{"lab":{"_id":"69ad52a3de79e566650fb911","accr_number":"AB 1719","country":"PL","accr_body":"PCA","address":"KATARZYNA LUBIAK, ul. Osiedlowa 8, 33-370 Powroźnik","categories":["water","microbiology"],"city":"Powroźnik","imported_at":"2026-03-08T10:42:43.265Z","methods_count":46,"name":"LABORATORIUM AQUA-CRISTAL","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1719.pdf"],"scope_summary":"","search_text":"laboratorium aqua-cristal katarzyna lubiak, ul. osiedlowa 8, 33-370 powroźnik water other pharma electronics microbiology automotive","status":"active","updated_at":"2026-03-08T14:50:50.928Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:50.928Z","email_confidence":"high","email_mx":true,"email_source":"https://laboratorium-cristal.pl/kontakt/","fields_of_testing":[{"codes":"C/28/P; C/29/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Chemical tests and sampling of water, drinking water"},{"codes":"C/22","pl":"Badania chemiczne żywności","en":"Chemical tests of food"},{"codes":"N/28/P; N/29/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Tests of physical properties and sampling of water, drinking water"},{"codes":"N/22","pl":"Badania właściwości fizycznych żywności","en":"Tests of physical properties of food"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"},{"codes":"K/22","pl":"Badania mikrobiologiczne żywności","en":"Microbiological tests of food"}],"issue":{"no":"7","date":"19.01.2026"},"parse_date":"2026-07-20T19:34:22.192Z","parse_source":"script-pdfplumber","map_coord":[49.370129,20.946291],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":46,"microbiology":6},"category_scores":{"water":40.69,"microbiology":0.69},"has_zh":true},"methods":[{"_id":"6a5e783e4cc76d93cba39ad8","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters":[{"name":"Zakres","range":"(2,0 – 50,0) °C"}],"parameters_en":[{"name":"Range","range":"(2,0 – 50,0) °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (2,0 – 50,0) °C","reference":"PBL-22 wyd. II z dnia 14.07.2021 r. PBL-15 wyd. II z dnia 02.02.2018 r.","norm_bases":["PBL-22 wyd. II z dnia 14.07.2021 r. PBL-15 wyd. II z dnia 02.02.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (2,0 – 50,0) °C PBL-22 wyd. II z dnia 14.07.2021 r. PBL-15 wyd. II z dnia 02.02.2018 r. Woda na plywalniach Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (2,0 – 50,0) °C PBL-22 wyd. II z dnia 14.07.2021 r. PBL-15 wyd. II z dnia 02.02.2018 r.","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Sampling for chemical and physical testing Temperature of the water sample taken Range PBL-22 wyd. II z dnia 14.07.2021 r. PBL-15 wyd. II z dnia 02.02.2018 r.","parameters_zh":[{"name":"范围","range":"(2,0 – 50,0) °C"}],"search_zh":"游泳池水 化学和物理检测采样 所采水样的温度 范围 PBL-22 wyd. II z dnia 14.07.2021 r. PBL-15 wyd. II z dnia 02.02.2018 r.","test_object_zh":"游泳池水","methodology_zh":"化学和物理检测采样 所采水样的温度"},{"_id":"6a5e783e4cc76d93cba39ad9","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl","methodology_en":"Oxidation-reduction (redox) potential vs. Ag/AgCl 3,5 mol/l KCl","parameters":[{"name":"Zakres","range":"(200 – 1000) mV"}],"parameters_en":[{"name":"Range","range":"(200 – 1000) mV"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (200 – 1000) mV\nMetoda potencjometryczna","reference":"PBL-12 wyd. II z dnia 31.01.2018 r.","norm_bases":["PBL-12 wyd. II z dnia 31.01.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (200 – 1000) mV\nMetoda potencjometryczna PBL-12 wyd. II z dnia 31.01.2018 r. Woda na plywalniach Potencjal utleniajaco-redukujacy (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (200 – 1000) mV\nMetoda potencjometryczna PBL-12 wyd. II z dnia 31.01.2018 r.","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Oxidation-reduction (redox) potential vs. Ag/AgCl 3,5 mol/l KCl Potentiometric method Range PBL-12 wyd. II z dnia 31.01.2018 r.","parameters_zh":[{"name":"范围","range":"(200 – 1000) mV"}],"search_zh":"游泳池水 氧化还原电位（redoks），相对于 Ag/AgCl 3,5 mol/l KCl 电位法 范围 PBL-12 wyd. II z dnia 31.01.2018 r.","technique_zh":"电位法","test_object_zh":"游泳池水","methodology_zh":"氧化还原电位（redoks），相对于 Ag/AgCl 3,5 mol/l KCl"},{"_id":"6a5e783e4cc76d93cba39ada","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,00 – 9,00"}],"parameters_en":[{"name":"Range","range":"4,00 – 9,00"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,00 – 9,00\nMetoda potencjometryczna","reference":"P N - E N I S O 1 0 5 2 3 : 2 0 1 2","norm_bases":["P N - E N I S O 1 0 5 2 3 : 2 0 1 2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach pH\nZakres 4,00 – 9,00\nMetoda potencjometryczna P N - E N I S O 1 0 5 2 3 : 2 0 1 2 Woda na plywalniach pH\nZakres 4,00 – 9,00\nMetoda potencjometryczna P N - E N I S O 1 0 5 2 3 : 2 0 1 2","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water pH Potentiometric method Range P N - E N I S O 1 0 5 2 3 : 2 0 1 2","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,00 – 9,00"}],"search_zh":"游泳池水 pH 值 电位法 范围 P N - E N I S O 1 0 5 2 3 : 2 0 1 2","technique_zh":"电位法","test_object_zh":"游泳池水"},{"_id":"6a5e783e4cc76d93cba39adb","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody","methodology_en":"Sampling for chemical and physical testing Water temperature","parameters":[{"name":"Zakres","range":"(2,0 – 50,0) °C"}],"parameters_en":[{"name":"Range","range":"(2,0 – 50,0) °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody\nZakres (2,0 – 50,0) °C","reference":"PN-ISO 5667-5:2017-10 PBL-15 wyd. II z dnia 02.02.2018 r.","norm_bases":["PN-ISO 5667-5:2017-10 PBL-15 wyd. II z dnia 02.02.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody\nZakres (2,0 – 50,0) °C PN-ISO 5667-5:2017-10 PBL-15 wyd. II z dnia 02.02.2018 r. Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura wody\nZakres (2,0 – 50,0) °C PN-ISO 5667-5:2017-10 PBL-15 wyd. II z dnia 02.02.2018 r.","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for chemical and physical testing Water temperature Range PN-ISO 5667-5:2017-10 PBL-15 wyd. II z dnia 02.02.2018 r.","parameters_zh":[{"name":"范围","range":"(2,0 – 50,0) °C"}],"search_zh":"生活饮用水 用于化学与物理检验的采样 水温 范围 PN-ISO 5667-5:2017-10 PBL-15 wyd. II z dnia 02.02.2018 r.","test_object_zh":"生活饮用水","methodology_zh":"用于化学与物理检验的采样 水温"},{"_id":"6a5e783e4cc76d93cba39adc","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(2 – 250) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(2 – 250) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (2 – 250) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (2 – 250) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C Woda, Woda do spozycia przez ludzi Barwa\nZakres (2 – 250) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2 – 250) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783e4cc76d93cba39add","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","test_object_en":"Water intended for human consumption, Swimming pool water","methodology":"Stężenie chloru wolnego","methodology_en":"Free chlorine concentration","parameters":[{"name":"Zakres","range":"(0,02 – 2,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,02 – 2,00) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"technique_en":"Colorimetric method","computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego\nZakres (0,02 – 2,00) mg/l\nMetoda kolorymetryczna","reference":"P B L - 1 7 w y d . I I z d n i a 02.02.2018 r. | na podstawie testu Hach Lange nr 2105560","norm_bases":["P B L - 1 7 w y d . I I z d n i a 02.02.2018 r.","na podstawie testu Hach Lange nr 2105560"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Stężenie chloru wolnego\nZakres (0,02 – 2,00) mg/l\nMetoda kolorymetryczna P B L - 1 7 w y d . I I z d n i a 02.02.2018 r. | na podstawie testu Hach Lange nr 2105560 Woda do spozycia przez ludzi, Woda na plywalniach Stezenie chloru wolnego\nZakres (0,02 – 2,00) mg/l\nMetoda kolorymetryczna P B L - 1 7 w y d . I I z d n i a 02.02.2018 r. | na podstawie testu Hach Lange nr 2105560","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Swimming pool water Free chlorine concentration Colorimetric method Range P B L - 1 7 w y d . I I z d n i a 02.02.2018 r. | na podstawie testu Hach Lange nr 2105560","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 2,00) mg/l"}],"search_zh":"生活饮用水、游泳池水 游离氯浓度 比色法 范围 P B L - 1 7 w y d . I I z d n i a 02.02.2018 r. | na podstawie testu Hach Lange nr 2105560","technique_zh":"比色法","test_object_zh":"生活饮用水、游泳池水"},{"_id":"6a5e783e4cc76d93cba39ade","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","test_object_en":"Water intended for human consumption, Swimming pool water","methodology":"Stężenie chloru całkowitego","methodology_en":"Total chlorine concentration","parameters":[{"name":"Zakres","range":"(0,04 – 2,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,04 – 2,00) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"technique_en":"Colorimetric method","computed":[],"computed_en":[],"activity":"Stężenie chloru całkowitego\nZakres (0,04 – 2,00) mg/l\nMetoda kolorymetryczna","reference":"P B L - 1 8 w y d . I I z dnia 31.01.2018 r. na podstawie testu Hach Lange nr 2105660","norm_bases":["P B L - 1 8 w y d . I I z dnia 31.01.2018 r. na podstawie testu Hach Lange nr 2105660"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Stężenie chloru całkowitego\nZakres (0,04 – 2,00) mg/l\nMetoda kolorymetryczna P B L - 1 8 w y d . I I z dnia 31.01.2018 r. na podstawie testu Hach Lange nr 2105660 Woda do spozycia przez ludzi, Woda na plywalniach Stezenie chloru calkowitego\nZakres (0,04 – 2,00) mg/l\nMetoda kolorymetryczna P B L - 1 8 w y d . I I z dnia 31.01.2018 r. na podstawie testu Hach Lange nr 2105660","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Swimming pool water Total chlorine concentration Colorimetric method Range P B L - 1 8 w y d . I I z dnia 31.01.2018 r. na podstawie testu Hach Lange nr 2105660","parameters_zh":[{"name":"范围","range":"(0,04 – 2,00) mg/l"}],"search_zh":"生活饮用水、游泳池水 总氯浓度 比色法 范围 P B L - 1 8 w y d . I I z dnia 31.01.2018 r. na podstawie testu Hach Lange nr 2105660","technique_zh":"比色法","test_object_zh":"生活饮用水、游泳池水","methodology_zh":"总氯浓度"},{"_id":"6a5e783e4cc76d93cba39adf","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","test_object_en":"Water intended for human consumption, Swimming pool water","methodology":"Stężenie chloru związanego (z obliczeń)","methodology_en":"Combined chlorine concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru związanego (z obliczeń)","reference":"P B L - 1 4 wyd. II z dnia 31.01.2018 r.","norm_bases":["P B L - 1 4 wyd. II z dnia 31.01.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Stężenie chloru związanego (z obliczeń) P B L - 1 4 wyd. II z dnia 31.01.2018 r. Woda do spozycia przez ludzi, Woda na plywalniach Stezenie chloru zwiazanego (z obliczen) P B L - 1 4 wyd. II z dnia 31.01.2018 r.","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Swimming pool water Combined chlorine concentration (calculated) P B L - 1 4 wyd. II z dnia 31.01.2018 r.","methodology_zh":"化合氯浓度（计算值）","search_zh":"生活饮用水、游泳池水 化合氯浓度（计算值） P B L - 1 4 wyd. II z dnia 31.01.2018 r.","test_object_zh":"生活饮用水、游泳池水"},{"_id":"6a5e783e4cc76d93cba39ae0","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","test_object_en":"Water intended for human consumption, Swimming pool water","methodology":"Stężenie glinu","methodology_en":"Aluminium concentration","parameters":[{"name":"Zakres","range":"(20 – 500) μg/l"}],"parameters_en":[{"name":"Range","range":"(20 – 500) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie glinu\nZakres (20 – 500) μg/l\nMetoda spektrofotometryczna","reference":"PBL-10 wyd. I z dnia 29.01.2018 r. | na podstawie testu HACH LANGE nr LCK 301","norm_bases":["PBL-10 wyd. I z dnia 29.01.2018 r.","na podstawie testu HACH LANGE nr LCK 301"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Stężenie glinu\nZakres (20 – 500) μg/l\nMetoda spektrofotometryczna PBL-10 wyd. I z dnia 29.01.2018 r. | na podstawie testu HACH LANGE nr LCK 301 Woda do spozycia przez ludzi, Woda na plywalniach Stezenie glinu\nZakres (20 – 500) μg/l\nMetoda spektrofotometryczna PBL-10 wyd. I z dnia 29.01.2018 r. | na podstawie testu HACH LANGE nr LCK 301","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Swimming pool water Aluminium concentration Spectrophotometric method Range PBL-10 wyd. I z dnia 29.01.2018 r. | na podstawie testu HACH LANGE nr LCK 301","parameters_zh":[{"name":"范围","range":"(20 – 500) μg/l"}],"search_zh":"生活饮用水、游泳池水 铝浓度 分光光度法 范围 PBL-10 wyd. I z dnia 29.01.2018 r. | na podstawie testu HACH LANGE nr LCK 301","technique_zh":"分光光度法","methodology_zh":"铝浓度","test_object_zh":"生活饮用水、游泳池水"},{"_id":"6a5e783e4cc76d93cba39ae1","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","test_object_en":"Water intended for human consumption, Swimming pool water","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,1 – 20,00) NTU"}],"parameters_en":[{"name":"Range","range":"(0,1 – 20,00) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,1 – 20,00) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Mętność\nZakres (0,1 – 20,00) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi, Woda na plywalniach Metnosc\nZakres (0,1 – 20,00) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Swimming pool water Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,1 – 20,00) NTU"}],"search_zh":"生活饮用水、游泳池水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水、游泳池水"},{"_id":"6a5e783e4cc76d93cba39ae2","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","test_object_en":"Water intended for human consumption, Swimming pool water","methodology":"Indeks nadmanganiowy (utlenialność)","methodology_en":"Permanganate index (oxidisability)","parameters":[{"name":"Zakres","range":"(0,5 – 20,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,5 – 20,0) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganiowy (utlenialność)\nZakres (0,5 – 20,0) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Indeks nadmanganiowy (utlenialność)\nZakres (0,5 – 20,0) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda do spozycia przez ludzi, Woda na plywalniach Indeks nadmanganiowy (utlenialnosc)\nZakres (0,5 – 20,0) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Swimming pool water Permanganate index (oxidisability) Titrimetric method Range PN-EN ISO 8467:2001","parameters_zh":[{"name":"范围","range":"(0,5 – 20,0) mg/l O2"}],"search_zh":"生活饮用水、游泳池水 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"生活饮用水、游泳池水"},{"_id":"6a5e783e4cc76d93cba39ae3","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach, Woda źródlana, Woda mineralna","test_object_en":"Water intended for human consumption, Swimming pool water, Spring water, Mineral water","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(1 – 60,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(1 – 60,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres (1 – 60,00) mg/l\nMetoda spektrofotometryczna","reference":"PBL-33 wyd. I z dnia 01.03.2018 r. na podstawie testu HACH LANGE LCK 339","norm_bases":["PBL-33 wyd. I z dnia 01.03.2018 r. na podstawie testu HACH LANGE LCK 339"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach, Woda źródlana, Woda mineralna Stężenie azotanów\nZakres (1 – 60,00) mg/l\nMetoda spektrofotometryczna PBL-33 wyd. I z dnia 01.03.2018 r. na podstawie testu HACH LANGE LCK 339 Woda do spozycia przez ludzi, Woda na plywalniach, Woda zrodlana, Woda mineralna Stezenie azotanow\nZakres (1 – 60,00) mg/l\nMetoda spektrofotometryczna PBL-33 wyd. I z dnia 01.03.2018 r. na podstawie testu HACH LANGE LCK 339","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Swimming pool water, Spring water, Mineral water Nitrate concentration Spectrophotometric method Range PBL-33 wyd. I z dnia 01.03.2018 r. na podstawie testu HACH LANGE LCK 339","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(1 – 60,00) mg/l"}],"search_zh":"硝酸盐浓度 分光光度法 范围 PBL-33 wyd. I z dnia 01.03.2018 r. na podstawie testu HACH LANGE LCK 339","technique_zh":"分光光度法"},{"_id":"6a5e783e4cc76d93cba39ae4","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna","test_object_en":"Water intended for human consumption, Spring water, Mineral water","methodology":"Stężenie azotynów","methodology_en":"Nitrite concentration","parameters":[{"name":"Zakres","range":"(0,05 – 2,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotynów\nZakres (0,05 – 2,00) mg/l\nMetoda spektrofotometryczna","reference":"PBL-32 wyd. I z dnia 01.03.2018 r. na podstawie testu HACH LANGE nr LCK 341","norm_bases":["PBL-32 wyd. I z dnia 01.03.2018 r. na podstawie testu HACH LANGE nr LCK 341"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna Stężenie azotynów\nZakres (0,05 – 2,00) mg/l\nMetoda spektrofotometryczna PBL-32 wyd. I z dnia 01.03.2018 r. na podstawie testu HACH LANGE nr LCK 341 Woda do spozycia przez ludzi, Woda zrodlana, Woda mineralna Stezenie azotynow\nZakres (0,05 – 2,00) mg/l\nMetoda spektrofotometryczna PBL-32 wyd. I z dnia 01.03.2018 r. na podstawie testu HACH LANGE nr LCK 341","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Spring water, Mineral water Nitrite concentration Spectrophotometric method Range PBL-32 wyd. I z dnia 01.03.2018 r. na podstawie testu HACH LANGE nr LCK 341","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 2,00) mg/l"}],"search_zh":"生活饮用水、泉水、矿泉水 亚硝酸盐浓度 分光光度法 范围 PBL-32 wyd. I z dnia 01.03.2018 r. na podstawie testu HACH LANGE nr LCK 341","technique_zh":"分光光度法","test_object_zh":"生活饮用水、泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39ae5","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna","test_object_en":"Water intended for human consumption, Spring water, Mineral water","methodology":"Stężenie jonu amonowego","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,03 – 3,25) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,03 – 3,25) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego\nZakres (0,03 – 3,25) mg/l\nMetoda spektrofotometryczna","reference":"PBL-03 wyd. IV z dnia 29.01.2018 r. | na podstawie metody HACH LANGE nr 8038","norm_bases":["PBL-03 wyd. IV z dnia 29.01.2018 r.","na podstawie metody HACH LANGE nr 8038"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna Stężenie jonu amonowego\nZakres (0,03 – 3,25) mg/l\nMetoda spektrofotometryczna PBL-03 wyd. IV z dnia 29.01.2018 r. | na podstawie metody HACH LANGE nr 8038 Woda do spozycia przez ludzi, Woda zrodlana, Woda mineralna Stezenie jonu amonowego\nZakres (0,03 – 3,25) mg/l\nMetoda spektrofotometryczna PBL-03 wyd. IV z dnia 29.01.2018 r. | na podstawie metody HACH LANGE nr 8038","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Spring water, Mineral water Ammonium ion concentration Spectrophotometric method Range PBL-03 wyd. IV z dnia 29.01.2018 r. | na podstawie metody HACH LANGE nr 8038","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,03 – 3,25) mg/l"}],"search_zh":"生活饮用水、泉水、矿泉水 铵离子浓度 分光光度法 范围 PBL-03 wyd. IV z dnia 29.01.2018 r. | na podstawie metody HACH LANGE nr 8038","technique_zh":"分光光度法","test_object_zh":"生活饮用水、泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39ae6","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna","test_object_en":"Water intended for human consumption, Spring water, Mineral water","methodology":"Stężenie żelaza","methodology_en":"Iron concentration","parameters":[{"name":"Zakres","range":"(20 – 3000) μg/l"}],"parameters_en":[{"name":"Range","range":"(20 – 3000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza\nZakres (20 – 3000) μg/l\nMetoda spektrofotometryczna","reference":"PBL-05 wyd. IV z dnia 29.01.2018 r. | na podstawie metody HACH LANGE nr 8008","norm_bases":["PBL-05 wyd. IV z dnia 29.01.2018 r.","na podstawie metody HACH LANGE nr 8008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna Stężenie żelaza\nZakres (20 – 3000) μg/l\nMetoda spektrofotometryczna PBL-05 wyd. IV z dnia 29.01.2018 r. | na podstawie metody HACH LANGE nr 8008 Woda do spozycia przez ludzi, Woda zrodlana, Woda mineralna Stezenie zelaza\nZakres (20 – 3000) μg/l\nMetoda spektrofotometryczna PBL-05 wyd. IV z dnia 29.01.2018 r. | na podstawie metody HACH LANGE nr 8008","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Spring water, Mineral water Iron concentration Spectrophotometric method Range PBL-05 wyd. IV z dnia 29.01.2018 r. | na podstawie metody HACH LANGE nr 8008","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(20 – 3000) μg/l"}],"search_zh":"生活饮用水、泉水、矿泉水 铁浓度 分光光度法 范围 PBL-05 wyd. IV z dnia 29.01.2018 r. | na podstawie metody HACH LANGE nr 8008","technique_zh":"分光光度法","test_object_zh":"生活饮用水、泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39ae7","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna","test_object_en":"Water intended for human consumption, Spring water, Mineral water","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(6 – 700) μg/l"}],"parameters_en":[{"name":"Range","range":"(6 – 700) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (6 – 700) μg/l\nMetoda spektrofotometryczna","reference":"PBL-04 wyd. IV z dnia 29.01.2018 r. | na podstawie metody HACH LANGE nr 8149","norm_bases":["PBL-04 wyd. IV z dnia 29.01.2018 r.","na podstawie metody HACH LANGE nr 8149"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna Stężenie manganu\nZakres (6 – 700) μg/l\nMetoda spektrofotometryczna PBL-04 wyd. IV z dnia 29.01.2018 r. | na podstawie metody HACH LANGE nr 8149 Woda do spozycia przez ludzi, Woda zrodlana, Woda mineralna Stezenie manganu\nZakres (6 – 700) μg/l\nMetoda spektrofotometryczna PBL-04 wyd. IV z dnia 29.01.2018 r. | na podstawie metody HACH LANGE nr 8149","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Spring water, Mineral water Manganese concentration Spectrophotometric method Range PBL-04 wyd. IV z dnia 29.01.2018 r. | na podstawie metody HACH LANGE nr 8149","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(6 – 700) μg/l"}],"search_zh":"生活饮用水、泉水、矿泉水 锰浓度 分光光度法 范围 PBL-04 wyd. IV z dnia 29.01.2018 r. | na podstawie metody HACH LANGE nr 8149","technique_zh":"分光光度法","test_object_zh":"生活饮用水、泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39ae8","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna","test_object_en":"Water intended for human consumption, Spring water, Mineral water","methodology":"Twardość ogólna (sumaryczna zawartość wapnia i magnezu)","methodology_en":"Total hardness (total content of calcium and magnesium)","parameters":[{"name":"Zakres","range":"(5 – 1000) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(5 – 1000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Twardość ogólna (sumaryczna zawartość wapnia i magnezu)\nZakres (5 – 1000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna Twardość ogólna (sumaryczna zawartość wapnia i magnezu)\nZakres (5 – 1000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi, Woda zrodlana, Woda mineralna Twardosc ogolna (sumaryczna zawartosc wapnia i magnezu)\nZakres (5 – 1000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Spring water, Mineral water Total hardness (total content of calcium and magnesium) Titrimetric method Range PN-ISO 6059:1999","parameters_zh":[{"name":"范围","range":"(5 – 1000) mg/l CaCO3"}],"search_zh":"生活饮用水、泉水、矿泉水 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"生活饮用水、泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39ae9","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna","test_object_en":"Water intended for human consumption, Spring water, Mineral water","methodology":"Stężenie wapnia","methodology_en":"Calcium concentration","parameters":[{"name":"Zakres","range":"(2 – 400) mg/l"}],"parameters_en":[{"name":"Range","range":"(2 – 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie wapnia\nZakres (2 – 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna Stężenie wapnia\nZakres (2 – 400) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda do spozycia przez ludzi, Woda zrodlana, Woda mineralna Stezenie wapnia\nZakres (2 – 400) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Spring water, Mineral water Calcium concentration Titrimetric method Range PN-ISO 6058:1999","parameters_zh":[{"name":"范围","range":"(2 – 400) mg/l"}],"search_zh":"生活饮用水、泉水、矿泉水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","methodology_zh":"钙浓度","test_object_zh":"生活饮用水、泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39aea","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna","test_object_en":"Water intended for human consumption, Spring water, Mineral water","methodology":"Stężenie magnezu (z obliczeń)","methodology_en":"Magnesium concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C-04554-4:1999","norm_bases":["PN-C-04554-4:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna Stężenie magnezu (z obliczeń) PN-C-04554-4:1999 Woda do spozycia przez ludzi, Woda zrodlana, Woda mineralna Stezenie magnezu (z obliczen) PN-C-04554-4:1999","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Spring water, Mineral water Magnesium concentration (calculated) PN-C-04554-4:1999","methodology_zh":"镁浓度（计算值）","search_zh":"生活饮用水、泉水、矿泉水 镁浓度（计算值） PN-C-04554-4:1999","test_object_zh":"生活饮用水、泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39aeb","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna","test_object_en":"Water intended for human consumption, Spring water, Mineral water","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5 – 300)mg/l"}],"parameters_en":[{"name":"Range","range":"(5 – 300)mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5 – 300)mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna Stężenie chlorków\nZakres (5 – 300)mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda do spozycia przez ludzi, Woda zrodlana, Woda mineralna Stezenie chlorkow\nZakres (5 – 300)mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Spring water, Mineral water Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 – 300)mg/l"}],"search_zh":"生活饮用水、泉水、矿泉水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"生活饮用水、泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39aec","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna","test_object_en":"Water intended for human consumption, Spring water, Mineral water","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,00 – 10,00"}],"parameters_en":[{"name":"Range","range":"4,00 – 10,00"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,00 – 10,00\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna pH\nZakres 4,00 – 10,00\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi, Woda zrodlana, Woda mineralna pH\nZakres 4,00 – 10,00\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Spring water, Mineral water pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,00 – 10,00"}],"search_zh":"生活饮用水、泉水、矿泉水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水、泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39aed","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna","test_object_en":"Water intended for human consumption, Spring water, Mineral water","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(10 – 3000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(10 – 3000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 3000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna Przewodność elektryczna właściwa\nZakres (10 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi, Woda zrodlana, Woda mineralna Przewodnosc elektryczna wlasciwa\nZakres (10 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Spring water, Mineral water Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 3000) μS/cm"}],"search_zh":"生活饮用水、泉水、矿泉水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水、泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39aee","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna","test_object_en":"Water intended for human consumption, Spring water, Mineral water","methodology":"Stężenie potasu","methodology_en":"Potassium concentration","parameters":[{"name":"Zakres","range":"(0,1 – 7,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,1 – 7,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie potasu\nZakres (0,1 – 7,0) mg/l\nMetoda spektrofotometryczna","reference":"PBL-08 wyd. IV z dnia 29.01.2018r. | na podstawie metody HACH LANGE nr 8049","norm_bases":["PBL-08 wyd. IV z dnia 29.01.2018r.","na podstawie metody HACH LANGE nr 8049"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna Stężenie potasu\nZakres (0,1 – 7,0) mg/l\nMetoda spektrofotometryczna PBL-08 wyd. IV z dnia 29.01.2018r. | na podstawie metody HACH LANGE nr 8049 Woda do spozycia przez ludzi, Woda zrodlana, Woda mineralna Stezenie potasu\nZakres (0,1 – 7,0) mg/l\nMetoda spektrofotometryczna PBL-08 wyd. IV z dnia 29.01.2018r. | na podstawie metody HACH LANGE nr 8049","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Spring water, Mineral water Potassium concentration Spectrophotometric method Range PBL-08 wyd. IV z dnia 29.01.2018r. | na podstawie metody HACH LANGE nr 8049","parameters_zh":[{"name":"范围","range":"(0,1 – 7,0) mg/l"}],"search_zh":"生活饮用水、泉水、矿泉水 钾浓度 分光光度法 范围 PBL-08 wyd. IV z dnia 29.01.2018r. | na podstawie metody HACH LANGE nr 8049","technique_zh":"分光光度法","methodology_zh":"钾浓度","test_object_zh":"生活饮用水、泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39aef","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna","test_object_en":"Water intended for human consumption, Spring water, Mineral water","methodology":"Stężenie sodu","methodology_en":"Sodium concentration","parameters":[{"name":"Zakres","range":"(10 – 400) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 400) mg/l"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"Stężenie sodu\nZakres (10 – 400) mg/l\nMetoda potencjometryczna","reference":"PBL-09 wyd. IV z dnia 29.01.2018r na podstawie metody HACH LANGE nr 4451569","norm_bases":["PBL-09 wyd. IV z dnia 29.01.2018r na podstawie metody HACH LANGE nr 4451569"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna Stężenie sodu\nZakres (10 – 400) mg/l\nMetoda potencjometryczna PBL-09 wyd. IV z dnia 29.01.2018r na podstawie metody HACH LANGE nr 4451569 Woda do spozycia przez ludzi, Woda zrodlana, Woda mineralna Stezenie sodu\nZakres (10 – 400) mg/l\nMetoda potencjometryczna PBL-09 wyd. IV z dnia 29.01.2018r na podstawie metody HACH LANGE nr 4451569","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Spring water, Mineral water Sodium concentration Potentiometric method Range PBL-09 wyd. IV z dnia 29.01.2018r na podstawie metody HACH LANGE nr 4451569","parameters_zh":[{"name":"范围","range":"(10 – 400) mg/l"}],"search_zh":"生活饮用水、泉水、矿泉水 钠浓度 电位法 范围 PBL-09 wyd. IV z dnia 29.01.2018r na podstawie metody HACH LANGE nr 4451569","technique_zh":"电位法","methodology_zh":"钠浓度","test_object_zh":"生活饮用水、泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39af0","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna","test_object_en":"Water intended for human consumption, Spring water, Mineral water","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(2 – 250) mg/l"}],"parameters_en":[{"name":"Range","range":"(2 – 250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (2 – 250) mg/l\nMetoda spektrofotometryczna","reference":"PBL-06 wyd. IV z dnia 29.01.2018r. | na podstawie metody HACH LANGE nr 8051","norm_bases":["PBL-06 wyd. IV z dnia 29.01.2018r.","na podstawie metody HACH LANGE nr 8051"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna Stężenie siarczanów\nZakres (2 – 250) mg/l\nMetoda spektrofotometryczna PBL-06 wyd. IV z dnia 29.01.2018r. | na podstawie metody HACH LANGE nr 8051 Woda do spozycia przez ludzi, Woda zrodlana, Woda mineralna Stezenie siarczanow\nZakres (2 – 250) mg/l\nMetoda spektrofotometryczna PBL-06 wyd. IV z dnia 29.01.2018r. | na podstawie metody HACH LANGE nr 8051","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Spring water, Mineral water Sulfate concentration Spectrophotometric method Range PBL-06 wyd. IV z dnia 29.01.2018r. | na podstawie metody HACH LANGE nr 8051","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(2 – 250) mg/l"}],"search_zh":"生活饮用水、泉水、矿泉水 硫酸盐浓度 分光光度法 范围 PBL-06 wyd. IV z dnia 29.01.2018r. | na podstawie metody HACH LANGE nr 8051","technique_zh":"分光光度法","test_object_zh":"生活饮用水、泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39af1","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna","test_object_en":"Water intended for human consumption, Spring water, Mineral water","methodology":"Zasadowość ogólna","methodology_en":"Total alkalinity","parameters":[{"name":"Zakres","range":"(0,40 – 100) mmol/l"},{"name":"Zasadowość mineralna"},{"name":"Zakres","range":"(0,40 – 100) mmol/l"}],"parameters_en":[{"name":"Range","range":"(0,40 – 100) mmol/l"},{"name":"Mineral alkalinity"},{"name":"Range","range":"(0,40 – 100) mmol/l"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"technique_en":"Potentiometric titration method","computed":[],"computed_en":[],"activity":"Zasadowość ogólna\nZakres:\nZakres (0,40 – 100) mmol/l\nZasadowość mineralna\nZakres (0,40 – 100) mmol/l\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN ISO 9963-1:2001 pkt 8.1 | PN-EN ISO 9963-1:2001/Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001 pkt 8.1","PN-EN ISO 9963-1:2001/Ap1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna Zasadowość ogólna\nZakres:\nZakres (0,40 – 100) mmol/l\nZasadowość mineralna\nZakres (0,40 – 100) mmol/l\nMetoda miareczkowania potencjometrycznego PN-EN ISO 9963-1:2001 pkt 8.1 | PN-EN ISO 9963-1:2001/Ap1:2004 Woda do spozycia przez ludzi, Woda zrodlana, Woda mineralna Zasadowosc ogolna\nZakres:\nZakres (0,40 – 100) mmol/l\nZasadowosc mineralna\nZakres (0,40 – 100) mmol/l\nMetoda miareczkowania potencjometrycznego PN-EN ISO 9963-1:2001 pkt 8.1 | PN-EN ISO 9963-1:2001/Ap1:2004","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Spring water, Mineral water Total alkalinity Potentiometric titration method Range Mineral alkalinity Range PN-EN ISO 9963-1:2001 pkt 8.1 | PN-EN ISO 9963-1:2001/Ap1:2004","parameters_zh":[{"name":"范围","range":"(0,40 – 100) mmol/l"},{"name":"矿物碱度"},{"name":"范围","range":"(0,40 – 100) mmol/l"}],"search_zh":"生活饮用水、泉水、矿泉水 总碱度 电位滴定法 范围 矿物碱度 范围 PN-EN ISO 9963-1:2001 pkt 8.1 | PN-EN ISO 9963-1:2001/Ap1:2004","technique_zh":"电位滴定法","methodology_zh":"总碱度","test_object_zh":"生活饮用水、泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39af2","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna","test_object_en":"Water intended for human consumption, Spring water, Mineral water","methodology":"Stężenie kwaśnych węglanów (wodorowęglanów) (z obliczeń)","methodology_en":"Concentration of acid carbonates (hydrogen carbonates) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie kwaśnych węglanów (wodorowęglanów) (z obliczeń)","reference":"PN-EN ISO 9963-1:2001 pkt 8.1 | PN-EN ISO 9963-1:2001/Ap1:2004 załącznik A","norm_bases":["PN-EN ISO 9963-1:2001 pkt 8.1","PN-EN ISO 9963-1:2001/Ap1:2004 załącznik A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna Stężenie kwaśnych węglanów (wodorowęglanów) (z obliczeń) PN-EN ISO 9963-1:2001 pkt 8.1 | PN-EN ISO 9963-1:2001/Ap1:2004 załącznik A Woda do spozycia przez ludzi, Woda zrodlana, Woda mineralna Stezenie kwasnych weglanow (wodoroweglanow) (z obliczen) PN-EN ISO 9963-1:2001 pkt 8.1 | PN-EN ISO 9963-1:2001/Ap1:2004 zalacznik A","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Spring water, Mineral water Concentration of acid carbonates (hydrogen carbonates) (calculated) PN-EN ISO 9963-1:2001 pkt 8.1 | PN-EN ISO 9963-1:2001/Ap1:2004 załącznik A","search_zh":"生活饮用水、泉水、矿泉水 PN-EN ISO 9963-1:2001 pkt 8.1 | PN-EN ISO 9963-1:2001/Ap1:2004 załącznik A","test_object_zh":"生活饮用水、泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39af3","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna","test_object_en":"Water intended for human consumption, Spring water, Mineral water","methodology":"Stężenie baru","methodology_en":"Barium concentration","parameters":[{"name":"Zakres","range":"(0,06 - 10) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,06 - 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie baru\nZakres (0,06 - 10) mg/l\nMetoda spektrofotometryczna","reference":"PBL-45 wyd. II z dnia 29.03.2023 na podstawie metody HACH LANGE nr 8014","norm_bases":["PBL-45 wyd. II z dnia 29.03.2023 na podstawie metody HACH LANGE nr 8014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna Stężenie baru\nZakres (0,06 - 10) mg/l\nMetoda spektrofotometryczna PBL-45 wyd. II z dnia 29.03.2023 na podstawie metody HACH LANGE nr 8014 Woda do spozycia przez ludzi, Woda zrodlana, Woda mineralna Stezenie baru\nZakres (0,06 - 10) mg/l\nMetoda spektrofotometryczna PBL-45 wyd. II z dnia 29.03.2023 na podstawie metody HACH LANGE nr 8014","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Spring water, Mineral water Barium concentration Spectrophotometric method Range PBL-45 wyd. II z dnia 29.03.2023 na podstawie metody HACH LANGE nr 8014","parameters_zh":[{"name":"范围","range":"(0,06 - 10) mg/l"}],"search_zh":"生活饮用水、泉水、矿泉水 分光光度法 范围 PBL-45 wyd. II z dnia 29.03.2023 na podstawie metody HACH LANGE nr 8014","technique_zh":"分光光度法","test_object_zh":"生活饮用水、泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39af4","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna","test_object_en":"Water intended for human consumption, Spring water, Mineral water","methodology":"Stężenie fluorków","methodology_en":"Fluoride concentration","parameters":[{"name":"Zakres","range":"(0,02 - 2,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,02 - 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fluorków\nZakres (0,02 - 2,00) mg/l\nMetoda spektrofotometryczna","reference":"PBL-44 wyd. II z dnia 29.03.2023r na podstawie metody HACH LANGE nr 8029","norm_bases":["PBL-44 wyd. II z dnia 29.03.2023r na podstawie metody HACH LANGE nr 8029"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna Stężenie fluorków\nZakres (0,02 - 2,00) mg/l\nMetoda spektrofotometryczna PBL-44 wyd. II z dnia 29.03.2023r na podstawie metody HACH LANGE nr 8029 Woda do spozycia przez ludzi, Woda zrodlana, Woda mineralna Stezenie fluorkow\nZakres (0,02 - 2,00) mg/l\nMetoda spektrofotometryczna PBL-44 wyd. II z dnia 29.03.2023r na podstawie metody HACH LANGE nr 8029","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Spring water, Mineral water Fluoride concentration Spectrophotometric method Range PBL-44 wyd. II z dnia 29.03.2023r na podstawie metody HACH LANGE nr 8029","parameters_zh":[{"name":"范围","range":"(0,02 - 2,00) mg/l"}],"search_zh":"生活饮用水、泉水、矿泉水 氟化物浓度 分光光度法 范围 PBL-44 wyd. II z dnia 29.03.2023r na podstawie metody HACH LANGE nr 8029","technique_zh":"分光光度法","methodology_zh":"氟化物浓度","test_object_zh":"生活饮用水、泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39af5","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna","test_object_en":"Water intended for human consumption, Spring water, Mineral water","methodology":"Suma składników mineralnych (Mineralizacja ogólna) z obliczeń","methodology_en":"Sum of mineral components (total mineralisation) calculated","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma składników mineralnych (Mineralizacja ogólna) z obliczeń","reference":"PBL-43 wyd. II z dnia 29.03.2023 r.","norm_bases":["PBL-43 wyd. II z dnia 29.03.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda źródlana, Woda mineralna Suma składników mineralnych (Mineralizacja ogólna) z obliczeń PBL-43 wyd. II z dnia 29.03.2023 r. Woda do spozycia przez ludzi, Woda zrodlana, Woda mineralna Suma skladnikow mineralnych (Mineralizacja ogolna) z obliczen PBL-43 wyd. II z dnia 29.03.2023 r.","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Spring water, Mineral water Sum of mineral components (total mineralisation) calculated PBL-43 wyd. II z dnia 29.03.2023 r.","search_zh":"生活饮用水、泉水、矿泉水 PBL-43 wyd. II z dnia 29.03.2023 r.","test_object_zh":"生活饮用水、泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39af6","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda źródlana, Woda mineralna","test_object_en":"Spring water, Mineral water","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12 /A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda źródlana, Woda mineralna Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04 Woda zrodlana, Woda mineralna Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","categories":["water","microbiology"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Spring water, Mineral water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"泉水、矿泉水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39af7","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda źródlana, Woda mineralna","test_object_en":"Spring water, Mineral water","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PBL-39 wyd. I z dn. 15.07.2020 r.","norm_bases":["PBL-39 wyd. I z dn. 15.07.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda źródlana, Woda mineralna Liczba Escherichia coli\nMetoda filtracji membranowej PBL-39 wyd. I z dn. 15.07.2020 r. Woda zrodlana, Woda mineralna Liczba Escherichia coli\nMetoda filtracji membranowej PBL-39 wyd. I z dn. 15.07.2020 r.","categories":["water","microbiology"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Spring water, Mineral water Escherichia coli count Membrane filtration method PBL-39 wyd. I z dn. 15.07.2020 r.","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"泉水、矿泉水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PBL-39 wyd. I z dn. 15.07.2020 r.","technique_zh":"膜过滤法","test_object_zh":"泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39af8","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda źródlana, Woda mineralna","test_object_en":"Spring water, Mineral water","methodology":"Liczba enterokoków kałowych","methodology_en":"Intestinal enterococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda źródlana, Woda mineralna Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda zrodlana, Woda mineralna Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Spring water, Mineral water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","methodology_zh":"粪肠球菌计数","search_zh":"泉水、矿泉水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39af9","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda źródlana, Woda mineralna","test_object_en":"Spring water, Mineral water","methodology":"Liczba Pseudomonas aerugionosa","methodology_en":"Count of Pseudomonas aerugionosa","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aerugionosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda źródlana, Woda mineralna Liczba Pseudomonas aerugionosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda zrodlana, Woda mineralna Liczba Pseudomonas aerugionosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Spring water, Mineral water Count of Pseudomonas aerugionosa Membrane filtration method PN-EN ISO 16266:2009","search_zh":"泉水、矿泉水 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39afa","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda źródlana, Woda mineralna","test_object_en":"Spring water, Mineral water","methodology":"Ogólna liczba mikroorganizmów w 37 °C","methodology_en":"Total count of microorganisms at 37 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 37 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PBL-37 wyd. I z dn. 12.07.2018 r.","norm_bases":["PBL-37 wyd. I z dn. 12.07.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda źródlana, Woda mineralna Ogólna liczba mikroorganizmów w 37 °C\nMetoda płytkowa (posiew wgłębny) PBL-37 wyd. I z dn. 12.07.2018 r. Woda zrodlana, Woda mineralna Ogolna liczba mikroorganizmow w 37 °C\nMetoda plytkowa (posiew wglebny) PBL-37 wyd. I z dn. 12.07.2018 r.","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Spring water, Mineral water Total count of microorganisms at 37 °C Plate method (pour plate) PBL-37 wyd. I z dn. 12.07.2018 r.","search_zh":"泉水、矿泉水 平板法（倾注培养） PBL-37 wyd. I z dn. 12.07.2018 r.","technique_zh":"平板法（倾注培养）","test_object_zh":"泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39afb","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda źródlana, Woda mineralna","test_object_en":"Spring water, Mineral water","methodology":"Ogólna liczba mikroorganizmów w 22 °C","methodology_en":"Total viable count at 22 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PBL-37 wyd. I z dn. 12.07.2018 r.","norm_bases":["PBL-37 wyd. I z dn. 12.07.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda źródlana, Woda mineralna Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny) PBL-37 wyd. I z dn. 12.07.2018 r. Woda zrodlana, Woda mineralna Ogolna liczba mikroorganizmow w 22 °C\nMetoda plytkowa (posiew wglebny) PBL-37 wyd. I z dn. 12.07.2018 r.","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Spring water, Mineral water Total viable count at 22 °C Plate method (pour plate) PBL-37 wyd. I z dn. 12.07.2018 r.","methodology_zh":"22 °C 微生物总数","search_zh":"泉水、矿泉水 22 °C 微生物总数 平板法（倾注培养） PBL-37 wyd. I z dn. 12.07.2018 r.","technique_zh":"平板法（倾注培养）","test_object_zh":"泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39afc","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda źródlana, Woda mineralna","test_object_en":"Spring water, Mineral water","methodology":"Liczba przetrwalników beztlenowców redukujących siarczyny (Clostridia)","methodology_en":"Count of spores of sulphite-reducing anaerobes (Clostridia)","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba przetrwalników beztlenowców redukujących siarczyny (Clostridia)\nMetoda filtracji membranowej","reference":"PN-EN 26461-2:2001","norm_bases":["PN-EN 26461-2:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda źródlana, Woda mineralna Liczba przetrwalników beztlenowców redukujących siarczyny (Clostridia)\nMetoda filtracji membranowej PN-EN 26461-2:2001 Woda zrodlana, Woda mineralna Liczba przetrwalnikow beztlenowcow redukujacych siarczyny (Clostridia)\nMetoda filtracji membranowej PN-EN 26461-2:2001","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Spring water, Mineral water Count of spores of sulphite-reducing anaerobes (Clostridia) Membrane filtration method PN-EN 26461-2:2001","search_zh":"泉水、矿泉水 亚硫酸盐还原厌氧菌（梭菌属）芽孢数 膜过滤法 PN-EN 26461-2:2001","technique_zh":"膜过滤法","methodology_zh":"亚硫酸盐还原厌氧菌（梭菌属）芽孢数","test_object_zh":"泉水、矿泉水"},{"_id":"6a5e783e4cc76d93cba39afd","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba Gronkowców koagulazododatnich","methodology_en":"Coagulase-positive Staphylococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Gronkowców koagulazododatnich\nMetoda filtracji membranowej","reference":"PZH ZHK:2007","norm_bases":["PZH ZHK:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba Gronkowców koagulazododatnich\nMetoda filtracji membranowej PZH ZHK:2007 Woda na plywalniach Liczba Gronkowcow koagulazododatnich\nMetoda filtracji membranowej PZH ZHK:2007","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Coagulase-positive Staphylococci count Membrane filtration method PZH ZHK:2007","search_zh":"游泳池水 凝固酶阳性葡萄球菌数 膜过滤法 PZH ZHK:2007","technique_zh":"膜过滤法","test_object_zh":"游泳池水","methodology_zh":"凝固酶阳性葡萄球菌数"},{"_id":"6a5e783e4cc76d93cba39afe","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/ A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","categories":["water","microbiology"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a5e783e4cc76d93cba39aff","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba enterokoków kałowych","methodology_en":"Intestinal enterococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","methodology_zh":"粪肠球菌计数","search_zh":"生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a5e783e4cc76d93cba39b00","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 22 °C","methodology_en":"Total viable count at 22 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004","methodology_zh":"22 °C 微生物总数","search_zh":"生活饮用水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水"},{"_id":"6a5e783e4cc76d93cba39b01","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","test_object_en":"Water intended for human consumption, Swimming pool water","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12 /A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04 Woda do spozycia przez ludzi, Woda na plywalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","categories":["water","microbiology"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水、游泳池水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水、游泳池水"},{"_id":"6a5e783e4cc76d93cba39b02","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","test_object_en":"Water intended for human consumption, Swimming pool water","methodology":"Liczba Pseudomonas aerugionosa","methodology_en":"Count of Pseudomonas aerugionosa","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aerugionosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Liczba Pseudomonas aerugionosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda do spozycia przez ludzi, Woda na plywalniach Liczba Pseudomonas aerugionosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Swimming pool water Count of Pseudomonas aerugionosa Membrane filtration method PN-EN ISO 16266:2009","search_zh":"生活饮用水、游泳池水 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"生活饮用水、游泳池水"},{"_id":"6a5e783e4cc76d93cba39b03","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","test_object_en":"Water intended for human consumption, Swimming pool water","methodology":"Ogólna liczba mikroorganizmów w 36 °C","methodology_en":"Total viable count at 36 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi, Woda na plywalniach Ogolna liczba mikroorganizmow w 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Swimming pool water Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","methodology_zh":"36 °C 微生物总数","search_zh":"生活饮用水、游泳池水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水、游泳池水"},{"_id":"6a5e783e4cc76d93cba39b04","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","test_object_en":"Water intended for human consumption, Swimming pool water","methodology":"Liczba bakterii Legionella sp. Matryca A: Procedura 5 (pożywka A), Procedura 7 (pożywka C-GVPC)","methodology_en":"Legionella sp. count Matrix A: Procedure 5 (medium A), Procedure 7 (C-GVPC medium)","parameters":[{"name":"Zakres","range":"od 1 jtk/100 ml"}],"parameters_en":[{"name":"Range","range":"od 1 jtk/100 ml"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii Legionella sp. Matryca A: Procedura 5 (pożywka A), Procedura 7 (pożywka C-GVPC)\nZakres od 1 jtk/100 ml\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08","PN-EN ISO 11731:2017-08 /Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Liczba bakterii Legionella sp. Matryca A: Procedura 5 (pożywka A), Procedura 7 (pożywka C-GVPC)\nZakres od 1 jtk/100 ml\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12 Woda do spozycia przez ludzi, Woda na plywalniach Liczba bakterii Legionella sp. Matryca A: Procedura 5 (pozywka A), Procedura 7 (pozywka C-GVPC)\nZakres od 1 jtk/100 ml\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","categories":["microbiology","water"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Swimming pool water Legionella sp. count Matrix A: Procedure 5 (medium A), Procedure 7 (C-GVPC medium) Membrane filtration method Range PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","parameters_zh":[{"name":"范围","range":"od 1 jtk/100 ml"}],"search_zh":"生活饮用水、游泳池水 膜过滤法 范围 PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"生活饮用水、游泳池水"},{"_id":"6a5e783e4cc76d93cba39b05","lab_id":"69ad52a3de79e566650fb911","country":"PL","accr_number":"AB 1719","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","test_object_en":"Water intended for human consumption, Swimming pool water","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi, Woda na plywalniach Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, Swimming pool water Sampling for microbiological testing PN-EN ISO 19458:2007","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水、游泳池水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水、游泳池水"}],"has_pdf":true}