{"lab":{"_id":"69ad52a3de79e566650fb92b","accr_number":"AB 1740","country":"PL","accr_body":"PCA","address":"Krąg 4A, 83-200 Starogard Gdański, LABORATORIUM KONTROLI JAKOŚCI, ul. Leśna 1, Owidz","categories":["microbiology"],"city":"Starogard Gdański","imported_at":"2026-03-08T10:42:43.265Z","methods_count":21,"name":"GRASO ZS SPÓŁKA Z OGRANICZONĄ ODPOWIEDZIALNOŚCIĄ","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1740.pdf"],"scope_summary":"","search_text":"graso zs spółka z ograniczoną odpowiedzialnością krąg 4a, 83-200 starogard gdański, laboratorium kontroli jakości, ul. leśna 1, owidz pharma other microbiology automotive food","status":"active","updated_at":"2026-03-08T14:50:51.683Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:51.683Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201740,podmiot.html","fields_of_testing":[{"codes":"K/17","pl":"Badania mikrobiologiczne wyrobów innych","en":"Microbiological tests of other products"}],"issue":{"no":"4","date":"26.01.2026"},"parse_date":"2026-07-20T07:09:28.471Z","parse_source":"script-pdfplumber","map_coord":[53.983973,18.53765],"map_geo":"nominatim-street","has_en":true,"category_counts":{"microbiology":15,"other":5,"water":1},"category_scores":{"microbiology":10.71,"other":1.19,"water":0.05},"has_zh":true},"methods":[{"_id":"6a5dc9a8f1c10c8ce8259c4c","lab_id":"69ad52a3de79e566650fb92b","country":"PL","accr_number":"AB 1740","accr_body":"PCA","test_object":"Pożywka stała agarowa selektywna do izolowania i wykrywania drobnoustrojów: MACCONKEY AGAR ENTEROCOCCOSEL AGAR (BILE ESCULIN AZIDE AGAR) YERSINIA CIN AGAR COLUMBIA AGAR Z KRWIĄ BARANIĄ I ANTYBIOTYKAMI SABOURAUD DEXTROSE AGAR Z ANTYBIOTYKAMI PALCAM AGAR HAEMOPHILUS CHOCOLATE AGAR BGA CETRIMIDE AGAR CHROMAGAR STEC CHROMAGAR CAMPYLOBACTER CHROMAGAR MRSA CHROMAGAR CANDIDA CHROMAGAR STAPHYLOCOCCUS AUREUS XLD AGAR CHROMAGAR VIBRIO CHROMAGAR VRE CHROMAGAR ESBL CHROMAGAR KPC CHROMAGAR ACINETOBACTER CHROMAGAR Y.ENTEROCOLITICA KARMALI AGAR MALT EXTRACT AGAR Z ANTYBIOTYKAMI","test_object_en":"Selective solid agar medium for the isolation and detection of microorganisms: MACCONKEY AGAR ENTEROCOCCOSEL AGAR (BILE ESCULIN AZIDE AGAR) YERSINIA CIN AGAR COLUMBIA AGAR WITH SHEEP BLOOD AND ANTIBIOTICS SABOURAUD DEXTROSE AGAR WITH ANTIBIOTICS PALCAM AGAR HAEMOPHILUS CHOCOLATE AGAR BGA CETRIMIDE AGAR CHROMAGAR STEC CHROMAGAR CAMPYLOBACTER CHROMAGAR MRSA CHROMAGAR CANDIDA CHROMAGAR STAPHYLOCOCCUS AUREUS XLD AGAR CHROMAGAR VIBRIO CHROMAGAR VRE CHROMAGAR ESBL CHROMAGAR KPC CHROMAGAR ACINETOBACTER CHROMAGAR Y.ENTEROCOLITICA KARMALI AGAR MALT EXTRACT AGAR WITH ANTIBIOTICS","methodology":"Żyzność","methodology_en":"Fertility","parameters":[],"parameters_en":[],"technique":"Metoda jakościowa, płytkowa (posiew rysowy, redukcyjny)","techniques":["Metoda jakościowa, płytkowa (posiew rysowy, redukcyjny)"],"technique_en":"Qualitative plate method (streak plate, reductive streak)","computed":[],"computed_en":[],"activity":"Żyzność\nMetoda jakościowa, płytkowa (posiew rysowy, redukcyjny)","reference":"PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","norm_bases":["PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pożywka stała agarowa selektywna do izolowania i wykrywania drobnoustrojów: MACCONKEY AGAR ENTEROCOCCOSEL AGAR (BILE ESCULIN AZIDE AGAR) YERSINIA CIN AGAR COLUMBIA AGAR Z KRWIĄ BARANIĄ I ANTYBIOTYKAMI SABOURAUD DEXTROSE AGAR Z ANTYBIOTYKAMI PALCAM AGAR HAEMOPHILUS CHOCOLATE AGAR BGA CETRIMIDE AGAR CHROMAGAR STEC CHROMAGAR CAMPYLOBACTER CHROMAGAR MRSA CHROMAGAR CANDIDA CHROMAGAR STAPHYLOCOCCUS AUREUS XLD AGAR CHROMAGAR VIBRIO CHROMAGAR VRE CHROMAGAR ESBL CHROMAGAR KPC CHROMAGAR ACINETOBACTER CHROMAGAR Y.ENTEROCOLITICA KARMALI AGAR MALT EXTRACT AGAR Z ANTYBIOTYKAMI Żyzność\nMetoda jakościowa, płytkowa (posiew rysowy, redukcyjny) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019 Pozywka stala agarowa selektywna do izolowania i wykrywania drobnoustrojow: MACCONKEY AGAR ENTEROCOCCOSEL AGAR (BILE ESCULIN AZIDE AGAR) YERSINIA CIN AGAR COLUMBIA AGAR Z KRWIA BARANIA I ANTYBIOTYKAMI SABOURAUD DEXTROSE AGAR Z ANTYBIOTYKAMI PALCAM AGAR HAEMOPHILUS CHOCOLATE AGAR BGA CETRIMIDE AGAR CHROMAGAR STEC CHROMAGAR CAMPYLOBACTER CHROMAGAR MRSA CHROMAGAR CANDIDA CHROMAGAR STAPHYLOCOCCUS AUREUS XLD AGAR CHROMAGAR VIBRIO CHROMAGAR VRE CHROMAGAR ESBL CHROMAGAR KPC CHROMAGAR ACINETOBACTER CHROMAGAR Y.ENTEROCOLITICA KARMALI AGAR MALT EXTRACT AGAR Z ANTYBIOTYKAMI Zyznosc\nMetoda jakosciowa, plytkowa (posiew rysowy, redukcyjny) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","categories":["microbiology"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Selective solid agar medium for the isolation and detection of microorganisms: MACCONKEY AGAR ENTEROCOCCOSEL AGAR (BILE ESCULIN AZIDE AGAR) YERSINIA CIN AGAR COLUMBIA AGAR WITH SHEEP BLOOD AND ANTIBIOTICS SABOURAUD DEXTROSE AGAR WITH ANTIBIOTICS PALCAM AGAR HAEMOPHILUS CHOCOLATE AGAR BGA CETRIMIDE AGAR CHROMAGAR STEC CHROMAGAR CAMPYLOBACTER CHROMAGAR MRSA CHROMAGAR CANDIDA CHROMAGAR STAPHYLOCOCCUS AUREUS XLD AGAR CHROMAGAR VIBRIO CHROMAGAR VRE CHROMAGAR ESBL CHROMAGAR KPC CHROMAGAR ACINETOBACTER CHROMAGAR Y.ENTEROCOLITICA KARMALI AGAR MALT EXTRACT AGAR WITH ANTIBIOTICS Fertility Qualitative plate method (streak plate, reductive streak) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","methodology_zh":"肥力","search_zh":"肥力 定性平板法（划线、稀释接种） PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","technique_zh":"定性平板法（划线、稀释接种）"},{"_id":"6a5dc9a8f1c10c8ce8259c4d","lab_id":"69ad52a3de79e566650fb92b","country":"PL","accr_number":"AB 1740","accr_body":"PCA","test_object":"Pożywka stała agarowa selektywna do izolowania i wykrywania drobnoustrojów: MACCONKEY AGAR ENTEROCOCCOSEL AGAR (BILE ESCULIN AZIDE AGAR) YERSINIA CIN AGAR COLUMBIA AGAR Z KRWIĄ BARANIĄ I ANTYBIOTYKAMI SABOURAUD DEXTROSE AGAR Z ANTYBIOTYKAMI PALCAM AGAR HAEMOPHILUS CHOCOLATE AGAR BGA CETRIMIDE AGAR CHROMAGAR STEC CHROMAGAR CAMPYLOBACTER CHROMAGAR MRSA CHROMAGAR CANDIDA CHROMAGAR STAPHYLOCOCCUS AUREUS XLD AGAR CHROMAGAR VIBRIO CHROMAGAR VRE CHROMAGAR ESBL CHROMAGAR KPC CHROMAGAR ACINETOBACTER CHROMAGAR Y.ENTEROCOLITICA KARMALI AGAR MALT EXTRACT AGAR Z ANTYBIOTYKAMI","test_object_en":"Selective solid agar medium for the isolation and detection of microorganisms: MACCONKEY AGAR ENTEROCOCCOSEL AGAR (BILE ESCULIN AZIDE AGAR) YERSINIA CIN AGAR COLUMBIA AGAR WITH SHEEP BLOOD AND ANTIBIOTICS SABOURAUD DEXTROSE AGAR WITH ANTIBIOTICS PALCAM AGAR HAEMOPHILUS CHOCOLATE AGAR BGA CETRIMIDE AGAR CHROMAGAR STEC CHROMAGAR CAMPYLOBACTER CHROMAGAR MRSA CHROMAGAR CANDIDA CHROMAGAR STAPHYLOCOCCUS AUREUS XLD AGAR CHROMAGAR VIBRIO CHROMAGAR VRE CHROMAGAR ESBL CHROMAGAR KPC CHROMAGAR ACINETOBACTER CHROMAGAR Y.ENTEROCOLITICA KARMALI AGAR MALT EXTRACT AGAR WITH ANTIBIOTICS","methodology":"Selektywność","methodology_en":"Selectivity","parameters":[],"parameters_en":[],"technique":"Metoda jakościowa, płytkowa (posiew rysowy)","techniques":["Metoda jakościowa, płytkowa (posiew rysowy)"],"technique_en":"Qualitative plate method (streak plate)","computed":[],"computed_en":[],"activity":"Selektywność\nMetoda jakościowa, płytkowa (posiew rysowy)","reference":"PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","norm_bases":["PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pożywka stała agarowa selektywna do izolowania i wykrywania drobnoustrojów: MACCONKEY AGAR ENTEROCOCCOSEL AGAR (BILE ESCULIN AZIDE AGAR) YERSINIA CIN AGAR COLUMBIA AGAR Z KRWIĄ BARANIĄ I ANTYBIOTYKAMI SABOURAUD DEXTROSE AGAR Z ANTYBIOTYKAMI PALCAM AGAR HAEMOPHILUS CHOCOLATE AGAR BGA CETRIMIDE AGAR CHROMAGAR STEC CHROMAGAR CAMPYLOBACTER CHROMAGAR MRSA CHROMAGAR CANDIDA CHROMAGAR STAPHYLOCOCCUS AUREUS XLD AGAR CHROMAGAR VIBRIO CHROMAGAR VRE CHROMAGAR ESBL CHROMAGAR KPC CHROMAGAR ACINETOBACTER CHROMAGAR Y.ENTEROCOLITICA KARMALI AGAR MALT EXTRACT AGAR Z ANTYBIOTYKAMI Selektywność\nMetoda jakościowa, płytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019 Pozywka stala agarowa selektywna do izolowania i wykrywania drobnoustrojow: MACCONKEY AGAR ENTEROCOCCOSEL AGAR (BILE ESCULIN AZIDE AGAR) YERSINIA CIN AGAR COLUMBIA AGAR Z KRWIA BARANIA I ANTYBIOTYKAMI SABOURAUD DEXTROSE AGAR Z ANTYBIOTYKAMI PALCAM AGAR HAEMOPHILUS CHOCOLATE AGAR BGA CETRIMIDE AGAR CHROMAGAR STEC CHROMAGAR CAMPYLOBACTER CHROMAGAR MRSA CHROMAGAR CANDIDA CHROMAGAR STAPHYLOCOCCUS AUREUS XLD AGAR CHROMAGAR VIBRIO CHROMAGAR VRE CHROMAGAR ESBL CHROMAGAR KPC CHROMAGAR ACINETOBACTER CHROMAGAR Y.ENTEROCOLITICA KARMALI AGAR MALT EXTRACT AGAR Z ANTYBIOTYKAMI Selektywnosc\nMetoda jakosciowa, plytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","categories":["microbiology"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Selective solid agar medium for the isolation and detection of microorganisms: MACCONKEY AGAR ENTEROCOCCOSEL AGAR (BILE ESCULIN AZIDE AGAR) YERSINIA CIN AGAR COLUMBIA AGAR WITH SHEEP BLOOD AND ANTIBIOTICS SABOURAUD DEXTROSE AGAR WITH ANTIBIOTICS PALCAM AGAR HAEMOPHILUS CHOCOLATE AGAR BGA CETRIMIDE AGAR CHROMAGAR STEC CHROMAGAR CAMPYLOBACTER CHROMAGAR MRSA CHROMAGAR CANDIDA CHROMAGAR STAPHYLOCOCCUS AUREUS XLD AGAR CHROMAGAR VIBRIO CHROMAGAR VRE CHROMAGAR ESBL CHROMAGAR KPC CHROMAGAR ACINETOBACTER CHROMAGAR Y.ENTEROCOLITICA KARMALI AGAR MALT EXTRACT AGAR WITH ANTIBIOTICS Selectivity Qualitative plate method (streak plate) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","methodology_zh":"选择性","search_zh":"选择性 定性平板法（划线接种） PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","technique_zh":"定性平板法（划线接种）"},{"_id":"6a5dc9a8f1c10c8ce8259c4e","lab_id":"69ad52a3de79e566650fb92b","country":"PL","accr_number":"AB 1740","accr_body":"PCA","test_object":"Pożywka stała agarowa selektywna do izolowania i wykrywania drobnoustrojów: SALMONELLA SHIGELLA AGAR CHROMAGAR SALMONELLA PLUS","test_object_en":"Selective solid agar medium for isolation and detection of microorganisms: SALMONELLA SHIGELLA AGAR CHROMAGAR SALMONELLA PLUS","methodology":"Żyzność","methodology_en":"Fertility","parameters":[],"parameters_en":[],"technique":"Metoda jakościowa, płytkowa (posiew rysowy, redukcyjny)","techniques":["Metoda jakościowa, płytkowa (posiew rysowy, redukcyjny)"],"technique_en":"Qualitative plate method (streak plate, reductive streak)","computed":[],"computed_en":[],"activity":"Żyzność\nMetoda jakościowa, płytkowa (posiew rysowy, redukcyjny)","reference":"PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","norm_bases":["PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pożywka stała agarowa selektywna do izolowania i wykrywania drobnoustrojów: SALMONELLA SHIGELLA AGAR CHROMAGAR SALMONELLA PLUS Żyzność\nMetoda jakościowa, płytkowa (posiew rysowy, redukcyjny) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019 Pozywka stala agarowa selektywna do izolowania i wykrywania drobnoustrojow: SALMONELLA SHIGELLA AGAR CHROMAGAR SALMONELLA PLUS Zyznosc\nMetoda jakosciowa, plytkowa (posiew rysowy, redukcyjny) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","categories":["microbiology"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Selective solid agar medium for isolation and detection of microorganisms: SALMONELLA SHIGELLA AGAR CHROMAGAR SALMONELLA PLUS Fertility Qualitative plate method (streak plate, reductive streak) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","methodology_zh":"肥力","search_zh":"用于分离与检出微生物的选择性固体琼脂培养基：SALMONELLA SHIGELLA AGAR、CHROMAGAR SALMONELLA PLUS 肥力 定性平板法（划线、稀释接种） PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","technique_zh":"定性平板法（划线、稀释接种）","test_object_zh":"用于分离与检出微生物的选择性固体琼脂培养基：SALMONELLA SHIGELLA AGAR、CHROMAGAR SALMONELLA PLUS"},{"_id":"6a5dc9a8f1c10c8ce8259c4f","lab_id":"69ad52a3de79e566650fb92b","country":"PL","accr_number":"AB 1740","accr_body":"PCA","test_object":"Pożywka stała agarowa selektywna do izolowania i wykrywania drobnoustrojów: SALMONELLA SHIGELLA AGAR CHROMAGAR SALMONELLA PLUS","test_object_en":"Selective solid agar medium for isolation and detection of microorganisms: SALMONELLA SHIGELLA AGAR CHROMAGAR SALMONELLA PLUS","methodology":"Selektywność","methodology_en":"Selectivity","parameters":[],"parameters_en":[],"technique":"Metoda jakościowa, płytkowa (posiew rysowy)","techniques":["Metoda jakościowa, płytkowa (posiew rysowy)"],"technique_en":"Qualitative plate method (streak plate)","computed":[],"computed_en":[],"activity":"Selektywność\nMetoda jakościowa, płytkowa (posiew rysowy)","reference":"PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","norm_bases":["PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pożywka stała agarowa selektywna do izolowania i wykrywania drobnoustrojów: SALMONELLA SHIGELLA AGAR CHROMAGAR SALMONELLA PLUS Selektywność\nMetoda jakościowa, płytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019 Pozywka stala agarowa selektywna do izolowania i wykrywania drobnoustrojow: SALMONELLA SHIGELLA AGAR CHROMAGAR SALMONELLA PLUS Selektywnosc\nMetoda jakosciowa, plytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","categories":["microbiology"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Selective solid agar medium for isolation and detection of microorganisms: SALMONELLA SHIGELLA AGAR CHROMAGAR SALMONELLA PLUS Selectivity Qualitative plate method (streak plate) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","methodology_zh":"选择性","search_zh":"用于分离与检出微生物的选择性固体琼脂培养基：SALMONELLA SHIGELLA AGAR、CHROMAGAR SALMONELLA PLUS 选择性 定性平板法（划线接种） PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","technique_zh":"定性平板法（划线接种）","test_object_zh":"用于分离与检出微生物的选择性固体琼脂培养基：SALMONELLA SHIGELLA AGAR、CHROMAGAR SALMONELLA PLUS"},{"_id":"6a5dc9a8f1c10c8ce8259c50","lab_id":"69ad52a3de79e566650fb92b","country":"PL","accr_number":"AB 1740","accr_body":"PCA","test_object":"Pożywka stała agarowa selektywna do izolowania i wykrywania drobnoustrojów: SALMONELLA SHIGELLA AGAR CHROMAGAR SALMONELLA PLUS","test_object_en":"Selective solid agar medium for isolation and detection of microorganisms: SALMONELLA SHIGELLA AGAR CHROMAGAR SALMONELLA PLUS","methodology":"Specyficzność","methodology_en":"Specificity","parameters":[],"parameters_en":[],"technique":"Metoda jakościowa, płytkowa (posiew rysowy)","techniques":["Metoda jakościowa, płytkowa (posiew rysowy)"],"technique_en":"Qualitative plate method (streak plate)","computed":[],"computed_en":[],"activity":"Specyficzność\nMetoda jakościowa, płytkowa (posiew rysowy)","reference":"PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","norm_bases":["PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pożywka stała agarowa selektywna do izolowania i wykrywania drobnoustrojów: SALMONELLA SHIGELLA AGAR CHROMAGAR SALMONELLA PLUS Specyficzność\nMetoda jakościowa, płytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019 Pozywka stala agarowa selektywna do izolowania i wykrywania drobnoustrojow: SALMONELLA SHIGELLA AGAR CHROMAGAR SALMONELLA PLUS Specyficznosc\nMetoda jakosciowa, plytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","categories":["microbiology"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Selective solid agar medium for isolation and detection of microorganisms: SALMONELLA SHIGELLA AGAR CHROMAGAR SALMONELLA PLUS Specificity Qualitative plate method (streak plate) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","search_zh":"用于分离与检出微生物的选择性固体琼脂培养基：SALMONELLA SHIGELLA AGAR、CHROMAGAR SALMONELLA PLUS 特异性 定性平板法（划线接种） PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","technique_zh":"定性平板法（划线接种）","methodology_zh":"特异性","test_object_zh":"用于分离与检出微生物的选择性固体琼脂培养基：SALMONELLA SHIGELLA AGAR、CHROMAGAR SALMONELLA PLUS"},{"_id":"6a5dc9a8f1c10c8ce8259c51","lab_id":"69ad52a3de79e566650fb92b","country":"PL","accr_number":"AB 1740","accr_body":"PCA","test_object":"Pożywka stała agarowa do izolowania i wykrywania drobnoustrojów: MH AGAR MH AGAR Z KRWIĄ CHOCOLATE AGAR Z POLYVITEX SCHAEDLER AGAR Z KRWIĄ BARANIĄ SABOURAUD DEXTROSE AGAR","test_object_en":"Solid agar medium for the isolation and detection of microorganisms: MH AGAR MH AGAR WITH BLOOD CHOCOLATE AGAR WITH POLYVITEX SCHAEDLER AGAR WITH SHEEP BLOOD SABOURAUD DEXTROSE AGAR","methodology":"Żyzność","methodology_en":"Fertility","parameters":[],"parameters_en":[],"technique":"Metoda jakościowa, płytkowa (posiew rysowy, redukcyjny)","techniques":["Metoda jakościowa, płytkowa (posiew rysowy, redukcyjny)"],"technique_en":"Qualitative plate method (streak plate, reductive streak)","computed":[],"computed_en":[],"activity":"Żyzność\nMetoda jakościowa, płytkowa (posiew rysowy, redukcyjny)","reference":"PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","norm_bases":["PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pożywka stała agarowa do izolowania i wykrywania drobnoustrojów: MH AGAR MH AGAR Z KRWIĄ CHOCOLATE AGAR Z POLYVITEX SCHAEDLER AGAR Z KRWIĄ BARANIĄ SABOURAUD DEXTROSE AGAR Żyzność\nMetoda jakościowa, płytkowa (posiew rysowy, redukcyjny) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019 Pozywka stala agarowa do izolowania i wykrywania drobnoustrojow: MH AGAR MH AGAR Z KRWIA CHOCOLATE AGAR Z POLYVITEX SCHAEDLER AGAR Z KRWIA BARANIA SABOURAUD DEXTROSE AGAR Zyznosc\nMetoda jakosciowa, plytkowa (posiew rysowy, redukcyjny) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","categories":["microbiology"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid agar medium for the isolation and detection of microorganisms: MH AGAR MH AGAR WITH BLOOD CHOCOLATE AGAR WITH POLYVITEX SCHAEDLER AGAR WITH SHEEP BLOOD SABOURAUD DEXTROSE AGAR Fertility Qualitative plate method (streak plate, reductive streak) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","methodology_zh":"肥力","search_zh":"肥力 定性平板法（划线、稀释接种） PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","technique_zh":"定性平板法（划线、稀释接种）"},{"_id":"6a5dc9a8f1c10c8ce8259c52","lab_id":"69ad52a3de79e566650fb92b","country":"PL","accr_number":"AB 1740","accr_body":"PCA","test_object":"Pożywka stała agarowa selektywna do oznaczania liczby drobnoustrojów: MYP AGAR BAIRD PARKER AGAR ALOA AGAR","test_object_en":"Selective solid agar medium for enumeration of microorganisms: MYP AGAR BAIRD PARKER AGAR ALOA AGAR","methodology":"Żyzność","methodology_en":"Fertility","parameters":[],"parameters_en":[],"technique":"Metoda ilościowa, płytkowa (posiew powierzchniowy)","techniques":["Metoda ilościowa, płytkowa (posiew powierzchniowy)"],"technique_en":"Quantitative plate method (spread plate)","computed":[],"computed_en":[],"activity":"Żyzność\nMetoda ilościowa, płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","norm_bases":["PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pożywka stała agarowa selektywna do oznaczania liczby drobnoustrojów: MYP AGAR BAIRD PARKER AGAR ALOA AGAR Żyzność\nMetoda ilościowa, płytkowa (posiew powierzchniowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019 Pozywka stala agarowa selektywna do oznaczania liczby drobnoustrojow: MYP AGAR BAIRD PARKER AGAR ALOA AGAR Zyznosc\nMetoda ilosciowa, plytkowa (posiew powierzchniowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","categories":["microbiology"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Selective solid agar medium for enumeration of microorganisms: MYP AGAR BAIRD PARKER AGAR ALOA AGAR Fertility Quantitative plate method (spread plate) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","methodology_zh":"肥力","search_zh":"用于微生物计数的选择性固体琼脂培养基：MYP AGAR、BAIRD PARKER AGAR、ALOA AGAR 肥力 定量平板法（表面涂布） PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","technique_zh":"定量平板法（表面涂布）","test_object_zh":"用于微生物计数的选择性固体琼脂培养基：MYP AGAR、BAIRD PARKER AGAR、ALOA AGAR"},{"_id":"6a5dc9a8f1c10c8ce8259c53","lab_id":"69ad52a3de79e566650fb92b","country":"PL","accr_number":"AB 1740","accr_body":"PCA","test_object":"Pożywka stała agarowa selektywna do oznaczania liczby drobnoustrojów: MYP AGAR BAIRD PARKER AGAR ALOA AGAR","test_object_en":"Selective solid agar medium for enumeration of microorganisms: MYP AGAR BAIRD PARKER AGAR ALOA AGAR","methodology":"Selektywność","methodology_en":"Selectivity","parameters":[],"parameters_en":[],"technique":"Metoda jakościowa, płytkowa (posiew rysowy)","techniques":["Metoda jakościowa, płytkowa (posiew rysowy)"],"technique_en":"Qualitative plate method (streak plate)","computed":[],"computed_en":[],"activity":"Selektywność\nMetoda jakościowa, płytkowa (posiew rysowy)","reference":"PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","norm_bases":["PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pożywka stała agarowa selektywna do oznaczania liczby drobnoustrojów: MYP AGAR BAIRD PARKER AGAR ALOA AGAR Selektywność\nMetoda jakościowa, płytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019 Pozywka stala agarowa selektywna do oznaczania liczby drobnoustrojow: MYP AGAR BAIRD PARKER AGAR ALOA AGAR Selektywnosc\nMetoda jakosciowa, plytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","categories":["microbiology"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Selective solid agar medium for enumeration of microorganisms: MYP AGAR BAIRD PARKER AGAR ALOA AGAR Selectivity Qualitative plate method (streak plate) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","methodology_zh":"选择性","search_zh":"用于微生物计数的选择性固体琼脂培养基：MYP AGAR、BAIRD PARKER AGAR、ALOA AGAR 选择性 定性平板法（划线接种） PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","technique_zh":"定性平板法（划线接种）","test_object_zh":"用于微生物计数的选择性固体琼脂培养基：MYP AGAR、BAIRD PARKER AGAR、ALOA AGAR"},{"_id":"6a5dc9a8f1c10c8ce8259c54","lab_id":"69ad52a3de79e566650fb92b","country":"PL","accr_number":"AB 1740","accr_body":"PCA","test_object":"Pożywka stała agarowa selektywna do oznaczania liczby drobnoustrojów: MYP AGAR BAIRD PARKER AGAR ALOA AGAR","test_object_en":"Selective solid agar medium for enumeration of microorganisms: MYP AGAR BAIRD PARKER AGAR ALOA AGAR","methodology":"Specyficzność","methodology_en":"Specificity","parameters":[],"parameters_en":[],"technique":"Metoda jakościowa, płytkowa (posiew rysowy)","techniques":["Metoda jakościowa, płytkowa (posiew rysowy)"],"technique_en":"Qualitative plate method (streak plate)","computed":[],"computed_en":[],"activity":"Specyficzność\nMetoda jakościowa, płytkowa (posiew rysowy)","reference":"PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","norm_bases":["PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pożywka stała agarowa selektywna do oznaczania liczby drobnoustrojów: MYP AGAR BAIRD PARKER AGAR ALOA AGAR Specyficzność\nMetoda jakościowa, płytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019 Pozywka stala agarowa selektywna do oznaczania liczby drobnoustrojow: MYP AGAR BAIRD PARKER AGAR ALOA AGAR Specyficznosc\nMetoda jakosciowa, plytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","categories":["microbiology"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Selective solid agar medium for enumeration of microorganisms: MYP AGAR BAIRD PARKER AGAR ALOA AGAR Specificity Qualitative plate method (streak plate) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","search_zh":"用于微生物计数的选择性固体琼脂培养基：MYP AGAR、BAIRD PARKER AGAR、ALOA AGAR 特异性 定性平板法（划线接种） PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","technique_zh":"定性平板法（划线接种）","methodology_zh":"特异性","test_object_zh":"用于微生物计数的选择性固体琼脂培养基：MYP AGAR、BAIRD PARKER AGAR、ALOA AGAR"},{"_id":"6a5dc9a8f1c10c8ce8259c55","lab_id":"69ad52a3de79e566650fb92b","country":"PL","accr_number":"AB 1740","accr_body":"PCA","test_object":"Pożywka stała agarowa selektywna do oznaczania liczby drobnoustrojów: LACTOBACILLI MRS AGAR DRBC AGAR MANNITOL SALT AGAR PSEUDOMONAS CFC AGAR","test_object_en":"Selective solid agar medium for the enumeration of microorganisms: LACTOBACILLI MRS AGAR DRBC AGAR MANNITOL SALT AGAR PSEUDOMONAS CFC AGAR","methodology":"Żyzność","methodology_en":"Fertility","parameters":[],"parameters_en":[],"technique":"Metoda ilościowa, płytkowa (posiew powierzchniowy)","techniques":["Metoda ilościowa, płytkowa (posiew powierzchniowy)"],"technique_en":"Quantitative plate method (spread plate)","computed":[],"computed_en":[],"activity":"Żyzność\nMetoda ilościowa, płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","norm_bases":["PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pożywka stała agarowa selektywna do oznaczania liczby drobnoustrojów: LACTOBACILLI MRS AGAR DRBC AGAR MANNITOL SALT AGAR PSEUDOMONAS CFC AGAR Żyzność\nMetoda ilościowa, płytkowa (posiew powierzchniowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019 Pozywka stala agarowa selektywna do oznaczania liczby drobnoustrojow: LACTOBACILLI MRS AGAR DRBC AGAR MANNITOL SALT AGAR PSEUDOMONAS CFC AGAR Zyznosc\nMetoda ilosciowa, plytkowa (posiew powierzchniowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","categories":["microbiology"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Selective solid agar medium for the enumeration of microorganisms: LACTOBACILLI MRS AGAR DRBC AGAR MANNITOL SALT AGAR PSEUDOMONAS CFC AGAR Fertility Quantitative plate method (spread plate) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","methodology_zh":"肥力","search_zh":"肥力 定量平板法（表面涂布） PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","technique_zh":"定量平板法（表面涂布）"},{"_id":"6a5dc9a8f1c10c8ce8259c56","lab_id":"69ad52a3de79e566650fb92b","country":"PL","accr_number":"AB 1740","accr_body":"PCA","test_object":"Pożywka stała agarowa selektywna do oznaczania liczby drobnoustrojów: LACTOBACILLI MRS AGAR DRBC AGAR MANNITOL SALT AGAR PSEUDOMONAS CFC AGAR","test_object_en":"Selective solid agar medium for the enumeration of microorganisms: LACTOBACILLI MRS AGAR DRBC AGAR MANNITOL SALT AGAR PSEUDOMONAS CFC AGAR","methodology":"Selektywność","methodology_en":"Selectivity","parameters":[],"parameters_en":[],"technique":"Metoda jakościowa, płytkowa (posiew rysowy)","techniques":["Metoda jakościowa, płytkowa (posiew rysowy)"],"technique_en":"Qualitative plate method (streak plate)","computed":[],"computed_en":[],"activity":"Selektywność\nMetoda jakościowa, płytkowa (posiew rysowy)","reference":"PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","norm_bases":["PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pożywka stała agarowa selektywna do oznaczania liczby drobnoustrojów: LACTOBACILLI MRS AGAR DRBC AGAR MANNITOL SALT AGAR PSEUDOMONAS CFC AGAR Selektywność\nMetoda jakościowa, płytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019 Pozywka stala agarowa selektywna do oznaczania liczby drobnoustrojow: LACTOBACILLI MRS AGAR DRBC AGAR MANNITOL SALT AGAR PSEUDOMONAS CFC AGAR Selektywnosc\nMetoda jakosciowa, plytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","categories":["microbiology"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Selective solid agar medium for the enumeration of microorganisms: LACTOBACILLI MRS AGAR DRBC AGAR MANNITOL SALT AGAR PSEUDOMONAS CFC AGAR Selectivity Qualitative plate method (streak plate) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","methodology_zh":"选择性","search_zh":"选择性 定性平板法（划线接种） PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","technique_zh":"定性平板法（划线接种）"},{"_id":"6a5dc9a8f1c10c8ce8259c57","lab_id":"69ad52a3de79e566650fb92b","country":"PL","accr_number":"AB 1740","accr_body":"PCA","test_object":"Pożywka stała agarowa selektywna do oznaczania liczby drobnoustrojów: CHROMOGENIC COLIFORM SLANTEZ BARTLEY","test_object_en":"Selective solid agar medium for enumeration of microorganisms: CHROMOGENIC COLIFORM SLANTEZ BARTLEY","methodology":"Żyzność","methodology_en":"Fertility","parameters":[],"parameters_en":[],"technique":"Metoda ilościowa, płytkowa (filtracja membranowa)","techniques":["Metoda ilościowa, płytkowa (filtracja membranowa)"],"technique_en":"Quantitative plate method (membrane filtration)","computed":[],"computed_en":[],"activity":"Żyzność\nMetoda ilościowa, płytkowa (filtracja membranowa)","reference":"PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","norm_bases":["PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pożywka stała agarowa selektywna do oznaczania liczby drobnoustrojów: CHROMOGENIC COLIFORM SLANTEZ BARTLEY Żyzność\nMetoda ilościowa, płytkowa (filtracja membranowa) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019 Pozywka stala agarowa selektywna do oznaczania liczby drobnoustrojow: CHROMOGENIC COLIFORM SLANTEZ BARTLEY Zyznosc\nMetoda ilosciowa, plytkowa (filtracja membranowa) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","categories":["microbiology"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Selective solid agar medium for enumeration of microorganisms: CHROMOGENIC COLIFORM SLANTEZ BARTLEY Fertility Quantitative plate method (membrane filtration) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","methodology_zh":"肥力","search_zh":"用于微生物计数的选择性固体琼脂培养基：CHROMOGENIC COLIFORM、SLANTEZ BARTLEY 肥力 定量平板法（膜过滤） PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","technique_zh":"定量平板法（膜过滤）","test_object_zh":"用于微生物计数的选择性固体琼脂培养基：CHROMOGENIC COLIFORM、SLANTEZ BARTLEY"},{"_id":"6a5dc9a8f1c10c8ce8259c58","lab_id":"69ad52a3de79e566650fb92b","country":"PL","accr_number":"AB 1740","accr_body":"PCA","test_object":"Pożywka stała agarowa selektywna do oznaczania liczby drobnoustrojów: CHROMOGENIC COLIFORM SLANTEZ BARTLEY","test_object_en":"Selective solid agar medium for enumeration of microorganisms: CHROMOGENIC COLIFORM SLANTEZ BARTLEY","methodology":"Selektywność","methodology_en":"Selectivity","parameters":[],"parameters_en":[],"technique":"Metoda jakościowa płytkowa (posiew rysowy)","techniques":["Metoda jakościowa płytkowa (posiew rysowy)"],"technique_en":"Qualitative plate method (streak plate)","computed":[],"computed_en":[],"activity":"Selektywność\nMetoda jakościowa płytkowa (posiew rysowy)","reference":"PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","norm_bases":["PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pożywka stała agarowa selektywna do oznaczania liczby drobnoustrojów: CHROMOGENIC COLIFORM SLANTEZ BARTLEY Selektywność\nMetoda jakościowa płytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019 Pozywka stala agarowa selektywna do oznaczania liczby drobnoustrojow: CHROMOGENIC COLIFORM SLANTEZ BARTLEY Selektywnosc\nMetoda jakosciowa plytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","categories":["microbiology"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Selective solid agar medium for enumeration of microorganisms: CHROMOGENIC COLIFORM SLANTEZ BARTLEY Selectivity Qualitative plate method (streak plate) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","methodology_zh":"选择性","search_zh":"用于微生物计数的选择性固体琼脂培养基：CHROMOGENIC COLIFORM、SLANTEZ BARTLEY 选择性 定性平板法（划线接种） PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","technique_zh":"定性平板法（划线接种）","test_object_zh":"用于微生物计数的选择性固体琼脂培养基：CHROMOGENIC COLIFORM、SLANTEZ BARTLEY"},{"_id":"6a5dc9a8f1c10c8ce8259c59","lab_id":"69ad52a3de79e566650fb92b","country":"PL","accr_number":"AB 1740","accr_body":"PCA","test_object":"Pożywka stała agarowa selektywna do oznaczania liczby drobnoustrojów: CHROMOGENIC COLIFORM SLANTEZ BARTLEY","test_object_en":"Selective solid agar medium for enumeration of microorganisms: CHROMOGENIC COLIFORM SLANTEZ BARTLEY","methodology":"Specyficzność","methodology_en":"Specificity","parameters":[],"parameters_en":[],"technique":"Metoda jakościowa, płytkowa (posiew rysowy)","techniques":["Metoda jakościowa, płytkowa (posiew rysowy)"],"technique_en":"Qualitative plate method (streak plate)","computed":[],"computed_en":[],"activity":"Specyficzność\nMetoda jakościowa, płytkowa (posiew rysowy)","reference":"PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","norm_bases":["PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pożywka stała agarowa selektywna do oznaczania liczby drobnoustrojów: CHROMOGENIC COLIFORM SLANTEZ BARTLEY Specyficzność\nMetoda jakościowa, płytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019 Pozywka stala agarowa selektywna do oznaczania liczby drobnoustrojow: CHROMOGENIC COLIFORM SLANTEZ BARTLEY Specyficznosc\nMetoda jakosciowa, plytkowa (posiew rysowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","categories":["microbiology"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Selective solid agar medium for enumeration of microorganisms: CHROMOGENIC COLIFORM SLANTEZ BARTLEY Specificity Qualitative plate method (streak plate) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","search_zh":"用于微生物计数的选择性固体琼脂培养基：CHROMOGENIC COLIFORM、SLANTEZ BARTLEY 特异性 定性平板法（划线接种） PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","technique_zh":"定性平板法（划线接种）","methodology_zh":"特异性","test_object_zh":"用于微生物计数的选择性固体琼脂培养基：CHROMOGENIC COLIFORM、SLANTEZ BARTLEY"},{"_id":"6a5dc9a8f1c10c8ce8259c5a","lab_id":"69ad52a3de79e566650fb92b","country":"PL","accr_number":"AB 1740","accr_body":"PCA","test_object":"Pożywka stała agarowa do oznaczania liczby drobnoustrojów: BLOOD AGAR PCA COLUMBIA AGAR Z KRWIĄ BARANIĄ TRYPTIC SOY AGAR","test_object_en":"Solid agar medium for the enumeration of microorganisms: BLOOD AGAR PCA COLUMBIA AGAR WITH SHEEP BLOOD TRYPTIC SOY AGAR","methodology":"Żyzność","methodology_en":"Fertility","parameters":[],"parameters_en":[],"technique":"Metoda ilościowa, płytkowa (posiew powierzchniowy)","techniques":["Metoda ilościowa, płytkowa (posiew powierzchniowy)"],"technique_en":"Quantitative plate method (spread plate)","computed":[],"computed_en":[],"activity":"Żyzność\nMetoda ilościowa, płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","norm_bases":["PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pożywka stała agarowa do oznaczania liczby drobnoustrojów: BLOOD AGAR PCA COLUMBIA AGAR Z KRWIĄ BARANIĄ TRYPTIC SOY AGAR Żyzność\nMetoda ilościowa, płytkowa (posiew powierzchniowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019 Pozywka stala agarowa do oznaczania liczby drobnoustrojow: BLOOD AGAR PCA COLUMBIA AGAR Z KRWIA BARANIA TRYPTIC SOY AGAR Zyznosc\nMetoda ilosciowa, plytkowa (posiew powierzchniowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","categories":["microbiology"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid agar medium for the enumeration of microorganisms: BLOOD AGAR PCA COLUMBIA AGAR WITH SHEEP BLOOD TRYPTIC SOY AGAR Fertility Quantitative plate method (spread plate) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","methodology_zh":"肥力","search_zh":"肥力 定量平板法（表面涂布） PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","technique_zh":"定量平板法（表面涂布）"},{"_id":"6a5dc9a8f1c10c8ce8259c5b","lab_id":"69ad52a3de79e566650fb92b","country":"PL","accr_number":"AB 1740","accr_body":"PCA","test_object":"Pożywka płynna selektywna: MKKTn BULION RVS BULION FRASER BULION HALF FRASER BULION","test_object_en":"Selective liquid medium: MKKTn BROTH RVS BROTH FRASER BROTH HALF FRASER BROTH","methodology":"Żyzność","methodology_en":"Fertility","parameters":[],"parameters_en":[],"technique":"Metoda jakościowa probówkowa, hodowlana","techniques":["Metoda jakościowa probówkowa, hodowlana"],"technique_en":"Qualitative tube culture method","computed":[],"computed_en":[],"activity":"Żyzność\nMetoda jakościowa probówkowa, hodowlana","reference":"PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","norm_bases":["PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pożywka płynna selektywna: MKKTn BULION RVS BULION FRASER BULION HALF FRASER BULION Żyzność\nMetoda jakościowa probówkowa, hodowlana PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019 Pozywka plynna selektywna: MKKTn BULION RVS BULION FRASER BULION HALF FRASER BULION Zyznosc\nMetoda jakosciowa probowkowa, hodowlana PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Selective liquid medium: MKKTn BROTH RVS BROTH FRASER BROTH HALF FRASER BROTH Fertility Qualitative tube culture method PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","methodology_zh":"肥力","search_zh":"肥力 PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"},{"_id":"6a5dc9a8f1c10c8ce8259c5c","lab_id":"69ad52a3de79e566650fb92b","country":"PL","accr_number":"AB 1740","accr_body":"PCA","test_object":"Pożywka płynna selektywna: MKKTn BULION RVS BULION FRASER BULION HALF FRASER BULION","test_object_en":"Selective liquid medium: MKKTn BROTH RVS BROTH FRASER BROTH HALF FRASER BROTH","methodology":"Selektywność","methodology_en":"Selectivity","parameters":[],"parameters_en":[],"technique":"Metoda jakościowa probówkowa, hodowlana","techniques":["Metoda jakościowa probówkowa, hodowlana"],"technique_en":"Qualitative tube culture method","computed":[],"computed_en":[],"activity":"Selektywność\nMetoda jakościowa probówkowa, hodowlana","reference":"PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","norm_bases":["PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pożywka płynna selektywna: MKKTn BULION RVS BULION FRASER BULION HALF FRASER BULION Selektywność\nMetoda jakościowa probówkowa, hodowlana PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019 Pozywka plynna selektywna: MKKTn BULION RVS BULION FRASER BULION HALF FRASER BULION Selektywnosc\nMetoda jakosciowa probowkowa, hodowlana PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Selective liquid medium: MKKTn BROTH RVS BROTH FRASER BROTH HALF FRASER BROTH Selectivity Qualitative tube culture method PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","methodology_zh":"选择性","search_zh":"选择性 PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"},{"_id":"6a5dc9a8f1c10c8ce8259c5d","lab_id":"69ad52a3de79e566650fb92b","country":"PL","accr_number":"AB 1740","accr_body":"PCA","test_object":"Pożywka płynna selektywna: LAURYL SULPHATE BULION","test_object_en":"Selective liquid medium: LAURYL SULPHATE BROTH","methodology":"Żyzność","methodology_en":"Fertility","parameters":[],"parameters_en":[],"technique":"Metoda jakościowa pojedynczej probówki (zmętnienie)","techniques":["Metoda jakościowa pojedynczej probówki (zmętnienie)"],"technique_en":"Qualitative single tube method (turbidity)","computed":[],"computed_en":[],"activity":"Żyzność\nMetoda jakościowa pojedynczej probówki (zmętnienie)","reference":"PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","norm_bases":["PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pożywka płynna selektywna: LAURYL SULPHATE BULION Żyzność\nMetoda jakościowa pojedynczej probówki (zmętnienie) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019 Pozywka plynna selektywna: LAURYL SULPHATE BULION Zyznosc\nMetoda jakosciowa pojedynczej probowki (zmetnienie) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","categories":["other"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Selective liquid medium: LAURYL SULPHATE BROTH Fertility Qualitative single tube method (turbidity) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","methodology_zh":"肥力","search_zh":"肥力 单管定性法（浑浊度） PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","technique_zh":"单管定性法（浑浊度）"},{"_id":"6a5dc9a8f1c10c8ce8259c5e","lab_id":"69ad52a3de79e566650fb92b","country":"PL","accr_number":"AB 1740","accr_body":"PCA","test_object":"Pożywka płynna selektywna: LAURYL SULPHATE BULION","test_object_en":"Selective liquid medium: LAURYL SULPHATE BROTH","methodology":"Selektywność","methodology_en":"Selectivity","parameters":[],"parameters_en":[],"technique":"Metoda jakościowa pojedynczej probówki (zmętnienie)","techniques":["Metoda jakościowa pojedynczej probówki (zmętnienie)"],"technique_en":"Qualitative single tube method (turbidity)","computed":[],"computed_en":[],"activity":"Selektywność\nMetoda jakościowa pojedynczej probówki (zmętnienie)","reference":"PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","norm_bases":["PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pożywka płynna selektywna: LAURYL SULPHATE BULION Selektywność\nMetoda jakościowa pojedynczej probówki (zmętnienie) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019 Pozywka plynna selektywna: LAURYL SULPHATE BULION Selektywnosc\nMetoda jakosciowa pojedynczej probowki (zmetnienie) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Selective liquid medium: LAURYL SULPHATE BROTH Selectivity Qualitative single tube method (turbidity) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","methodology_zh":"选择性","search_zh":"选择性 单管定性法（浑浊度） PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","technique_zh":"单管定性法（浑浊度）"},{"_id":"6a5dc9a8f1c10c8ce8259c5f","lab_id":"69ad52a3de79e566650fb92b","country":"PL","accr_number":"AB 1740","accr_body":"PCA","test_object":"Pożywka płynna: BHI BULION BUFOROWANA WODA PEPTONOWA TSB BULION THIOGLICOLLATE BULION","test_object_en":"Liquid medium: BHI BROTH BUFFERED PEPTONE WATER TSB BROTH THIOGLYCOLLATE BROTH","methodology":"Żyzność","methodology_en":"Fertility","parameters":[],"parameters_en":[],"technique":"Metoda jakościowa pojedynczej probówki (zmętnienie)","techniques":["Metoda jakościowa pojedynczej probówki (zmętnienie)"],"technique_en":"Qualitative single tube method (turbidity)","computed":[],"computed_en":[],"activity":"Żyzność\nMetoda jakościowa pojedynczej probówki (zmętnienie)","reference":"PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","norm_bases":["PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pożywka płynna: BHI BULION BUFOROWANA WODA PEPTONOWA TSB BULION THIOGLICOLLATE BULION Żyzność\nMetoda jakościowa pojedynczej probówki (zmętnienie) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019 Pozywka plynna: BHI BULION BUFOROWANA WODA PEPTONOWA TSB BULION THIOGLICOLLATE BULION Zyznosc\nMetoda jakosciowa pojedynczej probowki (zmetnienie) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Liquid medium: BHI BROTH BUFFERED PEPTONE WATER TSB BROTH THIOGLYCOLLATE BROTH Fertility Qualitative single tube method (turbidity) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","methodology_zh":"肥力","search_zh":"肥力 单管定性法（浑浊度） PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","technique_zh":"单管定性法（浑浊度）"},{"_id":"6a5dc9a8f1c10c8ce8259c60","lab_id":"69ad52a3de79e566650fb92b","country":"PL","accr_number":"AB 1740","accr_body":"PCA","test_object":"Pożywka płynna: Płyn do rozcieńczeń: ROZTWÓR 0,85% NaCl ROZTWÓR 0,9% NaCl BUFOROWANY ROZTWÓR 0,85%, NaCl","test_object_en":"Liquid medium: Diluent: 0,85% NaCl SOLUTION 0,9% NaCl SOLUTION BUFFERED 0,85% SOLUTION, NaCl","methodology":"Żyzność","methodology_en":"Fertility","parameters":[],"parameters_en":[],"technique":"Metoda ilościowa (posiew powierzchniowy)","techniques":["Metoda ilościowa (posiew powierzchniowy)"],"technique_en":"Quantitative method (surface plating)","computed":[],"computed_en":[],"activity":"Żyzność\nMetoda ilościowa (posiew powierzchniowy)","reference":"PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","norm_bases":["PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pożywka płynna: Płyn do rozcieńczeń: ROZTWÓR 0,85% NaCl ROZTWÓR 0,9% NaCl BUFOROWANY ROZTWÓR 0,85%, NaCl Żyzność\nMetoda ilościowa (posiew powierzchniowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019 Pozywka plynna: Plyn do rozcienczen: ROZTWOR 0,85% NaCl ROZTWOR 0,9% NaCl BUFOROWANY ROZTWOR 0,85%, NaCl Zyznosc\nMetoda ilosciowa (posiew powierzchniowy) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","categories":["other"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Liquid medium: Diluent: 0,85% NaCl SOLUTION 0,9% NaCl SOLUTION BUFFERED 0,85% SOLUTION, NaCl Fertility Quantitative method (surface plating) PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019","methodology_zh":"肥力","search_zh":"肥力 PN-EN ISO 11133:2014-07 + A1:2018-04 + A2:2020-10 I-08_wydanie 2 z dnia 18.12.2019"}],"has_pdf":true}