{"lab":{"_id":"69ad52a3de79e566650fb8cb","accr_number":"AB 1671","country":"PL","accr_body":"PCA","address":"ul. Warszawska 153, 43-300 Bielsko-Biała, CENTRUM BADAŃ I INNOWACJI, ul. Dojazdowa 5","categories":["other"],"city":"Bielsko-Biała","imported_at":"2026-03-08T10:42:43.265Z","methods_count":10,"name":"ALUPROF S.A.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1671.pdf"],"scope_summary":"","search_text":"aluprof s.a. ul. warszawska 153, 43-300 bielsko-biała, centrum badań i innowacji, ul. dojazdowa 5 other","status":"active","updated_at":"2026-03-08T14:50:48.300Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:48.300Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201671,podmiot.html","parse_date":"2026-07-17T16:19:17.703Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"N/5","pl":"Badania właściwości fizycznych wyrobów budowlanych","en":"Tests of physical properties of building products"}],"issue":{"no":"9","date":"13.02.2026"},"map_coord":[49.842336,19.034234],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":10},"category_scores":{"other":10},"has_zh":true},"methods":[{"_id":"6a5a56059af9f73f38254cf2","lab_id":"69ad52a3de79e566650fb8cb","country":"PL","accr_number":"AB 1671","accr_body":"PCA","test_object":"Okna","test_object_en":"Windows","methodology":"Siły operacyjne Zakres: (1 - 200) N (0,3 - 30) Nm","methodology_en":"Operating forces Range: (1 - 200) N (0,3 - 30) Nm","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siły operacyjne Zakres: (1 - 200) N (0,3 - 30) Nm","reference":"PN-EN 12046-1:2021","norm_bases":["PN-EN 12046-1:2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna Siły operacyjne Zakres: (1 - 200) N (0,3 - 30) Nm PN-EN 12046-1:2021 Okna Sily operacyjne Zakres: (1 - 200) N (0,3 - 30) Nm PN-EN 12046-1:2021","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows Operating forces Range: (1 - 200) N (0,3 - 30) Nm PN-EN 12046-1:2021","search_zh":"窗 PN-EN 12046-1:2021","test_object_zh":"窗"},{"_id":"6a5a56059af9f73f38254cf3","lab_id":"69ad52a3de79e566650fb8cb","country":"PL","accr_number":"AB 1671","accr_body":"PCA","test_object":"Drzwi","test_object_en":"Doors","methodology":"Siły operacyjne Zakres: (1 - 200) N (0,3 - 30) Nm Pomiar dynamicznej siły zamykającej metodą z obciążnikami","methodology_en":"Operating forces Range: (1 - 200) N (0,3 - 30) Nm Measurement of dynamic closing force by the weights method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Siły operacyjne Zakres: (1 - 200) N (0,3 - 30) Nm Pomiar dynamicznej siły zamykającej metodą z obciążnikami","reference":"PN-EN 12046-2:2025-09","norm_bases":["PN-EN 12046-2:2025-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drzwi Siły operacyjne Zakres: (1 - 200) N (0,3 - 30) Nm Pomiar dynamicznej siły zamykającej metodą z obciążnikami PN-EN 12046-2:2025-09 Drzwi Sily operacyjne Zakres: (1 - 200) N (0,3 - 30) Nm Pomiar dynamicznej sily zamykajacej metoda z obciaznikami PN-EN 12046-2:2025-09","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Doors Operating forces Range: (1 - 200) N (0,3 - 30) Nm Measurement of dynamic closing force by the weights method PN-EN 12046-2:2025-09","search_zh":"门 PN-EN 12046-2:2025-09","test_object_zh":"门"},{"_id":"6a5a56059af9f73f38254cf4","lab_id":"69ad52a3de79e566650fb8cb","country":"PL","accr_number":"AB 1671","accr_body":"PCA","test_object":"Okna i drzwi zewnętrzne Wymiary obiektów Szerokość: do 6000 mm Wysokość: do 6500 mm","test_object_en":"Windows and external doors Object dimensions Width: up to 6000 mm Height: up to 6500 mm","methodology":"Wodoszczelność Zakres: (0 - 7500) Pa","methodology_en":"Watertightness Range: (0 - 7500) Pa","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność Zakres: (0 - 7500) Pa","reference":"PN-EN 1027:2016-04","norm_bases":["PN-EN 1027:2016-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna i drzwi zewnętrzne Wymiary obiektów Szerokość: do 6000 mm Wysokość: do 6500 mm Wodoszczelność Zakres: (0 - 7500) Pa PN-EN 1027:2016-04 Okna i drzwi zewnetrzne Wymiary obiektow Szerokosc: do 6000 mm Wysokosc: do 6500 mm Wodoszczelnosc Zakres: (0 - 7500) Pa PN-EN 1027:2016-04","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows and external doors Object dimensions Width: up to 6000 mm Height: up to 6500 mm Watertightness Range: (0 - 7500) Pa PN-EN 1027:2016-04","search_zh":"窗与外门 对象尺寸 宽度：至 6000 mm 高度：至 6500 mm PN-EN 1027:2016-04","test_object_zh":"窗与外门 对象尺寸 宽度：至 6000 mm 高度：至 6500 mm"},{"_id":"6a5a56059af9f73f38254cf5","lab_id":"69ad52a3de79e566650fb8cb","country":"PL","accr_number":"AB 1671","accr_body":"PCA","test_object":"Okna i drzwi zewnętrzne Wymiary obiektów Szerokość: do 6000 mm Wysokość: do 6500 mm","test_object_en":"Windows and external doors Object dimensions Width: up to 6000 mm Height: up to 6500 mm","methodology":"Przepuszczalność powietrza Zakres: (0,6 - 500) m3/h","methodology_en":"Air permeability Range: (0,6 - 500) m3/h","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza Zakres: (0,6 - 500) m3/h","reference":"PN-EN 1026:2016-04","norm_bases":["PN-EN 1026:2016-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna i drzwi zewnętrzne Wymiary obiektów Szerokość: do 6000 mm Wysokość: do 6500 mm Przepuszczalność powietrza Zakres: (0,6 - 500) m3/h PN-EN 1026:2016-04 Okna i drzwi zewnetrzne Wymiary obiektow Szerokosc: do 6000 mm Wysokosc: do 6500 mm Przepuszczalnosc powietrza Zakres: (0,6 - 500) m3/h PN-EN 1026:2016-04","categories":["other"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows and external doors Object dimensions Width: up to 6000 mm Height: up to 6500 mm Air permeability Range: (0,6 - 500) m3/h PN-EN 1026:2016-04","search_zh":"窗与外门 对象尺寸 宽度：至 6000 mm 高度：至 6500 mm PN-EN 1026:2016-04","test_object_zh":"窗与外门 对象尺寸 宽度：至 6000 mm 高度：至 6500 mm"},{"_id":"6a5a56059af9f73f38254cf6","lab_id":"69ad52a3de79e566650fb8cb","country":"PL","accr_number":"AB 1671","accr_body":"PCA","test_object":"Okna i drzwi zewnętrzne Wymiary obiektów Szerokość: do 6000 mm Wysokość: do 6500 mm","test_object_en":"Windows and external doors Object dimensions Width: up to 6000 mm Height: up to 6500 mm","methodology":"Odporność na obciążenie wiatrem Zakres: ((-7500) - 7500) Pa","methodology_en":"Resistance to wind load Range: ((-7500) - 7500) Pa","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie wiatrem Zakres: ((-7500) - 7500) Pa","reference":"PN-EN 12211:2016-04","norm_bases":["PN-EN 12211:2016-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna i drzwi zewnętrzne Wymiary obiektów Szerokość: do 6000 mm Wysokość: do 6500 mm Odporność na obciążenie wiatrem Zakres: ((-7500) - 7500) Pa PN-EN 12211:2016-04 Okna i drzwi zewnetrzne Wymiary obiektow Szerokosc: do 6000 mm Wysokosc: do 6500 mm Odpornosc na obciazenie wiatrem Zakres: ((-7500) - 7500) Pa PN-EN 12211:2016-04","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows and external doors Object dimensions Width: up to 6000 mm Height: up to 6500 mm Resistance to wind load Range: ((-7500) - 7500) Pa PN-EN 12211:2016-04","search_zh":"窗与外门 对象尺寸 宽度：至 6000 mm 高度：至 6500 mm PN-EN 12211:2016-04","test_object_zh":"窗与外门 对象尺寸 宽度：至 6000 mm 高度：至 6500 mm"},{"_id":"6a5a56059af9f73f38254cf7","lab_id":"69ad52a3de79e566650fb8cb","country":"PL","accr_number":"AB 1671","accr_body":"PCA","test_object":"Ściany osłonowe Wymiary obiektów Szerokość: do 6000 mm Wysokość: do 6500 mm","test_object_en":"Curtain walling Object dimensions Width: up to 6000 mm Height: up to 6500 mm","methodology":"Wodoszczelność Zakres: (0 - 7500) Pa","methodology_en":"Watertightness Range: (0 - 7500) Pa","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wodoszczelność Zakres: (0 - 7500) Pa","reference":"PN-EN 12155:2004","norm_bases":["PN-EN 12155:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany osłonowe Wymiary obiektów Szerokość: do 6000 mm Wysokość: do 6500 mm Wodoszczelność Zakres: (0 - 7500) Pa PN-EN 12155:2004 Sciany oslonowe Wymiary obiektow Szerokosc: do 6000 mm Wysokosc: do 6500 mm Wodoszczelnosc Zakres: (0 - 7500) Pa PN-EN 12155:2004","categories":["other"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Curtain walling Object dimensions Width: up to 6000 mm Height: up to 6500 mm Watertightness Range: (0 - 7500) Pa PN-EN 12155:2004","search_zh":"幕墙 对象尺寸 宽度：至 6000 mm 高度：至 6500 mm PN-EN 12155:2004","test_object_zh":"幕墙 对象尺寸 宽度：至 6000 mm 高度：至 6500 mm"},{"_id":"6a5a56059af9f73f38254cf8","lab_id":"69ad52a3de79e566650fb8cb","country":"PL","accr_number":"AB 1671","accr_body":"PCA","test_object":"Ściany osłonowe Wymiary obiektów Szerokość: do 6000 mm Wysokość: do 6500 mm","test_object_en":"Curtain walling Object dimensions Width: up to 6000 mm Height: up to 6500 mm","methodology":"Przepuszczalność powietrza Zakres: (0,6 - 500) m3/h","methodology_en":"Air permeability Range: (0,6 - 500) m3/h","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przepuszczalność powietrza Zakres: (0,6 - 500) m3/h","reference":"PN-EN 12153:2024-01","norm_bases":["PN-EN 12153:2024-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany osłonowe Wymiary obiektów Szerokość: do 6000 mm Wysokość: do 6500 mm Przepuszczalność powietrza Zakres: (0,6 - 500) m3/h PN-EN 12153:2024-01 Sciany oslonowe Wymiary obiektow Szerokosc: do 6000 mm Wysokosc: do 6500 mm Przepuszczalnosc powietrza Zakres: (0,6 - 500) m3/h PN-EN 12153:2024-01","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Curtain walling Object dimensions Width: up to 6000 mm Height: up to 6500 mm Air permeability Range: (0,6 - 500) m3/h PN-EN 12153:2024-01","search_zh":"幕墙 对象尺寸 宽度：至 6000 mm 高度：至 6500 mm PN-EN 12153:2024-01","test_object_zh":"幕墙 对象尺寸 宽度：至 6000 mm 高度：至 6500 mm"},{"_id":"6a5a56059af9f73f38254cf9","lab_id":"69ad52a3de79e566650fb8cb","country":"PL","accr_number":"AB 1671","accr_body":"PCA","test_object":"Ściany osłonowe Wymiary obiektów Szerokość: do 6000 mm Wysokość: do 6500 mm","test_object_en":"Curtain walling Object dimensions Width: up to 6000 mm Height: up to 6500 mm","methodology":"Odporność na obciążenie wiatrem Zakres: ((-7500) - 7500) Pa","methodology_en":"Resistance to wind load Range: ((-7500) - 7500) Pa","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie wiatrem Zakres: ((-7500) - 7500) Pa","reference":"PN-EN 12179:2004","norm_bases":["PN-EN 12179:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ściany osłonowe Wymiary obiektów Szerokość: do 6000 mm Wysokość: do 6500 mm Odporność na obciążenie wiatrem Zakres: ((-7500) - 7500) Pa PN-EN 12179:2004 Sciany oslonowe Wymiary obiektow Szerokosc: do 6000 mm Wysokosc: do 6500 mm Odpornosc na obciazenie wiatrem Zakres: ((-7500) - 7500) Pa PN-EN 12179:2004","categories":["other"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Curtain walling Object dimensions Width: up to 6000 mm Height: up to 6500 mm Resistance to wind load Range: ((-7500) - 7500) Pa PN-EN 12179:2004","search_zh":"幕墙 对象尺寸 宽度：至 6000 mm 高度：至 6500 mm PN-EN 12179:2004","test_object_zh":"幕墙 对象尺寸 宽度：至 6000 mm 高度：至 6500 mm"},{"_id":"6a5a56059af9f73f38254cfa","lab_id":"69ad52a3de79e566650fb8cb","country":"PL","accr_number":"AB 1671","accr_body":"PCA","test_object":"Żaluzje zwijane, okiennice rozwierane, okiennice przesuwne, okiennice składane, okiennice harmonijkowe, okiennice harmonijkowe płaskozamykające się Wymiary obiektów Szerokość: do 6000 mm Wysokość: do 6500 mm","test_object_en":"Roller shutters, side-hung shutters, sliding shutters, folding shutters, concertina shutters, flat-closing concertina shutters Object dimensions Width: up to 6000 mm Height: up to 6500 mm","methodology":"Odporność na obciążenie wiatrem Zakres: ((-7500) - 7500) Pa Metoda z użyciem urządzenia pneumatycznego","methodology_en":"Resistance to wind load Range: ((-7500) - 7500) Pa Method using a pneumatic device","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na obciążenie wiatrem Zakres: ((-7500) - 7500) Pa Metoda z użyciem urządzenia pneumatycznego","reference":"PN-EN 1932:2013-09","norm_bases":["PN-EN 1932:2013-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Żaluzje zwijane, okiennice rozwierane, okiennice przesuwne, okiennice składane, okiennice harmonijkowe, okiennice harmonijkowe płaskozamykające się Wymiary obiektów Szerokość: do 6000 mm Wysokość: do 6500 mm Odporność na obciążenie wiatrem Zakres: ((-7500) - 7500) Pa Metoda z użyciem urządzenia pneumatycznego PN-EN 1932:2013-09 Zaluzje zwijane, okiennice rozwierane, okiennice przesuwne, okiennice skladane, okiennice harmonijkowe, okiennice harmonijkowe plaskozamykajace sie Wymiary obiektow Szerokosc: do 6000 mm Wysokosc: do 6500 mm Odpornosc na obciazenie wiatrem Zakres: ((-7500) - 7500) Pa Metoda z uzyciem urzadzenia pneumatycznego PN-EN 1932:2013-09","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Roller shutters, side-hung shutters, sliding shutters, folding shutters, concertina shutters, flat-closing concertina shutters Object dimensions Width: up to 6000 mm Height: up to 6500 mm Resistance to wind load Range: ((-7500) - 7500) Pa Method using a pneumatic device PN-EN 1932:2013-09"},{"_id":"6a5a56059af9f73f38254cfb","lab_id":"69ad52a3de79e566650fb8cb","country":"PL","accr_number":"AB 1671","accr_body":"PCA","test_object":"Okna Wymiary obiektów Szerokość: do 6000 mm Wysokość: do 6500 mm","test_object_en":"Windows Dimensions of items Width: up to 6000 mm Height: up to 6500 mm","methodology":"Odporność na uderzenie ciałem miękkim i ciężkim","methodology_en":"Resistance to soft and heavy body impact","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na uderzenie ciałem miękkim i ciężkim","reference":"PN-EN 13049:2024-03","norm_bases":["PN-EN 13049:2024-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okna Wymiary obiektów Szerokość: do 6000 mm Wysokość: do 6500 mm Odporność na uderzenie ciałem miękkim i ciężkim PN-EN 13049:2024-03 Okna Wymiary obiektow Szerokosc: do 6000 mm Wysokosc: do 6500 mm Odpornosc na uderzenie cialem miekkim i ciezkim PN-EN 13049:2024-03","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Windows Dimensions of items Width: up to 6000 mm Height: up to 6500 mm Resistance to soft and heavy body impact PN-EN 13049:2024-03","methodology_zh":"软体与硬重物撞击抗力","search_zh":"软体与硬重物撞击抗力 PN-EN 13049:2024-03"}],"has_pdf":true}