{"lab":{"_id":"69ad52a3de79e566650fb927","accr_number":"AB 1737","country":"PL","accr_body":"PCA","address":"ul. Kochanowskiego 29, 64-800 Chodzież, LABORATORIUM, Studzieniec - Łęg","categories":["water","microbiology"],"city":"Chodzież","imported_at":"2026-03-08T10:42:43.265Z","methods_count":36,"name":"MIEJSKIE WODOCIĄGI I KANALIZACJA Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1737.pdf"],"scope_summary":"","search_text":"miejskie wodociągi i kanalizacja sp. z o.o. ul. kochanowskiego 29, 64-800 chodzież, laboratorium, studzieniec - łęg other water pharma electronics microbiology automotive","status":"active","updated_at":"2026-03-08T14:50:51.549Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:51.549Z","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%201737,podmiot.html","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests of water, drinking water"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties of water, drinking water, sewage"}],"issue":{"no":"7","date":"15.01.2026"},"parse_date":"2026-07-20T07:09:28.401Z","parse_source":"script-pdfplumber","map_coord":[52.980906,16.911516],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":36,"microbiology":5},"category_scores":{"water":31.61,"microbiology":0.61},"has_zh":true},"methods":[{"_id":"6a5dc9a8f1c10c8ce8259c10","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura pobranej próbki ścieków"},{"name":"Zakres","range":"(2,0 - 45,0) 0C"}],"parameters_en":[{"name":"Temperature of the collected wastewater sample"},{"name":"Range","range":"(2,0 - 45,0) 0C"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"technique_en":"Manual method; Automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (2,0 - 45,0) 0C\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (2,0 - 45,0) 0C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow\nZakres (2,0 - 45,0) 0C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Temperature of the collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采废水样品的温度"},{"name":"范围","range":"(2,0 - 45,0) 0C"}],"search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a5dc9a8f1c10c8ce8259c11","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(2,00 - 500) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,00 - 500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (2,00 - 500) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (2,00 - 500) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla\nZakres (2,00 - 500) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(2,00 - 500) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9a8f1c10c8ce8259c12","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego","methodology_en":"Total nitrogen concentration","parameters":[],"parameters_en":[],"technique":"Metoda (z obliczeń)","techniques":["Metoda (z obliczeń)"],"technique_en":"Method (calculated)","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego\nMetoda (z obliczeń)","reference":"PB-1 wyd. 1 z dnia 2.09.2019 r.","norm_bases":["PB-1 wyd. 1 z dnia 2.09.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego\nMetoda (z obliczeń) PB-1 wyd. 1 z dnia 2.09.2019 r. Scieki Stezenie azotu ogolnego\nMetoda (z obliczen) PB-1 wyd. 1 z dnia 2.09.2019 r.","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total nitrogen concentration Method (calculated) PB-1 wyd. 1 z dnia 2.09.2019 r.","methodology_zh":"总氮浓度","search_zh":"污水 总氮浓度 PB-1 wyd. 1 z dnia 2.09.2019 r.","test_object_zh":"污水"},{"_id":"6a5dc9a8f1c10c8ce8259c13","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,20 - 30,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,20 - 30,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,20 - 30,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 + Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 + Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,20 - 30,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 + Ap1:2010+Ap2:2010 Scieki Stezenie fosforu ogolnego\nZakres (0,20 - 30,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 + Ap1:2010+Ap2:2010","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 + Ap1:2010+Ap2:2010","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,20 - 30,0) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 + Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9a8f1c10c8ce8259c14","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1,0 - 6,0) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1,0 - 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 - 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 - 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Scieki, Woda Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 - 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN 1899-2:2002","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1,0 - 6,0) mg/l O2"}],"search_zh":"废水、水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"废水、水"},{"_id":"6a5dc9a8f1c10c8ce8259c15","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3,0 - 3500) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3,0 - 3500) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3,0 - 3500) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3,0 - 3500) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki, Woda Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3,0 - 3500) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN ISO 5815-1:2019-12","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3,0 - 3500) mg/l O2"}],"search_zh":"废水、水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"废水、水"},{"_id":"6a5dc9a8f1c10c8ce8259c16","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Chemiczne zapotrzebowania tlenu","methodology_en":"Chemical oxygen demand","parameters":[{"name":"ChZT - Cr"},{"name":"Zakres","range":"(3,0 - 10000) mg/l O2"}],"parameters_en":[{"name":"COD - Cr"},{"name":"Range","range":"(3,0 - 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowania tlenu\nZakres:\nChZT - Cr\nZakres (3,0 - 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Chemiczne zapotrzebowania tlenu\nZakres:\nChZT - Cr\nZakres (3,0 - 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki, Woda Chemiczne zapotrzebowania tlenu\nZakres:\nChZT - Cr\nZakres (3,0 - 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Chemical oxygen demand Spectrophotometric method COD - Cr Range PN-ISO 15705:2005","parameters_zh":[{"name":"COD-Cr"},{"name":"范围","range":"(3,0 - 10000) mg/l O2"}],"search_zh":"废水、水 分光光度法 COD-Cr 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a5dc9a8f1c10c8ce8259c17","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(3,0 - 3500) mg/l"}],"parameters_en":[{"name":"Range","range":"(3,0 - 3500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (3,0 - 3500) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Zawiesiny ogólne\nZakres (3,0 - 3500) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki, Woda Zawiesiny ogolne\nZakres (3,0 - 3500) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(3,0 - 3500) mg/l"}],"search_zh":"废水、水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"废水、水"},{"_id":"6a5dc9a8f1c10c8ce8259c18","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Oznaczanie azotu amonowego w wodzie metodą bezpośredniej nessleryzacji","methodology_en":"Determination of ammonium nitrogen in water by the direct Nesslerization method","parameters":[{"name":"Zakres","range":"(0,4 - 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,4 - 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Oznaczanie azotu amonowego w wodzie metodą bezpośredniej nessleryzacji\nZakres (0,4 - 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-4:1994","norm_bases":["PN-C-04576-4:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Oznaczanie azotu amonowego w wodzie metodą bezpośredniej nessleryzacji\nZakres (0,4 - 100) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994 Scieki, Woda Oznaczanie azotu amonowego w wodzie metoda bezposredniej nessleryzacji\nZakres (0,4 - 100) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Determination of ammonium nitrogen in water by the direct Nesslerization method Spectrophotometric method Range PN-C-04576-4:1994","parameters_zh":[{"name":"范围","range":"(0,4 - 100) mg/l"}],"search_zh":"废水、水 分光光度法 范围 PN-C-04576-4:1994","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a5dc9a8f1c10c8ce8259c19","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters":[{"name":"Zakres","range":"(2,0 - 45,0) 0C"}],"parameters_en":[{"name":"Range","range":"(2,0 - 45,0) 0C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (2,0 - 45,0) 0C","reference":"PN-ISO 5667-5:2017-10 | PN-77/C-04584","norm_bases":["PN-ISO 5667-5:2017-10","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (2,0 - 45,0) 0C PN-ISO 5667-5:2017-10 | PN-77/C-04584 Woda, Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (2,0 - 45,0) 0C PN-ISO 5667-5:2017-10 | PN-77/C-04584","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Sampling for chemical and physical testing Temperature of the water sample taken Range PN-ISO 5667-5:2017-10 | PN-77/C-04584","parameters_zh":[{"name":"范围","range":"(2,0 - 45,0) 0C"}],"search_zh":"水、生活饮用水 化学和物理检测采样 所采水样的温度 范围 PN-ISO 5667-5:2017-10 | PN-77/C-04584","test_object_zh":"水、生活饮用水","methodology_zh":"化学和物理检测采样 所采水样的温度"},{"_id":"6a5dc9a8f1c10c8ce8259c1a","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(15 - 4000) μg/l"}],"parameters_en":[{"name":"Range","range":"(15 - 4000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (15 - 4000) μg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590/03","norm_bases":["PN-92/C-04590/03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (15 - 4000) μg/l\nMetoda spektrofotometryczna PN-92/C-04590/03 Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (15 - 4000) μg/l\nMetoda spektrofotometryczna PN-92/C-04590/03","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Manganese concentration Spectrophotometric method Range PN-92/C-04590/03","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(15 - 4000) μg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 范围 PN-92/C-04590/03","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9a8f1c10c8ce8259c1b","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"Stężenie jonu amonowego","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,02 - 5,0) mg/l N-NH4"},{"name":"Zakres","range":"(0,025 - 6,4) mg/l NH4+"}],"parameters_en":[{"name":"Range","range":"(0,02 - 5,0) mg/l N-NH4"},{"name":"Range","range":"(0,025 - 6,4) mg/l NH4+"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego\nZakres:\nZakres (0,02 - 5,0) mg/l N-NH4\nZakres (0,025 - 6,4) mg/l NH4+\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie jonu amonowego\nZakres:\nZakres (0,02 - 5,0) mg/l N-NH4\nZakres (0,025 - 6,4) mg/l NH4+\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Woda do spozycia przez ludzi, Scieki Stezenie jonu amonowego\nZakres:\nZakres (0,02 - 5,0) mg/l N-NH4\nZakres (0,025 - 6,4) mg/l NH4+\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Ammonium ion concentration Spectrophotometric method Range Range PN-ISO 7150-1:2002","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,02 - 5,0) mg/l N-NH4"},{"name":"范围","range":"(0,025 - 6,4) mg/l NH4+"}],"search_zh":"水、生活饮用水、废水 铵离子浓度 分光光度法 范围 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5dc9a8f1c10c8ce8259c1c","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,004 - 4,0) mg/l N-NO2"},{"name":"Zakres","range":"(0,0125 - 13,5) mg/l NO2-"}],"parameters_en":[{"name":"Range","range":"(0,004 - 4,0) mg/l N-NO2"},{"name":"Range","range":"(0,0125 - 13,5) mg/l NO2-"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres:\nZakres (0,004 - 4,0) mg/l N-NO2\nZakres (0,0125 - 13,5) mg/l NO2-\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotu azotynowego\nZakres:\nZakres (0,004 - 4,0) mg/l N-NO2\nZakres (0,0125 - 13,5) mg/l NO2-\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotu azotynowego\nZakres:\nZakres (0,004 - 4,0) mg/l N-NO2\nZakres (0,0125 - 13,5) mg/l NO2-\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Nitrite nitrogen concentration Spectrophotometric method Range Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,004 - 4,0) mg/l N-NO2"},{"name":"范围","range":"(0,0125 - 13,5) mg/l NO2-"}],"search_zh":"水、生活饮用水、废水 亚硝态氮浓度 分光光度法 范围 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5dc9a8f1c10c8ce8259c1d","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(100- 2500) μS/cm"}],"parameters_en":[{"name":"Range","range":"(100- 2500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (100- 2500) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Przewodność elektryczna właściwa\nZakres (100- 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi, Scieki Przewodnosc elektryczna wlasciwa\nZakres (100- 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100- 2500) μS/cm"}],"search_zh":"水、生活饮用水、废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5dc9a8f1c10c8ce8259c1e","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"Stężenie żelaza","methodology_en":"Iron concentration","parameters":[{"name":"Zakres","range":"(20 - 10000) μg/l"}],"parameters_en":[{"name":"Range","range":"(20 - 10000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza\nZakres (20 - 10000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie żelaza\nZakres (20 - 10000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, Woda do spozycia przez ludzi, Scieki Stezenie zelaza\nZakres (20 - 10000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(20 - 10000) μg/l"}],"search_zh":"水、生活饮用水、废水 铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5dc9a8f1c10c8ce8259c1f","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(10,0 - 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(10,0 - 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (10,0 - 1000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie siarczanów\nZakres (10,0 - 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, Woda do spozycia przez ludzi, Scieki Stezenie siarczanow\nZakres (10,0 - 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10,0 - 1000) mg/l"}],"search_zh":"水、生活饮用水、废水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5dc9a8f1c10c8ce8259c20","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 - 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 - 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi, Scieki pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 - 10,0"}],"search_zh":"水、生活饮用水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5dc9a8f1c10c8ce8259c21","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,0 - 400) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 - 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,0 - 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie chlorków\nZakres (5,0 - 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Woda do spozycia przez ludzi, Scieki Stezenie chlorkow\nZakres (5,0 - 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 - 400) mg/l"}],"search_zh":"水、生活饮用水、废水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5dc9a8f1c10c8ce8259c22","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Pobieranie próbek wody do badań chemicznych i fizycznych Temperatura pobranej próbki wody","methodology_en":"Water sampling for chemical and physical testing Temperature of the collected water sample","parameters":[{"name":"Zakres","range":"(2,0 - 45,0) 0C"}],"parameters_en":[{"name":"Range","range":"(2,0 - 45,0) 0C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek wody do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (2,0 - 45,0) 0C","reference":"PB-4 wyd.1 z dnia 11.10.2021 r. | PN-77/C-04584","norm_bases":["PB-4 wyd.1 z dnia 11.10.2021 r.","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Pobieranie próbek wody do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (2,0 - 45,0) 0C PB-4 wyd.1 z dnia 11.10.2021 r. | PN-77/C-04584 Woda na plywalniach Pobieranie probek wody do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (2,0 - 45,0) 0C PB-4 wyd.1 z dnia 11.10.2021 r. | PN-77/C-04584","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Water sampling for chemical and physical testing Temperature of the collected water sample Range PB-4 wyd.1 z dnia 11.10.2021 r. | PN-77/C-04584","parameters_zh":[{"name":"范围","range":"(2,0 - 45,0) 0C"}],"search_zh":"游泳池水 范围 PB-4 wyd.1 z dnia 11.10.2021 r. | PN-77/C-04584","test_object_zh":"游泳池水"},{"_id":"6a5dc9a8f1c10c8ce8259c23","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach","test_object_en":"Water, Water intended for human consumption, Swimming pool water","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,12 - 10) NTU"}],"parameters_en":[{"name":"Range","range":"(0,12 - 10) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,12 - 10) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach Mętność\nZakres (0,12 - 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi, Woda na plywalniach Metnosc\nZakres (0,12 - 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Swimming pool water Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,12 - 10) NTU"}],"search_zh":"水、生活饮用水、游泳池水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水、游泳池水"},{"_id":"6a5dc9a8f1c10c8ce8259c24","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach","test_object_en":"Water, Water intended for human consumption, Swimming pool water","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(3,5 - 100) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(3,5 - 100) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (3,5 - 100) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 metoda C+Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 metoda C+Ap1:2015-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach Barwa\nZakres (3,5 - 100) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C+Ap1:2015-06 Woda, Woda do spozycia przez ludzi, Woda na plywalniach Barwa\nZakres (3,5 - 100) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C+Ap1:2015-06","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Swimming pool water Colour Spectrophotometric method Range PN-EN ISO 7887:2012 metoda C+Ap1:2015-06","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(3,5 - 100) mg/l Pt"}],"search_zh":"水、生活饮用水、游泳池水 色度 分光光度法 范围 PN-EN ISO 7887:2012 metoda C+Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、游泳池水"},{"_id":"6a5dc9a8f1c10c8ce8259c25","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach","test_object_en":"Water, Water intended for human consumption, Swimming pool water","methodology":"Oznaczanie indeksu nadmanganianowego","methodology_en":"Determination of permanganate index","parameters":[{"name":"Zakres","range":"(0,5 - 10) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,5 - 10) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Oznaczanie indeksu nadmanganianowego\nZakres (0,5 - 10) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach Oznaczanie indeksu nadmanganianowego\nZakres (0,5 - 10) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, Woda do spozycia przez ludzi, Woda na plywalniach Oznaczanie indeksu nadmanganianowego\nZakres (0,5 - 10) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Swimming pool water Determination of permanganate index Titrimetric method Range PN-EN ISO 8467:2001","parameters_zh":[{"name":"范围","range":"(0,5 - 10) mg/l"}],"search_zh":"水、生活饮用水、游泳池水 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、游泳池水"},{"_id":"6a5dc9a8f1c10c8ce8259c26","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach, Ścieki","test_object_en":"Water, Water intended for human consumption, Swimming pool water, Wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,02 - 11,3) mg/l N-NO3"},{"name":"Zakres","range":"(0,10 - 50) mg/l NO3-"}],"parameters_en":[{"name":"Range","range":"(0,02 - 11,3) mg/l N-NO3"},{"name":"Range","range":"(0,10 - 50) mg/l NO3-"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres:\nZakres (0,02 - 11,3) mg/l N-NO3\nZakres (0,10 - 50) mg/l NO3-\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach, Ścieki Stężenie azotu azotanowego\nZakres:\nZakres (0,02 - 11,3) mg/l N-NO3\nZakres (0,10 - 50) mg/l NO3-\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, Woda do spozycia przez ludzi, Woda na plywalniach, Scieki Stezenie azotu azotanowego\nZakres:\nZakres (0,02 - 11,3) mg/l N-NO3\nZakres (0,10 - 50) mg/l NO3-\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Swimming pool water, Wastewater Nitrate nitrogen concentration Spectrophotometric method Range Range PN-82/C-04576/08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,02 - 11,3) mg/l N-NO3"},{"name":"范围","range":"(0,10 - 50) mg/l NO3-"}],"search_zh":"硝态氮浓度 分光光度法 范围 范围 PN-82/C-04576/08","technique_zh":"分光光度法"},{"_id":"6a5dc9a8f1c10c8ce8259c27","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda na pływalniach","test_object_en":"Water, Swimming pool water","methodology":"Stężenie chloru wolnego","methodology_en":"Free chlorine concentration","parameters":[{"name":"Zakres","range":"(0,09 - 2) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,09 - 2) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"technique_en":"Colorimetric method","computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego\nZakres (0,09 - 2) mg/l\nMetoda kolorymetryczna","reference":"PB-2 wyd. 2 z dnia 11.10.2021 | na podstawie testu SwifTestDPD nr 2105560","norm_bases":["PB-2 wyd. 2 z dnia 11.10.2021","na podstawie testu SwifTestDPD nr 2105560"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda na pływalniach Stężenie chloru wolnego\nZakres (0,09 - 2) mg/l\nMetoda kolorymetryczna PB-2 wyd. 2 z dnia 11.10.2021 | na podstawie testu SwifTestDPD nr 2105560 Woda, Woda na plywalniach Stezenie chloru wolnego\nZakres (0,09 - 2) mg/l\nMetoda kolorymetryczna PB-2 wyd. 2 z dnia 11.10.2021 | na podstawie testu SwifTestDPD nr 2105560","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Swimming pool water Free chlorine concentration Colorimetric method Range PB-2 wyd. 2 z dnia 11.10.2021 | na podstawie testu SwifTestDPD nr 2105560","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,09 - 2) mg/l"}],"search_zh":"水、游泳池水 游离氯浓度 比色法 范围 PB-2 wyd. 2 z dnia 11.10.2021 | na podstawie testu SwifTestDPD nr 2105560","technique_zh":"比色法","test_object_zh":"水、游泳池水"},{"_id":"6a5dc9a8f1c10c8ce8259c28","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda na pływalniach","test_object_en":"Water, Swimming pool water","methodology":"Stężenie chloru całkowitego","methodology_en":"Total chlorine concentration","parameters":[{"name":"Zakres","range":"(0,09 - 2) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,09 - 2) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"technique_en":"Colorimetric method","computed":[],"computed_en":[],"activity":"Stężenie chloru całkowitego\nZakres (0,09 - 2) mg/l\nMetoda kolorymetryczna","reference":"PB-2 wyd. 2 z dnia 11.10.2021 | na podstawie testu SwifTestDPD nr 2105660","norm_bases":["PB-2 wyd. 2 z dnia 11.10.2021","na podstawie testu SwifTestDPD nr 2105660"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda na pływalniach Stężenie chloru całkowitego\nZakres (0,09 - 2) mg/l\nMetoda kolorymetryczna PB-2 wyd. 2 z dnia 11.10.2021 | na podstawie testu SwifTestDPD nr 2105660 Woda, Woda na plywalniach Stezenie chloru calkowitego\nZakres (0,09 - 2) mg/l\nMetoda kolorymetryczna PB-2 wyd. 2 z dnia 11.10.2021 | na podstawie testu SwifTestDPD nr 2105660","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Swimming pool water Total chlorine concentration Colorimetric method Range PB-2 wyd. 2 z dnia 11.10.2021 | na podstawie testu SwifTestDPD nr 2105660","parameters_zh":[{"name":"范围","range":"(0,09 - 2) mg/l"}],"search_zh":"水、游泳池水 总氯浓度 比色法 范围 PB-2 wyd. 2 z dnia 11.10.2021 | na podstawie testu SwifTestDPD nr 2105660","technique_zh":"比色法","methodology_zh":"总氯浓度","test_object_zh":"水、游泳池水"},{"_id":"6a5dc9a8f1c10c8ce8259c29","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda na pływalniach","test_object_en":"Water, Swimming pool water","methodology":"Chlor związany (z obliczeń)","methodology_en":"Combined chlorine (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Chlor związany (z obliczeń)","reference":"PB-2 wyd. 2 z dnia 11.10.2021","norm_bases":["PB-2 wyd. 2 z dnia 11.10.2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda na pływalniach Chlor związany (z obliczeń) PB-2 wyd. 2 z dnia 11.10.2021 Woda, Woda na plywalniach Chlor zwiazany (z obliczen) PB-2 wyd. 2 z dnia 11.10.2021","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Swimming pool water Combined chlorine (calculated) PB-2 wyd. 2 z dnia 11.10.2021","methodology_zh":"化合氯（由计算得出）","search_zh":"水、游泳池水 化合氯（由计算得出） PB-2 wyd. 2 z dnia 11.10.2021","test_object_zh":"水、游泳池水"},{"_id":"6a5dc9a8f1c10c8ce8259c2a","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda na pływalniach","test_object_en":"Water, Swimming pool water","methodology":"Potencjał utleniająco-redukujący (redox) wzgl. Ag/AgCl 3,5 mol/l KCl","methodology_en":"Oxidation-reduction potential (redox) vs. Ag/AgCl 3,5 mol/l KCl","parameters":[{"name":"Zakres","range":"(200 - 800) mV"}],"parameters_en":[{"name":"Range","range":"(200 - 800) mV"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"Potencjał utleniająco-redukujący (redox) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (200 - 800) mV\nMetoda potencjometryczna","reference":"PB-3 wyd. 2 z dnia 11.10.2021 r.","norm_bases":["PB-3 wyd. 2 z dnia 11.10.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda na pływalniach Potencjał utleniająco-redukujący (redox) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (200 - 800) mV\nMetoda potencjometryczna PB-3 wyd. 2 z dnia 11.10.2021 r. Woda, Woda na plywalniach Potencjal utleniajaco-redukujacy (redox) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (200 - 800) mV\nMetoda potencjometryczna PB-3 wyd. 2 z dnia 11.10.2021 r.","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Swimming pool water Oxidation-reduction potential (redox) vs. Ag/AgCl 3,5 mol/l KCl Potentiometric method Range PB-3 wyd. 2 z dnia 11.10.2021 r.","parameters_zh":[{"name":"范围","range":"(200 - 800) mV"}],"search_zh":"水、游泳池水 氧化还原电位（redox），相对于 Ag/AgCl 3,5 mol/l KCl 电位法 范围 PB-3 wyd. 2 z dnia 11.10.2021 r.","technique_zh":"电位法","test_object_zh":"水、游泳池水","methodology_zh":"氧化还原电位（redox），相对于 Ag/AgCl 3,5 mol/l KCl"},{"_id":"6a5dc9a8f1c10c8ce8259c2b","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach, Woda z kąpielisk i miejsc wykorzystywanych do kąpieli","test_object_en":"Water, Water intended for human consumption, Swimming pool water, Bathing water and water from sites used for bathing","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach, Woda z kąpielisk i miejsc wykorzystywanych do kąpieli Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda, Woda do spozycia przez ludzi, Woda na plywalniach, Woda z kapielisk i miejsc wykorzystywanych do kapieli Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Swimming pool water, Bathing water and water from sites used for bathing Sampling for microbiological testing PN-EN ISO 19458:2007","methodology_zh":"微生物检测用样品采集","search_zh":"微生物检测用样品采集 PN-EN ISO 19458:2007"},{"_id":"6a5dc9a8f1c10c8ce8259c2c","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach","test_object_en":"Water, Water intended for human consumption, Swimming pool water","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/ A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04 Woda, Woda do spozycia przez ludzi, Woda na plywalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","categories":["water","microbiology"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水、游泳池水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水、游泳池水"},{"_id":"6a5dc9a8f1c10c8ce8259c2d","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach","test_object_en":"Water, Water intended for human consumption, Swimming pool water","methodology":"Ogólna liczba mikroorganizmów w temp. 36 °C","methodology_en":"Total microorganism count at 36 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach Ogólna liczba mikroorganizmów w temp. 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi, Woda na plywalniach Ogolna liczba mikroorganizmow w temp. 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Swimming pool water Total microorganism count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"水、生活饮用水、游泳池水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水、游泳池水","methodology_zh":"36 °C 微生物总数"},{"_id":"6a5dc9a8f1c10c8ce8259c2e","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach","test_object_en":"Water, Water intended for human consumption, Swimming pool water","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda, Woda do spozycia przez ludzi, Woda na plywalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"水、生活饮用水、游泳池水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水、游泳池水"},{"_id":"6a5dc9a8f1c10c8ce8259c2f","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach","test_object_en":"Water, Water intended for human consumption, Swimming pool water","methodology":"Liczba bakterii z rodzaju Legionella","methodology_en":"Count of bacteria of the genus Legionella","parameters":[{"name":"Matryca A Procedura 5 (pożywka A), 7 (pożywka C – GVPC)"}],"parameters_en":[{"name":"Matrix A Procedure 5 (medium A), 7 (medium C – GVPC)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 5 (pożywka A), 7 (pożywka C – GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/ Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08","PN-EN ISO 11731:2017-08/ Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 5 (pożywka A), 7 (pożywka C – GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/ Ap1:2019-12 Woda, Woda do spozycia przez ludzi, Woda na plywalniach Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 5 (pozywka A), 7 (pozywka C – GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/ Ap1:2019-12","categories":["microbiology","water"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Swimming pool water Count of bacteria of the genus Legionella Membrane filtration method Matrix A Procedure 5 (medium A), 7 (medium C – GVPC) PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/ Ap1:2019-12","search_zh":"水、生活饮用水、游泳池水 军团菌属细菌计数 膜过滤法 PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/ Ap1:2019-12","technique_zh":"膜过滤法","methodology_zh":"军团菌属细菌计数","test_object_zh":"水、生活饮用水、游泳池水"},{"_id":"6a5dc9a8f1c10c8ce8259c30","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/ A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","categories":["water","microbiology"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9a8f1c10c8ce8259c31","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba enterokoków kałowych","methodology_en":"Intestinal enterococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","methodology_zh":"粪肠球菌计数","search_zh":"水、生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9a8f1c10c8ce8259c32","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w temp. 22 °C","methodology_en":"Total viable count at 22 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"水、生活饮用水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","methodology_zh":"22 °C 微生物总数"},{"_id":"6a5dc9a8f1c10c8ce8259c33","lab_id":"69ad52a3de79e566650fb927","country":"PL","accr_number":"AB 1737","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","methodology_en":"Most probable number, Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda zminiaturyzowana NPL","techniques":["Metoda zminiaturyzowana NPL"],"technique_en":"Miniaturized MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda zminiaturyzowana NPL","reference":"PN-EN ISO 9308-3:2002","norm_bases":["PN-EN ISO 9308-3:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda zminiaturyzowana NPL PN-EN ISO 9308-3:2002 Woda Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda zminiaturyzowana NPL PN-EN ISO 9308-3:2002","categories":["water","microbiology"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Most probable number, Escherichia coli Miniaturized MPN method PN-EN ISO 9308-3:2002","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"水 大肠埃希氏菌（Escherichia coli）最可能数（MPN） 微量 MPN 法 PN-EN ISO 9308-3:2002","test_object_zh":"水","technique_zh":"微量 MPN 法"}],"has_pdf":true}