{"lab":{"_id":"69ad52a3de79e566650fb8e7","accr_number":"AB 1690","country":"PL","accr_body":"PCA","address":"Wierzbięcice 1C, 61-569 Poznań, Laboratorium R&D, ul. Celna 5, 64-300 Nowy Tomyśl","categories":["other"],"city":"Nowy Tomyśl","imported_at":"2026-03-08T10:42:43.265Z","methods_count":14,"name":"Phoenix Contact Business Services Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1690.pdf"],"scope_summary":"","search_text":"phoenix contact business services sp. z o.o. wierzbięcice 1c, 61-569 poznań, laboratorium r&d, ul. celna 5, 64-300 nowy tomyśl materials other metrology environment","status":"active","updated_at":"2026-03-08T14:50:49.273Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T11:19:30.924Z","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%201690,plik.html","parse_date":"2026-08-17T11:19:30.924Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"E/6; E/53; E/54","pl":"Badania elektryczne i elektroniczne wyrobów i wyposażenia elektrycznego, wyrobów i wyposażenia telekomunikacyjnego i wyrobów i wyposażenia elektronicznego","en":"Electric and electronic tests of electrical, telecommunication and electronic products and equipment"},{"codes":"H/6; H/53; H/54","pl":"Badania ogniowe wyrobów i wyposażenia elektrycznego, wyrobów i wyposażenia telekomunikacyjnego i wyrobów i wyposażenia elektronicznego","en":"Fire tests of electrical, telecommunication and electronic products and equipment"},{"codes":"J/6; J/53; J/54","pl":"Badania mechaniczne wyrobów i wyposażenia elektrycznego, wyrobów i wyposażenia telekomunikacyjnego i wyrobów i wyposażenia elektronicznego","en":"Mechanical tests of electrical, telecommunication and electronic products and equipment"},{"codes":"N/6; N/53; N/54","pl":"Badania właściwości fizycznych wyrobów i wyposażenia elektrycznego, wyrobów i wyposażenia telekomunikacyjnego i wyrobów i wyposażenia elektronicznego","en":"Tests of physical properties of electrical, telecommunication and electronic products and equipment"}],"issue":{"no":"11","date":"18.06.2026"},"map_coord":[52.306722,16.12224],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium R&D","address":"ul. Celna 5, 64-300 Nowy Tomyśl","city":"Nowy Tomyśl","postal":"64-300"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/c222a8211680c4a28ae4aed9c38c197c/AB%201690.pdf","has_en":true,"category_counts":{"other":14},"category_scores":{"other":14},"has_zh":true},"methods":[{"_id":"6a82ee42884ede9a1b2c4ace","lab_id":"69ad52a3de79e566650fb8e7","country":"PL","accr_number":"AB 1690","accr_body":"PCA","test_object":"Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozłączalne, Listwy zaciskowe przewodu ochronnego / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks","methodology":"Próba wyciągania przewodów / Testing for damage to and accidental loosening of conductors (pull-out test)","parameters":[{"name":"Zakres","range":"(1 N – 2,5 kN)"},{"name":"Range","range":"(1 N – 2.5 kN)"},{"name":"Próba zginania przewodów / Flexion test"},{"name":"Zakres","range":"(0,1 kg – 22,7 kg)"},{"name":"Range","range":"(0.1 kg – 22.7 kg)"},{"name":"Zamocowanie listwy zaciskowej na jej wsporniku / Attachment of the terminal block on its support"},{"name":"Zakres","range":"(0,2 mm2 – 300 mm2)"},{"name":"Range","range":"(0.2 mm2 – 300 mm2)"},{"name":"Sprawdzenie właściwości termicznych – Badania płomieniem igłowym / Verification of thermal characteristics – Needle flame test"},{"name":"Próba napięcia udarowego wytrzymywanego / Impulse withstand voltage test"},{"name":"Zakres","range":"(0,5 kV – 6 kV)"},{"name":"Range","range":"(0.5 kV – 6 kV)"},{"name":"Próba napięcia wytrzymywanego o częstotliwości sieciowej / Power-frequency withstand voltage test"},{"name":"Zakres","range":"(1 kV – 10 kV)"},{"name":"Range","range":"(1 kV – 10 kV)"},{"name":"Badanie prądem krótkotrwałym wytrzymywanym / Short-time withstand current test"},{"name":"Zakres","range":"(24 A – 1920 A) AC"},{"name":"Range","range":"(24 A – 1920 A) AC"},{"name":"Próba starzenia / Ageing test"},{"name":"Zakres","range":"(20°C – 160°C)"},{"name":"Range","range":"(20°C – 160°C)"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Próba wyciągania przewodów / Testing for damage to and accidental loosening of conductors (pull-out test)\nZakres:\nZakres (1 N – 2,5 kN)\nRange (1 N – 2.5 kN)\nPróba zginania przewodów / Flexion test\nZakres (0,1 kg – 22,7 kg)\nRange (0.1 kg – 22.7 kg)\nZamocowanie listwy zaciskowej na jej wsporniku / Attachment of the terminal block on its support\nZakres (0,2 mm2 – 300 mm2)\nRange (0.2 mm2 – 300 mm2)\nSprawdzenie właściwości termicznych – Badania płomieniem igłowym / Verification of thermal characteristics – Needle flame test\nPróba napięcia udarowego wytrzymywanego / Impulse withstand voltage test\nZakres (0,5 kV – 6 kV)\nRange (0.5 kV – 6 kV)\nPróba napięcia wytrzymywanego o częstotliwości sieciowej / Power-frequency withstand voltage test\nZakres (1 kV – 10 kV)\nRange (1 kV – 10 kV)\nBadanie prądem krótkotrwałym wytrzymywanym / Short-time withstand current test\nZakres (24 A – 1920 A) AC\nRange (24 A – 1920 A) AC\nPróba starzenia / Ageing test\nZakres (20°C – 160°C)\nRange (20°C – 160°C)","reference":"PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009-04 | IEC 60947-7-1:2025-04 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009-04 | IEC 60947-1:2007 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","norm_bases":["PN-EN 60947-7-1:2012","IEC 60947-7-1:2009-04","IEC 60947-7-1:2025-04","PN-EN 60947-7-2:2012","IEC 60947-7-2:2009-04","IEC 60947-1:2007","PN-EN IEC 60947-1:2021-07","IEC 60947-1:2020"],"lab_section":"Laboratorium R&D","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozłączalne, Listwy zaciskowe przewodu ochronnego / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks Próba wyciągania przewodów / Testing for damage to and accidental loosening of conductors (pull-out test)\nZakres:\nZakres (1 N – 2,5 kN)\nRange (1 N – 2.5 kN)\nPróba zginania przewodów / Flexion test\nZakres (0,1 kg – 22,7 kg)\nRange (0.1 kg – 22.7 kg)\nZamocowanie listwy zaciskowej na jej wsporniku / Attachment of the terminal block on its support\nZakres (0,2 mm2 – 300 mm2)\nRange (0.2 mm2 – 300 mm2)\nSprawdzenie właściwości termicznych – Badania płomieniem igłowym / Verification of thermal characteristics – Needle flame test\nPróba napięcia udarowego wytrzymywanego / Impulse withstand voltage test\nZakres (0,5 kV – 6 kV)\nRange (0.5 kV – 6 kV)\nPróba napięcia wytrzymywanego o częstotliwości sieciowej / Power-frequency withstand voltage test\nZakres (1 kV – 10 kV)\nRange (1 kV – 10 kV)\nBadanie prądem krótkotrwałym wytrzymywanym / Short-time withstand current test\nZakres (24 A – 1920 A) AC\nRange (24 A – 1920 A) AC\nPróba starzenia / Ageing test\nZakres (20°C – 160°C)\nRange (20°C – 160°C) PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009-04 | IEC 60947-7-1:2025-04 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009-04 | IEC 60947-1:2007 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozlaczalne, Listwy zaciskowe przewodu ochronnego / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks Proba wyciagania przewodow / Testing for damage to and accidental loosening of conductors (pull-out test)\nZakres:\nZakres (1 N – 2,5 kN)\nRange (1 N – 2.5 kN)\nProba zginania przewodow / Flexion test\nZakres (0,1 kg – 22,7 kg)\nRange (0.1 kg – 22.7 kg)\nZamocowanie listwy zaciskowej na jej wsporniku / Attachment of the terminal block on its support\nZakres (0,2 mm2 – 300 mm2)\nRange (0.2 mm2 – 300 mm2)\nSprawdzenie wlasciwosci termicznych – Badania plomieniem iglowym / Verification of thermal characteristics – Needle flame test\nProba napiecia udarowego wytrzymywanego / Impulse withstand voltage test\nZakres (0,5 kV – 6 kV)\nRange (0.5 kV – 6 kV)\nProba napiecia wytrzymywanego o czestotliwosci sieciowej / Power-frequency withstand voltage test\nZakres (1 kV – 10 kV)\nRange (1 kV – 10 kV)\nBadanie pradem krotkotrwalym wytrzymywanym / Short-time withstand current test\nZakres (24 A – 1920 A) AC\nRange (24 A – 1920 A) AC\nProba starzenia / Ageing test\nZakres (20°C – 160°C)\nRange (20°C – 160°C) PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009-04 | IEC 60947-7-1:2025-04 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009-04 | IEC 60947-1:2007 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"(1 N – 2,5 kN)"},{"name":"Range","range":"(1 N – 2.5 kN)"},{"name":"Próba zginania przewodów / Flexion test"},{"name":"Range","range":"(0,1 kg – 22,7 kg)"},{"name":"Range","range":"(0.1 kg – 22.7 kg)"},{"name":"Zamocowanie listwy zaciskowej na jej wsporniku / Attachment of the terminal block on its support"},{"name":"Range","range":"(0,2 mm2 – 300 mm2)"},{"name":"Range","range":"(0.2 mm2 – 300 mm2)"},{"name":"Sprawdzenie właściwości termicznych – Badania płomieniem igłowym / Verification of thermal characteristics – Needle flame test"},{"name":"Próba napięcia udarowego wytrzymywanego / Impulse withstand voltage test"},{"name":"Range","range":"(0,5 kV – 6 kV)"},{"name":"Range","range":"(0.5 kV – 6 kV)"},{"name":"Próba napięcia wytrzymywanego o częstotliwości sieciowej / Power-frequency withstand voltage test"},{"name":"Range","range":"(1 kV – 10 kV)"},{"name":"Range","range":"(1 kV – 10 kV)"},{"name":"Badanie prądem krótkotrwałym wytrzymywanym / Short-time withstand current test"},{"name":"Range","range":"(24 A – 1920 A) AC"},{"name":"Range","range":"(24 A – 1920 A) AC"},{"name":"Próba starzenia / Ageing test"},{"name":"Range","range":"(20°C – 160°C)"},{"name":"Range","range":"(20°C – 160°C)"}],"search_en":"Range Range Range Range Range Range Range Range Range Range Range Range Range Range Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009-04 | IEC 60947-7-1:2025-04 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009-04 | IEC 60947-1:2007 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","parameters_zh":[{"name":"范围","range":"(1 N – 2,5 kN)"},{"name":"范围","range":"(1 N – 2.5 kN)"},{"name":"Próba zginania przewodów / Flexion test"},{"name":"范围","range":"(0,1 kg – 22,7 kg)"},{"name":"范围","range":"(0.1 kg – 22.7 kg)"},{"name":"Zamocowanie listwy zaciskowej na jej wsporniku / Attachment of the terminal block on its support"},{"name":"范围","range":"(0,2 mm2 – 300 mm2)"},{"name":"范围","range":"(0.2 mm2 – 300 mm2)"},{"name":"Sprawdzenie właściwości termicznych – Badania płomieniem igłowym / Verification of thermal characteristics – Needle flame test"},{"name":"Próba napięcia udarowego wytrzymywanego / Impulse withstand voltage test"},{"name":"范围","range":"(0,5 kV – 6 kV)"},{"name":"范围","range":"(0.5 kV – 6 kV)"},{"name":"Próba napięcia wytrzymywanego o częstotliwości sieciowej / Power-frequency withstand voltage test"},{"name":"范围","range":"(1 kV – 10 kV)"},{"name":"范围","range":"(1 kV – 10 kV)"},{"name":"Badanie prądem krótkotrwałym wytrzymywanym / Short-time withstand current test"},{"name":"范围","range":"(24 A – 1920 A) AC"},{"name":"范围","range":"(24 A – 1920 A) AC"},{"name":"Próba starzenia / Ageing test"},{"name":"范围","range":"(20°C – 160°C)"},{"name":"范围","range":"(20°C – 160°C)"}],"search_zh":"范围 范围 范围 范围 范围 范围 范围 范围 范围 范围 范围 范围 范围 范围 PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009-04 | IEC 60947-7-1:2025-04 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009-04 | IEC 60947-1:2007 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020"},{"_id":"6a82ee42884ede9a1b2c4acf","lab_id":"69ad52a3de79e566650fb8e7","country":"PL","accr_number":"AB 1690","accr_body":"PCA","test_object":"Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozłączalne, Listwy zaciskowe przewodu ochronnego / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks","methodology":"Trwałość listew testowych rozłącznych / Service life","parameters":[{"name":"Zakres","range":"(0,1 mV – 10 V)"},{"name":"Range","range":"(0.1 mV – 10 V)"},{"name":"Sprawdzenie przyrostu temperatury / Temperature rise test"},{"name":"Zakres","range":"(4 A – 520 A) AC"},{"name":"Range","range":"(4 A – 520 A)AC"},{"name":"Spadek napięcia / Voltage drop"},{"name":"Zakres","range":"(0,1 mV – 10 V)"},{"name":"Range","range":"(0.1 mV – 10 V)"},{"name":"Przyłączalność znamionowa / Verification of rated cross-section and rated connecting capacity"},{"name":"Zakres","range":"(0,08 mm2 – 35 mm2)"},{"name":"Range","range":"(0.08 mm2 – 35 mm2)"},{"name":"Właściwości mechaniczne elementów zaciskowych / Test of mechanical strength of clamping units"},{"name":"Zakres","range":"(0,1 mV – 10 V)"},{"name":"Range","range":"(0.1 mV – 10 V)"}],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Trwałość listew testowych rozłącznych / Service life\nZakres:\nZakres (0,1 mV – 10 V)\nRange (0.1 mV – 10 V)\nSprawdzenie przyrostu temperatury / Temperature rise test\nZakres (4 A – 520 A) AC\nRange (4 A – 520 A)AC\nSpadek napięcia / Voltage drop\nZakres (0,1 mV – 10 V)\nRange (0.1 mV – 10 V)\nPrzyłączalność znamionowa / Verification of rated cross-section and rated connecting capacity\nZakres (0,08 mm2 – 35 mm2)\nRange (0.08 mm2 – 35 mm2)\nWłaściwości mechaniczne elementów zaciskowych / Test of mechanical strength of clamping units\nZakres (0,1 mV – 10 V)\nRange (0.1 mV – 10 V)","reference":"PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009-04 | IEC 60947-7-1:2025-04 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009-04 | IEC 60947-1:2007 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","norm_bases":["PN-EN 60947-7-1:2012","IEC 60947-7-1:2009-04","IEC 60947-7-1:2025-04","PN-EN 60947-7-2:2012","IEC 60947-7-2:2009-04","IEC 60947-1:2007","PN-EN IEC 60947-1:2021-07","IEC 60947-1:2020"],"lab_section":"Laboratorium R&D","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozłączalne, Listwy zaciskowe przewodu ochronnego / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks Trwałość listew testowych rozłącznych / Service life\nZakres:\nZakres (0,1 mV – 10 V)\nRange (0.1 mV – 10 V)\nSprawdzenie przyrostu temperatury / Temperature rise test\nZakres (4 A – 520 A) AC\nRange (4 A – 520 A)AC\nSpadek napięcia / Voltage drop\nZakres (0,1 mV – 10 V)\nRange (0.1 mV – 10 V)\nPrzyłączalność znamionowa / Verification of rated cross-section and rated connecting capacity\nZakres (0,08 mm2 – 35 mm2)\nRange (0.08 mm2 – 35 mm2)\nWłaściwości mechaniczne elementów zaciskowych / Test of mechanical strength of clamping units\nZakres (0,1 mV – 10 V)\nRange (0.1 mV – 10 V) PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009-04 | IEC 60947-7-1:2025-04 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009-04 | IEC 60947-1:2007 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020 Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozlaczalne, Listwy zaciskowe przewodu ochronnego / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks Trwalosc listew testowych rozlacznych / Service life\nZakres:\nZakres (0,1 mV – 10 V)\nRange (0.1 mV – 10 V)\nSprawdzenie przyrostu temperatury / Temperature rise test\nZakres (4 A – 520 A) AC\nRange (4 A – 520 A)AC\nSpadek napiecia / Voltage drop\nZakres (0,1 mV – 10 V)\nRange (0.1 mV – 10 V)\nPrzylaczalnosc znamionowa / Verification of rated cross-section and rated connecting capacity\nZakres (0,08 mm2 – 35 mm2)\nRange (0.08 mm2 – 35 mm2)\nWlasciwosci mechaniczne elementow zaciskowych / Test of mechanical strength of clamping units\nZakres (0,1 mV – 10 V)\nRange (0.1 mV – 10 V) PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009-04 | IEC 60947-7-1:2025-04 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009-04 | IEC 60947-1:2007 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"parameters_en":[{"name":"Range","range":"(0,1 mV – 10 V)"},{"name":"Range","range":"(0.1 mV – 10 V)"},{"name":"Sprawdzenie przyrostu temperatury / Temperature rise test"},{"name":"Range","range":"(4 A – 520 A) AC"},{"name":"Range","range":"(4 A – 520 A)AC"},{"name":"Spadek napięcia / Voltage drop"},{"name":"Range","range":"(0,1 mV – 10 V)"},{"name":"Range","range":"(0.1 mV – 10 V)"},{"name":"Przyłączalność znamionowa / Verification of rated cross-section and rated connecting capacity"},{"name":"Range","range":"(0,08 mm2 – 35 mm2)"},{"name":"Range","range":"(0.08 mm2 – 35 mm2)"},{"name":"Właściwości mechaniczne elementów zaciskowych / Test of mechanical strength of clamping units"},{"name":"Range","range":"(0,1 mV – 10 V)"},{"name":"Range","range":"(0.1 mV – 10 V)"}],"search_en":"Range Range Range Range Range Range Range Range Range Range Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009-04 | IEC 60947-7-1:2025-04 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009-04 | IEC 60947-1:2007 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020","parameters_zh":[{"name":"范围","range":"(0,1 mV – 10 V)"},{"name":"范围","range":"(0.1 mV – 10 V)"},{"name":"Sprawdzenie przyrostu temperatury / Temperature rise test"},{"name":"范围","range":"(4 A – 520 A) AC"},{"name":"范围","range":"(4 A – 520 A)AC"},{"name":"Spadek napięcia / Voltage drop"},{"name":"范围","range":"(0,1 mV – 10 V)"},{"name":"范围","range":"(0.1 mV – 10 V)"},{"name":"Przyłączalność znamionowa / Verification of rated cross-section and rated connecting capacity"},{"name":"范围","range":"(0,08 mm2 – 35 mm2)"},{"name":"范围","range":"(0.08 mm2 – 35 mm2)"},{"name":"Właściwości mechaniczne elementów zaciskowych / Test of mechanical strength of clamping units"},{"name":"范围","range":"(0,1 mV – 10 V)"},{"name":"范围","range":"(0.1 mV – 10 V)"}],"search_zh":"范围 范围 范围 范围 范围 范围 范围 范围 范围 范围 PN-EN 60947-7-1:2012 | IEC 60947-7-1:2009-04 | IEC 60947-7-1:2025-04 | PN-EN 60947-7-2:2012 | IEC 60947-7-2:2009-04 | IEC 60947-1:2007 | PN-EN IEC 60947-1:2021-07 | IEC 60947-1:2020"},{"_id":"6a82ee42884ede9a1b2c4ad0","lab_id":"69ad52a3de79e566650fb8e7","country":"PL","accr_number":"AB 1690","accr_body":"PCA","test_object":"Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozłączalne, Listwy zaciskowe przewodu ochronnego / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks","methodology":"Sprawdzenie właściwości termicznych – Badania płomieniem igłowym / Verification of thermal characteristics – Needle flame test","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Sprawdzenie właściwości termicznych – Badania płomieniem igłowym / Verification of thermal characteristics – Needle flame test","reference":"PN-EN 60695-11-5:2017-08 | IEC 60695-11-5:2016","norm_bases":["PN-EN 60695-11-5:2017-08","IEC 60695-11-5:2016"],"lab_section":"Laboratorium R&D","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozłączalne, Listwy zaciskowe przewodu ochronnego / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks Sprawdzenie właściwości termicznych – Badania płomieniem igłowym / Verification of thermal characteristics – Needle flame test PN-EN 60695-11-5:2017-08 | IEC 60695-11-5:2016 Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozlaczalne, Listwy zaciskowe przewodu ochronnego / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks Sprawdzenie wlasciwosci termicznych – Badania plomieniem iglowym / Verification of thermal characteristics – Needle flame test PN-EN 60695-11-5:2017-08 | IEC 60695-11-5:2016","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60695-11-5:2017-08 | IEC 60695-11-5:2016"},{"_id":"6a82ee42884ede9a1b2c4ad1","lab_id":"69ad52a3de79e566650fb8e7","country":"PL","accr_number":"AB 1690","accr_body":"PCA","test_object":"Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozłączalne, Listwy zaciskowe przewodu ochronnego / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks","methodology":"Zagrożenie ogniowe, Badanie rozżarzonym drutem palności wyrobów gotowych / Glow wire test","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Zagrożenie ogniowe, Badanie rozżarzonym drutem palności wyrobów gotowych / Glow wire test","reference":"PN-EN 60695-2-11:2015-02 | PN-EN IEC 60695-2-11:2022-07 | IEC 60695-2-11:2021","norm_bases":["PN-EN 60695-2-11:2015-02","PN-EN IEC 60695-2-11:2022-07","IEC 60695-2-11:2021"],"lab_section":"Laboratorium R&D","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozłączalne, Listwy zaciskowe przewodu ochronnego / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks Zagrożenie ogniowe, Badanie rozżarzonym drutem palności wyrobów gotowych / Glow wire test PN-EN 60695-2-11:2015-02 | PN-EN IEC 60695-2-11:2022-07 | IEC 60695-2-11:2021 Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozlaczalne, Listwy zaciskowe przewodu ochronnego / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks Zagrozenie ogniowe, Badanie rozzarzonym drutem palnosci wyrobow gotowych / Glow wire test PN-EN 60695-2-11:2015-02 | PN-EN IEC 60695-2-11:2022-07 | IEC 60695-2-11:2021","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60695-2-11:2015-02 | PN-EN IEC 60695-2-11:2022-07 | IEC 60695-2-11:2021"},{"_id":"6a82ee42884ede9a1b2c4ad2","lab_id":"69ad52a3de79e566650fb8e7","country":"PL","accr_number":"AB 1690","accr_body":"PCA","test_object":"Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozłączalne, Listwy zaciskowe przewodu ochronnego / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks","methodology":"Badania zagrożenia ogniowego – / Glow wire test","parameters":[],"technique":"Metoda badania rozżarzonym drutem palności wyrobów gotowych","techniques":["Metoda badania rozżarzonym drutem palności wyrobów gotowych"],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Badania zagrożenia ogniowego – / Glow wire test\nMetoda badania rozżarzonym drutem palności wyrobów gotowych","reference":"PN-EN 60695-2-10:2013 | PN-EN IEC 60695-2-10:2022-07 | IEC 60695-2-10:2021","norm_bases":["PN-EN 60695-2-10:2013","PN-EN IEC 60695-2-10:2022-07","IEC 60695-2-10:2021"],"lab_section":"Laboratorium R&D","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozłączalne, Listwy zaciskowe przewodu ochronnego / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks Badania zagrożenia ogniowego – / Glow wire test\nMetoda badania rozżarzonym drutem palności wyrobów gotowych PN-EN 60695-2-10:2013 | PN-EN IEC 60695-2-10:2022-07 | IEC 60695-2-10:2021 Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozlaczalne, Listwy zaciskowe przewodu ochronnego / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks Badania zagrozenia ogniowego – / Glow wire test\nMetoda badania rozzarzonym drutem palnosci wyrobow gotowych PN-EN 60695-2-10:2013 | PN-EN IEC 60695-2-10:2022-07 | IEC 60695-2-10:2021","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60695-2-10:2013 | PN-EN IEC 60695-2-10:2022-07 | IEC 60695-2-10:2021"},{"_id":"6a82ee42884ede9a1b2c4ad3","lab_id":"69ad52a3de79e566650fb8e7","country":"PL","accr_number":"AB 1690","accr_body":"PCA","test_object":"Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozłączalne, Listwy zaciskowe przewodu ochronnego / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks","methodology":"Badanie w atmosferze nasyconej dwutlenkiem siarki / Test in saturated atmosphere containing sulfur dioxide (Kesternich test)","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Badanie w atmosferze nasyconej dwutlenkiem siarki / Test in saturated atmosphere containing sulfur dioxide (Kesternich test)","reference":"PN-EN ISO 22479:2022-12 | EN ISO 22479:2022 | ISO 22479:2019","norm_bases":["PN-EN ISO 22479:2022-12","EN ISO 22479:2022","ISO 22479:2019"],"lab_section":"Laboratorium R&D","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozłączalne, Listwy zaciskowe przewodu ochronnego / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks Badanie w atmosferze nasyconej dwutlenkiem siarki / Test in saturated atmosphere containing sulfur dioxide (Kesternich test) PN-EN ISO 22479:2022-12 | EN ISO 22479:2022 | ISO 22479:2019 Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozlaczalne, Listwy zaciskowe przewodu ochronnego / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks Badanie w atmosferze nasyconej dwutlenkiem siarki / Test in saturated atmosphere containing sulfur dioxide (Kesternich test) PN-EN ISO 22479:2022-12 | EN ISO 22479:2022 | ISO 22479:2019","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents PN-EN ISO 22479:2022-12 | EN ISO 22479:2022 | ISO 22479:2019"},{"_id":"6a82ee42884ede9a1b2c4ad4","lab_id":"69ad52a3de79e566650fb8e7","country":"PL","accr_number":"AB 1690","accr_body":"PCA","test_object":"Złącza wtykowe, wtyki / Pluggable terminal blocks, plugs","methodology":"Mechaniczny test grupy A (test A1, A3, A6, A7) / Mechanical test group A (test A1, A3, A6, A7)","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Mechaniczny test grupy A (test A1, A3, A6, A7) / Mechanical test group A (test A1, A3, A6, A7)","reference":"PN-EN 61984:2009 | IEC 61984:2008 | PN-EN 60512-1-1:2005 | IEC 60512-1-1:2002 | PN-EN 60512-1-2:2005 | IEC 60512-1-2:2002 | PN-EN 60512-13-2:2006 | IEC 60512-13-2:2006 | PN-EN 60512-13-5:2007 | IEC 60512-13-5:2006 | PN-EN 60512-15-1:2010 | IEC 60512-15-1:2008 | PN-EN 60999-1:2002 | IEC 60999-1:1999","norm_bases":["PN-EN 61984:2009","IEC 61984:2008","PN-EN 60512-1-1:2005","IEC 60512-1-1:2002","PN-EN 60512-1-2:2005","IEC 60512-1-2:2002","PN-EN 60512-13-2:2006","IEC 60512-13-2:2006","PN-EN 60512-13-5:2007","IEC 60512-13-5:2006","PN-EN 60512-15-1:2010","IEC 60512-15-1:2008","PN-EN 60999-1:2002","IEC 60999-1:1999"],"lab_section":"Laboratorium R&D","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Złącza wtykowe, wtyki / Pluggable terminal blocks, plugs Mechaniczny test grupy A (test A1, A3, A6, A7) / Mechanical test group A (test A1, A3, A6, A7) PN-EN 61984:2009 | IEC 61984:2008 | PN-EN 60512-1-1:2005 | IEC 60512-1-1:2002 | PN-EN 60512-1-2:2005 | IEC 60512-1-2:2002 | PN-EN 60512-13-2:2006 | IEC 60512-13-2:2006 | PN-EN 60512-13-5:2007 | IEC 60512-13-5:2006 | PN-EN 60512-15-1:2010 | IEC 60512-15-1:2008 | PN-EN 60999-1:2002 | IEC 60999-1:1999 Zlacza wtykowe, wtyki / Pluggable terminal blocks, plugs Mechaniczny test grupy A (test A1, A3, A6, A7) / Mechanical test group A (test A1, A3, A6, A7) PN-EN 61984:2009 | IEC 61984:2008 | PN-EN 60512-1-1:2005 | IEC 60512-1-1:2002 | PN-EN 60512-1-2:2005 | IEC 60512-1-2:2002 | PN-EN 60512-13-2:2006 | IEC 60512-13-2:2006 | PN-EN 60512-13-5:2007 | IEC 60512-13-5:2006 | PN-EN 60512-15-1:2010 | IEC 60512-15-1:2008 | PN-EN 60999-1:2002 | IEC 60999-1:1999","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents PN-EN 61984:2009 | IEC 61984:2008 | PN-EN 60512-1-1:2005 | IEC 60512-1-1:2002 | PN-EN 60512-1-2:2005 | IEC 60512-1-2:2002 | PN-EN 60512-13-2:2006 | IEC 60512-13-2:2006 | PN-EN 60512-13-5:2007 | IEC 60512-13-5:2006 | PN-EN 60512-15-1:2010 | IEC 60512-15-1:2008 | PN-EN 60999-1:2002 | IEC 60999-1:1999"},{"_id":"6a82ee42884ede9a1b2c4ad5","lab_id":"69ad52a3de79e566650fb8e7","country":"PL","accr_number":"AB 1690","accr_body":"PCA","test_object":"Złącza wtykowe, wtyki / Pluggable terminal blocks, plugs","methodology":"Test trwałości użytkowej grupy B (test B1, B3, B4) / Service life test group B (test B1, B3, B4)","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Test trwałości użytkowej grupy B (test B1, B3, B4) / Service life test group B (test B1, B3, B4)","reference":"PN-EN 61984:2009 | IEC 61984:2008 | PN-EN 60512-1-1:2005 | IEC 60512-1-1:2002 | PN-EN 60512-2-1:2006 | IEC 60512-2-1:2002 | PN-EN 60512-2-2:2006 | IEC 60512-2-2:2003 | PN-EN 60512-4-1:2006 | IEC 60512-4-1:2003 | PN-EN 60512-9-1:2010 | IEC 60512-9-1:2010","norm_bases":["PN-EN 61984:2009","IEC 61984:2008","PN-EN 60512-1-1:2005","IEC 60512-1-1:2002","PN-EN 60512-2-1:2006","IEC 60512-2-1:2002","PN-EN 60512-2-2:2006","IEC 60512-2-2:2003","PN-EN 60512-4-1:2006","IEC 60512-4-1:2003","PN-EN 60512-9-1:2010","IEC 60512-9-1:2010"],"lab_section":"Laboratorium R&D","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Złącza wtykowe, wtyki / Pluggable terminal blocks, plugs Test trwałości użytkowej grupy B (test B1, B3, B4) / Service life test group B (test B1, B3, B4) PN-EN 61984:2009 | IEC 61984:2008 | PN-EN 60512-1-1:2005 | IEC 60512-1-1:2002 | PN-EN 60512-2-1:2006 | IEC 60512-2-1:2002 | PN-EN 60512-2-2:2006 | IEC 60512-2-2:2003 | PN-EN 60512-4-1:2006 | IEC 60512-4-1:2003 | PN-EN 60512-9-1:2010 | IEC 60512-9-1:2010 Zlacza wtykowe, wtyki / Pluggable terminal blocks, plugs Test trwalosci uzytkowej grupy B (test B1, B3, B4) / Service life test group B (test B1, B3, B4) PN-EN 61984:2009 | IEC 61984:2008 | PN-EN 60512-1-1:2005 | IEC 60512-1-1:2002 | PN-EN 60512-2-1:2006 | IEC 60512-2-1:2002 | PN-EN 60512-2-2:2006 | IEC 60512-2-2:2003 | PN-EN 60512-4-1:2006 | IEC 60512-4-1:2003 | PN-EN 60512-9-1:2010 | IEC 60512-9-1:2010","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents PN-EN 61984:2009 | IEC 61984:2008 | PN-EN 60512-1-1:2005 | IEC 60512-1-1:2002 | PN-EN 60512-2-1:2006 | IEC 60512-2-1:2002 | PN-EN 60512-2-2:2006 | IEC 60512-2-2:2003 | PN-EN 60512-4-1:2006 | IEC 60512-4-1:2003 | PN-EN 60512-9-1:2010 | IEC 60512-9-1:2010"},{"_id":"6a82ee42884ede9a1b2c4ad6","lab_id":"69ad52a3de79e566650fb8e7","country":"PL","accr_number":"AB 1690","accr_body":"PCA","test_object":"Złącza wtykowe, wtyki / Pluggable terminal blocks, plugs","methodology":"Test temperaturowy grupy C (test C1) / Thermal test group C (test C1)","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Test temperaturowy grupy C (test C1) / Thermal test group C (test C1)","reference":"PN-EN 61984:2009 | IEC 61984:2008 | PN-EN 60512-5-1:2006 | IEC 60512-5-1:2002 | PN-EN 60512-5-2:2005 | IEC 60512-5-2:2002","norm_bases":["PN-EN 61984:2009","IEC 61984:2008","PN-EN 60512-5-1:2006","IEC 60512-5-1:2002","PN-EN 60512-5-2:2005","IEC 60512-5-2:2002"],"lab_section":"Laboratorium R&D","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Złącza wtykowe, wtyki / Pluggable terminal blocks, plugs Test temperaturowy grupy C (test C1) / Thermal test group C (test C1) PN-EN 61984:2009 | IEC 61984:2008 | PN-EN 60512-5-1:2006 | IEC 60512-5-1:2002 | PN-EN 60512-5-2:2005 | IEC 60512-5-2:2002 Zlacza wtykowe, wtyki / Pluggable terminal blocks, plugs Test temperaturowy grupy C (test C1) / Thermal test group C (test C1) PN-EN 61984:2009 | IEC 61984:2008 | PN-EN 60512-5-1:2006 | IEC 60512-5-1:2002 | PN-EN 60512-5-2:2005 | IEC 60512-5-2:2002","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents PN-EN 61984:2009 | IEC 61984:2008 | PN-EN 60512-5-1:2006 | IEC 60512-5-1:2002 | PN-EN 60512-5-2:2005 | IEC 60512-5-2:2002"},{"_id":"6a82ee42884ede9a1b2c4ad7","lab_id":"69ad52a3de79e566650fb8e7","country":"PL","accr_number":"AB 1690","accr_body":"PCA","test_object":"Złącza wtykowe, wtyki / Pluggable terminal blocks, plugs","methodology":"Test klimatyczny grupy D (test D1, D2, D3, D4, D5, D6) / Climatic test group D (test D1, D2, D3, D4, D5, D6)","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Test klimatyczny grupy D (test D1, D2, D3, D4, D5, D6) / Climatic test group D (test D1, D2, D3, D4, D5, D6)","reference":"PN-EN 61984:2009 | IEC 61984:2008 | PN-EN ISO 22479:2022-12 | EN ISO 22479:2022 | ISO 22479:2019 | PN-EN 60512-1-1:2005 | IEC 60512-1-1:2002 | PN-EN 60512-2-1:2006 | IEC 60512-2-1:2002 | PN-EN 60512-2-2:2006 | IEC 60512-2-2:2003 | PN-EN 60512-4-1:2006 | IEC 60512-4-1:2003 | PN-EN 60512-11-9:2006 | IEC 60512-11-9:2002 | PN-EN 60512-11-10:2002 | IEC 60512-11-10:2002 | PN-EN 60068-2-1:2009 | IEC 60068-2-1:2007 | PN-EN 60068-2-2:2009 | IEC 60068-2-2:2007 | PN-EN 60999-1:2002 | IEC 60999-1:1999","norm_bases":["PN-EN 61984:2009","IEC 61984:2008","PN-EN ISO 22479:2022-12","EN ISO 22479:2022","ISO 22479:2019","PN-EN 60512-1-1:2005","IEC 60512-1-1:2002","PN-EN 60512-2-1:2006","IEC 60512-2-1:2002","PN-EN 60512-2-2:2006","IEC 60512-2-2:2003","PN-EN 60512-4-1:2006","IEC 60512-4-1:2003","PN-EN 60512-11-9:2006","IEC 60512-11-9:2002","PN-EN 60512-11-10:2002","IEC 60512-11-10:2002","PN-EN 60068-2-1:2009","IEC 60068-2-1:2007","PN-EN 60068-2-2:2009","IEC 60068-2-2:2007","PN-EN 60999-1:2002","IEC 60999-1:1999"],"lab_section":"Laboratorium R&D","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Złącza wtykowe, wtyki / Pluggable terminal blocks, plugs Test klimatyczny grupy D (test D1, D2, D3, D4, D5, D6) / Climatic test group D (test D1, D2, D3, D4, D5, D6) PN-EN 61984:2009 | IEC 61984:2008 | PN-EN ISO 22479:2022-12 | EN ISO 22479:2022 | ISO 22479:2019 | PN-EN 60512-1-1:2005 | IEC 60512-1-1:2002 | PN-EN 60512-2-1:2006 | IEC 60512-2-1:2002 | PN-EN 60512-2-2:2006 | IEC 60512-2-2:2003 | PN-EN 60512-4-1:2006 | IEC 60512-4-1:2003 | PN-EN 60512-11-9:2006 | IEC 60512-11-9:2002 | PN-EN 60512-11-10:2002 | IEC 60512-11-10:2002 | PN-EN 60068-2-1:2009 | IEC 60068-2-1:2007 | PN-EN 60068-2-2:2009 | IEC 60068-2-2:2007 | PN-EN 60999-1:2002 | IEC 60999-1:1999 Zlacza wtykowe, wtyki / Pluggable terminal blocks, plugs Test klimatyczny grupy D (test D1, D2, D3, D4, D5, D6) / Climatic test group D (test D1, D2, D3, D4, D5, D6) PN-EN 61984:2009 | IEC 61984:2008 | PN-EN ISO 22479:2022-12 | EN ISO 22479:2022 | ISO 22479:2019 | PN-EN 60512-1-1:2005 | IEC 60512-1-1:2002 | PN-EN 60512-2-1:2006 | IEC 60512-2-1:2002 | PN-EN 60512-2-2:2006 | IEC 60512-2-2:2003 | PN-EN 60512-4-1:2006 | IEC 60512-4-1:2003 | PN-EN 60512-11-9:2006 | IEC 60512-11-9:2002 | PN-EN 60512-11-10:2002 | IEC 60512-11-10:2002 | PN-EN 60068-2-1:2009 | IEC 60068-2-1:2007 | PN-EN 60068-2-2:2009 | IEC 60068-2-2:2007 | PN-EN 60999-1:2002 | IEC 60999-1:1999","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents PN-EN 61984:2009 | IEC 61984:2008 | PN-EN ISO 22479:2022-12 | EN ISO 22479:2022 | ISO 22479:2019 | PN-EN 60512-1-1:2005 | IEC 60512-1-1:2002 | PN-EN 60512-2-1:2006 | IEC 60512-2-1:2002 | PN-EN 60512-2-2:2006 | IEC 60512-2-2:2003 | PN-EN 60512-4-1:2006 | IEC 60512-4-1:2003 | PN-EN 60512-11-9:2006 | IEC 60512-11-9:2002 | PN-EN 60512-11-10:2002 | IEC 60512-11-10:2002 | PN-EN 60068-2-1:2009 | IEC 60068-2-1:2007 | PN-EN 60068-2-2:2009 | IEC 60068-2-2:2007 | PN-EN 60999-1:2002 | IEC 60999-1:1999"},{"_id":"6a82ee42884ede9a1b2c4ad8","lab_id":"69ad52a3de79e566650fb8e7","country":"PL","accr_number":"AB 1690","accr_body":"PCA","test_object":"Złącza wtykowe, wtyki / Pluggable terminal blocks, plugs","methodology":"Stopień ochrony, test grupy E (test E1, E2), Ochrona przed dostępem do części niebezpiecznych w zakresie do IP2X / Degree of protection, test group E (test E1, E2), Protected against access to hazardous parts up to IP2X","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Stopień ochrony, test grupy E (test E1, E2), Ochrona przed dostępem do części niebezpiecznych w zakresie do IP2X / Degree of protection, test group E (test E1, E2), Protected against access to hazardous parts up to IP2X","reference":"PN-EN 61984:2009 | IEC 61984:2008 | PN-EN 60529:2003 | IEC 60529:2001 | PN-EN 60512-1-1:2005 | IEC 60512-1-1:2002","norm_bases":["PN-EN 61984:2009","IEC 61984:2008","PN-EN 60529:2003","IEC 60529:2001","PN-EN 60512-1-1:2005","IEC 60512-1-1:2002"],"lab_section":"Laboratorium R&D","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Złącza wtykowe, wtyki / Pluggable terminal blocks, plugs Stopień ochrony, test grupy E (test E1, E2), Ochrona przed dostępem do części niebezpiecznych w zakresie do IP2X / Degree of protection, test group E (test E1, E2), Protected against access to hazardous parts up to IP2X PN-EN 61984:2009 | IEC 61984:2008 | PN-EN 60529:2003 | IEC 60529:2001 | PN-EN 60512-1-1:2005 | IEC 60512-1-1:2002 Zlacza wtykowe, wtyki / Pluggable terminal blocks, plugs Stopien ochrony, test grupy E (test E1, E2), Ochrona przed dostepem do czesci niebezpiecznych w zakresie do IP2X / Degree of protection, test group E (test E1, E2), Protected against access to hazardous parts up to IP2X PN-EN 61984:2009 | IEC 61984:2008 | PN-EN 60529:2003 | IEC 60529:2001 | PN-EN 60512-1-1:2005 | IEC 60512-1-1:2002","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents PN-EN 61984:2009 | IEC 61984:2008 | PN-EN 60529:2003 | IEC 60529:2001 | PN-EN 60512-1-1:2005 | IEC 60512-1-1:2002"},{"_id":"6a82ee42884ede9a1b2c4ad9","lab_id":"69ad52a3de79e566650fb8e7","country":"PL","accr_number":"AB 1690","accr_body":"PCA","test_object":"Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozłączalne, Listwy zaciskowe przewodu ochronnego, Złącza wtykowe, wtyki / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks, Pluggable terminal blocks, plugs","methodology":"Badanie w atmosferze mgły solnej / Salt mist test","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Badanie w atmosferze mgły solnej / Salt mist test","reference":"PN-EN IEC 60068-2-11:2021-11 | IEC 60068-2-11:2021 | PN-EN 60068-1:2014-06 | IEC 60068-1:2013 | PN-EN ISO 9227:2023-02 | ISO 9227:2002","norm_bases":["PN-EN IEC 60068-2-11:2021-11","IEC 60068-2-11:2021","PN-EN 60068-1:2014-06","IEC 60068-1:2013","PN-EN ISO 9227:2023-02","ISO 9227:2002"],"lab_section":"Laboratorium R&D","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozłączalne, Listwy zaciskowe przewodu ochronnego, Złącza wtykowe, wtyki / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks, Pluggable terminal blocks, plugs Badanie w atmosferze mgły solnej / Salt mist test PN-EN IEC 60068-2-11:2021-11 | IEC 60068-2-11:2021 | PN-EN 60068-1:2014-06 | IEC 60068-1:2013 | PN-EN ISO 9227:2023-02 | ISO 9227:2002 Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozlaczalne, Listwy zaciskowe przewodu ochronnego, Zlacza wtykowe, wtyki / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks, Pluggable terminal blocks, plugs Badanie w atmosferze mgly solnej / Salt mist test PN-EN IEC 60068-2-11:2021-11 | IEC 60068-2-11:2021 | PN-EN 60068-1:2014-06 | IEC 60068-1:2013 | PN-EN ISO 9227:2023-02 | ISO 9227:2002","categories":["other"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents PN-EN IEC 60068-2-11:2021-11 | IEC 60068-2-11:2021 | PN-EN 60068-1:2014-06 | IEC 60068-1:2013 | PN-EN ISO 9227:2023-02 | ISO 9227:2002"},{"_id":"6a82ee42884ede9a1b2c4ada","lab_id":"69ad52a3de79e566650fb8e7","country":"PL","accr_number":"AB 1690","accr_body":"PCA","test_object":"Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozłączalne, Listwy zaciskowe przewodu ochronnego, Złącza wtykowe, wtyki / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks, Pluggable terminal blocks, plugs","methodology":"Odporność i wytrzymałość na wibracje i udary (kategoria 1A, 1B, 2) / Vibration test/Shock test (category 1A, 1B, 2)","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Odporność i wytrzymałość na wibracje i udary (kategoria 1A, 1B, 2) / Vibration test/Shock test (category 1A, 1B, 2)","reference":"PN-EN 50155:2022-05 | EN 50155:2021 | PN-EN 61373:2011 | IEC 61373:2010","norm_bases":["PN-EN 50155:2022-05","EN 50155:2021","PN-EN 61373:2011","IEC 61373:2010"],"lab_section":"Laboratorium R&D","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozłączalne, Listwy zaciskowe przewodu ochronnego, Złącza wtykowe, wtyki / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks, Pluggable terminal blocks, plugs Odporność i wytrzymałość na wibracje i udary (kategoria 1A, 1B, 2) / Vibration test/Shock test (category 1A, 1B, 2) PN-EN 50155:2022-05 | EN 50155:2021 | PN-EN 61373:2011 | IEC 61373:2010 Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozlaczalne, Listwy zaciskowe przewodu ochronnego, Zlacza wtykowe, wtyki / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks, Pluggable terminal blocks, plugs Odpornosc i wytrzymalosc na wibracje i udary (kategoria 1A, 1B, 2) / Vibration test/Shock test (category 1A, 1B, 2) PN-EN 50155:2022-05 | EN 50155:2021 | PN-EN 61373:2011 | IEC 61373:2010","categories":["other"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents PN-EN 50155:2022-05 | EN 50155:2021 | PN-EN 61373:2011 | IEC 61373:2010"},{"_id":"6a82ee42884ede9a1b2c4adb","lab_id":"69ad52a3de79e566650fb8e7","country":"PL","accr_number":"AB 1690","accr_body":"PCA","test_object":"Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozłączalne, Listwy zaciskowe przewodu ochronnego, Złącza wtykowe, wtyki / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks, Pluggable terminal blocks, plugs","methodology":"Test spadania – spadek swobodny wielokrotny / Tumble barrel test","parameters":[],"technique":null,"techniques":[],"computed":["Przedmiot badań/wyrób / Material / product tested","Rodzaj działalności/badane cechy/metoda / Type of activity/ parameter/ characteristic tested","Dokumenty odniesienia / Reference documents"],"activity":"Test spadania – spadek swobodny wielokrotny / Tumble barrel test","reference":"PN-EN 60998-1:2006 | IEC 60998-1:2002 | PN-EN 60068-2-31:2010 | IEC 60068-2-31:2008","norm_bases":["PN-EN 60998-1:2006","IEC 60998-1:2002","PN-EN 60068-2-31:2010","IEC 60068-2-31:2008"],"lab_section":"Laboratorium R&D","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozłączalne, Listwy zaciskowe przewodu ochronnego, Złącza wtykowe, wtyki / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks, Pluggable terminal blocks, plugs Test spadania – spadek swobodny wielokrotny / Tumble barrel test PN-EN 60998-1:2006 | IEC 60998-1:2002 | PN-EN 60068-2-31:2010 | IEC 60068-2-31:2008 Listwy zaciskowe z elementami zaciskowymi gwintowanymi lub bezgwintowymi, Listwy zaciskowe testowe rozlaczalne, Listwy zaciskowe przewodu ochronnego, Zlacza wtykowe, wtyki / Terminal blocks with screw-type or screw-less-type clamping units, Disconnect terminal blocks, Protective conductor terminal blocks, Pluggable terminal blocks, plugs Test spadania – spadek swobodny wielokrotny / Tumble barrel test PN-EN 60998-1:2006 | IEC 60998-1:2002 | PN-EN 60068-2-31:2010 | IEC 60068-2-31:2008","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","computed_en":["Przedmiot badań/wyrób / Material / product tested","Type of activity/ parameter/ characteristic tested","Reference documents"],"search_en":"Type of activity/ parameter/ characteristic tested Reference documents PN-EN 60998-1:2006 | IEC 60998-1:2002 | PN-EN 60068-2-31:2010 | IEC 60068-2-31:2008"}],"has_pdf":true}