{"lab":{"_id":"69ad52a3de79e566650fb8d7","accr_number":"AB 1679","country":"PL","accr_body":"PCA","address":"Zespół Kontroli Jakości, ul. Przemysłowa 64, 43-100 Tychy","categories":["petro","food","water"],"city":"Tychy","imported_at":"2026-03-08T10:42:43.265Z","methods_count":18,"name":"BIOAGRA-OIL S.A","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1679.pdf"],"scope_summary":"","search_text":"bioagra-oil s.a zespół kontroli jakości, ul. przemysłowa 64, 43-100 tychy petro water other automotive","status":"active","updated_at":"2026-03-08T14:50:48.659Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:02:44.290Z","email_confidence":"high","email_mx":true,"email_source":"https://www.gowork.pl/bioagra-oil-s.a.,471116/dane-kontaktowe-firmy","parse_date":"2026-08-13T08:02:44.290Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/10; C/22","pl":"Badania chemiczne paliw ciekłych, żywności","en":"Chemical tests of liquid fuels, food"},{"codes":"N/10","pl":"Badania właściwości fizycznych paliw ciekłych","en":"Tests of physical properties of liquid fuels"}],"issue":{"no":"8","date":"20.04.2026"},"map_coord":[50.105415,19.025695],"map_geo":"nominatim-street","lab_locations":[{"name":"Zespół Kontroli Jakości","address":"ul. Przemysłowa 64","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/7a59fbd7b1f0c0b93127f35f280a68f1/AB%201679.pdf","has_en":true,"category_counts":{"petro":18,"food":6,"water":2},"category_scores":{"petro":12.46,"food":1.38,"water":0.15},"has_zh":true},"methods":[{"_id":"6a7d7a240636ba417e41b1ef","lab_id":"69ad52a3de79e566650fb8d7","country":"PL","accr_number":"AB 1679","accr_body":"PCA","test_object":"Biopaliwa ciekłe: olej roślinny, Żywność: olej roślinny","methodology":"Liczba kwasowa","parameters":[{"name":"Zakres","range":"(0,10 – 4,0) mg KOH/g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba kwasowa\nZakres (0,10 – 4,0) mg KOH/g\nMetoda miareczkowa","reference":"PN-EN ISO 660:2021-03 z wyłączeniem pkt. 9.2 i 9.3","norm_bases":["PN-EN ISO 660:2021-03 z wyłączeniem pkt. 9.2 i 9.3"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biopaliwa ciekłe: olej roślinny, Żywność: olej roślinny Liczba kwasowa\nZakres (0,10 – 4,0) mg KOH/g\nMetoda miareczkowa PN-EN ISO 660:2021-03 z wyłączeniem pkt. 9.2 i 9.3 Biopaliwa ciekle: olej roslinny, Zywnosc: olej roslinny Liczba kwasowa\nZakres (0,10 – 4,0) mg KOH/g\nMetoda miareczkowa PN-EN ISO 660:2021-03 z wylaczeniem pkt. 9.2 i 9.3","categories":["petro","food"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acid value","parameters_en":[{"name":"Range","range":"(0,10 – 4,0) mg KOH/g"}],"search_en":"Liquid biofuels: vegetable oil, Food: vegetable oil Acid value Titrimetric method Range PN-EN ISO 660:2021-03 z wyłączeniem pkt. 9.2 i 9.3","technique_en":"Titrimetric method","test_object_en":"Liquid biofuels: vegetable oil, Food: vegetable oil","parameters_zh":[{"name":"范围","range":"(0,10 – 4,0) mg KOH/g"}],"search_zh":"液体生物燃料：植物油；食品：植物油 酸值 滴定法 范围 PN-EN ISO 660:2021-03 z wyłączeniem pkt. 9.2 i 9.3","technique_zh":"滴定法","methodology_zh":"酸值","test_object_zh":"液体生物燃料：植物油；食品：植物油"},{"_id":"6a7d7a240636ba417e41b1f0","lab_id":"69ad52a3de79e566650fb8d7","country":"PL","accr_number":"AB 1679","accr_body":"PCA","test_object":"Biopaliwa ciekłe: olej roślinny, Żywność: olej roślinny","methodology":"Zawartość wolnych kwasów tłuszczowych WKT (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wolnych kwasów tłuszczowych WKT (z obliczeń)","reference":"PN-EN ISO 660:2021-03 z wyłączeniem pkt. 9.2 i 9.3","norm_bases":["PN-EN ISO 660:2021-03 z wyłączeniem pkt. 9.2 i 9.3"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biopaliwa ciekłe: olej roślinny, Żywność: olej roślinny Zawartość wolnych kwasów tłuszczowych WKT (z obliczeń) PN-EN ISO 660:2021-03 z wyłączeniem pkt. 9.2 i 9.3 Biopaliwa ciekle: olej roslinny, Zywnosc: olej roslinny Zawartosc wolnych kwasow tluszczowych WKT (z obliczen) PN-EN ISO 660:2021-03 z wylaczeniem pkt. 9.2 i 9.3","categories":["petro","food"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of free fatty acids FFA (calculated)","search_en":"Liquid biofuels: vegetable oil, Food: vegetable oil Content of free fatty acids FFA (calculated) PN-EN ISO 660:2021-03 z wyłączeniem pkt. 9.2 i 9.3","test_object_en":"Liquid biofuels: vegetable oil, Food: vegetable oil","search_zh":"液体生物燃料：植物油；食品：植物油 PN-EN ISO 660:2021-03 z wyłączeniem pkt. 9.2 i 9.3","test_object_zh":"液体生物燃料：植物油；食品：植物油"},{"_id":"6a7d7a240636ba417e41b1f1","lab_id":"69ad52a3de79e566650fb8d7","country":"PL","accr_number":"AB 1679","accr_body":"PCA","test_object":"Biopaliwa ciekłe: olej roślinny, Żywność: olej roślinny","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,003 – 0,200) % (m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,003 – 0,200) % (m/m)\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005 +Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005 +Ap1:2021-11"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biopaliwa ciekłe: olej roślinny, Żywność: olej roślinny Zawartość wody\nZakres (0,003 – 0,200) % (m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005 +Ap1:2021-11 Biopaliwa ciekle: olej roslinny, Zywnosc: olej roslinny Zawartosc wody\nZakres (0,003 – 0,200) % (m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005 +Ap1:2021-11","categories":["petro","water","food"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,003 – 0,200) % (m/m)"}],"search_en":"Liquid biofuels: vegetable oil, Food: vegetable oil Water content Coulometric titration method Range PN-EN ISO 12937:2005 +Ap1:2021-11","technique_en":"Coulometric titration method","test_object_en":"Liquid biofuels: vegetable oil, Food: vegetable oil","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,003 – 0,200) % (m/m)"}],"search_zh":"液体生物燃料：植物油；食品：植物油 水分含量 库仑滴定法 范围 PN-EN ISO 12937:2005 +Ap1:2021-11","technique_zh":"库仑滴定法","test_object_zh":"液体生物燃料：植物油；食品：植物油"},{"_id":"6a7d7a240636ba417e41b1f2","lab_id":"69ad52a3de79e566650fb8d7","country":"PL","accr_number":"AB 1679","accr_body":"PCA","test_object":"Biopaliwa ciekłe: olej roślinny, Żywność: olej roślinny","methodology":"Liczba zmydlenia","parameters":[{"name":"Zakres","range":"(150,0 – 200,0) mg KOH / g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba zmydlenia\nZakres (150,0 – 200,0) mg KOH / g\nMetoda miareczkowa","reference":"PN-EN ISO 3657:2024-01","norm_bases":["PN-EN ISO 3657:2024-01"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biopaliwa ciekłe: olej roślinny, Żywność: olej roślinny Liczba zmydlenia\nZakres (150,0 – 200,0) mg KOH / g\nMetoda miareczkowa PN-EN ISO 3657:2024-01 Biopaliwa ciekle: olej roslinny, Zywnosc: olej roslinny Liczba zmydlenia\nZakres (150,0 – 200,0) mg KOH / g\nMetoda miareczkowa PN-EN ISO 3657:2024-01","categories":["petro","food"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Saponification value","parameters_en":[{"name":"Range","range":"(150,0 – 200,0) mg KOH / g"}],"search_en":"Liquid biofuels: vegetable oil, Food: vegetable oil Saponification value Titrimetric method Range PN-EN ISO 3657:2024-01","technique_en":"Titrimetric method","test_object_en":"Liquid biofuels: vegetable oil, Food: vegetable oil","parameters_zh":[{"name":"范围","range":"(150,0 – 200,0) mg KOH / g"}],"search_zh":"液体生物燃料：植物油；食品：植物油 皂化值 滴定法 范围 PN-EN ISO 3657:2024-01","technique_zh":"滴定法","test_object_zh":"液体生物燃料：植物油；食品：植物油","methodology_zh":"皂化值"},{"_id":"6a7d7a240636ba417e41b1f3","lab_id":"69ad52a3de79e566650fb8d7","country":"PL","accr_number":"AB 1679","accr_body":"PCA","test_object":"Biopaliwa ciekłe: olej roślinny, Żywność: olej roślinny","methodology":"Liczba nadtlenkowa","parameters":[{"name":"Zakres","range":"(0 – 15,0) meq O2/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba nadtlenkowa\nZakres (0 – 15,0) meq O2/kg\nMetoda miareczkowa","reference":"PN-EN ISO 3960:2017-03","norm_bases":["PN-EN ISO 3960:2017-03"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biopaliwa ciekłe: olej roślinny, Żywność: olej roślinny Liczba nadtlenkowa\nZakres (0 – 15,0) meq O2/kg\nMetoda miareczkowa PN-EN ISO 3960:2017-03 Biopaliwa ciekle: olej roslinny, Zywnosc: olej roslinny Liczba nadtlenkowa\nZakres (0 – 15,0) meq O2/kg\nMetoda miareczkowa PN-EN ISO 3960:2017-03","categories":["petro","food"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Peroxide value","parameters_en":[{"name":"Range","range":"(0 – 15,0) meq O2/kg"}],"search_en":"Liquid biofuels: vegetable oil, Food: vegetable oil Peroxide value Titrimetric method Range PN-EN ISO 3960:2017-03","technique_en":"Titrimetric method","test_object_en":"Liquid biofuels: vegetable oil, Food: vegetable oil","parameters_zh":[{"name":"范围","range":"(0 – 15,0) meq O2/kg"}],"search_zh":"液体生物燃料：植物油；食品：植物油 过氧化值 滴定法 范围 PN-EN ISO 3960:2017-03","technique_zh":"滴定法","methodology_zh":"过氧化值","test_object_zh":"液体生物燃料：植物油；食品：植物油"},{"_id":"6a7d7a240636ba417e41b1f4","lab_id":"69ad52a3de79e566650fb8d7","country":"PL","accr_number":"AB 1679","accr_body":"PCA","test_object":"Biopaliwa ciekłe: olej roślinny, Żywność: olej roślinny","methodology":"Skład kwasów tłuszczowych","parameters":[{"name":"Zakres","range":"(0,1 – 63,0)% (m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)"],"computed":[],"activity":"Skład kwasów tłuszczowych\nZakres (0,1 – 63,0)% (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)","reference":"PN-EN ISO 12966-1:2015-01 | PN-EN ISO 12966-2:2017-05 z wyłączeniem punktu 5.4 i 5.5 | PN-EN ISO 12966-4:2015-07","norm_bases":["PN-EN ISO 12966-1:2015-01","PN-EN ISO 12966-2:2017-05 z wyłączeniem punktu 5.4 i 5.5","PN-EN ISO 12966-4:2015-07"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biopaliwa ciekłe: olej roślinny, Żywność: olej roślinny Skład kwasów tłuszczowych\nZakres (0,1 – 63,0)% (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID) PN-EN ISO 12966-1:2015-01 | PN-EN ISO 12966-2:2017-05 z wyłączeniem punktu 5.4 i 5.5 | PN-EN ISO 12966-4:2015-07 Biopaliwa ciekle: olej roslinny, Zywnosc: olej roslinny Sklad kwasow tluszczowych\nZakres (0,1 – 63,0)% (m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo - jonizacyjna (GC-FID) PN-EN ISO 12966-1:2015-01 | PN-EN ISO 12966-2:2017-05 z wylaczeniem punktu 5.4 i 5.5 | PN-EN ISO 12966-4:2015-07","categories":["petro","food"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fatty acid composition","parameters_en":[{"name":"Range","range":"(0,1 – 63,0)% (m/m)"}],"search_en":"Liquid biofuels: vegetable oil, Food: vegetable oil Fatty acid composition Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 12966-1:2015-01 | PN-EN ISO 12966-2:2017-05 z wyłączeniem punktu 5.4 i 5.5 | PN-EN ISO 12966-4:2015-07","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Liquid biofuels: vegetable oil, Food: vegetable oil","parameters_zh":[{"name":"范围","range":"(0,1 – 63,0)% (m/m)"}],"search_zh":"液体生物燃料：植物油；食品：植物油 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-EN ISO 12966-1:2015-01 | PN-EN ISO 12966-2:2017-05 z wyłączeniem punktu 5.4 i 5.5 | PN-EN ISO 12966-4:2015-07","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"液体生物燃料：植物油；食品：植物油"},{"_id":"6a7d7a240636ba417e41b1f5","lab_id":"69ad52a3de79e566650fb8d7","country":"PL","accr_number":"AB 1679","accr_body":"PCA","test_object":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,010 – 0,050) % (m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"computed":[],"activity":"Zawartość wody\nZakres (0,010 – 0,050) % (m/m)\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1:2021-11","norm_bases":["PN-EN ISO 12937:2005+Ap1:2021-11"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość wody\nZakres (0,010 – 0,050) % (m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11 Biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc wody\nZakres (0,010 – 0,050) % (m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1:2021-11","categories":["water","petro"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,010 – 0,050) % (m/m)"}],"search_en":"Liquid biofuels: fatty acid methyl esters (FAME) Water content Coulometric titration method Range PN-EN ISO 12937:2005+Ap1:2021-11","technique_en":"Coulometric titration method","test_object_en":"Liquid biofuels: fatty acid methyl esters (FAME)","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,010 – 0,050) % (m/m)"}],"search_zh":"液体生物燃料：脂肪酸甲酯（FAME） 水分含量 库仑滴定法 范围 PN-EN ISO 12937:2005+Ap1:2021-11","technique_zh":"库仑滴定法","test_object_zh":"液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a7d7a240636ba417e41b1f6","lab_id":"69ad52a3de79e566650fb8d7","country":"PL","accr_number":"AB 1679","accr_body":"PCA","test_object":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura zablokowania zimnego filtru (CFPP)","parameters":[{"name":"Zakres","range":"(-25 – 0) oC"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtru (CFPP)\nZakres (-25 – 0) oC\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Temperatura zablokowania zimnego filtru (CFPP)\nZakres (-25 – 0) oC\nMetoda optyczna PN-EN 116:2015-09 Biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Temperatura zablokowania zimnego filtru (CFPP)\nZakres (-25 – 0) oC\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cold filter plugging point (CFPP)","parameters_en":[{"name":"Range","range":"(-25 – 0) oC"}],"search_en":"Liquid biofuels: fatty acid methyl esters (FAME) Cold filter plugging point (CFPP) Optical method Range PN-EN 116:2015-09","technique_en":"Optical method","test_object_en":"Liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(-25 – 0) oC"}],"search_zh":"液体生物燃料：脂肪酸甲酯（FAME） 冷滤点（CFPP） 光学法 范围 PN-EN 116:2015-09","technique_zh":"光学法","test_object_zh":"液体生物燃料：脂肪酸甲酯（FAME）","methodology_zh":"冷滤点（CFPP）"},{"_id":"6a7d7a240636ba417e41b1f7","lab_id":"69ad52a3de79e566650fb8d7","country":"PL","accr_number":"AB 1679","accr_body":"PCA","test_object":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość zanieczyszczeń","parameters":[{"name":"Zakres","range":"(5,0 – 27,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa","reference":"PN-EN 12662-2:2024-11","norm_bases":["PN-EN 12662-2:2024-11"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość zanieczyszczeń\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11 Biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc zanieczyszczen\nZakres (5,0 – 27,0) mg/kg\nMetoda wagowa PN-EN 12662-2:2024-11","categories":["petro"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Impurity content","parameters_en":[{"name":"Range","range":"(5,0 – 27,0) mg/kg"}],"search_en":"Liquid biofuels: fatty acid methyl esters (FAME) Impurity content Gravimetric method Range PN-EN 12662-2:2024-11","technique_en":"Gravimetric method","test_object_en":"Liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(5,0 – 27,0) mg/kg"}],"search_zh":"液体生物燃料：脂肪酸甲酯（FAME） 杂质含量 重量法 范围 PN-EN 12662-2:2024-11","technique_zh":"重量法","methodology_zh":"杂质含量","test_object_zh":"液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a7d7a240636ba417e41b1f8","lab_id":"69ad52a3de79e566650fb8d7","country":"PL","accr_number":"AB 1679","accr_body":"PCA","test_object":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Gęstość w temp. 15oC","parameters":[{"name":"Zakres","range":"(835,0 – 892,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość w temp. 15oC\nZakres (835,0 – 892,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Gęstość w temp. 15oC\nZakres (835,0 – 892,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Gestosc w temp. 15oC\nZakres (835,0 – 892,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density at temp. 15oC","parameters_en":[{"name":"Range","range":"(835,0 – 892,0) kg/m3"}],"search_en":"Liquid biofuels: fatty acid methyl esters (FAME) Density at temp. 15oC Oscillation method Range PN-EN ISO 12185:2024-08","technique_en":"Oscillation method","test_object_en":"Liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(835,0 – 892,0) kg/m3"}],"search_zh":"液体生物燃料：脂肪酸甲酯（FAME） 振荡法 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法","test_object_zh":"液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a7d7a240636ba417e41b1f9","lab_id":"69ad52a3de79e566650fb8d7","country":"PL","accr_number":"AB 1679","accr_body":"PCA","test_object":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Liczba kwasowa","parameters":[{"name":"Zakres","range":"(0,30 – 0,90) mg KOH/g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba kwasowa\nZakres (0,30 – 0,90) mg KOH/g\nMetoda miareczkowa","reference":"PN-EN 14104:2021-06","norm_bases":["PN-EN 14104:2021-06"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Liczba kwasowa\nZakres (0,30 – 0,90) mg KOH/g\nMetoda miareczkowa PN-EN 14104:2021-06 Biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Liczba kwasowa\nZakres (0,30 – 0,90) mg KOH/g\nMetoda miareczkowa PN-EN 14104:2021-06","categories":["petro"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acid value","parameters_en":[{"name":"Range","range":"(0,30 – 0,90) mg KOH/g"}],"search_en":"Liquid biofuels: fatty acid methyl esters (FAME) Acid value Titrimetric method Range PN-EN 14104:2021-06","technique_en":"Titrimetric method","test_object_en":"Liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(0,30 – 0,90) mg KOH/g"}],"search_zh":"液体生物燃料：脂肪酸甲酯（FAME） 酸值 滴定法 范围 PN-EN 14104:2021-06","technique_zh":"滴定法","methodology_zh":"酸值","test_object_zh":"液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a7d7a240636ba417e41b1fa","lab_id":"69ad52a3de79e566650fb8d7","country":"PL","accr_number":"AB 1679","accr_body":"PCA","test_object":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość estrów i estru metylowego kwasu linolenowego","parameters":[{"name":"Suma estrów"},{"name":"Zakres","range":"(94,0 – 99,0) % (m/m)"},{"name":"Ester metylowy kwasu linolenowego"},{"name":"Zakres","range":"(5,0 – 9,0) % (m/m)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość estrów i estru metylowego kwasu linolenowego\nZakres:\nSuma estrów\nZakres (94,0 – 99,0) % (m/m)\nEster metylowy kwasu linolenowego\nZakres (5,0 – 9,0) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID)","reference":"PN-EN 14103:2020-06","norm_bases":["PN-EN 14103:2020-06"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość estrów i estru metylowego kwasu linolenowego\nZakres:\nSuma estrów\nZakres (94,0 – 99,0) % (m/m)\nEster metylowy kwasu linolenowego\nZakres (5,0 – 9,0) % (m/m)\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC-FID) PN-EN 14103:2020-06 Biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc estrow i estru metylowego kwasu linolenowego\nZakres:\nSuma estrow\nZakres (94,0 – 99,0) % (m/m)\nEster metylowy kwasu linolenowego\nZakres (5,0 – 9,0) % (m/m)\nMetoda chromatografii gazowej z detekcja plomieniowo - jonizacyjna (GC-FID) PN-EN 14103:2020-06","categories":["petro"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of esters and linolenic acid methyl ester","parameters_en":[{"name":"Sum of esters"},{"name":"Range","range":"(94,0 – 99,0) % (m/m)"},{"name":"Linolenic acid methyl ester"},{"name":"Range","range":"(5,0 – 9,0) % (m/m)"}],"search_en":"Liquid biofuels: fatty acid methyl esters (FAME) Content of esters and linolenic acid methyl ester Gas chromatography with flame ionization detection (GC-FID) Sum of esters Range Linolenic acid methyl ester Range PN-EN 14103:2020-06","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"Suma estrów"},{"name":"范围","range":"(94,0 – 99,0) % (m/m)"},{"name":"Ester metylowy kwasu linolenowego"},{"name":"范围","range":"(5,0 – 9,0) % (m/m)"}],"search_zh":"液体生物燃料：脂肪酸甲酯（FAME） 酯类与亚麻酸甲酯含量 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PN-EN 14103:2020-06","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"液体生物燃料：脂肪酸甲酯（FAME）","methodology_zh":"酯类与亚麻酸甲酯含量"},{"_id":"6a7d7a240636ba417e41b1fb","lab_id":"69ad52a3de79e566650fb8d7","country":"PL","accr_number":"AB 1679","accr_body":"PCA","test_object":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość acylogliceroli, wolnego i ogólnego glicerolu","parameters":[{"name":"Monoacyloglicerole"},{"name":"Zakres","range":"(0,25 – 0,70) % (m/m)"},{"name":"Diacyloglicerole"},{"name":"Zakres","range":"(0,07 – 0,20) % (m/m)"},{"name":"Tricyloglicerole"},{"name":"Zakres","range":"(0,05 – 0,20) % (m/m)"},{"name":"Wolny glicerol"},{"name":"Zakres","range":"(0,002 – 0,200) % (m/m)"},{"name":"Ogólny glicerol (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość acylogliceroli, wolnego i ogólnego glicerolu\nZakres:\nMonoacyloglicerole\nZakres (0,25 – 0,70) % (m/m)\nDiacyloglicerole\nZakres (0,07 – 0,20) % (m/m)\nTricyloglicerole\nZakres (0,05 – 0,20) % (m/m)\nWolny glicerol\nZakres (0,002 – 0,200) % (m/m)\nOgólny glicerol (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 14105:2025-04","norm_bases":["PN-EN 14105:2025-04"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość acylogliceroli, wolnego i ogólnego glicerolu\nZakres:\nMonoacyloglicerole\nZakres (0,25 – 0,70) % (m/m)\nDiacyloglicerole\nZakres (0,07 – 0,20) % (m/m)\nTricyloglicerole\nZakres (0,05 – 0,20) % (m/m)\nWolny glicerol\nZakres (0,002 – 0,200) % (m/m)\nOgólny glicerol (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 14105:2025-04 Biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc acylogliceroli, wolnego i ogolnego glicerolu\nZakres:\nMonoacyloglicerole\nZakres (0,25 – 0,70) % (m/m)\nDiacyloglicerole\nZakres (0,07 – 0,20) % (m/m)\nTricyloglicerole\nZakres (0,05 – 0,20) % (m/m)\nWolny glicerol\nZakres (0,002 – 0,200) % (m/m)\nOgolny glicerol (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 14105:2025-04","categories":["petro"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of acylglycerols, free and total glycerol","parameters_en":[{"name":"Monoacylglycerols"},{"name":"Range","range":"(0,25 – 0,70) % (m/m)"},{"name":"Diacylglycerols"},{"name":"Range","range":"(0,07 – 0,20) % (m/m)"},{"name":"Triacylglycerols"},{"name":"Range","range":"(0,05 – 0,20) % (m/m)"},{"name":"Free glycerol"},{"name":"Range","range":"(0,002 – 0,200) % (m/m)"},{"name":"Total glycerol (calculated)"}],"search_en":"Liquid biofuels: fatty acid methyl esters (FAME) Content of acylglycerols, free and total glycerol Gas chromatography with flame ionization detection (GC-FID) Monoacylglycerols Range Diacylglycerols Range Triacylglycerols Range Free glycerol Range Total glycerol (calculated) PN-EN 14105:2025-04","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"Monoacyloglicerole"},{"name":"范围","range":"(0,25 – 0,70) % (m/m)"},{"name":"Diacyloglicerole"},{"name":"范围","range":"(0,07 – 0,20) % (m/m)"},{"name":"Tricyloglicerole"},{"name":"范围","range":"(0,05 – 0,20) % (m/m)"},{"name":"Wolny glicerol"},{"name":"范围","range":"(0,002 – 0,200) % (m/m)"},{"name":"总甘油（由计算得出）"}],"search_zh":"液体生物燃料：脂肪酸甲酯（FAME） 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 范围 总甘油（由计算得出） PN-EN 14105:2025-04","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a7d7a240636ba417e41b1fc","lab_id":"69ad52a3de79e566650fb8d7","country":"PL","accr_number":"AB 1679","accr_body":"PCA","test_object":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Zawartość metanolu","parameters":[{"name":"Zakres","range":"(0,02 – 0,50) % (m/m)"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"computed":[],"activity":"Zawartość metanolu\nZakres (0,02 – 0,50) % (m/m)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PN-EN 14110:2019-05","norm_bases":["PN-EN 14110:2019-05"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Zawartość metanolu\nZakres (0,02 – 0,50) % (m/m)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją płomieniowo-jonizacyjną (HS-GC-FID) PN-EN 14110:2019-05 Biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Zawartosc metanolu\nZakres (0,02 – 0,50) % (m/m)\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja plomieniowo-jonizacyjna (HS-GC-FID) PN-EN 14110:2019-05","categories":["petro"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Methanol content","parameters_en":[{"name":"Range","range":"(0,02 – 0,50) % (m/m)"}],"search_en":"Liquid biofuels: fatty acid methyl esters (FAME) Methanol content Headspace gas chromatography with flame ionization detection (HS-GC-FID) Range PN-EN 14110:2019-05","technique_en":"Headspace gas chromatography with flame ionization detection (HS-GC-FID)","test_object_en":"Liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(0,02 – 0,50) % (m/m)"}],"search_zh":"液体生物燃料：脂肪酸甲酯（FAME） 甲醇含量 顶空气相色谱-火焰离子化检测法（HS-GC-FID） 范围 PN-EN 14110:2019-05","technique_zh":"顶空气相色谱-火焰离子化检测法（HS-GC-FID）","methodology_zh":"甲醇含量","test_object_zh":"液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a7d7a240636ba417e41b1fd","lab_id":"69ad52a3de79e566650fb8d7","country":"PL","accr_number":"AB 1679","accr_body":"PCA","test_object":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Liczba jodowa","parameters":[{"name":"Zakres","range":"(105 – 129) g I2 / 100g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba jodowa\nZakres (105 – 129) g I2 / 100g\nMetoda miareczkowa","reference":"PN-EN 14111:2022-11","norm_bases":["PN-EN 14111:2022-11"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Liczba jodowa\nZakres (105 – 129) g I2 / 100g\nMetoda miareczkowa PN-EN 14111:2022-11 Biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Liczba jodowa\nZakres (105 – 129) g I2 / 100g\nMetoda miareczkowa PN-EN 14111:2022-11","categories":["petro"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iodine value","parameters_en":[{"name":"Range","range":"(105 – 129) g I2 / 100g"}],"search_en":"Liquid biofuels: fatty acid methyl esters (FAME) Iodine value Titrimetric method Range PN-EN 14111:2022-11","technique_en":"Titrimetric method","test_object_en":"Liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(105 – 129) g I2 / 100g"}],"search_zh":"液体生物燃料：脂肪酸甲酯（FAME） 碘值 滴定法 范围 PN-EN 14111:2022-11","technique_zh":"滴定法","methodology_zh":"碘值","test_object_zh":"液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a7d7a240636ba417e41b1fe","lab_id":"69ad52a3de79e566650fb8d7","country":"PL","accr_number":"AB 1679","accr_body":"PCA","test_object":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(4,0 – 16,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (4,0 – 16,0) h\nMetoda konduktometryczna","reference":"PN-EN 14112:2021-05","norm_bases":["PN-EN 14112:2021-05"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Stabilność oksydacyjna\nZakres (4,0 – 16,0) h\nMetoda konduktometryczna PN-EN 14112:2021-05 Biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Stabilnosc oksydacyjna\nZakres (4,0 – 16,0) h\nMetoda konduktometryczna PN-EN 14112:2021-05","categories":["petro"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation stability","parameters_en":[{"name":"Range","range":"(4,0 – 16,0) h"}],"search_en":"Liquid biofuels: fatty acid methyl esters (FAME) Oxidation stability Conductometric method Range PN-EN 14112:2021-05","technique_en":"Conductometric method","test_object_en":"Liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(4,0 – 16,0) h"}],"search_zh":"液体生物燃料：脂肪酸甲酯（FAME） 氧化安定性 电导法 范围 PN-EN 14112:2021-05","technique_zh":"电导法","methodology_zh":"氧化安定性","test_object_zh":"液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a7d7a240636ba417e41b1ff","lab_id":"69ad52a3de79e566650fb8d7","country":"PL","accr_number":"AB 1679","accr_body":"PCA","test_object":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Stabilność oksydacyjna","parameters":[{"name":"Zakres","range":"(4,0 – 16,0) h"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Stabilność oksydacyjna\nZakres (4,0 – 16,0) h\nMetoda konduktometryczna","reference":"PN-EN 15751:2014-05","norm_bases":["PN-EN 15751:2014-05"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Stabilność oksydacyjna\nZakres (4,0 – 16,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05 Biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Stabilnosc oksydacyjna\nZakres (4,0 – 16,0) h\nMetoda konduktometryczna PN-EN 15751:2014-05","categories":["petro"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation stability","parameters_en":[{"name":"Range","range":"(4,0 – 16,0) h"}],"search_en":"Liquid biofuels: fatty acid methyl esters (FAME) Oxidation stability Conductometric method Range PN-EN 15751:2014-05","technique_en":"Conductometric method","test_object_en":"Liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(4,0 – 16,0) h"}],"search_zh":"液体生物燃料：脂肪酸甲酯（FAME） 氧化安定性 电导法 范围 PN-EN 15751:2014-05","technique_zh":"电导法","methodology_zh":"氧化安定性","test_object_zh":"液体生物燃料：脂肪酸甲酯（FAME）"},{"_id":"6a7d7a240636ba417e41b200","lab_id":"69ad52a3de79e566650fb8d7","country":"PL","accr_number":"AB 1679","accr_body":"PCA","test_object":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME)","methodology":"Lepkość kinematyczna w temp. 40°C","parameters":[{"name":"Zakres","range":"(3,000 – 6,000) mm2/s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"computed":[],"activity":"Lepkość kinematyczna w temp. 40°C\nZakres (3,000 – 6,000) mm2/s\nMetoda kapilarna","reference":"PN-EN ISO 3104:2024-01","norm_bases":["PN-EN ISO 3104:2024-01"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biopaliwa ciekłe: estry metylowe kwasów tłuszczowych (FAME) Lepkość kinematyczna w temp. 40°C\nZakres (3,000 – 6,000) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01 Biopaliwa ciekle: estry metylowe kwasow tluszczowych (FAME) Lepkosc kinematyczna w temp. 40°C\nZakres (3,000 – 6,000) mm2/s\nMetoda kapilarna PN-EN ISO 3104:2024-01","categories":["petro"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kinematic viscosity at 40°C","parameters_en":[{"name":"Range","range":"(3,000 – 6,000) mm2/s"}],"search_en":"Liquid biofuels: fatty acid methyl esters (FAME) Kinematic viscosity at 40°C Capillary method Range PN-EN ISO 3104:2024-01","technique_en":"Capillary method","test_object_en":"Liquid biofuels: fatty acid methyl esters (FAME)","parameters_zh":[{"name":"范围","range":"(3,000 – 6,000) mm2/s"}],"search_zh":"液体生物燃料：脂肪酸甲酯（FAME） 40°C 时的运动黏度 毛细管法 范围 PN-EN ISO 3104:2024-01","technique_zh":"毛细管法","test_object_zh":"液体生物燃料：脂肪酸甲酯（FAME）","methodology_zh":"40°C 时的运动黏度"}],"has_pdf":true}