{"lab":{"_id":"69ad52a3de79e566650fb8ef","accr_number":"AB 1698","country":"PL","accr_body":"PCA","address":"al. Mickiewicza 21, 31-120 Kraków, LABORATORIUM EKSPERYMENTALNYCH TECHNIK BADAWCZYCH, SUROWCÓW I PRODUKTÓW BIOLOGICZNYCH, ul. Balicka 116 B","categories":["petro","food","environment"],"city":"Kraków","imported_at":"2026-03-08T10:42:43.265Z","methods_count":6,"name":"UNIWERSYTET ROLNICZY IM. HUGONA KOŁŁĄTAJA W KRAKOWIE","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1698.pdf"],"scope_summary":"","search_text":"uniwersytet rolniczy im. hugona kołłątaja w krakowie al. mickiewicza 21, 31-120 kraków, laboratorium eksperymentalnych technik badawczych, surowców i produktów biologicznych, ul. balicka 116 b petro other environment food","status":"active","updated_at":"2026-03-08T14:50:49.531Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:49.531Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201698,podmiot.html","parse_date":"2026-07-17T16:19:18.068Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/10","pl":"Badania chemiczne paliw stałych","en":"Chemical tests of solid fuels"},{"codes":"N/10","pl":"Badania właściwości fizycznych paliw stałych","en":"Tests of physical properties of solid fuels"},{"codes":"N/22","pl":"Badania właściwości fizycznych żywności","en":"Tests of physical properties of food"}],"issue":{"no":"8","date":"20.11.2025"},"map_coord":[50.04214,19.945624],"map_geo":"nominatim-street","has_zh":true,"has_en":true,"category_counts":{"petro":6,"food":1,"environment":1},"category_scores":{"petro":4.5,"food":0.13,"environment":0.13}},"methods":[{"_id":"6a5a56069af9f73f38254e2e","lab_id":"69ad52a3de79e566650fb8ef","country":"PL","accr_number":"AB 1698","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość wilgoci całkowitej Zakres: (5,0 – 80,0) % Metoda wagowa","methodology_en":"Total moisture content Range: (5,0 – 80,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej Zakres: (5,0 – 80,0) % Metoda wagowa","reference":"PN-EN ISO 18134-1:2023-02","norm_bases":["PN-EN ISO 18134-1:2023-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość wilgoci całkowitej Zakres: (5,0 – 80,0) % Metoda wagowa PN-EN ISO 18134-1:2023-02 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wilgoci calkowitej Zakres: (5,0 – 80,0) % Metoda wagowa PN-EN ISO 18134-1:2023-02","categories":["petro"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"全水分含量 范围：(5,0 – 80,0) % 重量法","search_zh":"固体燃料：固体生物质 – 固体生物燃料 全水分含量 范围：(5,0 – 80,0) % 重量法 PN-EN ISO 18134-1:2023-02","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","search_en":"Solid fuels: solid biomass – solid biofuel Total moisture content Range: (5,0 – 80,0) % Gravimetric method PN-EN ISO 18134-1:2023-02"},{"_id":"6a5a56069af9f73f38254e2f","lab_id":"69ad52a3de79e566650fb8ef","country":"PL","accr_number":"AB 1698","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (3,0 – 15,0) % Metoda wagowa","methodology_en":"Moisture content in the analytical sample Range: (3,0 – 15,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (3,0 – 15,0) % Metoda wagowa","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość wilgoci w próbce analitycznej Zakres: (3,0 – 15,0) % Metoda wagowa PN-EN ISO 18134-3:2023-12 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wilgoci w probce analitycznej Zakres: (3,0 – 15,0) % Metoda wagowa PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"分析样品水分含量 范围：(3,0 – 15,0) % 重量法","search_zh":"固体燃料：固体生物质 – 固体生物燃料 分析样品水分含量 范围：(3,0 – 15,0) % 重量法 PN-EN ISO 18134-3:2023-12","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","search_en":"Solid fuels: solid biomass – solid biofuel Moisture content in the analytical sample Range: (3,0 – 15,0) % Gravimetric method PN-EN ISO 18134-3:2023-12"},{"_id":"6a5a56069af9f73f38254e30","lab_id":"69ad52a3de79e566650fb8ef","country":"PL","accr_number":"AB 1698","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość popiołu Zakres: (0,5 – 40,0) % Metoda wagowa","methodology_en":"Ash content Range: (0,5 – 40,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (0,5 – 40,0) % Metoda wagowa","reference":"PN-EN ISO 18122:2023-05","norm_bases":["PN-EN ISO 18122:2023-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość popiołu Zakres: (0,5 – 40,0) % Metoda wagowa PN-EN ISO 18122:2023-05 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc popiolu Zakres: (0,5 – 40,0) % Metoda wagowa PN-EN ISO 18122:2023-05","categories":["petro"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"灰分含量 范围：(0,5 – 40,0) % 重量法","search_zh":"固体燃料：固体生物质 – 固体生物燃料 灰分含量 范围：(0,5 – 40,0) % 重量法 PN-EN ISO 18122:2023-05","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","search_en":"Solid fuels: solid biomass – solid biofuel Ash content Range: (0,5 – 40,0) % Gravimetric method PN-EN ISO 18122:2023-05"},{"_id":"6a5a56069af9f73f38254e31","lab_id":"69ad52a3de79e566650fb8ef","country":"PL","accr_number":"AB 1698","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Charakterystyczne temperatury topliwości popiołu Zakres: (815 – 1500) ℃ Metoda wysokotemperaturowej mikroskopii","methodology_en":"Characteristic fusibility temperatures of ash Range: (815 – 1500) ℃ High-temperature microscopy method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Charakterystyczne temperatury topliwości popiołu Zakres: (815 – 1500) ℃ Metoda wysokotemperaturowej mikroskopii","reference":"PN-ISO 540:2001","norm_bases":["PN-ISO 540:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Charakterystyczne temperatury topliwości popiołu Zakres: (815 – 1500) ℃ Metoda wysokotemperaturowej mikroskopii PN-ISO 540:2001 Paliwa stale: biomasa stala – biopaliwo stale Charakterystyczne temperatury topliwosci popiolu Zakres: (815 – 1500) ℃ Metoda wysokotemperaturowej mikroskopii PN-ISO 540:2001","categories":["petro"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"灰分特征熔融温度 范围：(815 – 1500) ℃ 高温显微镜法","search_zh":"固体燃料：固体生物质 – 固体生物燃料 灰分特征熔融温度 范围：(815 – 1500) ℃ 高温显微镜法 PN-ISO 540:2001","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","search_en":"Solid fuels: solid biomass – solid biofuel Characteristic fusibility temperatures of ash Range: (815 – 1500) ℃ High-temperature microscopy method PN-ISO 540:2001"},{"_id":"6a5a56069af9f73f38254e32","lab_id":"69ad52a3de79e566650fb8ef","country":"PL","accr_number":"AB 1698","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Ciepło spalania Zakres: (10000 – 25000) J/g Metoda kalorymetryczna Wartość opałowa (z obliczeń)","methodology_en":"Gross calorific value Range: (10000 – 25000) J/g Calorimetric method Net calorific value (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Zakres: (10000 – 25000) J/g Metoda kalorymetryczna Wartość opałowa (z obliczeń)","reference":"PN-EN ISO 18125:2017-07","norm_bases":["PN-EN ISO 18125:2017-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Ciepło spalania Zakres: (10000 – 25000) J/g Metoda kalorymetryczna Wartość opałowa (z obliczeń) PN-EN ISO 18125:2017-07 Paliwa stale: biomasa stala – biopaliwo stale Cieplo spalania Zakres: (10000 – 25000) J/g Metoda kalorymetryczna Wartosc opalowa (z obliczen) PN-EN ISO 18125:2017-07","categories":["petro"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"燃烧热 范围：(10000 – 25000) J/g 量热法 低位发热量（计算得出）","search_zh":"固体燃料：固体生物质 – 固体生物燃料 燃烧热 范围：(10000 – 25000) J/g 量热法 低位发热量（计算得出） PN-EN ISO 18125:2017-07","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","search_en":"Solid fuels: solid biomass – solid biofuel Gross calorific value Range: (10000 – 25000) J/g Calorimetric method Net calorific value (calculated) PN-EN ISO 18125:2017-07"},{"_id":"6a5a56069af9f73f38254e33","lab_id":"69ad52a3de79e566650fb8ef","country":"PL","accr_number":"AB 1698","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe Żywność: owoce i warzywa, napoje alkoholowe, napoje bezalkoholowe, słodycze i wyroby cukiernicze, zboża i przetwory zbożowe, jaja i produkty jajeczne","test_object_en":"Solid fuels: solid biomass – solid biofuel Food: fruit and vegetables, alcoholic beverages, non-alcoholic beverages, sweets and confectionery, cereals and cereal products, eggs and egg products","methodology":"Emisja fotonów Zakres: (20 – 500) impulsy/600 sekund Metoda fotometryczna","methodology_en":"Photon emission Range: (20 – 500) pulses/600 seconds Photometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja fotonów Zakres: (20 – 500) impulsy/600 sekund Metoda fotometryczna","reference":"PB-01 wydanie 6 z dnia 20.06.2025 r.","norm_bases":["PB-01 wydanie 6 z dnia 20.06.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Żywność: owoce i warzywa, napoje alkoholowe, napoje bezalkoholowe, słodycze i wyroby cukiernicze, zboża i przetwory zbożowe, jaja i produkty jajeczne Emisja fotonów Zakres: (20 – 500) impulsy/600 sekund Metoda fotometryczna PB-01 wydanie 6 z dnia 20.06.2025 r. Paliwa stale: biomasa stala – biopaliwo stale Zywnosc: owoce i warzywa, napoje alkoholowe, napoje bezalkoholowe, slodycze i wyroby cukiernicze, zboza i przetwory zbozowe, jaja i produkty jajeczne Emisja fotonow Zakres: (20 – 500) impulsy/600 sekund Metoda fotometryczna PB-01 wydanie 6 z dnia 20.06.2025 r.","categories":["food","petro","environment"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"光子发射 范围：(20 – 500) 计数/600 秒 光度法","search_zh":"固体燃料：固体生物质 – 固体生物燃料 食品：水果与蔬菜、酒精饮料、无酒精饮料、糖果与糕点、谷物与谷物制品、蛋与蛋制品 光子发射 范围：(20 – 500) 计数/600 秒 光度法 PB-01 wydanie 6 z dnia 20.06.2025 r.","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料 食品：水果与蔬菜、酒精饮料、无酒精饮料、糖果与糕点、谷物与谷物制品、蛋与蛋制品","search_en":"Solid fuels: solid biomass – solid biofuel Food: fruit and vegetables, alcoholic beverages, non-alcoholic beverages, sweets and confectionery, cereals and cereal products, eggs and egg products Photon emission Range: (20 – 500) pulses/600 seconds Photometric method PB-01 wydanie 6 z dnia 20.06.2025 r."}],"has_pdf":true}