{"lab":{"_id":"69ad52a3de79e566650fb913","accr_number":"AB 1721","country":"PL","accr_body":"PCA","address":"ul. Ozimska 53 lok. 4, 45-061 Opole, PROLAB Sp. z o.o. - Laboratorium, ul. Niemodlińska 23 lok. 40, 45-710 Opole","categories":["environment","construction"],"city":"Opole","imported_at":"2026-03-08T10:42:43.265Z","methods_count":20,"name":"PROLAB Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1721.pdf"],"scope_summary":"","search_text":"prolab sp. z o.o. ul. ozimska 53 lok. 4, 45-061 opole, prolab sp. z o.o. - laboratorium, ul. niemodlińska 23 lok. 40, 45-710 opole environment materials other construction electronics metrology","status":"active","updated_at":"2026-03-08T14:50:50.996Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:03:10.500Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201721,podmiot.html","fields_of_testing":[{"codes":"C/33","pl":"Badania chemiczne – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Chemical tests – working environment (harmful factors – air)"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, drgania, mikroklimat","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nusance factors – noise, vibrations, microclimate)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne - hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise)"},{"codes":"N/33P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Tests of physical properties and sampling – working environment (harmful factors – air)"},{"codes":"P/33","pl":"Pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Sampling – working environment (harmful factors – air)"},{"codes":"P/35","pl":"Pobieranie próbek – Pomieszczenia (warunki środowiskowe)","en":"Sampling – Facilities (environmental conditions)"}],"issue":{"no":"9","date":"11.06.2026"},"parse_date":"2026-08-13T08:03:10.500Z","parse_source":"agent-claude-code","map_coord":[50.668345,17.937164],"map_geo":"nominatim-street","lab_locations":[{"name":"PROLAB Sp. z o.o. - Laboratorium","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/576bbe7626935f681c2850ea5fea861a/AB%201721.pdf","has_en":true,"category_counts":{"environment":20,"construction":2,"materials":1},"category_scores":{"environment":17.39,"construction":0.17,"materials":0.04},"has_zh":true,"lab_locations_zh":[{"name":"PROLAB Sp. z o.o. — 实验室","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d7a3e0636ba417e41b317","lab_id":"69ad52a3de79e566650fb913","country":"PL","accr_number":"AB 1721","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(40 – 136) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(52 – 138) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (40 – 136) dB\nSzczytowy poziom dźwięku C\nZakres (52 – 138) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 – punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 – punkt 11"],"lab_section":"PROLAB Sp. z o.o. - Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (40 – 136) dB\nSzczytowy poziom dźwięku C\nZakres (52 – 138) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 – punkt 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (40 – 136) dB\nSzczytowy poziom dzwieku C\nZakres (52 – 138) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 - punkt 10 i strategie 3 – punkt 11","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"PROLAB Sp. z o.o. - Laboratory","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(40 – 136) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(52 – 138) dB"}],"search_en":"Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method PROLAB Sp. z o.o. - Laboratory Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 – punkt 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(40 – 136) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(52 – 138) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 PROLAB Sp. z o.o. — 实验室 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 – punkt 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"PROLAB Sp. z o.o. — 实验室"},{"_id":"6a7d7a3e0636ba417e41b318","lab_id":"69ad52a3de79e566650fb913","country":"PL","accr_number":"AB 1721","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 – punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 – punkt 11"],"lab_section":"PROLAB Sp. z o.o. - Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 – punkt 11 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 - punkt 10 i strategie 3 – punkt 11","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"PROLAB Sp. z o.o. - Laboratory","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment – noise Noise exposure level referred to: PROLAB Sp. z o.o. - Laboratory an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 – punkt 11","test_object_en":"Workplace environment – noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： PROLAB Sp. z o.o. — 实验室 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 – punkt 11","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"PROLAB Sp. z o.o. — 实验室"},{"_id":"6a7d7a3e0636ba417e41b319","lab_id":"69ad52a3de79e566650fb913","country":"PL","accr_number":"AB 1721","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"},{"name":"metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002 + Az1:2004"],"lab_section":"PROLAB Sp. z o.o. - Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nmetale i ich zwiazki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002 + Az1:2004","categories":["materials","environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"PROLAB Sp. z o.o. - Laboratory","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents – inhalable fraction – respirable fraction"},{"name":"metals and their compounds, including – inhalable fraction – respirable fraction"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Personal dosimetry method PROLAB Sp. z o.o. - Laboratory dust agents – inhalable fraction – respirable fraction metals and their compounds, including – inhalable fraction – respirable fraction PN-Z-04008-7:2002 | PN-Z-04008-7:2002 + Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment – air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 PROLAB Sp. z o.o. — 实验室 粉尘因素 — 可吸入组分 — 呼吸性组分 金属及其化合物，包括 — 可吸入组分 — 呼吸性组分 PN-Z-04008-7:2002 | PN-Z-04008-7:2002 + Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"},{"name":"金属及其化合物，包括 — 可吸入组分 — 呼吸性组分"}],"lab_section_zh":"PROLAB Sp. z o.o. — 实验室"},{"_id":"6a7d7a3e0636ba417e41b31a","lab_id":"69ad52a3de79e566650fb913","country":"PL","accr_number":"AB 1721","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"substancje organiczne,"},{"name":"substancje nieorganiczne, w tym – frakcja wdychalna – frakcja torakalna – frakcja respirabilna"},{"name":"respirabilne włókna azbestu"}],"technique":"Metoda stacjonarna; Metoda dozymetrii indywidualnej","techniques":["Metoda stacjonarna","Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne,\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja torakalna – frakcja respirabilna\nrespirabilne włókna azbestu\nMetoda stacjonarna; Metoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002 + Az1:2004"],"lab_section":"PROLAB Sp. z o.o. - Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne,\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja torakalna – frakcja respirabilna\nrespirabilne włókna azbestu\nMetoda stacjonarna; Metoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nsubstancje organiczne,\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja torakalna – frakcja respirabilna\nrespirabilne wlokna azbestu\nMetoda stacjonarna; Metoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002 + Az1:2004","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"PROLAB Sp. z o.o. - Laboratory","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"organic substances,"},{"name":"inorganic substances, including – inhalable fraction – thoracic fraction – respirable fraction"},{"name":"respirable asbestos fibres"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Stationary method; Personal dosimetry method PROLAB Sp. z o.o. - Laboratory organic substances, inorganic substances, including – inhalable fraction – thoracic fraction – respirable fraction respirable asbestos fibres PN-Z-04008-7:2002 | PN-Z-04008-7:2002 + Az1:2004","technique_en":"Stationary method; Personal dosimetry method","test_object_en":"Workplace environment – air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 定点法；个体剂量测定法 PROLAB Sp. z o.o. — 实验室 有机物质， 无机物质，其中包括 － 可吸入性粉尘 － 胸腔性粉尘 － 呼吸性粉尘 可吸入石棉纤维 PN-Z-04008-7:2002 | PN-Z-04008-7:2002 + Az1:2004","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"PROLAB Sp. z o.o. — 实验室","parameters_zh":[{"name":"有机物质，"},{"name":"无机物质，其中包括 － 可吸入性粉尘 － 胸腔性粉尘 － 呼吸性粉尘"},{"name":"可吸入石棉纤维"}],"technique_zh":"定点法；个体剂量测定法"},{"_id":"6a7d7a3e0636ba417e41b31b","lab_id":"69ad52a3de79e566650fb913","country":"PL","accr_number":"AB 1721","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002 + Az1:2004"],"lab_section":"PROLAB Sp. z o.o. - Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 | PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 | PN-Z-04008-7:2002 + Az1:2004","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"PROLAB Sp. z o.o. - Laboratory","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment – air Exposure index (calculated) PROLAB Sp. z o.o. - Laboratory PN-Z-04008-7:2002 | PN-Z-04008-7:2002 + Az1:2004","test_object_en":"Workplace environment – air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PROLAB Sp. z o.o. — 实验室 PN-Z-04008-7:2002 | PN-Z-04008-7:2002 + Az1:2004","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"PROLAB Sp. z o.o. — 实验室"},{"_id":"6a7d7a3e0636ba417e41b31c","lab_id":"69ad52a3de79e566650fb913","country":"PL","accr_number":"AB 1721","accr_body":"PCA","test_object":"Pomieszczenia przeznaczone na pobyt ludzi - powietrze","methodology":"Pobieranie próbek do oznaczenia stężenia związków organicznych i formaldehydu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczenia stężenia związków organicznych i formaldehydu","reference":"PB-02 wydanie 2 z 27.06.2024","norm_bases":["PB-02 wydanie 2 z 27.06.2024"],"lab_section":"PROLAB Sp. z o.o. - Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia przeznaczone na pobyt ludzi - powietrze Pobieranie próbek do oznaczenia stężenia związków organicznych i formaldehydu PB-02 wydanie 2 z 27.06.2024 Pomieszczenia przeznaczone na pobyt ludzi - powietrze Pobieranie probek do oznaczenia stezenia zwiazkow organicznych i formaldehydu PB-02 wydanie 2 z 27.06.2024","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"PROLAB Sp. z o.o. - Laboratory","methodology_en":"Sampling for determination of the concentration of organic compounds and formaldehyde","search_en":"Rooms intended for human occupancy - air Sampling for determination of the concentration of organic compounds and formaldehyde PROLAB Sp. z o.o. - Laboratory PB-02 wydanie 2 z 27.06.2024","test_object_en":"Rooms intended for human occupancy - air","lab_section_zh":"PROLAB Sp. z o.o. — 实验室","search_zh":"供人员停留的房间 － 空气 PROLAB Sp. z o.o. — 实验室 PB-02 wydanie 2 z 27.06.2024","test_object_zh":"供人员停留的房间 － 空气"},{"_id":"6a7d7a3e0636ba417e41b31d","lab_id":"69ad52a3de79e566650fb913","country":"PL","accr_number":"AB 1721","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:","parameters":[{"name":"Asfalt naftowy"},{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Sadza techniczna"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,19 – 27,7) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,19 – 27,7) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"PROLAB Sp. z o.o. - Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,19 – 27,7) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,19 – 27,7) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"PROLAB Sp. z o.o. - Laboratory","methodology_en":"Concentration of harmful dust agents - inhalable fraction:","parameters_en":[{"name":"Petroleum bitumen"},{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Carbon black"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Range","range":"(0,19 – 27,7) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents - inhalable fraction: Gravimetric method PROLAB Sp. z o.o. - Laboratory Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"石油沥青"},{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,19 – 27,7) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分： 重量法 PROLAB Sp. z o.o. — 实验室 石油沥青 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分：","lab_section_zh":"PROLAB Sp. z o.o. — 实验室"},{"_id":"6a7d7a3e0636ba417e41b31e","lab_id":"69ad52a3de79e566650fb913","country":"PL","accr_number":"AB 1721","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,10 – 14,6) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,10 – 14,6) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"PROLAB Sp. z o.o. - Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,10 – 14,6) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nTalk\nWegiel (kamienny, brunatny)\nZakres (0,10 – 14,6) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"PROLAB Sp. z o.o. - Laboratory","methodology_en":"Concentration of harmful dust agents - respirable fraction:","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,10 – 14,6) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents - respirable fraction: Gravimetric method PROLAB Sp. z o.o. - Laboratory Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,10 – 14,6) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分： 重量法 PROLAB Sp. z o.o. — 实验室 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"PROLAB Sp. z o.o. — 实验室","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分："},{"_id":"6a7d7a3e0636ba417e41b31f","lab_id":"69ad52a3de79e566650fb913","country":"PL","accr_number":"AB 1721","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie gazów:","parameters":[{"name":"CO","range":"(2,5 – 250) mg/m3"},{"name":"NO","range":"(0,268 – 18,00) mg/m3"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie gazów:\nZakres:\nCO (2,5 – 250) mg/m3\nNO (0,268 – 18,00) mg/m3\nMetoda elektrochemiczna","reference":"PB-01 wydanie 1 z dnia 20.12.2018 r. | PB-01 wydanie 1 z dnia 20.12.2018 r.","norm_bases":["PB-01 wydanie 1 z dnia 20.12.2018 r.","PB-01 wydanie 1 z dnia 20.12.2018 r."],"lab_section":"PROLAB Sp. z o.o. - Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie gazów:\nZakres:\nCO (2,5 – 250) mg/m3\nNO (0,268 – 18,00) mg/m3\nMetoda elektrochemiczna PB-01 wydanie 1 z dnia 20.12.2018 r. | PB-01 wydanie 1 z dnia 20.12.2018 r. Srodowisko pracy – powietrze Stezenie gazow:\nZakres:\nCO (2,5 – 250) mg/m3\nNO (0,268 – 18,00) mg/m3\nMetoda elektrochemiczna PB-01 wydanie 1 z dnia 20.12.2018 r. | PB-01 wydanie 1 z dnia 20.12.2018 r.","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"PROLAB Sp. z o.o. - Laboratory","methodology_en":"Gas concentrations:","parameters_en":[{"name":"CO","range":"(2,5 – 250) mg/m3"},{"name":"NO","range":"(0,268 – 18,00) mg/m3"}],"search_en":"Workplace environment – air Gas concentrations: Electrochemical method PROLAB Sp. z o.o. - Laboratory CO NO PB-01 wydanie 1 z dnia 20.12.2018 r. | PB-01 wydanie 1 z dnia 20.12.2018 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment – air","search_zh":"工作场所环境 — 空气 气体浓度： 电化学法 PROLAB Sp. z o.o. — 实验室 CO NO PB-01 wydanie 1 z dnia 20.12.2018 r. | PB-01 wydanie 1 z dnia 20.12.2018 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"CO","range":"(2,5 – 250) mg/m3"},{"name":"NO","range":"(0,268 – 18,00) mg/m3"}],"lab_section_zh":"PROLAB Sp. z o.o. — 实验室","methodology_zh":"气体浓度："},{"_id":"6a7d7a3e0636ba417e41b320","lab_id":"69ad52a3de79e566650fb913","country":"PL","accr_number":"AB 1721","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PB-01 wydanie 1 z dnia 20.12.2018 r. | PB-01 wydanie 1 z dnia 20.12.2018 r.","norm_bases":["PB-01 wydanie 1 z dnia 20.12.2018 r.","PB-01 wydanie 1 z dnia 20.12.2018 r."],"lab_section":"PROLAB Sp. z o.o. - Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PB-01 wydanie 1 z dnia 20.12.2018 r. | PB-01 wydanie 1 z dnia 20.12.2018 r. Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PB-01 wydanie 1 z dnia 20.12.2018 r. | PB-01 wydanie 1 z dnia 20.12.2018 r.","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"PROLAB Sp. z o.o. - Laboratory","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment – air Exposure index (calculated) PROLAB Sp. z o.o. - Laboratory PB-01 wydanie 1 z dnia 20.12.2018 r. | PB-01 wydanie 1 z dnia 20.12.2018 r.","test_object_en":"Workplace environment – air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PROLAB Sp. z o.o. — 实验室 PB-01 wydanie 1 z dnia 20.12.2018 r. | PB-01 wydanie 1 z dnia 20.12.2018 r.","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"PROLAB Sp. z o.o. — 实验室"},{"_id":"6a7d7a3e0636ba417e41b321","lab_id":"69ad52a3de79e566650fb913","country":"PL","accr_number":"AB 1721","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,01 - 50) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,01 - 50) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"PROLAB Sp. z o.o. - Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,01 - 50) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,01 - 50) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"PROLAB Sp. z o.o. - Laboratory","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,01 - 50) m/s2"}],"search_en":"Workplace environment – whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method PROLAB Sp. z o.o. - Laboratory Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment – whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,01 - 50) m/s2"}],"search_zh":"工作场所环境 — 全身振动 频率计权振动加速度有效值 直接测量法 PROLAB Sp. z o.o. — 实验室 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动","lab_section_zh":"PROLAB Sp. z o.o. — 实验室"},{"_id":"6a7d7a3e0636ba417e41b322","lab_id":"69ad52a3de79e566650fb913","country":"PL","accr_number":"AB 1721","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8– godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4 awx, 1.4 awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4 awx, 1.4 awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8– godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4 awx, 1.4 awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4 awx, 1.4 awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"PROLAB Sp. z o.o. - Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8– godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4 awx, 1.4 awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4 awx, 1.4 awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8– godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4 awx, 1.4 awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4 awx, 1.4 awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"PROLAB Sp. z o.o. - Laboratory","methodology_en":"Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4 awx, 1.4 awy, awz), Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4 awx, 1.4 awy, awz) (calculated)","search_en":"Workplace environment – whole-body vibration Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4 awx, 1.4 awy, awz), Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4 awx, 1.4 awy, awz) (calculated) PROLAB Sp. z o.o. - Laboratory PN-EN 14253+A1:2011","test_object_en":"Workplace environment – whole-body vibration","search_zh":"工作场所环境 — 全身振动 PROLAB Sp. z o.o. — 实验室 PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动","lab_section_zh":"PROLAB Sp. z o.o. — 实验室"},{"_id":"6a7d7a3e0636ba417e41b323","lab_id":"69ad52a3de79e566650fb913","country":"PL","accr_number":"AB 1721","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,1 – 500) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,1 – 500) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"PROLAB Sp. z o.o. - Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,1 – 500) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,1 – 500) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"PROLAB Sp. z o.o. - Laboratory","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,1 – 500) m/s2"}],"search_en":"Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method PROLAB Sp. z o.o. - Laboratory Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,1 – 500) m/s2"}],"search_zh":"工作场所环境 — 手传振动 频率计权振动加速度有效值 直接测量法 PROLAB Sp. z o.o. — 实验室 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动","lab_section_zh":"PROLAB Sp. z o.o. — 实验室"},{"_id":"6a7d7a3e0636ba417e41b324","lab_id":"69ad52a3de79e566650fb913","country":"PL","accr_number":"AB 1721","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)., Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)., Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"PROLAB Sp. z o.o. - Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)., Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz)., Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"PROLAB Sp. z o.o. - Laboratory","methodology_en":"Daily exposure, expressed as the energy-equivalent for 8 hours of action vector sum of root-mean-square, frequency-corrected vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz)., Exposure lasting 30 minutes and less, expressed as the vector sum of root-mean-square, frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment – hand-arm vibration Daily exposure, expressed as the energy-equivalent for 8 hours of action vector sum of root-mean-square, frequency-corrected vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz)., Exposure lasting 30 minutes and less, expressed as the vector sum of root-mean-square, frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated) PROLAB Sp. z o.o. - Laboratory PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_en":"Workplace environment – hand-arm vibration","search_zh":"工作场所环境 — 手传振动 日暴露量，以三个方向分量所测定的频率计权有效振动加速度矢量和的8小时能量等效值表示 PROLAB Sp. z o.o. — 实验室 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 — 手传振动","lab_section_zh":"PROLAB Sp. z o.o. — 实验室","methodology_zh":"日暴露量，以三个方向分量所测定的频率计权有效振动加速度矢量和的8小时能量等效值表示"},{"_id":"6a7d7a3e0636ba417e41b325","lab_id":"69ad52a3de79e566650fb913","country":"PL","accr_number":"AB 1721","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25,0 – 90,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (25,0 – 90,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. 2023 poz. 1706) z wyłączeniem punktu F.","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. 2023 poz. 1706) z wyłączeniem punktu F."],"lab_section":"PROLAB Sp. z o.o. - Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (25,0 – 90,0) dB\nMetoda pomiarowa bezpośrednia Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. 2023 poz. 1706) z wyłączeniem punktu F. Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (25,0 – 90,0) dB\nMetoda pomiarowa bezposrednia Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (tj. Dz. U. 2023 poz. 1706) z wylaczeniem punktu F.","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"PROLAB Sp. z o.o. - Laboratory","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(25,0 – 90,0) dB"}],"search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method PROLAB Sp. z o.o. - Laboratory Range Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. 2023 poz. 1706) z wyłączeniem punktu F.","technique_en":"Direct measurement method","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(25,0 – 90,0) dB"}],"search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 A 计权等效声级 直接测量法 PROLAB Sp. z o.o. — 实验室 范围 Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. 2023 poz. 1706) z wyłączeniem punktu F.","technique_zh":"直接测量法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声","lab_section_zh":"PROLAB Sp. z o.o. — 实验室"},{"_id":"6a7d7a3e0636ba417e41b326","lab_id":"69ad52a3de79e566650fb913","country":"PL","accr_number":"AB 1721","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czsu odniesienia T wyrażony wskaźnikami, LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czsu odniesienia T wyrażony wskaźnikami, LAeqD i LAeqN (z obliczeń)","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. 2023 poz. 1706) z wyłączeniem punktu F.","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. 2023 poz. 1706) z wyłączeniem punktu F."],"lab_section":"PROLAB Sp. z o.o. - Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czsu odniesienia T wyrażony wskaźnikami, LAeqD i LAeqN (z obliczeń) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. 2023 poz. 1706) z wyłączeniem punktu F. Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czsu odniesienia T wyrazony wskaznikami, LAeqD i LAeqN (z obliczen) Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (tj. Dz. U. 2023 poz. 1706) z wylaczeniem punktu F.","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"PROLAB Sp. z o.o. - Laboratory","methodology_en":"A-weighted equivalent sound level for the reference time T expressed by the indicators, LAeqD and LAeqN (calculated)","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound level for the reference time T expressed by the indicators, LAeqD and LAeqN (calculated) PROLAB Sp. z o.o. - Laboratory Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. 2023 poz. 1706) z wyłączeniem punktu F.","test_object_en":"General environment – noise from installations, equipment and industrial plants","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 PROLAB Sp. z o.o. — 实验室 Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. 2023 poz. 1706) z wyłączeniem punktu F.","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声","lab_section_zh":"PROLAB Sp. z o.o. — 实验室"},{"_id":"6a7d7a3e0636ba417e41b327","lab_id":"69ad52a3de79e566650fb913","country":"PL","accr_number":"AB 1721","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 – 60) oC"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(10 – 60) oC"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 60) oC"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 60) oC\nTemperatura wilgotna naturalna\nZakres (10 – 60) oC\nTemperatura poczernionej kuli\nZakres (10 – 60) oC\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"PROLAB Sp. z o.o. - Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (10 – 60) oC\nTemperatura wilgotna naturalna\nZakres (10 – 60) oC\nTemperatura poczernionej kuli\nZakres (10 – 60) oC\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy – mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (10 – 60) oC\nTemperatura wilgotna naturalna\nZakres (10 – 60) oC\nTemperatura poczernionej kuli\nZakres (10 – 60) oC\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"PROLAB Sp. z o.o. - Laboratory","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 – 60) oC"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(10 – 60) oC"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 – 60) oC"}],"search_en":"Workplace environment – hot microclimate Air temperature Direct measurement method PROLAB Sp. z o.o. - Laboratory Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 60) oC"},{"name":"自然湿球温度"},{"name":"范围","range":"(10 – 60) oC"},{"name":"黑球温度"},{"name":"范围","range":"(10 – 60) oC"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 PROLAB Sp. z o.o. — 实验室 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候","lab_section_zh":"PROLAB Sp. z o.o. — 实验室"},{"_id":"6a7d7a3e0636ba417e41b328","lab_id":"69ad52a3de79e566650fb913","country":"PL","accr_number":"AB 1721","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"PROLAB Sp. z o.o. - Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy – mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"PROLAB Sp. z o.o. - Laboratory","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"Workplace environment – hot microclimate WBGT index, WBGTeff index (calculated) PROLAB Sp. z o.o. - Laboratory PN-EN ISO 7243:2018-01","test_object_en":"Workplace environment – hot microclimate","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PROLAB Sp. z o.o. — 实验室 PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 — 高温微气候","lab_section_zh":"PROLAB Sp. z o.o. — 实验室"},{"_id":"6a7d7a3e0636ba417e41b329","lab_id":"69ad52a3de79e566650fb913","country":"PL","accr_number":"AB 1721","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(- 30 – 10) oC"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(- 30 – 10) oC"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(25 – 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (- 30 – 10) oC\nTemperatura poczernionej kuli\nZakres (- 30 – 10) oC\nWilgotność powietrza\nZakres (25 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079: 2008","norm_bases":["PN-EN ISO 11079: 2008"],"lab_section":"PROLAB Sp. z o.o. - Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (- 30 – 10) oC\nTemperatura poczernionej kuli\nZakres (- 30 – 10) oC\nWilgotność powietrza\nZakres (25 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079: 2008 Srodowisko pracy – mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (- 30 – 10) oC\nTemperatura poczernionej kuli\nZakres (- 30 – 10) oC\nWilgotnosc powietrza\nZakres (25 – 90) %\nPredkosc powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079: 2008","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"PROLAB Sp. z o.o. - Laboratory","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(- 30 – 10) oC"},{"name":"Black globe temperature"},{"name":"Range","range":"(- 30 – 10) oC"},{"name":"Air humidity"},{"name":"Range","range":"(25 – 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 5,0) m/s"}],"search_en":"Workplace environment – cold microclimate Air temperature Direct measurement method PROLAB Sp. z o.o. - Laboratory Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079: 2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment – cold microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(- 30 – 10) oC"},{"name":"黑球温度"},{"name":"范围","range":"(- 30 – 10) oC"},{"name":"空气湿度"},{"name":"范围","range":"(25 – 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 5,0) m/s"}],"search_zh":"工作场所环境 — 低温微气候 空气温度 直接测量法 PROLAB Sp. z o.o. — 实验室 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079: 2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 低温微气候","lab_section_zh":"PROLAB Sp. z o.o. — 实验室"},{"_id":"6a7d7a3e0636ba417e41b32a","lab_id":"69ad52a3de79e566650fb913","country":"PL","accr_number":"AB 1721","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","reference":"PN-EN ISO 11079: 2008","norm_bases":["PN-EN ISO 11079: 2008"],"lab_section":"PROLAB Sp. z o.o. - Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń) PN-EN ISO 11079: 2008 Srodowisko pracy – mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutral, Wskaznik twc (z obliczen) PN-EN ISO 11079: 2008","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"PROLAB Sp. z o.o. - Laboratory","methodology_en":"IREQmin index, IREQneutral index, twc index (calculated)","search_en":"Workplace environment – cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PROLAB Sp. z o.o. - Laboratory PN-EN ISO 11079: 2008","test_object_en":"Workplace environment – cold microclimate","search_zh":"工作场所环境 — 低温微气候 IREQmin 指数、IREQneutral 指数、twc 指数（计算值） PROLAB Sp. z o.o. — 实验室 PN-EN ISO 11079: 2008","test_object_zh":"工作场所环境 — 低温微气候","methodology_zh":"IREQmin 指数、IREQneutral 指数、twc 指数（计算值）","lab_section_zh":"PROLAB Sp. z o.o. — 实验室"}],"has_pdf":true}