{"lab":{"_id":"69ad52a3de79e566650fb155","accr_number":"AB 171","country":"PL","accr_body":"PCA","address":"LABORATORIUM INSTYTUTU, ZESPÓŁ LABORATORIÓW BADAWCZYCH, ul. Pr. St. Wyszyńskiego 7","categories":["materials","environment","electronics"],"city":"Zielonka","imported_at":"2026-03-08T10:42:43.265Z","methods_count":133,"name":"WOJSKOWY INSTYTUT TECHNICZNY UZBROJENIA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_171.pdf"],"scope_summary":"","search_text":"wojskowy instytut techniczny uzbrojenia laboratorium instytutu, zespół laboratoriów badawczych, ul. pr. st. wyszyńskiego 7 other environment pharma electronics materials water automotive metrology food construction","status":"active","updated_at":"2026-03-08T14:50:50.248Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T11:22:40.663Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20171,podmiot.html","fields_of_testing":[{"codes":"C/4;C/52","pl":"Badania chemiczne wyrobów chemicznych, materiałów wybuchowych","en":"Chemical tests of chemical products and explosives"},{"codes":"E/6;E/15;E/53;E/54","pl":"Badania elektryczne i elektroniczne wyrobów i wyposażenia elektrycznego, wyposażenia wojskowego, wyrobów i wyposażenia telekomunikacyjnego i elektronicznego","en":"Electric and electronic tests of electrical products and equipment, military equipment, telecommunication and electronic products and equipment"},{"codes":"F/6;F/15;F/53;F/54","pl":"Badania kompatybilności elektromagnetycznej (EMC) wyrobów i wyposażenia elektrycznego, wyposażenia wojskowego, wyrobów i wyposażenia telekomunikacyjnego i elektronicznego","en":"Electromagnetic compatibility (EMC) tests of electrical products and equipment and military equipment, telecommunication and electronic products and equipment"},{"codes":"H/15;H/52","pl":"Badania ogniowe wyposażenia wojskowego, materiałów wybuchowych","en":"Fire tests of military equipment, explosives"},{"codes":"J/8;J/15;J/52","pl":"Badania mechaniczne wyrobów i materiałów konstrukcyjnych, wyposażenia wojskowego, materiałów wybuchowych","en":"Mechanical tests of construction products and materials, military equipment, explosives"}],"issue":{"no":"21","date":"13.05.2026"},"parse_date":"2026-08-17T11:22:40.663Z","parse_source":"agent-claude-code","map_coord":[52.310847,21.15232],"map_geo":"nominatim-city","lab_locations":[{"name":"LABORATORIUM INSTYTUTU","address":"ul. Pr. St. Wyszyńskiego 7","city":null,"postal":null},{"name":"ZESPÓŁ LABORATORIÓW BADAWCZYCH","address":"ul. Pr. St. Wyszyńskiego 7","city":null,"postal":null},{"name":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","address":"ul. Pr. St. Wyszyńskiego 7, 05-220 Zielonka","city":"Zielonka","postal":"05-220"},{"name":"Laboratorium Badań Sprzętu i Amunicji Artyleryjskiej, Rakiet i Zespołów Rakiet","address":"ul. Pr. St. Wyszyńskiego 7, 05-220 Zielonka","city":"Zielonka","postal":"05-220"},{"name":"Laboratorium Badań Środków Bojowych","address":"ul. Pr. St. Wyszyńskiego 7, 05-220 Zielonka","city":"Zielonka","postal":"05-220"},{"name":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","address":"ul. Pr. St. Wyszyńskiego 7, 05-220 Zielonka","city":"Zielonka","postal":"05-220"},{"name":"Laboratorium Badań Systemów Optoelektronicznych","address":"ul. Pr. St. Wyszyńskiego 7, 05-220 Zielonka","city":"Zielonka","postal":"05-220"},{"name":"Laboratorium Badań Sprzętu Uzbrojenia w Warunkach Poligonowych","address":"ul. Ofiar Katynia 63, 37-450 Stalowa Wola","city":"Stalowa Wola","postal":"37-450"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/8c223aa7d277c62646ce79559fddb504/AB%20171.pdf","has_en":true,"category_counts":{"other":76,"materials":28,"environment":19,"electronics":10,"automotive":4,"water":1},"category_scores":{"other":41.86,"materials":5.68,"environment":2.62,"electronics":0.72,"automotive":0.12,"water":0.01},"has_zh":true},"methods":[{"_id":"6a82ef00884ede9a1b2c4b40","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników","methodology":"Prędkość","parameters":[{"name":"Zakres","range":"(20 – 3000) m/s"}],"technique":null,"techniques":[],"computed":[],"activity":"Prędkość\nZakres (20 – 3000) m/s","reference":"NO-13-A230:2005 NO-13-A230/A1:2015 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A1:2010 NO-13-A504-2/A2:2019 NO-13-A509:2003 NO-13-A509/A1:2014 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.14 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.15 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024","norm_bases":["NO-13-A230:2005 NO-13-A230/A1:2015 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A1:2010 NO-13-A504-2/A2:2019 NO-13-A509:2003 NO-13-A509/A1:2014","STANAG 4172 ED 2","STANAG 2310 ED 3","STANAG 4090 ED 2","STANAG 4383 ED 1 Procedura LBUSO.PB.14 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.15 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników Prędkość\nZakres (20 – 3000) m/s NO-13-A230:2005 NO-13-A230/A1:2015 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A1:2010 NO-13-A504-2/A2:2019 NO-13-A509:2003 NO-13-A509/A1:2014 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.14 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.15 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024 Amunicja strzelecka, lotnicza, artyleryjska, odlamki oraz granaty nasadkowe i naboje do granatnikow Predkosc\nZakres (20 – 3000) m/s NO-13-A230:2005 NO-13-A230/A1:2015 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A1:2010 NO-13-A504-2/A2:2019 NO-13-A509:2003 NO-13-A509/A1:2014 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.14 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.15 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Velocity","parameters_en":[{"name":"Range","range":"(20 – 3000) m/s"}],"search_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges Velocity Range NO-13-A230:2005 NO-13-A230/A1:2015 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A1:2010 NO-13-A504-2/A2:2019 NO-13-A509:2003 NO-13-A509/A1:2014 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.14 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.15 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024","test_object_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges","parameters_zh":[{"name":"范围","range":"(20 – 3000) m/s"}],"search_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药 速度 范围 NO-13-A230:2005 NO-13-A230/A1:2015 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A1:2010 NO-13-A504-2/A2:2019 NO-13-A509:2003 NO-13-A509/A1:2014 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.14 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.15 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024","methodology_zh":"速度","test_object_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药"},{"_id":"6a82ef00884ede9a1b2c4b41","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników","methodology":"Ciśnienie gazów prochowych w przewodzie lufy","parameters":[{"name":"Zakres","range":"do 500 MPa"},{"name":"Zakres","range":"do 600 MPa"}],"technique":"Metoda zgniotkowa; Metoda piezoelektryczna","techniques":["Metoda zgniotkowa","Metoda piezoelektryczna"],"computed":[],"activity":"Ciśnienie gazów prochowych w przewodzie lufy\nZakres:\nZakres do 500 MPa\nZakres do 600 MPa\nMetoda zgniotkowa; Metoda piezoelektryczna","reference":"NO-13-A229:2015 NO-13-A510:2007 NO-13-A219:2014 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A2:2019 NO-13-A504-3:2019 NO-13-A509:2003 NO-13-A509/A1:2014 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.02 Edycja 4 z dnia 06.03.2020 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024 Procedura LBUSO.PB.20 Edycja 3 z dnia 06.03.2020","norm_bases":["NO-13-A229:2015 NO-13-A510:2007 NO-13-A219:2014 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A2:2019 NO-13-A504-3:2019 NO-13-A509:2003 NO-13-A509/A1:2014","STANAG 4172 ED 2","STANAG 2310 ED 3","STANAG 4090 ED 2","STANAG 4383 ED 1 Procedura LBUSO.PB.02 Edycja 4 z dnia 06.03.2020 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024 Procedura LBUSO.PB.20 Edycja 3 z dnia 06.03.2020"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników Ciśnienie gazów prochowych w przewodzie lufy\nZakres:\nZakres do 500 MPa\nZakres do 600 MPa\nMetoda zgniotkowa; Metoda piezoelektryczna NO-13-A229:2015 NO-13-A510:2007 NO-13-A219:2014 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A2:2019 NO-13-A504-3:2019 NO-13-A509:2003 NO-13-A509/A1:2014 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.02 Edycja 4 z dnia 06.03.2020 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024 Procedura LBUSO.PB.20 Edycja 3 z dnia 06.03.2020 Amunicja strzelecka, lotnicza, artyleryjska, odlamki oraz granaty nasadkowe i naboje do granatnikow Cisnienie gazow prochowych w przewodzie lufy\nZakres:\nZakres do 500 MPa\nZakres do 600 MPa\nMetoda zgniotkowa; Metoda piezoelektryczna NO-13-A229:2015 NO-13-A510:2007 NO-13-A219:2014 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A2:2019 NO-13-A504-3:2019 NO-13-A509:2003 NO-13-A509/A1:2014 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.02 Edycja 4 z dnia 06.03.2020 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024 Procedura LBUSO.PB.20 Edycja 3 z dnia 06.03.2020","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Propellant gas pressure in the barrel bore","parameters_en":[{"name":"Range","range":"do 500 MPa"},{"name":"Range","range":"do 600 MPa"}],"search_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges Propellant gas pressure in the barrel bore Crusher gauge method; Piezoelectric method Range Range NO-13-A229:2015 NO-13-A510:2007 NO-13-A219:2014 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A2:2019 NO-13-A504-3:2019 NO-13-A509:2003 NO-13-A509/A1:2014 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.02 Edycja 4 z dnia 06.03.2020 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024 Procedura LBUSO.PB.20 Edycja 3 z dnia 06.03.2020","technique_en":"Crusher gauge method; Piezoelectric method","test_object_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges","parameters_zh":[{"name":"范围","range":"do 500 MPa"},{"name":"范围","range":"do 600 MPa"}],"search_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药 范围 范围 NO-13-A229:2015 NO-13-A510:2007 NO-13-A219:2014 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A2:2019 NO-13-A504-3:2019 NO-13-A509:2003 NO-13-A509/A1:2014 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.02 Edycja 4 z dnia 06.03.2020 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024 Procedura LBUSO.PB.20 Edycja 3 z dnia 06.03.2020","test_object_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药"},{"_id":"6a82ef00884ede9a1b2c4b42","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników","methodology":"Skupienie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skupienie","reference":"NO-13-A229:2015 NO-13-A510:2007 NO-13-A219:2014 NO-13-A501:2009 NO-13-A502:2009 NO-13-A507:2001 NO-13-A507/A1:2017 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A2:2019 NO-13-A504-3:2019 NO-13-A509:2003 NO-13-A509:2003/A1:2014 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.03 Edycja 4 z dnia 06.03.2020","norm_bases":["NO-13-A229:2015 NO-13-A510:2007 NO-13-A219:2014 NO-13-A501:2009 NO-13-A502:2009 NO-13-A507:2001 NO-13-A507/A1:2017 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A2:2019 NO-13-A504-3:2019 NO-13-A509:2003 NO-13-A509:2003/A1:2014","STANAG 4172 ED 2","STANAG 2310 ED 3","STANAG 4090 ED 2","STANAG 4383 ED 1 Procedura LBUSO.PB.03 Edycja 4 z dnia 06.03.2020"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników Skupienie NO-13-A229:2015 NO-13-A510:2007 NO-13-A219:2014 NO-13-A501:2009 NO-13-A502:2009 NO-13-A507:2001 NO-13-A507/A1:2017 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A2:2019 NO-13-A504-3:2019 NO-13-A509:2003 NO-13-A509:2003/A1:2014 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.03 Edycja 4 z dnia 06.03.2020 Amunicja strzelecka, lotnicza, artyleryjska, odlamki oraz granaty nasadkowe i naboje do granatnikow Skupienie NO-13-A229:2015 NO-13-A510:2007 NO-13-A219:2014 NO-13-A501:2009 NO-13-A502:2009 NO-13-A507:2001 NO-13-A507/A1:2017 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A2:2019 NO-13-A504-3:2019 NO-13-A509:2003 NO-13-A509:2003/A1:2014 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.03 Edycja 4 z dnia 06.03.2020","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Grouping","search_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges Grouping NO-13-A229:2015 NO-13-A510:2007 NO-13-A219:2014 NO-13-A501:2009 NO-13-A502:2009 NO-13-A507:2001 NO-13-A507/A1:2017 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A2:2019 NO-13-A504-3:2019 NO-13-A509:2003 NO-13-A509:2003/A1:2014 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.03 Edycja 4 z dnia 06.03.2020","test_object_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges","search_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药 NO-13-A229:2015 NO-13-A510:2007 NO-13-A219:2014 NO-13-A501:2009 NO-13-A502:2009 NO-13-A507:2001 NO-13-A507/A1:2017 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A2:2019 NO-13-A504-3:2019 NO-13-A509:2003 NO-13-A509:2003/A1:2014 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.03 Edycja 4 z dnia 06.03.2020","test_object_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药"},{"_id":"6a82ef00884ede9a1b2c4b43","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników","methodology":"Niezawodność działania amunicji i wytrzymałość łusek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Niezawodność działania amunicji i wytrzymałość łusek","reference":"NO-13-A229:2015 NO-13-A510:2007 NO-13-A219:2014 NO-13-A507:2001 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504:2000 NO-13-A509:2003 NO-13-A509/A1:2014 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.33 Edycja 2 z dnia 06.03.2020 Procedura LBUSO.PB.38 Edycja 1 z dnia 10.01.2024","norm_bases":["NO-13-A229:2015 NO-13-A510:2007 NO-13-A219:2014 NO-13-A507:2001 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504:2000 NO-13-A509:2003 NO-13-A509/A1:2014","STANAG 4172 ED 2","STANAG 2310 ED 3","STANAG 4090 ED 2","STANAG 4383 ED 1 Procedura LBUSO.PB.33 Edycja 2 z dnia 06.03.2020 Procedura LBUSO.PB.38 Edycja 1 z dnia 10.01.2024"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników Niezawodność działania amunicji i wytrzymałość łusek NO-13-A229:2015 NO-13-A510:2007 NO-13-A219:2014 NO-13-A507:2001 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504:2000 NO-13-A509:2003 NO-13-A509/A1:2014 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.33 Edycja 2 z dnia 06.03.2020 Procedura LBUSO.PB.38 Edycja 1 z dnia 10.01.2024 Amunicja strzelecka, lotnicza, artyleryjska, odlamki oraz granaty nasadkowe i naboje do granatnikow Niezawodnosc dzialania amunicji i wytrzymalosc lusek NO-13-A229:2015 NO-13-A510:2007 NO-13-A219:2014 NO-13-A507:2001 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504:2000 NO-13-A509:2003 NO-13-A509/A1:2014 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.33 Edycja 2 z dnia 06.03.2020 Procedura LBUSO.PB.38 Edycja 1 z dnia 10.01.2024","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Operational reliability of ammunition and strength of cartridge cases","search_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges Operational reliability of ammunition and strength of cartridge cases NO-13-A229:2015 NO-13-A510:2007 NO-13-A219:2014 NO-13-A507:2001 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504:2000 NO-13-A509:2003 NO-13-A509/A1:2014 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.33 Edycja 2 z dnia 06.03.2020 Procedura LBUSO.PB.38 Edycja 1 z dnia 10.01.2024","test_object_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges","search_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药 NO-13-A229:2015 NO-13-A510:2007 NO-13-A219:2014 NO-13-A507:2001 NO-13-A224:2013 NO-13-A225:2013 NO-13-A504:2000 NO-13-A509:2003 NO-13-A509/A1:2014 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.33 Edycja 2 z dnia 06.03.2020 Procedura LBUSO.PB.38 Edycja 1 z dnia 10.01.2024","test_object_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药"},{"_id":"6a82ef00884ede9a1b2c4b44","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników","methodology":"Wrażliwość środków bojowych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wrażliwość środków bojowych","reference":"Procedura LBUSO.PB.34 Edycja 1 z dnia 06.03.2020","norm_bases":["Procedura LBUSO.PB.34 Edycja 1 z dnia 06.03.2020"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników Wrażliwość środków bojowych Procedura LBUSO.PB.34 Edycja 1 z dnia 06.03.2020 Amunicja strzelecka, lotnicza, artyleryjska, odlamki oraz granaty nasadkowe i naboje do granatnikow Wrazliwosc srodkow bojowych Procedura LBUSO.PB.34 Edycja 1 z dnia 06.03.2020","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sensitivity of munitions","search_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges Sensitivity of munitions Procedura LBUSO.PB.34 Edycja 1 z dnia 06.03.2020","test_object_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges","search_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药 Procedura LBUSO.PB.34 Edycja 1 z dnia 06.03.2020","test_object_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药"},{"_id":"6a82ef00884ede9a1b2c4b45","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników","methodology":"Wrażliwość spłonek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wrażliwość spłonek","reference":"Procedura LBUSO.PB.35 Edycja 2 z dnia 15.11.2021","norm_bases":["Procedura LBUSO.PB.35 Edycja 2 z dnia 15.11.2021"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników Wrażliwość spłonek Procedura LBUSO.PB.35 Edycja 2 z dnia 15.11.2021 Amunicja strzelecka, lotnicza, artyleryjska, odlamki oraz granaty nasadkowe i naboje do granatnikow Wrazliwosc splonek Procedura LBUSO.PB.35 Edycja 2 z dnia 15.11.2021","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sensitivity of primers","search_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges Sensitivity of primers Procedura LBUSO.PB.35 Edycja 2 z dnia 15.11.2021","test_object_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges","search_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药 Procedura LBUSO.PB.35 Edycja 2 z dnia 15.11.2021","test_object_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药"},{"_id":"6a82ef00884ede9a1b2c4b46","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników","methodology":"Graniczny kąt rykoszetowania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Graniczny kąt rykoszetowania","reference":"Procedura LBUSO.PB.31 Edycja 3 z dnia 06.03.2020","norm_bases":["Procedura LBUSO.PB.31 Edycja 3 z dnia 06.03.2020"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników Graniczny kąt rykoszetowania Procedura LBUSO.PB.31 Edycja 3 z dnia 06.03.2020 Amunicja strzelecka, lotnicza, artyleryjska, odlamki oraz granaty nasadkowe i naboje do granatnikow Graniczny kat rykoszetowania Procedura LBUSO.PB.31 Edycja 3 z dnia 06.03.2020","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Limiting ricochet angle","search_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges Limiting ricochet angle Procedura LBUSO.PB.31 Edycja 3 z dnia 06.03.2020","test_object_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges","search_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药 Procedura LBUSO.PB.31 Edycja 3 z dnia 06.03.2020","test_object_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药"},{"_id":"6a82ef00884ede9a1b2c4b47","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników","methodology":"Odporność na czynniki środowiskowe","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na czynniki środowiskowe","reference":"Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","norm_bases":["Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników Odporność na czynniki środowiskowe Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024 Amunicja strzelecka, lotnicza, artyleryjska, odlamki oraz granaty nasadkowe i naboje do granatnikow Odpornosc na czynniki srodowiskowe Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to environmental factors","search_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges Resistance to environmental factors Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","test_object_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges","search_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药 耐环境因素性 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","test_object_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药","methodology_zh":"耐环境因素性"},{"_id":"6a82ef00884ede9a1b2c4b48","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników","methodology":"Parametry fizyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Parametry fizyczne","reference":"Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022","norm_bases":["Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników Parametry fizyczne Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022 Amunicja strzelecka, lotnicza, artyleryjska, odlamki oraz granaty nasadkowe i naboje do granatnikow Parametry fizyczne Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Physical parameters","search_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges Physical parameters Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022","test_object_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges","search_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药 物理参数 Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022","test_object_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药","methodology_zh":"物理参数"},{"_id":"6a82ef00884ede9a1b2c4b49","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników","methodology":"Zgodność z dokumentacją - jakość znakowania i ukompletowania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zgodność z dokumentacją - jakość znakowania i ukompletowania","reference":"Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024 NO-A-STANAG-2953/AOP-2","norm_bases":["Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024 NO-A-STANAG-2953/AOP-2"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników Zgodność z dokumentacją - jakość znakowania i ukompletowania Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024 NO-A-STANAG-2953/AOP-2 Amunicja strzelecka, lotnicza, artyleryjska, odlamki oraz granaty nasadkowe i naboje do granatnikow Zgodnosc z dokumentacja - jakosc znakowania i ukompletowania Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024 NO-A-STANAG-2953/AOP-2","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Conformity with documentation - quality of marking and completeness","search_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges Conformity with documentation - quality of marking and completeness Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024 NO-A-STANAG-2953/AOP-2","test_object_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges","search_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药 与文件的符合性 － 标识与配套的质量 Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024 NO-A-STANAG-2953/AOP-2","test_object_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药","methodology_zh":"与文件的符合性 － 标识与配套的质量"},{"_id":"6a82ef00884ede9a1b2c4b4a","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników","methodology":"Siła rozcalania pocisku","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Siła rozcalania pocisku","reference":"NO-13-A229:2015 NO-13-A510:2007 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024 Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022","norm_bases":["NO-13-A229:2015 NO-13-A510:2007","STANAG 4172 ED 2","STANAG 2310 ED 3","STANAG 4090 ED 2","STANAG 4383 ED 1 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024 Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników Siła rozcalania pocisku NO-13-A229:2015 NO-13-A510:2007 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024 Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022 Amunicja strzelecka, lotnicza, artyleryjska, odlamki oraz granaty nasadkowe i naboje do granatnikow Sila rozcalania pocisku NO-13-A229:2015 NO-13-A510:2007 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024 Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bullet extraction force","search_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges Bullet extraction force NO-13-A229:2015 NO-13-A510:2007 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024 Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022","test_object_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges","search_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药 NO-13-A229:2015 NO-13-A510:2007 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024 Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022","test_object_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药"},{"_id":"6a82ef00884ede9a1b2c4b4b","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników","methodology":"Czas balistyczny (action time)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Czas balistyczny (action time)","reference":"NO-13-A229:2015 NO-13-A510:2007 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.36 Edycja 1 z dnia 10.01.2024 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024","norm_bases":["NO-13-A229:2015 NO-13-A510:2007","STANAG 4172 ED 2","STANAG 2310 ED 3","STANAG 4090 ED 2","STANAG 4383 ED 1 Procedura LBUSO.PB.36 Edycja 1 z dnia 10.01.2024 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników Czas balistyczny (action time) NO-13-A229:2015 NO-13-A510:2007 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.36 Edycja 1 z dnia 10.01.2024 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024 Amunicja strzelecka, lotnicza, artyleryjska, odlamki oraz granaty nasadkowe i naboje do granatnikow Czas balistyczny (action time) NO-13-A229:2015 NO-13-A510:2007 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.36 Edycja 1 z dnia 10.01.2024 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024","categories":["other"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ballistic time (action time)","search_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges Ballistic time (action time) NO-13-A229:2015 NO-13-A510:2007 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.36 Edycja 1 z dnia 10.01.2024 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024","test_object_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges","search_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药 NO-13-A229:2015 NO-13-A510:2007 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.36 Edycja 1 z dnia 10.01.2024 Procedura LBUSO.PB.04 Edycja 8 z dnia 10.01.2024","test_object_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药"},{"_id":"6a82ef00884ede9a1b2c4b4c","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników","methodology":"Energia kinetyczna pocisków","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Energia kinetyczna pocisków","reference":"NO-13-A230:2005 NO-13-A230/A1:2015 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A1:2010 NO-13-A504-2/A2:2019 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.14 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.15 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022 Procedura LBUSO.PB.37 Edycja 1 z dnia 10.01.2024","norm_bases":["NO-13-A230:2005 NO-13-A230/A1:2015 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A1:2010 NO-13-A504-2/A2:2019","STANAG 4172 ED 2","STANAG 2310 ED 3","STANAG 4090 ED 2","STANAG 4383 ED 1 Procedura LBUSO.PB.14 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.15 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022 Procedura LBUSO.PB.37 Edycja 1 z dnia 10.01.2024"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Amunicja strzelecka, lotnicza, artyleryjska, odłamki oraz granaty nasadkowe i naboje do granatników Energia kinetyczna pocisków NO-13-A230:2005 NO-13-A230/A1:2015 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A1:2010 NO-13-A504-2/A2:2019 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.14 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.15 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022 Procedura LBUSO.PB.37 Edycja 1 z dnia 10.01.2024 Amunicja strzelecka, lotnicza, artyleryjska, odlamki oraz granaty nasadkowe i naboje do granatnikow Energia kinetyczna pociskow NO-13-A230:2005 NO-13-A230/A1:2015 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A1:2010 NO-13-A504-2/A2:2019 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.14 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.15 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022 Procedura LBUSO.PB.37 Edycja 1 z dnia 10.01.2024","categories":["other"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kinetic energy of projectiles","search_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges Kinetic energy of projectiles NO-13-A230:2005 NO-13-A230/A1:2015 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A1:2010 NO-13-A504-2/A2:2019 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.14 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.15 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022 Procedura LBUSO.PB.37 Edycja 1 z dnia 10.01.2024","test_object_en":"Small arms, aircraft and artillery ammunition, fragments as well as rifle grenades and grenade launcher cartridges","search_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药 NO-13-A230:2005 NO-13-A230/A1:2015 NO-13-A504-1:2000 NO-13-A504-2:2000 NO-13-A504-2/A1:2010 NO-13-A504-2/A2:2019 | STANAG 4172 ED 2 | STANAG 2310 ED 3 | STANAG 4090 ED 2 | STANAG 4383 ED 1 Procedura LBUSO.PB.14 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.15 Edycja 4 z dnia 04.04.2022 Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022 Procedura LBUSO.PB.37 Edycja 1 z dnia 10.01.2024","test_object_zh":"枪弹、航空弹药、火炮弹药、破片以及枪挂榴弹与榴弹发射器弹药"},{"_id":"6a82ef00884ede9a1b2c4b4d","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Szyby, okna, drzwi, żaluzje, zasłony","methodology":"Kuloodporność","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kuloodporność","reference":"PN-EN 1063:2002 | PN-EN 1522:2000 | PN-EN 1523:2000 | STANAG 4569 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 VPAM APR 2006 Edycja 12.05.2010","norm_bases":["PN-EN 1063:2002","PN-EN 1522:2000","PN-EN 1523:2000","STANAG 4569 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 VPAM APR 2006 Edycja 12.05.2010"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Szyby, okna, drzwi, żaluzje, zasłony Kuloodporność PN-EN 1063:2002 | PN-EN 1522:2000 | PN-EN 1523:2000 | STANAG 4569 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 VPAM APR 2006 Edycja 12.05.2010 Szyby, okna, drzwi, zaluzje, zaslony Kuloodpornosc PN-EN 1063:2002 | PN-EN 1522:2000 | PN-EN 1523:2000 | STANAG 4569 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 VPAM APR 2006 Edycja 12.05.2010","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bullet resistance","search_en":"Glazing, windows, doors, shutters, blinds Bullet resistance PN-EN 1063:2002 | PN-EN 1522:2000 | PN-EN 1523:2000 | STANAG 4569 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 VPAM APR 2006 Edycja 12.05.2010","test_object_en":"Glazing, windows, doors, shutters, blinds","methodology_zh":"防弹性","search_zh":"防弹性 PN-EN 1063:2002 | PN-EN 1522:2000 | PN-EN 1523:2000 | STANAG 4569 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 VPAM APR 2006 Edycja 12.05.2010"},{"_id":"6a82ef00884ede9a1b2c4b4e","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Kamizelki i ubiory ochronne, Osłony osobiste, Tarcze ochronne","methodology":"Kuloodporność","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kuloodporność","reference":"PN-V-87000:1999 | PN-V-87000:2011 | PN-EN 1522:2000 | PN-EN 1523:2000 NIJ Standard – 0101.04 NIJ Standard – 0101.06 NIJ Standard – 0108.01 | STANAG 2920 GOST R 50744-95 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","norm_bases":["PN-V-87000:1999","PN-V-87000:2011","PN-EN 1522:2000","PN-EN 1523:2000 NIJ Standard – 0101.04 NIJ Standard – 0101.06 NIJ Standard – 0108.01","STANAG 2920 GOST R 50744-95 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kamizelki i ubiory ochronne, Osłony osobiste, Tarcze ochronne Kuloodporność PN-V-87000:1999 | PN-V-87000:2011 | PN-EN 1522:2000 | PN-EN 1523:2000 NIJ Standard – 0101.04 NIJ Standard – 0101.06 NIJ Standard – 0108.01 | STANAG 2920 GOST R 50744-95 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024 Kamizelki i ubiory ochronne, Oslony osobiste, Tarcze ochronne Kuloodpornosc PN-V-87000:1999 | PN-V-87000:2011 | PN-EN 1522:2000 | PN-EN 1523:2000 NIJ Standard – 0101.04 NIJ Standard – 0101.06 NIJ Standard – 0108.01 | STANAG 2920 GOST R 50744-95 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","categories":["other"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bullet resistance","search_en":"Protective vests and clothing, Personal shields, Protective shields Bullet resistance PN-V-87000:1999 | PN-V-87000:2011 | PN-EN 1522:2000 | PN-EN 1523:2000 NIJ Standard – 0101.04 NIJ Standard – 0101.06 NIJ Standard – 0108.01 | STANAG 2920 GOST R 50744-95 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","test_object_en":"Protective vests and clothing, Personal shields, Protective shields","methodology_zh":"防弹性","search_zh":"防护背心与防护服、单兵护具、防护盾牌 防弹性 PN-V-87000:1999 | PN-V-87000:2011 | PN-EN 1522:2000 | PN-EN 1523:2000 NIJ Standard – 0101.04 NIJ Standard – 0101.06 NIJ Standard – 0108.01 | STANAG 2920 GOST R 50744-95 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","test_object_zh":"防护背心与防护服、单兵护具、防护盾牌"},{"_id":"6a82ef00884ede9a1b2c4b4f","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Kamizelki i ubiory ochronne, Osłony osobiste, Tarcze ochronne","methodology":"Odłamkoodporność","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odłamkoodporność","reference":"PN-V-87000:1999 | PN-V-87000:2011 | STANAG 2920 | STANAG 4569 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","norm_bases":["PN-V-87000:1999","PN-V-87000:2011","STANAG 2920","STANAG 4569 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kamizelki i ubiory ochronne, Osłony osobiste, Tarcze ochronne Odłamkoodporność PN-V-87000:1999 | PN-V-87000:2011 | STANAG 2920 | STANAG 4569 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024 Kamizelki i ubiory ochronne, Oslony osobiste, Tarcze ochronne Odlamkoodpornosc PN-V-87000:1999 | PN-V-87000:2011 | STANAG 2920 | STANAG 4569 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","categories":["other"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fragment resistance","search_en":"Protective vests and clothing, Personal shields, Protective shields Fragment resistance PN-V-87000:1999 | PN-V-87000:2011 | STANAG 2920 | STANAG 4569 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","test_object_en":"Protective vests and clothing, Personal shields, Protective shields","methodology_zh":"抗破片性","search_zh":"防护背心与防护服、单兵护具、防护盾牌 抗破片性 PN-V-87000:1999 | PN-V-87000:2011 | STANAG 2920 | STANAG 4569 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","test_object_zh":"防护背心与防护服、单兵护具、防护盾牌"},{"_id":"6a82ef00884ede9a1b2c4b50","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Kamizelki i ubiory ochronne, Osłony osobiste, Tarcze ochronne","methodology":"Odporność na uderzenia","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na uderzenia","reference":"Procedura LBUSO.PB.24 Edycja 2 z dnia 28.02.2023","norm_bases":["Procedura LBUSO.PB.24 Edycja 2 z dnia 28.02.2023"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kamizelki i ubiory ochronne, Osłony osobiste, Tarcze ochronne Odporność na uderzenia Procedura LBUSO.PB.24 Edycja 2 z dnia 28.02.2023 Kamizelki i ubiory ochronne, Oslony osobiste, Tarcze ochronne Odpornosc na uderzenia Procedura LBUSO.PB.24 Edycja 2 z dnia 28.02.2023","categories":["other"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impact resistance","search_en":"Protective vests and clothing, Personal shields, Protective shields Impact resistance Procedura LBUSO.PB.24 Edycja 2 z dnia 28.02.2023","test_object_en":"Protective vests and clothing, Personal shields, Protective shields","methodology_zh":"耐冲击性","search_zh":"防护背心与防护服、单兵护具、防护盾牌 耐冲击性 Procedura LBUSO.PB.24 Edycja 2 z dnia 28.02.2023","test_object_zh":"防护背心与防护服、单兵护具、防护盾牌"},{"_id":"6a82ef00884ede9a1b2c4b51","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Kamizelki i ubiory ochronne, Osłony osobiste, Tarcze ochronne","methodology":"Parametry fizyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Parametry fizyczne","reference":"Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022","norm_bases":["Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kamizelki i ubiory ochronne, Osłony osobiste, Tarcze ochronne Parametry fizyczne Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022 Kamizelki i ubiory ochronne, Oslony osobiste, Tarcze ochronne Parametry fizyczne Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022","categories":["other"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Physical parameters","search_en":"Protective vests and clothing, Personal shields, Protective shields Physical parameters Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022","test_object_en":"Protective vests and clothing, Personal shields, Protective shields","search_zh":"防护背心与防护服、单兵护具、防护盾牌 物理参数 Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022","test_object_zh":"防护背心与防护服、单兵护具、防护盾牌","methodology_zh":"物理参数"},{"_id":"6a82ef00884ede9a1b2c4b52","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Kamizelki i ubiory ochronne, Osłony osobiste, Tarcze ochronne","methodology":"Odporność na czynniki środowiskowe","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na czynniki środowiskowe","reference":"Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","norm_bases":["Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kamizelki i ubiory ochronne, Osłony osobiste, Tarcze ochronne Odporność na czynniki środowiskowe Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024 Kamizelki i ubiory ochronne, Oslony osobiste, Tarcze ochronne Odpornosc na czynniki srodowiskowe Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to environmental factors","search_en":"Protective vests and clothing, Personal shields, Protective shields Resistance to environmental factors Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","test_object_en":"Protective vests and clothing, Personal shields, Protective shields","search_zh":"防护背心与防护服、单兵护具、防护盾牌 耐环境因素性 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","test_object_zh":"防护背心与防护服、单兵护具、防护盾牌","methodology_zh":"耐环境因素性"},{"_id":"6a82ef00884ede9a1b2c4b53","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Kamizelki i ubiory ochronne, Osłony osobiste, Tarcze ochronne","methodology":"Zgodność z dokumentacją - jakość znakowania i ukompletowania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zgodność z dokumentacją - jakość znakowania i ukompletowania","reference":"Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024","norm_bases":["Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kamizelki i ubiory ochronne, Osłony osobiste, Tarcze ochronne Zgodność z dokumentacją - jakość znakowania i ukompletowania Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024 Kamizelki i ubiory ochronne, Oslony osobiste, Tarcze ochronne Zgodnosc z dokumentacja - jakosc znakowania i ukompletowania Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024","categories":["other"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Conformity with documentation - quality of marking and completeness","search_en":"Protective vests and clothing, Personal shields, Protective shields Conformity with documentation - quality of marking and completeness Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024","test_object_en":"Protective vests and clothing, Personal shields, Protective shields","search_zh":"防护背心与防护服、单兵护具、防护盾牌 与文件的符合性 － 标识与配套的质量 Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024","test_object_zh":"防护背心与防护服、单兵护具、防护盾牌","methodology_zh":"与文件的符合性 － 标识与配套的质量"},{"_id":"6a82ef00884ede9a1b2c4b54","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Hełmy, Kaski, Osłony twarzy","methodology":"Kuloodporność","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kuloodporność","reference":"PN-V-87001:1999 | PN-V-87001:2011 | STANAG 2920 NIJ Standard 0106.01 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024","norm_bases":["PN-V-87001:1999","PN-V-87001:2011","STANAG 2920 NIJ Standard 0106.01 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hełmy, Kaski, Osłony twarzy Kuloodporność PN-V-87001:1999 | PN-V-87001:2011 | STANAG 2920 NIJ Standard 0106.01 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 Helmy, Kaski, Oslony twarzy Kuloodpornosc PN-V-87001:1999 | PN-V-87001:2011 | STANAG 2920 NIJ Standard 0106.01 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024","categories":["other"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bullet resistance","search_en":"Helmets, Hard hats, Face shields Bullet resistance PN-V-87001:1999 | PN-V-87001:2011 | STANAG 2920 NIJ Standard 0106.01 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024","test_object_en":"Helmets, Hard hats, Face shields","methodology_zh":"防弹性","search_zh":"头盔、防护帽、面屏 防弹性 PN-V-87001:1999 | PN-V-87001:2011 | STANAG 2920 NIJ Standard 0106.01 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024","test_object_zh":"头盔、防护帽、面屏"},{"_id":"6a82ef00884ede9a1b2c4b55","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Hełmy, Kaski, Osłony twarzy","methodology":"Odłamkoodporność","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odłamkoodporność","reference":"PN-V-87001:1999 | PN-V-87001:2011 | STANAG 2920 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","norm_bases":["PN-V-87001:1999","PN-V-87001:2011","STANAG 2920 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hełmy, Kaski, Osłony twarzy Odłamkoodporność PN-V-87001:1999 | PN-V-87001:2011 | STANAG 2920 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024 Helmy, Kaski, Oslony twarzy Odlamkoodpornosc PN-V-87001:1999 | PN-V-87001:2011 | STANAG 2920 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fragment resistance","search_en":"Helmets, Hard hats, Face shields Fragment resistance PN-V-87001:1999 | PN-V-87001:2011 | STANAG 2920 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","test_object_en":"Helmets, Hard hats, Face shields","methodology_zh":"抗破片性","search_zh":"头盔、防护帽、面屏 抗破片性 PN-V-87001:1999 | PN-V-87001:2011 | STANAG 2920 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","test_object_zh":"头盔、防护帽、面屏"},{"_id":"6a82ef00884ede9a1b2c4b56","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Hełmy, Kaski, Osłony twarzy","methodology":"Odporność na uderzenia","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na uderzenia","reference":"PN-EN 13087-3:2003 Procedura LBUSO.PB.23 Edycja 3 z dnia 10.01.2024","norm_bases":["PN-EN 13087-3:2003 Procedura LBUSO.PB.23 Edycja 3 z dnia 10.01.2024"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hełmy, Kaski, Osłony twarzy Odporność na uderzenia PN-EN 13087-3:2003 Procedura LBUSO.PB.23 Edycja 3 z dnia 10.01.2024 Helmy, Kaski, Oslony twarzy Odpornosc na uderzenia PN-EN 13087-3:2003 Procedura LBUSO.PB.23 Edycja 3 z dnia 10.01.2024","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impact resistance","search_en":"Helmets, Hard hats, Face shields Impact resistance PN-EN 13087-3:2003 Procedura LBUSO.PB.23 Edycja 3 z dnia 10.01.2024","test_object_en":"Helmets, Hard hats, Face shields","methodology_zh":"耐冲击性","search_zh":"头盔、防护帽、面屏 耐冲击性 PN-EN 13087-3:2003 Procedura LBUSO.PB.23 Edycja 3 z dnia 10.01.2024","test_object_zh":"头盔、防护帽、面屏"},{"_id":"6a82ef00884ede9a1b2c4b57","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Hełmy, Kaski, Osłony twarzy","methodology":"Parametry fizyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Parametry fizyczne","reference":"Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022","norm_bases":["Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hełmy, Kaski, Osłony twarzy Parametry fizyczne Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022 Helmy, Kaski, Oslony twarzy Parametry fizyczne Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Physical parameters","search_en":"Helmets, Hard hats, Face shields Physical parameters Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022","test_object_en":"Helmets, Hard hats, Face shields","search_zh":"头盔、防护帽、面屏 物理参数 Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022","test_object_zh":"头盔、防护帽、面屏","methodology_zh":"物理参数"},{"_id":"6a82ef00884ede9a1b2c4b58","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Hełmy, Kaski, Osłony twarzy","methodology":"Odporność na czynniki środowiskowe","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na czynniki środowiskowe","reference":"Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","norm_bases":["Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hełmy, Kaski, Osłony twarzy Odporność na czynniki środowiskowe Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024 Helmy, Kaski, Oslony twarzy Odpornosc na czynniki srodowiskowe Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to environmental factors","search_en":"Helmets, Hard hats, Face shields Resistance to environmental factors Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","test_object_en":"Helmets, Hard hats, Face shields","search_zh":"头盔、防护帽、面屏 耐环境因素性 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","test_object_zh":"头盔、防护帽、面屏","methodology_zh":"耐环境因素性"},{"_id":"6a82ef00884ede9a1b2c4b59","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Hełmy, Kaski, Osłony twarzy","methodology":"Zgodność z dokumentacją - jakość znakowania i ukompletowania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zgodność z dokumentacją - jakość znakowania i ukompletowania","reference":"Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024","norm_bases":["Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Hełmy, Kaski, Osłony twarzy Zgodność z dokumentacją - jakość znakowania i ukompletowania Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024 Helmy, Kaski, Oslony twarzy Zgodnosc z dokumentacja - jakosc znakowania i ukompletowania Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024","categories":["other"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Conformity with documentation - quality of marking and completeness","search_en":"Helmets, Hard hats, Face shields Conformity with documentation - quality of marking and completeness Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024","test_object_en":"Helmets, Hard hats, Face shields","search_zh":"头盔、防护帽、面屏 与文件的符合性 － 标识与配套的质量 Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024","test_object_zh":"头盔、防护帽、面屏","methodology_zh":"与文件的符合性 － 标识与配套的质量"},{"_id":"6a82ef00884ede9a1b2c4b5a","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Pojazdy opancerzone","methodology":"Kuloodporność","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kuloodporność","reference":"STANAG 4569 NIJ Standard – 0108.01 GOST R 50963-96 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 VPAM APR 2006 Edycja 12.05.2010 VPAM BRV 1999 VPAM BRV 2009","norm_bases":["STANAG 4569 NIJ Standard – 0108.01 GOST R 50963-96 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 VPAM APR 2006 Edycja 12.05.2010 VPAM BRV 1999 VPAM BRV 2009"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pojazdy opancerzone Kuloodporność STANAG 4569 NIJ Standard – 0108.01 GOST R 50963-96 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 VPAM APR 2006 Edycja 12.05.2010 VPAM BRV 1999 VPAM BRV 2009 Pojazdy opancerzone Kuloodpornosc STANAG 4569 NIJ Standard – 0108.01 GOST R 50963-96 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 VPAM APR 2006 Edycja 12.05.2010 VPAM BRV 1999 VPAM BRV 2009","categories":["automotive"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bullet resistance","search_en":"Armoured vehicles Bullet resistance STANAG 4569 NIJ Standard – 0108.01 GOST R 50963-96 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 VPAM APR 2006 Edycja 12.05.2010 VPAM BRV 1999 VPAM BRV 2009","test_object_en":"Armoured vehicles","methodology_zh":"防弹性","search_zh":"防弹性 STANAG 4569 NIJ Standard – 0108.01 GOST R 50963-96 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 VPAM APR 2006 Edycja 12.05.2010 VPAM BRV 1999 VPAM BRV 2009"},{"_id":"6a82ef00884ede9a1b2c4b5b","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Pojazdy opancerzone","methodology":"Odłamkoodporność","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odłamkoodporność","reference":"STANAG 4569 | STANAG 2920 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024","norm_bases":["STANAG 4569","STANAG 2920 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pojazdy opancerzone Odłamkoodporność STANAG 4569 | STANAG 2920 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024 Pojazdy opancerzone Odlamkoodpornosc STANAG 4569 | STANAG 2920 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024","categories":["automotive"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fragment resistance","search_en":"Armoured vehicles Fragment resistance STANAG 4569 | STANAG 2920 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024","test_object_en":"Armoured vehicles","methodology_zh":"抗破片性","search_zh":"抗破片性 STANAG 4569 | STANAG 2920 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024"},{"_id":"6a82ef00884ede9a1b2c4b5c","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Próbki balistyczne, Dopancerzenia statków powietrznych, okrętów i ich elementy","methodology":"Kuloodporność","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kuloodporność","reference":"STANAG 4569 | STANAG 4164 NO-13-A511:2005 NO-13-A511/A1:2016 | STANAG 4190 NO-13-A512:2005 NO-13-A512/A1:2015 NIJ Standard – 0108.01 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 VPAM APR 2006 Edycja 12.05.2010","norm_bases":["STANAG 4569","STANAG 4164 NO-13-A511:2005 NO-13-A511/A1:2016","STANAG 4190 NO-13-A512:2005 NO-13-A512/A1:2015 NIJ Standard – 0108.01 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 VPAM APR 2006 Edycja 12.05.2010"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki balistyczne, Dopancerzenia statków powietrznych, okrętów i ich elementy Kuloodporność STANAG 4569 | STANAG 4164 NO-13-A511:2005 NO-13-A511/A1:2016 | STANAG 4190 NO-13-A512:2005 NO-13-A512/A1:2015 NIJ Standard – 0108.01 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 VPAM APR 2006 Edycja 12.05.2010 Probki balistyczne, Dopancerzenia statkow powietrznych, okretow i ich elementy Kuloodpornosc STANAG 4569 | STANAG 4164 NO-13-A511:2005 NO-13-A511/A1:2016 | STANAG 4190 NO-13-A512:2005 NO-13-A512/A1:2015 NIJ Standard – 0108.01 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 VPAM APR 2006 Edycja 12.05.2010","categories":["other"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bullet resistance","search_en":"Ballistic samples, Add-on armour for aircraft, ships and their components Bullet resistance STANAG 4569 | STANAG 4164 NO-13-A511:2005 NO-13-A511/A1:2016 | STANAG 4190 NO-13-A512:2005 NO-13-A512/A1:2015 NIJ Standard – 0108.01 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 VPAM APR 2006 Edycja 12.05.2010","test_object_en":"Ballistic samples, Add-on armour for aircraft, ships and their components","methodology_zh":"防弹性","search_zh":"防弹性 STANAG 4569 | STANAG 4164 NO-13-A511:2005 NO-13-A511/A1:2016 | STANAG 4190 NO-13-A512:2005 NO-13-A512/A1:2015 NIJ Standard – 0108.01 Procedura LBUSO.PB.12 Edycja 7 z dnia 10.01.2024 VPAM APR 2006 Edycja 12.05.2010"},{"_id":"6a82ef00884ede9a1b2c4b5d","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Próbki balistyczne, Dopancerzenia statków powietrznych, okrętów i ich elementy","methodology":"Odłamkoodporność","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odłamkoodporność","reference":"STANAG 4569 | STANAG 2920 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024","norm_bases":["STANAG 4569","STANAG 2920 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki balistyczne, Dopancerzenia statków powietrznych, okrętów i ich elementy Odłamkoodporność STANAG 4569 | STANAG 2920 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024 Probki balistyczne, Dopancerzenia statkow powietrznych, okretow i ich elementy Odlamkoodpornosc STANAG 4569 | STANAG 2920 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024","categories":["other"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fragment resistance","search_en":"Ballistic samples, Add-on armour for aircraft, ships and their components Fragment resistance STANAG 4569 | STANAG 2920 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024","test_object_en":"Ballistic samples, Add-on armour for aircraft, ships and their components","methodology_zh":"抗破片性","search_zh":"抗破片性 STANAG 4569 | STANAG 2920 Procedura LBUSO.PB.16 Edycja 5 z dnia 10.01.2024"},{"_id":"6a82ef00884ede9a1b2c4b5e","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Broń strzelecka i lotnicza oraz granatniki kalibru do 40 mm","methodology":"Celność, Położenie średniego punktu trafienia (SPT od punktu kontrolnego PK)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Celność, Położenie średniego punktu trafienia (SPT od punktu kontrolnego PK)","reference":"NO-10-A500-2:2008 Procedura LBUSO.PB.08 Edycja 4 z dnia 04.04.2022","norm_bases":["NO-10-A500-2:2008 Procedura LBUSO.PB.08 Edycja 4 z dnia 04.04.2022"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Broń strzelecka i lotnicza oraz granatniki kalibru do 40 mm Celność, Położenie średniego punktu trafienia (SPT od punktu kontrolnego PK) NO-10-A500-2:2008 Procedura LBUSO.PB.08 Edycja 4 z dnia 04.04.2022 Bron strzelecka i lotnicza oraz granatniki kalibru do 40 mm Celnosc, Polozenie sredniego punktu trafienia (SPT od punktu kontrolnego PK) NO-10-A500-2:2008 Procedura LBUSO.PB.08 Edycja 4 z dnia 04.04.2022","categories":["other"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Accuracy of fire, Position of the mean point of impact (MPI from the check point CP)","search_en":"Small arms and aircraft armament and grenade launchers of calibre up to 40 mm Accuracy of fire, Position of the mean point of impact (MPI from the check point CP) NO-10-A500-2:2008 Procedura LBUSO.PB.08 Edycja 4 z dnia 04.04.2022","test_object_en":"Small arms and aircraft armament and grenade launchers of calibre up to 40 mm","search_zh":"枪械、航空武器及口径至 40 mm 的榴弹发射器 NO-10-A500-2:2008 Procedura LBUSO.PB.08 Edycja 4 z dnia 04.04.2022","test_object_zh":"枪械、航空武器及口径至 40 mm 的榴弹发射器"},{"_id":"6a82ef00884ede9a1b2c4b5f","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Broń strzelecka i lotnicza oraz granatniki kalibru do 40 mm","methodology":"Żywotność broni strzeleckiej, Niezawodność działania automatyki","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Żywotność broni strzeleckiej, Niezawodność działania automatyki","reference":"NO-06-A101:2021 NO-06-A102: 2021 NO-06-A103: 2021 NO-06-A104: 2021 NO-06-A105: 2021 NO-06-A106: 2021 NO-06-A107: 2021 NO-06-A108: 2021 Procedura LBUSO.PB.10 Edycja 4 z dnia 15.02.2021 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","norm_bases":["NO-06-A101:2021 NO-06-A102: 2021 NO-06-A103: 2021 NO-06-A104: 2021 NO-06-A105: 2021 NO-06-A106: 2021 NO-06-A107: 2021 NO-06-A108: 2021 Procedura LBUSO.PB.10 Edycja 4 z dnia 15.02.2021 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Broń strzelecka i lotnicza oraz granatniki kalibru do 40 mm Żywotność broni strzeleckiej, Niezawodność działania automatyki NO-06-A101:2021 NO-06-A102: 2021 NO-06-A103: 2021 NO-06-A104: 2021 NO-06-A105: 2021 NO-06-A106: 2021 NO-06-A107: 2021 NO-06-A108: 2021 Procedura LBUSO.PB.10 Edycja 4 z dnia 15.02.2021 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024 Bron strzelecka i lotnicza oraz granatniki kalibru do 40 mm Zywotnosc broni strzeleckiej, Niezawodnosc dzialania automatyki NO-06-A101:2021 NO-06-A102: 2021 NO-06-A103: 2021 NO-06-A104: 2021 NO-06-A105: 2021 NO-06-A106: 2021 NO-06-A107: 2021 NO-06-A108: 2021 Procedura LBUSO.PB.10 Edycja 4 z dnia 15.02.2021 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","categories":["other"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Service life of small arms, Reliability of the automatic mechanism","search_en":"Small arms and aircraft armament and grenade launchers of calibre up to 40 mm Service life of small arms, Reliability of the automatic mechanism NO-06-A101:2021 NO-06-A102: 2021 NO-06-A103: 2021 NO-06-A104: 2021 NO-06-A105: 2021 NO-06-A106: 2021 NO-06-A107: 2021 NO-06-A108: 2021 Procedura LBUSO.PB.10 Edycja 4 z dnia 15.02.2021 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","test_object_en":"Small arms and aircraft armament and grenade launchers of calibre up to 40 mm","search_zh":"枪械、航空武器及口径至 40 mm 的榴弹发射器 NO-06-A101:2021 NO-06-A102: 2021 NO-06-A103: 2021 NO-06-A104: 2021 NO-06-A105: 2021 NO-06-A106: 2021 NO-06-A107: 2021 NO-06-A108: 2021 Procedura LBUSO.PB.10 Edycja 4 z dnia 15.02.2021 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","test_object_zh":"枪械、航空武器及口径至 40 mm 的榴弹发射器"},{"_id":"6a82ef00884ede9a1b2c4b60","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Broń strzelecka i lotnicza oraz granatniki kalibru do 40 mm","methodology":"Badanie bezpieczeństwa broni strzeleckiej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie bezpieczeństwa broni strzeleckiej","reference":"NO-10-A500-4:2014 Procedura LBUSO.PB.09 Edycja 8 z dnia 10.01.2024 | STANAG 4375","norm_bases":["NO-10-A500-4:2014 Procedura LBUSO.PB.09 Edycja 8 z dnia 10.01.2024","STANAG 4375"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Broń strzelecka i lotnicza oraz granatniki kalibru do 40 mm Badanie bezpieczeństwa broni strzeleckiej NO-10-A500-4:2014 Procedura LBUSO.PB.09 Edycja 8 z dnia 10.01.2024 | STANAG 4375 Bron strzelecka i lotnicza oraz granatniki kalibru do 40 mm Badanie bezpieczenstwa broni strzeleckiej NO-10-A500-4:2014 Procedura LBUSO.PB.09 Edycja 8 z dnia 10.01.2024 | STANAG 4375","categories":["other"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing of small arms","search_en":"Small arms and aircraft armament and grenade launchers of calibre up to 40 mm Safety testing of small arms NO-10-A500-4:2014 Procedura LBUSO.PB.09 Edycja 8 z dnia 10.01.2024 | STANAG 4375","test_object_en":"Small arms and aircraft armament and grenade launchers of calibre up to 40 mm","search_zh":"枪械、航空武器及口径至 40 mm 的榴弹发射器 NO-10-A500-4:2014 Procedura LBUSO.PB.09 Edycja 8 z dnia 10.01.2024 | STANAG 4375","test_object_zh":"枪械、航空武器及口径至 40 mm 的榴弹发射器"},{"_id":"6a82ef00884ede9a1b2c4b61","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Broń strzelecka i lotnicza oraz granatniki kalibru do 40 mm","methodology":"Działanie broni w trakcie i po narażeniach środowiskowych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Działanie broni w trakcie i po narażeniach środowiskowych","reference":"NO-10-A500-2:2008 NO-10-A500-5:2000 NO-10-A500-5/A1:2009 NO-10-A500-6:2000 NO-10-A500-6:2000/A1:2009 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","norm_bases":["NO-10-A500-2:2008 NO-10-A500-5:2000 NO-10-A500-5/A1:2009 NO-10-A500-6:2000 NO-10-A500-6:2000/A1:2009 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Broń strzelecka i lotnicza oraz granatniki kalibru do 40 mm Działanie broni w trakcie i po narażeniach środowiskowych NO-10-A500-2:2008 NO-10-A500-5:2000 NO-10-A500-5/A1:2009 NO-10-A500-6:2000 NO-10-A500-6:2000/A1:2009 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024 Bron strzelecka i lotnicza oraz granatniki kalibru do 40 mm Dzialanie broni w trakcie i po narazeniach srodowiskowych NO-10-A500-2:2008 NO-10-A500-5:2000 NO-10-A500-5/A1:2009 NO-10-A500-6:2000 NO-10-A500-6:2000/A1:2009 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Functioning of the weapon during and after environmental exposures","search_en":"Small arms and aircraft armament and grenade launchers of calibre up to 40 mm Functioning of the weapon during and after environmental exposures NO-10-A500-2:2008 NO-10-A500-5:2000 NO-10-A500-5/A1:2009 NO-10-A500-6:2000 NO-10-A500-6:2000/A1:2009 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","test_object_en":"Small arms and aircraft armament and grenade launchers of calibre up to 40 mm","search_zh":"枪械、航空武器及口径至 40 mm 的榴弹发射器 NO-10-A500-2:2008 NO-10-A500-5:2000 NO-10-A500-5/A1:2009 NO-10-A500-6:2000 NO-10-A500-6:2000/A1:2009 Procedura LBUSO.PB.25 Edycja 7 z dnia 10.01.2024","test_object_zh":"枪械、航空武器及口径至 40 mm 的榴弹发射器"},{"_id":"6a82ef00884ede9a1b2c4b62","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Broń strzelecka i lotnicza oraz granatniki kalibru do 40 mm","methodology":"Parametry fizyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Parametry fizyczne","reference":"Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022","norm_bases":["Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Broń strzelecka i lotnicza oraz granatniki kalibru do 40 mm Parametry fizyczne Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022 Bron strzelecka i lotnicza oraz granatniki kalibru do 40 mm Parametry fizyczne Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022","categories":["other"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Physical parameters","search_en":"Small arms and aircraft armament and grenade launchers of calibre up to 40 mm Physical parameters Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022","test_object_en":"Small arms and aircraft armament and grenade launchers of calibre up to 40 mm","search_zh":"枪械、航空武器及口径至 40 mm 的榴弹发射器 物理参数 Procedura LBUSO.PB.27 Edycja 4 z dnia 10.10.2022","test_object_zh":"枪械、航空武器及口径至 40 mm 的榴弹发射器","methodology_zh":"物理参数"},{"_id":"6a82ef00884ede9a1b2c4b63","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Broń strzelecka i lotnicza oraz granatniki kalibru do 40 mm","methodology":"Zgodność z dokumentacją - jakość znakowania i ukompletowania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zgodność z dokumentacją - jakość znakowania i ukompletowania","reference":"Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024","norm_bases":["Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024"],"lab_section":"Laboratorium Badań Uzbrojenia Strzeleckiego i Osłon Zabezpieczających","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Broń strzelecka i lotnicza oraz granatniki kalibru do 40 mm Zgodność z dokumentacją - jakość znakowania i ukompletowania Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024 Bron strzelecka i lotnicza oraz granatniki kalibru do 40 mm Zgodnosc z dokumentacja - jakosc znakowania i ukompletowania Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024","categories":["other"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Conformity with documentation - quality of marking and completeness","search_en":"Small arms and aircraft armament and grenade launchers of calibre up to 40 mm Conformity with documentation - quality of marking and completeness Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024","test_object_en":"Small arms and aircraft armament and grenade launchers of calibre up to 40 mm","search_zh":"枪械、航空武器及口径至 40 mm 的榴弹发射器 与文件的符合性 － 标识与配套的质量 Procedura LBUSO.PB.32 Edycja 7 z dnia 10.01.2024","test_object_zh":"枪械、航空武器及口径至 40 mm 的榴弹发射器","methodology_zh":"与文件的符合性 － 标识与配套的质量"},{"_id":"6a82ef00884ede9a1b2c4b64","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Rakiety przeciwlotnicze bliskiego zasięgu","methodology":"Parametry elektryczne rakiety:","parameters":[{"name":"napięcie sygnałów"}],"technique":null,"techniques":[],"computed":[],"activity":"Parametry elektryczne rakiety:\nnapięcie sygnałów","reference":"Procedura LBAR.PB.26 Edycja 4 z dnia 07.09.2021","norm_bases":["Procedura LBAR.PB.26 Edycja 4 z dnia 07.09.2021"],"lab_section":"Laboratorium Badań Sprzętu i Amunicji Artyleryjskiej, Rakiet i Zespołów Rakiet","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rakiety przeciwlotnicze bliskiego zasięgu Parametry elektryczne rakiety:\nnapięcie sygnałów Procedura LBAR.PB.26 Edycja 4 z dnia 07.09.2021 Rakiety przeciwlotnicze bliskiego zasiegu Parametry elektryczne rakiety:\nnapiecie sygnalow Procedura LBAR.PB.26 Edycja 4 z dnia 07.09.2021","categories":["other"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical parameters of the rocket:","parameters_en":[{"name":"signal voltage"}],"search_en":"Short-range anti-aircraft missiles Electrical parameters of the rocket: signal voltage Procedura LBAR.PB.26 Edycja 4 z dnia 07.09.2021","test_object_en":"Short-range anti-aircraft missiles","search_zh":"近程防空导弹 Procedura LBAR.PB.26 Edycja 4 z dnia 07.09.2021","test_object_zh":"近程防空导弹"},{"_id":"6a82ef00884ede9a1b2c4b65","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Rakiety przeciwlotnicze bliskiego zasięgu","methodology":"Napromieniowanie tła i celu w podczerwieni, Zakres długości fal: (1,5 – 3) μm (3,9 – 5,1) μm","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Napromieniowanie tła i celu w podczerwieni, Zakres długości fal: (1,5 – 3) μm (3,9 – 5,1) μm","reference":"Procedura LBAR.PB.28 Edycja 4 z dnia 07.09.2021","norm_bases":["Procedura LBAR.PB.28 Edycja 4 z dnia 07.09.2021"],"lab_section":"Laboratorium Badań Sprzętu i Amunicji Artyleryjskiej, Rakiet i Zespołów Rakiet","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rakiety przeciwlotnicze bliskiego zasięgu Napromieniowanie tła i celu w podczerwieni, Zakres długości fal: (1,5 – 3) μm (3,9 – 5,1) μm Procedura LBAR.PB.28 Edycja 4 z dnia 07.09.2021 Rakiety przeciwlotnicze bliskiego zasiegu Napromieniowanie tla i celu w podczerwieni, Zakres dlugosci fal: (1,5 – 3) μm (3,9 – 5,1) μm Procedura LBAR.PB.28 Edycja 4 z dnia 07.09.2021","categories":["other"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Short-range anti-aircraft missiles Procedura LBAR.PB.28 Edycja 4 z dnia 07.09.2021","test_object_en":"Short-range anti-aircraft missiles","search_zh":"近程防空导弹 Procedura LBAR.PB.28 Edycja 4 z dnia 07.09.2021","test_object_zh":"近程防空导弹"},{"_id":"6a82ef00884ede9a1b2c4b66","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Rakiety przeciwlotnicze bliskiego zasięgu","methodology":"Parametry balistyczne odcinka startowego:","parameters":[{"name":"odległość zadziałania silnika marszowego"},{"name":"czas działania opóźniacza zapłonu"}],"technique":null,"techniques":[],"computed":[],"activity":"Parametry balistyczne odcinka startowego:\nZakres:\nodległość zadziałania silnika marszowego\nczas działania opóźniacza zapłonu","reference":"Procedura LBAR.PB.29 Edycja 3 z dnia 07.09.2021","norm_bases":["Procedura LBAR.PB.29 Edycja 3 z dnia 07.09.2021"],"lab_section":"Laboratorium Badań Sprzętu i Amunicji Artyleryjskiej, Rakiet i Zespołów Rakiet","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rakiety przeciwlotnicze bliskiego zasięgu Parametry balistyczne odcinka startowego:\nZakres:\nodległość zadziałania silnika marszowego\nczas działania opóźniacza zapłonu Procedura LBAR.PB.29 Edycja 3 z dnia 07.09.2021 Rakiety przeciwlotnicze bliskiego zasiegu Parametry balistyczne odcinka startowego:\nZakres:\nodleglosc zadzialania silnika marszowego\nczas dzialania opozniacza zaplonu Procedura LBAR.PB.29 Edycja 3 z dnia 07.09.2021","categories":["other"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ballistic parameters of the launch section:","parameters_en":[{"name":"operating distance of the sustainer motor"},{"name":"operating time of the ignition delay device"}],"search_en":"Short-range anti-aircraft missiles Ballistic parameters of the launch section: operating distance of the sustainer motor operating time of the ignition delay device Procedura LBAR.PB.29 Edycja 3 z dnia 07.09.2021","test_object_en":"Short-range anti-aircraft missiles","search_zh":"近程防空导弹 Procedura LBAR.PB.29 Edycja 3 z dnia 07.09.2021","test_object_zh":"近程防空导弹"},{"_id":"6a82ef00884ede9a1b2c4b67","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Rakiety przeciwlotnicze bliskiego zasięgu","methodology":"Parametry balistyczne trajektorii lotu rakiety:","parameters":[{"name":"współrzędne toru lotu (x,y,z)"},{"name":"odległość"},{"name":"prędkość na torze lotu"},{"name":"uchyb w rejonie celu"}],"technique":null,"techniques":[],"computed":[],"activity":"Parametry balistyczne trajektorii lotu rakiety:\nZakres:\nwspółrzędne toru lotu (x,y,z)\nodległość\nprędkość na torze lotu\nuchyb w rejonie celu","reference":"Procedura LBAR.PB.30 Edycja 5 z dnia 07.09.2021","norm_bases":["Procedura LBAR.PB.30 Edycja 5 z dnia 07.09.2021"],"lab_section":"Laboratorium Badań Sprzętu i Amunicji Artyleryjskiej, Rakiet i Zespołów Rakiet","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rakiety przeciwlotnicze bliskiego zasięgu Parametry balistyczne trajektorii lotu rakiety:\nZakres:\nwspółrzędne toru lotu (x,y,z)\nodległość\nprędkość na torze lotu\nuchyb w rejonie celu Procedura LBAR.PB.30 Edycja 5 z dnia 07.09.2021 Rakiety przeciwlotnicze bliskiego zasiegu Parametry balistyczne trajektorii lotu rakiety:\nZakres:\nwspolrzedne toru lotu (x,y,z)\nodleglosc\npredkosc na torze lotu\nuchyb w rejonie celu Procedura LBAR.PB.30 Edycja 5 z dnia 07.09.2021","categories":["other"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ballistic parameters of the rocket flight trajectory:","parameters_en":[{"name":"flight path coordinates (x,y,z)"},{"name":"distance"},{"name":"velocity on the flight path"},{"name":"deviation in the target area"}],"search_en":"Short-range anti-aircraft missiles Ballistic parameters of the rocket flight trajectory: flight path coordinates (x,y,z) distance velocity on the flight path deviation in the target area Procedura LBAR.PB.30 Edycja 5 z dnia 07.09.2021","test_object_en":"Short-range anti-aircraft missiles","search_zh":"近程防空导弹 Procedura LBAR.PB.30 Edycja 5 z dnia 07.09.2021","test_object_zh":"近程防空导弹"},{"_id":"6a82ef00884ede9a1b2c4b68","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Rakiety przeciwlotnicze bliskiego zasięgu","methodology":"Czas samolikwidacji rakiety","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Czas samolikwidacji rakiety","reference":"Procedura LBAR.PB.31 Edycja 4 z dnia 07.09.2021","norm_bases":["Procedura LBAR.PB.31 Edycja 4 z dnia 07.09.2021"],"lab_section":"Laboratorium Badań Sprzętu i Amunicji Artyleryjskiej, Rakiet i Zespołów Rakiet","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Rakiety przeciwlotnicze bliskiego zasięgu Czas samolikwidacji rakiety Procedura LBAR.PB.31 Edycja 4 z dnia 07.09.2021 Rakiety przeciwlotnicze bliskiego zasiegu Czas samolikwidacji rakiety Procedura LBAR.PB.31 Edycja 4 z dnia 07.09.2021","categories":["other"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Self-destruction time of the rocket","search_en":"Short-range anti-aircraft missiles Self-destruction time of the rocket Procedura LBAR.PB.31 Edycja 4 z dnia 07.09.2021","test_object_en":"Short-range anti-aircraft missiles","search_zh":"近程防空导弹 Procedura LBAR.PB.31 Edycja 4 z dnia 07.09.2021","test_object_zh":"近程防空导弹"},{"_id":"6a82ef00884ede9a1b2c4b69","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe miotające, pirotechniczne i wyroby zawierające materiały wybuchowe","methodology":"Wilgotność prochu czarnego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wilgotność prochu czarnego","reference":"PN-C-86002:1961 p.2.1 | PN-EN 13938-7:2007 Procedura LBŚB.PB.1 Edycja 4 z dnia 09.01.2023","norm_bases":["PN-C-86002:1961 p.2.1","PN-EN 13938-7:2007 Procedura LBŚB.PB.1 Edycja 4 z dnia 09.01.2023"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe miotające, pirotechniczne i wyroby zawierające materiały wybuchowe Wilgotność prochu czarnego PN-C-86002:1961 p.2.1 | PN-EN 13938-7:2007 Procedura LBŚB.PB.1 Edycja 4 z dnia 09.01.2023 Materialy wybuchowe miotajace, pirotechniczne i wyroby zawierajace materialy wybuchowe Wilgotnosc prochu czarnego PN-C-86002:1961 p.2.1 | PN-EN 13938-7:2007 Procedura LBSB.PB.1 Edycja 4 z dnia 09.01.2023","categories":["materials"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content of black powder","search_en":"Propellant and pyrotechnic explosives and articles containing explosives Moisture content of black powder PN-C-86002:1961 p.2.1 | PN-EN 13938-7:2007 Procedura LBŚB.PB.1 Edycja 4 z dnia 09.01.2023","test_object_en":"Propellant and pyrotechnic explosives and articles containing explosives","search_zh":"发射药、烟火药与含爆炸物的制品 PN-C-86002:1961 p.2.1 | PN-EN 13938-7:2007 Procedura LBŚB.PB.1 Edycja 4 z dnia 09.01.2023","test_object_zh":"发射药、烟火药与含爆炸物的制品"},{"_id":"6a82ef00884ede9a1b2c4b6a","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe miotające, pirotechniczne i wyroby zawierające materiały wybuchowe","methodology":"Zawartość części lotnych w prochach","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość części lotnych w prochach","reference":"PN-V-04012-8:1997 Procedura LBŚB.PB.2 Edycja 5 z dnia 19.05.2025","norm_bases":["PN-V-04012-8:1997 Procedura LBŚB.PB.2 Edycja 5 z dnia 19.05.2025"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe miotające, pirotechniczne i wyroby zawierające materiały wybuchowe Zawartość części lotnych w prochach PN-V-04012-8:1997 Procedura LBŚB.PB.2 Edycja 5 z dnia 19.05.2025 Materialy wybuchowe miotajace, pirotechniczne i wyroby zawierajace materialy wybuchowe Zawartosc czesci lotnych w prochach PN-V-04012-8:1997 Procedura LBSB.PB.2 Edycja 5 z dnia 19.05.2025","categories":["materials"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile matter content in powders","search_en":"Propellant and pyrotechnic explosives and articles containing explosives Volatile matter content in powders PN-V-04012-8:1997 Procedura LBŚB.PB.2 Edycja 5 z dnia 19.05.2025","test_object_en":"Propellant and pyrotechnic explosives and articles containing explosives","search_zh":"发射药、烟火药与含爆炸物的制品 PN-V-04012-8:1997 Procedura LBŚB.PB.2 Edycja 5 z dnia 19.05.2025","test_object_zh":"发射药、烟火药与含爆炸物的制品"},{"_id":"6a82ef00884ede9a1b2c4b6b","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe miotające, pirotechniczne i wyroby zawierające materiały wybuchowe","methodology":"Wilgotność prochu nitroglicerynowego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wilgotność prochu nitroglicerynowego","reference":"PN-C-86002:1961 p.2.1 Procedura LBŚB.PB.3 Edycja 3 z dnia 04.03.2020","norm_bases":["PN-C-86002:1961 p.2.1 Procedura LBŚB.PB.3 Edycja 3 z dnia 04.03.2020"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe miotające, pirotechniczne i wyroby zawierające materiały wybuchowe Wilgotność prochu nitroglicerynowego PN-C-86002:1961 p.2.1 Procedura LBŚB.PB.3 Edycja 3 z dnia 04.03.2020 Materialy wybuchowe miotajace, pirotechniczne i wyroby zawierajace materialy wybuchowe Wilgotnosc prochu nitroglicerynowego PN-C-86002:1961 p.2.1 Procedura LBSB.PB.3 Edycja 3 z dnia 04.03.2020","categories":["materials"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content of nitroglycerine powder","search_en":"Propellant and pyrotechnic explosives and articles containing explosives Moisture content of nitroglycerine powder PN-C-86002:1961 p.2.1 Procedura LBŚB.PB.3 Edycja 3 z dnia 04.03.2020","test_object_en":"Propellant and pyrotechnic explosives and articles containing explosives","search_zh":"发射药、烟火药与含爆炸物的制品 PN-C-86002:1961 p.2.1 Procedura LBŚB.PB.3 Edycja 3 z dnia 04.03.2020","test_object_zh":"发射药、烟火药与含爆炸物的制品"},{"_id":"6a82ef00884ede9a1b2c4b6c","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe miotające, pirotechniczne i wyroby zawierające materiały wybuchowe","methodology":"Ciepło spalania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ciepło spalania","reference":"Procedura LBŚB.PB.4 Edycja 4 z dnia 22.06.2020","norm_bases":["Procedura LBŚB.PB.4 Edycja 4 z dnia 22.06.2020"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe miotające, pirotechniczne i wyroby zawierające materiały wybuchowe Ciepło spalania Procedura LBŚB.PB.4 Edycja 4 z dnia 22.06.2020 Materialy wybuchowe miotajace, pirotechniczne i wyroby zawierajace materialy wybuchowe Cieplo spalania Procedura LBSB.PB.4 Edycja 4 z dnia 22.06.2020","categories":["materials"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","search_en":"Propellant and pyrotechnic explosives and articles containing explosives Gross calorific value Procedura LBŚB.PB.4 Edycja 4 z dnia 22.06.2020","test_object_en":"Propellant and pyrotechnic explosives and articles containing explosives","methodology_zh":"高位发热量","search_zh":"发射药、烟火药与含爆炸物的制品 高位发热量 Procedura LBŚB.PB.4 Edycja 4 z dnia 22.06.2020","test_object_zh":"发射药、烟火药与含爆炸物的制品"},{"_id":"6a82ef00884ede9a1b2c4b6d","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe miotające, pirotechniczne i wyroby zawierające materiały wybuchowe","methodology":"Trwałość chemiczna wg Bergmana-Junka","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Trwałość chemiczna wg Bergmana-Junka","reference":"NO-13-A505:2001 NO-13-A505/A1:2012 Procedura LBŚB.PB.5 Edycja 3 z dnia 04.03.2020","norm_bases":["NO-13-A505:2001 NO-13-A505/A1:2012 Procedura LBŚB.PB.5 Edycja 3 z dnia 04.03.2020"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe miotające, pirotechniczne i wyroby zawierające materiały wybuchowe Trwałość chemiczna wg Bergmana-Junka NO-13-A505:2001 NO-13-A505/A1:2012 Procedura LBŚB.PB.5 Edycja 3 z dnia 04.03.2020 Materialy wybuchowe miotajace, pirotechniczne i wyroby zawierajace materialy wybuchowe Trwalosc chemiczna wg Bergmana-Junka NO-13-A505:2001 NO-13-A505/A1:2012 Procedura LBSB.PB.5 Edycja 3 z dnia 04.03.2020","categories":["materials"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical stability according to Bergmann-Junk","search_en":"Propellant and pyrotechnic explosives and articles containing explosives Chemical stability according to Bergmann-Junk NO-13-A505:2001 NO-13-A505/A1:2012 Procedura LBŚB.PB.5 Edycja 3 z dnia 04.03.2020","test_object_en":"Propellant and pyrotechnic explosives and articles containing explosives","search_zh":"发射药、烟火药与含爆炸物的制品 NO-13-A505:2001 NO-13-A505/A1:2012 Procedura LBŚB.PB.5 Edycja 3 z dnia 04.03.2020","test_object_zh":"发射药、烟火药与含爆炸物的制品"},{"_id":"6a82ef00884ede9a1b2c4b6e","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe miotające, pirotechniczne i wyroby zawierające materiały wybuchowe","methodology":"Kształt i wymiary nabojów i ich elementów","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kształt i wymiary nabojów i ich elementów","reference":"Procedura LBŚB.PB.7 Edycja 3 z dnia 07.07.2020","norm_bases":["Procedura LBŚB.PB.7 Edycja 3 z dnia 07.07.2020"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe miotające, pirotechniczne i wyroby zawierające materiały wybuchowe Kształt i wymiary nabojów i ich elementów Procedura LBŚB.PB.7 Edycja 3 z dnia 07.07.2020 Materialy wybuchowe miotajace, pirotechniczne i wyroby zawierajace materialy wybuchowe Ksztalt i wymiary nabojow i ich elementow Procedura LBSB.PB.7 Edycja 3 z dnia 07.07.2020","categories":["materials"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Shape and dimensions of cartridges and their components","search_en":"Propellant and pyrotechnic explosives and articles containing explosives Shape and dimensions of cartridges and their components Procedura LBŚB.PB.7 Edycja 3 z dnia 07.07.2020","test_object_en":"Propellant and pyrotechnic explosives and articles containing explosives","search_zh":"发射药、烟火药与含爆炸物的制品 Procedura LBŚB.PB.7 Edycja 3 z dnia 07.07.2020","test_object_zh":"发射药、烟火药与含爆炸物的制品"},{"_id":"6a82ef00884ede9a1b2c4b6f","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe miotające, pirotechniczne i wyroby zawierające materiały wybuchowe","methodology":"Stabilność chemiczna (ubytek stabilizatora homogenicznych materiałów miotających na bazie nitrocelulozy)","parameters":[{"name":"dla stabilizatorów CI, CII i AkII –"},{"name":"Zakres","range":"0,008 - 3,6 %"},{"name":"dla stabilizatora DPA – 0,003 - 2,4 %"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Stabilność chemiczna (ubytek stabilizatora homogenicznych materiałów miotających na bazie nitrocelulozy)\nZakres:\ndla stabilizatorów CI, CII i AkII –\nZakres 0,008 - 3,6 %\ndla stabilizatora DPA – 0,003 - 2,4 %\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"AOP 48 Ed. 2 z 11.2008 Procedura LBŚB.PB.71 Edycja 2 z dnia 17.05.2024","norm_bases":["AOP 48 Ed. 2 z 11.2008 Procedura LBŚB.PB.71 Edycja 2 z dnia 17.05.2024"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe miotające, pirotechniczne i wyroby zawierające materiały wybuchowe Stabilność chemiczna (ubytek stabilizatora homogenicznych materiałów miotających na bazie nitrocelulozy)\nZakres:\ndla stabilizatorów CI, CII i AkII –\nZakres 0,008 - 3,6 %\ndla stabilizatora DPA – 0,003 - 2,4 %\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) AOP 48 Ed. 2 z 11.2008 Procedura LBŚB.PB.71 Edycja 2 z dnia 17.05.2024 Materialy wybuchowe miotajace, pirotechniczne i wyroby zawierajace materialy wybuchowe Stabilnosc chemiczna (ubytek stabilizatora homogenicznych materialow miotajacych na bazie nitrocelulozy)\nZakres:\ndla stabilizatorow CI, CII i AkII –\nZakres 0,008 - 3,6 %\ndla stabilizatora DPA – 0,003 - 2,4 %\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) AOP 48 Ed. 2 z 11.2008 Procedura LBSB.PB.71 Edycja 2 z dnia 17.05.2024","categories":["materials"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical stability (loss of stabiliser in homogeneous nitrocellulose-based propellants)","parameters_en":[{"name":"for CI, CII and AkII stabilisers –"},{"name":"Range","range":"0,008 - 3,6 %"},{"name":"for DPA stabiliser – 0,003 - 2,4 %"}],"search_en":"Propellant and pyrotechnic explosives and articles containing explosives Chemical stability (loss of stabiliser in homogeneous nitrocellulose-based propellants) High-performance liquid chromatography with diode array detection (HPLC-DAD) for CI, CII and AkII stabilisers – Range for DPA stabiliser – 0,003 - 2,4 % AOP 48 Ed. 2 z 11.2008 Procedura LBŚB.PB.71 Edycja 2 z dnia 17.05.2024","technique_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD)","test_object_en":"Propellant and pyrotechnic explosives and articles containing explosives","parameters_zh":[{"name":"dla stabilizatorów CI, CII i AkII –"},{"name":"范围","range":"0,008 - 3,6 %"},{"name":"dla stabilizatora DPA – 0,003 - 2,4 %"}],"search_zh":"发射药、烟火药与含爆炸物的制品 高效液相色谱-二极管阵列检测法（HPLC-DAD） 范围 AOP 48 Ed. 2 z 11.2008 Procedura LBŚB.PB.71 Edycja 2 z dnia 17.05.2024","technique_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD）","test_object_zh":"发射药、烟火药与含爆炸物的制品"},{"_id":"6a82ef00884ede9a1b2c4b70","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe kruszące i inicjujące","methodology":"Kwasowość","parameters":[{"name":"Zakres","range":"(0,001 – 0,05) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Kwasowość\nZakres (0,001 – 0,05) %\nMetoda miareczkowa","reference":"Procedura LBŚB.PB.13 Edycja 4 z dnia 18.01.2024","norm_bases":["Procedura LBŚB.PB.13 Edycja 4 z dnia 18.01.2024"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe kruszące i inicjujące Kwasowość\nZakres (0,001 – 0,05) %\nMetoda miareczkowa Procedura LBŚB.PB.13 Edycja 4 z dnia 18.01.2024 Materialy wybuchowe kruszace i inicjujace Kwasowosc\nZakres (0,001 – 0,05) %\nMetoda miareczkowa Procedura LBSB.PB.13 Edycja 4 z dnia 18.01.2024","categories":["materials"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acidity","parameters_en":[{"name":"Range","range":"(0,001 – 0,05) %"}],"search_en":"High explosives and initiating explosives Acidity Titrimetric method Range Procedura LBŚB.PB.13 Edycja 4 z dnia 18.01.2024","technique_en":"Titrimetric method","test_object_en":"High explosives and initiating explosives","methodology_zh":"酸度","parameters_zh":[{"name":"范围","range":"(0,001 – 0,05) %"}],"search_zh":"酸度 滴定法 范围 Procedura LBŚB.PB.13 Edycja 4 z dnia 18.01.2024","technique_zh":"滴定法"},{"_id":"6a82ef00884ede9a1b2c4b71","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe kruszące i inicjujące","methodology":"Zawartość składników nierozpuszczalnych w acetonie","parameters":[{"name":"Zakres","range":"(0,004 – 0,40) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość składników nierozpuszczalnych w acetonie\nZakres (0,004 – 0,40) %\nMetoda wagowa","reference":"Procedura LBŚB.PB.14 Edycja 4 z dnia 09.03.2020","norm_bases":["Procedura LBŚB.PB.14 Edycja 4 z dnia 09.03.2020"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe kruszące i inicjujące Zawartość składników nierozpuszczalnych w acetonie\nZakres (0,004 – 0,40) %\nMetoda wagowa Procedura LBŚB.PB.14 Edycja 4 z dnia 09.03.2020 Materialy wybuchowe kruszace i inicjujace Zawartosc skladnikow nierozpuszczalnych w acetonie\nZakres (0,004 – 0,40) %\nMetoda wagowa Procedura LBSB.PB.14 Edycja 4 z dnia 09.03.2020","categories":["materials"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of acetone-insoluble components","parameters_en":[{"name":"Range","range":"(0,004 – 0,40) %"}],"search_en":"High explosives and initiating explosives Content of acetone-insoluble components Gravimetric method Range Procedura LBŚB.PB.14 Edycja 4 z dnia 09.03.2020","technique_en":"Gravimetric method","test_object_en":"High explosives and initiating explosives","parameters_zh":[{"name":"范围","range":"(0,004 – 0,40) %"}],"search_zh":"重量法 范围 Procedura LBŚB.PB.14 Edycja 4 z dnia 09.03.2020","technique_zh":"重量法"},{"_id":"6a82ef00884ede9a1b2c4b72","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe, substancje o własnościach wybuchowych, Lonty","methodology":"Stałość termiczna - metoda wagowa","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stałość termiczna - metoda wagowa","reference":"PN-EN 13938-1:2006 Procedura LBŚB.PB.16 Edycja 4 z dnia 09.03.2020","norm_bases":["PN-EN 13938-1:2006 Procedura LBŚB.PB.16 Edycja 4 z dnia 09.03.2020"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe, substancje o własnościach wybuchowych, Lonty Stałość termiczna - metoda wagowa PN-EN 13938-1:2006 Procedura LBŚB.PB.16 Edycja 4 z dnia 09.03.2020 Materialy wybuchowe, substancje o wlasnosciach wybuchowych, Lonty Stalosc termiczna - metoda wagowa PN-EN 13938-1:2006 Procedura LBSB.PB.16 Edycja 4 z dnia 09.03.2020","categories":["materials"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Thermal stability - gravimetric method","search_en":"Explosives, substances with explosive properties, Fuses Thermal stability - gravimetric method PN-EN 13938-1:2006 Procedura LBŚB.PB.16 Edycja 4 z dnia 09.03.2020","test_object_en":"Explosives, substances with explosive properties, Fuses","search_zh":"爆炸物、具有爆炸性质的物质、导火索 PN-EN 13938-1:2006 Procedura LBŚB.PB.16 Edycja 4 z dnia 09.03.2020","test_object_zh":"爆炸物、具有爆炸性质的物质、导火索"},{"_id":"6a82ef00884ede9a1b2c4b73","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe, substancje o własnościach wybuchowych, Lonty","methodology":"Wrażliwość na tarcie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wrażliwość na tarcie","reference":"PN-EN 13631-3:2006 | PN-EN 13630-3:2004 | STANAG 4487 ed. 2, 2009 Procedura LBŚB.PB.18 Edycja 5 z dnia 08.03.2021","norm_bases":["PN-EN 13631-3:2006","PN-EN 13630-3:2004","STANAG 4487 ed. 2, 2009 Procedura LBŚB.PB.18 Edycja 5 z dnia 08.03.2021"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe, substancje o własnościach wybuchowych, Lonty Wrażliwość na tarcie PN-EN 13631-3:2006 | PN-EN 13630-3:2004 | STANAG 4487 ed. 2, 2009 Procedura LBŚB.PB.18 Edycja 5 z dnia 08.03.2021 Materialy wybuchowe, substancje o wlasnosciach wybuchowych, Lonty Wrazliwosc na tarcie PN-EN 13631-3:2006 | PN-EN 13630-3:2004 | STANAG 4487 ed. 2, 2009 Procedura LBSB.PB.18 Edycja 5 z dnia 08.03.2021","categories":["materials"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Friction sensitivity","search_en":"Explosives, substances with explosive properties, Fuses Friction sensitivity PN-EN 13631-3:2006 | PN-EN 13630-3:2004 | STANAG 4487 ed. 2, 2009 Procedura LBŚB.PB.18 Edycja 5 z dnia 08.03.2021","test_object_en":"Explosives, substances with explosive properties, Fuses","search_zh":"爆炸物、具有爆炸性质的物质、导火索 PN-EN 13631-3:2006 | PN-EN 13630-3:2004 | STANAG 4487 ed. 2, 2009 Procedura LBŚB.PB.18 Edycja 5 z dnia 08.03.2021","test_object_zh":"爆炸物、具有爆炸性质的物质、导火索"},{"_id":"6a82ef00884ede9a1b2c4b74","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe, substancje o własnościach wybuchowych, Lonty","methodology":"Zawartość wody i części lotnych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wody i części lotnych","reference":"PN-EN 13631-1:2006 Procedura LBŚB.PB.19 Edycja 4 z dnia 09.03.2020","norm_bases":["PN-EN 13631-1:2006 Procedura LBŚB.PB.19 Edycja 4 z dnia 09.03.2020"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe, substancje o własnościach wybuchowych, Lonty Zawartość wody i części lotnych PN-EN 13631-1:2006 Procedura LBŚB.PB.19 Edycja 4 z dnia 09.03.2020 Materialy wybuchowe, substancje o wlasnosciach wybuchowych, Lonty Zawartosc wody i czesci lotnych PN-EN 13631-1:2006 Procedura LBSB.PB.19 Edycja 4 z dnia 09.03.2020","categories":["materials","water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of water and volatile matter","search_en":"Explosives, substances with explosive properties, Fuses Content of water and volatile matter PN-EN 13631-1:2006 Procedura LBŚB.PB.19 Edycja 4 z dnia 09.03.2020","test_object_en":"Explosives, substances with explosive properties, Fuses","search_zh":"爆炸物、具有爆炸性质的物质、导火索 PN-EN 13631-1:2006 Procedura LBŚB.PB.19 Edycja 4 z dnia 09.03.2020","test_object_zh":"爆炸物、具有爆炸性质的物质、导火索"},{"_id":"6a82ef00884ede9a1b2c4b75","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe, substancje o własnościach wybuchowych, Lonty","methodology":"Gęstość – metodą piknometryczną","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość – metodą piknometryczną","reference":"PN-V-04011-12:1997 p.2.4 i 2.5 | PN-EN 13631-13:2005 AOP-4682:2018 Procedura LBŚB.PB.20 Edycja 4 z dnia 09.03.2020","norm_bases":["PN-V-04011-12:1997 p.2.4 i 2.5","PN-EN 13631-13:2005 AOP-4682:2018 Procedura LBŚB.PB.20 Edycja 4 z dnia 09.03.2020"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe, substancje o własnościach wybuchowych, Lonty Gęstość – metodą piknometryczną PN-V-04011-12:1997 p.2.4 i 2.5 | PN-EN 13631-13:2005 AOP-4682:2018 Procedura LBŚB.PB.20 Edycja 4 z dnia 09.03.2020 Materialy wybuchowe, substancje o wlasnosciach wybuchowych, Lonty Gestosc – metoda piknometryczna PN-V-04011-12:1997 p.2.4 i 2.5 | PN-EN 13631-13:2005 AOP-4682:2018 Procedura LBSB.PB.20 Edycja 4 z dnia 09.03.2020","categories":["materials"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density – pycnometric method","search_en":"Explosives, substances with explosive properties, Fuses Density – pycnometric method PN-V-04011-12:1997 p.2.4 i 2.5 | PN-EN 13631-13:2005 AOP-4682:2018 Procedura LBŚB.PB.20 Edycja 4 z dnia 09.03.2020","test_object_en":"Explosives, substances with explosive properties, Fuses","search_zh":"爆炸物、具有爆炸性质的物质、导火索 PN-V-04011-12:1997 p.2.4 i 2.5 | PN-EN 13631-13:2005 AOP-4682:2018 Procedura LBŚB.PB.20 Edycja 4 z dnia 09.03.2020","test_object_zh":"爆炸物、具有爆炸性质的物质、导火索"},{"_id":"6a82ef00884ede9a1b2c4b76","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe, substancje o własnościach wybuchowych, Lonty","methodology":"Wrażliwość na uderzenie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wrażliwość na uderzenie","reference":"PN-EN 13631-4:2004 | PN-EN 13938-1:2006 | STANAG 4489 ed. 1, 1999 Procedura LBŚB.PB.36 Edycja 5 z dnia 06.12.2021","norm_bases":["PN-EN 13631-4:2004","PN-EN 13938-1:2006","STANAG 4489 ed. 1, 1999 Procedura LBŚB.PB.36 Edycja 5 z dnia 06.12.2021"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe, substancje o własnościach wybuchowych, Lonty Wrażliwość na uderzenie PN-EN 13631-4:2004 | PN-EN 13938-1:2006 | STANAG 4489 ed. 1, 1999 Procedura LBŚB.PB.36 Edycja 5 z dnia 06.12.2021 Materialy wybuchowe, substancje o wlasnosciach wybuchowych, Lonty Wrazliwosc na uderzenie PN-EN 13631-4:2004 | PN-EN 13938-1:2006 | STANAG 4489 ed. 1, 1999 Procedura LBSB.PB.36 Edycja 5 z dnia 06.12.2021","categories":["materials"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impact sensitivity","search_en":"Explosives, substances with explosive properties, Fuses Impact sensitivity PN-EN 13631-4:2004 | PN-EN 13938-1:2006 | STANAG 4489 ed. 1, 1999 Procedura LBŚB.PB.36 Edycja 5 z dnia 06.12.2021","test_object_en":"Explosives, substances with explosive properties, Fuses","search_zh":"爆炸物、具有爆炸性质的物质、导火索 PN-EN 13631-4:2004 | PN-EN 13938-1:2006 | STANAG 4489 ed. 1, 1999 Procedura LBŚB.PB.36 Edycja 5 z dnia 06.12.2021","test_object_zh":"爆炸物、具有爆炸性质的物质、导火索"},{"_id":"6a82ef00884ede9a1b2c4b77","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe, substancje o własnościach wybuchowych, Lonty","methodology":"Parametry fali podmuchowej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Parametry fali podmuchowej","reference":"Procedura LBŚB.PB.79 Edycja 1 z dnia 04.02.2025","norm_bases":["Procedura LBŚB.PB.79 Edycja 1 z dnia 04.02.2025"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe, substancje o własnościach wybuchowych, Lonty Parametry fali podmuchowej Procedura LBŚB.PB.79 Edycja 1 z dnia 04.02.2025 Materialy wybuchowe, substancje o wlasnosciach wybuchowych, Lonty Parametry fali podmuchowej Procedura LBSB.PB.79 Edycja 1 z dnia 04.02.2025","categories":["materials"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Blast wave parameters","search_en":"Explosives, substances with explosive properties, Fuses Blast wave parameters Procedura LBŚB.PB.79 Edycja 1 z dnia 04.02.2025","test_object_en":"Explosives, substances with explosive properties, Fuses","search_zh":"爆炸物、具有爆炸性质的物质、导火索 Procedura LBŚB.PB.79 Edycja 1 z dnia 04.02.2025","test_object_zh":"爆炸物、具有爆炸性质的物质、导火索"},{"_id":"6a82ef00884ede9a1b2c4b78","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Wyroby zawierające materiały wybuchowe i opakowania zbiorcze z wyrobami","methodology":"Hermetyczność wyrobów","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Hermetyczność wyrobów","reference":"PN-V-04002-3:1996 | PN-V-04002-4:1996 | PN-EN 13631-5:2004 | PN-EN 13631-6:2004 Procedura LBŚB.PB.37 Edycja 4 z dnia 09.03.2020","norm_bases":["PN-V-04002-3:1996","PN-V-04002-4:1996","PN-EN 13631-5:2004","PN-EN 13631-6:2004 Procedura LBŚB.PB.37 Edycja 4 z dnia 09.03.2020"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby zawierające materiały wybuchowe i opakowania zbiorcze z wyrobami Hermetyczność wyrobów PN-V-04002-3:1996 | PN-V-04002-4:1996 | PN-EN 13631-5:2004 | PN-EN 13631-6:2004 Procedura LBŚB.PB.37 Edycja 4 z dnia 09.03.2020 Wyroby zawierajace materialy wybuchowe i opakowania zbiorcze z wyrobami Hermetycznosc wyrobow PN-V-04002-3:1996 | PN-V-04002-4:1996 | PN-EN 13631-5:2004 | PN-EN 13631-6:2004 Procedura LBSB.PB.37 Edycja 4 z dnia 09.03.2020","categories":["materials"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Tightness of products","search_en":"Articles containing explosives and outer packagings with articles Tightness of products PN-V-04002-3:1996 | PN-V-04002-4:1996 | PN-EN 13631-5:2004 | PN-EN 13631-6:2004 Procedura LBŚB.PB.37 Edycja 4 z dnia 09.03.2020","test_object_en":"Articles containing explosives and outer packagings with articles"},{"_id":"6a82ef00884ede9a1b2c4b79","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Lonty detonujące, lonty prochowe","methodology":"Właściwości fizyczne:","parameters":[{"name":"barwa i wygląd"},{"name":"średnica i długość"},{"name":"masa"},{"name":"wodoodporność Właściwości użytkowe:"},{"name":"czas palenia"},{"name":"odporność na obniżoną i podwyższoną temperaturę"},{"name":"zdolność do inicjowania, zapalania, przenoszenia detonacji"},{"name":"stabilność termiczna"}],"technique":null,"techniques":[],"computed":[],"activity":"Właściwości fizyczne:\nZakres:\nbarwa i wygląd\nśrednica i długość\nmasa\nwodoodporność Właściwości użytkowe:\nczas palenia\nodporność na obniżoną i podwyższoną temperaturę\nzdolność do inicjowania, zapalania, przenoszenia detonacji\nstabilność termiczna","reference":"NO-13-A222:2021 NO-13-A249:2020 | PN-EN 13630-1:2005 | PN-EN 13630-2:2004 | PN-EN 13630-7:2004 | PN-EN 13630-8:2004 | PN-EN 13630-9:2006 | PN-EN 13630-12:2004","norm_bases":["NO-13-A222:2021 NO-13-A249:2020","PN-EN 13630-1:2005","PN-EN 13630-2:2004","PN-EN 13630-7:2004","PN-EN 13630-8:2004","PN-EN 13630-9:2006","PN-EN 13630-12:2004"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Lonty detonujące, lonty prochowe Właściwości fizyczne:\nZakres:\nbarwa i wygląd\nśrednica i długość\nmasa\nwodoodporność Właściwości użytkowe:\nczas palenia\nodporność na obniżoną i podwyższoną temperaturę\nzdolność do inicjowania, zapalania, przenoszenia detonacji\nstabilność termiczna NO-13-A222:2021 NO-13-A249:2020 | PN-EN 13630-1:2005 | PN-EN 13630-2:2004 | PN-EN 13630-7:2004 | PN-EN 13630-8:2004 | PN-EN 13630-9:2006 | PN-EN 13630-12:2004 Lonty detonujace, lonty prochowe Wlasciwosci fizyczne:\nZakres:\nbarwa i wyglad\nsrednica i dlugosc\nmasa\nwodoodpornosc Wlasciwosci uzytkowe:\nczas palenia\nodpornosc na obnizona i podwyzszona temperature\nzdolnosc do inicjowania, zapalania, przenoszenia detonacji\nstabilnosc termiczna NO-13-A222:2021 NO-13-A249:2020 | PN-EN 13630-1:2005 | PN-EN 13630-2:2004 | PN-EN 13630-7:2004 | PN-EN 13630-8:2004 | PN-EN 13630-9:2006 | PN-EN 13630-12:2004","categories":["other"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Physical properties:","parameters_en":[{"name":"colour and appearance"},{"name":"diameter and length"},{"name":"mass"},{"name":"water resistance Performance characteristics:"},{"name":"burning time"},{"name":"resistance to reduced and elevated temperature"},{"name":"ability to initiate, ignite, transmit detonation"},{"name":"thermal stability"}],"search_en":"Detonating cords, safety fuses Physical properties: colour and appearance diameter and length mass water resistance Performance characteristics: burning time resistance to reduced and elevated temperature ability to initiate, ignite, transmit detonation thermal stability NO-13-A222:2021 NO-13-A249:2020 | PN-EN 13630-1:2005 | PN-EN 13630-2:2004 | PN-EN 13630-7:2004 | PN-EN 13630-8:2004 | PN-EN 13630-9:2006 | PN-EN 13630-12:2004","test_object_en":"Detonating cords, safety fuses","parameters_zh":[{"name":"barwa i wygląd"},{"name":"średnica i długość"},{"name":"质量"},{"name":"wodoodporność Właściwości użytkowe:"},{"name":"czas palenia"},{"name":"odporność na obniżoną i podwyższoną temperaturę"},{"name":"zdolność do inicjowania, zapalania, przenoszenia detonacji"},{"name":"stabilność termiczna"}],"search_zh":"质量 NO-13-A222:2021 NO-13-A249:2020 | PN-EN 13630-1:2005 | PN-EN 13630-2:2004 | PN-EN 13630-7:2004 | PN-EN 13630-8:2004 | PN-EN 13630-9:2006 | PN-EN 13630-12:2004"},{"_id":"6a82ef00884ede9a1b2c4b7a","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Spłonki zapalające nakłuciowe","methodology":"Wrażliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wrażliwość","reference":"PN-V-04001:1997, pkt. 1.3.4 Procedura LBŚB.PB.41 Edycja 5 z dnia 03.03.2020","norm_bases":["PN-V-04001:1997, pkt. 1.3.4 Procedura LBŚB.PB.41 Edycja 5 z dnia 03.03.2020"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Spłonki zapalające nakłuciowe Wrażliwość PN-V-04001:1997, pkt. 1.3.4 Procedura LBŚB.PB.41 Edycja 5 z dnia 03.03.2020 Splonki zapalajace nakluciowe Wrazliwosc PN-V-04001:1997, pkt. 1.3.4 Procedura LBSB.PB.41 Edycja 5 z dnia 03.03.2020","categories":["other"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Percussion ignition primers PN-V-04001:1997, pkt. 1.3.4 Procedura LBŚB.PB.41 Edycja 5 z dnia 03.03.2020","test_object_en":"Percussion ignition primers"},{"_id":"6a82ef00884ede9a1b2c4b7b","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Spłonki pobudzające nakłuciowe","methodology":"Wrażliwość, Zdolność inicjująca","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wrażliwość, Zdolność inicjująca","reference":"Procedura LBŚB.PB.42 Edycja 5 z dnia 03.03.2020","norm_bases":["Procedura LBŚB.PB.42 Edycja 5 z dnia 03.03.2020"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Spłonki pobudzające nakłuciowe Wrażliwość, Zdolność inicjująca Procedura LBŚB.PB.42 Edycja 5 z dnia 03.03.2020 Splonki pobudzajace nakluciowe Wrazliwosc, Zdolnosc inicjujaca Procedura LBSB.PB.42 Edycja 5 z dnia 03.03.2020","categories":["other"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sensitivity, Initiating capability","search_en":"Percussion initiating primers Sensitivity, Initiating capability Procedura LBŚB.PB.42 Edycja 5 z dnia 03.03.2020","test_object_en":"Percussion initiating primers"},{"_id":"6a82ef00884ede9a1b2c4b7c","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Spłonki pobudzające płomieniowe","methodology":"Wrażliwość, Zdolność inicjująca","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wrażliwość, Zdolność inicjująca","reference":"Procedura LBŚB.PB.43 Edycja 5 z dnia 04.03.2020","norm_bases":["Procedura LBŚB.PB.43 Edycja 5 z dnia 04.03.2020"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Spłonki pobudzające płomieniowe Wrażliwość, Zdolność inicjująca Procedura LBŚB.PB.43 Edycja 5 z dnia 04.03.2020 Splonki pobudzajace plomieniowe Wrazliwosc, Zdolnosc inicjujaca Procedura LBSB.PB.43 Edycja 5 z dnia 04.03.2020","categories":["other"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sensitivity, Initiating capability","search_en":"Flame initiating primers Sensitivity, Initiating capability Procedura LBŚB.PB.43 Edycja 5 z dnia 04.03.2020","test_object_en":"Flame initiating primers"},{"_id":"6a82ef00884ede9a1b2c4b7d","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Spłonki pobudzające elektryczne","methodology":"Napięcie bezpieczne, Niezawodność działania, Zdolność inicjująca","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Napięcie bezpieczne, Niezawodność działania, Zdolność inicjująca","reference":"Procedura LBŚB.PB.44 Edycja 5 z dnia 04.03.2020","norm_bases":["Procedura LBŚB.PB.44 Edycja 5 z dnia 04.03.2020"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Spłonki pobudzające elektryczne Napięcie bezpieczne, Niezawodność działania, Zdolność inicjująca Procedura LBŚB.PB.44 Edycja 5 z dnia 04.03.2020 Splonki pobudzajace elektryczne Napiecie bezpieczne, Niezawodnosc dzialania, Zdolnosc inicjujaca Procedura LBSB.PB.44 Edycja 5 z dnia 04.03.2020","categories":["other"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safe voltage, Operational reliability, Initiating capability","search_en":"Electric initiating primers Safe voltage, Operational reliability, Initiating capability Procedura LBŚB.PB.44 Edycja 5 z dnia 04.03.2020","test_object_en":"Electric initiating primers"},{"_id":"6a82ef00884ede9a1b2c4b7e","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Zapalnikowe bezpieczniki torowe","methodology":"Siła oporu łapek bezpiecznika","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Siła oporu łapek bezpiecznika","reference":"Procedura LBŚB.PB.45 Edycja 5 z dnia 04.03.2020","norm_bases":["Procedura LBŚB.PB.45 Edycja 5 z dnia 04.03.2020"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zapalnikowe bezpieczniki torowe Siła oporu łapek bezpiecznika Procedura LBŚB.PB.45 Edycja 5 z dnia 04.03.2020 Zapalnikowe bezpieczniki torowe Sila oporu lapek bezpiecznika Procedura LBSB.PB.45 Edycja 5 z dnia 04.03.2020","categories":["other"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance force of the fuse clips","search_en":"Track detonator fuses Resistance force of the fuse clips Procedura LBŚB.PB.45 Edycja 5 z dnia 04.03.2020","test_object_en":"Track detonator fuses"},{"_id":"6a82ef00884ede9a1b2c4b7f","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe, związki chemiczne różne","methodology":"Temperatura topnienia, Temperatura rozkładu, Temperatury przejść fazowych, Ubytek masy wraz ze wzrostem temperatury, Temperatura zeszklenia za pomocą termicznej analizy różnicowej i analizy termograwimetrycznej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura topnienia, Temperatura rozkładu, Temperatury przejść fazowych, Ubytek masy wraz ze wzrostem temperatury, Temperatura zeszklenia za pomocą termicznej analizy różnicowej i analizy termograwimetrycznej","reference":"NATO STANAG 4515:2015 ed. 2 Procedura LBŚB.PB.46 Edycja 4 z dnia 30.01.2026","norm_bases":["NATO STANAG 4515:2015 ed. 2 Procedura LBŚB.PB.46 Edycja 4 z dnia 30.01.2026"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe, związki chemiczne różne Temperatura topnienia, Temperatura rozkładu, Temperatury przejść fazowych, Ubytek masy wraz ze wzrostem temperatury, Temperatura zeszklenia za pomocą termicznej analizy różnicowej i analizy termograwimetrycznej NATO STANAG 4515:2015 ed. 2 Procedura LBŚB.PB.46 Edycja 4 z dnia 30.01.2026 Materialy wybuchowe, zwiazki chemiczne rozne Temperatura topnienia, Temperatura rozkladu, Temperatury przejsc fazowych, Ubytek masy wraz ze wzrostem temperatury, Temperatura zeszklenia za pomoca termicznej analizy roznicowej i analizy termograwimetrycznej NATO STANAG 4515:2015 ed. 2 Procedura LBSB.PB.46 Edycja 4 z dnia 30.01.2026","categories":["materials"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Melting point, Decomposition temperature, Phase transition temperatures, Mass loss with increasing temperature, Glass transition temperature by differential thermal analysis and thermogravimetric analysis","search_en":"Explosives, miscellaneous chemical compounds Melting point, Decomposition temperature, Phase transition temperatures, Mass loss with increasing temperature, Glass transition temperature by differential thermal analysis and thermogravimetric analysis NATO STANAG 4515:2015 ed. 2 Procedura LBŚB.PB.46 Edycja 4 z dnia 30.01.2026","test_object_en":"Explosives, miscellaneous chemical compounds"},{"_id":"6a82ef00884ede9a1b2c4b80","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe, związki chemiczne różne","methodology":"Temperatura topnienia, Temperatura rozkładu, Temperatury przejść fazowych, Ubytek masy wraz ze wzrostem temperatury, Temperatura zeszklenia za pomocą mikrokalorymetrii skaningowej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura topnienia, Temperatura rozkładu, Temperatury przejść fazowych, Ubytek masy wraz ze wzrostem temperatury, Temperatura zeszklenia za pomocą mikrokalorymetrii skaningowej","reference":"NATO STANAG 4515:2015 ed. 2 Procedura LBŚB.PB.47 Edycja 4 z dnia 30.01.2026","norm_bases":["NATO STANAG 4515:2015 ed. 2 Procedura LBŚB.PB.47 Edycja 4 z dnia 30.01.2026"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe, związki chemiczne różne Temperatura topnienia, Temperatura rozkładu, Temperatury przejść fazowych, Ubytek masy wraz ze wzrostem temperatury, Temperatura zeszklenia za pomocą mikrokalorymetrii skaningowej NATO STANAG 4515:2015 ed. 2 Procedura LBŚB.PB.47 Edycja 4 z dnia 30.01.2026 Materialy wybuchowe, zwiazki chemiczne rozne Temperatura topnienia, Temperatura rozkladu, Temperatury przejsc fazowych, Ubytek masy wraz ze wzrostem temperatury, Temperatura zeszklenia za pomoca mikrokalorymetrii skaningowej NATO STANAG 4515:2015 ed. 2 Procedura LBSB.PB.47 Edycja 4 z dnia 30.01.2026","categories":["materials"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Melting point, Decomposition temperature, Phase transition temperatures, Mass loss with increasing temperature, Glass transition temperature by scanning microcalorimetry","search_en":"Explosives, miscellaneous chemical compounds Melting point, Decomposition temperature, Phase transition temperatures, Mass loss with increasing temperature, Glass transition temperature by scanning microcalorimetry NATO STANAG 4515:2015 ed. 2 Procedura LBŚB.PB.47 Edycja 4 z dnia 30.01.2026","test_object_en":"Explosives, miscellaneous chemical compounds"},{"_id":"6a82ef00884ede9a1b2c4b81","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Sprężyny naciskowe i naciągowe","methodology":"Obciążenie kontrolne","parameters":[{"name":"Charakterystyka sprężyny:"},{"name":"siła ściskania przy określonych wysokościach"},{"name":"siła rozciągania przy określonych długościach"}],"technique":null,"techniques":[],"computed":[],"activity":"Obciążenie kontrolne\nZakres:\nCharakterystyka sprężyny:\nsiła ściskania przy określonych wysokościach\nsiła rozciągania przy określonych długościach","reference":"PN-S-47260:1996 | PN-S-47261:1996 Procedura LBŚB.PB.50 Edycja 3 z dnia 05.03.2020","norm_bases":["PN-S-47260:1996","PN-S-47261:1996 Procedura LBŚB.PB.50 Edycja 3 z dnia 05.03.2020"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sprężyny naciskowe i naciągowe Obciążenie kontrolne\nZakres:\nCharakterystyka sprężyny:\nsiła ściskania przy określonych wysokościach\nsiła rozciągania przy określonych długościach PN-S-47260:1996 | PN-S-47261:1996 Procedura LBŚB.PB.50 Edycja 3 z dnia 05.03.2020 Sprezyny naciskowe i naciagowe Obciazenie kontrolne\nZakres:\nCharakterystyka sprezyny:\nsila sciskania przy okreslonych wysokosciach\nsila rozciagania przy okreslonych dlugosciach PN-S-47260:1996 | PN-S-47261:1996 Procedura LBSB.PB.50 Edycja 3 z dnia 05.03.2020","categories":["other"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Control load","parameters_en":[{"name":"Spring characteristic:"},{"name":"compressive force at specified heights"},{"name":"tensile force at specified lengths"}],"search_en":"Compression and extension springs Control load Spring characteristic: compressive force at specified heights tensile force at specified lengths PN-S-47260:1996 | PN-S-47261:1996 Procedura LBŚB.PB.50 Edycja 3 z dnia 05.03.2020","test_object_en":"Compression and extension springs"},{"_id":"6a82ef00884ede9a1b2c4b82","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Zapłonniki, spłonki, pobudzacze, zapalniki, zapały - elektryczne inicjatory zapłonu","methodology":"Badanie elementów środków bojowych inicjowanych elektrycznie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie elementów środków bojowych inicjowanych elektrycznie","reference":"Procedura LBŚB.PB.77 Edycja 1 z dnia 06.03.2019","norm_bases":["Procedura LBŚB.PB.77 Edycja 1 z dnia 06.03.2019"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zapłonniki, spłonki, pobudzacze, zapalniki, zapały - elektryczne inicjatory zapłonu Badanie elementów środków bojowych inicjowanych elektrycznie Procedura LBŚB.PB.77 Edycja 1 z dnia 06.03.2019 Zaplonniki, splonki, pobudzacze, zapalniki, zapaly - elektryczne inicjatory zaplonu Badanie elementow srodkow bojowych inicjowanych elektrycznie Procedura LBSB.PB.77 Edycja 1 z dnia 06.03.2019","categories":["other"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Testing of components of electrically initiated munitions","search_en":"Igniters, primers, boosters, detonators, fuse heads - electric ignition initiators Testing of components of electrically initiated munitions Procedura LBŚB.PB.77 Edycja 1 z dnia 06.03.2019","test_object_en":"Igniters, primers, boosters, detonators, fuse heads - electric ignition initiators"},{"_id":"6a82ef00884ede9a1b2c4b83","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe","methodology":"Cechy zewnętrzne wyrobów:","parameters":[{"name":"konstrukcja i stabilność"},{"name":"integralność"},{"name":"oznaczanie masy brutto"},{"name":"wymiary geometryczne"},{"name":"oznaczanie kątów"},{"name":"wytrzymałość konstrukcji wyrobów"},{"name":"odporność na bodźce mechaniczne, uderzenie i spadek"},{"name":"odporność na kondycjonowanie termiczne"},{"name":"odporność na kondycjonowanie mechaniczne *)"},{"name":"odporność na przypadkowe pobudzenie"},{"name":"wymiary, zawartość i nadruk na etykietach wyrobu i opakowań jednostkowych"},{"name":"instrukcja obsługi"},{"name":"odporność na wodę"},{"name":"odporność na bodziec ogniowy"}],"technique":null,"techniques":[],"computed":[],"activity":"Cechy zewnętrzne wyrobów:\nZakres:\nkonstrukcja i stabilność\nintegralność\noznaczanie masy brutto\nwymiary geometryczne\noznaczanie kątów\nwytrzymałość konstrukcji wyrobów\nodporność na bodźce mechaniczne, uderzenie i spadek\nodporność na kondycjonowanie termiczne\nodporność na kondycjonowanie mechaniczne *)\nodporność na przypadkowe pobudzenie\nwymiary, zawartość i nadruk na etykietach wyrobu i opakowań jednostkowych\ninstrukcja obsługi\nodporność na wodę\nodporność na bodziec ogniowy","reference":"PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03 | PN-EN 16256-5:2013-06 p. 6.12 *) | PN-EN 16261-3:2013-06 p. 6.8 *) | PN-EN 16263-4:2015-09 p. 5.7 *) | PN-EN 15947-4:2023-03 p. 6.14 *) | PN-EN 15947-5:2023-03 p. 9 *)","norm_bases":["PN-EN 16256-5:2013-06","PN-EN 16261-3:2013-06","PN-EN 16263-4:2015-09","PN-EN 15947-4:2023-03","PN-EN 15947-5:2023-03","PN-EN 16256-5:2013-06 p. 6.12 *)","PN-EN 16261-3:2013-06 p. 6.8 *)","PN-EN 16263-4:2015-09 p. 5.7 *)","PN-EN 15947-4:2023-03 p. 6.14 *)","PN-EN 15947-5:2023-03 p. 9 *)"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe Cechy zewnętrzne wyrobów:\nZakres:\nkonstrukcja i stabilność\nintegralność\noznaczanie masy brutto\nwymiary geometryczne\noznaczanie kątów\nwytrzymałość konstrukcji wyrobów\nodporność na bodźce mechaniczne, uderzenie i spadek\nodporność na kondycjonowanie termiczne\nodporność na kondycjonowanie mechaniczne *)\nodporność na przypadkowe pobudzenie\nwymiary, zawartość i nadruk na etykietach wyrobu i opakowań jednostkowych\ninstrukcja obsługi\nodporność na wodę\nodporność na bodziec ogniowy PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03 | PN-EN 16256-5:2013-06 p. 6.12 *) | PN-EN 16261-3:2013-06 p. 6.8 *) | PN-EN 16263-4:2015-09 p. 5.7 *) | PN-EN 15947-4:2023-03 p. 6.14 *) | PN-EN 15947-5:2023-03 p. 9 *) Materialy wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe Cechy zewnetrzne wyrobow:\nZakres:\nkonstrukcja i stabilnosc\nintegralnosc\noznaczanie masy brutto\nwymiary geometryczne\noznaczanie katow\nwytrzymalosc konstrukcji wyrobow\nodpornosc na bodzce mechaniczne, uderzenie i spadek\nodpornosc na kondycjonowanie termiczne\nodpornosc na kondycjonowanie mechaniczne *)\nodpornosc na przypadkowe pobudzenie\nwymiary, zawartosc i nadruk na etykietach wyrobu i opakowan jednostkowych\ninstrukcja obslugi\nodpornosc na wode\nodpornosc na bodziec ogniowy PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03 | PN-EN 16256-5:2013-06 p. 6.12 *) | PN-EN 16261-3:2013-06 p. 6.8 *) | PN-EN 16263-4:2015-09 p. 5.7 *) | PN-EN 15947-4:2023-03 p. 6.14 *) | PN-EN 15947-5:2023-03 p. 9 *)","categories":["materials"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"External features of the products:","parameters_en":[{"name":"construction and stability"},{"name":"integrity"},{"name":"determination of gross mass"},{"name":"geometric dimensions"},{"name":"determination of angles"},{"name":"strength of the product structure"},{"name":"resistance to mechanical stimuli, impact and drop"},{"name":"resistance to thermal conditioning"},{"name":"odporność na kondycjonowanie mechaniczne *)"},{"name":"resistance to accidental actuation"},{"name":"dimensions, content and printing on the labels of the product and unit packages"},{"name":"operating instructions"},{"name":"water resistance"},{"name":"resistance to fire stimulus"}],"search_en":"Pyrotechnic explosives and display pyrotechnic articles External features of the products: construction and stability integrity determination of gross mass geometric dimensions determination of angles strength of the product structure resistance to mechanical stimuli, impact and drop resistance to thermal conditioning resistance to accidental actuation dimensions, content and printing on the labels of the product and unit packages operating instructions water resistance resistance to fire stimulus PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03 | PN-EN 16256-5:2013-06 p. 6.12 *) | PN-EN 16261-3:2013-06 p. 6.8 *) | PN-EN 16263-4:2015-09 p. 5.7 *) | PN-EN 15947-4:2023-03 p. 6.14 *) | PN-EN 15947-5:2023-03 p. 9 *)","test_object_en":"Pyrotechnic explosives and display pyrotechnic articles","search_zh":"烟火药与观赏烟花制品 PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03 | PN-EN 16256-5:2013-06 p. 6.12 *) | PN-EN 16261-3:2013-06 p. 6.8 *) | PN-EN 16263-4:2015-09 p. 5.7 *) | PN-EN 15947-4:2023-03 p. 6.14 *) | PN-EN 15947-5:2023-03 p. 9 *)","test_object_zh":"烟火药与观赏烟花制品"},{"_id":"6a82ef00884ede9a1b2c4b84","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe","methodology":"Zawartość masy netto materiału wybuchowego w poszczególnych elementach wyrobu i konstrukcji wewnętrznej wyrobu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość masy netto materiału wybuchowego w poszczególnych elementach wyrobu i konstrukcji wewnętrznej wyrobu","reference":"PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","norm_bases":["PN-EN 16256-5:2013-06","PN-EN 16261-3:2013-06","PN-EN 16263-4:2015-09","PN-EN 15947-4:2023-03","PN-EN 15947-5:2023-03"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe Zawartość masy netto materiału wybuchowego w poszczególnych elementach wyrobu i konstrukcji wewnętrznej wyrobu PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03 Materialy wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe Zawartosc masy netto materialu wybuchowego w poszczegolnych elementach wyrobu i konstrukcji wewnetrznej wyrobu PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","categories":["materials"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net explosive mass content in individual components of the product and in the internal structure of the product","search_en":"Pyrotechnic explosives and display pyrotechnic articles Net explosive mass content in individual components of the product and in the internal structure of the product PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","test_object_en":"Pyrotechnic explosives and display pyrotechnic articles","search_zh":"烟火药与观赏烟花制品 PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","test_object_zh":"烟火药与观赏烟花制品"},{"_id":"6a82ef00884ede9a1b2c4b85","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe","methodology":"Poprawność mocowania lontu początkowego /systemu inicjującego:","parameters":[{"name":"siła mocowania lontu"},{"name":"trwałość zamontowania lontu"}],"technique":null,"techniques":[],"computed":[],"activity":"Poprawność mocowania lontu początkowego /systemu inicjującego:\nZakres:\nsiła mocowania lontu\ntrwałość zamontowania lontu","reference":"PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","norm_bases":["PN-EN 16256-5:2013-06","PN-EN 16261-3:2013-06","PN-EN 16263-4:2015-09","PN-EN 15947-4:2023-03","PN-EN 15947-5:2023-03"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe Poprawność mocowania lontu początkowego /systemu inicjującego:\nZakres:\nsiła mocowania lontu\ntrwałość zamontowania lontu PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03 Materialy wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe Poprawnosc mocowania lontu poczatkowego /systemu inicjujacego:\nZakres:\nsila mocowania lontu\ntrwalosc zamontowania lontu PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","categories":["materials"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Correctness of the attachment of the initiating fuse /initiation system:","parameters_en":[{"name":"fuse attachment force"},{"name":"durability of the fuse attachment"}],"search_en":"Pyrotechnic explosives and display pyrotechnic articles Correctness of the attachment of the initiating fuse /initiation system: fuse attachment force durability of the fuse attachment PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","test_object_en":"Pyrotechnic explosives and display pyrotechnic articles","search_zh":"烟火药与观赏烟花制品 PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","test_object_zh":"烟火药与观赏烟花制品"},{"_id":"6a82ef00884ede9a1b2c4b86","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe","methodology":"Czas reakcji lontu / systemu inicjującego na bodziec ogniowy","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Czas reakcji lontu / systemu inicjującego na bodziec ogniowy","reference":"PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","norm_bases":["PN-EN 16256-5:2013-06","PN-EN 16261-3:2013-06","PN-EN 16263-4:2015-09","PN-EN 15947-4:2023-03","PN-EN 15947-5:2023-03"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe Czas reakcji lontu / systemu inicjującego na bodziec ogniowy PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03 Materialy wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe Czas reakcji lontu / systemu inicjujacego na bodziec ogniowy PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","categories":["materials"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Response time of the fuse / initiating system to a fire stimulus","search_en":"Pyrotechnic explosives and display pyrotechnic articles Response time of the fuse / initiating system to a fire stimulus PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","test_object_en":"Pyrotechnic explosives and display pyrotechnic articles","search_zh":"烟火药与观赏烟花制品 PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","test_object_zh":"烟火药与观赏烟花制品"},{"_id":"6a82ef00884ede9a1b2c4b87","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe","methodology":"Pionowa stabilność wyrobu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pionowa stabilność wyrobu","reference":"PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","norm_bases":["PN-EN 16256-5:2013-06","PN-EN 16261-3:2013-06","PN-EN 16263-4:2015-09","PN-EN 15947-4:2023-03","PN-EN 15947-5:2023-03"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe Pionowa stabilność wyrobu PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03 Materialy wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe Pionowa stabilnosc wyrobu PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","categories":["materials"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Vertical stability of the product","search_en":"Pyrotechnic explosives and display pyrotechnic articles Vertical stability of the product PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","test_object_en":"Pyrotechnic explosives and display pyrotechnic articles","search_zh":"烟火药与观赏烟花制品 PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","test_object_zh":"烟火药与观赏烟花制品"},{"_id":"6a82ef00884ede9a1b2c4b88","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe","methodology":"Cechy i właściwości do oceny działania zgodnie z przeznaczeniem:","parameters":[{"name":"zadziałanie i efekty główne"},{"name":"stabilność podczas działania"},{"name":"czas opóźnienia od momentu zapalenia lontu lub układu opóźnienia"},{"name":"wysokość wzlotu przy wyrobach wzlatujących, trajektoria lotu"},{"name":"wysokość opadania palących się cząstek pirotechnicznych"},{"name":"ilość i wielkość spadających pozostałości pirotechnicznych"},{"name":"wysokość wznoszenia się palących się cząstek pirotechnicznych"},{"name":"czas palenia mieszaniny pirotechnicznej"},{"name":"kąt wznoszenia, spadku i wysokość rozerwania"}],"technique":null,"techniques":[],"computed":[],"activity":"Cechy i właściwości do oceny działania zgodnie z przeznaczeniem:\nZakres:\nzadziałanie i efekty główne\nstabilność podczas działania\nczas opóźnienia od momentu zapalenia lontu lub układu opóźnienia\nwysokość wzlotu przy wyrobach wzlatujących, trajektoria lotu\nwysokość opadania palących się cząstek pirotechnicznych\nilość i wielkość spadających pozostałości pirotechnicznych\nwysokość wznoszenia się palących się cząstek pirotechnicznych\nczas palenia mieszaniny pirotechnicznej\nkąt wznoszenia, spadku i wysokość rozerwania","reference":"PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","norm_bases":["PN-EN 16256-5:2013-06","PN-EN 16261-3:2013-06","PN-EN 16263-4:2015-09","PN-EN 15947-4:2023-03","PN-EN 15947-5:2023-03"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe Cechy i właściwości do oceny działania zgodnie z przeznaczeniem:\nZakres:\nzadziałanie i efekty główne\nstabilność podczas działania\nczas opóźnienia od momentu zapalenia lontu lub układu opóźnienia\nwysokość wzlotu przy wyrobach wzlatujących, trajektoria lotu\nwysokość opadania palących się cząstek pirotechnicznych\nilość i wielkość spadających pozostałości pirotechnicznych\nwysokość wznoszenia się palących się cząstek pirotechnicznych\nczas palenia mieszaniny pirotechnicznej\nkąt wznoszenia, spadku i wysokość rozerwania PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03 Materialy wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe Cechy i wlasciwosci do oceny dzialania zgodnie z przeznaczeniem:\nZakres:\nzadzialanie i efekty glowne\nstabilnosc podczas dzialania\nczas opoznienia od momentu zapalenia lontu lub ukladu opoznienia\nwysokosc wzlotu przy wyrobach wzlatujacych, trajektoria lotu\nwysokosc opadania palacych sie czastek pirotechnicznych\nilosc i wielkosc spadajacych pozostalosci pirotechnicznych\nwysokosc wznoszenia sie palacych sie czastek pirotechnicznych\nczas palenia mieszaniny pirotechnicznej\nkat wznoszenia, spadku i wysokosc rozerwania PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","categories":["materials"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Features and properties for the assessment of performance in accordance with the intended use:","parameters_en":[{"name":"functioning and main effects"},{"name":"stability during operation"},{"name":"delay time from the moment of ignition of the fuse or delay system"},{"name":"ascent height for rising articles, flight trajectory"},{"name":"falling height of burning pyrotechnic particles"},{"name":"quantity and size of falling pyrotechnic residues"},{"name":"rising height of burning pyrotechnic particles"},{"name":"burning time of the pyrotechnic mixture"},{"name":"angle of ascent, descent and burst height"}],"search_en":"Pyrotechnic explosives and display pyrotechnic articles Features and properties for the assessment of performance in accordance with the intended use: functioning and main effects stability during operation delay time from the moment of ignition of the fuse or delay system ascent height for rising articles, flight trajectory falling height of burning pyrotechnic particles quantity and size of falling pyrotechnic residues rising height of burning pyrotechnic particles burning time of the pyrotechnic mixture angle of ascent, descent and burst height PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","test_object_en":"Pyrotechnic explosives and display pyrotechnic articles","search_zh":"烟火药与观赏烟花制品 PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","test_object_zh":"烟火药与观赏烟花制品"},{"_id":"6a82ef00884ede9a1b2c4b89","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe","methodology":"Poziom ciśnienia akustycznego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ciśnienia akustycznego","reference":"PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","norm_bases":["PN-EN 16256-5:2013-06","PN-EN 16261-3:2013-06","PN-EN 16263-4:2015-09","PN-EN 15947-4:2023-03","PN-EN 15947-5:2023-03"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe Poziom ciśnienia akustycznego PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03 Materialy wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe Poziom cisnienia akustycznego PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","categories":["materials"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sound pressure level","search_en":"Pyrotechnic explosives and display pyrotechnic articles Sound pressure level PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","test_object_en":"Pyrotechnic explosives and display pyrotechnic articles","methodology_zh":"声压级","search_zh":"烟火药与观赏烟花制品 声压级 PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","test_object_zh":"烟火药与观赏烟花制品"},{"_id":"6a82ef00884ede9a1b2c4b8a","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe","methodology":"Wysokość wznoszenia się, kąt lotu, parametry wybuchu i zgaszenia się wyrobu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wysokość wznoszenia się, kąt lotu, parametry wybuchu i zgaszenia się wyrobu","reference":"PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","norm_bases":["PN-EN 16256-5:2013-06","PN-EN 16261-3:2013-06","PN-EN 16263-4:2015-09","PN-EN 15947-4:2023-03","PN-EN 15947-5:2023-03"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe Wysokość wznoszenia się, kąt lotu, parametry wybuchu i zgaszenia się wyrobu PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03 Materialy wybuchowe pirotechniczne i wyroby pirotechniczne widowiskowe Wysokosc wznoszenia sie, kat lotu, parametry wybuchu i zgaszenia sie wyrobu PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","categories":["materials"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Rise height, flight angle, parameters of the burst and of the extinction of the article","search_en":"Pyrotechnic explosives and display pyrotechnic articles Rise height, flight angle, parameters of the burst and of the extinction of the article PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","test_object_en":"Pyrotechnic explosives and display pyrotechnic articles","search_zh":"烟火药与观赏烟花制品 PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","test_object_zh":"烟火药与观赏烟花制品"},{"_id":"6a82ef00884ede9a1b2c4b8b","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Elementy wyrobów pirotechnicznych widowiskowych","methodology":"Wymiary geometryczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary geometryczne","reference":"PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","norm_bases":["PN-EN 16256-5:2013-06","PN-EN 16261-3:2013-06","PN-EN 16263-4:2015-09","PN-EN 15947-4:2023-03","PN-EN 15947-5:2023-03"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elementy wyrobów pirotechnicznych widowiskowych Wymiary geometryczne PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03 Elementy wyrobow pirotechnicznych widowiskowych Wymiary geometryczne PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","categories":["other"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Geometric dimensions","search_en":"Components of pyrotechnic articles for entertainment Geometric dimensions PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","test_object_en":"Components of pyrotechnic articles for entertainment","methodology_zh":"几何尺寸","search_zh":"几何尺寸 PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03"},{"_id":"6a82ef00884ede9a1b2c4b8c","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Opakowania i części pozostałe po zadziałaniu materiałów wybuchowych pirotechnicznych i wyrobów pirotechnicznych widowiskowych","methodology":"Palące się lub żarzące się cząstki, Kształt i wymiary geometryczne wyrzucanych elementów, Masa wyrzucanych elementów i odległości rozrzutu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Palące się lub żarzące się cząstki, Kształt i wymiary geometryczne wyrzucanych elementów, Masa wyrzucanych elementów i odległości rozrzutu","reference":"PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","norm_bases":["PN-EN 16256-5:2013-06","PN-EN 16261-3:2013-06","PN-EN 16263-4:2015-09","PN-EN 15947-4:2023-03","PN-EN 15947-5:2023-03"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Opakowania i części pozostałe po zadziałaniu materiałów wybuchowych pirotechnicznych i wyrobów pirotechnicznych widowiskowych Palące się lub żarzące się cząstki, Kształt i wymiary geometryczne wyrzucanych elementów, Masa wyrzucanych elementów i odległości rozrzutu PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03 Opakowania i czesci pozostale po zadzialaniu materialow wybuchowych pirotechnicznych i wyrobow pirotechnicznych widowiskowych Palace sie lub zarzace sie czastki, Ksztalt i wymiary geometryczne wyrzucanych elementow, Masa wyrzucanych elementow i odleglosci rozrzutu PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","categories":["materials"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Burning or glowing particles, Shape and geometric dimensions of ejected elements, Mass of ejected elements and scatter distances","search_en":"Packaging and parts remaining after the functioning of pyrotechnic explosives and display pyrotechnic articles Burning or glowing particles, Shape and geometric dimensions of ejected elements, Mass of ejected elements and scatter distances PN-EN 16256-5:2013-06 | PN-EN 16261-3:2013-06 | PN-EN 16263-4:2015-09 | PN-EN 15947-4:2023-03 | PN-EN 15947-5:2023-03","test_object_en":"Packaging and parts remaining after the functioning of pyrotechnic explosives and display pyrotechnic articles"},{"_id":"6a82ef00884ede9a1b2c4b8d","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Pojemniki i komory do przewozu przedmiotów niebezpiecznych","methodology":"Odporność na wybuch, Gazoszczelność","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na wybuch, Gazoszczelność","reference":"Procedura LBŚB.PB.69 Edycja 3 z dnia 10.06.2020","norm_bases":["Procedura LBŚB.PB.69 Edycja 3 z dnia 10.06.2020"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pojemniki i komory do przewozu przedmiotów niebezpiecznych Odporność na wybuch, Gazoszczelność Procedura LBŚB.PB.69 Edycja 3 z dnia 10.06.2020 Pojemniki i komory do przewozu przedmiotow niebezpiecznych Odpornosc na wybuch, Gazoszczelnosc Procedura LBSB.PB.69 Edycja 3 z dnia 10.06.2020","categories":["other"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Explosion resistance, Gas tightness","search_en":"Containers and chambers for the transport of dangerous articles Explosion resistance, Gas tightness Procedura LBŚB.PB.69 Edycja 3 z dnia 10.06.2020","test_object_en":"Containers and chambers for the transport of dangerous articles"},{"_id":"6a82ef00884ede9a1b2c4b8e","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Sprzęt i środki ochrony indywidualnej i zbiorowej - okna, drzwi, żaluzje","methodology":"Odporność na wybuch","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na wybuch","reference":"PN-EN 13123-2:2004 | PN-EN 13124-2:2004","norm_bases":["PN-EN 13123-2:2004","PN-EN 13124-2:2004"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sprzęt i środki ochrony indywidualnej i zbiorowej - okna, drzwi, żaluzje Odporność na wybuch PN-EN 13123-2:2004 | PN-EN 13124-2:2004 Sprzet i srodki ochrony indywidualnej i zbiorowej - okna, drzwi, zaluzje Odpornosc na wybuch PN-EN 13123-2:2004 | PN-EN 13124-2:2004","categories":["other"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Explosion resistance","search_en":"Personal and collective protective equipment and means - windows, doors, shutters Explosion resistance PN-EN 13123-2:2004 | PN-EN 13124-2:2004","test_object_en":"Personal and collective protective equipment and means - windows, doors, shutters"},{"_id":"6a82ef00884ede9a1b2c4b8f","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Amunicja i jej elementy, elementy rakiet","methodology":"Badania poprawności konstrukcji obiektów za pomocą rentgenowskiego systemu diagnostycznego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badania poprawności konstrukcji obiektów za pomocą rentgenowskiego systemu diagnostycznego","reference":"PN-EN 13938-5:2006 | PN-EN 13938-6:2006 Procedura LBŚB.PB.78 Edycja 1 z dnia 13.01.2021","norm_bases":["PN-EN 13938-5:2006","PN-EN 13938-6:2006 Procedura LBŚB.PB.78 Edycja 1 z dnia 13.01.2021"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Amunicja i jej elementy, elementy rakiet Badania poprawności konstrukcji obiektów za pomocą rentgenowskiego systemu diagnostycznego PN-EN 13938-5:2006 | PN-EN 13938-6:2006 Procedura LBŚB.PB.78 Edycja 1 z dnia 13.01.2021 Amunicja i jej elementy, elementy rakiet Badania poprawnosci konstrukcji obiektow za pomoca rentgenowskiego systemu diagnostycznego PN-EN 13938-5:2006 | PN-EN 13938-6:2006 Procedura LBSB.PB.78 Edycja 1 z dnia 13.01.2021","categories":["other"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Testing of the correctness of the construction of objects using an X-ray diagnostic system","search_en":"Ammunition and its components, rocket components Testing of the correctness of the construction of objects using an X-ray diagnostic system PN-EN 13938-5:2006 | PN-EN 13938-6:2006 Procedura LBŚB.PB.78 Edycja 1 z dnia 13.01.2021","test_object_en":"Ammunition and its components, rocket components"},{"_id":"6a82ef00884ede9a1b2c4b90","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Wyroby pirotechniczne -, Urządzenia zapłonowe","methodology":"Konstrukcja i budowa wyrobu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Konstrukcja i budowa wyrobu","reference":"PN-EN 16265:2016-01 pkt.. 5.1.1.; 6.3.1.; 6.3.2.","norm_bases":["PN-EN 16265:2016-01 pkt.. 5.1.1.; 6.3.1.; 6.3.2."],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby pirotechniczne -, Urządzenia zapłonowe Konstrukcja i budowa wyrobu PN-EN 16265:2016-01 pkt.. 5.1.1.; 6.3.1.; 6.3.2. Wyroby pirotechniczne -, Urzadzenia zaplonowe Konstrukcja i budowa wyrobu PN-EN 16265:2016-01 pkt.. 5.1.1.; 6.3.1.; 6.3.2.","categories":["other"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Design and construction of the product","search_en":"Pyrotechnic articles -, Ignition devices Design and construction of the product PN-EN 16265:2016-01 pkt.. 5.1.1.; 6.3.1.; 6.3.2.","test_object_en":"Pyrotechnic articles -, Ignition devices","search_zh":"烟火制品、点火装置 PN-EN 16265:2016-01 pkt.. 5.1.1.; 6.3.1.; 6.3.2.","test_object_zh":"烟火制品、点火装置"},{"_id":"6a82ef00884ede9a1b2c4b91","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Wyroby pirotechniczne -, Urządzenia zapłonowe","methodology":"Weryfikacja etykietowania i instrukcji użytkowania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Weryfikacja etykietowania i instrukcji użytkowania","reference":"PN-EN 16265:2016-01 pkt. 5.2.; 6.3.3.; 7.","norm_bases":["PN-EN 16265:2016-01 pkt. 5.2.; 6.3.3.; 7."],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby pirotechniczne -, Urządzenia zapłonowe Weryfikacja etykietowania i instrukcji użytkowania PN-EN 16265:2016-01 pkt. 5.2.; 6.3.3.; 7. Wyroby pirotechniczne -, Urzadzenia zaplonowe Weryfikacja etykietowania i instrukcji uzytkowania PN-EN 16265:2016-01 pkt. 5.2.; 6.3.3.; 7.","categories":["other"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Verification of labelling and instructions for use","search_en":"Pyrotechnic articles -, Ignition devices Verification of labelling and instructions for use PN-EN 16265:2016-01 pkt. 5.2.; 6.3.3.; 7.","test_object_en":"Pyrotechnic articles -, Ignition devices","search_zh":"烟火制品、点火装置 PN-EN 16265:2016-01 pkt. 5.2.; 6.3.3.; 7.","test_object_zh":"烟火制品、点火装置"},{"_id":"6a82ef00884ede9a1b2c4b92","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Wyroby pirotechniczne -, Urządzenia zapłonowe","methodology":"Pomiar rezystancji","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar rezystancji","reference":"PN-EN 16265:2016-01 pkt. 6.3.17.","norm_bases":["PN-EN 16265:2016-01 pkt. 6.3.17."],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby pirotechniczne -, Urządzenia zapłonowe Pomiar rezystancji PN-EN 16265:2016-01 pkt. 6.3.17. Wyroby pirotechniczne -, Urzadzenia zaplonowe Pomiar rezystancji PN-EN 16265:2016-01 pkt. 6.3.17.","categories":["other"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance measurement","search_en":"Pyrotechnic articles -, Ignition devices Resistance measurement PN-EN 16265:2016-01 pkt. 6.3.17.","test_object_en":"Pyrotechnic articles -, Ignition devices","search_zh":"烟火制品、点火装置 PN-EN 16265:2016-01 pkt. 6.3.17.","test_object_zh":"烟火制品、点火装置"},{"_id":"6a82ef00884ede9a1b2c4b93","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Wyroby pirotechniczne -, Urządzenia zapłonowe","methodology":"Stabilność termiczna","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stabilność termiczna","reference":"PN-EN 16265:2016-01 pkt. 6.3.9.","norm_bases":["PN-EN 16265:2016-01 pkt. 6.3.9."],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby pirotechniczne -, Urządzenia zapłonowe Stabilność termiczna PN-EN 16265:2016-01 pkt. 6.3.9. Wyroby pirotechniczne -, Urzadzenia zaplonowe Stabilnosc termiczna PN-EN 16265:2016-01 pkt. 6.3.9.","categories":["other"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Thermal stability","search_en":"Pyrotechnic articles -, Ignition devices Thermal stability PN-EN 16265:2016-01 pkt. 6.3.9.","test_object_en":"Pyrotechnic articles -, Ignition devices","search_zh":"烟火制品、点火装置 PN-EN 16265:2016-01 pkt. 6.3.9.","test_object_zh":"烟火制品、点火装置"},{"_id":"6a82ef00884ede9a1b2c4b94","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Wyroby pirotechniczne -, Urządzenia zapłonowe","methodology":"Wrażliwość na wstrząsy mechaniczne *)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wrażliwość na wstrząsy mechaniczne *)","reference":"PN-EN 16265:2016-01 pkt. 6.3.10. *)","norm_bases":["PN-EN 16265:2016-01 pkt. 6.3.10. *)"],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby pirotechniczne -, Urządzenia zapłonowe Wrażliwość na wstrząsy mechaniczne *) PN-EN 16265:2016-01 pkt. 6.3.10. *) Wyroby pirotechniczne -, Urzadzenia zaplonowe Wrazliwosc na wstrzasy mechaniczne *) PN-EN 16265:2016-01 pkt. 6.3.10. *)","categories":["other"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Pyrotechnic articles -, Ignition devices PN-EN 16265:2016-01 pkt. 6.3.10. *)","test_object_en":"Pyrotechnic articles -, Ignition devices","search_zh":"烟火制品、点火装置 PN-EN 16265:2016-01 pkt. 6.3.10. *)","test_object_zh":"烟火制品、点火装置"},{"_id":"6a82ef00884ede9a1b2c4b95","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Wyroby pirotechniczne -, Urządzenia zapłonowe","methodology":"Zadziałanie i efekt wyrobu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zadziałanie i efekt wyrobu","reference":"PN-EN 16265:2016-01 pkt. 6.3.6.","norm_bases":["PN-EN 16265:2016-01 pkt. 6.3.6."],"lab_section":"Laboratorium Badań Środków Bojowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby pirotechniczne -, Urządzenia zapłonowe Zadziałanie i efekt wyrobu PN-EN 16265:2016-01 pkt. 6.3.6. Wyroby pirotechniczne -, Urzadzenia zaplonowe Zadzialanie i efekt wyrobu PN-EN 16265:2016-01 pkt. 6.3.6.","categories":["other"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Functioning and effect of the article","search_en":"Pyrotechnic articles -, Ignition devices Functioning and effect of the article PN-EN 16265:2016-01 pkt. 6.3.6.","test_object_en":"Pyrotechnic articles -, Ignition devices","search_zh":"烟火制品、点火装置 PN-EN 16265:2016-01 pkt. 6.3.6.","test_object_zh":"烟火制品、点火装置"},{"_id":"6a82ef00884ede9a1b2c4b96","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Materiały i obiekty pokryte materiałami absorbującymi lub odbijającymi promieniowanie elektromagnetyczne, m. in. materiały kompozytowe, materiały hybrydowe i metamateriały lub obiekty pokryte takimi materiałami","methodology":"Częstotliwościowe charakterystyki współczynników odbicia i transmisji w zakresie częstotliwości: 10 MHz – 40 GHz oraz (75 – 110) GHz","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Częstotliwościowe charakterystyki współczynników odbicia i transmisji w zakresie częstotliwości: 10 MHz – 40 GHz oraz (75 – 110) GHz","reference":"PN-EN 50147-1:2000 IEEE 299-2006 Procedura LBEMC.PB.01 Edycja 1 z dnia 05.03.2020","norm_bases":["PN-EN 50147-1:2000 IEEE 299-2006 Procedura LBEMC.PB.01 Edycja 1 z dnia 05.03.2020"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i obiekty pokryte materiałami absorbującymi lub odbijającymi promieniowanie elektromagnetyczne, m. in. materiały kompozytowe, materiały hybrydowe i metamateriały lub obiekty pokryte takimi materiałami Częstotliwościowe charakterystyki współczynników odbicia i transmisji w zakresie częstotliwości: 10 MHz – 40 GHz oraz (75 – 110) GHz PN-EN 50147-1:2000 IEEE 299-2006 Procedura LBEMC.PB.01 Edycja 1 z dnia 05.03.2020 Materialy i obiekty pokryte materialami absorbujacymi lub odbijajacymi promieniowanie elektromagnetyczne, m. in. materialy kompozytowe, materialy hybrydowe i metamaterialy lub obiekty pokryte takimi materialami Czestotliwosciowe charakterystyki wspolczynnikow odbicia i transmisji w zakresie czestotliwosci: 10 MHz – 40 GHz oraz (75 – 110) GHz PN-EN 50147-1:2000 IEEE 299-2006 Procedura LBEMC.PB.01 Edycja 1 z dnia 05.03.2020","categories":["materials"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Materials and objects covered with materials absorbing or reflecting electromagnetic radiation, including composite materials, hybrid materials and metamaterials or objects covered with such materials PN-EN 50147-1:2000 IEEE 299-2006 Procedura LBEMC.PB.01 Edycja 1 z dnia 05.03.2020","test_object_en":"Materials and objects covered with materials absorbing or reflecting electromagnetic radiation, including composite materials, hybrid materials and metamaterials or objects covered with such materials"},{"_id":"6a82ef00884ede9a1b2c4b97","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Urządzenia o przeznaczeniu wojskowym","methodology":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:","parameters":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"napięcie zaburzeń ciągłych;"},{"name":"napięcie zaburzeń nieciągłych (trzaski) c) emisja harmonicznych prądu, d) ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery)."}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski) c) emisja harmonicznych prądu, d) ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery).","reference":"NO-06-A500:2012 pkt. 3.1, 3.2, 3.13, 3.14 NO-06-A200:2012 | MIL-STD-461F pkt. 5.4, 5.5, 5.16, 5.17 | MIL-STD-461G pkt. 5.4, 5.5, 5.17, 5.18","norm_bases":["NO-06-A500:2012 pkt. 3.1, 3.2, 3.13, 3.14 NO-06-A200:2012","MIL-STD-461F pkt. 5.4, 5.5, 5.16, 5.17","MIL-STD-461G pkt. 5.4, 5.5, 5.17, 5.18"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia o przeznaczeniu wojskowym Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski) c) emisja harmonicznych prądu, d) ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery). NO-06-A500:2012 pkt. 3.1, 3.2, 3.13, 3.14 NO-06-A200:2012 | MIL-STD-461F pkt. 5.4, 5.5, 5.16, 5.17 | MIL-STD-461G pkt. 5.4, 5.5, 5.17, 5.18 Urzadzenia o przeznaczeniu wojskowym Emisja zaburzen elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatezenie pola elektromagnetycznego w pasmie czestotliwosci 20 Hz – 40 GHz;\nmoc zaburzen w pasmie czestotliwosci 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapiecie zaburzen ciaglych;\nnapiecie zaburzen nieciaglych (trzaski) c) emisja harmonicznych pradu, d) ograniczanie zmian napiecia, wahan napiecia i migotania swiatla (flickery). NO-06-A500:2012 pkt. 3.1, 3.2, 3.13, 3.14 NO-06-A200:2012 | MIL-STD-461F pkt. 5.4, 5.5, 5.16, 5.17 | MIL-STD-461G pkt. 5.4, 5.5, 5.17, 5.18","categories":["environment"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of electromagnetic disturbances in the range of: a) radiated emission, including:","parameters_en":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"continuous disturbance voltage;"},{"name":"discontinuous disturbance voltage (clicks) c) harmonic current emission, d) limitation of voltage changes, voltage fluctuations and flicker."}],"search_en":"Equipment for military use Emission of electromagnetic disturbances in the range of: a) radiated emission, including: continuous disturbance voltage; discontinuous disturbance voltage (clicks) c) harmonic current emission, d) limitation of voltage changes, voltage fluctuations and flicker. NO-06-A500:2012 pkt. 3.1, 3.2, 3.13, 3.14 NO-06-A200:2012 | MIL-STD-461F pkt. 5.4, 5.5, 5.16, 5.17 | MIL-STD-461G pkt. 5.4, 5.5, 5.17, 5.18","test_object_en":"Equipment for military use","methodology_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括：","parameters_zh":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"连续骚扰电压；"},{"name":"断续骚扰电压（喀呖声）c) 电流谐波发射，d) 电压变化、电压波动与闪烁的限制。"}],"search_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括： 连续骚扰电压； 断续骚扰电压（喀呖声）c) 电流谐波发射，d) 电压变化、电压波动与闪烁的限制。 NO-06-A500:2012 pkt. 3.1, 3.2, 3.13, 3.14 NO-06-A200:2012 | MIL-STD-461F pkt. 5.4, 5.5, 5.16, 5.17 | MIL-STD-461G pkt. 5.4, 5.5, 5.17, 5.18"},{"_id":"6a82ef00884ede9a1b2c4b98","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Urządzenia elektryczne i elektroniczne, o maksymalnym napięciu zasilania do 400V i częstotliwości od 0Hz do 1000Hz, w tym urządzenia zasilane z sieci publicznej i/lub z baterii lub akumulatorów","methodology":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:","parameters":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"napięcie zaburzeń ciągłych;"},{"name":"napięcie zaburzeń nieciągłych (trzaski) c) emisja harmonicznych prądu, d) ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery)."}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski) c) emisja harmonicznych prądu, d) ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery).","reference":"PN-EN 61000-3-2:2014-10 | PN-EN 61000-3-2:2019-04 | PN-EN 61000-3-2:2019-04/A1:2021-08 | PN-EN 61000-3-2:2019-04/A2:2024-12 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04 | PN-EN 61000-3-3:2013-10/AC:2022-05 | PN-EN 61000-3-11:2004 | PN-EN 61000-3-11:2020-01 | PN-EN 61000-3-12:2012 | PN-EN 61000-3-12:2012/A1:2024-11 | PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 55016-2-1:2014-09/AC:2020-11 | PN-EN 55016-2-2:2011 | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 55016-2-3:2017-06/A2:2024-03","norm_bases":["PN-EN 61000-3-2:2014-10","PN-EN 61000-3-2:2019-04","PN-EN 61000-3-2:2019-04/A1:2021-08","PN-EN 61000-3-2:2019-04/A2:2024-12","PN-EN 61000-3-3:2013-10","PN-EN 61000-3-3:2013-10/A1:2019-10","PN-EN 61000-3-3:2013-10/A2:2022-04","PN-EN 61000-3-3:2013-10/AC:2022-05","PN-EN 61000-3-11:2004","PN-EN 61000-3-11:2020-01","PN-EN 61000-3-12:2012","PN-EN 61000-3-12:2012/A1:2024-11","PN-EN 55016-2-1:2014-09","PN-EN 55016-2-1:2014-09/A1:2017-12","PN-EN 55016-2-1:2014-09/AC:2020-11","PN-EN 55016-2-2:2011","PN-EN 55016-2-3:2017-06","PN-EN 55016-2-3:2017-06/A1:2020-01","PN-EN 55016-2-3:2017-06/A2:2024-03"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia elektryczne i elektroniczne, o maksymalnym napięciu zasilania do 400V i częstotliwości od 0Hz do 1000Hz, w tym urządzenia zasilane z sieci publicznej i/lub z baterii lub akumulatorów Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski) c) emisja harmonicznych prądu, d) ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery). PN-EN 61000-3-2:2014-10 | PN-EN 61000-3-2:2019-04 | PN-EN 61000-3-2:2019-04/A1:2021-08 | PN-EN 61000-3-2:2019-04/A2:2024-12 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04 | PN-EN 61000-3-3:2013-10/AC:2022-05 | PN-EN 61000-3-11:2004 | PN-EN 61000-3-11:2020-01 | PN-EN 61000-3-12:2012 | PN-EN 61000-3-12:2012/A1:2024-11 | PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 55016-2-1:2014-09/AC:2020-11 | PN-EN 55016-2-2:2011 | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 55016-2-3:2017-06/A2:2024-03 Urzadzenia elektryczne i elektroniczne, o maksymalnym napieciu zasilania do 400V i czestotliwosci od 0Hz do 1000Hz, w tym urzadzenia zasilane z sieci publicznej i/lub z baterii lub akumulatorow Emisja zaburzen elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatezenie pola elektromagnetycznego w pasmie czestotliwosci 20 Hz – 40 GHz;\nmoc zaburzen w pasmie czestotliwosci 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapiecie zaburzen ciaglych;\nnapiecie zaburzen nieciaglych (trzaski) c) emisja harmonicznych pradu, d) ograniczanie zmian napiecia, wahan napiecia i migotania swiatla (flickery). PN-EN 61000-3-2:2014-10 | PN-EN 61000-3-2:2019-04 | PN-EN 61000-3-2:2019-04/A1:2021-08 | PN-EN 61000-3-2:2019-04/A2:2024-12 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04 | PN-EN 61000-3-3:2013-10/AC:2022-05 | PN-EN 61000-3-11:2004 | PN-EN 61000-3-11:2020-01 | PN-EN 61000-3-12:2012 | PN-EN 61000-3-12:2012/A1:2024-11 | PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 55016-2-1:2014-09/AC:2020-11 | PN-EN 55016-2-2:2011 | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 55016-2-3:2017-06/A2:2024-03","categories":["environment","electronics"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of electromagnetic disturbances in the range of: a) radiated emission, including:","parameters_en":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"continuous disturbance voltage;"},{"name":"discontinuous disturbance voltage (clicks) c) harmonic current emission, d) limitation of voltage changes, voltage fluctuations and flicker."}],"search_en":"Emission of electromagnetic disturbances in the range of: a) radiated emission, including: continuous disturbance voltage; discontinuous disturbance voltage (clicks) c) harmonic current emission, d) limitation of voltage changes, voltage fluctuations and flicker. PN-EN 61000-3-2:2014-10 | PN-EN 61000-3-2:2019-04 | PN-EN 61000-3-2:2019-04/A1:2021-08 | PN-EN 61000-3-2:2019-04/A2:2024-12 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04 | PN-EN 61000-3-3:2013-10/AC:2022-05 | PN-EN 61000-3-11:2004 | PN-EN 61000-3-11:2020-01 | PN-EN 61000-3-12:2012 | PN-EN 61000-3-12:2012/A1:2024-11 | PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 55016-2-1:2014-09/AC:2020-11 | PN-EN 55016-2-2:2011 | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 55016-2-3:2017-06/A2:2024-03","methodology_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括：","parameters_zh":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"连续骚扰电压；"},{"name":"断续骚扰电压（喀呖声）c) 电流谐波发射，d) 电压变化、电压波动与闪烁的限制。"}],"search_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括： 连续骚扰电压； 断续骚扰电压（喀呖声）c) 电流谐波发射，d) 电压变化、电压波动与闪烁的限制。 PN-EN 61000-3-2:2014-10 | PN-EN 61000-3-2:2019-04 | PN-EN 61000-3-2:2019-04/A1:2021-08 | PN-EN 61000-3-2:2019-04/A2:2024-12 | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN 61000-3-3:2013-10/A2:2022-04 | PN-EN 61000-3-3:2013-10/AC:2022-05 | PN-EN 61000-3-11:2004 | PN-EN 61000-3-11:2020-01 | PN-EN 61000-3-12:2012 | PN-EN 61000-3-12:2012/A1:2024-11 | PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | PN-EN 55016-2-1:2014-09/AC:2020-11 | PN-EN 55016-2-2:2011 | PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | PN-EN 55016-2-3:2017-06/A2:2024-03"},{"_id":"6a82ef00884ede9a1b2c4b99","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Przemysłowe, medyczne i naukowe (PMN) urządzenia o częstotliwości radiowej","methodology":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:","parameters":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"napięcie zaburzeń ciągłych;"},{"name":"napięcie zaburzeń nieciągłych (trzaski) c) emisja harmonicznych prądu, d) ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery)."}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski) c) emisja harmonicznych prądu, d) ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery).","reference":"PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","norm_bases":["PN-EN 55011:2016-05","PN-EN 55011:2016-05/A1:2017-06","PN-EN 55011:2016-05/A11:2020-07","PN-EN 55011:2016-05/A2:2021-08"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przemysłowe, medyczne i naukowe (PMN) urządzenia o częstotliwości radiowej Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski) c) emisja harmonicznych prądu, d) ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery). PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08 Przemyslowe, medyczne i naukowe (PMN) urzadzenia o czestotliwosci radiowej Emisja zaburzen elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatezenie pola elektromagnetycznego w pasmie czestotliwosci 20 Hz – 40 GHz;\nmoc zaburzen w pasmie czestotliwosci 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapiecie zaburzen ciaglych;\nnapiecie zaburzen nieciaglych (trzaski) c) emisja harmonicznych pradu, d) ograniczanie zmian napiecia, wahan napiecia i migotania swiatla (flickery). PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","categories":["environment"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of electromagnetic disturbances in the range of: a) radiated emission, including:","parameters_en":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"continuous disturbance voltage;"},{"name":"discontinuous disturbance voltage (clicks) c) harmonic current emission, d) limitation of voltage changes, voltage fluctuations and flicker."}],"search_en":"Industrial, scientific and medical (ISM) radio-frequency equipment Emission of electromagnetic disturbances in the range of: a) radiated emission, including: continuous disturbance voltage; discontinuous disturbance voltage (clicks) c) harmonic current emission, d) limitation of voltage changes, voltage fluctuations and flicker. PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","test_object_en":"Industrial, scientific and medical (ISM) radio-frequency equipment","methodology_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括：","parameters_zh":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"连续骚扰电压；"},{"name":"断续骚扰电压（喀呖声）c) 电流谐波发射，d) 电压变化、电压波动与闪烁的限制。"}],"search_zh":"工业、医疗与科学（ISM）射频设备 电磁骚扰发射，范围为：a) 辐射发射，其中包括： 连续骚扰电压； 断续骚扰电压（喀呖声）c) 电流谐波发射，d) 电压变化、电压波动与闪烁的限制。 PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A11:2020-07 | PN-EN 55011:2016-05/A2:2021-08","test_object_zh":"工业、医疗与科学（ISM）射频设备"},{"_id":"6a82ef00884ede9a1b2c4b9a","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Emisja w środowiskach: mieszkalnym, handlowym i lekko uprzemysłowionym","methodology":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:","parameters":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"napięcie zaburzeń ciągłych;"},{"name":"napięcie zaburzeń nieciągłych (trzaski) c) emisja harmonicznych prądu, d) ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery)."}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski) c) emisja harmonicznych prądu, d) ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery).","reference":"PN-EN 61000-6-3:2008 | PN-EN 61000-6-3:2008/A1:2012 | PN-EN 61000-6-3:2021-08","norm_bases":["PN-EN 61000-6-3:2008","PN-EN 61000-6-3:2008/A1:2012","PN-EN 61000-6-3:2021-08"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Emisja w środowiskach: mieszkalnym, handlowym i lekko uprzemysłowionym Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski) c) emisja harmonicznych prądu, d) ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery). PN-EN 61000-6-3:2008 | PN-EN 61000-6-3:2008/A1:2012 | PN-EN 61000-6-3:2021-08 Emisja w srodowiskach: mieszkalnym, handlowym i lekko uprzemyslowionym Emisja zaburzen elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatezenie pola elektromagnetycznego w pasmie czestotliwosci 20 Hz – 40 GHz;\nmoc zaburzen w pasmie czestotliwosci 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapiecie zaburzen ciaglych;\nnapiecie zaburzen nieciaglych (trzaski) c) emisja harmonicznych pradu, d) ograniczanie zmian napiecia, wahan napiecia i migotania swiatla (flickery). PN-EN 61000-6-3:2008 | PN-EN 61000-6-3:2008/A1:2012 | PN-EN 61000-6-3:2021-08","categories":["environment"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of electromagnetic disturbances in the range of: a) radiated emission, including:","parameters_en":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"continuous disturbance voltage;"},{"name":"discontinuous disturbance voltage (clicks) c) harmonic current emission, d) limitation of voltage changes, voltage fluctuations and flicker."}],"search_en":"Emission of electromagnetic disturbances in the range of: a) radiated emission, including: continuous disturbance voltage; discontinuous disturbance voltage (clicks) c) harmonic current emission, d) limitation of voltage changes, voltage fluctuations and flicker. PN-EN 61000-6-3:2008 | PN-EN 61000-6-3:2008/A1:2012 | PN-EN 61000-6-3:2021-08","methodology_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括：","parameters_zh":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"连续骚扰电压；"},{"name":"断续骚扰电压（喀呖声）c) 电流谐波发射，d) 电压变化、电压波动与闪烁的限制。"}],"search_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括： 连续骚扰电压； 断续骚扰电压（喀呖声）c) 电流谐波发射，d) 电压变化、电压波动与闪烁的限制。 PN-EN 61000-6-3:2008 | PN-EN 61000-6-3:2008/A1:2012 | PN-EN 61000-6-3:2021-08"},{"_id":"6a82ef00884ede9a1b2c4b9b","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Emisja w środowiskach przemysłowych","methodology":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:","parameters":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"napięcie zaburzeń ciągłych;"},{"name":"napięcie zaburzeń nieciągłych (trzaski) c) emisja harmonicznych prądu, d) ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery)."}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski) c) emisja harmonicznych prądu, d) ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery).","reference":"PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN 61000-6-4:2019-12","norm_bases":["PN-EN 61000-6-4:2008","PN-EN 61000-6-4:2008/A1:2012","PN-EN 61000-6-4:2019-12"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Emisja w środowiskach przemysłowych Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski) c) emisja harmonicznych prądu, d) ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery). PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN 61000-6-4:2019-12 Emisja w srodowiskach przemyslowych Emisja zaburzen elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatezenie pola elektromagnetycznego w pasmie czestotliwosci 20 Hz – 40 GHz;\nmoc zaburzen w pasmie czestotliwosci 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapiecie zaburzen ciaglych;\nnapiecie zaburzen nieciaglych (trzaski) c) emisja harmonicznych pradu, d) ograniczanie zmian napiecia, wahan napiecia i migotania swiatla (flickery). PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN 61000-6-4:2019-12","categories":["environment"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of electromagnetic disturbances in the range of: a) radiated emission, including:","parameters_en":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"continuous disturbance voltage;"},{"name":"discontinuous disturbance voltage (clicks) c) harmonic current emission, d) limitation of voltage changes, voltage fluctuations and flicker."}],"search_en":"Emission of electromagnetic disturbances in the range of: a) radiated emission, including: continuous disturbance voltage; discontinuous disturbance voltage (clicks) c) harmonic current emission, d) limitation of voltage changes, voltage fluctuations and flicker. PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN 61000-6-4:2019-12","methodology_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括：","parameters_zh":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"连续骚扰电压；"},{"name":"断续骚扰电压（喀呖声）c) 电流谐波发射，d) 电压变化、电压波动与闪烁的限制。"}],"search_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括： 连续骚扰电压； 断续骚扰电压（喀呖声）c) 电流谐波发射，d) 电压变化、电压波动与闪烁的限制。 PN-EN 61000-6-4:2008 | PN-EN 61000-6-4:2008/A1:2012 | PN-EN 61000-6-4:2019-12"},{"_id":"6a82ef00884ede9a1b2c4b9c","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Elektryczne przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia","methodology":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:","parameters":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"napięcie zaburzeń ciągłych;"},{"name":"napięcie zaburzeń nieciągłych (trzaski) c) emisja harmonicznych prądu, d) ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery)."}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski) c) emisja harmonicznych prądu, d) ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery).","reference":"PN-EN 55014-1:2017-06 | PN-EN 55014-1:2021-08","norm_bases":["PN-EN 55014-1:2017-06","PN-EN 55014-1:2021-08"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczne przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski) c) emisja harmonicznych prądu, d) ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery). PN-EN 55014-1:2017-06 | PN-EN 55014-1:2021-08 Elektryczne przyrzady powszechnego uzytku, narzedzia elektryczne i podobne urzadzenia Emisja zaburzen elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatezenie pola elektromagnetycznego w pasmie czestotliwosci 20 Hz – 40 GHz;\nmoc zaburzen w pasmie czestotliwosci 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapiecie zaburzen ciaglych;\nnapiecie zaburzen nieciaglych (trzaski) c) emisja harmonicznych pradu, d) ograniczanie zmian napiecia, wahan napiecia i migotania swiatla (flickery). PN-EN 55014-1:2017-06 | PN-EN 55014-1:2021-08","categories":["environment"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of electromagnetic disturbances in the range of: a) radiated emission, including:","parameters_en":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"continuous disturbance voltage;"},{"name":"discontinuous disturbance voltage (clicks) c) harmonic current emission, d) limitation of voltage changes, voltage fluctuations and flicker."}],"search_en":"Electrical household appliances, electric tools and similar apparatus Emission of electromagnetic disturbances in the range of: a) radiated emission, including: continuous disturbance voltage; discontinuous disturbance voltage (clicks) c) harmonic current emission, d) limitation of voltage changes, voltage fluctuations and flicker. PN-EN 55014-1:2017-06 | PN-EN 55014-1:2021-08","test_object_en":"Electrical household appliances, electric tools and similar apparatus","methodology_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括：","parameters_zh":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"连续骚扰电压；"},{"name":"断续骚扰电压（喀呖声）c) 电流谐波发射，d) 电压变化、电压波动与闪烁的限制。"}],"search_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括： 连续骚扰电压； 断续骚扰电压（喀呖声）c) 电流谐波发射，d) 电压变化、电压波动与闪烁的限制。 PN-EN 55014-1:2017-06 | PN-EN 55014-1:2021-08"},{"_id":"6a82ef00884ede9a1b2c4b9d","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Urządzenia informatyczne i techniki biurowej, Urządzenia do komunikacji z wykorzystaniem sieci zasilającej niskiego napięcia, Urządzenia multimedialne","methodology":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:","parameters":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"napięcie zaburzeń ciągłych;"},{"name":"napięcie zaburzeń nieciągłych (trzaski) c) emisja harmonicznych prądu, d) ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery)."}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski) c) emisja harmonicznych prądu, d) ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery).","reference":"PN-EN 50561-1:2013-12 | PN-EN 50561-1:2013-12/Ap1:2018-11 | PN-EN 50561-1:2013-12/AC:2015-01 | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","norm_bases":["PN-EN 50561-1:2013-12","PN-EN 50561-1:2013-12/Ap1:2018-11","PN-EN 50561-1:2013-12/AC:2015-01","PN-EN 55032:2015-09","PN-EN 55032:2015-09/AC:2016-09","PN-EN 55032:2015-09/Ap1:2017-12","PN-EN 55032:2015-09/A11:2020-07","PN-EN 55032:2015-09/A1:2021-05"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia informatyczne i techniki biurowej, Urządzenia do komunikacji z wykorzystaniem sieci zasilającej niskiego napięcia, Urządzenia multimedialne Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski) c) emisja harmonicznych prądu, d) ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery). PN-EN 50561-1:2013-12 | PN-EN 50561-1:2013-12/Ap1:2018-11 | PN-EN 50561-1:2013-12/AC:2015-01 | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05 Urzadzenia informatyczne i techniki biurowej, Urzadzenia do komunikacji z wykorzystaniem sieci zasilajacej niskiego napiecia, Urzadzenia multimedialne Emisja zaburzen elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatezenie pola elektromagnetycznego w pasmie czestotliwosci 20 Hz – 40 GHz;\nmoc zaburzen w pasmie czestotliwosci 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapiecie zaburzen ciaglych;\nnapiecie zaburzen nieciaglych (trzaski) c) emisja harmonicznych pradu, d) ograniczanie zmian napiecia, wahan napiecia i migotania swiatla (flickery). PN-EN 50561-1:2013-12 | PN-EN 50561-1:2013-12/Ap1:2018-11 | PN-EN 50561-1:2013-12/AC:2015-01 | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","categories":["environment"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of electromagnetic disturbances in the range of: a) radiated emission, including:","parameters_en":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"continuous disturbance voltage;"},{"name":"discontinuous disturbance voltage (clicks) c) harmonic current emission, d) limitation of voltage changes, voltage fluctuations and flicker."}],"search_en":"Information technology and office equipment, Equipment for communication using low voltage power supply networks, Multimedia equipment Emission of electromagnetic disturbances in the range of: a) radiated emission, including: continuous disturbance voltage; discontinuous disturbance voltage (clicks) c) harmonic current emission, d) limitation of voltage changes, voltage fluctuations and flicker. PN-EN 50561-1:2013-12 | PN-EN 50561-1:2013-12/Ap1:2018-11 | PN-EN 50561-1:2013-12/AC:2015-01 | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05","test_object_en":"Information technology and office equipment, Equipment for communication using low voltage power supply networks, Multimedia equipment","methodology_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括：","parameters_zh":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"连续骚扰电压；"},{"name":"断续骚扰电压（喀呖声）c) 电流谐波发射，d) 电压变化、电压波动与闪烁的限制。"}],"search_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括： 连续骚扰电压； 断续骚扰电压（喀呖声）c) 电流谐波发射，d) 电压变化、电压波动与闪烁的限制。 PN-EN 50561-1:2013-12 | PN-EN 50561-1:2013-12/Ap1:2018-11 | PN-EN 50561-1:2013-12/AC:2015-01 | PN-EN 55032:2015-09 | PN-EN 55032:2015-09/AC:2016-09 | PN-EN 55032:2015-09/Ap1:2017-12 | PN-EN 55032:2015-09/A11:2020-07 | PN-EN 55032:2015-09/A1:2021-05"},{"_id":"6a82ef00884ede9a1b2c4b9e","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Środowisko kolejowe, Aparatura instalowana na pojazdach kolejowych, tramwajowych, metrze i trolejbusach. Aparatura sterowania ruchem. Aparatura telekomunikacyjna. Aparatura energetyczna","methodology":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:","parameters":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"napięcie zaburzeń ciągłych;"},{"name":"napięcie zaburzeń nieciągłych (trzaski),","range":"do 32 A;"}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski), do 32 A;","reference":"PN-EN 50121-2:2017-06 | PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 | PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","norm_bases":["PN-EN 50121-2:2017-06","PN-EN 50121-3-2:2017-04","PN-EN 50121-3-2:2017-04/A1:2019-07","PN-EN 50121-4:2017-04","PN-EN 50121-4:2017-04/A1:2019-07","PN-EN 50121-5:2017-05","PN-EN 50121-5:2017-05/A1:2019-07"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko kolejowe, Aparatura instalowana na pojazdach kolejowych, tramwajowych, metrze i trolejbusach. Aparatura sterowania ruchem. Aparatura telekomunikacyjna. Aparatura energetyczna Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski), do 32 A; PN-EN 50121-2:2017-06 | PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 | PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07 Srodowisko kolejowe, Aparatura instalowana na pojazdach kolejowych, tramwajowych, metrze i trolejbusach. Aparatura sterowania ruchem. Aparatura telekomunikacyjna. Aparatura energetyczna Emisja zaburzen elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatezenie pola elektromagnetycznego w pasmie czestotliwosci 20 Hz – 40 GHz;\nmoc zaburzen w pasmie czestotliwosci 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapiecie zaburzen ciaglych;\nnapiecie zaburzen nieciaglych (trzaski), do 32 A; PN-EN 50121-2:2017-06 | PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 | PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","categories":["environment","automotive"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of electromagnetic disturbances in the range of: a) radiated emission, including:","parameters_en":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"continuous disturbance voltage;"},{"name":"discontinuous disturbance voltage (clicks),","range":"do 32 A;"}],"search_en":"Railway environment, Apparatus installed on railway vehicles, trams, metro and trolleybuses. Signalling apparatus. Telecommunications apparatus. Power apparatus Emission of electromagnetic disturbances in the range of: a) radiated emission, including: continuous disturbance voltage; discontinuous disturbance voltage (clicks), PN-EN 50121-2:2017-06 | PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 | PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","test_object_en":"Railway environment, Apparatus installed on railway vehicles, trams, metro and trolleybuses. Signalling apparatus. Telecommunications apparatus. Power apparatus","methodology_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括：","parameters_zh":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"连续骚扰电压；"},{"name":"断续骚扰电压（喀呖声），","range":"do 32 A;"}],"search_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括： 连续骚扰电压； 断续骚扰电压（喀呖声）， PN-EN 50121-2:2017-06 | PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 | PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07"},{"_id":"6a82ef00884ede9a1b2c4b9f","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Wyposażenie elektryczne do pomiarów, sterowania i użytku w laboratoriach","methodology":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:","parameters":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"napięcie zaburzeń ciągłych;"},{"name":"napięcie zaburzeń nieciągłych (trzaski),","range":"do 32 A;"}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski), do 32 A;","reference":"PN-EN 61326-1:2013-06 | PN-EN 61326-1:2021-10 | PN-EN 61326-2-1:2013-07 | PN-EN 61326-2-1:2021-10 | PN-EN 61326-2-2:2013-07 | PN-EN 61326-2-2:2021-11","norm_bases":["PN-EN 61326-1:2013-06","PN-EN 61326-1:2021-10","PN-EN 61326-2-1:2013-07","PN-EN 61326-2-1:2021-10","PN-EN 61326-2-2:2013-07","PN-EN 61326-2-2:2021-11"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyposażenie elektryczne do pomiarów, sterowania i użytku w laboratoriach Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski), do 32 A; PN-EN 61326-1:2013-06 | PN-EN 61326-1:2021-10 | PN-EN 61326-2-1:2013-07 | PN-EN 61326-2-1:2021-10 | PN-EN 61326-2-2:2013-07 | PN-EN 61326-2-2:2021-11 Wyposazenie elektryczne do pomiarow, sterowania i uzytku w laboratoriach Emisja zaburzen elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatezenie pola elektromagnetycznego w pasmie czestotliwosci 20 Hz – 40 GHz;\nmoc zaburzen w pasmie czestotliwosci 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapiecie zaburzen ciaglych;\nnapiecie zaburzen nieciaglych (trzaski), do 32 A; PN-EN 61326-1:2013-06 | PN-EN 61326-1:2021-10 | PN-EN 61326-2-1:2013-07 | PN-EN 61326-2-1:2021-10 | PN-EN 61326-2-2:2013-07 | PN-EN 61326-2-2:2021-11","categories":["environment"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of electromagnetic disturbances in the range of: a) radiated emission, including:","parameters_en":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"continuous disturbance voltage;"},{"name":"discontinuous disturbance voltage (clicks),","range":"do 32 A;"}],"search_en":"Electrical equipment for measurement, control and laboratory use Emission of electromagnetic disturbances in the range of: a) radiated emission, including: continuous disturbance voltage; discontinuous disturbance voltage (clicks), PN-EN 61326-1:2013-06 | PN-EN 61326-1:2021-10 | PN-EN 61326-2-1:2013-07 | PN-EN 61326-2-1:2021-10 | PN-EN 61326-2-2:2013-07 | PN-EN 61326-2-2:2021-11","test_object_en":"Electrical equipment for measurement, control and laboratory use","methodology_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括：","parameters_zh":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"连续骚扰电压；"},{"name":"断续骚扰电压（喀呖声），","range":"do 32 A;"}],"search_zh":"测量、控制与实验室用电气设备 电磁骚扰发射，范围为：a) 辐射发射，其中包括： 连续骚扰电压； 断续骚扰电压（喀呖声）， PN-EN 61326-1:2013-06 | PN-EN 61326-1:2021-10 | PN-EN 61326-2-1:2013-07 | PN-EN 61326-2-1:2021-10 | PN-EN 61326-2-2:2013-07 | PN-EN 61326-2-2:2021-11","test_object_zh":"测量、控制与实验室用电气设备"},{"_id":"6a82ef00884ede9a1b2c4ba0","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Przekaźniki czasowe do zastosowań przemysłowych i mieszkaniowych","methodology":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:","parameters":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"napięcie zaburzeń ciągłych;"},{"name":"napięcie zaburzeń nieciągłych (trzaski),","range":"do 32 A;"}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski), do 32 A;","reference":"PN-EN 61812-1:2011","norm_bases":["PN-EN 61812-1:2011"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przekaźniki czasowe do zastosowań przemysłowych i mieszkaniowych Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski), do 32 A; PN-EN 61812-1:2011 Przekazniki czasowe do zastosowan przemyslowych i mieszkaniowych Emisja zaburzen elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatezenie pola elektromagnetycznego w pasmie czestotliwosci 20 Hz – 40 GHz;\nmoc zaburzen w pasmie czestotliwosci 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapiecie zaburzen ciaglych;\nnapiecie zaburzen nieciaglych (trzaski), do 32 A; PN-EN 61812-1:2011","categories":["environment"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of electromagnetic disturbances in the range of: a) radiated emission, including:","parameters_en":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"continuous disturbance voltage;"},{"name":"discontinuous disturbance voltage (clicks),","range":"do 32 A;"}],"search_en":"Time relays for industrial and residential applications Emission of electromagnetic disturbances in the range of: a) radiated emission, including: continuous disturbance voltage; discontinuous disturbance voltage (clicks), PN-EN 61812-1:2011","test_object_en":"Time relays for industrial and residential applications","methodology_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括：","parameters_zh":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"连续骚扰电压；"},{"name":"断续骚扰电压（喀呖声），","range":"do 32 A;"}],"search_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括： 连续骚扰电压； 断续骚扰电压（喀呖声）， PN-EN 61812-1:2011"},{"_id":"6a82ef00884ede9a1b2c4ba1","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Systemy bezprzerwowego zasilania (UPS)","methodology":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:","parameters":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"napięcie zaburzeń ciągłych;"},{"name":"napięcie zaburzeń nieciągłych (trzaski),","range":"do 32 A;"}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski), do 32 A;","reference":"PN-EN 62040-2:2008 | PN-EN 62040-2:2019-02","norm_bases":["PN-EN 62040-2:2008","PN-EN 62040-2:2019-02"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Systemy bezprzerwowego zasilania (UPS) Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski), do 32 A; PN-EN 62040-2:2008 | PN-EN 62040-2:2019-02 Systemy bezprzerwowego zasilania (UPS) Emisja zaburzen elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatezenie pola elektromagnetycznego w pasmie czestotliwosci 20 Hz – 40 GHz;\nmoc zaburzen w pasmie czestotliwosci 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapiecie zaburzen ciaglych;\nnapiecie zaburzen nieciaglych (trzaski), do 32 A; PN-EN 62040-2:2008 | PN-EN 62040-2:2019-02","categories":["environment"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of electromagnetic disturbances in the range of: a) radiated emission, including:","parameters_en":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"continuous disturbance voltage;"},{"name":"discontinuous disturbance voltage (clicks),","range":"do 32 A;"}],"search_en":"Uninterruptible power systems (UPS) Emission of electromagnetic disturbances in the range of: a) radiated emission, including: continuous disturbance voltage; discontinuous disturbance voltage (clicks), PN-EN 62040-2:2008 | PN-EN 62040-2:2019-02","test_object_en":"Uninterruptible power systems (UPS)","methodology_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括：","parameters_zh":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"连续骚扰电压；"},{"name":"断续骚扰电压（喀呖声），","range":"do 32 A;"}],"search_zh":"不间断电源系统（UPS） 电磁骚扰发射，范围为：a) 辐射发射，其中包括： 连续骚扰电压； 断续骚扰电压（喀呖声）， PN-EN 62040-2:2008 | PN-EN 62040-2:2019-02","test_object_zh":"不间断电源系统（UPS）"},{"_id":"6a82ef00884ede9a1b2c4ba2","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Ciepłomierze","methodology":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:","parameters":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"napięcie zaburzeń ciągłych;"},{"name":"napięcie zaburzeń nieciągłych (trzaski),","range":"do 32 A;"}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski), do 32 A;","reference":"PN-EN 1434-4:2016-01","norm_bases":["PN-EN 1434-4:2016-01"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ciepłomierze Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski), do 32 A; PN-EN 1434-4:2016-01 Cieplomierze Emisja zaburzen elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatezenie pola elektromagnetycznego w pasmie czestotliwosci 20 Hz – 40 GHz;\nmoc zaburzen w pasmie czestotliwosci 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapiecie zaburzen ciaglych;\nnapiecie zaburzen nieciaglych (trzaski), do 32 A; PN-EN 1434-4:2016-01","categories":["environment"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of electromagnetic disturbances in the range of: a) radiated emission, including:","parameters_en":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"continuous disturbance voltage;"},{"name":"discontinuous disturbance voltage (clicks),","range":"do 32 A;"}],"search_en":"Heat meters Emission of electromagnetic disturbances in the range of: a) radiated emission, including: continuous disturbance voltage; discontinuous disturbance voltage (clicks), PN-EN 1434-4:2016-01","test_object_en":"Heat meters","methodology_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括：","parameters_zh":[{"name":"natężenie pola elektromagnetycznego w paśmie częstotliwości 20 Hz – 40 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"连续骚扰电压；"},{"name":"断续骚扰电压（喀呖声），","range":"do 32 A;"}],"search_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括： 连续骚扰电压； 断续骚扰电压（喀呖声）， PN-EN 1434-4:2016-01"},{"_id":"6a82ef00884ede9a1b2c4ba3","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Urządzenia sieci telekomunikacyjnej. Urządzenia komutacyjne. Urządzenia transmisyjne. Zasilacze zewnętrzne do telefonów ruchomych współpracujących z cyfrowym, ruchomym i przenośnym terminalem radiokomunikacyjnym sieci komórkowej wyposażone we wtyk typu USB zdefiniowany w dokumencie M/455","methodology":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:","parameters":[{"name":"natężenie pola elektromagne-tycznego w paśmie często-tliwości 30 MHz – 6 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"napięcie zaburzeń ciągłych;"},{"name":"napięcie zaburzeń nieciągłych (trzaski),","range":"do 32 A;"},{"name":"emisja harmonicznych prądu,","range":"do 63 A;"},{"name":"ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery), do 32 A / fazę."}],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagne-tycznego w paśmie często-tliwości 30 MHz – 6 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski), do 32 A;\nemisja harmonicznych prądu, do 63 A;\nograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery), do 32 A / fazę.","reference":"PN-ETSI EN 301 489-34 V1.4.1:2011","norm_bases":["PN-ETSI EN 301 489-34 V1.4.1:2011"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia sieci telekomunikacyjnej. Urządzenia komutacyjne. Urządzenia transmisyjne. Zasilacze zewnętrzne do telefonów ruchomych współpracujących z cyfrowym, ruchomym i przenośnym terminalem radiokomunikacyjnym sieci komórkowej wyposażone we wtyk typu USB zdefiniowany w dokumencie M/455 Emisja zaburzeń elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatężenie pola elektromagne-tycznego w paśmie często-tliwości 30 MHz – 6 GHz;\nmoc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapięcie zaburzeń ciągłych;\nnapięcie zaburzeń nieciągłych (trzaski), do 32 A;\nemisja harmonicznych prądu, do 63 A;\nograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery), do 32 A / fazę. PN-ETSI EN 301 489-34 V1.4.1:2011 Urzadzenia sieci telekomunikacyjnej. Urzadzenia komutacyjne. Urzadzenia transmisyjne. Zasilacze zewnetrzne do telefonow ruchomych wspolpracujacych z cyfrowym, ruchomym i przenosnym terminalem radiokomunikacyjnym sieci komorkowej wyposazone we wtyk typu USB zdefiniowany w dokumencie M/455 Emisja zaburzen elektromagnetycznych w zakresie: a) emisji promieniowanej, w tym:\nZakres:\nnatezenie pola elektromagne-tycznego w pasmie czesto-tliwosci 30 MHz – 6 GHz;\nmoc zaburzen w pasmie czestotliwosci 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:\nnapiecie zaburzen ciaglych;\nnapiecie zaburzen nieciaglych (trzaski), do 32 A;\nemisja harmonicznych pradu, do 63 A;\nograniczanie zmian napiecia, wahan napiecia i migotania swiatla (flickery), do 32 A / faze. PN-ETSI EN 301 489-34 V1.4.1:2011","categories":["environment"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of electromagnetic disturbances in the range of: a) radiated emission, including:","parameters_en":[{"name":"natężenie pola elektromagne-tycznego w paśmie często-tliwości 30 MHz – 6 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"continuous disturbance voltage;"},{"name":"discontinuous disturbance voltage (clicks),","range":"do 32 A;"},{"name":"current harmonics emission,","range":"do 63 A;"},{"name":"limitation of voltage changes, voltage fluctuations and flicker, up to 32 A / phase."}],"search_en":"Telecommunication network equipment. Switching equipment. Transmission equipment. External power supplies for mobile phones working with a digital mobile and portable radiocommunication terminal of a cellular network, fitted with a USB plug as defined in document M/455 Emission of electromagnetic disturbances in the range of: a) radiated emission, including: continuous disturbance voltage; discontinuous disturbance voltage (clicks), current harmonics emission, limitation of voltage changes, voltage fluctuations and flicker, up to 32 A / phase. PN-ETSI EN 301 489-34 V1.4.1:2011","test_object_en":"Telecommunication network equipment. Switching equipment. Transmission equipment. External power supplies for mobile phones working with a digital mobile and portable radiocommunication terminal of a cellular network, fitted with a USB plug as defined in document M/455","methodology_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括：","parameters_zh":[{"name":"natężenie pola elektromagne-tycznego w paśmie często-tliwości 30 MHz – 6 GHz;"},{"name":"moc zaburzeń w paśmie częstotliwości 30 MHz – 1000 MHz; b) emisji przewodzonej, w tym:"},{"name":"连续骚扰电压；"},{"name":"断续骚扰电压（喀呖声），","range":"do 32 A;"},{"name":"emisja harmonicznych prądu,","range":"do 63 A;"},{"name":"ograniczanie zmian napięcia, wahań napięcia i migotania światła (flickery), do 32 A / fazę."}],"search_zh":"电磁骚扰发射，范围为：a) 辐射发射，其中包括： 连续骚扰电压； 断续骚扰电压（喀呖声）， PN-ETSI EN 301 489-34 V1.4.1:2011"},{"_id":"6a82ef00884ede9a1b2c4ba4","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Urządzenia o przeznaczeniu wojskowym, Urządzenia elektryczne i elektroniczne, o maksymalnym napięciu zasilania do 400V i częstotliwości od 0Hz do 1000Hz, w tym urządzenia zasilane z sieci publicznej i/lub z baterii lub akumulatorów","methodology":"Odporność na:","parameters":[{"name":"promieniowane pole elektromagnetyczne;"},{"name":"zaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;"},{"name":"narażenia przewodzone (przewody zasilające wprowadzane do kabli, pobudzanie impulsowe, tłumiona fala sinusoidalna)"},{"name":"narażenia promieniowe (pole magnetyczne, pole elektryczne)"},{"name":"wyładowania elektrostatyczne (personal born electrostatic discharge);"},{"name":"serie szybkich elektrycznych stanów przejściowych","range":"do 63 A;"},{"name":"udary elektryczne","range":"do 63 A;"},{"name":"pole magnetyczne 50 Hz;"},{"name":"impulsowe pole magnetyczne;"},{"name":"zapady i zaniki napięcia AC i DC","range":"do 32 A;"},{"name":"harmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;"},{"name":"wahania napięcia;"},{"name":"asymetrię napięcia;"},{"name":"zmiany częstotliwości sieci zasilającej;"},{"name":"narażenia EMC pod kątem bezpieczeństwa urządzeń"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nnarażenia przewodzone (przewody zasilające wprowadzane do kabli, pobudzanie impulsowe, tłumiona fala sinusoidalna)\nnarażenia promieniowe (pole magnetyczne, pole elektryczne)\nwyładowania elektrostatyczne (personal born electrostatic discharge);\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej;\nnarażenia EMC pod kątem bezpieczeństwa urządzeń","reference":"NO-06-A211:2016 NO-06-A212:2015 NO-10-A217:2012 NO-06-A500:2012 pkt. 3.4, 3.9, 3.10, 3.11, 3.16, 3.17 NO-06-A200:2012 | MIL-STD-461F pkt. 5.7, 5.13, 5.14, 5,15, 5.19 i 5.20 | MIL-STD-461G pkt. 5.7, 5.12, 5.13, 5,14, 5.16, 5.20 i 5.21 | PN-EN 61000-4-2:2011 | PN-EN 61000-4-3:2007+A1:2008 +A2:2011+ IS1:2009 | PN-EN 61000-4-3:2021-06 | PN-EN 61000-4-4:2013-05 | PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01 | PN-EN 61000-4-6:2014-04 | PN-EN 61000-4-6:2024-03 | PN-EN 61000-4-8:2010 | PN-EN 61000-4-9:2016-11 | PN-EN 61000-4-11:2007 | PN-EN 61000-4-11:2007/A1 :2017-09 | PN-EN IEC 61000-4-11:2020-11 | PN-EN IEC 61000-4-11:2020-11/AC:2020-12 | PN-EN IEC 61000-4-11:2020-11/AC:2023-01 | PN-EN 61000-4-13:2007 | PN-EN 61000-4-13:2007/A1:2010 | PN-EN 61000-4-13:2007/A2:2016-05 | PN-EN 61000-4-14:2002 | PN-EN 61000-4-14:2002/A1:2006 | PN-EN 61000-4-14:2002/A2:2010 | PN-EN 61000-4-27:2004 | PN-EN 61000-4-27:2004/A1:2011 | PN-EN 61000-4-28:2004 | PN-EN 61000-4-28:2004/A1:2006 | PN-EN 61000-4-28:2004/A2:2011 | PN-EN 61000-4-29:2004 | PN-EN 61000-4-34:2009 | PN-EN 61000-4-34:2009/A1:2010","norm_bases":["NO-06-A211:2016 NO-06-A212:2015 NO-10-A217:2012 NO-06-A500:2012 pkt. 3.4, 3.9, 3.10, 3.11, 3.16, 3.17 NO-06-A200:2012","MIL-STD-461F pkt. 5.7, 5.13, 5.14, 5,15, 5.19 i 5.20","MIL-STD-461G pkt. 5.7, 5.12, 5.13, 5,14, 5.16, 5.20 i 5.21","PN-EN 61000-4-2:2011","PN-EN 61000-4-3:2007+A1:2008 +A2:2011+ IS1:2009","PN-EN 61000-4-3:2021-06","PN-EN 61000-4-4:2013-05","PN-EN 61000-4-5:2014-10","PN-EN 61000-4-5:2014-10/A1:2018-01","PN-EN 61000-4-6:2014-04","PN-EN 61000-4-6:2024-03","PN-EN 61000-4-8:2010","PN-EN 61000-4-9:2016-11","PN-EN 61000-4-11:2007","PN-EN 61000-4-11:2007/A1 :2017-09","PN-EN IEC 61000-4-11:2020-11","PN-EN IEC 61000-4-11:2020-11/AC:2020-12","PN-EN IEC 61000-4-11:2020-11/AC:2023-01","PN-EN 61000-4-13:2007","PN-EN 61000-4-13:2007/A1:2010","PN-EN 61000-4-13:2007/A2:2016-05","PN-EN 61000-4-14:2002","PN-EN 61000-4-14:2002/A1:2006","PN-EN 61000-4-14:2002/A2:2010","PN-EN 61000-4-27:2004","PN-EN 61000-4-27:2004/A1:2011","PN-EN 61000-4-28:2004","PN-EN 61000-4-28:2004/A1:2006","PN-EN 61000-4-28:2004/A2:2011","PN-EN 61000-4-29:2004","PN-EN 61000-4-34:2009","PN-EN 61000-4-34:2009/A1:2010"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia o przeznaczeniu wojskowym, Urządzenia elektryczne i elektroniczne, o maksymalnym napięciu zasilania do 400V i częstotliwości od 0Hz do 1000Hz, w tym urządzenia zasilane z sieci publicznej i/lub z baterii lub akumulatorów Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nnarażenia przewodzone (przewody zasilające wprowadzane do kabli, pobudzanie impulsowe, tłumiona fala sinusoidalna)\nnarażenia promieniowe (pole magnetyczne, pole elektryczne)\nwyładowania elektrostatyczne (personal born electrostatic discharge);\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej;\nnarażenia EMC pod kątem bezpieczeństwa urządzeń NO-06-A211:2016 NO-06-A212:2015 NO-10-A217:2012 NO-06-A500:2012 pkt. 3.4, 3.9, 3.10, 3.11, 3.16, 3.17 NO-06-A200:2012 | MIL-STD-461F pkt. 5.7, 5.13, 5.14, 5,15, 5.19 i 5.20 | MIL-STD-461G pkt. 5.7, 5.12, 5.13, 5,14, 5.16, 5.20 i 5.21 | PN-EN 61000-4-2:2011 | PN-EN 61000-4-3:2007+A1:2008 +A2:2011+ IS1:2009 | PN-EN 61000-4-3:2021-06 | PN-EN 61000-4-4:2013-05 | PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01 | PN-EN 61000-4-6:2014-04 | PN-EN 61000-4-6:2024-03 | PN-EN 61000-4-8:2010 | PN-EN 61000-4-9:2016-11 | PN-EN 61000-4-11:2007 | PN-EN 61000-4-11:2007/A1 :2017-09 | PN-EN IEC 61000-4-11:2020-11 | PN-EN IEC 61000-4-11:2020-11/AC:2020-12 | PN-EN IEC 61000-4-11:2020-11/AC:2023-01 | PN-EN 61000-4-13:2007 | PN-EN 61000-4-13:2007/A1:2010 | PN-EN 61000-4-13:2007/A2:2016-05 | PN-EN 61000-4-14:2002 | PN-EN 61000-4-14:2002/A1:2006 | PN-EN 61000-4-14:2002/A2:2010 | PN-EN 61000-4-27:2004 | PN-EN 61000-4-27:2004/A1:2011 | PN-EN 61000-4-28:2004 | PN-EN 61000-4-28:2004/A1:2006 | PN-EN 61000-4-28:2004/A2:2011 | PN-EN 61000-4-29:2004 | PN-EN 61000-4-34:2009 | PN-EN 61000-4-34:2009/A1:2010 Urzadzenia o przeznaczeniu wojskowym, Urzadzenia elektryczne i elektroniczne, o maksymalnym napieciu zasilania do 400V i czestotliwosci od 0Hz do 1000Hz, w tym urzadzenia zasilane z sieci publicznej i/lub z baterii lub akumulatorow Odpornosc na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o czestotliwosci radiowej;\nnarazenia przewodzone (przewody zasilajace wprowadzane do kabli, pobudzanie impulsowe, tlumiona fala sinusoidalna)\nnarazenia promieniowe (pole magnetyczne, pole elektryczne)\nwyladowania elektrostatyczne (personal born electrostatic discharge);\nserie szybkich elektrycznych stanow przejsciowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napiecia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnalami sieciowymi w przylaczu zasilajacym pradu przemiennego;\nwahania napiecia;\nasymetrie napiecia;\nzmiany czestotliwosci sieci zasilajacej;\nnarazenia EMC pod katem bezpieczenstwa urzadzen NO-06-A211:2016 NO-06-A212:2015 NO-10-A217:2012 NO-06-A500:2012 pkt. 3.4, 3.9, 3.10, 3.11, 3.16, 3.17 NO-06-A200:2012 | MIL-STD-461F pkt. 5.7, 5.13, 5.14, 5,15, 5.19 i 5.20 | MIL-STD-461G pkt. 5.7, 5.12, 5.13, 5,14, 5.16, 5.20 i 5.21 | PN-EN 61000-4-2:2011 | PN-EN 61000-4-3:2007+A1:2008 +A2:2011+ IS1:2009 | PN-EN 61000-4-3:2021-06 | PN-EN 61000-4-4:2013-05 | PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01 | PN-EN 61000-4-6:2014-04 | PN-EN 61000-4-6:2024-03 | PN-EN 61000-4-8:2010 | PN-EN 61000-4-9:2016-11 | PN-EN 61000-4-11:2007 | PN-EN 61000-4-11:2007/A1 :2017-09 | PN-EN IEC 61000-4-11:2020-11 | PN-EN IEC 61000-4-11:2020-11/AC:2020-12 | PN-EN IEC 61000-4-11:2020-11/AC:2023-01 | PN-EN 61000-4-13:2007 | PN-EN 61000-4-13:2007/A1:2010 | PN-EN 61000-4-13:2007/A2:2016-05 | PN-EN 61000-4-14:2002 | PN-EN 61000-4-14:2002/A1:2006 | PN-EN 61000-4-14:2002/A2:2010 | PN-EN 61000-4-27:2004 | PN-EN 61000-4-27:2004/A1:2011 | PN-EN 61000-4-28:2004 | PN-EN 61000-4-28:2004/A1:2006 | PN-EN 61000-4-28:2004/A2:2011 | PN-EN 61000-4-29:2004 | PN-EN 61000-4-34:2009 | PN-EN 61000-4-34:2009/A1:2010","categories":["electronics"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to:","parameters_en":[{"name":"radiated electromagnetic field;"},{"name":"conducted disturbances induced by radio-frequency fields;"},{"name":"conducted tests (supply conductors introduced into cables, pulse excitation, damped oscillatory wave)"},{"name":"radiated tests (magnetic field, electric field)"},{"name":"electrostatic discharges (personal born electrostatic discharge);"},{"name":"electrical fast transient/burst","range":"do 63 A;"},{"name":"electrical surges","range":"do 63 A;"},{"name":"50 Hz magnetic field;"},{"name":"pulse magnetic field;"},{"name":"voltage dips and interruptions AC and DC","range":"do 32 A;"},{"name":"harmonics and interharmonics including mains signalling at a.c. power port;"},{"name":"voltage fluctuations;"},{"name":"voltage unbalance;"},{"name":"changes of the power supply frequency;"},{"name":"EMC immunity tests with regard to equipment safety"}],"search_en":"Resistance to: radiated electromagnetic field; conducted disturbances induced by radio-frequency fields; conducted tests (supply conductors introduced into cables, pulse excitation, damped oscillatory wave) radiated tests (magnetic field, electric field) electrostatic discharges (personal born electrostatic discharge); electrical fast transient/burst electrical surges 50 Hz magnetic field; pulse magnetic field; voltage dips and interruptions AC and DC harmonics and interharmonics including mains signalling at a.c. power port; voltage fluctuations; voltage unbalance; changes of the power supply frequency; EMC immunity tests with regard to equipment safety NO-06-A211:2016 NO-06-A212:2015 NO-10-A217:2012 NO-06-A500:2012 pkt. 3.4, 3.9, 3.10, 3.11, 3.16, 3.17 NO-06-A200:2012 | MIL-STD-461F pkt. 5.7, 5.13, 5.14, 5,15, 5.19 i 5.20 | MIL-STD-461G pkt. 5.7, 5.12, 5.13, 5,14, 5.16, 5.20 i 5.21 | PN-EN 61000-4-2:2011 | PN-EN 61000-4-3:2007+A1:2008 +A2:2011+ IS1:2009 | PN-EN 61000-4-3:2021-06 | PN-EN 61000-4-4:2013-05 | PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01 | PN-EN 61000-4-6:2014-04 | PN-EN 61000-4-6:2024-03 | PN-EN 61000-4-8:2010 | PN-EN 61000-4-9:2016-11 | PN-EN 61000-4-11:2007 | PN-EN 61000-4-11:2007/A1 :2017-09 | PN-EN IEC 61000-4-11:2020-11 | PN-EN IEC 61000-4-11:2020-11/AC:2020-12 | PN-EN IEC 61000-4-11:2020-11/AC:2023-01 | PN-EN 61000-4-13:2007 | PN-EN 61000-4-13:2007/A1:2010 | PN-EN 61000-4-13:2007/A2:2016-05 | PN-EN 61000-4-14:2002 | PN-EN 61000-4-14:2002/A1:2006 | PN-EN 61000-4-14:2002/A2:2010 | PN-EN 61000-4-27:2004 | PN-EN 61000-4-27:2004/A1:2011 | PN-EN 61000-4-28:2004 | PN-EN 61000-4-28:2004/A1:2006 | PN-EN 61000-4-28:2004/A2:2011 | PN-EN 61000-4-29:2004 | PN-EN 61000-4-34:2009 | PN-EN 61000-4-34:2009/A1:2010","methodology_zh":"耐受性：","search_zh":"耐受性： 辐射电磁场； 射频场感应的传导骚扰； 传导抗扰度（引入电缆的馈电导线、脉冲激励、阻尼正弦波） 辐射抗扰度（磁场、电场） 电快速瞬变脉冲群 浪涌（冲击） 50 Hz 工频磁场； 脉冲磁场； 交流与直流电压暂降与短时中断 交流供电接入点的谐波、间谐波及电网信号； 电压波动； 电压不平衡； 供电网频率变化； 设备安全性方面的电磁兼容抗扰度 NO-06-A211:2016 NO-06-A212:2015 NO-10-A217:2012 NO-06-A500:2012 pkt. 3.4, 3.9, 3.10, 3.11, 3.16, 3.17 NO-06-A200:2012 | MIL-STD-461F pkt. 5.7, 5.13, 5.14, 5,15, 5.19 i 5.20 | MIL-STD-461G pkt. 5.7, 5.12, 5.13, 5,14, 5.16, 5.20 i 5.21 | PN-EN 61000-4-2:2011 | PN-EN 61000-4-3:2007+A1:2008 +A2:2011+ IS1:2009 | PN-EN 61000-4-3:2021-06 | PN-EN 61000-4-4:2013-05 | PN-EN 61000-4-5:2014-10 | PN-EN 61000-4-5:2014-10/A1:2018-01 | PN-EN 61000-4-6:2014-04 | PN-EN 61000-4-6:2024-03 | PN-EN 61000-4-8:2010 | PN-EN 61000-4-9:2016-11 | PN-EN 61000-4-11:2007 | PN-EN 61000-4-11:2007/A1 :2017-09 | PN-EN IEC 61000-4-11:2020-11 | PN-EN IEC 61000-4-11:2020-11/AC:2020-12 | PN-EN IEC 61000-4-11:2020-11/AC:2023-01 | PN-EN 61000-4-13:2007 | PN-EN 61000-4-13:2007/A1:2010 | PN-EN 61000-4-13:2007/A2:2016-05 | PN-EN 61000-4-14:2002 | PN-EN 61000-4-14:2002/A1:2006 | PN-EN 61000-4-14:2002/A2:2010 | PN-EN 61000-4-27:2004 | PN-EN 61000-4-27:2004/A1:2011 | PN-EN 61000-4-28:2004 | PN-EN 61000-4-28:2004/A1:2006 | PN-EN 61000-4-28:2004/A2:2011 | PN-EN 61000-4-29:2004 | PN-EN 61000-4-34:2009 | PN-EN 61000-4-34:2009/A1:2010","parameters_zh":[{"name":"辐射电磁场；"},{"name":"射频场感应的传导骚扰；"},{"name":"传导抗扰度（引入电缆的馈电导线、脉冲激励、阻尼正弦波）"},{"name":"辐射抗扰度（磁场、电场）"},{"name":"wyładowania elektrostatyczne (personal born electrostatic discharge);"},{"name":"电快速瞬变脉冲群","range":"do 63 A;"},{"name":"浪涌（冲击）","range":"do 63 A;"},{"name":"50 Hz 工频磁场；"},{"name":"脉冲磁场；"},{"name":"交流与直流电压暂降与短时中断","range":"do 32 A;"},{"name":"交流供电接入点的谐波、间谐波及电网信号；"},{"name":"电压波动；"},{"name":"电压不平衡；"},{"name":"供电网频率变化；"},{"name":"设备安全性方面的电磁兼容抗扰度"}]},{"_id":"6a82ef00884ede9a1b2c4ba5","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Odporność w środowiskach: mieszkalnym, handlowym i lekko uprzemysłowionym, Odporność w środowiskach przemysłowych","methodology":"Odporność na:","parameters":[{"name":"promieniowane pole elektromagnetyczne;"},{"name":"zaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;"},{"name":"narażenia przewodzone (przewody zasilające wprowadzane do kabli, pobudzanie impulsowe, tłumiona fala sinusoidalna)"},{"name":"narażenia promieniowe (pole magnetyczne, pole elektryczne)"},{"name":"wyładowania elektrostatyczne;"},{"name":"serie szybkich elektrycznych stanów przejściowych","range":"do 63 A;"},{"name":"udary elektryczne","range":"do 63 A;"},{"name":"pole magnetyczne 50 Hz;"},{"name":"impulsowe pole magnetyczne;"},{"name":"zapady i zaniki napięcia AC i DC","range":"do 32 A;"},{"name":"harmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;"},{"name":"wahania napięcia;"},{"name":"asymetrię napięcia;"},{"name":"zmiany częstotliwości sieci zasilającej;"},{"name":"narażenia EMC pod kątem bezpieczeństwa urządzeń"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nnarażenia przewodzone (przewody zasilające wprowadzane do kabli, pobudzanie impulsowe, tłumiona fala sinusoidalna)\nnarażenia promieniowe (pole magnetyczne, pole elektryczne)\nwyładowania elektrostatyczne;\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej;\nnarażenia EMC pod kątem bezpieczeństwa urządzeń","reference":"PN-EN 61000-6-1:2008 | PN-EN 61000-6-1:2019-03 | PN-EN 61000-6-2:2008 | PN-EN 61000-6-2:2019-12","norm_bases":["PN-EN 61000-6-1:2008","PN-EN 61000-6-1:2019-03","PN-EN 61000-6-2:2008","PN-EN 61000-6-2:2019-12"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odporność w środowiskach: mieszkalnym, handlowym i lekko uprzemysłowionym, Odporność w środowiskach przemysłowych Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nnarażenia przewodzone (przewody zasilające wprowadzane do kabli, pobudzanie impulsowe, tłumiona fala sinusoidalna)\nnarażenia promieniowe (pole magnetyczne, pole elektryczne)\nwyładowania elektrostatyczne;\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej;\nnarażenia EMC pod kątem bezpieczeństwa urządzeń PN-EN 61000-6-1:2008 | PN-EN 61000-6-1:2019-03 | PN-EN 61000-6-2:2008 | PN-EN 61000-6-2:2019-12 Odpornosc w srodowiskach: mieszkalnym, handlowym i lekko uprzemyslowionym, Odpornosc w srodowiskach przemyslowych Odpornosc na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o czestotliwosci radiowej;\nnarazenia przewodzone (przewody zasilajace wprowadzane do kabli, pobudzanie impulsowe, tlumiona fala sinusoidalna)\nnarazenia promieniowe (pole magnetyczne, pole elektryczne)\nwyladowania elektrostatyczne;\nserie szybkich elektrycznych stanow przejsciowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napiecia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnalami sieciowymi w przylaczu zasilajacym pradu przemiennego;\nwahania napiecia;\nasymetrie napiecia;\nzmiany czestotliwosci sieci zasilajacej;\nnarazenia EMC pod katem bezpieczenstwa urzadzen PN-EN 61000-6-1:2008 | PN-EN 61000-6-1:2019-03 | PN-EN 61000-6-2:2008 | PN-EN 61000-6-2:2019-12","categories":["electronics","environment"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to:","parameters_en":[{"name":"radiated electromagnetic field;"},{"name":"conducted disturbances induced by radio-frequency fields;"},{"name":"conducted tests (supply conductors introduced into cables, pulse excitation, damped oscillatory wave)"},{"name":"radiated tests (magnetic field, electric field)"},{"name":"electrostatic discharges;"},{"name":"electrical fast transient/burst","range":"do 63 A;"},{"name":"electrical surges","range":"do 63 A;"},{"name":"50 Hz magnetic field;"},{"name":"pulse magnetic field;"},{"name":"voltage dips and interruptions AC and DC","range":"do 32 A;"},{"name":"harmonics and interharmonics including mains signalling at a.c. power port;"},{"name":"voltage fluctuations;"},{"name":"voltage unbalance;"},{"name":"changes of the power supply frequency;"},{"name":"EMC immunity tests with regard to equipment safety"}],"search_en":"Resistance to: radiated electromagnetic field; conducted disturbances induced by radio-frequency fields; conducted tests (supply conductors introduced into cables, pulse excitation, damped oscillatory wave) radiated tests (magnetic field, electric field) electrostatic discharges; electrical fast transient/burst electrical surges 50 Hz magnetic field; pulse magnetic field; voltage dips and interruptions AC and DC harmonics and interharmonics including mains signalling at a.c. power port; voltage fluctuations; voltage unbalance; changes of the power supply frequency; EMC immunity tests with regard to equipment safety PN-EN 61000-6-1:2008 | PN-EN 61000-6-1:2019-03 | PN-EN 61000-6-2:2008 | PN-EN 61000-6-2:2019-12","methodology_zh":"耐受性：","search_zh":"耐受性： 辐射电磁场； 射频场感应的传导骚扰； 传导抗扰度（引入电缆的馈电导线、脉冲激励、阻尼正弦波） 辐射抗扰度（磁场、电场） 静电放电； 电快速瞬变脉冲群 浪涌（冲击） 50 Hz 工频磁场； 脉冲磁场； 交流与直流电压暂降与短时中断 交流供电接入点的谐波、间谐波及电网信号； 电压波动； 电压不平衡； 供电网频率变化； 设备安全性方面的电磁兼容抗扰度 PN-EN 61000-6-1:2008 | PN-EN 61000-6-1:2019-03 | PN-EN 61000-6-2:2008 | PN-EN 61000-6-2:2019-12","parameters_zh":[{"name":"辐射电磁场；"},{"name":"射频场感应的传导骚扰；"},{"name":"传导抗扰度（引入电缆的馈电导线、脉冲激励、阻尼正弦波）"},{"name":"辐射抗扰度（磁场、电场）"},{"name":"静电放电；"},{"name":"电快速瞬变脉冲群","range":"do 63 A;"},{"name":"浪涌（冲击）","range":"do 63 A;"},{"name":"50 Hz 工频磁场；"},{"name":"脉冲磁场；"},{"name":"交流与直流电压暂降与短时中断","range":"do 32 A;"},{"name":"交流供电接入点的谐波、间谐波及电网信号；"},{"name":"电压波动；"},{"name":"电压不平衡；"},{"name":"供电网频率变化；"},{"name":"设备安全性方面的电磁兼容抗扰度"}]},{"_id":"6a82ef00884ede9a1b2c4ba6","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Elektryczne przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia","methodology":"Odporność na:","parameters":[{"name":"promieniowane pole elektromagnetyczne;"},{"name":"zaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;"},{"name":"narażenia przewodzone (przewody zasilające wprowadzane do kabli, pobudzanie impulsowe, tłumiona fala sinusoidalna)"},{"name":"narażenia promieniowe (pole magnetyczne, pole elektryczne)"},{"name":"wyładowania elektrostatyczne;"},{"name":"serie szybkich elektrycznych stanów przejściowych","range":"do 63 A;"},{"name":"udary elektryczne","range":"do 63 A;"},{"name":"pole magnetyczne 50 Hz;"},{"name":"impulsowe pole magnetyczne;"},{"name":"zapady i zaniki napięcia AC i DC","range":"do 32 A;"},{"name":"harmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;"},{"name":"wahania napięcia;"},{"name":"asymetrię napięcia;"},{"name":"zmiany częstotliwości sieci zasilającej;"},{"name":"narażenia EMC pod kątem bezpieczeństwa urządzeń"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nnarażenia przewodzone (przewody zasilające wprowadzane do kabli, pobudzanie impulsowe, tłumiona fala sinusoidalna)\nnarażenia promieniowe (pole magnetyczne, pole elektryczne)\nwyładowania elektrostatyczne;\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej;\nnarażenia EMC pod kątem bezpieczeństwa urządzeń","reference":"PN-EN 55014-2:2015-06 | PN-EN 55014-2:2021-08","norm_bases":["PN-EN 55014-2:2015-06","PN-EN 55014-2:2021-08"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Elektryczne przyrządy powszechnego użytku, narzędzia elektryczne i podobne urządzenia Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nnarażenia przewodzone (przewody zasilające wprowadzane do kabli, pobudzanie impulsowe, tłumiona fala sinusoidalna)\nnarażenia promieniowe (pole magnetyczne, pole elektryczne)\nwyładowania elektrostatyczne;\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej;\nnarażenia EMC pod kątem bezpieczeństwa urządzeń PN-EN 55014-2:2015-06 | PN-EN 55014-2:2021-08 Elektryczne przyrzady powszechnego uzytku, narzedzia elektryczne i podobne urzadzenia Odpornosc na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o czestotliwosci radiowej;\nnarazenia przewodzone (przewody zasilajace wprowadzane do kabli, pobudzanie impulsowe, tlumiona fala sinusoidalna)\nnarazenia promieniowe (pole magnetyczne, pole elektryczne)\nwyladowania elektrostatyczne;\nserie szybkich elektrycznych stanow przejsciowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napiecia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnalami sieciowymi w przylaczu zasilajacym pradu przemiennego;\nwahania napiecia;\nasymetrie napiecia;\nzmiany czestotliwosci sieci zasilajacej;\nnarazenia EMC pod katem bezpieczenstwa urzadzen PN-EN 55014-2:2015-06 | PN-EN 55014-2:2021-08","categories":["electronics"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to:","parameters_en":[{"name":"radiated electromagnetic field;"},{"name":"conducted disturbances induced by radio-frequency fields;"},{"name":"conducted tests (supply conductors introduced into cables, pulse excitation, damped oscillatory wave)"},{"name":"radiated tests (magnetic field, electric field)"},{"name":"electrostatic discharges;"},{"name":"electrical fast transient/burst","range":"do 63 A;"},{"name":"electrical surges","range":"do 63 A;"},{"name":"50 Hz magnetic field;"},{"name":"pulse magnetic field;"},{"name":"voltage dips and interruptions AC and DC","range":"do 32 A;"},{"name":"harmonics and interharmonics including mains signalling at a.c. power port;"},{"name":"voltage fluctuations;"},{"name":"voltage unbalance;"},{"name":"changes of the power supply frequency;"},{"name":"EMC immunity tests with regard to equipment safety"}],"search_en":"Electrical household appliances, electric tools and similar apparatus Resistance to: radiated electromagnetic field; conducted disturbances induced by radio-frequency fields; conducted tests (supply conductors introduced into cables, pulse excitation, damped oscillatory wave) radiated tests (magnetic field, electric field) electrostatic discharges; electrical fast transient/burst electrical surges 50 Hz magnetic field; pulse magnetic field; voltage dips and interruptions AC and DC harmonics and interharmonics including mains signalling at a.c. power port; voltage fluctuations; voltage unbalance; changes of the power supply frequency; EMC immunity tests with regard to equipment safety PN-EN 55014-2:2015-06 | PN-EN 55014-2:2021-08","test_object_en":"Electrical household appliances, electric tools and similar apparatus","methodology_zh":"耐受性：","search_zh":"耐受性： 辐射电磁场； 射频场感应的传导骚扰； 传导抗扰度（引入电缆的馈电导线、脉冲激励、阻尼正弦波） 辐射抗扰度（磁场、电场） 静电放电； 电快速瞬变脉冲群 浪涌（冲击） 50 Hz 工频磁场； 脉冲磁场； 交流与直流电压暂降与短时中断 交流供电接入点的谐波、间谐波及电网信号； 电压波动； 电压不平衡； 供电网频率变化； 设备安全性方面的电磁兼容抗扰度 PN-EN 55014-2:2015-06 | PN-EN 55014-2:2021-08","parameters_zh":[{"name":"辐射电磁场；"},{"name":"射频场感应的传导骚扰；"},{"name":"传导抗扰度（引入电缆的馈电导线、脉冲激励、阻尼正弦波）"},{"name":"辐射抗扰度（磁场、电场）"},{"name":"静电放电；"},{"name":"电快速瞬变脉冲群","range":"do 63 A;"},{"name":"浪涌（冲击）","range":"do 63 A;"},{"name":"50 Hz 工频磁场；"},{"name":"脉冲磁场；"},{"name":"交流与直流电压暂降与短时中断","range":"do 32 A;"},{"name":"交流供电接入点的谐波、间谐波及电网信号；"},{"name":"电压波动；"},{"name":"电压不平衡；"},{"name":"供电网频率变化；"},{"name":"设备安全性方面的电磁兼容抗扰度"}]},{"_id":"6a82ef00884ede9a1b2c4ba7","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Urządzenia multimedialne","methodology":"Odporność na:","parameters":[{"name":"promieniowane pole elektromagnetyczne;"},{"name":"zaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;"},{"name":"narażenia przewodzone (przewody zasilające wprowadzane do kabli, pobudzanie impulsowe, tłumiona fala sinusoidalna)"},{"name":"narażenia promieniowe (pole magnetyczne, pole elektryczne)"},{"name":"wyładowania elektrostatyczne;"},{"name":"serie szybkich elektrycznych stanów przejściowych","range":"do 63 A;"},{"name":"udary elektryczne","range":"do 63 A;"},{"name":"pole magnetyczne 50 Hz;"},{"name":"impulsowe pole magnetyczne;"},{"name":"zapady i zaniki napięcia AC i DC","range":"do 32 A;"},{"name":"harmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;"},{"name":"wahania napięcia;"},{"name":"asymetrię napięcia;"},{"name":"zmiany częstotliwości sieci zasilającej; narażenia EMC pod kątem bezpieczeństwa urządzeń"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nnarażenia przewodzone (przewody zasilające wprowadzane do kabli, pobudzanie impulsowe, tłumiona fala sinusoidalna)\nnarażenia promieniowe (pole magnetyczne, pole elektryczne)\nwyładowania elektrostatyczne;\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej; narażenia EMC pod kątem bezpieczeństwa urządzeń","reference":"PN-EN 55035:2017-09 | PN-EN 55035:2017-09/A11:2020-09","norm_bases":["PN-EN 55035:2017-09","PN-EN 55035:2017-09/A11:2020-09"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia multimedialne Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nnarażenia przewodzone (przewody zasilające wprowadzane do kabli, pobudzanie impulsowe, tłumiona fala sinusoidalna)\nnarażenia promieniowe (pole magnetyczne, pole elektryczne)\nwyładowania elektrostatyczne;\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej; narażenia EMC pod kątem bezpieczeństwa urządzeń PN-EN 55035:2017-09 | PN-EN 55035:2017-09/A11:2020-09 Urzadzenia multimedialne Odpornosc na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o czestotliwosci radiowej;\nnarazenia przewodzone (przewody zasilajace wprowadzane do kabli, pobudzanie impulsowe, tlumiona fala sinusoidalna)\nnarazenia promieniowe (pole magnetyczne, pole elektryczne)\nwyladowania elektrostatyczne;\nserie szybkich elektrycznych stanow przejsciowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napiecia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnalami sieciowymi w przylaczu zasilajacym pradu przemiennego;\nwahania napiecia;\nasymetrie napiecia;\nzmiany czestotliwosci sieci zasilajacej; narazenia EMC pod katem bezpieczenstwa urzadzen PN-EN 55035:2017-09 | PN-EN 55035:2017-09/A11:2020-09","categories":["electronics"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to:","parameters_en":[{"name":"radiated electromagnetic field;"},{"name":"conducted disturbances induced by radio-frequency fields;"},{"name":"conducted tests (supply conductors introduced into cables, pulse excitation, damped oscillatory wave)"},{"name":"radiated tests (magnetic field, electric field)"},{"name":"electrostatic discharges;"},{"name":"electrical fast transient/burst","range":"do 63 A;"},{"name":"electrical surges","range":"do 63 A;"},{"name":"50 Hz magnetic field;"},{"name":"pulse magnetic field;"},{"name":"voltage dips and interruptions AC and DC","range":"do 32 A;"},{"name":"harmonics and interharmonics including mains signalling at a.c. power port;"},{"name":"voltage fluctuations;"},{"name":"voltage unbalance;"},{"name":"power supply frequency variations; EMC immunity with regard to equipment safety"}],"search_en":"Multimedia equipment Resistance to: radiated electromagnetic field; conducted disturbances induced by radio-frequency fields; conducted tests (supply conductors introduced into cables, pulse excitation, damped oscillatory wave) radiated tests (magnetic field, electric field) electrostatic discharges; electrical fast transient/burst electrical surges 50 Hz magnetic field; pulse magnetic field; voltage dips and interruptions AC and DC harmonics and interharmonics including mains signalling at a.c. power port; voltage fluctuations; voltage unbalance; power supply frequency variations; EMC immunity with regard to equipment safety PN-EN 55035:2017-09 | PN-EN 55035:2017-09/A11:2020-09","test_object_en":"Multimedia equipment","methodology_zh":"耐受性：","search_zh":"多媒体设备 耐受性： 辐射电磁场； 射频场感应的传导骚扰； 传导抗扰度（引入电缆的馈电导线、脉冲激励、阻尼正弦波） 辐射抗扰度（磁场、电场） 静电放电； 电快速瞬变脉冲群 浪涌（冲击） 50 Hz 工频磁场； 脉冲磁场； 交流与直流电压暂降与短时中断 交流供电接入点的谐波、间谐波及电网信号； 电压波动； 电压不平衡； 供电网频率变化；设备安全性方面的电磁兼容抗扰度 PN-EN 55035:2017-09 | PN-EN 55035:2017-09/A11:2020-09","parameters_zh":[{"name":"辐射电磁场；"},{"name":"射频场感应的传导骚扰；"},{"name":"传导抗扰度（引入电缆的馈电导线、脉冲激励、阻尼正弦波）"},{"name":"辐射抗扰度（磁场、电场）"},{"name":"静电放电；"},{"name":"电快速瞬变脉冲群","range":"do 63 A;"},{"name":"浪涌（冲击）","range":"do 63 A;"},{"name":"50 Hz 工频磁场；"},{"name":"脉冲磁场；"},{"name":"交流与直流电压暂降与短时中断","range":"do 32 A;"},{"name":"交流供电接入点的谐波、间谐波及电网信号；"},{"name":"电压波动；"},{"name":"电压不平衡；"},{"name":"供电网频率变化；设备安全性方面的电磁兼容抗扰度"}],"test_object_zh":"多媒体设备"},{"_id":"6a82ef00884ede9a1b2c4ba8","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Urządzenia systemów alarmowych pożarowych, włamaniowych","methodology":"Odporność na:","parameters":[{"name":"promieniowane pole elektromagnetyczne;"},{"name":"zaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;"},{"name":"wyładowania elektrostatyczne;"},{"name":"serie szybkich elektrycznych stanów przejściowych","range":"do 63 A;"},{"name":"udary elektryczne","range":"do 63 A;"},{"name":"pole magnetyczne 50 Hz;"},{"name":"impulsowe pole magnetyczne;"},{"name":"zapady i zaniki napięcia AC i DC","range":"do 32 A;"},{"name":"harmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;"},{"name":"wahania napięcia;"},{"name":"asymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz","range":"do 150 kHz;"},{"name":"asymetrię napięcia;"},{"name":"zmiany częstotliwości sieci zasilającej;"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nwyładowania elektrostatyczne;\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz do 150 kHz;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej;","reference":"PN-EN 50130-4:2012 | PN-EN 50130-4:2012/A1:2015-03","norm_bases":["PN-EN 50130-4:2012","PN-EN 50130-4:2012/A1:2015-03"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia systemów alarmowych pożarowych, włamaniowych Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nwyładowania elektrostatyczne;\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz do 150 kHz;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej; PN-EN 50130-4:2012 | PN-EN 50130-4:2012/A1:2015-03 Urzadzenia systemow alarmowych pozarowych, wlamaniowych Odpornosc na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o czestotliwosci radiowej;\nwyladowania elektrostatyczne;\nserie szybkich elektrycznych stanow przejsciowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napiecia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnalami sieciowymi w przylaczu zasilajacym pradu przemiennego;\nwahania napiecia;\nasymetryczne zaburzenia przewodzone, w zakresie czestotliwosci od 0 Hz do 150 kHz;\nasymetrie napiecia;\nzmiany czestotliwosci sieci zasilajacej; PN-EN 50130-4:2012 | PN-EN 50130-4:2012/A1:2015-03","categories":["other"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to:","parameters_en":[{"name":"radiated electromagnetic field;"},{"name":"conducted disturbances induced by radio-frequency fields;"},{"name":"electrostatic discharges;"},{"name":"electrical fast transient/burst","range":"do 63 A;"},{"name":"electrical surges","range":"do 63 A;"},{"name":"50 Hz magnetic field;"},{"name":"pulse magnetic field;"},{"name":"voltage dips and interruptions AC and DC","range":"do 32 A;"},{"name":"harmonics and interharmonics including mains signalling at a.c. power port;"},{"name":"voltage fluctuations;"},{"name":"asymmetric conducted disturbances, in the frequency range from 0 Hz","range":"do 150 kHz;"},{"name":"voltage unbalance;"},{"name":"changes of the power supply frequency;"}],"search_en":"Equipment of fire and intruder alarm systems Resistance to: radiated electromagnetic field; conducted disturbances induced by radio-frequency fields; electrostatic discharges; electrical fast transient/burst electrical surges 50 Hz magnetic field; pulse magnetic field; voltage dips and interruptions AC and DC harmonics and interharmonics including mains signalling at a.c. power port; voltage fluctuations; asymmetric conducted disturbances, in the frequency range from 0 Hz voltage unbalance; changes of the power supply frequency; PN-EN 50130-4:2012 | PN-EN 50130-4:2012/A1:2015-03","test_object_en":"Equipment of fire and intruder alarm systems","methodology_zh":"耐受性：","search_zh":"耐受性： 辐射电磁场； 射频场感应的传导骚扰； 静电放电； 电快速瞬变脉冲群 浪涌（冲击） 50 Hz 工频磁场； 脉冲磁场； 交流与直流电压暂降与短时中断 交流供电接入点的谐波、间谐波及电网信号； 电压波动； 不对称传导骚扰，频率范围自 0 Hz 起 电压不平衡； 供电网频率变化； PN-EN 50130-4:2012 | PN-EN 50130-4:2012/A1:2015-03","parameters_zh":[{"name":"辐射电磁场；"},{"name":"射频场感应的传导骚扰；"},{"name":"静电放电；"},{"name":"电快速瞬变脉冲群","range":"do 63 A;"},{"name":"浪涌（冲击）","range":"do 63 A;"},{"name":"50 Hz 工频磁场；"},{"name":"脉冲磁场；"},{"name":"交流与直流电压暂降与短时中断","range":"do 32 A;"},{"name":"交流供电接入点的谐波、间谐波及电网信号；"},{"name":"电压波动；"},{"name":"不对称传导骚扰，频率范围自 0 Hz 起","range":"do 150 kHz;"},{"name":"电压不平衡；"},{"name":"供电网频率变化；"}]},{"_id":"6a82ef00884ede9a1b2c4ba9","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Automatyczne regulatory elektryczne do użytku domowego i podobnego","methodology":"Odporność na:","parameters":[{"name":"promieniowane pole elektromagnetyczne;"},{"name":"zaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;"},{"name":"wyładowania elektrostatyczne;"},{"name":"serie szybkich elektrycznych stanów przejściowych","range":"do 63 A;"},{"name":"udary elektryczne","range":"do 63 A;"},{"name":"pole magnetyczne 50 Hz;"},{"name":"impulsowe pole magnetyczne;"},{"name":"zapady i zaniki napięcia AC i DC","range":"do 32 A;"},{"name":"harmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;"},{"name":"wahania napięcia;"},{"name":"asymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz","range":"do 150 kHz;"},{"name":"asymetrię napięcia;"},{"name":"zmiany częstotliwości sieci zasilającej;"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nwyładowania elektrostatyczne;\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz do 150 kHz;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej;","reference":"PN-EN 60730-1:2016-10 | PN-EN 60730-1:2016-10/A1:2019-07","norm_bases":["PN-EN 60730-1:2016-10","PN-EN 60730-1:2016-10/A1:2019-07"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne regulatory elektryczne do użytku domowego i podobnego Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nwyładowania elektrostatyczne;\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz do 150 kHz;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej; PN-EN 60730-1:2016-10 | PN-EN 60730-1:2016-10/A1:2019-07 Automatyczne regulatory elektryczne do uzytku domowego i podobnego Odpornosc na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o czestotliwosci radiowej;\nwyladowania elektrostatyczne;\nserie szybkich elektrycznych stanow przejsciowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napiecia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnalami sieciowymi w przylaczu zasilajacym pradu przemiennego;\nwahania napiecia;\nasymetryczne zaburzenia przewodzone, w zakresie czestotliwosci od 0 Hz do 150 kHz;\nasymetrie napiecia;\nzmiany czestotliwosci sieci zasilajacej; PN-EN 60730-1:2016-10 | PN-EN 60730-1:2016-10/A1:2019-07","categories":["other"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to:","parameters_en":[{"name":"radiated electromagnetic field;"},{"name":"conducted disturbances induced by radio-frequency fields;"},{"name":"electrostatic discharges;"},{"name":"electrical fast transient/burst","range":"do 63 A;"},{"name":"electrical surges","range":"do 63 A;"},{"name":"50 Hz magnetic field;"},{"name":"pulse magnetic field;"},{"name":"voltage dips and interruptions AC and DC","range":"do 32 A;"},{"name":"harmonics and interharmonics including mains signalling at a.c. power port;"},{"name":"voltage fluctuations;"},{"name":"asymmetric conducted disturbances, in the frequency range from 0 Hz","range":"do 150 kHz;"},{"name":"voltage unbalance;"},{"name":"changes of the power supply frequency;"}],"search_en":"Automatic electrical controls for household and similar use Resistance to: radiated electromagnetic field; conducted disturbances induced by radio-frequency fields; electrostatic discharges; electrical fast transient/burst electrical surges 50 Hz magnetic field; pulse magnetic field; voltage dips and interruptions AC and DC harmonics and interharmonics including mains signalling at a.c. power port; voltage fluctuations; asymmetric conducted disturbances, in the frequency range from 0 Hz voltage unbalance; changes of the power supply frequency; PN-EN 60730-1:2016-10 | PN-EN 60730-1:2016-10/A1:2019-07","test_object_en":"Automatic electrical controls for household and similar use","methodology_zh":"耐受性：","search_zh":"耐受性： 辐射电磁场； 射频场感应的传导骚扰； 静电放电； 电快速瞬变脉冲群 浪涌（冲击） 50 Hz 工频磁场； 脉冲磁场； 交流与直流电压暂降与短时中断 交流供电接入点的谐波、间谐波及电网信号； 电压波动； 不对称传导骚扰，频率范围自 0 Hz 起 电压不平衡； 供电网频率变化； PN-EN 60730-1:2016-10 | PN-EN 60730-1:2016-10/A1:2019-07","parameters_zh":[{"name":"辐射电磁场；"},{"name":"射频场感应的传导骚扰；"},{"name":"静电放电；"},{"name":"电快速瞬变脉冲群","range":"do 63 A;"},{"name":"浪涌（冲击）","range":"do 63 A;"},{"name":"50 Hz 工频磁场；"},{"name":"脉冲磁场；"},{"name":"交流与直流电压暂降与短时中断","range":"do 32 A;"},{"name":"交流供电接入点的谐波、间谐波及电网信号；"},{"name":"电压波动；"},{"name":"不对称传导骚扰，频率范围自 0 Hz 起","range":"do 150 kHz;"},{"name":"电压不平衡；"},{"name":"供电网频率变化；"}]},{"_id":"6a82ef00884ede9a1b2c4baa","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Środowisko kolejowe. Aparatura instalowana na pojazdach kolejowych, tramwajowych, metrze i trolejbusach. Aparatura sterowania ruchem. Aparatura telekomunikacyjna. Aparatura energetyczna","methodology":"Odporność na:","parameters":[{"name":"promieniowane pole elektromagnetyczne;"},{"name":"zaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;"},{"name":"wyładowania elektrostatyczne;"},{"name":"serie szybkich elektrycznych stanów przejściowych","range":"do 63 A;"},{"name":"udary elektryczne","range":"do 63 A;"},{"name":"pole magnetyczne 50 Hz;"},{"name":"impulsowe pole magnetyczne;"},{"name":"zapady i zaniki napięcia AC i DC","range":"do 32 A;"},{"name":"harmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;"},{"name":"wahania napięcia;"},{"name":"asymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz","range":"do 150 kHz;"},{"name":"asymetrię napięcia;"},{"name":"zmiany częstotliwości sieci zasilającej;"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nwyładowania elektrostatyczne;\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz do 150 kHz;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej;","reference":"PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 | PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","norm_bases":["PN-EN 50121-3-2:2017-04","PN-EN 50121-3-2:2017-04/A1:2019-07","PN-EN 50121-4:2017-04","PN-EN 50121-4:2017-04/A1:2019-07","PN-EN 50121-5:2017-05","PN-EN 50121-5:2017-05/A1:2019-07"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko kolejowe. Aparatura instalowana na pojazdach kolejowych, tramwajowych, metrze i trolejbusach. Aparatura sterowania ruchem. Aparatura telekomunikacyjna. Aparatura energetyczna Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nwyładowania elektrostatyczne;\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz do 150 kHz;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej; PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 | PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07 Srodowisko kolejowe. Aparatura instalowana na pojazdach kolejowych, tramwajowych, metrze i trolejbusach. Aparatura sterowania ruchem. Aparatura telekomunikacyjna. Aparatura energetyczna Odpornosc na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o czestotliwosci radiowej;\nwyladowania elektrostatyczne;\nserie szybkich elektrycznych stanow przejsciowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napiecia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnalami sieciowymi w przylaczu zasilajacym pradu przemiennego;\nwahania napiecia;\nasymetryczne zaburzenia przewodzone, w zakresie czestotliwosci od 0 Hz do 150 kHz;\nasymetrie napiecia;\nzmiany czestotliwosci sieci zasilajacej; PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 | PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","categories":["environment","automotive"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to:","parameters_en":[{"name":"radiated electromagnetic field;"},{"name":"conducted disturbances induced by radio-frequency fields;"},{"name":"electrostatic discharges;"},{"name":"electrical fast transient/burst","range":"do 63 A;"},{"name":"electrical surges","range":"do 63 A;"},{"name":"50 Hz magnetic field;"},{"name":"pulse magnetic field;"},{"name":"voltage dips and interruptions AC and DC","range":"do 32 A;"},{"name":"harmonics and interharmonics including mains signalling at a.c. power port;"},{"name":"voltage fluctuations;"},{"name":"asymmetric conducted disturbances, in the frequency range from 0 Hz","range":"do 150 kHz;"},{"name":"voltage unbalance;"},{"name":"changes of the power supply frequency;"}],"search_en":"Railway environment. Apparatus installed on railway vehicles, trams, metro and trolleybuses. Signalling apparatus. Telecommunications apparatus. Power apparatus Resistance to: radiated electromagnetic field; conducted disturbances induced by radio-frequency fields; electrostatic discharges; electrical fast transient/burst electrical surges 50 Hz magnetic field; pulse magnetic field; voltage dips and interruptions AC and DC harmonics and interharmonics including mains signalling at a.c. power port; voltage fluctuations; asymmetric conducted disturbances, in the frequency range from 0 Hz voltage unbalance; changes of the power supply frequency; PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 | PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","test_object_en":"Railway environment. Apparatus installed on railway vehicles, trams, metro and trolleybuses. Signalling apparatus. Telecommunications apparatus. Power apparatus","methodology_zh":"耐受性：","search_zh":"耐受性： 辐射电磁场； 射频场感应的传导骚扰； 静电放电； 电快速瞬变脉冲群 浪涌（冲击） 50 Hz 工频磁场； 脉冲磁场； 交流与直流电压暂降与短时中断 交流供电接入点的谐波、间谐波及电网信号； 电压波动； 不对称传导骚扰，频率范围自 0 Hz 起 电压不平衡； 供电网频率变化； PN-EN 50121-3-2:2017-04 | PN-EN 50121-3-2:2017-04/A1:2019-07 | PN-EN 50121-4:2017-04 | PN-EN 50121-4:2017-04/A1:2019-07 | PN-EN 50121-5:2017-05 | PN-EN 50121-5:2017-05/A1:2019-07","parameters_zh":[{"name":"辐射电磁场；"},{"name":"射频场感应的传导骚扰；"},{"name":"静电放电；"},{"name":"电快速瞬变脉冲群","range":"do 63 A;"},{"name":"浪涌（冲击）","range":"do 63 A;"},{"name":"50 Hz 工频磁场；"},{"name":"脉冲磁场；"},{"name":"交流与直流电压暂降与短时中断","range":"do 32 A;"},{"name":"交流供电接入点的谐波、间谐波及电网信号；"},{"name":"电压波动；"},{"name":"不对称传导骚扰，频率范围自 0 Hz 起","range":"do 150 kHz;"},{"name":"电压不平衡；"},{"name":"供电网频率变化；"}]},{"_id":"6a82ef00884ede9a1b2c4bab","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Wyposażenie elektryczne do pomiarów, sterowania i użytku w laboratoriach","methodology":"Odporność na:","parameters":[{"name":"promieniowane pole elektromagnetyczne;"},{"name":"zaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;"},{"name":"wyładowania elektrostatyczne;"},{"name":"serie szybkich elektrycznych stanów przejściowych","range":"do 63 A;"},{"name":"udary elektryczne","range":"do 63 A;"},{"name":"pole magnetyczne 50 Hz;"},{"name":"impulsowe pole magnetyczne;"},{"name":"zapady i zaniki napięcia AC i DC","range":"do 32 A;"},{"name":"harmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;"},{"name":"wahania napięcia;"},{"name":"asymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz","range":"do 150 kHz;"},{"name":"asymetrię napięcia;"},{"name":"zmiany częstotliwości sieci zasilającej; narażenia EMC pod kątem bezpieczeństwa urządzeń"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nwyładowania elektrostatyczne;\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz do 150 kHz;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej; narażenia EMC pod kątem bezpieczeństwa urządzeń","reference":"PN-EN 61326-1:2013-06 | PN-EN 61326-1:2021-10 | PN-EN 61326-2-2:2013-07 | PN-EN 61326-2-2:2021-11","norm_bases":["PN-EN 61326-1:2013-06","PN-EN 61326-1:2021-10","PN-EN 61326-2-2:2013-07","PN-EN 61326-2-2:2021-11"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyposażenie elektryczne do pomiarów, sterowania i użytku w laboratoriach Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nwyładowania elektrostatyczne;\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz do 150 kHz;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej; narażenia EMC pod kątem bezpieczeństwa urządzeń PN-EN 61326-1:2013-06 | PN-EN 61326-1:2021-10 | PN-EN 61326-2-2:2013-07 | PN-EN 61326-2-2:2021-11 Wyposazenie elektryczne do pomiarow, sterowania i uzytku w laboratoriach Odpornosc na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o czestotliwosci radiowej;\nwyladowania elektrostatyczne;\nserie szybkich elektrycznych stanow przejsciowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napiecia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnalami sieciowymi w przylaczu zasilajacym pradu przemiennego;\nwahania napiecia;\nasymetryczne zaburzenia przewodzone, w zakresie czestotliwosci od 0 Hz do 150 kHz;\nasymetrie napiecia;\nzmiany czestotliwosci sieci zasilajacej; narazenia EMC pod katem bezpieczenstwa urzadzen PN-EN 61326-1:2013-06 | PN-EN 61326-1:2021-10 | PN-EN 61326-2-2:2013-07 | PN-EN 61326-2-2:2021-11","categories":["electronics"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to:","parameters_en":[{"name":"radiated electromagnetic field;"},{"name":"conducted disturbances induced by radio-frequency fields;"},{"name":"electrostatic discharges;"},{"name":"electrical fast transient/burst","range":"do 63 A;"},{"name":"electrical surges","range":"do 63 A;"},{"name":"50 Hz magnetic field;"},{"name":"pulse magnetic field;"},{"name":"voltage dips and interruptions AC and DC","range":"do 32 A;"},{"name":"harmonics and interharmonics including mains signalling at a.c. power port;"},{"name":"voltage fluctuations;"},{"name":"asymmetric conducted disturbances, in the frequency range from 0 Hz","range":"do 150 kHz;"},{"name":"voltage unbalance;"},{"name":"power supply frequency variations; EMC immunity with regard to equipment safety"}],"search_en":"Electrical equipment for measurement, control and laboratory use Resistance to: radiated electromagnetic field; conducted disturbances induced by radio-frequency fields; electrostatic discharges; electrical fast transient/burst electrical surges 50 Hz magnetic field; pulse magnetic field; voltage dips and interruptions AC and DC harmonics and interharmonics including mains signalling at a.c. power port; voltage fluctuations; asymmetric conducted disturbances, in the frequency range from 0 Hz voltage unbalance; power supply frequency variations; EMC immunity with regard to equipment safety PN-EN 61326-1:2013-06 | PN-EN 61326-1:2021-10 | PN-EN 61326-2-2:2013-07 | PN-EN 61326-2-2:2021-11","test_object_en":"Electrical equipment for measurement, control and laboratory use","methodology_zh":"耐受性：","search_zh":"测量、控制与实验室用电气设备 耐受性： 辐射电磁场； 射频场感应的传导骚扰； 静电放电； 电快速瞬变脉冲群 浪涌（冲击） 50 Hz 工频磁场； 脉冲磁场； 交流与直流电压暂降与短时中断 交流供电接入点的谐波、间谐波及电网信号； 电压波动； 不对称传导骚扰，频率范围自 0 Hz 起 电压不平衡； 供电网频率变化；设备安全性方面的电磁兼容抗扰度 PN-EN 61326-1:2013-06 | PN-EN 61326-1:2021-10 | PN-EN 61326-2-2:2013-07 | PN-EN 61326-2-2:2021-11","parameters_zh":[{"name":"辐射电磁场；"},{"name":"射频场感应的传导骚扰；"},{"name":"静电放电；"},{"name":"电快速瞬变脉冲群","range":"do 63 A;"},{"name":"浪涌（冲击）","range":"do 63 A;"},{"name":"50 Hz 工频磁场；"},{"name":"脉冲磁场；"},{"name":"交流与直流电压暂降与短时中断","range":"do 32 A;"},{"name":"交流供电接入点的谐波、间谐波及电网信号；"},{"name":"电压波动；"},{"name":"不对称传导骚扰，频率范围自 0 Hz 起","range":"do 150 kHz;"},{"name":"电压不平衡；"},{"name":"供电网频率变化；设备安全性方面的电磁兼容抗扰度"}],"test_object_zh":"测量、控制与实验室用电气设备"},{"_id":"6a82ef00884ede9a1b2c4bac","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Przekaźniki czasowe do zastosowań przemysłowych i mieszkaniowych","methodology":"Odporność na:","parameters":[{"name":"promieniowane pole elektromagnetyczne;"},{"name":"zaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;"},{"name":"wyładowania elektrostatyczne;"},{"name":"serie szybkich elektrycznych stanów przejściowych","range":"do 63 A;"},{"name":"udary elektryczne","range":"do 63 A;"},{"name":"pole magnetyczne 50 Hz;"},{"name":"impulsowe pole magnetyczne;"},{"name":"zapady i zaniki napięcia AC i DC","range":"do 32 A;"},{"name":"harmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;"},{"name":"wahania napięcia;"},{"name":"asymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz","range":"do 150 kHz;"},{"name":"asymetrię napięcia;"},{"name":"zmiany częstotliwości sieci zasilającej; narażenia EMC pod kątem bezpieczeństwa urządzeń"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nwyładowania elektrostatyczne;\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz do 150 kHz;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej; narażenia EMC pod kątem bezpieczeństwa urządzeń","reference":"PN-EN 61812-1:2011","norm_bases":["PN-EN 61812-1:2011"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przekaźniki czasowe do zastosowań przemysłowych i mieszkaniowych Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nwyładowania elektrostatyczne;\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz do 150 kHz;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej; narażenia EMC pod kątem bezpieczeństwa urządzeń PN-EN 61812-1:2011 Przekazniki czasowe do zastosowan przemyslowych i mieszkaniowych Odpornosc na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o czestotliwosci radiowej;\nwyladowania elektrostatyczne;\nserie szybkich elektrycznych stanow przejsciowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napiecia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnalami sieciowymi w przylaczu zasilajacym pradu przemiennego;\nwahania napiecia;\nasymetryczne zaburzenia przewodzone, w zakresie czestotliwosci od 0 Hz do 150 kHz;\nasymetrie napiecia;\nzmiany czestotliwosci sieci zasilajacej; narazenia EMC pod katem bezpieczenstwa urzadzen PN-EN 61812-1:2011","categories":["electronics"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to:","parameters_en":[{"name":"radiated electromagnetic field;"},{"name":"conducted disturbances induced by radio-frequency fields;"},{"name":"electrostatic discharges;"},{"name":"electrical fast transient/burst","range":"do 63 A;"},{"name":"electrical surges","range":"do 63 A;"},{"name":"50 Hz magnetic field;"},{"name":"pulse magnetic field;"},{"name":"voltage dips and interruptions AC and DC","range":"do 32 A;"},{"name":"harmonics and interharmonics including mains signalling at a.c. power port;"},{"name":"voltage fluctuations;"},{"name":"asymmetric conducted disturbances, in the frequency range from 0 Hz","range":"do 150 kHz;"},{"name":"voltage unbalance;"},{"name":"power supply frequency variations; EMC immunity with regard to equipment safety"}],"search_en":"Time relays for industrial and residential applications Resistance to: radiated electromagnetic field; conducted disturbances induced by radio-frequency fields; electrostatic discharges; electrical fast transient/burst electrical surges 50 Hz magnetic field; pulse magnetic field; voltage dips and interruptions AC and DC harmonics and interharmonics including mains signalling at a.c. power port; voltage fluctuations; asymmetric conducted disturbances, in the frequency range from 0 Hz voltage unbalance; power supply frequency variations; EMC immunity with regard to equipment safety PN-EN 61812-1:2011","test_object_en":"Time relays for industrial and residential applications","methodology_zh":"耐受性：","search_zh":"耐受性： 辐射电磁场； 射频场感应的传导骚扰； 静电放电； 电快速瞬变脉冲群 浪涌（冲击） 50 Hz 工频磁场； 脉冲磁场； 交流与直流电压暂降与短时中断 交流供电接入点的谐波、间谐波及电网信号； 电压波动； 不对称传导骚扰，频率范围自 0 Hz 起 电压不平衡； 供电网频率变化；设备安全性方面的电磁兼容抗扰度 PN-EN 61812-1:2011","parameters_zh":[{"name":"辐射电磁场；"},{"name":"射频场感应的传导骚扰；"},{"name":"静电放电；"},{"name":"电快速瞬变脉冲群","range":"do 63 A;"},{"name":"浪涌（冲击）","range":"do 63 A;"},{"name":"50 Hz 工频磁场；"},{"name":"脉冲磁场；"},{"name":"交流与直流电压暂降与短时中断","range":"do 32 A;"},{"name":"交流供电接入点的谐波、间谐波及电网信号；"},{"name":"电压波动；"},{"name":"不对称传导骚扰，频率范围自 0 Hz 起","range":"do 150 kHz;"},{"name":"电压不平衡；"},{"name":"供电网频率变化；设备安全性方面的电磁兼容抗扰度"}]},{"_id":"6a82ef00884ede9a1b2c4bad","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Systemy bezprzerwowego zasilania (UPS)","methodology":"Odporność na:","parameters":[{"name":"promieniowane pole elektromagnetyczne;"},{"name":"zaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;"},{"name":"wyładowania elektrostatyczne;"},{"name":"serie szybkich elektrycznych stanów przejściowych","range":"do 63 A;"},{"name":"udary elektryczne","range":"do 63 A;"},{"name":"pole magnetyczne 50 Hz;"},{"name":"impulsowe pole magnetyczne;"},{"name":"zapady i zaniki napięcia AC i DC","range":"do 32 A;"},{"name":"harmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;"},{"name":"wahania napięcia;"},{"name":"asymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz","range":"do 150 kHz;"},{"name":"asymetrię napięcia;"},{"name":"zmiany częstotliwości sieci zasilającej; narażenia EMC pod kątem bezpieczeństwa urządzeń"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nwyładowania elektrostatyczne;\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz do 150 kHz;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej; narażenia EMC pod kątem bezpieczeństwa urządzeń","reference":"PN-EN 62040-2:2008 | PN-EN 62040-2:2019-02","norm_bases":["PN-EN 62040-2:2008","PN-EN 62040-2:2019-02"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Systemy bezprzerwowego zasilania (UPS) Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nwyładowania elektrostatyczne;\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz do 150 kHz;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej; narażenia EMC pod kątem bezpieczeństwa urządzeń PN-EN 62040-2:2008 | PN-EN 62040-2:2019-02 Systemy bezprzerwowego zasilania (UPS) Odpornosc na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o czestotliwosci radiowej;\nwyladowania elektrostatyczne;\nserie szybkich elektrycznych stanow przejsciowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napiecia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnalami sieciowymi w przylaczu zasilajacym pradu przemiennego;\nwahania napiecia;\nasymetryczne zaburzenia przewodzone, w zakresie czestotliwosci od 0 Hz do 150 kHz;\nasymetrie napiecia;\nzmiany czestotliwosci sieci zasilajacej; narazenia EMC pod katem bezpieczenstwa urzadzen PN-EN 62040-2:2008 | PN-EN 62040-2:2019-02","categories":["electronics"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to:","parameters_en":[{"name":"radiated electromagnetic field;"},{"name":"conducted disturbances induced by radio-frequency fields;"},{"name":"electrostatic discharges;"},{"name":"electrical fast transient/burst","range":"do 63 A;"},{"name":"electrical surges","range":"do 63 A;"},{"name":"50 Hz magnetic field;"},{"name":"pulse magnetic field;"},{"name":"voltage dips and interruptions AC and DC","range":"do 32 A;"},{"name":"harmonics and interharmonics including mains signalling at a.c. power port;"},{"name":"voltage fluctuations;"},{"name":"asymmetric conducted disturbances, in the frequency range from 0 Hz","range":"do 150 kHz;"},{"name":"voltage unbalance;"},{"name":"power supply frequency variations; EMC immunity with regard to equipment safety"}],"search_en":"Uninterruptible power systems (UPS) Resistance to: radiated electromagnetic field; conducted disturbances induced by radio-frequency fields; electrostatic discharges; electrical fast transient/burst electrical surges 50 Hz magnetic field; pulse magnetic field; voltage dips and interruptions AC and DC harmonics and interharmonics including mains signalling at a.c. power port; voltage fluctuations; asymmetric conducted disturbances, in the frequency range from 0 Hz voltage unbalance; power supply frequency variations; EMC immunity with regard to equipment safety PN-EN 62040-2:2008 | PN-EN 62040-2:2019-02","test_object_en":"Uninterruptible power systems (UPS)","methodology_zh":"耐受性：","search_zh":"不间断电源系统（UPS） 耐受性： 辐射电磁场； 射频场感应的传导骚扰； 静电放电； 电快速瞬变脉冲群 浪涌（冲击） 50 Hz 工频磁场； 脉冲磁场； 交流与直流电压暂降与短时中断 交流供电接入点的谐波、间谐波及电网信号； 电压波动； 不对称传导骚扰，频率范围自 0 Hz 起 电压不平衡； 供电网频率变化；设备安全性方面的电磁兼容抗扰度 PN-EN 62040-2:2008 | PN-EN 62040-2:2019-02","parameters_zh":[{"name":"辐射电磁场；"},{"name":"射频场感应的传导骚扰；"},{"name":"静电放电；"},{"name":"电快速瞬变脉冲群","range":"do 63 A;"},{"name":"浪涌（冲击）","range":"do 63 A;"},{"name":"50 Hz 工频磁场；"},{"name":"脉冲磁场；"},{"name":"交流与直流电压暂降与短时中断","range":"do 32 A;"},{"name":"交流供电接入点的谐波、间谐波及电网信号；"},{"name":"电压波动；"},{"name":"不对称传导骚扰，频率范围自 0 Hz 起","range":"do 150 kHz;"},{"name":"电压不平衡；"},{"name":"供电网频率变化；设备安全性方面的电磁兼容抗扰度"}],"test_object_zh":"不间断电源系统（UPS）"},{"_id":"6a82ef00884ede9a1b2c4bae","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Ciepłomierze","methodology":"Odporność na:","parameters":[{"name":"promieniowane pole elektromagnetyczne;"},{"name":"zaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;"},{"name":"wyładowania elektrostatyczne;"},{"name":"serie szybkich elektrycznych stanów przejściowych","range":"do 63 A;"},{"name":"udary elektryczne","range":"do 63 A;"},{"name":"pole magnetyczne 50 Hz;"},{"name":"impulsowe pole magnetyczne;"},{"name":"zapady i zaniki napięcia AC i DC","range":"do 32 A;"},{"name":"harmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;"},{"name":"wahania napięcia;"},{"name":"asymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz","range":"do 150 kHz;"},{"name":"asymetrię napięcia;"},{"name":"zmiany częstotliwości sieci zasilającej;"},{"name":"narażenia EMC pod kątem bezpieczeństwa urządzeń"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nwyładowania elektrostatyczne;\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz do 150 kHz;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej;\nnarażenia EMC pod kątem bezpieczeństwa urządzeń","reference":"PN-EN 1434-4:2016-01","norm_bases":["PN-EN 1434-4:2016-01"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ciepłomierze Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nwyładowania elektrostatyczne;\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz do 150 kHz;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej;\nnarażenia EMC pod kątem bezpieczeństwa urządzeń PN-EN 1434-4:2016-01 Cieplomierze Odpornosc na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o czestotliwosci radiowej;\nwyladowania elektrostatyczne;\nserie szybkich elektrycznych stanow przejsciowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napiecia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnalami sieciowymi w przylaczu zasilajacym pradu przemiennego;\nwahania napiecia;\nasymetryczne zaburzenia przewodzone, w zakresie czestotliwosci od 0 Hz do 150 kHz;\nasymetrie napiecia;\nzmiany czestotliwosci sieci zasilajacej;\nnarazenia EMC pod katem bezpieczenstwa urzadzen PN-EN 1434-4:2016-01","categories":["electronics"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to:","parameters_en":[{"name":"radiated electromagnetic field;"},{"name":"conducted disturbances induced by radio-frequency fields;"},{"name":"electrostatic discharges;"},{"name":"electrical fast transient/burst","range":"do 63 A;"},{"name":"electrical surges","range":"do 63 A;"},{"name":"50 Hz magnetic field;"},{"name":"pulse magnetic field;"},{"name":"voltage dips and interruptions AC and DC","range":"do 32 A;"},{"name":"harmonics and interharmonics including mains signalling at a.c. power port;"},{"name":"voltage fluctuations;"},{"name":"asymmetric conducted disturbances, in the frequency range from 0 Hz","range":"do 150 kHz;"},{"name":"voltage unbalance;"},{"name":"changes of the power supply frequency;"},{"name":"EMC immunity tests with regard to equipment safety"}],"search_en":"Heat meters Resistance to: radiated electromagnetic field; conducted disturbances induced by radio-frequency fields; electrostatic discharges; electrical fast transient/burst electrical surges 50 Hz magnetic field; pulse magnetic field; voltage dips and interruptions AC and DC harmonics and interharmonics including mains signalling at a.c. power port; voltage fluctuations; asymmetric conducted disturbances, in the frequency range from 0 Hz voltage unbalance; changes of the power supply frequency; EMC immunity tests with regard to equipment safety PN-EN 1434-4:2016-01","test_object_en":"Heat meters","methodology_zh":"耐受性：","search_zh":"耐受性： 辐射电磁场； 射频场感应的传导骚扰； 静电放电； 电快速瞬变脉冲群 浪涌（冲击） 50 Hz 工频磁场； 脉冲磁场； 交流与直流电压暂降与短时中断 交流供电接入点的谐波、间谐波及电网信号； 电压波动； 不对称传导骚扰，频率范围自 0 Hz 起 电压不平衡； 供电网频率变化； 设备安全性方面的电磁兼容抗扰度 PN-EN 1434-4:2016-01","parameters_zh":[{"name":"辐射电磁场；"},{"name":"射频场感应的传导骚扰；"},{"name":"静电放电；"},{"name":"电快速瞬变脉冲群","range":"do 63 A;"},{"name":"浪涌（冲击）","range":"do 63 A;"},{"name":"50 Hz 工频磁场；"},{"name":"脉冲磁场；"},{"name":"交流与直流电压暂降与短时中断","range":"do 32 A;"},{"name":"交流供电接入点的谐波、间谐波及电网信号；"},{"name":"电压波动；"},{"name":"不对称传导骚扰，频率范围自 0 Hz 起","range":"do 150 kHz;"},{"name":"电压不平衡；"},{"name":"供电网频率变化；"},{"name":"设备安全性方面的电磁兼容抗扰度"}]},{"_id":"6a82ef00884ede9a1b2c4baf","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Urządzenia sieci telekomunikacyjnej. Urządzenia komutacyjne. Urządzenia transmisyjne. Zasilacze zewnętrzne do telefonów ruchomych współpracujących z cyfrowym, ruchomym i przenośnym terminalem radiokomunikacyjnym sieci komórkowej wyposażone we wtyk typu USB zdefiniowany w dokumencie M/455","methodology":"Odporność na:","parameters":[{"name":"promieniowane pole elektromagnetyczne;"},{"name":"zaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;"},{"name":"wyładowania elektrostatyczne;"},{"name":"serie szybkich elektrycznych stanów przejściowych","range":"do 63 A;"},{"name":"udary elektryczne","range":"do 63 A;"},{"name":"pole magnetyczne 50 Hz;"},{"name":"impulsowe pole magnetyczne;"},{"name":"zapady i zaniki napięcia AC i DC","range":"do 32 A;"},{"name":"harmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;"},{"name":"wahania napięcia;"},{"name":"asymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz","range":"do 150 kHz;"},{"name":"asymetrię napięcia;"},{"name":"zmiany częstotliwości sieci zasilającej;"},{"name":"narażenia EMC pod kątem bezpieczeństwa urządzeń"}],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nwyładowania elektrostatyczne;\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz do 150 kHz;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej;\nnarażenia EMC pod kątem bezpieczeństwa urządzeń","reference":"PN-ETSI EN 300 386 V1.4.1:2008 | PN-ETSI EN 300 386 V1.5.1:2011 | PN-ETSI EN 301 489-1 V1.9.2:2012 | PN-ETSI EN 301 489-34 V1.1.1:2011","norm_bases":["PN-ETSI EN 300 386 V1.4.1:2008","PN-ETSI EN 300 386 V1.5.1:2011","PN-ETSI EN 301 489-1 V1.9.2:2012","PN-ETSI EN 301 489-34 V1.1.1:2011"],"lab_section":"Laboratorium Badań Kompatybilności Elektromagnetycznej i Pomiarów Pól Elektromagnetycznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia sieci telekomunikacyjnej. Urządzenia komutacyjne. Urządzenia transmisyjne. Zasilacze zewnętrzne do telefonów ruchomych współpracujących z cyfrowym, ruchomym i przenośnym terminalem radiokomunikacyjnym sieci komórkowej wyposażone we wtyk typu USB zdefiniowany w dokumencie M/455 Odporność na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o częstotliwości radiowej;\nwyładowania elektrostatyczne;\nserie szybkich elektrycznych stanów przejściowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napięcia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnałami sieciowymi w przyłączu zasilającym prądu przemiennego;\nwahania napięcia;\nasymetryczne zaburzenia przewodzone, w zakresie częstotliwości od 0 Hz do 150 kHz;\nasymetrię napięcia;\nzmiany częstotliwości sieci zasilającej;\nnarażenia EMC pod kątem bezpieczeństwa urządzeń PN-ETSI EN 300 386 V1.4.1:2008 | PN-ETSI EN 300 386 V1.5.1:2011 | PN-ETSI EN 301 489-1 V1.9.2:2012 | PN-ETSI EN 301 489-34 V1.1.1:2011 Urzadzenia sieci telekomunikacyjnej. Urzadzenia komutacyjne. Urzadzenia transmisyjne. Zasilacze zewnetrzne do telefonow ruchomych wspolpracujacych z cyfrowym, ruchomym i przenosnym terminalem radiokomunikacyjnym sieci komorkowej wyposazone we wtyk typu USB zdefiniowany w dokumencie M/455 Odpornosc na:\nZakres:\npromieniowane pole elektromagnetyczne;\nzaburzenia przewodzone indukowane przez pola o czestotliwosci radiowej;\nwyladowania elektrostatyczne;\nserie szybkich elektrycznych stanow przejsciowych do 63 A;\nudary elektryczne do 63 A;\npole magnetyczne 50 Hz;\nimpulsowe pole magnetyczne;\nzapady i zaniki napiecia AC i DC do 32 A;\nharmoniczne i interharmoniczne wraz z sygnalami sieciowymi w przylaczu zasilajacym pradu przemiennego;\nwahania napiecia;\nasymetryczne zaburzenia przewodzone, w zakresie czestotliwosci od 0 Hz do 150 kHz;\nasymetrie napiecia;\nzmiany czestotliwosci sieci zasilajacej;\nnarazenia EMC pod katem bezpieczenstwa urzadzen PN-ETSI EN 300 386 V1.4.1:2008 | PN-ETSI EN 300 386 V1.5.1:2011 | PN-ETSI EN 301 489-1 V1.9.2:2012 | PN-ETSI EN 301 489-34 V1.1.1:2011","categories":["electronics"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to:","parameters_en":[{"name":"radiated electromagnetic field;"},{"name":"conducted disturbances induced by radio-frequency fields;"},{"name":"electrostatic discharges;"},{"name":"electrical fast transient/burst","range":"do 63 A;"},{"name":"electrical surges","range":"do 63 A;"},{"name":"50 Hz magnetic field;"},{"name":"pulse magnetic field;"},{"name":"voltage dips and interruptions AC and DC","range":"do 32 A;"},{"name":"harmonics and interharmonics including mains signalling at a.c. power port;"},{"name":"voltage fluctuations;"},{"name":"asymmetric conducted disturbances, in the frequency range from 0 Hz","range":"do 150 kHz;"},{"name":"voltage unbalance;"},{"name":"changes of the power supply frequency;"},{"name":"EMC immunity tests with regard to equipment safety"}],"search_en":"Telecommunication network equipment. Switching equipment. Transmission equipment. External power supplies for mobile phones working with a digital mobile and portable radiocommunication terminal of a cellular network, fitted with a USB plug as defined in document M/455 Resistance to: radiated electromagnetic field; conducted disturbances induced by radio-frequency fields; electrostatic discharges; electrical fast transient/burst electrical surges 50 Hz magnetic field; pulse magnetic field; voltage dips and interruptions AC and DC harmonics and interharmonics including mains signalling at a.c. power port; voltage fluctuations; asymmetric conducted disturbances, in the frequency range from 0 Hz voltage unbalance; changes of the power supply frequency; EMC immunity tests with regard to equipment safety PN-ETSI EN 300 386 V1.4.1:2008 | PN-ETSI EN 300 386 V1.5.1:2011 | PN-ETSI EN 301 489-1 V1.9.2:2012 | PN-ETSI EN 301 489-34 V1.1.1:2011","test_object_en":"Telecommunication network equipment. Switching equipment. Transmission equipment. External power supplies for mobile phones working with a digital mobile and portable radiocommunication terminal of a cellular network, fitted with a USB plug as defined in document M/455","methodology_zh":"耐受性：","search_zh":"耐受性： 辐射电磁场； 射频场感应的传导骚扰； 静电放电； 电快速瞬变脉冲群 浪涌（冲击） 50 Hz 工频磁场； 脉冲磁场； 交流与直流电压暂降与短时中断 交流供电接入点的谐波、间谐波及电网信号； 电压波动； 不对称传导骚扰，频率范围自 0 Hz 起 电压不平衡； 供电网频率变化； 设备安全性方面的电磁兼容抗扰度 PN-ETSI EN 300 386 V1.4.1:2008 | PN-ETSI EN 300 386 V1.5.1:2011 | PN-ETSI EN 301 489-1 V1.9.2:2012 | PN-ETSI EN 301 489-34 V1.1.1:2011","parameters_zh":[{"name":"辐射电磁场；"},{"name":"射频场感应的传导骚扰；"},{"name":"静电放电；"},{"name":"电快速瞬变脉冲群","range":"do 63 A;"},{"name":"浪涌（冲击）","range":"do 63 A;"},{"name":"50 Hz 工频磁场；"},{"name":"脉冲磁场；"},{"name":"交流与直流电压暂降与短时中断","range":"do 32 A;"},{"name":"交流供电接入点的谐波、间谐波及电网信号；"},{"name":"电压波动；"},{"name":"不对称传导骚扰，频率范围自 0 Hz 起","range":"do 150 kHz;"},{"name":"电压不平衡；"},{"name":"供电网频率变化；"},{"name":"设备安全性方面的电磁兼容抗扰度"}]},{"_id":"6a82ef00884ede9a1b2c4bb0","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Kamery termowizyjne.","methodology":"Funkcja minimalnej rozróżnialnej różnicy temperatur (MRTD): Od 0,002 do 2oC w zakresie częstości przestrzennych od 0,4 do 25 mrad-1","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Funkcja minimalnej rozróżnialnej różnicy temperatur (MRTD): Od 0,002 do 2oC w zakresie częstości przestrzennych od 0,4 do 25 mrad-1","reference":"LBSO.PB.01 Edycja 1 z dnia 15.03.2019 r. | STANAG nr 4349 /Ed.1 z 1995","norm_bases":["LBSO.PB.01 Edycja 1 z dnia 15.03.2019 r.","STANAG nr 4349 /Ed.1 z 1995"],"lab_section":"Laboratorium Badań Systemów Optoelektronicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kamery termowizyjne. Funkcja minimalnej rozróżnialnej różnicy temperatur (MRTD): Od 0,002 do 2oC w zakresie częstości przestrzennych od 0,4 do 25 mrad-1 LBSO.PB.01 Edycja 1 z dnia 15.03.2019 r. | STANAG nr 4349 /Ed.1 z 1995 Kamery termowizyjne. Funkcja minimalnej rozroznialnej roznicy temperatur (MRTD): Od 0,002 do 2oC w zakresie czestosci przestrzennych od 0,4 do 25 mrad-1 LBSO.PB.01 Edycja 1 z dnia 15.03.2019 r. | STANAG nr 4349 /Ed.1 z 1995","categories":["other"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Minimum resolvable temperature difference (MRTD) function: From 0,002 to 2oC in the spatial frequency range from 0,4 to 25 mrad-1","search_en":"Thermal cameras. Minimum resolvable temperature difference (MRTD) function: From 0,002 to 2oC in the spatial frequency range from 0,4 to 25 mrad-1 LBSO.PB.01 Edycja 1 z dnia 15.03.2019 r. | STANAG nr 4349 /Ed.1 z 1995","test_object_en":"Thermal cameras.","search_zh":"热成像相机。 LBSO.PB.01 Edycja 1 z dnia 15.03.2019 r. | STANAG nr 4349 /Ed.1 z 1995","test_object_zh":"热成像相机。"},{"_id":"6a82ef00884ede9a1b2c4bb1","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Kamery termowizyjne.","methodology":"Temperatura równoważna szumom (NETD) w zakresie (10 – 500) mK","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura równoważna szumom (NETD) w zakresie (10 – 500) mK","reference":"LBSO.PB.02 Edycja 1 z dnia 15.03.2019 r.","norm_bases":["LBSO.PB.02 Edycja 1 z dnia 15.03.2019 r."],"lab_section":"Laboratorium Badań Systemów Optoelektronicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kamery termowizyjne. Temperatura równoważna szumom (NETD) w zakresie (10 – 500) mK LBSO.PB.02 Edycja 1 z dnia 15.03.2019 r. Kamery termowizyjne. Temperatura rownowazna szumom (NETD) w zakresie (10 – 500) mK LBSO.PB.02 Edycja 1 z dnia 15.03.2019 r.","categories":["other"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Thermal cameras. LBSO.PB.02 Edycja 1 z dnia 15.03.2019 r.","test_object_en":"Thermal cameras.","search_zh":"热成像相机。 LBSO.PB.02 Edycja 1 z dnia 15.03.2019 r.","test_object_zh":"热成像相机。"},{"_id":"6a82ef00884ede9a1b2c4bb2","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Kamery termowizyjne.","methodology":"Określanie zasięgów wykrycia, rozpoznania i identyfikacji celów dla kamer termowizyjnych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Określanie zasięgów wykrycia, rozpoznania i identyfikacji celów dla kamer termowizyjnych","reference":"LBSO.PB.03 Edycja 1 z dnia 15.03.2019 r. | STANAG nr 4347 /Ed.1 z 1995r","norm_bases":["LBSO.PB.03 Edycja 1 z dnia 15.03.2019 r.","STANAG nr 4347 /Ed.1 z 1995r"],"lab_section":"Laboratorium Badań Systemów Optoelektronicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kamery termowizyjne. Określanie zasięgów wykrycia, rozpoznania i identyfikacji celów dla kamer termowizyjnych LBSO.PB.03 Edycja 1 z dnia 15.03.2019 r. | STANAG nr 4347 /Ed.1 z 1995r Kamery termowizyjne. Okreslanie zasiegow wykrycia, rozpoznania i identyfikacji celow dla kamer termowizyjnych LBSO.PB.03 Edycja 1 z dnia 15.03.2019 r. | STANAG nr 4347 /Ed.1 z 1995r","categories":["other"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Determination of target detection, recognition and identification ranges for thermal imaging cameras","search_en":"Thermal cameras. Determination of target detection, recognition and identification ranges for thermal imaging cameras LBSO.PB.03 Edycja 1 z dnia 15.03.2019 r. | STANAG nr 4347 /Ed.1 z 1995r","test_object_en":"Thermal cameras.","search_zh":"热成像相机。 LBSO.PB.03 Edycja 1 z dnia 15.03.2019 r. | STANAG nr 4347 /Ed.1 z 1995r","test_object_zh":"热成像相机。"},{"_id":"6a82ef00884ede9a1b2c4bb3","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Kamery termowizyjne.","methodology":"Wyznaczanie pola widzenia (FOV) w zakresie kątów (0,5 – 40)°","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wyznaczanie pola widzenia (FOV) w zakresie kątów (0,5 – 40)°","reference":"LBSO.PB.04 Edycja 1 z dnia 15.03.2019 r.","norm_bases":["LBSO.PB.04 Edycja 1 z dnia 15.03.2019 r."],"lab_section":"Laboratorium Badań Systemów Optoelektronicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kamery termowizyjne. Wyznaczanie pola widzenia (FOV) w zakresie kątów (0,5 – 40)° LBSO.PB.04 Edycja 1 z dnia 15.03.2019 r. Kamery termowizyjne. Wyznaczanie pola widzenia (FOV) w zakresie katow (0,5 – 40)° LBSO.PB.04 Edycja 1 z dnia 15.03.2019 r.","categories":["other"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Thermal cameras. LBSO.PB.04 Edycja 1 z dnia 15.03.2019 r.","test_object_en":"Thermal cameras.","search_zh":"热成像相机。 LBSO.PB.04 Edycja 1 z dnia 15.03.2019 r.","test_object_zh":"热成像相机。"},{"_id":"6a82ef00884ede9a1b2c4bb4","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Kamery TV i LLLTVe","methodology":"Funkcja minimalnego rozróżnialnego kontrastu (MRC) w zakresie ( 0,5 – 456,1 ) lp/mrad","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Funkcja minimalnego rozróżnialnego kontrastu (MRC) w zakresie ( 0,5 – 456,1 ) lp/mrad","reference":"LBSO.PB.05 Edycja 1 z dnia 15.03.2019 r.","norm_bases":["LBSO.PB.05 Edycja 1 z dnia 15.03.2019 r."],"lab_section":"Laboratorium Badań Systemów Optoelektronicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kamery TV i LLLTVe Funkcja minimalnego rozróżnialnego kontrastu (MRC) w zakresie ( 0,5 – 456,1 ) lp/mrad LBSO.PB.05 Edycja 1 z dnia 15.03.2019 r. Kamery TV i LLLTVe Funkcja minimalnego rozroznialnego kontrastu (MRC) w zakresie ( 0,5 – 456,1 ) lp/mrad LBSO.PB.05 Edycja 1 z dnia 15.03.2019 r.","categories":["other"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","search_en":"TV and LLLTVe cameras LBSO.PB.05 Edycja 1 z dnia 15.03.2019 r.","test_object_en":"TV and LLLTVe cameras","search_zh":"电视摄像机与微光电视（LLLTV）摄像机 LBSO.PB.05 Edycja 1 z dnia 15.03.2019 r.","test_object_zh":"电视摄像机与微光电视（LLLTV）摄像机"},{"_id":"6a82ef00884ede9a1b2c4bb5","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Kamery TV i LLLTVe","methodology":"Określanie zasięgów wykrycia rozpoznania i identyfikacji celów","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Określanie zasięgów wykrycia rozpoznania i identyfikacji celów","reference":"LBSO.PB.06 Edycja 1 z dnia 15.03.2019 r. (zgodnie z metodyką zawartą w załączniku A, wycofanego porozumienia standaryzacyjnego STANAG 4347/1988 (nie wprowadzono aktualizacji)","norm_bases":["LBSO.PB.06 Edycja 1 z dnia 15.03.2019 r. (zgodnie z metodyką zawartą w załączniku A, wycofanego porozumienia standaryzacyjnego STANAG 4347/1988 (nie wprowadzono aktualizacji)"],"lab_section":"Laboratorium Badań Systemów Optoelektronicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kamery TV i LLLTVe Określanie zasięgów wykrycia rozpoznania i identyfikacji celów LBSO.PB.06 Edycja 1 z dnia 15.03.2019 r. (zgodnie z metodyką zawartą w załączniku A, wycofanego porozumienia standaryzacyjnego STANAG 4347/1988 (nie wprowadzono aktualizacji) Kamery TV i LLLTVe Okreslanie zasiegow wykrycia rozpoznania i identyfikacji celow LBSO.PB.06 Edycja 1 z dnia 15.03.2019 r. (zgodnie z metodyka zawarta w zalaczniku A, wycofanego porozumienia standaryzacyjnego STANAG 4347/1988 (nie wprowadzono aktualizacji)","categories":["other"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Determination of detection, recognition and identification ranges of targets","search_en":"TV and LLLTVe cameras Determination of detection, recognition and identification ranges of targets LBSO.PB.06 Edycja 1 z dnia 15.03.2019 r. (zgodnie z metodyką zawartą w załączniku A, wycofanego porozumienia standaryzacyjnego STANAG 4347/1988 (nie wprowadzono aktualizacji)","test_object_en":"TV and LLLTVe cameras","search_zh":"电视摄像机与微光电视（LLLTV）摄像机 LBSO.PB.06 Edycja 1 z dnia 15.03.2019 r. (zgodnie z metodyką zawartą w załączniku A, wycofanego porozumienia standaryzacyjnego STANAG 4347/1988 (nie wprowadzono aktualizacji)","test_object_zh":"电视摄像机与微光电视（LLLTV）摄像机"},{"_id":"6a82ef00884ede9a1b2c4bb6","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Kamery TV i LLLTVe","methodology":"Wyznaczanie pola widzenia(FOV) w zakresie kątów (0,5 – 40)°","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wyznaczanie pola widzenia(FOV) w zakresie kątów (0,5 – 40)°","reference":"LBSO.PB.07 Edycja 1 z dnia 15.03.2019 r.","norm_bases":["LBSO.PB.07 Edycja 1 z dnia 15.03.2019 r."],"lab_section":"Laboratorium Badań Systemów Optoelektronicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kamery TV i LLLTVe Wyznaczanie pola widzenia(FOV) w zakresie kątów (0,5 – 40)° LBSO.PB.07 Edycja 1 z dnia 15.03.2019 r. Kamery TV i LLLTVe Wyznaczanie pola widzenia(FOV) w zakresie katow (0,5 – 40)° LBSO.PB.07 Edycja 1 z dnia 15.03.2019 r.","categories":["other"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","search_en":"TV and LLLTVe cameras LBSO.PB.07 Edycja 1 z dnia 15.03.2019 r.","test_object_en":"TV and LLLTVe cameras","search_zh":"电视摄像机与微光电视（LLLTV）摄像机 LBSO.PB.07 Edycja 1 z dnia 15.03.2019 r.","test_object_zh":"电视摄像机与微光电视（LLLTV）摄像机"},{"_id":"6a82ef00884ede9a1b2c4bb7","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Noktowizory","methodology":"Wyznaczanie charakterystyki minimalnego rozróżnialnego kontrastu (MRC) w zakresie (0,21 – 60) lp/mrad","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wyznaczanie charakterystyki minimalnego rozróżnialnego kontrastu (MRC) w zakresie (0,21 – 60) lp/mrad","reference":"LBSO.PB.08 Edycja 1 z dnia 15.03.2019 r.","norm_bases":["LBSO.PB.08 Edycja 1 z dnia 15.03.2019 r."],"lab_section":"Laboratorium Badań Systemów Optoelektronicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Noktowizory Wyznaczanie charakterystyki minimalnego rozróżnialnego kontrastu (MRC) w zakresie (0,21 – 60) lp/mrad LBSO.PB.08 Edycja 1 z dnia 15.03.2019 r. Noktowizory Wyznaczanie charakterystyki minimalnego rozroznialnego kontrastu (MRC) w zakresie (0,21 – 60) lp/mrad LBSO.PB.08 Edycja 1 z dnia 15.03.2019 r.","categories":["other"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Night vision devices LBSO.PB.08 Edycja 1 z dnia 15.03.2019 r.","test_object_en":"Night vision devices","search_zh":"夜视仪 LBSO.PB.08 Edycja 1 z dnia 15.03.2019 r.","test_object_zh":"夜视仪"},{"_id":"6a82ef00884ede9a1b2c4bb8","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Noktowizory","methodology":"Określanie zasięgów wykrycia rozpoznania i identyfikacji celów","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Określanie zasięgów wykrycia rozpoznania i identyfikacji celów","reference":"LBSO.PB.09 Edycja 1 z dnia 15.03.2019 r. Zgodnie z metodyką zawartą w załączniku A, wycofanego porozumienia standaryzacyjnego STANAG 4347/1988 (nie wprowadzono aktualizacji)","norm_bases":["LBSO.PB.09 Edycja 1 z dnia 15.03.2019 r. Zgodnie z metodyką zawartą w załączniku A, wycofanego porozumienia standaryzacyjnego STANAG 4347/1988 (nie wprowadzono aktualizacji)"],"lab_section":"Laboratorium Badań Systemów Optoelektronicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Noktowizory Określanie zasięgów wykrycia rozpoznania i identyfikacji celów LBSO.PB.09 Edycja 1 z dnia 15.03.2019 r. Zgodnie z metodyką zawartą w załączniku A, wycofanego porozumienia standaryzacyjnego STANAG 4347/1988 (nie wprowadzono aktualizacji) Noktowizory Okreslanie zasiegow wykrycia rozpoznania i identyfikacji celow LBSO.PB.09 Edycja 1 z dnia 15.03.2019 r. Zgodnie z metodyka zawarta w zalaczniku A, wycofanego porozumienia standaryzacyjnego STANAG 4347/1988 (nie wprowadzono aktualizacji)","categories":["other"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Determination of detection, recognition and identification ranges of targets","search_en":"Night vision devices Determination of detection, recognition and identification ranges of targets LBSO.PB.09 Edycja 1 z dnia 15.03.2019 r. Zgodnie z metodyką zawartą w załączniku A, wycofanego porozumienia standaryzacyjnego STANAG 4347/1988 (nie wprowadzono aktualizacji)","test_object_en":"Night vision devices","search_zh":"夜视仪 LBSO.PB.09 Edycja 1 z dnia 15.03.2019 r. Zgodnie z metodyką zawartą w załączniku A, wycofanego porozumienia standaryzacyjnego STANAG 4347/1988 (nie wprowadzono aktualizacji)","test_object_zh":"夜视仪"},{"_id":"6a82ef00884ede9a1b2c4bb9","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Noktowizory","methodology":"Wyznaczanie pola widzenia (FOV) w zakresie kątów (5,0 – 44)°","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wyznaczanie pola widzenia (FOV) w zakresie kątów (5,0 – 44)°","reference":"LBSO.PB.10 Edycja 1 z dnia 15.03.2019 r.","norm_bases":["LBSO.PB.10 Edycja 1 z dnia 15.03.2019 r."],"lab_section":"Laboratorium Badań Systemów Optoelektronicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Noktowizory Wyznaczanie pola widzenia (FOV) w zakresie kątów (5,0 – 44)° LBSO.PB.10 Edycja 1 z dnia 15.03.2019 r. Noktowizory Wyznaczanie pola widzenia (FOV) w zakresie katow (5,0 – 44)° LBSO.PB.10 Edycja 1 z dnia 15.03.2019 r.","categories":["other"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Night vision devices LBSO.PB.10 Edycja 1 z dnia 15.03.2019 r.","test_object_en":"Night vision devices","search_zh":"夜视仪 LBSO.PB.10 Edycja 1 z dnia 15.03.2019 r.","test_object_zh":"夜视仪"},{"_id":"6a82ef00884ede9a1b2c4bba","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Amunicja strzelecka, artyleryjska, moździerzowa, granatnikowa, rakietowa","methodology":"Ciśnienie maksymalne w lufie","parameters":[{"name":"Zakres","range":"(3 – 600) MPa"}],"technique":"Metoda zgniotkowa.","techniques":["Metoda zgniotkowa."],"computed":[],"activity":"Ciśnienie maksymalne w lufie\nZakres (3 – 600) MPa\nMetoda zgniotkowa.","reference":"Procedura LBP.PB.01 Edycja 5 z dnia 20.11.2015","norm_bases":["Procedura LBP.PB.01 Edycja 5 z dnia 20.11.2015"],"lab_section":"Laboratorium Badań Sprzętu Uzbrojenia w Warunkach Poligonowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Amunicja strzelecka, artyleryjska, moździerzowa, granatnikowa, rakietowa Ciśnienie maksymalne w lufie\nZakres (3 – 600) MPa\nMetoda zgniotkowa. Procedura LBP.PB.01 Edycja 5 z dnia 20.11.2015 Amunicja strzelecka, artyleryjska, mozdzierzowa, granatnikowa, rakietowa Cisnienie maksymalne w lufie\nZakres (3 – 600) MPa\nMetoda zgniotkowa. Procedura LBP.PB.01 Edycja 5 z dnia 20.11.2015","categories":["other"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Maximum pressure in the barrel","parameters_en":[{"name":"Range","range":"(3 – 600) MPa"}],"search_en":"Small arms, artillery, mortar, grenade launcher and rocket ammunition Maximum pressure in the barrel Crusher gauge method. Range Procedura LBP.PB.01 Edycja 5 z dnia 20.11.2015","technique_en":"Crusher gauge method.","test_object_en":"Small arms, artillery, mortar, grenade launcher and rocket ammunition","parameters_zh":[{"name":"范围","range":"(3 – 600) MPa"}],"search_zh":"枪弹、炮弹、迫击炮弹、榴弹发射器弹药、火箭弹 范围 Procedura LBP.PB.01 Edycja 5 z dnia 20.11.2015","test_object_zh":"枪弹、炮弹、迫击炮弹、榴弹发射器弹药、火箭弹"},{"_id":"6a82ef00884ede9a1b2c4bbb","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Amunicja strzelecka, artyleryjska, moździerzowa, granatnikowa, rakietowa","methodology":"Prędkość pocisków lub granatów w zakresie (10 – 5000) m/s","parameters":[],"technique":"Metoda radiolokacyjna.","techniques":["Metoda radiolokacyjna."],"computed":[],"activity":"Prędkość pocisków lub granatów w zakresie (10 – 5000) m/s\nMetoda radiolokacyjna.","reference":"Procedura LBP.PB.16 Edycja 2 z dnia 12.08.2015","norm_bases":["Procedura LBP.PB.16 Edycja 2 z dnia 12.08.2015"],"lab_section":"Laboratorium Badań Sprzętu Uzbrojenia w Warunkach Poligonowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Amunicja strzelecka, artyleryjska, moździerzowa, granatnikowa, rakietowa Prędkość pocisków lub granatów w zakresie (10 – 5000) m/s\nMetoda radiolokacyjna. Procedura LBP.PB.16 Edycja 2 z dnia 12.08.2015 Amunicja strzelecka, artyleryjska, mozdzierzowa, granatnikowa, rakietowa Predkosc pociskow lub granatow w zakresie (10 – 5000) m/s\nMetoda radiolokacyjna. Procedura LBP.PB.16 Edycja 2 z dnia 12.08.2015","categories":["other"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Velocity of projectiles or grenades in the range (10 – 5000) m/s","search_en":"Small arms, artillery, mortar, grenade launcher and rocket ammunition Velocity of projectiles or grenades in the range (10 – 5000) m/s Radar method. Procedura LBP.PB.16 Edycja 2 z dnia 12.08.2015","technique_en":"Radar method.","test_object_en":"Small arms, artillery, mortar, grenade launcher and rocket ammunition","search_zh":"枪弹、炮弹、迫击炮弹、榴弹发射器弹药、火箭弹 Procedura LBP.PB.16 Edycja 2 z dnia 12.08.2015","test_object_zh":"枪弹、炮弹、迫击炮弹、榴弹发射器弹药、火箭弹"},{"_id":"6a82ef00884ede9a1b2c4bbc","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Amunicja strzelecka, artyleryjska, moździerzowa, granatnikowa, rakietowa","methodology":"Średnia donośność pocisków, Rozrzut pocisków strzelaniem w teren, Rozrzut (skupienie) przystrzelin na tarczy","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Średnia donośność pocisków, Rozrzut pocisków strzelaniem w teren, Rozrzut (skupienie) przystrzelin na tarczy","reference":"NO-10-A501:2009 NO-10-A501:2009/AC2:2022 NO-10-A502:2009","norm_bases":["NO-10-A501:2009 NO-10-A501:2009/AC2:2022 NO-10-A502:2009"],"lab_section":"Laboratorium Badań Sprzętu Uzbrojenia w Warunkach Poligonowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Amunicja strzelecka, artyleryjska, moździerzowa, granatnikowa, rakietowa Średnia donośność pocisków, Rozrzut pocisków strzelaniem w teren, Rozrzut (skupienie) przystrzelin na tarczy NO-10-A501:2009 NO-10-A501:2009/AC2:2022 NO-10-A502:2009 Amunicja strzelecka, artyleryjska, mozdzierzowa, granatnikowa, rakietowa Srednia donosnosc pociskow, Rozrzut pociskow strzelaniem w teren, Rozrzut (skupienie) przystrzelin na tarczy NO-10-A501:2009 NO-10-A501:2009/AC2:2022 NO-10-A502:2009","categories":["other"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Average projectile range, Projectile dispersion when firing into the field, Dispersion (grouping) of hits on the target","search_en":"Small arms, artillery, mortar, grenade launcher and rocket ammunition Average projectile range, Projectile dispersion when firing into the field, Dispersion (grouping) of hits on the target NO-10-A501:2009 NO-10-A501:2009/AC2:2022 NO-10-A502:2009","test_object_en":"Small arms, artillery, mortar, grenade launcher and rocket ammunition","search_zh":"枪弹、炮弹、迫击炮弹、榴弹发射器弹药、火箭弹 NO-10-A501:2009 NO-10-A501:2009/AC2:2022 NO-10-A502:2009","test_object_zh":"枪弹、炮弹、迫击炮弹、榴弹发射器弹药、火箭弹"},{"_id":"6a82ef00884ede9a1b2c4bbd","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Amunicja strzelecka, artyleryjska, moździerzowa, granatnikowa, rakietowa","methodology":"Trwałość elaboracji skorup pocisków","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Trwałość elaboracji skorup pocisków","reference":"Procedura LBP.PB.04 Edycja 4 z dnia 12.08.2015","norm_bases":["Procedura LBP.PB.04 Edycja 4 z dnia 12.08.2015"],"lab_section":"Laboratorium Badań Sprzętu Uzbrojenia w Warunkach Poligonowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Amunicja strzelecka, artyleryjska, moździerzowa, granatnikowa, rakietowa Trwałość elaboracji skorup pocisków Procedura LBP.PB.04 Edycja 4 z dnia 12.08.2015 Amunicja strzelecka, artyleryjska, mozdzierzowa, granatnikowa, rakietowa Trwalosc elaboracji skorup pociskow Procedura LBP.PB.04 Edycja 4 z dnia 12.08.2015","categories":["other"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Durability of the filling of projectile bodies","search_en":"Small arms, artillery, mortar, grenade launcher and rocket ammunition Durability of the filling of projectile bodies Procedura LBP.PB.04 Edycja 4 z dnia 12.08.2015","test_object_en":"Small arms, artillery, mortar, grenade launcher and rocket ammunition","search_zh":"枪弹、炮弹、迫击炮弹、榴弹发射器弹药、火箭弹 Procedura LBP.PB.04 Edycja 4 z dnia 12.08.2015","test_object_zh":"枪弹、炮弹、迫击炮弹、榴弹发射器弹药、火箭弹"},{"_id":"6a82ef00884ede9a1b2c4bbe","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Amunicja strzelecka, artyleryjska, moździerzowa, granatnikowa, rakietowa","methodology":"Wytrzymałość skorupy pocisku i innych elementów naboju","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość skorupy pocisku i innych elementów naboju","reference":"Procedura LBP.PB.05 Edycja 6 z dnia 08.08.2024","norm_bases":["Procedura LBP.PB.05 Edycja 6 z dnia 08.08.2024"],"lab_section":"Laboratorium Badań Sprzętu Uzbrojenia w Warunkach Poligonowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Amunicja strzelecka, artyleryjska, moździerzowa, granatnikowa, rakietowa Wytrzymałość skorupy pocisku i innych elementów naboju Procedura LBP.PB.05 Edycja 6 z dnia 08.08.2024 Amunicja strzelecka, artyleryjska, mozdzierzowa, granatnikowa, rakietowa Wytrzymalosc skorupy pocisku i innych elementow naboju Procedura LBP.PB.05 Edycja 6 z dnia 08.08.2024","categories":["other"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Strength of the projectile shell and other components of the cartridge","search_en":"Small arms, artillery, mortar, grenade launcher and rocket ammunition Strength of the projectile shell and other components of the cartridge Procedura LBP.PB.05 Edycja 6 z dnia 08.08.2024","test_object_en":"Small arms, artillery, mortar, grenade launcher and rocket ammunition","search_zh":"枪弹、炮弹、迫击炮弹、榴弹发射器弹药、火箭弹 Procedura LBP.PB.05 Edycja 6 z dnia 08.08.2024","test_object_zh":"枪弹、炮弹、迫击炮弹、榴弹发射器弹药、火箭弹"},{"_id":"6a82ef00884ede9a1b2c4bbf","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Zapalniki","methodology":"Bezpieczeństwo użycia zapalnika","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Bezpieczeństwo użycia zapalnika","reference":"Procedura LBP.PB.08 Edycja 6 z dnia 25.03.2016","norm_bases":["Procedura LBP.PB.08 Edycja 6 z dnia 25.03.2016"],"lab_section":"Laboratorium Badań Sprzętu Uzbrojenia w Warunkach Poligonowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zapalniki Bezpieczeństwo użycia zapalnika Procedura LBP.PB.08 Edycja 6 z dnia 25.03.2016 Zapalniki Bezpieczenstwo uzycia zapalnika Procedura LBP.PB.08 Edycja 6 z dnia 25.03.2016","categories":["other"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety of detonator use","search_en":"Fuzes Safety of detonator use Procedura LBP.PB.08 Edycja 6 z dnia 25.03.2016","test_object_en":"Fuzes","search_zh":"雷管 Procedura LBP.PB.08 Edycja 6 z dnia 25.03.2016","test_object_zh":"雷管"},{"_id":"6a82ef00884ede9a1b2c4bc0","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Zapalniki","methodology":"Czułość, niezawodność uzbrajania i działania zapalnika","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Czułość, niezawodność uzbrajania i działania zapalnika","reference":"Procedura LBP.PB.09 Edycja 5 z dnia 14.03.2016","norm_bases":["Procedura LBP.PB.09 Edycja 5 z dnia 14.03.2016"],"lab_section":"Laboratorium Badań Sprzętu Uzbrojenia w Warunkach Poligonowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zapalniki Czułość, niezawodność uzbrajania i działania zapalnika Procedura LBP.PB.09 Edycja 5 z dnia 14.03.2016 Zapalniki Czulosc, niezawodnosc uzbrajania i dzialania zapalnika Procedura LBP.PB.09 Edycja 5 z dnia 14.03.2016","categories":["other"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sensitivity, reliability of arming and functioning of the fuze","search_en":"Fuzes Sensitivity, reliability of arming and functioning of the fuze Procedura LBP.PB.09 Edycja 5 z dnia 14.03.2016","test_object_en":"Fuzes","search_zh":"雷管 Procedura LBP.PB.09 Edycja 5 z dnia 14.03.2016","test_object_zh":"雷管"},{"_id":"6a82ef00884ede9a1b2c4bc1","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Zapalniki","methodology":"Samolikwidacja zapalników strzelaniem","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Samolikwidacja zapalników strzelaniem","reference":"Procedura LBP.PB.10 Edycja 5 z dnia 14.03.2016","norm_bases":["Procedura LBP.PB.10 Edycja 5 z dnia 14.03.2016"],"lab_section":"Laboratorium Badań Sprzętu Uzbrojenia w Warunkach Poligonowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Zapalniki Samolikwidacja zapalników strzelaniem Procedura LBP.PB.10 Edycja 5 z dnia 14.03.2016 Zapalniki Samolikwidacja zapalnikow strzelaniem Procedura LBP.PB.10 Edycja 5 z dnia 14.03.2016","categories":["other"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Self-destruction of detonators by firing","search_en":"Fuzes Self-destruction of detonators by firing Procedura LBP.PB.10 Edycja 5 z dnia 14.03.2016","test_object_en":"Fuzes","search_zh":"雷管 Procedura LBP.PB.10 Edycja 5 z dnia 14.03.2016","test_object_zh":"雷管"},{"_id":"6a82ef00884ede9a1b2c4bc2","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Smugacze artyleryjskie i granatnikowe","methodology":"Wymagania i badania:","parameters":[{"name":"czasu palenia"},{"name":"działania"},{"name":"niezawodności zapalania się"},{"name":"odporności na transport"}],"technique":null,"techniques":[],"computed":[],"activity":"Wymagania i badania:\nZakres:\nczasu palenia\ndziałania\nniezawodności zapalania się\nodporności na transport","reference":"NO-13-A213:2012","norm_bases":["NO-13-A213:2012"],"lab_section":"Laboratorium Badań Sprzętu Uzbrojenia w Warunkach Poligonowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Smugacze artyleryjskie i granatnikowe Wymagania i badania:\nZakres:\nczasu palenia\ndziałania\nniezawodności zapalania się\nodporności na transport NO-13-A213:2012 Smugacze artyleryjskie i granatnikowe Wymagania i badania:\nZakres:\nczasu palenia\ndzialania\nniezawodnosci zapalania sie\nodpornosci na transport NO-13-A213:2012","categories":["other"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Requirements and tests:","parameters_en":[{"name":"burning time"},{"name":"operation"},{"name":"reliability of ignition"},{"name":"resistance to transport"}],"search_en":"Artillery and grenade launcher tracers Requirements and tests: burning time operation reliability of ignition resistance to transport NO-13-A213:2012","test_object_en":"Artillery and grenade launcher tracers"},{"_id":"6a82ef00884ede9a1b2c4bc3","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Amunicja artyleryjska i moździerzowa","methodology":"Działanie kumulacyjne głowicy pocisku","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Działanie kumulacyjne głowicy pocisku","reference":"Procedura LBP.PB.06 Edycja 5 z dnia 12.08.2015","norm_bases":["Procedura LBP.PB.06 Edycja 5 z dnia 12.08.2015"],"lab_section":"Laboratorium Badań Sprzętu Uzbrojenia w Warunkach Poligonowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Amunicja artyleryjska i moździerzowa Działanie kumulacyjne głowicy pocisku Procedura LBP.PB.06 Edycja 5 z dnia 12.08.2015 Amunicja artyleryjska i mozdzierzowa Dzialanie kumulacyjne glowicy pocisku Procedura LBP.PB.06 Edycja 5 z dnia 12.08.2015","categories":["other"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Shaped-charge effect of the projectile warhead","search_en":"Artillery and mortar ammunition Shaped-charge effect of the projectile warhead Procedura LBP.PB.06 Edycja 5 z dnia 12.08.2015","test_object_en":"Artillery and mortar ammunition"},{"_id":"6a82ef00884ede9a1b2c4bc4","lab_id":"69ad52a3de79e566650fb155","country":"PL","accr_number":"AB 171","accr_body":"PCA","test_object":"Amunicja artyleryjska i moździerzowa","methodology":"Badanie zdolności penetracyjnych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badanie zdolności penetracyjnych","reference":"Procedura LBP.PB.07 Edycja 5 z dnia 12.08.2015","norm_bases":["Procedura LBP.PB.07 Edycja 5 z dnia 12.08.2015"],"lab_section":"Laboratorium Badań Sprzętu Uzbrojenia w Warunkach Poligonowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Amunicja artyleryjska i moździerzowa Badanie zdolności penetracyjnych Procedura LBP.PB.07 Edycja 5 z dnia 12.08.2015 Amunicja artyleryjska i mozdzierzowa Badanie zdolnosci penetracyjnych Procedura LBP.PB.07 Edycja 5 z dnia 12.08.2015","categories":["other"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Testing of penetration capability","search_en":"Artillery and mortar ammunition Testing of penetration capability Procedura LBP.PB.07 Edycja 5 z dnia 12.08.2015","test_object_en":"Artillery and mortar ammunition"}],"has_pdf":true}