"Workplace environment - air Carbon monoxide concentration Electrochemical method Carbon monoxide concentration Carbon monoxide concentration PB-01, wydanie 2 z dnia 12.03.2025 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment - air","search_zh":"工作场所环境 — 空气 一氧化碳浓度 电化学法 一氧化碳浓度 一氧化碳浓度 PB-01, wydanie 2 z dnia 12.03.2025 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"一氧化碳浓度","parameters_zh":[{"name":"一氧化碳浓度","range":"(2,3 - 580) mg/m3"},{"name":"一氧化碳浓度","range":"(2 - 500) ppm"}]},{"_id":"6a832412884ede9a1b2c4f39","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PB-01, wydanie 2 z dnia 12.03.2025 r.","norm_bases":["PB-01, wydanie 2 z dnia 12.03.2025 r."],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PB-01, wydanie 2 z dnia 12.03.2025 r. Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PB-01, wydanie 2 z dnia 12.03.2025 r.","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air Exposure index (calculated) PB-01, wydanie 2 z dnia 12.03.2025 r.","test_object_en":"Workplace environment - air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PB-01, wydanie 2 z dnia 12.03.2025 r.","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a832412884ede9a1b2c4f3a","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek powietrza do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe","range":null},{"name":"frakcja wdychalna","range":null},{"name":"frakcja respirabilna","range":null},{"name":"substancje nieorganiczne, w tym","range":null},{"name":"frakcja respirabilna","range":null},{"name":"frakcja torakalna","range":null},{"name":"substancje organiczne, w tym","range":null},{"name":"frakcja wdychalna","range":null},{"name":"metale i ich związki, w tym","range":null},{"name":"frakcja wdychalna","range":null},{"name":"frakcja respirabilna","range":null},{"name":"respirabilne włókna azbestu","range":null}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek powietrza do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne, w tym\nfrakcja respirabilna\nfrakcja torakalna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nrespirabilne włókna azbestu\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek powietrza do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne, w tym\nfrakcja respirabilna\nfrakcja torakalna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nrespirabilne włókna azbestu\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Pobieranie probek powietrza do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne, w tym\nfrakcja respirabilna\nfrakcja torakalna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nmetale i ich zwiazki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nrespirabilne wlokna azbestu\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents","range":null},{"name":"inhalable fraction","range":null},{"name":"respirable fraction","range":null},{"name":"inorganic substances, including","range":null},{"name":"respirable fraction","range":null},{"name":"thoracic fraction","range":null},{"name":"organic substances, including","range":null},{"name":"inhalable fraction","range":null},{"name":"metals and their compounds, including","range":null},{"name":"inhalable fraction","range":null},{"name":"respirable fraction","range":null},{"name":"respirable asbestos fibres","range":null}],"search_en":"Workplace environment - air Air sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents inhalable fraction respirable fraction inorganic substances, including respirable fraction thoracic fraction organic substances, including inhalable fraction metals and their compounds, including inhalable fraction respirable fraction respirable asbestos fibres PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"粉尘因素","range":null},{"name":"可吸入组分","range":null},{"name":"呼吸性组分","range":null},{"name":"无机物质，包括","range":null},{"name":"呼吸性组分","range":null},{"name":"胸腔组分","range":null},{"name":"有机物质，包括","range":null},{"name":"可吸入组分","range":null},{"name":"金属及其化合物，包括","range":null},{"name":"可吸入组分","range":null},{"name":"呼吸性组分","range":null},{"name":"可吸入石棉纤维","range":null}],"search_zh":"工作场所环境 — 空气 职业接触评估空气采样，针对： 个体剂量测定法 粉尘因素 可吸入组分 呼吸性组分 无机物质，包括 呼吸性组分 胸腔组分 有机物质，包括 可吸入组分 金属及其化合物，包括 可吸入组分 呼吸性组分 可吸入石棉纤维 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"职业接触评估空气采样，针对："},{"_id":"6a832412884ede9a1b2c4f3b","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004","test_object_en":"Workplace environment - air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a832412884ede9a1b2c4f3c","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna","parameters":[{"name":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna","range":"(0,11 - 30) mg/m3"},{"name":"Asfalt naftowy","range":null},{"name":"Apatyty i fosforyty","range":null},{"name":"Cement portlandzki","range":null},{"name":"Ditlenek tytanu","range":null},{"name":"Grafit naturalny","range":null},{"name":"Grafit syntetyczny","range":null},{"name":"Kaolin","range":null},{"name":"Krzemionka bezpostaciowa i synte-tyczna","range":null},{"name":"Pyły drewna","range":null},{"name":"Pyły mąki","range":null},{"name":"Pyły niesklasyfikowane ze względu na toksyczność","range":null},{"name":"Pyły organiczne pochodzenia zwie-rzęcego i roślinnego z wyjątkiem py-łów drewna oraz mąki","range":null},{"name":"Siarczan (VI) wapnia (gips)","range":null},{"name":"Sadza techniczna","range":null},{"name":"Talk","range":null},{"name":"Węgiel (kamienny, brunatny)","range":null},{"name":"Węglan magnezu wapnia (dolomit)","range":null},{"name":"Węglik krzemu, niewłóknisty","range":null}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\nStężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna (0,11 - 30) mg/m3\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i synte-tyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwie-rzęcego i roślinnego z wyjątkiem py-łów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\nStężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna (0,11 - 30) mg/m3\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i synte-tyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwie-rzęcego i roślinnego z wyjątkiem py-łów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\nStezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna (0,11 - 30) mg/m3\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i synte-tyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwie-rzecego i roslinnego z wyjatkiem py-low drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – inhalable fraction","parameters_en":[{"name":"Concentration of harmful dust agents – inhalable fraction","range":"(0,11 - 30) mg/m3"},{"name":"Petroleum bitumen","range":null},{"name":"Apatites and phosphorites","range":null},{"name":"Portland cement","range":null},{"name":"Titanium dioxide","range":null},{"name":"Natural graphite","range":null},{"name":"Synthetic graphite","range":null},{"name":"Kaolin","range":null},{"name":"Amorphous and synthe-tic silica","range":null},{"name":"Wood dusts","range":null},{"name":"Flour dusts","range":null},{"name":"Dusts not classified according to toxicity","range":null},{"name":"Organic dusts of animal and plant origin, excluding wood dust and flour","range":null},{"name":"Calcium sulfate (VI) (gypsum)","range":null},{"name":"Carbon black","range":null},{"name":"Talc","range":null},{"name":"Coal (hard, brown)","range":null},{"name":"Calcium magnesium carbonate (dolomite)","range":null},{"name":"Silicon carbide, non-fibrous","range":null}],"search_en":"Workplace environment - air Concentration of harmful dust agents – inhalable fraction Gravimetric method Concentration of harmful dust agents – inhalable fraction Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthe-tic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood dust and flour Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"有害粉尘因素浓度 — 可吸入组分","range":"(0,11 - 30) mg/m3"},{"name":"石油沥青","range":null},{"name":"磷灰石与磷块岩","range":null},{"name":"硅酸盐水泥","range":null},{"name":"二氧化钛","range":null},{"name":"天然石墨","range":null},{"name":"合成石墨","range":null},{"name":"高岭土","range":null},{"name":"Krzemionka bezpostaciowa i synte-tyczna","range":null},{"name":"木粉尘","range":null},{"name":"面粉粉尘","range":null},{"name":"未按毒性分类的粉尘","range":null},{"name":"Pyły organiczne pochodzenia zwie-rzęcego i roślinnego z wyjątkiem py-łów drewna oraz mąki","range":null},{"name":"硫酸钙（VI）（石膏）","range":null},{"name":"炭黑","range":null},{"name":"滑石","range":null},{"name":"煤（烟煤、褐煤）","range":null},{"name":"碳酸钙镁（白云石）","range":null},{"name":"碳化硅，非纤维状","range":null}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分 重量法 有害粉尘因素浓度 — 可吸入组分 石油沥青 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 木粉尘 面粉粉尘 未按毒性分类的粉尘 硫酸钙（VI）（石膏） 炭黑 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分"},{"_id":"6a832412884ede9a1b2c4f3d","lab_id":"69ad52a3de79e566650fb93b","country":"PL","accr_number":"AB 1749","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodli-wych dla zdrowia – frakcja respirabilna","parameters":[{"name":"Stężenie pyłowych czynników szkodli-wych dla zdrowia – frakcja respirabilna","range":"(0,10 - 28) mg/m3"},{"name":"Apatyty i fosforyty","range":null},{"name":"Cement portlandzki","range":null},{"name":"Grafit naturalny","range":null},{"name":"Krzemionka bezpostaciowa i synte-tyczna","range":null},{"name":"Pyły organiczne pochodzenia zwie-rzęcego i roślinnego z wyjątkiem py-łów drewna oraz mąki","range":null},{"name":"Talk","range":null},{"name":"Węgiel (kamienny, brunatny)","range":null}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodli-wych dla zdrowia – frakcja respirabilna\nZakres:\nStężenie pyłowych czynników szkodli-wych dla zdrowia – frakcja respirabilna (0,10 - 28) mg/m3\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i synte-tyczna\nPyły organiczne pochodzenia zwie-rzęcego i roślinnego z wyjątkiem py-łów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Instytut Analiz Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodli-wych dla zdrowia – frakcja respirabilna\nZakres:\nStężenie pyłowych czynników szkodli-wych dla zdrowia – frakcja respirabilna (0,10 - 28) mg/m3\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i synte-tyczna\nPyły organiczne pochodzenia zwie-rzęcego i roślinnego z wyjątkiem py-łów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodli-wych dla zdrowia – frakcja respirabilna\nZakres:\nStezenie pylowych czynnikow szkodli-wych dla zdrowia – frakcja respirabilna (0,10 - 28) mg/m3\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i synte-tyczna\nPyly organiczne pochodzenia zwie-rzecego i roslinnego z wyjatkiem py-low drewna oraz maki\nTalk\nWegiel (kamienny, brunatny)\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – respirable fraction","parameters_en":[{"name":"Concentration of harmful dust agents – respirable fraction","range":"(0,10 - 28) mg/m3"},{"name":"Apatites and phosphorites","range":null},{"name":"Portland cement","range":null},{"name":"Natural graphite","range":null},{"name":"Amorphous and synthe-tic silica","range":null},{"name":"Organic dusts of animal and plant origin, excluding wood dust and flour","range":null},{"name":"Talc","range":null},{"name":"Coal (hard, brown)","range":null}],"search_en":"Workplace environment - air Concentration of harmful dust agents – respirable fraction Gravimetric method Concentration of harmful dust agents – respirable fraction Apatites and phosphorites Portland cement Natural graphite Amorphous and synthe-tic silica Organic dusts of animal and plant origin, excluding wood dust and flour Talc Coal (hard, brown) PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"Stężenie pyłowych czynników szkodli-wych dla zdrowia – frakcja respirabilna","range":"(0,10 - 28) mg/m3"},{"name":"磷灰石与磷块岩","range":null},{"name":"硅酸盐水泥","range":null},{"name":"天然石墨","range":null},{"name":"Krzemionka bezpostaciowa i synte-tyczna","range":null},{"name":"Pyły organiczne pochodzenia zwie-rzęcego i roślinnego z wyjątkiem py-łów drewna oraz mąki","range":null},{"name":"滑石","range":null},{"name":"煤（烟煤、褐煤）","range":null}],"search_zh":"工作场所环境 — 空气 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 滑石 煤（烟煤、褐煤） PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气"}],"has_pdf":true}