{"lab":{"_id":"69ad52a3de79e566650fb92d","accr_number":"AB 1741","country":"PL","accr_body":"PCA","address":"ul. Grunwaldzka 2 A, 48-340 Głuchołazy","categories":["electronics","materials"],"city":"Głuchołazy","imported_at":"2026-03-08T10:42:43.265Z","methods_count":3,"name":"Ośrodek Badawczo-Rozwojowy RCC Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1741.pdf"],"scope_summary":"","search_text":"ośrodek badawczo-rozwojowy rcc sp. z o.o. ul. grunwaldzka 2 a, 48-340 głuchołazy materials pharma electronics other","status":"active","updated_at":"2026-03-08T14:50:51.735Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:51.735Z","email_confidence":"high","email_mx":true,"email_source":"https://rcc.com.pl/en/kontakt/","fields_of_testing":[{"codes":"C/6; C/54","pl":"Badania chemiczne wyrobów i wyposażenia elektrycznego, wyrobów i wyposażenia elektronicznego","en":"Chemical tests of electrical and electronic products and equipment"},{"codes":"H/6; H/54","pl":"Badania ogniowe wyrobów i wyposażenia elektrycznego, wyrobów i wyposażenia elektronicznego","en":"Fire tests of electrical and electronic products and equipment"}],"issue":{"no":"7","date":"14.01.2025"},"parse_date":"2026-07-20T07:09:28.498Z","parse_source":"script-pdfplumber","map_coord":[50.319546,17.390998],"map_geo":"nominatim-street","has_en":true,"category_counts":{"electronics":3,"materials":2},"category_scores":{"electronics":1.8,"materials":0.8},"has_zh":true},"methods":[{"_id":"6a5dc9a8f1c10c8ce8259c61","lab_id":"69ad52a3de79e566650fb92d","country":"PL","accr_number":"AB 1741","accr_body":"PCA","test_object":"Materiały stosowane do produkcji sprzętu elektrycznego i elektronicznego: tworzywa sztuczne, wyroby z tworzyw sztucznych","test_object_en":"Materials used in the manufacture of electrical and electronic equipment: plastics, plastic products","methodology":"Zawartość pierwiastków, Zakres, Cd (50 – 150) mg/kg, Pb (300 – 1500) mg/kg, Hg (300 – 1500) mg/kg, Brcałk (50 – 500) mg/kg, Crcałk (300 – 1500) mg/kg","methodology_en":"Content of elements, Range, Cd (50 – 150) mg/kg, Pb (300 – 1500) mg/kg, Hg (300 – 1500) mg/kg, Brtotal (50 – 500) mg/kg, Crtotal (300 – 1500) mg/kg","parameters":[],"parameters_en":[],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (ED-XRF)","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (ED-XRF)"],"technique_en":"Energy-dispersive X-ray fluorescence spectrometry (ED-XRF)","computed":[],"computed_en":[],"activity":"Zawartość pierwiastków, Zakres, Cd (50 – 150) mg/kg, Pb (300 – 1500) mg/kg, Hg (300 – 1500) mg/kg, Brcałk (50 – 500) mg/kg, Crcałk (300 – 1500) mg/kg\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (ED-XRF)","reference":"PN-EN 62321-3-1:2014-08","norm_bases":["PN-EN 62321-3-1:2014-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały stosowane do produkcji sprzętu elektrycznego i elektronicznego: tworzywa sztuczne, wyroby z tworzyw sztucznych Zawartość pierwiastków, Zakres, Cd (50 – 150) mg/kg, Pb (300 – 1500) mg/kg, Hg (300 – 1500) mg/kg, Brcałk (50 – 500) mg/kg, Crcałk (300 – 1500) mg/kg\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (ED-XRF) PN-EN 62321-3-1:2014-08 Materialy stosowane do produkcji sprzetu elektrycznego i elektronicznego: tworzywa sztuczne, wyroby z tworzyw sztucznych Zawartosc pierwiastkow, Zakres, Cd (50 – 150) mg/kg, Pb (300 – 1500) mg/kg, Hg (300 – 1500) mg/kg, Brcalk (50 – 500) mg/kg, Crcalk (300 – 1500) mg/kg\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja energii (ED-XRF) PN-EN 62321-3-1:2014-08","categories":["materials","electronics"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Materials used in the manufacture of electrical and electronic equipment: plastics, plastic products Content of elements, Range, Cd (50 – 150) mg/kg, Pb (300 – 1500) mg/kg, Hg (300 – 1500) mg/kg, Brtotal (50 – 500) mg/kg, Crtotal (300 – 1500) mg/kg Energy-dispersive X-ray fluorescence spectrometry (ED-XRF) PN-EN 62321-3-1:2014-08","search_zh":"能量色散X射线荧光光谱法（ED-XRF） PN-EN 62321-3-1:2014-08","technique_zh":"能量色散X射线荧光光谱法（ED-XRF）"},{"_id":"6a5dc9a8f1c10c8ce8259c62","lab_id":"69ad52a3de79e566650fb92d","country":"PL","accr_number":"AB 1741","accr_body":"PCA","test_object":"Materiały stosowane do produkcji sprzętu elektrycznego i elektronicznego: Metale, wyroby ze stopów metali","test_object_en":"Materials used in the manufacture of electrical and electronic equipment: Metals, metal alloy products","methodology":"Zawartość pierwiastków, Zakres, Cd (50 – 150) mg/kg, Pb (300 – 1500) mg/kg, Hg (300 – 1500) mg/kg, Crcałk (300 – 1500) mg/kg","methodology_en":"Content of elements, Range, Cd (50 – 150) mg/kg, Pb (300 – 1500) mg/kg, Hg (300 – 1500) mg/kg, Crtotal (300 – 1500) mg/kg","parameters":[],"parameters_en":[],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (ED-XRF)","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (ED-XRF)"],"technique_en":"Energy-dispersive X-ray fluorescence spectrometry (ED-XRF)","computed":[],"computed_en":[],"activity":"Zawartość pierwiastków, Zakres, Cd (50 – 150) mg/kg, Pb (300 – 1500) mg/kg, Hg (300 – 1500) mg/kg, Crcałk (300 – 1500) mg/kg\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (ED-XRF)","reference":"PN-EN 62321-3-1:2014-08","norm_bases":["PN-EN 62321-3-1:2014-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały stosowane do produkcji sprzętu elektrycznego i elektronicznego: Metale, wyroby ze stopów metali Zawartość pierwiastków, Zakres, Cd (50 – 150) mg/kg, Pb (300 – 1500) mg/kg, Hg (300 – 1500) mg/kg, Crcałk (300 – 1500) mg/kg\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (ED-XRF) PN-EN 62321-3-1:2014-08 Materialy stosowane do produkcji sprzetu elektrycznego i elektronicznego: Metale, wyroby ze stopow metali Zawartosc pierwiastkow, Zakres, Cd (50 – 150) mg/kg, Pb (300 – 1500) mg/kg, Hg (300 – 1500) mg/kg, Crcalk (300 – 1500) mg/kg\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja energii (ED-XRF) PN-EN 62321-3-1:2014-08","categories":["materials","electronics"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Materials used in the manufacture of electrical and electronic equipment: Metals, metal alloy products Content of elements, Range, Cd (50 – 150) mg/kg, Pb (300 – 1500) mg/kg, Hg (300 – 1500) mg/kg, Crtotal (300 – 1500) mg/kg Energy-dispersive X-ray fluorescence spectrometry (ED-XRF) PN-EN 62321-3-1:2014-08","search_zh":"能量色散X射线荧光光谱法（ED-XRF） PN-EN 62321-3-1:2014-08","technique_zh":"能量色散X射线荧光光谱法（ED-XRF）"},{"_id":"6a5dc9a8f1c10c8ce8259c63","lab_id":"69ad52a3de79e566650fb92d","country":"PL","accr_number":"AB 1741","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne i elektroniczne","test_object_en":"Electrical and electronic products and equipment","methodology":"Odporność na gorąco (próba wciskania kulki)","methodology_en":"Resistance to heat (ball pressure test)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na gorąco (próba wciskania kulki)","reference":"PN-EN 60695-10-2:2014-10 | PN-EN IEC 60598-1:2021-07 pkt 13.2 | PN-EN IEC 60598-1:2021-07/A11:2022-12","norm_bases":["PN-EN 60695-10-2:2014-10","PN-EN IEC 60598-1:2021-07 pkt 13.2","PN-EN IEC 60598-1:2021-07/A11:2022-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne i elektroniczne Odporność na gorąco (próba wciskania kulki) PN-EN 60695-10-2:2014-10 | PN-EN IEC 60598-1:2021-07 pkt 13.2 | PN-EN IEC 60598-1:2021-07/A11:2022-12 Wyroby i wyposazenie elektryczne i elektroniczne Odpornosc na goraco (proba wciskania kulki) PN-EN 60695-10-2:2014-10 | PN-EN IEC 60598-1:2021-07 pkt 13.2 | PN-EN IEC 60598-1:2021-07/A11:2022-12","categories":["electronics"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and electronic products and equipment Resistance to heat (ball pressure test) PN-EN 60695-10-2:2014-10 | PN-EN IEC 60598-1:2021-07 pkt 13.2 | PN-EN IEC 60598-1:2021-07/A11:2022-12"}],"has_pdf":true}