{"lab":{"_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","address":"ul. Hołubcowa 123, 02-854 Warszawa, LABORATORIUM TECHNOLOGICZNE, ul. Wólczyńska 237","categories":["construction","water"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":43,"name":"PORR S.A.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1689.pdf"],"scope_summary":"","search_text":"porr s.a. ul. hołubcowa 123, 02-854 warszawa, laboratorium technologiczne, ul. wólczyńska 237 other water construction environment","status":"active","updated_at":"2026-03-08T14:50:49.119Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:02:58.704Z","email_confidence":"high","email_mx":true,"email_source":"https://www.porr.pl/en/services/technology-laboratory/contact","parse_date":"2026-08-13T08:02:58.704Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"N/5/P","pl":"Badania właściwości fizycznych i pobieranie próbek wyrobów budowlanych","en":"Tests of physical properties and sampling of building products and building materials"},{"codes":"N/5","pl":"Badania właściwości fizycznych wyrobów i materiałów budowlanych","en":"Tests of physical properties of building products and building materials"},{"codes":"J/5/P","pl":"Badania mechaniczne i pobieranie próbek wyrobów budowlanych","en":"Mechanical tests and sampling of building products"},{"codes":"J/5","pl":"Badania mechaniczne wyrobów budowlanych","en":"Mechanical tests of building products"}],"issue":{"no":"10","date":"01.07.2026"},"map_coord":[52.153996,20.997722],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM TECHNOLOGICZNE","address":"ul. Wólczyńska 237","city":null,"postal":null},{"name":"Laboratorium Centralne","address":"ul. Wólczyńska 237, 01-919 Warszawa","city":"Warszawa","postal":"01-919"},{"name":"Laboratorium Technologiczne; Laboratorium Centralne","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/5dbbc797b9a69f117e6cb1b9ccad3c85/AB%201689.pdf","has_en":true,"category_counts":{"other":26,"construction":15,"water":4},"category_scores":{"other":15.02,"construction":5,"water":0.36},"has_zh":true,"lab_locations_zh":[{"name":"LABORATORIUM TECHNOLOGICZNE","address":"ul. Wólczyńska 237","city":null,"postal":null},{"name":"Laboratorium Centralne","address":"ul. Wólczyńska 237, 01-919 Warszawa","city":"Warszawa","postal":"01-919"},{"name":"工艺实验室；中央实验室","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d7a320636ba417e41b293","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Kruszywa","methodology":"Skład ziarnowy","parameters":[{"name":"Zakres","range":"(0-80) mm"}],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"computed":[],"activity":"Skład ziarnowy\nZakres (0-80) mm\nMetoda przesiewania","reference":"PN-EN 933-1:2012","norm_bases":["PN-EN 933-1:2012"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Skład ziarnowy\nZakres (0-80) mm\nMetoda przesiewania PN-EN 933-1:2012 Kruszywa Sklad ziarnowy\nZakres (0-80) mm\nMetoda przesiewania PN-EN 933-1:2012","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Particle size distribution","parameters_en":[{"name":"Range","range":"(0-80) mm"}],"search_en":"Aggregates Particle size distribution Sieving method Technological Laboratory; Central Laboratory Range PN-EN 933-1:2012","technique_en":"Sieving method","test_object_en":"Aggregates","parameters_zh":[{"name":"范围","range":"(0-80) mm"}],"search_zh":"骨料 粒度分布 筛分法 工艺实验室；中央实验室 范围 PN-EN 933-1:2012","test_object_zh":"骨料","methodology_zh":"粒度分布","lab_section_zh":"工艺实验室；中央实验室","technique_zh":"筛分法"},{"_id":"6a7d7a320636ba417e41b294","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Kruszywa","methodology":"Wskaźnik kształtu","parameters":[{"name":"Zakres","range":"(0-63) mm"}],"technique":"Metoda suwmiarką Schultza","techniques":["Metoda suwmiarką Schultza"],"computed":[],"activity":"Wskaźnik kształtu\nZakres (0-63) mm\nMetoda suwmiarką Schultza","reference":"PN-EN 933-4:2008","norm_bases":["PN-EN 933-4:2008"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Wskaźnik kształtu\nZakres (0-63) mm\nMetoda suwmiarką Schultza PN-EN 933-4:2008 Kruszywa Wskaznik ksztaltu\nZakres (0-63) mm\nMetoda suwmiarka Schultza PN-EN 933-4:2008","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Shape index","parameters_en":[{"name":"Range","range":"(0-63) mm"}],"search_en":"Aggregates Shape index Schultz calliper method Technological Laboratory; Central Laboratory Range PN-EN 933-4:2008","technique_en":"Schultz calliper method","test_object_en":"Aggregates","parameters_zh":[{"name":"范围","range":"(0-63) mm"}],"search_zh":"骨料 形状指数 舒尔茨卡尺法 工艺实验室；中央实验室 范围 PN-EN 933-4:2008","test_object_zh":"骨料","lab_section_zh":"工艺实验室；中央实验室","methodology_zh":"形状指数","technique_zh":"舒尔茨卡尺法"},{"_id":"6a7d7a320636ba417e41b295","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Kruszywa","methodology":"Wskaźnik piaskowy","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik piaskowy","reference":"PN-EN 933-8+A1:2015-07","norm_bases":["PN-EN 933-8+A1:2015-07"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Wskaźnik piaskowy PN-EN 933-8+A1:2015-07 Kruszywa Wskaznik piaskowy PN-EN 933-8+A1:2015-07","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Sand equivalent value","search_en":"Aggregates Sand equivalent value Technological Laboratory; Central Laboratory PN-EN 933-8+A1:2015-07","test_object_en":"Aggregates","search_zh":"骨料 砂当量 工艺实验室；中央实验室 PN-EN 933-8+A1:2015-07","test_object_zh":"骨料","lab_section_zh":"工艺实验室；中央实验室","methodology_zh":"砂当量"},{"_id":"6a7d7a320636ba417e41b296","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Kruszywa","methodology":"Gęstość ziarn i nasiąkliwość","parameters":[{"name":"Zakres","range":"(0,063-31,5) mm"}],"technique":"Metoda piknometryczna","techniques":["Metoda piknometryczna"],"computed":[],"activity":"Gęstość ziarn i nasiąkliwość\nZakres (0,063-31,5) mm\nMetoda piknometryczna","reference":"PN-EN 1097-6:2022-07 p. 8 i 9","norm_bases":["PN-EN 1097-6:2022-07 p. 8 i 9"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Gęstość ziarn i nasiąkliwość\nZakres (0,063-31,5) mm\nMetoda piknometryczna PN-EN 1097-6:2022-07 p. 8 i 9 Kruszywa Gestosc ziarn i nasiakliwosc\nZakres (0,063-31,5) mm\nMetoda piknometryczna PN-EN 1097-6:2022-07 p. 8 i 9","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Particle density and water absorption","parameters_en":[{"name":"Range","range":"(0,063-31,5) mm"}],"search_en":"Aggregates Particle density and water absorption Pycnometric method Technological Laboratory; Central Laboratory Range PN-EN 1097-6:2022-07 p. 8 i 9","technique_en":"Pycnometric method","test_object_en":"Aggregates","parameters_zh":[{"name":"范围","range":"(0,063-31,5) mm"}],"search_zh":"骨料 颗粒密度与吸水率 比重瓶法 工艺实验室；中央实验室 范围 PN-EN 1097-6:2022-07 p. 8 i 9","test_object_zh":"骨料","lab_section_zh":"工艺实验室；中央实验室","technique_zh":"比重瓶法","methodology_zh":"颗粒密度与吸水率"},{"_id":"6a7d7a320636ba417e41b297","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Kruszywa","methodology":"Gęstość ziarn i nasiąkliwość","parameters":[{"name":"Zakres","range":"(31,5-63,0) mm"}],"technique":"Metoda drucianego kosza","techniques":["Metoda drucianego kosza"],"computed":[],"activity":"Gęstość ziarn i nasiąkliwość\nZakres (31,5-63,0) mm\nMetoda drucianego kosza","reference":"PN-EN 1097-6:2022-07 p. 7","norm_bases":["PN-EN 1097-6:2022-07 p. 7"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Gęstość ziarn i nasiąkliwość\nZakres (31,5-63,0) mm\nMetoda drucianego kosza PN-EN 1097-6:2022-07 p. 7 Kruszywa Gestosc ziarn i nasiakliwosc\nZakres (31,5-63,0) mm\nMetoda drucianego kosza PN-EN 1097-6:2022-07 p. 7","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Particle density and water absorption","parameters_en":[{"name":"Range","range":"(31,5-63,0) mm"}],"search_en":"Aggregates Particle density and water absorption Wire basket method Technological Laboratory; Central Laboratory Range PN-EN 1097-6:2022-07 p. 7","technique_en":"Wire basket method","test_object_en":"Aggregates","parameters_zh":[{"name":"范围","range":"(31,5-63,0) mm"}],"search_zh":"骨料 颗粒密度与吸水率 金属丝笼法 工艺实验室；中央实验室 范围 PN-EN 1097-6:2022-07 p. 7","test_object_zh":"骨料","lab_section_zh":"工艺实验室；中央实验室","methodology_zh":"颗粒密度与吸水率","technique_zh":"金属丝笼法"},{"_id":"6a7d7a320636ba417e41b298","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Kruszywa","methodology":"Zawartość wody","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wody","reference":"PN-EN 1097-5:2008","norm_bases":["PN-EN 1097-5:2008"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Zawartość wody PN-EN 1097-5:2008 Kruszywa Zawartosc wody PN-EN 1097-5:2008","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Water content","search_en":"Aggregates Water content Technological Laboratory; Central Laboratory PN-EN 1097-5:2008","test_object_en":"Aggregates","methodology_zh":"水分含量","search_zh":"骨料 水分含量 工艺实验室；中央实验室 PN-EN 1097-5:2008","test_object_zh":"骨料","lab_section_zh":"工艺实验室；中央实验室"},{"_id":"6a7d7a320636ba417e41b299","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Kruszywa","methodology":"Potencjalna reaktywność alkaliczna","parameters":[],"technique":"Metoda szybka","techniques":["Metoda szybka"],"computed":[],"activity":"Potencjalna reaktywność alkaliczna\nMetoda szybka","reference":"PN-92/B-06714/46","norm_bases":["PN-92/B-06714/46"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Potencjalna reaktywność alkaliczna\nMetoda szybka PN-92/B-06714/46 Kruszywa Potencjalna reaktywnosc alkaliczna\nMetoda szybka PN-92/B-06714/46","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Potential alkali reactivity","search_en":"Aggregates Potential alkali reactivity Rapid method Technological Laboratory; Central Laboratory PN-92/B-06714/46","technique_en":"Rapid method","test_object_en":"Aggregates","search_zh":"骨料 工艺实验室；中央实验室 PN-92/B-06714/46","test_object_zh":"骨料","lab_section_zh":"工艺实验室；中央实验室"},{"_id":"6a7d7a320636ba417e41b29a","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Kruszywa","methodology":"Odporność na rozdrabnianie","parameters":[],"technique":"Metoda Los Angeles","techniques":["Metoda Los Angeles"],"computed":[],"activity":"Odporność na rozdrabnianie\nMetoda Los Angeles","reference":"PN-EN 1097-2:2020-09","norm_bases":["PN-EN 1097-2:2020-09"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Odporność na rozdrabnianie\nMetoda Los Angeles PN-EN 1097-2:2020-09 Kruszywa Odpornosc na rozdrabnianie\nMetoda Los Angeles PN-EN 1097-2:2020-09","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Resistance to fragmentation","search_en":"Aggregates Resistance to fragmentation Los Angeles method Technological Laboratory; Central Laboratory PN-EN 1097-2:2020-09","technique_en":"Los Angeles method","test_object_en":"Aggregates","search_zh":"骨料 抗破碎性 洛杉矶法 工艺实验室；中央实验室 PN-EN 1097-2:2020-09","test_object_zh":"骨料","lab_section_zh":"工艺实验室；中央实验室","methodology_zh":"抗破碎性","technique_zh":"洛杉矶法"},{"_id":"6a7d7a320636ba417e41b29b","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Kruszywa","methodology":"Reaktywność alkaliczna","parameters":[],"technique":"Metoda beleczkowa przyspieszona","techniques":["Metoda beleczkowa przyspieszona"],"computed":[],"activity":"Reaktywność alkaliczna\nMetoda beleczkowa przyspieszona","reference":"Procedura badawcza GDDKiA PB/1/18 (marzec 2022 )","norm_bases":["Procedura badawcza GDDKiA PB/1/18 (marzec 2022 )"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Reaktywność alkaliczna\nMetoda beleczkowa przyspieszona Procedura badawcza GDDKiA PB/1/18 (marzec 2022 ) Kruszywa Reaktywnosc alkaliczna\nMetoda beleczkowa przyspieszona Procedura badawcza GDDKiA PB/1/18 (marzec 2022 )","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Alkali reactivity","search_en":"Aggregates Alkali reactivity Accelerated bar method Technological Laboratory; Central Laboratory Procedura badawcza GDDKiA PB/1/18 (marzec 2022 )","technique_en":"Accelerated bar method","test_object_en":"Aggregates","search_zh":"骨料 碱活性 加速小梁法 工艺实验室；中央实验室 Procedura badawcza GDDKiA PB/1/18 (marzec 2022 )","test_object_zh":"骨料","lab_section_zh":"工艺实验室；中央实验室","methodology_zh":"碱活性","technique_zh":"加速小梁法"},{"_id":"6a7d7a320636ba417e41b29c","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Kruszywa","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 932-1:1999 p. 8.8","norm_bases":["PN-EN 932-1:1999 p. 8.8"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kruszywa Pobieranie próbek PN-EN 932-1:1999 p. 8.8 Kruszywa Pobieranie probek PN-EN 932-1:1999 p. 8.8","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Sampling","search_en":"Aggregates Sampling Technological Laboratory; Central Laboratory PN-EN 932-1:1999 p. 8.8","test_object_en":"Aggregates","methodology_zh":"样品采集","search_zh":"骨料 样品采集 工艺实验室；中央实验室 PN-EN 932-1:1999 p. 8.8","test_object_zh":"骨料","lab_section_zh":"工艺实验室；中央实验室"},{"_id":"6a7d7a320636ba417e41b29d","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Konsystencja","parameters":[{"name":"Zakres","range":"(10-210) mm"}],"technique":"Metoda opadu stożka","techniques":["Metoda opadu stożka"],"computed":[],"activity":"Konsystencja\nZakres (10-210) mm\nMetoda opadu stożka","reference":"PN-EN 12350-2:2019-07","norm_bases":["PN-EN 12350-2:2019-07"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Konsystencja\nZakres (10-210) mm\nMetoda opadu stożka PN-EN 12350-2:2019-07 Mieszanka betonowa Konsystencja\nZakres (10-210) mm\nMetoda opadu stozka PN-EN 12350-2:2019-07","categories":["construction"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Consistency","parameters_en":[{"name":"Range","range":"(10-210) mm"}],"search_en":"Fresh concrete Consistency Slump test method Technological Laboratory; Central Laboratory Range PN-EN 12350-2:2019-07","technique_en":"Slump test method","test_object_en":"Fresh concrete","methodology_zh":"稠度","parameters_zh":[{"name":"范围","range":"(10-210) mm"}],"search_zh":"混凝土拌合物 稠度 坍落度法 工艺实验室；中央实验室 范围 PN-EN 12350-2:2019-07","technique_zh":"坍落度法","test_object_zh":"混凝土拌合物","lab_section_zh":"工艺实验室；中央实验室"},{"_id":"6a7d7a320636ba417e41b29e","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Konsystencja","parameters":[{"name":"Zakres","range":"(340-630) mm"}],"technique":"Metoda stolika rozpływowego","techniques":["Metoda stolika rozpływowego"],"computed":[],"activity":"Konsystencja\nZakres (340-630) mm\nMetoda stolika rozpływowego","reference":"PN-EN 12350-5:2019-08","norm_bases":["PN-EN 12350-5:2019-08"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Konsystencja\nZakres (340-630) mm\nMetoda stolika rozpływowego PN-EN 12350-5:2019-08 Mieszanka betonowa Konsystencja\nZakres (340-630) mm\nMetoda stolika rozplywowego PN-EN 12350-5:2019-08","categories":["construction"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Consistency","parameters_en":[{"name":"Range","range":"(340-630) mm"}],"search_en":"Fresh concrete Consistency Flow table method Technological Laboratory; Central Laboratory Range PN-EN 12350-5:2019-08","technique_en":"Flow table method","test_object_en":"Fresh concrete","methodology_zh":"稠度","parameters_zh":[{"name":"范围","range":"(340-630) mm"}],"search_zh":"混凝土拌合物 稠度 跳桌法 工艺实验室；中央实验室 范围 PN-EN 12350-5:2019-08","test_object_zh":"混凝土拌合物","lab_section_zh":"工艺实验室；中央实验室","technique_zh":"跳桌法"},{"_id":"6a7d7a320636ba417e41b29f","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Zawartość powietrza","parameters":[{"name":"Zakres","range":"(0,1-10) %"}],"technique":"Metoda ciśnieniomierza","techniques":["Metoda ciśnieniomierza"],"computed":[],"activity":"Zawartość powietrza\nZakres (0,1-10) %\nMetoda ciśnieniomierza","reference":"PN-EN 12350-7:2019-08 z wyłączeniem punktu 5","norm_bases":["PN-EN 12350-7:2019-08 z wyłączeniem punktu 5"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Zawartość powietrza\nZakres (0,1-10) %\nMetoda ciśnieniomierza PN-EN 12350-7:2019-08 z wyłączeniem punktu 5 Mieszanka betonowa Zawartosc powietrza\nZakres (0,1-10) %\nMetoda cisnieniomierza PN-EN 12350-7:2019-08 z wylaczeniem punktu 5","categories":["construction"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Air content","parameters_en":[{"name":"Range","range":"(0,1-10) %"}],"search_en":"Fresh concrete Air content Pressure gauge method Technological Laboratory; Central Laboratory Range PN-EN 12350-7:2019-08 z wyłączeniem punktu 5","technique_en":"Pressure gauge method","test_object_en":"Fresh concrete","methodology_zh":"含气量","parameters_zh":[{"name":"范围","range":"(0,1-10) %"}],"search_zh":"混凝土拌合物 含气量 压力计法 工艺实验室；中央实验室 范围 PN-EN 12350-7:2019-08 z wyłączeniem punktu 5","technique_zh":"压力计法","test_object_zh":"混凝土拌合物","lab_section_zh":"工艺实验室；中央实验室"},{"_id":"6a7d7a320636ba417e41b2a0","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Gęstość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość","reference":"PN-EN 12350-6:2019-08","norm_bases":["PN-EN 12350-6:2019-08"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Gęstość PN-EN 12350-6:2019-08 Mieszanka betonowa Gestosc PN-EN 12350-6:2019-08","categories":["construction"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Density","search_en":"Fresh concrete Density Technological Laboratory; Central Laboratory PN-EN 12350-6:2019-08","test_object_en":"Fresh concrete","methodology_zh":"密度","search_zh":"混凝土拌合物 密度 工艺实验室；中央实验室 PN-EN 12350-6:2019-08","test_object_zh":"混凝土拌合物","lab_section_zh":"工艺实验室；中央实验室"},{"_id":"6a7d7a320636ba417e41b2a1","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 12350-1:2019-07","norm_bases":["PN-EN 12350-1:2019-07"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Pobieranie próbek PN-EN 12350-1:2019-07 Mieszanka betonowa Pobieranie probek PN-EN 12350-1:2019-07","categories":["construction"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Sampling","search_en":"Fresh concrete Sampling Technological Laboratory; Central Laboratory PN-EN 12350-1:2019-07","test_object_en":"Fresh concrete","methodology_zh":"样品采集","search_zh":"混凝土拌合物 样品采集 工艺实验室；中央实验室 PN-EN 12350-1:2019-07","test_object_zh":"混凝土拌合物","lab_section_zh":"工艺实验室；中央实验室"},{"_id":"6a7d7a320636ba417e41b2a2","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres siły","range":"(30-3000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres siły (30-3000) kN","reference":"PN-EN 12390-3:2011 | PN-EN 12390-3:2011/AC:2012 | PN EN 12390-3:2019-07","norm_bases":["PN-EN 12390-3:2011","PN-EN 12390-3:2011/AC:2012","PN EN 12390-3:2019-07"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na ściskanie\nZakres siły (30-3000) kN PN-EN 12390-3:2011 | PN-EN 12390-3:2011/AC:2012 | PN EN 12390-3:2019-07 Beton Wytrzymalosc na sciskanie\nZakres sily (30-3000) kN PN-EN 12390-3:2011 | PN-EN 12390-3:2011/AC:2012 | PN EN 12390-3:2019-07","categories":["construction"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Compressive strength","parameters_en":[{"name":"Force range","range":"(30-3000) kN"}],"search_en":"Concrete Compressive strength Technological Laboratory; Central Laboratory Force range PN-EN 12390-3:2011 | PN-EN 12390-3:2011/AC:2012 | PN EN 12390-3:2019-07","test_object_en":"Concrete","methodology_zh":"抗压强度","parameters_zh":[{"name":"力值范围","range":"(30-3000) kN"}],"search_zh":"混凝土 抗压强度 工艺实验室；中央实验室 力值范围 PN-EN 12390-3:2011 | PN-EN 12390-3:2011/AC:2012 | PN EN 12390-3:2019-07","test_object_zh":"混凝土","lab_section_zh":"工艺实验室；中央实验室"},{"_id":"6a7d7a320636ba417e41b2a3","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Beton","methodology":"Gęstość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Gęstość","reference":"PN-EN 12390-7:2011 | PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","norm_bases":["PN-EN 12390-7:2011","PN-EN 12390-7:2019-08","PN-EN 12390-7:2019-08/AC:2021-01"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Gęstość PN-EN 12390-7:2011 | PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01 Beton Gestosc PN-EN 12390-7:2011 | PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","categories":["construction"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Density","search_en":"Concrete Density Technological Laboratory; Central Laboratory PN-EN 12390-7:2011 | PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","test_object_en":"Concrete","methodology_zh":"密度","search_zh":"混凝土 密度 工艺实验室；中央实验室 PN-EN 12390-7:2011 | PN-EN 12390-7:2019-08 | PN-EN 12390-7:2019-08/AC:2021-01","test_object_zh":"混凝土","lab_section_zh":"工艺实验室；中央实验室"},{"_id":"6a7d7a320636ba417e41b2a4","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Beton","methodology":"Odporność na zamrażanie i rozmrażanie w obecności soli odladzających","parameters":[],"technique":"Metoda Slab test","techniques":["Metoda Slab test"],"computed":[],"activity":"Odporność na zamrażanie i rozmrażanie w obecności soli odladzających\nMetoda Slab test","reference":"PKN-CEN/TS 12390-9:2017-07","norm_bases":["PKN-CEN/TS 12390-9:2017-07"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Odporność na zamrażanie i rozmrażanie w obecności soli odladzających\nMetoda Slab test PKN-CEN/TS 12390-9:2017-07 Beton Odpornosc na zamrazanie i rozmrazanie w obecnosci soli odladzajacych\nMetoda Slab test PKN-CEN/TS 12390-9:2017-07","categories":["construction"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Freeze-thaw resistance in the presence of de-icing salts","search_en":"Concrete Freeze-thaw resistance in the presence of de-icing salts Slab test method Technological Laboratory; Central Laboratory PKN-CEN/TS 12390-9:2017-07","technique_en":"Slab test method","test_object_en":"Concrete","search_zh":"混凝土 含除冰盐的抗冻融性 工艺实验室；中央实验室 PKN-CEN/TS 12390-9:2017-07","test_object_zh":"混凝土","lab_section_zh":"工艺实验室；中央实验室","methodology_zh":"含除冰盐的抗冻融性"},{"_id":"6a7d7a320636ba417e41b2a5","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Beton","methodology":"Odporność na działanie mrozu","parameters":[],"technique":"Metoda zwykła","techniques":["Metoda zwykła"],"computed":[],"activity":"Odporność na działanie mrozu\nMetoda zwykła","reference":"PN-88/B-06250 pkt 6.5.1 | PN-B-06265:2022-08, Załącznik N","norm_bases":["PN-88/B-06250 pkt 6.5.1","PN-B-06265:2022-08, Załącznik N"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Odporność na działanie mrozu\nMetoda zwykła PN-88/B-06250 pkt 6.5.1 | PN-B-06265:2022-08, Załącznik N Beton Odpornosc na dzialanie mrozu\nMetoda zwykla PN-88/B-06250 pkt 6.5.1 | PN-B-06265:2022-08, Zalacznik N","categories":["construction"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Resistance to freezing","search_en":"Concrete Resistance to freezing Ordinary method Technological Laboratory; Central Laboratory PN-88/B-06250 pkt 6.5.1 | PN-B-06265:2022-08, Załącznik N","technique_en":"Ordinary method","test_object_en":"Concrete","methodology_zh":"抗冻性","search_zh":"混凝土 抗冻性 常规法 工艺实验室；中央实验室 PN-88/B-06250 pkt 6.5.1 | PN-B-06265:2022-08, Załącznik N","test_object_zh":"混凝土","lab_section_zh":"工艺实验室；中央实验室","technique_zh":"常规法"},{"_id":"6a7d7a320636ba417e41b2a6","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Beton","methodology":"Przepuszczalność wody","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Przepuszczalność wody","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Przepuszczalność wody PN-88/B-06250 Beton Przepuszczalnosc wody PN-88/B-06250","categories":["water","construction"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Water permeability","search_en":"Concrete Water permeability Technological Laboratory; Central Laboratory PN-88/B-06250","test_object_en":"Concrete","methodology_zh":"透水性","search_zh":"混凝土 透水性 工艺实验室；中央实验室 PN-88/B-06250","test_object_zh":"混凝土","lab_section_zh":"工艺实验室；中央实验室"},{"_id":"6a7d7a320636ba417e41b2a7","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Beton","methodology":"Nasiąkliwość","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Nasiąkliwość","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Nasiąkliwość PN-88/B-06250 Beton Nasiakliwosc PN-88/B-06250","categories":["construction"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Water absorption","search_en":"Concrete Water absorption Technological Laboratory; Central Laboratory PN-88/B-06250","test_object_en":"Concrete","methodology_zh":"吸水率","search_zh":"混凝土 吸水率 工艺实验室；中央实验室 PN-88/B-06250","test_object_zh":"混凝土","lab_section_zh":"工艺实验室；中央实验室"},{"_id":"6a7d7a320636ba417e41b2a8","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Beton","methodology":"Głębokość penetracji wody pod ciśnieniem","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Głębokość penetracji wody pod ciśnieniem","reference":"PN-EN 12390-8:2019-08","norm_bases":["PN-EN 12390-8:2019-08"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Głębokość penetracji wody pod ciśnieniem PN-EN 12390-8:2019-08 Beton Glebokosc penetracji wody pod cisnieniem PN-EN 12390-8:2019-08","categories":["water","construction"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Depth of penetration of water under pressure","search_en":"Concrete Depth of penetration of water under pressure Technological Laboratory; Central Laboratory PN-EN 12390-8:2019-08","test_object_en":"Concrete","methodology_zh":"压力水渗透深度","search_zh":"混凝土 压力水渗透深度 工艺实验室；中央实验室 PN-EN 12390-8:2019-08","test_object_zh":"混凝土","lab_section_zh":"工艺实验室；中央实验室"},{"_id":"6a7d7a320636ba417e41b2a9","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na zginanie","parameters":[{"name":"Zakres siły","range":"(2-200) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na zginanie\nZakres siły (2-200) kN","reference":"PN-EN 12390-5:2011 | PN-EN 12390-5:2019-08","norm_bases":["PN-EN 12390-5:2011","PN-EN 12390-5:2019-08"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na zginanie\nZakres siły (2-200) kN PN-EN 12390-5:2011 | PN-EN 12390-5:2019-08 Beton Wytrzymalosc na zginanie\nZakres sily (2-200) kN PN-EN 12390-5:2011 | PN-EN 12390-5:2019-08","categories":["construction"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Flexural strength","parameters_en":[{"name":"Force range","range":"(2-200) kN"}],"search_en":"Concrete Flexural strength Technological Laboratory; Central Laboratory Force range PN-EN 12390-5:2011 | PN-EN 12390-5:2019-08","test_object_en":"Concrete","parameters_zh":[{"name":"力值范围","range":"(2-200) kN"}],"search_zh":"混凝土 抗弯强度 工艺实验室；中央实验室 力值范围 PN-EN 12390-5:2011 | PN-EN 12390-5:2019-08","test_object_zh":"混凝土","methodology_zh":"抗弯强度","lab_section_zh":"工艺实验室；中央实验室"},{"_id":"6a7d7a320636ba417e41b2aa","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na rozciąganie przy rozłupywaniu","parameters":[{"name":"Zakres siły","range":"(30-3000) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres siły (30-3000) kN","reference":"PN-EN 12390-6:2011 | PN-EN 12390-6:2024-04","norm_bases":["PN-EN 12390-6:2011","PN-EN 12390-6:2024-04"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na rozciąganie przy rozłupywaniu\nZakres siły (30-3000) kN PN-EN 12390-6:2011 | PN-EN 12390-6:2024-04 Beton Wytrzymalosc na rozciaganie przy rozlupywaniu\nZakres sily (30-3000) kN PN-EN 12390-6:2011 | PN-EN 12390-6:2024-04","categories":["construction"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Splitting tensile strength","parameters_en":[{"name":"Force range","range":"(30-3000) kN"}],"search_en":"Concrete Splitting tensile strength Technological Laboratory; Central Laboratory Force range PN-EN 12390-6:2011 | PN-EN 12390-6:2024-04","test_object_en":"Concrete","methodology_zh":"劈裂抗拉强度","parameters_zh":[{"name":"力值范围","range":"(30-3000) kN"}],"search_zh":"混凝土 劈裂抗拉强度 工艺实验室；中央实验室 力值范围 PN-EN 12390-6:2011 | PN-EN 12390-6:2024-04","test_object_zh":"混凝土","lab_section_zh":"工艺实验室；中央实验室"},{"_id":"6a7d7a320636ba417e41b2ab","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Beton w konstrukcji","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 12504-1:2019-08","norm_bases":["PN-EN 12504-1:2019-08"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton w konstrukcji Pobieranie próbek PN-EN 12504-1:2019-08 Beton w konstrukcji Pobieranie probek PN-EN 12504-1:2019-08","categories":["construction"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Sampling","search_en":"Concrete in structures Sampling Technological Laboratory; Central Laboratory PN-EN 12504-1:2019-08","test_object_en":"Concrete in structures","methodology_zh":"样品采集","search_zh":"结构中的混凝土 样品采集 工艺实验室；中央实验室 PN-EN 12504-1:2019-08","lab_section_zh":"工艺实验室；中央实验室","test_object_zh":"结构中的混凝土"},{"_id":"6a7d7a320636ba417e41b2ac","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe","methodology":"Gęstość w wodzie","parameters":[{"name":"Zakres","range":"(2,000-3,300) Mg/m3"}],"technique":"Metoda A","techniques":["Metoda A"],"computed":[],"activity":"Gęstość w wodzie\nZakres (2,000-3,300) Mg/m3\nMetoda A","reference":"PN-EN 12697-5:2019-01","norm_bases":["PN-EN 12697-5:2019-01"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe Gęstość w wodzie\nZakres (2,000-3,300) Mg/m3\nMetoda A PN-EN 12697-5:2019-01 Mieszanki mineralno-asfaltowe Gestosc w wodzie\nZakres (2,000-3,300) Mg/m3\nMetoda A PN-EN 12697-5:2019-01","categories":["other"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Density in water","parameters_en":[{"name":"Range","range":"(2,000-3,300) Mg/m3"}],"search_en":"Bituminous mixtures Density in water Method A Technological Laboratory; Central Laboratory Range PN-EN 12697-5:2019-01","technique_en":"Method A","test_object_en":"Bituminous mixtures","parameters_zh":[{"name":"范围","range":"(2,000-3,300) Mg/m3"}],"search_zh":"沥青混合料 水中密度 方法 A 工艺实验室；中央实验室 范围 PN-EN 12697-5:2019-01","test_object_zh":"沥青混合料","lab_section_zh":"工艺实验室；中央实验室","methodology_zh":"水中密度","technique_zh":"方法 A"},{"_id":"6a7d7a320636ba417e41b2ad","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe","methodology":"Gęstość objętościowa","parameters":[{"name":"Zakres","range":"(2,000-2,750) Mg/m3"}],"technique":"Metoda B","techniques":["Metoda B"],"computed":[],"activity":"Gęstość objętościowa\nZakres (2,000-2,750) Mg/m3\nMetoda B","reference":"PN-EN 12697-6:2020-07","norm_bases":["PN-EN 12697-6:2020-07"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe Gęstość objętościowa\nZakres (2,000-2,750) Mg/m3\nMetoda B PN-EN 12697-6:2020-07 Mieszanki mineralno-asfaltowe Gestosc objetosciowa\nZakres (2,000-2,750) Mg/m3\nMetoda B PN-EN 12697-6:2020-07","categories":["other"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Bulk density","parameters_en":[{"name":"Range","range":"(2,000-2,750) Mg/m3"}],"search_en":"Bituminous mixtures Bulk density Method B Technological Laboratory; Central Laboratory Range PN-EN 12697-6:2020-07","technique_en":"Method B","test_object_en":"Bituminous mixtures","parameters_zh":[{"name":"范围","range":"(2,000-2,750) Mg/m3"}],"search_zh":"沥青混合料 堆积密度 方法 B 工艺实验室；中央实验室 范围 PN-EN 12697-6:2020-07","test_object_zh":"沥青混合料","lab_section_zh":"工艺实验室；中央实验室","methodology_zh":"堆积密度","technique_zh":"方法 B"},{"_id":"6a7d7a320636ba417e41b2ae","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe","methodology":"Zawartość lepiszcza rozpuszczalnego","parameters":[{"name":"Zakres","range":"(2-10) %"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość lepiszcza rozpuszczalnego\nZakres (2-10) %","reference":"PN-EN 12697-1:2012 p. B.1.2 | PN-EN 12697-1:2020-08 p. B.1.7","norm_bases":["PN-EN 12697-1:2012 p. B.1.2","PN-EN 12697-1:2020-08 p. B.1.7"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe Zawartość lepiszcza rozpuszczalnego\nZakres (2-10) % PN-EN 12697-1:2012 p. B.1.2 | PN-EN 12697-1:2020-08 p. B.1.7 Mieszanki mineralno-asfaltowe Zawartosc lepiszcza rozpuszczalnego\nZakres (2-10) % PN-EN 12697-1:2012 p. B.1.2 | PN-EN 12697-1:2020-08 p. B.1.7","categories":["other"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Soluble binder content","parameters_en":[{"name":"Range","range":"(2-10) %"}],"search_en":"Bituminous mixtures Soluble binder content Technological Laboratory; Central Laboratory Range PN-EN 12697-1:2012 p. B.1.2 | PN-EN 12697-1:2020-08 p. B.1.7","test_object_en":"Bituminous mixtures","parameters_zh":[{"name":"范围","range":"(2-10) %"}],"search_zh":"沥青混合料 可溶性胶结料含量 工艺实验室；中央实验室 范围 PN-EN 12697-1:2012 p. B.1.2 | PN-EN 12697-1:2020-08 p. B.1.7","test_object_zh":"沥青混合料","lab_section_zh":"工艺实验室；中央实验室","methodology_zh":"可溶性胶结料含量"},{"_id":"6a7d7a320636ba417e41b2af","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe","methodology":"Uziarnienie","parameters":[{"name":"Zakres","range":"(0-45) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Uziarnienie\nZakres (0-45) mm","reference":"PN-EN 12697-2+A1:2019-12 | PN-EN 12697-2:2025-06 | PN-EN 933-1:2012","norm_bases":["PN-EN 12697-2+A1:2019-12","PN-EN 12697-2:2025-06","PN-EN 933-1:2012"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe Uziarnienie\nZakres (0-45) mm PN-EN 12697-2+A1:2019-12 | PN-EN 12697-2:2025-06 | PN-EN 933-1:2012 Mieszanki mineralno-asfaltowe Uziarnienie\nZakres (0-45) mm PN-EN 12697-2+A1:2019-12 | PN-EN 12697-2:2025-06 | PN-EN 933-1:2012","categories":["other"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Grading","parameters_en":[{"name":"Range","range":"(0-45) mm"}],"search_en":"Bituminous mixtures Grading Technological Laboratory; Central Laboratory Range PN-EN 12697-2+A1:2019-12 | PN-EN 12697-2:2025-06 | PN-EN 933-1:2012","test_object_en":"Bituminous mixtures","parameters_zh":[{"name":"范围","range":"(0-45) mm"}],"search_zh":"沥青混合料 级配 工艺实验室；中央实验室 范围 PN-EN 12697-2+A1:2019-12 | PN-EN 12697-2:2025-06 | PN-EN 933-1:2012","test_object_zh":"沥青混合料","lab_section_zh":"工艺实验室；中央实验室","methodology_zh":"级配"},{"_id":"6a7d7a320636ba417e41b2b0","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe","methodology":"Wrażliwość na działanie wody","parameters":[],"technique":"Metoda A","techniques":["Metoda A"],"computed":[],"activity":"Wrażliwość na działanie wody\nMetoda A","reference":"PN-EN 12697-12:2018-08","norm_bases":["PN-EN 12697-12:2018-08"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe Wrażliwość na działanie wody\nMetoda A PN-EN 12697-12:2018-08 Mieszanki mineralno-asfaltowe Wrazliwosc na dzialanie wody\nMetoda A PN-EN 12697-12:2018-08","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Water sensitivity","search_en":"Bituminous mixtures Water sensitivity Method A Technological Laboratory; Central Laboratory PN-EN 12697-12:2018-08","technique_en":"Method A","test_object_en":"Bituminous mixtures","search_zh":"沥青混合料 对水作用的敏感性 方法 A 工艺实验室；中央实验室 PN-EN 12697-12:2018-08","test_object_zh":"沥青混合料","lab_section_zh":"工艺实验室；中央实验室","technique_zh":"方法 A","methodology_zh":"对水作用的敏感性"},{"_id":"6a7d7a320636ba417e41b2b1","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe","methodology":"Odporność na deformacje pod obciążeniem","parameters":[],"technique":"Metoda B, mały aparat (w powietrzu)","techniques":["Metoda B, mały aparat (w powietrzu)"],"computed":[],"activity":"Odporność na deformacje pod obciążeniem\nMetoda B, mały aparat (w powietrzu)","reference":"PN-EN 12697-22:2020-07 | PN-EN 12697-22+A1:2024-05","norm_bases":["PN-EN 12697-22:2020-07","PN-EN 12697-22+A1:2024-05"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe Odporność na deformacje pod obciążeniem\nMetoda B, mały aparat (w powietrzu) PN-EN 12697-22:2020-07 | PN-EN 12697-22+A1:2024-05 Mieszanki mineralno-asfaltowe Odpornosc na deformacje pod obciazeniem\nMetoda B, maly aparat (w powietrzu) PN-EN 12697-22:2020-07 | PN-EN 12697-22+A1:2024-05","categories":["other"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Resistance to deformation under load","search_en":"Bituminous mixtures Resistance to deformation under load Method B, small device (in air) Technological Laboratory; Central Laboratory PN-EN 12697-22:2020-07 | PN-EN 12697-22+A1:2024-05","technique_en":"Method B, small device (in air)","test_object_en":"Bituminous mixtures","search_zh":"沥青混合料 工艺实验室；中央实验室 PN-EN 12697-22:2020-07 | PN-EN 12697-22+A1:2024-05","test_object_zh":"沥青混合料","lab_section_zh":"工艺实验室；中央实验室"},{"_id":"6a7d7a320636ba417e41b2b2","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe","methodology":"Spływność lepiszcza","parameters":[],"technique":"Metoda zlewki","techniques":["Metoda zlewki"],"computed":[],"activity":"Spływność lepiszcza\nMetoda zlewki","reference":"PN-EN 12697-18:2017-07","norm_bases":["PN-EN 12697-18:2017-07"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe Spływność lepiszcza\nMetoda zlewki PN-EN 12697-18:2017-07 Mieszanki mineralno-asfaltowe Splywnosc lepiszcza\nMetoda zlewki PN-EN 12697-18:2017-07","categories":["other"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Binder drainage","search_en":"Bituminous mixtures Binder drainage Beaker method Technological Laboratory; Central Laboratory PN-EN 12697-18:2017-07","technique_en":"Beaker method","test_object_en":"Bituminous mixtures","search_zh":"沥青混合料 胶结料析漏性 烧杯法 工艺实验室；中央实验室 PN-EN 12697-18:2017-07","test_object_zh":"沥青混合料","lab_section_zh":"工艺实验室；中央实验室","methodology_zh":"胶结料析漏性","technique_zh":"烧杯法"},{"_id":"6a7d7a320636ba417e41b2b3","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe","methodology":"Twardość (penetracja) na próbkach sześciennych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Twardość (penetracja) na próbkach sześciennych","reference":"PN-EN 12697-20:2020-07","norm_bases":["PN-EN 12697-20:2020-07"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe Twardość (penetracja) na próbkach sześciennych PN-EN 12697-20:2020-07 Mieszanki mineralno-asfaltowe Twardosc (penetracja) na probkach szesciennych PN-EN 12697-20:2020-07","categories":["other"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Hardness (penetration) on cube samples","search_en":"Bituminous mixtures Hardness (penetration) on cube samples Technological Laboratory; Central Laboratory PN-EN 12697-20:2020-07","test_object_en":"Bituminous mixtures","search_zh":"沥青混合料 立方体试样的硬度（针入度） 工艺实验室；中央实验室 PN-EN 12697-20:2020-07","test_object_zh":"沥青混合料","lab_section_zh":"工艺实验室；中央实验室","methodology_zh":"立方体试样的硬度（针入度）"},{"_id":"6a7d7a320636ba417e41b2b4","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe","methodology":"Zawartość wolnej przestrzeni (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wolnej przestrzeni (z obliczeń)","reference":"PN-EN 12697-8:2019-01","norm_bases":["PN-EN 12697-8:2019-01"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe Zawartość wolnej przestrzeni (z obliczeń) PN-EN 12697-8:2019-01 Mieszanki mineralno-asfaltowe Zawartosc wolnej przestrzeni (z obliczen) PN-EN 12697-8:2019-01","categories":["other"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Air void content (calculated)","search_en":"Bituminous mixtures Air void content (calculated) Technological Laboratory; Central Laboratory PN-EN 12697-8:2019-01","test_object_en":"Bituminous mixtures","search_zh":"沥青混合料 空隙率（计算值） 工艺实验室；中央实验室 PN-EN 12697-8:2019-01","test_object_zh":"沥青混合料","lab_section_zh":"工艺实验室；中央实验室","methodology_zh":"空隙率（计算值）"},{"_id":"6a7d7a320636ba417e41b2b5","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Mieszanki mineralno-asfaltowe","methodology":"Sczepność międzywarstwowa warstw asfaltowych","parameters":[],"technique":"Metoda Leutnera","techniques":["Metoda Leutnera"],"computed":[],"activity":"Sczepność międzywarstwowa warstw asfaltowych\nMetoda Leutnera","reference":"Instrukcja laboratoryjnego badania sczepności międzywarstwowej warstw asfaltowych wg metody Leutnera i wymagania techniczne sczepności, wyd. Politechnika Gdańska, 31.08.2014","norm_bases":["Instrukcja laboratoryjnego badania sczepności międzywarstwowej warstw asfaltowych wg metody Leutnera i wymagania techniczne sczepności, wyd. Politechnika Gdańska, 31.08.2014"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanki mineralno-asfaltowe Sczepność międzywarstwowa warstw asfaltowych\nMetoda Leutnera Instrukcja laboratoryjnego badania sczepności międzywarstwowej warstw asfaltowych wg metody Leutnera i wymagania techniczne sczepności, wyd. Politechnika Gdańska, 31.08.2014 Mieszanki mineralno-asfaltowe Sczepnosc miedzywarstwowa warstw asfaltowych\nMetoda Leutnera Instrukcja laboratoryjnego badania sczepnosci miedzywarstwowej warstw asfaltowych wg metody Leutnera i wymagania techniczne sczepnosci, wyd. Politechnika Gdanska, 31.08.2014","categories":["other"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Interlayer bond of asphalt layers","search_en":"Bituminous mixtures Interlayer bond of asphalt layers Leutner method Technological Laboratory; Central Laboratory Instrukcja laboratoryjnego badania sczepności międzywarstwowej warstw asfaltowych wg metody Leutnera i wymagania techniczne sczepności, wyd. Politechnika Gdańska, 31.08.2014","technique_en":"Leutner method","test_object_en":"Bituminous mixtures","search_zh":"沥青混合料 洛伊特纳法 工艺实验室；中央实验室 Instrukcja laboratoryjnego badania sczepności międzywarstwowej warstw asfaltowych wg metody Leutnera i wymagania techniczne sczepności, wyd. Politechnika Gdańska, 31.08.2014","test_object_zh":"沥青混合料","lab_section_zh":"工艺实验室；中央实验室","technique_zh":"洛伊特纳法"},{"_id":"6a7d7a320636ba417e41b2b6","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Asfalty i lepiszcza asfaltowe","methodology":"Temperatura mięknienia","parameters":[],"technique":"Metoda pierścienia i kuli","techniques":["Metoda pierścienia i kuli"],"computed":[],"activity":"Temperatura mięknienia\nMetoda pierścienia i kuli","reference":"PN-EN 1427:2015-08","norm_bases":["PN-EN 1427:2015-08"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Asfalty i lepiszcza asfaltowe Temperatura mięknienia\nMetoda pierścienia i kuli PN-EN 1427:2015-08 Asfalty i lepiszcza asfaltowe Temperatura mieknienia\nMetoda pierscienia i kuli PN-EN 1427:2015-08","categories":["other"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Softening point","search_en":"Bitumens and bituminous binders Softening point Ring and ball method Technological Laboratory; Central Laboratory PN-EN 1427:2015-08","technique_en":"Ring and ball method","test_object_en":"Bitumens and bituminous binders","lab_section_zh":"工艺实验室；中央实验室","search_zh":"沥青与沥青胶结料 软化点温度 环球法 工艺实验室；中央实验室 PN-EN 1427:2015-08","test_object_zh":"沥青与沥青胶结料","methodology_zh":"软化点温度","technique_zh":"环球法"},{"_id":"6a7d7a320636ba417e41b2b7","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Asfalty i lepiszcza asfaltowe","methodology":"Penetracja igłą","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Penetracja igłą","reference":"PN-EN 1426:2015-08 | PN-EN 1426:2025-02","norm_bases":["PN-EN 1426:2015-08","PN-EN 1426:2025-02"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Asfalty i lepiszcza asfaltowe Penetracja igłą PN-EN 1426:2015-08 | PN-EN 1426:2025-02 Asfalty i lepiszcza asfaltowe Penetracja igla PN-EN 1426:2015-08 | PN-EN 1426:2025-02","categories":["other"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Needle penetration","search_en":"Bitumens and bituminous binders Needle penetration Technological Laboratory; Central Laboratory PN-EN 1426:2015-08 | PN-EN 1426:2025-02","test_object_en":"Bitumens and bituminous binders","lab_section_zh":"工艺实验室；中央实验室","search_zh":"沥青与沥青胶结料 针入度 工艺实验室；中央实验室 PN-EN 1426:2015-08 | PN-EN 1426:2025-02","test_object_zh":"沥青与沥青胶结料","methodology_zh":"针入度"},{"_id":"6a7d7a320636ba417e41b2b8","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Grunty","methodology":"Uziarnienie","parameters":[],"technique":"Metoda przesiewania","techniques":["Metoda przesiewania"],"computed":[],"activity":"Uziarnienie\nMetoda przesiewania","reference":"PN-88/B-04481","norm_bases":["PN-88/B-04481"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Uziarnienie\nMetoda przesiewania PN-88/B-04481 Grunty Uziarnienie\nMetoda przesiewania PN-88/B-04481","categories":["other"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Grading","search_en":"Ground Grading Sieving method Technological Laboratory; Central Laboratory PN-88/B-04481","technique_en":"Sieving method","test_object_en":"Ground","search_zh":"土体 级配 筛分法 工艺实验室；中央实验室 PN-88/B-04481","test_object_zh":"土体","lab_section_zh":"工艺实验室；中央实验室","methodology_zh":"级配","technique_zh":"筛分法"},{"_id":"6a7d7a320636ba417e41b2b9","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Grunty","methodology":"Wilgotność optymalna, Maksymalna gęstość objętościowa szkieletu gruntowego","parameters":[],"technique":"Metoda Proctora","techniques":["Metoda Proctora"],"computed":[],"activity":"Wilgotność optymalna, Maksymalna gęstość objętościowa szkieletu gruntowego\nMetoda Proctora","reference":"PN-88/B-04481","norm_bases":["PN-88/B-04481"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Grunty Wilgotność optymalna, Maksymalna gęstość objętościowa szkieletu gruntowego\nMetoda Proctora PN-88/B-04481 Grunty Wilgotnosc optymalna, Maksymalna gestosc objetosciowa szkieletu gruntowego\nMetoda Proctora PN-88/B-04481","categories":["other"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Optimum moisture content, Maximum dry density of the soil skeleton","search_en":"Ground Optimum moisture content, Maximum dry density of the soil skeleton Proctor method Technological Laboratory; Central Laboratory PN-88/B-04481","technique_en":"Proctor method","test_object_en":"Ground","search_zh":"土体 最佳含水率、土骨架最大干密度 普氏击实法 工艺实验室；中央实验室 PN-88/B-04481","test_object_zh":"土体","lab_section_zh":"工艺实验室；中央实验室","technique_zh":"普氏击实法","methodology_zh":"最佳含水率、土骨架最大干密度"},{"_id":"6a7d7a320636ba417e41b2ba","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Podłoże","methodology":"Moduł odkształcenia, Zakres obciążenia: (0,02 – 0,35) MPa","parameters":[],"technique":"Metoda obciążeń płytą VSS","techniques":["Metoda obciążeń płytą VSS"],"computed":[],"activity":"Moduł odkształcenia, Zakres obciążenia: (0,02 – 0,35) MPa\nMetoda obciążeń płytą VSS","reference":"PN-S-02205:1998 Załącznik B","norm_bases":["PN-S-02205:1998 Załącznik B"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Podłoże Moduł odkształcenia, Zakres obciążenia: (0,02 – 0,35) MPa\nMetoda obciążeń płytą VSS PN-S-02205:1998 Załącznik B Podloze Modul odksztalcenia, Zakres obciazenia: (0,02 – 0,35) MPa\nMetoda obciazen plyta VSS PN-S-02205:1998 Zalacznik B","categories":["other"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Modulus of deformation, Load range: (0,02 – 0,35) MPa","search_en":"Growing medium Modulus of deformation, Load range: (0,02 – 0,35) MPa VSS plate loading method Technological Laboratory; Central Laboratory PN-S-02205:1998 Załącznik B","technique_en":"VSS plate loading method","test_object_en":"Growing medium","search_zh":"栽培基质 VSS 平板荷载法 工艺实验室；中央实验室 PN-S-02205:1998 Załącznik B","test_object_zh":"栽培基质","lab_section_zh":"工艺实验室；中央实验室","technique_zh":"VSS 平板荷载法"},{"_id":"6a7d7a320636ba417e41b2bb","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Warstwy konstrukcyjne nawierzchni","methodology":"Moduł odkształcenia, Zakres obciążenia: (0,02 – 0,45) MPa","parameters":[],"technique":"Metoda obciążeń płytą VSS","techniques":["Metoda obciążeń płytą VSS"],"computed":[],"activity":"Moduł odkształcenia, Zakres obciążenia: (0,02 – 0,45) MPa\nMetoda obciążeń płytą VSS","reference":"PN-S-02205:1998 Załącznik B","norm_bases":["PN-S-02205:1998 Załącznik B"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Warstwy konstrukcyjne nawierzchni Moduł odkształcenia, Zakres obciążenia: (0,02 – 0,45) MPa\nMetoda obciążeń płytą VSS PN-S-02205:1998 Załącznik B Warstwy konstrukcyjne nawierzchni Modul odksztalcenia, Zakres obciazenia: (0,02 – 0,45) MPa\nMetoda obciazen plyta VSS PN-S-02205:1998 Zalacznik B","categories":["other"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Modulus of deformation, Load range: (0,02 – 0,45) MPa","search_en":"Pavement structural layers Modulus of deformation, Load range: (0,02 – 0,45) MPa VSS plate loading method Technological Laboratory; Central Laboratory PN-S-02205:1998 Załącznik B","technique_en":"VSS plate loading method","test_object_en":"Pavement structural layers","lab_section_zh":"工艺实验室；中央实验室","search_zh":"路面结构层 VSS 平板荷载法 工艺实验室；中央实验室 PN-S-02205:1998 Załącznik B","test_object_zh":"路面结构层","technique_zh":"VSS 平板荷载法"},{"_id":"6a7d7a320636ba417e41b2bc","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Nawierzchnie drogowe","methodology":"Profile poprzeczne i podłużne (nierówności)","parameters":[{"name":"Zakres","range":"(0-20) cm"},{"name":"Międzynarodowy Wskaźnik Równości Podłużnej IRI (z obliczeń)"}],"technique":"Metoda: profilometryczna urządzenie typu inercyjnego - profilograf laserowy","techniques":["Metoda: profilometryczna urządzenie typu inercyjnego - profilograf laserowy"],"computed":[],"activity":"Profile poprzeczne i podłużne (nierówności)\nZakres:\nZakres (0-20) cm\nMiędzynarodowy Wskaźnik Równości Podłużnej IRI (z obliczeń)\nMetoda: profilometryczna urządzenie typu inercyjnego - profilograf laserowy","reference":"PN-EN 13036-6:2008 | Rozporządzenie Ministra Infrastruktury z dnia 01.08.2019 r. (Dz.U. 2019 poz.1643) WR-D-64 Wytyczne określania cech powierzchniowych nawierzchni jezdni i innych części dróg, wersja 01 z dnia 18.07.2022 p. 5 i 6","norm_bases":["PN-EN 13036-6:2008","Rozporządzenie Ministra Infrastruktury z dnia 01.08.2019 r. (Dz.U. 2019 poz.1643) WR-D-64 Wytyczne określania cech powierzchniowych nawierzchni jezdni i innych części dróg, wersja 01 z dnia 18.07.2022 p. 5 i 6"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawierzchnie drogowe Profile poprzeczne i podłużne (nierówności)\nZakres:\nZakres (0-20) cm\nMiędzynarodowy Wskaźnik Równości Podłużnej IRI (z obliczeń)\nMetoda: profilometryczna urządzenie typu inercyjnego - profilograf laserowy PN-EN 13036-6:2008 | Rozporządzenie Ministra Infrastruktury z dnia 01.08.2019 r. (Dz.U. 2019 poz.1643) WR-D-64 Wytyczne określania cech powierzchniowych nawierzchni jezdni i innych części dróg, wersja 01 z dnia 18.07.2022 p. 5 i 6 Nawierzchnie drogowe Profile poprzeczne i podluzne (nierownosci)\nZakres:\nZakres (0-20) cm\nMiedzynarodowy Wskaznik Rownosci Podluznej IRI (z obliczen)\nMetoda: profilometryczna urzadzenie typu inercyjnego - profilograf laserowy PN-EN 13036-6:2008 | Rozporzadzenie Ministra Infrastruktury z dnia 01.08.2019 r. (Dz.U. 2019 poz.1643) WR-D-64 Wytyczne okreslania cech powierzchniowych nawierzchni jezdni i innych czesci drog, wersja 01 z dnia 18.07.2022 p. 5 i 6","categories":["other"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Transverse and longitudinal profiles (unevenness)","parameters_en":[{"name":"Range","range":"(0-20) cm"},{"name":"International Roughness Index IRI (calculated)"}],"search_en":"Road pavements Transverse and longitudinal profiles (unevenness) Method: profilometric, inertial-type device - laser profilograph Technological Laboratory; Central Laboratory Range International Roughness Index IRI (calculated) PN-EN 13036-6:2008 | Rozporządzenie Ministra Infrastruktury z dnia 01.08.2019 r. (Dz.U. 2019 poz.1643) WR-D-64 Wytyczne określania cech powierzchniowych nawierzchni jezdni i innych części dróg, wersja 01 z dnia 18.07.2022 p. 5 i 6","technique_en":"Method: profilometric, inertial-type device - laser profilograph","test_object_en":"Road pavements","parameters_zh":[{"name":"范围","range":"(0-20) cm"},{"name":"国际平整度指数 IRI（由计算得出）"}],"search_zh":"路面 工艺实验室；中央实验室 范围 国际平整度指数 IRI（由计算得出） PN-EN 13036-6:2008 | Rozporządzenie Ministra Infrastruktury z dnia 01.08.2019 r. (Dz.U. 2019 poz.1643) WR-D-64 Wytyczne określania cech powierzchniowych nawierzchni jezdni i innych części dróg, wersja 01 z dnia 18.07.2022 p. 5 i 6","test_object_zh":"路面","lab_section_zh":"工艺实验室；中央实验室"},{"_id":"6a7d7a320636ba417e41b2bd","lab_id":"69ad52a3de79e566650fb8e5","country":"PL","accr_number":"AB 1689","accr_body":"PCA","test_object":"Nawierzchnie drogowe","methodology":"Średnia głębokość profilu","parameters":[],"technique":"Metoda: profilometryczna urządzenie typu inercyjnego - profilograf laserowy","techniques":["Metoda: profilometryczna urządzenie typu inercyjnego - profilograf laserowy"],"computed":[],"activity":"Średnia głębokość profilu\nMetoda: profilometryczna urządzenie typu inercyjnego - profilograf laserowy","reference":"PN-EN ISO 13473-1:2019-04 WR-D-64 Wytyczne określania cech powierzchniowych nawierzchni jezdni i innych części dróg, wersja 01 z dnia 18.07.2022 p. 4.3","norm_bases":["PN-EN ISO 13473-1:2019-04 WR-D-64 Wytyczne określania cech powierzchniowych nawierzchni jezdni i innych części dróg, wersja 01 z dnia 18.07.2022 p. 4.3"],"lab_section":"Laboratorium Technologiczne; Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawierzchnie drogowe Średnia głębokość profilu\nMetoda: profilometryczna urządzenie typu inercyjnego - profilograf laserowy PN-EN ISO 13473-1:2019-04 WR-D-64 Wytyczne określania cech powierzchniowych nawierzchni jezdni i innych części dróg, wersja 01 z dnia 18.07.2022 p. 4.3 Nawierzchnie drogowe Srednia glebokosc profilu\nMetoda: profilometryczna urzadzenie typu inercyjnego - profilograf laserowy PN-EN ISO 13473-1:2019-04 WR-D-64 Wytyczne okreslania cech powierzchniowych nawierzchni jezdni i innych czesci drog, wersja 01 z dnia 18.07.2022 p. 4.3","categories":["other"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Technological Laboratory; Central Laboratory","methodology_en":"Mean profile depth","search_en":"Road pavements Mean profile depth Method: profilometric, inertial-type device - laser profilograph Technological Laboratory; Central Laboratory PN-EN ISO 13473-1:2019-04 WR-D-64 Wytyczne określania cech powierzchniowych nawierzchni jezdni i innych części dróg, wersja 01 z dnia 18.07.2022 p. 4.3","technique_en":"Method: profilometric, inertial-type device - laser profilograph","test_object_en":"Road pavements","search_zh":"路面 工艺实验室；中央实验室 PN-EN ISO 13473-1:2019-04 WR-D-64 Wytyczne określania cech powierzchniowych nawierzchni jezdni i innych części dróg, wersja 01 z dnia 18.07.2022 p. 4.3","test_object_zh":"路面","lab_section_zh":"工艺实验室；中央实验室"}],"has_pdf":true}