{"lab":{"_id":"69ad52a3de79e566650fb8fb","country":"PL","accr_number":"AB 1707","accr_body":"PCA","address":"LABORATORIUM, ul. Pakoszowska 1 B, 58-573 Piechowice","categories":["water"],"city":"Piechowice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":9,"name":"WEPA PIECHOWICE Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1707.pdf"],"scope_summary":"","search_text":"wepa piechowice sp. z o.o. laboratorium, ul. pakoszowska 1 b, 58-573 piechowice water other","status":"active","updated_at":"2026-03-08T14:50:49.907Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:49.907Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201707,podmiot.html","fields_of_testing":[{"codes":"C/30/P","pl":"Badania chemiczne i pobieranie próbek ścieków","en":"Chemical tests and sampling of sewage"},{"codes":"N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek ścieków","en":"Tests of physical properties and sampling of sewage"}],"issue":{"no":"9","date":"26.01.2026"},"parse_date":"2026-07-20T07:09:27.673Z","parse_source":"script-pdfplumber","map_coord":[50.856103,15.624341],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":9},"category_scores":{"water":9},"has_zh":true},"methods":[{"_id":"6a5dc9a7f1c10c8ce8259a2b","lab_id":"69ad52a3de79e566650fb8fb","country":"PL","accr_number":"AB 1707","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"technique_en":"Manual method; Automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a5dc9a7f1c10c8ce8259a2c","lab_id":"69ad52a3de79e566650fb8fb","country":"PL","accr_number":"AB 1707","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a5dc9a7f1c10c8ce8259a2d","lab_id":"69ad52a3de79e566650fb8fb","country":"PL","accr_number":"AB 1707","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT","methodology_en":"Chemical oxygen demand - COD","parameters":[{"name":"Zakres","range":"(50 – 1500) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(50 – 1500) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (50 – 1500) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (50 – 1500) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (50 – 1500) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chemical oxygen demand - COD Spectrophotometric method Range PN-ISO 15705:2005","methodology_zh":"化学需氧量 ChZT（COD）","parameters_zh":[{"name":"范围","range":"(50 – 1500) mg/l O2"}],"search_zh":"污水 化学需氧量 ChZT（COD） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9a7f1c10c8ce8259a2e","lab_id":"69ad52a3de79e566650fb8fb","country":"PL","accr_number":"AB 1707","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(6 – 1650) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(6 – 1650) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (6 – 1650) mg/l O2\nMetoda spektrofotometryczna","reference":"Test kuwetowy HACH LCK 554 wydanie 05/2020 wersja 2 Test kuwetowy HACH LCK 555 w y d a n ie 08/2025 wersja 3","norm_bases":["Test kuwetowy HACH LCK 554 wydanie 05/2020 wersja 2 Test kuwetowy HACH LCK 555 w y d a n ie 08/2025 wersja 3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (6 – 1650) mg/l O2\nMetoda spektrofotometryczna Test kuwetowy HACH LCK 554 wydanie 05/2020 wersja 2 Test kuwetowy HACH LCK 555 w y d a n ie 08/2025 wersja 3 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (6 – 1650) mg/l O2\nMetoda spektrofotometryczna Test kuwetowy HACH LCK 554 wydanie 05/2020 wersja 2 Test kuwetowy HACH LCK 555 w y d a n ie 08/2025 wersja 3","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Biochemical oxygen demand Spectrophotometric method BOD5 Range Test kuwetowy HACH LCK 554 wydanie 05/2020 wersja 2 Test kuwetowy HACH LCK 555 w y d a n ie 08/2025 wersja 3","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(6 – 1650) mg/l O2"}],"search_zh":"污水 生化需氧量 分光光度法 BZT5（BOD5） 范围 Test kuwetowy HACH LCK 554 wydanie 05/2020 wersja 2 Test kuwetowy HACH LCK 555 w y d a n ie 08/2025 wersja 3","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9a7f1c10c8ce8259a2f","lab_id":"69ad52a3de79e566650fb8fb","country":"PL","accr_number":"AB 1707","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego","methodology_en":"Total nitrogen concentration","parameters":[{"name":"Zakres","range":"(1 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(1 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego\nZakres (1 – 100) mg/l\nMetoda spektrofotometryczna","reference":"Metodyka HACH LCK 138 wydanie 04/2024 edycja 4","norm_bases":["Metodyka HACH LCK 138 wydanie 04/2024 edycja 4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (1 – 100) mg/l\nMetoda spektrofotometryczna Metodyka HACH LCK 138 wydanie 04/2024 edycja 4 Scieki Stezenie azotu ogolnego\nZakres (1 – 100) mg/l\nMetoda spektrofotometryczna Metodyka HACH LCK 138 wydanie 04/2024 edycja 4","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Range Metodyka HACH LCK 138 wydanie 04/2024 edycja 4","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1 – 100) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 范围 Metodyka HACH LCK 138 wydanie 04/2024 edycja 4","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9a7f1c10c8ce8259a30","lab_id":"69ad52a3de79e566650fb8fb","country":"PL","accr_number":"AB 1707","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,2 – 30) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,2 – 30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,2 – 30) mg/l\nMetoda spektrofotometryczna","reference":"Test kuwetowy HACH LCK 349 wydanie 07/2025 wersja 6","norm_bases":["Test kuwetowy HACH LCK 349 wydanie 07/2025 wersja 6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,2 – 30) mg/l\nMetoda spektrofotometryczna Test kuwetowy HACH LCK 349 wydanie 07/2025 wersja 6 Scieki Stezenie fosforu ogolnego\nZakres (0,2 – 30) mg/l\nMetoda spektrofotometryczna Test kuwetowy HACH LCK 349 wydanie 07/2025 wersja 6","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range Test kuwetowy HACH LCK 349 wydanie 07/2025 wersja 6","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,2 – 30) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 Test kuwetowy HACH LCK 349 wydanie 07/2025 wersja 6","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9a7f1c10c8ce8259a31","lab_id":"69ad52a3de79e566650fb8fb","country":"PL","accr_number":"AB 1707","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2 – 1000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a5dc9a7f1c10c8ce8259a32","lab_id":"69ad52a3de79e566650fb8fb","country":"PL","accr_number":"AB 1707","accr_body":"PCA","test_object":"Wody opadowe, wody roztopowe","test_object_en":"Rainwater, snowmelt water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody opadowe, wody roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11 Wody opadowe, wody roztopowe Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rainwater, snowmelt water Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11","methodology_zh":"化学与物理检测用样品采集","search_zh":"雨水、融雪水 化学与物理检测用样品采集 手工法 PN-ISO 5667-10:2021-11","test_object_zh":"雨水、融雪水","technique_zh":"手工法"},{"_id":"6a5dc9a7f1c10c8ce8259a33","lab_id":"69ad52a3de79e566650fb8fb","country":"PL","accr_number":"AB 1707","accr_body":"PCA","test_object":"Wody opadowe, wody roztopowe","test_object_en":"Rainwater, snowmelt water","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody opadowe, wody roztopowe Zawiesiny ogólne\nZakres (2 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Wody opadowe, wody roztopowe Zawiesiny ogolne\nZakres (2 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rainwater, snowmelt water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2 – 1000) mg/l"}],"search_zh":"雨水、融雪水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"雨水、融雪水"}],"has_pdf":true}