{"lab":{"_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","address":"PAŃSTWOWY INSTYTUT BADAWCZY, Pl. Gwarków 1, 40-166 Katowice, JEDNOSTKA OCENY ZGODNOŚCI, ul. Podleska 72, 43-190 Mikołów","categories":["materials"],"city":"Mikołów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":101,"name":"GŁÓWNY INSTYTUT GÓRNICTWA –","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1710.pdf"],"scope_summary":"","search_text":"główny instytut górnictwa – państwowy instytut badawczy, pl. gwarków 1, 40-166 katowice, jednostka oceny zgodności, ul. podleska 72, 43-190 mikołów materials other pharma electronics metrology construction water food","status":"active","updated_at":"2026-03-08T14:50:50.396Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:50.396Z","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%201710,podmiot.html","fields_of_testing":[{"codes":"E/6; E/8; E/13; E/17; E/19; E/21; E/23","pl":"Badania elektryczne i elektroniczne wyrobów i wyposażenia elektrycznego, wyrobów i materiałów konstrukcyjnych, maszyn i urządzeń, wyrobów innych, środków ochrony osobistej, wyrobów z tworzyw sztucznych i gumy, tekstyliów i skóry","en":"Electric and electronic tests of electrical products and equipment, construction products and materials, machinery and devices, other products, personal protection equipment, plastic and rubber products, textiles and leather"},{"codes":"H/6; H/8; H/19","pl":"Badania ogniowe wyrobów i wyposażenia elektrycznego, wyrobów i materiałów konstrukcyjnych, środków ochrony osobistej","en":"Fire tests of electrical products and equipment, construction products and materials, personal protection equipment"},{"codes":"J/6; J/8; J/13; J/17; J/21","pl":"Badania mechaniczne wyrobów i wyposażenia elektrycznego, wyrobów i materiałów konstrukcyjnych, maszyn i urządzeń, wyrobów innych, wyrobów z tworzyw sztucznych i gumy","en":"Mechanical tests of electrical products and equipment, construction products and materials, machinery and devices, other products, plastic and rubber products"},{"codes":"N/6; N/8; N/17; N/21; N/23; N/52","pl":"Badania właściwości fizycznych wyrobów i wyposażenia elektrycznego, wyrobów i materiałów konstrukcyjnych, wyrobów innych, wyrobów z tworzyw sztucznych i gumy, tekstyliów i skóry, materiałów wybuchowych i amunicji","en":"Tests of physical properties of electrical products and equipment, construction products and materials, other products, plastic and rubber products, textiles and leather, explosives and ammunition"}],"issue":{"no":"5","date":"05.09.2023"},"parse_date":"2026-07-20T07:09:27.955Z","parse_source":"script-pdfplumber","map_coord":[50.179698,18.931741],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":74,"materials":22,"water":2,"construction":2,"petro":1},"category_scores":{"other":54.22,"materials":4.79,"water":0.04,"construction":0.04,"petro":0.01},"has_zh":true},"methods":[{"_id":"6a5dc9a7f1c10c8ce8259ad0","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Materiały wybuchowe","test_object_en":"Explosives","methodology":"Średnica, masa i gęstość naboi","methodology_en":"Diameter, mass and density of cartridges","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Średnica, masa i gęstość naboi","reference":"JOZ-W.1/L/PB-MW.01 edycja 2 z 08.2023 r.","norm_bases":["JOZ-W.1/L/PB-MW.01 edycja 2 z 08.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały wybuchowe Średnica, masa i gęstość naboi JOZ-W.1/L/PB-MW.01 edycja 2 z 08.2023 r. Materialy wybuchowe Srednica, masa i gestosc naboi JOZ-W.1/L/PB-MW.01 edycja 2 z 08.2023 r.","categories":["materials"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosives Diameter, mass and density of cartridges JOZ-W.1/L/PB-MW.01 edycja 2 z 08.2023 r.","search_zh":"爆炸物 JOZ-W.1/L/PB-MW.01 edycja 2 z 08.2023 r.","test_object_zh":"爆炸物"},{"_id":"6a5dc9a7f1c10c8ce8259ad1","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Materiały wybuchowe","test_object_en":"Explosives","methodology":"Wrażliwość na inicjowanie","methodology_en":"Sensitivity to initiation","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wrażliwość na inicjowanie","reference":"PN-EN 13631-10:2005 JOZ-W.1/L/PB-MW.02 edycja 2 z 08.2023 r.","norm_bases":["PN-EN 13631-10:2005 JOZ-W.1/L/PB-MW.02 edycja 2 z 08.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały wybuchowe Wrażliwość na inicjowanie PN-EN 13631-10:2005 JOZ-W.1/L/PB-MW.02 edycja 2 z 08.2023 r. Materialy wybuchowe Wrazliwosc na inicjowanie PN-EN 13631-10:2005 JOZ-W.1/L/PB-MW.02 edycja 2 z 08.2023 r.","categories":["materials"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosives Sensitivity to initiation PN-EN 13631-10:2005 JOZ-W.1/L/PB-MW.02 edycja 2 z 08.2023 r.","search_zh":"爆炸物 PN-EN 13631-10:2005 JOZ-W.1/L/PB-MW.02 edycja 2 z 08.2023 r.","test_object_zh":"爆炸物"},{"_id":"6a5dc9a7f1c10c8ce8259ad2","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Materiały wybuchowe","test_object_en":"Explosives","methodology":"Badanie przenoszenia detonacji materiałów wybuchowych","methodology_en":"Testing of detonation transmission of explosives","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Badanie przenoszenia detonacji materiałów wybuchowych","reference":"PN-EN 13631-11:2005","norm_bases":["PN-EN 13631-11:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały wybuchowe Badanie przenoszenia detonacji materiałów wybuchowych PN-EN 13631-11:2005 Materialy wybuchowe Badanie przenoszenia detonacji materialow wybuchowych PN-EN 13631-11:2005","categories":["materials"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosives Testing of detonation transmission of explosives PN-EN 13631-11:2005","search_zh":"爆炸物 PN-EN 13631-11:2005","test_object_zh":"爆炸物"},{"_id":"6a5dc9a7f1c10c8ce8259ad3","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Materiały wybuchowe","test_object_en":"Explosives","methodology":"Prędkość detonacji materiałów wybuchowych","methodology_en":"Detonation velocity of explosives","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Prędkość detonacji materiałów wybuchowych","reference":"PN-EN 13631-14:2005","norm_bases":["PN-EN 13631-14:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały wybuchowe Prędkość detonacji materiałów wybuchowych PN-EN 13631-14:2005 Materialy wybuchowe Predkosc detonacji materialow wybuchowych PN-EN 13631-14:2005","categories":["materials"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosives Detonation velocity of explosives PN-EN 13631-14:2005","search_zh":"爆炸物 PN-EN 13631-14:2005","test_object_zh":"爆炸物"},{"_id":"6a5dc9a7f1c10c8ce8259ad4","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Materiały wybuchowe","test_object_en":"Explosives","methodology":"Względna zdolność materiałów wybuchowych do wykonania pracy za pomocą wahadła balistycznego","methodology_en":"Relative capacity of explosives to perform work by means of a ballistic pendulum","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Względna zdolność materiałów wybuchowych do wykonania pracy za pomocą wahadła balistycznego","reference":"PN-C-86035:2022-04","norm_bases":["PN-C-86035:2022-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały wybuchowe Względna zdolność materiałów wybuchowych do wykonania pracy za pomocą wahadła balistycznego PN-C-86035:2022-04 Materialy wybuchowe Wzgledna zdolnosc materialow wybuchowych do wykonania pracy za pomoca wahadla balistycznego PN-C-86035:2022-04","categories":["materials"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosives Relative capacity of explosives to perform work by means of a ballistic pendulum PN-C-86035:2022-04","search_zh":"爆炸物 PN-C-86035:2022-04","test_object_zh":"爆炸物"},{"_id":"6a5dc9a7f1c10c8ce8259ad5","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Materiały wybuchowe","test_object_en":"Explosives","methodology":"Średnica krytyczna materiałów wybuchowych","methodology_en":"Critical diameter of explosives","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Średnica krytyczna materiałów wybuchowych","reference":"PN-C-86028:2000 z wyjątkiem pkt. 2.2f, 2.2g, 2.4","norm_bases":["PN-C-86028:2000 z wyjątkiem pkt. 2.2f, 2.2g, 2.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały wybuchowe Średnica krytyczna materiałów wybuchowych PN-C-86028:2000 z wyjątkiem pkt. 2.2f, 2.2g, 2.4 Materialy wybuchowe Srednica krytyczna materialow wybuchowych PN-C-86028:2000 z wyjatkiem pkt. 2.2f, 2.2g, 2.4","categories":["materials"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosives Critical diameter of explosives PN-C-86028:2000 z wyjątkiem pkt. 2.2f, 2.2g, 2.4","search_zh":"爆炸物 PN-C-86028:2000 z wyjątkiem pkt. 2.2f, 2.2g, 2.4","test_object_zh":"爆炸物"},{"_id":"6a5dc9a7f1c10c8ce8259ad6","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Materiały wybuchowe","test_object_en":"Explosives","methodology":"Wrażliwość materiałów wybuchowych na tarcie","methodology_en":"Friction sensitivity of explosives","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wrażliwość materiałów wybuchowych na tarcie","reference":"PN-EN-13631-3:2006","norm_bases":["PN-EN-13631-3:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały wybuchowe Wrażliwość materiałów wybuchowych na tarcie PN-EN-13631-3:2006 Materialy wybuchowe Wrazliwosc materialow wybuchowych na tarcie PN-EN-13631-3:2006","categories":["materials"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosives Friction sensitivity of explosives PN-EN-13631-3:2006","search_zh":"爆炸物 PN-EN-13631-3:2006","test_object_zh":"爆炸物"},{"_id":"6a5dc9a7f1c10c8ce8259ad7","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Materiały wybuchowe","test_object_en":"Explosives","methodology":"Wrażliwość materiałów wybuchowych na uderzenie","methodology_en":"Impact sensitivity of explosives","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wrażliwość materiałów wybuchowych na uderzenie","reference":"PN-EN 13631-4:2004","norm_bases":["PN-EN 13631-4:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały wybuchowe Wrażliwość materiałów wybuchowych na uderzenie PN-EN 13631-4:2004 Materialy wybuchowe Wrazliwosc materialow wybuchowych na uderzenie PN-EN 13631-4:2004","categories":["materials"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosives Impact sensitivity of explosives PN-EN 13631-4:2004","search_zh":"爆炸物 PN-EN 13631-4:2004","test_object_zh":"爆炸物"},{"_id":"6a5dc9a7f1c10c8ce8259ad8","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Materiały wybuchowe","test_object_en":"Explosives","methodology":"Gęstość materiałów wybuchowych","methodology_en":"Density of explosives","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Gęstość materiałów wybuchowych","reference":"PN-EN 13631-13:2005 zgodnie z pkt. 6.2","norm_bases":["PN-EN 13631-13:2005 zgodnie z pkt. 6.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały wybuchowe Gęstość materiałów wybuchowych PN-EN 13631-13:2005 zgodnie z pkt. 6.2 Materialy wybuchowe Gestosc materialow wybuchowych PN-EN 13631-13:2005 zgodnie z pkt. 6.2","categories":["materials"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosives Density of explosives PN-EN 13631-13:2005 zgodnie z pkt. 6.2","search_zh":"爆炸物 PN-EN 13631-13:2005 zgodnie z pkt. 6.2","test_object_zh":"爆炸物"},{"_id":"6a5dc9a7f1c10c8ce8259ad9","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Materiały wybuchowe","test_object_en":"Explosives","methodology":"Stabilność termiczna materiałów wybuchowych, Próba Abla","methodology_en":"Thermal stability of explosives, Abel test","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stabilność termiczna materiałów wybuchowych, Próba Abla","reference":"PN-C-86013:2018-02 Z wyjątkiem pkt. 3.7, 3.8, 4.12, 5.1, 5.4, 5.5","norm_bases":["PN-C-86013:2018-02 Z wyjątkiem pkt. 3.7, 3.8, 4.12, 5.1, 5.4, 5.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały wybuchowe Stabilność termiczna materiałów wybuchowych, Próba Abla PN-C-86013:2018-02 Z wyjątkiem pkt. 3.7, 3.8, 4.12, 5.1, 5.4, 5.5 Materialy wybuchowe Stabilnosc termiczna materialow wybuchowych, Proba Abla PN-C-86013:2018-02 Z wyjatkiem pkt. 3.7, 3.8, 4.12, 5.1, 5.4, 5.5","categories":["materials"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosives Thermal stability of explosives, Abel test PN-C-86013:2018-02 Z wyjątkiem pkt. 3.7, 3.8, 4.12, 5.1, 5.4, 5.5","search_zh":"爆炸物 PN-C-86013:2018-02 Z wyjątkiem pkt. 3.7, 3.8, 4.12, 5.1, 5.4, 5.5","test_object_zh":"爆炸物"},{"_id":"6a5dc9a7f1c10c8ce8259ada","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Materiały wybuchowe","test_object_en":"Explosives","methodology":"Odporność na zapalenie lontem prochowym materiałów wybuchowych","methodology_en":"Resistance of explosives to ignition by safety fuse","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zapalenie lontem prochowym materiałów wybuchowych","reference":"JOZ-W.1/L/PB-MW.13 edycja 2 z 08.2023 r.","norm_bases":["JOZ-W.1/L/PB-MW.13 edycja 2 z 08.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały wybuchowe Odporność na zapalenie lontem prochowym materiałów wybuchowych JOZ-W.1/L/PB-MW.13 edycja 2 z 08.2023 r. Materialy wybuchowe Odpornosc na zapalenie lontem prochowym materialow wybuchowych JOZ-W.1/L/PB-MW.13 edycja 2 z 08.2023 r.","categories":["materials"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosives Resistance of explosives to ignition by safety fuse JOZ-W.1/L/PB-MW.13 edycja 2 z 08.2023 r.","search_zh":"爆炸物 JOZ-W.1/L/PB-MW.13 edycja 2 z 08.2023 r.","test_object_zh":"爆炸物"},{"_id":"6a5dc9a7f1c10c8ce8259adb","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Materiały wybuchowe","test_object_en":"Explosives","methodology":"Odporność na wodę materiałów wybuchowych","methodology_en":"Water resistance of explosives","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wodę materiałów wybuchowych","reference":"PN-EN 13631-5:2004","norm_bases":["PN-EN 13631-5:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały wybuchowe Odporność na wodę materiałów wybuchowych PN-EN 13631-5:2004 Materialy wybuchowe Odpornosc na wode materialow wybuchowych PN-EN 13631-5:2004","categories":["materials"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosives Water resistance of explosives PN-EN 13631-5:2004","search_zh":"爆炸物 PN-EN 13631-5:2004","test_object_zh":"爆炸物"},{"_id":"6a5dc9a7f1c10c8ce8259adc","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Materiały wybuchowe","test_object_en":"Explosives","methodology":"Odporność na składowanie termiczne","methodology_en":"Resistance to thermal storage","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na składowanie termiczne","reference":"PN-EN 13631-1:2006 | PN-EN 13631-7:2005 JOZ-W.1/L/PB-MW.19 edycja 2 z 08.2023 r.","norm_bases":["PN-EN 13631-1:2006","PN-EN 13631-7:2005 JOZ-W.1/L/PB-MW.19 edycja 2 z 08.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały wybuchowe Odporność na składowanie termiczne PN-EN 13631-1:2006 | PN-EN 13631-7:2005 JOZ-W.1/L/PB-MW.19 edycja 2 z 08.2023 r. Materialy wybuchowe Odpornosc na skladowanie termiczne PN-EN 13631-1:2006 | PN-EN 13631-7:2005 JOZ-W.1/L/PB-MW.19 edycja 2 z 08.2023 r.","categories":["materials"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosives Resistance to thermal storage PN-EN 13631-1:2006 | PN-EN 13631-7:2005 JOZ-W.1/L/PB-MW.19 edycja 2 z 08.2023 r.","search_zh":"爆炸物 PN-EN 13631-1:2006 | PN-EN 13631-7:2005 JOZ-W.1/L/PB-MW.19 edycja 2 z 08.2023 r.","test_object_zh":"爆炸物"},{"_id":"6a5dc9a7f1c10c8ce8259add","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Lonty detonujące","test_object_en":"Detonating cords","methodology":"Stabilność termiczna lontów detonujących i prochowych","methodology_en":"Thermal stability of detonating and safety fuses","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stabilność termiczna lontów detonujących i prochowych","reference":"PN-EN 13630-2:2004","norm_bases":["PN-EN 13630-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Lonty detonujące Stabilność termiczna lontów detonujących i prochowych PN-EN 13630-2:2004 Lonty detonujace Stabilnosc termiczna lontow detonujacych i prochowych PN-EN 13630-2:2004","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Detonating cords Thermal stability of detonating and safety fuses PN-EN 13630-2:2004","search_zh":"导爆索 PN-EN 13630-2:2004","test_object_zh":"导爆索"},{"_id":"6a5dc9a7f1c10c8ce8259ade","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Lonty detonujące","test_object_en":"Detonating cords","methodology":"Wrażliwość na tarcie rdzenia lontów detonujących","methodology_en":"Friction sensitivity of the core of detonating cords","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wrażliwość na tarcie rdzenia lontów detonujących","reference":"PN-EN 13630-3:2004","norm_bases":["PN-EN 13630-3:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Lonty detonujące Wrażliwość na tarcie rdzenia lontów detonujących PN-EN 13630-3:2004 Lonty detonujace Wrazliwosc na tarcie rdzenia lontow detonujacych PN-EN 13630-3:2004","categories":["other"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Detonating cords Friction sensitivity of the core of detonating cords PN-EN 13630-3:2004","search_zh":"导爆索 PN-EN 13630-3:2004","test_object_zh":"导爆索"},{"_id":"6a5dc9a7f1c10c8ce8259adf","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Lonty detonujące","test_object_en":"Detonating cords","methodology":"Wrażliwość lontów detonujących na uderzenie","methodology_en":"Impact sensitivity of detonating cords","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wrażliwość lontów detonujących na uderzenie","reference":"PN-EN 13630-4:2004","norm_bases":["PN-EN 13630-4:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Lonty detonujące Wrażliwość lontów detonujących na uderzenie PN-EN 13630-4:2004 Lonty detonujace Wrazliwosc lontow detonujacych na uderzenie PN-EN 13630-4:2004","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Detonating cords Impact sensitivity of detonating cords PN-EN 13630-4:2004","search_zh":"导爆索 PN-EN 13630-4:2004","test_object_zh":"导爆索"},{"_id":"6a5dc9a7f1c10c8ce8259ae0","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Lonty detonujące","test_object_en":"Detonating cords","methodology":"Prędkość detonacji lontów detonujących","methodology_en":"Detonation velocity of detonating cords","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Prędkość detonacji lontów detonujących","reference":"PN-EN 13630-11:2004","norm_bases":["PN-EN 13630-11:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Lonty detonujące Prędkość detonacji lontów detonujących PN-EN 13630-11:2004 Lonty detonujace Predkosc detonacji lontow detonujacych PN-EN 13630-11:2004","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Detonating cords Detonation velocity of detonating cords PN-EN 13630-11:2004","search_zh":"导爆索 PN-EN 13630-11:2004","test_object_zh":"导爆索"},{"_id":"6a5dc9a7f1c10c8ce8259ae1","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Lonty detonujące","test_object_en":"Detonating cords","methodology":"Odporność na składowanie termiczne","methodology_en":"Resistance to thermal storage","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na składowanie termiczne","reference":"PN-C-86069:1998 JOZ-W.1/L/PB-MW.19 edycja 2 z 08.2023 r.","norm_bases":["PN-C-86069:1998 JOZ-W.1/L/PB-MW.19 edycja 2 z 08.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Lonty detonujące Odporność na składowanie termiczne PN-C-86069:1998 JOZ-W.1/L/PB-MW.19 edycja 2 z 08.2023 r. Lonty detonujace Odpornosc na skladowanie termiczne PN-C-86069:1998 JOZ-W.1/L/PB-MW.19 edycja 2 z 08.2023 r.","categories":["other"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Detonating cords Resistance to thermal storage PN-C-86069:1998 JOZ-W.1/L/PB-MW.19 edycja 2 z 08.2023 r.","search_zh":"导爆索 PN-C-86069:1998 JOZ-W.1/L/PB-MW.19 edycja 2 z 08.2023 r.","test_object_zh":"导爆索"},{"_id":"6a5dc9a7f1c10c8ce8259ae2","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Zapalniki i przekaźniki","test_object_en":"Detonators and relays","methodology":"Stabilność termiczna zapalników elektrycznych","methodology_en":"Thermal stability of electric detonators","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stabilność termiczna zapalników elektrycznych","reference":"PN-EN 13763-2:2004","norm_bases":["PN-EN 13763-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zapalniki i przekaźniki Stabilność termiczna zapalników elektrycznych PN-EN 13763-2:2004 Zapalniki i przekazniki Stabilnosc termiczna zapalnikow elektrycznych PN-EN 13763-2:2004","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Detonators and relays Thermal stability of electric detonators PN-EN 13763-2:2004","search_zh":"雷管与继爆器 PN-EN 13763-2:2004","test_object_zh":"雷管与继爆器"},{"_id":"6a5dc9a7f1c10c8ce8259ae3","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Zapalniki i przekaźniki","test_object_en":"Detonators and relays","methodology":"Dokładność opóźnienia zapalników","methodology_en":"Accuracy of detonator delay","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Dokładność opóźnienia zapalników","reference":"PN-EN 13763-16:2005","norm_bases":["PN-EN 13763-16:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zapalniki i przekaźniki Dokładność opóźnienia zapalników PN-EN 13763-16:2005 Zapalniki i przekazniki Dokladnosc opoznienia zapalnikow PN-EN 13763-16:2005","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Detonators and relays Accuracy of detonator delay PN-EN 13763-16:2005","search_zh":"雷管与继爆器 PN-EN 13763-16:2005","test_object_zh":"雷管与继爆器"},{"_id":"6a5dc9a7f1c10c8ce8259ae4","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Zapalniki i przekaźniki","test_object_en":"Detonators and relays","methodology":"Prąd nieodpalający zapalniki elektryczne","methodology_en":"Non-firing current of electric detonators","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Prąd nieodpalający zapalniki elektryczne","reference":"PN-EN 13763-17:2005","norm_bases":["PN-EN 13763-17:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zapalniki i przekaźniki Prąd nieodpalający zapalniki elektryczne PN-EN 13763-17:2005 Zapalniki i przekazniki Prad nieodpalajacy zapalniki elektryczne PN-EN 13763-17:2005","categories":["other"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Detonators and relays Non-firing current of electric detonators PN-EN 13763-17:2005","search_zh":"雷管与继爆器 PN-EN 13763-17:2005","test_object_zh":"雷管与继爆器"},{"_id":"6a5dc9a7f1c10c8ce8259ae5","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Zapalniki i przekaźniki","test_object_en":"Detonators and relays","methodology":"Prąd odpalający serię zapalników elektrycznych","methodology_en":"Firing current of a series of electric detonators","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Prąd odpalający serię zapalników elektrycznych","reference":"PN-EN 13763-18:2005","norm_bases":["PN-EN 13763-18:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zapalniki i przekaźniki Prąd odpalający serię zapalników elektrycznych PN-EN 13763-18:2005 Zapalniki i przekazniki Prad odpalajacy serie zapalnikow elektrycznych PN-EN 13763-18:2005","categories":["other"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Detonators and relays Firing current of a series of electric detonators PN-EN 13763-18:2005","search_zh":"雷管与继爆器 PN-EN 13763-18:2005","test_object_zh":"雷管与继爆器"},{"_id":"6a5dc9a7f1c10c8ce8259ae6","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Zapalniki i przekaźniki","test_object_en":"Detonators and relays","methodology":"Wielkość impulsu odpalającego zapalniki elektryczne","methodology_en":"Magnitude of the firing impulse for electric detonators","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wielkość impulsu odpalającego zapalniki elektryczne","reference":"PN-EN 13763-19:2005","norm_bases":["PN-EN 13763-19:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zapalniki i przekaźniki Wielkość impulsu odpalającego zapalniki elektryczne PN-EN 13763-19:2005 Zapalniki i przekazniki Wielkosc impulsu odpalajacego zapalniki elektryczne PN-EN 13763-19:2005","categories":["other"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Detonators and relays Magnitude of the firing impulse for electric detonators PN-EN 13763-19:2005","search_zh":"雷管与继爆器 PN-EN 13763-19:2005","test_object_zh":"雷管与继爆器"},{"_id":"6a5dc9a7f1c10c8ce8259ae7","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Zapalniki i przekaźniki","test_object_en":"Detonators and relays","methodology":"Rezystancja całkowita zapalników elektrycznych","methodology_en":"Total resistance of electric detonators","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja całkowita zapalników elektrycznych","reference":"PN-EN 13763-20:2005","norm_bases":["PN-EN 13763-20:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zapalniki i przekaźniki Rezystancja całkowita zapalników elektrycznych PN-EN 13763-20:2005 Zapalniki i przekazniki Rezystancja calkowita zapalnikow elektrycznych PN-EN 13763-20:2005","categories":["other"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Detonators and relays Total resistance of electric detonators PN-EN 13763-20:2005","search_zh":"雷管与继爆器 PN-EN 13763-20:2005","test_object_zh":"雷管与继爆器"},{"_id":"6a5dc9a7f1c10c8ce8259ae8","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Zapalniki i przekaźniki","test_object_en":"Detonators and relays","methodology":"Napięcie przebicia zapalników elektrycznych","methodology_en":"Breakdown voltage of electric detonators","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie przebicia zapalników elektrycznych","reference":"PN-EN 13763-21:2005","norm_bases":["PN-EN 13763-21:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zapalniki i przekaźniki Napięcie przebicia zapalników elektrycznych PN-EN 13763-21:2005 Zapalniki i przekazniki Napiecie przebicia zapalnikow elektrycznych PN-EN 13763-21:2005","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Detonators and relays Breakdown voltage of electric detonators PN-EN 13763-21:2005","search_zh":"雷管与继爆器 PN-EN 13763-21:2005","test_object_zh":"雷管与继爆器"},{"_id":"6a5dc9a7f1c10c8ce8259ae9","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Zapalniki i przekaźniki","test_object_en":"Detonators and relays","methodology":"Prędkość fali uderzeniowej w rurce detonującej","methodology_en":"Shock wave velocity in a shock tube","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Prędkość fali uderzeniowej w rurce detonującej","reference":"PN-EN 13763-23:2004","norm_bases":["PN-EN 13763-23:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zapalniki i przekaźniki Prędkość fali uderzeniowej w rurce detonującej PN-EN 13763-23:2004 Zapalniki i przekazniki Predkosc fali uderzeniowej w rurce detonujacej PN-EN 13763-23:2004","categories":["other"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Detonators and relays Shock wave velocity in a shock tube PN-EN 13763-23:2004","search_zh":"雷管与继爆器 PN-EN 13763-23:2004","test_object_zh":"雷管与继爆器"},{"_id":"6a5dc9a7f1c10c8ce8259aea","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i podzespoły elektryczne i nieelektryczne w wykonaniu przeciwwybuchowym","test_object_en":"Electrical and non-electrical equipment and components of explosion-proof design","methodology":"Wymiary liniowe w zakresie od 0,01 mm do 4 m – pomiar bezpośredni","methodology_en":"Linear dimensions in the range from 0,01 mm to 4 m – direct measurement","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wymiary liniowe w zakresie od 0,01 mm do 4 m – pomiar bezpośredni","reference":"PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN 60079-7:2010 | EN 60079-7:2007 | IEC 60079-7:2006 ed.4.0 | PN-EN 60079-7:2016-02 | EN 60079-7:2015 | IEC 60079-7:2015 ed.5.0 | IEC 60079-7:2015+AMD1:2017 CSV ed.5.1 | PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011ed.6.0 | PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000 | PN-EN 14986:2009 | EN 14986:2007 | PN-EN 14986:2017-02 | EN 14986:2017","norm_bases":["PN-EN 60079-0:2013-03","EN 60079-0:2012","IEC 60079-0:2011 ed.6.0","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012/A11:2013","IEC 60079-0:2017 ed.7.0","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017","PN-EN 60079-1:2010","EN 60079-1:2007","IEC 60079-1:2007 ed.6.0","PN-EN 60079-1:2014-12","EN 60079-1:2014","IEC 60079-1:2014 ed.7.0","PN-EN 60079-7:2010","EN 60079-7:2007","IEC 60079-7:2006 ed.4.0","PN-EN 60079-7:2016-02","EN 60079-7:2015","IEC 60079-7:2015 ed.5.0","IEC 60079-7:2015+AMD1:2017 CSV ed.5.1","PN-EN 60079-11:2012","EN 60079-11:2012","IEC 60079-11:2011ed.6.0","PN-EN ISO 16852:2012","EN ISO 16852:2010","PN-EN ISO 16852:2017-02","EN ISO 16852:2016","ISO 16852:2016","PN-EN 1834-1:2002","EN 1834-1:2000","PN-EN 1834-2:2002","EN 1834-2:2000","PN-EN 14986:2009","EN 14986:2007","PN-EN 14986:2017-02","EN 14986:2017"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i podzespoły elektryczne i nieelektryczne w wykonaniu przeciwwybuchowym Wymiary liniowe w zakresie od 0,01 mm do 4 m – pomiar bezpośredni PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN 60079-7:2010 | EN 60079-7:2007 | IEC 60079-7:2006 ed.4.0 | PN-EN 60079-7:2016-02 | EN 60079-7:2015 | IEC 60079-7:2015 ed.5.0 | IEC 60079-7:2015+AMD1:2017 CSV ed.5.1 | PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011ed.6.0 | PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000 | PN-EN 14986:2009 | EN 14986:2007 | PN-EN 14986:2017-02 | EN 14986:2017 Urzadzenia i podzespoly elektryczne i nieelektryczne w wykonaniu przeciwwybuchowym Wymiary liniowe w zakresie od 0,01 mm do 4 m – pomiar bezposredni PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN 60079-7:2010 | EN 60079-7:2007 | IEC 60079-7:2006 ed.4.0 | PN-EN 60079-7:2016-02 | EN 60079-7:2015 | IEC 60079-7:2015 ed.5.0 | IEC 60079-7:2015+AMD1:2017 CSV ed.5.1 | PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011ed.6.0 | PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000 | PN-EN 14986:2009 | EN 14986:2007 | PN-EN 14986:2017-02 | EN 14986:2017","categories":["other"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical and non-electrical equipment and components of explosion-proof design Linear dimensions in the range from 0,01 mm to 4 m – direct measurement PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN 60079-7:2010 | EN 60079-7:2007 | IEC 60079-7:2006 ed.4.0 | PN-EN 60079-7:2016-02 | EN 60079-7:2015 | IEC 60079-7:2015 ed.5.0 | IEC 60079-7:2015+AMD1:2017 CSV ed.5.1 | PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011ed.6.0 | PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000 | PN-EN 14986:2009 | EN 14986:2007 | PN-EN 14986:2017-02 | EN 14986:2017"},{"_id":"6a5dc9a7f1c10c8ce8259aeb","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Obudowy urządzeń elektrycznych i nieelektrycznych w wykonaniu zwykłym oraz przeciwwybuchowym","test_object_en":"Enclosures of electrical and non-electrical equipment in standard and explosion-proof design","methodology":"Stopień ochrony IP – metoda bezpośrednia","methodology_en":"IP degree of protection – direct method","parameters":[{"name":"Zakres","range":"od IP0X do IP6X"},{"name":"od IPX3 do IPX8"}],"parameters_en":[{"name":"Range","range":"od IP0X do IP6X"},{"name":"from IPX3 to IPX8"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stopień ochrony IP – metoda bezpośrednia\nZakres:\nZakres od IP0X do IP6X\nod IPX3 do IPX8","reference":"PN-EN 60529:2003 | EN 60529:1991+A1:2000 | IEC 60529:2001 | PN-EN 60529:2003/A2:2014-07 | EN 60529:1991/A2:2013 | IEC 60529:1989/AMD2:2013","norm_bases":["PN-EN 60529:2003","EN 60529:1991+A1:2000","IEC 60529:2001","PN-EN 60529:2003/A2:2014-07","EN 60529:1991/A2:2013","IEC 60529:1989/AMD2:2013"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obudowy urządzeń elektrycznych i nieelektrycznych w wykonaniu zwykłym oraz przeciwwybuchowym Stopień ochrony IP – metoda bezpośrednia\nZakres:\nZakres od IP0X do IP6X\nod IPX3 do IPX8 PN-EN 60529:2003 | EN 60529:1991+A1:2000 | IEC 60529:2001 | PN-EN 60529:2003/A2:2014-07 | EN 60529:1991/A2:2013 | IEC 60529:1989/AMD2:2013 Obudowy urzadzen elektrycznych i nieelektrycznych w wykonaniu zwyklym oraz przeciwwybuchowym Stopien ochrony IP – metoda bezposrednia\nZakres:\nZakres od IP0X do IP6X\nod IPX3 do IPX8 PN-EN 60529:2003 | EN 60529:1991+A1:2000 | IEC 60529:2001 | PN-EN 60529:2003/A2:2014-07 | EN 60529:1991/A2:2013 | IEC 60529:1989/AMD2:2013","categories":["other"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Enclosures of electrical and non-electrical equipment in standard and explosion-proof design IP degree of protection – direct method Range from IPX3 to IPX8 PN-EN 60529:2003 | EN 60529:1991+A1:2000 | IEC 60529:2001 | PN-EN 60529:2003/A2:2014-07 | EN 60529:1991/A2:2013 | IEC 60529:1989/AMD2:2013","parameters_zh":[{"name":"范围","range":"od IP0X do IP6X"},{"name":"od IPX3 do IPX8"}],"search_zh":"范围 PN-EN 60529:2003 | EN 60529:1991+A1:2000 | IEC 60529:2001 | PN-EN 60529:2003/A2:2014-07 | EN 60529:1991/A2:2013 | IEC 60529:1989/AMD2:2013"},{"_id":"6a5dc9a7f1c10c8ce8259aec","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Obudowy i osłony maszyn elektrycznych wirujących w wykonaniu zwykłym oraz przeciwwybuchowym","test_object_en":"Enclosures and guards of rotating electrical machines in standard and explosion-proof design","methodology":"Stopień ochrony IP – metoda bezpośrednia","methodology_en":"IP degree of protection – direct method","parameters":[{"name":"Zakres","range":"od IP0X do IP6X"},{"name":"od IPX3 do IPX8"}],"parameters_en":[{"name":"Range","range":"od IP0X do IP6X"},{"name":"from IPX3 to IPX8"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stopień ochrony IP – metoda bezpośrednia\nZakres:\nZakres od IP0X do IP6X\nod IPX3 do IPX8","reference":"PN-EN 60034-5:2004+A1:2009 | EN 60034-5:2001+A1:2007 | IEC 60034-5:2000+A1:2006 ed.4.0 | PN-EN IEC 60034-5:2021-01 | EN IEC 60034-5:2020 | PN-EN IEC 60034-5:2021-01","norm_bases":["PN-EN 60034-5:2004+A1:2009","EN 60034-5:2001+A1:2007","IEC 60034-5:2000+A1:2006 ed.4.0","PN-EN IEC 60034-5:2021-01","EN IEC 60034-5:2020","PN-EN IEC 60034-5:2021-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Obudowy i osłony maszyn elektrycznych wirujących w wykonaniu zwykłym oraz przeciwwybuchowym Stopień ochrony IP – metoda bezpośrednia\nZakres:\nZakres od IP0X do IP6X\nod IPX3 do IPX8 PN-EN 60034-5:2004+A1:2009 | EN 60034-5:2001+A1:2007 | IEC 60034-5:2000+A1:2006 ed.4.0 | PN-EN IEC 60034-5:2021-01 | EN IEC 60034-5:2020 | PN-EN IEC 60034-5:2021-01 Obudowy i oslony maszyn elektrycznych wirujacych w wykonaniu zwyklym oraz przeciwwybuchowym Stopien ochrony IP – metoda bezposrednia\nZakres:\nZakres od IP0X do IP6X\nod IPX3 do IPX8 PN-EN 60034-5:2004+A1:2009 | EN 60034-5:2001+A1:2007 | IEC 60034-5:2000+A1:2006 ed.4.0 | PN-EN IEC 60034-5:2021-01 | EN IEC 60034-5:2020 | PN-EN IEC 60034-5:2021-01","categories":["other"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Enclosures and guards of rotating electrical machines in standard and explosion-proof design IP degree of protection – direct method Range from IPX3 to IPX8 PN-EN 60034-5:2004+A1:2009 | EN 60034-5:2001+A1:2007 | IEC 60034-5:2000+A1:2006 ed.4.0 | PN-EN IEC 60034-5:2021-01 | EN IEC 60034-5:2020 | PN-EN IEC 60034-5:2021-01","parameters_zh":[{"name":"范围","range":"od IP0X do IP6X"},{"name":"od IPX3 do IPX8"}],"search_zh":"范围 PN-EN 60034-5:2004+A1:2009 | EN 60034-5:2001+A1:2007 | IEC 60034-5:2000+A1:2006 ed.4.0 | PN-EN IEC 60034-5:2021-01 | EN IEC 60034-5:2020 | PN-EN IEC 60034-5:2021-01"},{"_id":"6a5dc9a7f1c10c8ce8259aed","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Materiały elektroizolacyjne stałe","test_object_en":"Solid electrical insulating materials","methodology":"Odporność na prądy pełzające – metoda bezpośrednia","methodology_en":"Resistance to tracking – direct method","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na prądy pełzające – metoda bezpośrednia","reference":"PN-EN 60112:2003 +A1:2010 | EN 60112:2003+A1:2009 | IEC 60112:2003+AMD1:2009 CSV ed 4.1 | PN-EN 60112:2021-07 EN-IEC 60112:2020 | IEC 60112:2020","norm_bases":["PN-EN 60112:2003 +A1:2010","EN 60112:2003+A1:2009","IEC 60112:2003+AMD1:2009 CSV ed 4.1","PN-EN 60112:2021-07 EN-IEC 60112:2020","IEC 60112:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały elektroizolacyjne stałe Odporność na prądy pełzające – metoda bezpośrednia PN-EN 60112:2003 +A1:2010 | EN 60112:2003+A1:2009 | IEC 60112:2003+AMD1:2009 CSV ed 4.1 | PN-EN 60112:2021-07 EN-IEC 60112:2020 | IEC 60112:2020 Materialy elektroizolacyjne stale Odpornosc na prady pelzajace – metoda bezposrednia PN-EN 60112:2003 +A1:2010 | EN 60112:2003+A1:2009 | IEC 60112:2003+AMD1:2009 CSV ed 4.1 | PN-EN 60112:2021-07 EN-IEC 60112:2020 | IEC 60112:2020","categories":["materials"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid electrical insulating materials Resistance to tracking – direct method PN-EN 60112:2003 +A1:2010 | EN 60112:2003+A1:2009 | IEC 60112:2003+AMD1:2009 CSV ed 4.1 | PN-EN 60112:2021-07 EN-IEC 60112:2020 | IEC 60112:2020","search_zh":"固体电绝缘材料 PN-EN 60112:2003 +A1:2010 | EN 60112:2003+A1:2009 | IEC 60112:2003+AMD1:2009 CSV ed 4.1 | PN-EN 60112:2021-07 EN-IEC 60112:2020 | IEC 60112:2020","test_object_zh":"固体电绝缘材料"},{"_id":"6a5dc9a7f1c10c8ce8259aee","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia grupy I kategorii M1 przeznaczone do pracy ciągłej w atmosferach zagrożonych metanem i/lub pyłem węglowym","test_object_en":"Group I category M1 equipment intended for continuous operation in atmospheres endangered by methane and/or coal dust","methodology":"Zdolność zapalenia mieszaniny testowej przez gorące druty/pellistory – metoda bezpośrednia","methodology_en":"Ability of hot wires/pellistors to ignite the test mixture – direct method","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność zapalenia mieszaniny testowej przez gorące druty/pellistory – metoda bezpośrednia","reference":"PN-EN 50303:2004 | EN 50303:2000","norm_bases":["PN-EN 50303:2004","EN 50303:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia grupy I kategorii M1 przeznaczone do pracy ciągłej w atmosferach zagrożonych metanem i/lub pyłem węglowym Zdolność zapalenia mieszaniny testowej przez gorące druty/pellistory – metoda bezpośrednia PN-EN 50303:2004 | EN 50303:2000 Urzadzenia grupy I kategorii M1 przeznaczone do pracy ciaglej w atmosferach zagrozonych metanem i/lub pylem weglowym Zdolnosc zapalenia mieszaniny testowej przez gorace druty/pellistory – metoda bezposrednia PN-EN 50303:2004 | EN 50303:2000","categories":["other"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Group I category M1 equipment intended for continuous operation in atmospheres endangered by methane and/or coal dust Ability of hot wires/pellistors to ignite the test mixture – direct method PN-EN 50303:2004 | EN 50303:2000"},{"_id":"6a5dc9a7f1c10c8ce8259aef","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia grupy I kategorii M1 przeznaczone do pracy ciągłej w atmosferach zagrożonych metanem i/lub pyłem węglowym","test_object_en":"Group I category M1 equipment intended for continuous operation in atmospheres endangered by methane and/or coal dust","methodology":"Nagrzewanie pellistorów – metoda bezpośrednia: zakres do +600oC","methodology_en":"Heating of pellistors – direct method: range up to +600oC","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Nagrzewanie pellistorów – metoda bezpośrednia: zakres do +600oC","reference":"PN-EN 50303:2004 | EN 50303:2000","norm_bases":["PN-EN 50303:2004","EN 50303:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia grupy I kategorii M1 przeznaczone do pracy ciągłej w atmosferach zagrożonych metanem i/lub pyłem węglowym Nagrzewanie pellistorów – metoda bezpośrednia: zakres do +600oC PN-EN 50303:2004 | EN 50303:2000 Urzadzenia grupy I kategorii M1 przeznaczone do pracy ciaglej w atmosferach zagrozonych metanem i/lub pylem weglowym Nagrzewanie pellistorow – metoda bezposrednia: zakres do +600oC PN-EN 50303:2004 | EN 50303:2000","categories":["other"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Group I category M1 equipment intended for continuous operation in atmospheres endangered by methane and/or coal dust Heating of pellistors – direct method: range up to +600oC PN-EN 50303:2004 | EN 50303:2000"},{"_id":"6a5dc9a7f1c10c8ce8259af0","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Wytrzymałość na uderzenia – badanie bezpośrednie udarem; wartość energii uderzenia w zakresie od 1 J do 40 J","methodology_en":"Impact resistance – direct impact test; impact energy value in the range from 1 J to 40 J","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na uderzenia – badanie bezpośrednie udarem; wartość energii uderzenia w zakresie od 1 J do 40 J","reference":"PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","norm_bases":["PN-EN 60079-0:2013-03","EN 60079-0:2012","IEC 60079-0:2011ed.6.0","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012/A11:2013","IEC 60079-0:2017 ed.7.0","PN-EN ISO 80079-36:2016-07","EN ISO 80079-36:2016","ISO 80079-36:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Wytrzymałość na uderzenia – badanie bezpośrednie udarem; wartość energii uderzenia w zakresie od 1 J do 40 J PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Wytrzymalosc na uderzenia – badanie bezposrednie udarem; wartosc energii uderzenia w zakresie od 1 J do 40 J PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","categories":["other"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Impact resistance – direct impact test; impact energy value in the range from 1 J to 40 J PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259af1","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Wytrzymałość na spadek swobodny – badanie bezpośrednie poprzez upadek na betonowe podłoże","methodology_en":"Resistance to free fall – direct test by dropping onto a concrete floor","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na spadek swobodny – badanie bezpośrednie poprzez upadek na betonowe podłoże","reference":"PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","norm_bases":["PN-EN 60079-0:2013-03","EN 60079-0:2012","IEC 60079-0:2011 ed.6.0","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012/A11:2013","IEC 60079-0:2017 ed.7.0","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017","PN-EN ISO 80079-36:2016-07","EN ISO 80079-36:2016","ISO 80079-36:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Wytrzymałość na spadek swobodny – badanie bezpośrednie poprzez upadek na betonowe podłoże PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Wytrzymalosc na spadek swobodny – badanie bezposrednie poprzez upadek na betonowe podloze PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","categories":["construction"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Resistance to free fall – direct test by dropping onto a concrete floor PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259af2","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Odporność elementów na udar cieplny – bezpośrednie oddziaływanie strugą wody na rozgrzany element","methodology_en":"Resistance of components to thermal shock – direct action of a water jet on a heated component","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność elementów na udar cieplny – bezpośrednie oddziaływanie strugą wody na rozgrzany element","reference":"PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","norm_bases":["PN-EN 60079-0:2013-03","EN 60079-0:2012","IEC 60079-0:2011ed.6.0","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012/A11:2013","IEC 60079-0:2017 ed.7.0","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017","PN-EN ISO 80079-36:2016-07","EN ISO 80079-36:2016","ISO 80079-36:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Odporność elementów na udar cieplny – bezpośrednie oddziaływanie strugą wody na rozgrzany element PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Odpornosc elementow na udar cieplny – bezposrednie oddzialywanie struga wody na rozgrzany element PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Resistance of components to thermal shock – direct action of a water jet on a heated component PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259af3","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Zadławienie i mocowanie wpustów kablowych – badanie bezpośrednie przez przyłożenie siły: wartość siły w zakresie od 1 N do 5000 N","methodology_en":"Clamping and fixing of cable entries – direct test by applying a force: force value in the range from 1 N to 5000 N","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zadławienie i mocowanie wpustów kablowych – badanie bezpośrednie przez przyłożenie siły: wartość siły w zakresie od 1 N do 5000 N","reference":"PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","norm_bases":["PN-EN 60079-0:2013-03","EN 60079-0:2012","IEC 60079-0:2011ed.6.0","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012/A11:2013","IEC 60079-0:2017 ed.7.0","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Zadławienie i mocowanie wpustów kablowych – badanie bezpośrednie przez przyłożenie siły: wartość siły w zakresie od 1 N do 5000 N PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Zadlawienie i mocowanie wpustow kablowych – badanie bezposrednie przez przylozenie sily: wartosc sily w zakresie od 1 N do 5000 N PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","categories":["other"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Clamping and fixing of cable entries – direct test by applying a force: force value in the range from 1 N to 5000 N PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259af4","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Zapalanie mieszaniny wybuchowej przez małe elementy – badanie bezpośrednie w mieszaninie gazowej","methodology_en":"Ignition of an explosive mixture by small components – direct test in a gas mixture","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zapalanie mieszaniny wybuchowej przez małe elementy – badanie bezpośrednie w mieszaninie gazowej","reference":"PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","norm_bases":["PN-EN 60079-0:2013-03","EN 60079-0:2012","IEC 60079-0:2011ed.6.0","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012/A11:2013","IEC 60079-0:2017 ed.7.0","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Zapalanie mieszaniny wybuchowej przez małe elementy – badanie bezpośrednie w mieszaninie gazowej PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Zapalanie mieszaniny wybuchowej przez male elementy – badanie bezposrednie w mieszaninie gazowej PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","categories":["other"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Ignition of an explosive mixture by small components – direct test in a gas mixture PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259af5","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Ciągłość uziemienia – badanie poprzez pomiar napięcia i prądu","methodology_en":"Earth continuity – test by measurement of voltage and current","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciągłość uziemienia – badanie poprzez pomiar napięcia i prądu","reference":"PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","norm_bases":["PN-EN 60079-0:2013-03","EN 60079-0:2012","IEC 60079-0:2011ed.6.0","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012/A11:2013","IEC 60079-0:2017 ed.7.0","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Ciągłość uziemienia – badanie poprzez pomiar napięcia i prądu PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Ciaglosc uziemienia – badanie poprzez pomiar napiecia i pradu PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","categories":["other"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Earth continuity – test by measurement of voltage and current PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259af6","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Odporność na czynniki chemiczne – oddziaływanie bezpośrednie czynników chemicznych","methodology_en":"Resistance to chemical agents – direct action of chemical agents","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na czynniki chemiczne – oddziaływanie bezpośrednie czynników chemicznych","reference":"PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","norm_bases":["PN-EN 60079-0:2013-03","EN 60079-0:2012","IEC 60079-0:2011ed.6.0","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012/A11:2013","IEC 60079-0:2017 ed.7.0","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017","PN-EN ISO 80079-36:2016-07","EN ISO 80079-36:2016","ISO 80079-36:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Odporność na czynniki chemiczne – oddziaływanie bezpośrednie czynników chemicznych PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Odpornosc na czynniki chemiczne – oddzialywanie bezposrednie czynnikow chemicznych PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","categories":["other"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Resistance to chemical agents – direct action of chemical agents PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259af7","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Temperatura elementów – pomiar bezpośredni temperatury i przyrostów temperatury w zakresie: -50oC ÷ +600oC","methodology_en":"Temperature of components – direct measurement of temperature and temperature rise in the range: -50oC ÷ +600oC","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura elementów – pomiar bezpośredni temperatury i przyrostów temperatury w zakresie: -50oC ÷ +600oC","reference":"PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016 | PN-EN 60079-5:2010 | EN 60079-5:2007 | IEC 60079-5:2007 ed.3.0 | PN-EN 60079-5:2015-08 | EN 60079-5:2015 | IEC 60079-5:2015 ed.4.0 | PN-EN ISO 80079-37:2016-07 | EN ISO 80079-37:2016 | ISO 80079-37:2016","norm_bases":["PN-EN 60079-0:2013-03","EN 60079-0:2012","IEC 60079-0:2011ed.6.0","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012/A11:2013","IEC 60079-0:2017 ed.7.0","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017","PN-EN ISO 80079-36:2016-07","EN ISO 80079-36:2016","ISO 80079-36:2016","PN-EN 60079-5:2010","EN 60079-5:2007","IEC 60079-5:2007 ed.3.0","PN-EN 60079-5:2015-08","EN 60079-5:2015","IEC 60079-5:2015 ed.4.0","PN-EN ISO 80079-37:2016-07","EN ISO 80079-37:2016","ISO 80079-37:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Temperatura elementów – pomiar bezpośredni temperatury i przyrostów temperatury w zakresie: -50oC ÷ +600oC PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016 | PN-EN 60079-5:2010 | EN 60079-5:2007 | IEC 60079-5:2007 ed.3.0 | PN-EN 60079-5:2015-08 | EN 60079-5:2015 | IEC 60079-5:2015 ed.4.0 | PN-EN ISO 80079-37:2016-07 | EN ISO 80079-37:2016 | ISO 80079-37:2016 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Temperatura elementow – pomiar bezposredni temperatury i przyrostow temperatury w zakresie: -50oC ÷ +600oC PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016 | PN-EN 60079-5:2010 | EN 60079-5:2007 | IEC 60079-5:2007 ed.3.0 | PN-EN 60079-5:2015-08 | EN 60079-5:2015 | IEC 60079-5:2015 ed.4.0 | PN-EN ISO 80079-37:2016-07 | EN ISO 80079-37:2016 | ISO 80079-37:2016","categories":["other"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Temperature of components – direct measurement of temperature and temperature rise in the range: -50oC ÷ +600oC PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016 | PN-EN 60079-5:2010 | EN 60079-5:2007 | IEC 60079-5:2007 ed.3.0 | PN-EN 60079-5:2015-08 | EN 60079-5:2015 | IEC 60079-5:2015 ed.4.0 | PN-EN ISO 80079-37:2016-07 | EN ISO 80079-37:2016 | ISO 80079-37:2016","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016 | PN-EN 60079-5:2010 | EN 60079-5:2007 | IEC 60079-5:2007 ed.3.0 | PN-EN 60079-5:2015-08 | EN 60079-5:2015 | IEC 60079-5:2015 ed.4.0 | PN-EN ISO 80079-37:2016-07 | EN ISO 80079-37:2016 | ISO 80079-37:2016","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259af8","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Temperatura elementów – pomiar bezpośredni temperatury i przyrostów temperatury w zakresie: -50oC ÷ +600oC","methodology_en":"Temperature of components – direct measurement of temperature and temperature rise in the range: -50oC ÷ +600oC","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura elementów – pomiar bezpośredni temperatury i przyrostów temperatury w zakresie: -50oC ÷ +600oC","reference":"PN-EN 60079-7:2010 | EN 60079-7:2007 | IEC 60079-7:2006 ed.4.0 | PN-EN 60079-7:2016-02, | EN 60079-7:2015, | IEC 60079-7:2015 ed.5.0 | IEC 60079-7:2015+AMD1:2017 CSV ed.5.1 | PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014 ed. 4.0 | IEC 60079-18:2014+AMD1:2017 CSV ed.4.1 | PN-EN 60079-31:2011 | EN 60079-31:2009 | IEC 60079-31:2008 ed.1.0 | PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 ed. 2.0 | PN-EN 60079-35-1:2011 | EN 60079-35-1:2011 | IEC 60079-35-1:2011ed.1.0","norm_bases":["PN-EN 60079-7:2010","EN 60079-7:2007","IEC 60079-7:2006 ed.4.0","PN-EN 60079-7:2016-02,","EN 60079-7:2015,","IEC 60079-7:2015 ed.5.0","IEC 60079-7:2015+AMD1:2017 CSV ed.5.1","PN-EN 60079-11:2012","EN 60079-11:2012","IEC 60079-11:2011 ed.6.0","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017","PN-EN 60079-18:2011","EN 60079-18:2009","IEC 60079-18:2009+AC1:2009 ed.3.0","PN-EN 60079-18:2015-06","EN 60079-18:2015,","IEC 60079-18:2014 ed. 4.0","IEC 60079-18:2014+AMD1:2017 CSV ed.4.1","PN-EN 60079-31:2011","EN 60079-31:2009","IEC 60079-31:2008 ed.1.0","PN-EN 60079-31:2014-10","EN 60079-31:2014","IEC 60079-31:2013 ed. 2.0","PN-EN 60079-35-1:2011","EN 60079-35-1:2011","IEC 60079-35-1:2011ed.1.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Temperatura elementów – pomiar bezpośredni temperatury i przyrostów temperatury w zakresie: -50oC ÷ +600oC PN-EN 60079-7:2010 | EN 60079-7:2007 | IEC 60079-7:2006 ed.4.0 | PN-EN 60079-7:2016-02, | EN 60079-7:2015, | IEC 60079-7:2015 ed.5.0 | IEC 60079-7:2015+AMD1:2017 CSV ed.5.1 | PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014 ed. 4.0 | IEC 60079-18:2014+AMD1:2017 CSV ed.4.1 | PN-EN 60079-31:2011 | EN 60079-31:2009 | IEC 60079-31:2008 ed.1.0 | PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 ed. 2.0 | PN-EN 60079-35-1:2011 | EN 60079-35-1:2011 | IEC 60079-35-1:2011ed.1.0 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Temperatura elementow – pomiar bezposredni temperatury i przyrostow temperatury w zakresie: -50oC ÷ +600oC PN-EN 60079-7:2010 | EN 60079-7:2007 | IEC 60079-7:2006 ed.4.0 | PN-EN 60079-7:2016-02, | EN 60079-7:2015, | IEC 60079-7:2015 ed.5.0 | IEC 60079-7:2015+AMD1:2017 CSV ed.5.1 | PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014 ed. 4.0 | IEC 60079-18:2014+AMD1:2017 CSV ed.4.1 | PN-EN 60079-31:2011 | EN 60079-31:2009 | IEC 60079-31:2008 ed.1.0 | PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 ed. 2.0 | PN-EN 60079-35-1:2011 | EN 60079-35-1:2011 | IEC 60079-35-1:2011ed.1.0","categories":["other"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Temperature of components – direct measurement of temperature and temperature rise in the range: -50oC ÷ +600oC PN-EN 60079-7:2010 | EN 60079-7:2007 | IEC 60079-7:2006 ed.4.0 | PN-EN 60079-7:2016-02, | EN 60079-7:2015, | IEC 60079-7:2015 ed.5.0 | IEC 60079-7:2015+AMD1:2017 CSV ed.5.1 | PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014 ed. 4.0 | IEC 60079-18:2014+AMD1:2017 CSV ed.4.1 | PN-EN 60079-31:2011 | EN 60079-31:2009 | IEC 60079-31:2008 ed.1.0 | PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 ed. 2.0 | PN-EN 60079-35-1:2011 | EN 60079-35-1:2011 | IEC 60079-35-1:2011ed.1.0","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-7:2010 | EN 60079-7:2007 | IEC 60079-7:2006 ed.4.0 | PN-EN 60079-7:2016-02, | EN 60079-7:2015, | IEC 60079-7:2015 ed.5.0 | IEC 60079-7:2015+AMD1:2017 CSV ed.5.1 | PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014 ed. 4.0 | IEC 60079-18:2014+AMD1:2017 CSV ed.4.1 | PN-EN 60079-31:2011 | EN 60079-31:2009 | IEC 60079-31:2008 ed.1.0 | PN-EN 60079-31:2014-10 | EN 60079-31:2014 | IEC 60079-31:2013 ed. 2.0 | PN-EN 60079-35-1:2011 | EN 60079-35-1:2011 | IEC 60079-35-1:2011ed.1.0","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259af9","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Odporność na czynniki klimatyczne materiałów niemetalowych – bezpośrednie oddziaływanie poprzez","methodology_en":"Resistance of non-metallic materials to climatic factors – direct action through","parameters":[{"name":"wilgotność","range":"(20÷100) % RH"},{"name":"temperaturę","range":"-50oC ÷ +170oC"}],"parameters_en":[{"name":"moisture","range":"(20÷100) % RH"},{"name":"temperature","range":"-50oC ÷ +170oC"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na czynniki klimatyczne materiałów niemetalowych – bezpośrednie oddziaływanie poprzez\nZakres:\nwilgotność (20÷100) % RH\ntemperaturę -50oC ÷ +170oC","reference":"PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","norm_bases":["PN-EN 60079-0:2013-03","EN 60079-0:2012","IEC 60079-0:2011ed.6.0","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012/A11:2013","IEC 60079-0:2017 ed.7.0","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017","PN-EN ISO 80079-36:2016-07","EN ISO 80079-36:2016","ISO 80079-36:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Odporność na czynniki klimatyczne materiałów niemetalowych – bezpośrednie oddziaływanie poprzez\nZakres:\nwilgotność (20÷100) % RH\ntemperaturę -50oC ÷ +170oC PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Odpornosc na czynniki klimatyczne materialow niemetalowych – bezposrednie oddzialywanie poprzez\nZakres:\nwilgotnosc (20÷100) % RH\ntemperature -50oC ÷ +170oC PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","categories":["materials"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Resistance of non-metallic materials to climatic factors – direct action through moisture temperature PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259afa","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Wytrzymałość na działanie momentu obrotowego – bezpośrednie przyłożenie momentu w zakresie od 2, Nm do 500 Nm","methodology_en":"Resistance to torque – direct application of torque in the range from 2, Nm to 500 Nm","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na działanie momentu obrotowego – bezpośrednie przyłożenie momentu w zakresie od 2, Nm do 500 Nm","reference":"PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-7:2010 | EN 60079-7:2007 | IEC 60079-7:2006 ed.4.0 | PN-EN 60079-7:2016-02, | EN 60079-7:2015, | IEC 60079-7:2015-06 ed.5.0 | IEC 60079-7:2015+AMD1:2017 CSV ed.5.1 | PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","norm_bases":["PN-EN 60079-0:2013-03","EN 60079-0:2012","IEC 60079-0:2011ed.6.0","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012/A11:2013","IEC 60079-0:2017 ed.7.0","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017","PN-EN 60079-7:2010","EN 60079-7:2007","IEC 60079-7:2006 ed.4.0","PN-EN 60079-7:2016-02,","EN 60079-7:2015,","IEC 60079-7:2015-06 ed.5.0","IEC 60079-7:2015+AMD1:2017 CSV ed.5.1","PN-EN 60079-15:2010","EN 60079-15:2010","IEC 60079-15:2010 ed.4.0","IEC 60079-15:2017 ed. 5.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Wytrzymałość na działanie momentu obrotowego – bezpośrednie przyłożenie momentu w zakresie od 2, Nm do 500 Nm PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-7:2010 | EN 60079-7:2007 | IEC 60079-7:2006 ed.4.0 | PN-EN 60079-7:2016-02, | EN 60079-7:2015, | IEC 60079-7:2015-06 ed.5.0 | IEC 60079-7:2015+AMD1:2017 CSV ed.5.1 | PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Wytrzymalosc na dzialanie momentu obrotowego – bezposrednie przylozenie momentu w zakresie od 2, Nm do 500 Nm PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-7:2010 | EN 60079-7:2007 | IEC 60079-7:2006 ed.4.0 | PN-EN 60079-7:2016-02, | EN 60079-7:2015, | IEC 60079-7:2015-06 ed.5.0 | IEC 60079-7:2015+AMD1:2017 CSV ed.5.1 | PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","categories":["other"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Resistance to torque – direct application of torque in the range from 2, Nm to 500 Nm PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-7:2010 | EN 60079-7:2007 | IEC 60079-7:2006 ed.4.0 | PN-EN 60079-7:2016-02, | EN 60079-7:2015, | IEC 60079-7:2015-06 ed.5.0 | IEC 60079-7:2015+AMD1:2017 CSV ed.5.1 | PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-7:2010 | EN 60079-7:2007 | IEC 60079-7:2006 ed.4.0 | PN-EN 60079-7:2016-02, | EN 60079-7:2015, | IEC 60079-7:2015-06 ed.5.0 | IEC 60079-7:2015+AMD1:2017 CSV ed.5.1 | PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259afb","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Elektryzacja materiału niemetalowego – oddziaływanie bezpośrednie poprzez pocieranie oraz ulot, Wielkość ładunku gromadzonego na powierzchni – pomiar pośredni, pomiar napięcia na określonej pojemności","methodology_en":"Electrostatic charging of non-metallic material – direct action by rubbing and by corona discharge, Amount of charge accumulated on the surface – indirect measurement, voltage measurement across a defined capacitance","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Elektryzacja materiału niemetalowego – oddziaływanie bezpośrednie poprzez pocieranie oraz ulot, Wielkość ładunku gromadzonego na powierzchni – pomiar pośredni, pomiar napięcia na określonej pojemności","reference":"PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","norm_bases":["PN-EN 60079-0:2013-03","EN 60079-0:2012","IEC 60079-0:2011 ed.6.0","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012/A11:2013","IEC 60079-0:2017 ed.7.0","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017","PN-EN ISO 80079-36:2016-07","EN ISO 80079-36:2016","ISO 80079-36:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Elektryzacja materiału niemetalowego – oddziaływanie bezpośrednie poprzez pocieranie oraz ulot, Wielkość ładunku gromadzonego na powierzchni – pomiar pośredni, pomiar napięcia na określonej pojemności PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Elektryzacja materialu niemetalowego – oddzialywanie bezposrednie poprzez pocieranie oraz ulot, Wielkosc ladunku gromadzonego na powierzchni – pomiar posredni, pomiar napiecia na okreslonej pojemnosci PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","categories":["materials"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Electrostatic charging of non-metallic material – direct action by rubbing and by corona discharge, Amount of charge accumulated on the surface – indirect measurement, voltage measurement across a defined capacitance PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259afc","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Parametry elektryczne: napięcie, prąd, moc, indukcyjność, pojemność, rezystancja, wytrzymałość elektryczna – pomiary bezpośrednie","methodology_en":"Electrical parameters: voltage, current, power, inductance, capacitance, resistance, electric strength – direct measurements","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Parametry elektryczne: napięcie, prąd, moc, indukcyjność, pojemność, rezystancja, wytrzymałość elektryczna – pomiary bezpośrednie","reference":"PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN 60079-7:2010 | EN 60079-7:2007 | IEC 60079-7:2006 ed.4.0 | PN-EN 60079-7:2016-02 | EN 60079-7:2015, | IEC 60079-7:2015 ed.5.0 | IEC 60079-7:2015+AMD1:2017 CSV ed.5.1 | PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0 | PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0 | PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014 ed. 4.0 EC 60079-18:2014+AMD1:2017 CSV ed.4.1","norm_bases":["PN-EN 60079-0:2013-03","EN 60079-0:2012","IEC 60079-0:2011 ed.6.0","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012/A11:2013","IEC 60079-0:2017 ed.7.0","PN-EN 60079-7:2010","EN 60079-7:2007","IEC 60079-7:2006 ed.4.0","PN-EN 60079-7:2016-02","EN 60079-7:2015,","IEC 60079-7:2015 ed.5.0","IEC 60079-7:2015+AMD1:2017 CSV ed.5.1","PN-EN 60079-11:2012","EN 60079-11:2012","IEC 60079-11:2011 ed.6.0","PN-EN 60079-15:2010","EN 60079-15:2010","IEC 60079-15:2010 ed.4.0","IEC 60079-15:2017 ed. 5.0","PN-EN 60079-18:2011","EN 60079-18:2009","IEC 60079-18:2009+AC1:2009 ed.3.0","PN-EN 60079-18:2015-06","EN 60079-18:2015,","IEC 60079-18:2014 ed. 4.0 EC 60079-18:2014+AMD1:2017 CSV ed.4.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Parametry elektryczne: napięcie, prąd, moc, indukcyjność, pojemność, rezystancja, wytrzymałość elektryczna – pomiary bezpośrednie PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN 60079-7:2010 | EN 60079-7:2007 | IEC 60079-7:2006 ed.4.0 | PN-EN 60079-7:2016-02 | EN 60079-7:2015, | IEC 60079-7:2015 ed.5.0 | IEC 60079-7:2015+AMD1:2017 CSV ed.5.1 | PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0 | PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0 | PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014 ed. 4.0 EC 60079-18:2014+AMD1:2017 CSV ed.4.1 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Parametry elektryczne: napiecie, prad, moc, indukcyjnosc, pojemnosc, rezystancja, wytrzymalosc elektryczna – pomiary bezposrednie PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN 60079-7:2010 | EN 60079-7:2007 | IEC 60079-7:2006 ed.4.0 | PN-EN 60079-7:2016-02 | EN 60079-7:2015, | IEC 60079-7:2015 ed.5.0 | IEC 60079-7:2015+AMD1:2017 CSV ed.5.1 | PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0 | PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0 | PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014 ed. 4.0 EC 60079-18:2014+AMD1:2017 CSV ed.4.1","categories":["other"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Electrical parameters: voltage, current, power, inductance, capacitance, resistance, electric strength – direct measurements PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN 60079-7:2010 | EN 60079-7:2007 | IEC 60079-7:2006 ed.4.0 | PN-EN 60079-7:2016-02 | EN 60079-7:2015, | IEC 60079-7:2015 ed.5.0 | IEC 60079-7:2015+AMD1:2017 CSV ed.5.1 | PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0 | PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0 | PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014 ed. 4.0 EC 60079-18:2014+AMD1:2017 CSV ed.4.1","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN 60079-7:2010 | EN 60079-7:2007 | IEC 60079-7:2006 ed.4.0 | PN-EN 60079-7:2016-02 | EN 60079-7:2015, | IEC 60079-7:2015 ed.5.0 | IEC 60079-7:2015+AMD1:2017 CSV ed.5.1 | PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0 | PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0 | PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014 ed. 4.0 EC 60079-18:2014+AMD1:2017 CSV ed.4.1","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259afd","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Szczelność konstrukcji oraz elementów spajanych i uszczelnionych spoiwem - działanie ciśnieniem statycznym w zakresie od 25 Pa do 3 MPa","methodology_en":"Tightness of structures and of elements joined and sealed with adhesive - static pressure application in the range from 25 Pa to 3 MPa","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność konstrukcji oraz elementów spajanych i uszczelnionych spoiwem - działanie ciśnieniem statycznym w zakresie od 25 Pa do 3 MPa","reference":"PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN ISO 80079-37:2016-07 | EN ISO 80079-37:2016 | ISO 80079-37:2016 | PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016 | PN-EN 60079-2:2010 | EN 60079-2:2007 | IEC 60079-2:2007 ed.5.0 | PN-EN 60079-2:2015-02 | EN 60079-2:2014 | IEC 60079-2:2014 ed.6.0","norm_bases":["PN-EN 60079-1:2010","EN 60079-1:2007","IEC 60079-1:2007 ed.6.0","PN-EN 60079-1:2014-12","EN 60079-1:2014","IEC 60079-1:2014 ed.7.0","PN-EN ISO 80079-37:2016-07","EN ISO 80079-37:2016","ISO 80079-37:2016","PN-EN ISO 16852:2012","EN ISO 16852:2010","PN-EN ISO 16852:2017-02","EN ISO 16852:2016","ISO 16852:2016","PN-EN 60079-2:2010","EN 60079-2:2007","IEC 60079-2:2007 ed.5.0","PN-EN 60079-2:2015-02","EN 60079-2:2014","IEC 60079-2:2014 ed.6.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Szczelność konstrukcji oraz elementów spajanych i uszczelnionych spoiwem - działanie ciśnieniem statycznym w zakresie od 25 Pa do 3 MPa PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN ISO 80079-37:2016-07 | EN ISO 80079-37:2016 | ISO 80079-37:2016 | PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016 | PN-EN 60079-2:2010 | EN 60079-2:2007 | IEC 60079-2:2007 ed.5.0 | PN-EN 60079-2:2015-02 | EN 60079-2:2014 | IEC 60079-2:2014 ed.6.0 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Szczelnosc konstrukcji oraz elementow spajanych i uszczelnionych spoiwem - dzialanie cisnieniem statycznym w zakresie od 25 Pa do 3 MPa PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN ISO 80079-37:2016-07 | EN ISO 80079-37:2016 | ISO 80079-37:2016 | PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016 | PN-EN 60079-2:2010 | EN 60079-2:2007 | IEC 60079-2:2007 ed.5.0 | PN-EN 60079-2:2015-02 | EN 60079-2:2014 | IEC 60079-2:2014 ed.6.0","categories":["other"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Tightness of structures and of elements joined and sealed with adhesive - static pressure application in the range from 25 Pa to 3 MPa PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN ISO 80079-37:2016-07 | EN ISO 80079-37:2016 | ISO 80079-37:2016 | PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016 | PN-EN 60079-2:2010 | EN 60079-2:2007 | IEC 60079-2:2007 ed.5.0 | PN-EN 60079-2:2015-02 | EN 60079-2:2014 | IEC 60079-2:2014 ed.6.0","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN ISO 80079-37:2016-07 | EN ISO 80079-37:2016 | ISO 80079-37:2016 | PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016 | PN-EN 60079-2:2010 | EN 60079-2:2007 | IEC 60079-2:2007 ed.5.0 | PN-EN 60079-2:2015-02 | EN 60079-2:2014 | IEC 60079-2:2014 ed.6.0","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259afe","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Szczelność i wytrzymałość wpustów kablowych – działanie ciśnieniem statycznym w zakresie od 100 Pa do 3 MPa","methodology_en":"Tightness and strength of cable glands – static pressure application in the range from 100 Pa to 3 MPa","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność i wytrzymałość wpustów kablowych – działanie ciśnieniem statycznym w zakresie od 100 Pa do 3 MPa","reference":"PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","norm_bases":["PN-EN 60079-1:2010","EN 60079-1:2007","IEC 60079-1:2007 ed.6.0","PN-EN 60079-1:2014-12","EN 60079-1:2014","IEC 60079-1:2014 ed.7.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Szczelność i wytrzymałość wpustów kablowych – działanie ciśnieniem statycznym w zakresie od 100 Pa do 3 MPa PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Szczelnosc i wytrzymalosc wpustow kablowych – dzialanie cisnieniem statycznym w zakresie od 100 Pa do 3 MPa PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","categories":["other"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Tightness and strength of cable glands – static pressure application in the range from 100 Pa to 3 MPa PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259aff","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Skuteczność zadławienia przewodu we wpuście – bezpośrednie przyłożenie siły w zakresie od 1 N do 5000 N","methodology_en":"Effectiveness of cable clamping in the entry – direct application of force in the range from 1 N to 5000 N","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność zadławienia przewodu we wpuście – bezpośrednie przyłożenie siły w zakresie od 1 N do 5000 N","reference":"PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","norm_bases":["PN-EN 60079-0:2013-03","EN 60079-0:2012","IEC 60079-0:2011 ed.6.0","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012/A11:2013","IEC 60079-0:2017 ed.7.0","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017","PN-EN 60079-1:2010","EN 60079-1:2007","IEC 60079-1:2007 ed.6.0","PN-EN 60079-1:2014-12","EN 60079-1:2014","IEC 60079-1:2014 ed.7.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Skuteczność zadławienia przewodu we wpuście – bezpośrednie przyłożenie siły w zakresie od 1 N do 5000 N PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Skutecznosc zadlawienia przewodu we wpuscie – bezposrednie przylozenie sily w zakresie od 1 N do 5000 N PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","categories":["other"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Effectiveness of cable clamping in the entry – direct application of force in the range from 1 N to 5000 N PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259b00","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Parametry ciśnienia wybuchu mieszanin gazów i par cieczy palnych – pomiar bezpośredni i rejestracja ciśnienia dynamicznego w zakresie od 0,05 MPa do 20 MPa","methodology_en":"Explosion pressure parameters of mixtures of gases and vapours of flammable liquids – direct measurement and recording of dynamic pressure in the range from 0,05 MPa to 20 MPa","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Parametry ciśnienia wybuchu mieszanin gazów i par cieczy palnych – pomiar bezpośredni i rejestracja ciśnienia dynamicznego w zakresie od 0,05 MPa do 20 MPa","reference":"PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN 13463-3:2006 | EN 13463-3:2005 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000","norm_bases":["PN-EN 60079-1:2010","EN 60079-1:2007","IEC 60079-1:2007 ed.6.0","PN-EN 60079-1:2014-12","EN 60079-1:2014","IEC 60079-1:2014 ed.7.0","PN-EN 13463-3:2006","EN 13463-3:2005","PN-EN 1834-1:2002","EN 1834-1:2000","PN-EN 1834-2:2002","EN 1834-2:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Parametry ciśnienia wybuchu mieszanin gazów i par cieczy palnych – pomiar bezpośredni i rejestracja ciśnienia dynamicznego w zakresie od 0,05 MPa do 20 MPa PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN 13463-3:2006 | EN 13463-3:2005 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Parametry cisnienia wybuchu mieszanin gazow i par cieczy palnych – pomiar bezposredni i rejestracja cisnienia dynamicznego w zakresie od 0,05 MPa do 20 MPa PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN 13463-3:2006 | EN 13463-3:2005 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000","categories":["other"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Explosion pressure parameters of mixtures of gases and vapours of flammable liquids – direct measurement and recording of dynamic pressure in the range from 0,05 MPa to 20 MPa PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN 13463-3:2006 | EN 13463-3:2005 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN 13463-3:2006 | EN 13463-3:2005 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259b01","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Wytrzymałość osłon i konstrukcji na działanie ciśnienia dynamicznego – bezpośrednie działanie ciśnieniem dynamicznym w zakresie od 0,05 MPa do 10 MPa","methodology_en":"Strength of guards and structures under dynamic pressure – direct application of dynamic pressure in the range from 0,05 MPa to 10 MPa","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość osłon i konstrukcji na działanie ciśnienia dynamicznego – bezpośrednie działanie ciśnieniem dynamicznym w zakresie od 0,05 MPa do 10 MPa","reference":"PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN 13463-3:2006 | EN 13463-3:2005 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000 | EN 14986:2007 | PN-EN 14986:2009 | PN-EN 14986:2017-02 | EN 14986:2017","norm_bases":["PN-EN 60079-1:2010","EN 60079-1:2007","IEC 60079-1:2007 ed.6.0","PN-EN 60079-1:2014-12","EN 60079-1:2014","IEC 60079-1:2014 ed.7.0","PN-EN 13463-3:2006","EN 13463-3:2005","PN-EN 1834-1:2002","EN 1834-1:2000","PN-EN 1834-2:2002","EN 1834-2:2000","EN 14986:2007","PN-EN 14986:2009","PN-EN 14986:2017-02","EN 14986:2017"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Wytrzymałość osłon i konstrukcji na działanie ciśnienia dynamicznego – bezpośrednie działanie ciśnieniem dynamicznym w zakresie od 0,05 MPa do 10 MPa PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN 13463-3:2006 | EN 13463-3:2005 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000 | EN 14986:2007 | PN-EN 14986:2009 | PN-EN 14986:2017-02 | EN 14986:2017 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Wytrzymalosc oslon i konstrukcji na dzialanie cisnienia dynamicznego – bezposrednie dzialanie cisnieniem dynamicznym w zakresie od 0,05 MPa do 10 MPa PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN 13463-3:2006 | EN 13463-3:2005 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000 | EN 14986:2007 | PN-EN 14986:2009 | PN-EN 14986:2017-02 | EN 14986:2017","categories":["other"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Strength of guards and structures under dynamic pressure – direct application of dynamic pressure in the range from 0,05 MPa to 10 MPa PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN 13463-3:2006 | EN 13463-3:2005 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000 | EN 14986:2007 | PN-EN 14986:2009 | PN-EN 14986:2017-02 | EN 14986:2017","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN 13463-3:2006 | EN 13463-3:2005 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000 | EN 14986:2007 | PN-EN 14986:2009 | PN-EN 14986:2017-02 | EN 14986:2017","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259b02","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Nieprzenoszenie się z wnętrza osłony wewnętrznego wybuchu mieszanin gazów i par cieczy palnych – badanie bezpośrednie w mieszaninie gazowej","methodology_en":"Non-transmission of an internal explosion of flammable gas and vapour mixtures from inside the enclosure – direct test in a gas mixture","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Nieprzenoszenie się z wnętrza osłony wewnętrznego wybuchu mieszanin gazów i par cieczy palnych – badanie bezpośrednie w mieszaninie gazowej","reference":"PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN 13463-3:2006 | EN 13463-3:2005 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000 | EN 14986:2007 | PN-EN 14986:2009 | PN-EN 14986:2017-02 | EN 14986:2017","norm_bases":["PN-EN 60079-1:2010","EN 60079-1:2007","IEC 60079-1:2007 ed.6.0","PN-EN 60079-1:2014-12","EN 60079-1:2014","IEC 60079-1:2014 ed.7.0","PN-EN 13463-3:2006","EN 13463-3:2005","PN-EN 1834-1:2002","EN 1834-1:2000","PN-EN 1834-2:2002","EN 1834-2:2000","EN 14986:2007","PN-EN 14986:2009","PN-EN 14986:2017-02","EN 14986:2017"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Nieprzenoszenie się z wnętrza osłony wewnętrznego wybuchu mieszanin gazów i par cieczy palnych – badanie bezpośrednie w mieszaninie gazowej PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN 13463-3:2006 | EN 13463-3:2005 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000 | EN 14986:2007 | PN-EN 14986:2009 | PN-EN 14986:2017-02 | EN 14986:2017 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Nieprzenoszenie sie z wnetrza oslony wewnetrznego wybuchu mieszanin gazow i par cieczy palnych – badanie bezposrednie w mieszaninie gazowej PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN 13463-3:2006 | EN 13463-3:2005 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000 | EN 14986:2007 | PN-EN 14986:2009 | PN-EN 14986:2017-02 | EN 14986:2017","categories":["other"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Non-transmission of an internal explosion of flammable gas and vapour mixtures from inside the enclosure – direct test in a gas mixture PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN 13463-3:2006 | EN 13463-3:2005 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000 | EN 14986:2007 | PN-EN 14986:2009 | PN-EN 14986:2017-02 | EN 14986:2017","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 | PN-EN 13463-3:2006 | EN 13463-3:2005 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000 | EN 14986:2007 | PN-EN 14986:2009 | PN-EN 14986:2017-02 | EN 14986:2017","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259b03","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Wytrzymałość mechaniczna osłon i konstrukcji – działanie ciśnieniem statycznym w zakresie od 25 Pa do 3, MPa","methodology_en":"Mechanical strength of enclosures and structures – static pressure action in the range from 25 Pa to 3, MPa","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna osłon i konstrukcji – działanie ciśnieniem statycznym w zakresie od 25 Pa do 3, MPa","reference":"PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","norm_bases":["PN-EN 60079-1:2010","EN 60079-1:2007","IEC 60079-1:2007 ed.6.0","PN-EN 60079-1:2014-12","EN 60079-1:2014","IEC 60079-1:2014 ed.7.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Wytrzymałość mechaniczna osłon i konstrukcji – działanie ciśnieniem statycznym w zakresie od 25 Pa do 3, MPa PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Wytrzymalosc mechaniczna oslon i konstrukcji – dzialanie cisnieniem statycznym w zakresie od 25 Pa do 3, MPa PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","categories":["other"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Mechanical strength of enclosures and structures – static pressure action in the range from 25 Pa to 3, MPa PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259b04","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Wytrzymałość mechaniczna osłon i konstrukcji – działanie ciśnieniem statycznym w zakresie od 25 Pa do 3, MPa","methodology_en":"Mechanical strength of enclosures and structures – static pressure action in the range from 25 Pa to 3, MPa","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna osłon i konstrukcji – działanie ciśnieniem statycznym w zakresie od 25 Pa do 3, MPa","reference":"PN-EN 60079-2:2010 | EN 60079-2:2007 | IEC 60079-2:2007ed. 5.0 | PN-EN 60079-2:2015-02 | EN 60079-2:2014 | IEC 60079-2:2014 ed.6.0 | PN-EN 60079-5:2010 | EN 60079-5:2007 | IEC 60079-5:2007 ed.3.0 | PN-EN 60079-5:2015-08 | EN 60079-5:2015 | IEC 60079-5:2015 ed.4.0 | PN-EN 60079-6:2010 | EN 60079-6:2007 | IEC 60079-6:2007 ed.3.0 | PN-EN 60079-6:2016-02 | EN 60079-6:2015 | IEC 60079-6:2015 ed. 4.0 | PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014-12 ed. 4.0 | IEC 60079-18:2014+AMD1:2017 CSV ed.4.1 | PN-EN 13463-3:2006 | EN 13463-3:2005 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000 | EN 14986:2007 | PN-EN 14986:2009 | PN-EN 14986:2017-02 | EN 14986:2017","norm_bases":["PN-EN 60079-2:2010","EN 60079-2:2007","IEC 60079-2:2007ed. 5.0","PN-EN 60079-2:2015-02","EN 60079-2:2014","IEC 60079-2:2014 ed.6.0","PN-EN 60079-5:2010","EN 60079-5:2007","IEC 60079-5:2007 ed.3.0","PN-EN 60079-5:2015-08","EN 60079-5:2015","IEC 60079-5:2015 ed.4.0","PN-EN 60079-6:2010","EN 60079-6:2007","IEC 60079-6:2007 ed.3.0","PN-EN 60079-6:2016-02","EN 60079-6:2015","IEC 60079-6:2015 ed. 4.0","PN-EN 60079-18:2011","EN 60079-18:2009","IEC 60079-18:2009+AC1:2009 ed.3.0","PN-EN 60079-18:2015-06","EN 60079-18:2015,","IEC 60079-18:2014-12 ed. 4.0","IEC 60079-18:2014+AMD1:2017 CSV ed.4.1","PN-EN 13463-3:2006","EN 13463-3:2005","PN-EN 1834-1:2002","EN 1834-1:2000","PN-EN 1834-2:2002","EN 1834-2:2000","EN 14986:2007","PN-EN 14986:2009","PN-EN 14986:2017-02","EN 14986:2017"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Wytrzymałość mechaniczna osłon i konstrukcji – działanie ciśnieniem statycznym w zakresie od 25 Pa do 3, MPa PN-EN 60079-2:2010 | EN 60079-2:2007 | IEC 60079-2:2007ed. 5.0 | PN-EN 60079-2:2015-02 | EN 60079-2:2014 | IEC 60079-2:2014 ed.6.0 | PN-EN 60079-5:2010 | EN 60079-5:2007 | IEC 60079-5:2007 ed.3.0 | PN-EN 60079-5:2015-08 | EN 60079-5:2015 | IEC 60079-5:2015 ed.4.0 | PN-EN 60079-6:2010 | EN 60079-6:2007 | IEC 60079-6:2007 ed.3.0 | PN-EN 60079-6:2016-02 | EN 60079-6:2015 | IEC 60079-6:2015 ed. 4.0 | PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014-12 ed. 4.0 | IEC 60079-18:2014+AMD1:2017 CSV ed.4.1 | PN-EN 13463-3:2006 | EN 13463-3:2005 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000 | EN 14986:2007 | PN-EN 14986:2009 | PN-EN 14986:2017-02 | EN 14986:2017 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Wytrzymalosc mechaniczna oslon i konstrukcji – dzialanie cisnieniem statycznym w zakresie od 25 Pa do 3, MPa PN-EN 60079-2:2010 | EN 60079-2:2007 | IEC 60079-2:2007ed. 5.0 | PN-EN 60079-2:2015-02 | EN 60079-2:2014 | IEC 60079-2:2014 ed.6.0 | PN-EN 60079-5:2010 | EN 60079-5:2007 | IEC 60079-5:2007 ed.3.0 | PN-EN 60079-5:2015-08 | EN 60079-5:2015 | IEC 60079-5:2015 ed.4.0 | PN-EN 60079-6:2010 | EN 60079-6:2007 | IEC 60079-6:2007 ed.3.0 | PN-EN 60079-6:2016-02 | EN 60079-6:2015 | IEC 60079-6:2015 ed. 4.0 | PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014-12 ed. 4.0 | IEC 60079-18:2014+AMD1:2017 CSV ed.4.1 | PN-EN 13463-3:2006 | EN 13463-3:2005 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000 | EN 14986:2007 | PN-EN 14986:2009 | PN-EN 14986:2017-02 | EN 14986:2017","categories":["other"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Mechanical strength of enclosures and structures – static pressure action in the range from 25 Pa to 3, MPa PN-EN 60079-2:2010 | EN 60079-2:2007 | IEC 60079-2:2007ed. 5.0 | PN-EN 60079-2:2015-02 | EN 60079-2:2014 | IEC 60079-2:2014 ed.6.0 | PN-EN 60079-5:2010 | EN 60079-5:2007 | IEC 60079-5:2007 ed.3.0 | PN-EN 60079-5:2015-08 | EN 60079-5:2015 | IEC 60079-5:2015 ed.4.0 | PN-EN 60079-6:2010 | EN 60079-6:2007 | IEC 60079-6:2007 ed.3.0 | PN-EN 60079-6:2016-02 | EN 60079-6:2015 | IEC 60079-6:2015 ed. 4.0 | PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014-12 ed. 4.0 | IEC 60079-18:2014+AMD1:2017 CSV ed.4.1 | PN-EN 13463-3:2006 | EN 13463-3:2005 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000 | EN 14986:2007 | PN-EN 14986:2009 | PN-EN 14986:2017-02 | EN 14986:2017","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-2:2010 | EN 60079-2:2007 | IEC 60079-2:2007ed. 5.0 | PN-EN 60079-2:2015-02 | EN 60079-2:2014 | IEC 60079-2:2014 ed.6.0 | PN-EN 60079-5:2010 | EN 60079-5:2007 | IEC 60079-5:2007 ed.3.0 | PN-EN 60079-5:2015-08 | EN 60079-5:2015 | IEC 60079-5:2015 ed.4.0 | PN-EN 60079-6:2010 | EN 60079-6:2007 | IEC 60079-6:2007 ed.3.0 | PN-EN 60079-6:2016-02 | EN 60079-6:2015 | IEC 60079-6:2015 ed. 4.0 | PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014-12 ed. 4.0 | IEC 60079-18:2014+AMD1:2017 CSV ed.4.1 | PN-EN 13463-3:2006 | EN 13463-3:2005 | PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000 | EN 14986:2007 | PN-EN 14986:2009 | PN-EN 14986:2017-02 | EN 14986:2017","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259b05","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Erozja spowodowana wewnętrznym wybuchem mieszanin gazów i par cieczy palnych – badanie bezpośrednie w mieszaninie gazowej","methodology_en":"Erosion caused by internal explosion of mixtures of gases and vapours of flammable liquids – direct test in a gas mixture","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Erozja spowodowana wewnętrznym wybuchem mieszanin gazów i par cieczy palnych – badanie bezpośrednie w mieszaninie gazowej","reference":"PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","norm_bases":["PN-EN 60079-1:2010","EN 60079-1:2007","IEC 60079-1:2007 ed.6.0","PN-EN 60079-1:2014-12","EN 60079-1:2014","IEC 60079-1:2014 ed.7.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Erozja spowodowana wewnętrznym wybuchem mieszanin gazów i par cieczy palnych – badanie bezpośrednie w mieszaninie gazowej PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Erozja spowodowana wewnetrznym wybuchem mieszanin gazow i par cieczy palnych – badanie bezposrednie w mieszaninie gazowej PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","categories":["other"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Erosion caused by internal explosion of mixtures of gases and vapours of flammable liquids – direct test in a gas mixture PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259b06","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Szczelność wypełnionych masą elementów zatrzymujących płomień – działanie ciśnieniem statycznym w zakresie od 0,05 MPa do 3 MPa","methodology_en":"Tightness of compound-filled flame arresting elements – static pressure application in the range from 0,05 MPa to 3 MPa","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność wypełnionych masą elementów zatrzymujących płomień – działanie ciśnieniem statycznym w zakresie od 0,05 MPa do 3 MPa","reference":"PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","norm_bases":["PN-EN 60079-1:2010","EN 60079-1:2007","IEC 60079-1:2007 ed.6.0","PN-EN 60079-1:2014-12","EN 60079-1:2014","IEC 60079-1:2014 ed.7.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Szczelność wypełnionych masą elementów zatrzymujących płomień – działanie ciśnieniem statycznym w zakresie od 0,05 MPa do 3 MPa PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Szczelnosc wypelnionych masa elementow zatrzymujacych plomien – dzialanie cisnieniem statycznym w zakresie od 0,05 MPa do 3 MPa PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","categories":["other"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Tightness of compound-filled flame arresting elements – static pressure application in the range from 0,05 MPa to 3 MPa PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259b07","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym","test_object_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components","methodology":"Skuteczność działania elementów oddechowych i odwadniania – badanie bezpośrednie w mieszaninie gazowej","methodology_en":"Operational effectiveness of breather and drainage elements – direct test in a gas mixture","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność działania elementów oddechowych i odwadniania – badanie bezpośrednie w mieszaninie gazowej","reference":"PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","norm_bases":["PN-EN 60079-1:2010","EN 60079-1:2007","IEC 60079-1:2007 ed.6.0","PN-EN 60079-1:2014-12","EN 60079-1:2014","IEC 60079-1:2014 ed.7.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia i obudowy oraz podzespoły urządzeń elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Skuteczność działania elementów oddechowych i odwadniania – badanie bezpośrednie w mieszaninie gazowej PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0 Urzadzenia i obudowy oraz podzespoly urzadzen elektrycznych i nieelektrycznych w wykonaniu przeciwwybuchowym Skutecznosc dzialania elementow oddechowych i odwadniania – badanie bezposrednie w mieszaninie gazowej PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","categories":["other"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected electrical and non-electrical equipment, enclosures and components Operational effectiveness of breather and drainage elements – direct test in a gas mixture PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","search_zh":"防爆型电气与非电气设备、外壳及部件 PN-EN 60079-1:2010 | EN 60079-1:2007 | IEC 60079-1:2007 ed.6.0 | PN-EN 60079-1:2014-12 | EN 60079-1:2014 | IEC 60079-1:2014 ed.7.0","test_object_zh":"防爆型电气与非电气设备、外壳及部件"},{"_id":"6a5dc9a7f1c10c8ce8259b08","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Lampy nahełmne do użytku w zakładach górniczych zagrożonych wybuchem gazu kopalnianego (metanu)","test_object_en":"Cap lamps for use in mines endangered by firedamp (methane) explosion","methodology":"Zdolność zapalania mieszaniny gazów i par cieczy palnych przez bezpiecznik topikowy – metoda bezpośrednia","methodology_en":"Ability of a fuse-link to ignite a mixture of gases and vapours of flammable liquids – direct method","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność zapalania mieszaniny gazów i par cieczy palnych przez bezpiecznik topikowy – metoda bezpośrednia","reference":"PN-EN 60079-35-1:2011 | EN 60079-35-1:2011","norm_bases":["PN-EN 60079-35-1:2011","EN 60079-35-1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Lampy nahełmne do użytku w zakładach górniczych zagrożonych wybuchem gazu kopalnianego (metanu) Zdolność zapalania mieszaniny gazów i par cieczy palnych przez bezpiecznik topikowy – metoda bezpośrednia PN-EN 60079-35-1:2011 | EN 60079-35-1:2011 Lampy nahelmne do uzytku w zakladach gorniczych zagrozonych wybuchem gazu kopalnianego (metanu) Zdolnosc zapalania mieszaniny gazow i par cieczy palnych przez bezpiecznik topikowy – metoda bezposrednia PN-EN 60079-35-1:2011 | EN 60079-35-1:2011","categories":["other"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cap lamps for use in mines endangered by firedamp (methane) explosion Ability of a fuse-link to ignite a mixture of gases and vapours of flammable liquids – direct method PN-EN 60079-35-1:2011 | EN 60079-35-1:2011","search_zh":"有矿井瓦斯（甲烷）爆炸危险的矿山用矿帽灯 PN-EN 60079-35-1:2011 | EN 60079-35-1:2011","test_object_zh":"有矿井瓦斯（甲烷）爆炸危险的矿山用矿帽灯"},{"_id":"6a5dc9a7f1c10c8ce8259b09","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Lampy nahełmne do użytku w zakładach górniczych zagrożonych wybuchem gazu kopalnianego (metanu)","test_object_en":"Cap lamps for use in mines endangered by firedamp (methane) explosion","methodology":"Zdolność zapalania termicznego mieszaniny gazów i par cieczy palnych przez jeden drut żyły przewodu – metoda bezpośrednia","methodology_en":"Ability of a single wire of a conductor core to thermally ignite a mixture of gases and vapours of flammable liquids – direct method","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność zapalania termicznego mieszaniny gazów i par cieczy palnych przez jeden drut żyły przewodu – metoda bezpośrednia","reference":"PN-EN 60079-35-1:2011 | EN 60079-35-1:2011","norm_bases":["PN-EN 60079-35-1:2011","EN 60079-35-1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Lampy nahełmne do użytku w zakładach górniczych zagrożonych wybuchem gazu kopalnianego (metanu) Zdolność zapalania termicznego mieszaniny gazów i par cieczy palnych przez jeden drut żyły przewodu – metoda bezpośrednia PN-EN 60079-35-1:2011 | EN 60079-35-1:2011 Lampy nahelmne do uzytku w zakladach gorniczych zagrozonych wybuchem gazu kopalnianego (metanu) Zdolnosc zapalania termicznego mieszaniny gazow i par cieczy palnych przez jeden drut zyly przewodu – metoda bezposrednia PN-EN 60079-35-1:2011 | EN 60079-35-1:2011","categories":["other"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cap lamps for use in mines endangered by firedamp (methane) explosion Ability of a single wire of a conductor core to thermally ignite a mixture of gases and vapours of flammable liquids – direct method PN-EN 60079-35-1:2011 | EN 60079-35-1:2011","search_zh":"有矿井瓦斯（甲烷）爆炸危险的矿山用矿帽灯 PN-EN 60079-35-1:2011 | EN 60079-35-1:2011","test_object_zh":"有矿井瓦斯（甲烷）爆炸危险的矿山用矿帽灯"},{"_id":"6a5dc9a7f1c10c8ce8259b0a","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Lampy nahełmne do użytku w zakładach górniczych zagrożonych wybuchem gazu kopalnianego (metanu)","test_object_en":"Cap lamps for use in mines endangered by firedamp (methane) explosion","methodology":"Odporność powłoki przewodu na kwasy tłuszczowe – metoda bezpośrednia w kwasach","methodology_en":"Resistance of the cable sheath to fatty acids – direct method in acids","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność powłoki przewodu na kwasy tłuszczowe – metoda bezpośrednia w kwasach","reference":"PN-EN 60079-35-1:2011 | EN 60079-35-1:2011","norm_bases":["PN-EN 60079-35-1:2011","EN 60079-35-1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Lampy nahełmne do użytku w zakładach górniczych zagrożonych wybuchem gazu kopalnianego (metanu) Odporność powłoki przewodu na kwasy tłuszczowe – metoda bezpośrednia w kwasach PN-EN 60079-35-1:2011 | EN 60079-35-1:2011 Lampy nahelmne do uzytku w zakladach gorniczych zagrozonych wybuchem gazu kopalnianego (metanu) Odpornosc powloki przewodu na kwasy tluszczowe – metoda bezposrednia w kwasach PN-EN 60079-35-1:2011 | EN 60079-35-1:2011","categories":["other"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cap lamps for use in mines endangered by firedamp (methane) explosion Resistance of the cable sheath to fatty acids – direct method in acids PN-EN 60079-35-1:2011 | EN 60079-35-1:2011","search_zh":"有矿井瓦斯（甲烷）爆炸危险的矿山用矿帽灯 PN-EN 60079-35-1:2011 | EN 60079-35-1:2011","test_object_zh":"有矿井瓦斯（甲烷）爆炸危险的矿山用矿帽灯"},{"_id":"6a5dc9a7f1c10c8ce8259b0b","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Lampy nahełmne do użytku w zakładach górniczych zagrożonych wybuchem gazu kopalnianego (metanu)","test_object_en":"Cap lamps for use in mines endangered by firedamp (methane) explosion","methodology":"Odporność na wyciek elektrolitu ogniw – metoda bezpośrednia","methodology_en":"Resistance to cell electrolyte leakage – direct method","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wyciek elektrolitu ogniw – metoda bezpośrednia","reference":"PN-EN 60079-35-1:2011 | EN 60079-35-1:2011","norm_bases":["PN-EN 60079-35-1:2011","EN 60079-35-1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Lampy nahełmne do użytku w zakładach górniczych zagrożonych wybuchem gazu kopalnianego (metanu) Odporność na wyciek elektrolitu ogniw – metoda bezpośrednia PN-EN 60079-35-1:2011 | EN 60079-35-1:2011 Lampy nahelmne do uzytku w zakladach gorniczych zagrozonych wybuchem gazu kopalnianego (metanu) Odpornosc na wyciek elektrolitu ogniw – metoda bezposrednia PN-EN 60079-35-1:2011 | EN 60079-35-1:2011","categories":["other"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cap lamps for use in mines endangered by firedamp (methane) explosion Resistance to cell electrolyte leakage – direct method PN-EN 60079-35-1:2011 | EN 60079-35-1:2011","search_zh":"有矿井瓦斯（甲烷）爆炸危险的矿山用矿帽灯 PN-EN 60079-35-1:2011 | EN 60079-35-1:2011","test_object_zh":"有矿井瓦斯（甲烷）爆炸危险的矿山用矿帽灯"},{"_id":"6a5dc9a7f1c10c8ce8259b0c","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Przerywacze płomienia","test_object_en":"Flame arresters","methodology":"Przepływ powietrza – metoda bezpośrednia; natężenie przepływu w zakresie od 0,005 m3/min do 5 m3/min","methodology_en":"Air flow – direct method; flow rate in the range from 0,005 m3/min to 5 m3/min","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepływ powietrza – metoda bezpośrednia; natężenie przepływu w zakresie od 0,005 m3/min do 5 m3/min","reference":"PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","norm_bases":["PN-EN ISO 16852:2012","EN ISO 16852:2010","PN-EN ISO 16852:2017-02","EN ISO 16852:2016","ISO 16852:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przerywacze płomienia Przepływ powietrza – metoda bezpośrednia; natężenie przepływu w zakresie od 0,005 m3/min do 5 m3/min PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016 Przerywacze plomienia Przeplyw powietrza – metoda bezposrednia; natezenie przeplywu w zakresie od 0,005 m3/min do 5 m3/min PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","categories":["other"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Flame arresters Air flow – direct method; flow rate in the range from 0,005 m3/min to 5 m3/min PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","search_zh":"阻火器 PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","test_object_zh":"阻火器"},{"_id":"6a5dc9a7f1c10c8ce8259b0d","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Przerywacze płomienia","test_object_en":"Flame arresters","methodology":"Przenoszenie płomienia końcowego przerywacza płomienia, w warunkach deflagracji – metoda bezpośrednia w mieszaninie gazowej","methodology_en":"Flame transmission of an end-of-line flame arrester, under deflagration conditions – direct method in a gas mixture","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Przenoszenie płomienia końcowego przerywacza płomienia, w warunkach deflagracji – metoda bezpośrednia w mieszaninie gazowej","reference":"PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","norm_bases":["PN-EN ISO 16852:2012","EN ISO 16852:2010","PN-EN ISO 16852:2017-02","EN ISO 16852:2016","ISO 16852:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przerywacze płomienia Przenoszenie płomienia końcowego przerywacza płomienia, w warunkach deflagracji – metoda bezpośrednia w mieszaninie gazowej PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016 Przerywacze plomienia Przenoszenie plomienia koncowego przerywacza plomienia, w warunkach deflagracji – metoda bezposrednia w mieszaninie gazowej PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","categories":["other"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Flame arresters Flame transmission of an end-of-line flame arrester, under deflagration conditions – direct method in a gas mixture PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","search_zh":"阻火器 PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","test_object_zh":"阻火器"},{"_id":"6a5dc9a7f1c10c8ce8259b0e","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Przerywacze płomienia","test_object_en":"Flame arresters","methodology":"Przenoszenie płomienia rurowego przerywacza płomienia, w warunkach deflagracji – metoda bezpośrednia w mieszaninie gazowej","methodology_en":"Flame transmission of an in-line flame arrester, under deflagration conditions – direct method in a gas mixture","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Przenoszenie płomienia rurowego przerywacza płomienia, w warunkach deflagracji – metoda bezpośrednia w mieszaninie gazowej","reference":"PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","norm_bases":["PN-EN ISO 16852:2012","EN ISO 16852:2010","PN-EN ISO 16852:2017-02","EN ISO 16852:2016","ISO 16852:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przerywacze płomienia Przenoszenie płomienia rurowego przerywacza płomienia, w warunkach deflagracji – metoda bezpośrednia w mieszaninie gazowej PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016 Przerywacze plomienia Przenoszenie plomienia rurowego przerywacza plomienia, w warunkach deflagracji – metoda bezposrednia w mieszaninie gazowej PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","categories":["other"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Flame arresters Flame transmission of an in-line flame arrester, under deflagration conditions – direct method in a gas mixture PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","search_zh":"阻火器 PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","test_object_zh":"阻火器"},{"_id":"6a5dc9a7f1c10c8ce8259b0f","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Przerywacze płomienia","test_object_en":"Flame arresters","methodology":"Przenoszenie płomienia przerywacza płomienia wybuchu objętościowego, w warunkach deflagracji – metoda bezpośrednia w mieszaninie gazowej","methodology_en":"Flame transmission of a volume explosion flame arrester, under deflagration conditions – direct method in a gas mixture","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Przenoszenie płomienia przerywacza płomienia wybuchu objętościowego, w warunkach deflagracji – metoda bezpośrednia w mieszaninie gazowej","reference":"PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","norm_bases":["PN-EN ISO 16852:2012","EN ISO 16852:2010","PN-EN ISO 16852:2017-02","EN ISO 16852:2016","ISO 16852:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przerywacze płomienia Przenoszenie płomienia przerywacza płomienia wybuchu objętościowego, w warunkach deflagracji – metoda bezpośrednia w mieszaninie gazowej PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016 Przerywacze plomienia Przenoszenie plomienia przerywacza plomienia wybuchu objetosciowego, w warunkach deflagracji – metoda bezposrednia w mieszaninie gazowej PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","categories":["other"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Flame arresters Flame transmission of a volume explosion flame arrester, under deflagration conditions – direct method in a gas mixture PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","search_zh":"阻火器 PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","test_object_zh":"阻火器"},{"_id":"6a5dc9a7f1c10c8ce8259b10","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Przerywacze płomienia","test_object_en":"Flame arresters","methodology":"Przenoszenie płomienia rurowego przerywacza płomienia, w warunkach detonacji stabilnej bez restrykcji – metoda bezpośrednia w mieszaninie gazowej","methodology_en":"Flame transmission of an in-line flame arrester, under stable detonation conditions without restriction – direct method in a gas mixture","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Przenoszenie płomienia rurowego przerywacza płomienia, w warunkach detonacji stabilnej bez restrykcji – metoda bezpośrednia w mieszaninie gazowej","reference":"PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","norm_bases":["PN-EN ISO 16852:2012","EN ISO 16852:2010","PN-EN ISO 16852:2017-02","EN ISO 16852:2016","ISO 16852:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przerywacze płomienia Przenoszenie płomienia rurowego przerywacza płomienia, w warunkach detonacji stabilnej bez restrykcji – metoda bezpośrednia w mieszaninie gazowej PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016 Przerywacze plomienia Przenoszenie plomienia rurowego przerywacza plomienia, w warunkach detonacji stabilnej bez restrykcji – metoda bezposrednia w mieszaninie gazowej PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","categories":["other"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Flame arresters Flame transmission of an in-line flame arrester, under stable detonation conditions without restriction – direct method in a gas mixture PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","search_zh":"阻火器 PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","test_object_zh":"阻火器"},{"_id":"6a5dc9a7f1c10c8ce8259b11","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Przerywacze płomienia","test_object_en":"Flame arresters","methodology":"Przenoszenie płomienia rurowego przerywacza płomienia, w warunkach detonacji stabilnej z restrykcją – metoda bezpośrednia","methodology_en":"Flame transmission of an in-line flame arrester, under stable detonation conditions with restriction – direct method","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Przenoszenie płomienia rurowego przerywacza płomienia, w warunkach detonacji stabilnej z restrykcją – metoda bezpośrednia","reference":"PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","norm_bases":["PN-EN ISO 16852:2012","EN ISO 16852:2010","PN-EN ISO 16852:2017-02","EN ISO 16852:2016","ISO 16852:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przerywacze płomienia Przenoszenie płomienia rurowego przerywacza płomienia, w warunkach detonacji stabilnej z restrykcją – metoda bezpośrednia PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016 Przerywacze plomienia Przenoszenie plomienia rurowego przerywacza plomienia, w warunkach detonacji stabilnej z restrykcja – metoda bezposrednia PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","categories":["other"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Flame arresters Flame transmission of an in-line flame arrester, under stable detonation conditions with restriction – direct method PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","search_zh":"阻火器 PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","test_object_zh":"阻火器"},{"_id":"6a5dc9a7f1c10c8ce8259b12","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Przerywacze płomienia","test_object_en":"Flame arresters","methodology":"Przenoszenie płomienia rurowego przerywacza płomienia, w warunkach detonacji niestabilnej bez restrykcji – metoda bezpośrednia w mieszaninie gazowej","methodology_en":"Flame transmission of an in-line flame arrester, under unstable detonation conditions without restriction – direct method in a gas mixture","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Przenoszenie płomienia rurowego przerywacza płomienia, w warunkach detonacji niestabilnej bez restrykcji – metoda bezpośrednia w mieszaninie gazowej","reference":"PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","norm_bases":["PN-EN ISO 16852:2012","EN ISO 16852:2010","PN-EN ISO 16852:2017-02","EN ISO 16852:2016","ISO 16852:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przerywacze płomienia Przenoszenie płomienia rurowego przerywacza płomienia, w warunkach detonacji niestabilnej bez restrykcji – metoda bezpośrednia w mieszaninie gazowej PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016 Przerywacze plomienia Przenoszenie plomienia rurowego przerywacza plomienia, w warunkach detonacji niestabilnej bez restrykcji – metoda bezposrednia w mieszaninie gazowej PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","categories":["other"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Flame arresters Flame transmission of an in-line flame arrester, under unstable detonation conditions without restriction – direct method in a gas mixture PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","search_zh":"阻火器 PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","test_object_zh":"阻火器"},{"_id":"6a5dc9a7f1c10c8ce8259b13","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Przerywacze płomienia","test_object_en":"Flame arresters","methodology":"Przenoszenie płomienia rurowego przerywacza płomienia, w warunkach detonacji niestabilnej z restrykcją – metoda bezpośrednia w mieszaninie gazowej","methodology_en":"Flame transmission of an in-line flame arrester, under unstable detonation conditions with restriction – direct method in a gas mixture","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Przenoszenie płomienia rurowego przerywacza płomienia, w warunkach detonacji niestabilnej z restrykcją – metoda bezpośrednia w mieszaninie gazowej","reference":"PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","norm_bases":["PN-EN ISO 16852:2012","EN ISO 16852:2010","PN-EN ISO 16852:2017-02","EN ISO 16852:2016","ISO 16852:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przerywacze płomienia Przenoszenie płomienia rurowego przerywacza płomienia, w warunkach detonacji niestabilnej z restrykcją – metoda bezpośrednia w mieszaninie gazowej PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016 Przerywacze plomienia Przenoszenie plomienia rurowego przerywacza plomienia, w warunkach detonacji niestabilnej z restrykcja – metoda bezposrednia w mieszaninie gazowej PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","categories":["other"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Flame arresters Flame transmission of an in-line flame arrester, under unstable detonation conditions with restriction – direct method in a gas mixture PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","search_zh":"阻火器 PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","test_object_zh":"阻火器"},{"_id":"6a5dc9a7f1c10c8ce8259b14","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Przerywacze płomienia","test_object_en":"Flame arresters","methodology":"Spalanie krótkotrwałe – przeniesienie wybuchu; metoda bezpośrednia","methodology_en":"Short-duration combustion – explosion transmission; direct method","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Spalanie krótkotrwałe – przeniesienie wybuchu; metoda bezpośrednia","reference":"PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","norm_bases":["PN-EN ISO 16852:2012","EN ISO 16852:2010","PN-EN ISO 16852:2017-02","EN ISO 16852:2016","ISO 16852:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przerywacze płomienia Spalanie krótkotrwałe – przeniesienie wybuchu; metoda bezpośrednia PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016 Przerywacze plomienia Spalanie krotkotrwale – przeniesienie wybuchu; metoda bezposrednia PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","categories":["other"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Flame arresters Short-duration combustion – explosion transmission; direct method PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","search_zh":"阻火器 PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","test_object_zh":"阻火器"},{"_id":"6a5dc9a7f1c10c8ce8259b15","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Przerywacze płomienia","test_object_en":"Flame arresters","methodology":"Spalanie długotrwałe – przeniesienie wybuchu; metoda bezpośrednia","methodology_en":"Long-duration combustion – explosion transmission; direct method","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Spalanie długotrwałe – przeniesienie wybuchu; metoda bezpośrednia","reference":"PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","norm_bases":["PN-EN ISO 16852:2012","EN ISO 16852:2010","PN-EN ISO 16852:2017-02","EN ISO 16852:2016","ISO 16852:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Przerywacze płomienia Spalanie długotrwałe – przeniesienie wybuchu; metoda bezpośrednia PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016 Przerywacze plomienia Spalanie dlugotrwale – przeniesienie wybuchu; metoda bezposrednia PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","categories":["other"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Flame arresters Long-duration combustion – explosion transmission; direct method PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","search_zh":"阻火器 PN-EN ISO 16852:2012 | EN ISO 16852:2010 | PN-EN ISO 16852:2017-02 | EN ISO 16852:2016 | ISO 16852:2016","test_object_zh":"阻火器"},{"_id":"6a5dc9a7f1c10c8ce8259b16","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Silniki spalinowe tłokowe. Silniki grupy II przeznaczone do stosowania w atmosferze palnych gazów i par, Silniki grupy I przeznaczone do stosowania w pracach podziemnych zagrożonych występowaniem metanu i/lub palnego pyłu","test_object_en":"Reciprocating internal combustion engines. Group II engines intended for use in atmospheres containing flammable gases and vapours, Group I engines intended for use in underground work endangered by methane and/or combustible dust","methodology":"Skuteczność łapacza iskier – metoda bezpośrednia w mieszaninie gazowej","methodology_en":"Effectiveness of the spark arrester – direct method in a gas mixture","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność łapacza iskier – metoda bezpośrednia w mieszaninie gazowej","reference":"PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000","norm_bases":["PN-EN 1834-1:2002","EN 1834-1:2000","PN-EN 1834-2:2002","EN 1834-2:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Silniki spalinowe tłokowe. Silniki grupy II przeznaczone do stosowania w atmosferze palnych gazów i par, Silniki grupy I przeznaczone do stosowania w pracach podziemnych zagrożonych występowaniem metanu i/lub palnego pyłu Skuteczność łapacza iskier – metoda bezpośrednia w mieszaninie gazowej PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000 Silniki spalinowe tlokowe. Silniki grupy II przeznaczone do stosowania w atmosferze palnych gazow i par, Silniki grupy I przeznaczone do stosowania w pracach podziemnych zagrozonych wystepowaniem metanu i/lub palnego pylu Skutecznosc lapacza iskier – metoda bezposrednia w mieszaninie gazowej PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000","categories":["other"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Reciprocating internal combustion engines. Group II engines intended for use in atmospheres containing flammable gases and vapours, Group I engines intended for use in underground work endangered by methane and/or combustible dust Effectiveness of the spark arrester – direct method in a gas mixture PN-EN 1834-1:2002 | EN 1834-1:2000 | PN-EN 1834-2:2002 | EN 1834-2:2000"},{"_id":"6a5dc9a7f1c10c8ce8259b17","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Taśmy przenośnikowe","test_object_en":"Conveyor belts","methodology":"Rezystancja powierzchniowa – pomiar bezpośredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω","methodology_en":"Surface resistance – direct measurement of resistance in the range from R=500 Ω to R=1,0x1014 Ω","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja powierzchniowa – pomiar bezpośredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω","reference":"PN-EN ISO 284:2013-06 | EN ISO 284:2012 | ISO 284:2012","norm_bases":["PN-EN ISO 284:2013-06","EN ISO 284:2012","ISO 284:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Taśmy przenośnikowe Rezystancja powierzchniowa – pomiar bezpośredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω PN-EN ISO 284:2013-06 | EN ISO 284:2012 | ISO 284:2012 Tasmy przenosnikowe Rezystancja powierzchniowa – pomiar bezposredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω PN-EN ISO 284:2013-06 | EN ISO 284:2012 | ISO 284:2012","categories":["other"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Conveyor belts Surface resistance – direct measurement of resistance in the range from R=500 Ω to R=1,0x1014 Ω PN-EN ISO 284:2013-06 | EN ISO 284:2012 | ISO 284:2012","search_zh":"输送带 PN-EN ISO 284:2013-06 | EN ISO 284:2012 | ISO 284:2012","test_object_zh":"输送带"},{"_id":"6a5dc9a7f1c10c8ce8259b18","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Guma przewodząca i rozpraszająca","test_object_en":"Conductive and dissipative rubber","methodology":"Rezystancja powierzchniowa – pomiar bezpośredni rezystancji w zakresie od, R=500 Ω do R=1,0x1014 Ω","methodology_en":"Surface resistance – direct measurement of resistance in the range from R=500 Ω to R=1,0x1014 Ω","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja powierzchniowa – pomiar bezpośredni rezystancji w zakresie od, R=500 Ω do R=1,0x1014 Ω","reference":"ISO 1853:2011-06","norm_bases":["ISO 1853:2011-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Guma przewodząca i rozpraszająca Rezystancja powierzchniowa – pomiar bezpośredni rezystancji w zakresie od, R=500 Ω do R=1,0x1014 Ω ISO 1853:2011-06 Guma przewodzaca i rozpraszajaca Rezystancja powierzchniowa – pomiar bezposredni rezystancji w zakresie od, R=500 Ω do R=1,0x1014 Ω ISO 1853:2011-06","categories":["materials"],"row_index":72,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Conductive and dissipative rubber Surface resistance – direct measurement of resistance in the range from R=500 Ω to R=1,0x1014 Ω ISO 1853:2011-06","methodology_zh":"表面电阻 － 电阻直接测量，范围自 R=500 Ω 至 R=1,0x1014 Ω","search_zh":"表面电阻 － 电阻直接测量，范围自 R=500 Ω 至 R=1,0x1014 Ω ISO 1853:2011-06"},{"_id":"6a5dc9a7f1c10c8ce8259b19","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Tworzywa sztuczne, Obudowy i elementy obudów urządzeń wykonane z tworzyw sztucznych","test_object_en":"Plastics, Enclosures and enclosure parts of equipment made of plastics","methodology":"Rezystancja powierzchniowa – pomiar bezpośredni rezystancji w zakresie od, R=500 Ω do R=1,0x1014 Ω","methodology_en":"Surface resistance – direct measurement of resistance in the range from R=500 Ω to R=1,0x1014 Ω","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja powierzchniowa – pomiar bezpośredni rezystancji w zakresie od, R=500 Ω do R=1,0x1014 Ω","reference":"PN-EN ISO 3915:2002 | EN ISO 3915:1999 | ISO 3915:1981 | PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011-06 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","norm_bases":["PN-EN ISO 3915:2002","EN ISO 3915:1999","ISO 3915:1981","PN-EN 60079-0:2013-03","EN 60079-0:2012","IEC 60079-0:2011-06 ed.6.0","PN-EN 60079-0:2013-03/A11:2014-03","EN 60079-0:2012/A11:2013","IEC 60079-0:2017 ed.7.0","PN-EN IEC 60079-0:2018-09","EN IEC 60079-0:2018","IEC 60079-0:2017","PN-EN ISO 80079-36:2016-07","EN ISO 80079-36:2016","ISO 80079-36:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Tworzywa sztuczne, Obudowy i elementy obudów urządzeń wykonane z tworzyw sztucznych Rezystancja powierzchniowa – pomiar bezpośredni rezystancji w zakresie od, R=500 Ω do R=1,0x1014 Ω PN-EN ISO 3915:2002 | EN ISO 3915:1999 | ISO 3915:1981 | PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011-06 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016 Tworzywa sztuczne, Obudowy i elementy obudow urzadzen wykonane z tworzyw sztucznych Rezystancja powierzchniowa – pomiar bezposredni rezystancji w zakresie od, R=500 Ω do R=1,0x1014 Ω PN-EN ISO 3915:2002 | EN ISO 3915:1999 | ISO 3915:1981 | PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011-06 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","categories":["materials"],"row_index":73,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Plastics, Enclosures and enclosure parts of equipment made of plastics Surface resistance – direct measurement of resistance in the range from R=500 Ω to R=1,0x1014 Ω PN-EN ISO 3915:2002 | EN ISO 3915:1999 | ISO 3915:1981 | PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011-06 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016","methodology_zh":"表面电阻 － 电阻直接测量，范围自 R=500 Ω 至 R=1,0x1014 Ω","search_zh":"表面电阻 － 电阻直接测量，范围自 R=500 Ω 至 R=1,0x1014 Ω PN-EN ISO 3915:2002 | EN ISO 3915:1999 | ISO 3915:1981 | PN-EN 60079-0:2013-03 | EN 60079-0:2012 | IEC 60079-0:2011-06 ed.6.0 | PN-EN 60079-0:2013-03/A11:2014-03 | EN 60079-0:2012/A11:2013 | IEC 60079-0:2017 ed.7.0 | PN-EN IEC 60079-0:2018-09 | EN IEC 60079-0:2018 | IEC 60079-0:2017 | PN-EN ISO 80079-36:2016-07 | EN ISO 80079-36:2016 | ISO 80079-36:2016"},{"_id":"6a5dc9a7f1c10c8ce8259b1a","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Materiały niemetalowe stałe","test_object_en":"Solid non-metallic materials","methodology":"Rezystancja skrośna – pomiar bezpośredni rezystancji w zakresie od, R=500 Ω do R=1,0x1014 Ω","methodology_en":"Volume resistance – direct measurement of resistance in the range from, R=500 Ω to R=1,0x1014 Ω","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja skrośna – pomiar bezpośredni rezystancji w zakresie od, R=500 Ω do R=1,0x1014 Ω","reference":"PN-EN 61340-2-3:2002 | EN 61340-2-3:2000 | IEC 61340-2-3:2000 ed 1.0 | PN-EN 61340-2-3:2016-11 | EN 61340-2-3:2016 | IEC 61340-2-3:2016 ed. 2.0","norm_bases":["PN-EN 61340-2-3:2002","EN 61340-2-3:2000","IEC 61340-2-3:2000 ed 1.0","PN-EN 61340-2-3:2016-11","EN 61340-2-3:2016","IEC 61340-2-3:2016 ed. 2.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały niemetalowe stałe Rezystancja skrośna – pomiar bezpośredni rezystancji w zakresie od, R=500 Ω do R=1,0x1014 Ω PN-EN 61340-2-3:2002 | EN 61340-2-3:2000 | IEC 61340-2-3:2000 ed 1.0 | PN-EN 61340-2-3:2016-11 | EN 61340-2-3:2016 | IEC 61340-2-3:2016 ed. 2.0 Materialy niemetalowe stale Rezystancja skrosna – pomiar bezposredni rezystancji w zakresie od, R=500 Ω do R=1,0x1014 Ω PN-EN 61340-2-3:2002 | EN 61340-2-3:2000 | IEC 61340-2-3:2000 ed 1.0 | PN-EN 61340-2-3:2016-11 | EN 61340-2-3:2016 | IEC 61340-2-3:2016 ed. 2.0","categories":["materials"],"row_index":74,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid non-metallic materials Volume resistance – direct measurement of resistance in the range from, R=500 Ω to R=1,0x1014 Ω PN-EN 61340-2-3:2002 | EN 61340-2-3:2000 | IEC 61340-2-3:2000 ed 1.0 | PN-EN 61340-2-3:2016-11 | EN 61340-2-3:2016 | IEC 61340-2-3:2016 ed. 2.0","search_zh":"固体非金属材料 PN-EN 61340-2-3:2002 | EN 61340-2-3:2000 | IEC 61340-2-3:2000 ed 1.0 | PN-EN 61340-2-3:2016-11 | EN 61340-2-3:2016 | IEC 61340-2-3:2016 ed. 2.0","test_object_zh":"固体非金属材料"},{"_id":"6a5dc9a7f1c10c8ce8259b1b","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Materiały niemetalowe stałe","test_object_en":"Solid non-metallic materials","methodology":"Rezystancja powierzchniowa – pomiar bezpośredni rezystancji w zakresie od, R=500 Ω do R=1,0x1014 Ω","methodology_en":"Surface resistance – direct measurement of resistance in the range from R=500 Ω to R=1,0x1014 Ω","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja powierzchniowa – pomiar bezpośredni rezystancji w zakresie od, R=500 Ω do R=1,0x1014 Ω","reference":"PN-EN 61340-2-3:2002 | EN 61340-2-3:2000 | IEC 61340-2-3:2000 ed 1.0 | PN-EN 61340-2-3:2016-11 | EN 61340-2-3:2016 | IEC 61340-2-3:2016 ed. 2.0","norm_bases":["PN-EN 61340-2-3:2002","EN 61340-2-3:2000","IEC 61340-2-3:2000 ed 1.0","PN-EN 61340-2-3:2016-11","EN 61340-2-3:2016","IEC 61340-2-3:2016 ed. 2.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały niemetalowe stałe Rezystancja powierzchniowa – pomiar bezpośredni rezystancji w zakresie od, R=500 Ω do R=1,0x1014 Ω PN-EN 61340-2-3:2002 | EN 61340-2-3:2000 | IEC 61340-2-3:2000 ed 1.0 | PN-EN 61340-2-3:2016-11 | EN 61340-2-3:2016 | IEC 61340-2-3:2016 ed. 2.0 Materialy niemetalowe stale Rezystancja powierzchniowa – pomiar bezposredni rezystancji w zakresie od, R=500 Ω do R=1,0x1014 Ω PN-EN 61340-2-3:2002 | EN 61340-2-3:2000 | IEC 61340-2-3:2000 ed 1.0 | PN-EN 61340-2-3:2016-11 | EN 61340-2-3:2016 | IEC 61340-2-3:2016 ed. 2.0","categories":["materials"],"row_index":75,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid non-metallic materials Surface resistance – direct measurement of resistance in the range from R=500 Ω to R=1,0x1014 Ω PN-EN 61340-2-3:2002 | EN 61340-2-3:2000 | IEC 61340-2-3:2000 ed 1.0 | PN-EN 61340-2-3:2016-11 | EN 61340-2-3:2016 | IEC 61340-2-3:2016 ed. 2.0","methodology_zh":"表面电阻 － 电阻直接测量，范围自 R=500 Ω 至 R=1,0x1014 Ω","search_zh":"固体非金属材料 表面电阻 － 电阻直接测量，范围自 R=500 Ω 至 R=1,0x1014 Ω PN-EN 61340-2-3:2002 | EN 61340-2-3:2000 | IEC 61340-2-3:2000 ed 1.0 | PN-EN 61340-2-3:2016-11 | EN 61340-2-3:2016 | IEC 61340-2-3:2016 ed. 2.0","test_object_zh":"固体非金属材料"},{"_id":"6a5dc9a7f1c10c8ce8259b1c","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Materiały niemetalowe stałe","test_object_en":"Solid non-metallic materials","methodology":"Rezystancja względem elementu uziemiającego – pomiar bezpośredni rezystancji w zakresie od R=500 Ω do, R=1,0x1014 Ω","methodology_en":"Resistance to the earthing element – direct measurement of resistance in the range from, R=500 Ω to R=1,0x1014 Ω","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja względem elementu uziemiającego – pomiar bezpośredni rezystancji w zakresie od R=500 Ω do, R=1,0x1014 Ω","reference":"PN-EN 61340-2-3:2002 | EN 61340-2-3:2000 | IEC 61340-2-3:2000 ed 1.0 | PN-EN 61340-2-3:2016-11 | EN 61340-2-3:2016 | IEC 61340-2-3:2016 ed. 2.0","norm_bases":["PN-EN 61340-2-3:2002","EN 61340-2-3:2000","IEC 61340-2-3:2000 ed 1.0","PN-EN 61340-2-3:2016-11","EN 61340-2-3:2016","IEC 61340-2-3:2016 ed. 2.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały niemetalowe stałe Rezystancja względem elementu uziemiającego – pomiar bezpośredni rezystancji w zakresie od R=500 Ω do, R=1,0x1014 Ω PN-EN 61340-2-3:2002 | EN 61340-2-3:2000 | IEC 61340-2-3:2000 ed 1.0 | PN-EN 61340-2-3:2016-11 | EN 61340-2-3:2016 | IEC 61340-2-3:2016 ed. 2.0 Materialy niemetalowe stale Rezystancja wzgledem elementu uziemiajacego – pomiar bezposredni rezystancji w zakresie od R=500 Ω do, R=1,0x1014 Ω PN-EN 61340-2-3:2002 | EN 61340-2-3:2000 | IEC 61340-2-3:2000 ed 1.0 | PN-EN 61340-2-3:2016-11 | EN 61340-2-3:2016 | IEC 61340-2-3:2016 ed. 2.0","categories":["materials"],"row_index":76,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid non-metallic materials Resistance to the earthing element – direct measurement of resistance in the range from, R=500 Ω to R=1,0x1014 Ω PN-EN 61340-2-3:2002 | EN 61340-2-3:2000 | IEC 61340-2-3:2000 ed 1.0 | PN-EN 61340-2-3:2016-11 | EN 61340-2-3:2016 | IEC 61340-2-3:2016 ed. 2.0","search_zh":"固体非金属材料 PN-EN 61340-2-3:2002 | EN 61340-2-3:2000 | IEC 61340-2-3:2000 ed 1.0 | PN-EN 61340-2-3:2016-11 | EN 61340-2-3:2016 | IEC 61340-2-3:2016 ed. 2.0","test_object_zh":"固体非金属材料"},{"_id":"6a5dc9a7f1c10c8ce8259b1d","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Materiały niemetalowe stałe","test_object_en":"Solid non-metallic materials","methodology":"Rezystancja między punktami – pomiar bezpośredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω","methodology_en":"Point-to-point resistance – direct measurement of resistance in the range from R=500 Ω to R=1,0x1014 Ω","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja między punktami – pomiar bezpośredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω","reference":"PN-EN 61340-2-3:2002 | EN 61340-2-3:2000 | IEC 61340-2-3:2000 ed 1.0 | PN-EN 61340-2-3:2016-11 | EN 61340-2-3:2016 | IEC 61340-2-3:2016 ed. 2.0","norm_bases":["PN-EN 61340-2-3:2002","EN 61340-2-3:2000","IEC 61340-2-3:2000 ed 1.0","PN-EN 61340-2-3:2016-11","EN 61340-2-3:2016","IEC 61340-2-3:2016 ed. 2.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały niemetalowe stałe Rezystancja między punktami – pomiar bezpośredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω PN-EN 61340-2-3:2002 | EN 61340-2-3:2000 | IEC 61340-2-3:2000 ed 1.0 | PN-EN 61340-2-3:2016-11 | EN 61340-2-3:2016 | IEC 61340-2-3:2016 ed. 2.0 Materialy niemetalowe stale Rezystancja miedzy punktami – pomiar bezposredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω PN-EN 61340-2-3:2002 | EN 61340-2-3:2000 | IEC 61340-2-3:2000 ed 1.0 | PN-EN 61340-2-3:2016-11 | EN 61340-2-3:2016 | IEC 61340-2-3:2016 ed. 2.0","categories":["materials"],"row_index":77,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid non-metallic materials Point-to-point resistance – direct measurement of resistance in the range from R=500 Ω to R=1,0x1014 Ω PN-EN 61340-2-3:2002 | EN 61340-2-3:2000 | IEC 61340-2-3:2000 ed 1.0 | PN-EN 61340-2-3:2016-11 | EN 61340-2-3:2016 | IEC 61340-2-3:2016 ed. 2.0","search_zh":"固体非金属材料 PN-EN 61340-2-3:2002 | EN 61340-2-3:2000 | IEC 61340-2-3:2000 ed 1.0 | PN-EN 61340-2-3:2016-11 | EN 61340-2-3:2016 | IEC 61340-2-3:2016 ed. 2.0","test_object_zh":"固体非金属材料"},{"_id":"6a5dc9a7f1c10c8ce8259b1e","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Węże i przewody gumowe i z tworzyw sztucznych.","test_object_en":"Rubber and plastics hoses and tubing.","methodology":"Rezystancja – pomiar bezpośredni rezystancji w zakresie od R=500 Ω do, R=1,0x1014 Ω","methodology_en":"Resistance – direct measurement of resistance in the range from R=500 Ω to, R=1,0x1014 Ω","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja – pomiar bezpośredni rezystancji w zakresie od R=500 Ω do, R=1,0x1014 Ω","reference":"PN-EN ISO 8031:2010 | EN ISO 8031:2009","norm_bases":["PN-EN ISO 8031:2010","EN ISO 8031:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Węże i przewody gumowe i z tworzyw sztucznych. Rezystancja – pomiar bezpośredni rezystancji w zakresie od R=500 Ω do, R=1,0x1014 Ω PN-EN ISO 8031:2010 | EN ISO 8031:2009 Weze i przewody gumowe i z tworzyw sztucznych. Rezystancja – pomiar bezposredni rezystancji w zakresie od R=500 Ω do, R=1,0x1014 Ω PN-EN ISO 8031:2010 | EN ISO 8031:2009","categories":["other"],"row_index":78,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rubber and plastics hoses and tubing. Resistance – direct measurement of resistance in the range from R=500 Ω to, R=1,0x1014 Ω PN-EN ISO 8031:2010 | EN ISO 8031:2009"},{"_id":"6a5dc9a7f1c10c8ce8259b1f","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Odzież ochronna","test_object_en":"Protective clothing","methodology":"Rezystancja powierzchniowa – pomiar bezpośredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω","methodology_en":"Surface resistance – direct measurement of resistance in the range from R=500 Ω to R=1,0x1014 Ω","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja powierzchniowa – pomiar bezpośredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω","reference":"PN-EN 1149-1:2008 | EN 1149-1:2006","norm_bases":["PN-EN 1149-1:2008","EN 1149-1:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odzież ochronna Rezystancja powierzchniowa – pomiar bezpośredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω PN-EN 1149-1:2008 | EN 1149-1:2006 Odziez ochronna Rezystancja powierzchniowa – pomiar bezposredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω PN-EN 1149-1:2008 | EN 1149-1:2006","categories":["other"],"row_index":79,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Protective clothing Surface resistance – direct measurement of resistance in the range from R=500 Ω to R=1,0x1014 Ω PN-EN 1149-1:2008 | EN 1149-1:2006"},{"_id":"6a5dc9a7f1c10c8ce8259b20","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Odzież ochronna","test_object_en":"Protective clothing","methodology":"Rezystancja skrośna – pomiar bezpośredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω","methodology_en":"Volume resistance – direct measurement of resistance in the range from R=500 Ω to R=1,0x1014 Ω","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja skrośna – pomiar bezpośredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω","reference":"PN-EN 1149-2:1999 | EN 1149-2:1997","norm_bases":["PN-EN 1149-2:1999","EN 1149-2:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odzież ochronna Rezystancja skrośna – pomiar bezpośredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω PN-EN 1149-2:1999 | EN 1149-2:1997 Odziez ochronna Rezystancja skrosna – pomiar bezposredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω PN-EN 1149-2:1999 | EN 1149-2:1997","categories":["other"],"row_index":80,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Protective clothing Volume resistance – direct measurement of resistance in the range from R=500 Ω to R=1,0x1014 Ω PN-EN 1149-2:1999 | EN 1149-2:1997"},{"_id":"6a5dc9a7f1c10c8ce8259b21","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Środki ochrony indywidualnej - obuwie","test_object_en":"Personal protective equipment - footwear","methodology":"Rezystancja skrośna podeszwy – pomiar bezpośredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω","methodology_en":"Volume resistance of the sole – direct measurement of resistance in the range from R=500 Ω to R=1,0x1014 Ω","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja skrośna podeszwy – pomiar bezpośredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω","reference":"PN-EN ISO 20344:2022-04E | EN ISO 20344:2021 | ISO 20344:2021","norm_bases":["PN-EN ISO 20344:2022-04E","EN ISO 20344:2021","ISO 20344:2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środki ochrony indywidualnej - obuwie Rezystancja skrośna podeszwy – pomiar bezpośredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω PN-EN ISO 20344:2022-04E | EN ISO 20344:2021 | ISO 20344:2021 Srodki ochrony indywidualnej - obuwie Rezystancja skrosna podeszwy – pomiar bezposredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω PN-EN ISO 20344:2022-04E | EN ISO 20344:2021 | ISO 20344:2021","categories":["other"],"row_index":81,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Personal protective equipment - footwear Volume resistance of the sole – direct measurement of resistance in the range from R=500 Ω to R=1,0x1014 Ω PN-EN ISO 20344:2022-04E | EN ISO 20344:2021 | ISO 20344:2021"},{"_id":"6a5dc9a7f1c10c8ce8259b22","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Wykładziny podłogowe i gotowe podłogi","test_object_en":"Floor coverings and ready-made floors","methodology":"Rezystancja – badania laboratoryjne:","methodology_en":"Resistance – laboratory tests:","parameters":[{"name":"R, Rv, Ru"},{"name":"Rezystancja – badania odbiorcze: R, Ru pomiar bezpośredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω"}],"parameters_en":[{"name":"R, Rv, Ru"},{"name":"Resistance – acceptance tests: R, Ru direct measurement of resistance in the range from R=500 Ω to R=1,0x1014 Ω"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja – badania laboratoryjne:\nZakres:\nR, Rv, Ru\nRezystancja – badania odbiorcze: R, Ru pomiar bezpośredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω","reference":"PN-EN 61340-4-1:2006 /A1:2015-07 | EN 61340-4-1:2004/A1:2015 | IEC 61340-4-1:2003+AMD12015 CSV ed. 2.1","norm_bases":["PN-EN 61340-4-1:2006 /A1:2015-07","EN 61340-4-1:2004/A1:2015","IEC 61340-4-1:2003+AMD12015 CSV ed. 2.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wykładziny podłogowe i gotowe podłogi Rezystancja – badania laboratoryjne:\nZakres:\nR, Rv, Ru\nRezystancja – badania odbiorcze: R, Ru pomiar bezpośredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω PN-EN 61340-4-1:2006 /A1:2015-07 | EN 61340-4-1:2004/A1:2015 | IEC 61340-4-1:2003+AMD12015 CSV ed. 2.1 Wykladziny podlogowe i gotowe podlogi Rezystancja – badania laboratoryjne:\nZakres:\nR, Rv, Ru\nRezystancja – badania odbiorcze: R, Ru pomiar bezposredni rezystancji w zakresie od R=500 Ω do R=1,0x1014 Ω PN-EN 61340-4-1:2006 /A1:2015-07 | EN 61340-4-1:2004/A1:2015 | IEC 61340-4-1:2003+AMD12015 CSV ed. 2.1","categories":["other"],"row_index":82,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Floor coverings and ready-made floors Resistance – laboratory tests: R, Rv, Ru Resistance – acceptance tests: R, Ru direct measurement of resistance in the range from R=500 Ω to R=1,0x1014 Ω PN-EN 61340-4-1:2006 /A1:2015-07 | EN 61340-4-1:2004/A1:2015 | IEC 61340-4-1:2003+AMD12015 CSV ed. 2.1"},{"_id":"6a5dc9a7f1c10c8ce8259b23","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Osłony gazowe z nadciśnieniem „p”","test_object_en":"Pressurized enclosures „p”","methodology":"Skuteczność przewietrzania – badanie bezpośrednie poprzez pomiary stężeń","methodology_en":"Ventilation effectiveness – direct testing by concentration measurements","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność przewietrzania – badanie bezpośrednie poprzez pomiary stężeń","reference":"PN-EN 60079-2:2010 | EN 60079-2:2007 | IEC 60079-2:2007 ed.5.0 | PN-EN 60079-2:2015-02 | EN 60079-2:2014 | IEC 60079-2:2014 ed.6.0","norm_bases":["PN-EN 60079-2:2010","EN 60079-2:2007","IEC 60079-2:2007 ed.5.0","PN-EN 60079-2:2015-02","EN 60079-2:2014","IEC 60079-2:2014 ed.6.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osłony gazowe z nadciśnieniem „p” Skuteczność przewietrzania – badanie bezpośrednie poprzez pomiary stężeń PN-EN 60079-2:2010 | EN 60079-2:2007 | IEC 60079-2:2007 ed.5.0 | PN-EN 60079-2:2015-02 | EN 60079-2:2014 | IEC 60079-2:2014 ed.6.0 Oslony gazowe z nadcisnieniem „p” Skutecznosc przewietrzania – badanie bezposrednie poprzez pomiary stezen PN-EN 60079-2:2010 | EN 60079-2:2007 | IEC 60079-2:2007 ed.5.0 | PN-EN 60079-2:2015-02 | EN 60079-2:2014 | IEC 60079-2:2014 ed.6.0","categories":["other"],"row_index":83,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pressurized enclosures „p” Ventilation effectiveness – direct testing by concentration measurements PN-EN 60079-2:2010 | EN 60079-2:2007 | IEC 60079-2:2007 ed.5.0 | PN-EN 60079-2:2015-02 | EN 60079-2:2014 | IEC 60079-2:2014 ed.6.0"},{"_id":"6a5dc9a7f1c10c8ce8259b24","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia przeciwwybuchowe w osłonie piaskowej „q”","test_object_en":"Explosion-proof equipment with powder filling “q”","methodology":"Wytrzymałościć dielektryczna wypełniacza – badanie bezpośrednie napięciem o wartości od 500 V do 30 kV","methodology_en":"Dielectric strength of the filler – direct test with voltage from 500 V to 30 kV","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałościć dielektryczna wypełniacza – badanie bezpośrednie napięciem o wartości od 500 V do 30 kV","reference":"PN-EN 60079-5:2010 | EN 60079-5:2007 | IEC 60079-5:2007ed.3.0 | PN-EN 60079-5:2015-08 | EN 60079-5:2015 | IEC 60079-5:2015 ed.4.0","norm_bases":["PN-EN 60079-5:2010","EN 60079-5:2007","IEC 60079-5:2007ed.3.0","PN-EN 60079-5:2015-08","EN 60079-5:2015","IEC 60079-5:2015 ed.4.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia przeciwwybuchowe w osłonie piaskowej „q” Wytrzymałościć dielektryczna wypełniacza – badanie bezpośrednie napięciem o wartości od 500 V do 30 kV PN-EN 60079-5:2010 | EN 60079-5:2007 | IEC 60079-5:2007ed.3.0 | PN-EN 60079-5:2015-08 | EN 60079-5:2015 | IEC 60079-5:2015 ed.4.0 Urzadzenia przeciwwybuchowe w oslonie piaskowej „q” Wytrzymaloscic dielektryczna wypelniacza – badanie bezposrednie napieciem o wartosci od 500 V do 30 kV PN-EN 60079-5:2010 | EN 60079-5:2007 | IEC 60079-5:2007ed.3.0 | PN-EN 60079-5:2015-08 | EN 60079-5:2015 | IEC 60079-5:2015 ed.4.0","categories":["other"],"row_index":84,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-proof equipment with powder filling “q” Dielectric strength of the filler – direct test with voltage from 500 V to 30 kV PN-EN 60079-5:2010 | EN 60079-5:2007 | IEC 60079-5:2007ed.3.0 | PN-EN 60079-5:2015-08 | EN 60079-5:2015 | IEC 60079-5:2015 ed.4.0"},{"_id":"6a5dc9a7f1c10c8ce8259b25","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia przeciwwybuchowe w osłonie olejowej „o”","test_object_en":"Explosion-proof equipment with liquid immersion “o”","methodology":"Wytrzymałość obudowy – badania bezpośrednie poprzez wytworzenie podciśnienia o wartości do 30 kPa","methodology_en":"Strength of the enclosure – direct tests by generating a vacuum of up to 30 kPa","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość obudowy – badania bezpośrednie poprzez wytworzenie podciśnienia o wartości do 30 kPa","reference":"PN-EN 60079-6:2010 | EN 60079-6:2007 | IEC 60079-6:2007 ed.3.0 | PN-EN 60079-6:2016-02 | EN 60079-6:2015 | IEC 60079-6:2015 ed. 4.0","norm_bases":["PN-EN 60079-6:2010","EN 60079-6:2007","IEC 60079-6:2007 ed.3.0","PN-EN 60079-6:2016-02","EN 60079-6:2015","IEC 60079-6:2015 ed. 4.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia przeciwwybuchowe w osłonie olejowej „o” Wytrzymałość obudowy – badania bezpośrednie poprzez wytworzenie podciśnienia o wartości do 30 kPa PN-EN 60079-6:2010 | EN 60079-6:2007 | IEC 60079-6:2007 ed.3.0 | PN-EN 60079-6:2016-02 | EN 60079-6:2015 | IEC 60079-6:2015 ed. 4.0 Urzadzenia przeciwwybuchowe w oslonie olejowej „o” Wytrzymalosc obudowy – badania bezposrednie poprzez wytworzenie podcisnienia o wartosci do 30 kPa PN-EN 60079-6:2010 | EN 60079-6:2007 | IEC 60079-6:2007 ed.3.0 | PN-EN 60079-6:2016-02 | EN 60079-6:2015 | IEC 60079-6:2015 ed. 4.0","categories":["petro"],"row_index":85,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-proof equipment with liquid immersion “o” Strength of the enclosure – direct tests by generating a vacuum of up to 30 kPa PN-EN 60079-6:2010 | EN 60079-6:2007 | IEC 60079-6:2007 ed.3.0 | PN-EN 60079-6:2016-02 | EN 60079-6:2015 | IEC 60079-6:2015 ed. 4.0"},{"_id":"6a5dc9a7f1c10c8ce8259b26","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia przeciwwybuchowe iskrobezpieczne „i”","test_object_en":"Explosion-protected intrinsically safe equipment „i”","methodology":"Iskrobezpieczeństwo obwodów – badanie za pomocą iskiernika","methodology_en":"Intrinsic safety of circuits – testing with a spark test apparatus","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Iskrobezpieczeństwo obwodów – badanie za pomocą iskiernika","reference":"PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0","norm_bases":["PN-EN 60079-11:2012","EN 60079-11:2012","IEC 60079-11:2011 ed.6.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia przeciwwybuchowe iskrobezpieczne „i” Iskrobezpieczeństwo obwodów – badanie za pomocą iskiernika PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0 Urzadzenia przeciwwybuchowe iskrobezpieczne „i” Iskrobezpieczenstwo obwodow – badanie za pomoca iskiernika PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0","categories":["other"],"row_index":86,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected intrinsically safe equipment „i” Intrinsic safety of circuits – testing with a spark test apparatus PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0","search_zh":"本质安全型「i」防爆设备 PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0","test_object_zh":"本质安全型「i」防爆设备"},{"_id":"6a5dc9a7f1c10c8ce8259b27","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia przeciwwybuchowe iskrobezpieczne „i”","test_object_en":"Explosion-protected intrinsically safe equipment „i”","methodology":"Energia obwodów w stanach przejściowych – pomiar bezpośredni","methodology_en":"Circuit energy under transient conditions – direct measurement","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Energia obwodów w stanach przejściowych – pomiar bezpośredni","reference":"PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0","norm_bases":["PN-EN 60079-11:2012","EN 60079-11:2012","IEC 60079-11:2011 ed.6.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia przeciwwybuchowe iskrobezpieczne „i” Energia obwodów w stanach przejściowych – pomiar bezpośredni PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0 Urzadzenia przeciwwybuchowe iskrobezpieczne „i” Energia obwodow w stanach przejsciowych – pomiar bezposredni PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0","categories":["other"],"row_index":87,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected intrinsically safe equipment „i” Circuit energy under transient conditions – direct measurement PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0","search_zh":"本质安全型「i」防爆设备 PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0","test_object_zh":"本质安全型「i」防爆设备"},{"_id":"6a5dc9a7f1c10c8ce8259b28","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia przeciwwybuchowe iskrobezpieczne „i”","test_object_en":"Explosion-protected intrinsically safe equipment „i”","methodology":"Wyciek elektrolitu – badanie bezpośrednie","methodology_en":"Electrolyte leakage – direct testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wyciek elektrolitu – badanie bezpośrednie","reference":"PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0","norm_bases":["PN-EN 60079-11:2012","EN 60079-11:2012","IEC 60079-11:2011 ed.6.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia przeciwwybuchowe iskrobezpieczne „i” Wyciek elektrolitu – badanie bezpośrednie PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0 Urzadzenia przeciwwybuchowe iskrobezpieczne „i” Wyciek elektrolitu – badanie bezposrednie PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0","categories":["other"],"row_index":88,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected intrinsically safe equipment „i” Electrolyte leakage – direct testing PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0","search_zh":"本质安全型「i」防爆设备 PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0","test_object_zh":"本质安全型「i」防爆设备"},{"_id":"6a5dc9a7f1c10c8ce8259b29","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia przeciwwybuchowe iskrobezpieczne „i”","test_object_en":"Explosion-protected intrinsically safe equipment „i”","methodology":"Wytrzymałość zalew i przegród – badania bezpośrednie poprzez oddziaływanie siłą w zakresie od 1 N do 5000 N","methodology_en":"Strength of sealing compounds and partitions – direct tests by applying a force in the range from 1 N to 5000 N","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość zalew i przegród – badania bezpośrednie poprzez oddziaływanie siłą w zakresie od 1 N do 5000 N","reference":"PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0","norm_bases":["PN-EN 60079-11:2012","EN 60079-11:2012","IEC 60079-11:2011 ed.6.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia przeciwwybuchowe iskrobezpieczne „i” Wytrzymałość zalew i przegród – badania bezpośrednie poprzez oddziaływanie siłą w zakresie od 1 N do 5000 N PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0 Urzadzenia przeciwwybuchowe iskrobezpieczne „i” Wytrzymalosc zalew i przegrod – badania bezposrednie poprzez oddzialywanie sila w zakresie od 1 N do 5000 N PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0","categories":["other"],"row_index":89,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected intrinsically safe equipment „i” Strength of sealing compounds and partitions – direct tests by applying a force in the range from 1 N to 5000 N PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0","search_zh":"本质安全型「i」防爆设备 PN-EN 60079-11:2012 | EN 60079-11:2012 | IEC 60079-11:2011 ed.6.0","test_object_zh":"本质安全型「i」防爆设备"},{"_id":"6a5dc9a7f1c10c8ce8259b2a","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia budowy przeciwwybuchowej \"n\"","test_object_en":"Explosion-protected equipment of type of protection \"n\"","methodology":"Zapłon wywołany osłoniętymi stykami – badanie bezpośrednie w mieszaninie gazowej","methodology_en":"Ignition caused by enclosed contacts – direct test in a gas mixture","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zapłon wywołany osłoniętymi stykami – badanie bezpośrednie w mieszaninie gazowej","reference":"PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","norm_bases":["PN-EN 60079-15:2010","EN 60079-15:2010","IEC 60079-15:2010 ed.4.0","IEC 60079-15:2017 ed. 5.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia budowy przeciwwybuchowej \"n\" Zapłon wywołany osłoniętymi stykami – badanie bezpośrednie w mieszaninie gazowej PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0 Urzadzenia budowy przeciwwybuchowej \"n\" Zaplon wywolany oslonietymi stykami – badanie bezposrednie w mieszaninie gazowej PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","categories":["other"],"row_index":90,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected equipment of type of protection \"n\" Ignition caused by enclosed contacts – direct test in a gas mixture PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","search_zh":"「n」型防爆结构设备 PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","test_object_zh":"「n」型防爆结构设备"},{"_id":"6a5dc9a7f1c10c8ce8259b2b","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia budowy przeciwwybuchowej \"n\"","test_object_en":"Explosion-protected equipment of type of protection \"n\"","methodology":"Iskrobezpieczeństwo obwodów – badanie za pomocą iskiernika","methodology_en":"Intrinsic safety of circuits – testing with a spark test apparatus","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Iskrobezpieczeństwo obwodów – badanie za pomocą iskiernika","reference":"PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","norm_bases":["PN-EN 60079-15:2010","EN 60079-15:2010","IEC 60079-15:2010 ed.4.0","IEC 60079-15:2017 ed. 5.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia budowy przeciwwybuchowej \"n\" Iskrobezpieczeństwo obwodów – badanie za pomocą iskiernika PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0 Urzadzenia budowy przeciwwybuchowej \"n\" Iskrobezpieczenstwo obwodow – badanie za pomoca iskiernika PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","categories":["other"],"row_index":91,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected equipment of type of protection \"n\" Intrinsic safety of circuits – testing with a spark test apparatus PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","search_zh":"「n」型防爆结构设备 PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","test_object_zh":"「n」型防爆结构设备"},{"_id":"6a5dc9a7f1c10c8ce8259b2c","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia budowy przeciwwybuchowej \"n\"","test_object_en":"Explosion-protected equipment of type of protection \"n\"","methodology":"Szczelność urządzeń – badanie bezpośrednie poprzez wytworzenie podciśnienia: Wartość podciśnienia do 30 Pa","methodology_en":"Tightness of equipment – direct testing by generating negative pressure: Negative pressure value up to 30 Pa","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Szczelność urządzeń – badanie bezpośrednie poprzez wytworzenie podciśnienia: Wartość podciśnienia do 30 Pa","reference":"PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","norm_bases":["PN-EN 60079-15:2010","EN 60079-15:2010","IEC 60079-15:2010 ed.4.0","IEC 60079-15:2017 ed. 5.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia budowy przeciwwybuchowej \"n\" Szczelność urządzeń – badanie bezpośrednie poprzez wytworzenie podciśnienia: Wartość podciśnienia do 30 Pa PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0 Urzadzenia budowy przeciwwybuchowej \"n\" Szczelnosc urzadzen – badanie bezposrednie poprzez wytworzenie podcisnienia: Wartosc podcisnienia do 30 Pa PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","categories":["other"],"row_index":92,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected equipment of type of protection \"n\" Tightness of equipment – direct testing by generating negative pressure: Negative pressure value up to 30 Pa PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","search_zh":"「n」型防爆结构设备 PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","test_object_zh":"「n」型防爆结构设备"},{"_id":"6a5dc9a7f1c10c8ce8259b2d","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia budowy przeciwwybuchowej \"n\"","test_object_en":"Explosion-protected equipment of type of protection \"n\"","methodology":"Zapłon przez maszyny na wysokie napięcie – badanie bezpośrednie w mieszaninie gazowej","methodology_en":"Ignition by high-voltage machines – direct test in a gas mixture","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zapłon przez maszyny na wysokie napięcie – badanie bezpośrednie w mieszaninie gazowej","reference":"PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","norm_bases":["PN-EN 60079-15:2010","EN 60079-15:2010","IEC 60079-15:2010 ed.4.0","IEC 60079-15:2017 ed. 5.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia budowy przeciwwybuchowej \"n\" Zapłon przez maszyny na wysokie napięcie – badanie bezpośrednie w mieszaninie gazowej PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0 Urzadzenia budowy przeciwwybuchowej \"n\" Zaplon przez maszyny na wysokie napiecie – badanie bezposrednie w mieszaninie gazowej PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","categories":["other"],"row_index":93,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected equipment of type of protection \"n\" Ignition by high-voltage machines – direct test in a gas mixture PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","search_zh":"「n」型防爆结构设备 PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","test_object_zh":"「n」型防爆结构设备"},{"_id":"6a5dc9a7f1c10c8ce8259b2e","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia budowy przeciwwybuchowej \"n\"","test_object_en":"Explosion-protected equipment of type of protection \"n\"","methodology":"Rezystancja izolacji baterii-pomiar bezpośredni rezystancji","methodology_en":"Battery insulation resistance - direct measurement of resistance","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja izolacji baterii-pomiar bezpośredni rezystancji","reference":"PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","norm_bases":["PN-EN 60079-15:2010","EN 60079-15:2010","IEC 60079-15:2010 ed.4.0","IEC 60079-15:2017 ed. 5.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia budowy przeciwwybuchowej \"n\" Rezystancja izolacji baterii-pomiar bezpośredni rezystancji PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0 Urzadzenia budowy przeciwwybuchowej \"n\" Rezystancja izolacji baterii-pomiar bezposredni rezystancji PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","categories":["construction"],"row_index":94,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Explosion-protected equipment of type of protection \"n\" Battery insulation resistance - direct measurement of resistance PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","search_zh":"「n」型防爆结构设备 PN-EN 60079-15:2010 | EN 60079-15:2010 | IEC 60079-15:2010 ed.4.0 | IEC 60079-15:2017 ed. 5.0","test_object_zh":"「n」型防爆结构设备"},{"_id":"6a5dc9a7f1c10c8ce8259b2f","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia zabezpieczone poprzez hermetyzację „m”","test_object_en":"Equipment protected by encapsulation „m”","methodology":"Absorpcja wody – pomiar masy w zakresie od 0,02 g do 500 g","methodology_en":"Water absorption – mass measurement in the range from 0,02 g to 500 g","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Absorpcja wody – pomiar masy w zakresie od 0,02 g do 500 g","reference":"PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014-12 ed. 4.0 | IEC 60079-18:2014+AMD1:2017 CSV ed.4.1","norm_bases":["PN-EN 60079-18:2011","EN 60079-18:2009","IEC 60079-18:2009+AC1:2009 ed.3.0","PN-EN 60079-18:2015-06","EN 60079-18:2015,","IEC 60079-18:2014-12 ed. 4.0","IEC 60079-18:2014+AMD1:2017 CSV ed.4.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia zabezpieczone poprzez hermetyzację „m” Absorpcja wody – pomiar masy w zakresie od 0,02 g do 500 g PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014-12 ed. 4.0 | IEC 60079-18:2014+AMD1:2017 CSV ed.4.1 Urzadzenia zabezpieczone poprzez hermetyzacje „m” Absorpcja wody – pomiar masy w zakresie od 0,02 g do 500 g PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014-12 ed. 4.0 | IEC 60079-18:2014+AMD1:2017 CSV ed.4.1","categories":["water"],"row_index":95,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Equipment protected by encapsulation „m” Water absorption – mass measurement in the range from 0,02 g to 500 g PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014-12 ed. 4.0 | IEC 60079-18:2014+AMD1:2017 CSV ed.4.1"},{"_id":"6a5dc9a7f1c10c8ce8259b30","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia zabezpieczone poprzez hermetyzację „m”","test_object_en":"Equipment protected by encapsulation „m”","methodology":"Odporność na cykl termiczny – badanie bezpośrednie poprzez oddziaływanie temperatury","methodology_en":"Resistance to thermal cycle – direct testing by temperature exposure","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na cykl termiczny – badanie bezpośrednie poprzez oddziaływanie temperatury","reference":"PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014-12 ed. 4.0 | IEC 60079-18:2014+AMD1:2017 CSV ed.4.1","norm_bases":["PN-EN 60079-18:2011","EN 60079-18:2009","IEC 60079-18:2009+AC1:2009 ed.3.0","PN-EN 60079-18:2015-06","EN 60079-18:2015,","IEC 60079-18:2014-12 ed. 4.0","IEC 60079-18:2014+AMD1:2017 CSV ed.4.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia zabezpieczone poprzez hermetyzację „m” Odporność na cykl termiczny – badanie bezpośrednie poprzez oddziaływanie temperatury PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014-12 ed. 4.0 | IEC 60079-18:2014+AMD1:2017 CSV ed.4.1 Urzadzenia zabezpieczone poprzez hermetyzacje „m” Odpornosc na cykl termiczny – badanie bezposrednie poprzez oddzialywanie temperatury PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014-12 ed. 4.0 | IEC 60079-18:2014+AMD1:2017 CSV ed.4.1","categories":["other"],"row_index":96,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Equipment protected by encapsulation „m” Resistance to thermal cycle – direct testing by temperature exposure PN-EN 60079-18:2011 | EN 60079-18:2009 | IEC 60079-18:2009+AC1:2009 ed.3.0 | PN-EN 60079-18:2015-06 | EN 60079-18:2015, | IEC 60079-18:2014-12 ed. 4.0 | IEC 60079-18:2014+AMD1:2017 CSV ed.4.1"},{"_id":"6a5dc9a7f1c10c8ce8259b31","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Urządzenia nieelektryczne w przestrzeniach zagrożonych wybuchem. Ochrona przez kontrolę źródła zapłonu \"b\"","test_object_en":"Non-electrical equipment for explosive atmospheres. Protection by control of ignition source \"b\"","methodology":"Poziom i zakres zmienności sygnałów z czujników – pomiar bezpośredni w trakcie zadawanego wymuszenia","methodology_en":"Level and range of variability of sensor signals – direct measurement during the applied excitation","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom i zakres zmienności sygnałów z czujników – pomiar bezpośredni w trakcie zadawanego wymuszenia","reference":"PN-EN ISO 80079-37:2016-07 | EN ISO 80079-37:2016 | ISO 80079-37:2016","norm_bases":["PN-EN ISO 80079-37:2016-07","EN ISO 80079-37:2016","ISO 80079-37:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia nieelektryczne w przestrzeniach zagrożonych wybuchem. Ochrona przez kontrolę źródła zapłonu \"b\" Poziom i zakres zmienności sygnałów z czujników – pomiar bezpośredni w trakcie zadawanego wymuszenia PN-EN ISO 80079-37:2016-07 | EN ISO 80079-37:2016 | ISO 80079-37:2016 Urzadzenia nieelektryczne w przestrzeniach zagrozonych wybuchem. Ochrona przez kontrole zrodla zaplonu \"b\" Poziom i zakres zmiennosci sygnalow z czujnikow – pomiar bezposredni w trakcie zadawanego wymuszenia PN-EN ISO 80079-37:2016-07 | EN ISO 80079-37:2016 | ISO 80079-37:2016","categories":["other"],"row_index":97,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Non-electrical equipment for explosive atmospheres. Protection by control of ignition source \"b\" Level and range of variability of sensor signals – direct measurement during the applied excitation PN-EN ISO 80079-37:2016-07 | EN ISO 80079-37:2016 | ISO 80079-37:2016"},{"_id":"6a5dc9a7f1c10c8ce8259b32","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Zabezpieczenie urządzeń za pomocą pomieszczeń z nadciśnieniem „p“","test_object_en":"Protection of equipment by pressurized rooms „p“","methodology":"Skuteczność przewietrzania – badanie bezpośrednie poprzez pomiary stężeń","methodology_en":"Ventilation effectiveness – direct testing by concentration measurements","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność przewietrzania – badanie bezpośrednie poprzez pomiary stężeń","reference":"PN-EN 60079-13:2011 | EN 60079-13:2010 | IEC 60079-13:2010 ed.1 | PN-EN 60079-13:2017-11 | EN 60079-13:2017 | IEC 60079-13:2017 ed. 2.0","norm_bases":["PN-EN 60079-13:2011","EN 60079-13:2010","IEC 60079-13:2010 ed.1","PN-EN 60079-13:2017-11","EN 60079-13:2017","IEC 60079-13:2017 ed. 2.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabezpieczenie urządzeń za pomocą pomieszczeń z nadciśnieniem „p“ Skuteczność przewietrzania – badanie bezpośrednie poprzez pomiary stężeń PN-EN 60079-13:2011 | EN 60079-13:2010 | IEC 60079-13:2010 ed.1 | PN-EN 60079-13:2017-11 | EN 60079-13:2017 | IEC 60079-13:2017 ed. 2.0 Zabezpieczenie urzadzen za pomoca pomieszczen z nadcisnieniem „p“ Skutecznosc przewietrzania – badanie bezposrednie poprzez pomiary stezen PN-EN 60079-13:2011 | EN 60079-13:2010 | IEC 60079-13:2010 ed.1 | PN-EN 60079-13:2017-11 | EN 60079-13:2017 | IEC 60079-13:2017 ed. 2.0","categories":["other"],"row_index":98,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Protection of equipment by pressurized rooms „p“ Ventilation effectiveness – direct testing by concentration measurements PN-EN 60079-13:2011 | EN 60079-13:2010 | IEC 60079-13:2010 ed.1 | PN-EN 60079-13:2017-11 | EN 60079-13:2017 | IEC 60079-13:2017 ed. 2.0","search_zh":"采用正压房间「p」对设备进行防护 PN-EN 60079-13:2011 | EN 60079-13:2010 | IEC 60079-13:2010 ed.1 | PN-EN 60079-13:2017-11 | EN 60079-13:2017 | IEC 60079-13:2017 ed. 2.0","test_object_zh":"采用正压房间「p」对设备进行防护"},{"_id":"6a5dc9a7f1c10c8ce8259b33","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Zabezpieczenie urządzeń za pomocą pomieszczeń z nadciśnieniem „p“","test_object_en":"Protection of equipment by pressurized rooms „p“","methodology":"Wydajność systemu przewietrzania – pomiar ciśnienia statycznego w zakresie od 25 Pa do 1 MPa","methodology_en":"Performance of the ventilation system – static pressure measurement in the range from 25 Pa to 1 MPa","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydajność systemu przewietrzania – pomiar ciśnienia statycznego w zakresie od 25 Pa do 1 MPa","reference":"PN-EN 60079-13:2011 | EN 60079-13:2010 | IEC 60079-13:2010 ed.1 | PN-EN 60079-13:2017-11 | EN 60079-13:2017 | IEC 60079-13:2017 ed. 2.0","norm_bases":["PN-EN 60079-13:2011","EN 60079-13:2010","IEC 60079-13:2010 ed.1","PN-EN 60079-13:2017-11","EN 60079-13:2017","IEC 60079-13:2017 ed. 2.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabezpieczenie urządzeń za pomocą pomieszczeń z nadciśnieniem „p“ Wydajność systemu przewietrzania – pomiar ciśnienia statycznego w zakresie od 25 Pa do 1 MPa PN-EN 60079-13:2011 | EN 60079-13:2010 | IEC 60079-13:2010 ed.1 | PN-EN 60079-13:2017-11 | EN 60079-13:2017 | IEC 60079-13:2017 ed. 2.0 Zabezpieczenie urzadzen za pomoca pomieszczen z nadcisnieniem „p“ Wydajnosc systemu przewietrzania – pomiar cisnienia statycznego w zakresie od 25 Pa do 1 MPa PN-EN 60079-13:2011 | EN 60079-13:2010 | IEC 60079-13:2010 ed.1 | PN-EN 60079-13:2017-11 | EN 60079-13:2017 | IEC 60079-13:2017 ed. 2.0","categories":["other"],"row_index":99,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Protection of equipment by pressurized rooms „p“ Performance of the ventilation system – static pressure measurement in the range from 25 Pa to 1 MPa PN-EN 60079-13:2011 | EN 60079-13:2010 | IEC 60079-13:2010 ed.1 | PN-EN 60079-13:2017-11 | EN 60079-13:2017 | IEC 60079-13:2017 ed. 2.0","search_zh":"采用正压房间「p」对设备进行防护 PN-EN 60079-13:2011 | EN 60079-13:2010 | IEC 60079-13:2010 ed.1 | PN-EN 60079-13:2017-11 | EN 60079-13:2017 | IEC 60079-13:2017 ed. 2.0","test_object_zh":"采用正压房间「p」对设备进行防护"},{"_id":"6a5dc9a7f1c10c8ce8259b34","lab_id":"69ad52a3de79e566650fb901","country":"PL","accr_number":"AB 1710","accr_body":"PCA","test_object":"Zabezpieczenie urządzeń za pomocą pomieszczeń z nadciśnieniem „p“","test_object_en":"Protection of equipment by pressurized rooms „p“","methodology":"Wydajność systemu przewietrzania – pomiar ciśnienia statycznego w zakresie od 25 Pa do 1 MPa","methodology_en":"Performance of the ventilation system – static pressure measurement in the range from 25 Pa to 1 MPa","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydajność systemu przewietrzania – pomiar ciśnienia statycznego w zakresie od 25 Pa do 1 MPa","reference":"PN-EN 60079-13:2011 | EN 60079-13:2010 | IEC 60079-13:2010 ed.1 | PN-EN 60079-13:2017-11 | EN 60079-13:2017 | IEC 60079-13:2017 ed. 2.0","norm_bases":["PN-EN 60079-13:2011","EN 60079-13:2010","IEC 60079-13:2010 ed.1","PN-EN 60079-13:2017-11","EN 60079-13:2017","IEC 60079-13:2017 ed. 2.0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabezpieczenie urządzeń za pomocą pomieszczeń z nadciśnieniem „p“ Wydajność systemu przewietrzania – pomiar ciśnienia statycznego w zakresie od 25 Pa do 1 MPa PN-EN 60079-13:2011 | EN 60079-13:2010 | IEC 60079-13:2010 ed.1 | PN-EN 60079-13:2017-11 | EN 60079-13:2017 | IEC 60079-13:2017 ed. 2.0 Zabezpieczenie urzadzen za pomoca pomieszczen z nadcisnieniem „p“ Wydajnosc systemu przewietrzania – pomiar cisnienia statycznego w zakresie od 25 Pa do 1 MPa PN-EN 60079-13:2011 | EN 60079-13:2010 | IEC 60079-13:2010 ed.1 | PN-EN 60079-13:2017-11 | EN 60079-13:2017 | IEC 60079-13:2017 ed. 2.0","categories":["other"],"row_index":100,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Protection of equipment by pressurized rooms „p“ Performance of the ventilation system – static pressure measurement in the range from 25 Pa to 1 MPa PN-EN 60079-13:2011 | EN 60079-13:2010 | IEC 60079-13:2010 ed.1 | PN-EN 60079-13:2017-11 | EN 60079-13:2017 | IEC 60079-13:2017 ed. 2.0","search_zh":"采用正压房间「p」对设备进行防护 PN-EN 60079-13:2011 | EN 60079-13:2010 | IEC 60079-13:2010 ed.1 | PN-EN 60079-13:2017-11 | EN 60079-13:2017 | IEC 60079-13:2017 ed. 2.0","test_object_zh":"采用正压房间「p」对设备进行防护"}],"has_pdf":true}